{"lab":{"_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","imported_at":"2026-11-14T12:00:00.000Z","accr_body":"PCA","activity_conducted":"w stałej lokalizacji (S) i/lub poza nią (P)","activity_conducted_en":"at permanent location (S) and/or outside of permanent location (P)","address":"ul. Łowiecka 6/8, 50-220 Wrocław","approver":"Katarzyna Wiśniewska","categories":["metrology"],"certificate_date":"13.11.2020","city":"Wrocław","cmc_note":"Niepewność pomiaru dla CMC stanowi niepewność rozszerzoną przy prawdopodobieństwie rozszerzenia ok. 95 %. Niepewność pomiaru dla CMC wyrażona jest w jednostkach wielkości mierzonej. Wartość niepewności pomiaru dla CMC wyrażona w procentach jest niepewnością pomiaru względną i dotyczy procentowego udziału w wartości wielkości mierzonej.","cmc_note_en":"The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The uncertainty covered by the CMC is expressed in measurand units. The measurement uncertainty value for CMC, expressed as a percentage, is the relative measurement uncertainty and refers to the percentage of the value of the measured quantity.","cycle_from":"19.10.2026","cycle_to":"18.11.2030","email_source":"PCA","en_official":true,"fields_of_testing":[{"codes":"7.01","pl":"napięcie DC","en":"DC voltage","de":"Gleichspannung","zh":"直流电压","cs":"stejnosměrné napětí (DC)"},{"codes":"7.02","pl":"prąd DC","en":"DC current","de":"DC-Strom","zh":"直流电流","cs":"proud DC"},{"codes":"7.03","pl":"napięcie AC","en":"AC voltage","de":"AC-Spannung","zh":"交流电压","cs":"napětí AC"},{"codes":"7.04","pl":"prąd AC","en":"current","de":"AC-Strom","zh":"交流电流","cs":"proud AC"},{"codes":"7.05","pl":"rezystancja DC","en":"DC resistance","de":"DC-Widerstand","zh":"直流电阻","cs":"odpor DC"},{"codes":"7.15","pl":"elektryczna symulacja wielkości","en":"electrical simulation of quantities","de":"elektrische Simulation von Größen","zh":"量值的电模拟","cs":"elektrická simulace veličin"},{"codes":"17.01","pl":"ciśnienie","en":"pressure","de":"Druck","zh":"压力","cs":"tlak"},{"codes":"19.01","pl":"temperatura (termometria elektryczna)","en":"temperature (electrical thermometry)","de":"Temperatur (elektrische Thermometrie)","zh":"温度（电测温）","cs":"teplota (elektrická termometrie)"},{"codes":"19.02","pl":"temperatura (termometria nieelektryczna)","en":"temperature (non-electrical thermometry)","de":"Temperatur (nichtelektrische Thermometrie)","zh":"温度（非电测温）","cs":"teplota (neelektrická termometrie)"}],"has_en":true,"has_zh":true,"issue":{"no":"22","date":"19.10.2026"},"issue_date":"19.10.2026","issue_number":"22","lab_division":"Zespół Laboratoriów Pomiarowych","lab_kind":"calibration","lab_type":"calibration","location":{"type":"Point","coordinates":[17.0264172,51.1235452]},"map_coord":[51.1235452,17.0264172],"map_geo":"nominatim-street","methods_count":19,"name":"ZEC DIAGPOM Sp. z o.o.","parse_date":"2026-11-14T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-1","parse_status":"parsed","parse_version":1,"parsed_at":"2026-11-14T12:00:00.000Z","pdf_files":["AP_007.pdf"],"scope_notes":[{"pl":"1) Wartość CMC dotyczy punktowego pomiaru temperatury w komorze wzorcowanego obiektu","en":"1) The CMC value relates to a point temperature measurement within the chamber of the calibrated object"}],"scope_summary":"Laboratorium wzorcujące. Wielkości mierzone: napięcie DC, prąd DC, napięcie AC, prąd AC, rezystancja DC, elektryczna symulacja wielkości, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna). W stałej lokalizacji (S) i/lub poza nią (P).","search_text":"zec diagpom sp. z o.o. zespół laboratoriów pomiarowych ul. łowiecka 6/8, 50-220 wrocław laboratorium wzorcujące. wielkości mierzone: napięcie dc, prąd dc, napięcie ac, prąd ac, rezystancja dc, elektryczna symulacja wielkości, ciśnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna). w stałej lokalizacji (s) i/lub poza nią (p). ap 007 ap007 laboratorium wzorcujące wzorcowanie kalibracja dc voltage dc current ac voltage current dc resistance electrical simulation of quantities pressure temperature (electrical thermometry) temperature (non-electrical thermometry) zec diagpom sp. z o.o. zespol laboratoriow pomiarowych ul. lowiecka 6/8, 50-220 wroclaw laboratorium wzorcujace. wielkosci mierzone: napiecie dc, prad dc, napiecie ac, prad ac, rezystancja dc, elektryczna symulacja wielkosci, cisnienie, temperatura (termometria elektryczna), temperatura (termometria nieelektryczna). w stalej lokalizacji (s) i/lub poza nia (p). ap 007 ap007 laboratorium wzorcujace wzorcowanie kalibracja dc voltage dc current ac voltage current dc resistance electrical simulation of quantities pressure temperature (electrical thermometry) temperature (non-electrical thermometry)","source_lang":"pl","source_page_url":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-wzorcujace/AP%20007,podmiot.html","source_pdf_sha256":"930e7138f3f7cc77cd611b81e2bb3230dfd659af7810509cb72ed8013a45ba96","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/11/14/d85fca3f4bf65396abfd55a2e0a7e4a9/AP%20007.pdf","status":"active","updated_at":"2026-11-14T12:00:00.000Z","valid_from":"19-11-1998","valid_until":"18-11-2030","website":"www.diagpom.pl","lab_division_en":"Measurement Laboratories Group","cmc_note_de":"Die Messunsicherheit der CMC ist die erweiterte Messunsicherheit mit einer Überdeckungswahrscheinlichkeit von ca. 95 %. Die Messunsicherheit der CMC wird in Einheiten der Messgröße angegeben. Ein in Prozent angegebener Wert der Messunsicherheit der CMC ist eine relative Messunsicherheit und bezieht sich auf den prozentualen Anteil am Wert der Messgröße.","has_de":true,"lab_division_de":"Messlaborverbund","cmc_note_zh":"CMC测量不确定度为包含概率约95 %的扩展不确定度。CMC测量不确定度以被测量的单位表示。以百分数表示的CMC测量不确定度值为相对测量不确定度，指占被测量值的百分比。","lab_division_zh":"测量实验室组","cmc_note_cs":"Nejistota měření CMC je rozšířená nejistota při pravděpodobnosti pokrytí přibližně 95 %. Nejistota měření CMC je vyjádřena v jednotkách měřené veličiny. Hodnota nejistoty měření CMC vyjádřená v procentech je relativní nejistota měření a vztahuje se k procentnímu podílu na hodnotě měřené veličiny.","has_cs":true,"lab_division_cs":"Soubor měřicích laboratoří","pelny_cs":true},"methods":[{"_id":"e555e8631a6336a48ae5de23","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry","test_object_en":"Analog voltage meters\nDigital voltage meters\nMultimeters","methodology":"Wzorcowanie — Napięcie DC","methodology_en":"Calibration — DC voltage","parameters":[{"name":"","range":"0,2 mV do 100 mV","cmc":"0,009 mV"},{"name":"","range":"100 mV do 1000 mV","cmc":"6 · 10⁻⁵ · U + 0,005 mV"},{"name":"","range":"1 V do 1000 V","cmc":"0,005 %"}],"parameters_en":[{"name":"","range":"0,2 mV to 100 mV","cmc":"0,009 mV"},{"name":"","range":"100 mV to 1000 mV","cmc":"6 · 10⁻⁵ · U + 0,005 mV"},{"name":"","range":"1 V to 1000 V","cmc":"0,005 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie DC\nZakres:\n0,2 mV do 100 mV CMC 0,009 mV\n100 mV do 1000 mV CMC 6 · 10⁻⁵ · U + 0,005 mV\n1 V do 1000 V CMC 0,005 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PT1","PT3","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie DC","regulatory_area_en":"DC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (mV)","note_en":"U – measured value (mV)","search_text":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry Wzorcowanie — Napięcie DC\nZakres:\n0,2 mV do 100 mV CMC 0,009 mV\n100 mV do 1000 mV CMC 6 · 10⁻⁵ · U + 0,005 mV\n1 V do 1000 V CMC 0,005 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0 Mierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMultimetry Wzorcowanie — Napiecie DC\nZakres:\n0,2 mV do 100 mV CMC 0,009 mV\n100 mV do 1000 mV CMC 6 · 10⁻⁵ · U + 0,005 mV\n1 V do 1000 V CMC 0,005 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","search_en":"Analog voltage meters Digital voltage meters Multimeters Calibration — DC voltage Internal procedure; Direct method; At permanent location (S) DC voltage Internal procedure Direct method At permanent location (S) PT1 PT3 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":0,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT1 PT3 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Spannung","parameters_de":[{"name":"","range":"0,2 mV to 100 mV","cmc":"0,009 mV"},{"name":"","range":"100 mV to 1000 mV","cmc":"6 · 10⁻⁵ · U + 0,005 mV"},{"name":"","range":"1 V to 1000 V","cmc":"0,005 %"}],"reference_de":"PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Spannung","search_de":"Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Multimeter Kalibrierung — DC-Spannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nMultimeter","methodology_zh":"校准 — 直流电压","parameters_zh":[{"name":"","range":"0,2 mV to 100 mV","cmc":"0,009 mV"},{"name":"","range":"100 mV to 1000 mV","cmc":"6 · 10⁻⁵ · U + 0,005 mV"},{"name":"","range":"1 V to 1000 V","cmc":"0,005 %"}],"reference_zh":"PT1 PT3 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电压","search_zh":"模拟电压表 数字电压表 万用表 校准 — 直流电压 内部程序；直接法；在固定地点 (S) 直流电压 内部程序 直接法 在固定地点 (S) PT1 PT3 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电压表\n数字电压表\n万用表","methodology_cs":"Kalibrace — Napětí DC","parameters_cs":[{"name":"","range":"0,2 mV to 100 mV","cmc":"0,009 mV"},{"name":"","range":"100 mV to 1000 mV","cmc":"6 · 10⁻⁵ · U + 0,005 mV"},{"name":"","range":"1 V to 1000 V","cmc":"0,005 %"}],"reference_cs":"PT1 PT3 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Napětí DC","search_cs":"Analogové měřiče napětí Digitální měřiče napětí Multimetry Kalibrace — Napětí DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PT1 PT3 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče napětí\nDigitální měřiče napětí\nMultimetry"},{"_id":"16886e52546a183c3029567d","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry","test_object_en":"Analog current meters\nDigital current meters\nMultimeters","methodology":"Wzorcowanie — Prąd DC","methodology_en":"Calibration — DC current","parameters":[{"name":"","range":"0,2 mA do 100 mA","cmc":"0,03 %"},{"name":"","range":"0,1 A do 1 A","cmc":"0,04 %"},{"name":"","range":"1 A do 3 A","cmc":"0,03 %"},{"name":"","range":"3 A do 20 A","cmc":"0,25 %"}],"parameters_en":[{"name":"","range":"0,2 mA to 100 mA","cmc":"0,03 %"},{"name":"","range":"0,1 A to 1 A","cmc":"0,04 %"},{"name":"","range":"1 A to 3 A","cmc":"0,03 %"},{"name":"","range":"3 A to 20 A","cmc":"0,25 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd DC\nZakres:\n0,2 mA do 100 mA CMC 0,03 %\n0,1 A do 1 A CMC 0,04 %\n1 A do 3 A CMC 0,03 %\n3 A do 20 A CMC 0,25 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PT1","PT3","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd DC","regulatory_area_en":"DC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd DC\nZakres:\n0,2 mA do 100 mA CMC 0,03 %\n0,1 A do 1 A CMC 0,04 %\n1 A do 3 A CMC 0,03 %\n3 A do 20 A CMC 0,25 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0 Mierniki pradu analogowe\nMierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad DC\nZakres:\n0,2 mA do 100 mA CMC 0,03 %\n0,1 A do 1 A CMC 0,04 %\n1 A do 3 A CMC 0,03 %\n3 A do 20 A CMC 0,25 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","search_en":"Analog current meters Digital current meters Multimeters Calibration — DC current Internal procedure; Direct method; At permanent location (S) DC current Internal procedure Direct method At permanent location (S) PT1 PT3 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":1,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT1 PT3 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Strom","parameters_de":[{"name":"","range":"0,2 mA to 100 mA","cmc":"0,03 %"},{"name":"","range":"0,1 A to 1 A","cmc":"0,04 %"},{"name":"","range":"1 A to 3 A","cmc":"0,03 %"},{"name":"","range":"3 A to 20 A","cmc":"0,25 %"}],"reference_de":"PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Strom","search_de":"Analoge Strommessgeräte Digitale Strommessgeräte Multimeter Kalibrierung — DC-Strom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Strommessgeräte\nDigitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 直流电流","parameters_zh":[{"name":"","range":"0,2 mA to 100 mA","cmc":"0,03 %"},{"name":"","range":"0,1 A to 1 A","cmc":"0,04 %"},{"name":"","range":"1 A to 3 A","cmc":"0,03 %"},{"name":"","range":"3 A to 20 A","cmc":"0,25 %"}],"reference_zh":"PT1 PT3 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电流","search_zh":"模拟电流表 数字电流表 万用表 校准 — 直流电流 内部程序；直接法；在固定地点 (S) 直流电流 内部程序 直接法 在固定地点 (S) PT1 PT3 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电流表\n数字电流表\n万用表","methodology_cs":"Kalibrace — Proud DC","parameters_cs":[{"name":"","range":"0,2 mA to 100 mA","cmc":"0,03 %"},{"name":"","range":"0,1 A to 1 A","cmc":"0,04 %"},{"name":"","range":"1 A to 3 A","cmc":"0,03 %"},{"name":"","range":"3 A to 20 A","cmc":"0,25 %"}],"reference_cs":"PT1 PT3 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Proud DC","search_cs":"Analogové měřiče proudu Digitální měřiče proudu Multimetry Kalibrace — Proud DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PT1 PT3 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče proudu\nDigitální měřiče proudu\nMultimetry"},{"_id":"f9503622223bf12d6020b09a","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry","test_object_en":"Analog voltage meters\nDigital voltage meters\nMultimeters","methodology":"Wzorcowanie — Napięcie AC","methodology_en":"Calibration — AC voltage","parameters":[{"name":"50 Hz","range":"1,0 mV do 100 mV","cmc":"5 · 10⁻⁴ · U + 0,01 mV"},{"name":"50 Hz","range":"0,1 V do 10 V","cmc":"0,06 %"},{"name":"50 Hz","range":"10 V do 1000 V","cmc":"0,01 %"}],"parameters_en":[{"name":"50 Hz","range":"1,0 mV to 100 mV","cmc":"5 · 10⁻⁴ · U + 0,01 mV"},{"name":"50 Hz","range":"0,1 V to 10 V","cmc":"0,06 %"},{"name":"50 Hz","range":"10 V to 1000 V","cmc":"0,01 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Napięcie AC\nZakres:\n50 Hz 1,0 mV do 100 mV CMC 5 · 10⁻⁴ · U + 0,01 mV\n50 Hz 0,1 V do 10 V CMC 0,06 %\n50 Hz 10 V do 1000 V CMC 0,01 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PT1","PT3","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Napięcie AC","regulatory_area_en":"AC voltage","outside_premises":false,"location_of_activity":"S","note":"U – wielkość mierzona (mV)","note_en":"U – measured value (mV)","search_text":"Mierniki napięcia analogowe\nMierniki napięcia cyfrowe\nMultimetry Wzorcowanie — Napięcie AC\nZakres:\n50 Hz 1,0 mV do 100 mV CMC 5 · 10⁻⁴ · U + 0,01 mV\n50 Hz 0,1 V do 10 V CMC 0,06 %\n50 Hz 10 V do 1000 V CMC 0,01 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0 Mierniki napiecia analogowe\nMierniki napiecia cyfrowe\nMultimetry Wzorcowanie — Napiecie AC\nZakres:\n50 Hz 1,0 mV do 100 mV CMC 5 · 10⁻⁴ · U + 0,01 mV\n50 Hz 0,1 V do 10 V CMC 0,06 %\n50 Hz 10 V do 1000 V CMC 0,01 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","search_en":"Analog voltage meters Digital voltage meters Multimeters Calibration — AC voltage Internal procedure; Direct method; At permanent location (S) AC voltage Internal procedure Direct method At permanent location (S) 50 Hz 50 Hz 50 Hz PT1 PT3 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":2,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT1 PT3 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — Wechselspannung","parameters_de":[{"name":"50 Hz","range":"1,0 mV to 100 mV","cmc":"5 · 10⁻⁴ · U + 0,01 mV"},{"name":"50 Hz","range":"0,1 V bis 10 V","cmc":"0,06 %"},{"name":"50 Hz","range":"10 V to 1000 V","cmc":"0,01 %"}],"reference_de":"PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"AC-Spannung","search_de":"Analoge Spannungsmessgeräte Digitale Spannungsmessgeräte Multimeter Kalibrierung — Wechselspannung Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Spannung Internes Verfahren Direktes Verfahren Am festen Standort (S) 50 Hz 50 Hz 50 Hz PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Spannungsmessgeräte\nDigitale Spannungsmessgeräte\nMultimeter","methodology_zh":"校准 — 交流电压","parameters_zh":[{"name":"50 Hz","range":"1,0 mV to 100 mV","cmc":"5 · 10⁻⁴ · U + 0,01 mV"},{"name":"50 Hz","range":"0,1 V to 10 V","cmc":"0,06 %"},{"name":"50 Hz","range":"10 V to 1000 V","cmc":"0,01 %"}],"reference_zh":"PT1 PT3 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"交流电压","search_zh":"模拟电压表 数字电压表 万用表 校准 — 交流电压 内部程序；直接法；在固定地点 (S) 交流电压 内部程序 直接法 在固定地点 (S) 50 Hz 50 Hz 50 Hz PT1 PT3 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电压表\n数字电压表\n万用表","methodology_cs":"Kalibrace — Napětí AC","parameters_cs":[{"name":"50 Hz","range":"1,0 mV to 100 mV","cmc":"5 · 10⁻⁴ · U + 0,01 mV"},{"name":"50 Hz","range":"0,1 V to 10 V","cmc":"0,06 %"},{"name":"50 Hz","range":"10 V to 1000 V","cmc":"0,01 %"}],"reference_cs":"PT1 PT3 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Napětí AC","search_cs":"Analogové měřiče napětí Digitální měřiče napětí Multimetry Kalibrace — Napětí AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Napětí AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 50 Hz 50 Hz 50 Hz PT1 PT3 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče napětí\nDigitální měřiče napětí\nMultimetry"},{"_id":"66af9c64583f22d94245453c","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry","test_object_en":"Analog current meters\nDigital current meters\nMultimeters","methodology":"Wzorcowanie — Prąd AC","methodology_en":"Calibration — AC current","parameters":[{"name":"50 Hz","range":"0,02 mA do 0,2 mA","cmc":"0,4 %"},{"name":"50 Hz","range":"0,3 mA do 200 mA","cmc":"0,15 %"},{"name":"50 Hz","range":"201 mA do 3 A","cmc":"0,35 %"},{"name":"50 Hz","range":"3 A do 20 A","cmc":"0,17 %"}],"parameters_en":[{"name":"50 Hz","range":"0,02 mA to 0,2 mA","cmc":"0,4 %"},{"name":"50 Hz","range":"0,3 mA to 200 mA","cmc":"0,15 %"},{"name":"50 Hz","range":"201 mA to 3 A","cmc":"0,35 %"},{"name":"50 Hz","range":"3 A to 20 A","cmc":"0,17 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Prąd AC\nZakres:\n50 Hz 0,02 mA do 0,2 mA CMC 0,4 %\n50 Hz 0,3 mA do 200 mA CMC 0,15 %\n50 Hz 201 mA do 3 A CMC 0,35 %\n50 Hz 3 A do 20 A CMC 0,17 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PT1","PT3","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Prąd AC","regulatory_area_en":"AC current","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Mierniki prądu analogowe\nMierniki prądu cyfrowe\nMultimetry Wzorcowanie — Prąd AC\nZakres:\n50 Hz 0,02 mA do 0,2 mA CMC 0,4 %\n50 Hz 0,3 mA do 200 mA CMC 0,15 %\n50 Hz 201 mA do 3 A CMC 0,35 %\n50 Hz 3 A do 20 A CMC 0,17 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0 Mierniki pradu analogowe\nMierniki pradu cyfrowe\nMultimetry Wzorcowanie — Prad AC\nZakres:\n50 Hz 0,02 mA do 0,2 mA CMC 0,4 %\n50 Hz 0,3 mA do 200 mA CMC 0,15 %\n50 Hz 201 mA do 3 A CMC 0,35 %\n50 Hz 3 A do 20 A CMC 0,17 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PT1 PT3 w oparciu o EURAMET cg-15 v.3.0","search_en":"Analog current meters Digital current meters Multimeters Calibration — AC current Internal procedure; Direct method; At permanent location (S) AC current Internal procedure Direct method At permanent location (S) 50 Hz 50 Hz 50 Hz 50 Hz PT1 PT3 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":3,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT1 PT3 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — Wechselstrom","parameters_de":[{"name":"50 Hz","range":"0,02 mA to 0,2 mA","cmc":"0,4 %"},{"name":"50 Hz","range":"0,3 mA to 200 mA","cmc":"0,15 %"},{"name":"50 Hz","range":"201 mA to 3 A","cmc":"0,35 %"},{"name":"50 Hz","range":"3 A to 20 A","cmc":"0,17 %"}],"reference_de":"PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"AC-Strom","search_de":"Analoge Strommessgeräte Digitale Strommessgeräte Multimeter Kalibrierung — Wechselstrom Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) AC-Strom Internes Verfahren Direktes Verfahren Am festen Standort (S) 50 Hz 50 Hz 50 Hz 50 Hz PT1 PT3 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Analoge Strommessgeräte\nDigitale Strommessgeräte\nMultimeter","methodology_zh":"校准 — 交流电流","parameters_zh":[{"name":"50 Hz","range":"0,02 mA to 0,2 mA","cmc":"0,4 %"},{"name":"50 Hz","range":"0,3 mA to 200 mA","cmc":"0,15 %"},{"name":"50 Hz","range":"201 mA to 3 A","cmc":"0,35 %"},{"name":"50 Hz","range":"3 A to 20 A","cmc":"0,17 %"}],"reference_zh":"PT1 PT3 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"交流电流","search_zh":"模拟电流表 数字电流表 万用表 校准 — 交流电流 内部程序；直接法；在固定地点 (S) 交流电流 内部程序 直接法 在固定地点 (S) 50 Hz 50 Hz 50 Hz 50 Hz PT1 PT3 