{"lab":{"_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","address":"LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Powstania Styczniowego 95E/2, 20-706 Lublin","categories":["environment"],"city":"Lublin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":86,"name":"CE2 TECH CONSULTING M. DZIEWA I WSPÓLNICY Sp. j.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_974.pdf"],"scope_summary":"","search_text":"ce2 tech consulting m. dziewa i wspólnicy sp. j. laboratorium badań środowiskowych, ul. powstania styczniowego 95e/2, 20-706 lublin environment metrology other pharma materials","status":"active","updated_at":"2026-03-08T14:51:51.811Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:51.810Z","location":{"type":"Point","coordinates":[22.5684,51.2465]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20974,plik.html","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/34, G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe, środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – waste gases, general environment (physical factors – noise)"},{"codes":"M/39, M/58","pl":"Badania inne - urządzenia ochrony powietrza, automatyczne systemy monitoringu (AMS)","en":"Other tests - air protection equipment, automatic monitoring systems (AMS)"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"P/36","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"24","date":"21.11.2025"},"parse_date":"2026-07-20T07:09:56.076Z","parse_source":"script-pdfplumber","map_coord":[51.244684,22.496173],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":56,"environment":26,"materials":4,"metrology":2},"category_scores":{"other":35.64,"environment":7.68,"materials":0.18,"metrology":0.05},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce825ff5e","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce825ff5f","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff60","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff61","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters":[{"name":"Prędkość"},{"name":"Zakres","range":"(1 – 6) m/s"}],"parameters_en":[{"name":"Velocity"},{"name":"Range","range":"(1 – 6) m/s"}],"technique":"Metoda spiętrzenia; Metoda anemometryczna","techniques":["Metoda spiętrzenia","Metoda anemometryczna"],"technique_en":"Stagnation pressure method; Anemometric method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość\nZakres (1 – 6) m/s\nMetoda spiętrzenia; Metoda anemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość\nZakres (1 – 6) m/s\nMetoda spiętrzenia; Metoda anemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nZakres:\nPredkosc\nZakres (1 – 6) m/s\nMetoda spietrzenia; Metoda anemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method; Anemometric method Velocity Range PN-Z-04030-7:1994","parameters_zh":[{"name":"速度"},{"name":"范围","range":"(1 – 6) m/s"}],"search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法；风速仪法 速度 范围 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"皮托管法；风速仪法"},{"_id":"6a5dc9c4f1c10c8ce825ff62","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters":[{"name":"NO","range":"(2,7-1340) mg/m3"},{"name":"NOx","range":"(4,1 - 2050) mg/m3"}],"parameters_en":[{"name":"NO","range":"(2,7-1340) mg/m3"},{"name":"NOx","range":"(4,1 - 2050) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2,7-1340) mg/m3\nNOx (4,1 - 2050) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2,7-1340) mg/m3\nNOx (4,1 - 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (2,7-1340) mg/m3\nNOx (4,1 - 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method NO NOx PN-EN 14792:2017-04","search_zh":"废气 一氧化氮、氮氧化物浓度 化学发光法 NO NOx PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(2,7-1340) mg/m3"},{"name":"NOx","range":"(4,1 - 2050) mg/m3"}],"technique_zh":"化学发光法","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff63","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","methodology_en":"NO, NOx emission (NO and NO2 calculated as NO2) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated) PN-EN 14792:2017-04","search_zh":"废气 NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出） PN-EN 14792:2017-04","test_object_zh":"废气","methodology_zh":"NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ff64","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie ditlenku siarki, tlenku węgla, ditlenku węgla","methodology_en":"Concentration of sulphur dioxide, carbon monoxide, carbon dioxide","parameters":[{"name":"SO2","range":"(5,7 - 3000) mg/m3"},{"name":"CO","range":"(2,5 - 6250) mg/m3"},{"name":"CO2","range":"(0,5 - 25) %"},{"name":"Stężenie tlenków azotu"},{"name":"Zakres","range":"(4,1 - 2050) mg/m3"},{"name":"Stężenie tlenu"},{"name":"Zakres","range":"(0,5 - 23) %"}],"parameters_en":[{"name":"SO2","range":"(5,7 - 3000) mg/m3"},{"name":"CO","range":"(2,5 - 6250) mg/m3"},{"name":"CO2","range":"(0,5 - 25) %"},{"name":"Nitrogen oxides concentration"},{"name":"Range","range":"(4,1 - 2050) mg/m3"},{"name":"Oxygen concentration"},{"name":"Range","range":"(0,5 - 23) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda elektrochemiczna","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","Metoda chemiluminescencyjna","Metoda elektrochemiczna"],"technique_en":"Non-dispersive infrared spectrometry method (NDIR); Chemiluminescence method; Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie ditlenku siarki, tlenku węgla, ditlenku węgla\nZakres:\nSO2 (5,7 - 3000) mg/m3\nCO (2,5 - 6250) mg/m3\nCO2 (0,5 - 25) %\nStężenie tlenków azotu\nZakres (4,1 - 2050) mg/m3\nStężenie tlenu\nZakres (0,5 - 23) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie ditlenku siarki, tlenku węgla, ditlenku węgla\nZakres:\nSO2 (5,7 - 3000) mg/m3\nCO (2,5 - 6250) mg/m3\nCO2 (0,5 - 25) %\nStężenie tlenków azotu\nZakres (4,1 - 2050) mg/m3\nStężenie tlenu\nZakres (0,5 - 23) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie ditlenku siarki, tlenku wegla, ditlenku wegla\nZakres:\nSO2 (5,7 - 3000) mg/m3\nCO (2,5 - 6250) mg/m3\nCO2 (0,5 - 25) %\nStezenie tlenkow azotu\nZakres (4,1 - 2050) mg/m3\nStezenie tlenu\nZakres (0,5 - 23) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda chemiluminescencyjna; Metoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of sulphur dioxide, carbon monoxide, carbon dioxide Non-dispersive infrared spectrometry method (NDIR); Chemiluminescence method; Electrochemical method SO2 CO CO2 Nitrogen oxides concentration Range Oxygen concentration Range PN-ISO 10396:2001","parameters_zh":[{"name":"SO2","range":"(5,7 - 3000) mg/m3"},{"name":"CO","range":"(2,5 - 6250) mg/m3"},{"name":"CO2","range":"(0,5 - 25) %"},{"name":"氮氧化物浓度"},{"name":"范围","range":"(4,1 - 2050) mg/m3"},{"name":"氧浓度"},{"name":"范围","range":"(0,5 - 23) %"}],"search_zh":"废气 SO2 CO CO2 氮氧化物浓度 范围 氧浓度 范围 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff65","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2, CO, CO2 (z obliczeń)","methodology_en":"SO2, CO, CO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2, CO, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2, CO, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2, CO, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2, CO, CO2 emission (calculated) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff66","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,5 - 6250) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,5 - 6250) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres (2,5 - 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres (2,5 - 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla\nZakres (2,5 - 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04","parameters_zh":[{"name":"范围","range":"(2,5 - 6250) mg/m3"}],"search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9c4f1c10c8ce825ff67","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 - 21) %"}],"parameters_en":[{"name":"Range","range":"(0,5 - 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (0,5 - 21) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,5 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (0,5 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(0,5 - 21) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a5dc9c4f1c10c8ce825ff68","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek na oznaczanie stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek na oznaczanie stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek na oznaczanie stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek na oznaczanie stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","search_zh":"废气 PN-EN 13649:2005","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff69","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff6a","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","methodology_en":"Sampling for determination of hydrogen chloride concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration PN-EN 1911:2011","search_zh":"废气 氯化氢浓度测定采样 PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce825ff6b","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie chlorowodoru","methodology_en":"Hydrogen chloride concentration","parameters":[{"name":"Zakres","range":"(0,1 - 5000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,1 - 5000) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorowodoru\nZakres (0,1 - 5000) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie chlorowodoru\nZakres (0,1 - 5000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie chlorowodoru\nZakres (0,1 - 5000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen chloride concentration Spectrophotometric method Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(0,1 - 5000) mg/m3"}],"search_zh":"废气 氯化氢浓度 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氯化氢浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff6c","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HCl (z obliczeń)","methodology_en":"HCl emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HCl emission (calculated) PN-EN 1911:2011","search_zh":"废气 HCl 排放（由计算得出） PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ff6d","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce825ff6e","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,2 – 50) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,2 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,2 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,2 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,2 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff6f","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff70","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczenia stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczenia stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczenia stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05","categories":["materials"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05","search_zh":"废气 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff71","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","methodology_en":"Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2025-05","categories":["materials","environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) PN-EN 14385:2025-05","search_zh":"废气 金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出） PN-EN 14385:2025-05","test_object_zh":"废气","methodology_zh":"金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ff72","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(4– 40) % obj."}],"parameters_en":[{"name":"Range","range":"(4– 40) % obj."}],"technique":"Metoda adsorpcyjna i kondensacyjno-adsorpcyjna","techniques":["Metoda adsorpcyjna i kondensacyjno-adsorpcyjna"],"technique_en":"Adsorption and condensation-adsorption method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (4– 40) % obj.\nMetoda adsorpcyjna i kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres (4– 40) % obj.\nMetoda adsorpcyjna i kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres (4– 40) % obj.\nMetoda adsorpcyjna i kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Water vapour concentration (H2O) Adsorption and condensation-adsorption method Range PN-EN 14790:2017-04","parameters_zh":[{"name":"范围","range":"(4– 40) % obj."}],"search_zh":"废气 水蒸气浓度（H2O） 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）"},{"_id":"6a5dc9c4f1c10c8ce825ff73","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania fluorowodoru","methodology_en":"Sampling for the determination of hydrogen fluoride","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania fluorowodoru","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania fluorowodoru ISO 15713:2006 CEN/TS 17340:2020-09 Gazy odlotowe Pobieranie probek do oznaczania fluorowodoru ISO 15713:2006 CEN/TS 17340:2020-09","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of hydrogen fluoride ISO 15713:2006 CEN/TS 17340:2020-09","search_zh":"废气 ISO 15713:2006 CEN/TS 17340:2020-09","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff74","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie fluorowodoru","methodology_en":"Hydrogen fluoride concentration","parameters":[{"name":"Zakres","range":"(0,02 - 200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,02 - 200) mg/m3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorowodoru\nZakres (0,02 - 200) mg/m3\nMetoda potencjometryczna","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie fluorowodoru\nZakres (0,02 - 200) mg/m3\nMetoda potencjometryczna ISO 15713:2006 CEN/TS 17340:2020-09 Gazy odlotowe Stezenie fluorowodoru\nZakres (0,02 - 200) mg/m3\nMetoda potencjometryczna ISO 15713:2006 CEN/TS 17340:2020-09","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen fluoride concentration Potentiometric method Range ISO 15713:2006 CEN/TS 17340:2020-09","parameters_zh":[{"name":"范围","range":"(0,02 - 200) mg/m3"}],"search_zh":"废气 氟化氢浓度 电位法 范围 ISO 15713:2006 CEN/TS 17340:2020-09","technique_zh":"电位法","test_object_zh":"废气","methodology_zh":"氟化氢浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff75","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HF (z obliczeń)","methodology_en":"HF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 CEN/TS 17340:2020-09 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006 CEN/TS 17340:2020-09","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HF emission (calculated) ISO 15713:2006 CEN/TS 17340:2020-09","search_zh":"废气 HF 排放量（计算值） ISO 15713:2006 CEN/TS 17340:2020-09","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff76","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania dwutlenku siarki","methodology_en":"Sampling for determination of sulfur dioxide","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania dwutlenku siarki","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania dwutlenku siarki PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania dwutlenku siarki PN-EN 14791:2017-04","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of sulfur dioxide PN-EN 14791:2017-04","search_zh":"废气 PN-EN 14791:2017-04","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff77","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku siarki","methodology_en":"Sulphur dioxide concentration","parameters":[{"name":"Zakres","range":"(0,8 - 5000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,8 - 5000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki\nZakres (0,8 - 5000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki\nZakres (0,8 - 5000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie dwutlenku siarki\nZakres (0,8 - 5000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sulphur dioxide concentration Thoron method Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(0,8 - 5000) mg/m3"}],"search_zh":"废气 二氧化硫浓度 钍射气法 范围 PN-EN 14791:2017-04","test_object_zh":"废气","technique_zh":"钍射气法","methodology_zh":"二氧化硫浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff78","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja dwutlenku siarki (z obliczeń)","methodology_en":"Sulphur dioxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja dwutlenku siarki (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja dwutlenku siarki (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja dwutlenku siarki (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sulphur dioxide emission (calculated) PN-EN 14791:2017-04","search_zh":"废气 二氧化硫排放（由计算得出） PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"二氧化硫排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ff79","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania, H2SO4, SO3","methodology_en":"Sampling for determination of, H2SO4, SO3","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania, H2SO4, SO3","reference":"PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-2/Tech/10 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania, H2SO4, SO3 PB-2/Tech/10 wyd. B z dnia 08.01.2019 r. Gazy odlotowe Pobieranie probek do oznaczania, H2SO4, SO3 PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of, H2SO4, SO3 PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","search_zh":"废气 PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff7a","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie H2SO4, SO3","methodology_en":"H2SO4, SO3 concentration","parameters":[{"name":"Zakres","range":"(1,3 - 5000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,3 - 5000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie H2SO4, SO3\nZakres (1,3 - 5000) mg/m3\nMetoda toronowa","reference":"PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-2/Tech/10 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie H2SO4, SO3\nZakres (1,3 - 5000) mg/m3\nMetoda toronowa PB-2/Tech/10 wyd. B z dnia 08.01.2019 r. Gazy odlotowe Stezenie H2SO4, SO3\nZakres (1,3 - 5000) mg/m3\nMetoda toronowa PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases H2SO4, SO3 concentration Thoron method Range PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","parameters_zh":[{"name":"范围","range":"(1,3 - 5000) mg/m3"}],"search_zh":"废气 钍射气法 范围 PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a5dc9c4f1c10c8ce825ff7b","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja H2SO4, SO3 (z obliczeń)","methodology_en":"Emission of H2SO4, SO3 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja H2SO4, SO3 (z obliczeń)","reference":"PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-2/Tech/10 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja H2SO4, SO3 (z obliczeń) PB-2/Tech/10 wyd. B z dnia 08.01.2019 r. Gazy odlotowe Emisja H2SO4, SO3 (z obliczen) PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of H2SO4, SO3 (calculated) PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","search_zh":"废气 PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff7c","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","methodology_en":"Sampling for determination of total mercury concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of total mercury concentration PN-EN 13211+AC:2006","search_zh":"废气 总汞浓度测定采样 PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce825ff7d","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja rtęci (z obliczeń)","methodology_en":"Mercury emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja rtęci (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja rtęci (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Mercury emission (calculated) PN-EN 13211+AC:2006","search_zh":"废气 汞排放（由计算得出） PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"汞排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ff7e","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek PCDD/PCDF","methodology_en":"Sampling of PCDD/PCDF","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek PCDD/PCDF","reference":"PN-EN 1948-1:2006 +Ap1:2017-08","norm_bases":["PN-EN 1948-1:2006 +Ap1:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek PCDD/PCDF PN-EN 1948-1:2006 +Ap1:2017-08 Gazy odlotowe Pobieranie probek PCDD/PCDF PN-EN 1948-1:2006 +Ap1:2017-08","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling of PCDD/PCDF PN-EN 1948-1:2006 +Ap1:2017-08","search_zh":"废气 PN-EN 1948-1:2006 +Ap1:2017-08","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff7f","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja PCDD/PCDF (z obliczeń)","methodology_en":"PCDD/PCDF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja PCDD/PCDF (z obliczeń)","reference":"PN-EN 1948-1:2006 +Ap1:2017-08","norm_bases":["PN-EN 1948-1:2006 +Ap1:2017-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja PCDD/PCDF (z obliczeń) PN-EN 1948-1:2006 +Ap1:2017-08 Gazy odlotowe Emisja PCDD/PCDF (z obliczen) PN-EN 1948-1:2006 +Ap1:2017-08","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases PCDD/PCDF emission (calculated) PN-EN 1948-1:2006 +Ap1:2017-08","search_zh":"废气 PCDD/PCDF 排放（由计算得出） PN-EN 1948-1:2006 +Ap1:2017-08","test_object_zh":"废气","methodology_zh":"PCDD/PCDF 排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ff80","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(1,0 – 250) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 250) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowojonizacyjnej FID","techniques":["Metoda ciągłej detekcji płomieniowojonizacyjnej FID"],"technique_en":"Continuous flame ionization detection method FID","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 250) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej FID","reference":"PN- EN 12619:2013-05","norm_bases":["PN- EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 250) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej FID PN- EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,0 – 250) mg/m3\nMetoda ciaglej detekcji plomieniowojonizacyjnej FID PN- EN 12619:2013-05","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method FID Range PN- EN 12619:2013-05","parameters_zh":[{"name":"范围","range":"(1,0 – 250) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 范围 PN- EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff81","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN- EN 12619:2013-05","norm_bases":["PN- EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN- EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN- EN 12619:2013-05","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN- EN 12619:2013-05","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN- EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff82","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla, ditlenku węgla","methodology_en":"Concentration of carbon monoxide, carbon dioxide","parameters":[{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"CO2","range":"(0,5 – 25) %"}],"parameters_en":[{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"CO2","range":"(0,5 – 25) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla, ditlenku węgla\nZakres:\nCO (2,5 – 6250) mg/m3\nCO2 (0,5 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO-10396:2001 | EPA – Method 205:2019","norm_bases":["PN-ISO-10396:2001","EPA – Method 205:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla, ditlenku węgla\nZakres:\nCO (2,5 – 6250) mg/m3\nCO2 (0,5 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO-10396:2001 | EPA – Method 205:2019 Gazy odlotowe Stezenie tlenku wegla, ditlenku wegla\nZakres:\nCO (2,5 – 6250) mg/m3\nCO2 (0,5 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO-10396:2001 | EPA – Method 205:2019","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of