{"lab":{"_id":"69ad52a3de79e566650fb4b2","accr_number":"AB 935","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ ŚRODOWISKA, ul. Sienkiewicza 4, 56-120 Brzeg Dolny","categories":["environment","water","materials"],"city":"Brzeg Dolny","imported_at":"2026-03-08T10:42:43.265Z","methods_count":219,"name":"LABANALITYKA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_935.pdf"],"scope_summary":"","search_text":"labanalityka sp. z o.o. laboratorium badań środowiska, ul. sienkiewicza 4, 56-120 brzeg dolny materials environment other petro pharma electronics metrology water food","status":"active","updated_at":"2026-03-08T14:51:49.930Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:49.930Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20935,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P, C/36/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków i gazów (gazy odlotowe)","en":"Chemical tests and sampling of water, drinking water, sewage, and gases (waste gases)"},{"codes":"C/32","pl":"Badania chemiczne odpadów","en":"Chemical tests of waste"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33; G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) –środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, mikroklimat, hałas), gazy (gazy odlotowe)","en":"Tests concerning environmental engineering (environmental and climatic) of workplace (harmful factors and nuisance – lighting, microclimate, noise), gases (waste gases)"},{"codes":"N/28/P, N/29/P, N/30/P, N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków i gazów (gazy odlotowe)","en":"Tests of physical properties and sampling of water, drinking water, sewage, and gases (waste gases)"},{"codes":"N/32","pl":"Badania właściwości fizycznych odpadów","en":"Tests of physical properties of waste"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling of- working environment (harmful factors - air)"}],"issue":{"no":"21","date":"04.09.2025"},"parse_date":"2026-07-20T07:09:55.172Z","parse_source":"script-pdfplumber","map_coord":[51.272114,16.730757],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":96,"other":73,"water":49,"materials":7,"petro":1},"category_scores":{"environment":40.78,"other":23.58,"water":10.62,"materials":0.22,"petro":0},"has_zh":true},"methods":[{"_id":"6a5dc9c3f1c10c8ce825fbe6","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie/zawartość krystalicznej krzemionki (kwarc i krystobalit) – frakcja respirabilna","methodology_en":"Concentration/content of crystalline silica (quartz and cristobalite) – respirable fraction","parameters":[{"name":"Zakres","range":"(0,01 – 0,7) mg/m3"},{"name":"Zakres","range":"(5 – 500) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,01 – 0,7) mg/m3"},{"name":"Range","range":"(5 – 500) μg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)"],"technique_en":"Fourier transform infrared spectrometry (FT-IR)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość krystalicznej krzemionki (kwarc i krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,01 – 0,7) mg/m3\nZakres (5 – 500) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny środowiska Pracy 2014, nr 3(81) s.103 - 119","norm_bases":["Podstawy i Metody Oceny środowiska Pracy 2014, nr 3(81) s.103 - 119"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie/zawartość krystalicznej krzemionki (kwarc i krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,01 – 0,7) mg/m3\nZakres (5 – 500) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny środowiska Pracy 2014, nr 3(81) s.103 - 119 Srodowisko pracy – powietrze Stezenie/zawartosc krystalicznej krzemionki (kwarc i krystobalit) – frakcja respirabilna\nZakres:\nZakres (0,01 – 0,7) mg/m3\nZakres (5 – 500) μg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny srodowiska Pracy 2014, nr 3(81) s.103 - 119","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Concentration/content of crystalline silica (quartz and cristobalite) – respirable fraction Fourier transform infrared spectrometry (FT-IR) Range Range Podstawy i Metody Oceny środowiska Pracy 2014, nr 3(81) s.103 - 119","parameters_zh":[{"name":"范围","range":"(0,01 – 0,7) mg/m3"},{"name":"范围","range":"(5 – 500) μg w próbce"}],"search_zh":"工作场所环境 — 空气 傅里叶变换红外光谱法（FT-IR） 范围 范围 Podstawy i Metody Oceny środowiska Pracy 2014, nr 3(81) s.103 - 119","test_object_zh":"工作场所环境 — 空气","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a5dc9c3f1c10c8ce825fbe7","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna – metale i ich związki – frakcja wdychalna – frakcja respirabilna"}],"parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – thoracic fraction – respirable fraction – metals and their compounds – inhalable fraction – respirable fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna – metale i ich związki – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna – metale i ich związki – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna – metale i ich zwiazki – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – thoracic fraction – respirable fraction – metals and their compounds – inhalable fraction – respirable fraction PN-Z-04008-7:2002 + Az1:2004","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"substancje nieorganiczne, w tym – frakcja torakalna – frakcja respirabilna – metale i ich związki – frakcja wdychalna – frakcja respirabilna"}]},{"_id":"6a5dc9c3f1c10c8ce825fbe8","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"substancje nieorganiczne"}],"parameters_en":[{"name":"inorganic substances"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"technique_en":"Stationary method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nsubstancje nieorganiczne\nMetoda stacjonarna PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Stationary method inorganic substances PN-Z-04008-7:2002 + Az1:2004","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点测定法 无机物质 PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"无机物质"}],"technique_zh":"定点测定法"},{"_id":"6a5dc9c3f1c10c8ce825fbe9","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9c3f1c10c8ce825fbea","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja","methodology_en":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja","parameters":[{"name":"wdychalna: – ditlenek tytanu – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – węgiel ( kamienny, brunatny)"},{"name":"Zakres","range":"(0,2 -17) mg/m3"}],"parameters_en":[{"name":"inhalable: – titanium dioxide – wood dust – flour dust – dusts not classified according to toxicity – coal ( hard, brown)"},{"name":"Range","range":"(0,2 -17) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja\nZakres:\nwdychalna: – ditlenek tytanu – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – węgiel ( kamienny, brunatny)\nZakres (0,2 -17) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08P","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08P"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja\nZakres:\nwdychalna: – ditlenek tytanu – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – węgiel ( kamienny, brunatny)\nZakres (0,2 -17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08P Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja\nZakres:\nwdychalna: – ditlenek tytanu – pyly drewna – pyly maki – pyly niesklasyfikowane ze wzgledu na toksycznosc – wegiel ( kamienny, brunatny)\nZakres (0,2 -17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08P","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja Gravimetric method inhalable: – titanium dioxide – wood dust – flour dust – dusts not classified according to toxicity – coal ( hard, brown) Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08P","parameters_zh":[{"name":"wdychalna: – ditlenek tytanu – pyły drewna – pyły mąki – pyły niesklasyfikowane ze względu na toksyczność – węgiel ( kamienny, brunatny)"},{"name":"范围","range":"(0,2 -17) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08P","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9c3f1c10c8ce825fbeb","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters":[{"name":"węgiel ( kamienny, brunatny)"},{"name":"Zakres","range":"(0,2-14) mg/m3"}],"parameters_en":[{"name":"coal ( hard, brown)"},{"name":"Range","range":"(0,2-14) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nwęgiel ( kamienny, brunatny)\nZakres (0,2-14) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08P","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08P"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nwęgiel ( kamienny, brunatny)\nZakres (0,2-14) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08P Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nwegiel ( kamienny, brunatny)\nZakres (0,2-14) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08P","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method coal ( hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08P","parameters_zh":[{"name":"węgiel ( kamienny, brunatny)"},{"name":"范围","range":"(0,2-14) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘： 重量法 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08P","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘："},{"_id":"6a5dc9c3f1c10c8ce825fbec","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","test_object_en":"Workplace environment – air","methodology":"Stężenie / zawartość chlorowodoru","methodology_en":"Hydrogen chloride concentration / content","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/m3"},{"name":"Zakres","range":"(0,2 – 4) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/m3"},{"name":"Range","range":"(0,2 – 4) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,5 – 10) mg/m3\nZakres (0,2 – 4) mg w próbce\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014","norm_bases":["PN-Z-04450:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,5 – 10) mg/m3\nZakres (0,2 – 4) mg w próbce\nMetoda turbidymetryczna PN-Z-04450:2014 Srodowisko pracy – powietrze Stezenie / zawartosc chlorowodoru\nZakres:\nZakres (0,5 – 10) mg/m3\nZakres (0,2 – 4) mg w probce\nMetoda turbidymetryczna PN-Z-04450:2014","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air Hydrogen chloride concentration / content Turbidimetric method Range Range PN-Z-04450:2014","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/m3"},{"name":"范围","range":"(0,2 – 4) mg w próbce"}],"search_zh":"工作场所环境 — 空气 氯化氢的浓度/含量 浊度法 范围 范围 PN-Z-04450:2014","test_object_zh":"工作场所环境 — 空气","technique_zh":"浊度法","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fbed","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość tlenków żelaza w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza – frakcja respirabilna","methodology_en":"Concentration / content of iron oxides expressed as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide – respirable fraction","parameters":[{"name":"Zakres","range":"(0,2 - 18) mg/m3"},{"name":"Zakres","range":"(0,1 - 13,8) mg w próbce"},{"name":"– frakcja wdychalna"},{"name":"Zakres","range":"(0,2 - 20) mg/m3"},{"name":"Zakres","range":"(0,1 - 13,8) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,2 - 18) mg/m3"},{"name":"Range","range":"(0,1 - 13,8) mg w próbce"},{"name":"– inhalable fraction"},{"name":"Range","range":"(0,2 - 20) mg/m3"},{"name":"Range","range":"(0,1 - 13,8) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość tlenków żelaza w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza – frakcja respirabilna\nZakres:\nZakres (0,2 - 18) mg/m3\nZakres (0,1 - 13,8) mg w próbce\n– frakcja wdychalna\nZakres (0,2 - 20) mg/m3\nZakres (0,1 - 13,8) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość tlenków żelaza w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza – frakcja respirabilna\nZakres:\nZakres (0,2 - 18) mg/m3\nZakres (0,1 - 13,8) mg w próbce\n– frakcja wdychalna\nZakres (0,2 - 20) mg/m3\nZakres (0,1 - 13,8) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc tlenkow zelaza w przeliczeniu na Fe Tlenek zelaza (III) Tlenek zelaza (II) Tetratlenek trizelaza – frakcja respirabilna\nZakres:\nZakres (0,2 - 18) mg/m3\nZakres (0,1 - 13,8) mg w probce\n– frakcja wdychalna\nZakres (0,2 - 20) mg/m3\nZakres (0,1 - 13,8) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of iron oxides expressed as Fe Iron (III) oxide Iron (II) oxide Triiron tetraoxide – respirable fraction Flame atomic absorption spectrometry (FAAS) Range Range – inhalable fraction Range Range PN-Z-04469:2025-02","parameters_zh":[{"name":"范围","range":"(0,2 - 18) mg/m3"},{"name":"范围","range":"(0,1 - 13,8) mg w próbce"},{"name":"– frakcja wdychalna"},{"name":"范围","range":"(0,2 - 20) mg/m3"},{"name":"范围","range":"(0,1 - 13,8) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 范围 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbee","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna – frakcja respirabilna","methodology_en":"Concentration / content of manganese and its inorganic compounds expressed as Mn – inhalable fraction – respirable fraction","parameters":[{"name":"Zakres","range":"(0,004 – 1,0) mg/m3"},{"name":"Zakres","range":"(0,003 - 0,7) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,004 – 1,0) mg/m3"},{"name":"Range","range":"(0,003 - 0,7) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna – frakcja respirabilna\nZakres:\nZakres (0,004 – 1,0) mg/m3\nZakres (0,003 - 0,7) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10","PN-Z-04472:2015-10/Ap1:2015-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna – frakcja respirabilna\nZakres:\nZakres (0,004 – 1,0) mg/m3\nZakres (0,003 - 0,7) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn – frakcja wdychalna – frakcja respirabilna\nZakres:\nZakres (0,004 – 1,0) mg/m3\nZakres (0,003 - 0,7) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of manganese and its inorganic compounds expressed as Mn – inhalable fraction – respirable fraction Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","parameters_zh":[{"name":"范围","range":"(0,004 – 1,0) mg/m3"},{"name":"范围","range":"(0,003 - 0,7) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04472:2015-10 | PN-Z-04472:2015-10/Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbef","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość benzenu","methodology_en":"Benzene concentration / content","parameters":[{"name":"Zakres","range":"(0,05 – 50) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"},{"name":"Zakres","range":"(0,02 – 15,4) ppm"}],"parameters_en":[{"name":"Range","range":"(0,05 – 50) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"},{"name":"Range","range":"(0,02 – 15,4) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość benzenu\nZakres:\nZakres (0,05 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,02 – 15,4) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość benzenu\nZakres:\nZakres (0,05 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,02 – 15,4) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc benzenu\nZakres:\nZakres (0,05 – 50) mg/m3\nZakres (0,001 – 1,0) mg w probce\nZakres (0,02 – 15,4) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Benzene concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,05 – 50) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"},{"name":"范围","range":"(0,02 – 15,4) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"苯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fbf0","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość toluenu","methodology_en":"Concentration / content of toluene","parameters":[{"name":"Zakres","range":"(0,25 – 200) mg/m3"},{"name":"Zakres","range":"(0,005 – 4,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,25 – 200) mg/m3"},{"name":"Range","range":"(0,005 – 4,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość toluenu\nZakres:\nZakres (0,25 – 200) mg/m3\nZakres (0,005 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1 (67) s. 35-44","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1 (67) s. 35-44"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość toluenu\nZakres:\nZakres (0,25 – 200) mg/m3\nZakres (0,005 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1 (67) s. 35-44 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc toluenu\nZakres:\nZakres (0,25 – 200) mg/m3\nZakres (0,005 – 4,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2011, nr 1 (67) s. 35-44","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of toluene Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1 (67) s. 35-44","parameters_zh":[{"name":"范围","range":"(0,25 – 200) mg/m3"},{"name":"范围","range":"(0,005 – 4,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2011, nr 1 (67) s. 35-44","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf1","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość epoksyetanu","methodology_en":"Concentration / content of epoxyethane","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"},{"name":"Zakres","range":"(0,05 – 54,7) ppm"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"},{"name":"Range","range":"(0,05 – 54,7) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość epoksyetanu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,05 – 54,7) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04300:2002","norm_bases":["PN-Z-04300:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość epoksyetanu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,05 – 54,7) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04300:2002 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc epoksyetanu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w probce\nZakres (0,05 – 54,7) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04300:2002","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of epoxyethane Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04300:2002","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"},{"name":"范围","range":"(0,05 – 54,7) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04300:2002","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf2","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość 1,2-epoksypropanu","methodology_en":"Concentration / content of 1,2-epoxypropane","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"},{"name":"Zakres","range":"(0,04 – 41,5) ppm"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"},{"name":"Range","range":"(0,04 – 41,5) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość 1,2-epoksypropanu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,04 – 41,5) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04286:2003","norm_bases":["PN-Z-04286:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość 1,2-epoksypropanu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,04 – 41,5) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04286:2003 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc 1,2-epoksypropanu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w probce\nZakres (0,04 – 41,5) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04286:2003","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of 1,2-epoxypropane Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04286:2003","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"},{"name":"范围","range":"(0,04 – 41,5) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04286:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf3","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość butanon-2-onu","methodology_en":"Concentration / content of butanon-2-one","parameters":[{"name":"Zakres","range":"(2,2 – 889) mg/m3"},{"name":"Zakres","range":"(0,01 – 4,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(2,2 – 889) mg/m3"},{"name":"Range","range":"(0,01 – 4,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość butanon-2-onu\nZakres:\nZakres (2,2 – 889) mg/m3\nZakres (0,01 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04449:2014-06","norm_bases":["PN-Z-04449:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość butanon-2-onu\nZakres:\nZakres (2,2 – 889) mg/m3\nZakres (0,01 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04449:2014-06 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc butanon-2-onu\nZakres:\nZakres (2,2 – 889) mg/m3\nZakres (0,01 – 4,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04449:2014-06","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of butanon-2-one Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04449:2014-06","parameters_zh":[{"name":"范围","range":"(2,2 – 889) mg/m3"},{"name":"范围","range":"(0,01 – 4,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04449:2014-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf4","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość acetonu","methodology_en":"Concentration / content of acetone","parameters":[{"name":"Zakres","range":"(0,5 – 800) mg/m3"},{"name":"Zakres","range":"(0,005 – 8,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,5 – 800) mg/m3"},{"name":"Range","range":"(0,005 – 8,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość acetonu\nZakres:\nZakres (0,5 – 800) mg/m3\nZakres (0,005 – 8,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04057-01:1979","norm_bases":["PN-Z-04057-01:1979"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość acetonu\nZakres:\nZakres (0,5 – 800) mg/m3\nZakres (0,005 – 8,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04057-01:1979 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc acetonu\nZakres:\nZakres (0,5 – 800) mg/m3\nZakres (0,005 – 8,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04057-01:1979","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of acetone Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04057-01:1979","parameters_zh":[{"name":"范围","range":"(0,5 – 800) mg/m3"},{"name":"范围","range":"(0,005 – 8,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04057-01:1979","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf5","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość etanolu","methodology_en":"Concentration / content of ethanol","parameters":[{"name":"Zakres","range":"(1 – 400) mg/m3"},{"name":"Zakres","range":"(0,01 – 4,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(1 – 400) mg/m3"},{"name":"Range","range":"(0,01 – 4,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość etanolu\nZakres:\nZakres (1 – 400) mg/m3\nZakres (0,01 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość etanolu\nZakres:\nZakres (1 – 400) mg/m3\nZakres (0,01 – 4,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04023-02:1989 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc etanolu\nZakres:\nZakres (1 – 400) mg/m3\nZakres (0,01 – 4,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04023-02:1989","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of ethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04023-02:1989","parameters_zh":[{"name":"范围","range":"(1 – 400) mg/m3"},{"name":"范围","range":"(0,01 – 4,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04023-02:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf6","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość octanu etylu","methodology_en":"Concentration / content of ethyl acetate","parameters":[{"name":"Zakres","range":"(1 – 1470) mg/m3"},{"name":"Zakres","range":"(0,01 – 15,0) mg w próbce"},{"name":"Zakres","range":"(0,27 – 402) ppm"}],"parameters_en":[{"name":"Range","range":"(1 – 1470) mg/m3"},{"name":"Range","range":"(0,01 – 15,0) mg w próbce"},{"name":"Range","range":"(0,27 – 402) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość octanu etylu\nZakres:\nZakres (1 – 1470) mg/m3\nZakres (0,01 – 15,0) mg w próbce\nZakres (0,27 – 402) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023-02","norm_bases":["PN-89/Z-04023-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość octanu etylu\nZakres:\nZakres (1 – 1470) mg/m3\nZakres (0,01 – 15,0) mg w próbce\nZakres (0,27 – 402) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023-02 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc octanu etylu\nZakres:\nZakres (1 – 1470) mg/m3\nZakres (0,01 – 15,0) mg w probce\nZakres (0,27 – 402) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023-02","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of ethyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-89/Z-04023-02","parameters_zh":[{"name":"范围","range":"(1 – 1470) mg/m3"},{"name":"范围","range":"(0,01 – 15,0) mg w próbce"},{"name":"范围","range":"(0,27 – 402) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-89/Z-04023-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf7","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość dimetyloaminy","methodology_en":"Concentration / content of dimethylamine","parameters":[{"name":"Zakres","range":"(0,11 – 15) mg/m3"},{"name":"Zakres","range":"(0,0033 – 0,50) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,11 – 15) mg/m3"},{"name":"Range","range":"(0,0033 – 0,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość dimetyloaminy\nZakres:\nZakres (0,11 – 15) mg/m3\nZakres (0,0033 – 0,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I46 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I46 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość dimetyloaminy\nZakres:\nZakres (0,11 – 15) mg/m3\nZakres (0,0033 – 0,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I46 wydanie 4 z 2016-10-03 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc dimetyloaminy\nZakres:\nZakres (0,11 – 15) mg/m3\nZakres (0,0033 – 0,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I46 wydanie 4 z 2016-10-03","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of dimethylamine Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I46 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,11 – 15) mg/m3"},{"name":"范围","range":"(0,0033 – 0,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I46 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbf8","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość akrylonitrylu","methodology_en":"Concentration / content of acrylonitrile","parameters":[{"name":"Zakres","range":"(0,04 – 42) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"},{"name":"Zakres","range":"(0,02 – 19,1) ppm"}],"parameters_en":[{"name":"Range","range":"(0,04 – 42) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"},{"name":"Range","range":"(0,02 – 19,1) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość akrylonitrylu\nZakres:\nZakres (0,04 – 42) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,02 – 19,1) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04556:2024-09","norm_bases":["PN-Z-04556:2024-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość akrylonitrylu\nZakres:\nZakres (0,04 – 42) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nZakres (0,02 – 19,1) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04556:2024-09 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc akrylonitrylu\nZakres:\nZakres (0,04 – 42) mg/m3\nZakres (0,001 – 1,0) mg w probce\nZakres (0,02 – 19,1) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04556:2024-09","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of acrylonitrile Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04556:2024-09","parameters_zh":[{"name":"范围","range":"(0,04 – 42) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"},{"name":"范围","range":"(0,02 – 19,1) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 丙烯腈的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04556:2024-09","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"丙烯腈的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fbf9","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość styrenu","methodology_en":"Styrene concentration / content","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość styrenu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-11:1994 | PN-Z-04152-02:1986","norm_bases":["PN-Z-04113-11:1994","PN-Z-04152-02:1986"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość styrenu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-11:1994 | PN-Z-04152-02:1986 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc styrenu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-11:1994 | PN-Z-04152-02:1986","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Styrene concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-11:1994 | PN-Z-04152-02:1986","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 苯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-11:1994 | PN-Z-04152-02:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"苯乙烯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fbfa","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość chlorobenzenu","methodology_en":"Chlorobenzene concentration / content","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość chlorobenzenu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005 | PN-Z-04022-3:2001","norm_bases":["PN-Z-04016-10:2005","PN-Z-04022-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość chlorobenzenu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 | PN-Z-04022-3:2001 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc chlorobenzenu\nZakres:\nZakres (0,1 – 100) mg/m3\nZakres (0,001 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005 | PN-Z-04022-3:2001","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Chlorobenzene concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005 | PN-Z-04022-3:2001","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 氯苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005 | PN-Z-04022-3:2001","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"氯苯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fbfb","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość fenolu","methodology_en":"Phenol concentration / content","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/m3"},{"name":"Zakres","range":"(0,01 – 1,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/m3"},{"name":"Range","range":"(0,01 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość fenolu\nZakres:\nZakres (0,2 – 20) mg/m3\nZakres (0,01 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 s. 91-95","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 s. 91-95"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość fenolu\nZakres:\nZakres (0,2 – 20) mg/m3\nZakres (0,01 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 s. 91-95 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc fenolu\nZakres:\nZakres (0,2 – 20) mg/m3\nZakres (0,01 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1999, nr 22 s. 91-95","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Phenol concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 s. 91-95","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/m3"},{"name":"范围","range":"(0,01 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 苯酚的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22 s. 91-95","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fbfc","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość 4-chlorofenolu","methodology_en":"Concentration / content of 4-chlorophenol","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/m3"},{"name":"Zakres","range":"(0,01 – 1,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/m3"},{"name":"Range","range":"(0,01 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość 4-chlorofenolu\nZakres:\nZakres (0,2 – 20) mg/m3\nZakres (0,01 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I35 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość 4-chlorofenolu\nZakres:\nZakres (0,2 – 20) mg/m3\nZakres (0,01 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc 4-chlorofenolu\nZakres:\nZakres (0,2 – 20) mg/m3\nZakres (0,01 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I35 wydanie 4 z 2016-10-03","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of 4-chlorophenol Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/m3"},{"name":"范围","range":"(0,01 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbfd","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość 4-chlorofenolu","methodology_en":"Concentration / content of 4-chlorophenol","parameters":[{"name":"Zakres","range":"(0,025 – 1,54) mg/m3"},{"name":"Zakres","range":"(1,0 – 62) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,025 – 1,54) mg/m3"},{"name":"Range","range":"(1,0 – 62) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość 4-chlorofenolu\nZakres:\nZakres (0,025 – 1,54) mg/m3\nZakres (1,0 – 62) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PN-Z-04052-4:2010","norm_bases":["PN-Z-04052-4:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość 4-chlorofenolu\nZakres:\nZakres (0,025 – 1,54) mg/m3\nZakres (1,0 – 62) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PN-Z-04052-4:2010 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc 4-chlorofenolu\nZakres:\nZakres (0,025 – 1,54) mg/m3\nZakres (1,0 – 62) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PN-Z-04052-4:2010","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of 4-chlorophenol High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range PN-Z-04052-4:2010","parameters_zh":[{"name":"范围","range":"(0,025 – 1,54) mg/m3"},{"name":"范围","range":"(1,0 – 62) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 PN-Z-04052-4:2010","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbfe","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość izopropyloaminy","methodology_en":"Concentration / content of isopropylamine","parameters":[{"name":"Zakres","range":"(1,2 – 24) mg/m3"},{"name":"Zakres","range":"(0,06 – 1,2) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(1,2 – 24) mg/m3"},{"name":"Range","range":"(0,06 – 1,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość izopropyloaminy\nZakres:\nZakres (1,2 – 24) mg/m3\nZakres (0,06 – 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 74-78","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 74-78"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość izopropyloaminy\nZakres:\nZakres (1,2 – 24) mg/m3\nZakres (0,06 – 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 74-78 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc izopropyloaminy\nZakres:\nZakres (1,2 – 24) mg/m3\nZakres (0,06 – 1,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1997, nr 17 s. 74-78","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of isopropylamine Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 74-78","parameters_zh":[{"name":"范围","range":"(1,2 – 24) mg/m3"},{"name":"范围","range":"(0,06 – 1,2) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 74-78","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fbff","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość glikolu etylenowego","methodology_en":"Concentration / content of ethylene glycol","parameters":[{"name":"Zakres","range":"(1,25 – 80) mg/m3"},{"name":"Zakres","range":"(0,025 – 1,6) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(1,25 – 80) mg/m3"},{"name":"Range","range":"(0,025 – 1,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość glikolu etylenowego\nZakres:\nZakres (1,25 – 80) mg/m3\nZakres (0,025 – 1,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 55-59","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 55-59"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość glikolu etylenowego\nZakres:\nZakres (1,25 – 80) mg/m3\nZakres (0,025 – 1,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 55-59 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc glikolu etylenowego\nZakres:\nZakres (1,25 – 80) mg/m3\nZakres (0,025 – 1,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1997, nr 17 s. 55-59","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of ethylene glycol Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 55-59","parameters_zh":[{"name":"范围","range":"(1,25 – 80) mg/m3"},{"name":"范围","range":"(0,025 – 1,6) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 s. 55-59","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc00","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość glifosatu","methodology_en":"Concentration / content of glyphosate","parameters":[{"name":"Zakres","range":"(0,1 – 20) mg/m3"},{"name":"Zakres","range":"(0,1 – 20) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,1 – 20) mg/m3"},{"name":"Range","range":"(0,1 – 20) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość glifosatu\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,1 – 20) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2008, nr 1 (55) s. 35-40","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2008, nr 1 (55) s. 35-40"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość glifosatu\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,1 – 20) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Podstawy i Metody Oceny Środowiska Pracy 2008, nr 1 (55) s. 35-40 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc glifosatu\nZakres:\nZakres (0,1 – 20) mg/m3\nZakres (0,1 – 20) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Podstawy i Metody Oceny Srodowiska Pracy 2008, nr 1 (55) s. 35-40","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of glyphosate High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range Podstawy i Metody Oceny Środowiska Pracy 2008, nr 1 (55) s. 35-40","parameters_zh":[{"name":"范围","range":"(0,1 – 20) mg/m3"},{"name":"范围","range":"(0,1 – 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2008, nr 1 (55) s. 35-40","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc01","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość rtęci i jej par","methodology_en":"Concentration / content of mercury and its vapours","parameters":[{"name":"Zakres","range":"(0,00125 – 0,6) mg/m3"},{"name":"Zakres","range":"(0,05 – 24) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,00125 – 0,6) mg/m3"},{"name":"Range","range":"(0,05 – 24) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość rtęci i jej par\nZakres:\nZakres (0,00125 – 0,6) mg/m3\nZakres (0,05 – 24) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-Z-04332:2006","norm_bases":["PN-Z-04332:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość rtęci i jej par\nZakres:\nZakres (0,00125 – 0,6) mg/m3\nZakres (0,05 – 24) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-Z-04332:2006 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc rteci i jej par\nZakres:\nZakres (0,00125 – 0,6) mg/m3\nZakres (0,05 – 24) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-Z-04332:2006","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of mercury and its vapours Cold vapour atomic absorption spectrometry (CVAAS) Range Range PN-Z-04332:2006","parameters_zh":[{"name":"范围","range":"(0,00125 – 0,6) mg/m3"},{"name":"范围","range":"(0,05 – 24) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 冷蒸气原子吸收光谱法（CVAAS） 范围 范围 PN-Z-04332:2006","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc02","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość diiizocyjanianu metylenodifenylu – mieszanina izomerów (MDI)","methodology_en":"Concentration / content of methylenediphenyl diisocyanate – mixture of isomers (MDI)","parameters":[{"name":"Zakres","range":"(0,0006 – 0,054) mg/m3"},{"name":"Zakres","range":"(0,043 – 6,5) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0006 – 0,054) mg/m3"},{"name":"Range","range":"(0,043 – 6,5) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość diiizocyjanianu metylenodifenylu – mieszanina izomerów (MDI)\nZakres:\nZakres (0,0006 – 0,054) mg/m3\nZakres (0,043 – 6,5) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","norm_bases":["PRB.ŚPP.8I87 wydanie 2 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość diiizocyjanianu metylenodifenylu – mieszanina izomerów (MDI)\nZakres:\nZakres (0,0006 – 0,054) mg/m3\nZakres (0,043 – 6,5) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PRB.ŚPP.8I87 wydanie 2 z 2016-10-03 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc diiizocyjanianu metylenodifenylu – mieszanina izomerow (MDI)\nZakres:\nZakres (0,0006 – 0,054) mg/m3\nZakres (0,043 – 6,5) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PRB.SPP.8I87 wydanie 2 z 2016-10-03","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of methylenediphenyl diisocyanate – mixture of isomers (MDI) High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,0006 – 0,054) mg/m3"},{"name":"范围","range":"(0,043 – 6,5) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc03","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość diiizocyjanianu tolueno-2,4-diylu – (2,4-TDI)","methodology_en":"Concentration / content of toluene-2,4-diyl diisocyanate – (2,4-TDI)","parameters":[{"name":"Zakres","range":"(0,0005 – 0,04) mg/m3"},{"name":"Zakres","range":"(0,035 – 5,2) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0005 – 0,04) mg/m3"},{"name":"Range","range":"(0,035 – 5,2) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość diiizocyjanianu tolueno-2,4-diylu – (2,4-TDI)\nZakres:\nZakres (0,0005 – 0,04) mg/m3\nZakres (0,035 – 5,2) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","norm_bases":["PRB.ŚPP.8I87 wydanie 2 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość diiizocyjanianu tolueno-2,4-diylu – (2,4-TDI)\nZakres:\nZakres (0,0005 – 0,04) mg/m3\nZakres (0,035 – 5,2) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PRB.ŚPP.8I87 wydanie 2 z 2016-10-03 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc diiizocyjanianu tolueno-2,4-diylu – (2,4-TDI)\nZakres:\nZakres (0,0005 – 0,04) mg/m3\nZakres (0,035 – 5,2) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PRB.SPP.8I87 wydanie 2 z 2016-10-03","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of toluene-2,4-diyl diisocyanate – (2,4-TDI) High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,04) mg/m3"},{"name":"范围","range":"(0,035 – 5,2) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc04","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość diiizocyjanianu tolueno-2,6-diylu– (2,6-TDI)","methodology_en":"Concentration / content of toluene-2,6-diyl diisocyanate– (2,6-TDI)","parameters":[{"name":"Zakres","range":"(0,0005 – 0,04) mg/m3"},{"name":"Zakres","range":"(0,035 – 5,2) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0005 – 0,04) mg/m3"},{"name":"Range","range":"(0,035 – 5,2) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość diiizocyjanianu tolueno-2,6-diylu– (2,6-TDI)\nZakres:\nZakres (0,0005 – 0,04) mg/m3\nZakres (0,035 – 5,2) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","norm_bases":["PRB.ŚPP.8I87 wydanie 2 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość diiizocyjanianu tolueno-2,6-diylu– (2,6-TDI)\nZakres:\nZakres (0,0005 – 0,04) mg/m3\nZakres (0,035 – 5,2) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) PRB.ŚPP.8I87 wydanie 2 z 2016-10-03 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc diiizocyjanianu tolueno-2,6-diylu– (2,6-TDI)\nZakres:\nZakres (0,0005 – 0,04) mg/m3\nZakres (0,035 – 5,2) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) PRB.SPP.8I87 wydanie 2 z 2016-10-03","categories":["environment"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of toluene-2,6-diyl diisocyanate– (2,6-TDI) High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,0005 – 0,04) mg/m3"},{"name":"范围","range":"(0,035 – 5,2) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 PRB.ŚPP.8I87 wydanie 2 z 2016-10-03","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc05","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość kwasu octowego","methodology_en":"Concentration / content of acetic acid","parameters":[{"name":"Zakres","range":"(0,02 – 64) mg/m3"},{"name":"Zakres","range":"(0,001 – 3,2) mg w próbce"},{"name":"Zakres","range":"(0,01 – 25,7) ppm"}],"parameters_en":[{"name":"Range","range":"(0,02 – 64) mg/m3"},{"name":"Range","range":"(0,001 – 3,2) mg w próbce"},{"name":"Range","range":"(0,01 – 25,7) ppm"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość kwasu octowego\nZakres:\nZakres (0,02 – 64) mg/m3\nZakres (0,001 – 3,2) mg w próbce\nZakres (0,01 – 25,7) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość kwasu octowego\nZakres:\nZakres (0,02 – 64) mg/m3\nZakres (0,001 – 3,2) mg w próbce\nZakres (0,01 – 25,7) ppm\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04323:2004 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc kwasu octowego\nZakres:\nZakres (0,02 – 64) mg/m3\nZakres (0,001 – 3,2) mg w probce\nZakres (0,01 – 25,7) ppm\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04323:2004","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of acetic acid Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04323:2004","parameters_zh":[{"name":"范围","range":"(0,02 – 64) mg/m3"},{"name":"范围","range":"(0,001 – 3,2) mg w próbce"},{"name":"范围","range":"(0,01 – 25,7) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04323:2004","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc06","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość pentanu","methodology_en":"Pentane concentration / content","parameters":[{"name":"Zakres","range":"(4-– 500) mg/m3"},{"name":"Zakres","range":"(0,008 – 1,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(4-– 500) mg/m3"},{"name":"Range","range":"(0,008 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość pentanu\nZakres:\nZakres (4-– 500) mg/m3\nZakres (0,008 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość pentanu\nZakres:\nZakres (4-– 500) mg/m3\nZakres (0,008 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc pentanu\nZakres:\nZakres (4-– 500) mg/m3\nZakres (0,008 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["environment"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Pentane concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(4-– 500) mg/m3"},{"name":"范围","range":"(0,008 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 戊烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"戊烷的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc07","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość amoniaku","methodology_en":"Ammonia concentration / content","parameters":[{"name":"Zakres","range":"(0,5 – 40) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,02) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,5 – 40) mg/m3"},{"name":"Range","range":"(0,001 – 0,02) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość amoniaku\nZakres:\nZakres (0,5 – 40) mg/m3\nZakres (0,001 – 0,02) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-3:1990","norm_bases":["PN-Z-04009-3:1990"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość amoniaku\nZakres:\nZakres (0,5 – 40) mg/m3\nZakres (0,001 – 0,02) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-3:1990 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc amoniaku\nZakres:\nZakres (0,5 – 40) mg/m3\nZakres (0,001 – 0,02) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-3:1990","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Ammonia concentration / content Spectrophotometric method Range Range PN-Z-04009-3:1990","parameters_zh":[{"name":"范围","range":"(0,5 – 40) mg/m3"},{"name":"范围","range":"(0,001 – 0,02) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 氨的浓度/含量 分光光度法 范围 范围 PN-Z-04009-3:1990","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"氨的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc08","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość kwasu siarkowego (VI) – frakcja torakalna","methodology_en":"Concentration / content of sulphuric (VI) acid – thoracic fraction","parameters":[{"name":"Zakres","range":"(0,002 – 0,09) mg/m3"},{"name":"Zakres","range":"(1 –41) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,002 – 0,09) mg/m3"},{"name":"Range","range":"(1 –41) μg w próbce"}],"technique":"Metoda chromatografii jonowej detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość kwasu siarkowego (VI) – frakcja torakalna\nZakres:\nZakres (0,002 – 0,09) mg/m3\nZakres (1 –41) μg w próbce\nMetoda chromatografii jonowej detekcją konduktometryczną (IC-CD)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5-19","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5-19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość kwasu siarkowego (VI) – frakcja torakalna\nZakres:\nZakres (0,002 – 0,09) mg/m3\nZakres (1 –41) μg w próbce\nMetoda chromatografii jonowej detekcją konduktometryczną (IC-CD) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5-19 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc kwasu siarkowego (VI) – frakcja torakalna\nZakres:\nZakres (0,002 – 0,09) mg/m3\nZakres (1 –41) μg w probce\nMetoda chromatografii jonowej detekcja konduktometryczna (IC-CD) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 5-19","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of sulphuric (VI) acid – thoracic fraction Ion chromatography with conductometric detection (IC-CD) Range Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5-19","parameters_zh":[{"name":"范围","range":"(0,002 – 0,09) mg/m3"},{"name":"范围","range":"(1 –41) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 硫酸(VI)的浓度/含量 － 胸腔性粉尘 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5-19","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"硫酸(VI)的浓度/含量 － 胸腔性粉尘"},{"_id":"6a5dc9c3f1c10c8ce825fc09","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość chloru","methodology_en":"Chlorine concentration / content","parameters":[{"name":"Zakres","range":"(0,05 – 2,5) mg/m3"},{"name":"Zakres","range":"(0,25 – 10) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,5) mg/m3"},{"name":"Range","range":"(0,25 – 10) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość chloru\nZakres:\nZakres (0,05 – 2,5) mg/m3\nZakres (0,25 – 10) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04037-03:1975","norm_bases":["PN-Z-04037-03:1975"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość chloru\nZakres:\nZakres (0,05 – 2,5) mg/m3\nZakres (0,25 – 10) μg w próbce\nMetoda spektrofotometryczna PN-Z-04037-03:1975 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc chloru\nZakres:\nZakres (0,05 – 2,5) mg/m3\nZakres (0,25 – 10) μg w probce\nMetoda spektrofotometryczna PN-Z-04037-03:1975","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Chlorine concentration / content Spectrophotometric method Range Range PN-Z-04037-03:1975","parameters_zh":[{"name":"范围","range":"(0,05 – 2,5) mg/m3"},{"name":"范围","range":"(0,25 – 10) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 氯的浓度/含量 分光光度法 范围 范围 PN-Z-04037-03:1975","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"氯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc0a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,3 – 232) mg/m3"},{"name":"Zakres","range":"(2 – 200) ppm"}],"parameters_en":[{"name":"Range","range":"(2,3 – 232) mg/m3"},{"name":"Range","range":"(2 – 200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna","reference":"PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r","norm_bases":["PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r Srodowisko pracy – powietrze – probki powietrza Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna PRB.SPP.8I80 wydanie 4 z dnia 28.04.2025 r","categories":["environment"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Carbon monoxide concentration Electrochemical method Range Range PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r","parameters_zh":[{"name":"范围","range":"(2,3 – 232) mg/m3"},{"name":"范围","range":"(2 – 200) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 一氧化碳浓度 电化学法 范围 范围 PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"一氧化碳浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc0b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r","norm_bases":["PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Wskaźnik narażenia (z obliczeń) PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r Srodowisko pracy – powietrze – probki powietrza Wskaznik narazenia (z obliczen) PRB.SPP.8I80 wydanie 4 z dnia 28.04.2025 r","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Exposure index (calculated) PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 — 空气样品 暴露指数（计算得出） PRB.