{"lab":{"_id":"69ad52a3de79e566650fb4f0","accr_number":"AB 981","country":"PL","accr_body":"PCA","address":"Laboratorium, ul. Elektryczna 20 A, 82-300 Elbląg","categories":["petro","water"],"city":"Elbląg","imported_at":"2026-03-08T10:42:43.265Z","methods_count":37,"name":"ENERGA Kogeneracja Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_981.pdf"],"scope_summary":"","search_text":"energa kogeneracja sp. z o.o. laboratorium, ul. elektryczna 20 a, 82-300 elbląg materials petro pharma other environment water","status":"active","updated_at":"2026-03-08T14:51:52.237Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:52.237Z","location":{"type":"Point","coordinates":[19.4048,54.1522]},"email_confidence":"high","email_mx":true,"email_source":"http://energa-kogeneracja.pl/kontakt","fields_of_testing":[{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych, odpadów","en":"Chemical tests of solid fuels, waste"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"}],"issue":{"no":"22","date":"29.11.2024"},"parse_date":"2026-07-20T07:09:56.341Z","parse_source":"script-pdfplumber","map_coord":[54.182033,19.386245],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":28,"water":8,"materials":1,"environment":1},"category_scores":{"petro":20.63,"water":1.68,"materials":0.03,"environment":0.03},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce8260072","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca)","methodology_en":"First-stage moisture content (transient moisture)","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca)\nZakres (1,0 – 30,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A","norm_bases":["PN-ISO 589:2006 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca)\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoc przemijajaca)\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal First-stage moisture content (transient moisture) Gravimetric method Range PN-ISO 589:2006 Metoda A","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a5dc9c4f1c10c8ce8260073","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoć węgla powietrznosuchego)","methodology_en":"Second-stage moisture content (moisture of air-dry coal)","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoć węgla powietrznosuchego)\nZakres (1,0 – 10,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1; A2","norm_bases":["PN-ISO 589:2006 Metoda A1; A2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoć węgla powietrznosuchego)\nZakres (1,0 – 10,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1; A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoc wegla powietrznosuchego)\nZakres (1,0 – 10,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1; A2","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Second-stage moisture content (moisture of air-dry coal) Gravimetric method Range PN-ISO 589:2006 Metoda A1; A2","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-ISO 589:2006 Metoda A1; A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce8260074","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(1,00 – 10,00) %"}],"parameters_en":[{"name":"Range","range":"(1,00 – 10,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (1,00 – 10,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci analitycznej\nZakres (1,00 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci analitycznej\nZakres (1,00 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Analytical moisture content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(1,00 – 10,00) %"}],"search_zh":"固体燃料：烟煤 分析水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤","methodology_zh":"分析水分含量"},{"_id":"6a5dc9c4f1c10c8ce8260075","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 Metoda A","norm_bases":["PN-ISO 589:2006 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 Metoda A Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 Metoda A","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 Metoda A","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 Metoda A","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce8260076","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 10,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (1,0 – 10,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci analitycznej\nZakres (1,0 – 10,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci analitycznej\nZakres (1,0 – 10,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Analytical moisture content Gravimetric method Range PN-ISO 11722:2009","parameters_zh":[{"name":"范围","range":"(1,0 – 10,0) %"}],"search_zh":"固体燃料：烟煤 分析水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"分析水分含量"},{"_id":"6a5dc9c4f1c10c8ce8260077","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce8260078","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(1,00 – 40,00) %"}],"parameters_en":[{"name":"Range","range":"(1,00 – 40,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (1,00 – 40,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (1,00 – 40,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (1,00 – 40,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,00 – 40,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce8260079","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartości części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(10,00 – 45,00) %"}],"parameters_en":[{"name":"Range","range":"(10,00 – 45,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartości części lotnych\nZakres (10,00 – 