{"lab":{"_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","imported_at":"2026-10-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Ligocka 55, 43-502 Czechowice-Dziedzice","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"03.10.2023","city":"Czechowice-Dziedzice","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The uncertainty covered by the CMC is expressed in measurand units.","cycle_from":"26.11.2024","cycle_to":"19.12.2028","email_source":"PCA","en_official":false,"fields_of_testing":[{"codes":"1.02","pl":"prędkość","en":"speed"},{"codes":"1.03","pl":"odległość","en":"distance"},{"codes":"6.01","pl":"długość","en":"length"},{"codes":"10.01","pl":"czas (przedział czasu)","en":"time (time interval)"}],"has_en":true,"has_zh":false,"issue":{"no":"27","date":"26.11.2024"},"issue_date":"26.11.2024","issue_number":"27","lab_division":"Laboratorium Pomiarowe LONTEX","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[18.9911951,49.9012921]},"map_coord":[49.9012921,18.9911951],"map_geo":"nominatim-street","methods_count":7,"name":"LONTEX Group Spółka z ograniczoną odpowiedzialnością","parse_date":"2026-10-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-15T12:00:00.000Z","pdf_files":["AP_026.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: prędkość, odległość, długość, czas (przedział czasu). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"lontex group spółka z ograniczoną odpowiedzialnością laboratorium pomiarowe lontex ul. ligocka 55, 43-502 czechowice-dziedzice laboratorium wzorcujące. wielkości mierzone: prędkość, odległość, długość, czas (przedział czasu). w stałej lokalizacji (s) i/lub poza nią (p). ap 026 ap026 laboratorium wzorcujące wzorcowanie kalibracja speed distance length time (time interval) lontex group spolka z ograniczona odpowiedzialnoscia laboratorium pomiarowe lontex ul. ligocka 55, 43-502 czechowice-dziedzice laboratorium wzorcujace. wielkosci mierzone: predkosc, odleglosc, dlugosc, czas (przedzial czasu). w stalej lokalizacji (s) i/lub poza nia (p). ap 026 ap026 laboratorium wzorcujace wzorcowanie kalibracja speed distance length time (time interval)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20026,podmiot.html","source_pdf_sha256":"dd7c757c7730ab22916007e165a8f54892708785d4a94b1f731ec34e62806b7d","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/15/5962bc95334fafbe339fefe37cc9a5db/AP%20026.pdf","status":"active","updated_at":"2026-10-15T12:00:00.000Z","valid_from":"20-12-2000","valid_until":"19-12-2028","website":"www.lontex.pl"},"methods":[{"_id":"605edbe8ff7af94142dcdfa2","lab_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","accr_body":"PCA","test_object":"Przyrządy do sprawdzania tachografów samochodowych","test_object_en":"Instruments for checking vehicle tachographs","methodology":"Wzorcowanie — Prędkość","methodology_en":"Calibration — Speed","parameters":[{"name":"prędkość liniowa","range":"0,90 km/h do 180,00 km/h","cmc":"0,06 km/h"},{"name":"długość drogi","range":"100,0 m do 30000,0 m","cmc":"0,7 m"},{"name":"liczba obrotów","range":"0,01 obr do 30000,00 obr","cmc":"0,03 obr"},{"name":"liczba impulsów przypadająca na 1 km","range":"2500,0 imp/km do 30000,0 imp/km","cmc":"2 imp/km"}],"parameters_en":[{"name":"linear speed","range":"0,90 km/h to 180,00 km/h","cmc":"0,06 km/h"},{"name":"distance travelled","range":"100,0 m to 30000,0 m","cmc":"0,7 m"},{"name":"number of revolutions","range":"0,01 rev to 30000,00 rev","cmc":"0,03 rev"},{"name":"number of pulses per 1 km","range":"2500,0 pulses/km to 30000,0 pulses/km","cmc":"2 pulses/km"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prędkość\nZakres:\nprędkość liniowa 0,90 km/h do 180,00 km/h CMC 0,06 km/h\ndługość drogi 100,0 m do 30000,0 m CMC 0,7 m\nliczba obrotów 0,01 obr do 30000,00 obr CMC 0,03 obr\nliczba impulsów przypadająca na 1 km 2500,0 imp/km do 30000,0 imp/km CMC 2 imp/km\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"I-05","norm_bases":["I-05"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prędkość","regulatory_area_en":"Speed","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Przyrządy do sprawdzania tachografów samochodowych Wzorcowanie — Prędkość\nZakres:\nprędkość liniowa 0,90 km/h do 180,00 km/h CMC 