{"lab":{"_id":"69ad52a3de79e566650fb494","accr_number":"AB 910","country":"PL","accr_body":"PCA","address":"LABORATORIUM INŻYNIERII MATERIAŁOWEJ I ŚRODOWISKA, ul. Pszczyńska 37, 44-101 Gliwice","categories":["materials","food","petro","automotive","electronics"],"city":"Gliwice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":81,"name":"INSTYTUT TECHNIKI GÓRNICZEJ KOMAG","parse_status":"parsed","parse_version":3,"pdf_files":["AB_910.pdf"],"scope_summary":"","search_text":"instytut techniki górniczej komag laboratorium inżynierii materiałowej i środowiska, ul. pszczyńska 37, 44-101 gliwice materials other metrology food automotive pharma environment water electronics petro","status":"active","updated_at":"2026-03-08T14:51:48.332Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:31:23.937Z","location":{"type":"Point","coordinates":[18.6714,50.2945]},"email_confidence":"high","email_mx":true,"email_source":"https://komag.eu","fields_of_testing":[{"codes":"A/17; A/25","pl":"Badania akustyczne i drgań: wyroby inne; zabawki","en":"Acoustic and vibration tests: other products, toys"},{"codes":"C/4; C/5; C/6; C/8; C/11; C/12; C/13; C/14; C/17; C/18; C/19; C/20; C/21; C/23; C/24; C/25; C/26, C/27; C/31; C/32; C/42; C/45; C/46; C/49; C/50; C/51; C/53; C/54","pl":"Badania chemiczne: wyroby chemiczne; wyroby, materiały, obiekty budowlane; wyroby i wyposażenie elektryczne; wyroby i materiały konstrukcyjne; meble; szkło i ceramika; maszyny i urządzenia; wyposażenie medyczne; wyroby inne; papier, tektura; środki ochrony osobistej; wyroby farmaceutyczne; wyroby z tworzyw sztucznych i gumy; tekstylia i skóra; wyroby tytoniowe; zabawki; pojazdy, drewno; gleby, grunty, skały, osady, kosmetyki, farby i lakiery, materiały smarne, materiały opakowaniowe, sprzęt sportowy i rekreacyjny, place zabaw i ich wyposażenie, wyroby i wyposażenie telekomunikacyjne, wyroby i wyposażenie elektroniczne","en":"Chemical tests: chemical products, building products, materials and items, electrical products and equipment, construction products and materials, furniture, glass and ceramics, machinery and devices, medical equipment, other products, paper, cardboard, personal protection equipment, pharmaceutical products, plastic and rubber products, textiles and leather, tobacco products, toys, vehicles, wood, soil, ground, rocks, sediments, cosmetics, paints and varnishes, lubricants, packaging materials, sports and leisure equipment, playgrounds and equipment, telecommunication products and equipment, electronic products and equipment,"}],"issue":{"no":"26","date":"06.07.2026"},"parse_date":"2026-08-18T01:31:23.937Z","parse_source":"agent-claude-code","map_coord":[50.288147,18.672671],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM INŻYNIERII MATERIAŁOWEJ I ŚRODOWISKA","address":"ul. Pszczyńska 37","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/a409a7c4be81e1923133a66b1b4c1ee1/AB%20910.pdf","has_en":true,"category_counts":{"materials":56,"other":14,"food":13,"petro":10,"automotive":7,"electronics":6,"water":4,"environment":3,"pharma":2},"category_scores":{"materials":27.27,"other":1.7,"food":1.47,"petro":0.87,"automotive":0.43,"electronics":0.31,"water":0.14,"environment":0.08,"pharma":0.03},"has_zh":true},"methods":[{"_id":"6a83b5ecaf14b9c0e7b20e48","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"Wyroby z materiałów metalowych, wyroby z tworzyw sztucznych","methodology":"Chropowatość","parameters":[{"name":"Ra","range":"(0,01 − 75,0) μm"},{"name":"Rz","range":"(0,02 − 300) μm"}],"technique":"Metoda profilowa","techniques":["Metoda profilowa"],"computed":[],"activity":"Chropowatość\nZakres:\nRa (0,01 − 75,0) μm\nRz (0,02 − 300) μm\nMetoda profilowa","reference":"PN-EN ISO 21920-3:2022-06 *","norm_bases":["PN-EN ISO 21920-3:2022-06 *"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nBadania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Wyroby z materiałów metalowych, wyroby z tworzyw sztucznych Chropowatość\nZakres:\nRa (0,01 − 75,0) μm\nRz (0,02 − 300) μm\nMetoda profilowa PN-EN ISO 21920-3:2022-06 * Wyroby z materialow metalowych, wyroby z tworzyw sztucznych Chropowatosc\nZakres:\nRa (0,01 − 75,0) μm\nRz (0,02 − 300) μm\nMetoda profilowa PN-EN ISO 21920-3:2022-06 *","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Roughness","parameters_en":[{"name":"Ra","range":"(0,01 − 75,0) μm"},{"name":"Rz","range":"(0,02 − 300) μm"}],"regulatory_area_en":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Products made of metallic materials, plastic products Roughness Profile method + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Ra Rz PN-EN ISO 21920-3:2022-06 *","technique_en":"Profile method","test_object_en":"Products made of metallic materials, plastic products","regulatory_area_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出 PN-EN ISO 21920-3:2022-06 *"},{"_id":"6a83b5ecaf14b9c0e7b20e49","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"Wyroby z materiałów metalowych","methodology":"Grubość powłoki ochronnej","parameters":[{"name":"Zakres","range":"(0 − 960) μm"}],"technique":"Metoda magnetyczna","techniques":["Metoda magnetyczna"],"computed":[],"activity":"Grubość powłoki ochronnej\nZakres (0 − 960) μm\nMetoda magnetyczna","reference":"PN-EN ISO 2178:2016-06 *","norm_bases":["PN-EN ISO 2178:2016-06 *"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nBadania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Wyroby z materiałów metalowych Grubość powłoki ochronnej\nZakres (0 − 960) μm\nMetoda magnetyczna PN-EN ISO 2178:2016-06 * Wyroby z materialow metalowych Grubosc powloki ochronnej\nZakres (0 − 960) μm\nMetoda magnetyczna PN-EN ISO 2178:2016-06 *","categories":["materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thickness of the protective coating","parameters_en":[{"name":"Range","range":"(0 − 960) μm"}],"regulatory_area_en":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Products made of metallic materials Thickness of the protective coating Magnetic method + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Range PN-EN ISO 2178:2016-06 *","technique_en":"Magnetic method","test_object_en":"Products made of metallic materials","parameters_zh":[{"name":"范围","range":"(0 − 960) μm"}],"search_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出 范围 PN-EN ISO 2178:2016-06 *","regulatory_area_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出"},{"_id":"6a83b5ecaf14b9c0e7b20e4a","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"Wyroby z materiałów metalowych","methodology":"Grubość powłoki ochronnej","parameters":[{"name":"Zakres","range":"(0 − 960) μm"}],"technique":"Metoda prądów wirowych","techniques":["Metoda prądów wirowych"],"computed":[],"activity":"Grubość powłoki ochronnej\nZakres (0 − 960) μm\nMetoda prądów wirowych","reference":"PN-EN ISO 2360:2017-10 *","norm_bases":["PN-EN ISO 2360:2017-10 *"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nBadania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Wyroby z materiałów metalowych Grubość powłoki ochronnej\nZakres (0 − 960) μm\nMetoda prądów wirowych PN-EN ISO 2360:2017-10 * Wyroby z materialow metalowych Grubosc powloki ochronnej\nZakres (0 − 960) μm\nMetoda pradow wirowych PN-EN ISO 2360:2017-10 *","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thickness of the protective coating","parameters_en":[{"name":"Range","range":"(0 − 960) μm"}],"regulatory_area_en":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Products made of metallic materials Thickness of the protective coating Eddy