{"lab":{"_id":"69ad52a3de79e566650fb4a6","accr_number":"AB 927","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ CHEMICZNYCH I ŚRODOWISKOWYCH, ul. Elektryczna 5, 07-401 Ostrołęka","categories":["petro","environment","water","materials","construction"],"city":"Ostrołęka","imported_at":"2026-03-08T10:42:43.265Z","methods_count":62,"name":"ENERGA ELEKTROWNIE OSTROŁĘKA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_927.pdf"],"scope_summary":"","search_text":"energa elektrownie ostrołęka s.a. laboratorium badań chemicznych i środowiskowych, ul. elektryczna 5, 07-401 ostrołęka other environment pharma electronics metrology materials petro construction water","status":"active","updated_at":"2026-03-08T14:51:49.158Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:40:04.457Z","email_confidence":"high","email_mx":true,"email_source":"https://energaostroleka.pl/kontakt/dane-teleadresowe/","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie, mikroklimat, wydatek energetyczny)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate, energy expenditure)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"C/5, C/10, C/32","pl":"Badania chemiczne materiałów budowlanych, paliw, odpadów","en":"Chemical tests of chemical products, building materials, fuels, waste"},{"codes":"C/10/P, C/28/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek paliw, wody, ścieków","en":"Chemical tests and sampling of fuels, water, sewage"},{"codes":"N/10/P, N/28/P, N/30/P","pl":"Badanie właściwości fizycznych i pobieranie próbek paliw, wody, ścieków","en":"Tests of physical properties and sampling of fuels, water, sewage"},{"codes":"N/5, N/10, N/32","pl":"Badanie właściwości fizycznych materiałów budowlanych, paliw, odpadów","en":"Tests of physical properties of chemical products, building materials, fuels, waste"}],"issue":{"no":"20","date":"29.05.2026"},"parse_date":"2026-08-18T01:40:04.457Z","parse_source":"agent-claude-code","map_coord":[53.104379,21.61538],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAŃ CHEMICZNYCH I ŚRODOWISKOWYCH","address":"ul. Elektryczna 5","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/e862e53eb020c74a71519da471a0133c/AB%20927.pdf","has_en":true,"category_counts":{"petro":27,"environment":27,"water":8,"materials":5,"construction":4},"category_scores":{"petro":10.27,"environment":10.27,"water":0.9,"materials":0.35,"construction":0.23},"has_zh":true},"methods":[{"_id":"6a83b7f4af14b9c0e7b210f3","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 − 136) dB strategia I"},{"name":"Zakres","range":"(45 − 140) dB strategia II i III"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(55 − 140) dB strategia I i II"},{"name":"Zakres","range":"(100 − 143) dB strategia III"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A\nZakres:\nZakres (40 − 136) dB strategia I\nZakres (45 − 140) dB strategia II i III\nSzczytowy poziom dźwięku C\nZakres (55 − 140) dB strategia I i II\nZakres (100 − 143) dB strategia III\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9612:2025-11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2025-11","PN-N-01307:1994"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A\nZakres:\nZakres (40 − 136) dB strategia I\nZakres (45 − 140) dB strategia II i III\nSzczytowy poziom dźwięku C\nZakres (55 − 140) dB strategia I i II\nZakres (100 − 143) dB strategia III\nMetoda pomiarowa bezpośrednia PN-EN ISO 9612:2025-11 | PN-N-01307:1994 Srodowisko pracy − halas Rownowazny poziom dzwieku A, Maksymalny poziom dzwieku A\nZakres:\nZakres (40 − 136) dB strategia I\nZakres (45 − 140) dB strategia II i III\nSzczytowy poziom dzwieku C\nZakres (55 − 140) dB strategia I i II\nZakres (100 − 143) dB strategia III\nMetoda pomiarowa bezposrednia PN-EN ISO 9612:2025-11 | PN-N-01307:1994","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level, A-weighted maximum sound level","parameters_en":[{"name":"Range","range":"(40 − 136) dB strategia I"},{"name":"Range","range":"(45 − 140) dB strategia II i III"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(55 − 140) dB strategia I i II"},{"name":"Range","range":"(100 − 143) dB strategia III"}],"search_en":"Workplace environment − noise A-weighted equivalent sound level, A-weighted maximum sound level Direct measurement method Range Range C-weighted peak sound pressure level Range Range PN-EN ISO 9612:2025-11 | PN-N-01307:1994","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","parameters_zh":[{"name":"范围","range":"(40 − 136) dB strategia I"},{"name":"范围","range":"(45 − 140) dB strategia II i III"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(55 − 140) dB strategia I i II"},{"name":"范围","range":"(100 − 143) dB strategia III"}],"search_zh":"工作环境 − 噪声 直接测量法 范围 范围 C 计权峰值声级 范围 范围 PN-EN ISO 9612:2025-11 | PN-N-01307:1994","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a83b7f4af14b9c0e7b210f4","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-EN ISO 9612:2025-11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2025-11","PN-N-01307:1994"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-EN ISO 9612:2025-11 | PN-N-01307:1994 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-EN ISO 9612:2025-11 | PN-N-01307:1994","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level normalised to: − an 8-hour working day − an average weekly working time (calculated)","search_en":"Workplace environment − noise Noise exposure level normalised to: − an 8-hour working day − an average weekly working time (calculated) PN-EN ISO 9612:2025-11 | PN-N-01307:1994","test_object_en":"Workplace environment − noise","search_zh":"工作环境 − 噪声 PN-EN ISO 9612:2025-11 | PN-N-01307:1994","test_object_zh":"工作环境 − 噪声"},{"_id":"6a83b7f4af14b9c0e7b210f5","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − hałas infradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową G","parameters":[{"name":"Zakres","range":"(24 − 