ŚPP.8I80 wydanie 4 z dnia 28.04.2025 r","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc0c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość ditlenku azotu","methodology_en":"Nitrogen dioxide concentration / content","parameters":[{"name":"Zakres","range":"(0,07 – 3,6) mg/m3"},{"name":"Zakres","range":"(0,3 – 16) μg w próbce"},{"name":"Zakres","range":"(0,04 – 1,9) ppm"}],"parameters_en":[{"name":"Range","range":"(0,07 – 3,6) mg/m3"},{"name":"Range","range":"(0,3 – 16) μg w próbce"},{"name":"Range","range":"(0,04 – 1,9) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 3,6) mg/m3\nZakres (0,3 – 16) μg w próbce\nZakres (0,04 – 1,9) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość ditlenku azotu\nZakres:\nZakres (0,07 – 3,6) mg/m3\nZakres (0,3 – 16) μg w próbce\nZakres (0,04 – 1,9) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc ditlenku azotu\nZakres:\nZakres (0,07 – 3,6) mg/m3\nZakres (0,3 – 16) μg w probce\nZakres (0,04 – 1,9) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Nitrogen dioxide concentration / content Spectrophotometric method Range Range Range PN-Z-04009-11:2008","parameters_zh":[{"name":"范围","range":"(0,07 – 3,6) mg/m3"},{"name":"范围","range":"(0,3 – 16) μg w próbce"},{"name":"范围","range":"(0,04 – 1,9) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 二氧化氮的浓度/含量 分光光度法 范围 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"二氧化氮的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc0d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość tlenku azotu","methodology_en":"Nitrogen oxide concentration / content","parameters":[{"name":"Zakres","range":"(0,2 – 11,5) mg/m3"},{"name":"Zakres","range":"(1 – 52) μg w próbce"},{"name":"Zakres","range":"(0,2 – 9,3) ppm"}],"parameters_en":[{"name":"Range","range":"(0,2 – 11,5) mg/m3"},{"name":"Range","range":"(1 – 52) μg w próbce"},{"name":"Range","range":"(0,2 – 9,3) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość tlenku azotu\nZakres:\nZakres (0,2 – 11,5) mg/m3\nZakres (1 – 52) μg w próbce\nZakres (0,2 – 9,3) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość tlenku azotu\nZakres:\nZakres (0,2 – 11,5) mg/m3\nZakres (1 – 52) μg w próbce\nZakres (0,2 – 9,3) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc tlenku azotu\nZakres:\nZakres (0,2 – 11,5) mg/m3\nZakres (1 – 52) μg w probce\nZakres (0,2 – 9,3) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Nitrogen oxide concentration / content Spectrophotometric method Range Range Range PN-Z-04009-11:2008","parameters_zh":[{"name":"范围","range":"(0,2 – 11,5) mg/m3"},{"name":"范围","range":"(1 – 52) μg w próbce"},{"name":"范围","range":"(0,2 – 9,3) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 一氧化氮的浓度/含量 分光光度法 范围 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"一氧化氮的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc0e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość kwasu chlorooctowego","methodology_en":"Concentration / content of chloroacetic acid","parameters":[{"name":"Zakres","range":"(0,2 – 4,0) mg/m3"},{"name":"Zakres","range":"(0,01 – 0,20) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,2 – 4,0) mg/m3"},{"name":"Range","range":"(0,01 – 0,20) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość kwasu chlorooctowego\nZakres:\nZakres (0,2 – 4,0) mg/m3\nZakres (0,01 – 0,20) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04215-03:1991","norm_bases":["PN-Z-04215-03:1991"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość kwasu chlorooctowego\nZakres:\nZakres (0,2 – 4,0) mg/m3\nZakres (0,01 – 0,20) mg w próbce\nMetoda spektrofotometryczna PN-Z-04215-03:1991 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc kwasu chlorooctowego\nZakres:\nZakres (0,2 – 4,0) mg/m3\nZakres (0,01 – 0,20) mg w probce\nMetoda spektrofotometryczna PN-Z-04215-03:1991","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of chloroacetic acid Spectrophotometric method Range Range PN-Z-04215-03:1991","parameters_zh":[{"name":"范围","range":"(0,2 – 4,0) mg/m3"},{"name":"范围","range":"(0,01 – 0,20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 分光光度法 范围 范围 PN-Z-04215-03:1991","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc0f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość 1,2-dichloropropanu","methodology_en":"Concentration / content of 1,2-dichloropropane","parameters":[{"name":"Zakres","range":"(0,1-100) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,1-100) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość 1,2-dichloropropanu\nZakres:\nZakres (0,1-100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, z.17 s.36-40","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, z.17 s.36-40"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość 1,2-dichloropropanu\nZakres:\nZakres (0,1-100) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1997, z.17 s.36-40 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc 1,2-dichloropropanu\nZakres:\nZakres (0,1-100) mg/m3\nZakres (0,001 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1997, z.17 s.36-40","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Concentration / content of 1,2-dichloropropane Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, z.17 s.36-40","parameters_zh":[{"name":"范围","range":"(0,1-100) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, z.17 s.36-40","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a5dc9c3f1c10c8ce825fc10","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość naftalenu","methodology_en":"Naphthalene concentration / content","parameters":[{"name":"Zakres","range":"(2,5 – 160) mg/m3"},{"name":"Zakres","range":"(0,05 – 3,2) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(2,5 – 160) mg/m3"},{"name":"Range","range":"(0,05 – 3,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość naftalenu\nZakres:\nZakres (2,5 – 160) mg/m3\nZakres (0,05 – 3,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04098-3:2005","norm_bases":["PN-Z-04098-3:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość naftalenu\nZakres:\nZakres (2,5 – 160) mg/m3\nZakres (0,05 – 3,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04098-3:2005 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc naftalenu\nZakres:\nZakres (2,5 – 160) mg/m3\nZakres (0,05 – 3,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04098-3:2005","categories":["environment"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Naphthalene concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04098-3:2005","parameters_zh":[{"name":"范围","range":"(2,5 – 160) mg/m3"},{"name":"范围","range":"(0,05 – 3,2) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 萘的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04098-3:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"萘的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc11","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","test_object_en":"Workplace environment – air – air samples","methodology":"Stężenie / zawartość formaldehydu","methodology_en":"Formaldehyde concentration / content","parameters":[{"name":"Zakres","range":"(0,021 – 1,66) mg/m3"},{"name":"Zakres","range":"(0,1 – 8,28) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,021 – 1,66) mg/m3"},{"name":"Range","range":"(0,1 – 8,28) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","computed":[],"computed_en":[],"activity":"Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,021 – 1,66) mg/m3\nZakres (0,1 – 8,28) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, z.22 s. 96-100","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, z.22 s. 96-100"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,021 – 1,66) mg/m3\nZakres (0,1 – 8,28) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) Podstawy i Metody Oceny Środowiska Pracy 1999, z.22 s. 96-100 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc formaldehydu\nZakres:\nZakres (0,021 – 1,66) mg/m3\nZakres (0,1 – 8,28) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) Podstawy i Metody Oceny Srodowiska Pracy 1999, z.22 s. 96-100","categories":["environment"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – air – air samples Formaldehyde concentration / content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range Podstawy i Metody Oceny Środowiska Pracy 1999, z.22 s. 96-100","parameters_zh":[{"name":"范围","range":"(0,021 – 1,66) mg/m3"},{"name":"范围","range":"(0,1 – 8,28) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 甲醛的浓度/含量 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, z.22 s. 96-100","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"甲醛的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc12","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(30 – 135) dB"},{"name":"Maksymalny poziom dźwięku A"},{"name":"Zakres","range":"(30 – 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 – 140) dB"}],"parameters_en":[{"name":"Range","range":"(30 – 135) dB"},{"name":"Maximum A-weighted sound pressure level"},{"name":"Range","range":"(30 – 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nMaksymalny poziom dźwięku A\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A\nZakres:\nZakres (30 – 135) dB\nMaksymalny poziom dźwięku A\nZakres (30 – 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A\nZakres:\nZakres (30 – 135) dB\nMaksymalny poziom dzwieku A\nZakres (30 – 135) dB\nSzczytowy poziom dzwieku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 - punkt 10 i 3 - punkt 11","categories":["environment"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – noise A-weighted equivalent sound pressure level Direct measurement method Range Maximum A-weighted sound pressure level Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30 – 135) dB"},{"name":"A 计权最大声级"},{"name":"范围","range":"(30 – 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 – 140) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 直接测量法 范围 A 计权最大声级 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9c3f1c10c8ce825fc13","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – hałas","test_object_en":"Workplace environment – noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 - punkt 10 i 3 - punkt 11","categories":["environment"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i 3 - punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9c3f1c10c8ce825fc14","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(5 – 5000) lx"}],"parameters_en":[{"name":"Range","range":"(5 – 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-E-04040-03:1983","norm_bases":["PN-E-04040-03:1983"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia PN-E-04040-03:1983 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezposrednia PN-E-04040-03:1983","categories":["environment"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Range PN-E-04040-03:1983","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-E-04040-03:1983","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9c3f1c10c8ce825fc15","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment – indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-E-04040-03:1983","norm_bases":["PN-E-04040-03:1983"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-E-04040-03:1983 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-E-04040-03:1983","categories":["environment"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-E-04040-03:1983","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-E-04040-03:1983","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9c3f1c10c8ce825fc16","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 40) °C"}],"parameters_en":[{"name":"Range","range":"(10 – 40) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 40) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 40) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 40) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 40) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 40) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 40) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9c3f1c10c8ce825fc17","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Wskaźnik WBGT, WBGTeff (z obliczeń)","methodology_en":"WBGT, WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – hot microclimate WBGT, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（由计算得出） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候","methodology_zh":"WBGT 指数、WBGTeff 指数（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc18","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(0 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(0 – 35) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,2 – 1,0) m/s"}],"parameters_en":[{"name":"Range","range":"(0 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(0 – 35) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,2 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (0 – 30) °C\nTemperatura poczernionej kuli\nZakres (0 – 35) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,2 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (0 – 30) °C\nTemperatura poczernionej kuli\nZakres (0 – 35) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,2 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (0 – 30) °C\nTemperatura poczernionej kuli\nZakres (0 – 35) °C\nWilgotnosc powietrza\nZakres (25 – 75) %\nPredkosc powietrza\nZakres (0,2 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(0 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(0 – 35) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,2 – 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9c3f1c10c8ce825fc19","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index, PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006","categories":["environment"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9c3f1c10c8ce825fc1a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9c3f1c10c8ce825fc1b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c3f1c10c8ce825fc1c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(3 – 150) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(3 – 150) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (3 – 150) mg/l Pt\nMetoda spektrofotometryczna","reference":"PRB.SPP.8I49 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8025 01/2014 E9","norm_bases":["PRB.SPP.8I49 Wydanie 7 z 20.03.2024","na podstawie aplikacji HACH Lange Metoda 8025 01/2014 E9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (3 – 150) mg/l Pt\nMetoda spektrofotometryczna PRB.SPP.8I49 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8025 01/2014 E9 Woda do spozycia przez ludzi Barwa\nZakres (3 – 150) mg/l Pt\nMetoda spektrofotometryczna PRB.SPP.8I49 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8025 01/2014 E9","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Spectrophotometric method Range PRB.SPP.8I49 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8025 01/2014 E9","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3 – 150) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PRB.SPP.8I49 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8025 01/2014 E9","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c3f1c10c8ce825fc1d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(3 – 250) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(3 – 250) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (3 – 250) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C","norm_bases":["PN-EN ISO 7887:2012 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (3 – 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (3 – 250) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3 – 250) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c3f1c10c8ce825fc1e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,1 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,1 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,1 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,1 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,1 – 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c3f1c10c8ce825fc1f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,02 – 3,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,02 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PRB.ŚPP.8I63 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8008 07/2005 E1","norm_bases":["PRB.ŚPP.8I63 Wydanie 7 z 20.03.2024","na podstawie aplikacji HACH Lange Metoda 8008 07/2005 E1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,02 – 3,00) mg/l\nMetoda spektrofotometryczna PRB.ŚPP.8I63 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8008 07/2005 E1 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,02 – 3,00) mg/l\nMetoda spektrofotometryczna PRB.SPP.8I63 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8008 07/2005 E1","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Range PRB.ŚPP.8I63 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8008 07/2005 E1","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 3,00) mg/l"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 范围 PRB.ŚPP.8I63 Wydanie 7 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8008 07/2005 E1","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c3f1c10c8ce825fc20","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,006– 0,700) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,006– 0,700) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,006– 0,700) mg/l\nMetoda spektrofotometryczna","reference":"PRB.ŚPP.8I51 wydanie 6 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8149 07/2005 E1","norm_bases":["PRB.ŚPP.8I51 wydanie 6 z 20.03.2024","na podstawie aplikacji HACH Lange Metoda 8149 07/2005 E1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,006– 0,700) mg/l\nMetoda spektrofotometryczna PRB.ŚPP.8I51 wydanie 6 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8149 07/2005 E1 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,006– 0,700) mg/l\nMetoda spektrofotometryczna PRB.SPP.8I51 wydanie 6 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8149 07/2005 E1","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PRB.ŚPP.8I51 wydanie 6 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8149 07/2005 E1","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,006– 0,700) mg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PRB.ŚPP.8I51 wydanie 6 z 20.03.2024 | na podstawie aplikacji HACH Lange Metoda 8149 07/2005 E1","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c3f1c10c8ce825fc21","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"fluorki","range":"(0,4 – 10) mg/l"},{"name":"chlorki","range":"(0,4 – 10) mg/l"},{"name":"azotyny","range":"(0,4 – 10) mg/l"},{"name":"bromki","range":"(0,4 – 10) mg/l"},{"name":"azotany","range":"(0,4 – 10) mg/l"},{"name":"ortofosforany","range":"(0,4 – 10) mg/l"},{"name":"siarczany","range":"(0,5 – 10) mg/l"}],"parameters_en":[{"name":"fluorides","range":"(0,4 – 10) mg/l"},{"name":"chlorides","range":"(0,4 – 10) mg/l"},{"name":"nitrites","range":"(0,4 – 10) mg/l"},{"name":"bromides","range":"(0,4 – 10) mg/l"},{"name":"nitrates","range":"(0,4 – 10) mg/l"},{"name":"orthophosphates","range":"(0,4 – 10) mg/l"},{"name":"sulfates","range":"(0,5 – 10) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"technique_en":"Ion chromatography (IC)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,4 – 10) mg/l\nchlorki (0,4 – 10) mg/l\nazotyny (0,4 – 10) mg/l\nbromki (0,4 – 10) mg/l\nazotany (0,4 – 10) mg/l\nortofosforany (0,4 – 10) mg/l\nsiarczany (0,5 – 10) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nfluorki (0,4 – 10) mg/l\nchlorki (0,4 – 10) mg/l\nazotyny (0,4 – 10) mg/l\nbromki (0,4 – 10) mg/l\nazotany (0,4 – 10) mg/l\nortofosforany (0,4 – 10) mg/l\nsiarczany (0,5 – 10) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012 Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nfluorki (0,4 – 10) mg/l\nchlorki (0,4 – 10) mg/l\nazotyny (0,4 – 10) mg/l\nbromki (0,4 – 10) mg/l\nazotany (0,4 – 10) mg/l\nortofosforany (0,4 – 10) mg/l\nsiarczany (0,5 – 10) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Anion concentrations Ion chromatography (IC) fluorides chlorides nitrites bromides nitrates orthophosphates sulfates PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","methodology_zh":"阴离子浓度","search_zh":"生活饮用水 阴离子浓度 离子色谱法（IC） 氟化物 氯化物 亚硝酸盐 溴化物 硝酸盐 正磷酸盐 硫酸盐 PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","test_object_zh":"生活饮用水","parameters_zh":[{"name":"氟化物","range":"(0,4 – 10) mg/l"},{"name":"氯化物","range":"(0,4 – 10) mg/l"},{"name":"亚硝酸盐","range":"(0,4 – 10) mg/l"},{"name":"溴化物","range":"(0,4 – 10) mg/l"},{"name":"硝酸盐","range":"(0,4 – 10) mg/l"},{"name":"正磷酸盐","range":"(0,4 – 10) mg/l"},{"name":"硫酸盐","range":"(0,5 – 10) mg/l"}],"technique_zh":"离子色谱法（IC）"},{"_id":"6a5dc9c3f1c10c8ce825fc22","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(5,0 – 40)°C"}],"parameters_en":[{"name":"Range","range":"(5,0 – 40)°C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (5,0 – 40)°C","reference":"PN-ISO 5667-11:2017-10 z wył. pkt. 4.2.2, 4.2.4, 4.3, 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6, 8.2, 9.3, 9.4 PRB.ŚPP.8I06 wyd. 9 z 03.09.2020 r. pkt 3.3","norm_bases":["PN-ISO 5667-11:2017-10 z wył. pkt. 4.2.2, 4.2.4, 4.3, 5.2, 6.1.2, 6.2, 6.3","PN-ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6, 8.2, 9.3, 9.4 PRB.ŚPP.8I06 wyd. 9 z 03.09.2020 r. pkt 3.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (5,0 – 40)°C PN-ISO 5667-11:2017-10 z wył. pkt. 4.2.2, 4.2.4, 4.3, 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6, 8.2, 9.3, 9.4 PRB.ŚPP.8I06 wyd. 9 z 03.09.2020 r. pkt 3.3 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (5,0 – 40)°C PN-ISO 5667-11:2017-10 z wyl. pkt. 4.2.2, 4.2.4, 4.3, 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wyl. pkt. 7.2, 7.5, 7.6, 8.2, 9.3, 9.4 PRB.SPP.8I06 wyd. 9 z 03.09.2020 r. pkt 3.3","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-11:2017-10 z wył. pkt. 4.2.2, 4.2.4, 4.3, 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6, 8.2, 9.3, 9.4 PRB.ŚPP.8I06 wyd. 9 z 03.09.2020 r. pkt 3.3","parameters_zh":[{"name":"范围","range":"(5,0 – 40)°C"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-11:2017-10 z wył. pkt. 4.2.2, 4.2.4, 4.3, 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.5, 7.6, 8.2, 9.3, 9.4 PRB.ŚPP.8I06 wyd. 9 z 03.09.2020 r. pkt 3.3","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9c3f1c10c8ce825fc23","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","methodology_en":"Chemical oxygen demand – COD-Cr","parameters":[{"name":"Zakres","range":"(30 – 2000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(30 – 2000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 2000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 2000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (30 – 2000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Titrimetric method Range PN-ISO 6060:2006","parameters_zh":[{"name":"范围","range":"(30 – 2000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a5dc9c3f1c10c8ce825fc24","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","methodology_en":"Chemical oxygen demand – COD-Cr","parameters":[{"name":"Zakres","range":"(10 – 30000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(10 – 30000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10 – 30000) mg/l O2\nMetoda miareczkowa","reference":"PRB.ŚPP.8I21 wydanie 8 z 16.04.2024","norm_bases":["PRB.ŚPP.8I21 wydanie 8 z 16.04.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10 – 30000) mg/l O2\nMetoda miareczkowa PRB.ŚPP.8I21 wydanie 8 z 16.04.2024 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10 – 30000) mg/l O2\nMetoda miareczkowa PRB.SPP.8I21 wydanie 8 z 16.04.2024","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Titrimetric method Range PRB.ŚPP.8I21 wydanie 8 z 16.04.2024","parameters_zh":[{"name":"范围","range":"(10 – 30000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 滴定法 范围 PRB.ŚPP.8I21 wydanie 8 z 16.04.2024","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a5dc9c3f1c10c8ce825fc25","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc26","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 20000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 20000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 20000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 20000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 20000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 20000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc27","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,002 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,002 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,002 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,002 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,002 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","parameters_zh":[{"name":"范围","range":"(0,002 – 200) mg/l"}],"search_zh":"水、废水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a5dc9c3f1c10c8ce825fc28","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc29","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Substancje rozpuszczone","methodology_en":"Dissolved solids","parameters":[{"name":"Zakres","range":"(100– 10000) mg/l"}],"parameters_en":[{"name":"Range","range":"(100– 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje rozpuszczone\nZakres (100– 10000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Substancje rozpuszczone\nZakres (100– 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Substancje rozpuszczone\nZakres (100– 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(100– 10000) mg/l"}],"search_zh":"水、废水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性固体"},{"_id":"6a5dc9c3f1c10c8ce825fc2a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 – 2000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 – 2000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 2000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (5 – 2000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (5 – 2000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 2000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc2b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 10000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 10000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 – 10000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc2c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(20 – 200) mg/l"},{"name":"Zakres","range":"(200 – 20 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 200) mg/l"},{"name":"Range","range":"(200 – 20 000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres:\nZakres (20 – 200) mg/l\nZakres (200 – 20 000) mg/l\nMetoda spektrofotometryczna","reference":"Nanocolor test 0-62 w. 02.17 Nanocolor test 0-63 w. 09.19","norm_bases":["Nanocolor test 0-62 w. 02.17 Nanocolor test 0-63 w. 09.19"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres:\nZakres (20 – 200) mg/l\nZakres (200 – 20 000) mg/l\nMetoda spektrofotometryczna Nanocolor test 0-62 w. 02.17 Nanocolor test 0-63 w. 09.19 Woda, scieki Stezenie siarczanow\nZakres:\nZakres (20 – 200) mg/l\nZakres (200 – 20 000) mg/l\nMetoda spektrofotometryczna Nanocolor test 0-62 w. 02.17 Nanocolor test 0-63 w. 09.19","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Range Range Nanocolor test 0-62 w. 02.17 Nanocolor test 0-63 w. 09.19","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20 – 200) mg/l"},{"name":"范围","range":"(200 – 20 000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 范围 范围 Nanocolor test 0-62 w. 02.17 Nanocolor test 0-63 w. 09.19","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc2d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczków","methodology_en":"Sulfide concentration","parameters":[{"name":"Zakres","range":"(0,05 – 3,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczków\nZakres (0,05 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"Nanocolor test 0-73 w. 06.17","norm_bases":["Nanocolor test 0-73 w. 06.17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczków\nZakres (0,05 – 3,0) mg/l\nMetoda spektrofotometryczna Nanocolor test 0-73 w. 06.17 Woda, scieki Stezenie siarczkow\nZakres (0,05 – 3,0) mg/l\nMetoda spektrofotometryczna Nanocolor test 0-73 w. 06.17","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfide concentration Spectrophotometric method Range Nanocolor test 0-73 w. 06.17","parameters_zh":[{"name":"范围","range":"(0,05 – 3,0) mg/l"}],"search_zh":"水、废水 硫化物浓度 分光光度法 范围 Nanocolor test 0-73 w. 06.17","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"硫化物浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc2e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(5 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 20) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5 – 20) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (5 – 20) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (5 – 20) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5 – 20) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc2f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,33 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,33 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,33 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie jonu amonowego\nZakres (0,33 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie jonu amonowego\nZakres (0,33 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium ion concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,33 – 1000) mg/l"}],"search_zh":"水、废水 铵离子浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc30","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,0125 – 12) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0125 – 12) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0125 – 12) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0125 – 12) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0125 – 12) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0125 – 12) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc31","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,08 – 5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,08 – 5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,08 – 5) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,08 – 5) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,08 – 5) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,08 – 5) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc32","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 – 26,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 26,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 26,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN 6878:2006 punkt 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 26,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 punkt 8 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,05 – 26,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 26,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN 6878:2006 punkt 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc33","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,3 – 15,0) mg/l"},{"name":"Zakres","range":"(5 - 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,3 – 15,0) mg/l"},{"name":"Range","range":"(5 - 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres:\nZakres (0,3 – 15,0) mg/l\nZakres (5 - 50) mg/l\nMetoda spektrofotometryczna","reference":"Nanocolor test 0-80 w. 03.14 Nanocolor test 0-55 w. 04.14","norm_bases":["Nanocolor test 0-80 w. 03.14 Nanocolor test 0-55 w. 04.