45,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartości części lotnych\nZakres (10,00 – 45,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosci czesci lotnych\nZakres (10,00 – 45,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","parameters_zh":[{"name":"范围","range":"(10,00 – 45,00) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce826007a","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartości części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(10,00 – 45,00) %"}],"parameters_en":[{"name":"Range","range":"(10,00 – 45,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartości części lotnych\nZakres (10,00 – 45,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartości części lotnych\nZakres (10,00 – 45,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosci czesci lotnych\nZakres (10,00 – 45,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Volatile matter content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(10,00 – 45,00) %"}],"search_zh":"固体燃料：烟煤 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce826007b","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,20 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,20 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,20 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,20 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,20 – 2,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce826007c","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(7000 – 35 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(7000 – 35 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (7000 – 35 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (7000 – 35 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (7000 – 35 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-ISO 1928:2020-05","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(7000 – 35 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce826007d","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,04 – 0,65) %"}],"parameters_en":[{"name":"Range","range":"(0,04 – 0,65) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,04 – 0,65) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000 pkt 7.2.1","norm_bases":["PN-ISO 587:2000 pkt 7.2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość chloru\nZakres (0,04 – 0,65) %\nMetoda miareczkowa PN-ISO 587:2000 pkt 7.2.1 Paliwa stale: wegiel kamienny Zawartosc chloru\nZakres (0,04 – 0,65) %\nMetoda miareczkowa PN-ISO 587:2000 pkt 7.2.1","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Chlorine content Titrimetric method Range PN-ISO 587:2000 pkt 7.2.1","parameters_zh":[{"name":"范围","range":"(0,04 – 0,65) %"}],"search_zh":"固体燃料：烟煤 氯含量 滴定法 范围 PN-ISO 587:2000 pkt 7.2.1","technique_zh":"滴定法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氯含量"},{"_id":"6a5dc9c4f1c10c8ce826007e","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(35,0 – 90,0) %"}],"parameters_en":[{"name":"Range","range":"(35,0 – 90,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (35,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (35,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (35,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(35,0 – 90,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c4f1c10c8ce826007f","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(3,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a5dc9c4f1c10c8ce8260080","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Odpady: kod 100101, 100102, 100115, 100117","test_object_en":"Waste: code 100101, 100102, 100115, 100117","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,2 – 15,0) %"}],"parameters_en":[{"name":"Range","range":"(0,2 – 15,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (0,2 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 100101, 100102, 100115, 100117 Zawartość węgla całkowitego\nZakres (0,2 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady: kod 100101, 100102, 100115, 100117 Zawartosc wegla calkowitego\nZakres (0,2 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 100101, 100102, 100115, 100117 Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,2 – 15,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a5dc9c4f1c10c8ce8260081","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(4,0 – 60,0)%"}],"parameters_en":[{"name":"Range","range":"(4,0 – 60,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (4,0 – 60,0)%\nMetoda wagowa","reference":"PN-EN ISO 18134-1:2023-02 | PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-1:2023-02","PN-EN ISO 18134-2:2024-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (4,0 – 60,0)%\nMetoda wagowa PN-EN ISO 18134-1:2023-02 | PN-EN ISO 18134-2:2024-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (4,0 – 60,0)%\nMetoda wagowa PN-EN ISO 18134-1:2023-02 | PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Total moisture content Gravimetric method Range PN-EN ISO 18134-1:2023-02 | PN-EN ISO 18134-2:2024-10","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(4,0 – 60,0)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全水分含量 重量法 范围 PN-EN ISO 18134-1:2023-02 | PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce8260082","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(4,0 – 15,0)%"}],"parameters_en":[{"name":"Range","range":"(4,0 – 15,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (4,0 – 15,0)%\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci analitycznej\nZakres (4,0 – 