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową G\nZakres (24 − 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01338:2010","norm_bases":["PN-Z-01338:2010"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas infradźwiękowy Równoważny poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową G\nZakres (24 − 137) dB\nMetoda pomiarowa bezpośrednia PN-Z-01338:2010 Srodowisko pracy − halas infradzwiekowy Rownowazny poziom cisnienia akustycznego skorygowany charakterystyka czestotliwosciowa G\nZakres (24 − 137) dB\nMetoda pomiarowa bezposrednia PN-Z-01338:2010","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"G-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24 − 137) dB"}],"search_en":"Workplace environment − infrasonic noise G-weighted equivalent sound pressure level Direct measurement method Range PN-Z-01338:2010","technique_en":"Direct measurement method","test_object_en":"Workplace environment − infrasonic noise","parameters_zh":[{"name":"范围","range":"(24 − 137) dB"}],"search_zh":"工作环境 － 次声噪声 G 计权等效声压级 直接测量法 范围 PN-Z-01338:2010","technique_zh":"直接测量法","methodology_zh":"G 计权等效声压级","test_object_zh":"工作环境 － 次声噪声"},{"_id":"6a83b7f4af14b9c0e7b210f6","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − hałas infradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową G odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową G odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01338:2010","norm_bases":["PN-Z-01338:2010"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas infradźwiękowy Równoważny poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową G odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01338:2010 Srodowisko pracy − halas infradzwiekowy Rownowazny poziom cisnienia akustycznego skorygowany charakterystyka czestotliwosciowa G odniesiony do: − 8 godzinnego dobowego wymiaru czasu pracy − przecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01338:2010","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"G-weighted equivalent sound pressure level referred to: − the 8-hour daily working time − the average weekly working time (calculated)","search_en":"Workplace environment − infrasonic noise G-weighted equivalent sound pressure level referred to: − the 8-hour daily working time − the average weekly working time (calculated) PN-Z-01338:2010","test_object_en":"Workplace environment − infrasonic noise","search_zh":"工作环境 － 次声噪声 PN-Z-01338:2010","test_object_zh":"工作环境 － 次声噪声"},{"_id":"6a83b7f4af14b9c0e7b210f7","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne,"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne,\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne,\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne,\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances,"},{"name":"respirable fraction"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction inorganic substances, respirable fraction PN-Z-04008-7:2002","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"substancje nieorganiczne,"},{"name":"呼吸性组分"}],"search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 呼吸性组分 PN-Z-04008-7:2002","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a83b7f4af14b9c0e7b210f8","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002","test_object_zh":"工作环境 − 空气"},{"_id":"6a83b7f4af14b9c0e7b210f9","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,007 – 0,5) mg/m³"},{"name":"Zakres","range":"(5 – 400) µg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,007 – 0,5) mg/m³\nZakres (5 – 400) µg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,007 – 0,5) mg/m³\nZakres (5 – 400) µg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130 Srodowisko pracy − powietrze Stezenie/zawartosc krystalicznej krzemionki (kwarc, krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,007 – 0,5) mg/m³\nZakres (5 – 400) µg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, Nr 4 (74), str. 117-130","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystalline silica (quartz, cristobalite) concentration/content","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,007 – 0,5) mg/m³"},{"name":"Range","range":"(5 – 400) µg w próbce"}],"search_en":"Workplace environment − air Crystalline silica (quartz, cristobalite) concentration/content Fourier transform infrared spectrometry (FT-IR) respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,007 – 0,5) mg/m³"},{"name":"范围","range":"(5 – 400) µg w próbce"}],"search_zh":"工作环境 − 空气 结晶二氧化硅（石英、方石英）的浓度/含量 傅里叶变换红外光谱法（FT-IR） 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130","test_object_zh":"工作环境 − 空气","methodology_zh":"结晶二氧化硅（石英、方石英）的浓度/含量","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a83b7f4af14b9c0e7b210fa","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,13– 20,8) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nZakres (0,13– 20,8) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nZakres (0,13– 20,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nWegiel (kamienny, brunatny)\nZakres (0,13– 20,8) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,13– 20,8) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents – inhalable fraction Gravimetric method Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Coal (hard, brown) Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,13– 20,8) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分 重量法 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 煤（烟煤、褐煤） 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a83b7f4af14b9c0e7b210fb","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,13 – 6,3) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,13 – 6,3) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,13 – 6,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,13 – 6,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,13 – 6,3) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents – respirable fraction Gravimetric method Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,13 – 6,3) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a83b7f4af14b9c0e7b210fc","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 − 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 − 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 − 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 − 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 − 5 000) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 − 5 000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a83b7f4af14b9c0e7b210fd","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a83b7f4af14b9c0e7b210fe","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(0 – 60) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 – 60) l/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (0 – 60) °C\nPrzepływ powietrza\nZakres (10 – 60) l/min\nMetoda pomiarowa bezpośrednia","reference":"PRB-001 wydanie 1 z dnia 27.02.2025 r.","norm_bases":["PRB-001 wydanie 1 z dnia 27.02.2025 r."],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 – 60) °C\nPrzepływ powietrza\nZakres (10 – 60) l/min\nMetoda pomiarowa bezpośrednia PRB-001 wydanie 1 z dnia 27.02.2025 r. Srodowisko pracy − wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 – 60) °C\nPrzeplyw powietrza\nZakres (10 – 60) l/min\nMetoda pomiarowa bezposrednia PRB-001 wydanie 1 z dnia 27.02.2025 r.","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(0 – 60) °C"},{"name":"Air flow"},{"name":"Range","range":"(10 – 60) l/min"}],"search_en":"Workplace environment − energy expenditure Air temperature Direct measurement method Range Air flow Range PRB-001 wydanie 1 z dnia 27.02.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(0 – 60) °C"},{"name":"空气流量"},{"name":"范围","range":"(10 – 60) l/min"}],"search_zh":"工作环境 － 能量代谢消耗 空气温度 直接测量法 范围 空气流量 范围 PRB-001 wydanie 1 z dnia 27.02.2025 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 能量代谢消耗"},{"_id":"6a83b7f4af14b9c0e7b210ff","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"PRB-001 wydanie 1 z dnia 27.02.2025 r.","norm_bases":["PRB-001 wydanie 1 z dnia 27.02.2025 r."],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − wydatek energetyczny Wydatek energetyczny (z obliczeń) PRB-001 wydanie 1 z dnia 27.02.2025 r. Srodowisko pracy − wydatek energetyczny Wydatek energetyczny (z obliczen) PRB-001 wydanie 1 z dnia 27.02.2025 r.","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment − energy expenditure Energy expenditure (calculated) PRB-001 wydanie 1 z dnia 27.02.2025 r.","test_object_en":"Workplace environment − energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"工作环境 － 能量代谢消耗 能量消耗（计算值） PRB-001 wydanie 1 z dnia 27.02.2025 r.","test_object_zh":"工作环境 － 能量代谢消耗"},{"_id":"6a83b7f4af14b9c0e7b21100","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyśpieszenie drgań","parameters":[{"name":"Zakres","range":"(0,02 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyśpieszenie drgań\nZakres (0,02 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyśpieszenie drgań\nZakres (0,02 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,02 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,02 – 100) m/s2"}],"search_en":"Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment − whole-body vibration","parameters_zh":[{"name":"范围","range":"(0,02 – 100) m/s2"}],"search_zh":"工作场所环境 − 全身振动 频率计权有效振动加速度 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 全身振动","methodology_zh":"频率计权有效振动加速度"},{"_id":"6a83b7f4af14b9c0e7b21101","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz)., Ekspozycja trwająca 30 min. i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz). (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz)., Ekspozycja trwająca 30 min. i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz). (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz)., Ekspozycja trwająca 30 min. i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz). (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz)., Ekspozycja trwajaca 30 min. i krocej wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz). (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz)., Exposure lasting 30 min. and less expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz). (calculated)","search_en":"Workplace environment − whole-body vibration Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz)., Exposure lasting 30 min. and less expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz). (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment − whole-body vibration","search_zh":"工作场所环境 − 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 − 全身振动"},{"_id":"6a83b7f4af14b9c0e7b21102","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyśpieszenie drgań","parameters":[{"name":"Zakres","range":"(0,2 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyśpieszenie drgań\nZakres (0,2 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyśpieszenie drgań\nZakres (0,2 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,2 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,2 – 100) m/s2"}],"search_en":"Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hand-arm vibration","parameters_zh":[{"name":"范围","range":"(0,2 – 100) m/s2"}],"search_zh":"工作场所环境 − 手传振动 频率计权有效振动加速度 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 手传振动","methodology_zh":"频率计权有效振动加速度"},{"_id":"6a83b7f4af14b9c0e7b21103","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 min. i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 min. i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 min. i krócej wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna wyrazona w postaci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwajaca 30 min. i krocej wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz)., Exposure lasting 30 min. and less expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment − hand-arm vibration Daily exposure expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz)., Exposure lasting 30 min. and less expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment − hand-arm vibration","search_zh":"工作场所环境 − 手传振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 − 手传振动"},{"_id":"6a83b7f4af14b9c0e7b21104","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30) – (+10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30) – (+10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 10,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30) – (+10) °C\nTemperatura poczernionej kuli\nZakres (-30) – (+10) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 10,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30) – (+10) °C\nTemperatura poczernionej kuli\nZakres (-30) – (+10) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 10,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30) – (+10) °C\nTemperatura poczernionej kuli\nZakres (-30) – (+10) °C\nWilgotnosc powietrza\nZakres (25 – 90) %\nPredkosc powietrza\nZakres (0,15 – 10,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30) – (+10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30) – (+10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 10,0) m/s"}],"search_en":"Workplace environment − cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30) – (+10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30) – (+10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 10,0) m/s"}],"search_zh":"工作场所环境 − 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a83b7f4af14b9c0e7b21105","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）","search_zh":"工作场所环境 − 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a83b7f4af14b9c0e7b21106","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(+10) – (+30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(+10) – (+40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (+10) – (+30) °C\nTemperatura poczernionej kuli\nZakres (+10) – (+40) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (+10) – (+30) °C\nTemperatura poczernionej kuli\nZakres (+10) – (+40) °C\nWilgotność powietrza\nZakres (25 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (+10) – (+30) °C\nTemperatura poczernionej kuli\nZakres (+10) – (+40) °C\nWilgotnosc powietrza\nZakres (25 – 90) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(+10) – (+30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(+10) – (+40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 1,0) m/s"}],"search_en":"Workplace environment − moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(+10) – (+30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(+10) – (+40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 − 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a83b7f4af14b9c0e7b21107","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment − moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 − 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a83b7f4af14b9c0e7b21108","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(20 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(20 – 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (20 – 50) °C\nTemperatura wilgotna naturalna\nZakres (15 – 50) °C\nTemperatura poczernionej kuli\nZakres (20 – 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (20 – 50) °C\nTemperatura wilgotna naturalna\nZakres (15 – 50) °C\nTemperatura poczernionej kuli\nZakres (20 – 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (20 – 50) °C\nTemperatura wilgotna naturalna\nZakres (15 – 50) °C\nTemperatura poczernionej kuli\nZakres (20 – 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(20 – 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15 – 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(20 – 60) °C"}],"search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(20 – 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(20 – 60) °C"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a83b7f4af14b9c0e7b21109","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a83b7f4af14b9c0e7b2110a","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca)","parameters":[{"name":"Zakres","range":"(2,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca)\nZakres (2,0 – 30,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A2","norm_bases":["PN-ISO 589:2006 Metoda A2"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoć przemijająca)\nZakres (2,0 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoc przemijajaca)\nZakres (2,0 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (transient moisture)","parameters_en":[{"name":"Range","range":"(2,0 – 30,0) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content (transient moisture) Gravimetric method Range PN-ISO 589:2006 Metoda A2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(2,0 – 30,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a83b7f4af14b9c0e7b2110b","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce)","parameters":[{"name":"Zakres","range":"(0,7 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce)\nZakres (0,7 – 15,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A2","norm_bases":["PN-ISO 589:2006 Metoda A2"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoć pozostała w próbce)\nZakres (0,7 – 15,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoc pozostala w probce)\nZakres (0,7 – 15,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (residual moisture in the sample)","parameters_en":[{"name":"Range","range":"(0,7 – 15,0) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (residual moisture in the sample) Gravimetric method Range PN-ISO 589:2006 Metoda A2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,7 – 15,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分（样品残余水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a83b7f4af14b9c0e7b2110c","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 