{"lab":{"_id":"69ad52a3de79e566650fb498","accr_number":"AB 912","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Jana Długosza 40, 51-162 Wrocław","categories":["environment","materials"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":114,"name":"LEMITOR OCHRONA ŚRODOWISKA Sp. z o. o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_912.pdf"],"scope_summary":"","search_text":"lemitor ochrona środowiska sp. z o. o. laboratorium badawcze, ul. jana długosza 40, 51-162 wrocław other food environment materials automotive petro construction water metrology","status":"active","updated_at":"2026-03-08T14:51:48.527Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:29:25.710Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://www.lemitor.com.pl/kontakt/","fields_of_testing":[{"codes":"A/5; A/13; A/37","pl":"Badania akustyczne drgań – maszyny i urządzenia, obiekty budowlane, pomieszczenia, zakłady produkcyjne","en":"Acoustic and vibration tests – machinery and devices, building items, facilities production plants"},{"codes":"C/9/P; C/36/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek - powietrze, gazy odlotowe, gazy składowiskowe, ścieki","en":"Chemical tests and sampling - air, waste gases, landfill gases, sewage"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors - noise)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) - waste gases"},{"codes":"N/9/P; N/36/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek – powietrze, gazy odlotowe, ścieki","en":"Tests of physical properties and sampling – air, waste gases, sewage"},{"codes":"P/9; P/36","pl":"Pobieranie próbek powietrza, gazów odlotowych","en":"Sampling of air, waste gases"}],"issue":{"no":"22","date":"30.06.2026"},"parse_date":"2026-08-18T01:29:25.710Z","parse_source":"agent-claude-code","map_coord":[51.134045,17.063164],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"ul. Jana Długosza 40","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/f0eb3784e2f675f0730715d4c6238a29/AB%20912.pdf","has_en":true,"category_counts":{"environment":66,"other":38,"materials":11,"water":3,"construction":2,"petro":1},"category_scores":{"environment":36,"other":11.93,"materials":1,"water":0.07,"construction":0.03,"petro":0.01},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"ul. Jana Długosza 40","city":null,"postal":null}]},"methods":[{"_id":"6a83b575af14b9c0e7b20da4","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[{"name":"Prędkość"},{"name":"Zakres","range":"(1 – 20) m/s"}],"technique":"Metoda spiętrzenia; Metoda anemometryczna","techniques":["Metoda spiętrzenia","Metoda anemometryczna"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość\nZakres (1 – 20) m/s\nMetoda spiętrzenia; Metoda anemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość\nZakres (1 – 20) m/s\nMetoda spiętrzenia; Metoda anemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nZakres:\nPredkosc\nZakres (1 – 20) m/s\nMetoda spietrzenia; Metoda anemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters_en":[{"name":"Velocity"},{"name":"Range","range":"(1 – 20) m/s"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method; Anemometric method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Velocity Range PN-Z-04030-7:1994","technique_en":"Stagnation pressure method; Anemometric method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"速度"},{"name":"范围","range":"(1 – 20) m/s"}],"search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法；风速仪法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 速度 范围 PN-Z-04030-7:1994","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"皮托管法；风速仪法"},{"_id":"6a83b575af14b9c0e7b20da5","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust sampling for determination of dust concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 用于测定粉尘浓度的粉尘采样 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定粉尘浓度的粉尘采样"},{"_id":"6a83b575af14b9c0e7b20da6","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,0005 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,0005 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,0005 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,0005 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,0005 – 100) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0005 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20da7","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘排放量（计算值） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20da8","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki, tlenku węgla, dwutlenku węgla, tlenków azotu, tlenku azotu, tlenu","parameters":[{"name":"SO2","range":"(3 – 2900) mg/m3"},{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"CO2","range":"(0,1 − 20) %"},{"name":"NOX","range":"(2 – 4900) mg/m3"},{"name":"NO","range":"(2 – 3200) mg/m3"},{"name":"O2","range":"(0,4 – 21) %"},{"name":"O2","range":"(0,4 – 21) %"}],"technique":"Metoda NDIR; Metoda chemiluminescencyjna; Metoda elektrochemiczna; Metoda paramagnetyczna","techniques":["Metoda NDIR","Metoda chemiluminescencyjna","Metoda elektrochemiczna","Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie dwutlenku siarki, tlenku węgla, dwutlenku węgla, tlenków azotu, tlenku azotu, tlenu\nZakres:\nSO2 (3 – 2900) mg/m3\nCO (2,5 – 6250) mg/m3\nCO2 (0,1 − 20) %\nNOX (2 – 4900) mg/m3\nNO (2 – 3200) mg/m3\nO2 (0,4 – 21) %\nO2 (0,4 – 21) %\nMetoda NDIR; Metoda chemiluminescencyjna; Metoda elektrochemiczna; Metoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki, tlenku węgla, dwutlenku węgla, tlenków azotu, tlenku azotu, tlenu\nZakres:\nSO2 (3 – 2900) mg/m3\nCO (2,5 – 6250) mg/m3\nCO2 (0,1 − 20) %\nNOX (2 – 4900) mg/m3\nNO (2 – 3200) mg/m3\nO2 (0,4 – 21) %\nO2 (0,4 – 21) %\nMetoda NDIR; Metoda chemiluminescencyjna; Metoda elektrochemiczna; Metoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki, tlenku wegla, dwutlenku wegla, tlenkow azotu, tlenku azotu, tlenu\nZakres:\nSO2 (3 – 2900) mg/m3\nCO (2,5 – 6250) mg/m3\nCO2 (0,1 − 20) %\nNOX (2 – 4900) mg/m3\nNO (2 – 3200) mg/m3\nO2 (0,4 – 21) %\nO2 (0,4 – 21) %\nMetoda NDIR; Metoda chemiluminescencyjna; Metoda elektrochemiczna; Metoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of sulphur dioxide, carbon monoxide, carbon dioxide, nitrogen oxides, nitrogen monoxide, oxygen","parameters_en":[{"name":"SO2","range":"(3 – 2900) mg/m3"},{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"CO2","range":"(0,1 − 20) %"},{"name":"NOX","range":"(2 – 4900) mg/m3"},{"name":"NO","range":"(2 – 3200) mg/m3"},{"name":"O2","range":"(0,4 – 21) %"},{"name":"O2","range":"(0,4 – 21) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of sulphur dioxide, carbon monoxide, carbon dioxide, nitrogen oxides, nitrogen monoxide, oxygen NDIR method; Chemiluminescence method; Electrochemical method; Paramagnetic method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law SO2 CO CO2 NOX NO O2 O2 PN-ISO 10396:2001","technique_en":"NDIR method; Chemiluminescence method; Electrochemical method; Paramagnetic method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 SO2 CO CO2 NO O2 O2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"(3 – 2900) mg/m3"},{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"CO2","range":"(0,1 − 20) %"},{"name":"NOX","range":"(2 – 4900) mg/m3"},{"name":"NO","range":"(2 – 3200) mg/m3"},{"name":"O2","range":"(0,4 – 21) %"},{"name":"O2","range":"(0,4 – 21) %"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20da9","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2, CO, CO2, NO, NOx (NO i NO2 w przeliczeniu na NO2), O2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2, CO, CO2, NO, NOx (NO i NO2 w przeliczeniu na NO2), O2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2, CO, CO2, NO, NOx (NO i NO2 w przeliczeniu na NO2), O2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2, CO, CO2, NO, NOx (NO i NO2 w przeliczeniu na NO2), O2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of SO2, CO, CO2, NO, NOx (NO and NO2 calculated as NO2), O2 (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of SO2, CO, CO2, NO, NOx (NO and NO2 calculated as NO2), O2 (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-ISO 10396:2001","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-ISO 10396:2001","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20daa","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie masowe ogólnego gazowego węgla organicznego (TVOC)","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie masowe ogólnego gazowego węgla organicznego (TVOC)\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013","norm_bases":["PN-EN 12619:2013"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie masowe ogólnego gazowego węgla organicznego (TVOC)\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013 Gazy odlotowe Stezenie masowe ogolnego gazowego wegla organicznego (TVOC)\nZakres (2 – 1000) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Mass concentration of total gaseous organic carbon (TVOC)","parameters_en":[{"name":"Range","range":"(2 – 1000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Mass concentration of total gaseous organic carbon (TVOC) Continuous flame ionization detection method (FID) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 12619:2013","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/m3"}],"search_zh":"废气 连续火焰离子化检测法（FID） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 12619:2013","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a83b575af14b9c0e7b20dab","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja TVOC (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja TVOC (z obliczeń)","reference":"PN-EN 12619:2013","norm_bases":["PN-EN 12619:2013"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja TVOC (z obliczeń) PN-EN 12619:2013 Gazy odlotowe Emisja TVOC (z obliczen) PN-EN 12619:2013","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"TVOC emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases TVOC emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 12619:2013","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 总挥发性有机化合物（TVOC）排放（由计算得出） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 12619:2013","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总挥发性有机化合物（TVOC）排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20dac","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen chloride concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1911:2011","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氯化氢浓度测定采样 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1911:2011","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a83b575af14b9c0e7b20dad","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,20 − 200) mg/m3"},{"name":"Zakres","range":"(0,020 – 12,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,20 − 200) mg/m3\nZakres (0,020 – 12,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,20 − 200) mg/m3\nZakres (0,020 – 12,0) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,20 − 200) mg/m3\nZakres (0,020 – 12,0) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,20 − 200) mg/m3"},{"name":"Range","range":"(0,020 – 12,0) mg w próbce"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen chloride concentration/content Spectrophotometric method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,20 − 200) mg/m3"},{"name":"范围","range":"(0,020 – 12,0) mg w próbce"}],"search_zh":"废气 氯化氢的浓度/含量 分光光度法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20dae","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja chlorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja chlorowodoru (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja chlorowodoru (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen chloride emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen chloride emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1911:2011","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氯化氢排放量（计算值） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1911:2011","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a83b575af14b9c0e7b20daf","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenków azotu, tlenku azotu","parameters":[{"name":"NOX","range":"(2,1 – 4900) mg/m3"},{"name":"NO","range":"(1,4 – 3200) mg/m3"}],"technique":"Metoda chemiluminescencyjna CLA","techniques":["Metoda chemiluminescencyjna CLA"],"computed":[],"activity":"Stężenie tlenków azotu, tlenku azotu\nZakres:\nNOX (2,1 – 4900) mg/m3\nNO (1,4 – 3200) mg/m3\nMetoda chemiluminescencyjna CLA","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenków azotu, tlenku azotu\nZakres:\nNOX (2,1 – 4900) mg/m3\nNO (1,4 – 3200) mg/m3\nMetoda chemiluminescencyjna CLA PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenkow azotu, tlenku azotu\nZakres:\nNOX (2,1 – 4900) mg/m3\nNO (1,4 – 3200) mg/m3\nMetoda chemiluminescencyjna CLA PN-EN 14792:2017-04","categories":["other"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of nitrogen oxides, nitrogen monoxide","parameters_en":[{"name":"NOX","range":"(2,1 – 4900) mg/m3"},{"name":"NO","range":"(1,4 – 3200) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of nitrogen oxides, nitrogen monoxide Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law NOX NO PN-EN 14792:2017-04","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 NO PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NOX","range":"(2,1 – 4900) mg/m3"},{"name":"NO","range":"(1,4 – 3200) mg/m3"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20db0","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"NO, NOx emission (NO and NO2 calculated as NO2) (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14792:2017-04","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14792:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20db1","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,5 – 6250) mg/m3"}],"technique":"Metoda spektrometrii niedyspersyjnej w podczerwieni NDIR","techniques":["Metoda spektrometrii niedyspersyjnej w podczerwieni NDIR"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres (2,5 – 6250) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni NDIR","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres (2,5 – 6250) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni NDIR PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla\nZakres (2,5 – 6250) mg/m3\nMetoda spektrometrii niedyspersyjnej w podczerwieni NDIR PN-EN 15058:2017-04","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,5 – 6250) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Carbon monoxide concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 15058:2017-04","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(2,5 – 6250) mg/m3"}],"search_zh":"废气 一氧化碳浓度 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20db2","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN 15058:2017-04 Gazy odlotowe Emisja CO (z obliczen) PN-EN 15058:2017-04","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"CO emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases CO emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 15058:2017-04","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 CO 排放量（计算值） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 15058:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a83b575af14b9c0e7b20db3","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(0,4 - 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie tlenu\nZakres (0,4 - 21) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,4 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (0,4 - 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(0,4 - 21) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Oxygen concentration Paramagnetic method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14789:2017-04","technique_en":"Paramagnetic method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,4 - 21) %"}],"search_zh":"废气 氧浓度 顺磁法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"顺磁法"},{"_id":"6a83b575af14b9c0e7b20db4","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku węgla","parameters":[{"name":"Zakres","range":"(0,1 – 20) %"}],"technique":"Metoda spektrometrii niedyspersyjnej w podczerwieni NDIR","techniques":["Metoda spektrometrii niedyspersyjnej w podczerwieni NDIR"],"computed":[],"activity":"Stężenie dwutlenku węgla\nZakres (0,1 – 20) %\nMetoda spektrometrii niedyspersyjnej w podczerwieni NDIR","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla\nZakres (0,1 – 20) %\nMetoda spektrometrii niedyspersyjnej w podczerwieni NDIR ISO 12039:2019 Gazy odlotowe Stezenie dwutlenku wegla\nZakres (0,1 – 20) %\nMetoda spektrometrii niedyspersyjnej w podczerwieni NDIR ISO 12039:2019","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(0,1 – 20) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Carbon dioxide concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range ISO 12039:2019","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,1 – 20) %"}],"search_zh":"废气 二氧化碳浓度 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 ISO 12039:2019","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"二氧化碳浓度"},{"_id":"6a83b575af14b9c0e7b20db5","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO2 (z obliczeń)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO2 (z obliczeń) ISO 12039:2019 Gazy odlotowe Emisja CO2 (z obliczen) ISO 12039:2019","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"CO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases CO2 emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 12039:2019","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 CO2 排放（由计算得出） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 12039:2019","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO2 排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20db6","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of dust concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘浓度测定采样 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20db7","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,5 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,5 – 50) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20db8","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 粉尘排放量（计算值） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20db9","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(4 – 40) %"},{"name":"Zakres","range":"(29- 250) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (4 – 40) %\nZakres (29- 250) g/m3\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres:\nZakres (4 – 40) %\nZakres (29- 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres:\nZakres (4 – 40) %\nZakres (29- 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(4 – 40) %"},{"name":"Range","range":"(29- 250) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Range PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(4 – 40) %"},{"name":"范围","range":"(29- 250) g/m3"}],"search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 范围 PN-EN 14790:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a83b575af14b9c0e7b20dba","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia SO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-4","norm_bases":["PN-EN 14791:2017-4"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-4 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-4","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of SO2 concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of SO2 concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14791:2017-4","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 用于测定 SO2 浓度的采样 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14791:2017-4","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a83b575af14b9c0e7b20dbb","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki SO2","parameters":[{"name":"Zakres","range":"(0,83 – 1330) mg/m3"},{"name":"Zakres","range":"(0,1 – 40) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie dwutlenku siarki SO2\nZakres:\nZakres (0,83 – 1330) mg/m3\nZakres (0,1 – 40) mg w próbce\nMetoda toronowa","reference":"PN-EN 14791:2017-4","norm_bases":["PN-EN 14791:2017-4"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki SO2\nZakres:\nZakres (0,83 – 1330) mg/m3\nZakres (0,1 – 40) mg w próbce\nMetoda toronowa PN-EN 14791:2017-4 Gazy odlotowe Stezenie dwutlenku siarki SO2\nZakres:\nZakres (0,83 – 1330) mg/m3\nZakres (0,1 – 40) mg w probce\nMetoda toronowa PN-EN 14791:2017-4","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sulfur dioxide SO2 concentration","parameters_en":[{"name":"Range","range":"(0,83 – 1330) mg/m3"},{"name":"Range","range":"(0,1 – 40) mg w próbce"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sulfur dioxide SO2 concentration Thoron method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Range PN-EN 14791:2017-4","technique_en":"Thoron method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,83 – 1330) mg/m3"},{"name":"范围","range":"(0,1 – 40) mg w próbce"}],"search_zh":"废气 二氧化硫 SO2 浓度 钍射气法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 范围 PN-EN 14791:2017-4","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"钍射气法","methodology_zh":"二氧化硫 SO2 浓度"},{"_id":"6a83b575af14b9c0e7b20dbc","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-4","norm_bases":["PN-EN 14791:2017-4"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-4 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-4","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"SO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases SO2 emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14791:2017-4","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 SO2 排放量（计算值） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14791:2017-4","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a83b575af14b9c0e7b20dbd","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of hydrogen fluoride concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氟化氢浓度测定采样 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a83b575af14b9c0e7b20dbe","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość fluorowodoru","parameters":[{"name":"Zakres","range":"(0,1 – 200) mg/m3"},{"name":"Zakres","range":"(0,011 – 52,6) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,1 – 200) mg/m3\nZakres (0,011 – 