{"lab":{"_id":"6af574790ecd48de0c70624d","accr_number":"AP 108","country":"PL","imported_at":"2026-11-11T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Skrudlak 1, 34-600 Limanowa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"09.09.2019","city":"Limanowa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units.","cycle_from":"08.09.2023","cycle_to":"23.09.2027","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"7.15","pl":"elektryczna symulacja wielkości","en":"electric quantity simulation","de":"elektrische Simulation von Größen","zh":"量值的电模拟","cs":"elektrická simulace veličin"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.02","pl":"temperatura (termometria nieelektryczna)","en":"temperature (non-electrical thermometry)","de":"Temperatur (nichtelektrische Thermometrie)","zh":"温度（非电测温）","cs":"teplota (neelektrická termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"16","date":"16.06.2025"},"issue_date":"16.06.2025","issue_number":"16","lab_division":"Laboratorium Pomiarowe","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[20.4017608,49.7289727]},"map_coord":[49.7289727,20.4017608],"map_geo":"nominatim-street","methods_count":14,"name":"Limatherm Sensor Sp. z o.o.","parse_date":"2026-11-11T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-11T12:00:00.000Z","pdf_files":["AP_108.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: elektryczna symulacja wielkości, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"limatherm sensor sp. z o.o. laboratorium pomiarowe ul. skrudlak 1, 34-600 limanowa laboratorium wzorcujące. wielkości mierzone: elektryczna symulacja wielkości, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna). w stałej lokalizacji (s) i/lub poza nią (p). ap 108 ap108 laboratorium wzorcujące wzorcowanie kalibracja electric quantity simulation temperature (electrical thermometry) temperature (non-electrical thermometry) limatherm sensor sp. z o.o. laboratorium pomiarowe ul. skrudlak 1, 34-600 limanowa laboratorium wzorcujace. wielkosci mierzone: elektryczna symulacja wielkosci, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna). w stalej lokalizacji (s) i/lub poza nia (p). ap 108 ap108 laboratorium wzorcujace wzorcowanie kalibracja electric quantity simulation temperature (electrical thermometry) temperature (non-electrical thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20108,podmiot.html","source_pdf_sha256":"629e182d45c57bfa751699a206fc63ea9b8dd2e70932eac63bb8aab7a0d46c2b","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/11/00f8a4e2b5718637f6cfb02dafbc5ebb/AP%20108.pdf","status":"active","updated_at":"2026-11-11T12:00:00.000Z","valid_from":"24-09-2007","valid_until":"23-09-2027","website":"www.limathermsensor.pl","lab_division_en":"Measurement Laboratory","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 % und wird in Einheiten der Messgröße angegeben.","has_de":true,"lab_division_de":"Messlabor","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度，以被测量的单位表示。","lab_division_zh":"测量实验室","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota s pravděpodobností pokrytí přibližně 95 % a je vyjádřena v jednotkách měřené veličiny.","has_cs":true,"lab_division_cs":"Měřicí laboratoř","pelny_cs":true},"methods":[{"_id":"f0fb475b55985e3f2d013525","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Przetworniki temperatury","test_object_en":"Temperature transmitters","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"typ: R, S, B","range":"0 °C do 1760 °C","cmc":"0,55 °C"},{"name":"typ: J, K, N, T, E","range":"-200 °C do 1370 °C","cmc":"0,25 °C"},{"name":"typ: RTD","range":"-200 °C do 0 °C","cmc":"0,03 °C"},{"name":"typ: RTD","range":"0 °C do 850 °C","cmc":"0,07 °C"}],"parameters_en":[{"name":"type: R, S, B","range":"0 °C to 1760 °C","cmc":"0,55 °C"},{"name":"type: J, K, N, T, E","range":"-200 °C to 1370 °C","cmc":"0,25 °C"},{"name":"type: RTD","range":"-200 °C to 0 °C","cmc":"0,03 °C"},{"name":"type: RTD","range":"0 °C to 850 °C","cmc":"0,07 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\ntyp: R, S, B 0 °C do 1760 °C CMC 0,55 °C\ntyp: J, K, N, T, E -200 °C do 1370 °C CMC 0,25 °C\ntyp: RTD -200 °C do 0 °C CMC 0,03 °C\ntyp: RTD 0 °C do 850 °C CMC 0,07 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0","norm_bases":["PPL-09","PPLW-01","EURAMET cg -11 v.2.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Przetworniki temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\ntyp: R, S, B 0 °C do 1760 °C CMC 0,55 °C\ntyp: J, K, N, T, E -200 °C do 1370 °C CMC 0,25 °C\ntyp: RTD -200 °C do 0 °C CMC 0,03 °C\ntyp: RTD 0 °C do 850 °C CMC 0,07 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0 Przetworniki temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\ntyp: R, S, B 0 °C do 1760 °C CMC 0,55 °C\ntyp: J, K, N, T, E -200 °C do 1370 °C CMC 0,25 °C\ntyp: RTD -200 °C do 0 °C CMC 0,03 °C\ntyp: RTD 0 °C do 850 °C CMC 0,07 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0","search_en":"Temperature transmitters Calibration — Electric quantity simulation Internal procedure; At permanent location (S) and outside of it (P) Electric quantity simulation Internal procedure At permanent location (S) and outside of it (P) type: R, S, B type: J, K, N, T, E type: RTD type: RTD PPL-09, PPLW-01 based on EURAMET cg -11 v.2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PPL-09, PPLW-01 based on EURAMET cg -11 v.2.0","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"Typ: R, S, B","range":"0 °C to 1760 °C","cmc":"0,55 °C"},{"name":"Typ: J, K, N, T, E","range":"-200 °C bis 1370 °C","cmc":"0,25 °C"},{"name":"Typ: RTD","range":"-200 °C to 0 °C","cmc":"0,03 °C"},{"name":"Typ: RTD","range":"0 °C to 850 °C","cmc":"0,07 °C"}],"reference_de":"PPL-09, PPLW-01 auf Grundlage von EURAMET cg -11 v.2.0","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturmessumformer Kalibrierung — Elektrische Simulation von Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Elektrische Simulation von Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Typ: R, S, B Typ: J, K, N, T, E Typ: RTD Typ: RTD PPL-09, PPLW-01 auf Grundlage von EURAMET cg -11 v.2.