{"lab":{"_id":"6ade8b70ff0682476170815d","country":"PL","accr_number":"AP 009","imported_at":"2026-10-15T12:00:00.000Z","accr_body":"PCA","activity_conducted":"działające w stałej siedzibie (S)","activity_conducted_en":"acting in permanent facilities (S)","address":"ul. Ratuszowa 11, 03-450 Warszawa","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"21.06.2019","city":"Warszawa","cmc_note":"Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. and is expressed in measurand units.","cycle_from":"01.10.2026","cycle_to":"21.10.2030","email_source":"PCA","en_official":true,"fields_of_testing":[{"codes":"17.02","pl":"próżnia","en":"vacuum"}],"has_en":true,"has_zh":false,"issue":{"no":"18","date":"01.10.2026"},"issue_date":"01.10.2026","issue_number":"18","lab_division":"Laboratorium Badawczo-Pomiarowe Techniki Próżni","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[21.0322791,52.2583079]},"map_coord":[52.2583079,21.0322791],"map_geo":"nominatim-street","methods_count":3,"name":"Sieć Badawcza Łukasiewicz - Instytut Tele- i Radiotechniczny","parse_date":"2026-10-15T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parse_status":"parsed","parse_version":1,"parsed_at":"2026-10-15T12:00:00.000Z","pdf_files":["AP_009.pdf"],"scope_notes":[],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: próżnia. Działające w stałej siedzibie (S).","search_text":"sieć badawcza łukasiewicz - instytut tele- i radiotechniczny laboratorium badawczo-pomiarowe techniki próżni ul. ratuszowa 11, 03-450 warszawa laboratorium wzorcujące. wielkości mierzone: próżnia. działające w stałej siedzibie (s). ap 009 ap009 laboratorium wzorcujące wzorcowanie kalibracja vacuum siec badawcza lukasiewicz - instytut tele- i radiotechniczny laboratorium badawczo-pomiarowe techniki prozni ul. ratuszowa 11, 03-450 warszawa laboratorium wzorcujace. wielkosci mierzone: proznia. dzialajace w stalej siedzibie (s). ap 009 ap009 laboratorium wzorcujace wzorcowanie kalibracja vacuum","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20009,podmiot.html","source_pdf_sha256":"c3ce555a8e6a66118812c80920688a01cbd8250f3545ec3debec291eefeda4fc","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/10/15/4e3a434cddb9a7e6a6f3323d18813c30/AP%20009.pdf","status":"active","updated_at":"2026-10-15T12:00:00.000Z","valid_from":"22-10-1998","valid_until":"21-10-2030","website":"www.it.org.pl"},"methods":[{"_id":"7a6eb0636107998220ce4894","lab_id":"6ade8b70ff0682476170815d","country":"PL","accr_number":"AP 009","accr_body":"PCA","test_object":"Próżniomierze\np ≤ 10⁵ Pa","test_object_en":"Vacuum gauges\np ≤ 10⁵ Pa","methodology":"Wzorcowanie — Próżnia","methodology_en":"Calibration — Vacuum","parameters":[{"name":"","range":"10⁵ Pa do 10⁻¹ Pa","cmc":"2 %"}],"parameters_en":[{"name":"","range":"10⁵ Pa to 10⁻¹ Pa","cmc":"2 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Próżnia\n10⁵ Pa do 10⁻¹ Pa CMC 2 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PP-01/LTP","norm_bases":["PP-01/LTP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Próżnia","regulatory_area_en":"Vacuum","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Próżniomierze\np ≤ 10⁵ Pa Wzorcowanie — Próżnia\n10⁵ Pa do 10⁻¹ Pa CMC 2 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PP-01/LTP Prozniomierze\np ≤ 10⁵ Pa Wzorcowanie — Proznia\n10⁵ Pa do 10⁻¹ Pa CMC 2 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PP-01/LTP","search_en":"Vacuum gauges\np ≤ 10⁵ Pa Calibration — Vacuum\n10⁵ Pa to 10⁻¹ Pa CMC 2 %\nInternal procedure; At permanent location (S) PP-01/LTP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8579e01eea00244ac9ba11dd","lab_id":"6ade8b70ff0682476170815d","country":"PL","accr_number":"AP 009","accr_body":"PCA","test_object":"Próżniomierze\np ≤ 10⁻¹ Pa","test_object_en":"Vacuum gauges\np ≤ 10⁻¹ Pa","methodology":"Wzorcowanie — Próżnia","methodology_en":"Calibration — Vacuum","parameters":[{"name":"","range":"10⁻¹ Pa do 10⁻⁶ Pa","cmc":"5 %"}],"parameters_en":[{"name":"","range":"10⁻¹ Pa to 10⁻⁶ Pa","cmc":"5 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Próżnia\n10⁻¹ Pa do 10⁻⁶ Pa CMC 5 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PP-02/LTP","norm_bases":["PP-02/LTP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Próżnia","regulatory_area_en":"Vacuum","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Próżniomierze\np ≤ 10⁻¹ Pa Wzorcowanie — Próżnia\n10⁻¹ Pa do 10⁻⁶ Pa CMC 5 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PP-02/LTP Prozniomierze\np ≤ 10⁻¹ Pa Wzorcowanie — Proznia\n10⁻¹ Pa do 10⁻⁶ Pa CMC 5 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PP-02/LTP","search_en":"Vacuum gauges\np ≤ 10⁻¹ Pa Calibration — Vacuum\n10⁻¹ Pa to 10⁻⁶ Pa CMC 5 %\nInternal procedure; At permanent location (S) PP-02/LTP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c73afda9641c533dfd3e2d5","lab_id":"6ade8b70ff0682476170815d","country":"PL","accr_number":"AP 009","accr_body":"PCA","test_object":"Przyrządy do sprawdzania nieszczelności (helowe nieszczelności wzorcowe)","test_object_en":"Helium leak detectors","methodology":"Wzorcowanie — Próżnia","methodology_en":"Calibration — Vacuum","parameters":[{"name":"","range":"10⁻⁵ Pa·m³/s do 10⁻¹⁰ Pa·m³/s","cmc":"10 %"}],"parameters_en":[{"name":"","range":"10⁻⁵ Pa·m³/s to 10⁻¹⁰ Pa·m³/s","cmc":"10 %"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Próżnia\n10⁻⁵ Pa·m³/s do 10⁻¹⁰ Pa·m³/s CMC 10 %\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PP-03/LTP","norm_bases":["PP-03/LTP"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Próżnia","regulatory_area_en":"Vacuum","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przyrządy do sprawdzania nieszczelności (helowe nieszczelności wzorcowe) Wzorcowanie — Próżnia\n10⁻⁵ Pa·m³/s do 10⁻¹⁰ Pa·m³/s CMC 10 %\nProcedura wewnętrzna; W stałej lokalizacji (S) PP-03/LTP Przyrzady do sprawdzania nieszczelnosci (helowe nieszczelnosci wzorcowe) Wzorcowanie — Proznia\n10⁻⁵ Pa·m³/s do 10⁻¹⁰ Pa·m³/s CMC 10 %\nProcedura wewnetrzna; W stalej lokalizacji (S) PP-03/LTP","search_en":"Helium leak detectors Calibration — Vacuum\n10⁻⁵ Pa·m³/s to 10⁻¹⁰ Pa·m³/s CMC 10 %\nInternal procedure; At permanent location (S) PP-03/LTP","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}