{"lab":{"_id":"69ad52a3de79e566650fb496","accr_number":"AB 911","country":"PL","accr_body":"PCA","address":"ul. Sikorskiego 108 A, 84-200 Wejherowo, LABORATORIUM, ul. Rybacka 24 uż 4","categories":["water"],"city":"Wejherowo","imported_at":"2026-03-08T10:42:43.265Z","methods_count":39,"name":"COVER Krystyna Pawlak","parse_status":"parsed","parse_version":2,"pdf_files":["AB_911.pdf"],"scope_summary":"","search_text":"cover krystyna pawlak ul. sikorskiego 108 a, 84-200 wejherowo, laboratorium, ul. rybacka 24 uż 4 water microbiology pharma electronics other","status":"active","updated_at":"2026-03-08T14:51:48.400Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:48.400Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20911,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P, N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"P/28, P/29","pl":"Pobieranie próbek wody, wody do spożycia przez ludzi do badań mikrobiologicznych","en":"Sampling of water, drinking water for microbiological testing"}],"issue":{"no":"19","date":"28.05.2025"},"parse_date":"2026-07-20T07:09:54.262Z","parse_source":"script-pdfplumber","map_coord":[54.601026,18.272555],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":39,"microbiology":1},"category_scores":{"water":38.03,"microbiology":0.03},"has_zh":true},"methods":[{"_id":"6a5dc9c2f1c10c8ce825f8d3","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych","methodology_en":"Water sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek wody do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek wody do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Water sampling for chemical and physical testing PN-ISO 5667-5:2017-10","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8d4","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych","methodology_en":"Water sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5, 7.6, 8.2, 9.4. | PN-ISO 5667-11:2017-10 z wyłączeniem 5.2, 6.2, 6.3.","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5, 7.6, 8.2, 9.4.","PN-ISO 5667-11:2017-10 z wyłączeniem 5.2, 6.2, 6.3."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek wody do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5, 7.6, 8.2, 9.4. | PN-ISO 5667-11:2017-10 z wyłączeniem 5.2, 6.2, 6.3. Woda Pobieranie probek wody do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem 7.5, 7.6, 8.2, 9.4. | PN-ISO 5667-11:2017-10 z wylaczeniem 5.2, 6.2, 6.3.","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Water sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5, 7.6, 8.2, 9.4. | PN-ISO 5667-11:2017-10 z wyłączeniem 5.2, 6.2, 6.3.","search_zh":"水 PN-EN ISO 5667-6:2016-12 z wyłączeniem 7.5, 7.6, 8.2, 9.4. | PN-ISO 5667-11:2017-10 z wyłączeniem 5.2, 6.2, 6.3.","test_object_zh":"水"},{"_id":"6a5dc9c2f1c10c8ce825f8d5","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8d6","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(20 − 1999) μS/cm"}],"parameters_en":[{"name":"Range","range":"(20 − 1999) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (20 − 1999) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (20 − 1999) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (20 − 1999) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(20 − 1999) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8d7","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 − 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 − 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 − 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 − 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 − 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 − 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8d8","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Twardość ogólna","methodology_en":"Total hardness","parameters":[{"name":"Zakres","range":"(0,05 − 5,0) mmol/l"},{"name":"(5 − 500) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,05 − 5,0) mmol/l"},{"name":"(5 − 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Twardość ogólna\nZakres:\nZakres (0,05 − 5,0) mmol/l\n(5 − 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (0,05 − 5,0) mmol/l\n(5 − 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (0,05 − 5,0) mmol/l\n(5 − 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total hardness Titrimetric method Range (5 − 500) mg/l CaCO3 PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(0,05 − 5,0) mmol/l"},{"name":"(5 − 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 总硬度 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"总硬度"},{"_id":"6a5dc9c2f1c10c8ce825f8d9","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(0,05 − 2,5) mmol/l"},{"name":"(2 − 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 − 2,5) mmol/l"},{"name":"(2 − 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres:\nZakres (0,05 − 2,5) mmol/l\n(2 − 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres:\nZakres (0,05 − 2,5) mmol/l\n(2 − 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres:\nZakres (0,05 − 2,5) mmol/l\n(2 − 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Range (2 − 100) mg/l PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(0,05 − 2,5) mmol/l"},{"name":"(2 − 100) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9c2f1c10c8ce825f8da","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,010 − 0,500) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 − 0,500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,010 − 0,500) mg/l\nMetoda spektrofotometryczna","reference":"PB-02 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8149","norm_bases":["PB-02 wydanie 3 z dnia 05.05.2021 r.","na podstawie testu Hach-Lange nr 8149"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 − 0,500) mg/l\nMetoda spektrofotometryczna PB-02 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8149 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 − 