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturmessumformer","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"型式：R, S, B","range":"0 °C to 1760 °C","cmc":"0,55 °C"},{"name":"型式：J, K, N, T, E","range":"-200 °C 至 1370 °C","cmc":"0,25 °C"},{"name":"型式：RTD","range":"-200 °C to 0 °C","cmc":"0,03 °C"},{"name":"型式：RTD","range":"0 °C to 850 °C","cmc":"0,07 °C"}],"reference_zh":"PPL-09, PPLW-01，依据 EURAMET cg -11 v.2.0","regulatory_area_zh":"量值的电模拟","search_zh":"温度变送器 校准 — 物理量的电模拟 内部程序；在固定地点 (S) 及固定地点以外 (P) 量值的电模拟 内部程序 在固定地点 (S) 及固定地点以外 (P) 型式：R, S, B 型式：J, K, N, T, E 型式：RTD 型式：RTD PPL-09, PPLW-01，依据 EURAMET cg -11 v.2.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温度变送器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"typ: R, S, B","range":"0 °C to 1760 °C","cmc":"0,55 °C"},{"name":"typ: J, K, N, T, E","range":"-200 °C do 1370 °C","cmc":"0,25 °C"},{"name":"typ: RTD","range":"-200 °C to 0 °C","cmc":"0,03 °C"},{"name":"typ: RTD","range":"0 °C to 850 °C","cmc":"0,07 °C"}],"reference_cs":"PPL-09, PPLW-01 na základě EURAMET cg -11 v.2.0","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Převodníky teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Elektrická simulace veličin Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) typ: R, S, B typ: J, K, N, T, E typ: RTD typ: RTD PPL-09, PPLW-01 na základě EURAMET cg -11 v.2.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Převodníky teploty"},{"_id":"9325f51f86b84bfdcecbcd6f","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Symulatory temperatury","test_object_en":"Temperature simulators","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"typ: R, S, B","range":"-30 °C do 0 °C","cmc":"0,6 °C"},{"name":"typ: R, S, B","range":"0 °C do 1820 °C","cmc":"0,5 °C"},{"name":"typ: J, K, N, T, E","range":"-270 °C do 1370 °C","cmc":"0,3 °C"},{"name":"typ: RTD","range":"-200 °C do 200 °C","cmc":"0,03 °C"},{"name":"typ: RTD","range":"200 °C do 850 °C","cmc":"0,05 °C"}],"parameters_en":[{"name":"type: R, S, B","range":"-30 °C to 0 °C","cmc":"0,6 °C"},{"name":"type: R, S, B","range":"0 °C to 1820 °C","cmc":"0,5 °C"},{"name":"type: J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,3 °C"},{"name":"type: RTD","range":"-200 °C to 200 °C","cmc":"0,03 °C"},{"name":"type: RTD","range":"200 °C to 850 °C","cmc":"0,05 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\ntyp: R, S, B -30 °C do 0 °C CMC 0,6 °C\ntyp: R, S, B 0 °C do 1820 °C CMC 0,5 °C\ntyp: J, K, N, T, E -270 °C do 1370 °C CMC 0,3 °C\ntyp: RTD -200 °C do 200 °C CMC 0,03 °C\ntyp: RTD 200 °C do 850 °C CMC 0,05 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0","norm_bases":["PPL-09","PPLW-01","EURAMET cg -11 v.2.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Symulatory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\ntyp: R, S, B -30 °C do 0 °C CMC 0,6 °C\ntyp: R, S, B 0 °C do 1820 °C CMC 0,5 °C\ntyp: J, K, N, T, E -270 °C do 1370 °C CMC 0,3 °C\ntyp: RTD -200 °C do 200 °C CMC 0,03 °C\ntyp: RTD 200 °C do 850 °C CMC 0,05 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0 Symulatory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\ntyp: R, S, B -30 °C do 0 °C CMC 0,6 °C\ntyp: R, S, B 0 °C do 1820 °C CMC 0,5 °C\ntyp: J, K, N, T, E -270 °C do 1370 °C CMC 0,3 °C\ntyp: RTD -200 °C do 200 °C CMC 0,03 °C\ntyp: RTD 200 °C do 850 °C CMC 0,05 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0","search_en":"Temperature simulators Calibration — Electric quantity simulation Internal procedure; At permanent location (S) and outside of it (P) Electric quantity simulation Internal procedure At permanent location (S) and outside of it (P) type: R, S, B type: R, S, B type: J, K, N, T, E type: RTD type: RTD PPL-09, PPLW-01 based on EURAMET cg -11 v.2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PPL-09, PPLW-01 based on EURAMET cg -11 v.2.0","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"Typ: R, S, B","range":"-30 °C to 0 °C","cmc":"0,6 °C"},{"name":"Typ: R, S, B","range":"0 °C to 1820 °C","cmc":"0,5 °C"},{"name":"Typ: J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,3 °C"},{"name":"Typ: RTD","range":"-200 °C to 200 °C","cmc":"0,03 °C"},{"name":"Typ: RTD","range":"200 °C to 850 °C","cmc":"0,05 °C"}],"reference_de":"PPL-09, PPLW-01 auf Grundlage von EURAMET cg -11 v.2.0","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperatursimulatoren Kalibrierung — Elektrische Simulation von Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Elektrische Simulation von Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Typ: R, S, B Typ: R, S, B Typ: J, K, N, T, E Typ: RTD Typ: RTD PPL-09, PPLW-01 auf Grundlage von EURAMET cg -11 v.2.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperatursimulatoren","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"型式：R, S, B","range":"-30 °C to 0 °C","cmc":"0,6 °C"},{"name":"型式：R, S, B","range":"0 °C to 1820 °C","cmc":"0,5 °C"},{"name":"型式：J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,3 °C"},{"name":"型式：RTD","range":"-200 °C to 200 °C","cmc":"0,03 °C"},{"name":"型式：RTD","range":"200 °C to 850 °C","cmc":"0,05 °C"}],"reference_zh":"PPL-09, PPLW-01，依据 EURAMET cg -11 v.2.0","regulatory_area_zh":"量值的电模拟","search_zh":"温度模拟器 校准 — 物理量的电模拟 内部程序；在固定地点 (S) 及固定地点以外 (P) 量值的电模拟 内部程序 在固定地点 (S) 及固定地点以外 (P) 型式：R, S, B 型式：R, S, B 型式：J, K, N, T, E 型式：RTD 型式：RTD PPL-09, PPLW-01，依据 EURAMET cg -11 v.2.