{"lab":{"_id":"69ad52a3de79e566650fb4d4","accr_number":"AB 961","country":"PL","accr_body":"PCA","address":"KROŚNIEŃSKI HOLDING KOMUNALNY Sp. z o.o., ul. Fredry 12, 38-400 Krosno, CENTRALNE LABORATORIUM WODY I ŚCIEKÓW, ul. Drzymały 14","categories":["water"],"city":"Krosno","imported_at":"2026-03-08T10:42:43.265Z","methods_count":21,"name":"MIEJSKIE PRZEDSIĘBIORSTWO GOSPODARKI KOMUNALNEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_961.pdf"],"scope_summary":"","search_text":"miejskie przedsiębiorstwo gospodarki komunalnej krośnieński holding komunalny sp. z o.o., ul. fredry 12, 38-400 krosno, centralne laboratorium wody i ścieków, ul. drzymały 14 water other materials","status":"active","updated_at":"2026-03-08T14:51:51.226Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:51.226Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20961,podmiot.html","fields_of_testing":[{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"}],"issue":{"no":"15","date":"09.10.2024"},"parse_date":"2026-07-20T07:09:55.885Z","parse_source":"script-pdfplumber","map_coord":[49.695886,21.770447],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":21,"materials":1},"category_scores":{"water":20.05,"materials":0.05},"has_zh":true},"methods":[{"_id":"6a5dc9c3f1c10c8ce825febd","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,0 – 35,0) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,0 – 35,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 35,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 35,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,0 – 35,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,0 – 35,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825febe","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","methodology_en":"Chemical oxygen demand − COD-Cr","parameters":[{"name":"Zakres","range":"(30 − 10 000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(30 − 10 000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 − 10 000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 − 10 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 − 10 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand − COD-Cr Titrimetric method Range PN-ISO 6060:2006","parameters_zh":[{"name":"范围","range":"(30 − 10 000) mg/l O2"}],"search_zh":"污水 化学需氧量 － COD-Cr 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a5dc9c3f1c10c8ce825febf","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,5 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,5 − 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,5 − 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,5 − 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,5 − 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,5 − 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec0","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,05 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec1","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 − 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1,0 − 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (1,0 − 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 1000) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec2","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 − 30) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 − 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,05 − 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,05 − 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,05 − 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 − 30) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec3","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,002 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,002 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,002 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,002 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 10,0) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec4","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,040 – 40,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN 6878:2006 pkt 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,040 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,040 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 40,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec5","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,005 – 40,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,005 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN 6878:2006 pkt 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie ortofosforanów\nZakres (0,005 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 pkt 4 +Ap1:2010+Ap2:2010 Scieki Stezenie ortofosforanow\nZakres (0,005 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,005 – 40,0) mg/l"}],"search_zh":"污水 正磷酸盐浓度 分光光度法 范围 PN-EN 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9c3f1c10c8ce825fec6","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 − 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (5,0 − 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,0 − 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 − 1000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec7","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 − 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 − 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,00 − 150) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,00 − 150) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,00 − 150) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 − 150) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec8","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fec9","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(5 − 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 − 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 − 500) mg/l\nMetoda wagowa","reference":"PB-01 wydanie 3 z dnia 05.06.2020 r.","norm_bases":["PB-01 wydanie 3 z dnia 05.