{"lab":{"_id":"69ad52a3de79e566650fb4da","accr_number":"AB 965","country":"PL","accr_body":"PCA","address":"ul. Nowy Świat 2a, 62-800 Kalisz, LABORATORIUM, Kuchary 52","categories":["water","environment","materials"],"city":"Kalisz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":30,"name":"SPÓŁKA WODNO-ŚCIEKOWA „PROSNA”","parse_status":"parsed","parse_version":2,"pdf_files":["AB_965.pdf"],"scope_summary":"","search_text":"spółka wodno-ściekowa „prosna” ul. nowy świat 2a, 62-800 kalisz, laboratorium, kuchary 52 water other materials microbiology environment","status":"active","updated_at":"2026-03-08T14:51:51.448Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:13:23.166Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20965,podmiot.html","fields_of_testing":[{"codes":"C/30/P; C/31/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek ścieków, gleby, osadów","en":"Chemical tests and sampling of sewage, soil, sediments"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków, gleby, osadów","en":"Tests of physical properties and sampling of sewage, soil, sediments"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"P/32","pl":"Pobieranie próbek osadów ściekowych do badań biologicznych","en":"Sampling of sediments for biological tests"}],"issue":{"no":"19","date":"01.07.2026"},"parse_date":"2026-08-13T08:13:23.166Z","parse_source":"agent-claude-code","map_coord":[51.75767,18.084293],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium; Kuchary 52, 63-322 Gołuchów","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/a316a55f477541169f6632d04d84f81e/AB%20965.pdf","has_en":true,"category_counts":{"water":24,"environment":6,"materials":3},"category_scores":{"water":17.45,"environment":1.09,"materials":0.27},"has_zh":true,"lab_locations_zh":[{"name":"实验室；Kuchary 52, 63-322 Gołuchów","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7ca30636ba417e41c80a","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 600) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 600) mg/l\nMetoda spektrofotometryczna","reference":"PB-14/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 304 i LCK 303","norm_bases":["PB-14/2012 wydanie 2 z dnia 07.01.2014 r.","na podstawie testów HACH LANGE LCK 304 i LCK 303"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu amonowego\nZakres (0,05 – 600) mg/l\nMetoda spektrofotometryczna PB-14/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 304 i LCK 303 Scieki, woda Stezenie azotu amonowego\nZakres (0,05 – 600) mg/l\nMetoda spektrofotometryczna PB-14/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testow HACH LANGE LCK 304 i LCK 303","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 600) mg/l"}],"search_en":"Wastewater, water Ammonium nitrogen concentration Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-14/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 304 i LCK 303","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 600) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-14/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 304 i LCK 303","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c80b","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,1 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,1 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576-08","norm_bases":["PN-82/C-04576-08"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu azotanowego\nZakres (0,1 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576-08 Scieki, woda Stezenie azotu azotanowego\nZakres (0,1 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576-08","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,1 – 50) mg/l"}],"search_en":"Wastewater, water Nitrate nitrogen concentration Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-82/C-04576-08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 50) mg/l"}],"search_zh":"废水、水 硝态氮浓度 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-82/C-04576-08","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c80c","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(2,00 – 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (2,00 – 1000) mg/l\nMetoda spektrofotometryczna","reference":"PB-16/2012 wydanie 3 z dnia 25.06.2018 r. | na podstawie testów HACH LANGE LCK 138 i LCK 338","norm_bases":["PB-16/2012 wydanie 3 z dnia 25.06.2018 r.","na podstawie testów HACH LANGE LCK 138 i LCK 338"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu ogólnego\nZakres (2,00 – 1000) mg/l\nMetoda spektrofotometryczna PB-16/2012 wydanie 3 z dnia 25.06.2018 r. | na podstawie