carbon monoxide, carbon dioxide Non-dispersive infrared spectrometry (NDIR) CO CO2 PN-ISO-10396:2001 | EPA – Method 205:2019","search_zh":"废气 非分散红外光谱法（NDIR） CO CO2 PN-ISO-10396:2001 | EPA – Method 205:2019","test_object_zh":"废气","parameters_zh":[{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"CO2","range":"(0,5 – 25) %"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9c4f1c10c8ce825ff83","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla, ditlenku węgla","methodology_en":"Concentration of carbon monoxide, carbon dioxide","parameters":[{"name":"CO","range":"(6250 – 62500) mg/m3"},{"name":"CO2","range":"(25 – 100) %"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"CO","range":"(6250 – 62500) mg/m3"},{"name":"CO2","range":"(25 – 100) %"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla, ditlenku węgla\nZakres:\nCO (6250 – 62500) mg/m3\nCO2 (25 – 100) %\n(z obliczeń)","reference":"PN-ISO-10396:2001 | EPA – Method 205:2019","norm_bases":["PN-ISO-10396:2001","EPA – Method 205:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla, ditlenku węgla\nZakres:\nCO (6250 – 62500) mg/m3\nCO2 (25 – 100) %\n(z obliczeń) PN-ISO-10396:2001 | EPA – Method 205:2019 Gazy odlotowe Stezenie tlenku wegla, ditlenku wegla\nZakres:\nCO (6250 – 62500) mg/m3\nCO2 (25 – 100) %\n(z obliczen) PN-ISO-10396:2001 | EPA – Method 205:2019","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of carbon monoxide, carbon dioxide CO CO2 (calculated) PN-ISO-10396:2001 | EPA – Method 205:2019","parameters_zh":[{"name":"CO","range":"(6250 – 62500) mg/m3"},{"name":"CO2","range":"(25 – 100) %"},{"name":"（计算得出）"}],"search_zh":"废气 CO CO2 （计算得出） PN-ISO-10396:2001 | EPA – Method 205:2019","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff84","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,5 – 6250) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,5 – 6250) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres (2,5 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04 | EPA – Method 205:2019","norm_bases":["PN-EN 15058:2017-04","EPA – Method 205:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres (2,5 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 | EPA – Method 205:2019 Gazy odlotowe Stezenie tlenku wegla\nZakres (2,5 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 | EPA – Method 205:2019","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04 | EPA – Method 205:2019","parameters_zh":[{"name":"范围","range":"(2,5 – 6250) mg/m3"}],"search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04 | EPA – Method 205:2019","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9c4f1c10c8ce825ff85","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(6250 - 62500) mg/m3"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(6250 - 62500) mg/m3"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (6250 - 62500) mg/m3\n(z obliczeń)","reference":"PN-EN 15058:2017-04 | EPA – Method 205:2019","norm_bases":["PN-EN 15058:2017-04","EPA – Method 205:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres:\nZakres (6250 - 62500) mg/m3\n(z obliczeń) PN-EN 15058:2017-04 | EPA – Method 205:2019 Gazy odlotowe Stezenie tlenku wegla\nZakres:\nZakres (6250 - 62500) mg/m3\n(z obliczen) PN-EN 15058:2017-04 | EPA – Method 205:2019","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide concentration Range (calculated) PN-EN 15058:2017-04 | EPA – Method 205:2019","parameters_zh":[{"name":"范围","range":"(6250 - 62500) mg/m3"},{"name":"（计算得出）"}],"search_zh":"废气 一氧化碳浓度 范围 （计算得出） PN-EN 15058:2017-04 | EPA – Method 205:2019","test_object_zh":"废气","methodology_zh":"一氧化碳浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff86","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 - 23) %"}],"parameters_en":[{"name":"Range","range":"(0,5 - 23) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (0,5 - 23) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04 | EPA – Method 205:2019","norm_bases":["PN-EN 14789:2017-04","EPA – Method 205:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,5 - 23) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 | EPA – Method 205:2019 Gazy odlotowe Stezenie tlenu\nZakres (0,5 - 23) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 | EPA – Method 205:2019","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-EN 14789:2017-04 | EPA – Method 205:2019","parameters_zh":[{"name":"范围","range":"(0,5 - 23) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-EN 14789:2017-04 | EPA – Method 205:2019","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a5dc9c4f1c10c8ce825ff87","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(23 – 100) %"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(23 – 100) %"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres:\nZakres (23 – 100) %\n(z obliczeń)","reference":"PN-EN 14789:2017-04 | EPA – Method 205:2019","norm_bases":["PN-EN 14789:2017-04","EPA – Method 205:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres:\nZakres (23 – 100) %\n(z obliczeń) PN-EN 14789:2017-04 | EPA – Method 205:2019 Gazy odlotowe Stezenie tlenu\nZakres:\nZakres (23 – 100) %\n(z obliczen) PN-EN 14789:2017-04 | EPA – Method 205:2019","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Range (calculated) PN-EN 14789:2017-04 | EPA – Method 205:2019","parameters_zh":[{"name":"范围","range":"(23 – 100) %"},{"name":"（计算得出）"}],"search_zh":"废气 氧浓度 范围 （计算得出） PN-EN 14789:2017-04 | EPA – Method 205:2019","test_object_zh":"废气","methodology_zh":"氧浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff88","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","methodology_en":"Sampling for determination of ammonia concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03","search_zh":"废气 氨浓度测定采样 PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce825ff89","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie amoniaku","methodology_en":"Ammonia concentration","parameters":[{"name":"Zakres","range":"(0,02 – 600) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,02 – 600) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie amoniaku\nZakres (0,02 – 600) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie amoniaku\nZakres (0,02 – 600) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe Stezenie amoniaku\nZakres (0,02 – 600) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,02 – 600) mg/m3"}],"search_zh":"废气 氨浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氨浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff8a","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja amoniaku (z obliczeń)","methodology_en":"Ammonia emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03","search_zh":"废气 氨排放量（计算值） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨排放量（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff8b","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia siarkowodoru","methodology_en":"Sampling for determination of hydrogen sulphide concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia siarkowodoru","reference":"PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-05/Tech/12 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia siarkowodoru PB-05/Tech/12 wyd. B z dnia 08.01.2019 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia siarkowodoru PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of hydrogen sulphide concentration PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","search_zh":"废气 用于测定硫化氢浓度的采样 PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","test_object_zh":"废气","methodology_zh":"用于测定硫化氢浓度的采样"},{"_id":"6a5dc9c4f1c10c8ce825ff8c","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie siarkowodoru","methodology_en":"Hydrogen sulphide concentration","parameters":[{"name":"Zakres","range":"(2,0 – 450) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,0 – 450) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarkowodoru\nZakres (2,0 – 450) mg/m3\nMetoda spektrofotometryczna","reference":"PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-05/Tech/12 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie siarkowodoru\nZakres (2,0 – 450) mg/m3\nMetoda spektrofotometryczna PB-05/Tech/12 wyd. B z dnia 08.01.2019 r. Gazy odlotowe Stezenie siarkowodoru\nZakres (2,0 – 450) mg/m3\nMetoda spektrofotometryczna PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen sulphide concentration Spectrophotometric method Range PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","parameters_zh":[{"name":"范围","range":"(2,0 – 450) mg/m3"}],"search_zh":"废气 硫化氢浓度 分光光度法 范围 PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"硫化氢浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff8d","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja siarkowodoru (z obliczeń)","methodology_en":"Hydrogen sulphide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja siarkowodoru (z obliczeń)","reference":"PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-05/Tech/12 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja siarkowodoru (z obliczeń) PB-05/Tech/12 wyd. B z dnia 08.01.2019 r. Gazy odlotowe Emisja siarkowodoru (z obliczen) PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","categories":["environment"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen sulphide emission (calculated) PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","search_zh":"废气 硫化氢排放（由计算得出） PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","test_object_zh":"废气","methodology_zh":"硫化氢排放（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ff8e","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia rtęci całkowitej (metoda ONTARIO)","methodology_en":"Sampling for determination of total mercury concentration (ONTARIO method)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci całkowitej (metoda ONTARIO)","reference":"PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","norm_bases":["PB-06/Tech/12 wyd. C z dnia 21.11.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci całkowitej (metoda ONTARIO) PB-06/Tech/12 wyd. C z dnia 21.11.2019 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci calkowitej (metoda ONTARIO) PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of total mercury concentration (ONTARIO method) PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","search_zh":"废气 PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff8f","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja rtęci całkowitej (z obliczeń)","methodology_en":"Emission of total mercury (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja rtęci całkowitej (z obliczeń)","reference":"PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","norm_bases":["PB-06/Tech/12 wyd. C z dnia 21.11.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja rtęci całkowitej (z obliczeń) PB-06/Tech/12 wyd. C z dnia 21.11.2019 r. Gazy odlotowe Emisja rteci calkowitej (z obliczen) PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","categories":["environment"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of total mercury (calculated) PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","search_zh":"废气 PB-06/Tech/12 wyd. C z dnia 21.11.2019 r.","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff90","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu PM2,5 i PM10","methodology_en":"Sampling for determination of PM2,5 and PM10 dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu PM2,5 i PM10","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PM2,5 i PM10 PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PM2,5 i PM10 PN-Z-04030-7:1994","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of PM2,5 and PM10 dust concentration PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff91","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu PM2,5 i PM10","methodology_en":"Sampling for determination of PM2,5 and PM10 dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu PM2,5 i PM10","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PM2,5 i PM10 PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PM2,5 i PM10 PN-EN 13284-1:2018-02","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of PM2,5 and PM10 dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 PN-EN 13284-1:2018-02","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff92","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczenia stężenia metali: Se, Sn, Zn","methodology_en":"Sampling for determination of metal concentrations: Se, Sn, Zn","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczenia stężenia metali: Se, Sn, Zn","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia metali: Se, Sn, Zn PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczenia stezenia metali: Se, Sn, Zn PN-EN 14385:2025-05","categories":["materials"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations: Se, Sn, Zn PN-EN 14385:2025-05","search_zh":"废气 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff93","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali: Se, Sn, Zn (z obliczeń)","methodology_en":"Emission of metals: Se, Sn, Zn (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali: Se, Sn, Zn (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali: Se, Sn, Zn (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja metali: Se, Sn, Zn (z obliczen) PN-EN 14385:2025-05","categories":["materials","environment"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of metals: Se, Sn, Zn (calculated) PN-EN 14385:2025-05","search_zh":"废气 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff94","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie N2O","methodology_en":"N2O concentration","parameters":[{"name":"Zakres","range":"(1,0 – 130) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 130) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie N2O\nZakres (1,0 – 130) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie N2O\nZakres (1,0 – 130) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Gazy odlotowe Stezenie N2O\nZakres (1,0 – 130) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases N2O concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010","parameters_zh":[{"name":"范围","range":"(1,0 – 130) mg/m3"}],"search_zh":"废气 N2O 浓度 非分散红外光谱法（NDIR） 范围 PN-EN ISO 21258:2010","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff95","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia CH4","methodology_en":"Sampling for determination of CH4 concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia CH4","reference":"PN-EN ISO 25139:2011","norm_bases":["PN-EN ISO 25139:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia CH4 PN-EN ISO 25139:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia CH4 PN-EN ISO 25139:2011","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of CH4 concentration PN-EN ISO 25139:2011","search_zh":"废气 PN-EN ISO 25139:2011","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff96","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CH4 (z obliczeń)","methodology_en":"CH4 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CH4 (z obliczeń)","reference":"PN-EN ISO 25139:2011","norm_bases":["PN-EN ISO 25139:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CH4 (z obliczeń) PN-EN ISO 25139:2011 Gazy odlotowe Emisja CH4 (z obliczen) PN-EN ISO 25139:2011","categories":["environment"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CH4 emission (calculated) PN-EN ISO 25139:2011","search_zh":"废气 PN-EN ISO 25139:2011","test_object_zh":"废气"},{"_id":"6a5dc9c4f1c10c8ce825ff97","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających","test_object_en":"General environment - waste gas samples collected into absorbing