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 − 500) mg/l\nMetoda wagowa PB-01 wydanie 3 z dnia 05.06.2020 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5 − 500) mg/l\nMetoda wagowa PB-01 wydanie 3 z dnia 05.06.2020 r.","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PB-01 wydanie 3 z dnia 05.06.2020 r.","parameters_zh":[{"name":"范围","range":"(5 − 500) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 范围 PB-01 wydanie 3 z dnia 05.06.2020 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9c3f1c10c8ce825feca","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 600) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 600) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 600) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 – 600) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 – 600) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 600) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9c3f1c10c8ce825fecb","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 − 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, woda pH\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 − 10,0"}],"search_zh":"废水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水"},{"_id":"6a5dc9c3f1c10c8ce825fecc","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","methodology_en":"Biochemical oxygen demand − BOD5","parameters":[{"name":"Zakres","range":"(1,0 − 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1,0 − 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 − 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 − 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 − 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Biochemical oxygen demand − BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1,0 − 6000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"废水、水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c3f1c10c8ce825fecd","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","methodology_en":"Chemical oxygen demand − COD-Cr","parameters":[{"name":"Zakres","range":"(5,0 − 50) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(5,0 − 50) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,0 − 50) mg/l O2\nMetoda miareczkowa","reference":"PB-16 wydanie 2 z dnia 05.06.2020 r.","norm_bases":["PB-16 wydanie 2 z dnia 05.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,0 − 50) mg/l O2\nMetoda miareczkowa PB-16 wydanie 2 z dnia 05.06.2020 r. Scieki, woda Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (5,0 − 50) mg/l O2\nMetoda miareczkowa PB-16 wydanie 2 z dnia 05.06.2020 r.","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Chemical oxygen demand − COD-Cr Titrimetric method Range PB-16 wydanie 2 z dnia 05.06.2020 r.","parameters_zh":[{"name":"范围","range":"(5,0 − 50) mg/l O2"}],"search_zh":"废水、水 化学需氧量 － COD-Cr 滴定法 范围 PB-16 wydanie 2 z dnia 05.06.2020 r.","technique_zh":"滴定法","test_object_zh":"废水、水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a5dc9c3f1c10c8ce825fece","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie metali:","methodology_en":"Metal concentrations:","parameters":[{"name":"Cd","range":"(0,040 − 10) mg/l"},{"name":"Zn","range":"(0,020 − 10) mg/l"},{"name":"Cu","range":"(0,020 − 10) mg/l"},{"name":"Pb","range":"(0,10 − 10) mg/l"},{"name":"Ni","range":"(0,050 − 10) mg/l"}],"parameters_en":[{"name":"Cd","range":"(0,040 − 10) mg/l"},{"name":"Zn","range":"(0,020 − 10) mg/l"},{"name":"Cu","range":"(0,020 − 10) mg/l"},{"name":"Pb","range":"(0,10 − 10) mg/l"},{"name":"Ni","range":"(0,050 − 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali:\nZakres:\nCd (0,040 − 10) mg/l\nZn (0,020 − 10) mg/l\nCu (0,020 − 10) mg/l\nPb (0,10 − 10) mg/l\nNi (0,050 − 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie metali:\nZakres:\nCd (0,040 − 10) mg/l\nZn (0,020 − 10) mg/l\nCu (0,020 − 10) mg/l\nPb (0,10 − 10) mg/l\nNi (0,050 − 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki, woda Stezenie metali:\nZakres:\nCd (0,040 − 10) mg/l\nZn (0,020 − 10) mg/l\nCu (0,020 − 10) mg/l\nPb (0,10 − 10) mg/l\nNi (0,050 − 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water","materials"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Metal concentrations: Flame atomic absorption spectrometry (FAAS) Cd Zn Cu Pb Ni PN-ISO 8288:2002 metoda A","parameters_zh":[{"name":"Cd","range":"(0,040 − 10) mg/l"},{"name":"Zn","range":"(0,020 − 10) mg/l"},{"name":"Cu","range":"(0,020 − 10) mg/l"},{"name":"Pb","range":"(0,10 − 10) mg/l"},{"name":"Ni","range":"(0,050 − 10) mg/l"}],"search_zh":"废水、水 金属浓度： 火焰原子吸收光谱法（FAAS） Cd Zn Cu Pb Ni PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水","methodology_zh":"金属浓度："},{"_id":"6a5dc9c3f1c10c8ce825fecf","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,5 − 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,5 − 50) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,5 − 50) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zawiesiny ogólne\nZakres (2,5 − 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne\nZakres (2,5 − 50) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,5 − 50) mg/l"}],"search_zh":"水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9c3f1c10c8ce825fed0","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 − 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 − 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 − 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków\nZakres (5,0 − 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow\nZakres (5,0 − 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 − 400) mg/l"}],"search_zh":"水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9c3f1c10c8ce825fed1","lab_id":"69ad52a3de79e566650fb4d4","country":"PL","accr_number":"AB 961","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 − 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 − 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 − 200) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów\nZakres (10 − 200) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda Stezenie siarczanow\nZakres (10 − 200) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 − 200) mg/l"}],"search_zh":"水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水"}],"has_pdf":true}