Metoda A2","norm_bases":["PN-ISO 589:2006 Metoda A2"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 Metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 Metoda A2","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 Metoda A2","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 Metoda A2","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a83b7f4af14b9c0e7b2110d","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,50 – 15,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 15,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,50 – 15,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,50 – 15,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,50 – 15,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b2110e","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(5,00 – 50,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (5,00 – 50,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (5,00 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (5,00 – 50,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(5,00 – 50,00) %"}],"search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(5,00 – 50,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b2110f","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 15,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 15,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 15,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b21110","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(5,0 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (5,0 – 50,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (5,0 – 50,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (5,0 – 50,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(5,0 – 50,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(5,0 – 50,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b21111","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,20 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,20 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,20 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,20 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,20 – 2,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,20 – 2,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b21112","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(15000 – 35000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (15000 – 35000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (15000 – 35000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (15000 – 35000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(15000 – 35000) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(15000 – 35000) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b21113","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-ISO 1928:2020-05","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-ISO 1928:2020-05","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b21114","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(30,0 – 85,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (30,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (30,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (30,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(30,0 – 85,0) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(30,0 – 85,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b21115","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(2,50 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (2,50 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (2,50 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (2,50 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(2,50 – 6,00) %"}],"search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(2,50 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a83b7f4af14b9c0e7b21116","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość chloru całkowitego","parameters":[{"name":"Zakres","range":"(0,010 – 1,000) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość chloru całkowitego\nZakres (0,010 – 1,000) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 15408:2011","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość chloru całkowitego\nZakres (0,010 – 1,000) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012 Paliwa stale: wegiel kamienny Zawartosc chloru calkowitego\nZakres (0,010 – 1,000) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine content","parameters_en":[{"name":"Range","range":"(0,010 – 1,000) %"}],"search_en":"Solid fuels: hard coal Total chlorine content Ion chromatography with conductometric detection (IC-CD) Range PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,010 – 1,000) %"}],"search_zh":"固体燃料：烟煤 总氯含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN 15408:2011 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"固体燃料：烟煤","methodology_zh":"总氯含量"},{"_id":"6a83b7f4af14b9c0e7b21117","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,30 – 3,70) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,30 – 3,70) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,30 – 3,70) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,30 – 3,70) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998","categories":["petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,30 – 3,70) %"}],"search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,30 – 3,70) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a83b7f4af14b9c0e7b21118","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(3,0 – 65,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (3,0 – 65,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-2:2024-10"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci całkowitej\nZakres (3,0 – 65,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci calkowitej\nZakres (3,0 – 65,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(3,0 – 65,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Total moisture content Gravimetric method Range PN-EN ISO 18134-2:2024-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(3,0 – 65,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 全水分含量 重量法 范围 PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b21119","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(2,0 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (2,0 – 20,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (2,0 – 20,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (2,0 – 20,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(2,0 – 20,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 20,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b2111a","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(2,0 – 20,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (2,0 – 20,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wilgoci w próbce analitycznej\nZakres (2,0 – 20,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wilgoci w probce analitycznej\nZakres (2,0 – 20,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(2,0 – 20,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 18134-3:2023-12","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 20,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b2111b","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,3 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,3 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość popiołu\nZakres (0,3 – 40,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc popiolu\nZakres (0,3 – 40,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,3 – 40,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Ash content Gravimetric method Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,3 – 40,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 灰分含量 重量法 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b2111c","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,3 – 40,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,3 – 40,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość popiołu\nZakres (0,3 – 40,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc popiolu\nZakres (0,3 – 40,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,3 – 40,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Ash content Thermogravimetric method (TGA) Range PN-EN ISO 18122:2023-05","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,3 – 40,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 灰分含量 热重法（TGA） 范围 PN-EN ISO 18122:2023-05","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b2111d","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(10000 − 25000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (10000 − 25000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Ciepło spalania\nZakres (10000 − 25000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala - biopaliwo stale Cieplo spalania\nZakres (10000 − 25000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(10000 − 25000) kJ/kg"}],"search_en":"Solid fuels: solid biomass - solid biofuel Gross calorific value Calorimetric method Range PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10000 − 25000) kJ/kg"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 高位发热量 量热法 范围 PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b2111e","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Wartość opałowa (z obliczeń) PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala - biopaliwo stale Wartosc opalowa (z obliczen) PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: solid biomass - solid biofuel Net calorific value (calculated) PN-EN ISO 18125:2017-07","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：固体生物质 — 固体生物燃料 低位发热量（计算值） PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b2111f","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(22,0 – 55,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (22,0 – 55,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość węgla całkowitego\nZakres (22,0 – 55,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wegla calkowitego\nZakres (22,0 – 55,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(22,0 – 55,0) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(22,0 – 55,0) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b21120","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(4,00 – 8,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (4,00 – 8,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość wodoru\nZakres (4,00 – 8,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc wodoru\nZakres (4,00 – 8,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(4,00 – 8,00) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","parameters_zh":[{"name":"范围","range":"(4,00 – 8,00) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b21121","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc siarki calkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,02 – 1,00) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料"},{"_id":"6a83b7f4af14b9c0e7b21122","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość chloru całkowitego","parameters":[{"name":"Zakres","range":"(0,010 – 1,000) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość chloru całkowitego\nZakres (0,010 – 1,000) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 16994:2016-10 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 16994:2016-10","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość chloru całkowitego\nZakres (0,010 – 1,000) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 16994:2016-10 | PN-EN ISO 10304-1:2009+AC:2012 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc chloru calkowitego\nZakres (0,010 – 1,000) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 16994:2016-10 | PN-EN ISO 10304-1:2009+AC:2012","categories":["petro"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine content","parameters_en":[{"name":"Range","range":"(0,010 – 1,000) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Total chlorine content Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 16994:2016-10 | PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Solid fuels: solid biomass - solid biofuel","parameters_zh":[{"name":"范围","range":"(0,010 – 1,000) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 总氯含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 16994:2016-10 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料","methodology_zh":"总氯含量"},{"_id":"6a83b7f4af14b9c0e7b21123","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała - biopaliwo stałe","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,20 – 3,80) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,20 – 3,80) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biomasa stała - biopaliwo stałe Zawartość azotu\nZakres (0,20 – 3,80) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale: biomasa stala - biopaliwo stale Zawartosc azotu\nZakres (0,20 – 3,80) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,20 – 3,80) %"}],"search_en":"Solid fuels: solid biomass - solid biofuel Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels: solid biomass - solid biofuel","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,20 – 3,80) %"}],"search_zh":"固体燃料：固体生物质 — 固体生物燃料 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 16948:2015-07","test_object_zh":"固体燃料：固体生物质 — 固体生物燃料","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a83b7f4af14b9c0e7b21124","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,2 – 50,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,2 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość węgla całkowitego\nZakres (0,2 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materialy budowlane: popiol lotny; o) Kody badanych odpadow podane wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc wegla calkowitego\nZakres (0,2 – 50,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment","materials","construction"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,2 – 50,0) %"}],"search_en":"Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,2 – 50,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a83b7f4af14b9c0e7b21125","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Miałkość popiołu lotnego","parameters":[{"name":"Zakres","range":"(10,0 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Miałkość popiołu lotnego\nZakres (10,0 – 50,0) %\nMetoda wagowa","reference":"PN-EN 451-2:2017-06","norm_bases":["PN-EN 451-2:2017-06"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Miałkość popiołu lotnego\nZakres (10,0 – 50,0) %\nMetoda wagowa PN-EN 451-2:2017-06 Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materialy budowlane: popiol lotny; o) Kody badanych odpadow podane wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Mialkosc popiolu lotnego\nZakres (10,0 – 50,0) %\nMetoda wagowa PN-EN 451-2:2017-06","categories":["environment","materials","construction"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fineness of fly ash","parameters_en":[{"name":"Range","range":"(10,0 – 50,0) %"}],"search_en":"Fineness of fly ash Gravimetric method Range PN-EN 451-2:2017-06","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(10,0 – 50,0) %"}],"search_zh":"重量法 范围 PN-EN 451-2:2017-06","technique_zh":"重量法"},{"_id":"6a83b7f4af14b9c0e7b21126","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-ISO 11722:2009 Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materialy budowlane: popiol lotny; o) Kody badanych odpadow podane wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 10,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["environment","materials","construction"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,1 – 10,0) %"}],"search_en":"Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","technique_en":"Gravimetric method","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 10,0) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法"},{"_id":"6a83b7f4af14b9c0e7b21127","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,10 – 10,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materiały budowlane: popiół lotny; o) Kody badanych odpadów podane według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. Zawartość wilgoci w próbce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Odpady o) kod: 10 01 01, 10 01 02, 10 01 15, 10 01 17, Materialy budowlane: popiol lotny; o) Kody badanych odpadow podane wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow. Zawartosc wilgoci w probce analitycznej\nZakres (0,10 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["environment","materials","construction"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,10 – 10,00) %"}],"search_en":"Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,10 – 10,00) %"}],"search_zh":"分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）"},{"_id":"6a83b7f4af14b9c0e7b21128","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.2, p 5.3.6","norm_bases":["PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.2, p 5.3.6"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.2, p 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.2, p 5.3.6","categories":["petro"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.2, p 5.3.6","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.2, p 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83b7f4af14b9c0e7b21129","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Automatic method PN-ISO 5667-10:2021-11","technique_en":"Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"自动法"},{"_id":"6a83b7f4af14b9c0e7b2112a","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki ścieków\nZakres (0,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura pobranej próbki ścieków\nZakres (0,0 – 50,0) °C PN-77/C-04584 