testów HACH LANGE LCK 138 i LCK 338 Scieki, woda Stezenie azotu ogolnego\nZakres (2,00 – 1000) mg/l\nMetoda spektrofotometryczna PB-16/2012 wydanie 3 z dnia 25.06.2018 r. | na podstawie testow HACH LANGE LCK 138 i LCK 338","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,00 – 1000) mg/l"}],"search_en":"Wastewater, water Total nitrogen concentration Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-16/2012 wydanie 3 z dnia 25.06.2018 r. | na podstawie testów HACH LANGE LCK 138 i LCK 338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(2,00 – 1000) mg/l"}],"search_zh":"废水、水 总氮浓度 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-16/2012 wydanie 3 z dnia 25.06.2018 r. | na podstawie testów HACH LANGE LCK 138 i LCK 338","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c80d","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 500) mg/l\nMetoda spektrofotometryczna","reference":"PB-17/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 349 i LCK 350","norm_bases":["PB-17/2012 wydanie 2 z dnia 07.01.2014 r.","na podstawie testów HACH LANGE LCK 349 i LCK 350"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie fosforu ogólnego\nZakres (0,05 – 500) mg/l\nMetoda spektrofotometryczna PB-17/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 349 i LCK 350 Scieki, woda Stezenie fosforu ogolnego\nZakres (0,05 – 500) mg/l\nMetoda spektrofotometryczna PB-17/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testow HACH LANGE LCK 349 i LCK 350","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 500) mg/l"}],"search_en":"Wastewater, water Total phosphorus concentration Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-17/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 349 i LCK 350","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 500) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-17/2012 wydanie 2 z dnia 07.01.2014 r. | na podstawie testów HACH LANGE LCK 349 i LCK 350","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c80e","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3,0 – 6000) mg/l O2"}],"search_en":"Wastewater, water Biochemical oxygen demand Electrochemical method Laboratory; Kuchary 52, 63-322 Gołuchów BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater, water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3,0 – 6000) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 实验室；Kuchary 52, 63-322 Gołuchów BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c80f","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(5 – 100000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5 – 100000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5 – 100000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5 – 100000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(5 – 100000) mg/l O2"}],"search_en":"Wastewater, water Chemical oxygen demand Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(5 – 100000) mg/l O2"}],"search_zh":"废水、水 化学需氧量（COD） 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"化学需氧量（COD）","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c810","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(7 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (7 – 500) mg/l\nMetoda spektrofotometryczna","reference":"PB-18/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8051","norm_bases":["PB-18/2012 wydanie 1 z dnia 25.06.2012 r.","na podstawie testów HACH 8051"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie siarczanów\nZakres (7 – 500) mg/l\nMetoda spektrofotometryczna PB-18/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8051 Scieki, woda Stezenie siarczanow\nZakres (7 – 500) mg/l\nMetoda spektrofotometryczna PB-18/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testow HACH 8051","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(7 – 500) mg/l"}],"search_en":"Wastewater, water Sulfate concentration Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-18/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8051","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(7 – 500) mg/l"}],"search_zh":"废水、水 硫酸盐浓度 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-18/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8051","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c811","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (10 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie chlorków\nZakres (10 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, woda Stezenie chlorkow\nZakres (10 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Wastewater, water