52,6) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość fluorowodoru\nZakres:\nZakres (0,1 – 200) mg/m3\nZakres (0,011 – 52,6) mg w próbce\nMetoda potencjometryczna ISO 15713:2006 Gazy odlotowe Stezenie/zawartosc fluorowodoru\nZakres:\nZakres (0,1 – 200) mg/m3\nZakres (0,011 – 52,6) mg w probce\nMetoda potencjometryczna ISO 15713:2006","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen fluoride concentration/content","parameters_en":[{"name":"Range","range":"(0,1 – 200) mg/m3"},{"name":"Range","range":"(0,011 – 52,6) mg w próbce"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen fluoride concentration/content Potentiometric method Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,1 – 200) mg/m3"},{"name":"范围","range":"(0,011 – 52,6) mg w próbce"}],"search_zh":"废气 氟化氢的浓度/含量 电位法 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 范围 ISO 15713:2006","technique_zh":"电位法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氟化氢的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20dbf","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja fluorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluorowodoru (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja fluorowodoru (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja fluorowodoru (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen fluoride emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen fluoride emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 氟化氢排放（由计算得出） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氟化氢排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20dc0","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2005","categories":["materials"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2005","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2005","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20dc1","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość metali:","parameters":[{"name":"antymon","range":"(0,00030 – 20) mg/m3"},{"name":"Zakres","range":"(0,0030 – 2,0) mg w próbce"},{"name":"arsen","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce chrom","range":"(0,000030 – 1700) mg/m3"},{"name":"(0,0030 – 170) mg w próbce kadm","range":"(0,000015 – 10) mg/m3"},{"name":"(0,00015 – 1,0) mg w próbce kobalt","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce mangan","range":"(0,00030 – 20) mg/m3"},{"name":"(0,0030 – 2,0) mg w próbce miedź","range":"(0,00030 – 35) mg/m3"},{"name":"(0,0030 – 3,5) mg w próbce nikiel","range":"(0,00030 – 150) mg/m3"},{"name":"(0,0030 – 15) mg w próbce ołów","range":"(0,00030 – 500) mg/m3"},{"name":"(0,0030 – 50) mg w próbce wanad","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość metali:\nZakres:\nantymon (0,00030 – 20) mg/m3\nZakres (0,0030 – 2,0) mg w próbce\narsen (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w próbce chrom (0,000030 – 1700) mg/m3\n(0,0030 – 170) mg w próbce kadm (0,000015 – 10) mg/m3\n(0,00015 – 1,0) mg w próbce kobalt (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w próbce mangan (0,00030 – 20) mg/m3\n(0,0030 – 2,0) mg w próbce miedź (0,00030 – 35) mg/m3\n(0,0030 – 3,5) mg w próbce nikiel (0,00030 – 150) mg/m3\n(0,0030 – 15) mg w próbce ołów (0,00030 – 500) mg/m3\n(0,0030 – 50) mg w próbce wanad (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość metali:\nZakres:\nantymon (0,00030 – 20) mg/m3\nZakres (0,0030 – 2,0) mg w próbce\narsen (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w próbce chrom (0,000030 – 1700) mg/m3\n(0,0030 – 170) mg w próbce kadm (0,000015 – 10) mg/m3\n(0,00015 – 1,0) mg w próbce kobalt (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w próbce mangan (0,00030 – 20) mg/m3\n(0,0030 – 2,0) mg w próbce miedź (0,00030 – 35) mg/m3\n(0,0030 – 3,5) mg w próbce nikiel (0,00030 – 150) mg/m3\n(0,0030 – 15) mg w próbce ołów (0,00030 – 500) mg/m3\n(0,0030 – 50) mg w próbce wanad (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2005 Gazy odlotowe Stezenie/zawartosc metali:\nZakres:\nantymon (0,00030 – 20) mg/m3\nZakres (0,0030 – 2,0) mg w probce\narsen (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w probce chrom (0,000030 – 1700) mg/m3\n(0,0030 – 170) mg w probce kadm (0,000015 – 10) mg/m3\n(0,00015 – 1,0) mg w probce kobalt (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w probce mangan (0,00030 – 20) mg/m3\n(0,0030 – 2,0) mg w probce miedz (0,00030 – 35) mg/m3\n(0,0030 – 3,5) mg w probce nikiel (0,00030 – 150) mg/m3\n(0,0030 – 15) mg w probce olow (0,00030 – 500) mg/m3\n(0,0030 – 50) mg w probce wanad (0,000015 – 20) mg/m3\n(0,00015 – 2,0) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2005","categories":["materials"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Metal concentrations/contents:","parameters_en":[{"name":"antimony","range":"(0,00030 – 20) mg/m3"},{"name":"Range","range":"(0,0030 – 2,0) mg w próbce"},{"name":"arsenic","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg in the sample chromium","range":"(0,000030 – 1700) mg/m3"},{"name":"(0,0030 – 170) mg in the sample cadmium","range":"(0,000015 – 10) mg/m3"},{"name":"(0,00015 – 1,0) mg in sample cobalt","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg in sample manganese","range":"(0,00030 – 20) mg/m3"},{"name":"(0,0030 – 2,0) mg in sample copper","range":"(0,00030 – 35) mg/m3"},{"name":"(0,0030 – 3,5) mg in the sample nickel","range":"(0,00030 – 150) mg/m3"},{"name":"(0,0030 – 15) mg in the sample lead","range":"(0,00030 – 500) mg/m3"},{"name":"(0,0030 – 50) mg in the sample vanadium","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg in the sample"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Metal concentrations/contents: Inductively coupled plasma optical emission spectrometry (ICP-OES) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law antimony Range arsenic (0,00015 – 2,0) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in sample cobalt (0,00015 – 2,0) mg in sample manganese (0,0030 – 2,0) mg in sample copper (0,0030 – 3,5) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample vanadium (0,00015 – 2,0) mg in the sample PN-EN 14385:2005","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"锑","range":"(0,00030 – 20) mg/m3"},{"name":"范围","range":"(0,0030 – 2,0) mg w próbce"},{"name":"砷","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce chrom","range":"(0,000030 – 1700) mg/m3"},{"name":"(0,0030 – 170) mg w próbce kadm","range":"(0,000015 – 10) mg/m3"},{"name":"(0,00015 – 1,0) mg w próbce kobalt","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce mangan","range":"(0,00030 – 20) mg/m3"},{"name":"(0,0030 – 2,0) mg w próbce miedź","range":"(0,00030 – 35) mg/m3"},{"name":"(0,0030 – 3,5) mg w próbce nikiel","range":"(0,00030 – 150) mg/m3"},{"name":"(0,0030 – 15) mg w próbce ołów","range":"(0,00030 – 500) mg/m3"},{"name":"(0,0030 – 50) mg w próbce wanad","range":"(0,000015 – 20) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce"}],"search_zh":"废气 金属的浓度/含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 锑 范围 砷 PN-EN 14385:2005","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"金属的浓度/含量："},{"_id":"6a83b575af14b9c0e7b20dc2","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (z obliczeń)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (z obliczeń) PN-EN 14385:2005 Gazy odlotowe Emisja metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (z obliczen) PN-EN 14385:2005","categories":["materials","environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2005","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2005","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20dc3","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of total mercury concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of total mercury concentration Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 总汞浓度测定采样 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总汞浓度测定采样"},{"_id":"6a83b575af14b9c0e7b20dc4","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja Hg (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja Hg (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja Hg (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja Hg (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hg emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hg emission (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 Hg 排放（由计算得出） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"Hg 排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20dc5","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 单项气态有机化合物浓度测定采样 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a83b575af14b9c0e7b20dc6","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Zawartość metali:","parameters":[{"name":"antymon (0,0030 – 2,0) mg w próbce arsen (0,00030 – 2,0) mg w próbce chrom (0,0030 – 170) mg w próbce kadm (0,00015 – 1,0) mg w próbce kobalt (0,00015 – 2,0) mg w próbce mangan (0,0030 – 2,0) mg w próbce miedź (0,0030 – 3,5) mg w próbce nikiel (0,0030 – 15) mg w próbce ołów (0,0030 – 50) mg w próbce wanad (0,00015 – 2,0) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali:\nantymon (0,0030 – 2,0) mg w próbce arsen (0,00030 – 2,0) mg w próbce chrom (0,0030 – 170) mg w próbce kadm (0,00015 – 1,0) mg w próbce kobalt (0,00015 – 2,0) mg w próbce mangan (0,0030 – 2,0) mg w próbce miedź (0,0030 – 3,5) mg w próbce nikiel (0,0030 – 15) mg w próbce ołów (0,0030 – 50) mg w próbce wanad (0,00015 – 2,0) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Zawartość metali:\nantymon (0,0030 – 2,0) mg w próbce arsen (0,00030 – 2,0) mg w próbce chrom (0,0030 – 170) mg w próbce kadm (0,00015 – 1,0) mg w próbce kobalt (0,00015 – 2,0) mg w próbce mangan (0,0030 – 2,0) mg w próbce miedź (0,0030 – 3,5) mg w próbce nikiel (0,0030 – 15) mg w próbce ołów (0,0030 – 50) mg w próbce wanad (0,00015 – 2,0) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2005 Gazy odlotowe Zawartosc metali:\nantymon (0,0030 – 2,0) mg w probce arsen (0,00030 – 2,0) mg w probce chrom (0,0030 – 170) mg w probce kadm (0,00015 – 1,0) mg w probce kobalt (0,00015 – 2,0) mg w probce mangan (0,0030 – 2,0) mg w probce miedz (0,0030 – 3,5) mg w probce nikiel (0,0030 – 15) mg w probce olow (0,0030 – 50) mg w probce wanad (0,00015 – 2,0) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2005","categories":["materials"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Metal content:","parameters_en":[{"name":"antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample vanadium (0,00015 – 2,0) mg in the sample"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Metal content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample vanadium (0,00015 – 2,0) mg in the sample PN-EN 14385:2005","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 金属含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2005","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"金属含量："},{"_id":"6a83b575af14b9c0e7b20dc7","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość indywidualnych gazowych związków organicznych","parameters":[{"name":"Zakres","range":"1,2,4-trimetylobenzen"},{"name":"Zakres","range":"(0,25 – 2000) mg/m3"},{"name":"Zakres","range":"(0,0050 – 10) mg w próbce"},{"name":"aceton","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce akroleina","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce alkohol diacetonowy","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce benzen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butyloglikol","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 20) mg w próbce chlorek metylenu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksan","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksanon","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce epichlorohydryna","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etylobenzen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce fenol","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan butylobenzylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan dietylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dibutylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dimetylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dioktylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce heksan","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izobutanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izopropanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce ksylen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie/zawartość indywidualnych gazowych związków organicznych\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,25 – 2000) mg/m3\nZakres (0,0050 – 10) mg w próbce\naceton (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce akroleina (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce alkohol diacetonowy (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce benzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce butanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce butyloglikol (0,25 – 400) mg/m3\n(0,0050 – 20) mg w próbce chlorek metylenu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce cykloheksan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce cykloheksanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce cykloheksanon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce epichlorohydryna (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce etanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce etylobenzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce fenol (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan butylobenzylu (0,25 – 400) mg/m3\n(0,0050-2) mg w próbce ftalan dietylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan dibutylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan dimetylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan dioktylu (0,25 – 400) mg/m3\n(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce heksan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce izobutanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce izopropanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce ksylen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość indywidualnych gazowych związków organicznych\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,25 – 2000) mg/m3\nZakres (0,0050 – 10) mg w próbce\naceton (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce akroleina (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce alkohol diacetonowy (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce benzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce butanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce butyloglikol (0,25 – 400) mg/m3\n(0,0050 – 20) mg w próbce chlorek metylenu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce cykloheksan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce cykloheksanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce cykloheksanon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce epichlorohydryna (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce etanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce etylobenzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce fenol (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan butylobenzylu (0,25 – 400) mg/m3\n(0,0050-2) mg w próbce ftalan dietylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan dibutylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan dimetylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce ftalan dioktylu (0,25 – 400) mg/m3\n(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w próbce heksan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce izobutanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce izopropanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce ksylen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc indywidualnych gazowych zwiazkow organicznych\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,25 – 2000) mg/m3\nZakres (0,0050 – 10) mg w probce\naceton (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce akroleina (0,25 – 400) mg/m3\n(0,0050 – 2) mg w probce alkohol diacetonowy (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce benzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce butanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce butyloglikol (0,25 – 400) mg/m3\n(0,0050 – 20) mg w probce chlorek metylenu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce cykloheksan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce cykloheksanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce cykloheksanon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce epichlorohydryna (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce etanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce etylobenzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce fenol (0,25 – 400) mg/m3\n(0,0050 – 2) mg w probce ftalan butylobenzylu (0,25 – 400) mg/m3\n(0,0050-2) mg w probce ftalan dietylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w probce ftalan dibutylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w probce ftalan dimetylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w probce ftalan dioktylu (0,25 – 400) mg/m3\n(0,0050-2) mg w probce ftalan bis-2-etyloheksylu (0,25 – 400) mg/m3\n(0,0050 – 2) mg w probce heksan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce izobutanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce izopropanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce ksylen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce PN-EN 13649:2005","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of individual gaseous organic compounds","parameters_en":[{"name":"Range","range":"1,2,4-trimetylobenzen"},{"name":"Range","range":"(0,25 – 2000) mg/m3"},{"name":"Range","range":"(0,0050 – 10) mg w próbce"},{"name":"acetone","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample acrolein","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg in sample diacetone alcohol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample benzene","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample butanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample butyl glycol","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 20) mg in sample methylene chloride","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample cyclohexane","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample cyclohexanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in the sample cyclohexanone","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample epichlorohydrin","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample ethanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample ethylbenzene","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample phenol","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg in sample benzyl butyl phthalate","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050-2) mg in sample diethyl phthalate","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg in sample dibutyl phthalate","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg in sample dimethyl phthalate","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg in sample dioctyl phthalate","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050-2) mg in sample bis(2-ethylhexyl) phthalate","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg in sample hexane","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample isobutanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample isopropanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in the sample xylene","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in the sample"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration/content of individual gaseous organic compounds Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Range Range acetone (0,0050 – 10) mg in sample acrolein (0,0050 – 2) mg in sample diacetone alcohol (0,0050 – 10) mg in sample benzene (0,0050 – 10) mg in sample butanol (0,0050 – 10) mg in sample butyl glycol (0,0050 – 20) mg in sample methylene chloride (0,0050 – 10) mg in sample cyclohexane (0,0050 – 10) mg in sample cyclohexanol (0,0050 – 10) mg in the sample cyclohexanone (0,0050 – 10) mg in sample epichlorohydrin (0,0050 – 10) mg in sample ethanol (0,0050 – 10) mg in sample ethylbenzene (0,0050 – 10) mg in sample phenol (0,0050 – 2) mg in sample benzyl butyl phthalate (0,0050-2) mg in sample diethyl phthalate (0,0050 – 2) mg in sample dibutyl phthalate (0,0050 – 2) mg in sample dimethyl phthalate (0,0050 – 2) mg in sample dioctyl phthalate (0,0050-2) mg in sample bis(2-ethylhexyl) phthalate (0,0050 – 2) mg in sample hexane (0,0050 – 10) mg in sample isobutanol (0,0050 – 10) mg in sample isopropanol (0,0050 – 10) mg in the sample xylene (0,0050 – 10) mg in the sample PN-EN 13649:2005","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"1,2,4-trimetylobenzen"},{"name":"范围","range":"(0,25 – 2000) mg/m3"},{"name":"范围","range":"(0,0050 – 10) mg w próbce"},{"name":"丙酮","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce akroleina","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce alkohol diacetonowy","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce benzen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butyloglikol","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 20) mg w próbce chlorek metylenu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksan","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksanon","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce epichlorohydryna","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etylobenzen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce fenol","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan butylobenzylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan dietylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dibutylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dimetylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dioktylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 2) mg w próbce heksan","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izobutanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izopropanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce ksylen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg/样品"}],"search_zh":"废气 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 范围 范围 丙酮 (0,0050 – 10) mg/样品 PN-EN 13649:2005","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20dc8","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie/zawartość indywidualnych gazowych związków organicznych","parameters":[{"name":"kumen","range":"(0,25 – 2000) mg/m3"},{"name":"Zakres","range":"(0,0050 – 10) mg w próbce"},{"name":"kwas octowy","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metakrylan metylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloetyloketon","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloizobutyloketon","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce mezytylen","range":"(1,3,5-trimetylobenzen)"},{"name":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan butylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan etylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan metylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan winylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce pentan","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce propylobenzen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce styren","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce toluen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory alifatyczne","range":"(suma C5 - C12)"},{"name":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma)","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość indywidualnych gazowych związków organicznych\nZakres:\nkumen (0,25 – 2000) mg/m3\nZakres (0,0050 – 10) mg w próbce\nkwas octowy (0,25 – 400) mg/m3\n(0,0050 – 10) mg w próbce metakrylan metylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce metanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce metyloetyloketon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce metyloizobutyloketon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce mezytylen (1,3,5-trimetylobenzen)\n(0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan butylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan etylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan metylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan winylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce pentan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce propylobenzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce styren (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce toluen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce węglowodory alifatyczne (suma C5 - C12)\n(0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma) (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie/zawartość indywidualnych gazowych związków organicznych\nZakres:\nkumen (0,25 – 2000) mg/m3\nZakres (0,0050 – 10) mg w próbce\nkwas octowy (0,25 – 400) mg/m3\n(0,0050 – 10) mg w próbce metakrylan metylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce metanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce metyloetyloketon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce metyloizobutyloketon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce mezytylen (1,3,5-trimetylobenzen)\n(0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan butylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan etylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan metylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce octan winylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce pentan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce propylobenzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce styren (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce toluen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce węglowodory alifatyczne (suma C5 - C12)\n(0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma) (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe Stezenie/zawartosc indywidualnych gazowych zwiazkow organicznych\nZakres:\nkumen (0,25 – 2000) mg/m3\nZakres (0,0050 – 10) mg w probce\nkwas octowy (0,25 – 400) mg/m3\n(0,0050 – 10) mg w probce metakrylan metylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce metanol (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce metyloetyloketon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce metyloizobutyloketon (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce mezytylen (1,3,5-trimetylobenzen)\n(0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce octan butylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce octan etylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce octan metylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce octan winylu (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce pentan (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce propylobenzen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce styren (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce toluen (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce weglowodory alifatyczne (suma C5 - C12)\n(0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce weglowodory aromatyczne (suma) (0,25 – 2000) mg/m3\n(0,0050 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of individual gaseous organic compounds","parameters_en":[{"name":"cumene","range":"(0,25 – 2000) mg/m3"},{"name":"Range","range":"(0,0050 – 10) mg w próbce"},{"name":"acetic acid","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl methacrylate","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample methanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl ethyl ketone","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl isobutyl ketone","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample mesitylene","range":"(1,3,5-trimetylobenzen)"},{"name":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample butyl acetate","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample ethyl acetate","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl acetate","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample vinyl acetate","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample pentane","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample propylbenzene","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample styrene","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample toluene","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample aliphatic hydrocarbons","range":"(suma C5 - C12)"},{"name":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in sample aromatic hydrocarbons (sum)","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg in the sample"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration/content of individual gaseous organic compounds Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law cumene Range acetic acid (0,0050 – 10) mg in sample methyl methacrylate (0,0050 – 10) mg in sample methanol (0,0050 – 10) mg in sample methyl ethyl ketone (0,0050 – 10) mg in sample methyl isobutyl ketone (0,0050 – 10) mg in sample mesitylene (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample butyl acetate (0,0050 – 10) mg in sample ethyl acetate (0,0050 – 10) mg in sample methyl acetate (0,0050 – 10) mg in sample vinyl acetate (0,0050 – 10) mg in sample pentane (0,0050 – 10) mg in sample propylbenzene (0,0050 – 10) mg in sample styrene (0,0050 – 10) mg in sample toluene (0,0050 – 10) mg in sample aliphatic hydrocarbons (0,25 – 2000) mg/m3 (0,0050 – 10) mg in sample aromatic hydrocarbons (sum) (0,0050 – 10) mg in the sample PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"异丙苯","range":"(0,25 – 2000) mg/m3"},{"name":"范围","range":"(0,0050 – 10) mg w próbce"},{"name":"乙酸","range":"(0,25 – 400) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metakrylan metylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metanol","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloetyloketon","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloizobutyloketon","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce mezytylen","range":"(1,3,5-trimetylobenzen)"},{"name":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan butylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan etylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan metylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan winylu","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce pentan","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce propylobenzen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce styren","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce toluen","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory alifatyczne","range":"(suma C5 - C12)"},{"name":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma)","range":"(0,25 – 2000) mg/m3"},{"name":"(0,0050 – 10) mg/样品"}],"search_zh":"废气 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 异丙苯 范围 乙酸 (0,0050 – 10) mg/样品 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20dc9","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of individual gaseous organic compounds (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) Testing Laboratory Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13649:2005","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 单项气态有机化合物排放量（计算值） 检测实验室 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83b575af14b9c0e7b20dca","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki, tlenku węgla, tlenku azotu, dwutlenku azotu, tlenu","parameters":[{"name":"SO2","range":"(3 – 2900) mg/m3"},{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"NO","range":"(1,4 – 4020) mg/m3"},{"name":"NO2","range":"(4 – 990) mg/m3"},{"name":"O2","range":"(2 – 21) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie dwutlenku siarki, tlenku węgla, tlenku azotu, dwutlenku azotu, tlenu\nZakres:\nSO2 (3 – 2900) mg/m3\nCO (2,5 – 6250) mg/m3\nNO (1,4 – 4020) mg/m3\nNO2 (4 – 990) mg/m3\nO2 (2 – 21) %\nMetoda elektrochemiczna","reference":"PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PN-ISO 10396:2001","PB-03 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki, tlenku węgla, tlenku azotu, dwutlenku azotu, tlenu\nZakres:\nSO2 (3 – 2900) mg/m3\nCO (2,5 – 6250) mg/m3\nNO (1,4 – 4020) mg/m3\nNO2 (4 – 990) mg/m3\nO2 (2 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r. Gazy odlotowe Stezenie dwutlenku siarki, tlenku wegla, tlenku azotu, dwutlenku azotu, tlenu\nZakres:\nSO2 (3 – 2900) mg/m3\nCO (2,5 – 6250) mg/m3\nNO (1,4 – 4020) mg/m3\nNO2 (4 – 990) mg/m3\nO2 (2 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of sulphur dioxide, carbon monoxide, nitrogen monoxide, nitrogen dioxide, oxygen","parameters_en":[{"name":"SO2","range":"(3 – 2900) mg/m3"},{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"NO","range":"(1,4 – 4020) mg/m3"},{"name":"NO2","range":"(4 – 990) mg/m3"},{"name":"O2","range":"(2 – 21) %"}],"search_en":"Waste gases Concentration of sulphur dioxide, carbon monoxide, nitrogen monoxide, nitrogen dioxide, oxygen Electrochemical method Testing Laboratory SO2 CO NO NO2 O2 PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","technique_en":"Electrochemical method","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 电化学法 检测实验室 SO2 CO NO NO2 O2 PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","technique_zh":"电化学法","test_object_zh":"废气","parameters_zh":[{"name":"SO2","range":"(3 – 2900) mg/m3"},{"name":"CO","range":"(2,5 – 6250) mg/m3"},{"name":"NO","range":"(1,4 – 4020) mg/m3"},{"name":"NO2","range":"(4 – 990) mg/m3"},{"name":"O2","range":"(2 – 21) %"}]},{"_id":"6a83b575af14b9c0e7b20dcb","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2, CO, NO i NOx (w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2, CO, NO i NOx (w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PN-ISO 10396:2001","PB-03 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja SO2, CO, NO i NOx (w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r. Gazy odlotowe Emisja SO2, CO, NO i NOx (w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of SO2, CO, NO and NOx (calculated as NO2) (calculated)","search_en":"Waste gases Emission of SO2, CO, NO and NOx (calculated as NO2) (calculated) Testing Laboratory PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PN-ISO 10396:2001 | PB-03 edycja 4 z dnia 01.02.2023 r.","test_object_zh":"废气"},{"_id":"6a83b575af14b9c0e7b20dcc","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia: amoniaku chloru, fluoru i fluorków, formaldehydu, izocyjanianów – MDI, TDI, kwasu siarkowego, siarkowodoru, cyjanowodoru","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia: amoniaku chloru, fluoru i fluorków, formaldehydu, izocyjanianów – MDI, TDI, kwasu siarkowego, siarkowodoru, cyjanowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"PB-16B edycja 2 z dnia 01.02.2023 r.","norm_bases":["PB-16B edycja 2 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia: amoniaku chloru, fluoru i fluorków, formaldehydu, izocyjanianów – MDI, TDI, kwasu siarkowego, siarkowodoru, cyjanowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających PB-16B edycja 2 z dnia 01.02.2023 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia: amoniaku chloru, fluoru i fluorkow, formaldehydu, izocyjanianow – MDI, TDI, kwasu siarkowego, siarkowodoru, cyjanowodoru\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych PB-16B edycja 2 z dnia 01.02.2023 r.","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the concentration of: ammonia chlorine, fluorine and fluorides, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide, hydrogen cyanide","search_en":"Waste gases Sampling for determination of the concentration of: ammonia chlorine, fluorine and fluorides, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide, hydrogen cyanide Aspiration method using absorbing solutions Testing Laboratory PB-16B edycja 2 z dnia 01.02.2023 r.","technique_en":"Aspiration method using absorbing solutions","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 采用吸收液的抽气法 检测实验室 PB-16B edycja 2 z dnia 01.02.2023 r.","test_object_zh":"废气","technique_zh":"采用吸收液的抽气法"},{"_id":"6a83b575af14b9c0e7b20dcd","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia związków siarkoorganicznych i metanu","parameters":[],"technique":"Metoda izolacyjna z zastosowaniem worków tedlarowych","techniques":["Metoda izolacyjna z zastosowaniem worków tedlarowych"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia związków siarkoorganicznych i metanu\nMetoda izolacyjna z zastosowaniem worków tedlarowych","reference":"PB-61 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PB-61 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia związków siarkoorganicznych i metanu\nMetoda izolacyjna z zastosowaniem worków tedlarowych PB-61 edycja 4 z dnia 01.02.2023 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia zwiazkow siarkoorganicznych i metanu\nMetoda izolacyjna z zastosowaniem workow tedlarowych PB-61 edycja 4 z dnia 01.02.2023 r.","categories":["construction"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the concentration of organosulfur compounds and methane","search_en":"Waste gases Sampling for determination of the concentration of organosulfur compounds and methane Isolation method using Tedlar bags Testing Laboratory PB-61 edycja 4 z dnia 01.02.2023 r.","technique_en":"Isolation method using Tedlar bags","test_object_en":"Waste gases","lab_section_zh":"检测实验室","search_zh":"废气 检测实验室 PB-61 edycja 4 z dnia 01.02.2023 r.","test_object_zh":"废气"},{"_id":"6a83b575af14b9c0e7b20dce","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,5 – 800) mg/m3"},{"name":"(0,020 − 8) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (0,5 – 800) mg/m3\n(0,020 − 8) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-11 edycja 9 z dnia 01.02.2023 r.","norm_bases":["PB-11 edycja 9 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość amoniaku\nZakres:\nZakres (0,5 – 800) mg/m3\n(0,020 − 8) mg w próbce\nMetoda spektrofotometryczna PB-11 edycja 9 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc amoniaku\nZakres:\nZakres (0,5 – 800) mg/m3\n(0,020 − 8) mg w probce\nMetoda spektrofotometryczna PB-11 edycja 9 z dnia 01.02.2023 r.","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(0,5 – 800) mg/m3"},{"name":"(0,020 − 8) mg in the sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Ammonia concentration/content Spectrophotometric method Testing Laboratory Range (0,020 − 8) mg in the sample PB-11 edycja 9 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 800) mg/m3"},{"name":"(0,020 − 8) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 氨浓度/含量 分光光度法 检测实验室 范围 PB-11 edycja 9 z dnia 01.02.2023 r.","technique_zh":"分光光度法","methodology_zh":"氨浓度/含量","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dcf","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PB-11 edycja 9 z dnia 01.02.2023 r.","norm_bases":["PB-11 edycja 9 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja amoniaku (z obliczeń) PB-11 edycja 9 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja amoniaku (z obliczen) PB-11 edycja 9 z dnia 01.02.2023 r.","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia emission (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Ammonia emission (calculated) Testing Laboratory PB-11 edycja 9 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 氨排放量（计算值） 检测实验室 PB-11 edycja 9 z dnia 01.02.2023 r.","methodology_zh":"氨排放量（计算值）","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd0","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of ammonia concentration","search_en":"Waste gases, Waste gas samples collected into absorbing solution Sampling for determination of ammonia concentration Testing Laboratory PN-EN ISO 21877:2020-03","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 氨浓度测定采样 检测实验室 PN-EN ISO 21877:2020-03","methodology_zh":"氨浓度测定采样","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd1","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,09 − 190) mg/m3"},{"name":"Zakres","range":"(0,01 – 11,25) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (0,09 − 190) mg/m3\nZakres (0,01 – 11,25) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość amoniaku\nZakres:\nZakres (0,09 − 190) mg/m3\nZakres (0,01 – 11,25) mg w próbce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc amoniaku\nZakres:\nZakres (0,09 − 190) mg/m3\nZakres (0,01 – 11,25) mg w probce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(0,09 − 190) mg/m3"},{"name":"Range","range":"(0,01 – 11,25) mg w próbce"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Ammonia concentration/content Spectrophotometric method Testing Laboratory Range Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,09 − 190) mg/m3"},{"name":"范围","range":"(0,01 – 11,25) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 氨浓度/含量 分光光度法 检测实验室 范围 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","methodology_zh":"氨浓度/含量","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd2","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia emission (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Ammonia emission (calculated) Testing Laboratory PN-EN ISO 21877:2020-03","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 氨排放量（计算值） 检测实验室 PN-EN ISO 21877:2020-03","methodology_zh":"氨排放量（计算值）","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd3","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość chloru","parameters":[{"name":"Zakres","range":"(0,05 − 1) mg/m3"},{"name":"(0,002 − 0,014) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,05 − 1) mg/m3\n(0,002 − 0,014) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-13 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-13 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość chloru\nZakres:\nZakres (0,05 − 1) mg/m3\n(0,002 − 0,014) mg w próbce\nMetoda spektrofotometryczna PB-13 edycja 7 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc chloru\nZakres:\nZakres (0,05 − 1) mg/m3\n(0,002 − 0,014) mg w probce\nMetoda spektrofotometryczna PB-13 edycja 7 z dnia 01.02.2023 r.","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Chlorine concentration/content","parameters_en":[{"name":"Range","range":"(0,05 − 1) mg/m3"},{"name":"(0,002 − 0,014) mg in sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Chlorine concentration/content Spectrophotometric method Testing Laboratory Range (0,002 − 0,014) mg in sample PB-13 edycja 7 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,05 − 1) mg/m3"},{"name":"(0,002 − 0,014) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 氯的浓度/含量 分光光度法 检测实验室 范围 PB-13 edycja 7 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"氯的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20dd4","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja chloru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chloru (z obliczeń)","reference":"PB-13 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-13 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja chloru (z obliczeń) PB-13 edycja 7 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja chloru (z obliczen) PB-13 edycja 7 z dnia 01.02.2023 r.","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Chlorine emission (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Chlorine emission (calculated) Testing Laboratory PB-13 edycja 7 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 氯排放（由计算得出） 检测实验室 PB-13 edycja 7 z dnia 01.02.2023 r.","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"氯排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20dd5","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia fluoru i jego związków","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluoru i jego związków","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia fluoru i jego związków ISO 15713:2006 Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia fluoru i jego zwiazkow ISO 15713:2006","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the concentration of fluorine and its compounds","search_en":"Waste gases, Waste gas samples collected into absorbing solution Sampling for determination of the concentration of fluorine and its compounds Testing Laboratory ISO 15713:2006","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 检测实验室 ISO 