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温度模拟器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"typ: R, S, B","range":"-30 °C to 0 °C","cmc":"0,6 °C"},{"name":"typ: R, S, B","range":"0 °C to 1820 °C","cmc":"0,5 °C"},{"name":"typ: J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,3 °C"},{"name":"typ: RTD","range":"-200 °C to 200 °C","cmc":"0,03 °C"},{"name":"typ: RTD","range":"200 °C to 850 °C","cmc":"0,05 °C"}],"reference_cs":"PPL-09, PPLW-01 na základě EURAMET cg -11 v.2.0","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Simulátory teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Elektrická simulace veličin Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) typ: R, S, B typ: R, S, B typ: J, K, N, T, E typ: RTD typ: RTD PPL-09, PPLW-01 na základě EURAMET cg -11 v.2.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Simulátory teploty"},{"_id":"0252c261a9e840b5b28536dc","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury","test_object_en":"Temperature indicators (meters) (including temperature controllers)\nTemperature recorders","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"typ: R, S, B","range":"-30 °C do 0 °C","cmc":"0,7 °C"},{"name":"typ: R, S, B","range":"0 °C do 1820 °C","cmc":"0,4 °C"},{"name":"typ: J, K, N, T, E","range":"-270 °C do 1370 °C","cmc":"0,35 °C"},{"name":"typ: RTD","range":"-200 °C do 200 °C","cmc":"0,05 °C"},{"name":"typ: RTD","range":"200 °C do 850 °C","cmc":"0,07 °C"}],"parameters_en":[{"name":"type: R, S, B","range":"-30 °C to 0 °C","cmc":"0,7 °C"},{"name":"type: R, S, B","range":"0 °C to 1820 °C","cmc":"0,4 °C"},{"name":"type: J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,35 °C"},{"name":"type: RTD","range":"-200 °C to 200 °C","cmc":"0,05 °C"},{"name":"type: RTD","range":"200 °C to 850 °C","cmc":"0,07 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\ntyp: R, S, B -30 °C do 0 °C CMC 0,7 °C\ntyp: R, S, B 0 °C do 1820 °C CMC 0,4 °C\ntyp: J, K, N, T, E -270 °C do 1370 °C CMC 0,35 °C\ntyp: RTD -200 °C do 200 °C CMC 0,05 °C\ntyp: RTD 200 °C do 850 °C CMC 0,07 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0","norm_bases":["PPL-09","PPLW-01","EURAMET cg -11 v.2.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\ntyp: R, S, B -30 °C do 0 °C CMC 0,7 °C\ntyp: R, S, B 0 °C do 1820 °C CMC 0,4 °C\ntyp: J, K, N, T, E -270 °C do 1370 °C CMC 0,35 °C\ntyp: RTD -200 °C do 200 °C CMC 0,05 °C\ntyp: RTD 200 °C do 850 °C CMC 0,07 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0 Wskazniki (mierniki) temperatury (w tym regulatory temperatury)\nRejestratory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\ntyp: R, S, B -30 °C do 0 °C CMC 0,7 °C\ntyp: R, S, B 0 °C do 1820 °C CMC 0,4 °C\ntyp: J, K, N, T, E -270 °C do 1370 °C CMC 0,35 °C\ntyp: RTD -200 °C do 200 °C CMC 0,05 °C\ntyp: RTD 200 °C do 850 °C CMC 0,07 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PPL-09, PPLW-01 w oparciu o EURAMET cg -11 v.2.0","search_en":"Temperature indicators (meters) (including temperature controllers) Temperature recorders Calibration — Electric quantity simulation Internal procedure; At permanent location (S) and outside of it (P) Electric quantity simulation Internal procedure At permanent location (S) and outside of it (P) type: R, S, B type: R, S, B type: J, K, N, T, E type: RTD type: RTD PPL-09, PPLW-01 based on EURAMET cg -11 v.2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PPL-09, PPLW-01 based on EURAMET cg -11 v.2.0","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"Typ: R, S, B","range":"-30 °C to 0 °C","cmc":"0,7 °C"},{"name":"Typ: R, S, B","range":"0 °C to 1820 °C","cmc":"0,4 °C"},{"name":"Typ: J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,35 °C"},{"name":"Typ: RTD","range":"-200 °C to 200 °C","cmc":"0,05 °C"},{"name":"Typ: RTD","range":"200 °C to 850 °C","cmc":"0,07 °C"}],"reference_de":"PPL-09, PPLW-01 auf Grundlage von EURAMET cg -11 v.2.0","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) (einschließlich Temperaturregler) Temperaturschreiber Kalibrierung — Elektrische Simulation von Größen Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Elektrische Simulation von Größen Internes Verfahren Am festen Standort (S) und außerhalb (P) Typ: R, S, B Typ: R, S, B Typ: J, K, N, T, E Typ: RTD Typ: RTD PPL-09, PPLW-01 auf Grundlage von EURAMET cg -11 v.2.0","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturanzeiger (-messgeräte) (einschließlich Temperaturregler)\nTemperaturschreiber","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"型式：R, S, B","range":"-30 °C to 0 °C","cmc":"0,7 °C"},{"name":"型式：R, S, B","range":"0 °C to 1820 °C","cmc":"0,4 °C"},{"name":"型式：J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,35 °C"},{"name":"型式：RTD","range":"-200 °C to 200 °C","cmc":"0,05 °C"},{"name":"型式：RTD","range":"200 °C to 850 °C","cmc":"0,07 °C"}],"reference_zh":"PPL-09, PPLW-01，依据 EURAMET cg -11 v.2.0","regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（表）（包括温度控制器） 温度记录仪 校准 — 物理量的电模拟 内部程序；在固定地点 (S) 及固定地点以外 (P) 量值的电模拟 内部程序 在固定地点 (S) 及固定地点以外 (P) 型式：R, S, B 型式：R, S, B 型式：J, K, N, T, E 型式：RTD 型式：RTD PPL-09, PPLW-01，依据 EURAMET cg -11 v.2.0","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温度指示仪（表）（包括温度控制器）\n温度记录仪","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"typ: R, S, B","range":"-30 °C to 0 °C","cmc":"0,7 °C"},{"name":"typ: