{"lab":{"_id":"69ad52a3de79e566650fb506","accr_number":"AB 998","country":"PL","accr_body":"PCA","address":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI S.A., ul. Partyzancka 27, 63-400 Ostrów Wielkopolski, DZIAŁ LABORATORIUM BADANIA WODY I ŚCIEKÓW, Rąbczyn 118, 63-440 Raszków","categories":["water","microbiology"],"city":"Ostrów Wielkopolski","imported_at":"2026-03-08T10:42:43.265Z","methods_count":32,"name":"WODKAN","parse_status":"parsed","parse_version":3,"pdf_files":["AB_998.pdf"],"scope_summary":"","search_text":"wodkan przedsiębiorstwo wodociągów i kanalizacji s.a., ul. partyzancka 27, 63-400 ostrów wielkopolski, dział laboratorium badania wody i ścieków, rąbczyn 118, 63-440 raszków water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:52.987Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:52.987Z","location":{"type":"Point","coordinates":[17.8067,51.6553]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20998,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage,"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and samling of drinking water"},{"codes":"N/28/P, N/29/P; N/30/P","pl":"Badanie właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"23","date":"22.01.2026"},"parse_date":"2026-07-20T07:09:56.668Z","parse_source":"script-pdfplumber","map_coord":[51.646685,17.810526],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":32,"microbiology":3},"category_scores":{"water":29.26,"microbiology":0.26},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce82601cc","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10+Ap1:2019-07","norm_bases":["PN-ISO 5667-5:2017-10+Ap1:2019-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10+Ap1:2019-07 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10+Ap1:2019-07","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10+Ap1:2019-07","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10+Ap1:2019-07","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a5dc9c4f1c10c8ce82601cd","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,020 − 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 − 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,020 − 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-09 wydanie 8 z dnia 01.09.2020 r. na podstawie testu Merck Nr 1.14752","norm_bases":["PB-09 wydanie 8 z dnia 01.09.2020 r. na podstawie testu Merck Nr 1.14752"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,020 − 2,0) mg/l\nMetoda spektrofotometryczna PB-09 wydanie 8 z dnia 01.09.2020 r. na podstawie testu Merck Nr 1.14752 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,020 − 2,0) mg/l\nMetoda spektrofotometryczna PB-09 wydanie 8 z dnia 01.09.2020 r. na podstawie testu Merck Nr 1.14752","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PB-09 wydanie 8 z dnia 01.09.2020 r. na podstawie testu Merck Nr 1.14752","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,020 − 2,0) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PB-09 wydanie 8 z dnia 01.09.2020 r. na podstawie testu Merck Nr 1.14752","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601ce","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,025 – 0,60) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,025 – 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,025 – 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PB-10 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14776","norm_bases":["PB-10 wydanie 7 z dnia 01.09.2020 r.","na podstawie testu Merck Nr 1.14776"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,025 – 0,60) mg/l\nMetoda spektrofotometryczna PB-10 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14776 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,025 – 0,60) mg/l\nMetoda spektrofotometryczna PB-10 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14776","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PB-10 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14776","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 0,60) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PB-10 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14776","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601cf","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,015 – 2,0)mg/l"}],"parameters_en":[{"name":"Range","range":"(0,015 – 2,0)mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,015 – 2,0)mg/l\nMetoda spektrofotometryczna","reference":"PB-11 wydanie 8 z dnia 03.02.2023 r. | na podstawie testu Merck Nr 1.14770","norm_bases":["PB-11 wydanie 8 z dnia 03.02.2023 r.","na podstawie testu Merck Nr 1.14770"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,015 – 2,0)mg/l\nMetoda spektrofotometryczna PB-11 wydanie 8 z dnia 03.02.2023 r. | na podstawie testu Merck Nr 1.14770 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,015 – 2,0)mg/l\nMetoda spektrofotometryczna PB-11 wydanie 8 z dnia 03.02.2023 r. | na podstawie testu Merck Nr 1.14770","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PB-11 wydanie 8 z dnia 03.02.2023 r. | na podstawie testu Merck Nr 1.14770","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 2,0)mg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PB-11 wydanie 8 z dnia 03.02.2023 r. | na podstawie testu Merck Nr 1.14770","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d0","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(0,02 − 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 − 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (0,02 − 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-12 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14761","norm_bases":["PB-12 wydanie 7 z dnia 01.09.2020 r.","na podstawie testu Merck Nr 1.14761"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,02 − 5,0) mg/l\nMetoda spektrofotometryczna PB-12 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14761 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,02 − 5,0) mg/l\nMetoda spektrofotometryczna PB-12 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14761","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range PB-12 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14761","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 − 5,0) mg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PB-12 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14761","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d1","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(1,00 − 60,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 − 60,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (1,00 − 60,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576-08","norm_bases":["PN-82/C-04576-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,00 − 60,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576-08 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,00 − 60,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576-08","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576-08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,00 − 60,0) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576-08","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d2","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(4 − 60) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(4 − 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (4 − 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (4 − 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (4 − 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(4 − 60) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d3","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 − 50) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 − 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 − 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 − 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 − 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 − 50) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d4","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 − 3000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 − 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 − 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 − 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 − 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 − 3000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d5","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d6","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(30 − 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(30 − 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (30 − 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-19 wydanie 3 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14897","norm_bases":["PB-19 wydanie 3 z dnia 01.09.2020 r.","na podstawie testu Merck Nr 1.14897"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (30 − 250) mg/l\nMetoda spektrofotometryczna PB-19 wydanie 3 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14897 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (30 − 250) mg/l\nMetoda spektrofotometryczna PB-19 wydanie 3 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14897","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Chloride concentration Spectrophotometric method Range PB-19 wydanie 3 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14897","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(30 − 250) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 分光光度法 范围 PB-19 wydanie 3 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14897","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d7","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(20 − 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(20 − 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (20 − 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-40 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14548","norm_bases":["PB-40 wydanie 2 z dnia 01.09.2020 r.","na podstawie testu Merck Nr 1.14548"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (20 − 250) mg/l\nMetoda spektrofotometryczna PB-40 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14548 Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (20 − 250) mg/l\nMetoda spektrofotometryczna PB-40 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14548","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sulfate concentration Spectrophotometric method Range PB-40 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14548","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20 − 250) mg/l"}],"search_zh":"生活饮用水 硫酸盐浓度 分光光度法 范围 PB-40 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14548","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601d8","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Obecność obcego zapachu","methodology_en":"Presence of foreign odour","parameters":[{"name":"Liczba progowa zapachu (TON)"},{"name":"Zakres","range":"1"}],"parameters_en":[{"name":"Odour threshold number (TON)"},{"name":"Range","range":"1"}],"technique":"Metoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda jakościowa","Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Qualitative method; Simplified paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Obecność obcego zapachu\nZakres:\nLiczba progowa zapachu (TON)\nZakres 1\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Obecność obcego zapachu\nZakres:\nLiczba progowa zapachu (TON)\nZakres 1\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego zapachu\nZakres:\nLiczba progowa zapachu (TON)\nZakres 1\nMetoda jakosciowa; Metoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Presence of foreign odour Qualitative method; Simplified paired method, non-forced choice Odour threshold number (TON) Range PN-EN 1622:2006","parameters_zh":[{"name":"嗅阈值（TON）"},{"name":"范围","range":"1"}],"search_zh":"生活饮用水 异味的检出 定性法；简化法、成对法、非强制选择 嗅阈值（TON） 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"异味的检出","technique_zh":"定性法；简化法、成对法、非强制选择"},{"_id":"6a5dc9c4f1c10c8ce82601d9","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Obecność obcego smaku","methodology_en":"Presence of foreign taste","parameters":[{"name":"Liczba progowa smaku (TFN)"},{"name":"Zakres","range":"1"}],"parameters_en":[{"name":"Taste threshold number (TFN)"},{"name":"Range","range":"1"}],"technique":"Metoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda jakościowa","Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Qualitative method; Simplified paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Obecność obcego smaku\nZakres:\nLiczba progowa smaku (TFN)\nZakres 1\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Obecność obcego smaku\nZakres:\nLiczba progowa smaku (TFN)\nZakres 1\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego smaku\nZakres:\nLiczba progowa smaku (TFN)\nZakres 1\nMetoda jakosciowa; Metoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Presence of foreign taste Qualitative method; Simplified paired method, non-forced choice Taste threshold number (TFN) Range PN-EN 1622:2006","parameters_zh":[{"name":"味阈值（TFN）"},{"name":"范围","range":"1"}],"search_zh":"生活饮用水 异味（口感）的检出 定性法；简化法、成对法、非强制选择 味阈值（TFN） 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"异味（口感）的检出","technique_zh":"定性法；简化法、成对法、非强制选择"},{"_id":"6a5dc9c4f1c10c8ce82601da","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601db","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"22 °C 微生物总数"},{"_id":"6a5dc9c4f1c10c8ce82601dc","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 36 °C","methodology_en":"Total microorganism count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total microorganism count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a5dc9c4f1c10c8ce82601dd","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["water","microbiology"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601de","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["water","microbiology"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601df","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków","methodology_en":"Enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"肠球菌计数","search_zh":"生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601e0","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c4f1c10c8ce82601e1","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(4,0 − 40,0) °C"}],"parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(4,0 − 40,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 − 40,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 − 40,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 − 40,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(4,0 − 40,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce82601e2","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","test_object_en":"Rainwater, snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(4,0 − 