15713:2006","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd6","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość fluoru i jego związków","parameters":[{"name":"Zakres","range":"(0,1 – 200) mg/m3"},{"name":"Zakres","range":"(0,010 – 50) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość fluoru i jego związków\nZakres:\nZakres (0,1 – 200) mg/m3\nZakres (0,010 – 50) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość fluoru i jego związków\nZakres:\nZakres (0,1 – 200) mg/m3\nZakres (0,010 – 50) mg w próbce\nMetoda potencjometryczna ISO 15713:2006 Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc fluoru i jego zwiazkow\nZakres:\nZakres (0,1 – 200) mg/m3\nZakres (0,010 – 50) mg w probce\nMetoda potencjometryczna ISO 15713:2006","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of fluorine and its compounds","parameters_en":[{"name":"Range","range":"(0,1 – 200) mg/m3"},{"name":"Range","range":"(0,010 – 50) mg w próbce"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Concentration/content of fluorine and its compounds Potentiometric method Testing Laboratory Range Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,1 – 200) mg/m3"},{"name":"范围","range":"(0,010 – 50) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 电位法 检测实验室 范围 范围 ISO 15713:2006","technique_zh":"电位法","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd7","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja fluoru i jego związków (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluoru i jego związków (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja fluoru i jego związków (z obliczeń) ISO 15713:2006 Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja fluoru i jego zwiazkow (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of fluorine and its compounds (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Emission of fluorine and its compounds (calculated) Testing Laboratory ISO 15713:2006","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 检测实验室 ISO 15713:2006","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd8","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość fluoru i fluorków","parameters":[{"name":"Zakres","range":"(0,1 − 8000) mg/m3"},{"name":"(0,0040 − 20) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość fluoru i fluorków\nZakres:\nZakres (0,1 − 8000) mg/m3\n(0,0040 − 20) mg w próbce\nMetoda potencjometryczna","reference":"PB-15 edycja 6 z dnia 01.02.2023 r.","norm_bases":["PB-15 edycja 6 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość fluoru i fluorków\nZakres:\nZakres (0,1 − 8000) mg/m3\n(0,0040 − 20) mg w próbce\nMetoda potencjometryczna PB-15 edycja 6 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc fluoru i fluorkow\nZakres:\nZakres (0,1 − 8000) mg/m3\n(0,0040 − 20) mg w probce\nMetoda potencjometryczna PB-15 edycja 6 z dnia 01.02.2023 r.","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of fluorine and fluorides","parameters_en":[{"name":"Range","range":"(0,1 − 8000) mg/m3"},{"name":"(0,0040 − 20) mg in sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Concentration/content of fluorine and fluorides Potentiometric method Testing Laboratory Range (0,0040 − 20) mg in sample PB-15 edycja 6 z dnia 01.02.2023 r.","technique_en":"Potentiometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,1 − 8000) mg/m3"},{"name":"(0,0040 − 20) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 电位法 检测实验室 范围 PB-15 edycja 6 z dnia 01.02.2023 r.","technique_zh":"电位法","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dd9","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja fluoru i fluorków (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluoru i fluorków (z obliczeń)","reference":"PB-15 edycja 6 z dnia 01.02.2023 r.","norm_bases":["PB-15 edycja 6 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja fluoru i fluorków (z obliczeń) PB-15 edycja 6 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja fluoru i fluorkow (z obliczen) PB-15 edycja 6 z dnia 01.02.2023 r.","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of fluorine and fluorides (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Emission of fluorine and fluorides (calculated) Testing Laboratory PB-15 edycja 6 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 检测实验室 PB-15 edycja 6 z dnia 01.02.2023 r.","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dda","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,050 − 160) mg/m3"},{"name":"(0,0020 − 1,6) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,050 − 160) mg/m3\n(0,0020 − 1,6) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-06 edycja 9 z dnia 01.02.2023 r.","norm_bases":["PB-06 edycja 9 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,050 − 160) mg/m3\n(0,0020 − 1,6) mg w próbce\nMetoda spektrofotometryczna PB-06 edycja 9 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,050 − 160) mg/m3\n(0,0020 − 1,6) mg w probce\nMetoda spektrofotometryczna PB-06 edycja 9 z dnia 01.02.2023 r.","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,050 − 160) mg/m3"},{"name":"(0,0020 − 1,6) mg in the sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Formaldehyde concentration/content Spectrophotometric method Testing Laboratory Range (0,0020 − 1,6) mg in the sample PB-06 edycja 9 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,050 − 160) mg/m3"},{"name":"(0,0020 − 1,6) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 甲醛浓度/含量 分光光度法 检测实验室 范围 PB-06 edycja 9 z dnia 01.02.2023 r.","technique_zh":"分光光度法","methodology_zh":"甲醛浓度/含量","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20ddb","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja formaldehydu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja formaldehydu (z obliczeń)","reference":"PB-06 edycja 9 z dnia 01.02.2023 r.","norm_bases":["PB-06 edycja 9 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja formaldehydu (z obliczeń) PB-06 edycja 9 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja formaldehydu (z obliczen) PB-06 edycja 9 z dnia 01.02.2023 r.","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Formaldehyde emission (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Formaldehyde emission (calculated) Testing Laboratory PB-06 edycja 9 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 甲醛释放量（由计算得出） 检测实验室 PB-06 edycja 9 z dnia 01.02.2023 r.","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"甲醛释放量（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20ddc","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość izocyjanianów - MDI","parameters":[{"name":"Zakres","range":"(0,156 − 250) mg/m3"},{"name":"(0,00625 − 2,5) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość izocyjanianów - MDI\nZakres:\nZakres (0,156 − 250) mg/m3\n(0,00625 − 2,5) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-09 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-09 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość izocyjanianów - MDI\nZakres:\nZakres (0,156 − 250) mg/m3\n(0,00625 − 2,5) mg w próbce\nMetoda spektrofotometryczna PB-09 edycja 7 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc izocyjanianow - MDI\nZakres:\nZakres (0,156 − 250) mg/m3\n(0,00625 − 2,5) mg w probce\nMetoda spektrofotometryczna PB-09 edycja 7 z dnia 01.02.2023 r.","categories":["other"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of isocyanates - MDI","parameters_en":[{"name":"Range","range":"(0,156 − 250) mg/m3"},{"name":"(0,00625 − 2,5) mg in sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Concentration/content of isocyanates - MDI Spectrophotometric method Testing Laboratory Range (0,00625 − 2,5) mg in sample PB-09 edycja 7 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,156 − 250) mg/m3"},{"name":"(0,00625 − 2,5) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 分光光度法 检测实验室 范围 PB-09 edycja 7 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20ddd","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja izocyjanianów - MDI (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja izocyjanianów - MDI (z obliczeń)","reference":"PB-09 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-09 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja izocyjanianów - MDI (z obliczeń) PB-09 edycja 7 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja izocyjanianow - MDI (z obliczen) PB-09 edycja 7 z dnia 01.02.2023 r.","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of isocyanates - MDI (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Emission of isocyanates - MDI (calculated) Testing Laboratory PB-09 edycja 7 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 检测实验室 PB-09 edycja 7 z dnia 01.02.2023 r.","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20dde","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość izocyjanianów - TDI","parameters":[{"name":"Zakres","range":"(0,10 − 320) mg/m3"},{"name":"(0,0040 − 3,2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość izocyjanianów - TDI\nZakres:\nZakres (0,10 − 320) mg/m3\n(0,0040 − 3,2) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-10 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-10 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość izocyjanianów - TDI\nZakres:\nZakres (0,10 − 320) mg/m3\n(0,0040 − 3,2) mg w próbce\nMetoda spektrofotometryczna PB-10 edycja 7 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc izocyjanianow - TDI\nZakres:\nZakres (0,10 − 320) mg/m3\n(0,0040 − 3,2) mg w probce\nMetoda spektrofotometryczna PB-10 edycja 7 z dnia 01.02.2023 r.","categories":["other"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of isocyanates - TDI","parameters_en":[{"name":"Range","range":"(0,10 − 320) mg/m3"},{"name":"(0,0040 − 3,2) mg in sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Concentration/content of isocyanates - TDI Spectrophotometric method Testing Laboratory Range (0,0040 − 3,2) mg in sample PB-10 edycja 7 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,10 − 320) mg/m3"},{"name":"(0,0040 − 3,2) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 分光光度法 检测实验室 范围 PB-10 edycja 7 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20ddf","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja izocyjanianów - TDI (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja izocyjanianów - TDI (z obliczeń)","reference":"PB-10 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-10 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja izocyjanianów - TDI (z obliczeń) PB-10 edycja 7 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja izocyjanianow - TDI (z obliczen) PB-10 edycja 7 z dnia 01.02.2023 r.","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of isocyanates - TDI (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Emission of isocyanates - TDI (calculated) Testing Laboratory PB-10 edycja 7 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 检测实验室 PB-10 edycja 7 z dnia 01.02.2023 r.","test_object_zh":"废气、采集于吸收液的废气样品"},{"_id":"6a83b575af14b9c0e7b20de0","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość kwasu siarkowego","parameters":[{"name":"Zakres","range":"(0,375 − 480) mg/m3"},{"name":"(0,015 − 4,9) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,375 − 480) mg/m3\n(0,015 − 4,9) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-07 edycja 6 z dnia 01.02.2023 r.","norm_bases":["PB-07 edycja 6 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,375 − 480) mg/m3\n(0,015 − 4,9) mg w próbce\nMetoda spektrofotometryczna PB-07 edycja 6 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc kwasu siarkowego\nZakres:\nZakres (0,375 − 480) mg/m3\n(0,015 − 4,9) mg w probce\nMetoda spektrofotometryczna PB-07 edycja 6 z dnia 01.02.2023 r.","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sulfuric acid concentration/content","parameters_en":[{"name":"Range","range":"(0,375 − 480) mg/m3"},{"name":"(0,015 − 4,9) mg in the sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Sulfuric acid concentration/content Spectrophotometric method Testing Laboratory Range (0,015 − 4,9) mg in the sample PB-07 edycja 6 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,375 − 480) mg/m3"},{"name":"(0,015 − 4,9) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 硫酸的浓度/含量 分光光度法 检测实验室 范围 PB-07 edycja 6 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"硫酸的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20de1","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja kwasu siarkowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja kwasu siarkowego (z obliczeń)","reference":"PB-07 edycja 6 z dnia 01.02.2023 r.","norm_bases":["PB-07 edycja 6 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja kwasu siarkowego (z obliczeń) PB-07 edycja 6 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja kwasu siarkowego (z obliczen) PB-07 edycja 6 z dnia 01.02.2023 r.","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sulfuric acid emission (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Sulfuric acid emission (calculated) Testing Laboratory PB-07 edycja 6 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 硫酸排放（由计算得出） 检测实验室 PB-07 edycja 6 z dnia 01.02.2023 r.","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"硫酸排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20de2","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie/zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,075 − 320) mg/m3"},{"name":"(0,0030 − 3,2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,075 − 320) mg/m3\n(0,0030 − 3,2) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-58 edycja 5 z dnia 01.02.2023 r.","norm_bases":["PB-58 edycja 5 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,075 − 320) mg/m3\n(0,0030 − 3,2) mg w próbce\nMetoda spektrofotometryczna PB-58 edycja 5 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie/zawartosc siarkowodoru\nZakres:\nZakres (0,075 − 320) mg/m3\n(0,0030 − 3,2) mg w probce\nMetoda spektrofotometryczna PB-58 edycja 5 z dnia 01.02.2023 r.","categories":["other"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen sulphide concentration/content","parameters_en":[{"name":"Range","range":"(0,075 − 320) mg/m3"},{"name":"(0,0030 − 3,2) mg in the sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Hydrogen sulphide concentration/content Spectrophotometric method Testing Laboratory Range (0,0030 − 3,2) mg in the sample PB-58 edycja 5 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,075 − 320) mg/m3"},{"name":"(0,0030 − 3,2) mg w próbce"}],"search_zh":"废气、采集于吸收液的废气样品 硫化氢的浓度/含量 分光光度法 检测实验室 范围 PB-58 edycja 5 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"硫化氢的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20de3","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja siarkowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja siarkowodoru (z obliczeń)","reference":"PB-58 edycja 5 z dnia 01.02.2023 r.","norm_bases":["PB-58 edycja 5 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja siarkowodoru (z obliczeń) PB-58 edycja 5 z dnia 01.02.2023 r. Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja siarkowodoru (z obliczen) PB-58 edycja 5 z dnia 01.02.2023 r.","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen sulphide emission (calculated)","search_en":"Waste gases, Waste gas samples collected into absorbing solution Hydrogen sulphide emission (calculated) Testing Laboratory PB-58 edycja 5 z dnia 01.02.2023 r.","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 硫化氢排放（由计算得出） 检测实验室 PB-58 edycja 5 z dnia 01.02.2023 r.","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"硫化氢排放（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20de4","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Zawartość metali:","parameters":[{"name":"bar (0,0030 – 0,50) mg w próbce bor (0,0030 – 2,0) mg w próbce bizmut (0,015 – 2,0) mg w próbce cyna (0,015 – 2,0) mg w próbce cynk (0,015 – 50) mg w próbce molibden(0,0030 – 2,0) mg w próbce selen (0,015 – 1,0) mg w próbce tytan (0,015 – 2,0) mg w próbce żelazo (0,010 – 50) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali:\nbar (0,0030 – 0,50) mg w próbce bor (0,0030 – 2,0) mg w próbce bizmut (0,015 – 2,0) mg w próbce cyna (0,015 – 2,0) mg w próbce cynk (0,015 – 50) mg w próbce molibden(0,0030 – 2,0) mg w próbce selen (0,015 – 1,0) mg w próbce tytan (0,015 – 2,0) mg w próbce żelazo (0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych do roztworu pochłaniającego Zawartość metali:\nbar (0,0030 – 0,50) mg w próbce bor (0,0030 – 2,0) mg w próbce bizmut (0,015 – 2,0) mg w próbce cyna (0,015 – 2,0) mg w próbce cynk (0,015 – 50) mg w próbce molibden(0,0030 – 2,0) mg w próbce selen (0,015 – 1,0) mg w próbce tytan (0,015 – 2,0) mg w próbce żelazo (0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2005 Gazy odlotowe, Probki gazow odlotowych pobranych do roztworu pochlaniajacego Zawartosc metali:\nbar (0,0030 – 0,50) mg w probce bor (0,0030 – 2,0) mg w probce bizmut (0,015 – 2,0) mg w probce cyna (0,015 – 2,0) mg w probce cynk (0,015 – 50) mg w probce molibden(0,0030 – 2,0) mg w probce selen (0,015 – 1,0) mg w probce tytan (0,015 – 2,0) mg w probce zelazo (0,010 – 50) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2005","categories":["materials"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Metal content:","parameters_en":[{"name":"barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample selenium (0,015 – 1,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample"}],"search_en":"Waste gases, Waste gas samples collected into absorbing solution Metal content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Testing Laboratory barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample selenium (0,015 – 1,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample PN-EN 14385:2005","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Waste gases, Waste gas samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"废气、采集于吸收液的废气样品 金属含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 检测实验室 PN-EN 14385:2005","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废气、采集于吸收液的废气样品","methodology_zh":"金属含量："},{"_id":"6a83b575af14b9c0e7b20de5","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych na filtry","methodology":"Pobieranie próbek pyłu do oznaczania stężenia metali w pyle (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Pobieranie próbek do oznaczania stężenia metali (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczania stężenia metali w pyle (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Pobieranie próbek do oznaczania stężenia metali (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti)","reference":"PN-Z-04030-7:1994 | PN-EN 14385:2005","norm_bases":["PN-Z-04030-7:1994","PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych na filtry Pobieranie próbek pyłu do oznaczania stężenia metali w pyle (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Pobieranie próbek do oznaczania stężenia metali (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti) PN-Z-04030-7:1994 | PN-EN 14385:2005 Gazy odlotowe, Probki gazow odlotowych pobranych na filtry Pobieranie probek pylu do oznaczania stezenia metali w pyle (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Pobieranie probek do oznaczania stezenia metali (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti) PN-Z-04030-7:1994 | PN-EN 14385:2005","categories":["materials"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust sampling for determination of metal concentrations in dust (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Sampling for determination of metal concentrations (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti)","search_en":"Waste gases, Waste gas samples collected on filters Dust sampling for determination of metal concentrations in dust (Cr, Zn, Cd, Co, Mg, Mn, Cu, Ni, Pb, K, Ag, Fe, Sn, As, Cr, V, Bi, B, Ba, Mo, Se, Ti), Sampling for determination of metal concentrations (Zn, Mg, K, Ag, Fe, Sn, Bi, B, Ba, Mo, Se, Ti) Testing Laboratory PN-Z-04030-7:1994 | PN-EN 14385:2005","test_object_en":"Waste gases, Waste gas samples collected on filters","lab_section_zh":"检测实验室","search_zh":"排放气体、采集在滤膜上的排放气体样品 检测实验室 PN-Z-04030-7:1994 | PN-EN 14385:2005","test_object_zh":"排放气体、采集在滤膜上的排放气体样品"},{"_id":"6a83b575af14b9c0e7b20de6","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych na filtry","methodology":"Stężenie/zawartość metali:","parameters":[{"name":"bor","range":"(0,00030 – 20) mg/m3"},{"name":"Zakres","range":"(0,0030 – 2,0) mg w próbce"},{"name":"bar","range":"(0,00030 – 5,0) mg/m3"},{"name":"(0,0030 – 0,50) mg w próbce bizmut","range":"(0,0015 – 20) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce cyna","range":"(0,0015 – 20) mg mg/m3"},{"name":"(0,015 – 2,0) mg w próbce cynk","range":"(0,0015 – 500) mg/m3"},{"name":"(0,015 – 50) mg w próbce molibden","range":"(0,000030 – 20) mg/m3"},{"name":"(0,00030 – 2,0) mg w próbce selen","range":"(0,0015 – 10) mg/m3"},{"name":"(0,015 – 1,0) mg w próbce tytan","range":"(0,0015 – 20) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce żelazo","range":"(0,0010 – 500) mg/m3"},{"name":"(0,010 – 50) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie/zawartość metali:\nZakres:\nbor (0,00030 – 20) mg/m3\nZakres (0,0030 – 2,0) mg w próbce\nbar (0,00030 – 5,0) mg/m3\n(0,0030 – 0,50) mg w próbce bizmut (0,0015 – 20) mg/m3\n(0,015 – 2,0) mg w próbce cyna (0,0015 – 20) mg mg/m3\n(0,015 – 2,0) mg w próbce cynk (0,0015 – 500) mg/m3\n(0,015 – 50) mg w próbce molibden (0,000030 – 20) mg/m3\n(0,00030 – 2,0) mg w próbce selen (0,0015 – 10) mg/m3\n(0,015 – 1,0) mg w próbce tytan (0,0015 – 20) mg/m3\n(0,015 – 2,0) mg w próbce żelazo (0,0010 – 500) mg/m3\n(0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-Z-04030-7:1994 | PN-EN 14385:2005","norm_bases":["PN-Z-04030-7:1994","PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych na filtry Stężenie/zawartość metali:\nZakres:\nbor (0,00030 – 20) mg/m3\nZakres (0,0030 – 2,0) mg w próbce\nbar (0,00030 – 5,0) mg/m3\n(0,0030 – 0,50) mg w próbce bizmut (0,0015 – 20) mg/m3\n(0,015 – 2,0) mg w próbce cyna (0,0015 – 20) mg mg/m3\n(0,015 – 2,0) mg w próbce cynk (0,0015 – 500) mg/m3\n(0,015 – 50) mg w próbce molibden (0,000030 – 20) mg/m3\n(0,00030 – 2,0) mg w próbce selen (0,0015 – 10) mg/m3\n(0,015 – 1,0) mg w próbce tytan (0,0015 – 20) mg/m3\n(0,015 – 2,0) mg w próbce żelazo (0,0010 – 