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"模拟电流表\n数字电流表\n万用表","methodology_cs":"Kalibrace — Proud AC","parameters_cs":[{"name":"50 Hz","range":"0,02 mA to 0,2 mA","cmc":"0,4 %"},{"name":"50 Hz","range":"0,3 mA to 200 mA","cmc":"0,15 %"},{"name":"50 Hz","range":"201 mA to 3 A","cmc":"0,35 %"},{"name":"50 Hz","range":"3 A to 20 A","cmc":"0,17 %"}],"reference_cs":"PT1 PT3 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Proud AC","search_cs":"Analogové měřiče proudu Digitální měřiče proudu Multimetry Kalibrace — Proud AC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Proud AC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) 50 Hz 50 Hz 50 Hz 50 Hz PT1 PT3 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Analogové měřiče proudu\nDigitální měřiče proudu\nMultimetry"},{"_id":"68fd9f732cd8083c6aff7c8f","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Multimetry","test_object_en":"Multimeters","methodology":"Wzorcowanie — Rezystancja DC","methodology_en":"Calibration — DC resistance","parameters":[{"name":"","range":"0,1 Ω do 100 Ω","cmc":"0,6 %"},{"name":"","range":"100 Ω do 1 MΩ","cmc":"0,06 %"},{"name":"","range":"1 MΩ do 19 MΩ","cmc":"0,04 %"}],"parameters_en":[{"name":"","range":"0,1 Ω to 100 Ω","cmc":"0,6 %"},{"name":"","range":"100 Ω to 1 MΩ","cmc":"0,06 %"},{"name":"","range":"1 MΩ to 19 MΩ","cmc":"0,04 %"}],"technique":"Procedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Rezystancja DC\nZakres:\n0,1 Ω do 100 Ω CMC 0,6 %\n100 Ω do 1 MΩ CMC 0,06 %\n1 MΩ do 19 MΩ CMC 0,04 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S)","reference":"PT3 w oparciu o EURAMET cg-15 v.3.0","norm_bases":["PT3","EURAMET cg-15 v.3.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Rezystancja DC","regulatory_area_en":"DC resistance","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Multimetry Wzorcowanie — Rezystancja DC\nZakres:\n0,1 Ω do 100 Ω CMC 0,6 %\n100 Ω do 1 MΩ CMC 0,06 %\n1 MΩ do 19 MΩ CMC 0,04 %\nProcedura wewnętrzna; Metoda bezpośrednia; W stałej lokalizacji (S) PT3 w oparciu o EURAMET cg-15 v.3.0 Multimetry Wzorcowanie — Rezystancja DC\nZakres:\n0,1 Ω do 100 Ω CMC 0,6 %\n100 Ω do 1 MΩ CMC 0,06 %\n1 MΩ do 19 MΩ CMC 0,04 %\nProcedura wewnetrzna; Metoda bezposrednia; W stalej lokalizacji (S) PT3 w oparciu o EURAMET cg-15 v.3.0","search_en":"Multimeters Calibration — DC resistance Internal procedure; Direct method; At permanent location (S) DC resistance Internal procedure Direct method At permanent location (S) PT3 based on EURAMET cg-15 v.3.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":4,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT3 based on EURAMET cg-15 v.3.0","methodology_de":"Kalibrierung — DC-Widerstand","parameters_de":[{"name":"","range":"0,1 Ω to 100 Ω","cmc":"0,6 %"},{"name":"","range":"100 Ω to 1 MΩ","cmc":"0,06 %"},{"name":"","range":"1 MΩ to 19 MΩ","cmc":"0,04 %"}],"reference_de":"PT3 auf Grundlage von EURAMET cg-15 v.3.0","regulatory_area_de":"DC-Widerstand","search_de":"Multimeter Kalibrierung — DC-Widerstand Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S) DC-Widerstand Internes Verfahren Direktes Verfahren Am festen Standort (S) PT3 auf Grundlage von EURAMET cg-15 v.3.0","technique_de":"Interne Verfahrensanweisung; Direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Multimeter","methodology_zh":"校准 — 直流电阻","parameters_zh":[{"name":"","range":"0,1 Ω to 100 Ω","cmc":"0,6 %"},{"name":"","range":"100 Ω to 1 MΩ","cmc":"0,06 %"},{"name":"","range":"1 MΩ to 19 MΩ","cmc":"0,04 %"}],"reference_zh":"PT3 依据EURAMET cg-15 v.3.0","regulatory_area_zh":"直流电阻","search_zh":"万用表 校准 — 直流电阻 内部程序；直接法；在固定地点 (S) 直流电阻 内部程序 直接法 在固定地点 (S) PT3 依据EURAMET cg-15 v.3.0","technique_zh":"内部程序；直接法；在固定地点 (S)","techniques_zh":["内部程序","直接法","在固定地点 (S)"],"test_object_zh":"万用表","methodology_cs":"Kalibrace — Odpor DC","parameters_cs":[{"name":"","range":"0,1 Ω to 100 Ω","cmc":"0,6 %"},{"name":"","range":"100 Ω to 1 MΩ","cmc":"0,06 %"},{"name":"","range":"1 MΩ to 19 MΩ","cmc":"0,04 %"}],"reference_cs":"PT3 na základě EURAMET cg-15 v.3.0","regulatory_area_cs":"Odpor DC","search_cs":"Multimetry Kalibrace — Odpor DC Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S) Odpor DC Vnitřní postup Přímá metoda Ve stálé lokalitě (S) PT3 na základě EURAMET cg-15 v.3.0","technique_cs":"Vnitřní postup; Přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Multimetry"},{"_id":"4184aa6d0e9b13009f9adcec","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury, w tym regulatory temperatury\nWskaźniki (mierniki) temperatury współpracujące z czujnikami termoelektrycznymi","test_object_en":"Temperature indicators (meters), including temperature controllers\nTemperature indicators (meters) cooperating with thermoelectric sensors","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"","range":"-180 °C do 0 °C","cmc":"0,4 °C"},{"name":"","range":"0 °C do 1200 °C","cmc":"0,3 °C"},{"name":"","range":"1200 °C do 1600 °C","cmc":"0,6 °C"}],"parameters_en":[{"name":"","range":"-180 °C to 0 °C","cmc":"0,4 °C"},{"name":"","range":"0 °C to 1200 °C","cmc":"0,3 °C"},{"name":"","range":"1200 °C to 1600 °C","cmc":"0,6 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia/bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; Indirect/direct method; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia/bezpośrednia","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","Indirect/direct method","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-180 °C do 0 °C CMC 0,4 °C\n0 °C do 1200 °C CMC 0,3 °C\n1200 °C do 1600 °C CMC 0,6 °C\nProcedura wewnętrzna; Metoda pośrednia/bezpośrednia; W stałej lokalizacji (S) i poza nią (P)","reference":"PT5 w oparciu o EURAMET cg-11 v. 2.0","norm_bases":["PT5","EURAMET cg-11 v. 2.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":true,"location_of_activity":"S, P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury, w tym regulatory temperatury\nWskaźniki (mierniki) temperatury współpracujące z czujnikami termoelektrycznymi Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-180 °C do 0 °C CMC 0,4 °C\n0 °C do 1200 °C CMC 0,3 °C\n1200 °C do 1600 °C CMC 0,6 °C\nProcedura wewnętrzna; Metoda pośrednia/bezpośrednia; W stałej lokalizacji (S) i poza nią (P) PT5 w oparciu o EURAMET cg-11 v. 2.0 Wskazniki (mierniki) temperatury, w tym regulatory temperatury\nWskazniki (mierniki) temperatury wspolpracujace z czujnikami termoelektrycznymi Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-180 °C do 0 °C CMC 0,4 °C\n0 °C do 1200 °C CMC 0,3 °C\n1200 °C do 1600 °C CMC 0,6 °C\nProcedura wewnetrzna; Metoda posrednia/bezposrednia; W stalej lokalizacji (S) i poza nia (P) PT5 w oparciu o EURAMET cg-11 v. 2.0","search_en":"Temperature indicators (meters), including temperature controllers Temperature indicators (meters) cooperating with thermoelectric sensors Calibration — Electric quantity simulation Internal procedure; Indirect/direct method; At permanent location (S) and outside of it (P) Electric quantity simulation Internal procedure Indirect/direct method At permanent location (S) and outside of it (P) PT5 based on EURAMET cg-11 v. 2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":5,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT5 based on EURAMET cg-11 v. 2.0","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-180 °C to 0 °C","cmc":"0,4 °C"},{"name":"","range":"0 °C to 1200 °C","cmc":"0,3 °C"},{"name":"","range":"1200 °C to 1600 °C","cmc":"0,6 °C"}],"reference_de":"PT5 auf Grundlage von EURAMET cg-11 v. 2.0","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (Messgeräte), einschließlich Temperaturregler Temperaturanzeiger (-messgeräte) für Thermoelemente Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Indirektes/direktes Verfahren; Am festen Standort (S) und außerhalb (P) Elektrische Simulation von Größen Internes Verfahren Indirektes/direktes Verfahren Am festen Standort (S) und außerhalb (P) PT5 auf Grundlage von EURAMET cg-11 v. 2.0","technique_de":"Internes Verfahren; Indirektes/direktes Verfahren; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Indirektes/direktes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Temperaturanzeiger (Messgeräte), einschließlich Temperaturregler\nTemperaturanzeiger (-messgeräte) für Thermoelemente","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-180 °C to 0 °C","cmc":"0,4 °C"},{"name":"","range":"0 °C to 1200 °C","cmc":"0,3 °C"},{"name":"","range":"1200 °C to 1600 °C","cmc":"0,6 °C"}],"reference_zh":"PT5 依据EURAMET cg-11 v. 2.0","regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（测量仪），包括温度调节器 配用热电偶传感器的温度指示仪（表） 校准 — 物理量的电模拟 内部程序；间接/直接法；在固定地点 (S) 及固定地点以外 (P) 量值的电模拟 内部程序 间接/直接法 在固定地点 (S) 及固定地点以外 (P) PT5 依据EURAMET cg-11 v. 2.0","technique_zh":"内部程序；间接/直接法；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","间接/直接法","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"温度指示仪（测量仪），包括温度调节器\n配用热电偶传感器的温度指示仪（表）","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-180 °C to 0 °C","cmc":"0,4 °C"},{"name":"","range":"0 °C to 1200 °C","cmc":"0,3 °C"},{"name":"","range":"1200 °C to 1600 °C","cmc":"0,6 °C"}],"reference_cs":"PT5 na základě EURAMET cg-11 v. 2.0","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Indikátory (měřidla) teploty, včetně regulátorů teploty Ukazatele (měřidla) teploty pracující s termoelektrickými snímači Kalibrace — Elektrická simulace veličin Vnitřní postup; Nepřímá/přímá metoda; V trvalé lokalitě (S) i mimo ni (P) Elektrická simulace veličin Vnitřní postup Nepřímá/přímá metoda V trvalé lokalitě (S) i mimo ni (P) PT5 na základě EURAMET cg-11 v. 2.0","technique_cs":"Vnitřní postup; Nepřímá/přímá metoda; V trvalé lokalitě (S) i mimo ni (P)","techniques_cs":["Vnitřní postup","Nepřímá/přímá metoda","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Indikátory (měřidla) teploty, včetně regulátorů teploty\nUkazatele (měřidla) teploty pracující s termoelektrickými snímači"},{"_id":"4a654aaebbe9fea7f352dc93","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury, w tym regulatory temperatury","test_object_en":"Temperature indicators (meters), including temperature controllers","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"","range":"-180°C do 250°C","cmc":"0,1 °C"},{"name":"","range":"250°C do 350°C","cmc":"0,2 °C"},{"name":"","range":"350°C do 750°C","cmc":"0,3 °C"}],"parameters_en":[{"name":"","range":"-180°C to 250°C","cmc":"0,1 °C"},{"name":"","range":"250°C to 350°C","cmc":"0,2 °C"},{"name":"","range":"350°C to 750°C","cmc":"0,3 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia/bezpośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect/direct method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia/bezpośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect/direct method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-180°C do 250°C CMC 0,1 °C\n250°C do 350°C CMC 0,2 °C\n350°C do 750°C CMC 0,3 °C\nProcedura wewnętrzna; Metoda pośrednia/bezpośrednia; W stałej lokalizacji (S)","reference":"PT5 w oparciu o EURAMET cg-11 v. 2.0","norm_bases":["PT5","EURAMET cg-11 v. 2.