Chloride concentration Titrimetric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater, water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"废水、水 氯化物浓度 滴定法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c812","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Wastewater, water Total suspended solids (TSS) Gravimetric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c813","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie metali","parameters":[{"name":"Ołów","range":"(0,05 – 10) mg/l"},{"name":"Miedź","range":"(0,05 – 6,00) mg/l"},{"name":"Cynk","range":"(0,025 – 50) mg/l"},{"name":"Kadm","range":"(0,05 – 2,00) mg/l"},{"name":"Nikiel","range":"(0,05 – 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nOłów (0,05 – 10) mg/l\nMiedź (0,05 – 6,00) mg/l\nCynk (0,025 – 50) mg/l\nKadm (0,05 – 2,00) mg/l\nNikiel (0,05 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie metali\nZakres:\nOłów (0,05 – 10) mg/l\nMiedź (0,05 – 6,00) mg/l\nCynk (0,025 – 50) mg/l\nKadm (0,05 – 2,00) mg/l\nNikiel (0,05 – 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Scieki, woda Stezenie metali\nZakres:\nOlow (0,05 – 10) mg/l\nMiedz (0,05 – 6,00) mg/l\nCynk (0,025 – 50) mg/l\nKadm (0,05 – 2,00) mg/l\nNikiel (0,05 – 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["materials","water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Metal concentrations","parameters_en":[{"name":"Lead","range":"(0,05 – 10) mg/l"},{"name":"Copper","range":"(0,05 – 6,00) mg/l"},{"name":"Zinc","range":"(0,025 – 50) mg/l"},{"name":"Cadmium","range":"(0,05 – 2,00) mg/l"},{"name":"Nickel","range":"(0,05 – 10) mg/l"}],"search_en":"Wastewater, water Metal concentrations Flame atomic absorption spectrometry (FAAS) Laboratory; Kuchary 52, 63-322 Gołuchów Lead Copper Zinc Cadmium Nickel PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater, water","methodology_zh":"金属浓度","parameters_zh":[{"name":"铅","range":"(0,05 – 10) mg/l"},{"name":"铜","range":"(0,05 – 6,00) mg/l"},{"name":"锌","range":"(0,025 – 50) mg/l"},{"name":"镉","range":"(0,05 – 2,00) mg/l"},{"name":"镍","range":"(0,05 – 10) mg/l"}],"search_zh":"废水、水 金属浓度 火焰原子吸收光谱法（FAAS） 实验室；Kuchary 52, 63-322 Gołuchów 铅 铜 锌 镉 镍 PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c814","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie chromu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu ogólnego\nZakres (0,10 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-10/2008 wydanie 1 z dnia 10.03.2008 r.","norm_bases":["PB-10/2008 wydanie 1 z dnia 10.03.2008 r."],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie chromu ogólnego\nZakres (0,10 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10/2008 wydanie 1 z dnia 10.03.2008 r. Scieki, woda Stezenie chromu ogolnego\nZakres (0,10 – 50) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10/2008 wydanie 1 z dnia 10.03.2008 r.","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Total chromium concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"search_en":"Wastewater, water Total chromium concentration Flame atomic absorption spectrometry (FAAS) Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-10/2008 wydanie 1 z dnia 10.03.2008 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater, water","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"废水、水 总铬浓度 火焰原子吸收光谱法（FAAS） 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-10/2008 wydanie 1 z dnia 10.03.2008 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów","methodology_zh":"总铬浓度"},{"_id":"6a7d7ca30636ba417e41c815","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,20 – 50) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,20 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-09/2007 wydanie 1 z dnia 28.06.2007 r.","norm_bases":["PB-09/2007 wydanie 1 z dnia 28.06.2007 r."],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie żelaza\nZakres (0,20 – 50) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-09/2007 wydanie 1 z dnia 28.06.2007 r. Scieki, woda Stezenie zelaza\nZakres (0,20 – 50) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-09/2007 wydanie 1 z dnia 28.06.2007 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,20 – 50) mg/l"}],"search_en":"Wastewater, water Iron concentration Flame atomic absorption spectrometry (FAAS) Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-09/2007 wydanie 1 z dnia 28.06.2007 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater, water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 50) mg/l"}],"search_zh":"废水、水 铁浓度 火焰原子吸收光谱法（FAAS） 