{"lab":{"_id":"69ad52a3de79e566650fb500","accr_number":"AB 994","country":"PL","accr_body":"PCA","address":"ul. Kurta Aldera 44, 41-506 Chorzów","categories":["environment","materials"],"city":"Chorzów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":98,"name":"PROFTECH Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_994.pdf"],"scope_summary":"","search_text":"proftech sp. z o.o. ul. kurta aldera 44, 41-506 chorzów environment other metrology food materials","status":"active","updated_at":"2026-03-08T14:51:52.786Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:52.786Z","location":{"type":"Point","coordinates":[18.9549,50.2974]},"email_confidence":"high","email_mx":true,"email_source":"https://proftech.com.pl/kontakt/","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors - noise),"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne - gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) - general environment - waste gases"},{"codes":"M/58","pl":"Badania inne QAL2 i AST automatycznych systemów monitoringu (AMS)","en":"Other tests - QAL2 i AST of automated measuring systems (AMS),"},{"codes":"N/36/P","pl":"Badanie właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases,"},{"codes":"P/9","pl":"Pobieranie próbek powietrza atmosferycznego","en":"Sampling of air"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"25","date":"11.12.2025"},"parse_date":"2026-07-20T07:09:56.526Z","parse_source":"script-pdfplumber","map_coord":[50.267586,18.954424],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":55,"environment":38,"materials":5,"metrology":2},"category_scores":{"other":30.25,"environment":14.44,"materials":0.25,"metrology":0.04},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce8260128","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze atmosferyczne","test_object_en":"General environment - ambient air","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","methodology_en":"Sampling for determination of concentrations of organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego/żelu krzemionkowego","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego/żelu krzemionkowego"],"technique_en":"Aspiration method using activated carbon/silica gel","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego/żelu krzemionkowego","reference":"PB-05 wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-05 wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - powietrze atmosferyczne Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego/żelu krzemionkowego PB-05 wydanie 3 z dnia 01.02.2021 r. Srodowisko ogolne - powietrze atmosferyczne Pobieranie probek do oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego/zelu krzemionkowego PB-05 wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - ambient air Sampling for determination of concentrations of organic compounds Aspiration method using activated carbon/silica gel PB-05 wydanie 3 z dnia 01.02.2021 r.","methodology_zh":"有机化合物浓度测定采样","search_zh":"一般环境 － 大气空气 有机化合物浓度测定采样 PB-05 wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5dc9c4f1c10c8ce8260129","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze atmosferyczne","test_object_en":"General environment - ambient air","methodology":"Stężenie związków organicznych (z obliczeń)","methodology_en":"Concentration of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie związków organicznych (z obliczeń)","reference":"PB-05 wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-05 wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - powietrze atmosferyczne Stężenie związków organicznych (z obliczeń) PB-05 wydanie 3 z dnia 01.02.2021 r. Srodowisko ogolne - powietrze atmosferyczne Stezenie zwiazkow organicznych (z obliczen) PB-05 wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - ambient air Concentration of organic compounds (calculated) PB-05 wydanie 3 z dnia 01.02.2021 r.","search_zh":"一般环境 － 大气空气 PB-05 wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5dc9c4f1c10c8ce826012a","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze atmosferyczne","test_object_en":"General environment - ambient air","methodology":"Pobieranie próbek do oznaczania stężenia siarkowodoru","methodology_en":"Sampling for determination of hydrogen sulphide concentration","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"technique_en":"Aspiration method using absorbing solutions","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia siarkowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"PB-05 wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-05 wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - powietrze atmosferyczne Pobieranie próbek do oznaczania stężenia siarkowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających PB-05 wydanie 3 z dnia 01.02.2021 r. Srodowisko ogolne - powietrze atmosferyczne Pobieranie probek do oznaczania stezenia siarkowodoru\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych PB-05 wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - ambient air Sampling for determination of hydrogen sulphide concentration Aspiration method using absorbing solutions PB-05 wydanie 3 z dnia 01.02.2021 r.","search_zh":"一般环境 － 大气空气 用于测定硫化氢浓度的采样 采用吸收液的抽气法 PB-05 wydanie 3 z dnia 01.02.2021 r.","technique_zh":"采用吸收液的抽气法","test_object_zh":"一般环境 － 大气空气","methodology_zh":"用于测定硫化氢浓度的采样"},{"_id":"6a5dc9c4f1c10c8ce826012b","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze atmosferyczne","test_object_en":"General environment - ambient air","methodology":"Stężenie siarkowodoru (z obliczeń)","methodology_en":"Hydrogen sulphide concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarkowodoru (z obliczeń)","reference":"PB-05 wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-05 wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - powietrze atmosferyczne Stężenie siarkowodoru (z obliczeń) PB-05 wydanie 3 z dnia 01.02.2021 r. Srodowisko ogolne - powietrze atmosferyczne Stezenie siarkowodoru (z obliczen) PB-05 wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - ambient air Hydrogen sulphide concentration (calculated) PB-05 wydanie 3 z dnia 01.02.2021 r.","search_zh":"一般环境 － 大气空气 PB-05 wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5dc9c4f1c10c8ce826012c","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze atmosferyczne","test_object_en":"General environment - ambient air","methodology":"Pobieranie próbek do oznaczania stężeń związków nieorganicznych i organicznych","methodology_en":"Sampling for the determination of concentrations of inorganic and organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem worków Tedlarowych","techniques":["Metoda aspiracyjna z zastosowaniem worków Tedlarowych"],"technique_en":"Aspiration method using Tedlar bags","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków nieorganicznych i organicznych\nMetoda aspiracyjna z zastosowaniem worków Tedlarowych","reference":"PB-05 wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-05 wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - powietrze atmosferyczne Pobieranie próbek do oznaczania stężeń związków nieorganicznych i organicznych\nMetoda aspiracyjna z zastosowaniem worków Tedlarowych PB-05 wydanie 3 z dnia 01.02.2021 r. Srodowisko ogolne - powietrze atmosferyczne Pobieranie probek do oznaczania stezen zwiazkow nieorganicznych i organicznych\nMetoda aspiracyjna z zastosowaniem workow Tedlarowych PB-05 wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - ambient air Sampling for the determination of concentrations of inorganic and organic compounds Aspiration method using Tedlar bags PB-05 wydanie 3 z dnia 01.02.2021 r.","search_zh":"一般环境 － 大气空气 PB-05 wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5dc9c4f1c10c8ce826012d","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze atmosferyczne","test_object_en":"General environment - ambient air","methodology":"Stężenie związków organicznych i nieorganicznych (z obliczeń)","methodology_en":"Concentration of organic and inorganic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie związków organicznych i nieorganicznych (z obliczeń)","reference":"PB-05 wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-05 wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - powietrze atmosferyczne Stężenie związków organicznych i nieorganicznych (z obliczeń) PB-05 wydanie 3 z dnia 01.02.2021 r. Srodowisko ogolne - powietrze atmosferyczne Stezenie zwiazkow organicznych i nieorganicznych (z obliczen) PB-05 wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - ambient air Concentration of organic and inorganic compounds (calculated) PB-05 wydanie 3 z dnia 01.02.2021 r.","search_zh":"一般环境 － 大气空气 PB-05 wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5dc9c4f1c10c8ce826012e","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze atmosferyczne","test_object_en":"General environment - ambient