R, S, B","range":"0 °C to 1820 °C","cmc":"0,4 °C"},{"name":"typ: J, K, N, T, E","range":"-270 °C to 1370 °C","cmc":"0,35 °C"},{"name":"typ: RTD","range":"-200 °C to 200 °C","cmc":"0,05 °C"},{"name":"typ: RTD","range":"200 °C to 850 °C","cmc":"0,07 °C"}],"reference_cs":"PPL-09, PPLW-01 na základě EURAMET cg -11 v.2.0","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřidla) teploty (včetně regulátorů teploty) Záznamníky teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Elektrická simulace veličin Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) typ: R, S, B typ: R, S, B typ: J, K, N, T, E typ: RTD typ: RTD PPL-09, PPLW-01 na základě EURAMET cg -11 v.2.0","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Ukazatele (měřidla) teploty (včetně regulátorů teploty)\nZáznamníky teploty"},{"_id":"3c777683f845c180d0339dd3","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych i nieszlachetnych","test_object_en":"Noble and base metal thermocouples","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"parameters_en":[{"name":"","range":"-30 °C do 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C to 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 250 °C CMC 0,4 °C\n250 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PPL-01","norm_bases":["PPL-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych i nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 250 °C CMC 0,4 °C\n250 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PPL-01 Czujniki termoelektryczne z metali szlachetnych i nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 250 °C CMC 0,4 °C\n250 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PPL-01","search_en":"Noble and base metal thermocouples Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) PPL-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C do 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C bis 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Thermoelemente aus Edelmetallen und unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PPL-01","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Thermoelemente aus Edelmetallen und unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C do 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C 至 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"贵金属和贱金属热电偶 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PPL-01","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"贵金属和贱金属热电偶","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C do 250 °C","cmc":"0,4 °C"},{"name":"","range":"250 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termočlánky z ušlechtilých a obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PPL-01","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Termočlánky z ušlechtilých a obecných kovů"},{"_id":"5b93912e7c911af4b3756e76","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych i nieszlachetnych","test_object_en":"Noble and base metal thermocouples","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-30 °C do 250 °C","cmc":"0,6 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C do 1000 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,6 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 250 °C CMC 0,6 °C\n250 °C do 500 °C CMC 0,7 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PPL-01, PPLW-01","norm_bases":["PPL-01","PPLW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych i nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 250 °C CMC 0,6 °C\n250 °C do 500 °C CMC 0,7 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PPL-01, PPLW-01 Czujniki termoelektryczne z metali szlachetnych i nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-30 °C do 250 °C CMC 0,6 °C\n250 °C do 500 °C CMC 0,7 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) PPL-01, PPLW-01","search_en":"Noble and base metal thermocouples Calibration — Temperature (electrical thermometry) Internal procedure; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Outside of permanent location (P) PPL-01, PPLW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,6 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Thermoelemente aus Edelmetallen und unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Außerhalb des festen Standorts (P) PPL-01, PPLW-01","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Thermoelemente aus Edelmetallen und unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,6 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"贵金属和贱金属热电偶 校准 — 温度（电测温） 内部程序；固定地点以外 (P) 温度（电测温） 内部程序 固定地点以外 (P) PPL-01, PPLW-01","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"贵金属和贱金属热电偶","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-30 °C to 250 °C","cmc":"0,6 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,7 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termočlánky z ušlechtilých a obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Mimo stálé pracoviště (P) Teplota (elektrická termometrie) Vnitřní postup Mimo stálou lokalitu (P) PPL-01, PPLW-01","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Termočlánky z ušlechtilých a obecných kovů"},{"_id":"92961e252b0e7849cfab9dc3","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C do 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,18 °C"}],"parameters_en":[{"name":"","range":"-50 °C to -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,18 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do -30 °C CMC 0,08 °C\n-30 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,04 °C\n250 °C do 500 °C CMC 0,18 