{"lab":{"_id":"69ad52a3de79e566650fb4dc","accr_number":"AB 967","country":"PL","accr_body":"PCA","address":"KILIŃSKA, SAMPOLSKA, STĘPIEŃ SP. J., ul. Abrahama 15A, 80-307 Gdańsk","categories":["environment","construction"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":22,"name":"LABORATORIUM BADAŃ ŚRODOWISKOWYCH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_967.pdf"],"scope_summary":"","search_text":"laboratorium badań środowiskowych kilińska, sampolska, stępień sp. j., ul. abrahama 15a, 80-307 gdańsk environment other metrology materials construction electronics pharma","status":"active","updated_at":"2026-03-08T14:51:51.517Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:51.517Z","location":{"type":"Point","coordinates":[18.6466,54.352]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20967,podmiot.html","fields_of_testing":[{"codes":"A/5","pl":"Badania akustyczne i drgań - obiekty budowlane","en":"Acoustic and vibration tests - building products"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling – working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"22","date":"28.08.2025"},"parse_date":"2026-07-20T07:09:56.016Z","parse_source":"script-pdfplumber","map_coord":[54.391228,18.57357],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":22,"construction":2,"materials":1},"category_scores":{"environment":19.36,"construction":0.16,"materials":0.04},"has_zh":true},"methods":[{"_id":"6a5dc9c4f1c10c8ce825ff39","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(44,0 - 136,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(44,0 - 136,0) dB"}],"parameters_en":[{"name":"Range","range":"(44,0 - 136,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(44,0 - 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44,0 - 136,0) dB\nSzczytowy poziom dźwięku C\nZakres (44,0 - 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (44,0 - 136,0) dB\nSzczytowy poziom dźwięku C\nZakres (44,0 - 136,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (44,0 - 136,0) dB\nSzczytowy poziom dzwieku C\nZakres (44,0 - 136,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(44,0 - 136,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(44,0 - 136,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9c4f1c10c8ce825ff3a","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9c4f1c10c8ce825ff3b","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(23 - 80) dB"}],"parameters_en":[{"name":"Range","range":"(23 - 80) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (23 - 80) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (23 - 80) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (23 - 80) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-87/B-02156","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(23 - 80) dB"}],"search_zh":"住宅、集体居住与公共建筑内的房间 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 — 噪声"},{"_id":"6a5dc9c4f1c10c8ce825ff3c","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings - noise","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej - halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rooms in residential, collective residence and public utility buildings - noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住与公共建筑内的房间 — 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住与公共建筑内的房间 — 噪声"},{"_id":"6a5dc9c4f1c10c8ce825ff3d","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe frakcja wdychalna frakcja respirabilna"},{"name":"azbest włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókiem ceramicznych włókna respirabilne"},{"name":"metale i ich związki, w tym frakcja wdychalna frakcja respirabilna"}],"parameters_en":[{"name":"dust agents inhalable fraction respirable fraction"},{"name":"asbestos respirable fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres respirable fibres"},{"name":"metals and their compounds, including inhalable fraction respirable fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nazbest włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókiem ceramicznych włókna respirabilne\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nazbest włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókiem ceramicznych włókna respirabilne\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe frakcja wdychalna frakcja respirabilna\nazbest wlokna respirabilne\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokiem ceramicznych wlokna respirabilne\nmetale i ich zwiazki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction asbestos respirable fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因子 可吸入性粉尘 呼吸性粉尘 金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因子 可吸入性粉尘 呼吸性粉尘"},{"name":"azbest włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókiem ceramicznych włókna respirabilne"},{"name":"金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘"}]},{"_id":"6a5dc9c4f1c10c8ce825ff3e","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"substancje organiczne, w tym frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna"}],"parameters_en":[{"name":"organic substances, including inhalable fraction"},{"name":"inorganic substances, including inhalable fraction respirable fraction thoracic fraction"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"technique_en":"Personal dosimetry method; Stationary method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction PN-Z-04008-7:2002+Az1:2004","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 有机物质，其中包括可吸入性粉尘 无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","technique_zh":"个体剂量测定法；定点测定法","parameters_zh":[{"name":"有机物质，其中包括可吸入性粉尘"},{"name":"无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘"}]},{"_id":"6a5dc9c4f1c10c8ce825ff3f","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9c4f1c10c8ce825ff40","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja wdychalna","methodology_en":"Concentration of harmful dust agents- inhalable fraction","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Zakres","range":"(0,20 – 20,42) mg/m3"}],"parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Range","range":"(0,20 – 20,42) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nZakres (0,20 – 20,42) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nZakres (0,20 – 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nZakres (0,20 – 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents- inhalable fraction Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"范围","range":"(0,20 – 20,42) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9c4f1c10c8ce825ff41","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 - 22) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,10 - 22) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 - 22) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 - 22) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,10 - 22) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method Apatites and phosphorites Portland cement Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 - 22) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a5dc9c4f1c10c8ce825ff42","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,32- 117) mg/m3"},{"name":"Zakres","range":"(2- 100) ppm"}],"parameters_en":[{"name":"Range","range":"(2,32- 117) mg/m3"},{"name":"Range","range":"(2- 100) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,32- 117) mg/m3\nZakres (2- 100) ppm\nMetoda elektrochemiczna","reference":"LBŚ-PB-7 wydanie 2 z dnia 03.09.2015 r.","norm_bases":["LBŚ-PB-7 wydanie 2 z dnia 03.09.2015 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,32- 117) mg/m3\nZakres (2- 100) ppm\nMetoda elektrochemiczna LBŚ-PB-7 wydanie 2 z dnia 03.09.2015 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,32- 117) mg/m3\nZakres (2- 100) ppm\nMetoda elektrochemiczna LBS-PB-7 wydanie 2 z dnia 03.09.2015 r.","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range Range LBŚ-PB-7 wydanie 2 z dnia 03.09.2015 r.","parameters_zh":[{"name":"范围","range":"(2,32- 117) mg/m3"},{"name":"范围","range":"(2- 100) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 