air","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","methodology_en":"Sampling for determination of ammonia concentration","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"technique_en":"Aspiration method using absorbing solutions","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"PN-Z-04009-2:1999 | PB-05 wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PN-Z-04009-2:1999","PB-05 wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - powietrze atmosferyczne Pobieranie próbek do oznaczania stężenia amoniaku\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających PN-Z-04009-2:1999 | PB-05 wydanie 3 z dnia 01.02.2021 r. Srodowisko ogolne - powietrze atmosferyczne Pobieranie probek do oznaczania stezenia amoniaku\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych PN-Z-04009-2:1999 | PB-05 wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - ambient air Sampling for determination of ammonia concentration Aspiration method using absorbing solutions PN-Z-04009-2:1999 | PB-05 wydanie 3 z dnia 01.02.2021 r.","methodology_zh":"氨浓度测定采样","search_zh":"一般环境 － 大气空气 氨浓度测定采样 采用吸收液的抽气法 PN-Z-04009-2:1999 | PB-05 wydanie 3 z dnia 01.02.2021 r.","technique_zh":"采用吸收液的抽气法","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a5dc9c4f1c10c8ce826012f","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(20 - 135) dB"}],"parameters_en":[{"name":"Range","range":"(20 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (20 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (20 - 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (20 - 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(20 - 135) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9c4f1c10c8ce8260130","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9c4f1c10c8ce8260131","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa","methodology_en":"Gas velocity and volume flow rate for differential pressures > 5 Pa","parameters":[],"parameters_en":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"technique_en":"Differential pressure measurement method","computed":[],"computed_en":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych > 5 Pa\nMetoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas velocity and volume flow rate for differential pressures > 5 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","search_zh":"废气 压差 > 5 Pa 时的气体流速与体积流量 差压测量法 PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","test_object_zh":"废气","technique_zh":"差压测量法","methodology_zh":"压差 > 5 Pa 时的气体流速与体积流量"},{"_id":"6a5dc9c4f1c10c8ce8260132","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters":[],"parameters_en":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"technique_en":"Stagnation pressure method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a5dc9c4f1c10c8ce8260133","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce8260134","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 - 34) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 - 34) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 - 34) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 - 34) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 - 34) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 34) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260135","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce8260136","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce8260137","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,0005 - 0,05) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,0005 - 0,05) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,0005 - 0,05) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,0005 - 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,0005 - 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,05) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260138","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce8260139","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie SO2, NOx, CO, CO2, O2","methodology_en":"SO2, NOx, CO, CO2, O2 concentration","parameters":[{"name":"CO2","range":"(0,1 - 20) % obj."},{"name":"SO2","range":"(7,0 - 2860) mg/m3"},{"name":"CO","range":"(5,0 - 625) mg/m3"},{"name":"NOx","range":"(6,0 - 512) mg/m3"},{"name":"O2","range":"(1,5 - 21) % obj."}],"parameters_en":[{"name":"CO2","range":"(0,1 - 20) % obj."},{"name":"SO2","range":"(7,0 - 2860) mg/m3"},{"name":"CO","range":"(5,0 - 625) mg/m3"},{"name":"NOx","range":"(6,0 - 512) mg/m3"},{"name":"O2","range":"(1,5 - 21) % obj."}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencji; Metoda paramagnetyczna","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","Metoda chemiluminescencji","Metoda paramagnetyczna"],"technique_en":"Non-dispersive infrared spectrometry method (NDIR); Chemiluminescence method; Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie SO2, NOx, CO, CO2, O2\nZakres:\nCO2 (0,1 - 20) % obj.\nSO2 (7,0 - 2860) mg/m3\nCO (5,0 - 625) mg/m3\nNOx (6,0 - 512) mg/m3\nO2 (1,5 - 21) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencji; Metoda paramagnetyczna","reference":"ISO 10396:2007","norm_bases":["ISO 10396:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie SO2, NOx, CO, CO2, O2\nZakres:\nCO2 (0,1 - 20) % obj.\nSO2 (7,0 - 2860) mg/m3\nCO (5,0 - 625) mg/m3\nNOx (6,0 - 512) mg/m3\nO2 (1,5 - 21) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencji; Metoda paramagnetyczna ISO 10396:2007 Gazy odlotowe Stezenie SO2, NOx, CO, CO2, O2\nZakres:\nCO2 (0,1 - 20) % obj.\nSO2 (7,0 - 2860) mg/m3\nCO (5,0 - 625) mg/m3\nNOx (6,0 - 512) mg/m3\nO2 (1,5 - 21) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencji; Metoda paramagnetyczna ISO 10396:2007","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2, NOx, CO, CO2, O2 concentration Non-dispersive infrared spectrometry method (NDIR); Chemiluminescence method; Paramagnetic method CO2 SO2 CO NOx O2 ISO 10396:2007","search_zh":"废气 CO2 SO2 CO NOx O2 ISO 10396:2007","test_object_zh":"废气","parameters_zh":[{"name":"CO2","range":"(0,1 - 20) % obj."},{"name":"SO2","range":"(7,0 - 2860) mg/m3"},{"name":"CO","range":"(5,0 - 625) mg/m3"},{"name":"NOx","range":"(6,0 - 512) mg/m3"},{"name":"O2","range":"(1,5 - 21) % obj."}]},{"_id":"6a5dc9c4f1c10c8ce826013a","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2, NOx, CO, CO2 (z obliczeń)","methodology_en":"Emission of SO2, NOx, CO, CO2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2, NOx, CO, CO2 (z obliczeń)","reference":"ISO 10396:2007","norm_bases":["ISO 10396:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2, NOx, CO, CO2 (z obliczeń) ISO 10396:2007 Gazy odlotowe Emisja SO2, NOx, CO, CO2 (z obliczen) ISO 10396:2007","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of SO2, NOx, CO, CO2 (calculated) ISO 10396:2007","search_zh":"废气 ISO 10396:2007","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826013b","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia SO2","methodology_en":"Sampling for determination of SO2 concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-04","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of SO2 concentration PN-EN 14791:2017-04","search_zh":"废气 用于测定 SO2 浓度的采样 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a5dc9c4f1c10c8ce826013c","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie SO2","methodology_en":"SO2 concentration","parameters":[{"name":"Zakres","range":"(2,86 - 2000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,86 - 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie SO2\nZakres (2,86 - 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (2,86 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie SO2\nZakres (2,86 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 concentration Thoron method Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(2,86 - 2000) mg/m3"}],"search_zh":"废气 SO2 浓度 钍射气法 范围 PN-EN 14791:2017-04","test_object_zh":"废气","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a5dc9c4f1c10c8ce826013d","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2 (z obliczeń)","methodology_en":"SO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 emission (calculated) PN-EN 14791:2017-04","search_zh":"废气 SO2 排放量（计算值） PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce826013e","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie O2","methodology_en":"O2 concentration","parameters":[{"name":"Zakres","range":"(1,5 - 21) %"}],"parameters_en":[{"name":"Range","range":"(1,5 - 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie O2\nZakres (1,5 - 21) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie O2\nZakres (1,5 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Gazy odlotowe Stezenie O2\nZakres (1,5 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases O2 concentration Paramagnetic method Range PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(1,5 - 21) %"}],"search_zh":"废气 O2 浓度 顺磁法 范围 PN-EN 