40,0) °C"}],"parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(4,0 − 40,0) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 − 40,0) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 − 40,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (4,0 − 40,0) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(4,0 − 40,0) °C"}],"search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a5dc9c4f1c10c8ce82601e3","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","methodology_en":"Sampling for chemical and physical testing Temperature","parameters":[{"name":"Zakres","range":"(4,0 − 40,0) °C"}],"parameters_en":[{"name":"Range","range":"(4,0 − 40,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 − 40,0) °C","reference":"PN-ISO 5667-6:2016-12 p. 7.2, 7.4 | PN-77/C-04584","norm_bases":["PN-ISO 5667-6:2016-12 p. 7.2, 7.4","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (4,0 − 40,0) °C PN-ISO 5667-6:2016-12 p. 7.2, 7.4 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (4,0 − 40,0) °C PN-ISO 5667-6:2016-12 p. 7.2, 7.4 | PN-77/C-04584","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature Range PN-ISO 5667-6:2016-12 p. 7.2, 7.4 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(4,0 − 40,0) °C"}],"search_zh":"水 化学和物理检测采样 温度 范围 PN-ISO 5667-6:2016-12 p. 7.2, 7.4 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a5dc9c4f1c10c8ce82601e4","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki, Wody opadowe, wody roztopowe, Woda","test_object_en":"Wastewater, Rainwater, snowmelt water, Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody opadowe, wody roztopowe, Woda Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Wody opadowe, wody roztopowe, Woda Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Rainwater, snowmelt water, Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9c4f1c10c8ce82601e5","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki, Wody opadowe, wody roztopowe, Woda","test_object_en":"Wastewater, Rainwater, snowmelt water, Water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody opadowe, wody roztopowe, Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, Wody opadowe, wody roztopowe, Woda pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Rainwater, snowmelt water, Water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法"},{"_id":"6a5dc9c4f1c10c8ce82601e6","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 15) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 − 15) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 − 15) mg/l\nMetoda spektrofotometryczna","reference":"PB-13 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14537","norm_bases":["PB-13 wydanie 7 z dnia 01.09.2020 r.","na podstawie testu Merck Nr 1.14537"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 − 15) mg/l\nMetoda spektrofotometryczna PB-13 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14537 Scieki Stezenie azotu ogolnego\nZakres (1,0 − 15) mg/l\nMetoda spektrofotometryczna PB-13 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14537","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB-13 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14537","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 15) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB-13 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14537","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce82601e7","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,20 − 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 − 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,20 − 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-14 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14543","norm_bases":["PB-14 wydanie 7 z dnia 01.09.2020 r.","na podstawie testu Merck Nr 1.14543"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,20 − 5,0) mg/l\nMetoda spektrofotometryczna PB-14 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14543 Scieki Stezenie fosforu ogolnego\nZakres (0,20 − 5,0) mg/l\nMetoda spektrofotometryczna PB-14 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14543","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PB-14 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14543","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,20 − 5,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PB-14 wydanie 7 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14543","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce82601e8","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(0,10 – 8,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 8,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (0,10 – 8,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-43 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14549","norm_bases":["PB-43 wydanie 2 z dnia 01.09.2020 r.","na podstawie testu Merck Nr 1.14549"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie żelaza\nZakres (0,10 – 8,0) mg/l\nMetoda spektrofotometryczna PB-43 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14549 Scieki Stezenie zelaza\nZakres (0,10 – 8,0) mg/l\nMetoda spektrofotometryczna PB-43 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14549","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Iron concentration Spectrophotometric method Range PB-43 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14549","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 8,0) mg/l"}],"search_zh":"污水 铁浓度 分光光度法 范围 PB-43 wydanie 2 z dnia 01.09.2020 r. | na podstawie testu Merck Nr 1.14549","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c4f1c10c8ce82601e9","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 − 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 − 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 − 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie chlorków\nZakres (5,00 − 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda Stezenie chlorkow\nZakres (5,00 − 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 − 5000) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce82601ea","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","methodology_en":"Chemical oxygen demand − COD-Cr","parameters":[{"name":"Zakres","range":"(10 − 50000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(10 − 50000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10 − 50000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10 − 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, woda Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (10 − 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Chemical oxygen demand − COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(10 − 50000) mg/l O2"}],"search_zh":"废水、水 化学需氧量 － COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a5dc9c4f1c10c8ce82601eb","lab_id":"69ad52a3de79e566650fb506","country":"PL","accr_number":"AB 998","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","methodology_en":"Biochemical oxygen demand − BOD5","parameters":[{"name":"Zakres","range":"(1 − 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1 − 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 − 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 − 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 − 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Biochemical oxygen demand − BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1 − 6000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"}],"has_pdf":true}