LBŚ-PB-7 wydanie 2 z dnia 03.09.2015 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a5dc9c4f1c10c8ce825ff43","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - drgania, działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment - hand-transmitted vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenia drgań","methodology_en":"Root-mean-square frequency-weighted vibration accelerations","parameters":[{"name":"Zakres","range":"(0,3 - 50) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,3 - 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenia drgań\nZakres (0,3 - 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania, działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenia drgań\nZakres (0,3 - 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy - drgania, dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenia drgan\nZakres (0,3 - 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hand-transmitted vibration Root-mean-square frequency-weighted vibration accelerations Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","parameters_zh":[{"name":"范围","range":"(0,3 - 50) m/s2"}],"search_zh":"频率计权有效振动加速度 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_zh":"直接测量法","methodology_zh":"频率计权有效振动加速度"},{"_id":"6a5dc9c4f1c10c8ce825ff44","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - drgania, działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment - hand-transmitted vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania, działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy - drgania, dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hand-transmitted vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11"},{"_id":"6a5dc9c4f1c10c8ce825ff45","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenia drgań","methodology_en":"Root-mean-square frequency-weighted vibration accelerations","parameters":[{"name":"Zakres","range":"(0,02 - 20) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,02 - 20) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenia drgań\nZakres (0,02 - 20) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenia drgań\nZakres (0,02 - 20) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenia drgan\nZakres (0,02 - 20) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - whole-body vibration Root-mean-square frequency-weighted vibration accelerations Direct measurement method Range PN-EN 14253+A1:2011","parameters_zh":[{"name":"范围","range":"(0,02 - 20) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权有效振动加速度 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"频率计权有效振动加速度"},{"_id":"6a5dc9c4f1c10c8ce825ff46","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff47","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach i na zewnątrz","test_object_en":"Workplace environment - indoor and outdoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(10 - 10000) lx"}],"parameters_en":[{"name":"Range","range":"(10 - 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (10 - 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach i na zewnątrz Natężenie oświetlenia\nZakres (10 - 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach i na zewnatrz Natezenie oswietlenia\nZakres (10 - 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor and outdoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(10 - 10000) lx"}],"search_zh":"工作环境 － 室内与室外电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作环境 － 室内与室外电气照明"},{"_id":"6a5dc9c4f1c10c8ce825ff48","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach i na zewnątrz","test_object_en":"Workplace environment - indoor and outdoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach i na zewnątrz Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach i na zewnatrz Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor and outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 室内与室外电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作环境 － 室内与室外电气照明"},{"_id":"6a5dc9c4f1c10c8ce825ff49","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","test_object_en":"Workplace environment - moderate microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(5 - 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(5 – 50) °C"},{"name":"Wilgotność"},{"name":"Zakres","range":"(25 - 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 5) m/s"}],"parameters_en":[{"name":"Range","range":"(5 - 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(5 – 50) °C"},{"name":"Humidity"},{"name":"Range","range":"(25 - 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 - 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 50) °C\nWilgotność\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 - 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 50) °C\nWilgotność\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 - 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 50) °C\nWilgotnosc\nZakres (25 - 75) %\nPredkosc powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Humidity Range Air velocity Range PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 - 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(5 – 50) °C"},{"name":"湿度"},{"name":"范围","range":"(25 - 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 5) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 湿度 范围 空气流速 范围 PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9c4f1c10c8ce825ff4a","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","test_object_en":"Workplace environment - moderate microclimate","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index, PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9c4f1c10c8ce825ff4b","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","test_object_en":"Workplace environment - cold microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 - 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 5) m/s"}],"parameters_en":[{"name":"Range","range":"(-30 - 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 - 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 - 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (25 - 75) %\nPrędkość powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotnosc powietrza\nZakres (25 - 75) %\nPredkosc powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 - 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 - 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 - 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 5) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a5dc9c4f1c10c8ce825ff4c","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","test_object_en":"Workplace environment - cold microclimate","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a5dc9c4f1c10c8ce825ff4d","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","test_object_en":"Workplace environment - hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 - 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 - 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 50) °C"}],"parameters_en":[{"name":"Range","range":"(10 - 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 - 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 50) °C\nTemperatura wilgotna naturalna\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 - 50) °C\nTemperatura wilgotna naturalna\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 - 50) °C\nTemperatura wilgotna naturalna\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 - 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 50) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9c4f1c10c8ce825ff4e","lab_id":"69ad52a3de79e566650fb4dc","country":"PL","accr_number":"AB 967","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","test_object_en":"Workplace environment - hot microclimate","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff z obliczeń)","methodology_en":"WBGT index, WBGTeff index calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index calculated) PN-EN ISO 7243:2018-01","search_zh":"工作场所环境 — 高温微气候 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"}],"has_pdf":true}