15,0)%\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci analitycznej\nZakres (4,0 – 15,0)%\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Analytical moisture content Gravimetric method Range PN-EN ISO 18134-3:2023-12","parameters_zh":[{"name":"范围","range":"(4,0 – 15,0)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"分析水分含量"},{"_id":"6a5dc9c4f1c10c8ce8260083","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(4,0 – 15,0)%"}],"parameters_en":[{"name":"Range","range":"(4,0 – 15,0)%"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (4,0 – 15,0)%\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wilgoci analitycznej\nZakres (4,0 – 15,0)%\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wilgoci analitycznej\nZakres (4,0 – 15,0)%\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Analytical moisture content Thermogravimetric method (TGA) Range PN-EN ISO 18134-3:2023-12","parameters_zh":[{"name":"范围","range":"(4,0 – 15,0)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 分析水分含量 热重法（TGA） 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"分析水分含量"},{"_id":"6a5dc9c4f1c10c8ce8260084","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,2 – 15,0)%"}],"parameters_en":[{"name":"Range","range":"(0,2 – 15,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,2 – 15,0)%\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05 | PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 18122:2023-05","PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu\nZakres (0,2 – 15,0)%\nMetoda wagowa PN-EN ISO 18122:2023-05 | PN-EN ISO 21656:2021-08 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu\nZakres (0,2 – 15,0)%\nMetoda wagowa PN-EN ISO 18122:2023-05 | PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Ash content Gravimetric method Range PN-EN ISO 18122:2023-05 | PN-EN ISO 21656:2021-08","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 15,0)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量 重量法 范围 PN-EN ISO 18122:2023-05 | PN-EN ISO 21656:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce8260085","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,2 – 15,0)%"}],"parameters_en":[{"name":"Range","range":"(0,2 – 15,0)%"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,2 – 15,0)%\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość popiołu\nZakres (0,2 – 15,0)%\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc popiolu\nZakres (0,2 – 15,0)%\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Ash content Thermogravimetric method (TGA) Range PN-EN ISO 18122:2023-05","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,2 – 15,0)%"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 灰分含量 热重法（TGA） 范围 PN-EN ISO 18122:2023-05","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce8260086","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce8260087","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 1,00) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,02 – 1,00) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Total sulfur content Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 16994:2016-10","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 全硫含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 16994:2016-10","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce8260088","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,02 – 0,65) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 0,65) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,02 – 0,65) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość chloru\nZakres (0,02 – 0,65) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc chloru\nZakres (0,02 – 0,65) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Chlorine content Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 16994:2016-10","parameters_zh":[{"name":"范围","range":"(0,02 – 0,65) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氯含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 16994:2016-10","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氯含量"},{"_id":"6a5dc9c4f1c10c8ce8260089","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(15 000 – 27 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(15 000 – 27 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (15 000 – 27 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania\nZakres:\nZakres (15 000 – 27 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania\nZakres:\nZakres (15 000 – 27 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 18125:2017-07","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(15 000 – 27 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce826008a","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(38,0 – 60,0) %"}],"parameters_en":[{"name":"Range","range":"(38,0 – 60,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (38,0 – 60,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość węgla całkowitego\nZakres (38,0 – 60,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wegla calkowitego\nZakres (38,0 – 60,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(38,0 – 60,0) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce826008b","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(4,00 – 7,00) %"}],"parameters_en":[{"name":"Range","range":"(4,00 – 7,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (4,00 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość wodoru\nZakres (4,00 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc wodoru\nZakres (4,00 