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury, w tym regulatory temperatury Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-180°C do 250°C CMC 0,1 °C\n250°C do 350°C CMC 0,2 °C\n350°C do 750°C CMC 0,3 °C\nProcedura wewnętrzna; Metoda pośrednia/bezpośrednia; W stałej lokalizacji (S) PT5 w oparciu o EURAMET cg-11 v. 2.0 Wskazniki (mierniki) temperatury, w tym regulatory temperatury Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-180°C do 250°C CMC 0,1 °C\n250°C do 350°C CMC 0,2 °C\n350°C do 750°C CMC 0,3 °C\nProcedura wewnetrzna; Metoda posrednia/bezposrednia; W stalej lokalizacji (S) PT5 w oparciu o EURAMET cg-11 v. 2.0","search_en":"Temperature indicators (meters), including temperature controllers Calibration — Electric quantity simulation Internal procedure; Indirect/direct method; At permanent location (S) Electric quantity simulation Internal procedure Indirect/direct method At permanent location (S) PT5 based on EURAMET cg-11 v. 2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":6,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT5 based on EURAMET cg-11 v. 2.0","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-180°C to 250°C","cmc":"0,1 °C"},{"name":"","range":"250°C to 350°C","cmc":"0,2 °C"},{"name":"","range":"350°C to 750°C","cmc":"0,3 °C"}],"reference_de":"PT5 auf Grundlage von EURAMET cg-11 v. 2.0","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (Messgeräte), einschließlich Temperaturregler Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Indirektes/direktes Verfahren; Am festen Standort (S) Elektrische Simulation von Größen Internes Verfahren Indirektes/direktes Verfahren Am festen Standort (S) PT5 auf Grundlage von EURAMET cg-11 v. 2.0","technique_de":"Internes Verfahren; Indirektes/direktes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Indirektes/direktes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturanzeiger (Messgeräte), einschließlich Temperaturregler","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-180°C to 250°C","cmc":"0,1 °C"},{"name":"","range":"250°C to 350°C","cmc":"0,2 °C"},{"name":"","range":"350°C to 750°C","cmc":"0,3 °C"}],"reference_zh":"PT5 依据EURAMET cg-11 v. 2.0","regulatory_area_zh":"量值的电模拟","search_zh":"温度指示仪（测量仪），包括温度调节器 校准 — 物理量的电模拟 内部程序；间接/直接法；在固定地点 (S) 量值的电模拟 内部程序 间接/直接法 在固定地点 (S) PT5 依据EURAMET cg-11 v. 2.0","technique_zh":"内部程序；间接/直接法；在固定地点 (S)","techniques_zh":["内部程序","间接/直接法","在固定地点 (S)"],"test_object_zh":"温度指示仪（测量仪），包括温度调节器","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-180°C to 250°C","cmc":"0,1 °C"},{"name":"","range":"250°C to 350°C","cmc":"0,2 °C"},{"name":"","range":"350°C to 750°C","cmc":"0,3 °C"}],"reference_cs":"PT5 na základě EURAMET cg-11 v. 2.0","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Indikátory (měřidla) teploty, včetně regulátorů teploty Kalibrace — Elektrická simulace veličin Vnitřní postup; Nepřímá/přímá metoda; Ve stálé lokalitě (S) Elektrická simulace veličin Vnitřní postup Nepřímá/přímá metoda Ve stálé lokalitě (S) PT5 na základě EURAMET cg-11 v. 2.0","technique_cs":"Vnitřní postup; Nepřímá/přímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá/přímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Indikátory (měřidla) teploty, včetně regulátorů teploty"},{"_id":"9ef95235d61ba103d9d286e4","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Wskaźniki (mierniki) temperatury współpracujące z czujnikami rezystancyjnymi","test_object_en":"Temperature indicators (meters) cooperating with resistance sensors","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"","range":"-180°C do 0°C","cmc":"0,13 °C"},{"name":"","range":"0°C do 250°C","cmc":"0,3 °C"},{"name":"","range":"250°C do 750°C","cmc":"0,7 °C"}],"parameters_en":[{"name":"","range":"-180°C to 0°C","cmc":"0,13 °C"},{"name":"","range":"0°C to 250°C","cmc":"0,3 °C"},{"name":"","range":"250°C to 750°C","cmc":"0,7 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia/bezpośrednia; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Indirect/direct method; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Metoda pośrednia/bezpośrednia","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Indirect/direct method","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-180°C do 0°C CMC 0,13 °C\n0°C do 250°C CMC 0,3 °C\n250°C do 750°C CMC 0,7 °C\nProcedura wewnętrzna; Metoda pośrednia/bezpośrednia; Poza stałą lokalizacją (P)","reference":"PT5 w oparciu o EURAMET cg-11 v. 2.0","norm_bases":["PT5","EURAMET cg-11 v. 2.0"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Wskaźniki (mierniki) temperatury współpracujące z czujnikami rezystancyjnymi Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-180°C do 0°C CMC 0,13 °C\n0°C do 250°C CMC 0,3 °C\n250°C do 750°C CMC 0,7 °C\nProcedura wewnętrzna; Metoda pośrednia/bezpośrednia; Poza stałą lokalizacją (P) PT5 w oparciu o EURAMET cg-11 v. 2.0 Wskazniki (mierniki) temperatury wspolpracujace z czujnikami rezystancyjnymi Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-180°C do 0°C CMC 0,13 °C\n0°C do 250°C CMC 0,3 °C\n250°C do 750°C CMC 0,7 °C\nProcedura wewnetrzna; Metoda posrednia/bezposrednia; Poza stala lokalizacja (P) PT5 w oparciu o EURAMET cg-11 v. 2.0","search_en":"Temperature indicators (meters) cooperating with resistance sensors Calibration — Electric quantity simulation Internal procedure; Indirect/direct method; Outside of permanent location (P) Electric quantity simulation Internal procedure Indirect/direct method Outside of permanent location (P) PT5 based on EURAMET cg-11 v. 2.0","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":7,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT5 based on EURAMET cg-11 v. 2.0","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-180°C to 0°C","cmc":"0,13 °C"},{"name":"","range":"0°C to 250°C","cmc":"0,3 °C"},{"name":"","range":"250°C to 750°C","cmc":"0,7 °C"}],"reference_de":"PT5 auf Grundlage von EURAMET cg-11 v. 2.0","regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturanzeiger (-messgeräte) für Widerstandsthermometer Kalibrierung — Elektrische Simulation von Größen Internes Verfahren; Indirektes/direktes Verfahren; Außerhalb des festen Standorts (P) Elektrische Simulation von Größen Internes Verfahren Indirektes/direktes Verfahren Außerhalb des festen Standorts (P) PT5 auf Grundlage von EURAMET cg-11 v. 2.0","technique_de":"Internes Verfahren; Indirektes/direktes Verfahren; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Indirektes/direktes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Temperaturanzeiger (-messgeräte) für Widerstandsthermometer","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-180°C to 0°C","cmc":"0,13 °C"},{"name":"","range":"0°C to 250°C","cmc":"0,3 °C"},{"name":"","range":"250°C to 750°C","cmc":"0,7 °C"}],"reference_zh":"PT5 依据EURAMET cg-11 v. 2.0","regulatory_area_zh":"量值的电模拟","search_zh":"配用电阻传感器的温度指示仪（表） 校准 — 物理量的电模拟 内部程序；间接/直接法；固定地点以外 (P) 量值的电模拟 内部程序 间接/直接法 固定地点以外 (P) PT5 依据EURAMET cg-11 v. 2.0","technique_zh":"内部程序；间接/直接法；固定地点以外 (P)","techniques_zh":["内部程序","间接/直接法","固定地点以外 (P)"],"test_object_zh":"配用电阻传感器的温度指示仪（表）","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-180°C to 0°C","cmc":"0,13 °C"},{"name":"","range":"0°C to 250°C","cmc":"0,3 °C"},{"name":"","range":"250°C to 750°C","cmc":"0,7 °C"}],"reference_cs":"PT5 na základě EURAMET cg-11 v. 2.0","regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Ukazatele (měřidla) teploty pracující s odporovými snímači Kalibrace — Elektrická simulace veličin Vnitřní postup; Nepřímá/přímá metoda; Mimo stálou lokalitu (P) Elektrická simulace veličin Vnitřní postup Nepřímá/přímá metoda Mimo stálou lokalitu (P) PT5 na základě EURAMET cg-11 v. 2.0","technique_cs":"Vnitřní postup; Nepřímá/přímá metoda; Mimo stálou lokalitu (P)","techniques_cs":["Vnitřní postup","Nepřímá/přímá metoda","Mimo stálou lokalitu (P)"],"test_object_cs":"Ukazatele (měřidla) teploty pracující s odporovými snímači"},{"_id":"5994b381a709688d6b4e65cf","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Przetworniki temperatury (współpracujące z czujnikami termoelektrycznymi)","test_object_en":"Temperature transmitters (cooperating with thermoelectric sensors)","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"","range":"-25 °C do 0 °C","cmc":"0,15 °C"},{"name":"","range":"0 °C do 200 °C","cmc":"0,23 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,5 °C"},{"name":"","range":"400 °C do 600 °C","cmc":"0,8 °C"},{"name":"","range":"600 °C do 1200 °C","cmc":"1,2 °C"}],"parameters_en":[{"name":"","range":"-25 °C do 0 °C","cmc":"0,15 °C"},{"name":"","range":"0 °C do 200 °C","cmc":"0,23 °C"},{"name":"","range":"200 °C to 400 °C","cmc":"0,5 °C"},{"name":"","range":"400 °C do 600 °C","cmc":"0,8 °C"},{"name":"","range":"600 °C do 1200 °C","cmc":"1,2 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-25 °C do 0 °C CMC 0,15 °C\n0 °C do 200 °C CMC 0,23 °C\n200 °C do 400 °C CMC 0,5 °C\n400 °C do 600 °C CMC 0,8 °C\n600 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"PT 16","norm_bases":["PT 16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przetworniki temperatury (współpracujące z czujnikami termoelektrycznymi) Wzorcowanie — Elektryczna symulacja wielkości\nZakres:\n-25 °C do 0 °C CMC 0,15 °C\n0 °C do 200 °C CMC 0,23 °C\n200 °C do 400 °C CMC 0,5 °C\n400 °C do 600 °C CMC 0,8 °C\n600 °C do 1200 °C CMC 1,2 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) PT 16 Przetworniki