Scieki Temperatura pobranej probki sciekow\nZakres (0,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected wastewater sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Wastewater Temperature of the collected wastewater sample Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"污水 所采废水样品的温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"所采废水样品的温度"},{"_id":"6a83b7f4af14b9c0e7b2112b","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 Woda Pobieranie probek do badan chemicznych i fizycznych\nMetoda automatyczna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.5 i 7.6","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing Automatic method PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6","technique_en":"Automatic method","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 自动法 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6","test_object_zh":"水","technique_zh":"自动法"},{"_id":"6a83b7f4af14b9c0e7b2112c","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) °C PN-77/C-04584 Woda Temperatura pobranej probki wody\nZakres (0,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water Temperature of the collected water sample Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 所采水样的温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"所采水样的温度"},{"_id":"6a83b7f4af14b9c0e7b2112d","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"+ pH; + - badania wykonywanie w siedzibie i poza siedzibą Laboratorium","parameters":[{"name":"Zakres","range":"4,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"+ pH; + - badania wykonywanie w siedzibie i poza siedzibą Laboratorium\nZakres 4,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki + pH; + - badania wykonywanie w siedzibie i poza siedzibą Laboratorium\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki + pH; + - badania wykonywanie w siedzibie i poza siedziba Laboratorium\nZakres 4,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"4,0 − 10,0"}],"search_en":"Water, wastewater Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"4,0 − 10,0"}],"search_zh":"水、废水 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a83b7f4af14b9c0e7b2112e","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 200) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 200) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 200) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 200) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a83b7f4af14b9c0e7b2112f","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(10 – 40000) mg/l"},{"name":"fluorki","range":"(0,04 – 30) mg/l"},{"name":"siarczany","range":"(10 – 2500) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (10 – 40000) mg/l\nfluorki (0,04 – 30) mg/l\nsiarczany (10 – 2500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie anionów\nZakres:\nchlorki (10 – 40000) mg/l\nfluorki (0,04 – 30) mg/l\nsiarczany (10 – 2500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie anionow\nZakres:\nchlorki (10 – 40000) mg/l\nfluorki (0,04 – 30) mg/l\nsiarczany (10 – 2500) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(10 – 40000) mg/l"},{"name":"fluorides","range":"(0,04 – 30) mg/l"},{"name":"sulfates","range":"(10 – 2500) mg/l"}],"search_en":"Water, wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorides fluorides sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"阴离子浓度","search_zh":"水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水","parameters_zh":[{"name":"氯化物","range":"(10 – 40000) mg/l"},{"name":"氟化物","range":"(0,04 – 30) mg/l"},{"name":"硫酸盐","range":"(10 – 2500) mg/l"}]},{"_id":"6a83b7f4af14b9c0e7b21130","lab_id":"69ad52a3de79e566650fb4a6","country":"PL","accr_number":"AB 927","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków:","parameters":[{"name":"ołów","range":"(0,0050 – 5,0) mg/l"},{"name":"miedź","range":"(0,0050 – 5,0) mg/l"},{"name":"nikiel","range":"(0,0050 – 5,0) mg/l"},{"name":"chrom","range":"(0,0050 – 5,0) mg/l"},{"name":"kadm","range":"(0,00020 – 5,0) mg/l"},{"name":"cynk","range":"(0,0050 – 5,0) mg/l"},{"name":"arsen","range":"(0,0050 – 5,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków:\nZakres:\nołów (0,0050 – 5,0) mg/l\nmiedź (0,0050 – 5,0) mg/l\nnikiel (0,0050 – 5,0) mg/l\nchrom (0,0050 – 5,0) mg/l\nkadm (0,00020 – 5,0) mg/l\ncynk (0,0050 – 5,0) mg/l\narsen (0,0050 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków:\nZakres:\nołów (0,0050 – 5,0) mg/l\nmiedź (0,0050 – 5,0) mg/l\nnikiel (0,0050 – 5,0) mg/l\nchrom (0,0050 – 5,0) mg/l\nkadm (0,00020 – 5,0) mg/l\ncynk (0,0050 – 5,0) mg/l\narsen (0,0050 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow:\nZakres:\nolow (0,0050 – 5,0) mg/l\nmiedz (0,0050 – 5,0) mg/l\nnikiel (0,0050 – 5,0) mg/l\nchrom (0,0050 – 5,0) mg/l\nkadm (0,00020 – 5,0) mg/l\ncynk (0,0050 – 5,0) mg/l\narsen (0,0050 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentrations:","parameters_en":[{"name":"lead","range":"(0,0050 – 5,0) mg/l"},{"name":"copper","range":"(0,0050 – 5,0) mg/l"},{"name":"nickel","range":"(0,0050 – 5,0) mg/l"},{"name":"chromium","range":"(0,0050 – 5,0) mg/l"},{"name":"cadmium","range":"(0,00020 – 5,0) mg/l"},{"name":"zinc","range":"(0,0050 – 5,0) mg/l"},{"name":"arsenic","range":"(0,0050 – 5,0) mg/l"}],"search_en":"Water, wastewater Element concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) lead copper nickel chromium cadmium zinc arsenic PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"元素浓度：","parameters_zh":[{"name":"铅","range":"(0,0050 – 5,0) mg/l"},{"name":"铜","range":"(0,0050 – 5,0) mg/l"},{"name":"镍","range":"(0,0050 – 5,0) mg/l"},{"name":"铬","range":"(0,0050 – 5,0) mg/l"},{"name":"镉","range":"(0,00020 – 5,0) mg/l"},{"name":"锌","range":"(0,0050 – 5,0) mg/l"},{"name":"砷","range":"(0,0050 – 5,0) mg/l"}],"search_zh":"水、废水 元素浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 铅 铜 镍 铬 镉 锌 砷 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"}],"has_pdf":true}