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-09/2007 wydanie 1 z dnia 28.06.2007 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c816","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-20/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8507","norm_bases":["PB-20/2012 wydanie 1 z dnia 25.06.2012 r.","na podstawie testów HACH 8507"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda Stężenie azotu azotynowego\nZakres (0,010 – 3,00) mg/l\nMetoda spektrofotometryczna PB-20/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8507 Scieki, woda Stezenie azotu azotynowego\nZakres (0,010 – 3,00) mg/l\nMetoda spektrofotometryczna PB-20/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testow HACH 8507","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 3,00) mg/l"}],"search_en":"Wastewater, water Nitrite nitrogen concentration Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-20/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8507","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 3,00) mg/l"}],"search_zh":"废水、水 亚硝态氮浓度 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-20/2012 wydanie 1 z dnia 25.06.2012 r. | na podstawie testów HACH 8507","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c817","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki, woda","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Wastewater, water pH Potentiometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater, water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"废水、水 pH 值 电位法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c818","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater and snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"雨水与融雪水 总悬浮物 重量法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów","test_object_zh":"雨水与融雪水"},{"_id":"6a7d7ca30636ba417e41c819","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-EN ISO 5667-10:2021-11","norm_bases":["PN-EN ISO 5667-10:2021-11"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-EN ISO 5667-10:2021-11 Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-EN ISO 5667-10:2021-11","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Sampling for chemical and physical testing","search_en":"Rainwater and snowmelt water Sampling for chemical and physical testing Manual method Laboratory; Kuchary 52, 63-322 Gołuchów PN-EN ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Rainwater and snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水与融雪水 化学与物理检测用样品采集 手工法 实验室；Kuchary 52, 63-322 Gołuchów PN-EN ISO 5667-10:2021-11","technique_zh":"手工法","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów","test_object_zh":"雨水与融雪水"},{"_id":"6a7d7ca30636ba417e41c81a","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna i automatyczna","reference":"PN-EN ISO 5667-10:2021-11 | PB-05/2007 wydanie 1 z dnia 07.09.2007 r.","norm_bases":["PN-EN ISO 5667-10:2021-11","PB-05/2007 wydanie 1 z dnia 07.09.2007 r."],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna i automatyczna PN-EN ISO 5667-10:2021-11 | PB-05/2007 wydanie 1 z dnia 07.09.2007 r. Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C\nMetoda manualna i automatyczna PN-EN ISO 5667-10:2021-11 | PB-05/2007 wydanie 1 z dnia 07.09.2007 r.","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Laboratory; Kuchary 52, 63-322 Gołuchów Temperature Range PN-EN ISO 5667-10:2021-11 | PB-05/2007 wydanie 1 z dnia 07.09.2007 r.","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 实验室；Kuchary 52, 63-322 Gołuchów 温度 范围 PN-EN ISO 5667-10:2021-11 | PB-05/2007 wydanie 1 z dnia 07.09.2007 r.","test_object_zh":"污水","technique_zh":"手工与自动法","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c81b","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (0,5 – 50,0) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03","norm_bases":["PN-EN ISO 11465:2026-03"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres (0,5 – 50,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Osady sciekowe Sucha pozostalosc\nZakres (0,5 – 50,0) %\nMetoda wagowa PN-EN ISO 11465:2026-03","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,5 – 50,0) %"}],"search_en":"Sewage sludge Dry residue Gravimetric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN ISO 11465:2026-03","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) %"}],"search_zh":"污泥 干残渣 重量法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN ISO 11465:2026-03","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c81c","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)/Pozostałość po prażeniu