500) mg/m3\n(0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-Z-04030-7:1994 | PN-EN 14385:2005 Gazy odlotowe, Probki gazow odlotowych pobranych na filtry Stezenie/zawartosc metali:\nZakres:\nbor (0,00030 – 20) mg/m3\nZakres (0,0030 – 2,0) mg w probce\nbar (0,00030 – 5,0) mg/m3\n(0,0030 – 0,50) mg w probce bizmut (0,0015 – 20) mg/m3\n(0,015 – 2,0) mg w probce cyna (0,0015 – 20) mg mg/m3\n(0,015 – 2,0) mg w probce cynk (0,0015 – 500) mg/m3\n(0,015 – 50) mg w probce molibden (0,000030 – 20) mg/m3\n(0,00030 – 2,0) mg w probce selen (0,0015 – 10) mg/m3\n(0,015 – 1,0) mg w probce tytan (0,0015 – 20) mg/m3\n(0,015 – 2,0) mg w probce zelazo (0,0010 – 500) mg/m3\n(0,010 – 50) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-Z-04030-7:1994 | PN-EN 14385:2005","categories":["materials"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Metal concentrations/contents:","parameters_en":[{"name":"boron","range":"(0,00030 – 20) mg/m3"},{"name":"Range","range":"(0,0030 – 2,0) mg w próbce"},{"name":"barium","range":"(0,00030 – 5,0) mg/m3"},{"name":"(0,0030 – 0,50) mg in sample bismuth","range":"(0,0015 – 20) mg/m3"},{"name":"(0,015 – 2,0) mg in the sample tin","range":"(0,0015 – 20) mg mg/m3"},{"name":"(0,015 – 2,0) mg in sample zinc","range":"(0,0015 – 500) mg/m3"},{"name":"(0,015 – 50) mg in the sample molybdenum","range":"(0,000030 – 20) mg/m3"},{"name":"(0,00030 – 2,0) mg in the sample selenium","range":"(0,0015 – 10) mg/m3"},{"name":"(0,015 – 1,0) mg in the sample titanium","range":"(0,0015 – 20) mg/m3"},{"name":"(0,015 – 2,0) mg in the sample iron","range":"(0,0010 – 500) mg/m3"},{"name":"(0,010 – 50) mg in sample"}],"search_en":"Waste gases, Waste gas samples collected on filters Metal concentrations/contents: Inductively coupled plasma optical emission spectrometry (ICP-OES) Testing Laboratory boron Range barium (0,0030 – 0,50) mg in sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in sample zinc (0,015 – 50) mg in the sample molybdenum (0,00030 – 2,0) mg in the sample selenium (0,015 – 1,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in sample PN-Z-04030-7:1994 | PN-EN 14385:2005","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Waste gases, Waste gas samples collected on filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"硼","range":"(0,00030 – 20) mg/m3"},{"name":"范围","range":"(0,0030 – 2,0) mg w próbce"},{"name":"钡","range":"(0,00030 – 5,0) mg/m3"},{"name":"(0,0030 – 0,50) mg w próbce bizmut","range":"(0,0015 – 20) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce cyna","range":"(0,0015 – 20) mg mg/m3"},{"name":"(0,015 – 2,0) mg w próbce cynk","range":"(0,0015 – 500) mg/m3"},{"name":"(0,015 – 50) mg w próbce molibden","range":"(0,000030 – 20) mg/m3"},{"name":"(0,00030 – 2,0) mg w próbce selen","range":"(0,0015 – 10) mg/m3"},{"name":"(0,015 – 1,0) mg w próbce tytan","range":"(0,0015 – 20) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce żelazo","range":"(0,0010 – 500) mg/m3"},{"name":"(0,010 – 50) mg w próbce"}],"search_zh":"排放气体、采集在滤膜上的排放气体样品 金属的浓度/含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 检测实验室 硼 范围 钡 PN-Z-04030-7:1994 | PN-EN 14385:2005","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属的浓度/含量：","test_object_zh":"排放气体、采集在滤膜上的排放气体样品"},{"_id":"6a83b575af14b9c0e7b20de7","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy odlotowe, Próbki gazów odlotowych pobranych na filtry","methodology":"Emisja metali (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 14385:2005","norm_bases":["PN-Z-04030-7:1994","PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe, Próbki gazów odlotowych pobranych na filtry Emisja metali (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (z obliczeń) PN-Z-04030-7:1994 | PN-EN 14385:2005 Gazy odlotowe, Probki gazow odlotowych pobranych na filtry Emisja metali (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (z obliczen) PN-Z-04030-7:1994 | PN-EN 14385:2005","categories":["materials","environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of metals (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (calculated)","search_en":"Waste gases, Waste gas samples collected on filters Emission of metals (B, Ba, Bi, Sn, Zn, Mo, Se, Ti, Fe) (calculated) Testing Laboratory PN-Z-04030-7:1994 | PN-EN 14385:2005","test_object_en":"Waste gases, Waste gas samples collected on filters","lab_section_zh":"检测实验室","search_zh":"排放气体、采集在滤膜上的排放气体样品 检测实验室 PN-Z-04030-7:1994 | PN-EN 14385:2005","test_object_zh":"排放气体、采集在滤膜上的排放气体样品"},{"_id":"6a83b575af14b9c0e7b20de8","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Stężenie metanu, ditlenku węgla, tlenu","parameters":[{"name":"CH4","range":"(0,5 – 70) %"},{"name":"CO2","range":"(0,5 – 60) %"},{"name":"O2","range":"(0,5 – 25) %"}],"technique":"Metoda spektrofotometrii w zakresie podczerwieni; Metoda elektrochemiczna","techniques":["Metoda spektrofotometrii w zakresie podczerwieni","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie metanu, ditlenku węgla, tlenu\nZakres:\nCH4 (0,5 – 70) %\nCO2 (0,5 – 60) %\nO2 (0,5 – 25) %\nMetoda spektrofotometrii w zakresie podczerwieni; Metoda elektrochemiczna","reference":"PB-14 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PB-14 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Stężenie metanu, ditlenku węgla, tlenu\nZakres:\nCH4 (0,5 – 70) %\nCO2 (0,5 – 60) %\nO2 (0,5 – 25) %\nMetoda spektrofotometrii w zakresie podczerwieni; Metoda elektrochemiczna PB-14 edycja 4 z dnia 01.02.2023 r. Gazy skladowiskowe Stezenie metanu, ditlenku wegla, tlenu\nZakres:\nCH4 (0,5 – 70) %\nCO2 (0,5 – 60) %\nO2 (0,5 – 25) %\nMetoda spektrofotometrii w zakresie podczerwieni; Metoda elektrochemiczna PB-14 edycja 4 z dnia 01.02.2023 r.","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of methane, carbon dioxide, oxygen","parameters_en":[{"name":"CH4","range":"(0,5 – 70) %"},{"name":"CO2","range":"(0,5 – 60) %"},{"name":"O2","range":"(0,5 – 25) %"}],"search_en":"Landfill gases Concentration of methane, carbon dioxide, oxygen Infrared spectrophotometry method; Electrochemical method Testing Laboratory CH4 CO2 O2 PB-14 edycja 4 z dnia 01.02.2023 r.","technique_en":"Infrared spectrophotometry method; Electrochemical method","test_object_en":"Landfill gases","lab_section_zh":"检测实验室","search_zh":"填埋场气体 检测实验室 CO2 O2 PB-14 edycja 4 z dnia 01.02.2023 r.","parameters_zh":[{"name":"CH4","range":"(0,5 – 70) %"},{"name":"CO2","range":"(0,5 – 60) %"},{"name":"O2","range":"(0,5 – 25) %"}],"test_object_zh":"填埋场气体"},{"_id":"6a83b575af14b9c0e7b20de9","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Prędkość","parameters":[{"name":"Zakres","range":"(0,5 – 10) m/s"}],"technique":"Metoda anemometryczna","techniques":["Metoda anemometryczna"],"computed":[],"activity":"Prędkość\nZakres (0,5 – 10) m/s\nMetoda anemometryczna","reference":"PB-14 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PB-14 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Prędkość\nZakres (0,5 – 10) m/s\nMetoda anemometryczna PB-14 edycja 4 z dnia 01.02.2023 r. Gazy skladowiskowe Predkosc\nZakres (0,5 – 10) m/s\nMetoda anemometryczna PB-14 edycja 4 z dnia 01.02.2023 r.","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Velocity","parameters_en":[{"name":"Range","range":"(0,5 – 10) m/s"}],"search_en":"Landfill gases Velocity Anemometric method Testing Laboratory Range PB-14 edycja 4 z dnia 01.02.2023 r.","technique_en":"Anemometric method","test_object_en":"Landfill gases","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 10) m/s"}],"search_zh":"填埋场气体 速度 风速仪法 检测实验室 范围 PB-14 edycja 4 z dnia 01.02.2023 r.","test_object_zh":"填埋场气体","methodology_zh":"速度","technique_zh":"风速仪法"},{"_id":"6a83b575af14b9c0e7b20dea","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Emisja metanu, ditlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metanu, ditlenku węgla (z obliczeń)","reference":"PB-14 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PB-14 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Emisja metanu, ditlenku węgla (z obliczeń) PB-14 edycja 4 z dnia 01.02.2023 r. Gazy skladowiskowe Emisja metanu, ditlenku wegla (z obliczen) PB-14 edycja 4 z dnia 01.02.2023 r.","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Emission of methane, carbon dioxide (calculated)","search_en":"Landfill gases Emission of methane, carbon dioxide (calculated) Testing Laboratory PB-14 edycja 4 z dnia 01.02.2023 r.","test_object_en":"Landfill gases","lab_section_zh":"检测实验室","search_zh":"填埋场气体 检测实验室 PB-14 edycja 4 z dnia 01.02.2023 r.","test_object_zh":"填埋场气体"},{"_id":"6a83b575af14b9c0e7b20deb","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Stężenie tlenku węgla (CO)","parameters":[{"name":"Zakres","range":"(2,5 – 500) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenku węgla (CO)\nZakres (2,5 – 500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PB-02 edycja 6 z dnia 17.03.2025 r.","norm_bases":["PB-02 edycja 6 z dnia 17.03.2025 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie tlenku węgla (CO)\nZakres (2,5 – 500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PB-02 edycja 6 z dnia 17.03.2025 r. Srodowisko ogolne − powietrze atmosferyczne Stezenie tlenku wegla (CO)\nZakres (2,5 – 500) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PB-02 edycja 6 z dnia 17.03.2025 r.","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Carbon monoxide (CO) concentration","parameters_en":[{"name":"Range","range":"(2,5 – 500) mg/m3"}],"search_en":"General environment − ambient air Carbon monoxide (CO) concentration Non-dispersive infrared spectrometry (NDIR) Testing Laboratory Range PB-02 edycja 6 z dnia 17.03.2025 r.","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(2,5 – 500) mg/m3"}],"search_zh":"一般环境 － 大气空气 非分散红外光谱法（NDIR） 检测实验室 范围 PB-02 edycja 6 z dnia 17.03.2025 r.","technique_zh":"非分散红外光谱法（NDIR）","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83b575af14b9c0e7b20dec","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Stężenie lotnych związków organicznych (LZO) wyrażone jako całkowity węgiel organiczny (TOC)","parameters":[{"name":"Zakres","range":"(1 – 100) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie lotnych związków organicznych (LZO) wyrażone jako całkowity węgiel organiczny (TOC)\nZakres (1 – 100) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PB-30 edycja 6 z dnia 17.03.2025 r.","norm_bases":["PB-30 edycja 6 z dnia 17.03.2025 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie lotnych związków organicznych (LZO) wyrażone jako całkowity węgiel organiczny (TOC)\nZakres (1 – 100) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PB-30 edycja 6 z dnia 17.03.2025 r. Srodowisko ogolne − powietrze atmosferyczne Stezenie lotnych zwiazkow organicznych (LZO) wyrazone jako calkowity wegiel organiczny (TOC)\nZakres (1 – 100) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PB-30 edycja 6 z dnia 17.03.2025 r.","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Volatile organic compounds (VOC) concentration expressed as total organic carbon (TOC)","parameters_en":[{"name":"Range","range":"(1 – 100) mg/m3"}],"search_en":"General environment − ambient air Volatile organic compounds (VOC) concentration expressed as total organic carbon (TOC) Continuous flame ionization detection method (FID) Testing Laboratory Range PB-30 edycja 6 z dnia 17.03.2025 r.","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1 – 100) mg/m3"}],"search_zh":"一般环境 － 大气空气 连续火焰离子化检测法（FID） 检测实验室 范围 PB-30 edycja 6 z dnia 17.03.2025 r.","test_object_zh":"一般环境 － 大气空气","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a83b575af14b9c0e7b20ded","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Pobieranie próbek pyłu do badań","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do badań","reference":"PB-01 edycja 6 z dnia 21.02.2025 r.","norm_bases":["PB-01 edycja 6 z dnia 21.02.2025 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Pobieranie próbek pyłu do badań PB-01 edycja 6 z dnia 21.02.2025 r. Srodowisko ogolne − powietrze atmosferyczne Pobieranie probek pylu do badan PB-01 edycja 6 z dnia 21.02.2025 r.","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust sampling for testing","search_en":"General environment − ambient air Dust sampling for testing Testing Laboratory PB-01 edycja 6 z dnia 21.02.2025 r.","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 用于检验的粉尘采样 检测实验室 PB-01 edycja 6 z dnia 21.02.2025 r.","test_object_zh":"一般环境 － 大气空气","methodology_zh":"用于检验的粉尘采样"},{"_id":"6a83b575af14b9c0e7b20dee","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,0055 – 10) mg/m3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,0055 – 10) mg/m3\nMetoda wagowa","reference":"PB-01 edycja 6 z dnia 21.02.2025 r.","norm_bases":["PB-01 edycja 6 z dnia 21.02.2025 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Stężenie pyłu\nZakres (0,0055 – 10) mg/m3\nMetoda wagowa PB-01 edycja 6 z dnia 21.02.2025 r. Srodowisko ogolne − powietrze atmosferyczne Stezenie pylu\nZakres (0,0055 – 10) mg/m3\nMetoda wagowa PB-01 edycja 6 z dnia 21.02.2025 r.","categories":["environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,0055 – 10) mg/m3"}],"search_en":"General environment − ambient air Dust concentration Gravimetric method Testing Laboratory Range PB-01 edycja 6 z dnia 21.02.2025 r.","technique_en":"Gravimetric method","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0055 – 10) mg/m3"}],"search_zh":"一般环境 － 大气空气 粉尘浓度 重量法 检测实验室 范围 PB-01 edycja 6 z dnia 21.02.2025 r.","technique_zh":"重量法","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83b575af14b9c0e7b20def","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Pobieranie próbek do oznaczania stężenia: amoniaku, chloru, chlorowodoru, fluoru i jego związków, formaldehydu, izocyjanianów – MDI, TDI, kwasu siarkowego, siarkowodoru","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia: amoniaku, chloru, chlorowodoru, fluoru i jego związków, formaldehydu, izocyjanianów – MDI, TDI, kwasu siarkowego, siarkowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"PB-16A edycja 2 z dnia 01.02.2023 r.","norm_bases":["PB-16A edycja 2 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Pobieranie próbek do oznaczania stężenia: amoniaku, chloru, chlorowodoru, fluoru i jego związków, formaldehydu, izocyjanianów – MDI, TDI, kwasu siarkowego, siarkowodoru\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających PB-16A edycja 2 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne Pobieranie probek do oznaczania stezenia: amoniaku, chloru, chlorowodoru, fluoru i jego zwiazkow, formaldehydu, izocyjanianow – MDI, TDI, kwasu siarkowego, siarkowodoru\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych PB-16A edycja 2 z dnia 01.02.2023 r.","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the concentration of: ammonia, chlorine, hydrogen chloride, fluorine and its compounds, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide","search_en":"General environment − ambient air Sampling for determination of the concentration of: ammonia, chlorine, hydrogen chloride, fluorine and its compounds, formaldehyde, isocyanates – MDI, TDI, sulfuric acid, hydrogen sulfide Aspiration method using absorbing solutions Testing Laboratory PB-16A edycja 2 z dnia 01.02.2023 r.","technique_en":"Aspiration method using absorbing solutions","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 采用吸收液的抽气法 检测实验室 PB-16A edycja 2 z dnia 01.02.2023 r.","technique_zh":"采用吸收液的抽气法","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83b575af14b9c0e7b20df0","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Pobieranie próbek do oznaczenia stężenia związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego, silikażelu, chromosorbu, XAD-2","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego, silikażelu, chromosorbu, XAD-2"],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego, silikażelu, chromosorbu, XAD-2","reference":"PB-16A edycja 2 z dnia 01.02.2023 r.","norm_bases":["PB-16A edycja 2 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Pobieranie próbek do oznaczenia stężenia związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego, silikażelu, chromosorbu, XAD-2 PB-16A edycja 2 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne Pobieranie probek do oznaczenia stezenia zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego, silikazelu, chromosorbu, XAD-2 PB-16A edycja 2 z dnia 01.02.2023 r.","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for the determination of organic compound concentration","search_en":"General environment − ambient air Sampling for the determination of organic compound concentration Aspiration method using activated carbon, silica gel, chromosorb, XAD-2 Testing Laboratory PB-16A edycja 2 z dnia 01.02.2023 r.","technique_en":"Aspiration method using activated carbon, silica gel, chromosorb, XAD-2","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 用于测定有机化合物浓度的采样 检测实验室 PB-16A edycja 2 z dnia 01.02.2023 r.","test_object_zh":"一般环境 － 大气空气","methodology_zh":"用于测定有机化合物浓度的采样"},{"_id":"6a83b575af14b9c0e7b20df1","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Pobieranie próbek do oznaczania stężenia związków siarkoorganicznych i metanu","parameters":[],"technique":"Metoda izolacyjna z zastosowaniem worków tedlarowych","techniques":["Metoda izolacyjna z zastosowaniem worków tedlarowych"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia związków siarkoorganicznych i metanu\nMetoda izolacyjna z zastosowaniem worków tedlarowych","reference":"PB-61 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PB-61 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Pobieranie próbek do oznaczania stężenia związków siarkoorganicznych i metanu\nMetoda izolacyjna z zastosowaniem worków tedlarowych PB-61 edycja 4 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne Pobieranie probek do oznaczania stezenia zwiazkow siarkoorganicznych i metanu\nMetoda izolacyjna z zastosowaniem workow tedlarowych PB-61 edycja 4 z dnia 01.02.2023 r.","categories":["environment","construction"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of the concentration of organosulfur compounds and methane","search_en":"General environment − ambient air Sampling for determination of the concentration of organosulfur compounds and methane Isolation method using Tedlar bags Testing Laboratory PB-61 edycja 4 z dnia 01.02.2023 r.","technique_en":"Isolation method using Tedlar bags","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 检测实验室 PB-61 edycja 4 z dnia 01.02.2023 r.","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83b575af14b9c0e7b20df2","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Pobieranie próbek pyłu zawieszonego, PM10 lub PM2,5","parameters":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"computed":[],"activity":"Pobieranie próbek pyłu zawieszonego, PM10 lub PM2,5\nMetoda aspiracyjna","reference":"PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5","norm_bases":["PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Pobieranie próbek pyłu zawieszonego, PM10 lub PM2,5\nMetoda aspiracyjna PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5 Srodowisko ogolne − powietrze atmosferyczne Pobieranie probek pylu zawieszonego, PM10 lub PM2,5\nMetoda aspiracyjna PN-EN 12341:2014 z wylaczeniem pkt. 5.2, 6.2, 6.4, 6.5","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling of suspended particulate matter, PM10 or PM2,5","search_en":"General environment − ambient air Sampling of suspended particulate matter, PM10 or PM2,5 Aspiration method Testing Laboratory PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5","technique_en":"Aspiration method","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 抽气法 检测实验室 PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5","technique_zh":"抽气法","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83b575af14b9c0e7b20df3","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne","methodology":"Pobieranie próbek pyłu PM10 i PM2,5 do oznaczania stężenia metali: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn","parameters":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"computed":[],"activity":"Pobieranie próbek pyłu PM10 i PM2,5 do oznaczania stężenia metali: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn\nMetoda aspiracyjna","reference":"PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5","norm_bases":["PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne Pobieranie próbek pyłu PM10 i PM2,5 do oznaczania stężenia metali: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn\nMetoda aspiracyjna PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5 Srodowisko ogolne − powietrze atmosferyczne Pobieranie probek pylu PM10 i PM2,5 do oznaczania stezenia metali: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn\nMetoda aspiracyjna PN-EN 12341:2014 z wylaczeniem pkt. 5.2, 6.2, 6.4, 6.5","categories":["materials","environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling of PM10 and PM2,5 dust for determination of metal concentrations: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn","search_en":"General environment − ambient air Sampling of PM10 and PM2,5 dust for determination of metal concentrations: As, Ba, B, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Sn, Ti, V, Zn Aspiration method Testing Laboratory PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5","technique_en":"Aspiration method","test_object_en":"General environment − ambient air","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 抽气法 检测实验室 PN-EN 12341:2014 z wyłączeniem pkt. 5.2, 6.2, 6.4, 6.5","technique_zh":"抽气法","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83b575af14b9c0e7b20df4","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,25 − 400) mg/m3"},{"name":"(0,010 − 8) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (0,25 − 400) mg/m3\n(0,010 − 8) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-11 edycja 9 z dnia 01.02.2023 r.","norm_bases":["PB-11 edycja 9 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość amoniaku\nZakres:\nZakres (0,25 − 400) mg/m3\n(0,010 − 8) mg w próbce\nMetoda spektrofotometryczna PB-11 edycja 9 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc amoniaku\nZakres:\nZakres (0,25 − 400) mg/m3\n(0,010 − 8) mg w probce\nMetoda spektrofotometryczna PB-11 edycja 9 z dnia 01.02.2023 