{"lab":{"_id":"6ade8b72ff06824761708162","accr_number":"AP 061","country":"PL","imported_at":"2026-10-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S)","activity_conducted_en":"at permanent location (S)","address":"ul. Czerniakowska 16, 00-701 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"23.07.2020","city":"Warszawa","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 % i jest wyrażona w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The measurement uncertainty value for CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the measured value.","cycle_from":"04.01.2024","cycle_to":"27.01.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"9.01","pl":"wielkości magnetyczne","en":"magnetic quantities"},{"codes":"9.02","pl":"wielkości elektromagnetyczne","en":"electromagnetic quantities"},{"codes":"11.01","pl":"strumień objętości (przepływ – gazy)","en":"volume flow rate (flow – gases)"},{"codes":"11.02","pl":"prędkość powietrza (przepływ – gazy)","en":"air velocity (flow – gases)"}],"has_en":true,"has_zh":false,"issue":{"no":"22","date":"26.11.2025"},"issue_date":"26.11.2025","issue_number":"22","lab_division":"Zespół Laboratoriów Wzorcujących","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.0512075,52.1997558]},"map_coord":[52.1997558,21.0512075],"map_geo":"nominatim-street","methods_count":5,"name":"Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy","parse_date":"2026-10-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-15T12:00:00.000Z","pdf_files":["AP_061.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: wielkości magnetyczne, wielkości elektromagnetyczne, strumień objętości (przepływ – gazy), prędkość powietrza (przepływ – gazy). W stałej lokalizacji (S).","search_text":"centralny instytut ochrony pracy - państwowy instytut badawczy zespół laboratoriów wzorcujących ul. czerniakowska 16, 00-701 warszawa laboratorium wzorcujące. wielkości mierzone: wielkości magnetyczne, wielkości elektromagnetyczne, strumień objętości (przepływ – gazy), prędkość powietrza (przepływ – gazy). w stałej lokalizacji (s). ap 061 ap061 laboratorium wzorcujące wzorcowanie kalibracja magnetic quantities electromagnetic quantities volume flow rate (flow – gases) air velocity (flow – gases) centralny instytut ochrony pracy - panstwowy instytut badawczy zespol laboratoriow wzorcujacych ul. czerniakowska 16, 00-701 warszawa laboratorium wzorcujace. wielkosci mierzone: wielkosci magnetyczne, wielkosci elektromagnetyczne, strumien objetosci (przeplyw – gazy), predkosc powietrza (przeplyw – gazy). w stalej lokalizacji (s). ap 061 ap061 laboratorium wzorcujace wzorcowanie kalibracja magnetic quantities electromagnetic quantities volume flow rate (flow – gases) air velocity (flow – gases)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20061,podmiot.html","source_pdf_sha256":"98eeed065abc9e8a1596096a9b0fa177566972cb87b16fe3aa89e90591601a48","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/15/a84e4408ad2ca4cbfe6b276fd7ba0e85/AP%20061.pdf","status":"active","updated_at":"2026-10-15T12:00:00.000Z","valid_from":"28-01-2004","valid_until":"27-01-2028","website":"www.ciop.pl"},"methods":[{"_id":"b90f8306610a82194c6fd54a","lab_id":"6ade8b72ff06824761708162","country":"PL","accr_number":"AP 