suchej masy","parameters":[{"name":"Zakres","range":"(15,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)/Pozostałość po prażeniu suchej masy\nZakres (15,0 – 85,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)/Pozostałość po prażeniu suchej masy\nZakres (15,0 – 85,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI)/Pozostalosc po prazeniu suchej masy\nZakres (15,0 – 85,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Loss on ignition of dry matter (LOI)/Residue on ignition of dry matter","parameters_en":[{"name":"Range","range":"(15,0 – 85,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI)/Residue on ignition of dry matter Gravimetric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(15,0 – 85,0) %"}],"search_zh":"污泥 重量法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c81d","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali","parameters":[{"name":"Cynk","range":"(5,00 – 2500) mg/kg"},{"name":"Chrom ogólny","range":"(5,00 – 1000) mg/kg"},{"name":"Kadm","range":"(2,00 – 100) mg/kg"},{"name":"Nikiel","range":"(5,00 – 200) mg/kg"},{"name":"Miedź","range":"(5,00 – 1000) mg/kg"},{"name":"Ołów","range":"(5,00 – 500) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nCynk (5,00 – 2500) mg/kg\nChrom ogólny (5,00 – 1000) mg/kg\nKadm (2,00 – 100) mg/kg\nNikiel (5,00 – 200) mg/kg\nMiedź (5,00 – 1000) mg/kg\nOłów (5,00 – 500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 11047:2001 Metoda A","norm_bases":["PN-ISO 11047:2001 Metoda A"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali\nZakres:\nCynk (5,00 – 2500) mg/kg\nChrom ogólny (5,00 – 1000) mg/kg\nKadm (2,00 – 100) mg/kg\nNikiel (5,00 – 200) mg/kg\nMiedź (5,00 – 1000) mg/kg\nOłów (5,00 – 500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001 Metoda A Osady sciekowe Zawartosc metali\nZakres:\nCynk (5,00 – 2500) mg/kg\nChrom ogolny (5,00 – 1000) mg/kg\nKadm (2,00 – 100) mg/kg\nNikiel (5,00 – 200) mg/kg\nMiedz (5,00 – 1000) mg/kg\nOlow (5,00 – 500) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001 Metoda A","categories":["materials","water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Metal content","parameters_en":[{"name":"Zinc","range":"(5,00 – 2500) mg/kg"},{"name":"Total chromium","range":"(5,00 – 1000) mg/kg"},{"name":"Cadmium","range":"(2,00 – 100) mg/kg"},{"name":"Nickel","range":"(5,00 – 200) mg/kg"},{"name":"Copper","range":"(5,00 – 1000) mg/kg"},{"name":"Lead","range":"(5,00 – 500) mg/kg"}],"search_en":"Sewage sludge Metal content Flame atomic absorption spectrometry (FAAS) Laboratory; Kuchary 52, 63-322 Gołuchów Zinc Total chromium Cadmium Nickel Copper Lead PN-ISO 11047:2001 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"锌","range":"(5,00 – 2500) mg/kg"},{"name":"总铬","range":"(5,00 – 1000) mg/kg"},{"name":"镉","range":"(2,00 – 100) mg/kg"},{"name":"镍","range":"(5,00 – 200) mg/kg"},{"name":"铜","range":"(5,00 – 1000) mg/kg"},{"name":"铅","range":"(5,00 – 500) mg/kg"}],"search_zh":"污泥 金属含量 火焰原子吸收光谱法（FAAS） 实验室；Kuchary 52, 63-322 Gołuchów 锌 总铬 镉 镍 铜 铅 PN-ISO 11047:2001 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"金属含量","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c81e","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 – 14,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 2,0 – 14,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w H2O\nZakres 2,0 – 14,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres 2,0 – 14,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 – 14,0"}],"search_en":"Sewage sludge pH – in H2O Potentiometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"2,0 – 14,0"}],"search_zh":"污泥 pH — 于 H2O 中 电位法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a7d7ca30636ba417e41c81f","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość wapnia","parameters":[{"name":"Zakres","range":"(1,00 – 30,0) %"},{"name":"Zawartość magnezu"},{"name":"Zakres","range":"(0,10 – 5,00) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość wapnia\nZakres:\nZakres (1,00 – 30,0) %\nZawartość magnezu\nZakres (0,10 – 5,00) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-04/2006 wydanie 2 z dnia 01.06.2009 r.","norm_bases":["PB-04/2006 wydanie 2 z dnia 01.06.2009 r."],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość wapnia\nZakres:\nZakres (1,00 – 30,0) %\nZawartość magnezu\nZakres (0,10 – 5,00) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-04/2006 wydanie 2 z dnia 01.06.2009 r. Osady sciekowe Zawartosc wapnia\nZakres:\nZakres (1,00 – 30,0) %\nZawartosc magnezu\nZakres (0,10 – 5,00) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-04/2006 