{"lab":{"_id":"69ad52a3de79e566650fb4e2","accr_number":"AB 972","country":"PL","accr_body":"PCA","address":"GOSPODARKI WODNEJ I REKULTYWACJI S.A., ul. Chlebowa 22, 44-335 Jastrzębie Zdrój, LABORATORIUM BADAWCZE WODY I ŚCIEKÓW, ul. Piotra Skargi 9","categories":["water","microbiology"],"city":"Jastrzębie Zdrój","imported_at":"2026-03-08T10:42:43.265Z","methods_count":15,"name":"PRZEDSIĘBIORSTWO","parse_status":"parsed","parse_version":2,"pdf_files":["AB_972.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo gospodarki wodnej i rekultywacji s.a., ul. chlebowa 22, 44-335 jastrzębie zdrój, laboratorium badawcze wody i ścieków, ul. piotra skargi 9 water other pharma electronics","status":"active","updated_at":"2026-03-08T14:51:51.681Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:51.681Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20972,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"},{"codes":"P/28","pl":"Pobieranie próbek wody","en":"Sampling of water"}],"issue":{"no":"15","date":"01.10.2024"},"parse_date":"2026-07-20T07:09:58.884Z","parse_source":"script-pdfplumber","map_coord":[49.935267,18.584477],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":15,"microbiology":1},"category_scores":{"water":14.06,"microbiology":0.06},"has_zh":true},"methods":[{"_id":"6a5dc9c6f1c10c8ce82606da","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki wody"},{"name":"Zakres","range":"(1,0 – 45,0) 0C"}],"parameters_en":[{"name":"Temperature of the collected water sample"},{"name":"Range","range":"(1,0 – 45,0) 0C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (1,0 – 45,0) 0C\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6, 8.2 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6, 8.2","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (1,0 – 45,0) 0C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6, 8.2 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki wody\nZakres (1,0 – 45,0) 0C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.3, 7.5, 7.6, 8.2 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Manual method Temperature of the collected water sample Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6, 8.2 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采水样的温度"},{"name":"范围","range":"(1,0 – 45,0) 0C"}],"search_zh":"水 化学与物理检测用样品采集 手工法 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6, 8.2 | PN-77/C-04584","test_object_zh":"水","technique_zh":"手工法"},{"_id":"6a5dc9c6f1c10c8ce82606db","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda przemysłowa","test_object_en":"Industrial water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda przemysłowa Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda przemyslowa Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-ISO 5667-5:2017-10"},{"_id":"6a5dc9c6f1c10c8ce82606dc","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda przemysłowa","test_object_en":"Industrial water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.1.3; 4.4.1.4; 4.4.1.5; 4.4.2; 4.4.3; 4.4.4","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.1.3; 4.4.1.4; 4.4.1.5; 4.4.2; 4.4.3; 4.4.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda przemysłowa Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.1.3; 4.4.1.4; 4.4.1.5; 4.4.2; 4.4.3; 4.4.4 Woda przemyslowa Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt 4.4.1.3; 4.4.1.4; 4.4.1.5; 4.4.2; 4.4.3; 4.4.4","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Industrial water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.1.3; 4.4.1.4; 4.4.1.5; 4.4.2; 4.4.3; 4.4.4","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.1.3; 4.4.1.4; 4.4.1.5; 4.4.2; 4.4.3; 4.4.4"},{"_id":"6a5dc9c6f1c10c8ce82606dd","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","test_object_en":"Wastewater, Rainwater and snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(1,0 – 45,0) 0C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(1,0 – 45,0) 0C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 45,0) 0C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 45,0) 0C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki, Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (1,0 – 45,0) 0C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Rainwater and snowmelt water Sampling for chemical and physical testing Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(1,0 – 45,0) 0C"}],"search_zh":"废水、雨水与融雪水 化学与物理检测用样品采集 手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手工法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a5dc9c6f1c10c8ce82606de","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","test_object_en":"Wastewater, Rainwater and snowmelt water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l"}],"search_zh":"废水、雨水与融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a5dc9c6f1c10c8ce82606df","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Odczyn pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,5"}],"parameters_en":[{"name":"Range","range":"4,0 – 9,5"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Odczyn pH\nZakres 4,0 – 9,5\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Odczyn pH\nZakres 4,0 – 9,5\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki Odczyn pH\nZakres 4,0 – 9,5\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","parameters_zh":[{"name":"范围","range":"4,0 – 9,5"}],"search_zh":"水、废水 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9c6f1c10c8ce82606e0","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"od 100 μS/cm do 500 mS/cm"}],"parameters_en":[{"name":"Range","range":"od 100 μS/cm do 500 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres od 100 μS/cm do 500 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres od 100 μS/cm do 500 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres od 100 μS/cm do 500 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"od 100 μS/cm do 500 mS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a5dc9c6f1c10c8ce82606e1","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,00 – 100000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,00 – 100000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,00 – 100000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,00 – 100000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,00 – 100000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 100000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c6f1c10c8ce82606e2","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(5 - 3000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 - 3000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (5 - 3000) mg/l\nMetoda spektrofotometryczna","reference":"PBL-02 wyd. 3 z dnia 22.07.2024 r. | na podstawie testu kuwetowego HACH Metoda 8051","norm_bases":["PBL-02 wyd. 3 z dnia 22.07.2024 r.","na podstawie testu kuwetowego HACH Metoda 8051"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (5 - 3000) mg/l\nMetoda spektrofotometryczna PBL-02 wyd. 3 z dnia 22.07.2024 r. | na podstawie testu kuwetowego HACH Metoda 8051 Woda, scieki Stezenie siarczanow\nZakres (5 - 3000) mg/l\nMetoda spektrofotometryczna PBL-02 wyd. 3 z dnia 22.07.2024 r. | na podstawie testu kuwetowego HACH Metoda 8051","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Range PBL-02 wyd. 3 z dnia 22.07.2024 r. | na podstawie testu kuwetowego HACH Metoda 8051","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 - 3000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 范围 PBL-02 wyd. 3 z dnia 22.07.2024 r. | na podstawie testu kuwetowego HACH Metoda 8051","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c6f1c10c8ce82606e3","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 - 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9c6f1c10c8ce82606e4","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9c6f1c10c8ce82606e5","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne Zapotrzebowanie Tlenu","methodology_en":"Biochemical Oxygen Demand","parameters":[{"name":"BZT5, BZT2+5"},{"name":"Zakres","range":"(2,0 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5, BOD2+5"},{"name":"Range","range":"(2,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5, BZT2+5\nZakres (2,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5, BZT2+5\nZakres (2,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5, BZT2+5\nZakres (2,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical Oxygen Demand Electrochemical method BOD5, BOD2+5 Range PN-EN 1899-2:2002","parameters_zh":[{"name":"BOD5、BOD2+5"},{"name":"范围","range":"(2,0 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BOD5、BOD2+5 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"生化需氧量"},{"_id":"6a5dc9c6f1c10c8ce82606e6","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne Zapotrzebowanie Tlenu","methodology_en":"Biochemical Oxygen Demand","parameters":[{"name":"BZT5, BZT2+5"},{"name":"Zakres","range":"(3 – 3000) mg/l O2"}],"parameters_en":[{"name":"BOD5, BOD2+5"},{"name":"Range","range":"(3 – 3000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5, BZT2+5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical Oxygen Demand Electrochemical method BOD5, BOD2+5 Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"BOD5、BOD2+5"},{"name":"范围","range":"(3 – 3000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BOD5、BOD2+5 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"生化需氧量"},{"_id":"6a5dc9c6f1c10c8ce82606e7","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne Zapotrzebowanie Tlenu ChZTCr","methodology_en":"Chemical Oxygen Demand CODCr","parameters":[{"name":"Zakres","range":"(7 – 1000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(7 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne Zapotrzebowanie Tlenu ChZTCr\nZakres (7 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN ISO 15705:2005","norm_bases":["PN ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne Zapotrzebowanie Tlenu ChZTCr\nZakres (7 – 1000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005 Woda, scieki Chemiczne Zapotrzebowanie Tlenu ChZTCr\nZakres (7 – 1000) mg/l O2\nMetoda spektrofotometryczna PN ISO 15705:2005","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical Oxygen Demand CODCr Spectrophotometric method Range PN ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(7 – 1000) mg/l O2"}],"search_zh":"水、废水 分光光度法 范围 PN ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c6f1c10c8ce82606e8","lab_id":"69ad52a3de79e566650fb4e2","country":"PL","accr_number":"AB 972","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,2 – 20) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/l O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"}],"has_pdf":true}