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PPL-03","norm_bases":["PPL-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do -30 °C CMC 0,08 °C\n-30 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,04 °C\n250 °C do 500 °C CMC 0,18 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PPL-03 Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do -30 °C CMC 0,08 °C\n-30 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,04 °C\n250 °C do 500 °C CMC 0,18 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PPL-03","search_en":"Resistance thermometer sensors Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) PPL-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,18 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PPL-03","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C to -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,18 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PPL-03","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C to 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C to 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,18 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PPL-03","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"e66ecfeee1367cd8538e14cc","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C do 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,22 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,10 °C\n150 °C do 250 °C CMC 0,15 °C\n250 °C do 500 °C CMC 0,22 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PPL-03","norm_bases":["PPL-03"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,10 °C\n150 °C do 250 °C CMC 0,15 °C\n250 °C do 500 °C CMC 0,22 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PPL-03 Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,10 °C\n150 °C do 250 °C CMC 0,15 °C\n250 °C do 500 °C CMC 0,22 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) PPL-03","search_en":"Resistance thermometer sensors Calibration — Temperature (electrical thermometry) Internal procedure; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Outside of permanent location (P) PPL-03","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Außerhalb des festen Standorts (P) PPL-03","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；固定地点以外 (P) 温度（电测温） 内部程序 固定地点以外 (P) PPL-03","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Mimo stálé pracoviště (P) Teplota (elektrická termometrie) Vnitřní postup Mimo stálou lokalitu (P) PPL-03","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"2a5e2a8f9abcc405ebf0ccc3","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Przetworniki temperatury (zawierające czujniki temperatury)","test_object_en":"Temperature transmitters (containing temperature sensors)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 250 °C","cmc":"0,10 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,20 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"parameters_en":[{"name":"","range":"-50 °C do 250 °C","cmc":"0,10 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,20 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C to 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 250 °C CMC 0,10 °C\n250 °C do 500 °C CMC 0,20 °C\n500 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PPL-05","norm_bases":["PPL-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przetworniki temperatury (zawierające czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 250 °C CMC 0,10 °C\n250 °C do 500 °C CMC 0,20 °C\n500 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PPL-05 Przetworniki temperatury (zawierajace czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 250 °C CMC 0,10 °C\n250 °C do 500 °C CMC 0,20 °C\n500 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PPL-05","search_en":"Temperature transmitters (containing temperature sensors) Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) PPL-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C do 250 °C","cmc":"0,10 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,20 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C bis 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturmessumformer (mit Temperaturfühlern) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PPL-05","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturmessumformer (mit Temperaturfühlern)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C do 250 °C","cmc":"0,10 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,20 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C 至 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"温度变送器（含温度传感器） 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PPL-05","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"温度变送器（含温度传感器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C do 250 °C","cmc":"0,10 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,20 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Převodníky teploty (obsahující teplotní čidla) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PPL-05","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Převodníky teploty (obsahující teplotní čidla)"},{"_id":"1d1b00c0b0ef6cbfebb96b4a","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Przetworniki temperatury (zawierające czujniki temperatury)","test_object_en":"Temperature transmitters (containing temperature sensors)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 150 °C","cmc":"0,15 °C"},{"name":"","range":"150 °C do 250 °C","cmc":"0,20 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,25 °C"},{"name":"","range":"500 °C do 1000 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,15 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,20 