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","parameters_zh":[{"name":"范围","range":"(4,00 – 7,00) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","methodology_zh":"氢含量"},{"_id":"6a5dc9c4f1c10c8ce826008c","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość frakcji biodegradowalnej – udział masowy biomasy","methodology_en":"Biodegradable fraction content – mass fraction of biomass","parameters":[{"name":"Zakres","range":"(70,0 – 100) %"}],"parameters_en":[{"name":"Range","range":"(70,0 – 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość frakcji biodegradowalnej – udział masowy biomasy\nZakres (70,0 – 100) %\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07 pkt B7","norm_bases":["PN-EN ISO 21644:2021-07 pkt B7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość frakcji biodegradowalnej – udział masowy biomasy\nZakres (70,0 – 100) %\nMetoda wagowa PN-EN ISO 21644:2021-07 pkt B7 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc frakcji biodegradowalnej – udzial masowy biomasy\nZakres (70,0 – 100) %\nMetoda wagowa PN-EN ISO 21644:2021-07 pkt B7","categories":["petro"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Biodegradable fraction content – mass fraction of biomass Gravimetric method Range PN-EN ISO 21644:2021-07 pkt B7","parameters_zh":[{"name":"范围","range":"(70,0 – 100) %"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 重量法 范围 PN-EN ISO 21644:2021-07 pkt B7","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce826008d","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość pierwiastków","methodology_en":"Element content","parameters":[{"name":"kadm","range":"(0,070 – 1,5) mg/kg"},{"name":"chrom","range":"(0,20 – 70) mg/kg"},{"name":"miedź","range":"(0,80 – 300) mg/kg"},{"name":"nikiel","range":"(0,23 – 45) mg/kg"},{"name":"ołów","range":"(0,70 – 60) mg/kg"},{"name":"cynk","range":"(8,0 – 850) mg/kg"}],"parameters_en":[{"name":"cadmium","range":"(0,070 – 1,5) mg/kg"},{"name":"chromium","range":"(0,20 – 70) mg/kg"},{"name":"copper","range":"(0,80 – 300) mg/kg"},{"name":"nickel","range":"(0,23 – 45) mg/kg"},{"name":"lead","range":"(0,70 – 60) mg/kg"},{"name":"zinc","range":"(8,0 – 850) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków\nZakres:\nkadm (0,070 – 1,5) mg/kg\nchrom (0,20 – 70) mg/kg\nmiedź (0,80 – 300) mg/kg\nnikiel (0,23 – 45) mg/kg\nołów (0,70 – 60) mg/kg\ncynk (8,0 – 850) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 16968:2015-07","norm_bases":["PN-EN ISO 16968:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość pierwiastków\nZakres:\nkadm (0,070 – 1,5) mg/kg\nchrom (0,20 – 70) mg/kg\nmiedź (0,80 – 300) mg/kg\nnikiel (0,23 – 45) mg/kg\nołów (0,70 – 60) mg/kg\ncynk (8,0 – 850) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 16968:2015-07 Paliwa stale: biomasa stala – biopaliwo stale Zawartosc pierwiastkow\nZakres:\nkadm (0,070 – 1,5) mg/kg\nchrom (0,20 – 70) mg/kg\nmiedz (0,80 – 300) mg/kg\nnikiel (0,23 – 45) mg/kg\nolow (0,70 – 60) mg/kg\ncynk (8,0 – 850) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 16968:2015-07","categories":["petro","materials"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) cadmium chromium copper nickel lead zinc PN-EN ISO 16968:2015-07","methodology_zh":"元素含量","parameters_zh":[{"name":"镉","range":"(0,070 – 1,5) mg/kg"},{"name":"铬","range":"(0,20 – 70) mg/kg"},{"name":"铜","range":"(0,80 – 300) mg/kg"},{"name":"镍","range":"(0,23 – 45) mg/kg"},{"name":"铅","range":"(0,70 – 60) mg/kg"},{"name":"锌","range":"(8,0 – 850) mg/kg"}],"search_zh":"固体燃料：固体生物质 – 固体生物燃料 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 镉 铬 铜 镍 铅 锌 PN-EN ISO 16968:2015-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"},{"_id":"6a5dc9c4f1c10c8ce826008e","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Zawartość pierwiastków","methodology_en":"Element content","parameters":[{"name":"potas","range":"(0,10 – 30) g/kg"},{"name":"sód","range":"(0,080 – 3,6) g/kg"}],"parameters_en":[{"name":"potassium","range":"(0,10 – 30) g/kg"},{"name":"sodium","range":"(0,080 – 3,6) g/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków\nZakres:\npotas (0,10 – 30) g/kg\nsód (0,080 – 3,6) g/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 16967:2015-06 Metoda A","norm_bases":["PN-EN ISO 16967:2015-06 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Zawartość pierwiastków\nZakres:\npotas (0,10 – 30) g/kg\nsód (0,080 – 3,6) g/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 16967:2015-06 Metoda A Paliwa stale: biomasa stala – biopaliwo stale Zawartosc pierwiastkow\nZakres:\npotas (0,10 – 30) g/kg\nsod (0,080 – 3,6) g/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 16967:2015-06 Metoda A","categories":["petro"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: solid biomass – solid biofuel Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) potassium sodium PN-EN ISO 16967:2015-06 Metoda A","methodology_zh":"元素含量","search_zh":"固体燃料：固体生物质 – 固体生物燃料 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 钾 钠 PN-EN ISO 16967:2015-06 Metoda A","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料","parameters_zh":[{"name":"钾","range":"(0,10 – 30) g/kg"},{"name":"钠","range":"(0,080 – 3,6) g/kg"}]},{"_id":"6a5dc9c4f1c10c8ce826008f","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek ścieków do badań chemicznych i fizycznych","methodology_en":"Sampling of wastewater for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,0 – 50,0) 0C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,0 – 50,0) 