0,06 km/h\ndługość drogi 100,0 m do 30000,0 m CMC 0,7 m\nliczba obrotów 0,01 obr do 30000,00 obr CMC 0,03 obr\nliczba impulsów przypadająca na 1 km 2500,0 imp/km do 30000,0 imp/km CMC 2 imp/km\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) I-05 Przyrzady do sprawdzania tachografow samochodowych Wzorcowanie — Predkosc\nZakres:\npredkosc liniowa 0,90 km/h do 180,00 km/h CMC 0,06 km/h\ndlugosc drogi 100,0 m do 30000,0 m CMC 0,7 m\nliczba obrotow 0,01 obr do 30000,00 obr CMC 0,03 obr\nliczba impulsow przypadajaca na 1 km 2500,0 imp/km do 30000,0 imp/km CMC 2 imp/km\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) I-05","search_en":"Instruments for checking vehicle tachographs Calibration — Speed\nScope:\nlinear speed 0,90 km/h to 180,00 km/h CMC 0,06 km/h\ndistance travelled 100,0 m to 30000,0 m CMC 0,7 m\nnumber of revolutions 0,01 rev to 30000,00 rev CMC 0,03 rev\nnumber of pulses per 1 km 2500,0 pulses/km to 30000,0 pulses/km CMC 2 pulses/km\nInternal procedure; At permanent location (S) and outside of it (P) I-05","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f384805104675a3738dae972","lab_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","accr_body":"PCA","test_object":"Tachometry","test_object_en":"Tachometers","methodology":"Wzorcowanie — Prędkość","methodology_en":"Calibration — Speed","parameters":[{"name":"prędkość obrotowa","range":"10 obr/min do 60000 obr/min","cmc":"0,1 obr/min"}],"parameters_en":[{"name":"rotational speed","range":"10 rpm to 60000 rpm","cmc":"0,1 rpm"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prędkość\nprędkość obrotowa 10 obr/min do 60000 obr/min CMC 0,1 obr/min\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"I-09","norm_bases":["I-09"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prędkość","regulatory_area_en":"Speed","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Tachometry Wzorcowanie — Prędkość\nprędkość obrotowa 10 obr/min do 60000 obr/min CMC 0,1 obr/min\nProcedura wewnętrzna; W stałej lokalizacji (S) I-09 Tachometry Wzorcowanie — Predkosc\npredkosc obrotowa 10 obr/min do 60000 obr/min CMC 0,1 obr/min\nProcedura wewnetrzna; W stalej lokalizacji (S) I-09","search_en":"Tachometers Calibration — Speed\nrotational speed 10 rpm to 60000 rpm CMC 0,1 rpm\nInternal procedure; At permanent location (S) I-09","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4366230172de2ce91b210360","lab_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","accr_body":"PCA","test_object":"Bazy drogowe","test_object_en":"Road measuring bases","methodology":"Wzorcowanie — Odległość","methodology_en":"Calibration — Distance","parameters":[{"name":"","range":"0 m do 20 m","cmc":"7 mm"},{"name":"","range":"0 m do 30 m","cmc":"7 mm"},{"name":"","range":"0 m do 40 m","cmc":"7 mm"},{"name":"","range":"0 m do 100 m","cmc":"13 mm"}],"parameters_en":[{"name":"","range":"0 m to 20 m","cmc":"7 mm"},{"name":"","range":"0 m to 30 m","cmc":"7 mm"},{"name":"","range":"0 m to 40 m","cmc":"7 mm"},{"name":"","range":"0 m to 100 m","cmc":"13 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia przy wykorzystaniu przymiaru wstęgowego; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method using a tape measure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia przy wykorzystaniu przymiaru wstęgowego","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method using a tape measure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Odległość\nZakres:\n0 m do 20 m CMC 7 mm\n0 m do 30 m CMC 7 mm\n0 m do 40 m CMC 7 mm\n0 m do 100 m CMC 13 mm\nProcedura wewnętrzna; Metoda bezpośrednia przy wykorzystaniu przymiaru wstęgowego; Poza stałą lokalizacją (P)","reference":"I-07","norm_bases":["I-07"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Odległość","regulatory_area_en":"Distance","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Bazy drogowe Wzorcowanie — Odległość\nZakres:\n0 m do 20 m CMC 7 mm\n0 m do 30 m CMC 7 mm\n0 m do 40 m CMC 7 mm\n0 m do 100 m CMC 13 mm\nProcedura wewnętrzna; Metoda bezpośrednia przy wykorzystaniu przymiaru wstęgowego; Poza stałą lokalizacją (P) I-07 Bazy drogowe Wzorcowanie — Odleglosc\nZakres:\n0 m do 20 m CMC 7 mm\n0 m do 30 m CMC 7 mm\n0 m do 40 m CMC 7 mm\n0 m do 100 m CMC 13 mm\nProcedura