0,500) mg/l\nMetoda spektrofotometryczna PB-02 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8149","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PB-02 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8149","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 − 0,500) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PB-02 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8149","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8db","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,040 – 0,60) mg/l P-PO43-"},{"name":"Zakres","range":"(0,120 – 1,80) mg/l PO43-"}],"parameters_en":[{"name":"Range","range":"(0,040 – 0,60) mg/l P-PO43-"},{"name":"Range","range":"(0,120 – 1,80) mg/l PO43-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres:\nZakres (0,040 – 0,60) mg/l P-PO43-\nZakres (0,120 – 1,80) mg/l PO43-\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 rozdział 4","norm_bases":["PN-EN ISO 6878:2006 rozdział 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie ortofosforanów\nZakres:\nZakres (0,040 – 0,60) mg/l P-PO43-\nZakres (0,120 – 1,80) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdział 4 Woda, woda do spozycia przez ludzi Stezenie ortofosforanow\nZakres:\nZakres (0,040 – 0,60) mg/l P-PO43-\nZakres (0,120 – 1,80) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdzial 4","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Orthophosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 rozdział 4","parameters_zh":[{"name":"范围","range":"(0,040 – 0,60) mg/l P-PO43-"},{"name":"范围","range":"(0,120 – 1,80) mg/l PO43-"}],"search_zh":"水、生活饮用水 正磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 rozdział 4","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9c2f1c10c8ce825f8dc","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (5 – 70) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8051","norm_bases":["PB-07 wydanie 3 z dnia 05.05.2021 r.","na podstawie testu Hach-Lange nr 8051"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie siarczanów\nZakres (5 – 70) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8051 Woda, woda do spozycia przez ludzi Stezenie siarczanow\nZakres (5 – 70) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8051","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sulfate concentration Spectrophotometric method Range PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8051","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 分光光度法 范围 PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange nr 8051","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8dd","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,06 – 12,8) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 10,0) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,06 – 12,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,05 – 10,0) mg/l\nStężenie jonu amonowego\nZakres (0,06 – 12,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002 z wyłączeniem p. 10","norm_bases":["PN-ISO 7150-1:2002 z wyłączeniem p. 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres:\nZakres (0,05 – 10,0) mg/l\nStężenie jonu amonowego\nZakres (0,06 – 12,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 z wyłączeniem p. 10 Woda, woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres:\nZakres (0,05 – 10,0) mg/l\nStezenie jonu amonowego\nZakres (0,06 – 12,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 z wylaczeniem p. 10","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration Range PN-ISO 7150-1:2002 z wyłączeniem p. 10","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,06 – 12,8) mg/l"}],"search_zh":"水、生活饮用水 氨氮浓度 分光光度法 范围 铵离子浓度 范围 PN-ISO 7150-1:2002 z wyłączeniem p. 10","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8de","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,005 – 1,0) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,016 − 3,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 1,0) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,016 − 3,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 1,0) mg/l\nStężenie azotynów\nZakres (0,016 − 3,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 1,0) mg/l\nStężenie azotynów\nZakres (0,016 − 3,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotu azotynowego\nZakres:\nZakres (0,005 – 1,0) mg/l\nStezenie azotynow\nZakres (0,016 − 3,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 1,0) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,016 − 3,5) mg/l"}],"search_zh":"水、生活饮用水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8df","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 − 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 − 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 − 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C","norm_bases":["PN-EN ISO 7887:2012 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 − 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C Woda, woda do spozycia przez ludzi Barwa\nZakres (5 − 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8e0","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Załącznik A","norm_bases":["PN-C-04554-4:1999 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Załącznik A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zalacznik A","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 Załącznik A","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 Załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9c2f1c10c8ce825f8e1","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,10 − 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 − 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,10 − 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-05 wydanie 2 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8029","norm_bases":["PB-05 wydanie 2 z dnia 05.05.2021 r.","na podstawie testu Hach-Lange 8029"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,10 − 2,00) mg/l\nMetoda spektrofotometryczna PB-05 wydanie 2 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8029 Woda, woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,10 − 2,00) mg/l\nMetoda spektrofotometryczna PB-05 wydanie 2 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8029","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Fluoride concentration Spectrophotometric method Range PB-05 wydanie 2 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8029","parameters_zh":[{"name":"范围","range":"(0,10 − 2,00) mg/l"}],"search_zh":"水、生活饮用水 氟化物浓度 分光光度法 范围 PB-05 wydanie 2 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8029","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a5dc9c2f1c10c8ce825f8e2","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,50 − 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 − 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 − 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 − 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 − 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 − 10) mg/l O2"}],"search_zh":"水（含游泳池水）、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8e3","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 50) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,18 – 221) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 50) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,18 – 221) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,04 – 50) mg/l\nStężenie azotanów\nZakres (0,18 – 221) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie azotu azotanowego\nZakres:\nZakres (0,04 – 50) mg/l\nStężenie azotanów\nZakres (0,18 – 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie azotu azotanowego\nZakres:\nZakres (0,04 – 50) mg/l\nStezenie azotanow\nZakres (0,18 – 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Nitrate nitrogen concentration Spectrophotometric method Range Nitrate concentration Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 50) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,18 – 221) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 硝态氮浓度 分光光度法 范围 硝酸盐浓度 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8e4","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(0,020 − 5,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 − 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (0,020 − 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,020 − 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,020 − 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 − 5,00) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8e5","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,06 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,06 – 2,00) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,06 – 2,00) mg/l\nMetoda kolorymetryczna","reference":"PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","norm_bases":["PB-11 wydanie 3 z dnia 18.02.2025 r.","na podstawie testu Hach-Lange nr 8021 i nr 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,06 – 2,00) mg/l\nMetoda kolorymetryczna PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,06 – 2,00) mg/l\nMetoda kolorymetryczna PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Free chlorine concentration Colorimetric method Range PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 2,00) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 游离氯浓度 比色法 范围 PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","technique_zh":"比色法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8e6","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie chloru całkowitego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,06 – 2,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,06 – 2,00) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"technique_en":"Colorimetric method","computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego\nZakres (0,06 – 2,00) mg/l\nMetoda kolorymetryczna","reference":"PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","norm_bases":["PB-11 wydanie 3 z dnia 18.02.2025 r.","na podstawie testu Hach-Lange nr 8021 i nr 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie chloru całkowitego\nZakres (0,06 – 2,00) mg/l\nMetoda kolorymetryczna PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie chloru calkowitego\nZakres (0,06 – 2,00) mg/l\nMetoda kolorymetryczna PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Total chlorine concentration Colorimetric method Range PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","parameters_zh":[{"name":"范围","range":"(0,06 – 2,00) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 总氯浓度 比色法 范围 PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","technique_zh":"比色法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"总氯浓度"},{"_id":"6a5dc9c2f1c10c8ce825f8e7","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","norm_bases":["PB-11 wydanie 3 z dnia 18.02.2025 r.","na podstawie testu Hach-Lange nr 8021 i nr 8167"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie chloru związanego (z obliczeń) PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie chloru zwiazanego (z obliczen) PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Combined chlorine concentration (calculated) PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","methodology_zh":"化合氯浓度（计算值）","search_zh":"水（含游泳池水）、生活饮用水 化合氯浓度（计算值） PB-11 wydanie 3 z dnia 18.02.2025 r. | na podstawie testu Hach-Lange nr 8021 i nr 8167","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8e8","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 − 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi pH\nZakres 3,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi pH\nZakres 3,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 − 10,0"}],"search_zh":"水（含游泳池水）、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8e9","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 20) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016","norm_bases":["PN-EN ISO 7027-1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 20) NTU"}],"search_zh":"水（含游泳池水）、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9c2f1c10c8ce825f8ea","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","methodology_en":"Chemical oxygen demand – COD-Cr","parameters":[{"name":"Zakres","range":"(15,0 − 15000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(15,0 − 15000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (15,0 − 15000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (15,0 − 15000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (15,0 − 15000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(15,0 − 15000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a5dc9c2f1c10c8ce825f8eb","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,050 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK348, LCK349","norm_bases":["PB-03 wydanie 4 z dnia 05.05.2021 r.","na podstawie testu Hach-Lange LCK348, LCK349"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna PB-03 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK348, LCK349 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna PB-03 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK348, LCK349","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PB-03 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK348, LCK349","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 50) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PB-03 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK348, LCK349","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c2f1c10c8ce825f8ec","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 400) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,00 – 400) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK238, LCK138","norm_bases":["PB-04 wydanie 4 z dnia 05.05.2021 r.","na podstawie testu Hach-Lange LCK238, LCK138"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (1,00 – 400) mg/l\nMetoda spektrofotometryczna PB-04 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK238, LCK138 Woda, scieki Stezenie azotu ogolnego\nZakres (1,00 – 400) mg/l\nMetoda spektrofotometryczna PB-04 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK238, LCK138","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration Spectrophotometric method Range PB-04 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK238, LCK138","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 400) mg/l"}],"search_zh":"水、废水 总氮浓度 分光光度法 范围 PB-04 wydanie 4 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange LCK238, LCK138","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c2f1c10c8ce825f8ed","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem 7.2.1., 7.2.2. | PB-13 wydanie 2 z dnia 05.05.2021 r.","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem 7.2.1., 7.2.2.","PB-13 wydanie 2 z dnia 05.05.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem 7.2.1., 7.2.2. | PB-13 wydanie 2 z dnia 05.05.2021 r. Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem 7.2.1., 7.2.2. | PB-13 wydanie 2 z dnia 05.05.2021 r.","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN 1899-2:2002 z wyłączeniem 7.2.1., 7.2.2. | PB-13 wydanie 2 z dnia 05.05.2021 r.","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 范围 PN-EN 1899-2:2002 z wyłączeniem 7.2.1., 7.2.2. | PB-13 wydanie 2 z dnia 05.05.2021 r.","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c2f1c10c8ce825f8ee","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Woda, ścieki,","test_object_en":"Water, wastewater,","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki, Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater, Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9c2f1c10c8ce825f8ef","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Wody roztopowe, wody opadowe","test_object_en":"Snowmelt water, rainwater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 100) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody roztopowe, wody opadowe Zawiesiny ogólne\nZakres (2,0 – 100) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody roztopowe, wody opadowe Zawiesiny ogolne\nZakres (2,0 – 100) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Snowmelt water, rainwater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9c2f1c10c8ce825f8f0","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki, Wody roztopowe, wody opadowe","test_object_en":"Wastewater, Snowmelt water, rainwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody roztopowe, wody opadowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki, Wody roztopowe, wody opadowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Snowmelt water, rainwater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法"},{"_id":"6a5dc9c2f1c10c8ce825f8f1","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12 | PB-13 wydanie 2 z dnia 05.05.2021 r.","norm_bases":["PN-EN ISO 5815-1:2019-12","PB-13 wydanie 2 z dnia 05.05.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 | PB-13 wydanie 2 z dnia 05.05.2021 r. Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 | PB-13 wydanie 2 z dnia 05.05.2021 r.","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand – BOD5 Optical method Range PN-EN ISO 5815-1:2019-12 | PB-13 wydanie 2 z dnia 05.05.2021 r.","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12 | PB-13 wydanie 2 z dnia 05.05.2021 r.","technique_zh":"光学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c2f1c10c8ce825f8f2","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 40) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,06 – 51) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 40) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,06 – 51) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,05 – 40) mg/l\nStężenie jonu amonowego\nZakres (0,06 – 51) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002 z wyłączeniem p. 10","norm_bases":["PN-ISO 7150-1:2002 z wyłączeniem p. 