{"lab":{"_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","address":"ul. Leśników 21, Sękocin Stary, 05-090 Raszyn, BIURO URZĄDZANIA LASU I GEODEZJI LEŚNEJ, ODDZIAŁ W KRAKOWIE, LABORATORIUM GLEBOZNAWCZE","categories":["environment"],"city":"Raszyn","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"BIURO URZĄDZANIA LASU I GEODEZJI LEŚNEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_945.pdf"],"scope_summary":"","search_text":"biuro urządzania lasu i geodezji leśnej ul. leśników 21, sękocin stary, 05-090 raszyn, biuro urządzania lasu i geodezji leśnej, oddział w krakowie, laboratorium gleboznawcze environment other","status":"active","updated_at":"2026-03-08T14:51:50.577Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:50.577Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20945,podmiot.html","fields_of_testing":[{"codes":"C/31","pl":"Badania chemiczne gleby","en":"Chemical tests of soil"},{"codes":"N/31","pl":"Badania właściwości fizycznych gleby","en":"Tests of physical properties of soil"}],"issue":{"no":"14","date":"19.08.2024"},"parse_date":"2026-07-20T07:09:55.587Z","parse_source":"script-pdfplumber","map_coord":[52.110566,20.85944],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":9},"category_scores":{"environment":9},"has_zh":true},"methods":[{"_id":"6a5dc9c3f1c10c8ce825fdad","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH - w KCl, pH - w H2O","methodology_en":"pH - in KCl, pH - in H2O","parameters":[{"name":"Zakres","range":"2,00 − 10,00"}],"parameters_en":[{"name":"Range","range":"2,00 − 10,00"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w KCl, pH - w H2O\nZakres 2,00 − 10,00\nMetoda potencjometryczna","reference":"PN-ISO 10390:1997","norm_bases":["PN-ISO 10390:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH - w KCl, pH - w H2O\nZakres 2,00 − 10,00\nMetoda potencjometryczna PN-ISO 10390:1997 Gleba pH - w KCl, pH - w H2O\nZakres 2,00 − 10,00\nMetoda potencjometryczna PN-ISO 10390:1997","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH - in KCl, pH - in H2O Potentiometric method Range PN-ISO 10390:1997","parameters_zh":[{"name":"范围","range":"2,00 − 10,00"}],"search_zh":"土壤 pH － 于 KCl 中，pH － 于 H2O 中 电位法 范围 PN-ISO 10390:1997","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH － 于 KCl 中，pH － 于 H2O 中"},{"_id":"6a5dc9c3f1c10c8ce825fdae","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,01 – 4,00) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 4,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,01 – 4,00) %\nMetoda miareczkowa","reference":"PN-ISO 11261:2002","norm_bases":["PN-ISO 11261:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość azotu Kjeldahla\nZakres (0,01 – 4,00) %\nMetoda miareczkowa PN-ISO 11261:2002 Gleba Zawartosc azotu Kjeldahla\nZakres (0,01 – 4,00) %\nMetoda miareczkowa PN-ISO 11261:2002","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Kjeldahl nitrogen content Titrimetric method Range PN-ISO 11261:2002","parameters_zh":[{"name":"范围","range":"(0,01 – 4,00) %"}],"search_zh":"土壤 凯氏氮含量 滴定法 范围 PN-ISO 11261:2002","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"凯氏氮含量"},{"_id":"6a5dc9c3f1c10c8ce825fdaf","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość węgla ogólnego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,04 – 50,00) %"}],"parameters_en":[{"name":"Range","range":"(0,04 – 50,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla ogólnego\nZakres (0,04 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-ISO 10694:2002","norm_bases":["PN-ISO 10694:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość węgla ogólnego\nZakres (0,04 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-ISO 10694:2002 Gleba Zawartosc wegla ogolnego\nZakres (0,04 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-ISO 10694:2002","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Total carbon content High-temperature combustion with IR detection Range PN-ISO 10694:2002","parameters_zh":[{"name":"范围","range":"(0,04 – 50,00) %"}],"search_zh":"土壤 高温燃烧红外检测法 范围 