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres:\nZakres (0,3 – 15,0) mg/l\nZakres (5 - 50) mg/l\nMetoda spektrofotometryczna Nanocolor test 0-80 w. 03.14 Nanocolor test 0-55 w. 04.14 Woda, scieki Stezenie fosforu ogolnego\nZakres:\nZakres (0,3 – 15,0) mg/l\nZakres (5 - 50) mg/l\nMetoda spektrofotometryczna Nanocolor test 0-80 w. 03.14 Nanocolor test 0-55 w. 04.14","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range Range Nanocolor test 0-80 w. 03.14 Nanocolor test 0-55 w. 04.14","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 15,0) mg/l"},{"name":"范围","range":"(5 - 50) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 范围 Nanocolor test 0-80 w. 03.14 Nanocolor test 0-55 w. 04.14","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc34","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,1 – 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,1 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN 6878:2006 punkt 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,1 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 punkt 4 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,1 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,1 – 20,0) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN 6878:2006 punkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc35","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów anionowych","methodology_en":"Anionic surfactant concentration","parameters":[{"name":"Zakres","range":"(0,1 – 5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów anionowych\nZakres (0,1 – 5) mg/l\nMetoda spektrofotometryczna","reference":"PRB.ŚPP.8I39 wydanie 7 z dnia 31.03.2025","norm_bases":["PRB.ŚPP.8I39 wydanie 7 z dnia 31.03.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów anionowych\nZakres (0,1 – 5) mg/l\nMetoda spektrofotometryczna PRB.ŚPP.8I39 wydanie 7 z dnia 31.03.2025 Woda, scieki Stezenie surfaktantow anionowych\nZakres (0,1 – 5) mg/l\nMetoda spektrofotometryczna PRB.SPP.8I39 wydanie 7 z dnia 31.03.2025","categories":["water"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Anionic surfactant concentration Spectrophotometric method Range PRB.ŚPP.8I39 wydanie 7 z dnia 31.03.2025","parameters_zh":[{"name":"范围","range":"(0,1 – 5) mg/l"}],"search_zh":"水、废水 阴离子表面活性剂浓度 分光光度法 范围 PRB.ŚPP.8I39 wydanie 7 z dnia 31.03.2025","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"阴离子表面活性剂浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc36","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów niejonowych","methodology_en":"Non-ionic surfactant concentration","parameters":[{"name":"Zakres","range":"(0,1 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów niejonowych\nZakres (0,1 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PRB.ŚPP.8I15 wydanie 1 z dnia 31.03.2025","norm_bases":["PRB.ŚPP.8I15 wydanie 1 z dnia 31.03.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów niejonowych\nZakres (0,1 – 10) mg/l\nMetoda spektrofotometryczna PRB.ŚPP.8I15 wydanie 1 z dnia 31.03.2025 Woda, scieki Stezenie surfaktantow niejonowych\nZakres (0,1 – 10) mg/l\nMetoda spektrofotometryczna PRB.SPP.8I15 wydanie 1 z dnia 31.03.2025","categories":["water"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Non-ionic surfactant concentration Spectrophotometric method Range PRB.ŚPP.8I15 wydanie 1 z dnia 31.03.2025","parameters_zh":[{"name":"范围","range":"(0,1 – 10) mg/l"}],"search_zh":"水、废水 非离子表面活性剂浓度 分光光度法 范围 PRB.ŚPP.8I15 wydanie 1 z dnia 31.03.2025","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"非离子表面活性剂浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc37","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów anionowych","methodology_en":"Anionic surfactant concentration","parameters":[{"name":"Zakres","range":"(0,1 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów anionowych\nZakres (0,1 – 10) mg/l\nMetoda spektrofotometryczna","reference":"Test HACH LCK 43208/2022, Wydanie 3","norm_bases":["Test HACH LCK 43208/2022, Wydanie 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów anionowych\nZakres (0,1 – 10) mg/l\nMetoda spektrofotometryczna Test HACH LCK 43208/2022, Wydanie 3 Woda, scieki Stezenie surfaktantow anionowych\nZakres (0,1 – 10) mg/l\nMetoda spektrofotometryczna Test HACH LCK 43208/2022, Wydanie 3","categories":["water"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Anionic surfactant concentration Spectrophotometric method Range Test HACH LCK 43208/2022, Wydanie 3","parameters_zh":[{"name":"范围","range":"(0,1 – 10) mg/l"}],"search_zh":"水、废水 阴离子表面活性剂浓度 分光光度法 范围 Test HACH LCK 43208/2022, Wydanie 3","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"阴离子表面活性剂浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc38","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów niejonowych","methodology_en":"Non-ionic surfactant concentration","parameters":[{"name":"Zakres","range":"(0,2 – 15) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,2 – 15) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów niejonowych\nZakres (0,2 – 15) mg/l\nMetoda spektrofotometryczna","reference":"Test HACH LCK 33302/2024, Wydanie 4","norm_bases":["Test HACH LCK 33302/2024, Wydanie 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów niejonowych\nZakres (0,2 – 15) mg/l\nMetoda spektrofotometryczna Test HACH LCK 33302/2024, Wydanie 4 Woda, scieki Stezenie surfaktantow niejonowych\nZakres (0,2 – 15) mg/l\nMetoda spektrofotometryczna Test HACH LCK 33302/2024, Wydanie 4","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Non-ionic surfactant concentration Spectrophotometric method Range Test HACH LCK 33302/2024, Wydanie 4","parameters_zh":[{"name":"范围","range":"(0,2 – 15) mg/l"}],"search_zh":"水、废水 非离子表面活性剂浓度 分光光度法 范围 Test HACH LCK 33302/2024, Wydanie 4","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"非离子表面活性剂浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc39","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie absorbowalnych, organicznych związków","methodology_en":"Concentration of absorbable, organic compounds","parameters":[{"name":"chlorowcowych AOX"},{"name":"Zakres","range":"(0,01 –1700) mg/l Cl"}],"parameters_en":[{"name":"halogenated AOX"},{"name":"Range","range":"(0,01 –1700) mg/l Cl"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją kulometryczną","techniques":["Metoda wysokotemperaturowego spalania z detekcją kulometryczną"],"technique_en":"High-temperature combustion method with coulometric detection","computed":[],"computed_en":[],"activity":"Stężenie absorbowalnych, organicznych związków\nZakres:\nchlorowcowych AOX\nZakres (0,01 –1700) mg/l Cl\nMetoda wysokotemperaturowego spalania z detekcją kulometryczną","reference":"PN-EN ISO 9562:2007","norm_bases":["PN-EN ISO 9562:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie absorbowalnych, organicznych związków\nZakres:\nchlorowcowych AOX\nZakres (0,01 –1700) mg/l Cl\nMetoda wysokotemperaturowego spalania z detekcją kulometryczną PN-EN ISO 9562:2007 Woda, scieki Stezenie absorbowalnych, organicznych zwiazkow\nZakres:\nchlorowcowych AOX\nZakres (0,01 –1700) mg/l Cl\nMetoda wysokotemperaturowego spalania z detekcja kulometryczna PN-EN ISO 9562:2007","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of absorbable, organic compounds High-temperature combustion method with coulometric detection halogenated AOX Range PN-EN ISO 9562:2007","parameters_zh":[{"name":"chlorowcowych AOX"},{"name":"范围","range":"(0,01 –1700) mg/l Cl"}],"search_zh":"水、废水 范围 PN-EN ISO 9562:2007","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc3a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie jednopierścieniowych węglowodorów aromatycznych (BTEX)","methodology_en":"Monocyclic aromatic hydrocarbons (BTEX) concentration","parameters":[{"name":"benzen","range":"(1 -1000) μg/l"},{"name":"toluen","range":"(5 -1000) μg/l"},{"name":"etylobenzen","range":"(5 -1000) μg/l"},{"name":"(m+p)-ksylen","range":"(10 – 2000) μg/l"},{"name":"o-ksylen","range":"(5 -1000) μg/l"}],"parameters_en":[{"name":"benzene","range":"(1 -1000) μg/l"},{"name":"toluene","range":"(5 -1000) μg/l"},{"name":"ethylbenzene","range":"(5 -1000) μg/l"},{"name":"(m+p)-xylene","range":"(10 – 2000) μg/l"},{"name":"o-xylene","range":"(5 -1000) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)"],"technique_en":"Headspace gas chromatography with flame ionization detection (HS-GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie jednopierścieniowych węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (1 -1000) μg/l\ntoluen (5 -1000) μg/l\netylobenzen (5 -1000) μg/l\n(m+p)-ksylen (10 – 2000) μg/l\no-ksylen (5 -1000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID)","reference":"PN-EN ISO 11423-1:2002","norm_bases":["PN-EN ISO 11423-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie jednopierścieniowych węglowodorów aromatycznych (BTEX)\nZakres:\nbenzen (1 -1000) μg/l\ntoluen (5 -1000) μg/l\netylobenzen (5 -1000) μg/l\n(m+p)-ksylen (10 – 2000) μg/l\no-ksylen (5 -1000) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją płomieniowo-jonizacyjną (HS-GC-FID) PN-EN ISO 11423-1:2002 Woda, scieki Stezenie jednopierscieniowych weglowodorow aromatycznych (BTEX)\nZakres:\nbenzen (1 -1000) μg/l\ntoluen (5 -1000) μg/l\netylobenzen (5 -1000) μg/l\n(m+p)-ksylen (10 – 2000) μg/l\no-ksylen (5 -1000) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja plomieniowo-jonizacyjna (HS-GC-FID) PN-EN ISO 11423-1:2002","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Monocyclic aromatic hydrocarbons (BTEX) concentration Headspace gas chromatography with flame ionization detection (HS-GC-FID) benzene toluene ethylbenzene (m+p)-xylene o-xylene PN-EN ISO 11423-1:2002","search_zh":"水、废水 顶空气相色谱-火焰离子化检测法（HS-GC-FID） 苯 甲苯 乙苯 (间+对)-二甲苯 邻二甲苯 PN-EN ISO 11423-1:2002","test_object_zh":"水、废水","parameters_zh":[{"name":"苯","range":"(1 -1000) μg/l"},{"name":"甲苯","range":"(5 -1000) μg/l"},{"name":"乙苯","range":"(5 -1000) μg/l"},{"name":"(间+对)-二甲苯","range":"(10 – 2000) μg/l"},{"name":"邻二甲苯","range":"(5 -1000) μg/l"}],"technique_zh":"顶空气相色谱-火焰离子化检测法（HS-GC-FID）"},{"_id":"6a5dc9c3f1c10c8ce825fc3b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma BTEX (z obliczeń)","methodology_en":"Sum of BTEX (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTEX (z obliczeń)","reference":"PN-EN ISO 11423-1:2002","norm_bases":["PN-EN ISO 11423-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma BTEX (z obliczeń) PN-EN ISO 11423-1:2002 Woda, scieki Suma BTEX (z obliczen) PN-EN ISO 11423-1:2002","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sum of BTEX (calculated) PN-EN ISO 11423-1:2002","search_zh":"水、废水 BTEX 总量（由计算得出） PN-EN ISO 11423-1:2002","test_object_zh":"水、废水","methodology_zh":"BTEX 总量（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc3c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie łatwo lotnych chlorowcopochodnych węglowodorów:","methodology_en":"Concentration of highly volatile halogenated hydrocarbons:","parameters":[{"name":"1,2-dichloroetan","range":"(5 – 1000) μg/l"},{"name":"chloroform","range":"(0,3 – 100) μg/l"},{"name":"trichloroetylen","range":"(0,5 – 60) μg/l"},{"name":"1,2,3-TCB","range":"(0,5 – 100) μg/l"},{"name":"1,2,4-TCB","range":"(0,5 – 100) μg/l"},{"name":"1,3,5-TCB","range":"(0,5 – 100) μg/l"},{"name":"heksachlorobenzen","range":"(0,1 – 10) μg/l"}],"parameters_en":[{"name":"1,2-dichloroethane","range":"(5 – 1000) μg/l"},{"name":"chloroform","range":"(0,3 – 100) μg/l"},{"name":"trichloroethylene","range":"(0,5 – 60) μg/l"},{"name":"1,2,3-TCB","range":"(0,5 – 100) μg/l"},{"name":"1,2,4-TCB","range":"(0,5 – 100) μg/l"},{"name":"1,3,5-TCB","range":"(0,5 – 100) μg/l"},{"name":"hexachlorobenzene","range":"(0,1 – 10) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD)"],"technique_en":"Headspace gas chromatography with electron capture detection (HS-GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie łatwo lotnych chlorowcopochodnych węglowodorów:\nZakres:\n1,2-dichloroetan (5 – 1000) μg/l\nchloroform (0,3 – 100) μg/l\ntrichloroetylen (0,5 – 60) μg/l\n1,2,3-TCB (0,5 – 100) μg/l\n1,2,4-TCB (0,5 – 100) μg/l\n1,3,5-TCB (0,5 – 100) μg/l\nheksachlorobenzen (0,1 – 10) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie łatwo lotnych chlorowcopochodnych węglowodorów:\nZakres:\n1,2-dichloroetan (5 – 1000) μg/l\nchloroform (0,3 – 100) μg/l\ntrichloroetylen (0,5 – 60) μg/l\n1,2,3-TCB (0,5 – 100) μg/l\n1,2,4-TCB (0,5 – 100) μg/l\n1,3,5-TCB (0,5 – 100) μg/l\nheksachlorobenzen (0,1 – 10) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Woda, scieki Stezenie latwo lotnych chlorowcopochodnych weglowodorow:\nZakres:\n1,2-dichloroetan (5 – 1000) μg/l\nchloroform (0,3 – 100) μg/l\ntrichloroetylen (0,5 – 60) μg/l\n1,2,3-TCB (0,5 – 100) μg/l\n1,2,4-TCB (0,5 – 100) μg/l\n1,3,5-TCB (0,5 – 100) μg/l\nheksachlorobenzen (0,1 – 10) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of highly volatile halogenated hydrocarbons: Headspace gas chromatography with electron capture detection (HS-GC-ECD) 1,2-dichloroethane chloroform trichloroethylene 1,2,3-TCB 1,2,4-TCB 1,3,5-TCB hexachlorobenzene PN-EN ISO 10301:2002","search_zh":"水、废水 1,2-二氯乙烷 三氯甲烷 三氯乙烯 六氯苯 PN-EN ISO 10301:2002","test_object_zh":"水、废水","parameters_zh":[{"name":"1,2-二氯乙烷","range":"(5 – 1000) μg/l"},{"name":"三氯甲烷","range":"(0,3 – 100) μg/l"},{"name":"三氯乙烯","range":"(0,5 – 60) μg/l"},{"name":"1,2,3-TCB","range":"(0,5 – 100) μg/l"},{"name":"1,2,4-TCB","range":"(0,5 – 100) μg/l"},{"name":"1,3,5-TCB","range":"(0,5 – 100) μg/l"},{"name":"六氯苯","range":"(0,1 – 10) μg/l"}]},{"_id":"6a5dc9c3f1c10c8ce825fc3d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks oleju mineralnego (węglowodory ropopochodne)","methodology_en":"Mineral oil index (petroleum hydrocarbons)","parameters":[{"name":"Zakres","range":"(0,11 - 40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,11 - 40) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego (węglowodory ropopochodne)\nZakres (0,11 - 40) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks oleju mineralnego (węglowodory ropopochodne)\nZakres (0,11 - 40) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego (weglowodory ropopochodne)\nZakres (0,11 - 40) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Mineral oil index (petroleum hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,11 - 40) mg/l"}],"search_zh":"水、废水 矿物油指数（石油类烃） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数（石油类烃）"},{"_id":"6a5dc9c3f1c10c8ce825fc3e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali:","methodology_en":"Metal concentrations:","parameters":[{"name":"chrom","range":"(0,01 – 1,00) mg/l"},{"name":"miedź","range":"(0,01 – 1,00) mg/l"},{"name":"nikiel","range":"(0,01 – 1,00) mg/l"},{"name":"kadm","range":"(0,005 – 1,00) mg/l"},{"name":"ołów","range":"(0,01 – 1,00) mg/l"},{"name":"cynk","range":"(0,01 – 1,00) mg/l"},{"name":"arsen","range":"(0,005 – 0,1) mg/l"},{"name":"molibden","range":"(0,01 – 1,0) mg/l"},{"name":"antymon","range":"(0,01 – 1,0) mg/l"},{"name":"tal","range":"(0,01 – 1,0) mg/l"}],"parameters_en":[{"name":"chromium","range":"(0,01 – 1,00) mg/l"},{"name":"copper","range":"(0,01 – 1,00) mg/l"},{"name":"nickel","range":"(0,01 – 1,00) mg/l"},{"name":"cadmium","range":"(0,005 – 1,00) mg/l"},{"name":"lead","range":"(0,01 – 1,00) mg/l"},{"name":"zinc","range":"(0,01 – 1,00) mg/l"},{"name":"arsenic","range":"(0,005 – 0,1) mg/l"},{"name":"molybdenum","range":"(0,01 – 1,0) mg/l"},{"name":"antimony","range":"(0,01 – 1,0) mg/l"},{"name":"thallium","range":"(0,01 – 1,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie metali:\nZakres:\nchrom (0,01 – 1,00) mg/l\nmiedź (0,01 – 1,00) mg/l\nnikiel (0,01 – 1,00) mg/l\nkadm (0,005 – 1,00) mg/l\nołów (0,01 – 1,00) mg/l\ncynk (0,01 – 1,00) mg/l\narsen (0,005 – 0,1) mg/l\nmolibden (0,01 – 1,0) mg/l\nantymon (0,01 – 1,0) mg/l\ntal (0,01 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali:\nZakres:\nchrom (0,01 – 1,00) mg/l\nmiedź (0,01 – 1,00) mg/l\nnikiel (0,01 – 1,00) mg/l\nkadm (0,005 – 1,00) mg/l\nołów (0,01 – 1,00) mg/l\ncynk (0,01 – 1,00) mg/l\narsen (0,005 – 0,1) mg/l\nmolibden (0,01 – 1,0) mg/l\nantymon (0,01 – 1,0) mg/l\ntal (0,01 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali:\nZakres:\nchrom (0,01 – 1,00) mg/l\nmiedz (0,01 – 1,00) mg/l\nnikiel (0,01 – 1,00) mg/l\nkadm (0,005 – 1,00) mg/l\nolow (0,01 – 1,00) mg/l\ncynk (0,01 – 1,00) mg/l\narsen (0,005 – 0,1) mg/l\nmolibden (0,01 – 1,0) mg/l\nantymon (0,01 – 1,0) mg/l\ntal (0,01 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) chromium copper nickel cadmium lead zinc arsenic molybdenum antimony thallium PN-EN ISO 11885:2009","parameters_zh":[{"name":"铬","range":"(0,01 – 1,00) mg/l"},{"name":"铜","range":"(0,01 – 1,00) mg/l"},{"name":"镍","range":"(0,01 – 1,00) mg/l"},{"name":"镉","range":"(0,005 – 1,00) mg/l"},{"name":"铅","range":"(0,01 – 1,00) mg/l"},{"name":"锌","range":"(0,01 – 1,00) mg/l"},{"name":"砷","range":"(0,005 – 0,1) mg/l"},{"name":"钼","range":"(0,01 – 1,0) mg/l"},{"name":"锑","range":"(0,01 – 1,0) mg/l"},{"name":"铊","range":"(0,01 – 1,0) mg/l"}],"search_zh":"水、废水 金属浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 铬 铜 镍 镉 铅 锌 砷 钼 锑 铊 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水","methodology_zh":"金属浓度："},{"_id":"6a5dc9c3f1c10c8ce825fc3f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0015 – 1) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0015 – 1) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0015 – 1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 1483:2007","norm_bases":["PN-EN 1483:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,0015 – 1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 1483:2007 Woda, scieki Stezenie rteci\nZakres (0,0015 – 1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 1483:2007","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 1483:2007","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0015 – 1) mg/l"}],"search_zh":"水、废水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 1483:2007","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc40","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,04 – 50) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 50) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,04 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012","norm_bases":["PN-EN ISO 12846:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,04 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 Woda, scieki Stezenie rteci\nZakres (0,04 – 50) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 50) μg/l"}],"search_zh":"水、废水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc41","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ogólnego węgla organicznego","methodology_en":"Total organic carbon concentration","parameters":[{"name":"Zakres","range":"(0,5 – 2700) mg/l C"},{"name":"Zakres","range":"(0,5 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 2700) mg/l C"},{"name":"Range","range":"(0,5 – 5000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR; Metoda utleniania w warunkach nadkrytycznej wody (SCWO) z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR","Metoda utleniania w warunkach nadkrytycznej wody (SCWO) z detekcją IR"],"technique_en":"High-temperature combustion method with IR detection; Supercritical water oxidation method (SCWO) with IR detection","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres:\nZakres (0,5 – 2700) mg/l C\nZakres (0,5 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR; Metoda utleniania w warunkach nadkrytycznej wody (SCWO) z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego\nZakres:\nZakres (0,5 – 2700) mg/l C\nZakres (0,5 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR; Metoda utleniania w warunkach nadkrytycznej wody (SCWO) z detekcją IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego\nZakres:\nZakres (0,5 – 2700) mg/l C\nZakres (0,5 – 5000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR; Metoda utleniania w warunkach nadkrytycznej wody (SCWO) z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total organic carbon concentration High-temperature combustion method with IR detection; Supercritical water oxidation method (SCWO) with IR detection Range Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(0,5 – 2700) mg/l C"},{"name":"范围","range":"(0,5 – 5000) mg/l"}],"search_zh":"水、废水 总有机碳浓度 范围 范围 PN-EN 1484:1999","test_object_zh":"水、废水","methodology_zh":"总有机碳浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc42","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c3f1c10c8ce825fc43","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(3 - 5000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 - 5000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 - 5000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN-ISO 5815-1:2019-12","norm_bases":["PN-EN-ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 - 5000) mg/l O2\nMetoda elektrochemiczna PN-EN-ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 - 5000) mg/l O2\nMetoda elektrochemiczna PN-EN-ISO 5815-1:2019-12","categories":["water"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN-ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 - 5000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN-ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c3f1c10c8ce825fc44","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem pkt.7.2 | ISO 17289:2014","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem pkt.7.2","ISO 17289:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem pkt.7.2 | ISO 17289:2014 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem pkt.7.2 | ISO 17289:2014","categories":["water"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN 1899-2:2002 z wyłączeniem pkt.7.2 | ISO 17289:2014","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 范围 PN-EN 1899-2:2002 z wyłączeniem pkt.7.2 | ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c3f1c10c8ce825fc45","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(3 - 5000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 - 5000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 - 5000) mg/l O2\nMetoda optyczna","reference":"PN-EN-ISO 5815-1:2019-12","norm_bases":["PN-EN-ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 - 5000) mg/l O2\nMetoda optyczna PN-EN-ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 - 5000) mg/l O2\nMetoda optyczna PN-EN-ISO 5815-1:2019-12","categories":["water"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN-ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 - 5000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 范围 PN-EN-ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c3f1c10c8ce825fc46","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma chlorofenoli","methodology_en":"Sum of chlorophenols","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l"},{"name":"w przeliczeniu na 2,4-dichlorofenol"}],"parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l"},{"name":"calculated as 2,4-dichlorophenol"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Suma chlorofenoli\nZakres:\nZakres (5 – 1000) mg/l\nw przeliczeniu na 2,4-dichlorofenol\nMetoda miareczkowa","reference":"PRB.ŚPP.8I30 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I30 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma chlorofenoli\nZakres:\nZakres (5 – 1000) mg/l\nw przeliczeniu na 2,4-dichlorofenol\nMetoda miareczkowa PRB.ŚPP.8I30 wydanie 4 z 2016-10-03 Woda, scieki Suma chlorofenoli\nZakres:\nZakres (5 – 1000) mg/l\nw przeliczeniu na 2,4-dichlorofenol\nMetoda miareczkowa PRB.SPP.8I30 wydanie 4 z 2016-10-03","categories":["water"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sum of chlorophenols Titrimetric method Range calculated as 2,4-dichlorophenol PRB.ŚPP.8I30 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l"},{"name":"w przeliczeniu na 2,4-dichlorofenol"}],"search_zh":"水、废水 滴定法 范围 PRB.