14789:2017-04","test_object_zh":"废气","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a5dc9c4f1c10c8ce826013f","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie NOX","methodology_en":"NOX concentration","parameters":[{"name":"Zakres","range":"(6,0 - 512) mg/m3"}],"parameters_en":[{"name":"Range","range":"(6,0 - 512) mg/m3"}],"technique":"Metoda chemiluminescencji","techniques":["Metoda chemiluminescencji"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie NOX\nZakres (6,0 - 512) mg/m3\nMetoda chemiluminescencji","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie NOX\nZakres (6,0 - 512) mg/m3\nMetoda chemiluminescencji PN-EN 14792:2017-04 Gazy odlotowe Stezenie NOX\nZakres (6,0 - 512) mg/m3\nMetoda chemiluminescencji PN-EN 14792:2017-04","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases NOX concentration Chemiluminescence method Range PN-EN 14792:2017-04","parameters_zh":[{"name":"范围","range":"(6,0 - 512) mg/m3"}],"search_zh":"废气 化学发光法 范围 PN-EN 14792:2017-04","test_object_zh":"废气","technique_zh":"化学发光法"},{"_id":"6a5dc9c4f1c10c8ce8260140","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NOX (z obliczeń)","methodology_en":"Emission of NOX (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NOX (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NOX (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NOX (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of NOX (calculated) PN-EN 14792:2017-04","search_zh":"废气 PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260141","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie CO2","methodology_en":"CO2 concentration","parameters":[{"name":"Zakres","range":"(0,1 - 20) % obj."}],"parameters_en":[{"name":"Range","range":"(0,1 - 20) % obj."}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Gazy odlotowe Stezenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CO2 concentration Non-dispersive infrared spectrometry (NDIR) Range ISO 12039:2019","parameters_zh":[{"name":"范围","range":"(0,1 - 20) % obj."}],"search_zh":"废气 CO2 浓度 非分散红外光谱法（NDIR） 范围 ISO 12039:2019","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO2 浓度"},{"_id":"6a5dc9c4f1c10c8ce8260142","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie CO","methodology_en":"CO concentration","parameters":[{"name":"Zakres","range":"(5,0 - 625) mg/m3"}],"parameters_en":[{"name":"Range","range":"(5,0 - 625) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO\nZakres (5,0 - 625) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie CO\nZakres (5,0 - 625) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Gazy odlotowe Stezenie CO\nZakres (5,0 - 625) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CO concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04","parameters_zh":[{"name":"范围","range":"(5,0 - 625) mg/m3"}],"search_zh":"废气 CO 浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO 浓度"},{"_id":"6a5dc9c4f1c10c8ce8260143","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO (z obliczeń)","methodology_en":"CO emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN 15058:2017-04 Gazy odlotowe Emisja CO (z obliczen) PN-EN 15058:2017-04","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CO emission (calculated) PN-EN 15058:2017-04","search_zh":"废气 CO 排放量（计算值） PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce8260144","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(0,4 - 1000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,4 - 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)"],"technique_en":"Continuous flame ionization detection method (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,4 - 1000) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,4 - 1000) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (0,4 - 1000) mg/m3\nMetoda ciaglej detekcji plomieniowojonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05","parameters_zh":[{"name":"范围","range":"(0,4 - 1000) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a5dc9c4f1c10c8ce8260145","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce8260146","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia masowego PCDD/PDF oraz PCB typu dioksyn","methodology_en":"Sampling for determination of the mass concentration of PCDD/PDF and dioxin-like PCB","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia masowego PCDD/PDF oraz PCB typu dioksyn","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia masowego PCDD/PDF oraz PCB typu dioksyn PN-EN 1948-1:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia masowego PCDD/PDF oraz PCB typu dioksyn PN-EN 1948-1:2006","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the mass concentration of PCDD/PDF and dioxin-like PCB PN-EN 1948-1:2006","search_zh":"废气 PN-EN 1948-1:2006","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260147","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja PCDD/PDF oraz PCB typu dioksyn (z obliczeń)","methodology_en":"Emission of PCDD/PDF and dioxin-like PCBs (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja PCDD/PDF oraz PCB typu dioksyn (z obliczeń)","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja PCDD/PDF oraz PCB typu dioksyn (z obliczeń) PN-EN 1948-1:2006 Gazy odlotowe Emisja PCDD/PDF oraz PCB typu dioksyn (z obliczen) PN-EN 1948-1:2006","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of PCDD/PDF and dioxin-like PCBs (calculated) PN-EN 1948-1:2006","search_zh":"废气 PN-EN 1948-1:2006","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260148","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia HCl","methodology_en":"Sampling for the determination of HCl concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia HCl","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia HCl PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia HCl PN-EN 1911:2011","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of HCl concentration PN-EN 1911:2011","search_zh":"废气 用于测定 HCl 浓度的采样 PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"用于测定 HCl 浓度的采样"},{"_id":"6a5dc9c4f1c10c8ce8260149","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie HCl","methodology_en":"HCl concentration","parameters":[{"name":"Zakres","range":"(1,00 - 5 000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,00 - 5 000) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie HCl\nZakres (1,00 - 5 000) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie HCl\nZakres (1,00 - 5 000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie HCl\nZakres (1,00 - 5 000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HCl concentration Spectrophotometric method Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(1,00 - 5 000) mg/m3"}],"search_zh":"废气 HCl 浓度 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"HCl 浓度"},{"_id":"6a5dc9c4f1c10c8ce826014a","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HCl (z obliczeń)","methodology_en":"HCl emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HCl emission (calculated) PN-EN 1911:2011","search_zh":"废气 HCl 排放（由计算得出） PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce826014b","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia HF","methodology_en":"Sampling for determination of HF concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia HF","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia HF ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia HF ISO 15713:2006","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of HF concentration ISO 15713:2006","search_zh":"废气 用于测定 HF 浓度的采样 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"用于测定 HF 浓度的采样"},{"_id":"6a5dc9c4f1c10c8ce826014c","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie HF","methodology_en":"HF concentration","parameters":[{"name":"Zakres","range":"(0,100 - 200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,100 - 200) mg/m3"}],"technique":"Metoda z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda z zastosowaniem elektrody jonoselektywnej"],"technique_en":"Method using an ion-selective electrode","computed":[],"computed_en":[],"activity":"Stężenie HF\nZakres (0,100 - 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie HF\nZakres (0,100 - 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 Gazy odlotowe Stezenie HF\nZakres (0,100 - 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HF concentration Method using an ion-selective electrode Range ISO 15713:2006","parameters_zh":[{"name":"范围","range":"(0,100 - 200) mg/m3"}],"search_zh":"废气 HF 浓度 离子选择电极法 范围 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"HF 浓度","technique_zh":"离子选择电极法"},{"_id":"6a5dc9c4f1c10c8ce826014d","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HF (z obliczeń)","methodology_en":"HF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HF emission (calculated) ISO 15713:2006","search_zh":"废气 HF 排放量（计算值） ISO 15713:2006","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce826014e","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń metali (As; Cd; Cr; Co; Cu; Mn; Ni; Pb; Sb; Tl; V)","methodology_en":"Sampling for determination of metal concentrations (As; Cd; Cr; Co; Cu; Mn; Ni; Pb; Sb; Tl; V)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń metali (As; Cd; Cr; Co; Cu; Mn; Ni; Pb; Sb; Tl; V)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń metali (As; Cd; Cr; Co; Cu; Mn; Ni; Pb; Sb; Tl; V) PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczania stezen metali (As; Cd; Cr; Co; Cu; Mn; Ni; Pb; Sb; Tl; V) PN-EN 14385:2025-05","categories":["materials"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations (As; Cd; Cr; Co; Cu; Mn; Ni; Pb; Sb; Tl; V) PN-EN 14385:2025-05","search_zh":"废气 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826014f","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali (z obliczeń)","methodology_en":"Metal emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja metali (z obliczen) PN-EN 14385:2025-05","categories":["materials","environment"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Metal emission (calculated) PN-EN 14385:2025-05","search_zh":"废气 金属排放（由计算得出） PN-EN 14385:2025-05","test_object_zh":"废气","methodology_zh":"金属排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce8260150","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia Hg","methodology_en":"Sampling for the determination of Hg concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia Hg","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia Hg PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia Hg PN-EN 13211+AC:2006","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of Hg concentration PN-EN 13211+AC:2006","search_zh":"废气 PN-EN 13211+AC:2006","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260151","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja Hg (z obliczeń)","methodology_en":"Hg emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja Hg (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja Hg (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja Hg (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hg emission (calculated) PN-EN 13211+AC:2006","search_zh":"废气 Hg 排放（由计算得出） PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"Hg 排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce8260152","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego"],"technique_en":"Aspiration method using activated carbon","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego PN-EN 13649:2005","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Aspiration method using activated carbon PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物浓度测定采样 活性炭抽气采样法 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样","technique_zh":"活性炭抽气采样法"},{"_id":"6a5dc9c4f1c10c8ce8260153","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce8260154","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(29 - 250) g/m3"}],"parameters_en":[{"name":"Range","range":"(29 - 250) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"technique_en":"Condensation-adsorption method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (29 - 250) g/m3\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres (29 - 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres (29 - 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method Range PN-EN 14790:2017-04","parameters_zh":[{"name":"范围","range":"(29 - 250) g/m3"}],"search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a5dc9c4f1c10c8ce8260155","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie pyłu, SO2, CO, O2, NOx, CO2, całkowitego gazowego węgla organicznego, HCl, HF, H2O, Hg","methodology_en":"AMS calibration (QAL2) for dust, SO2, CO, O2, NOx, CO2, total gaseous organic carbon, HCl, HF, H2O, Hg","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie pyłu, SO2, CO, O2, NOx, CO2, całkowitego gazowego węgla organicznego, HCl, HF, H2O, Hg","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie pyłu, SO2, CO, O2, NOx, CO2, całkowitego gazowego węgla organicznego, HCl, HF, H2O, Hg PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie pylu, SO2, CO, O2, NOx, CO2, calkowitego gazowego wegla organicznego, HCl, HF, H2O, Hg PN-EN 14181:2015-02","categories":["metrology"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for dust, SO2, CO, O2, NOx, CO2, total gaseous organic carbon, HCl, HF, H2O, Hg PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce8260156","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczna kontrola sprawności (AST) w zakresie: pyłu, SO2, CO, O2, NOx, CO2, całkowitego węgla organicznego, HCl, HF, H2O, Hg","methodology_en":"Annual surveillance test (AST) for: dust, SO2, CO, O2, NOx, CO2, total organic carbon, HCl, HF, H2O, Hg","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczna kontrola sprawności (AST) w zakresie: pyłu, SO2, CO, O2, NOx, CO2, całkowitego węgla organicznego, HCl, HF, H2O, Hg","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczna kontrola sprawności (AST) w zakresie: pyłu, SO2, CO, O2, NOx, CO2, całkowitego węgla organicznego, HCl, HF, H2O, Hg PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczna kontrola sprawnosci (AST) w zakresie: pylu, SO2, CO, O2, NOx, CO2, calkowitego wegla organicznego, HCl, HF, H2O, Hg PN-EN 14181:2015-02","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, SO2, CO, O2, NOx, CO2, total organic carbon, HCl, HF, H2O, Hg PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce8260157","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 - 34) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 - 34) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 - 34) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,001 - 34) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,001 - 34) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 34) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce8260158","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,0005 - 0,05) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,0005 - 0,05) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,0005 - 0,05) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,0005 - 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,0005 - 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,05) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce8260159","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie SO2","methodology_en":"SO2 concentration","parameters":[{"name":"Zakres","range":"(2,86 - 2000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,86 - 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie SO2\nZakres (2,86 - 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie SO2\nZakres (2,86 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie SO2\nZakres (2,86 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) SO2 concentration Thoron method Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(2,86 - 2000) mg/m3"}],"search_zh":"自动测量系统（AMS） SO2 浓度 钍射气法 范围 PN-EN 14791:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a5dc9c4f1c10c8ce826015a","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie O2","methodology_en":"O2 concentration","parameters":[{"name":"Zakres","range":"(1,5 - 21) %"}],"parameters_en":[{"name":"Range","range":"(1,5 - 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie O2\nZakres (1,5 - 21) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie O2\nZakres (1,5 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie O2\nZakres (1,5 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) O2 concentration Paramagnetic method Range PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(1,5 - 21) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法 范围 PN-EN 14789:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a5dc9c4f1c10c8ce826015b","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NOx","methodology_en":"NOx concentration","parameters":[{"name":"Zakres","range":"(6,0 - 512) mg/m3"}],"parameters_en":[{"name":"Range","range":"(6,0 - 512) mg/m3"}],"technique":"Metoda chemiluminescencji","techniques":["Metoda chemiluminescencji"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie NOx\nZakres (6,0 - 512) mg/m3\nMetoda chemiluminescencji","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NOx\nZakres (6,0 - 512) mg/m3\nMetoda chemiluminescencji PN-EN 14792:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie NOx\nZakres (6,0 - 512) mg/m3\nMetoda chemiluminescencji PN-EN 14792:2017-04","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NOx concentration Chemiluminescence method Range PN-EN 14792:2017-04","parameters_zh":[{"name":"范围","range":"(6,0 - 512) mg/m3"}],"search_zh":"自动测量系统（AMS） NOx 浓度 化学发光法 范围 PN-EN 14792:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"NOx 浓度","technique_zh":"化学发光法"},{"_id":"6a5dc9c4f1c10c8ce826015c","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO","methodology_en":"CO concentration","parameters":[{"name":"Zakres","range":"(5,0 - 625) mg/m3"}],"parameters_en":[{"name":"Range","range":"(5,0 - 625) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO\nZakres (5,0 - 625) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO\nZakres (5,0 - 625) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO\nZakres (5,0 - 625) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04","parameters_zh":[{"name":"范围","range":"(5,0 - 625) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO 浓度"},{"_id":"6a5dc9c4f1c10c8ce826015d","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO2","methodology_en":"CO2 concentration","parameters":[{"name":"Zakres","range":"(0,1 - 20) % obj."