current method + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Range PN-EN ISO 2360:2017-10 *","technique_en":"Eddy current method","test_object_en":"Products made of metallic materials","parameters_zh":[{"name":"范围","range":"(0 − 960) μm"}],"search_zh":"涡流法 + Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出 范围 PN-EN ISO 2360:2017-10 *","regulatory_area_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出","technique_zh":"涡流法"},{"_id":"6a83b5ecaf14b9c0e7b20e4b","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"Wyroby z materiałów metalowych","methodology":"Przyczepność do podłoża","parameters":[],"technique":"Metoda siatki nacięć","techniques":["Metoda siatki nacięć"],"computed":[],"activity":"Przyczepność do podłoża\nMetoda siatki nacięć","reference":"PN-EN ISO 2409:2021-03 *","norm_bases":["PN-EN ISO 2409:2021-03 *"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nBadania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Wyroby z materiałów metalowych Przyczepność do podłoża\nMetoda siatki nacięć PN-EN ISO 2409:2021-03 * Wyroby z materialow metalowych Przyczepnosc do podloza\nMetoda siatki naciec PN-EN ISO 2409:2021-03 *","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Adhesion to the substrate","regulatory_area_en":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Products made of metallic materials Adhesion to the substrate Cross-cut method + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol PN-EN ISO 2409:2021-03 *","technique_en":"Cross-cut method","test_object_en":"Products made of metallic materials","regulatory_area_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"与基层的粘结强度 + Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出 PN-EN ISO 2409:2021-03 *","methodology_zh":"与基层的粘结强度"},{"_id":"6a83b5ecaf14b9c0e7b20e4c","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"Wyroby metalowe, wyroby z tworzyw sztucznych i drewna, papieru, złącza spawane","methodology":"Wymiary","parameters":[{"name":"Pomiar bezpośredni"},{"name":"długość","range":"(0,01 – 5000) mm"},{"name":"odchyłka prostoliniowości i płaskości, owalność","range":"(0,00 – 10,50) mm,"},{"name":"ubytek grubości, ubytek na średnicy, ubytek korozyjny spoiny - metoda obliczeniowa"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres:\nPomiar bezpośredni\ndługość (0,01 – 5000) mm\nodchyłka prostoliniowości i płaskości, owalność (0,00 – 10,50) mm,\nubytek grubości, ubytek na średnicy, ubytek korozyjny spoiny - metoda obliczeniowa","reference":"PB-DLS/08 wyd.17 z dn. 03-01-2020 *","norm_bases":["PB-DLS/08 wyd.17 z dn. 03-01-2020 *"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nBadania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Wyroby metalowe, wyroby z tworzyw sztucznych i drewna, papieru, złącza spawane Wymiary\nZakres:\nPomiar bezpośredni\ndługość (0,01 – 5000) mm\nodchyłka prostoliniowości i płaskości, owalność (0,00 – 10,50) mm,\nubytek grubości, ubytek na średnicy, ubytek korozyjny spoiny - metoda obliczeniowa PB-DLS/08 wyd.17 z dn. 03-01-2020 * Wyroby metalowe, wyroby z tworzyw sztucznych i drewna, papieru, zlacza spawane Wymiary\nZakres:\nPomiar bezposredni\ndlugosc (0,01 – 5000) mm\nodchylka prostoliniowosci i plaskosci, owalnosc (0,00 – 10,50) mm,\nubytek grubosci, ubytek na srednicy, ubytek korozyjny spoiny - metoda obliczeniowa PB-DLS/08 wyd.17 z dn. 03-01-2020 *","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dimensions","parameters_en":[{"name":"Direct measurement"},{"name":"length","range":"(0,01 – 5000) mm"},{"name":"deviation from straightness and flatness, ovality","range":"(0,00 – 10,50) mm,"},{"name":"thickness loss, diameter loss, corrosion loss of the weld - calculation method"}],"regulatory_area_en":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metal products, products made of plastics and wood, paper, welded joints Dimensions + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Direct measurement length deviation from straightness and flatness, ovality thickness loss, diameter loss, corrosion loss of the weld - calculation method PB-DLS/08 wyd.17 z dn. 03-01-2020 *","test_object_en":"Metal products, products made of plastics and wood, paper, welded joints","methodology_zh":"尺寸","regulatory_area_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出","search_zh":"尺寸 + Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出 直接测量 长度 PB-DLS/08 wyd.17 z dn. 03-01-2020 *","parameters_zh":[{"name":"直接测量"},{"name":"长度","range":"(0,01 – 5000) mm"},{"name":"odchyłka prostoliniowości i płaskości, owalność","range":"(0,00 – 10,50) mm,"},{"name":"ubytek grubości, ubytek na średnicy, ubytek korozyjny spoiny - metoda obliczeniowa"}]},{"_id":"6a83b5ecaf14b9c0e7b20e4d","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"Wyroby metalowe, wyroby z tworzyw sztucznych i gumy, papieru, wyroby drewniane","methodology":"Masa Pomiar bezpośredni","parameters":[{"name":"Zakres","range":"(1 – 100 000) g"},{"name":"ubytek i przyrost masy - metoda obliczeniowa"}],"technique":null,"techniques":[],"computed":[],"activity":"Masa Pomiar bezpośredni\nZakres:\nZakres (1 – 100 000) g\nubytek i przyrost masy - metoda obliczeniowa","reference":"PB-DLS/08 wyd.17 z dn. 03-01-2020 *","norm_bases":["PB-DLS/08 wyd.17 z dn. 03-01-2020 *"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *","flexible":false,"search_text":"Wyroby metalowe, wyroby z tworzyw sztucznych i gumy, papieru, wyroby drewniane Masa Pomiar bezpośredni\nZakres:\nZakres (1 – 100 000) g\nubytek i przyrost masy - metoda obliczeniowa PB-DLS/08 wyd.17 z dn. 03-01-2020 * Wyroby metalowe, wyroby z tworzyw sztucznych i gumy, papieru, wyroby drewniane Masa Pomiar bezposredni\nZakres:\nZakres (1 – 100 000) g\nubytek i przyrost masy - metoda obliczeniowa PB-DLS/08 wyd.17 z dn. 03-01-2020 *","categories":["materials"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mass Direct measurement","parameters_en":[{"name":"Range","range":"(1 – 100 000) g"},{"name":"mass loss and mass gain - calculation method"}],"regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol","search_en":"Metal products, products made of plastics and rubber, paper, wooden products Mass Direct measurement Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol Range mass loss and mass gain - calculation method PB-DLS/08 wyd.17 z dn. 03-01-2020 *","test_object_en":"Metal products, products made of plastics and rubber, paper, wooden products","parameters_zh":[{"name":"范围","range":"(1 – 100 000) g"},{"name":"ubytek i przyrost masy - metoda obliczeniowa"}],"search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出 范围 PB-DLS/08 wyd.17 z dn. 03-01-2020 *","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出"},{"_id":"6a83b5ecaf14b9c0e7b20e4e","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja specyficzna bisfenolu A do płynów modelowych: 3% kwas octowy 10% etanol 20% etanol 50% etanol","parameters":[{"name":"Zakres","range":"(0,001 – 0,1) mg/dm3"}],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Migracja specyficzna bisfenolu A do płynów modelowych: 3% kwas octowy 10% etanol 20% etanol 50% etanol\nZakres (0,001 – 0,1) mg/dm3\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"PN-EN 13130-1:2006 | PB-DLS/80 wyd. 1 z dn. 16.06.2025 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością (Dz. U. L 12 z 15.01.2011, str. 1-89 z późn. zm.) Specyfikacja Techniczna CEN/TS 13130-13:2025","norm_bases":["PN-EN 13130-1:2006","PB-DLS/80 wyd. 1 z dn. 16.06.2025","Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością (Dz. U. L 12 z 15.01.2011, str. 1-89 