061","accr_body":"PCA","test_object":"Mierniki do pomiaru pól magnetostatycznych\nMierniki do pomiaru pól elektromagnetycznych\nMierniki natężenia pola magnetycznego\nMierniki indukcji magnetycznej","test_object_en":"Meters for measuring magnetostatic fields\nMeters for measuring electromagnetic fields\nMagnetic field strength meters\nMagnetic induction meters","methodology":"Wzorcowanie — Wielkości magnetyczne","methodology_en":"Calibration — Magnetic quantities","parameters":[{"name":"dla pola magnetostatycznego","range":"0,0001 mT do 100 mT","cmc":"2,8 %"},{"name":"dla pola magnetostatycznego","range":"100 mT do 500 mT","cmc":"0,1 %"},{"name":"dla pola magnetycznego zmiennego, 20 Hz do 1000 Hz","range":"0,1 A/m do 2000 A/m","cmc":"3,4 %"},{"name":"dla pola magnetycznego zmiennego, 20 Hz do 1000 Hz","range":"0,1 A/m do 30000 A/m","cmc":"4,0%"},{"name":"dla pola magnetycznego zmiennego, 1 kHz do 50 kHz","range":"0,1 A/m do 150 A/m","cmc":"3,0%"},{"name":"dla pola magnetycznego zmiennego, 50 kHz do 100 kHz","range":"0,1 A/m do 150 A/m","cmc":"5,0%"}],"parameters_en":[{"name":"for magnetostatic field","range":"0,0001 mT to 100 mT","cmc":"2,8 %"},{"name":"for magnetostatic field","range":"100 mT to 500 mT","cmc":"0,1 %"},{"name":"for alternating magnetic field, 20 Hz to 1000 Hz","range":"0,1 A/m to 2000 A/m","cmc":"3,4 %"},{"name":"for alternating magnetic field, 20 Hz to 1000 Hz","range":"0,1 A/m to 30000 A/m","cmc":"4,0%"},{"name":"for alternating magnetic field, 1 kHz to 50 kHz","range":"0,1 A/m to 150 A/m","cmc":"3,0%"},{"name":"for alternating magnetic field, 50 kHz to 100 kHz","range":"0,1 A/m to 150 A/m","cmc":"5,0%"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości magnetyczne\nZakres:\ndla pola magnetostatycznego 0,0001 mT do 100 mT CMC 2,8 %\ndla pola magnetostatycznego 100 mT do 500 mT CMC 0,1 %\ndla pola magnetycznego zmiennego, 20 Hz do 1000 Hz 0,1 A/m do 2000 A/m CMC 3,4 %\ndla pola magnetycznego zmiennego, 20 Hz do 1000 Hz 0,1 A/m do 30000 A/m CMC 4,0%\ndla pola magnetycznego zmiennego, 1 kHz do 50 kHz 0,1 A/m do 150 A/m CMC 3,0%\ndla pola magnetycznego zmiennego, 50 kHz do 100 kHz 0,1 A/m do 150 A/m CMC 5,0%\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PWS/NA4-7 w oparciu o IEEE Std 1309:2013; PWS/NA4-30","norm_bases":["PWS/NA4-7","IEEE Std 1309:2013","PWS/NA4-30"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości magnetyczne","regulatory_area_en":"Magnetic quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki do pomiaru pól magnetostatycznych\nMierniki do pomiaru pól elektromagnetycznych\nMierniki natężenia pola magnetycznego\nMierniki indukcji magnetycznej Wzorcowanie — Wielkości magnetyczne\nZakres:\ndla pola magnetostatycznego 0,0001 mT do 100 mT CMC 2,8 %\ndla pola magnetostatycznego 100 mT do 500 mT