}],"parameters_en":[{"name":"Range","range":"(0,1 - 20) % obj."}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 10396:2007","norm_bases":["ISO 10396:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 10396:2007 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 10396:2007","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO2 concentration Non-dispersive infrared spectrometry (NDIR) Range ISO 10396:2007","parameters_zh":[{"name":"范围","range":"(0,1 - 20) % obj."}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外光谱法（NDIR） 范围 ISO 10396:2007","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO2 浓度"},{"_id":"6a5dc9c4f1c10c8ce826015e","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO2","methodology_en":"CO2 concentration","parameters":[{"name":"Zakres","range":"(0,1 - 20) % obj."}],"parameters_en":[{"name":"Range","range":"(0,1 - 20) % obj."}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO2\nZakres (0,1 - 20) % obj.\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO2 concentration Non-dispersive infrared spectrometry (NDIR) Range ISO 12039:2019","parameters_zh":[{"name":"范围","range":"(0,1 - 20) % obj."}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外光谱法（NDIR） 范围 ISO 12039:2019","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO2 浓度"},{"_id":"6a5dc9c4f1c10c8ce826015f","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(0,4 - 1000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,4 - 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)"],"technique_en":"Continuous flame ionization detection method (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,4 - 1000) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,4 - 1000) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID) PN-EN 12619:2013-05 Automatyczne Systemy, Monitoringu (AMS) Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (0,4 - 1000) mg/m3\nMetoda ciaglej detekcji plomieniowojonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05","parameters_zh":[{"name":"范围","range":"(0,4 - 1000) mg/m3"}],"search_zh":"自动测量系统（AMS） 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05","test_object_zh":"自动测量系统（AMS）","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a5dc9c4f1c10c8ce8260160","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie HCl","methodology_en":"HCl concentration","parameters":[{"name":"Zakres","range":"(1,00 - 5 000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,00 - 5 000) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie HCl\nZakres (1,00 - 5 000) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie HCl\nZakres (1,00 - 5 000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Automatyczne Systemy, Monitoringu (AMS) Stezenie HCl\nZakres (1,00 - 5 000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) HCl concentration Spectrophotometric method Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(1,00 - 5 000) mg/m3"}],"search_zh":"自动测量系统（AMS） HCl 浓度 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"HCl 浓度"},{"_id":"6a5dc9c4f1c10c8ce8260161","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie HF","methodology_en":"HF concentration","parameters":[{"name":"Zakres","range":"(0,100 - 200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,100 - 200) mg/m3"}],"technique":"Metoda z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda z zastosowaniem elektrody jonoselektywnej"],"technique_en":"Method using an ion-selective electrode","computed":[],"computed_en":[],"activity":"Stężenie HF\nZakres (0,100 - 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie HF\nZakres (0,100 - 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 Automatyczne Systemy, Monitoringu (AMS) Stezenie HF\nZakres (0,100 - 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006","categories":["other"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) HF concentration Method using an ion-selective electrode Range ISO 15713:2006","parameters_zh":[{"name":"范围","range":"(0,100 - 200) mg/m3"}],"search_zh":"自动测量系统（AMS） HF 浓度 离子选择电极法 范围 ISO 15713:2006","test_object_zh":"自动测量系统（AMS）","methodology_zh":"HF 浓度","technique_zh":"离子选择电极法"},{"_id":"6a5dc9c4f1c10c8ce8260162","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(29 - 250) g/m3"}],"parameters_en":[{"name":"Range","range":"(29 - 250) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"technique_en":"Condensation-adsorption method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (29 - 250) g/m3\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pary wodnej (H2O)\nZakres (29 - 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie pary wodnej (H2O)\nZakres (29 - 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Water vapour concentration (H2O) Condensation-adsorption method Range PN-EN 14790:2017-04","parameters_zh":[{"name":"范围","range":"(29 - 250) g/m3"}],"search_zh":"自动测量系统（AMS） 水蒸气浓度（H2O） 冷凝-吸附法 范围 PN-EN 14790:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a5dc9c4f1c10c8ce8260163","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie NH3, N2O","methodology_en":"AMS calibration (QAL2) for NH3, N2O","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie NH3, N2O","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie NH3, N2O PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie NH3, N2O PN-EN 14181:2015-02","categories":["metrology"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for NH3, N2O PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce8260164","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczna kontrola sprawności (AST) w zakresie NH3, N2O","methodology_en":"Annual surveillance test (AST) for NH3, N2O","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczna kontrola sprawności (AST) w zakresie NH3, N2O","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczna kontrola sprawności (AST) w zakresie NH3, N2O PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczna kontrola sprawnosci (AST) w zakresie NH3, N2O PN-EN 14181:2015-02","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for NH3, N2O PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce8260165","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NH3","methodology_en":"NH3 concentration","parameters":[{"name":"Zakres","range":"(0,5 - 100) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 - 100) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie NH3\nZakres (0,5 - 100) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NH3\nZakres (0,5 - 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Automatyczne Systemy, Monitoringu (AMS) Stezenie NH3\nZakres (0,5 - 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NH3 concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,5 - 100) mg/m3"}],"search_zh":"自动测量系统（AMS） NH3 浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"NH3 浓度"},{"_id":"6a5dc9c4f1c10c8ce8260166","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie N2O","methodology_en":"N2O concentration","parameters":[{"name":"Zakres","range":"(2,0 - 400) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,0 - 400) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie N2O\nZakres (2,0 - 400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie N2O\nZakres (2,0 - 400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Automatyczne Systemy, Monitoringu (AMS) Stezenie N2O\nZakres (2,0 - 400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) N2O concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010","parameters_zh":[{"name":"范围","range":"(2,0 - 400) mg/m3"}],"search_zh":"自动测量系统（AMS） N2O 浓度 非分散红外光谱法（NDIR） 范围 PN-EN ISO 21258:2010","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a5dc9c4f1c10c8ce8260167","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia Hg","methodology_en":"Sampling for the determination of Hg concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia Hg","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia Hg PN-EN 13211+AC:2006 Automatyczne Systemy, Monitoringu (AMS) Pobieranie probek do oznaczania stezenia Hg PN-EN 13211+AC:2006","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Sampling for the determination of Hg concentration PN-EN 13211+AC:2006","search_zh":"自动测量系统（AMS） PN-EN 13211+AC:2006","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce8260168","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania frakcji pyłu","methodology_en":"Sampling for determination of the dust fraction","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania frakcji pyłu","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PB-04 wydanie 5 z dnia 01.