0C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek ścieków do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 50,0) 0C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek ścieków do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 50,0) 0C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek sciekow do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,0 – 50,0) 0C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling of wastewater for chemical and physical testing Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,0 – 50,0) 0C"}],"search_zh":"污水 用于化学与物理检验的废水采样 手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工法","methodology_zh":"用于化学与物理检验的废水采样"},{"_id":"6a5dc9c4f1c10c8ce8260090","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych","methodology_en":"Water sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki wody"},{"name":"Zakres","range":"(0,0 – 50,0) 0C"}],"parameters_en":[{"name":"Temperature of the collected water sample"},{"name":"Range","range":"(0,0 – 50,0) 0C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (0,0 – 50,0) 0C\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek wody do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (0,0 – 50,0) 0C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7 | PN-77/C-04584 Woda Pobieranie probek wody do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki wody\nZakres (0,0 – 50,0) 0C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7 | PN-77/C-04584","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Water sampling for chemical and physical testing Manual method Temperature of the collected water sample Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7 | PN-77/C-04584","parameters_zh":[{"name":"所采水样的温度"},{"name":"范围","range":"(0,0 – 50,0) 0C"}],"search_zh":"水 手工法 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.2, 7.3, 7.5, 7.6, 8.2, 9.2, 9.3, 9.4, 10.6, 10.7 | PN-77/C-04584","test_object_zh":"水","technique_zh":"手工法"},{"_id":"6a5dc9c4f1c10c8ce8260091","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda Stezenie siarczanow\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9c4f1c10c8ce8260092","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"6,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"6,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 6,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda pH\nZakres 6,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda pH\nZakres 6,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"6,0 – 10,0"}],"search_zh":"废水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260093","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 50) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 50) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (2,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (2,0 – 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 50) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a5dc9c4f1c10c8ce8260094","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT)","methodology_en":"Chemical oxygen demand (COD)","parameters":[{"name":"Zakres","range":"(30 – 250) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(30 – 250) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (30 – 250) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (30 – 250) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki, woda Chemiczne zapotrzebowanie tlenu (ChZT)\nZakres (30 – 250) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Chemical oxygen demand (COD) Titrimetric method Range PN-ISO 6060:2006","parameters_zh":[{"name":"范围","range":"(30 – 250) mg/l O2"}],"search_zh":"废水、水 化学需氧量（COD） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"废水、水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c4f1c10c8ce8260095","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","methodology_en":"Biochemical oxygen demand (BOD5)","parameters":[{"name":"Zakres","range":"(1 – 200) mg/l O2"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1 – 200) mg/l O2"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres:\nZakres (1 – 200) mg/l O2\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12 | PN-EN 1899-2:2002","norm_bases":["PN-EN ISO 5815-1:2019-12","PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres:\nZakres (1 – 200) mg/l O2\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 | PN-EN 1899-2:2002 Scieki, woda Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres:\nZakres (1 – 200) mg/l O2\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 | PN-EN 1899-2:2002","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Biochemical oxygen demand (BOD5) Electrochemical method Range Range PN-EN ISO 5815-1:2019-12 | PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(1 – 200) mg/l O2"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 电化学法 范围 范围 PN-EN ISO 5815-1:2019-12 | PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c4f1c10c8ce8260096","lab_id":"69ad52a3de79e566650fb4f0","country":"PL","accr_number":"AB 981","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 - 6000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 - 6000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 - 6000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie chlorków\nZakres (5 - 6000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda Stezenie chlorkow\nZakres (5 - 6000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 6000) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水"}],"has_pdf":true}