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,25 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,15 °C\n150 °C do 250 °C CMC 0,20 °C\n250 °C do 500 °C CMC 0,25 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PPL-05, PPLW-01","norm_bases":["PPL-05","PPLW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Przetworniki temperatury (zawierające czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,15 °C\n150 °C do 250 °C CMC 0,20 °C\n250 °C do 500 °C CMC 0,25 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PPL-05, PPLW-01 Przetworniki temperatury (zawierajace czujniki temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,15 °C\n150 °C do 250 °C CMC 0,20 °C\n250 °C do 500 °C CMC 0,25 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) PPL-05, PPLW-01","search_en":"Temperature transmitters (containing temperature sensors) Calibration — Temperature (electrical thermometry) Internal procedure; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Outside of permanent location (P) PPL-05, PPLW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,15 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,20 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,25 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturmessumformer (mit Temperaturfühlern) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Außerhalb des festen Standorts (P) PPL-05, PPLW-01","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperaturmessumformer (mit Temperaturfühlern)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,15 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,20 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,25 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"温度变送器（含温度传感器） 校准 — 温度（电测温） 内部程序；固定地点以外 (P) 温度（电测温） 内部程序 固定地点以外 (P) PPL-05, PPLW-01","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"温度变送器（含温度传感器）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,15 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,20 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,25 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Převodníky teploty (obsahující teplotní čidla) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Mimo stálé pracoviště (P) Teplota (elektrická termometrie) Vnitřní postup Mimo stálou lokalitu (P) PPL-05, PPLW-01","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Převodníky teploty (obsahující teplotní čidla)"},{"_id":"06a1d13df9320f8465a8d161","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Kalibratory temperatury","test_object_en":"Temperature calibrators","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C do 400 °C","cmc":"1,2 °C"},{"name":"","range":"400 °C do 1000 °C","cmc":"2,5 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C to 400 °C","cmc":"1,2 °C"},{"name":"","range":"400 °C to 1000 °C","cmc":"2,5 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,5 °C\n150 °C do 400 °C CMC 1,2 °C\n400 °C do 1000 °C CMC 2,5 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PPL-07","norm_bases":["PPL-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,5 °C\n150 °C do 400 °C CMC 1,2 °C\n400 °C do 1000 °C CMC 2,5 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PPL-07 Kalibratory temperatury Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,5 °C\n150 °C do 400 °C CMC 1,2 °C\n400 °C do 1000 °C CMC 2,5 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PPL-07","search_en":"Temperature calibrators Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) PPL-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C to 400 °C","cmc":"1,2 °C"},{"name":"","range":"400 °C to 1000 °C","cmc":"2,5 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Temperaturkalibratoren Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PPL-07","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturkalibratoren","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C to 400 °C","cmc":"1,2 °C"},{"name":"","range":"400 °C to 1000 °C","cmc":"2,5 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"温度校准器 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PPL-07","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"温度校准器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,5 °C"},{"name":"","range":"150 °C to 400 °C","cmc":"1,2 °C"},{"name":"","range":"400 °C to 1000 °C","cmc":"2,5 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Kalibrátory teploty Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PPL-07","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Kalibrátory teploty"},{"_id":"bb58ea45a3aec5513b59c325","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C do 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,18 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"parameters_en":[{"name":"","range":"-50 °C do -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C do 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,18 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C to 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C to 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do -30 °C CMC 0,08 °C\n-30 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,04 °C\n250 °C do 500 °C CMC 0,18 °C\n500 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PPL-04","norm_bases":["PPL-04"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do -30 °C CMC 0,08 °C\n-30 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,04 °C\n250 °C do 500 °C CMC 0,18 °C\n500 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PPL-04 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do -30 °C CMC 0,08 °C\n-30 °C do 100 °C CMC 