ŚPP.8I30 wydanie 4 z 2016-10-03","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c3f1c10c8ce825fc47","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chromu (VI)","methodology_en":"Chromium(VI) concentration","parameters":[{"name":"Zakres","range":"(4 – 80) μg/l"}],"parameters_en":[{"name":"Range","range":"(4 – 80) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu (VI)\nZakres (4 – 80) μg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chromu (VI)\nZakres (4 – 80) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda, scieki Stezenie chromu (VI)\nZakres (4 – 80) μg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","parameters_zh":[{"name":"范围","range":"(4 – 80) μg/l"}],"search_zh":"水、废水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc48","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie kationów","methodology_en":"Cation concentrations","parameters":[{"name":"Lit","range":"(0,02 – 1,0) mg/l"},{"name":"Sód","range":"(0,1 – 50) mg/l"},{"name":"Jon amonowy","range":"(0,1 – 5,0) mg/l"},{"name":"Potas","range":"(0,1 – 20) mg/l"},{"name":"Wapń","range":"(0,5 – 100) mg/l"},{"name":"Magnez","range":"(0,5 – 12) mg/l"}],"parameters_en":[{"name":"Lithium","range":"(0,02 – 1,0) mg/l"},{"name":"Sodium","range":"(0,1 – 50) mg/l"},{"name":"Ammonium ion","range":"(0,1 – 5,0) mg/l"},{"name":"Potassium","range":"(0,1 – 20) mg/l"},{"name":"Calcium","range":"(0,5 – 100) mg/l"},{"name":"Magnesium","range":"(0,5 – 12) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"technique_en":"Ion chromatography (IC)","computed":[],"computed_en":[],"activity":"Stężenie kationów\nZakres:\nLit (0,02 – 1,0) mg/l\nSód (0,1 – 50) mg/l\nJon amonowy (0,1 – 5,0) mg/l\nPotas (0,1 – 20) mg/l\nWapń (0,5 – 100) mg/l\nMagnez (0,5 – 12) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie kationów\nZakres:\nLit (0,02 – 1,0) mg/l\nSód (0,1 – 50) mg/l\nJon amonowy (0,1 – 5,0) mg/l\nPotas (0,1 – 20) mg/l\nWapń (0,5 – 100) mg/l\nMagnez (0,5 – 12) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 14911:2002 Woda, scieki Stezenie kationow\nZakres:\nLit (0,02 – 1,0) mg/l\nSod (0,1 – 50) mg/l\nJon amonowy (0,1 – 5,0) mg/l\nPotas (0,1 – 20) mg/l\nWapn (0,5 – 100) mg/l\nMagnez (0,5 – 12) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 14911:2002","categories":["water"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Cation concentrations Ion chromatography (IC) Lithium Sodium Ammonium ion Potassium Calcium Magnesium PN-EN ISO 14911:2002","search_zh":"水、废水 阳离子浓度 离子色谱法（IC） 锂 钠 钾 钙 镁 PN-EN ISO 14911:2002","test_object_zh":"水、废水","technique_zh":"离子色谱法（IC）","parameters_zh":[{"name":"锂","range":"(0,02 – 1,0) mg/l"},{"name":"钠","range":"(0,1 – 50) mg/l"},{"name":"Jon amonowy","range":"(0,1 – 5,0) mg/l"},{"name":"钾","range":"(0,1 – 20) mg/l"},{"name":"钙","range":"(0,5 – 100) mg/l"},{"name":"镁","range":"(0,5 – 12) mg/l"}],"methodology_zh":"阳离子浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc49","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"fluorki","range":"(0,4 – 20) mg/l"},{"name":"chlorki","range":"(0,5 – 450) mg/l"},{"name":"azotyny","range":"(0,4 – 10) mg/l"},{"name":"bromki","range":"(0,4 – 20) mg/l"},{"name":"azotany","range":"(0,4 – 40) mg/l"},{"name":"ortofosforany","range":"(0,4 – 40) mg/l"},{"name":"siarczany","range":"(0,5 – 450) mg/l"}],"parameters_en":[{"name":"fluorides","range":"(0,4 – 20) mg/l"},{"name":"chlorides","range":"(0,5 – 450) mg/l"},{"name":"nitrites","range":"(0,4 – 10) mg/l"},{"name":"bromides","range":"(0,4 – 20) mg/l"},{"name":"nitrates","range":"(0,4 – 40) mg/l"},{"name":"orthophosphates","range":"(0,4 – 40) mg/l"},{"name":"sulfates","range":"(0,5 – 450) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"technique_en":"Ion chromatography (IC)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,4 – 20) mg/l\nchlorki (0,5 – 450) mg/l\nazotyny (0,4 – 10) mg/l\nbromki (0,4 – 20) mg/l\nazotany (0,4 – 40) mg/l\nortofosforany (0,4 – 40) mg/l\nsiarczany (0,5 – 450) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie anionów\nZakres:\nfluorki (0,4 – 20) mg/l\nchlorki (0,5 – 450) mg/l\nazotyny (0,4 – 10) mg/l\nbromki (0,4 – 20) mg/l\nazotany (0,4 – 40) mg/l\nortofosforany (0,4 – 40) mg/l\nsiarczany (0,5 – 450) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012 Woda, scieki Stezenie anionow\nZakres:\nfluorki (0,4 – 20) mg/l\nchlorki (0,5 – 450) mg/l\nazotyny (0,4 – 10) mg/l\nbromki (0,4 – 20) mg/l\nazotany (0,4 – 40) mg/l\nortofosforany (0,4 – 40) mg/l\nsiarczany (0,5 – 450) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","categories":["water"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Anion concentrations Ion chromatography (IC) fluorides chlorides nitrites bromides nitrates orthophosphates sulfates PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","methodology_zh":"阴离子浓度","search_zh":"水、废水 阴离子浓度 离子色谱法（IC） 氟化物 氯化物 亚硝酸盐 溴化物 硝酸盐 正磷酸盐 硫酸盐 PN-EN ISO 10304-1:2009 +PN-EN ISO 10304-1:2009/AC:2012","test_object_zh":"水、废水","parameters_zh":[{"name":"氟化物","range":"(0,4 – 20) mg/l"},{"name":"氯化物","range":"(0,5 – 450) mg/l"},{"name":"亚硝酸盐","range":"(0,4 – 10) mg/l"},{"name":"溴化物","range":"(0,4 – 20) mg/l"},{"name":"硝酸盐","range":"(0,4 – 40) mg/l"},{"name":"正磷酸盐","range":"(0,4 – 40) mg/l"},{"name":"硫酸盐","range":"(0,5 – 450) mg/l"}],"technique_zh":"离子色谱法（IC）"},{"_id":"6a5dc9c3f1c10c8ce825fc4a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość suchej masy","methodology_en":"Dry matter content","parameters":[{"name":"Zakres","range":"(2 – 100) %"}],"parameters_en":[{"name":"Range","range":"(2 – 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy\nZakres (2 – 100) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość suchej masy\nZakres (2 – 100) %\nMetoda wagowa PN-ISO 11465:1999 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc suchej masy\nZakres (2 – 100) %\nMetoda wagowa PN-ISO 11465:1999","categories":["environment"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Dry matter content Gravimetric method Range PN-ISO 11465:1999","parameters_zh":[{"name":"范围","range":"(2 – 100) %"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 干物质含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","methodology_zh":"干物质含量","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc4b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(2 – 100) %"}],"parameters_en":[{"name":"Range","range":"(2 – 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (2 – 100) %\nMetoda wagowa","reference":"PN-ISO 12880:2004","norm_bases":["PN-ISO 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Sucha pozostałość\nZakres (2 – 100) %\nMetoda wagowa PN-ISO 12880:2004 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Sucha pozostalosc\nZakres (2 – 100) %\nMetoda wagowa PN-ISO 12880:2004","categories":["environment"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Dry residue Gravimetric method Range PN-ISO 12880:2004","parameters_zh":[{"name":"范围","range":"(2 – 100) %"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 干残渣 重量法 范围 PN-ISO 12880:2004","technique_zh":"重量法","methodology_zh":"干残渣","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc4c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"miedź","range":"(0,01 – 1) mg/l"},{"name":"ołów","range":"(0,01 – 1) mg/l"},{"name":"kadm","range":"(0,01 – 1) mg/l"},{"name":"chrom","range":"(0,01 – 1) mg/l"},{"name":"nikiel","range":"(0,01 – 1) mg/l"},{"name":"molibden","range":"(0,01 – 1) mg/l"},{"name":"cynk","range":"(0,01 – 1) mg/l"},{"name":"bar","range":"(0,5 – 10) mg/l"},{"name":"arsen","range":"(0,005 – 0,100) mg/l"},{"name":"selen","range":"(0,005 – 0,100) mg/l"},{"name":"antymon","range":"(0,005 – 0,100)mg/l"}],"parameters_en":[{"name":"copper","range":"(0,01 – 1) mg/l"},{"name":"lead","range":"(0,01 – 1) mg/l"},{"name":"cadmium","range":"(0,01 – 1) mg/l"},{"name":"chromium","range":"(0,01 – 1) mg/l"},{"name":"nickel","range":"(0,01 – 1) mg/l"},{"name":"molybdenum","range":"(0,01 – 1) mg/l"},{"name":"zinc","range":"(0,01 – 1) mg/l"},{"name":"barium","range":"(0,5 – 10) mg/l"},{"name":"arsenic","range":"(0,005 – 0,100) mg/l"},{"name":"selenium","range":"(0,005 – 0,100) mg/l"},{"name":"antimony","range":"(0,005 – 0,100)mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nmiedź (0,01 – 1) mg/l\nołów (0,01 – 1) mg/l\nkadm (0,01 – 1) mg/l\nchrom (0,01 – 1) mg/l\nnikiel (0,01 – 1) mg/l\nmolibden (0,01 – 1) mg/l\ncynk (0,01 – 1) mg/l\nbar (0,5 – 10) mg/l\narsen (0,005 – 0,100) mg/l\nselen (0,005 – 0,100) mg/l\nantymon (0,005 – 0,100)mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stężenie metali\nZakres:\nmiedź (0,01 – 1) mg/l\nołów (0,01 – 1) mg/l\nkadm (0,01 – 1) mg/l\nchrom (0,01 – 1) mg/l\nnikiel (0,01 – 1) mg/l\nmolibden (0,01 – 1) mg/l\ncynk (0,01 – 1) mg/l\nbar (0,5 – 10) mg/l\narsen (0,005 – 0,100) mg/l\nselen (0,005 – 0,100) mg/l\nantymon (0,005 – 0,100)mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stezenie metali\nZakres:\nmiedz (0,01 – 1) mg/l\nolow (0,01 – 1) mg/l\nkadm (0,01 – 1) mg/l\nchrom (0,01 – 1) mg/l\nnikiel (0,01 – 1) mg/l\nmolibden (0,01 – 1) mg/l\ncynk (0,01 – 1) mg/l\nbar (0,5 – 10) mg/l\narsen (0,005 – 0,100) mg/l\nselen (0,005 – 0,100) mg/l\nantymon (0,005 – 0,100)mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","categories":["materials","environment"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) copper lead cadmium chromium nickel molybdenum zinc barium arsenic selenium antimony PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","methodology_zh":"金属浓度","parameters_zh":[{"name":"铜","range":"(0,01 – 1) mg/l"},{"name":"铅","range":"(0,01 – 1) mg/l"},{"name":"镉","range":"(0,01 – 1) mg/l"},{"name":"铬","range":"(0,01 – 1) mg/l"},{"name":"镍","range":"(0,01 – 1) mg/l"},{"name":"钼","range":"(0,01 – 1) mg/l"},{"name":"锌","range":"(0,01 – 1) mg/l"},{"name":"钡","range":"(0,5 – 10) mg/l"},{"name":"砷","range":"(0,005 – 0,100) mg/l"},{"name":"硒","range":"(0,005 – 0,100) mg/l"},{"name":"锑","range":"(0,005 – 0,100)mg/l"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 铜 铅 镉 铬 镍 钼 锌 钡 砷 硒 锑 PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc4d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość metali (z obliczeń)","methodology_en":"Metal content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali (z obliczeń)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość metali (z obliczeń) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc metali (z obliczen) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","categories":["materials","environment"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Metal content (calculated) PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 PN-EN ISO 11885:2009 | PN-EN 12457-2:2006","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc4e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Stężenie rozpuszczonego węgla organicznego (DOC)","methodology_en":"Dissolved organic carbon (DOC) concentration","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Stężenie rozpuszczonego węgla organicznego (DOC)\nZakres (1,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999 | PN-EN 12457-2:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stężenie rozpuszczonego węgla organicznego (DOC)\nZakres (1,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stezenie rozpuszczonego wegla organicznego (DOC)\nZakres (1,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 | PN-EN 12457-2:2006","categories":["environment"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Dissolved organic carbon (DOC) concentration High-temperature combustion with IR detection Range PN-EN 1484:1999 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 溶解性有机碳（DOC）浓度 高温燃烧红外检测法 范围 PN-EN 1484:1999 | PN-EN 12457-2:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13","methodology_zh":"溶解性有机碳（DOC）浓度"},{"_id":"6a5dc9c3f1c10c8ce825fc4f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość rozpuszczonego węgla organicznego (DOC) (z obliczeń)","methodology_en":"Dissolved organic carbon (DOC) content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rozpuszczonego węgla organicznego (DOC) (z obliczeń)","reference":"PN-EN 1484:1999 | PN-EN 12457-2:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość rozpuszczonego węgla organicznego (DOC) (z obliczeń) PN-EN 1484:1999 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc rozpuszczonego wegla organicznego (DOC) (z obliczen) PN-EN 1484:1999 | PN-EN 12457-2:2006","categories":["environment"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Dissolved organic carbon (DOC) content (calculated) PN-EN 1484:1999 | PN-EN 12457-2:2006","search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 PN-EN 1484:1999 | PN-EN 12457-2:2006","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc50","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0010 – 1) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0010 – 1) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0010 – 1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 12457-2:2006 | PN-EN 1483:2007","norm_bases":["PN-EN 12457-2:2006","PN-EN 1483:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02 Stężenie rtęci\nZakres (0,0010 – 1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-2:2006 | PN-EN 1483:2007 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02 Stezenie rteci\nZakres (0,0010 – 1) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-2:2006 | PN-EN 1483:2007","categories":["environment"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02 Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 12457-2:2006 | PN-EN 1483:2007","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0010 – 1) mg/l"}],"search_zh":"汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 12457-2:2006 | PN-EN 1483:2007","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a5dc9c3f1c10c8ce825fc51","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02","methodology":"Zawartość rtęci (z obliczeń)","methodology_en":"Mercury content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci (z obliczeń)","reference":"PN-EN 12457-2:2006 | PN-EN 1483:2007","norm_bases":["PN-EN 12457-2:2006","PN-EN 1483:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02 Zawartość rtęci (z obliczeń) PN-EN 12457-2:2006 | PN-EN 1483:2007 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02 Zawartosc rteci (z obliczen) PN-EN 12457-2:2006 | PN-EN 1483:2007","categories":["environment"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 17 05 03* 17 05 04 17 01 01 17 01 02 17 01 07 10 01 05 10 01 01 10 01 02 Mercury content (calculated) PN-EN 12457-2:2006 | PN-EN 1483:2007","methodology_zh":"汞含量（由计算得出）","search_zh":"汞含量（由计算得出） PN-EN 12457-2:2006 | PN-EN 1483:2007"},{"_id":"6a5dc9c3f1c10c8ce825fc52","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(10 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (10 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9297:1994","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stężenie chlorków\nZakres (10 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stezenie chlorkow\nZakres (10 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-2:2006","categories":["environment"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Chloride concentration Titrimetric method Range PN-ISO 9297:1994 | PN-EN 12457-2:2006","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 – 400) mg/l"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 氯化物浓度 滴定法 范围 PN-ISO 9297:1994 | PN-EN 12457-2:2006","technique_zh":"滴定法","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc53","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość chlorków (z obliczeń)","methodology_en":"Chloride content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chlorków (z obliczeń)","reference":"PN-ISO 9297:1994 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9297:1994","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość chlorków (z obliczeń) PN-ISO 9297:1994 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc chlorkow (z obliczen) PN-ISO 9297:1994 | PN-EN 12457-2:2006","categories":["environment"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Chloride content (calculated) PN-ISO 9297:1994 | PN-EN 12457-2:2006","search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 氯化物含量（由计算得出） PN-ISO 9297:1994 | PN-EN 12457-2:2006","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13","methodology_zh":"氯化物含量（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc54","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(10 – 3200) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 3200) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"technique_en":"Ion chromatography (IC)","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (10 – 3200) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009E","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stężenie chlorków\nZakres (10 – 3200) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stezenie chlorkow\nZakres (10 – 3200) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","categories":["environment"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Chloride concentration Ion chromatography (IC) Range PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 – 3200) mg/l"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 氯化物浓度 离子色谱法（IC） 范围 PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","technique_zh":"离子色谱法（IC）","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc55","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość chlorków (z obliczeń)","methodology_en":"Chloride content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chlorków (z obliczeń)","reference":"PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009E","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość chlorków (z obliczeń) PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc chlorkow (z obliczen) PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","categories":["environment"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Chloride content (calculated) PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 氯化物含量（由计算得出） PN-EN ISO 10304-1:2009E | PN-EN 12457-2:2006","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13","methodology_zh":"氯化物含量（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc56","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 400) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 400) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9280:2002","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stężenie siarczanów\nZakres (10 – 400) mg/l\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stezenie siarczanow\nZakres (10 – 400) mg/l\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-2:2006","categories":["environment"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Sulfate concentration Gravimetric method Range PN-ISO 9280:2002 | PN-EN 12457-2:2006","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 400) mg/l"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002 | PN-EN 12457-2:2006","technique_zh":"重量法","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc57","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość siarczanów (z obliczeń)","methodology_en":"Sulphate content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarczanów (z obliczeń)","reference":"PN-ISO 9280:2002 | PN-EN 12457-2:2006","norm_bases":["PN-ISO 9280:2002","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość siarczanów (z obliczeń) PN-ISO 9280:2002 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc siarczanow (z obliczen) PN-ISO 9280:2002 | PN-EN 12457-2:2006","categories":["environment"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Sulphate content (calculated) PN-ISO 9280:2002 | PN-EN 12457-2:2006","search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 硫酸盐含量（由计算得出） PN-ISO 9280:2002 | PN-EN 12457-2:2006","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13","methodology_zh":"硫酸盐含量（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc58","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(12 – 3600) mg/l"}],"parameters_en":[{"name":"Range","range":"(12 – 3600) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"technique_en":"Ion chromatography (IC)","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (12 – 3600) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stężenie siarczanów\nZakres (12 – 3600) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stezenie siarczanow\nZakres (12 – 3600) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","categories":["environment"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Sulfate concentration Ion chromatography (IC) Range PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(12 – 3600) mg/l"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 硫酸盐浓度 离子色谱法（IC） 范围 PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","technique_zh":"离子色谱法（IC）","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc59","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość siarczanów (z obliczeń)","methodology_en":"Sulphate content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarczanów (z obliczeń)","reference":"PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość siarczanów (z obliczeń) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc siarczanow (z obliczen) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","categories":["environment"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Sulphate content (calculated) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 硫酸盐含量（由计算得出） PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13","methodology_zh":"硫酸盐含量（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc5a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,05 – 25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 25) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"technique_en":"Ion chromatography (IC)","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,05 – 25) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stężenie fluorków\nZakres (0,05 – 25) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Stezenie fluorkow\nZakres (0,05 – 25) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","categories":["environment"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Fluoride concentration Ion chromatography (IC) Range PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(0,05 – 25) mg/l"}],"search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 氟化物浓度 离子色谱法（IC） 范围 PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","methodology_zh":"氟化物浓度","technique_zh":"离子色谱法（IC）","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc5b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","test_object_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13","methodology":"Zawartość fluorków (z obliczeń)","methodology_en":"Fluoride content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fluorków (z obliczeń)","reference":"PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartość fluorków (z obliczeń) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006 Odpady kod: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Zawartosc fluorkow (z obliczen) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","categories":["environment"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 06 02 01; 07 04 11; 10 01 07; 10 01 80 19 08 13 Fluoride content (calculated) PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","search_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13 PN-EN ISO 10304-1:2009 | PN-EN 12457-2:2006","test_object_zh":"废物，代码：06 02 01；07 04 11；10 01 07；10 01 80 19 08 13"},{"_id":"6a5dc9c3f1c10c8ce825fc5c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","test_object_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","methodology":"Zawartość suchej masy, zawartość suchej pozostałości","methodology_en":"Dry matter content, dry residue content","parameters":[{"name":"Zakres","range":"(2,0 - 100) %"},{"name":"Zawartość wody (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(2,0 - 100) %"},{"name":"Water content (calculated)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość suchej masy, zawartość suchej pozostałości\nZakres:\nZakres (2,0 - 100) %\nZawartość wody (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zawartość suchej masy, zawartość suchej pozostałości\nZakres:\nZakres (2,0 - 100) %\nZawartość wody (z obliczeń)\nMetoda wagowa PN-EN 15934:2013-02 metoda A Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zawartosc suchej masy, zawartosc suchej pozostalosci\nZakres:\nZakres (2,0 - 100) %\nZawartosc wody (z obliczen)\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["environment","water"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Dry matter content, dry residue content Gravimetric method Range Water content (calculated) PN-EN 15934:2013-02 metoda A","parameters_zh":[{"name":"范围","range":"(2,0 - 100) %"},{"name":"水分含量（计算值）"}],"search_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13* 重量法 范围 水分含量（计算值） PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","test_object_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13*"},{"_id":"6a5dc9c3f1c10c8ce825fc5d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","test_object_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","methodology":"Zawartość całkowitych substancji rozpuszczonych (TDS)","methodology_en":"Total dissolved solids content (TDS)","parameters":[{"name":"Zakres","range":"(1000 – 100 000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(1000 – 100 000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość całkowitych substancji rozpuszczonych (TDS)\nZakres (1000 – 100 000) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-2:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zawartość całkowitych substancji rozpuszczonych (TDS)\nZakres (1000 – 100 000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zawartosc calkowitych substancji rozpuszczonych (TDS)\nZakres (1000 – 100 000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006","categories":["environment"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Total dissolved solids content (TDS) Gravimetric method Range PN-EN 15216:2022-03 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(1000 – 100 000) mg/kg"}],"search_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13* 重量法 范围 PN-EN 15216:2022-03 | PN-EN 12457-2:2006","technique_zh":"重量法","test_object_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13*"},{"_id":"6a5dc9c3f1c10c8ce825fc5e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","test_object_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","methodology":"Zawartość ogólnego węgla organicznego (TOC)","methodology_en":"Total organic carbon (TOC) content","parameters":[{"name":"Zakres","range":"(2000 – 60 000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(2000 – 60 000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres (2000 – 60 000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15936:2022-07 Metoda B","norm_bases":["PN-EN 15936:2022-07 Metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zawartość ogólnego węgla organicznego (TOC)\nZakres (2000 – 60 000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15936:2022-07 Metoda B Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zawartosc ogolnego wegla organicznego (TOC)\nZakres (2000 – 60 000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15936:2022-07 Metoda B","categories":["environment"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Total organic carbon (TOC) content High-temperature combustion with IR detection Range PN-EN 15936:2022-07 Metoda B","parameters_zh":[{"name":"范围","range":"(2000 – 60 000) mg/kg"}],"search_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13* 总有机碳（TOC）含量 高温燃烧红外检测法 范围 PN-EN 15936:2022-07 Metoda B","technique_zh":"高温燃烧红外检测法","methodology_zh":"总有机碳（TOC）含量","test_object_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13*"},{"_id":"6a5dc9c3f1c10c8ce825fc5f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 05 03* 19 08 13*","test_object_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 05 03* 19 08 13*","methodology":"Straty przy prażeniu suchej masy/ suchej pozostałości","methodology_en":"Loss on ignition of dry matter/ dry residue","parameters":[{"name":"Zakres","range":"(2,0 – 100) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy/ suchej pozostałości\nZakres (2,0 – 100) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 05 03* 19 08 13* Straty przy prażeniu suchej masy/ suchej pozostałości\nZakres (2,0 – 100) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 05 03* 19 08 13* Straty przy prazeniu suchej masy/ suchej pozostalosci\nZakres (2,0 – 100) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 05 03* 19 08 13* Loss on ignition of dry matter/ dry residue Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(2,0 – 100) %"}],"search_zh":"重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法"},{"_id":"6a5dc9c3f1c10c8ce825fc60","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 17 05 03* 19 08 13* 06 02 01","test_object_en":"Waste: code: 17 05 03* 19 08 13* 06 02 01","methodology":"Zdolność do neutralizacji kwasów ANC","methodology_en":"Acid neutralisation capacity ANC","parameters":[{"name":"Zakres","range":"(0,8 - 100) mmol/l"},{"name":"Zakres","range":"(40 – 5 000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,8 - 100) mmol/l"},{"name":"Range","range":"(40 – 5 000) mg/l CaCO3"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Zdolność do neutralizacji kwasów ANC\nZakres:\nZakres (0,8 - 100) mmol/l\nZakres (40 – 5 000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego","reference":"PRB.