CMC 0,1 %\ndla pola magnetycznego zmiennego, 20 Hz do 1000 Hz 0,1 A/m do 2000 A/m CMC 3,4 %\ndla pola magnetycznego zmiennego, 20 Hz do 1000 Hz 0,1 A/m do 30000 A/m CMC 4,0%\ndla pola magnetycznego zmiennego, 1 kHz do 50 kHz 0,1 A/m do 150 A/m CMC 3,0%\ndla pola magnetycznego zmiennego, 50 kHz do 100 kHz 0,1 A/m do 150 A/m CMC 5,0%\nProcedura wewnętrzna; W stałej lokalizacji (S) PWS/NA4-7 w oparciu o IEEE Std 1309:2013; PWS/NA4-30 Mierniki do pomiaru pol magnetostatycznych\nMierniki do pomiaru pol elektromagnetycznych\nMierniki natezenia pola magnetycznego\nMierniki indukcji magnetycznej Wzorcowanie — Wielkosci magnetyczne\nZakres:\ndla pola magnetostatycznego 0,0001 mT do 100 mT CMC 2,8 %\ndla pola magnetostatycznego 100 mT do 500 mT CMC 0,1 %\ndla pola magnetycznego zmiennego, 20 Hz do 1000 Hz 0,1 A/m do 2000 A/m CMC 3,4 %\ndla pola magnetycznego zmiennego, 20 Hz do 1000 Hz 0,1 A/m do 30000 A/m CMC 4,0%\ndla pola magnetycznego zmiennego, 1 kHz do 50 kHz 0,1 A/m do 150 A/m CMC 3,0%\ndla pola magnetycznego zmiennego, 50 kHz do 100 kHz 0,1 A/m do 150 A/m CMC 5,0%\nProcedura wewnetrzna; W stalej lokalizacji (S) PWS/NA4-7 w oparciu o IEEE Std 1309:2013; PWS/NA4-30","search_en":"Meters for measuring magnetostatic fields\nMeters for measuring electromagnetic fields\nMagnetic field strength meters\nMagnetic induction meters Calibration — Magnetic quantities\nScope:\nfor magnetostatic field 0,0001 mT to 100 mT CMC 2,8 %\nfor magnetostatic field 100 mT to 500 mT CMC 0,1 %\nfor alternating magnetic field, 20 Hz to 1000 Hz 0,1 A/m to 2000 A/m CMC 3,4 %\nfor alternating magnetic field, 20 Hz to 1000 Hz 0,1 A/m to 30000 A/m CMC 4,0%\nfor alternating magnetic field, 1 kHz to 50 kHz 0,1 A/m to 150 A/m CMC 3,0%\nfor alternating magnetic field, 50 kHz to 100 kHz 0,1 A/m to 150 A/m CMC 5,0%\nInternal procedure; At permanent location (S) PWS/NA4-7 w oparciu o IEEE Std 1309:2013; PWS/NA4-30","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75ff4b54ba999dbf3644a483","lab_id":"6ade8b72ff06824761708162","country":"PL","accr_number":"AP 061","accr_body":"PCA","test_object":"Mierniki do pomiaru pól elektromagnetycznych\nMierniki natężenia pola elektrycznego","test_object_en":"Meters for measuring electromagnetic fields\nElectric field strength meters","methodology":"Wzorcowanie — Wielkości elektromagnetyczne","methodology_en":"Calibration — Electromagnetic quantities","parameters":[{"name":"15 Hz do 1000 Hz","range":"100 V/m do 25000 V/m","cmc":"2,2 %"},{"name":"50 Hz do 100 kHz","range":"1 V/m do 17000 V/m","cmc":"5,9 %"},{"name":"0,1 MHz do 0,5 MHz","range":"0,5 V/m do 450 V/m","cmc":"19,2 %"},{"name":"0,5 MHz do 130 MHz","range":"0,5 V/m do 450 V/m","cmc":"11,8 %"},{"name":"130 MHz do 230 MHz","range":"0,5 V/m do 450 V/m","cmc":"15,6 %"},{"name":"230 MHz do 410 MHz","range":"0,5 V/m do 100 V/m","cmc":"12,0 %"},{"name":"410 MHz 890 MHz","range":"0,5 V/m do 60 V/m","cmc":"36,3 %"},{"name":"900 MHz","range":"0,5 V/m do 100 V/m","cmc":"15,8 %"},{"name":"910 MHz do 2500 MHz","range":"0,5 V/m do 