PN-ISO 10694:2002","technique_zh":"高温燃烧红外检测法","test_object_zh":"土壤"},{"_id":"6a5dc9c3f1c10c8ce825fdb0","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość węgla ogólnego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,05 – 60,00) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 60,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TCD","techniques":["Metoda wysokotemperaturowego spalania z detekcją TCD"],"technique_en":"High-temperature combustion with TCD detection","computed":[],"computed_en":[],"activity":"Zawartość węgla ogólnego\nZakres (0,05 – 60,00) %\nMetoda wysokotemperaturowego spalania z detekcją TCD","reference":"PN-ISO 10694:2002","norm_bases":["PN-ISO 10694:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość węgla ogólnego\nZakres (0,05 – 60,00) %\nMetoda wysokotemperaturowego spalania z detekcją TCD PN-ISO 10694:2002 Gleba Zawartosc wegla ogolnego\nZakres (0,05 – 60,00) %\nMetoda wysokotemperaturowego spalania z detekcja TCD PN-ISO 10694:2002","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Total carbon content High-temperature combustion with TCD detection Range PN-ISO 10694:2002","parameters_zh":[{"name":"范围","range":"(0,05 – 60,00) %"}],"search_zh":"土壤 高温燃烧热导检测法（TCD） 范围 PN-ISO 10694:2002","test_object_zh":"土壤","technique_zh":"高温燃烧热导检测法（TCD）"},{"_id":"6a5dc9c3f1c10c8ce825fdb1","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość azotu całkowitego","methodology_en":"Total nitrogen content","parameters":[{"name":"Zakres","range":"(0,02 – 4,00) %"}],"parameters_en":[{"name":"Range","range":"(0,02 – 4,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TCD","techniques":["Metoda wysokotemperaturowego spalania z detekcją TCD"],"technique_en":"High-temperature combustion with TCD detection","computed":[],"computed_en":[],"activity":"Zawartość azotu całkowitego\nZakres (0,02 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcją TCD","reference":"PN-ISO 13878:2002","norm_bases":["PN-ISO 13878:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość azotu całkowitego\nZakres (0,02 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcją TCD PN-ISO 13878:2002 Gleba Zawartosc azotu calkowitego\nZakres (0,02 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcja TCD PN-ISO 13878:2002","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Total nitrogen content High-temperature combustion with TCD detection Range PN-ISO 13878:2002","parameters_zh":[{"name":"范围","range":"(0,02 – 4,00) %"}],"search_zh":"土壤 总氮含量 高温燃烧热导检测法（TCD） 范围 PN-ISO 13878:2002","test_object_zh":"土壤","technique_zh":"高温燃烧热导检测法（TCD）","methodology_zh":"总氮含量"},{"_id":"6a5dc9c3f1c10c8ce825fdb2","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Kwasowość hydrolityczna","methodology_en":"Hydrolytic acidity","parameters":[{"name":"Zakres","range":"(0,15 – 150,00) cmol/kg"}],"parameters_en":[{"name":"Range","range":"(0,15 – 150,00) cmol/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Kwasowość hydrolityczna\nZakres (0,15 – 150,00) cmol/kg\nMetoda miareczkowa","reference":"PN-R-04027:1997","norm_bases":["PN-R-04027:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Kwasowość hydrolityczna\nZakres (0,15 – 150,00) cmol/kg\nMetoda miareczkowa PN-R-04027:1997 Gleba Kwasowosc hydrolityczna\nZakres (0,15 – 150,00) cmol/kg\nMetoda miareczkowa PN-R-04027:1997","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Hydrolytic acidity Titrimetric method Range PN-R-04027:1997","parameters_zh":[{"name":"范围","range":"(0,15 – 150,00) cmol/kg"}],"search_zh":"土壤 水解酸度 滴定法 范围 PN-R-04027:1997","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"水解酸度"},{"_id":"6a5dc9c3f1c10c8ce825fdb3","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Kwasowość hydrolityczna","methodology_en":"Hydrolytic acidity","parameters":[{"name":"Zakres","range":"(0,15 – 150,00) cmol/kg"}],"parameters_en":[{"name":"Range","range":"(0,15 – 150,00) cmol/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Kwasowość hydrolityczna\nZakres (0,15 – 150,00) cmol/kg\nMetoda miareczkowa","reference":"PB-14 wydanie 5 z dnia 28.03.2024 r.","norm_bases":["PB-14 wydanie 5 z dnia 28.