ŚPP.8I10, wersja 1 z 16.06.2024","norm_bases":["PRB.ŚPP.8I10, wersja 1 z 16.06.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 17 05 03* 19 08 13* 06 02 01 Zdolność do neutralizacji kwasów ANC\nZakres:\nZakres (0,8 - 100) mmol/l\nZakres (40 – 5 000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PRB.ŚPP.8I10, wersja 1 z 16.06.2024 Odpady: kod: 17 05 03* 19 08 13* 06 02 01 Zdolnosc do neutralizacji kwasow ANC\nZakres:\nZakres (0,8 - 100) mmol/l\nZakres (40 – 5 000) mg/l CaCO3\nMetoda miareczkowania potencjometrycznego PRB.SPP.8I10, wersja 1 z 16.06.2024","categories":["environment"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 17 05 03* 19 08 13* 06 02 01 Acid neutralisation capacity ANC Potentiometric titration method Range Range PRB.ŚPP.8I10, wersja 1 z 16.06.2024","parameters_zh":[{"name":"范围","range":"(0,8 - 100) mmol/l"},{"name":"范围","range":"(40 – 5 000) mg/l CaCO3"}],"search_zh":"酸中和能力 ANC 电位滴定法 范围 范围 PRB.ŚPP.8I10, wersja 1 z 16.06.2024","technique_zh":"电位滴定法","methodology_zh":"酸中和能力 ANC"},{"_id":"6a5dc9c3f1c10c8ce825fc61","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 17 05 03* 19 08 13* 06 02 01","test_object_en":"Waste: code: 17 05 03* 19 08 13* 06 02 01","methodology":"Zdolność do neutralizacji kwasów ANC w mg/kg (z obliczeń)","methodology_en":"Acid neutralization capacity ANC in mg/kg (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność do neutralizacji kwasów ANC w mg/kg (z obliczeń)","reference":"PRB.ŚPP.8I10, wersja 1 z 16.06.2024","norm_bases":["PRB.ŚPP.8I10, wersja 1 z 16.06.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 17 05 03* 19 08 13* 06 02 01 Zdolność do neutralizacji kwasów ANC w mg/kg (z obliczeń) PRB.ŚPP.8I10, wersja 1 z 16.06.2024 Odpady: kod: 17 05 03* 19 08 13* 06 02 01 Zdolnosc do neutralizacji kwasow ANC w mg/kg (z obliczen) PRB.SPP.8I10, wersja 1 z 16.06.2024","categories":["environment"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 17 05 03* 19 08 13* 06 02 01 Acid neutralization capacity ANC in mg/kg (calculated) PRB.ŚPP.8I10, wersja 1 z 16.06.2024"},{"_id":"6a5dc9c3f1c10c8ce825fc62","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","test_object_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,8 - 100) mmol/l"},{"name":"Zakres","range":"(40 – 5 000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,8 - 100) mmol/l"},{"name":"Range","range":"(40 – 5 000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,8 - 100) mmol/l\nZakres (40 – 5 000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zasadowość ogólna\nZakres:\nZakres (0,8 - 100) mmol/l\nZakres (40 – 5 000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006 Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zasadowosc ogolna\nZakres:\nZakres (0,8 - 100) mmol/l\nZakres (40 – 5 000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","categories":["environment"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Total alkalinity Titrimetric method Range Range PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","parameters_zh":[{"name":"范围","range":"(0,8 - 100) mmol/l"},{"name":"范围","range":"(40 – 5 000) mg/l CaCO3"}],"search_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13* 总碱度 滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","technique_zh":"滴定法","methodology_zh":"总碱度","test_object_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13*"},{"_id":"6a5dc9c3f1c10c8ce825fc63","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","test_object_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13*","methodology":"Zasadowość ogólna w mg/kg (z obliczeń)","methodology_en":"Total alkalinity in mg/kg (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zasadowość ogólna w mg/kg (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004","PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zasadowość ogólna w mg/kg (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006 Odpady: kod: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Zasadowosc ogolna w mg/kg (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","categories":["environment"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code: 06 02 01 10 01 01 10 01 02 10 01 05 17 01 01 17 01 02 17 01 07 17 05 03* 17 05 04 19 08 13* Total alkalinity in mg/kg (calculated) PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","search_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13* PN-EN ISO 9963-1:2001+Ap1:2004 | PN-EN 12457-2:2006","test_object_zh":"废物：代码：06 02 01、10 01 01、10 01 02、10 01 05、17 01 01、17 01 02、17 01 07、17 05 03*、17 05 04、19 08 13*"},{"_id":"6a5dc9c3f1c10c8ce825fc64","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters":[{"name":"Zakres","range":"(10 – 1250) Pa"},{"name":"Prędkość"},{"name":"Zakres","range":"(0,15 – 7) m/s"}],"parameters_en":[{"name":"Range","range":"(10 – 1250) Pa"},{"name":"Velocity"},{"name":"Range","range":"(0,15 – 7) m/s"}],"technique":"Metoda spiętrzenia; Metoda termoanemometryczna","techniques":["Metoda spiętrzenia","Metoda termoanemometryczna"],"technique_en":"Stagnation pressure method; Thermoanemometric method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nZakres (10 – 1250) Pa\nPrędkość\nZakres (0,15 – 7) m/s\nMetoda spiętrzenia; Metoda termoanemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nZakres (10 – 1250) Pa\nPrędkość\nZakres (0,15 – 7) m/s\nMetoda spiętrzenia; Metoda termoanemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nZakres:\nZakres (10 – 1250) Pa\nPredkosc\nZakres (0,15 – 7) m/s\nMetoda spietrzenia; Metoda termoanemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method; Thermoanemometric method Range Velocity Range PN-Z-04030-7:1994","parameters_zh":[{"name":"范围","range":"(10 – 1250) Pa"},{"name":"速度"},{"name":"范围","range":"(0,15 – 7) m/s"}],"search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法；热线风速仪法 范围 速度 范围 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"皮托管法；热线风速仪法"},{"_id":"6a5dc9c3f1c10c8ce825fc65","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9c3f1c10c8ce825fc66","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 5) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 5) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 5) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 5) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 5) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 5) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc67","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc68","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9c3f1c10c8ce825fc69","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,5 – 50) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc6a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc6b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku siarki, dwutlenku węgla","methodology_en":"Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen oxides, sulfur dioxide, carbon dioxide","parameters":[{"name":"O2","range":"(3 – 21) %"}],"parameters_en":[{"name":"O2","range":"(3 – 21) %"}],"technique":"Metoda elektrochemiczna - CO (4,7 – 5700) mg/m3 - NO (2,5 – 850) mg/m3 - NO2 (2,5 – 200) mg/m3 - SO2 (7,85 – 330) mg/m3 - CO2 (0,5 – 18) %; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda elektrochemiczna - CO (4,7 – 5700) mg/m3 - NO (2,5 – 850) mg/m3 - NO2 (2,5 – 200) mg/m3 - SO2 (7,85 – 330) mg/m3 - CO2 (0,5 – 18) %","Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Electrochemical method - CO (4,7 – 5700) mg/m3 - NO (2,5 – 850) mg/m3 - NO2 (2,5 – 200) mg/m3 - SO2 (7,85 – 330) mg/m3 - CO2 (0,5 – 18) %; Non-dispersive infrared spectrometry method (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku siarki, dwutlenku węgla\nO2 (3 – 21) %\nMetoda elektrochemiczna - CO (4,7 – 5700) mg/m3 - NO (2,5 – 850) mg/m3 - NO2 (2,5 – 200) mg/m3 - SO2 (7,85 – 330) mg/m3 - CO2 (0,5 – 18) %; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku siarki, dwutlenku węgla\nO2 (3 – 21) %\nMetoda elektrochemiczna - CO (4,7 – 5700) mg/m3 - NO (2,5 – 850) mg/m3 - NO2 (2,5 – 200) mg/m3 - SO2 (7,85 – 330) mg/m3 - CO2 (0,5 – 18) %; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu, tlenku wegla, tlenku azotu, tlenkow azotu, dwutlenku siarki, dwutlenku wegla\nO2 (3 – 21) %\nMetoda elektrochemiczna - CO (4,7 – 5700) mg/m3 - NO (2,5 – 850) mg/m3 - NO2 (2,5 – 200) mg/m3 - SO2 (7,85 – 330) mg/m3 - CO2 (0,5 – 18) %; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen oxides, sulfur dioxide, carbon dioxide Electrochemical method - CO (4,7 – 5700) mg/m3 - NO (2,5 – 850) mg/m3 - NO2 (2,5 – 200) mg/m3 - SO2 (7,85 – 330) mg/m3 - CO2 (0,5 – 18) %; Non-dispersive infrared spectrometry method (NDIR) O2 PN-ISO 10396:2001","search_zh":"废气 O2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"O2","range":"(3 – 21) %"}]},{"_id":"6a5dc9c3f1c10c8ce825fc6c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO, NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2 ) SO2, CO2 (z obliczeń)","methodology_en":"Emission of CO, NO and NO2, NOx (NO and NO2 calculated as NO2 ) SO2, CO2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO, NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2 ) SO2, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO, NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2 ) SO2, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja CO, NO i NO2, NOx (NO i NO2 w przeliczeniu na NO2 ) SO2, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of CO, NO and NO2, NOx (NO and NO2 calculated as NO2 ) SO2, CO2 (calculated) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc6d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku siarki, dwutlenku węgla","methodology_en":"Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen oxides, sulfur dioxide, carbon dioxide","parameters":[{"name":"O2","range":"( 0,1 – 21,0) %"}],"parameters_en":[{"name":"O2","range":"( 0,1 – 21,0) %"}],"technique":"Metoda paramagnetyczna - CO2 (0,5 – 18) % - CO (3,8 – 5000) mg/m3 - SO2 (5,7 – 343) mg/m3; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (2,7 – 670) mg/m3 - NOx (4,1 – 1025) mg/m3; Metoda chemiluminescencyjna","techniques":["Metoda paramagnetyczna - CO2 (0,5 – 18) % - CO (3,8 – 5000) mg/m3 - SO2 (5,7 – 343) mg/m3","Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (2,7 – 670) mg/m3 - NOx (4,1 – 1025) mg/m3","Metoda chemiluminescencyjna"],"technique_en":"Paramagnetic method - CO2 (0,5 – 18) % - CO (3,8 – 5000) mg/m3 - SO2 (5,7 – 343) mg/m3; Non-dispersive infrared spectrometry method (NDIR) - NO (2,7 – 670) mg/m3 - NOx (4,1 – 1025) mg/m3; Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku siarki, dwutlenku węgla\nO2 ( 0,1 – 21,0) %\nMetoda paramagnetyczna - CO2 (0,5 – 18) % - CO (3,8 – 5000) mg/m3 - SO2 (5,7 – 343) mg/m3; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (2,7 – 670) mg/m3 - NOx (4,1 – 1025) mg/m3; Metoda chemiluminescencyjna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku siarki, dwutlenku węgla\nO2 ( 0,1 – 21,0) %\nMetoda paramagnetyczna - CO2 (0,5 – 18) % - CO (3,8 – 5000) mg/m3 - SO2 (5,7 – 343) mg/m3; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (2,7 – 670) mg/m3 - NOx (4,1 – 1025) mg/m3; Metoda chemiluminescencyjna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu, tlenku wegla, tlenku azotu, tlenkow azotu, dwutlenku siarki, dwutlenku wegla\nO2 ( 0,1 – 21,0) %\nMetoda paramagnetyczna - CO2 (0,5 – 18) % - CO (3,8 – 5000) mg/m3 - SO2 (5,7 – 343) mg/m3; Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (2,7 – 670) mg/m3 - NOx (4,1 – 1025) mg/m3; Metoda chemiluminescencyjna PN-ISO 10396:2001","categories":["other"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen oxides, sulfur dioxide, carbon dioxide Paramagnetic method - CO2 (0,5 – 18) % - CO (3,8 – 5000) mg/m3 - SO2 (5,7 – 343) mg/m3; Non-dispersive infrared spectrometry method (NDIR) - NO (2,7 – 670) mg/m3 - NOx (4,1 – 1025) mg/m3; Chemiluminescence method O2 PN-ISO 10396:2001","search_zh":"废气 O2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"O2","range":"( 0,1 – 21,0) %"}]},{"_id":"6a5dc9c3f1c10c8ce825fc6e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO, NO, NOx(w przeliczeniu na NO2) SO2, CO2 (z obliczeń)","methodology_en":"Emission of CO, NO, NOx(calculated as NO2) SO2, CO2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO, NO, NOx(w przeliczeniu na NO2) SO2, CO2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO, NO, NOx(w przeliczeniu na NO2) SO2, CO2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja CO, NO, NOx(w przeliczeniu na NO2) SO2, CO2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of CO, NO, NOx(calculated as NO2) SO2, CO2 (calculated) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc6f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, dwutlenku azotu, tlenków azotu","methodology_en":"Concentration of nitrogen monoxide, nitrogen dioxide, nitrogen oxides","parameters":[{"name":"NO","range":"(2,7 – 670) mg/m3"},{"name":"NOx","range":"(4,1 - 1025) mg/m3"}],"parameters_en":[{"name":"NO","range":"(2,7 – 670) mg/m3"},{"name":"NOx","range":"(4,1 - 1025) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, dwutlenku azotu, tlenków azotu\nZakres:\nNO (2,7 – 670) mg/m3\nNOx (4,1 - 1025) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, dwutlenku azotu, tlenków azotu\nZakres:\nNO (2,7 – 670) mg/m3\nNOx (4,1 - 1025) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, dwutlenku azotu, tlenkow azotu\nZakres:\nNO (2,7 – 670) mg/m3\nNOx (4,1 - 1025) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04","categories":["other"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen dioxide, nitrogen oxides Chemiluminescence method NO NOx PN-EN 14792:2017-04","search_zh":"废气 化学发光法 NO NOx PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(2,7 – 670) mg/m3"},{"name":"NOx","range":"(4,1 - 1025) mg/m3"}],"technique_zh":"化学发光法"},{"_id":"6a5dc9c3f1c10c8ce825fc70","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO, NOx (w przeliczeniu na NO2) (z obliczeń)","methodology_en":"Emission of NO, NOx (calculated as NO2) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO, NOx (w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO, NOx (w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of NO, NOx (calculated as NO2) (calculated) PN-EN 14792:2017-04","search_zh":"废气 PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc71","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(3,8 – 5000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(3,8 – 5000) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres (3,8 – 5000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres (3,8 – 5000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla\nZakres (3,8 – 5000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":139,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04","parameters_zh":[{"name":"范围","range":"(3,8 – 5000) mg/m3"}],"search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9c3f1c10c8ce825fc72","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja tlenku węgla (z obliczeń)","methodology_en":"Carbon monoxide emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) PN-EN 15058:2017-04 Gazy odlotowe Emisja tlenku wegla (z obliczen) PN-EN 15058:2017-04","categories":["environment"],"row_index":140,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide emission (calculated) PN-EN 15058:2017-04","search_zh":"废气 一氧化碳排放（由计算得出） PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc73","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"( 3 – 21,0) %"}],"parameters_en":[{"name":"Range","range":"( 3 – 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres ( 3 – 21,0) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres ( 3 – 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres ( 3 – 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":141,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-EN 14789:2017-04","parameters_zh":[{"name":"范围","range":"( 3 – 21,0) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a5dc9c3f1c10c8ce825fc74","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja tlenu (z obliczeń)","methodology_en":"Emission of oxygen (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja tlenu (z obliczeń)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja tlenu (z obliczeń) PN-EN 14789:2017-04 Gazy odlotowe Emisja tlenu (z obliczen) PN-EN 14789:2017-04","categories":["environment"],"row_index":142,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of oxygen (calculated) PN-EN 14789:2017-04","search_zh":"废气 PN-EN 14789:2017-04","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc75","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek gazów odlotowych dla oznaczania chlorowodoru","methodology_en":"Waste gas sampling for determination of hydrogen chloride","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek gazów odlotowych dla oznaczania chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek gazów odlotowych dla oznaczania chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek gazow odlotowych dla oznaczania chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":143,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Waste gas sampling for determination of hydrogen chloride PN-EN 1911:2011","search_zh":"废气 PN-EN 1911:2011","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc76","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość chlorowodoru","methodology_en":"Hydrogen chloride concentration/content","parameters":[{"name":"Zakres","range":"(1,0– 50) mg/m3"},{"name":"Zakres","range":"(0,060– 5) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(1,0– 50) mg/m3"},{"name":"Range","range":"(0,060– 5) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (1,0– 50) mg/m3\nZakres (0,060– 5) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość chlorowodoru\nZakres:\nZakres (1,0– 50) mg/m3\nZakres (0,060– 5) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (1,0– 50) mg/m3\nZakres (0,060– 5) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":144,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen chloride concentration/content Spectrophotometric method Range Range PN-EN 1911:2011","parameters_zh":[{"name":"范围","range":"(1,0– 50) mg/m3"},{"name":"范围","range":"(0,060– 5) mg w próbce"}],"search_zh":"废气 氯化氢的浓度/含量 分光光度法 范围 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc77","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja chlorowodoru (z obliczeń)","methodology_en":"Hydrogen chloride emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja chlorowodoru (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja chlorowodoru (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":145,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen chloride emission (calculated) PN-EN 1911:2011","search_zh":"废气 氯化氢排放量（计算值） PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc78","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","methodology_en":"Sampling for determination of concentrations of organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem sorbentów stałych i roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem sorbentów stałych i roztworów pochłaniających"],"technique_en":"Aspiration method using solid sorbents and absorbing solutions","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem sorbentów stałych i roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem sorbentów stałych i roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem sorbentow stalych i roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":146,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of concentrations of organic compounds Aspiration method using solid sorbents and absorbing solutions PN-Z-04008-4:1999","search_zh":"废气 有机化合物浓度测定采样 PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物浓度测定采样"},{"_id":"6a5dc9c3f1c10c8ce825fc79","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":147,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic compounds (calculated) PN-Z-04008-4:1999","search_zh":"废气 有机化合物排放量（计算值） PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc7a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":148,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a5dc9c3f1c10c8ce825fc7b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":149,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc7c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","methodology_en":"Sampling for determination of total mercury concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":150,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of total mercury concentration PN-EN 13211+AC:2006","search_zh":"废气 总汞浓度测定采样 PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a5dc9c3f1c10c8ce825fc7d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość rtęci","methodology_en":"Concentration/content of mercury","parameters":[{"name":"Zakres","range":"(0,0010 – 0,50) mg/m3"},{"name":"Zakres","range":"(0,040 –20) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0010 – 0,50) mg/m3"},{"name":"Range","range":"(0,040 –20) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość rtęci\nZakres:\nZakres (0,0010 – 0,50) mg/m3\nZakres (0,040 –20) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość rtęci\nZakres:\nZakres (0,0010 – 0,50) mg/m3\nZakres (0,040 –20) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006 Gazy odlotowe Stezenie/zawartosc rteci\nZakres:\nZakres (0,0010 – 0,50) mg/m3\nZakres (0,040 –20) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006","categories":["other"],"row_index":151,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of mercury Cold vapour atomic absorption spectrometry (CVAAS) Range Range PN-EN 13211+AC:2006","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,50) mg/m3"},{"name":"范围","range":"(0,040 –20) μg w próbce"}],"search_zh":"废气 汞的浓度/含量 冷蒸气原子吸收光谱法（CVAAS） 范围 范围 PN-EN 13211+AC:2006","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"废气","methodology_zh":"汞的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc7e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja rtęci ogólnej (z obliczeń)","methodology_en":"Total mercury emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":152,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Total mercury emission (calculated) PN-EN 13211+AC:2006","search_zh":"废气 总汞排放量（计算值） PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc7f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobór próbek do oznaczania stężenia metali (Cr, Cu, Ni, Cd, Pb, Sb, As, Co, Mn, Tl, V)","methodology_en":"Sampling for determination of metal concentrations (Cr, Cu, Ni, Cd, Pb, Sb, As, Co, Mn, Tl, V)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobór próbek do oznaczania stężenia metali (Cr, Cu, Ni, Cd, Pb, Sb, As, Co, Mn, Tl, V)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobór próbek do oznaczania stężenia metali (Cr, Cu, Ni, Cd, Pb, Sb, As, Co, Mn, Tl, V) PN-EN 14385:2005 Gazy odlotowe Pobor probek do oznaczania stezenia metali (Cr, Cu, Ni, Cd, Pb, Sb, As, Co, Mn, Tl, V) PN-EN 14385:2005","categories":["materials"],"row_index":153,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations (Cr, Cu, Ni, Cd, Pb, Sb, As, Co, Mn, Tl, V) PN-EN 14385:2005","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc80","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość metali:","methodology_en":"Metal concentrations/contents:","parameters":[{"name":"chrom","range":"(0,0080 – 0,40) mg/m3"},{"name":"Zakres","range":"(0,00050 – 0,50) mg w próbce"},{"name":"miedź","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"nikiel","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"kadm","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"ołów","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"antymon","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"arsen","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"kobalt","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"mangan","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"tal","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"},{"name":"wanad","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg w próbce"}],"parameters_en":[{"name":"chromium","range":"(0,0080 – 0,40) mg/m3"},{"name":"Range","range":"(0,00050 – 0,50) mg w próbce"},{"name":"copper","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"nickel","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"cadmium","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"lead","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"antimony","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"arsenic","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"cobalt","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"manganese","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"thallium","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"},{"name":"vanadium","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg in the sample"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość metali:\nZakres:\nchrom (0,0080 – 0,40) mg/m3\nZakres (0,00050 – 0,50) mg w próbce\nmiedź (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nnikiel (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nkadm (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nołów (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nantymon (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\narsen (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nkobalt (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nmangan (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\ntal (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nwanad (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość metali:\nZakres:\nchrom (0,0080 – 0,40) mg/m3\nZakres (0,00050 – 0,50) mg w próbce\nmiedź (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nnikiel (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nkadm (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nołów (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nantymon (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\narsen (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nkobalt (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nmangan (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\ntal (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nwanad (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2005 Gazy odlotowe Stezenie/zawartosc metali:\nZakres:\nchrom (0,0080 – 0,40) mg/m3\nZakres (0,00050 – 0,50) mg w probce\nmiedz (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nnikiel (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nkadm (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nolow (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nantymon (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\narsen (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nkobalt (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nmangan (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\ntal (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nwanad (0,0080 – 0,40) mg/m3\n(0,00050 – 0,50) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2005","categories":["materials"],"row_index":154,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Metal concentrations/contents: Inductively coupled plasma optical emission spectrometry (ICP-OES) chromium Range copper (0,00050 – 0,50) mg in the sample nickel (0,00050 – 0,50) mg in the sample cadmium (0,00050 – 0,50) mg in the sample lead (0,00050 – 0,50) mg in the sample antimony (0,00050 – 0,50) mg in the sample arsenic (0,00050 – 0,50) mg in the sample cobalt (0,00050 – 0,50) mg in the sample manganese (0,00050 – 0,50) mg in the sample thallium (0,00050 – 0,50) mg in the sample vanadium (0,00050 – 0,50) mg in the sample PN-EN 14385:2005","parameters_zh":[{"name":"铬","range":"(0,0080 – 0,40) mg/m3"},{"name":"范围","range":"(0,00050 – 0,50) mg w próbce"},{"name":"铜","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"镍","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"镉","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"铅","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"锑","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"砷","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"钴","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"锰","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"铊","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"},{"name":"钒","range":"(0,0080 – 0,40) mg/m3"},{"name":"(0,00050 – 0,50) mg/样品"}],"search_zh":"废气 金属的浓度/含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 铬 范围 铜 (0,00050 – 0,50) mg/样品 镍 (0,00050 – 0,50) mg/样品 镉 (0,00050 – 0,50) mg/样品 铅 (0,00050 – 0,50) mg/样品 锑 (0,00050 – 0,50) mg/样品 砷 (0,00050 – 0,50) mg/样品 钴 (0,00050 – 0,50) mg/样品 锰 (0,00050 – 0,50) mg/样品 铊 (0,00050 – 0,50) mg/样品 钒 (0,00050 – 0,50) mg/样品 PN-EN 14385:2005","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废气","methodology_zh":"金属的浓度/含量："},{"_id":"6a5dc9c3f1c10c8ce825fc81","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali (z obliczeń)","methodology_en":"Metal emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali (z obliczeń)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali (z obliczeń) PN-EN 14385:2005 Gazy odlotowe Emisja metali (z obliczen) PN-EN 14385:2005","categories":["materials","environment"],"row_index":155,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Metal emission (calculated) PN-EN 14385:2005","search_zh":"废气 金属排放（由计算得出） PN-EN 14385:2005","test_object_zh":"废气","methodology_zh":"金属排放（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fc82","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","methodology_en":"Sampling for the determination of sulfur dioxide concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia dwutlenku siarki PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia dwutlenku siarki PN-EN 14791:2017-04","categories":["other"],"row_index":156,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of sulfur dioxide concentration PN-EN 14791:2017-04","search_zh":"废气 用于测定二氧化硫浓度的采样 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"用于测定二氧化硫浓度的采样"},{"_id":"6a5dc9c3f1c10c8ce825fc83","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość dwutlenku siarki","methodology_en":"Concentration/content of sulphur dioxide","parameters":[{"name":"Zakres","range":"(0,22 – 26) mg/m3"},{"name":"Zakres","range":"(0,00667 – 0,667) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,22 – 26) mg/m3"},{"name":"Range","range":"(0,00667 – 0,667) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość dwutlenku siarki\nZakres:\nZakres (0,22 – 26) mg/m3\nZakres (0,00667 – 0,667) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość dwutlenku siarki\nZakres:\nZakres (0,22 – 26) mg/m3\nZakres (0,00667 – 0,667) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 14791:2017-04 Gazy odlotowe Stezenie/zawartosc dwutlenku siarki\nZakres:\nZakres (0,22 – 26) mg/m3\nZakres (0,00667 – 0,667) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 14791:2017-04","categories":["other"],"row_index":157,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of sulphur dioxide Ion chromatography with conductometric detection (IC-CD) Range Range PN-EN 14791:2017-04","parameters_zh":[{"name":"范围","range":"(0,22 – 26) mg/m3"},{"name":"范围","range":"(0,00667 – 0,667) mg w próbce"}],"search_zh":"废气 离子色谱-电导检测法（IC-CD） 范围 范围 PN-EN 14791:2017-04","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc84","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2 (z obliczeń)","methodology_en":"SO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":158,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 emission (calculated) PN-EN 14791:2017-04","search_zh":"废气 SO2 排放量（计算值） PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc85","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","methodology_en":"Sampling for determination of hydrogen fluoride concentration","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"technique_en":"Aspiration method using absorbing solutions","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych ISO 15713:2006","categories":["other"],"row_index":159,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration Aspiration method using absorbing solutions ISO 15713:2006","search_zh":"废气 氟化氢浓度测定采样 采用吸收液的抽气法 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"氟化氢浓度测定采样","technique_zh":"采用吸收液的抽气法"},{"_id":"6a5dc9c3f1c10c8ce825fc86","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość fluorowodoru","methodology_en":"Hydrogen fluoride concentration/content","parameters":[{"name":"Zakres","range":"(0,17 – 18,5) mg/m3"},{"name":"Zakres","range":"(0,01 - 1) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,17 – 18,5) mg/m3"},{"name":"Range","range":"(0,01 - 1) mg w próbce"}],"technique":"Metoda z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda z zastosowaniem elektrody jonoselektywnej"],"technique_en":"Method using an ion-selective electrode","computed":[],"computed_en":[],"activity":"Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,17 – 18,5) mg/m3\nZakres (0,01 - 1) mg w próbce\nMetoda z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,17 – 18,5) mg/m3\nZakres (0,01 - 1) mg w próbce\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 Gazy odlotowe Stezenie/zawartosc fluorowodoru\nZakres:\nZakres (0,17 – 18,5) mg/m3\nZakres (0,01 - 1) mg w probce\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006","categories":["other"],"row_index":160,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen fluoride concentration/content Method using an ion-selective electrode Range Range ISO 15713:2006","parameters_zh":[{"name":"范围","range":"(0,17 – 18,5) mg/m3"},{"name":"范围","range":"(0,01 - 1) mg w próbce"}],"search_zh":"废气 氟化氢的浓度/含量 离子选择电极法 范围 范围 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"氟化氢的浓度/含量","technique_zh":"离子选择电极法"},{"_id":"6a5dc9c3f1c10c8ce825fc87","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HF (z obliczeń)","methodology_en":"HF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":161,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HF emission (calculated) ISO 15713:2006","search_zh":"废气 HF 排放量（计算值） ISO 15713:2006","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc88","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(1,6 – 1000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,6 – 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowojonizacyjnej (FID)"],"technique_en":"Continuous flame ionization detection method (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,6 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (1,6 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowojonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (1,6 – 1000) mg/m3\nMetoda ciaglej detekcji plomieniowojonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":162,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05","parameters_zh":[{"name":"范围","range":"(1,6 – 1000) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a5dc9c3f1c10c8ce825fc89","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":163,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5dc9c3f1c10c8ce825fc8a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość fenolu","methodology_en":"Phenol concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość fenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I35 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość fenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc fenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I35 wydanie 4 z 2016-10-03","categories":["other"],"row_index":164,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Phenol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 苯酚的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc8b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość 2-chlorofenolu","methodology_en":"Concentration/content of 2-chlorophenol","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość 2-chlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I35 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość 2-chlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc 2-chlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I35 wydanie 4 z 2016-10-03","categories":["other"],"row_index":165,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of 2-chlorophenol Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc8c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość 2.4-dichlorofenolu","methodology_en":"Concentration/content of 2.4-dichlorophenol","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość 2.4-dichlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I35 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość 2.4-dichlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc 2.4-dichlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I35 wydanie 4 z 2016-10-03","categories":["other"],"row_index":166,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of 2.4-dichlorophenol Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc8d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość 4-chlorofenolu","methodology_en":"Concentration/content of 4-chlorophenol","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość 4-chlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I35 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość 4-chlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc 4-chlorofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I35 wydanie 4 z 2016-10-03","categories":["other"],"row_index":167,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of 4-chlorophenol Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc8e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość 4-chloro-2-metylofenolu","methodology_en":"Concentration/content of 4-chloro-2-methylphenol","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość 4-chloro-2-metylofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I35 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość 4-chloro-2-metylofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc 4-chloro-2-metylofenolu\nZakres:\nZakres (0,10 – 20) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I35 wydanie 4 z 2016-10-03","categories":["other"],"row_index":168,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of 4-chloro-2-methylphenol Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc8f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość sumy chlorofenoli (z obliczeń)","methodology_en":"Concentration/content of the sum of chlorophenols (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/zawartość sumy chlorofenoli (z obliczeń)","reference":"PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I35 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość sumy chlorofenoli (z obliczeń) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc sumy chlorofenoli (z obliczen) PRB.SPP.8I35 wydanie 4 z 2016-10-03","categories":["other"],"row_index":169,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of the sum of chlorophenols (calculated) PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","search_zh":"废气 PRB.ŚPP.8I35 wydanie 4 z 2016-10-03","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc90","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość dimetyloaminy","methodology_en":"Concentration/content of dimethylamine","parameters":[{"name":"Zakres","range":"(0,33 – 50) mg/m3"},{"name":"Zakres","range":"(3,0 – 500) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,33 – 50) mg/m3"},{"name":"Range","range":"(3,0 – 500) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość dimetyloaminy\nZakres:\nZakres (0,33 – 50) mg/m3\nZakres (3,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I46 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I46 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość dimetyloaminy\nZakres:\nZakres (0,33 – 50) mg/m3\nZakres (3,0 – 500) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I46 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc dimetyloaminy\nZakres:\nZakres (0,33 – 50) mg/m3\nZakres (3,0 – 500) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I46 wydanie 4 z 2016-10-03","categories":["other"],"row_index":170,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of dimethylamine Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I46 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,33 – 50) mg/m3"},{"name":"范围","range":"(3,0 – 500) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I46 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc91","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość n-butanolu","methodology_en":"n-Butanol concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość n-butanolu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość n-butanolu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04023-02:1989 Gazy odlotowe Stezenie/zawartosc n-butanolu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04023-02:1989","categories":["other"],"row_index":171,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases n-Butanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04023-02:1989","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04023-02:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc92","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość izopropanolu","methodology_en":"Isopropanol concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość izopropanolu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość izopropanolu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04023-02:1989 Gazy odlotowe Stezenie/zawartosc izopropanolu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04023-02:1989","categories":["other"],"row_index":172,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Isopropanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04023-02:1989","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04023-02:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc93","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość benzenu","methodology_en":"Benzene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość benzenu\nZakres:\nZakres (0,10 – 50) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005 z wyłączeniem punktu 8","norm_bases":["PN-Z-04016-10:2005 z wyłączeniem punktu 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość benzenu\nZakres:\nZakres (0,10 – 50) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 z wyłączeniem punktu 8 Gazy odlotowe Stezenie/zawartosc benzenu\nZakres:\nZakres (0,10 – 50) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005 z wylaczeniem punktu 8","categories":["other"],"row_index":173,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Benzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005 z wyłączeniem punktu 8","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005 z wyłączeniem punktu 8","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"苯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc94","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość epoksyetanu","methodology_en":"Ethylene oxide concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość epoksyetanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04300:2002 z wyłączeniem punktu 8","norm_bases":["PN-Z-04300:2002 z wyłączeniem punktu 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość epoksyetanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04300:2002 z wyłączeniem punktu 8 Gazy odlotowe Stezenie/zawartosc epoksyetanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04300:2002 z wylaczeniem punktu 8","categories":["other"],"row_index":174,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ethylene oxide concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04300:2002 z wyłączeniem punktu 8","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 环氧乙烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04300:2002 z wyłączeniem punktu 8","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"环氧乙烷的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc95","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość 1,2-epoksypropanu","methodology_en":"Concentration/content of 1,2-epoxypropane","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość 1,2-epoksypropanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04286:2002 z wyłączeniem punktu 8","norm_bases":["PN-Z-04286:2002 z wyłączeniem punktu 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość 1,2-epoksypropanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04286:2002 z wyłączeniem punktu 8 Gazy odlotowe Stezenie/zawartosc 1,2-epoksypropanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04286:2002 z wylaczeniem punktu 8","categories":["other"],"row_index":175,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of 1,2-epoxypropane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04286:2002 z wyłączeniem punktu 8","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04286:2002 z wyłączeniem punktu 8","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc96","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość formaldehydu","methodology_en":"Formaldehyde concentration/content","parameters":[{"name":"Zakres","range":"(0,8 – 25) mg/m3"},{"name":"Zakres","range":"(8 –250) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,8 – 25) mg/m3"},{"name":"Range","range":"(8 –250) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,8 – 25) mg/m3\nZakres (8 –250) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04045-08:1990 z wyłączeniem punktu 7","norm_bases":["PN-Z-04045-08:1990 z wyłączeniem punktu 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,8 – 25) mg/m3\nZakres (8 –250) μg w próbce\nMetoda spektrofotometryczna PN-Z-04045-08:1990 z wyłączeniem punktu 7 Gazy odlotowe Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,8 – 25) mg/m3\nZakres (8 –250) μg w probce\nMetoda spektrofotometryczna PN-Z-04045-08:1990 z wylaczeniem punktu 7","categories":["other"],"row_index":176,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Formaldehyde concentration/content Spectrophotometric method Range Range PN-Z-04045-08:1990 z wyłączeniem punktu 7","parameters_zh":[{"name":"范围","range":"(0,8 – 25) mg/m3"},{"name":"范围","range":"(8 –250) μg w próbce"}],"search_zh":"废气 甲醛浓度/含量 分光光度法 范围 范围 PN-Z-04045-08:1990 z wyłączeniem punktu 7","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"甲醛浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc97","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie /zawartość 1,2-dichloroetanu","methodology_en":"Concentration / content of 1,2-dichloroethane","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie /zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04237:1994","norm_bases":["PN-Z-04237:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie /zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04237:1994 Gazy odlotowe Stezenie /zawartosc 1,2-dichloroetanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04237:1994","categories":["other"],"row_index":177,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of 1,2-dichloroethane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04237:1994","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04237:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc98","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość sumy chlorobenzenów (z obliczeń)","methodology_en":"Concentration/content of the sum of chlorobenzenes (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/zawartość sumy chlorobenzenów (z obliczeń)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość sumy chlorobenzenów (z obliczeń) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc sumy chlorobenzenow (z obliczen) PN-Z-04016-10:2005","categories":["other"],"row_index":178,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of the sum of chlorobenzenes (calculated) PN-Z-04016-10:2005","search_zh":"废气 PN-Z-04016-10:2005","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc99","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie /zawartość chlorobenzenu","methodology_en":"Concentration / content of chlorobenzene","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1 000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1 000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie /zawartość chlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1 000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie /zawartość chlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1 000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie /zawartosc chlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1 000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":179,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of chlorobenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1 000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc9a","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie /zawartość 1,2-dichlorobenzenu","methodology_en":"Concentration / content of 1,2-dichlorobenzene","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1 000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1 000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie /zawartość 1,2-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1 000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie /zawartość 1,2-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1 000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie /zawartosc 1,2-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1 000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":180,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of 1,2-dichlorobenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1 000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc9b","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie /zawartość 1,3-dichlorobenzenu","methodology_en":"Concentration / content of 1,3-dichlorobenzene","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie /zawartość 1,3-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie /zawartość 1,3-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie /zawartosc 1,3-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":181,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of 1,3-dichlorobenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc9c","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie /zawartość 1,4-dichlorobenzenu","methodology_en":"Concentration / content of 1,4-dichlorobenzene","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie /zawartość 1,4-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie /zawartość 1,4-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie /zawartosc 1,4-dichlorobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":182,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of 1,4-dichlorobenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc9d","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość sumy dwuchlorobenzenów (z obliczeń)","methodology_en":"Concentration/content of the sum of dichlorobenzenes (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/zawartość sumy dwuchlorobenzenów (z obliczeń)","reference":"PN-EN 13649:2005 PRB.ŚPP.8I01 Wydanie 1 z dn. 14.05.2024","norm_bases":["PN-EN 13649:2005 PRB.ŚPP.8I01 Wydanie 1 z dn. 14.05.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość sumy dwuchlorobenzenów (z obliczeń) PN-EN 13649:2005 PRB.ŚPP.8I01 Wydanie 1 z dn. 14.05.2024 Gazy odlotowe Stezenie/zawartosc sumy dwuchlorobenzenow (z obliczen) PN-EN 13649:2005 PRB.SPP.8I01 Wydanie 1 z dn. 14.05.2024","categories":["other"],"row_index":183,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of the sum of dichlorobenzenes (calculated) PN-EN 13649:2005 PRB.ŚPP.8I01 Wydanie 1 z dn. 14.05.2024","search_zh":"废气 PN-EN 13649:2005 PRB.