60 V/m","cmc":"44,6 %"},{"name":"2500 MHz do 5000 MHz","range":"0,5 V/m do 45 V/m","cmc":"68,3 %"}],"parameters_en":[{"name":"15 Hz to 1000 Hz","range":"100 V/m to 25000 V/m","cmc":"2,2 %"},{"name":"50 Hz to 100 kHz","range":"1 V/m to 17000 V/m","cmc":"5,9 %"},{"name":"0,1 MHz to 0,5 MHz","range":"0,5 V/m to 450 V/m","cmc":"19,2 %"},{"name":"0,5 MHz to 130 MHz","range":"0,5 V/m to 450 V/m","cmc":"11,8 %"},{"name":"130 MHz to 230 MHz","range":"0,5 V/m to 450 V/m","cmc":"15,6 %"},{"name":"230 MHz to 410 MHz","range":"0,5 V/m to 100 V/m","cmc":"12,0 %"},{"name":"410 MHz 890 MHz","range":"0,5 V/m to 60 V/m","cmc":"36,3 %"},{"name":"900 MHz","range":"0,5 V/m to 100 V/m","cmc":"15,8 %"},{"name":"910 MHz to 2500 MHz","range":"0,5 V/m to 60 V/m","cmc":"44,6 %"},{"name":"2500 MHz to 5000 MHz","range":"0,5 V/m to 45 V/m","cmc":"68,3 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Wielkości elektromagnetyczne\nZakres:\n15 Hz do 1000 Hz 100 V/m do 25000 V/m CMC 2,2 %\n50 Hz do 100 kHz 1 V/m do 17000 V/m CMC 5,9 %\n0,1 MHz do 0,5 MHz 0,5 V/m do 450 V/m CMC 19,2 %\n0,5 MHz do 130 MHz 0,5 V/m do 450 V/m CMC 11,8 %\n130 MHz do 230 MHz 0,5 V/m do 450 V/m CMC 15,6 %\n230 MHz do 410 MHz 0,5 V/m do 100 V/m CMC 12,0 %\n410 MHz 890 MHz 0,5 V/m do 60 V/m CMC 36,3 %\n900 MHz 0,5 V/m do 100 V/m CMC 15,8 %\n910 MHz do 2500 MHz 0,5 V/m do 60 V/m CMC 44,6 %\n2500 MHz do 5000 MHz 0,5 V/m do 45 V/m CMC 68,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PWS/NA4-1 w oparciu o IEEE Std 1309:2013; PWS/NA4-13 w oparciu o IEEE Std 1309:2013","norm_bases":["PWS/NA4-1","PWS/NA4-13","IEEE Std 1309:2013"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Wielkości elektromagnetyczne","regulatory_area_en":"Electromagnetic quantities","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki do pomiaru pól elektromagnetycznych\nMierniki natężenia pola elektrycznego Wzorcowanie — Wielkości elektromagnetyczne\nZakres:\n15 Hz do 1000 Hz 100 V/m do 25000 V/m CMC 2,2 %\n50 Hz do 100 kHz 1 V/m do 17000 V/m CMC 5,9 %\n0,1 MHz do 0,5 MHz 0,5 V/m do 450 V/m CMC 19,2 %\n0,5 MHz do 130 MHz 0,5 V/m do 450 V/m CMC 11,8 %\n130 MHz do 230 MHz 0,5 V/m do 450 V/m CMC 15,6 %\n230 MHz do 410 MHz 0,5 V/m do 100 V/m CMC 12,0 %\n410 MHz 890 MHz 0,5 V/m do 60 V/m CMC 36,3 %\n900 MHz 0,5 V/m do 100 V/m CMC 15,8 %\n910 MHz do 2500 MHz 0,5 V/m do 60 V/m CMC 44,6 %\n2500 MHz do 5000 MHz 0,5 V/m do 45 V/m CMC 68,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PWS/NA4-1 w oparciu o IEEE Std 1309:2013; PWS/NA4-13 w oparciu o IEEE Std 1309:2013 Mierniki do pomiaru pol elektromagnetycznych\nMierniki natezenia pola elektrycznego Wzorcowanie — Wielkosci elektromagnetyczne\nZakres:\n15 Hz do 1000 Hz 100 V/m do 25000 V/m CMC 2,2 %\n50 Hz do 100 kHz 1 V/m do 17000 V/m CMC 5,9 %\n0,1 MHz do 0,5 MHz 0,5 V/m do 450 V/m CMC 19,2 %\n0,5 MHz do 130 MHz 0,5 V/m do 450 V/m CMC 11,8 %\n130 MHz do 230 MHz 0,5 V/m do 450 V/m CMC 15,6 %\n230 MHz do 410 MHz 0,5 V/m do 100 V/m CMC 12,0 %\n410 MHz 890 MHz 0,5 V/m do 60 V/m CMC 36,3 %\n900 MHz 0,5 V/m