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania frakcji pyłu PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r. Gazy odlotowe Pobieranie probek do oznaczania frakcji pylu PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the dust fraction PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","search_zh":"废气 用于测定粉尘分级的采样 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","test_object_zh":"废气","methodology_zh":"用于测定粉尘分级的采样"},{"_id":"6a5dc9c4f1c10c8ce8260169","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja frakcji pyłu (z obliczeń)","methodology_en":"Emission of the dust fraction (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PB-04 wydanie 5 z dnia 01.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r. Gazy odlotowe Emisja frakcji pylu (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","categories":["environment"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of the dust fraction (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","search_zh":"废气 粉尘分级排放（由计算得出） PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-04 wydanie 5 z dnia 01.09.2019 r.","test_object_zh":"废气","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce826016a","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","methodology_en":"Sampling for determination of concentrations of organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z wykorzystaniem rurek z żelem krzemionkowym","techniques":["Metoda aspiracyjna z wykorzystaniem rurek z żelem krzemionkowym"],"technique_en":"Aspiration method using silica gel tubes","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z wykorzystaniem rurek z żelem krzemionkowym","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z wykorzystaniem rurek z żelem krzemionkowym PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z wykorzystaniem rurek z zelem krzemionkowym PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of concentrations of organic compounds Aspiration method using silica gel tubes PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 有机化合物浓度测定采样 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气","methodology_zh":"有机化合物浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce826016b","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["environment"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic compounds (calculated) PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 有机化合物排放量（计算值） PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce826016c","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń siarkowodoru i amoniaku","methodology_en":"Sampling for determination of the concentrations of hydrogen sulfide and ammonia","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"technique_en":"Aspiration method using absorbing solutions","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń siarkowodoru i amoniaku\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń siarkowodoru i amoniaku\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Pobieranie probek do oznaczania stezen siarkowodoru i amoniaku\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentrations of hydrogen sulfide and ammonia Aspiration method using absorbing solutions PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 采用吸收液的抽气法 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气","technique_zh":"采用吸收液的抽气法"},{"_id":"6a5dc9c4f1c10c8ce826016d","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja siarkowodoru i amoniaku (z obliczeń)","methodology_en":"Emission of hydrogen sulphide and ammonia (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja siarkowodoru i amoniaku (z obliczeń)","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja siarkowodoru i amoniaku (z obliczeń) PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Emisja siarkowodoru i amoniaku (z obliczen) PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["environment"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of hydrogen sulphide and ammonia (calculated) PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826016e","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek","methodology_en":"Sampling","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem worków Tedlar","techniques":["Metoda aspiracyjna z zastosowaniem worków Tedlar"],"technique_en":"Aspiration method using Tedlar bags","computed":[],"computed_en":[],"activity":"Pobieranie próbek\nMetoda aspiracyjna z zastosowaniem worków Tedlar","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek\nMetoda aspiracyjna z zastosowaniem worków Tedlar PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Pobieranie probek\nMetoda aspiracyjna z zastosowaniem workow Tedlar PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling Aspiration method using Tedlar bags PB-02 wydanie 8 z dnia 01.09.2025 r.","methodology_zh":"样品采集","search_zh":"废气 样品采集 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826016f","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja gazów odlotowych (z obliczeń)","methodology_en":"Emission of waste gases (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja gazów odlotowych (z obliczeń)","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja gazów odlotowych (z obliczeń) PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Emisja gazow odlotowych (z obliczen) PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of waste gases (calculated) PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260170","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczenia stężeń olei mineralnych","methodology_en":"Sampling for determination of the concentrations of mineral oils","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem filtrów","techniques":["Metoda aspiracyjna z zastosowaniem filtrów"],"technique_en":"Aspiration method using filters","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczenia stężeń olei mineralnych\nMetoda aspiracyjna z zastosowaniem filtrów","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężeń olei mineralnych\nMetoda aspiracyjna z zastosowaniem filtrów PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Pobieranie probek do oznaczenia stezen olei mineralnych\nMetoda aspiracyjna z zastosowaniem filtrow PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentrations of mineral oils Aspiration method using filters PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 滤膜抽气采样法 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气","technique_zh":"滤膜抽气采样法"},{"_id":"6a5dc9c4f1c10c8ce8260171","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja olei mineralnych (z obliczeń)","methodology_en":"Emission of mineral oils (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja olei mineralnych (z obliczeń)","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja olei mineralnych (z obliczeń) PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Emisja olei mineralnych (z obliczen) PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["environment"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of mineral oils (calculated) PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260172","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń kwasu siarkowego VI, fluorków i tritlenku siarki.","methodology_en":"Sampling for determination of the concentrations of sulfuric VI acid, fluorides and sulfur trioxide.","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z wykorzystaniem filtrów membranowych","techniques":["Metoda aspiracyjna z wykorzystaniem filtrów membranowych"],"technique_en":"Aspiration method using membrane filters","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń kwasu siarkowego VI, fluorków i tritlenku siarki.\nMetoda aspiracyjna z wykorzystaniem filtrów membranowych","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń kwasu siarkowego VI, fluorków i tritlenku siarki.\nMetoda aspiracyjna z wykorzystaniem filtrów membranowych PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Pobieranie probek do oznaczania stezen kwasu siarkowego VI, fluorkow i tritlenku siarki.