r.","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(0,25 − 400) mg/m3"},{"name":"(0,010 − 8) mg in the sample"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Ammonia concentration/content Spectrophotometric method Testing Laboratory Range (0,010 − 8) mg in the sample PB-11 edycja 9 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,25 − 400) mg/m3"},{"name":"(0,010 − 8) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 氨浓度/含量 分光光度法 检测实验室 范围 PB-11 edycja 9 z dnia 01.02.2023 r.","technique_zh":"分光光度法","methodology_zh":"氨浓度/含量","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20df5","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość chloru","parameters":[{"name":"Zakres","range":"(0,05 – 0,5) mg/m3"},{"name":"(0,002 − 0,014) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,05 – 0,5) mg/m3\n(0,002 − 0,014) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-13 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-13 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość chloru\nZakres:\nZakres (0,05 – 0,5) mg/m3\n(0,002 − 0,014) mg w próbce\nMetoda spektrofotometryczna PB-13 edycja 7 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc chloru\nZakres:\nZakres (0,05 – 0,5) mg/m3\n(0,002 − 0,014) mg w probce\nMetoda spektrofotometryczna PB-13 edycja 7 z dnia 01.02.2023 r.","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Chlorine concentration/content","parameters_en":[{"name":"Range","range":"(0,05 – 0,5) mg/m3"},{"name":"(0,002 − 0,014) mg in sample"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Chlorine concentration/content Spectrophotometric method Testing Laboratory Range (0,002 − 0,014) mg in sample PB-13 edycja 7 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,05 – 0,5) mg/m3"},{"name":"(0,002 − 0,014) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 氯的浓度/含量 分光光度法 检测实验室 范围 PB-13 edycja 7 z dnia 01.02.2023 r.","technique_zh":"分光光度法","methodology_zh":"氯的浓度/含量","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20df6","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,5 - 10) mg/m3"},{"name":"Zakres","range":"(0,02 – 4,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 - 10) mg/m3\nZakres (0,02 – 4,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-12 edycja 6 z dnia 01.02.2023 r.","norm_bases":["PB-12 edycja 6 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 - 10) mg/m3\nZakres (0,02 – 4,0) mg w próbce\nMetoda spektrofotometryczna PB-12 edycja 6 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,5 - 10) mg/m3\nZakres (0,02 – 4,0) mg w probce\nMetoda spektrofotometryczna PB-12 edycja 6 z dnia 01.02.2023 r.","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,5 - 10) mg/m3"},{"name":"Range","range":"(0,02 – 4,0) mg w próbce"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Hydrogen chloride concentration/content Spectrophotometric method Testing Laboratory Range Range PB-12 edycja 6 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,5 - 10) mg/m3"},{"name":"范围","range":"(0,02 – 4,0) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 氯化氢的浓度/含量 分光光度法 检测实验室 范围 范围 PB-12 edycja 6 z dnia 01.02.2023 r.","technique_zh":"分光光度法","methodology_zh":"氯化氢的浓度/含量","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20df7","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość fluoru i jego związków","parameters":[{"name":"Zakres","range":"(0,1 − 4000) mg/m3"},{"name":"(0,0040 − 20) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie/zawartość fluoru i jego związków\nZakres:\nZakres (0,1 − 4000) mg/m3\n(0,0040 − 20) mg w próbce\nMetoda potencjometryczna","reference":"PB-15 edycja 6 z dnia 01.02.2023 r.","norm_bases":["PB-15 edycja 6 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość fluoru i jego związków\nZakres:\nZakres (0,1 − 4000) mg/m3\n(0,0040 − 20) mg w próbce\nMetoda potencjometryczna PB-15 edycja 6 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc fluoru i jego zwiazkow\nZakres:\nZakres (0,1 − 4000) mg/m3\n(0,0040 − 20) mg w probce\nMetoda potencjometryczna PB-15 edycja 6 z dnia 01.02.2023 r.","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of fluorine and its compounds","parameters_en":[{"name":"Range","range":"(0,1 − 4000) mg/m3"},{"name":"(0,0040 − 20) mg in sample"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Concentration/content of fluorine and its compounds Potentiometric method Testing Laboratory Range (0,0040 − 20) mg in sample PB-15 edycja 6 z dnia 01.02.2023 r.","technique_en":"Potentiometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,1 − 4000) mg/m3"},{"name":"(0,0040 − 20) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 电位法 检测实验室 范围 PB-15 edycja 6 z dnia 01.02.2023 r.","technique_zh":"电位法","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20df8","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,025 − 40) mg/m3"},{"name":"(0,0010 − 0,8) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,025 − 40) mg/m3\n(0,0010 − 0,8) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-06 edycja 9 z dnia 01.02.2023 r.","norm_bases":["PB-06 edycja 9 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,025 − 40) mg/m3\n(0,0010 − 0,8) mg w próbce\nMetoda spektrofotometryczna PB-06 edycja 9 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,025 − 40) mg/m3\n(0,0010 − 0,8) mg w probce\nMetoda spektrofotometryczna PB-06 edycja 9 z dnia 01.02.2023 r.","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,025 − 40) mg/m3"},{"name":"(0,0010 − 0,8) mg in the sample"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Formaldehyde concentration/content Spectrophotometric method Testing Laboratory Range (0,0010 − 0,8) mg in the sample PB-06 edycja 9 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,025 − 40) mg/m3"},{"name":"(0,0010 − 0,8) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 甲醛浓度/含量 分光光度法 检测实验室 范围 PB-06 edycja 9 z dnia 01.02.2023 r.","technique_zh":"分光光度法","methodology_zh":"甲醛浓度/含量","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20df9","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość izocyjanianów - MDI","parameters":[{"name":"Zakres","range":"(0,156 − 125) mg/m3"},{"name":"(0,00625 − 2,5) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość izocyjanianów - MDI\nZakres:\nZakres (0,156 − 125) mg/m3\n(0,00625 − 2,5) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-09 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-09 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość izocyjanianów - MDI\nZakres:\nZakres (0,156 − 125) mg/m3\n(0,00625 − 2,5) mg w próbce\nMetoda spektrofotometryczna PB-09 edycja 7 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc izocyjanianow - MDI\nZakres:\nZakres (0,156 − 125) mg/m3\n(0,00625 − 2,5) mg w probce\nMetoda spektrofotometryczna PB-09 edycja 7 z dnia 01.02.2023 r.","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of isocyanates - MDI","parameters_en":[{"name":"Range","range":"(0,156 − 125) mg/m3"},{"name":"(0,00625 − 2,5) mg in sample"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Concentration/content of isocyanates - MDI Spectrophotometric method Testing Laboratory Range (0,00625 − 2,5) mg in sample PB-09 edycja 7 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,156 − 125) mg/m3"},{"name":"(0,00625 − 2,5) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 分光光度法 检测实验室 范围 PB-09 edycja 7 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20dfa","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość izocyjanianów - TDI","parameters":[{"name":"Zakres","range":"(0,100 − 250) mg/m3"},{"name":"(0,0040 − 3,2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość izocyjanianów - TDI\nZakres:\nZakres (0,100 − 250) mg/m3\n(0,0040 − 3,2) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-10 edycja 7 z dnia 01.02.2023 r.","norm_bases":["PB-10 edycja 7 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość izocyjanianów - TDI\nZakres:\nZakres (0,100 − 250) mg/m3\n(0,0040 − 3,2) mg w próbce\nMetoda spektrofotometryczna PB-10 edycja 7 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc izocyjanianow - TDI\nZakres:\nZakres (0,100 − 250) mg/m3\n(0,0040 − 3,2) mg w probce\nMetoda spektrofotometryczna PB-10 edycja 7 z dnia 01.02.2023 r.","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of isocyanates - TDI","parameters_en":[{"name":"Range","range":"(0,100 − 250) mg/m3"},{"name":"(0,0040 − 3,2) mg in sample"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Concentration/content of isocyanates - TDI Spectrophotometric method Testing Laboratory Range (0,0040 − 3,2) mg in sample PB-10 edycja 7 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,100 − 250) mg/m3"},{"name":"(0,0040 − 3,2) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 分光光度法 检测实验室 范围 PB-10 edycja 7 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20dfb","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość kwasu siarkowego","parameters":[{"name":"Zakres","range":"(0,375 − 120) mg/m3"},{"name":"Zakres","range":"(0,015 – 2,45) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,375 − 120) mg/m3\nZakres (0,015 – 2,45) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-07 edycja 6 z dnia 01.02.2023 r.","norm_bases":["PB-07 edycja 6 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość kwasu siarkowego\nZakres:\nZakres (0,375 − 120) mg/m3\nZakres (0,015 – 2,45) mg w próbce\nMetoda spektrofotometryczna PB-07 edycja 6 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc kwasu siarkowego\nZakres:\nZakres (0,375 − 120) mg/m3\nZakres (0,015 – 2,45) mg w probce\nMetoda spektrofotometryczna PB-07 edycja 6 z dnia 01.02.2023 r.","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sulfuric acid concentration/content","parameters_en":[{"name":"Range","range":"(0,375 − 120) mg/m3"},{"name":"Range","range":"(0,015 – 2,45) mg w próbce"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Sulfuric acid concentration/content Spectrophotometric method Testing Laboratory Range Range PB-07 edycja 6 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,375 − 120) mg/m3"},{"name":"范围","range":"(0,015 – 2,45) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 硫酸的浓度/含量 分光光度法 检测实验室 范围 范围 PB-07 edycja 6 z dnia 01.02.2023 r.","technique_zh":"分光光度法","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品","methodology_zh":"硫酸的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20dfc","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,019 − 0,5) mg/m3"},{"name":"(0,0015 − 0,010) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,019 − 0,5) mg/m3\n(0,0015 − 0,010) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-58 edycja 5 z dnia 01.02.2023 r.","norm_bases":["PB-58 edycja 5 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,019 − 0,5) mg/m3\n(0,0015 − 0,010) mg w próbce\nMetoda spektrofotometryczna PB-58 edycja 5 z dnia 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc siarkowodoru\nZakres:\nZakres (0,019 − 0,5) mg/m3\n(0,0015 − 0,010) mg w probce\nMetoda spektrofotometryczna PB-58 edycja 5 z dnia 01.02.2023 r.","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Hydrogen sulphide concentration/content","parameters_en":[{"name":"Range","range":"(0,019 − 0,5) mg/m3"},{"name":"(0,0015 − 0,010) mg in the sample"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Hydrogen sulphide concentration/content Spectrophotometric method Testing Laboratory Range (0,0015 − 0,010) mg in the sample PB-58 edycja 5 z dnia 01.02.2023 r.","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,019 − 0,5) mg/m3"},{"name":"(0,0015 − 0,010) mg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 硫化氢的浓度/含量 分光光度法 检测实验室 范围 PB-58 edycja 5 z dnia 01.02.2023 r.","technique_zh":"分光光度法","methodology_zh":"硫化氢的浓度/含量","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20dfd","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia NO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia NO2","reference":"PN-Z-04009-9:1997","norm_bases":["PN-Z-04009-9:1997"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia NO2 PN-Z-04009-9:1997 Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia NO2 PN-Z-04009-9:1997","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of NO2 concentration","search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Sampling for determination of NO2 concentration Testing Laboratory PN-Z-04009-9:1997","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 检测实验室 PN-Z-04009-9:1997","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20dfe","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość NO2","parameters":[{"name":"Zakres","range":"(12,6 – 6285) μg/m3"},{"name":"Zakres","range":"(0,40 – 200) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość NO2\nZakres:\nZakres (12,6 – 6285) μg/m3\nZakres (0,40 – 200) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-9:1997","norm_bases":["PN-Z-04009-9:1997"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość NO2\nZakres:\nZakres (12,6 – 6285) μg/m3\nZakres (0,40 – 200) μg w próbce\nMetoda spektrofotometryczna PN-Z-04009-9:1997 Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc NO2\nZakres:\nZakres (12,6 – 6285) μg/m3\nZakres (0,40 – 200) μg w probce\nMetoda spektrofotometryczna PN-Z-04009-9:1997","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"NO2 concentration/content","parameters_en":[{"name":"Range","range":"(12,6 – 6285) μg/m3"},{"name":"Range","range":"(0,40 – 200) μg w próbce"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution NO2 concentration/content Spectrophotometric method Testing Laboratory Range Range PN-Z-04009-9:1997","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(12,6 – 6285) μg/m3"},{"name":"范围","range":"(0,40 – 200) μg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 分光光度法 检测实验室 范围 范围 PN-Z-04009-9:1997","technique_zh":"分光光度法","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20dff","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia SO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-ISO 6767:1997","norm_bases":["PN-ISO 6767:1997"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia SO2 PN-ISO 6767:1997 Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia SO2 PN-ISO 6767:1997","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for determination of SO2 concentration","search_en":"General environment − ambient air – ambient air samples collected into absorbing solution Sampling for determination of SO2 concentration Testing Laboratory PN-ISO 6767:1997","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 用于测定 SO2 浓度的采样 检测实验室 PN-ISO 6767:1997","methodology_zh":"用于测定 SO2 浓度的采样","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20e00","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość SO2","parameters":[{"name":"Zakres","range":"(26,7 – 853) μg/m3"},{"name":"Zakres","range":"(1,6 – 25,6) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość SO2\nZakres:\nZakres (26,7 – 853) μg/m3\nZakres (1,6 – 25,6) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-ISO 6767:1997","norm_bases":["PN-ISO 6767:1997"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Stężenie/zawartość SO2\nZakres:\nZakres (26,7 – 853) μg/m3\nZakres (1,6 – 25,6) μg w próbce\nMetoda spektrofotometryczna PN-ISO 6767:1997 Srodowisko ogolne − powietrze atmosferyczne – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Stezenie/zawartosc SO2\nZakres:\nZakres (26,7 – 853) μg/m3\nZakres (1,6 – 25,6) μg w probce\nMetoda spektrofotometryczna PN-ISO 6767:1997","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"SO2 concentration/content","parameters_en":[{"name":"Range","range":"(26,7 – 853) μg/m3"},{"name":"Range","range":"(1,6 – 25,6) μg w próbce"}],"search_en":"General environment − ambient air – ambient air samples collected into absorbing solution SO2 concentration/content Spectrophotometric method Testing Laboratory Range Range PN-ISO 6767:1997","technique_en":"Spectrophotometric method","test_object_en":"General environment − ambient air – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(26,7 – 853) μg/m3"},{"name":"范围","range":"(1,6 – 25,6) μg w próbce"}],"search_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品 分光光度法 检测实验室 范围 范围 PN-ISO 6767:1997","technique_zh":"分光光度法","test_object_zh":"一般环境 － 大气空气 － 采集于吸收液中的大气空气样品"},{"_id":"6a83b575af14b9c0e7b20e01","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne − próbki powietrza atmosferycznego pobrane na rurki z sorbentem","methodology":"Stężenie/zawartość związków organicznych","parameters":[{"name":"Zakres","range":"1,2,4-trimetylobenzen"},{"name":"Zakres","range":"(0,00260 – 125) mg/m3"},{"name":"Zakres","range":"(0,0050 – 10) mg w próbce"},{"name":"aceton","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce akroleina","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce alkohol diacetonowy","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce benzen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butyloglikol","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 20) mg w próbce chlorek metylenu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksan","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Cykloheksanon","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce epichlorohydryna","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etylobenzen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce fenol","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan butylobenzylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan dietylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dibutylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dimetylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dioktylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce heksan","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izobutanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izopropanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość związków organicznych\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,00260 – 125) mg/m3\nZakres (0,0050 – 10) mg w próbce\naceton (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce akroleina (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce alkohol diacetonowy (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce benzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce butanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce butyloglikol (0,00260 – 25) mg/m3\n(0,0050 – 20) mg w próbce chlorek metylenu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce cykloheksan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce cykloheksanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce Cykloheksanon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce epichlorohydryna (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce etanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce etylobenzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce fenol (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan butylobenzylu (0,00260 – 25) mg/m3\n(0,0050-2) mg w próbce ftalan dietylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan dibutylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan dimetylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan dioktylu (0,00260 – 25) mg/m3\n(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce heksan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce izobutanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce izopropanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-05 edycja 12 z dn. 01.02.2023 r.","norm_bases":["PB-05 edycja 12 z dn. 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne − próbki powietrza atmosferycznego pobrane na rurki z sorbentem Stężenie/zawartość związków organicznych\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,00260 – 125) mg/m3\nZakres (0,0050 – 10) mg w próbce\naceton (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce akroleina (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce alkohol diacetonowy (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce benzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce butanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce butyloglikol (0,00260 – 25) mg/m3\n(0,0050 – 20) mg w próbce chlorek metylenu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce cykloheksan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce cykloheksanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce Cykloheksanon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce epichlorohydryna (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce etanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce etylobenzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce fenol (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan butylobenzylu (0,00260 – 25) mg/m3\n(0,0050-2) mg w próbce ftalan dietylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan dibutylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan dimetylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce ftalan dioktylu (0,00260 – 25) mg/m3\n(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w próbce heksan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce izobutanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce izopropanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-05 edycja 12 z dn. 