z późn. zm.) Specyfikacja Techniczna CEN/TS 13130-13:2025"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja specyficzna bisfenolu A do płynów modelowych: 3% kwas octowy 10% etanol 20% etanol 50% etanol\nZakres (0,001 – 0,1) mg/dm3\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) PN-EN 13130-1:2006 | PB-DLS/80 wyd. 1 z dn. 16.06.2025 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością (Dz. U. L 12 z 15.01.2011, str. 1-89 z późn. zm.) Specyfikacja Techniczna CEN/TS 13130-13:2025 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja specyficzna bisfenolu A do plynow modelowych: 3% kwas octowy 10% etanol 20% etanol 50% etanol\nZakres (0,001 – 0,1) mg/dm3\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) PN-EN 13130-1:2006 | PB-DLS/80 wyd. 1 z dn. 16.06.2025 | Rozporzadzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materialow i wyrobow z tworzyw sztucznych przeznaczonych do kontaktu z zywnoscia (Dz. U. L 12 z 15.01.2011, str. 1-89 z pozn. zm.) Specyfikacja Techniczna CEN/TS 13130-13:2025","categories":["materials","food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,001 – 0,1) mg/dm3"}],"search_en":"Plastic materials and articles intended to come into contact with food Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) Range PN-EN 13130-1:2006 | PB-DLS/80 wyd. 1 z dn. 16.06.2025 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością (Dz. U. L 12 z 15.01.2011, str. 1-89 z późn. zm.) Specyfikacja Techniczna CEN/TS 13130-13:2025","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"范围","range":"(0,001 – 0,1) mg/dm3"}],"search_zh":"拟与食品接触的塑料材料及制品 液相色谱-串联质谱法（LC-MS-MS） 范围 PN-EN 13130-1:2006 | PB-DLS/80 wyd. 1 z dn. 16.06.2025 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością (Dz. U. L 12 z 15.01.2011, str. 1-89 z późn. zm.) Specyfikacja Techniczna CEN/TS 13130-13:2025","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）","test_object_zh":"拟与食品接触的塑料材料及制品"},{"_id":"6a83b5ecaf14b9c0e7b20e4f","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością, sprzęt do picia","methodology":"Migracja specyficzna pierwszorzędowych amin aromatycznych do płynów modelowych","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Migracja specyficzna pierwszorzędowych amin aromatycznych do płynów modelowych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN 13130-1 | PN-EN 14350 | PB-DLS/44 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie Komisji (UE) nr 284/2011 z dnia 22 marca 2011 r. ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong","norm_bases":["PN-EN 13130-1","PN-EN 14350","PB-DLS/44","Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością","Rozporządzenie Komisji (UE) nr 284/2011 z dnia 22 marca 2011 r. ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością, sprzęt do picia Migracja specyficzna pierwszorzędowych amin aromatycznych do płynów modelowych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS); Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-EN 13130-1 | PN-EN 14350 | PB-DLS/44 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie Komisji (UE) nr 284/2011 z dnia 22 marca 2011 r. ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong E, Materialy i wyroby przeznaczone do kontaktu z zywnoscia, sprzet do picia Migracja specyficzna pierwszorzedowych amin aromatycznych do plynow modelowych\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS); Metoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-EN 13130-1 | PN-EN 14350 | PB-DLS/44 | Rozporzadzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materialow i wyrobow z tworzyw sztucznych przeznaczonych do kontaktu z zywnoscia | Rozporzadzenie Komisji (UE) nr 284/2011 z dnia 22 marca 2011 r. ustanawiajace specjalne warunki i szczegolowe procedury dotyczace przywozu przyborow kuchennych z tworzyw poliamidowych i melaminowych pochodzacych lub wyslanych z Chinskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong","categories":["materials","food"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specific migration of primary aromatic amines into food simulants","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Specific migration of primary aromatic amines into food simulants Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS); High-performance liquid chromatography with diode array detection (HPLC-DAD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 13130-1 | PN-EN 14350 | PB-DLS/44 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie Komisji (UE) nr 284/2011 z dnia 22 marca 2011 r. ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS); High-performance liquid chromatography with diode array detection (HPLC-DAD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 13130-1 | PN-EN 14350 | PB-DLS/44 | Rozporządzenie Komisji (UE) nr 10/2011 z dn.14.01.2011 r. w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie Komisji (UE) nr 284/2011 z dnia 22 marca 2011 r. ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong"},{"_id":"6a83b5ecaf14b9c0e7b20e50","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Tworzywa poliwęglanowe, Materiały i wyroby przeznaczone do kontaktu z żywnością, Powłoki, materiały powlekane","methodology":"Migracja specyficzna związków, BADGE, BFDGE oraz ich pochodnych do płynów modelowych","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Migracja specyficzna związków, BADGE, BFDGE oraz ich pochodnych do płynów modelowych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-DLS/69 | PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie (WE) nr 1895/2005 w sprawie ograniczenia wykorzystania niektórych pochodnych epoksydowych w materiałach i wyrobach przeznaczonych do kontaktu z żywnością","norm_bases":["PB-DLS/69","PN-EN 13130-1","Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością","Rozporządzenie (WE) nr 1895/2005 w sprawie ograniczenia wykorzystania niektórych pochodnych epoksydowych w materiałach i wyrobach przeznaczonych do kontaktu z żywnością"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Tworzywa poliwęglanowe, Materiały i wyroby przeznaczone do kontaktu z żywnością, Powłoki, materiały powlekane Migracja specyficzna związków, BADGE, BFDGE oraz ich pochodnych do płynów modelowych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) PB-DLS/69 | PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie (WE) nr 1895/2005 w sprawie ograniczenia wykorzystania niektórych pochodnych epoksydowych w materiałach i wyrobach przeznaczonych do kontaktu z żywnością E, Tworzywa poliweglanowe, Materialy i wyroby przeznaczone do kontaktu z zywnoscia, Powloki, materialy powlekane Migracja specyficzna zwiazkow, BADGE, BFDGE oraz ich pochodnych do plynow modelowych\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) PB-DLS/69 | PN-EN 13130-1 | Rozporzadzenie Komisji (UE) nr 10/2011 w sprawie materialow i wyrobow z tworzyw sztucznych przeznaczonych do kontaktu z zywnoscia | Rozporzadzenie (WE) nr 1895/2005 w sprawie ograniczenia wykorzystania niektorych pochodnych epoksydowych w materialach i wyrobach przeznaczonych do kontaktu z zywnoscia","categories":["materials","food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/69 | PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie (WE) nr 1895/2005 w sprawie ograniczenia wykorzystania niektórych pochodnych epoksydowych w materiałach i wyrobach przeznaczonych do kontaktu z żywnością","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"液相色谱-串联质谱法（LC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/69 | PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | Rozporządzenie (WE) nr 1895/2005 w sprawie ograniczenia wykorzystania niektórych pochodnych epoksydowych w materiałach i wyrobach przeznaczonych do kontaktu z żywnością","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e51","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Papier, tektura, Tworzywa sztuczne, Materiały opakowaniowe, Materiały przeznaczone do kontaktu z żywnością, Powłoki, Wyroby powlekane, Wyroby włókiennicze i tekstylne","methodology":"Zawartość związków per- i polifluoroalkilowych (PFAS i PFOA)","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Zawartość związków per- i polifluoroalkilowych (PFAS i PFOA)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-DLS/68 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady z dn. 18.12.2006 r. – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","norm_bases":["PB-DLS/68","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady z dn. 18.12.2006 r. – REACH","Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Papier, tektura, Tworzywa sztuczne, Materiały opakowaniowe, Materiały przeznaczone do kontaktu z żywnością, Powłoki, Wyroby powlekane, Wyroby włókiennicze i tekstylne Zawartość związków per- i polifluoroalkilowych (PFAS i PFOA)\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) PB-DLS/68 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady z dn. 18.12.2006 r. – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs E, Papier, tektura, Tworzywa sztuczne, Materialy opakowaniowe, Materialy przeznaczone do kontaktu z zywnoscia, Powloki, Wyroby powlekane, Wyroby wlokiennicze i tekstylne Zawartosc zwiazkow per- i polifluoroalkilowych (PFAS i PFOA)\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) PB-DLS/68 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady z dn. 18.12.2006 r. – REACH | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","categories":["materials","food"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of per- and polyfluoroalkyl substances (PFAS and PFOA)","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Content of per- and polyfluoroalkyl substances (PFAS and PFOA) Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/68 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady z dn. 18.12.2006 r. – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"液相色谱-串联质谱法（LC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/68 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady z dn. 18.12.2006 r. – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e52","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Papier, tektura, Tworzywa sztuczne, Materiały opakowaniowe, Materiały przeznaczone do kontaktu z żywnością, Powłoki, materiały powlekane","methodology":"Migracja specyficzna związków per- i polifluoroalkilowych (PFAS i PFOA) do płynów modelowych","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Migracja specyficzna związków per- i polifluoroalkilowych (PFAS i PFOA) do płynów modelowych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-DLS/68","norm_bases":["PB-DLS/68"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Papier, tektura, Tworzywa sztuczne, Materiały opakowaniowe, Materiały przeznaczone do kontaktu z żywnością, Powłoki, materiały powlekane Migracja specyficzna związków per- i polifluoroalkilowych (PFAS i PFOA) do płynów modelowych\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) PB-DLS/68 E, Papier, tektura, Tworzywa sztuczne, Materialy opakowaniowe, Materialy przeznaczone do kontaktu z zywnoscia, Powloki, materialy powlekane Migracja specyficzna zwiazkow per- i polifluoroalkilowych (PFAS i PFOA) do plynow modelowych\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) PB-DLS/68","categories":["materials","food"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/68","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"液相色谱-串联质谱法（LC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/68","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e53","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały które mogą mieć kontakt z dziećmi, Tworzywa sztuczne, gumy","methodology":"Badania bezpieczeństwa, Migracja bisfenolu A","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Migracja bisfenolu A\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-DLS/16 | PN-EN 71-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PB-DLS/16","PN-EN 71-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały które mogą mieć kontakt z dziećmi, Tworzywa sztuczne, gumy Badania bezpieczeństwa, Migracja bisfenolu A\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS-MS) PB-DLS/16 | PN-EN 71-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci, materialy ktore moga miec kontakt z dziecmi, Tworzywa sztuczne, gumy Badania bezpieczenstwa, Migracja bisfenolu A\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS-MS) PB-DLS/16 | PN-EN 71-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/16 | PN-EN 71-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"液相色谱-串联质谱法（LC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/16 | PN-EN 71-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e54","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Farby i lakiery","methodology":"Gęstość","parameters":[],"technique":"Metoda piknometryczna","techniques":["Metoda piknometryczna"],"computed":[],"activity":"Gęstość\nMetoda piknometryczna","reference":"PB-DLS/70 | PN-EN ISO 2811-1","norm_bases":["PB-DLS/70","PN-EN ISO 2811-1"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Farby i lakiery Gęstość\nMetoda piknometryczna PB-DLS/70 | PN-EN ISO 2811-1 E, Farby i lakiery Gestosc\nMetoda piknometryczna PB-DLS/70 | PN-EN ISO 2811-1","categories":["automotive"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Density","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Density Pycnometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/70 | PN-EN ISO 2811-1","technique_en":"Pycnometric method","methodology_zh":"密度","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"密度 比重瓶法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/70 | PN-EN ISO 2811-1","technique_zh":"比重瓶法"},{"_id":"6a83b5ecaf14b9c0e7b20e55","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Farby i lakiery, Substancje błonotwórcze do farb i lakierów, Dyspersje polimerów, Żywice kondensacyjne","methodology":"Zawartość substancji nielotnych","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji nielotnych\nMetoda wagowa","reference":"PB-DLS/70 | PN-EN ISO 3251","norm_bases":["PB-DLS/70","PN-EN ISO 3251"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Farby i lakiery, Substancje błonotwórcze do farb i lakierów, Dyspersje polimerów, Żywice kondensacyjne Zawartość substancji nielotnych\nMetoda wagowa PB-DLS/70 | PN-EN ISO 3251 E, Farby i lakiery, Substancje blonotworcze do farb i lakierow, Dyspersje polimerow, Zywice kondensacyjne Zawartosc substancji nielotnych\nMetoda wagowa PB-DLS/70 | PN-EN ISO 3251","categories":["materials","automotive"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Non-volatile matter content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Non-volatile matter content Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/70 | PN-EN ISO 3251","technique_en":"Gravimetric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"不挥发物含量 重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/70 | PN-EN ISO 3251","technique_zh":"重量法","methodology_zh":"不挥发物含量"},{"_id":"6a83b5ecaf14b9c0e7b20e56","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Farby i lakiery","methodology":"Badania