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Kwasowość hydrolityczna\nZakres (0,15 – 150,00) cmol/kg\nMetoda miareczkowa PB-14 wydanie 5 z dnia 28.03.2024 r. Gleba Kwasowosc hydrolityczna\nZakres (0,15 – 150,00) cmol/kg\nMetoda miareczkowa PB-14 wydanie 5 z dnia 28.03.2024 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Hydrolytic acidity Titrimetric method Range PB-14 wydanie 5 z dnia 28.03.2024 r.","parameters_zh":[{"name":"范围","range":"(0,15 – 150,00) cmol/kg"}],"search_zh":"土壤 水解酸度 滴定法 范围 PB-14 wydanie 5 z dnia 28.03.2024 r.","technique_zh":"滴定法","test_object_zh":"土壤","methodology_zh":"水解酸度"},{"_id":"6a5dc9c3f1c10c8ce825fdb4","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość kationów wymiennych:","methodology_en":"Exchangeable cation content:","parameters":[{"name":"Ca","range":"(0,0025 – 115,0000) cmol/kg"},{"name":"Mg","range":"(0,0015 – 12,0000) cmol/kg"},{"name":"K","range":"(0,0013 – 7,5000) cmol/kg"},{"name":"Na","range":"(0,0012 – 3,0000) cmol/kg"}],"parameters_en":[{"name":"Ca","range":"(0,0025 – 115,0000) cmol/kg"},{"name":"Mg","range":"(0,0015 – 12,0000) cmol/kg"},{"name":"K","range":"(0,0013 – 7,5000) cmol/kg"},{"name":"Na","range":"(0,0012 – 3,0000) cmol/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość kationów wymiennych:\nZakres:\nCa (0,0025 – 115,0000) cmol/kg\nMg (0,0015 – 12,0000) cmol/kg\nK (0,0013 – 7,5000) cmol/kg\nNa (0,0012 – 3,0000) cmol/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-03 wydanie 9 z dnia 28.03.2024 r.","norm_bases":["PB-03 wydanie 9 z dnia 28.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość kationów wymiennych:\nZakres:\nCa (0,0025 – 115,0000) cmol/kg\nMg (0,0015 – 12,0000) cmol/kg\nK (0,0013 – 7,5000) cmol/kg\nNa (0,0012 – 3,0000) cmol/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-03 wydanie 9 z dnia 28.03.2024 r. Gleba Zawartosc kationow wymiennych:\nZakres:\nCa (0,0025 – 115,0000) cmol/kg\nMg (0,0015 – 12,0000) cmol/kg\nK (0,0013 – 7,5000) cmol/kg\nNa (0,0012 – 3,0000) cmol/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-03 wydanie 9 z dnia 28.03.2024 r.","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Exchangeable cation content: Flame atomic absorption spectrometry (FAAS) Ca Mg K Na PB-03 wydanie 9 z dnia 28.03.2024 r.","search_zh":"土壤 火焰原子吸收光谱法（FAAS） Ca Mg K Na PB-03 wydanie 9 z dnia 28.03.2024 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"土壤","parameters_zh":[{"name":"Ca","range":"(0,0025 – 115,0000) cmol/kg"},{"name":"Mg","range":"(0,0015 – 12,0000) cmol/kg"},{"name":"K","range":"(0,0013 – 7,5000) cmol/kg"},{"name":"Na","range":"(0,0012 – 3,0000) cmol/kg"}]},{"_id":"6a5dc9c3f1c10c8ce825fdb5","lab_id":"69ad52a3de79e566650fb4c2","country":"PL","accr_number":"AB 945","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Skład granulometryczny frakcji < 2 mm, podział na piaski, pyły, iły, Procentowa zawartość","methodology_en":"Particle size distribution of the < 2 mm fraction, division into sands, silts, clays, Percentage content","parameters":[],"parameters_en":[],"technique":"Metoda areometryczno-sitowa","techniques":["Metoda areometryczno-sitowa"],"technique_en":"Hydrometer-sieve method","computed":[],"computed_en":[],"activity":"Skład granulometryczny frakcji < 2 mm, podział na piaski, pyły, iły, Procentowa zawartość\nMetoda areometryczno-sitowa","reference":"PN-R-04032:1998","norm_bases":["PN-R-04032:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Skład granulometryczny frakcji < 2 mm, podział na piaski, pyły, iły, Procentowa zawartość\nMetoda areometryczno-sitowa PN-R-04032:1998 Gleba Sklad granulometryczny frakcji < 2 mm, podzial na piaski, pyly, ily, Procentowa zawartosc\nMetoda areometryczno-sitowa PN-R-04032:1998","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Particle size distribution of the < 2 mm fraction, division into sands, silts, clays, Percentage content Hydrometer-sieve method PN-R-04032:1998","search_zh":"土壤 PN-R-04032:1998","test_object_zh":"土壤"}],"has_pdf":true}