wydanie 2 z dnia 01.06.2009 r.","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Calcium content","parameters_en":[{"name":"Range","range":"(1,00 – 30,0) %"},{"name":"Magnesium content"},{"name":"Range","range":"(0,10 – 5,00) %"}],"search_en":"Sewage sludge Calcium content Flame atomic absorption spectrometry (FAAS) Laboratory; Kuchary 52, 63-322 Gołuchów Range Magnesium content Range PB-04/2006 wydanie 2 z dnia 01.06.2009 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,00 – 30,0) %"},{"name":"镁含量"},{"name":"范围","range":"(0,10 – 5,00) %"}],"search_zh":"污泥 钙含量 火焰原子吸收光谱法（FAAS） 实验室；Kuchary 52, 63-322 Gołuchów 范围 镁含量 范围 PB-04/2006 wydanie 2 z dnia 01.06.2009 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"钙含量","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c820","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005 – 20) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","norm_bases":["PB-13/2012 wydanie 1 z dnia 09.01.2012 r."],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość rtęci\nZakres (0,005 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-13/2012 wydanie 1 z dnia 09.01.2012 r. Osady sciekowe Zawartosc rteci\nZakres (0,005 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005 – 20) mg/kg"}],"search_en":"Sewage sludge Mercury content Atomic absorption spectrometry with amalgamation technique Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Sewage sludge","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005 – 20) mg/kg"}],"search_zh":"污泥 汞含量 原子吸收光谱法（汞齐化技术） 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"污泥","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c821","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Sampling for chemical, physical and biological testing","search_en":"Sewage sludge Sampling for chemical, physical and biological testing Laboratory; Kuchary 52, 63-322 Gołuchów PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","search_zh":"污泥 用于化学、物理与生物检验的采样 实验室；Kuchary 52, 63-322 Gołuchów PN-EN ISO 5667-13:2011","test_object_zh":"污泥","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów","methodology_zh":"用于化学、物理与生物检验的采样"},{"_id":"6a7d7ca30636ba417e41c822","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(70,0 – 99,9)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (70,0 – 99,9)%\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03","norm_bases":["PN-EN ISO 11465:2026-03"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa\nZakres (70,0 – 99,9)%\nMetoda wagowa PN-EN ISO 11465:2026-03 Gleba Sucha masa\nZakres (70,0 – 99,9)%\nMetoda wagowa PN-EN ISO 11465:2026-03","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(70,0 – 99,9)%"}],"search_en":"Soil Dry matter Gravimetric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN ISO 11465:2026-03","technique_en":"Gravimetric method","test_object_en":"Soil","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(70,0 – 99,9)%"}],"search_zh":"土壤 干物质 重量法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN ISO 11465:2026-03","technique_zh":"重量法","test_object_zh":"土壤","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c823","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Gleba","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH – w H2O\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH – w H2O\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Soil pH – in H2O Potentiometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"土壤 pH — 于 H2O 中 电位法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a7d7ca30636ba417e41c824","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość metali","parameters":[{"name":"Ołów","range":"(5,00 – 50,0) mg/kg"},{"name":"Kadm","range":"(0,80 – 10,0) mg/kg"},{"name":"Nikiel","range":"(5,00 – 200) mg/kg"},{"name":"Cynk","range":"(5,00 – 400) mg/kg"},{"name":"Miedź","range":"(2,00 – 150) mg/kg"},{"name":"Chrom ogólny","range":"(5,00 – 100) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nOłów (5,00 – 50,0) mg/kg\nKadm (0,80 – 10,0) mg/kg\nNikiel (5,00 – 200) mg/kg\nCynk (5,00 – 400) mg/kg\nMiedź (2,00 – 150) mg/kg\nChrom ogólny (5,00 – 100) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 16174:2012 Metoda B | PN-ISO 11047:2001 Metoda A","norm_bases":["PN-EN 16174:2012 Metoda B","PN-ISO 11047:2001 Metoda A"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość metali\nZakres:\nOłów (5,00 – 50,0) mg/kg\nKadm (0,80 – 10,0) mg/kg\nNikiel (5,00 – 200) mg/kg\nCynk (5,00 – 400) mg/kg\nMiedź (2,00 – 150) mg/kg\nChrom ogólny (5,00 – 100) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16174:2012 Metoda B | PN-ISO 11047:2001 Metoda A Gleba Zawartosc metali\nZakres:\nOlow (5,00 – 50,0) mg/kg\nKadm (0,80 – 10,0) mg/kg\nNikiel (5,00 – 200) mg/kg\nCynk (5,00 – 400) mg/kg\nMiedz (2,00 – 150) mg/kg\nChrom ogolny (5,00 – 100) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16174:2012 Metoda B | PN-ISO 11047:2001 Metoda A","categories":["materials","environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Metal content","parameters_en":[{"name":"Lead","range":"(5,00 – 50,0) mg/kg"},{"name":"Cadmium","range":"(0,80 – 10,0) mg/kg"},{"name":"Nickel","range":"(5,00 – 200) mg/kg"},{"name":"Zinc","range":"(5,00 – 400) mg/kg"},{"name":"Copper","range":"(2,00 – 150) mg/kg"},{"name":"Total chromium","range":"(5,00 – 100) mg/kg"}],"search_en":"Soil Metal content Flame atomic absorption spectrometry (FAAS) Laboratory; Kuchary 52, 63-322 Gołuchów Lead Cadmium Nickel Zinc Copper Total chromium PN-EN 16174:2012 Metoda B | PN-ISO 11047:2001 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Soil","parameters_zh":[{"name":"铅","range":"(5,00 – 50,0) mg/kg"},{"name":"镉","range":"(0,80 – 10,0) mg/kg"},{"name":"镍","range":"(5,00 – 200) mg/kg"},{"name":"锌","range":"(5,00 – 400) mg/kg"},{"name":"铜","range":"(2,00 – 150) mg/kg"},{"name":"总铬","range":"(5,00 – 100) mg/kg"}],"search_zh":"土壤 金属含量 火焰原子吸收光谱法（FAAS） 实验室；Kuchary 52, 63-322 Gołuchów 铅 镉 镍 锌 铜 总铬 PN-EN 16174:2012 Metoda B | PN-ISO 11047:2001 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"土壤","methodology_zh":"金属含量","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c825","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość fosforu przyswajalnego","parameters":[{"name":"Zakres","range":"(2,5 – 50,0) mg/100g"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (2,5 – 50,0) mg/100g\nMetoda spektrofotometryczna","reference":"PB-11/2009 wydanie 3 z dnia 01.04.2016 r.","norm_bases":["PB-11/2009 wydanie 3 z dnia 01.04.2016 r."],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość fosforu przyswajalnego\nZakres (2,5 – 50,0) mg/100g\nMetoda spektrofotometryczna PB-11/2009 wydanie 3 z dnia 01.04.2016 r. Gleba Zawartosc fosforu przyswajalnego\nZakres (2,5 – 50,0) mg/100g\nMetoda spektrofotometryczna PB-11/2009 wydanie 3 z dnia 01.04.2016 r.","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(2,5 – 50,0) mg/100g"}],"search_en":"Soil Available phosphorus content Spectrophotometric method Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-11/2009 wydanie 3 z dnia 01.04.2016 r.","technique_en":"Spectrophotometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(2,5 – 50,0) mg/100g"}],"search_zh":"土壤 有效磷含量 分光光度法 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-11/2009 wydanie 3 z dnia 01.04.2016 r.","technique_zh":"分光光度法","test_object_zh":"土壤","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów","methodology_zh":"有效磷含量"},{"_id":"6a7d7ca30636ba417e41c826","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,005 – 20) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,005 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","norm_bases":["PB-13/2012 wydanie 1 z dnia 09.01.2012 r."],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość rtęci\nZakres (0,005 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-13/2012 wydanie 1 z dnia 09.01.2012 r. Gleba Zawartosc rteci\nZakres (0,005 – 20) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,005 – 20) mg/kg"}],"search_en":"Soil Mercury content Atomic absorption spectrometry with amalgamation technique Laboratory; Kuchary 52, 63-322 Gołuchów Range PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Soil","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,005 – 20) mg/kg"}],"search_zh":"土壤 汞含量 原子吸收光谱法（汞齐化技术） 实验室；Kuchary 52, 63-322 Gołuchów 范围 PB-13/2012 wydanie 1 z dnia 09.01.2012 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"土壤","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"},{"_id":"6a7d7ca30636ba417e41c827","lab_id":"69ad52a3de79e566650fb4da","country":"PL","accr_number":"AB 965","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997","norm_bases":["PN-R-04031:1997"],"lab_section":"Laboratorium; Kuchary 52, 63-322 Gołuchów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Kuchary 52, 63-322 Gołuchów","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing Laboratory; Kuchary 52, 63-322 Gołuchów PN-R-04031:1997","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 实验室；Kuchary 52, 63-322 Gołuchów PN-R-04031:1997","test_object_zh":"土壤","lab_section_zh":"实验室；Kuchary 52, 63-322 Gołuchów"}],"has_pdf":true}