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,05 – 40) mg/l\nStężenie jonu amonowego\nZakres (0,06 – 51) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 z wyłączeniem p. 10 Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,05 – 40) mg/l\nStezenie jonu amonowego\nZakres (0,06 – 51) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 z wylaczeniem p. 10","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration Range PN-ISO 7150-1:2002 z wyłączeniem p. 10","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 40) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,06 – 51) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 铵离子浓度 范围 PN-ISO 7150-1:2002 z wyłączeniem p. 10","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f8f3","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,40 – 10,0) mg/l P-PO43-"},{"name":"Zakres","range":"(1,20 – 30,0) mg/l PO43-"}],"parameters_en":[{"name":"Range","range":"(0,40 – 10,0) mg/l P-PO43-"},{"name":"Range","range":"(1,20 – 30,0) mg/l PO43-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres:\nZakres (0,40 – 10,0) mg/l P-PO43-\nZakres (1,20 – 30,0) mg/l PO43-\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 rozdział 4","norm_bases":["PN-EN ISO 6878:2006 rozdział 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie ortofosforanów\nZakres:\nZakres (0,40 – 10,0) mg/l P-PO43-\nZakres (1,20 – 30,0) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdział 4 Scieki Stezenie ortofosforanow\nZakres:\nZakres (0,40 – 10,0) mg/l P-PO43-\nZakres (1,20 – 30,0) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdzial 4","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Orthophosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 rozdział 4","parameters_zh":[{"name":"范围","range":"(0,40 – 10,0) mg/l P-PO43-"},{"name":"范围","range":"(1,20 – 30,0) mg/l PO43-"}],"search_zh":"污水 正磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 rozdział 4","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9c2f1c10c8ce825f8f4","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,005 – 1,0) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,016 − 3,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 1,0) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,016 − 3,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 1,0) mg/l\nStężenie azotynów\nZakres (0,016 − 3,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,005 – 1,0) mg/l\nStężenie azotynów\nZakres (0,016 − 3,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,005 – 1,0) mg/l\nStezenie azotynow\nZakres (0,016 − 3,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 1,0) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,016 − 3,5) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f8f5","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 50) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,18 – 221) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 50) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,18 – 221) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,04 – 50) mg/l\nStężenie azotanów\nZakres (0,18 – 221) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,04 – 50) mg/l\nStężenie azotanów\nZakres (0,18 – 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,04 – 50) mg/l\nStezenie azotanow\nZakres (0,18 – 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Nitrate concentration Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 50) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,18 – 221) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 硝酸盐浓度 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f8f6","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(5 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8051","norm_bases":["PB-07 wydanie 3 z dnia 05.05.2021 r.","na podstawie testu Hach-Lange 8051"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8051 Scieki Stezenie siarczanow\nZakres (5 – 250) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8051","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sulfate concentration Spectrophotometric method Range PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8051","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 – 250) mg/l"}],"search_zh":"污水 硫酸盐浓度 分光光度法 范围 PB-07 wydanie 3 z dnia 05.05.2021 r. | na podstawie testu Hach-Lange 8051","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f8f7","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 − 10,0"}],"parameters_en":[{"name":"Range","range":"3,0 − 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 − 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH\nZakres 3,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 3,0 − 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 − 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f8f8","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 − 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 − 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 − 2000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (5 − 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 − 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 − 2000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9c2f1c10c8ce825f8f9","lab_id":"69ad52a3de79e566650fb496","country":"PL","accr_number":"AB 911","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(0,020 – 5,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (0,020 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie żelaza\nZakres (0,020 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Scieki Stezenie zelaza\nZakres (0,020 – 5,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 5,00) mg/l"}],"search_zh":"污水 铁浓度 分光光度法 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"污水"}],"has_pdf":true}