temperatury (wspolpracujace z czujnikami termoelektrycznymi) Wzorcowanie — Elektryczna symulacja wielkosci\nZakres:\n-25 °C do 0 °C CMC 0,15 °C\n0 °C do 200 °C CMC 0,23 °C\n200 °C do 400 °C CMC 0,5 °C\n400 °C do 600 °C CMC 0,8 °C\n600 °C do 1200 °C CMC 1,2 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) PT 16","search_en":"Temperature transmitters (cooperating with thermoelectric sensors) Calibration — Electric quantity simulation Internal procedure; Indirect method; At permanent location (S) Electric quantity simulation Internal procedure Indirect method At permanent location (S) PT 16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":8,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-25 °C do 0 °C","cmc":"0,15 °C"},{"name":"","range":"0 °C do 200 °C","cmc":"0,23 °C"},{"name":"","range":"200 °C bis 400 °C","cmc":"0,5 °C"},{"name":"","range":"400 °C do 600 °C","cmc":"0,8 °C"},{"name":"","range":"600 °C do 1200 °C","cmc":"1,2 °C"}],"regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturmessumformer (für Thermoelemente) Kalibrierung — Elektrische Simulation von Größen Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Elektrische Simulation von Größen Internes Verfahren Indirektes Verfahren Am festen Standort (S) PT 16","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturmessumformer (für Thermoelemente)","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-25 °C do 0 °C","cmc":"0,15 °C"},{"name":"","range":"0 °C do 200 °C","cmc":"0,23 °C"},{"name":"","range":"200 °C 至 400 °C","cmc":"0,5 °C"},{"name":"","range":"400 °C do 600 °C","cmc":"0,8 °C"},{"name":"","range":"600 °C do 1200 °C","cmc":"1,2 °C"}],"regulatory_area_zh":"量值的电模拟","search_zh":"温度变送器（配热电偶） 校准 — 物理量的电模拟 内部程序；间接方法；固定地点（S） 量值的电模拟 内部程序 间接法 在固定地点 (S) PT 16","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"温度变送器（配热电偶）","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-25 °C do 0 °C","cmc":"0,15 °C"},{"name":"","range":"0 °C do 200 °C","cmc":"0,23 °C"},{"name":"","range":"200 °C do 400 °C","cmc":"0,5 °C"},{"name":"","range":"400 °C do 600 °C","cmc":"0,8 °C"},{"name":"","range":"600 °C do 1200 °C","cmc":"1,2 °C"}],"regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Převodníky teploty (spolupracující s termoelektrickými snímači) Kalibrace — Elektrická simulace veličin Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Elektrická simulace veličin Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) PT 16","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Převodníky teploty (spolupracující s termoelektrickými snímači)"},{"_id":"da510f85e967223bc765111b","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Przetworniki temperatury (współpracujące z czujnikami rezystancyjnymi)","test_object_en":"Temperature transmitters (cooperating with resistance sensors)","methodology":"Wzorcowanie — Elektryczna symulacja wielkości","methodology_en":"Calibration — Electric quantity simulation","parameters":[{"name":"","range":"-50 °C do 850 °C","cmc":"0,14 °C"}],"parameters_en":[{"name":"","range":"-50 °C to 850 °C","cmc":"0,14 °C"}],"technique":"Procedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","technique_en":"Internal procedure; Indirect method; At permanent location (S)","techniques":["Procedura wewnętrzna","Metoda pośrednia","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","Indirect method","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Elektryczna symulacja wielkości\n-50 °C do 850 °C CMC 0,14 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S)","reference":"PT 16","norm_bases":["PT 16"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Elektryczna symulacja wielkości","regulatory_area_en":"Electric quantity simulation","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Przetworniki temperatury (współpracujące z czujnikami rezystancyjnymi) Wzorcowanie — Elektryczna symulacja wielkości\n-50 °C do 850 °C CMC 0,14 °C\nProcedura wewnętrzna; Metoda pośrednia; W stałej lokalizacji (S) PT 16 Przetworniki temperatury (wspolpracujace z czujnikami rezystancyjnymi) Wzorcowanie — Elektryczna symulacja wielkosci\n-50 °C do 850 °C CMC 0,14 °C\nProcedura wewnetrzna; Metoda posrednia; W stalej lokalizacji (S) PT 16","search_en":"Temperature transmitters (cooperating with resistance sensors) Calibration — Electric quantity simulation Internal procedure; Indirect method; At permanent location (S) Electric quantity simulation Internal procedure Indirect method At permanent location (S) PT 16","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":9,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Elektrische Simulation von Größen","parameters_de":[{"name":"","range":"-50 °C to 850 °C","cmc":"0,14 °C"}],"regulatory_area_de":"Elektrische Simulation von Größen","search_de":"Temperaturtransmitter (mit Widerstandssensoren) Kalibrierung — Elektrische Simulation von Größen Interne Prozedur; Indirektes Verfahren; An festem Standort (S) Elektrische Simulation von Größen Internes Verfahren Indirektes Verfahren Am festen Standort (S) PT 16","technique_de":"Interne Prozedur; Indirektes Verfahren; An festem Standort (S)","techniques_de":["Internes Verfahren","Indirektes Verfahren","Am festen Standort (S)"],"test_object_de":"Temperaturtransmitter (mit Widerstandssensoren)","methodology_zh":"校准 — 物理量的电模拟","parameters_zh":[{"name":"","range":"-50 °C to 850 °C","cmc":"0,14 °C"}],"regulatory_area_zh":"量值的电模拟","search_zh":"温度变送器（配电阻传感器） 校准 — 物理量的电模拟 内部程序；间接方法；固定地点（S） 量值的电模拟 内部程序 间接法 在固定地点 (S) PT 16","technique_zh":"内部程序；间接方法；固定地点（S）","techniques_zh":["内部程序","间接法","在固定地点 (S)"],"test_object_zh":"温度变送器（配电阻传感器）","methodology_cs":"Kalibrace — Elektrická simulace veličin","parameters_cs":[{"name":"","range":"-50 °C to 850 °C","cmc":"0,14 °C"}],"regulatory_area_cs":"Elektrická simulace veličin","search_cs":"Převodníky teploty (spolupracující s odporovými snímači) Kalibrace — Elektrická simulace veličin Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S) Elektrická simulace veličin Vnitřní postup Nepřímá metoda Ve stálé lokalitě (S) PT 16","technique_cs":"Vnitřní postup; Nepřímá metoda; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Nepřímá metoda","Ve stálé lokalitě (S)"],"test_object_cs":"Převodníky teploty (spolupracující s odporovými snímači)"},{"_id":"395ee1dc2179306e4f086df8","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe\nPrzetworniki ciśnienia","test_object_en":"Electronic pressure gauges\nSpring pressure gauges\nPressure transducers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne (czynnik gaz)","range":"-100 kPa do -20 kPa","cmc":"0,2 kPa"},{"name":"- ciśnienie względne (czynnik gaz)","range":"-20 kPa do 20 kPa","cmc":"0,02 kPa"},{"name":"- ciśnienie względne (czynnik gaz)","range":"20 kPa do 200 kPa","cmc":"0,2 kPa"},{"name":"- ciśnienie względne (czynnik gaz)","range":"200 kPa do 2000 kPa","cmc":"0,7 kPa"},{"name":"- ciśnienie względne (czynnik gaz)","range":"2000 kPa do 3500 kPa","cmc":"5 kPa"}],"parameters_en":[{"name":"relative pressure (gas medium)","range":"-100 kPa to -20 kPa","cmc":"0,2 kPa"},{"name":"relative pressure (gas medium)","range":"-20 kPa to 20 kPa","cmc":"0,02 kPa"},{"name":"relative pressure (gas medium)","range":"20 kPa to 200 kPa","cmc":"0,2 kPa"},{"name":"relative pressure (gas medium)","range":"200 kPa to 2000 kPa","cmc":"0,7 kPa"},{"name":"relative pressure (gas medium)","range":"2000 kPa to 3500 kPa","cmc":"5 kPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik gaz) -100 kPa do -20 kPa CMC 0,2 kPa\n- ciśnienie względne (czynnik gaz) -20 kPa do 20 kPa CMC 0,02 kPa\n- ciśnienie względne (czynnik gaz) 20 kPa do 200 kPa CMC 0,2 kPa\n- ciśnienie względne (czynnik gaz) 200 kPa do 2000 kPa CMC 0,7 kPa\n- ciśnienie względne (czynnik gaz) 2000 kPa do 3500 kPa CMC 5 kPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT6, PT14, PT17 w oparciu o EURAMET cg-17 v. 4.1","norm_bases":["PT6","PT14","PT17","EURAMET cg-17 v. 4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe\nPrzetworniki ciśnienia Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik gaz) -100 kPa do -20 kPa CMC 0,2 kPa\n- ciśnienie względne (czynnik gaz) -20 kPa do 20 kPa CMC 0,02 kPa\n- ciśnienie względne (czynnik gaz) 20 kPa do 200 kPa CMC 0,2 kPa\n- ciśnienie względne (czynnik gaz) 200 kPa do 2000 kPa CMC 0,7 kPa\n- ciśnienie względne (czynnik gaz) 2000 kPa do 3500 kPa CMC 5 kPa\nProcedura wewnętrzna; W stałej lokalizacji (S) PT6, PT14, PT17 w oparciu o EURAMET cg-17 v. 4.1 Cisnieniomierze elektroniczne\nCisnieniomierze sprezynowe\nPrzetworniki cisnienia Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne (czynnik gaz) -100 kPa do -20 kPa CMC 0,2 kPa\n- cisnienie wzgledne (czynnik gaz) -20 kPa do 20 kPa CMC 0,02 kPa\n- cisnienie wzgledne (czynnik gaz) 20 kPa do 200 kPa CMC 0,2 kPa\n- cisnienie wzgledne (czynnik gaz) 200 kPa do 2000 kPa CMC 0,7 kPa\n- cisnienie wzgledne (czynnik gaz) 2000 kPa do 3500 kPa CMC 5 kPa\nProcedura wewnetrzna; W stalej lokalizacji (S) PT6, PT14, PT17 w oparciu o EURAMET cg-17 v. 4.1","search_en":"Electronic pressure gauges Spring pressure gauges Pressure transducers Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) relative pressure (gas medium) relative pressure (gas medium) relative pressure (gas medium) relative pressure (gas medium) relative pressure (gas medium) PT6, PT14, PT17 based on EURAMET cg-17 v. 4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":10,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT6, PT14, PT17 based on EURAMET cg-17 v. 4.1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Überdruck (Medium Gas)","range":"-100 kPa to -20 kPa","cmc":"0,2 kPa"},{"name":"- Überdruck (Medium Gas)","range":"-20 kPa to 20 kPa","cmc":"0,02 kPa"},{"name":"- Überdruck (Medium Gas)","range":"20 kPa to 200 kPa","cmc":"0,2 kPa"},{"name":"- Überdruck (Medium Gas)","range":"200 kPa to 2000 kPa","cmc":"0,7 kPa"},{"name":"- Überdruck (Medium Gas)","range":"2000 kPa to 3500 kPa","cmc":"5 kPa"}],"reference_de":"PT6, PT14, PT17 auf Grundlage von EURAMET cg-17 v. 4.1","regulatory_area_de":"Druck","search_de":"Elektronische Druckmessgeräte Federmanometer Druckmessumformer Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) - Überdruck (Medium Gas) - Überdruck (Medium Gas) - Überdruck (Medium