\nMetoda aspiracyjna z wykorzystaniem filtrow membranowych PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentrations of sulfuric VI acid, fluorides and sulfur trioxide. Aspiration method using membrane filters PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260173","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja kwasu siarkowego VI, fluorków i tritlenku siarki (z obliczeń)","methodology_en":"Emission of sulphuric acid VI, fluorides and sulphur trioxide (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja kwasu siarkowego VI, fluorków i tritlenku siarki (z obliczeń)","reference":"PB-02 wydanie 8 z dnia 01.09.2025 r.","norm_bases":["PB-02 wydanie 8 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja kwasu siarkowego VI, fluorków i tritlenku siarki (z obliczeń) PB-02 wydanie 8 z dnia 01.09.2025 r. Gazy odlotowe Emisja kwasu siarkowego VI, fluorkow i tritlenku siarki (z obliczen) PB-02 wydanie 8 z dnia 01.09.2025 r.","categories":["environment"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of sulphuric acid VI, fluorides and sulphur trioxide (calculated) PB-02 wydanie 8 z dnia 01.09.2025 r.","search_zh":"废气 PB-02 wydanie 8 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260174","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń amoniaku","methodology_en":"Sampling for determination of ammonia concentrations","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"technique_en":"Aspiration method using absorbing solutions","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń amoniaku\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń amoniaku\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezen amoniaku\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych PN-EN ISO 21877:2020-03","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of ammonia concentrations Aspiration method using absorbing solutions PN-EN ISO 21877:2020-03","search_zh":"废气 采用吸收液的抽气法 PN-EN ISO 21877:2020-03","test_object_zh":"废气","technique_zh":"采用吸收液的抽气法"},{"_id":"6a5dc9c4f1c10c8ce8260175","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie NH3","methodology_en":"NH3 concentration","parameters":[{"name":"Zakres","range":"(0,5 - 100) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 - 100) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie NH3\nZakres (0,5 - 100) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie NH3\nZakres (0,5 - 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe Stezenie NH3\nZakres (0,5 - 100) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases NH3 concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,5 - 100) mg/m3"}],"search_zh":"废气 NH3 浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"NH3 浓度"},{"_id":"6a5dc9c4f1c10c8ce8260176","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja amoniaku (z obliczeń)","methodology_en":"Ammonia emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03","search_zh":"废气 氨排放量（计算值） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce8260177","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń metali (Al; As; Ba; B; Cd; Cr; Co; Cu; Fe; K; Li; Mn; Mo; Na; Ni; Pb; Sb; Sn; Tl; V; Zn; Se) w pyle","methodology_en":"Sampling for determination of metal concentrations (Al; As; Ba; B; Cd; Cr; Co; Cu; Fe; K; Li; Mn; Mo; Na; Ni; Pb; Sb; Sn; Tl; V; Zn; Se) in dust","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń metali (Al; As; Ba; B; Cd; Cr; Co; Cu; Fe; K; Li; Mn; Mo; Na; Ni; Pb; Sb; Sn; Tl; V; Zn; Se) w pyle","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PB-03 wydanie 5 z dnia 01.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń metali (Al; As; Ba; B; Cd; Cr; Co; Cu; Fe; K; Li; Mn; Mo; Na; Ni; Pb; Sb; Sn; Tl; V; Zn; Se) w pyle PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r. Gazy odlotowe Pobieranie probek do oznaczania stezen metali (Al; As; Ba; B; Cd; Cr; Co; Cu; Fe; K; Li; Mn; Mo; Na; Ni; Pb; Sb; Sn; Tl; V; Zn; Se) w pyle PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","categories":["materials"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations (Al; As; Ba; B; Cd; Cr; Co; Cu; Fe; K; Li; Mn; Mo; Na; Ni; Pb; Sb; Sn; Tl; V; Zn; Se) in dust PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","search_zh":"废气 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260178","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali (z obliczeń)","methodology_en":"Metal emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PB-03 wydanie 5 z dnia 01.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r. Gazy odlotowe Emisja metali (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","categories":["materials","environment"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Metal emission (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","search_zh":"废气 金属排放（由计算得出） PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PB-03 wydanie 5 z dnia 01.09.2019 r.","test_object_zh":"废气","methodology_zh":"金属排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce8260179","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania masowego stężenia wielopierścieniowych węglowodorów aromatycznych WWA","methodology_en":"Sampling for determination of the mass concentration of polycyclic aromatic hydrocarbons PAH","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania masowego stężenia wielopierścieniowych węglowodorów aromatycznych WWA","reference":"ISO-11338-1:2003 – Metoda B","norm_bases":["ISO-11338-1:2003 – Metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania masowego stężenia wielopierścieniowych węglowodorów aromatycznych WWA ISO-11338-1:2003 – Metoda B Gazy odlotowe Pobieranie probek do oznaczania masowego stezenia wielopierscieniowych weglowodorow aromatycznych WWA ISO-11338-1:2003 – Metoda B","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the mass concentration of polycyclic aromatic hydrocarbons PAH ISO-11338-1:2003 – Metoda B","search_zh":"废气 ISO-11338-1:2003 – Metoda B","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826017a","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń)","methodology_en":"Emission of polycyclic aromatic hydrocarbons PAH (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń)","reference":"ISO-11338-1:2003 – Metoda B","norm_bases":["ISO-11338-1:2003 – Metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja wielopierścieniowych węglowodorów aromatycznych WWA (z obliczeń) ISO-11338-1:2003 – Metoda B Gazy odlotowe Emisja wielopierscieniowych weglowodorow aromatycznych WWA (z obliczen) ISO-11338-1:2003 – Metoda B","categories":["environment"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of polycyclic aromatic hydrocarbons PAH (calculated) ISO-11338-1:2003 – Metoda B","search_zh":"废气 ISO-11338-1:2003 – Metoda B","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826017b","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania masowego PCB","methodology_en":"Sampling for mass determination of PCB","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania masowego PCB","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania masowego PCB PN-EN 1948-4+A1:2014-03 Gazy odlotowe Pobieranie probek do oznaczania masowego PCB PN-EN 1948-4+A1:2014-03","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for mass determination of PCB PN-EN 1948-4+A1:2014-03","search_zh":"废气 PN-EN 1948-4+A1:2014-03","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826017c","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja PCB (z obliczeń)","methodology_en":"PCB emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja PCB (z obliczeń)","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja PCB (z obliczeń) PN-EN 1948-4+A1:2014-03 Gazy odlotowe Emisja PCB (z obliczen) PN-EN 1948-4+A1:2014-03","categories":["environment"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases PCB emission (calculated) PN-EN 1948-4+A1:2014-03","search_zh":"废气 PCB 排放（由计算得出） PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","methodology_zh":"PCB 排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce826017d","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania SO3","methodology_en":"Sampling for determination of SO3","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania SO3","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania SO3 VDI 2462-2:2011 Gazy odlotowe Pobieranie probek do oznaczania SO3 VDI 2462-2:2011","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of SO3 VDI 2462-2:2011","search_zh":"废气 VDI 2462-2:2011","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce826017e","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie SO3","methodology_en":"SO3 concentration","parameters":[{"name":"Zakres","range":"(5,0 - 50) mg/m3"}],"parameters_en":[{"name":"Range","range":"(5,0 - 50) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie SO3\nZakres (5,0 - 50) mg/m3\nMetoda toronowa","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie SO3\nZakres (5,0 - 50) mg/m3\nMetoda toronowa VDI 2462-2:2011 Gazy odlotowe Stezenie SO3\nZakres (5,0 - 50) mg/m3\nMetoda toronowa VDI 2462-2:2011","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO3 concentration Thoron method Range VDI 2462-2:2011","parameters_zh":[{"name":"范围","range":"(5,0 - 50) mg/m3"}],"search_zh":"废气 钍射气法 范围 VDI 2462-2:2011","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a5dc9c4f1c10c8ce826017f","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO3 (z obliczeń)","methodology_en":"SO3 