do 100 V/m CMC 15,8 %\n910 MHz do 2500 MHz 0,5 V/m do 60 V/m CMC 44,6 %\n2500 MHz do 5000 MHz 0,5 V/m do 45 V/m CMC 68,3 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PWS/NA4-1 w oparciu o IEEE Std 1309:2013; PWS/NA4-13 w oparciu o IEEE Std 1309:2013","search_en":"Meters for measuring electromagnetic fields\nElectric field strength meters Calibration — Electromagnetic quantities\nScope:\n15 Hz to 1000 Hz 100 V/m to 25000 V/m CMC 2,2 %\n50 Hz to 100 kHz 1 V/m to 17000 V/m CMC 5,9 %\n0,1 MHz to 0,5 MHz 0,5 V/m to 450 V/m CMC 19,2 %\n0,5 MHz to 130 MHz 0,5 V/m to 450 V/m CMC 11,8 %\n130 MHz to 230 MHz 0,5 V/m to 450 V/m CMC 15,6 %\n230 MHz to 410 MHz 0,5 V/m to 100 V/m CMC 12,0 %\n410 MHz 890 MHz 0,5 V/m to 60 V/m CMC 36,3 %\n900 MHz 0,5 V/m to 100 V/m CMC 15,8 %\n910 MHz to 2500 MHz 0,5 V/m to 60 V/m CMC 44,6 %\n2500 MHz to 5000 MHz 0,5 V/m to 45 V/m CMC 68,3 %\nInternal procedure; At permanent location (S) PWS/NA4-1 w oparciu o IEEE Std 1309:2013; PWS/NA4-13 w oparciu o IEEE Std 1309:2013","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fecbc4f81706bf81ebb4b1ee","lab_id":"6ade8b72ff06824761708162","country":"PL","accr_number":"AP 061","accr_body":"PCA","test_object":"Przepływomierze mierników wydatku energetycznego","test_object_en":"Flowmeters of energy expenditure meters","methodology":"Wzorcowanie — Strumień objętości (przepływ – gazy)","methodology_en":"Calibration — Volume flow rate (flow – gases)","parameters":[{"name":"","range":"10 dm³/min do 65 dm³/min","cmc":"2,3 %"}],"parameters_en":[{"name":"","range":"10 dm³/min to 65 dm³/min","cmc":"2,3 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Strumień objętości (przepływ – gazy)\n10 dm³/min do 65 dm³/min CMC 2,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PWS/LM-2","norm_bases":["PWS/LM-2"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Strumień objętości (przepływ – gazy)","regulatory_area_en":"Volume flow rate (flow – gases)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przepływomierze mierników wydatku energetycznego Wzorcowanie — Strumień objętości (przepływ – gazy)\n10 dm³/min do 65 dm³/min CMC 2,3 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PWS/LM-2 Przeplywomierze miernikow wydatku energetycznego Wzorcowanie — Strumien objetosci (przeplyw – gazy)\n10 dm³/min do 65 dm³/min CMC 2,3 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PWS/LM-2","search_en":"Flowmeters of energy expenditure meters Calibration — Volume flow rate (flow – gases)\n10 dm³/min to 65 dm³/min CMC 2,3 %\nInternal procedure; At permanent location (S) PWS/LM-2","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b85fc3bc912e451ddeab30a","lab_id":"6ade8b72ff06824761708162","country":"PL","accr_number":"AP 061","accr_body":"PCA","test_object":"Aspiratory","test_object_en":"Aspirators","methodology":"Wzorcowanie — Strumień objętości (przepływ – gazy)","methodology_en":"Calibration — Volume flow rate (flow – gases)","parameters":[{"name":"","range":"1 dm³/min do 5 dm³/min","cmc":"0,1 