Gas) - Überdruck (Medium Gas) - Überdruck (Medium Gas) PT6, PT14, PT17 auf Grundlage von EURAMET cg-17 v. 4.1","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektronische Druckmessgeräte\nFedermanometer\nDruckmessumformer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压（介质为气体）","range":"-100 kPa to -20 kPa","cmc":"0,2 kPa"},{"name":"- 表压（介质为气体）","range":"-20 kPa to 20 kPa","cmc":"0,02 kPa"},{"name":"- 表压（介质为气体）","range":"20 kPa to 200 kPa","cmc":"0,2 kPa"},{"name":"- 表压（介质为气体）","range":"200 kPa to 2000 kPa","cmc":"0,7 kPa"},{"name":"- 表压（介质为气体）","range":"2000 kPa to 3500 kPa","cmc":"5 kPa"}],"reference_zh":"PT6, PT14, PT17 依据EURAMET cg-17 v. 4.1","regulatory_area_zh":"压力","search_zh":"电子压力计 弹簧管压力表 压力变送器 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) - 表压（介质为气体） - 表压（介质为气体） - 表压（介质为气体） - 表压（介质为气体） - 表压（介质为气体） PT6, PT14, PT17 依据EURAMET cg-17 v. 4.1","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电子压力计\n弹簧管压力表\n压力变送器","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak (médium plyn)","range":"-100 kPa to -20 kPa","cmc":"0,2 kPa"},{"name":"- přetlak (médium plyn)","range":"-20 kPa to 20 kPa","cmc":"0,02 kPa"},{"name":"- přetlak (médium plyn)","range":"20 kPa to 200 kPa","cmc":"0,2 kPa"},{"name":"- přetlak (médium plyn)","range":"200 kPa to 2000 kPa","cmc":"0,7 kPa"},{"name":"- přetlak (médium plyn)","range":"2000 kPa to 3500 kPa","cmc":"5 kPa"}],"reference_cs":"PT6, PT14, PT17 na základě EURAMET cg-17 v. 4.1","regulatory_area_cs":"Tlak","search_cs":"Elektronické tlakoměry Deformační tlakoměry Převodníky tlaku Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) - přetlak (médium plyn) - přetlak (médium plyn) - přetlak (médium plyn) - přetlak (médium plyn) - přetlak (médium plyn) PT6, PT14, PT17 na základě EURAMET cg-17 v. 4.1","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Elektronické tlakoměry\nDeformační tlakoměry\nPřevodníky tlaku"},{"_id":"fa69eeb22ef520d7c4e975a3","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe\nPrzetworniki ciśnienia","test_object_en":"Electronic pressure gauges\nSpring pressure gauges\nPressure transducers","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne (czynnik ciecz)","range":"0 MPa do 10 MPa","cmc":"7,8 · 10⁻⁴ · p"},{"name":"- ciśnienie względne (czynnik ciecz)","range":"10 MPa do 25 MPa","cmc":"0,02 MPa"},{"name":"- ciśnienie względne (czynnik ciecz)","range":"25 MPa do 40 MPa","cmc":"0,03 MPa"}],"parameters_en":[{"name":"relative pressure (liquid medium)","range":"0 MPa to 10 MPa","cmc":"7,8 · 10⁻⁴ · p"},{"name":"relative pressure (liquid medium)","range":"10 MPa to 25 MPa","cmc":"0,02 MPa"},{"name":"relative pressure (liquid medium)","range":"25 MPa to 40 MPa","cmc":"0,03 MPa"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik ciecz) 0 MPa do 10 MPa CMC 7,8 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 10 MPa do 25 MPa CMC 0,02 MPa\n- ciśnienie względne (czynnik ciecz) 25 MPa do 40 MPa CMC 0,03 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT6, PT14, PT17 w oparciu o EURAMET cg-17 v. 4.1","norm_bases":["PT6","PT14","PT17","EURAMET cg-17 v. 4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":false,"location_of_activity":"S","note":"p - wielkość mierzona (Pa)","note_en":"p - measured value (Pa)","search_text":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe\nPrzetworniki ciśnienia Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik ciecz) 0 MPa do 10 MPa CMC 7,8 · 10⁻⁴ · p\n- ciśnienie względne (czynnik ciecz) 10 MPa do 25 MPa CMC 0,02 MPa\n- ciśnienie względne (czynnik ciecz) 25 MPa do 40 MPa CMC 0,03 MPa\nProcedura wewnętrzna; W stałej lokalizacji (S) PT6, PT14, PT17 w oparciu o EURAMET cg-17 v. 4.1 Cisnieniomierze elektroniczne\nCisnieniomierze sprezynowe\nPrzetworniki cisnienia Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne (czynnik ciecz) 0 MPa do 10 MPa CMC 7,8 · 10⁻⁴ · p\n- cisnienie wzgledne (czynnik ciecz) 10 MPa do 25 MPa CMC 0,02 MPa\n- cisnienie wzgledne (czynnik ciecz) 25 MPa do 40 MPa CMC 0,03 MPa\nProcedura wewnetrzna; W stalej lokalizacji (S) PT6, PT14, PT17 w oparciu o EURAMET cg-17 v. 4.1","search_en":"Electronic pressure gauges Spring pressure gauges Pressure transducers Calibration — Pressure Internal procedure; At permanent location (S) Pressure Internal procedure At permanent location (S) relative pressure (liquid medium) relative pressure (liquid medium) relative pressure (liquid medium) PT6, PT14, PT17 based on EURAMET cg-17 v. 4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":11,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT6, PT14, PT17 based on EURAMET cg-17 v. 4.1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Überdruck (Medium Flüssigkeit)","range":"0 MPa to 10 MPa","cmc":"7,8 · 10⁻⁴ · p"},{"name":"- Überdruck (Medium Flüssigkeit)","range":"10 MPa to 25 MPa","cmc":"0,02 MPa"},{"name":"- Überdruck (Medium Flüssigkeit)","range":"25 MPa to 40 MPa","cmc":"0,03 MPa"}],"reference_de":"PT6, PT14, PT17 auf Grundlage von EURAMET cg-17 v. 4.1","regulatory_area_de":"Druck","search_de":"Elektronische Druckmessgeräte Federmanometer Druckmessumformer Kalibrierung — Druck Internes Verfahren; Am festen Standort (S) Druck Internes Verfahren Am festen Standort (S) - Überdruck (Medium Flüssigkeit) - Überdruck (Medium Flüssigkeit) - Überdruck (Medium Flüssigkeit) PT6, PT14, PT17 auf Grundlage von EURAMET cg-17 v. 4.1","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektronische Druckmessgeräte\nFedermanometer\nDruckmessumformer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压（介质 液体）","range":"0 MPa to 10 MPa","cmc":"7,8 · 10⁻⁴ · p"},{"name":"- 表压（介质 液体）","range":"10 MPa to 25 MPa","cmc":"0,02 MPa"},{"name":"- 表压（介质 液体）","range":"25 MPa to 40 MPa","cmc":"0,03 MPa"}],"reference_zh":"PT6, PT14, PT17 依据EURAMET cg-17 v. 4.1","regulatory_area_zh":"压力","search_zh":"电子压力计 弹簧管压力表 压力变送器 校准 — 压力 内部程序；在固定地点 (S) 压力 内部程序 在固定地点 (S) - 表压（介质 液体） - 表压（介质 液体） - 表压（介质 液体） PT6, PT14, PT17 依据EURAMET cg-17 v. 4.1","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电子压力计\n弹簧管压力表\n压力变送器","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak (médium kapalina)","range":"0 MPa to 10 MPa","cmc":"7,8 · 10⁻⁴ · p"},{"name":"- přetlak (médium kapalina)","range":"10 MPa to 25 MPa","cmc":"0,02 MPa"},{"name":"- přetlak (médium kapalina)","range":"25 MPa to 40 MPa","cmc":"0,03 MPa"}],"reference_cs":"PT6, PT14, PT17 na základě EURAMET cg-17 v. 4.1","regulatory_area_cs":"Tlak","search_cs":"Elektronické tlakoměry Deformační tlakoměry Převodníky tlaku Kalibrace — Tlak Vnitřní postup; Ve stálé lokalitě (S) Tlak Vnitřní postup Ve stálé lokalitě (S) - přetlak (médium kapalina) - přetlak (médium kapalina) - přetlak (médium kapalina) PT6, PT14, PT17 na základě EURAMET cg-17 v. 4.1","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Elektronické tlakoměry\nDeformační tlakoměry\nPřevodníky tlaku"},{"_id":"2782c3ccaee224b9ba349ef9","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe","test_object_en":"Electronic pressure gauges\nSpring pressure gauges","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne (czynnik gaz)","range":"-100 kPa do 2000 kPa","cmc":"1,3 kPa"}],"parameters_en":[{"name":"relative pressure (gas medium)","range":"-100 kPa to 2000 kPa","cmc":"1,3 kPa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\n- ciśnienie względne (czynnik gaz) -100 kPa do 2000 kPa CMC 1,3 kPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PT6 w oparciu o EURAMET cg-17 v.4.1","norm_bases":["PT6","EURAMET cg-17 v.4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe Wzorcowanie — Ciśnienie\n- ciśnienie względne (czynnik gaz) -100 kPa do 2000 kPa CMC 1,3 kPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PT6 w oparciu o EURAMET cg-17 v.4.1 Cisnieniomierze elektroniczne\nCisnieniomierze sprezynowe Wzorcowanie — Cisnienie\n- cisnienie wzgledne (czynnik gaz) -100 kPa do 2000 kPa CMC 1,3 kPa\nProcedura wewnetrzna; Poza stala lokalizacja (P) PT6 w oparciu o EURAMET cg-17 v.4.1","search_en":"Electronic pressure gauges Spring pressure gauges Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) relative pressure (gas medium) PT6 based on EURAMET cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":12,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT6 based on EURAMET cg-17 v.4.1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Überdruck (Medium Gas)","range":"-100 kPa to 2000 kPa","cmc":"1,3 kPa"}],"reference_de":"PT6 auf Grundlage von EURAMET cg-17 v.4.1","regulatory_area_de":"Druck","search_de":"Elektronische Druckmessgeräte Federmanometer Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) - Überdruck (Medium Gas) PT6 auf Grundlage von EURAMET cg-17 v.4.1","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Elektronische Druckmessgeräte\nFedermanometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压（介质为气体）","range":"-100 kPa to 2000 kPa","cmc":"1,3 kPa"}],"reference_zh":"PT6 依据EURAMET cg-17 v.4.1","regulatory_area_zh":"压力","search_zh":"电子压力计 弹簧管压力表 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) - 表压（介质为气体） PT6 依据EURAMET cg-17 v.4.1","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"电子压力计\n弹簧管压力表","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak (médium plyn)","range":"-100 kPa to 2000 kPa","cmc":"1,3 kPa"}],"reference_cs":"PT6 na základě EURAMET cg-17 v.4.1","regulatory_area_cs":"Tlak","search_cs":"Elektronické tlakoměry Deformační tlakoměry Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) - přetlak (médium plyn) PT6 na základě EURAMET cg-17 v.4.1","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Elektronické tlakoměry\nDeformační tlakoměry"},{"_id":"260d54a72f74b456fd129b06","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe","test_object_en":"Electronic pressure gauges\nSpring pressure gauges","methodology":"Wzorcowanie — Ciśnienie","methodology_en":"Calibration — Pressure","parameters":[{"name":"- ciśnienie względne (czynnik ciecz)","range":"0 kPa do 2000 kPa","cmc":"1,3 kPa"},{"name":"- ciśnienie względne (czynnik ciecz)","range":"2 MPa do 40 MPa","cmc":"0,03 MPa"}],"parameters_en":[{"name":"relative pressure (liquid medium)","range":"0 kPa to 2000 kPa","cmc":"1,3 kPa"},{"name":"relative pressure (liquid medium)","range":"2 MPa to 40 MPa","cmc":"0,03 