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO3 (z obliczeń)","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO3 (z obliczeń) VDI 2462-2:2011 Gazy odlotowe Emisja SO3 (z obliczen) VDI 2462-2:2011","categories":["environment"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO3 emission (calculated) VDI 2462-2:2011","search_zh":"废气 SO3 排放（由计算得出） VDI 2462-2:2011","test_object_zh":"废气","methodology_zh":"SO3 排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce8260180","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie N2O","methodology_en":"N2O concentration","parameters":[{"name":"Zakres","range":"(2,0 - 400) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,0 - 400) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie N2O\nZakres (2,0 - 400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie N2O\nZakres (2,0 - 400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Gazy odlotowe Stezenie N2O\nZakres (2,0 - 400) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases N2O concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010","parameters_zh":[{"name":"范围","range":"(2,0 - 400) mg/m3"}],"search_zh":"废气 N2O 浓度 非分散红外光谱法（NDIR） 范围 PN-EN ISO 21258:2010","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a5dc9c4f1c10c8ce8260181","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja N2O (z obliczeń)","methodology_en":"N2O emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja N2O (z obliczeń)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja N2O (z obliczeń) PN-EN ISO 21258:2010 Gazy odlotowe Emisja N2O (z obliczen) PN-EN ISO 21258:2010","categories":["environment"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases N2O emission (calculated) PN-EN ISO 21258:2010","search_zh":"废气 N2O 排放（由计算得出） PN-EN ISO 21258:2010","test_object_zh":"废气","methodology_zh":"N2O 排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce8260182","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metali (Al, Sn, Zn, Se, Fe)","methodology_en":"Sampling for determination of metal concentrations (Al, Sn, Zn, Se, Fe)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metali (Al, Sn, Zn, Se, Fe)","reference":"PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","norm_bases":["PN-EN 14385:2025-05","PB-08 wydanie 2 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali (Al, Sn, Zn, Se, Fe) PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia metali (Al, Sn, Zn, Se, Fe) PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","categories":["materials"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations (Al, Sn, Zn, Se, Fe) PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","search_zh":"废气 PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260183","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja Al, Sn, Zn, Se, Fe (z obliczeń)","methodology_en":"Emission of Al, Sn, Zn, Se, Fe (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja Al, Sn, Zn, Se, Fe (z obliczeń)","reference":"PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","norm_bases":["PN-EN 14385:2025-05","PB-08 wydanie 2 z dnia 01.09.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja Al, Sn, Zn, Se, Fe (z obliczeń) PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r. Gazy odlotowe Emisja Al, Sn, Zn, Se, Fe (z obliczen) PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","categories":["environment"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of Al, Sn, Zn, Se, Fe (calculated) PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","search_zh":"废气 PN-EN 14385:2025-05 | PB-08 wydanie 2 z dnia 01.09.2025 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260184","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia związków nieorganicznych: chlor","methodology_en":"Sampling for determination of the concentration of inorganic compounds: chlorine","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia związków nieorganicznych: chlor","reference":"PB-10 wydanie 1 z dnia 01.07.2021 r.","norm_bases":["PB-10 wydanie 1 z dnia 01.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia związków nieorganicznych: chlor PB-10 wydanie 1 z dnia 01.07.2021 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia zwiazkow nieorganicznych: chlor PB-10 wydanie 1 z dnia 01.07.2021 r.","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of inorganic compounds: chlorine PB-10 wydanie 1 z dnia 01.07.2021 r.","search_zh":"废气 PB-10 wydanie 1 z dnia 01.07.2021 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260185","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków nieorganicznych: chlor (z obliczeń)","methodology_en":"Emission of inorganic compounds: chlorine (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków nieorganicznych: chlor (z obliczeń)","reference":"PB-10 wydanie 1 z dnia 01.07.2021 r.","norm_bases":["PB-10 wydanie 1 z dnia 01.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków nieorganicznych: chlor (z obliczeń) PB-10 wydanie 1 z dnia 01.07.2021 r. Gazy odlotowe Emisja zwiazkow nieorganicznych: chlor (z obliczen) PB-10 wydanie 1 z dnia 01.07.2021 r.","categories":["environment"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of inorganic compounds: chlorine (calculated) PB-10 wydanie 1 z dnia 01.07.2021 r.","search_zh":"废气 PB-10 wydanie 1 z dnia 01.07.2021 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260186","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania masowego polibromowanych dibenzo-p-dioksyn/furanów (PBDD/F)","methodology_en":"Sampling for mass determination of polybrominated dibenzo-p-dioxins/furans (PBDD/F)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania masowego polibromowanych dibenzo-p-dioksyn/furanów (PBDD/F)","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03","PB-11 wydanie 1 z dnia 01.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania masowego polibromowanych dibenzo-p-dioksyn/furanów (PBDD/F) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r. Gazy odlotowe Pobieranie probek do oznaczania masowego polibromowanych dibenzo-p-dioksyn/furanow (PBDD/F) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","categories":["other"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for mass determination of polybrominated dibenzo-p-dioxins/furans (PBDD/F) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","search_zh":"废气 PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260187","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja PBDD/F (z obliczeń)","methodology_en":"Emission of PBDD/F (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja PBDD/F (z obliczeń)","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03","PB-11 wydanie 1 z dnia 01.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja PBDD/F (z obliczeń) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r. Gazy odlotowe Emisja PBDD/F (z obliczen) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","categories":["environment"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of PBDD/F (calculated) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","search_zh":"废气 PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260188","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania masowego bromowanych związków opóźniających zapłon (BFR)","methodology_en":"Sampling for mass determination of brominated flame retardants (BFR)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania masowego bromowanych związków opóźniających zapłon (BFR)","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03","PB-11 wydanie 1 z dnia 01.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania masowego bromowanych związków opóźniających zapłon (BFR) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r. Gazy odlotowe Pobieranie probek do oznaczania masowego bromowanych zwiazkow opozniajacych zaplon (BFR) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for mass determination of brominated flame retardants (BFR) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","search_zh":"废气 PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce8260189","lab_id":"69ad52a3de79e566650fb500","country":"PL","accr_number":"AB 994","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja BFR (z obliczeń)","methodology_en":"Emission of BFR (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja BFR (z obliczeń)","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03","PB-11 wydanie 1 z dnia 01.09.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja BFR (z obliczeń) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r. Gazy odlotowe Emisja BFR (z obliczen) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","categories":["environment"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of BFR (calculated) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","search_zh":"废气 PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 | PB-11 wydanie 1 z dnia 01.09.2024 r.","test_object_zh":"废气"}],"has_pdf":true}