dm³/min"}],"parameters_en":[{"name":"","range":"1 dm³/min to 5 dm³/min","cmc":"0,1 dm³/min"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Strumień objętości (przepływ – gazy)\n1 dm³/min do 5 dm³/min CMC 0,1 dm³/min\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PWS/LM-7","norm_bases":["PWS/LM-7"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Strumień objętości (przepływ – gazy)","regulatory_area_en":"Volume flow rate (flow – gases)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Aspiratory Wzorcowanie — Strumień objętości (przepływ – gazy)\n1 dm³/min do 5 dm³/min CMC 0,1 dm³/min\nProcedura wewnętrzna; W stałej lokalizacji (S) PWS/LM-7 Aspiratory Wzorcowanie — Strumien objetosci (przeplyw – gazy)\n1 dm³/min do 5 dm³/min CMC 0,1 dm³/min\nProcedura wewnetrzna; W stalej lokalizacji (S) PWS/LM-7","search_en":"Aspirators Calibration — Volume flow rate (flow – gases)\n1 dm³/min to 5 dm³/min CMC 0,1 dm³/min\nInternal procedure; At permanent location (S) PWS/LM-7","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ab3ce856e2dce94245b055fd","lab_id":"6ade8b72ff06824761708162","country":"PL","accr_number":"AP 061","accr_body":"PCA","test_object":"Anemometry\nTermoanemometry","test_object_en":"Anemometers\nThermal anemometers","methodology":"Wzorcowanie — Prędkość powietrza (przepływ – gazy)","methodology_en":"Calibration — Air velocity (flow – gases)","parameters":[{"name":"","range":"0,15 m/s do 1,25 m/s","cmc":"0,06 m/s"},{"name":"","range":"1,25 m/s do 7,5 m/s","cmc":"0,21 m/s"},{"name":"","range":"7,5 m/s do 40 m/s","cmc":"0,70 m/s"}],"parameters_en":[{"name":"","range":"0,15 m/s to 1,25 m/s","cmc":"0,06 m/s"},{"name":"","range":"1,25 m/s to 7,5 m/s","cmc":"0,21 m/s"},{"name":"","range":"7,5 m/s to 40 m/s","cmc":"0,70 m/s"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prędkość powietrza (przepływ – gazy)\nZakres:\n0,15 m/s do 1,25 m/s CMC 0,06 m/s\n1,25 m/s do 7,5 m/s CMC 0,21 m/s\n7,5 m/s do 40 m/s CMC 0,70 m/s\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PWS/NC5-1","norm_bases":["PWS/NC5-1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prędkość powietrza (przepływ – gazy)","regulatory_area_en":"Air velocity (flow – gases)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Anemometry\nTermoanemometry Wzorcowanie — Prędkość powietrza (przepływ – gazy)\nZakres:\n0,15 m/s do 1,25 m/s CMC 0,06 m/s\n1,25 m/s do 7,5 m/s CMC 0,21 m/s\n7,5 m/s do 40 m/s CMC 0,70 m/s\nProcedura wewnętrzna; W stałej lokalizacji (S) PWS/NC5-1 Anemometry\nTermoanemometry Wzorcowanie — Predkosc powietrza (przeplyw – gazy)\nZakres:\n0,15 m/s do 1,25 m/s CMC 0,06 m/s\n1,25 m/s do 7,5 m/s CMC 0,21 m/s\n7,5 m/s do 40 m/s CMC 0,70 m/s\nProcedura wewnetrzna; W stalej lokalizacji (S) PWS/NC5-1","search_en":"Anemometers\nThermal anemometers Calibration — Air velocity (flow – gases)\nScope:\n0,15 m/s to 1,25 m/s CMC 0,06 m/s\n1,25 m/s to 7,5 m/s CMC 0,21 m/s\n7,5 m/s to 40 m/s CMC 0,70 m/s\nInternal procedure; At permanent location (S) PWS/NC5-1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}