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne − probki powietrza atmosferycznego pobrane na rurki z sorbentem Stezenie/zawartosc zwiazkow organicznych\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,00260 – 125) mg/m3\nZakres (0,0050 – 10) mg w probce\naceton (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce akroleina (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w probce alkohol diacetonowy (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce benzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce butanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce butyloglikol (0,00260 – 25) mg/m3\n(0,0050 – 20) mg w probce chlorek metylenu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce cykloheksan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce cykloheksanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce Cykloheksanon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce epichlorohydryna (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce etanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce etylobenzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce fenol (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w probce ftalan butylobenzylu (0,00260 – 25) mg/m3\n(0,0050-2) mg w probce ftalan dietylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w probce ftalan dibutylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w probce ftalan dimetylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w probce ftalan dioktylu (0,00260 – 25) mg/m3\n(0,0050-2) mg w probce ftalan bis-2-etyloheksylu (0,00260 – 25) mg/m3\n(0,0050 – 2) mg w probce heksan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce izobutanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce izopropanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-05 edycja 12 z dn. 01.02.2023 r.","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of organic compounds","parameters_en":[{"name":"Range","range":"1,2,4-trimetylobenzen"},{"name":"Range","range":"(0,00260 – 125) mg/m3"},{"name":"Range","range":"(0,0050 – 10) mg w próbce"},{"name":"acetone","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample acrolein","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg in sample diacetone alcohol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample benzene","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample butanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample butyl glycol","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 20) mg in sample methylene chloride","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample cyclohexane","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample cyclohexanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in the sample Cyclohexanone","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample epichlorohydrin","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample ethanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample ethylbenzene","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample phenol","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg in sample benzyl butyl phthalate","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050-2) mg in sample diethyl phthalate","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg in sample dibutyl phthalate","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg in sample dimethyl phthalate","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg in sample dioctyl phthalate","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050-2) mg in sample bis(2-ethylhexyl) phthalate","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg in sample hexane","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample isobutanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample isopropanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in the sample"}],"search_en":"General environment − ambient air − ambient air samples collected on sorbent tubes Concentration/content of organic compounds Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory Range Range Range acetone (0,0050 – 10) mg in sample acrolein (0,0050 – 2) mg in sample diacetone alcohol (0,0050 – 10) mg in sample benzene (0,0050 – 10) mg in sample butanol (0,0050 – 10) mg in sample butyl glycol (0,0050 – 20) mg in sample methylene chloride (0,0050 – 10) mg in sample cyclohexane (0,0050 – 10) mg in sample cyclohexanol (0,0050 – 10) mg in the sample Cyclohexanone (0,0050 – 10) mg in sample epichlorohydrin (0,0050 – 10) mg in sample ethanol (0,0050 – 10) mg in sample ethylbenzene (0,0050 – 10) mg in sample phenol (0,0050 – 2) mg in sample benzyl butyl phthalate (0,0050-2) mg in sample diethyl phthalate (0,0050 – 2) mg in sample dibutyl phthalate (0,0050 – 2) mg in sample dimethyl phthalate (0,0050 – 2) mg in sample dioctyl phthalate (0,0050-2) mg in sample bis(2-ethylhexyl) phthalate (0,0050 – 2) mg in sample hexane (0,0050 – 10) mg in sample isobutanol (0,0050 – 10) mg in sample isopropanol (0,0050 – 10) mg in the sample PB-05 edycja 12 z dn. 01.02.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment − ambient air − ambient air samples collected on sorbent tubes","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"1,2,4-trimetylobenzen"},{"name":"范围","range":"(0,00260 – 125) mg/m3"},{"name":"范围","range":"(0,0050 – 10) mg w próbce"},{"name":"丙酮","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce akroleina","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce alkohol diacetonowy","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce benzen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce butyloglikol","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 20) mg w próbce chlorek metylenu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksan","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce cykloheksanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce Cykloheksanon","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce epichlorohydryna","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce etylobenzen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce fenol","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan butylobenzylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan dietylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dibutylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dimetylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce ftalan dioktylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050-2) mg w próbce ftalan bis-2-etyloheksylu","range":"(0,00260 – 25) mg/m3"},{"name":"(0,0050 – 2) mg w próbce heksan","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izobutanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce izopropanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg/样品"}],"search_zh":"有机化合物的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 范围 范围 范围 丙酮 (0,0050 – 10) mg/样品 PB-05 edycja 12 z dn. 01.02.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"有机化合物的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20e02","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − powietrze atmosferyczne − próbki powietrza atmosferycznego pobrane na rurki z sorbentem","methodology":"Stężenie/zawartość związków organicznych","parameters":[{"name":"ksylen","range":"(0,00260 – 125) mg/m3"},{"name":"Zakres","range":"(0,0050 – 10) mg w próbce"},{"name":"kumen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce kwas octowy","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metakrylan metylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloetyloketon","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloizobutyloketon","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce mezytylen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan butylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan etylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan metylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan winylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce pentan","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce propylobenzen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce styren","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce toluen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory alifatyczne","range":"(suma C5 - C12)"},{"name":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma)","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość związków organicznych\nZakres:\nksylen (0,00260 – 125) mg/m3\nZakres (0,0050 – 10) mg w próbce\nkumen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce kwas octowy (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metakrylan metylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metyloetyloketon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metyloizobutyloketon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce mezytylen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan butylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan etylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan metylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan winylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce pentan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce propylobenzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce styren (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce toluen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce węglowodory alifatyczne (suma C5 - C12)\n(0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma) (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-05 edycja 12 z dn. 01.02.2023 r.","norm_bases":["PB-05 edycja 12 z dn. 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − powietrze atmosferyczne − próbki powietrza atmosferycznego pobrane na rurki z sorbentem Stężenie/zawartość związków organicznych\nZakres:\nksylen (0,00260 – 125) mg/m3\nZakres (0,0050 – 10) mg w próbce\nkumen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce kwas octowy (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metakrylan metylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metyloetyloketon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce metyloizobutyloketon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce mezytylen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan butylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan etylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan metylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce octan winylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce pentan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce propylobenzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce styren (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce toluen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce węglowodory alifatyczne (suma C5 - C12)\n(0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma) (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-05 edycja 12 z dn. 01.02.2023 r. Srodowisko ogolne − powietrze atmosferyczne − probki powietrza atmosferycznego pobrane na rurki z sorbentem Stezenie/zawartosc zwiazkow organicznych\nZakres:\nksylen (0,00260 – 125) mg/m3\nZakres (0,0050 – 10) mg w probce\nkumen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce kwas octowy (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce metakrylan metylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce metanol (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce metyloetyloketon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce metyloizobutyloketon (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce mezytylen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce octan butylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce octan etylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce octan metylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce octan winylu (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce pentan (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce propylobenzen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce styren (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce toluen (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce weglowodory alifatyczne (suma C5 - C12)\n(0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce weglowodory aromatyczne (suma) (0,00260 – 125) mg/m3\n(0,0050 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-05 edycja 12 z dn. 01.02.2023 r.","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration/content of organic compounds","parameters_en":[{"name":"xylene","range":"(0,00260 – 125) mg/m3"},{"name":"Range","range":"(0,0050 – 10) mg w próbce"},{"name":"cumene","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in the sample acetic acid","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl methacrylate","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample methanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl ethyl ketone","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl isobutyl ketone","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample mesitylene","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample butyl acetate","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample ethyl acetate","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample methyl acetate","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample vinyl acetate","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample pentane","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample propylbenzene","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample styrene","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample toluene","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample aliphatic hydrocarbons","range":"(suma C5 - C12)"},{"name":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in sample aromatic hydrocarbons (sum)","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg in the sample"}],"search_en":"General environment − ambient air − ambient air samples collected on sorbent tubes Concentration/content of organic compounds Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory xylene Range cumene (0,0050 – 10) mg in the sample acetic acid (0,0050 – 10) mg in sample methyl methacrylate (0,0050 – 10) mg in sample methanol (0,0050 – 10) mg in sample methyl ethyl ketone (0,0050 – 10) mg in sample methyl isobutyl ketone (0,0050 – 10) mg in sample mesitylene (0,0050 – 10) mg in sample butyl acetate (0,0050 – 10) mg in sample ethyl acetate (0,0050 – 10) mg in sample methyl acetate (0,0050 – 10) mg in sample vinyl acetate (0,0050 – 10) mg in sample pentane (0,0050 – 10) mg in sample propylbenzene (0,0050 – 10) mg in sample styrene (0,0050 – 10) mg in sample toluene (0,0050 – 10) mg in sample aliphatic hydrocarbons (0,00260 – 125) mg/m3 (0,0050 – 10) mg in sample aromatic hydrocarbons (sum) (0,0050 – 10) mg in the sample PB-05 edycja 12 z dn. 01.02.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment − ambient air − ambient air samples collected on sorbent tubes","lab_section_zh":"检测实验室","parameters_zh":[{"name":"ksylen","range":"(0,00260 – 125) mg/m3"},{"name":"范围","range":"(0,0050 – 10) mg w próbce"},{"name":"异丙苯","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce kwas octowy","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metakrylan metylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metanol","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloetyloketon","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce metyloizobutyloketon","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce mezytylen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan butylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan etylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan metylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce octan winylu","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce pentan","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce propylobenzen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce styren","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce toluen","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory alifatyczne","range":"(suma C5 - C12)"},{"name":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg w próbce węglowodory aromatyczne (suma)","range":"(0,00260 – 125) mg/m3"},{"name":"(0,0050 – 10) mg/样品"}],"search_zh":"有机化合物的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 范围 异丙苯 (0,0050 – 10) mg/样品 PB-05 edycja 12 z dn. 01.02.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"有机化合物的浓度/含量"},{"_id":"6a83b575af14b9c0e7b20e03","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze atmosferyczne – próbki powietrza atmosferycznego pobranego na filtry","methodology":"Stężenie / zawartość metali","parameters":[{"name":"antymon","range":"(0,00030 – 0,56) mg/m3"},{"name":"Zakres","range":"(0,0030 – 2,0) mg w próbce"},{"name":"arsen","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce bor","range":"(0,00030 – 0,56) mg/m3"},{"name":"(0,0030 – 2,0) mg w próbce bar","range":"(0,00030 – 0,14) mg/m3"},{"name":"(0,0030 – 0,50) mg w próbce bizmut","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce chrom","range":"(0,00030 – 47,2) mg/m3"},{"name":"(0,0030 – 170) mg w próbce cyna","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce cynk","range":"(0,00150 – 13,9) mg/m3"},{"name":"(0,015 – 50) mg w próbce kadm","range":"(0,000015 – 0,28) mg/m3"},{"name":"(0,00015 – 1,0) mg w próbce kobalt","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce mangan","range":"(0,00030 – 0,56) mg/m3"},{"name":"(0,0030 – 2,0) mg w próbce miedź","range":"(0,00030 – 0,97) mg/m3"},{"name":"(0,0030 – 3,50) mg w próbce molibden","range":"(0,000030 – 0,56) mg/m3"},{"name":"(0,00030 – 2,0) mg w próbce nikiel","range":"(0,00030 – 4,2) mg/m3"},{"name":"(0,0030 – 150) mg w próbce ołów","range":"(0,00030 – 13,9) mg/m3"},{"name":"(0,0030 – 50) mg w próbce tytan","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce wanad","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce żelazo","range":"(0,0010 – 13,9) mg/m3"},{"name":"(0,010 – 50) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie / zawartość metali\nZakres:\nantymon (0,00030 – 0,56) mg/m3\nZakres (0,0030 – 2,0) mg w próbce\narsen (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w próbce bor (0,00030 – 0,56) mg/m3\n(0,0030 – 2,0) mg w próbce bar (0,00030 – 0,14) mg/m3\n(0,0030 – 0,50) mg w próbce bizmut (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w próbce chrom (0,00030 – 47,2) mg/m3\n(0,0030 – 170) mg w próbce cyna (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w próbce cynk (0,00150 – 13,9) mg/m3\n(0,015 – 50) mg w próbce kadm (0,000015 – 0,28) mg/m3\n(0,00015 – 1,0) mg w próbce kobalt (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w próbce mangan (0,00030 – 0,56) mg/m3\n(0,0030 – 2,0) mg w próbce miedź (0,00030 – 0,97) mg/m3\n(0,0030 – 3,50) mg w próbce molibden (0,000030 – 0,56) mg/m3\n(0,00030 – 2,0) mg w próbce nikiel (0,00030 – 4,2) mg/m3\n(0,0030 – 150) mg w próbce ołów (0,00030 – 13,9) mg/m3\n(0,0030 – 50) mg w próbce tytan (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w próbce wanad (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w próbce żelazo (0,0010 – 13,9) mg/m3\n(0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-60 edycja 3 z dnia 01.02.2023 r.","norm_bases":["PB-60 edycja 3 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – powietrze atmosferyczne – próbki powietrza atmosferycznego pobranego na filtry Stężenie / zawartość metali\nZakres:\nantymon (0,00030 – 0,56) mg/m3\nZakres (0,0030 – 2,0) mg w próbce\narsen (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w próbce bor (0,00030 – 0,56) mg/m3\n(0,0030 – 2,0) mg w próbce bar (0,00030 – 0,14) mg/m3\n(0,0030 – 0,50) mg w próbce bizmut (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w próbce chrom (0,00030 – 47,2) mg/m3\n(0,0030 – 170) mg w próbce cyna (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w próbce cynk (0,00150 – 13,9) mg/m3\n(0,015 – 50) mg w próbce kadm (0,000015 – 0,28) mg/m3\n(0,00015 – 1,0) mg w próbce kobalt (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w próbce mangan (0,00030 – 0,56) mg/m3\n(0,0030 – 2,0) mg w próbce miedź (0,00030 – 0,97) mg/m3\n(0,0030 – 3,50) mg w próbce molibden (0,000030 – 0,56) mg/m3\n(0,00030 – 2,0) mg w próbce nikiel (0,00030 – 4,2) mg/m3\n(0,0030 – 150) mg w próbce ołów (0,00030 – 13,9) mg/m3\n(0,0030 – 50) mg w próbce tytan (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w próbce wanad (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w próbce żelazo (0,0010 – 13,9) mg/m3\n(0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-60 edycja 3 z dnia 01.02.2023 r. Srodowisko ogolne – powietrze atmosferyczne – probki powietrza atmosferycznego pobranego na filtry Stezenie / zawartosc metali\nZakres:\nantymon (0,00030 – 0,56) mg/m3\nZakres (0,0030 – 2,0) mg w probce\narsen (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w probce bor (0,00030 – 0,56) mg/m3\n(0,0030 – 2,0) mg w probce bar (0,00030 – 0,14) mg/m3\n(0,0030 – 0,50) mg w probce bizmut (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w probce chrom (0,00030 – 47,2) mg/m3\n(0,0030 – 170) mg w probce cyna (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w probce cynk (0,00150 – 13,9) mg/m3\n(0,015 – 50) mg w probce kadm (0,000015 – 0,28) mg/m3\n(0,00015 – 1,0) mg w probce kobalt (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w probce mangan (0,00030 – 0,56) mg/m3\n(0,0030 – 2,0) mg w probce miedz (0,00030 – 0,97) mg/m3\n(0,0030 – 3,50) mg w probce molibden (0,000030 – 0,56) mg/m3\n(0,00030 – 2,0) mg w probce nikiel (0,00030 – 4,2) mg/m3\n(0,0030 – 150) mg w probce olow (0,00030 – 13,9) mg/m3\n(0,0030 – 50) mg w probce tytan (0,00150 – 0,56) mg/m3\n(0,015 – 2,0) mg w probce wanad (0,000015 – 0,56) mg/m3\n(0,00015 – 2,0) mg w probce zelazo (0,0010 – 13,9) mg/m3\n(0,010 – 50) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-60 edycja 3 z dnia 01.02.2023 r.","categories":["materials","environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration / content of metals","parameters_en":[{"name":"antimony","range":"(0,00030 – 0,56) mg/m3"},{"name":"Range","range":"(0,0030 – 2,0) mg w próbce"},{"name":"arsenic","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg in the sample boron","range":"(0,00030 – 0,56) mg/m3"},{"name":"(0,0030 – 2,0) mg in the sample barium","range":"(0,00030 – 0,14) mg/m3"},{"name":"(0,0030 – 0,50) mg in sample bismuth","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg in the sample chromium","range":"(0,00030 – 47,2) mg/m3"},{"name":"(0,0030 – 170) mg in the sample tin","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg in sample zinc","range":"(0,00150 – 13,9) mg/m3"},{"name":"(0,015 – 50) mg in the sample cadmium","range":"(0,000015 – 0,28) mg/m3"},{"name":"(0,00015 – 1,0) mg in sample cobalt","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg in sample manganese","range":"(0,00030 – 0,56) mg/m3"},{"name":"(0,0030 – 2,0) mg in sample copper","range":"(0,00030 – 0,97) mg/m3"},{"name":"(0,0030 – 3,50) mg in the sample molybdenum","range":"(0,000030 – 0,56) mg/m3"},{"name":"(0,00030 – 2,0) mg in the sample nickel","range":"(0,00030 – 