ŚPP.8I01 Wydanie 1 z dn. 14.05.2024","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fc9e","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość etylobenzenu","methodology_en":"Ethylbenzene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość etylobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość etylobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc etylobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":184,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ethylbenzene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 乙苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙苯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fc9f","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość m-ksylenu","methodology_en":"m-Xylene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość m-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość m-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc m-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":185,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases m-Xylene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fca0","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość p-ksylenu","methodology_en":"p-Xylene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość p-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość p-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc p-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":186,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases p-Xylene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fca1","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość o-ksylenu","methodology_en":"o-Xylene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość o-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość o-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc o-ksylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":187,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases o-Xylene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fca2","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość kumenu","methodology_en":"Concentration/content of cumene","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość kumenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość kumenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc kumenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":188,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of cumene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 异丙苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"异丙苯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fca3","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość propylobenzenu","methodology_en":"Concentration/content of propylbenzene","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość propylobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość propylobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc propylobenzenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":189,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of propylbenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fca4","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość mezytylenu","methodology_en":"Mesitylene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość mezytylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość mezytylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc mezytylenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":190,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Mesitylene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fca5","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość pseudokumenu","methodology_en":"Pseudocumene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość pseudokumenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość pseudokumenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc pseudokumenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":191,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Pseudocumene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fca6","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość toluenu","methodology_en":"Toluene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość toluenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość toluenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc toluenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["other"],"row_index":192,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Toluene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-10:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 甲苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"甲苯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fca7","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość sumy węglowodorów aromatycznych (z obliczeń)","methodology_en":"Concentration/content of the sum of aromatic hydrocarbons (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/zawartość sumy węglowodorów aromatycznych (z obliczeń)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość sumy węglowodorów aromatycznych (z obliczeń) PN-Z-04016-10:2005 Gazy odlotowe Stezenie/zawartosc sumy weglowodorow aromatycznych (z obliczen) PN-Z-04016-10:2005","categories":["other"],"row_index":193,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of the sum of aromatic hydrocarbons (calculated) PN-Z-04016-10:2005","search_zh":"废气 PN-Z-04016-10:2005","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fca8","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość pentanu","methodology_en":"Pentane concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość pentanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość pentanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc pentanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":194,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Pentane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 戊烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"戊烷的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fca9","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość heksanu","methodology_en":"Hexane concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość heksanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość heksanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc heksanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":195,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hexane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 正己烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"正己烷的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcaa","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość heptanu","methodology_en":"Heptane concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość heptanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość heptanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc heptanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":196,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Heptane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 正庚烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"正庚烷的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcab","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość oktanu","methodology_en":"Octane concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość oktanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość oktanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc oktanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":197,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Octane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 辛烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"辛烷的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcac","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość nonanu","methodology_en":"Nonane concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość nonanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość nonanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc nonanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":198,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Nonane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcad","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość dekanu","methodology_en":"Concentration/content of decane","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość dekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość dekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc dekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":199,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of decane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcae","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość undekanu","methodology_en":"Undecane concentration/content","parameters":[{"name":"Zakres","range":"(0,047 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,047 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość undekanu\nZakres:\nZakres (0,047 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość undekanu\nZakres:\nZakres (0,047 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc undekanu\nZakres:\nZakres (0,047 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":200,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Undecane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,047 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcaf","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość dodekanu","methodology_en":"Concentration/content of dodecane","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość dodekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość dodekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc dodekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":201,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of dodecane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcb0","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość tridekanu","methodology_en":"Tridecane concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość tridekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość tridekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc tridekanu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":202,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Tridecane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcb1","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość heksadekanu","methodology_en":"Hexadecane concentration/content","parameters":[{"name":"Zakres","range":"(0,16 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,16 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość heksadekanu\nZakres:\nZakres (0,16 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość heksadekanu\nZakres:\nZakres (0,16 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc heksadekanu\nZakres:\nZakres (0,16 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["other"],"row_index":203,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hexadecane concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","parameters_zh":[{"name":"范围","range":"(0,16 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcb2","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość sumy węglowodorów alifatycznych (z obliczeń)","methodology_en":"Concentration/content of the sum of aliphatic hydrocarbons (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie/zawartość sumy węglowodorów alifatycznych (z obliczeń)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość sumy węglowodorów alifatycznych (z obliczeń) PN-Z-04318:2005 Gazy odlotowe Stezenie/zawartosc sumy weglowodorow alifatycznych (z obliczen) PN-Z-04318:2005","categories":["other"],"row_index":204,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of the sum of aliphatic hydrocarbons (calculated) PN-Z-04318:2005","search_zh":"废气 PN-Z-04318:2005","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcb3","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość 1,2-dichloropropanu","methodology_en":"Concentration/content of 1,2-dichloropropane","parameters":[{"name":"Zakres","range":"(0,12 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,12 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość 1,2-dichloropropanu\nZakres:\nZakres (0,12 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PRB.ŚPP.8I74 wydanie 4 z 2016-10-03","norm_bases":["PRB.ŚPP.8I74 wydanie 4 z 2016-10-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość 1,2-dichloropropanu\nZakres:\nZakres (0,12 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PRB.ŚPP.8I74 wydanie 4 z 2016-10-03 Gazy odlotowe Stezenie/zawartosc 1,2-dichloropropanu\nZakres:\nZakres (0,12 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PRB.SPP.8I74 wydanie 4 z 2016-10-03","categories":["other"],"row_index":205,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of 1,2-dichloropropane Gas chromatography with flame ionization detection (GC-FID) Range Range PRB.ŚPP.8I74 wydanie 4 z 2016-10-03","parameters_zh":[{"name":"范围","range":"(0,12 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PRB.ŚPP.8I74 wydanie 4 z 2016-10-03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcb4","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość metakrylanu metylu","methodology_en":"Methyl methacrylate concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość metakrylanu metylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-11:1994","norm_bases":["PN-Z-04113-11:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość metakrylanu metylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-11:1994 Gazy odlotowe Stezenie/zawartosc metakrylanu metylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-11:1994","categories":["other"],"row_index":206,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Methyl methacrylate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-11:1994","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 甲基丙烯酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-11:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"甲基丙烯酸甲酯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcb5","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość metakrylanu butylu","methodology_en":"Concentration/content of butyl methacrylate","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość metakrylanu butylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-11:1994","norm_bases":["PN-Z-04113-11:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość metakrylanu butylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-11:1994 Gazy odlotowe Stezenie/zawartosc metakrylanu butylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-11:1994","categories":["other"],"row_index":207,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of butyl methacrylate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-11:1994","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-11:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcb6","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość akrylanu metylu","methodology_en":"Methyl acrylate concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość akrylanu metylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-11:1994","norm_bases":["PN-Z-04113-11:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość akrylanu metylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-11:1994 Gazy odlotowe Stezenie/zawartosc akrylanu metylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-11:1994","categories":["other"],"row_index":208,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Methyl acrylate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-11:1994","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 丙烯酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-11:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"丙烯酸甲酯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcb7","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość akrylanu etylu","methodology_en":"Concentration/content of ethyl acrylate","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość akrylanu etylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-11:1994","norm_bases":["PN-Z-04113-11:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość akrylanu etylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-11:1994 Gazy odlotowe Stezenie/zawartosc akrylanu etylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-11:1994","categories":["other"],"row_index":209,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of ethyl acrylate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-11:1994","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-11:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcb8","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość styrenu","methodology_en":"Styrene concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość styrenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-11:1994","norm_bases":["PN-Z-04113-11:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość styrenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-11:1994 Gazy odlotowe Stezenie/zawartosc styrenu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-11:1994","categories":["other"],"row_index":210,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Styrene concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-11:1994","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 苯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-11:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"苯乙烯的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcb9","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość akrylonitrylu","methodology_en":"Acrylonitrile concentration/content","parameters":[{"name":"Zakres","range":"(0,10 – 100) mg/m3"},{"name":"Zakres","range":"(1,0 – 1000) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) mg/m3"},{"name":"Range","range":"(1,0 – 1000) μg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość akrylonitrylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-11:1994","norm_bases":["PN-Z-04113-11:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość akrylonitrylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-11:1994 Gazy odlotowe Stezenie/zawartosc akrylonitrylu\nZakres:\nZakres (0,10 – 100) mg/m3\nZakres (1,0 – 1000) μg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-11:1994","categories":["other"],"row_index":211,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Acrylonitrile concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04113-11:1994","parameters_zh":[{"name":"范围","range":"(0,10 – 100) mg/m3"},{"name":"范围","range":"(1,0 – 1000) μg w próbce"}],"search_zh":"废气 丙烯腈的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04113-11:1994","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"丙烯腈的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcba","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość 1,4-dioksanu","methodology_en":"Concentration/content of 1,4-dioxane","parameters":[{"name":"Zakres","range":"(0,10 – 120) mg/m3"},{"name":"Zakres","range":"(0,0010 – 1,20) mg w"},{"name":"próbce"}],"parameters_en":[{"name":"Range","range":"(0,10 – 120) mg/m3"},{"name":"Range","range":"(0,0010 – 1,20) mg w"},{"name":"sample"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość 1,4-dioksanu\nZakres:\nZakres (0,10 – 120) mg/m3\nZakres (0,0010 – 1,20) mg w\npróbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1 (59)","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1 (59)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość 1,4-dioksanu\nZakres:\nZakres (0,10 – 120) mg/m3\nZakres (0,0010 – 1,20) mg w\npróbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1 (59) Gazy odlotowe Stezenie/zawartosc 1,4-dioksanu\nZakres:\nZakres (0,10 – 120) mg/m3\nZakres (0,0010 – 1,20) mg w\nprobce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2009, nr 1 (59)","categories":["environment"],"row_index":212,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of 1,4-dioxane Gas chromatography with flame ionization detection (GC-FID) Range Range sample Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1 (59)","parameters_zh":[{"name":"范围","range":"(0,10 – 120) mg/m3"},{"name":"范围","range":"(0,0010 – 1,20) mg w"},{"name":"样品中"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 样品中 Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1 (59)","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcbb","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość glikolu etylenowego","methodology_en":"Ethylene glycol concentration/content","parameters":[{"name":"Zakres","range":"(2,5 – 160) mg/m3"},{"name":"Zakres","range":"(0,025 – 1,6) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(2,5 – 160) mg/m3"},{"name":"Range","range":"(0,025 – 1,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (2,5 – 160) mg/m3\nZakres (0,025 – 1,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (2,5 – 160) mg/m3\nZakres (0,025 – 1,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17 Gazy odlotowe Stezenie/zawartosc glikolu etylenowego\nZakres:\nZakres (2,5 – 160) mg/m3\nZakres (0,025 – 1,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 1997, nr 17","categories":["environment"],"row_index":213,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ethylene glycol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17","parameters_zh":[{"name":"范围","range":"(2,5 – 160) mg/m3"},{"name":"范围","range":"(0,025 – 1,6) mg w próbce"}],"search_zh":"废气 乙二醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","methodology_zh":"乙二醇的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcbc","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość kwasu siarkowego","methodology_en":"Sulfuric acid concentration/content","parameters":[{"name":"Zakres","range":"(0,1 – 1) mg/m3"},{"name":"Zakres","range":"(0,20 – 2,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,1 – 1) mg/m3"},{"name":"Range","range":"(0,20 – 2,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,1 – 1) mg/m3\nZakres (0,20 – 2,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024","norm_bases":["PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,1 – 1) mg/m3\nZakres (0,20 – 2,0) mg w próbce\nMetoda spektrofotometryczna PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024 Gazy odlotowe Stezenie/zawartosc kwasu siarkowego\nZakres:\nZakres (0,1 – 1) mg/m3\nZakres (0,20 – 2,0) mg w probce\nMetoda spektrofotometryczna PRB.SPP.8I98, wydanie 2 z dnia 30.09.2024","categories":["other"],"row_index":214,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sulfuric acid concentration/content Spectrophotometric method Range Range PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024","parameters_zh":[{"name":"范围","range":"(0,1 – 1) mg/m3"},{"name":"范围","range":"(0,20 – 2,0) mg w próbce"}],"search_zh":"废气 硫酸的浓度/含量 分光光度法 范围 范围 PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"硫酸的浓度/含量"},{"_id":"6a5dc9c3f1c10c8ce825fcbd","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja kwasu siarkowego (z obliczeń)","methodology_en":"Sulfuric acid emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja kwasu siarkowego (z obliczeń)","reference":"PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024","norm_bases":["PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja kwasu siarkowego (z obliczeń) PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024 Gazy odlotowe Emisja kwasu siarkowego (z obliczen) PRB.SPP.8I98, wydanie 2 z dnia 30.09.2024","categories":["environment"],"row_index":215,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sulfuric acid emission (calculated) PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024","search_zh":"废气 硫酸排放（由计算得出） PRB.ŚPP.8I98, wydanie 2 z dnia 30.09.2024","test_object_zh":"废气","methodology_zh":"硫酸排放（由计算得出）"},{"_id":"6a5dc9c3f1c10c8ce825fcbe","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość izocyjanianów – MDI","methodology_en":"Concentration/content of isocyanates – MDI","parameters":[{"name":"Zakres","range":"(0,0052 – 0,208) mg/m3"},{"name":"Zakres","range":"(0,625 – 25) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0052 – 0,208) mg/m3"},{"name":"Range","range":"(0,625 – 25) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość izocyjanianów – MDI\nZakres:\nZakres (0,0052 – 0,208) mg/m3\nZakres (0,625 – 25) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04131-02:1981","norm_bases":["PN-Z-04131-02:1981"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość izocyjanianów – MDI\nZakres:\nZakres (0,0052 – 0,208) mg/m3\nZakres (0,625 – 25) μg w próbce\nMetoda spektrofotometryczna PN-Z-04131-02:1981 Gazy odlotowe Stezenie/zawartosc izocyjanianow – MDI\nZakres:\nZakres (0,0052 – 0,208) mg/m3\nZakres (0,625 – 25) μg w probce\nMetoda spektrofotometryczna PN-Z-04131-02:1981","categories":["other"],"row_index":216,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of isocyanates – MDI Spectrophotometric method Range Range PN-Z-04131-02:1981","parameters_zh":[{"name":"范围","range":"(0,0052 – 0,208) mg/m3"},{"name":"范围","range":"(0,625 – 25) μg w próbce"}],"search_zh":"废气 分光光度法 范围 范围 PN-Z-04131-02:1981","technique_zh":"分光光度法","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcbf","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość izocyjanianów – TDI","methodology_en":"Concentration/content of isocyanates – TDI","parameters":[{"name":"Zakres","range":"(0,0047 – 0,375) mg/m3"},{"name":"Zakres","range":"(0,56 – 45) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0047 – 0,375) mg/m3"},{"name":"Range","range":"(0,56 – 45) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość izocyjanianów – TDI\nZakres:\nZakres (0,0047 – 0,375) mg/m3\nZakres (0,56 – 45) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04131-01:1981","norm_bases":["PN-Z-04131-01:1981"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość izocyjanianów – TDI\nZakres:\nZakres (0,0047 – 0,375) mg/m3\nZakres (0,56 – 45) μg w próbce\nMetoda spektrofotometryczna PN-Z-04131-01:1981 Gazy odlotowe Stezenie/zawartosc izocyjanianow – TDI\nZakres:\nZakres (0,0047 – 0,375) mg/m3\nZakres (0,56 – 45) μg w probce\nMetoda spektrofotometryczna PN-Z-04131-01:1981","categories":["other"],"row_index":217,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration/content of isocyanates – TDI Spectrophotometric method Range Range PN-Z-04131-01:1981","parameters_zh":[{"name":"范围","range":"(0,0047 – 0,375) mg/m3"},{"name":"范围","range":"(0,56 – 45) μg w próbce"}],"search_zh":"废气 分光光度法 范围 范围 PN-Z-04131-01:1981","technique_zh":"分光光度法","test_object_zh":"废气"},{"_id":"6a5dc9c3f1c10c8ce825fcc0","lab_id":"69ad52a3de79e566650fb4b2","country":"PL","accr_number":"AB 935","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie/zawartość chloru","methodology_en":"Chlorine concentration/content","parameters":[{"name":"Zakres","range":"(0,025 – 1) mg/m3"},{"name":"Zakres","range":"(0,25 – 10) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,025 – 1) mg/m3"},{"name":"Range","range":"(0,25 – 10) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,025 – 1) mg/m3\nZakres (0,25 – 10) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04037-03:1975","norm_bases":["PN-Z-04037-03:1975"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie/zawartość chloru\nZakres:\nZakres (0,025 – 1) mg/m3\nZakres (0,25 – 10) μg w próbce\nMetoda spektrofotometryczna PN-Z-04037-03:1975 Gazy odlotowe Stezenie/zawartosc chloru\nZakres:\nZakres (0,025 – 1) mg/m3\nZakres (0,25 – 10) μg w probce\nMetoda spektrofotometryczna PN-Z-04037-03:1975","categories":["other"],"row_index":218,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Chlorine concentration/content Spectrophotometric method Range Range PN-Z-04037-03:1975","parameters_zh":[{"name":"范围","range":"(0,025 – 1) mg/m3"},{"name":"范围","range":"(0,25 – 10) μg w próbce"}],"search_zh":"废气 氯的浓度/含量 分光光度法 范围 范围 PN-Z-04037-03:1975","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氯的浓度/含量"}],"has_pdf":true}