0,02 °C\n100 °C do 250 °C CMC 0,04 °C\n250 °C do 500 °C CMC 0,18 °C\n500 °C do 1085 °C CMC 0,7 °C\n1085 °C do 1200 °C CMC 1,0 °C\n1200 °C do 1300 °C CMC 1,4 °C\n1300 °C do 1500 °C CMC 1,9 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PPL-04","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; At permanent location (S) Temperature (electrical thermometry) Internal procedure At permanent location (S) PPL-04","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C do -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C do 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,18 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C bis 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C bis 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PPL-04","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C do -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C do 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,18 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C 至 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C 至 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PPL-04","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C do -30 °C","cmc":"0,08 °C"},{"name":"","range":"-30 °C do 100 °C","cmc":"0,02 °C"},{"name":"","range":"100 °C do 250 °C","cmc":"0,04 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,18 °C"},{"name":"","range":"500 °C do 1085 °C","cmc":"0,7 °C"},{"name":"","range":"1085 °C do 1200 °C","cmc":"1,0 °C"},{"name":"","range":"1200 °C do 1300 °C","cmc":"1,4 °C"},{"name":"","range":"1300 °C do 1500 °C","cmc":"1,9 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PPL-04","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"b99f50263a3e3702a79dc056","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury)","test_object_en":"Electrical thermometers (including electronic)\nElectrical thermometers (with temperature recording)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C do 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C do 500 °C","cmc":"0,22 °C"},{"name":"","range":"500 °C do 1000 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,10 °C\n150 °C do 250 °C CMC 0,15 °C\n250 °C do 500 °C CMC 0,22 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PPL-04, PPLW-01","norm_bases":["PPL-04","PPLW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracją temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,10 °C\n150 °C do 250 °C CMC 0,15 °C\n250 °C do 500 °C CMC 0,22 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PPL-04, PPLW-01 Termometry elektryczne (w tym elektroniczne)\nTermometry elektryczne (z rejestracja temperatury) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-50 °C do 150 °C CMC 0,10 °C\n150 °C do 250 °C CMC 0,15 °C\n250 °C do 500 °C CMC 0,22 °C\n500 °C do 1000 °C CMC 0,9 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) PPL-04, PPLW-01","search_en":"Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) Calibration — Temperature (electrical thermometry) Internal procedure; Outside of permanent location (P) Temperature (electrical thermometry) Internal procedure Outside of permanent location (P) PPL-04, PPLW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Elektrische Thermometer (mit Temperaturaufzeichnung) Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Temperatur (elektrische Thermometrie) Internes Verfahren Außerhalb des festen Standorts (P) PPL-04, PPLW-01","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)\nElektrische Thermometer (mit Temperaturaufzeichnung)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 电测温度计（带温度记录） 校准 — 温度（电测温） 内部程序；固定地点以外 (P) 温度（电测温） 内部程序 固定地点以外 (P) PPL-04, PPLW-01","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"电测温度计（包括电子温度计）\n电测温度计（带温度记录）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to 150 °C","cmc":"0,10 °C"},{"name":"","range":"150 °C to 250 °C","cmc":"0,15 °C"},{"name":"","range":"250 °C to 500 °C","cmc":"0,22 °C"},{"name":"","range":"500 °C to 1000 °C","cmc":"0,9 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Elektrické teploměry (se záznamem teploty) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Mimo stálé pracoviště (P) Teplota (elektrická termometrie) Vnitřní postup Mimo stálou lokalitu (P) PPL-04, PPLW-01","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)\nElektrické teploměry (se záznamem teploty)"},{"_id":"064ff34f1b8a4643433dcf45","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Termometry wskazówkowe bimetalowe\nTermometry wskazówkowe manometryczne\nTermometry wskazówkowe dylatacyjne","test_object_en":"Bimetallic dial thermometers\nPressure-spring dial thermometers\nExpansion dial thermometers","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 50 °C","cmc":"0,4 °C"},{"name":"","range":"50 °C do 400 °C","cmc":"1,0 °C"},{"name":"","range":"400 °C do 600 °C","cmc":"2,0 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,4 °C"},{"name":"","range":"50 °C to 400 °C","cmc":"1,0 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"2,0 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do 50 °C CMC 0,4 °C\n50 °C do 400 °C CMC 1,0 °C\n400 °C do 600 °C CMC 2,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PPL-06","norm_bases":["PPL-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry wskazówkowe bimetalowe\nTermometry wskazówkowe manometryczne\nTermometry wskazówkowe dylatacyjne Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do 50 °C CMC 0,4 °C\n50 °C do 400 °C CMC 1,0 °C\n400 °C do 600 °C CMC 2,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PPL-06 Termometry wskazowkowe bimetalowe\nTermometry wskazowkowe