bezpieczeństwa, Zawartość lotnych związków organicznych (VOC)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość lotnych związków organicznych (VOC)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN ISO 11890-2 Dyrektywa 2004/42/WE Parlamentu Europejskiego I Rady w sprawie ograniczeń emisji lotnych związków organicznych w wyniku stosowania rozpuszczalników organicznych w niektórych farbach i lakierach oraz produktach do odnawiania pojazdów, a także zmieniająca dyrektywę 1999/13/WE","norm_bases":["PN-EN ISO 11890-2 Dyrektywa 2004/42/WE Parlamentu Europejskiego I Rady w sprawie ograniczeń emisji lotnych związków organicznych w wyniku stosowania rozpuszczalników organicznych w niektórych farbach i lakierach oraz produktach do odnawiania pojazdów, a także zmieniająca dyrektywę 1999/13/WE"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania farb i lakierów wykonywane dla celów obszaru regulowanego *\n* Rozporządzenie Ministra Rozwoju z dnia 8 sierpnia 2016 r. w sprawie ograniczenia emisji lotnych związków organicznych zawartych w niektórych farbach i lakierach przeznaczonych do malowania budynków i ich elementów wykończeniowych, wyposażeniowych oraz związanych z budynkami i tymi elementami konstrukcji oraz w mieszaninach do odnawiania pojazdów, Dz.U. z 2016 r. poz. 1353\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Farby i lakiery Badania bezpieczeństwa, Zawartość lotnych związków organicznych (VOC)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN ISO 11890-2 Dyrektywa 2004/42/WE Parlamentu Europejskiego I Rady w sprawie ograniczeń emisji lotnych związków organicznych w wyniku stosowania rozpuszczalników organicznych w niektórych farbach i lakierach oraz produktach do odnawiania pojazdów, a także zmieniająca dyrektywę 1999/13/WE E, Farby i lakiery Badania bezpieczenstwa, Zawartosc lotnych zwiazkow organicznych (VOC)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN ISO 11890-2 Dyrektywa 2004/42/WE Parlamentu Europejskiego I Rady w sprawie ograniczen emisji lotnych zwiazkow organicznych w wyniku stosowania rozpuszczalnikow organicznych w niektorych farbach i lakierach oraz produktach do odnawiania pojazdow, a takze zmieniajaca dyrektywe 1999/13/WE","categories":["automotive","environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Volatile organic compound (VOC) content","regulatory_area_en":"Badania farb i lakierów wykonywane dla celów obszaru regulowanego *\n* Rozporządzenie Ministra Rozwoju z dnia 8 sierpnia 2016 r. w sprawie ograniczenia emisji lotnych związków organicznych zawartych w niektórych farbach i lakierach przeznaczonych do malowania budynków i ich elementów wykończeniowych, wyposażeniowych oraz związanych z budynkami i tymi elementami konstrukcji oraz w mieszaninach do odnawiania pojazdów, Dz.U. z 2016 r. poz. 1353\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Volatile organic compound (VOC) content Gas chromatography with mass spectrometry detection (GC-MS) Badania farb i lakierów wykonywane dla celów obszaru regulowanego *\n* Rozporządzenie Ministra Rozwoju z dnia 8 sierpnia 2016 r. w sprawie ograniczenia emisji lotnych związków organicznych zawartych w niektórych farbach i lakierach przeznaczonych do malowania budynków i ich elementów wykończeniowych, wyposażeniowych oraz związanych z budynkami i tymi elementami konstrukcji oraz w mieszaninach do odnawiania pojazdów, Dz.U. z 2016 r. poz. 1353\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 11890-2 Dyrektywa 2004/42/WE Parlamentu Europejskiego I Rady w sprawie ograniczeń emisji lotnych związków organicznych w wyniku stosowania rozpuszczalników organicznych w niektórych farbach i lakierach oraz produktach do odnawiania pojazdów, a także zmieniająca dyrektywę 1999/13/WE","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"Badania farb i lakierów wykonywane dla celów obszaru regulowanego *\n* Rozporządzenie Ministra Rozwoju z dnia 8 sierpnia 2016 r. w sprawie ograniczenia emisji lotnych związków organicznych zawartych w niektórych farbach i lakierach przeznaczonych do malowania budynków i ich elementów wykończeniowych, wyposażeniowych oraz związanych z budynkami i tymi elementami konstrukcji oraz w mieszaninach do odnawiania pojazdów, Dz.U. z 2016 r. poz. 1353\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） Badania farb i lakierów wykonywane dla celów obszaru regulowanego *\n* Rozporządzenie Ministra Rozwoju z dnia 8 sierpnia 2016 r. w sprawie ograniczenia emisji lotnych związków organicznych zawartych w niektórych farbach i lakierach przeznaczonych do malowania budynków i ich elementów wykończeniowych, wyposażeniowych oraz związanych z budynkami i tymi elementami konstrukcji oraz w mieszaninach do odnawiania pojazdów, Dz.U. z 2016 r. poz. 1353\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 11890-2 Dyrektywa 2004/42/WE Parlamentu Europejskiego I Rady w sprawie ograniczeń emisji lotnych związków organicznych w wyniku stosowania rozpuszczalników organicznych w niektórych farbach i lakierach oraz produktach do odnawiania pojazdów, a także zmieniająca dyrektywę 1999/13/WE","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e57","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Farby i lakiery, Impregnaty, Grunty, Bejce","methodology":"Badania bezpieczeństwa","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa","reference":"PB-DLS/66 | PN-EN ISO 11890-2","norm_bases":["PB-DLS/66","PN-EN ISO 11890-2"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Farby i lakiery, Impregnaty, Grunty, Bejce Badania bezpieczeństwa PB-DLS/66 | PN-EN ISO 11890-2 E, Farby i lakiery, Impregnaty, Grunty, Bejce Badania bezpieczenstwa PB-DLS/66 | PN-EN ISO 11890-2","categories":["automotive"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/66 | PN-EN ISO 11890-2","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/66 | PN-EN ISO 11890-2"},{"_id":"6a83b5ecaf14b9c0e7b20e58","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Farby i lakiery, Impregnaty, Grunty, Bejce","methodology":"Zawartość lotnych związków organicznych (VOC)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Zawartość lotnych związków organicznych (VOC)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DLS/66 | PN-EN ISO 11890-2","norm_bases":["PB-DLS/66","PN-EN ISO 11890-2"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Farby i lakiery, Impregnaty, Grunty, Bejce Zawartość lotnych związków organicznych (VOC)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DLS/66 | PN-EN ISO 11890-2 E, Farby i lakiery, Impregnaty, Grunty, Bejce Zawartosc lotnych zwiazkow organicznych (VOC)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DLS/66 | PN-EN ISO 11890-2","categories":["automotive"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile organic compound (VOC) content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Volatile organic compound (VOC) content Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/66 | PN-EN ISO 11890-2","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/66 | PN-EN ISO 11890-2","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e59","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Powłoki ochronne, wyroby metalowe, w tym złącza spawane","methodology":"Odporność korozyjna","parameters":[{"name":"Odporność korozyjna"}],"technique":"Metoda przyspieszona w atmosferze mgły solnej","techniques":["Metoda przyspieszona w atmosferze mgły solnej"],"computed":[],"activity":"Odporność korozyjna\nMetoda przyspieszona w atmosferze mgły solnej","reference":"PN-EN ISO 10289 | PN-EN ISO 4628-2 | PN-EN ISO 9227","norm_bases":["PN-EN ISO 10289","PN-EN ISO 4628-2","PN-EN ISO 9227"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Powłoki ochronne, wyroby metalowe, w tym złącza spawane Odporność korozyjna\nMetoda przyspieszona w atmosferze mgły solnej PN-EN ISO 10289 | PN-EN ISO 4628-2 | PN-EN ISO 9227 E, Powloki ochronne, wyroby metalowe, w tym zlacza spawane Odpornosc korozyjna\nMetoda przyspieszona w atmosferze mgly solnej PN-EN ISO 10289 | PN-EN ISO 4628-2 | PN-EN ISO 9227","categories":["materials"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Corrosion resistance","parameters_en":[{"name":"Corrosion resistance"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Corrosion resistance Accelerated method in a salt spray atmosphere E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Corrosion resistance PN-EN ISO 10289 | PN-EN ISO 4628-2 | PN-EN ISO 9227","technique_en":"Accelerated method in a salt spray atmosphere","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 10289 | PN-EN ISO 4628-2 | PN-EN ISO 9227"},{"_id":"6a83b5ecaf14b9c0e7b20e5a","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby płynne, wyroby na bazie wody, Materiały na zabawki i zabawki na bazie wody, Farby, kleje, zawiesiny, pigmenty","methodology":"Badania bezpieczeństwa, Zawartość formaldehydu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość formaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PB-DLS/61 Document European Directorate for the Quality of Medicines & HealthCare (EDQM), Determination of free formaldehyde in cosmetic products Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PB-DLS/61 Document European Directorate for the Quality of Medicines & HealthCare (EDQM), Determination of free formaldehyde in cosmetic products Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby płynne, wyroby na bazie wody, Materiały na zabawki i zabawki na bazie wody, Farby, kleje, zawiesiny, pigmenty Badania bezpieczeństwa, Zawartość formaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PB-DLS/61 Document European Directorate for the Quality of Medicines & HealthCare (EDQM), Determination of free formaldehyde in cosmetic products Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Wyroby plynne, wyroby na bazie wody, Materialy na zabawki i zabawki na bazie wody, Farby, kleje, zawiesiny, pigmenty Badania bezpieczenstwa, Zawartosc formaldehydu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PB-DLS/61 Document European Directorate for the Quality of Medicines & HealthCare (EDQM), Determination of free formaldehyde in cosmetic products Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials","water","pharma"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Formaldehyde content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Formaldehyde content High-performance liquid chromatography with diode array detection (HPLC-DAD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/61 Document European Directorate for the Quality of Medicines & HealthCare (EDQM), Determination of free formaldehyde in cosmetic products Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/61 Document European Directorate for the Quality of Medicines & HealthCare (EDQM), Determination of free formaldehyde in cosmetic products Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a83b5ecaf14b9c0e7b20e5b","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, Materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Drewno, wyroby drewniane i drewnopochodne","methodology":"Badania bezpieczeństwa, Zawartość konserwantów drewna","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość konserwantów drewna\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PB-DLS/62 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PN-EN 71-9","PN-EN 71-10","PN-EN 71-11","PB-DLS/62 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, Materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Drewno, wyroby drewniane i drewnopochodne Badania bezpieczeństwa, Zawartość konserwantów drewna\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PB-DLS/62 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Zabawki, artykuly dla dzieci, Materialy na zabawki i artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Drewno, wyroby drewniane i drewnopochodne Badania bezpieczenstwa, Zawartosc konserwantow drewna\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PB-DLS/62 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["materials"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Wood preservative content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Wood preservative content Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PB-DLS/62 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PB-DLS/62 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e5c","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, zabawki i artykuły dla dzieci Sprzęt rekreacyjny i sportowy oraz surowce do ich produkcji, Tworzywa sztuczne, tekstylia","methodology":"Badania bezpieczeństwa, Zawartość formamidu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość formamidu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DLS/59 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PB-DLS/59 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, zabawki i artykuły dla dzieci Sprzęt rekreacyjny i sportowy oraz surowce do ich produkcji, Tworzywa sztuczne, tekstylia Badania bezpieczeństwa, Zawartość formamidu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DLS/59 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby konsumenckie, zabawki i artykuly dla dzieci Sprzet rekreacyjny i sportowy oraz surowce do ich produkcji, Tworzywa sztuczne, tekstylia Badania bezpieczenstwa, Zawartosc formamidu\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DLS/59 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["materials"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Formamide content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Formamide content Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/59 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/59 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e5d","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, zabawki i artykuły dla dzieci, ich elementy wykonane z elastomerów i gumy oraz surowce do ich produkcji","methodology":"Badania bezpieczeństwa, Zawartość N-nitrozoamin oraz substancji N-nitrozowych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość N-nitrozoamin oraz substancji N-nitrozowych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PN-EN 71-7 | PN-EN 71-12 | PN-EN 12868","norm_bases":["PN-EN 71-7","PN-EN 71-12","PN-EN 12868"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, zabawki i artykuły dla dzieci, ich elementy wykonane z elastomerów i gumy oraz surowce do ich produkcji Badania bezpieczeństwa, Zawartość N-nitrozoamin oraz substancji N-nitrozowych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PN-EN 71-7 | PN-EN 71-12 | PN-EN 12868 E, Wyroby konsumenckie, zabawki i artykuly dla dzieci, ich elementy wykonane z elastomerow i gumy oraz surowce do ich produkcji Badania bezpieczenstwa, Zawartosc N-nitrozoamin oraz substancji N-nitrozowych\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PN-EN 71-7 | PN-EN 71-12 | PN-EN 12868","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Content of N-nitrosamines and N-nitroso substances","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Content of N-nitrosamines and N-nitroso substances Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-7 | PN-EN 71-12 | PN-EN 12868","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-串联质谱法（GC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-7 | PN-EN 71-12 | PN-EN 12868","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e5e","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie i artykuły dla dzieci, ich elementy wykonane z elastomerów i gumy oraz surowce do ich produkcji","methodology":"Badania bezpieczeństwa, Zawartość N-nitrozoamin oraz związków ulegających, N-nitrozowaniu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość N-nitrozoamin oraz związków ulegających, N-nitrozowaniu\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PN-EN 12868 | PN-EN 1400 | PN-EN 14350 | PN-EN 71-12 Dyrektywa Komisji 93/11/EWG dot. uwalniania N-nitrozoamin i substancji zdolnych do tworzenia N-nitrozoamin ze smoczków do karmienia niemowląt i smoczków do uspokajania wykonanych z kauczuku naturalnego lub elastomerów syntetycznych","norm_bases":["PN-EN 12868","PN-EN 1400","PN-EN 14350","PN-EN 71-12 Dyrektywa Komisji 93/11/EWG dot. uwalniania N-nitrozoamin i substancji zdolnych do tworzenia N-nitrozoamin ze smoczków do karmienia niemowląt i smoczków do uspokajania wykonanych z kauczuku naturalnego lub elastomerów syntetycznych"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie i artykuły dla dzieci, ich elementy wykonane z elastomerów i gumy oraz surowce do ich produkcji Badania bezpieczeństwa, Zawartość N-nitrozoamin oraz związków ulegających, N-nitrozowaniu\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PN-EN 12868 | PN-EN 1400 | PN-EN 14350 | PN-EN 71-12 Dyrektywa Komisji 93/11/EWG dot. uwalniania N-nitrozoamin i substancji zdolnych do tworzenia N-nitrozoamin ze smoczków do karmienia niemowląt i smoczków do uspokajania wykonanych z kauczuku naturalnego lub elastomerów syntetycznych E, Wyroby konsumenckie i artykuly dla dzieci, ich elementy wykonane z elastomerow i gumy oraz surowce do ich produkcji Badania bezpieczenstwa, Zawartosc N-nitrozoamin oraz zwiazkow ulegajacych, N-nitrozowaniu\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PN-EN 12868 | PN-EN 1400 | PN-EN 14350 | PN-EN 71-12 Dyrektywa Komisji 93/11/EWG dot. uwalniania N-nitrozoamin i substancji zdolnych do tworzenia N-nitrozoamin ze smoczkow do karmienia niemowlat i smoczkow do uspokajania wykonanych z kauczuku naturalnego lub elastomerow syntetycznych","categories":["materials"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Content of N-nitrosamines and compounds subject to, N-nitrosation","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Content of N-nitrosamines and compounds subject to, N-nitrosation Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 12868 | PN-EN 1400 | PN-EN 14350 | PN-EN 71-12 Dyrektywa Komisji 93/11/EWG dot. uwalniania N-nitrozoamin i substancji zdolnych do tworzenia N-nitrozoamin ze smoczków do karmienia niemowląt i smoczków do uspokajania wykonanych z kauczuku naturalnego lub elastomerów syntetycznych","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-串联质谱法（GC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 12868 | PN-EN 1400 | PN-EN 14350 | PN-EN 71-12 Dyrektywa Komisji 93/11/EWG dot. uwalniania N-nitrozoamin i substancji zdolnych do tworzenia N-nitrozoamin ze smoczków do karmienia niemowląt i smoczków do uspokajania wykonanych z kauczuku naturalnego lub elastomerów syntetycznych","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e5f","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, polistyrenowe, oraz surowce do ich produkcji, Elementy polimerowe, tekstylne, polistyrenowe, artykułów dla dzieci i wyrobów konsumenckich, oraz surowce do ich produkcji, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość heksabromocyklododekanu – HBCD","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość heksabromocyklododekanu – HBCD\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DLS/53 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs Dyrektywa 2011/65/UE – RoHS","norm_bases":["PB-DLS/53","Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs Dyrektywa 2011/65/UE – RoHS"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, polistyrenowe, oraz surowce do ich produkcji, Elementy polimerowe, tekstylne, polistyrenowe, artykułów dla dzieci i wyrobów konsumenckich, oraz surowce do ich produkcji, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość heksabromocyklododekanu – HBCD\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DLS/53 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs Dyrektywa 2011/65/UE – RoHS E, Sprzet elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, polistyrenowe, oraz surowce do ich produkcji, Elementy polimerowe, tekstylne, polistyrenowe, artykulow dla dzieci i wyrobow konsumenckich, oraz surowce do ich produkcji, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc heksabromocyklododekanu – HBCD\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DLS/53 | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs Dyrektywa 2011/65/UE – RoHS","categories":["materials","petro","electronics"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Hexabromocyclododecane – HBCD content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Hexabromocyclododecane – HBCD content Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/53 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs Dyrektywa 2011/65/UE – RoHS","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/53 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs Dyrektywa 2011/65/UE – RoHS","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e60","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby z tworzyw sztucznych i gumy, nawierzchnie syntetyczne, sportowe, nawierzchnie placów zabaw, nawierzchnie syntetycznej murawy (wyciągi wodne), Gleby, grunty, skały, kruszywa, osady, wyroby konsumenckie oraz surowce do ich produkcji (wyciągi wodne)","methodology":"Badania bezpieczeństwa, Stężenie i zawartość pierwiastków","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS); Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)","Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Stężenie i zawartość pierwiastków\nMetoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS); Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 12457-4 | DIN 18035-6 | DIN 18035-7 | PN-ISO 11465 | PN-EN 12880","norm_bases":["PN-EN 12457-4","DIN 18035-6","DIN 18035-7","PN-ISO 11465","PN-EN 12880"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby z tworzyw sztucznych i gumy, nawierzchnie syntetyczne, sportowe, nawierzchnie placów zabaw, nawierzchnie syntetycznej murawy (wyciągi wodne), Gleby, grunty, skały, kruszywa, osady, wyroby konsumenckie oraz surowce do ich produkcji (wyciągi wodne) Badania bezpieczeństwa, Stężenie i zawartość pierwiastków\nMetoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS); Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 12457-4 | DIN 18035-6 | DIN 18035-7 | PN-ISO 11465 | PN-EN 12880 E, Wyroby z tworzyw sztucznych i gumy, nawierzchnie syntetyczne, sportowe, nawierzchnie placow zabaw, nawierzchnie syntetycznej murawy (wyciagi wodne), Gleby, grunty, skaly, kruszywa, osady, wyroby konsumenckie oraz surowce do ich produkcji (wyciagi wodne) Badania bezpieczenstwa, Stezenie i zawartosc pierwiastkow\nMetoda wysokosprawnej chromatografii cieczowej sprzezonej ze spektrometria mas z jonizacja w plazmie indukcyjnie sprzezonej (HPLC-ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rteci (CVAAS); Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 