solutions","methodology":"Zawartość chlorowodoru","methodology_en":"Hydrogen chloride content","parameters":[{"name":"Zakres","range":"(0,06 – 180) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,06 – 180) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość chlorowodoru\nZakres (0,06 – 180) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających Zawartość chlorowodoru\nZakres (0,06 – 180) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Srodowisko ogolne - probki gazow odlotowych pobranych do roztworow pochlaniajacych Zawartosc chlorowodoru\nZakres (0,06 – 180) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["environment"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - waste gas samples collected into absorbing solutions Hydrogen chloride content Spectrophotometric method Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(0,06 – 180) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氯化氢含量 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","methodology_zh":"氯化氢含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9c4f1c10c8ce825ff98","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających","test_object_en":"General environment - waste gas samples collected into absorbing solutions","methodology":"Zawartość SO2","methodology_en":"SO2 content","parameters":[{"name":"Zakres","range":"(0,4 – 500) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,4 – 500) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Zawartość SO2\nZakres (0,4 – 500) mg w próbce\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających Zawartość SO2\nZakres (0,4 – 500) mg w próbce\nMetoda toronowa PN-EN 14791:2017-04 Srodowisko ogolne - probki gazow odlotowych pobranych do roztworow pochlaniajacych Zawartosc SO2\nZakres (0,4 – 500) mg w probce\nMetoda toronowa PN-EN 14791:2017-04","categories":["environment"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - waste gas samples collected into absorbing solutions SO2 content Thoron method Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(0,4 – 500) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 钍射气法 范围 PN-EN 14791:2017-04","technique_zh":"钍射气法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9c4f1c10c8ce825ff99","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających","test_object_en":"General environment - waste gas samples collected into absorbing solutions","methodology":"Zawartość H2SO4 , SO3","methodology_en":"H2SO4 , SO3 content","parameters":[{"name":"Zakres","range":"(0,7 – 500) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,7 – 500) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Zawartość H2SO4 , SO3\nZakres (0,7 – 500) mg w próbce\nMetoda toronowa","reference":"PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-2/Tech/10 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających Zawartość H2SO4 , SO3\nZakres (0,7 – 500) mg w próbce\nMetoda toronowa PB-2/Tech/10 wyd. B z dnia 08.01.2019 r. Srodowisko ogolne - probki gazow odlotowych pobranych do roztworow pochlaniajacych Zawartosc H2SO4 , SO3\nZakres (0,7 – 500) mg w probce\nMetoda toronowa PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","categories":["environment"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - waste gas samples collected into absorbing solutions H2SO4 , SO3 content Thoron method Range PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","parameters_zh":[{"name":"范围","range":"(0,7 – 500) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 钍射气法 范围 PB-2/Tech/10 wyd. B z dnia 08.01.2019 r.","technique_zh":"钍射气法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9c4f1c10c8ce825ff9a","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających","test_object_en":"General environment - waste gas samples collected into absorbing solutions","methodology":"Zawartość HF","methodology_en":"HF content","parameters":[{"name":"Zakres","range":"(0,02 – 20) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,02 – 20) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Zawartość HF\nZakres (0,02 – 20) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających Zawartość HF\nZakres (0,02 – 20) mg w próbce\nMetoda potencjometryczna ISO 15713:2006 Srodowisko ogolne - probki gazow odlotowych pobranych do roztworow pochlaniajacych Zawartosc HF\nZakres (0,02 – 20) mg w probce\nMetoda potencjometryczna ISO 15713:2006","categories":["environment"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - waste gas samples collected into absorbing solutions HF content Potentiometric method Range ISO 15713:2006","parameters_zh":[{"name":"范围","range":"(0,02 – 20) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 电位法 范围 ISO 15713:2006","technique_zh":"电位法","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9c4f1c10c8ce825ff9b","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających","test_object_en":"General environment - waste gas samples collected into absorbing solutions","methodology":"Zawartość amoniaku","methodology_en":"Ammonia content","parameters":[{"name":"Zakres","range":"(0,008 – 40) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,008 – 40) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość amoniaku\nZakres (0,008 – 40) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających Zawartość amoniaku\nZakres (0,008 – 40) mg w próbce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Srodowisko ogolne - probki gazow odlotowych pobranych do roztworow pochlaniajacych Zawartosc amoniaku\nZakres (0,008 – 40) mg w probce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - waste gas samples collected into absorbing solutions Ammonia content Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,008 – 40) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氨含量 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","methodology_zh":"氨含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9c4f1c10c8ce825ff9c","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających","test_object_en":"General environment - waste gas samples collected into absorbing solutions","methodology":"Zawartość siarkowodoru","methodology_en":"Hydrogen sulphide content","parameters":[{"name":"Zakres","range":"(0,12 – 27,00) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,12 – 27,00) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość siarkowodoru\nZakres (0,12 – 27,00) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","norm_bases":["PB-05/Tech/12 wyd. B z dnia 08.01.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobranych do roztworów pochłaniających Zawartość siarkowodoru\nZakres (0,12 – 27,00) mg w próbce\nMetoda spektrofotometryczna PB-05/Tech/12 wyd. B z dnia 08.01.2019 r. Srodowisko ogolne - probki gazow odlotowych pobranych do roztworow pochlaniajacych Zawartosc siarkowodoru\nZakres (0,12 – 27,00) mg w probce\nMetoda spektrofotometryczna PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","categories":["environment"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - waste gas samples collected into absorbing solutions Hydrogen sulphide content Spectrophotometric method Range PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","parameters_zh":[{"name":"范围","range":"(0,12 – 27,00) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 硫化氢含量 分光光度法 范围 PB-05/Tech/12 wyd. B z dnia 08.01.2019 r.","technique_zh":"分光光度法","methodology_zh":"硫化氢含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9c4f1c10c8ce825ff9d","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(25 − 137) dB"}],"parameters_en":[{"name":"Range","range":"(25 − 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 − 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 − 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 − 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 − 137) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9c4f1c10c8ce825ff9e","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9c4f1c10c8ce825ff9f","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,0002 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,0002 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,0002 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PN-87/M-34129 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Stężenie pyłu\nZakres (0,0002 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A Urzadzenia odpylajace gazy odlotowe Stezenie pylu\nZakres (0,0002 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gas dedusting equipment Dust concentration Gravimetric method Range PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0002 – 100) g/m3"}],"search_zh":"废气除尘设备 粉尘浓度 重量法 范围 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","technique_zh":"重量法","test_object_zh":"废气除尘设备"},{"_id":"6a5dc9c4f1c10c8ce825ffa0","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Skuteczność odpylania (z obliczeń)","methodology_en":"Dust removal efficiency (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność odpylania (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02","PN-87/M-34129 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gas dedusting equipment Dust removal efficiency (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","search_zh":"废气除尘设备 除尘效率（由计算得出） PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 | PN-87/M-34129 metoda A","test_object_zh":"废气除尘设备","methodology_zh":"除尘效率（由计算得出）"},{"_id":"6a5dc9c4f1c10c8ce825ffa1","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: N2O, NH3, Hg","methodology_en":"AMS calibration (QAL2) for: N2O, NH3, Hg","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie: N2O, NH3, Hg","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: N2O, NH3, Hg PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: N2O, NH3, Hg PN-EN 14181:2015-02","categories":["metrology"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for: N2O, NH3, Hg PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce825ffa2","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczne kontrole sprawności (AST) w zakresie: N2O, NH3, Hg","methodology_en":"Annual surveillance tests (AST) for: N2O, NH3, Hg","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczne kontrole sprawności (AST) w zakresie: N2O, NH3, Hg","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne kontrole sprawności (AST) w zakresie: N2O, NH3, Hg PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczne kontrole sprawnosci (AST) w zakresie: N2O, NH3, Hg PN-EN 14181:2015-02","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance tests (AST) for: N2O, NH3, Hg PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce825ffa3","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie N2O","methodology_en":"N2O concentration","parameters":[{"name":"Zakres","range":"(1,0 – 130) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 130) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie N2O\nZakres (1,0 – 130) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie N2O\nZakres (1,0 – 130) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Automatyczne Systemy, Monitoringu (AMS) Stezenie N2O\nZakres (1,0 – 130) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) N2O concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010","parameters_zh":[{"name":"范围","range":"(1,0 – 130) mg/m3"}],"search_zh":"自动测量系统（AMS） N2O 浓度 非分散红外光谱法（NDIR） 范围 PN-EN ISO 21258:2010","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffa4","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NH3","methodology_en":"NH3 concentration","parameters":[{"name":"Zakres","range":"(0,02 – 600) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,02 – 600) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie NH3\nZakres (0,02 – 600) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NH3\nZakres (0,02 – 600) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Automatyczne Systemy, Monitoringu (AMS) Stezenie NH3\nZakres (0,02 – 600) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NH3 concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,02 – 600) mg/m3"}],"search_zh":"自动测量系统（AMS） NH3 浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"NH3 浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffa5","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","methodology_en":"Sampling for determination of total mercury concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Automatyczne Systemy, Monitoringu (AMS) Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Sampling for determination of total mercury concentration PN-EN 13211+AC:2006","search_zh":"自动测量系统（AMS） 总汞浓度测定采样 PN-EN 13211+AC:2006","test_object_zh":"自动测量系统（AMS）","methodology_zh":"总汞浓度测定采样"},{"_id":"6a5dc9c4f1c10c8ce825ffa6","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie rtęci ogólnej (z obliczeń)","methodology_en":"Total mercury concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Automatyczne Systemy, Monitoringu (AMS) Stezenie rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Total mercury concentration (calculated) PN-EN 13211+AC:2006","search_zh":"自动测量系统（AMS） PN-EN 13211+AC:2006","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce825ffa7","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: pyłu, NO, NOx, SO2, CO2 , HF, HCl, O2,CO, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"AMS calibration (QAL2) for: dust, NO, NOx, SO2, CO2 , HF, HCl, O2,CO, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie: pyłu, NO, NOx, SO2, CO2 , HF, HCl, O2,CO, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pyłu, NO, NOx, SO2, CO2 , HF, HCl, O2,CO, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pylu, NO, NOx, SO2, CO2 , HF, HCl, O2,CO, H2O, substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny PN-EN 14181:2015-02","categories":["metrology"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for: dust, NO, NOx, SO2, CO2 , HF, HCl, O2,CO, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce825ffa8","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczne kontrole sprawności (AST) w zakresie: pyłu, NO, NOx, SO2, CO2 , HF, HCl, O2, CO, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Annual surveillance tests (AST) for: dust, NO, NOx, SO2, CO2 , HF, HCl, O2, CO, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczne kontrole sprawności (AST) w zakresie: pyłu, NO, NOx, SO2, CO2 , HF, HCl, O2, CO, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne kontrole sprawności (AST) w zakresie: pyłu, NO, NOx, SO2, CO2 , HF, HCl, O2, CO, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczne kontrole sprawnosci (AST) w zakresie: pylu, NO, NOx, SO2, CO2 , HF, HCl, O2, CO, H2O, substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny PN-EN 14181:2015-02","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance tests (AST) for: dust, NO, NOx, SO2, CO2 , HF, HCl, O2, CO, H2O, organic substances in the form of gases and vapours expressed as total gaseous organic carbon PN-EN 14181:2015-02","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce825ffa9","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce825ffaa","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,2 – 50) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,2 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,2 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,2 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,2 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 50) mg/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9c4f1c10c8ce825ffab","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie tlenku azotu, tlenków azotu","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters":[{"name":"NO","range":"(2,7 - 1340) mg/m3"},{"name":"NOx","range":"(4,1 - 