manometryczne\nTermometry wskazowkowe dylatacyjne Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do 50 °C CMC 0,4 °C\n50 °C do 400 °C CMC 1,0 °C\n400 °C do 600 °C CMC 2,0 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PPL-06","search_en":"Bimetallic dial thermometers Pressure-spring dial thermometers Expansion dial thermometers Calibration — Temperature (non-electrical thermometry) Internal procedure; At permanent location (S) Temperature (non-electrical thermometry) Internal procedure At permanent location (S) PPL-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,4 °C"},{"name":"","range":"50 °C to 400 °C","cmc":"1,0 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"2,0 °C"}],"regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Bimetall-Zeigerthermometer Manometrische Zeigerthermometer Ausdehnungs-Zeigerthermometer Kalibrierung — Temperatur (nichtelektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Am festen Standort (S) PPL-06","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Bimetall-Zeigerthermometer\nManometrische Zeigerthermometer\nAusdehnungs-Zeigerthermometer","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,4 °C"},{"name":"","range":"50 °C to 400 °C","cmc":"1,0 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"2,0 °C"}],"regulatory_area_zh":"温度（非电测温）","search_zh":"双金属指针式温度计 压力式指针温度计 膨胀式指针温度计 校准 — 温度（非电测温） 内部程序；在固定地点 (S) 温度（非电测温） 内部程序 在固定地点 (S) PPL-06","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"双金属指针式温度计\n压力式指针温度计\n膨胀式指针温度计","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,4 °C"},{"name":"","range":"50 °C to 400 °C","cmc":"1,0 °C"},{"name":"","range":"400 °C to 600 °C","cmc":"2,0 °C"}],"regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Ručkové bimetalové teploměry Ručkové manometrické teploměry Ručkové dilatační teploměry Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PPL-06","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Ručkové bimetalové teploměry\nRučkové manometrické teploměry\nRučkové dilatační teploměry"},{"_id":"23d5bcbe5570b235d1ef756a","lab_id":"6af574790ecd48de0c70624d","country":"PL","accr_number":"AP 108","accr_body":"PCA","test_object":"Termometry wskazówkowe bimetalowe\nTermometry wskazówkowe manometryczne\nTermometry wskazówkowe dylatacyjne","test_object_en":"Bimetallic dial thermometers\nPressure-spring dial thermometers\nExpansion dial thermometers","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electrical thermometry)","parameters":[{"name":"","range":"-50 °C do 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C do 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C do 600 °C","cmc":"2,0 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C to 600 °C","cmc":"2,0 °C"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do 50 °C CMC 0,5 °C\n50 °C do 250 °C CMC 1,0 °C\n250 °C do 600 °C CMC 2,0 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PPL-06, PPLW-01","norm_bases":["PPL-06","PPLW-01"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electrical thermometry)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Termometry wskazówkowe bimetalowe\nTermometry wskazówkowe manometryczne\nTermometry wskazówkowe dylatacyjne Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do 50 °C CMC 0,5 °C\n50 °C do 250 °C CMC 1,0 °C\n250 °C do 600 °C CMC 2,0 °C\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PPL-06, PPLW-01 Termometry wskazowkowe bimetalowe\nTermometry wskazowkowe manometryczne\nTermometry wskazowkowe dylatacyjne Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n-50 °C do 50 °C CMC 0,5 °C\n50 °C do 250 °C CMC 1,0 °C\n250 °C do 600 °C CMC 2,0 °C\nProcedura wewnetrzna; Poza stala lokalizacja (P) PPL-06, PPLW-01","search_en":"Bimetallic dial thermometers Pressure-spring dial thermometers Expansion dial thermometers Calibration — Temperature (non-electrical thermometry) Internal procedure; Outside of permanent location (P) Temperature (non-electrical thermometry) Internal procedure Outside of permanent location (P) PPL-06, PPLW-01","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-1"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C to 600 °C","cmc":"2,0 °C"}],"regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Bimetall-Zeigerthermometer Manometrische Zeigerthermometer Ausdehnungs-Zeigerthermometer Kalibrierung — Temperatur (nichtelektrische Thermometrie) Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Außerhalb des festen Standorts (P) PPL-06, PPLW-01","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Bimetall-Zeigerthermometer\nManometrische Zeigerthermometer\nAusdehnungs-Zeigerthermometer","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C to 600 °C","cmc":"2,0 °C"}],"regulatory_area_zh":"温度（非电测温）","search_zh":"双金属指针式温度计 压力式指针温度计 膨胀式指针温度计 校准 — 温度（非电测温） 内部程序；固定地点以外 (P) 温度（非电测温） 内部程序 固定地点以外 (P) PPL-06, PPLW-01","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"双金属指针式温度计\n压力式指针温度计\n膨胀式指针温度计","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"-50 °C to 50 °C","cmc":"0,5 °C"},{"name":"","range":"50 °C to 250 °C","cmc":"1,0 °C"},{"name":"","range":"250 °C to 600 °C","cmc":"2,0 °C"}],"regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Ručkové bimetalové teploměry Ručkové manometrické teploměry Ručkové dilatační teploměry Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Mimo stálé pracoviště (P) Teplota (neelektrická termometrie) Vnitřní postup Mimo stálou lokalitu (P) PPL-06, PPLW-01","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Ručkové bimetalové teploměry\nRučkové manometrické teploměry\nRučkové dilatační teploměry"}],"has_pdf":true}