4,2) mg/m3"},{"name":"(0,0030 – 150) mg in the sample lead","range":"(0,00030 – 13,9) mg/m3"},{"name":"(0,0030 – 50) mg in the sample titanium","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg in the sample vanadium","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg in the sample iron","range":"(0,0010 – 13,9) mg/m3"},{"name":"(0,010 – 50) mg in sample"}],"search_en":"General environment – ambient air – ambient air samples collected on filters Concentration / content of metals Inductively coupled plasma optical emission spectrometry (ICP-OES) Testing Laboratory antimony Range arsenic (0,00015 – 2,0) mg in the sample boron (0,0030 – 2,0) mg in the sample barium (0,0030 – 0,50) mg in sample bismuth (0,015 – 2,0) mg in the sample chromium (0,0030 – 170) mg in the sample tin (0,015 – 2,0) mg in sample zinc (0,015 – 50) mg in the sample cadmium (0,00015 – 1,0) mg in sample cobalt (0,00015 – 2,0) mg in sample manganese (0,0030 – 2,0) mg in sample copper (0,0030 – 3,50) mg in the sample molybdenum (0,00030 – 2,0) mg in the sample nickel (0,0030 – 150) mg in the sample lead (0,0030 – 50) mg in the sample titanium (0,015 – 2,0) mg in the sample vanadium (0,00015 – 2,0) mg in the sample iron (0,010 – 50) mg in sample PB-60 edycja 3 z dnia 01.02.2023 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"General environment – ambient air – ambient air samples collected on filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"锑","range":"(0,00030 – 0,56) mg/m3"},{"name":"范围","range":"(0,0030 – 2,0) mg w próbce"},{"name":"砷","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce bor","range":"(0,00030 – 0,56) mg/m3"},{"name":"(0,0030 – 2,0) mg w próbce bar","range":"(0,00030 – 0,14) mg/m3"},{"name":"(0,0030 – 0,50) mg w próbce bizmut","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce chrom","range":"(0,00030 – 47,2) mg/m3"},{"name":"(0,0030 – 170) mg w próbce cyna","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce cynk","range":"(0,00150 – 13,9) mg/m3"},{"name":"(0,015 – 50) mg w próbce kadm","range":"(0,000015 – 0,28) mg/m3"},{"name":"(0,00015 – 1,0) mg w próbce kobalt","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce mangan","range":"(0,00030 – 0,56) mg/m3"},{"name":"(0,0030 – 2,0) mg w próbce miedź","range":"(0,00030 – 0,97) mg/m3"},{"name":"(0,0030 – 3,50) mg w próbce molibden","range":"(0,000030 – 0,56) mg/m3"},{"name":"(0,00030 – 2,0) mg w próbce nikiel","range":"(0,00030 – 4,2) mg/m3"},{"name":"(0,0030 – 150) mg w próbce ołów","range":"(0,00030 – 13,9) mg/m3"},{"name":"(0,0030 – 50) mg w próbce tytan","range":"(0,00150 – 0,56) mg/m3"},{"name":"(0,015 – 2,0) mg w próbce wanad","range":"(0,000015 – 0,56) mg/m3"},{"name":"(0,00015 – 2,0) mg w próbce żelazo","range":"(0,0010 – 13,9) mg/m3"},{"name":"(0,010 – 50) mg w próbce"}],"search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 检测实验室 锑 范围 砷 PB-60 edycja 3 z dnia 01.02.2023 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83b575af14b9c0e7b20e04","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane na na filtry – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego","methodology":"Zawartość metali:","parameters":[{"name":"antymon (0,0030 – 2,0) mg w próbce arsen (0,00030 – 2,0) mg w próbce bar (0,0030 – 0,50) mg w próbce bor (0,0030 – 2,0) mg w próbce bizmut (0,015 – 2,0) mg w próbce cyna (0,015 – 2,0) mg w próbce cynk (0,015 – 50) mg w próbce chrom (0,0030 – 170) mg w próbce kadm (0,00015 – 1,0) mg w próbce kobalt (0,00015 – 2,0) mg w próbce mangan (0,0030 – 2,0) mg w próbce miedź (0,0030 – 3,5) mg w próbce molibden(0,0030 – 2,0) mg w próbce nikiel (0,0030 – 15) mg w próbce ołów (0,0030 – 50) mg w próbce selen (0,015 – 1,0) mg w próbce wanad (0,00015 – 2,0) mg w próbce tytan (0,015 – 2,0) mg w próbce żelazo (0,010 – 50) mg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali:\nantymon (0,0030 – 2,0) mg w próbce arsen (0,00030 – 2,0) mg w próbce bar (0,0030 – 0,50) mg w próbce bor (0,0030 – 2,0) mg w próbce bizmut (0,015 – 2,0) mg w próbce cyna (0,015 – 2,0) mg w próbce cynk (0,015 – 50) mg w próbce chrom (0,0030 – 170) mg w próbce kadm (0,00015 – 1,0) mg w próbce kobalt (0,00015 – 2,0) mg w próbce mangan (0,0030 – 2,0) mg w próbce miedź (0,0030 – 3,5) mg w próbce molibden(0,0030 – 2,0) mg w próbce nikiel (0,0030 – 15) mg w próbce ołów (0,0030 – 50) mg w próbce selen (0,015 – 1,0) mg w próbce wanad (0,00015 – 2,0) mg w próbce tytan (0,015 – 2,0) mg w próbce żelazo (0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – powietrze atmosferyczne – próbki powietrza atmosferycznego pobrane na na filtry – próbki powietrza atmosferycznego pobrane do roztworu pochłaniającego Zawartość metali:\nantymon (0,0030 – 2,0) mg w próbce arsen (0,00030 – 2,0) mg w próbce bar (0,0030 – 0,50) mg w próbce bor (0,0030 – 2,0) mg w próbce bizmut (0,015 – 2,0) mg w próbce cyna (0,015 – 2,0) mg w próbce cynk (0,015 – 50) mg w próbce chrom (0,0030 – 170) mg w próbce kadm (0,00015 – 1,0) mg w próbce kobalt (0,00015 – 2,0) mg w próbce mangan (0,0030 – 2,0) mg w próbce miedź (0,0030 – 3,5) mg w próbce molibden(0,0030 – 2,0) mg w próbce nikiel (0,0030 – 15) mg w próbce ołów (0,0030 – 50) mg w próbce selen (0,015 – 1,0) mg w próbce wanad (0,00015 – 2,0) mg w próbce tytan (0,015 – 2,0) mg w próbce żelazo (0,010 – 50) mg w próbce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2005 Srodowisko ogolne – powietrze atmosferyczne – probki powietrza atmosferycznego pobrane na na filtry – probki powietrza atmosferycznego pobrane do roztworu pochlaniajacego Zawartosc metali:\nantymon (0,0030 – 2,0) mg w probce arsen (0,00030 – 2,0) mg w probce bar (0,0030 – 0,50) mg w probce bor (0,0030 – 2,0) mg w probce bizmut (0,015 – 2,0) mg w probce cyna (0,015 – 2,0) mg w probce cynk (0,015 – 50) mg w probce chrom (0,0030 – 170) mg w probce kadm (0,00015 – 1,0) mg w probce kobalt (0,00015 – 2,0) mg w probce mangan (0,0030 – 2,0) mg w probce miedz (0,0030 – 3,5) mg w probce molibden(0,0030 – 2,0) mg w probce nikiel (0,0030 – 15) mg w probce olow (0,0030 – 50) mg w probce selen (0,015 – 1,0) mg w probce wanad (0,00015 – 2,0) mg w probce tytan (0,015 – 2,0) mg w probce zelazo (0,010 – 50) mg w probce\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2005","categories":["materials","environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Metal content:","parameters_en":[{"name":"antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample selenium (0,015 – 1,0) mg in the sample vanadium (0,00015 – 2,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample"}],"search_en":"General environment – ambient air – ambient air samples collected on filters – ambient air samples collected into absorbing solution Metal content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Testing Laboratory antimony (0,0030 – 2,0) mg in the sample arsenic (0,00030 – 2,0) mg in the sample barium (0,0030 – 0,50) mg in the sample boron (0,0030 – 2,0) mg in the sample bismuth (0,015 – 2,0) mg in the sample tin (0,015 – 2,0) mg in the sample zinc (0,015 – 50) mg in the sample chromium (0,0030 – 170) mg in the sample cadmium (0,00015 – 1,0) mg in the sample cobalt (0,00015 – 2,0) mg in the sample manganese (0,0030 – 2,0) mg in the sample copper (0,0030 – 3,5) mg in the sample molybdenum(0,0030 – 2,0) mg in the sample nickel (0,0030 – 15) mg in the sample lead (0,0030 – 50) mg in the sample selenium (0,015 – 1,0) mg in the sample vanadium (0,00015 – 2,0) mg in the sample titanium (0,015 – 2,0) mg in the sample iron (0,010 – 50) mg in the sample PN-EN 14385:2005","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"General environment – ambient air – ambient air samples collected on filters – ambient air samples collected into absorbing solution","lab_section_zh":"检测实验室","search_zh":"金属含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 检测实验室 PN-EN 14385:2005","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属含量："},{"_id":"6a83b575af14b9c0e7b20e05","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) oC","reference":"PN-ISO 5667-10:1997 | PB-32 edycja 4 z dnia 01.02.2023 r.","norm_bases":["PN-ISO 5667-10:1997","PB-32 edycja 4 z dnia 01.02.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) oC PN-ISO 5667-10:1997 | PB-32 edycja 4 z dnia 01.02.2023 r. Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,0 – 50,0) oC PN-ISO 5667-10:1997 | PB-32 edycja 4 z dnia 01.02.2023 r.","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) oC"}],"search_en":"Rainwater and snowmelt water Sampling for chemical and physical testing Temperature of the water sample taken Testing Laboratory Range PN-ISO 5667-10:1997 | PB-32 edycja 4 z dnia 01.02.2023 r.","test_object_en":"Rainwater and snowmelt water","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"雨水与融雪水 化学和物理检测采样 所采水样的温度 检测实验室 范围 PN-ISO 5667-10:1997 | PB-32 edycja 4 z dnia 01.02.2023 r.","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"雨水与融雪水"},{"_id":"6a83b575af14b9c0e7b20e06","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Indeks oleju mineralnego C10 – C40 (węglowodory ropopochodne)","parameters":[{"name":"Zakres","range":"(0,60 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego C10 – C40 (węglowodory ropopochodne)\nZakres (0,60 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Indeks oleju mineralnego C10 – C40 (węglowodory ropopochodne)\nZakres (0,60 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Wody opadowe i roztopowe Indeks oleju mineralnego C10 – C40 (weglowodory ropopochodne)\nZakres (0,60 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Mineral oil index C10 – C40 (petroleum hydrocarbons)","parameters_en":[{"name":"Range","range":"(0,60 – 50) mg/l"}],"search_en":"Rainwater and snowmelt water Mineral oil index C10 – C40 (petroleum hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Rainwater and snowmelt water","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,60 – 50) mg/l"}],"search_zh":"雨水与融雪水 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"雨水与融雪水"},{"_id":"6a83b575af14b9c0e7b20e07","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Testing Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater and snowmelt water","lab_section_zh":"检测实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"雨水与融雪水 总悬浮物 重量法 检测实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水与融雪水"},{"_id":"6a83b575af14b9c0e7b20e08","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 137) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 137) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 检测实验室 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a83b575af14b9c0e7b20e09","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Testing Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","test_object_en":"General environment − noise from installations, equipment and industrial plants","lab_section_zh":"检测实验室","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 检测实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a83b575af14b9c0e7b20e0a","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Metoda obliczeniowa","reference":"PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)","norm_bases":["PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Metoda obliczeniowa PN-ISO 9613-2:2002 CNOSSOS-EU (Industry) Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Metoda obliczeniowa PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"General environment − noise from installations, equipment and industrial plants Calculation method Testing Laboratory PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)","technique_en":"Calculation method","test_object_en":"General environment − noise from installations, equipment and industrial plants","lab_section_zh":"检测实验室","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 计算法 检测实验室 PN-ISO 9613-2:2002 CNOSSOS-EU (Industry)","technique_zh":"计算法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a83b575af14b9c0e7b20e0b","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","norm_bases":["Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","PN-ISO 1996-2:1999+A1:2002"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002 Srodowisko ogolne − halas impulsowy pochodzacy od instalacji i urzadzen Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25 – 137) dB"}],"search_en":"General environment − impulse noise from installations and equipment A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Testing Laboratory Range Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","technique_en":"Direct measurement method","test_object_en":"General environment − impulse noise from installations and equipment","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(25 – 137) dB"}],"search_zh":"一般环境 － 来自装置与设备的脉冲噪声 A 计权等效声级 A 计权声暴露级 直接测量法 检测实验室 范围 Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 － 来自装置与设备的脉冲噪声"},{"_id":"6a83b575af14b9c0e7b20e0c","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","norm_bases":["Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706)","PN-ISO 1996-2:1999+A1:2002"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji i urządzeń Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002 Srodowisko ogolne − halas impulsowy pochodzacy od instalacji i urzadzen Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − impulse noise from installations and equipment A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Testing Laboratory Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","test_object_en":"General environment − impulse noise from installations and equipment","lab_section_zh":"检测实验室","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置与设备的脉冲噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 检测实验室 Załącznik nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) | PN-ISO 1996-2:1999+A1:2002","test_object_zh":"一般环境 － 来自装置与设备的脉冲噪声"},{"_id":"6a83b575af14b9c0e7b20e0d","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Maszyny i urządzenia − hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011+Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011+Ap1:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia − hałas Równoważny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011+Ap1:2017-09 Maszyny i urzadzenia − halas Rownowazny poziom dzwieku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011+Ap1:2017-09","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 137) dB"}],"search_en":"Machinery and equipment − noise A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range PN-EN ISO 3746:2011+Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment − noise","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 137) dB"}],"search_zh":"机器与设备 － 噪声 A 计权等效声级 直接测量法 检测实验室 范围 PN-EN ISO 3746:2011+Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 － 噪声"},{"_id":"6a83b575af14b9c0e7b20e0e","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Maszyny i urządzenia − hałas","methodology":"Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011+Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011+Ap1:2017-09"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia − hałas Poziom mocy akustycznej, Poziom energii akustycznej (z obliczeń) PN-EN ISO 3746:2011+Ap1:2017-09 Maszyny i urzadzenia − halas Poziom mocy akustycznej, Poziom energii akustycznej (z obliczen) PN-EN ISO 3746:2011+Ap1:2017-09","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Sound power level, Sound energy level (calculated)","search_en":"Machinery and equipment − noise Sound power level, Sound energy level (calculated) Testing Laboratory PN-EN ISO 3746:2011+Ap1:2017-09","test_object_en":"Machinery and equipment − noise","lab_section_zh":"检测实验室","search_zh":"机器与设备 － 噪声 声功率级、声能量级（由计算得出） 检测实验室 PN-EN ISO 3746:2011+Ap1:2017-09","test_object_zh":"机器与设备 － 噪声","methodology_zh":"声功率级、声能量级（由计算得出）"},{"_id":"6a83b575af14b9c0e7b20e0f","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne – ekrany akustyczne „in situ”","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 − 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 − 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-ISO 10847:2002","norm_bases":["PN-ISO 10847:2002"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – ekrany akustyczne „in situ” Równoważny poziom dźwięku A\nZakres (25 − 137) dB\nMetoda pomiarowa bezpośrednia PN-ISO 10847:2002 Srodowisko ogolne – ekrany akustyczne „in situ” Rownowazny poziom dzwieku A\nZakres (25 − 137) dB\nMetoda pomiarowa bezposrednia PN-ISO 10847:2002","categories":["environment"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 − 137) dB"}],"search_en":"General environment – noise barriers „in situ” A-weighted equivalent sound pressure level Direct measurement method Testing Laboratory Range PN-ISO 10847:2002","technique_en":"Direct measurement method","test_object_en":"General environment – noise barriers „in situ”","lab_section_zh":"检测实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 − 137) dB"}],"search_zh":"一般环境 － 声屏障「现场」 A 计权等效声级 直接测量法 检测实验室 范围 PN-ISO 10847:2002","technique_zh":"直接测量法","test_object_zh":"一般环境 － 声屏障「现场」"},{"_id":"6a83b575af14b9c0e7b20e10","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne – ekrany akustyczne „in situ”","methodology":"Skuteczność ekranów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność ekranów (z obliczeń)","reference":"PN-ISO 10847:2002","norm_bases":["PN-ISO 10847:2002"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – ekrany akustyczne „in situ” Skuteczność ekranów (z obliczeń) PN-ISO 10847:2002 Srodowisko ogolne – ekrany akustyczne „in situ” Skutecznosc ekranow (z obliczen) PN-ISO 10847:2002","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Effectiveness of screens (calculated)","search_en":"General environment – noise barriers „in situ” Effectiveness of screens (calculated) Testing Laboratory PN-ISO 10847:2002","test_object_en":"General environment – noise barriers „in situ”","lab_section_zh":"检测实验室","search_zh":"一般环境 － 声屏障「现场」 屏蔽效能（由计算得出） 检测实验室 PN-ISO 10847:2002","methodology_zh":"屏蔽效能（由计算得出）","test_object_zh":"一般环境 － 声屏障「现场」"},{"_id":"6a83b575af14b9c0e7b20e11","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25 – 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25 – 137) dB"}],"search_en":"General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Testing Laboratory Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","technique_en":"Direct measurement method","test_object_en":"General environment − noise from roads, railway lines, tram lines","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(25 – 137) dB"}],"search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 检测实验室 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a83b575af14b9c0e7b20e12","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Testing Laboratory Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","test_object_en":"General environment − noise from roads, railway lines, tram lines","lab_section_zh":"检测实验室","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 检测实验室 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697)","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a83b575af14b9c0e7b20e13","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Metoda obliczeniowa","reference":"NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)","norm_bases":["NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Metoda obliczeniowa NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail) Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Metoda obliczeniowa NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","search_en":"General environment − noise from roads, railway lines, tram lines Calculation method Testing Laboratory NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)","technique_en":"Calculation method","test_object_en":"General environment − noise from roads, railway lines, tram lines","lab_section_zh":"检测实验室","search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 计算法 检测实验室 NMBP-Roads-1996/NFS 31-133 (XPS 31-133) NMPB-Roads-2008 CNOSSOS-EU (Road) RMR/SRM II CNOSSOS-EU (Rail)","technique_zh":"计算法","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a83b575af14b9c0e7b20e14","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 −137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 −137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","norm_bases":["Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od lotnisk Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (25 −137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824) Srodowisko ogolne − halas pochodzacy od lotnisk Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (25 −137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 1 i nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","categories":["environment"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(25 −137) dB"}],"search_en":"General environment − noise from airports A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Testing Laboratory Range Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","technique_en":"Direct measurement method","test_object_en":"General environment − noise from airports","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(25 −137) dB"}],"search_zh":"一般环境 － 来自机场的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 检测实验室 范围 Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 － 来自机场的噪声"},{"_id":"6a83b575af14b9c0e7b20e15","lab_id":"69ad52a3de79e566650fb498","country":"PL","accr_number":"AB 912","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","norm_bases":["Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od lotnisk Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824) Srodowisko ogolne − halas pochodzacy od lotnisk Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 1 i nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","categories":["environment"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from airports A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Testing Laboratory Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","test_object_en":"General environment − noise from airports","lab_section_zh":"检测实验室","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自机场的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 检测实验室 Załącznik nr 1 i nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. 2011 nr 140, poz. 824)","test_object_zh":"一般环境 － 来自机场的噪声"}],"has_pdf":true}