2050) mg/m3"}],"parameters_en":[{"name":"NO","range":"(2,7 - 1340) mg/m3"},{"name":"NOx","range":"(4,1 - 2050) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2,7 - 1340) mg/m3\nNOx (4,1 - 2050) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2,7 - 1340) mg/m3\nNOx (4,1 - 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (2,7 - 1340) mg/m3\nNOx (4,1 - 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04","categories":["other"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method NO NOx PN-EN 14792:2017-04","search_zh":"自动测量系统（AMS） 一氧化氮、氮氧化物浓度 化学发光法 NO NOx PN-EN 14792:2017-04","test_object_zh":"自动测量系统（AMS）","parameters_zh":[{"name":"NO","range":"(2,7 - 1340) mg/m3"},{"name":"NOx","range":"(4,1 - 2050) mg/m3"}],"technique_zh":"化学发光法","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffac","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie dwutlenku siarki","methodology_en":"Sulphur dioxide concentration","parameters":[{"name":"Zakres","range":"(0,8 – 5000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,8 – 5000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki\nZakres (0,8 – 5000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie dwutlenku siarki\nZakres (0,8 – 5000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie dwutlenku siarki\nZakres (0,8 – 5000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Sulphur dioxide concentration Thoron method Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(0,8 – 5000) mg/m3"}],"search_zh":"自动测量系统（AMS） 二氧化硫浓度 钍射气法 范围 PN-EN 14791:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"钍射气法","methodology_zh":"二氧化硫浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffad","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO2","methodology_en":"CO2 concentration","parameters":[{"name":"Zakres","range":"(0,5 – 25) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 25) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO2\nZakres (0,5 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO2\nZakres (0,5 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO2\nZakres (0,5 – 25) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO2 concentration Non-dispersive infrared spectrometry (NDIR) Range PN-ISO 10396:2001","parameters_zh":[{"name":"范围","range":"(0,5 – 25) %"}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外光谱法（NDIR） 范围 PN-ISO 10396:2001","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO2 浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffae","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie HF","methodology_en":"HF concentration","parameters":[{"name":"Zakres","range":"(0,02 - 200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,02 - 200) mg/m3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Stężenie HF\nZakres (0,02 - 200) mg/m3\nMetoda potencjometryczna","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie HF\nZakres (0,02 - 200) mg/m3\nMetoda potencjometryczna ISO 15713:2006 CEN/TS 17340:2020-09 Automatyczne Systemy, Monitoringu (AMS) Stezenie HF\nZakres (0,02 - 200) mg/m3\nMetoda potencjometryczna ISO 15713:2006 CEN/TS 17340:2020-09","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) HF concentration Potentiometric method Range ISO 15713:2006 CEN/TS 17340:2020-09","parameters_zh":[{"name":"范围","range":"(0,02 - 200) mg/m3"}],"search_zh":"自动测量系统（AMS） HF 浓度 电位法 范围 ISO 15713:2006 CEN/TS 17340:2020-09","technique_zh":"电位法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"HF 浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffaf","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO","methodology_en":"CO concentration","parameters":[{"name":"Zakres","range":"(2,5 – 6250) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,5 – 6250) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie CO\nZakres (2,5 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO\nZakres (2,5 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO\nZakres (2,5 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04","parameters_zh":[{"name":"范围","range":"(2,5 – 6250) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO 浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffb0","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie O2","methodology_en":"O2 concentration","parameters":[{"name":"Zakres","range":"(0,5 – 21) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie O2\nZakres (0,5 – 21) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie O2\nZakres (0,5 – 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie O2\nZakres (0,5 – 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) O2 concentration Paramagnetic method Range PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"(0,5 – 21) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法 范围 PN-EN 14789:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffb1","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie chlorowodoru","methodology_en":"Hydrogen chloride concentration","parameters":[{"name":"Zakres","range":"(0,1 – 5000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,1 – 5000) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorowodoru\nZakres (0,1 – 5000) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie chlorowodoru\nZakres (0,1 – 5000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Automatyczne Systemy, Monitoringu (AMS) Stezenie chlorowodoru\nZakres (0,1 – 5000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Hydrogen chloride concentration Spectrophotometric method Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(0,1 – 5000) mg/m3"}],"search_zh":"自动测量系统（AMS） 氯化氢浓度 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氯化氢浓度"},{"_id":"6a5dc9c4f1c10c8ce825ffb2","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(1,0 – 250) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 250) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)"],"technique_en":"Continuous flame ionization detection method (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 250) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID)","reference":"PN- EN 12619:2013-05","norm_bases":["PN- EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,0 – 250) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID) PN- EN 12619:2013-05 Automatyczne Systemy, Monitoringu (AMS) Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,0 – 250) mg/m3\nMetoda ciaglej detekcji plomieniowojonizacyjnej (FID) PN- EN 12619:2013-05","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN- EN 12619:2013-05","parameters_zh":[{"name":"范围","range":"(1,0 – 250) mg/m3"}],"search_zh":"自动测量系统（AMS） 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN- EN 12619:2013-05","test_object_zh":"自动测量系统（AMS）","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a5dc9c4f1c10c8ce825ffb3","lab_id":"69ad52a3de79e566650fb4e4","country":"PL","accr_number":"AB 974","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(4 – 40) % obj."}],"parameters_en":[{"name":"Range","range":"(4 – 40) % obj."}],"technique":"Metoda adsorpcyjna i kondensacyjno-adsorpcyjna","techniques":["Metoda adsorpcyjna i kondensacyjno-adsorpcyjna"],"technique_en":"Adsorption and condensation-adsorption method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (4 – 40) % obj.\nMetoda adsorpcyjna i kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pary wodnej (H2O)\nZakres (4 – 40) % obj.\nMetoda adsorpcyjna i kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie pary wodnej (H2O)\nZakres (4 – 40) % obj.\nMetoda adsorpcyjna i kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Water vapour concentration (H2O) Adsorption and condensation-adsorption method Range PN-EN 14790:2017-04","parameters_zh":[{"name":"范围","range":"(4 – 40) % obj."}],"search_zh":"自动测量系统（AMS） 水蒸气浓度（H2O） 范围 PN-EN 14790:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"水蒸气浓度（H2O）"}],"has_pdf":true}