wewnetrzna; Metoda bezposrednia przy wykorzystaniu przymiaru wstegowego; Poza stala lokalizacja (P) I-07","search_en":"Road measuring bases Calibration — Distance\nScope:\n0 m to 20 m CMC 7 mm\n0 m to 30 m CMC 7 mm\n0 m to 40 m CMC 7 mm\n0 m to 100 m CMC 13 mm\nInternal procedure; Direct method using a tape measure; Outside of permanent location (P) I-07","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7fab4cbdfeb1901b1e101800","lab_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","accr_body":"PCA","test_object":"Wysokościomierze do pomiaru wysokości kół pojazdów","test_object_en":"Height gauges for measuring vehicle wheel height","methodology":"Wzorcowanie — Długość","methodology_en":"Calibration — Length","parameters":[{"name":"","range":"100,0 mm do 1000,0 mm","cmc":"0,6 mm"}],"parameters_en":[{"name":"","range":"100,0 mm to 1000,0 mm","cmc":"0,6 mm"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia przy wykorzystaniu wysokościomierza wzorcowego; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a reference height gauge; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia przy wykorzystaniu wysokościomierza wzorcowego","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a reference height gauge","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Długość\n100,0 mm do 1000,0 mm CMC 0,6 mm\nProcedura wewnętrzna; Metoda bezpośrednia przy wykorzystaniu wysokościomierza wzorcowego; W stałej lokalizacji (S)","reference":"I-08","norm_bases":["I-08"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Długość","regulatory_area_en":"Length","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wysokościomierze do pomiaru wysokości kół pojazdów Wzorcowanie — Długość\n100,0 mm do 1000,0 mm CMC 0,6 mm\nProcedura wewnętrzna; Metoda bezpośrednia przy wykorzystaniu wysokościomierza wzorcowego; W stałej lokalizacji (S) I-08 Wysokosciomierze do pomiaru wysokosci kol pojazdow Wzorcowanie — Dlugosc\n100,0 mm do 1000,0 mm CMC 0,6 mm\nProcedura wewnetrzna; Metoda bezposrednia przy wykorzystaniu wysokosciomierza wzorcowego; W stalej lokalizacji (S) I-08","search_en":"Height gauges for measuring vehicle wheel height Calibration — Length\n100,0 mm to 1000,0 mm CMC 0,6 mm\nInternal procedure; Direct method using a reference height gauge; At permanent location (S) I-08","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"37ba47409d638799154fafb2","lab_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","accr_body":"PCA","test_object":"Względne odchylenie czasu\nChronokomparatory cyfrowe","test_object_en":"Relative time deviation\nDigital chronocomparators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"o rozdzielczości 0,01 s/d","range":"-120,0 s/d do 120,0 s/d","cmc":"0,03 s/d"}],"parameters_en":[{"name":"with resolution of 0,01 s/d","range":"-120,0 s/d to 120,0 s/d","cmc":"0,03 s/d"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method using a clock signal generator; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method using a clock signal generator","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\no rozdzielczości 0,01 s/d -120,0 s/d do 120,0 s/d CMC 0,03 s/d\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; W stałej lokalizacji (S)","reference":"I-06","norm_bases":["I-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Względne odchylenie czasu\nChronokomparatory cyfrowe Wzorcowanie — Czas (przedział czasu)\no rozdzielczości 0,01 s/d -120,0 s/d do 120,0 s/d CMC 0,03 s/d\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; W stałej lokalizacji (S) I-06 Wzgledne odchylenie czasu\nChronokomparatory cyfrowe Wzorcowanie — Czas (przedzial czasu)\no rozdzielczosci 0,01 s/d -120,0 s/d do 120,0 s/d CMC 0,03 s/d\nProcedura wewnetrzna; Metoda bezposrednia przy uzyciu generatora przebiegow zegarowych; W stalej lokalizacji (S) I-06","search_en":"Relative time deviation\nDigital chronocomparators Calibration — Time (time interval)\nwith resolution of 0,01 s/d -120,0 s/d to 120,0 s/d CMC 0,03 s/d\nInternal procedure; Direct method using a clock signal generator; At permanent location (S) I-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8633784b75bc48f684810c89","lab_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","accr_body":"PCA","test_object":"Względne