MPa"}],"technique":"Procedura wewnętrzna; Poza stałą lokalizacją (P)","technique_en":"Internal procedure; Outside of permanent location (P)","techniques":["Procedura wewnętrzna","Poza stałą lokalizacją (P)"],"techniques_en":["Internal procedure","Outside of permanent location (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik ciecz) 0 kPa do 2000 kPa CMC 1,3 kPa\n- ciśnienie względne (czynnik ciecz) 2 MPa do 40 MPa CMC 0,03 MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P)","reference":"PT6 w oparciu o EURAMET cg-17 v.4.1","norm_bases":["PT6","EURAMET cg-17 v.4.1"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Ciśnienie","regulatory_area_en":"Pressure","outside_premises":true,"location_of_activity":"P","note":null,"note_en":null,"search_text":"Ciśnieniomierze elektroniczne\nCiśnieniomierze sprężynowe Wzorcowanie — Ciśnienie\nZakres:\n- ciśnienie względne (czynnik ciecz) 0 kPa do 2000 kPa CMC 1,3 kPa\n- ciśnienie względne (czynnik ciecz) 2 MPa do 40 MPa CMC 0,03 MPa\nProcedura wewnętrzna; Poza stałą lokalizacją (P) PT6 w oparciu o EURAMET cg-17 v.4.1 Cisnieniomierze elektroniczne\nCisnieniomierze sprezynowe Wzorcowanie — Cisnienie\nZakres:\n- cisnienie wzgledne (czynnik ciecz) 0 kPa do 2000 kPa CMC 1,3 kPa\n- cisnienie wzgledne (czynnik ciecz) 2 MPa do 40 MPa CMC 0,03 MPa\nProcedura wewnetrzna; Poza stala lokalizacja (P) PT6 w oparciu o EURAMET cg-17 v.4.1","search_en":"Electronic pressure gauges Spring pressure gauges Calibration — Pressure Internal procedure; Outside of permanent location (P) Pressure Internal procedure Outside of permanent location (P) relative pressure (liquid medium) relative pressure (liquid medium) PT6 based on EURAMET cg-17 v.4.1","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":13,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","reference_en":"PT6 based on EURAMET cg-17 v.4.1","methodology_de":"Kalibrierung — Druck","parameters_de":[{"name":"- Überdruck (Medium Flüssigkeit)","range":"0 kPa bis 2000 kPa","cmc":"1,3 kPa"},{"name":"- Überdruck (Medium Flüssigkeit)","range":"2 MPa to 40 MPa","cmc":"0,03 MPa"}],"reference_de":"PT6 auf Grundlage von EURAMET cg-17 v.4.1","regulatory_area_de":"Druck","search_de":"Elektronische Druckmessgeräte Federmanometer Kalibrierung — Druck Interne Verfahrensanweisung; Außerhalb des festen Standorts (P) Druck Internes Verfahren Außerhalb des festen Standorts (P) - Überdruck (Medium Flüssigkeit) - Überdruck (Medium Flüssigkeit) PT6 auf Grundlage von EURAMET cg-17 v.4.1","technique_de":"Interne Verfahrensanweisung; Außerhalb des festen Standorts (P)","techniques_de":["Internes Verfahren","Außerhalb des festen Standorts (P)"],"test_object_de":"Elektronische Druckmessgeräte\nFedermanometer","methodology_zh":"校准 — 压力","parameters_zh":[{"name":"- 表压（介质 液体）","range":"0 kPa 至 2000 kPa","cmc":"1,3 kPa"},{"name":"- 表压（介质 液体）","range":"2 MPa to 40 MPa","cmc":"0,03 MPa"}],"reference_zh":"PT6 依据EURAMET cg-17 v.4.1","regulatory_area_zh":"压力","search_zh":"电子压力计 弹簧管压力表 校准 — 压力 内部程序；固定地点以外 (P) 压力 内部程序 固定地点以外 (P) - 表压（介质 液体） - 表压（介质 液体） PT6 依据EURAMET cg-17 v.4.1","technique_zh":"内部程序；固定地点以外 (P)","techniques_zh":["内部程序","固定地点以外 (P)"],"test_object_zh":"电子压力计\n弹簧管压力表","methodology_cs":"Kalibrace — Tlak","parameters_cs":[{"name":"- přetlak (médium kapalina)","range":"0 kPa do 2000 kPa","cmc":"1,3 kPa"},{"name":"- přetlak (médium kapalina)","range":"2 MPa to 40 MPa","cmc":"0,03 MPa"}],"reference_cs":"PT6 na základě EURAMET cg-17 v.4.1","regulatory_area_cs":"Tlak","search_cs":"Elektronické tlakoměry Deformační tlakoměry Kalibrace — Tlak Vnitřní postup; Mimo stálé pracoviště (P) Tlak Vnitřní postup Mimo stálou lokalitu (P) - přetlak (médium kapalina) - přetlak (médium kapalina) PT6 na základě EURAMET cg-17 v.4.1","technique_cs":"Vnitřní postup; Mimo stálé pracoviště (P)","techniques_cs":["Vnitřní postup","Mimo stálou lokalitu (P)"],"test_object_cs":"Elektronické tlakoměry\nDeformační tlakoměry"},{"_id":"726471fc24afe6929f53bd4f","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Termometry elektryczne (w tym elektroniczne)","test_object_en":"Electric thermometers (including electronic)","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-100 °C do -40 °C","cmc":"0,37 °C"},{"name":"","range":"-40 °C do 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C do 650 °C","cmc":"0,14 °C"},{"name":"","range":"650 °C do 1100 °C","cmc":"0,9 °C"}],"parameters_en":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"-40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,14 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,9 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,37 °C\n-40 °C do 155 °C CMC 0,04 °C\n155 °C do 650 °C CMC 0,14 °C\n650 °C do 1100 °C CMC 0,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT18","norm_bases":["PT18"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,37 °C\n-40 °C do 155 °C CMC 0,04 °C\n155 °C do 650 °C CMC 0,14 °C\n650 °C do 1100 °C CMC 0,9 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PT18 Termometry elektryczne (w tym elektroniczne) Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,37 °C\n-40 °C do 155 °C CMC 0,04 °C\n155 °C do 650 °C CMC 0,14 °C\n650 °C do 1100 °C CMC 0,9 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PT18","search_en":"Electric thermometers (including electronic) Calibration — Temperature (electric thermometry) Internal procedure; At permanent location (S) Temperature (electric thermometry) Internal procedure At permanent location (S) PT18","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":14,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"-40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,14 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,9 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Elektrische Thermometer (einschließlich elektronischer) Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PT18","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Elektrische Thermometer (einschließlich elektronischer)","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"-40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,14 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,9 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电测温度计（包括电子温度计） 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PT18","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电测温度计（包括电子温度计）","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"-40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,14 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,9 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Elektrické teploměry (včetně elektronických) Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PT18","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Elektrické teploměry (včetně elektronických)"},{"_id":"3cd535af9abfb5e072c12600","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych","test_object_en":"Precious metal thermoelectric sensors\nBase metal thermoelectric sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"0 °C do 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C do 1100 °C","cmc":"0,8 °C"}],"parameters_en":[{"name":"","range":"0 °C to 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,8 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 650 °C CMC 0,7 °C\n650 °C do 1100 °C CMC 0,8 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT12","norm_bases":["PT12"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 650 °C CMC 0,7 °C\n650 °C do 1100 °C CMC 0,8 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PT12 Czujniki termoelektryczne z metali szlachetnych\nCzujniki termoelektryczne z metali nieszlachetnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n0 °C do 650 °C CMC 0,7 °C\n650 °C do 1100 °C CMC 0,8 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PT12","search_en":"Precious metal thermoelectric sensors Base metal thermoelectric sensors Calibration — Temperature (electric thermometry) Internal procedure; At permanent location (S) Temperature (electric thermometry) Internal procedure At permanent location (S) PT12","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":15,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C to 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,8 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Edelmetall-Thermoelemente Thermoelemente aus unedlen Metallen Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PT12","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Edelmetall-Thermoelemente\nThermoelemente aus unedlen Metallen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"0 °C to 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,8 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"贵金属热电偶 贱金属热电偶传感器 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PT12","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"贵金属热电偶\n贱金属热电偶传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C to 650 °C","cmc":"0,7 °C"},{"name":"","range":"650 °C to 1100 °C","cmc":"0,8 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termoelektrické snímače z drahých kovů Termoelektrické snímače z obecných kovů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PT12","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Termoelektrické snímače z drahých kovů\nTermoelektrické snímače z obecných kovů"},{"_id":"b42902b0ec53ef69f1f6eb90","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Czujniki termometrów rezystancyjnych","test_object_en":"Resistance thermometer sensors","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-100 °C do -40 °C","cmc":"0,37 °C"},{"name":"","range":"- 40 °C do 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C do 650 °C","cmc":"0,13 °C"}],"parameters_en":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"- 40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,13 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,37 °C\n- 40 °C do 155 °C CMC 0,04 °C\n155 °C do 650 °C CMC 0,13 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT11","norm_bases":["PT11"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Czujniki termometrów rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,37 °C\n- 40 °C do 155 °C CMC 0,04 °C\n155 °C do 650 °C CMC 0,13 