odchylenie czasu\nChronokomparatory cyfrowe","test_object_en":"Relative time deviation\nDigital chronocomparators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"o rozdzielczości 0,01 s/d","range":"-120,0 s/d do 120,0 s/d","cmc":"0,1 s/d"}],"parameters_en":[{"name":"with resolution of 0,01 s/d","range":"-120,0 s/d to 120,0 s/d","cmc":"0,1 s/d"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Direct method using a clock signal generator; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Direct method using a clock signal generator","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\no rozdzielczości 0,01 s/d -120,0 s/d do 120,0 s/d CMC 0,1 s/d\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; Poza stałą lokalizacją (P)","reference":"I-06","norm_bases":["I-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Względne odchylenie czasu\nChronokomparatory cyfrowe Wzorcowanie — Czas (przedział czasu)\no rozdzielczości 0,01 s/d -120,0 s/d do 120,0 s/d CMC 0,1 s/d\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; Poza stałą lokalizacją (P) I-06 Wzgledne odchylenie czasu\nChronokomparatory cyfrowe Wzorcowanie — Czas (przedzial czasu)\no rozdzielczosci 0,01 s/d -120,0 s/d do 120,0 s/d CMC 0,1 s/d\nProcedura wewnetrzna; Metoda bezposrednia przy uzyciu generatora przebiegow zegarowych; Poza stala lokalizacja (P) I-06","search_en":"Relative time deviation\nDigital chronocomparators Calibration — Time (time interval)\nwith resolution of 0,01 s/d -120,0 s/d to 120,0 s/d CMC 0,1 s/d\nInternal procedure; Direct method using a clock signal generator; Outside of permanent location (P) I-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3d14f463b7c7e06dab044efc","lab_id":"6ade8b71ff0682476170815e","country":"PL","accr_number":"AP 026","accr_body":"PCA","test_object":"Względne odchylenie czasu\nChronokomparatory cyfrowe","test_object_en":"Relative time deviation\nDigital chronocomparators","methodology":"Wzorcowanie — Czas (przedział czasu)","methodology_en":"Calibration — Time (time interval)","parameters":[{"name":"o rozdzielczości 0,1 s/d","range":"-120,0 s/d do 120,0 s/d","cmc":"0,1 s/d"},{"name":"o rozdzielczości 1 s/d","range":"-120,0 s/d do 120,0 s/d","cmc":"1 s/d"}],"parameters_en":[{"name":"with resolution of 0,1 s/d","range":"-120,0 s/d to 120,0 s/d","cmc":"0,1 s/d"},{"name":"with resolution of 1 s/d","range":"-120,0 s/d to 120,0 s/d","cmc":"1 s/d"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Direct method using a clock signal generator; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Direct method using a clock signal generator","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Czas (przedział czasu)\nZakres:\no rozdzielczości 0,1 s/d -120,0 s/d do 120,0 s/d CMC 0,1 s/d\no rozdzielczości 1 s/d -120,0 s/d do 120,0 s/d CMC 1 s/d\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; W stałej lokalizacji (S) i poza nią (P)","reference":"I-06","norm_bases":["I-06"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Czas (przedział czasu)","regulatory_area_en":"Time (time interval)","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Względne odchylenie czasu\nChronokomparatory cyfrowe Wzorcowanie — Czas (przedział czasu)\nZakres:\no rozdzielczości 0,1 s/d -120,0 s/d do 120,0 s/d CMC 0,1 s/d\no rozdzielczości 1 s/d -120,0 s/d do 120,0 s/d CMC 1 s/d\nProcedura wewnętrzna; Metoda bezpośrednia przy użyciu generatora przebiegów zegarowych; W stałej lokalizacji (S) i poza nią (P) I-06 Wzgledne odchylenie czasu\nChronokomparatory cyfrowe Wzorcowanie — Czas (przedzial czasu)\nZakres:\no rozdzielczosci 0,1 s/d -120,0 s/d do 120,0 s/d CMC 0,1 s/d\no rozdzielczosci 1 s/d -120,0 s/d do 120,0 s/d CMC 1 s/d\nProcedura wewnetrzna; Metoda bezposrednia przy uzyciu generatora przebiegow zegarowych; W stalej lokalizacji (S) i poza nia (P) I-06","search_en":"Relative time deviation\nDigital chronocomparators Calibration — Time (time interval)\nScope:\nwith resolution of 0,1 s/d -120,0 s/d to 120,0 s/d CMC 0,1 s/d\nwith resolution of 1 s/d -120,0 s/d to 120,0 s/d CMC 1 s/d\nInternal procedure; Direct method using a clock signal generator; At permanent location (S) and outside of it (P) I-06","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}