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PT11 Czujniki termometrow rezystancyjnych Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,37 °C\n- 40 °C do 155 °C CMC 0,04 °C\n155 °C do 650 °C CMC 0,13 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PT11","search_en":"Resistance thermometer sensors Calibration — Temperature (electric thermometry) Internal procedure; At permanent location (S) Temperature (electric thermometry) Internal procedure At permanent location (S) PT11","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":16,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"- 40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,13 °C"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Fühler von Widerstandsthermometern Kalibrierung — Temperatur (elektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) PT11","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Fühler von Widerstandsthermometern","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"- 40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,13 °C"}],"regulatory_area_zh":"温度（电测温）","search_zh":"电阻温度计传感器 校准 — 温度（电测温） 内部程序；在固定地点 (S) 温度（电测温） 内部程序 在固定地点 (S) PT11","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"电阻温度计传感器","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,37 °C"},{"name":"","range":"- 40 °C to 155 °C","cmc":"0,04 °C"},{"name":"","range":"155 °C to 650 °C","cmc":"0,13 °C"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Čidla odporových teploměrů Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (elektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PT11","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Čidla odporových teploměrů"},{"_id":"a9a6a377e6db2c3e9d496675","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Komory termostatyczne\nPiece","test_object_en":"Thermostatic chambers\nFurnaces","methodology":"Wzorcowanie — Temperatura (termometria elektryczna)","methodology_en":"Calibration — Temperature (electric thermometry)","parameters":[{"name":"","range":"-100 °C do -40 °C","cmc":"0,5 °C1)"},{"name":"","range":"-40 °C do 250 °C","cmc":"0,4 °C1)"},{"name":"","range":"250 °C do 650 °C","cmc":"1,0 °C1)"},{"name":"","range":"650 °C do 1100 °C","cmc":"1,1 °C1)"}],"parameters_en":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,5 °C1)"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,4 °C1)"},{"name":"","range":"250 °C to 650 °C","cmc":"1,0 °C1)"},{"name":"","range":"650 °C to 1100 °C","cmc":"1,1 °C1)"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","technique_en":"Internal procedure; At permanent location (S) and outside of it (P)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S) i poza nią (P)"],"techniques_en":["Internal procedure","At permanent location (S) and outside of it (P)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,5 °C1)\n-40 °C do 250 °C CMC 0,4 °C1)\n250 °C do 650 °C CMC 1,0 °C1)\n650 °C do 1100 °C CMC 1,1 °C1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P)","reference":"PT 19","norm_bases":["PT 19"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria elektryczna)","regulatory_area_en":"Temperature (electric thermometry)","outside_premises":true,"location_of_activity":"S, P","note":"1) Wartość CMC dotyczy punktowego pomiaru temperatury w komorze wzorcowanego obiektu","note_en":"1) The CMC value relates to a point temperature measurement within the chamber of the calibrated object","search_text":"Komory termostatyczne\nPiece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,5 °C1)\n-40 °C do 250 °C CMC 0,4 °C1)\n250 °C do 650 °C CMC 1,0 °C1)\n650 °C do 1100 °C CMC 1,1 °C1)\nProcedura wewnętrzna; W stałej lokalizacji (S) i poza nią (P) PT 19 Komory termostatyczne\nPiece Wzorcowanie — Temperatura (termometria elektryczna)\nZakres:\n-100 °C do -40 °C CMC 0,5 °C1)\n-40 °C do 250 °C CMC 0,4 °C1)\n250 °C do 650 °C CMC 1,0 °C1)\n650 °C do 1100 °C CMC 1,1 °C1)\nProcedura wewnetrzna; W stalej lokalizacji (S) i poza nia (P) PT 19","search_en":"Thermostatic chambers Furnaces Calibration — Temperature (electric thermometry) Internal procedure; At permanent location (S) and outside of it (P) Temperature (electric thermometry) Internal procedure At permanent location (S) and outside of it (P) PT 19","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":17,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (elektrische Thermometrie)","parameters_de":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,5 °C1)"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,4 °C1)"},{"name":"","range":"250 °C to 650 °C","cmc":"1,0 °C1)"},{"name":"","range":"650 °C to 1100 °C","cmc":"1,1 °C1)"}],"regulatory_area_de":"Temperatur (elektrische Thermometrie)","search_de":"Thermostatkammern Öfen Kalibrierung — Temperatur (elektrische Thermometrie) Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P) Temperatur (elektrische Thermometrie) Internes Verfahren Am festen Standort (S) und außerhalb (P) PT 19","technique_de":"Interne Verfahrensanweisung; Am festen Standort (S) und außerhalb (P)","techniques_de":["Internes Verfahren","Am festen Standort (S) und außerhalb (P)"],"test_object_de":"Thermostatkammern\nÖfen","methodology_zh":"校准 — 温度（电测温）","parameters_zh":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,5 °C1)"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,4 °C1)"},{"name":"","range":"250 °C to 650 °C","cmc":"1,0 °C1)"},{"name":"","range":"650 °C to 1100 °C","cmc":"1,1 °C1)"}],"regulatory_area_zh":"温度（电测温）","search_zh":"恒温箱 炉具 校准 — 温度（电测温） 内部程序；在固定地点 (S) 及固定地点以外 (P) 温度（电测温） 内部程序 在固定地点 (S) 及固定地点以外 (P) PT 19","technique_zh":"内部程序；在固定地点 (S) 及固定地点以外 (P)","techniques_zh":["内部程序","在固定地点 (S) 及固定地点以外 (P)"],"test_object_zh":"恒温箱\n炉具","methodology_cs":"Kalibrace — Teplota (elektrická termometrie)","parameters_cs":[{"name":"","range":"-100 °C to -40 °C","cmc":"0,5 °C1)"},{"name":"","range":"-40 °C to 250 °C","cmc":"0,4 °C1)"},{"name":"","range":"250 °C to 650 °C","cmc":"1,0 °C1)"},{"name":"","range":"650 °C to 1100 °C","cmc":"1,1 °C1)"}],"regulatory_area_cs":"Teplota (elektrická termometrie)","search_cs":"Termostatické komory Pece Kalibrace — Teplota (elektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P) Teplota (elektrická termometrie) Vnitřní postup V trvalé lokalitě (S) i mimo ni (P) PT 19","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S) a mimo ni (P)","techniques_cs":["Vnitřní postup","V trvalé lokalitě (S) i mimo ni (P)"],"test_object_cs":"Termostatické komory\nPece"},{"_id":"76ae0a1ebfc0a86eebc3bd78","lab_id":"6afa3b898989a133b76445a8","country":"PL","accr_number":"AP 007","accr_body":"PCA","test_object":"Termometry wskazówkowe","test_object_en":"Dial thermometers","methodology":"Wzorcowanie — Temperatura (termometria nieelektryczna)","methodology_en":"Calibration — Temperature (non-electric thermometry)","parameters":[{"name":"","range":"0 °C do 160 °C","cmc":"0,8 °C"},{"name":"","range":"160 °C do 250 °C","cmc":"2,0 °C"}],"parameters_en":[{"name":"","range":"0 °C to 160 °C","cmc":"0,8 °C"},{"name":"","range":"160 °C to 250 °C","cmc":"2,0 °C"}],"technique":"Procedura wewnętrzna; W stałej lokalizacji (S)","technique_en":"Internal procedure; At permanent location (S)","techniques":["Procedura wewnętrzna","W stałej lokalizacji (S)"],"techniques_en":["Internal procedure","At permanent location (S)"],"computed":[],"computed_en":[],"activity":"Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n0 °C do 160 °C CMC 0,8 °C\n160 °C do 250 °C CMC 2,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S)","reference":"PT13","norm_bases":["PT13"],"internal_procedure":true,"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":"Temperatura (termometria nieelektryczna)","regulatory_area_en":"Temperature (non-electric thermometry)","outside_premises":false,"location_of_activity":"S","note":null,"note_en":null,"search_text":"Termometry wskazówkowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n0 °C do 160 °C CMC 0,8 °C\n160 °C do 250 °C CMC 2,0 °C\nProcedura wewnętrzna; W stałej lokalizacji (S) PT13 Termometry wskazowkowe Wzorcowanie — Temperatura (termometria nieelektryczna)\nZakres:\n0 °C do 160 °C CMC 0,8 °C\n160 °C do 250 °C CMC 2,0 °C\nProcedura wewnetrzna; W stalej lokalizacji (S) PT13","search_en":"Dial thermometers Calibration — Temperature (non-electric thermometry) Internal procedure; At permanent location (S) Temperature (non-electric thermometry) Internal procedure At permanent location (S) PT13","categories":["metrology"],"categories_source":"reczne","source_lang":"pl","translation":{"en":"PCA-oficjalne"},"row_index":18,"parse_version":1,"parse_source":"reczna-analiza-labcoda-1","methodology_de":"Kalibrierung — Temperatur (nichtelektrische Thermometrie)","parameters_de":[{"name":"","range":"0 °C to 160 °C","cmc":"0,8 °C"},{"name":"","range":"160 °C to 250 °C","cmc":"2,0 °C"}],"regulatory_area_de":"Temperatur (nichtelektrische Thermometrie)","search_de":"Zeigerthermometer Kalibrierung — Temperatur (nichtelektrische Thermometrie) Internes Verfahren; Am festen Standort (S) Temperatur (nichtelektrische Thermometrie) Internes Verfahren Am festen Standort (S) PT13","technique_de":"Internes Verfahren; Am festen Standort (S)","techniques_de":["Internes Verfahren","Am festen Standort (S)"],"test_object_de":"Zeigerthermometer","methodology_zh":"校准 — 温度（非电测温）","parameters_zh":[{"name":"","range":"0 °C to 160 °C","cmc":"0,8 °C"},{"name":"","range":"160 °C to 250 °C","cmc":"2,0 °C"}],"regulatory_area_zh":"温度（非电测温）","search_zh":"指针式温度计 校准 — 温度（非电测温） 内部程序；在固定地点 (S) 温度（非电测温） 内部程序 在固定地点 (S) PT13","technique_zh":"内部程序；在固定地点 (S)","techniques_zh":["内部程序","在固定地点 (S)"],"test_object_zh":"指针式温度计","methodology_cs":"Kalibrace — Teplota (neelektrická termometrie)","parameters_cs":[{"name":"","range":"0 °C to 160 °C","cmc":"0,8 °C"},{"name":"","range":"160 °C to 250 °C","cmc":"2,0 °C"}],"regulatory_area_cs":"Teplota (neelektrická termometrie)","search_cs":"Ručkové teploměry Kalibrace — Teplota (neelektrická termometrie) Vnitřní postup; Ve stálé lokalitě (S) Teplota (neelektrická termometrie) Vnitřní postup Ve stálé lokalitě (S) PT13","technique_cs":"Vnitřní postup; Ve stálé lokalitě (S)","techniques_cs":["Vnitřní postup","Ve stálé lokalitě (S)"],"test_object_cs":"Ručkové teploměry"}],"has_pdf":true}