12457-4 | DIN 18035-6 | DIN 18035-7 | PN-ISO 11465 | PN-EN 12880","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Concentration and content of elements","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Concentration and content of elements High-performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS); Atomic absorption spectrometry with cold vapour mercury generation (CVAAS); Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 12457-4 | DIN 18035-6 | DIN 18035-7 | PN-ISO 11465 | PN-EN 12880","technique_en":"High-performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC-ICP-MS); Atomic absorption spectrometry with cold vapour mercury generation (CVAAS); Inductively coupled plasma mass spectrometry (ICP-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 12457-4 | DIN 18035-6 | DIN 18035-7 | PN-ISO 11465 | PN-EN 12880"},{"_id":"6a83b5ecaf14b9c0e7b20e61","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, Zabawki elektryczne, Sprzęt elektryczny i elektroniczny, Artykuły dla dzieci, Huśtawki dla niemowląt, Leżaczki niemowlęce","methodology":"Badania bezpieczeństwa, Właściwości mechaniczne, fizyczne, Właściwości elektryczne, Odporność na wysoką temperaturę i żar, Pomiar bezpośredni i pośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Właściwości mechaniczne, fizyczne, Właściwości elektryczne, Odporność na wysoką temperaturę i żar, Pomiar bezpośredni i pośredni","reference":"* | PN-EN 62115 | PN-EN IEC 62115 | PN-EN 60695-11-5 | PN-EN IEC 60695-2-11 | PN-EN 60695-10-2 | PN-EN IEC 60695-2-10 | PN-EN 62208 | PN-EN 16232 | PN-EN 12790-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/05 | PB-DLS/10","norm_bases":["*","PN-EN 62115","PN-EN IEC 62115","PN-EN 60695-11-5","PN-EN IEC 60695-2-11","PN-EN 60695-10-2","PN-EN IEC 60695-2-10","PN-EN 62208","PN-EN 16232","PN-EN 12790-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","PB-DLS/05","PB-DLS/10"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, Zabawki elektryczne, Sprzęt elektryczny i elektroniczny, Artykuły dla dzieci, Huśtawki dla niemowląt, Leżaczki niemowlęce Badania bezpieczeństwa, Właściwości mechaniczne, fizyczne, Właściwości elektryczne, Odporność na wysoką temperaturę i żar, Pomiar bezpośredni i pośredni * | PN-EN 62115 | PN-EN IEC 62115 | PN-EN 60695-11-5 | PN-EN IEC 60695-2-11 | PN-EN 60695-10-2 | PN-EN IEC 60695-2-10 | PN-EN 62208 | PN-EN 16232 | PN-EN 12790-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/05 | PB-DLS/10 E, Wyroby konsumenckie, Zabawki elektryczne, Sprzet elektryczny i elektroniczny, Artykuly dla dzieci, Hustawki dla niemowlat, Lezaczki niemowlece Badania bezpieczenstwa, Wlasciwosci mechaniczne, fizyczne, Wlasciwosci elektryczne, Odpornosc na wysoka temperature i zar, Pomiar bezposredni i posredni * | PN-EN 62115 | PN-EN IEC 62115 | PN-EN 60695-11-5 | PN-EN IEC 60695-2-11 | PN-EN 60695-10-2 | PN-EN IEC 60695-2-10 | PN-EN 62208 | PN-EN 16232 | PN-EN 12790-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek | PB-DLS/05 | PB-DLS/10","categories":["electronics"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Mechanical and physical properties, Electrical properties, Resistance to high temperature and glowing heat, Direct and indirect measurement","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Mechanical and physical properties, Electrical properties, Resistance to high temperature and glowing heat, Direct and indirect measurement Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 62115 | PN-EN IEC 62115 | PN-EN 60695-11-5 | PN-EN IEC 60695-2-11 | PN-EN 60695-10-2 | PN-EN IEC 60695-2-10 | PN-EN 62208 | PN-EN 16232 | PN-EN 12790-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/05 | PB-DLS/10","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 62115 | PN-EN IEC 62115 | PN-EN 60695-11-5 | PN-EN IEC 60695-2-11 | PN-EN 60695-10-2 | PN-EN IEC 60695-2-10 | PN-EN 62208 | PN-EN 16232 | PN-EN 12790-1 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/05 | PB-DLS/10"},{"_id":"6a83b5ecaf14b9c0e7b20e62","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, ceramika, szkło, powierzchnie krzemianowe wyrobów innych niż wyroby ceramiczne oraz surowce do ich produkcji","methodology":"Badania bezpieczeństwa, Zawartość uwalnianego ołowiu i kadmu","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość uwalnianego ołowiu i kadmu\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 1388-1 | PN-EN 1388-2 | PN-B-13210 Dyrektywa Rady 84/500/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich dotyczących wyrobów ceramicznych przeznaczonych do kontaktu ze środkami spożywczymi | Rozporządzenie Ministra Zdrowia w sprawie wykazu substancji, których stosowanie jest dozwolone w procesie wytwarzania lub przetwarzania materiałów i wyrobów z innych tworzyw niż tworzywa sztuczne przeznaczonych do kontaktu z żywnością","norm_bases":["PN-EN 1388-1","PN-EN 1388-2","PN-B-13210 Dyrektywa Rady 84/500/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich dotyczących wyrobów ceramicznych przeznaczonych do kontaktu ze środkami spożywczymi","Rozporządzenie Ministra Zdrowia w sprawie wykazu substancji, których stosowanie jest dozwolone w procesie wytwarzania lub przetwarzania materiałów i wyrobów z innych tworzyw niż tworzywa sztuczne przeznaczonych do kontaktu z żywnością"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, ceramika, szkło, powierzchnie krzemianowe wyrobów innych niż wyroby ceramiczne oraz surowce do ich produkcji Badania bezpieczeństwa, Zawartość uwalnianego ołowiu i kadmu\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 1388-1 | PN-EN 1388-2 | PN-B-13210 Dyrektywa Rady 84/500/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich dotyczących wyrobów ceramicznych przeznaczonych do kontaktu ze środkami spożywczymi | Rozporządzenie Ministra Zdrowia w sprawie wykazu substancji, których stosowanie jest dozwolone w procesie wytwarzania lub przetwarzania materiałów i wyrobów z innych tworzyw niż tworzywa sztuczne przeznaczonych do kontaktu z żywnością E, Wyroby konsumenckie, ceramika, szklo, powierzchnie krzemianowe wyrobow innych niz wyroby ceramiczne oraz surowce do ich produkcji Badania bezpieczenstwa, Zawartosc uwalnianego olowiu i kadmu\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 1388-1 | PN-EN 1388-2 | PN-B-13210 Dyrektywa Rady 84/500/EWG w sprawie zblizenia ustawodawstw Panstw Czlonkowskich dotyczacych wyrobow ceramicznych przeznaczonych do kontaktu ze srodkami spozywczymi | Rozporzadzenie Ministra Zdrowia w sprawie wykazu substancji, ktorych stosowanie jest dozwolone w procesie wytwarzania lub przetwarzania materialow i wyrobow z innych tworzyw niz tworzywa sztuczne przeznaczonych do kontaktu z zywnoscia","categories":["materials","food"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Content of released lead and cadmium","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Content of released lead and cadmium Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 1388-1 | PN-EN 1388-2 | PN-B-13210 Dyrektywa Rady 84/500/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich dotyczących wyrobów ceramicznych przeznaczonych do kontaktu ze środkami spożywczymi | Rozporządzenie Ministra Zdrowia w sprawie wykazu substancji, których stosowanie jest dozwolone w procesie wytwarzania lub przetwarzania materiałów i wyrobów z innych tworzyw niż tworzywa sztuczne przeznaczonych do kontaktu z żywnością","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体质谱法（ICP-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 1388-1 | PN-EN 1388-2 | PN-B-13210 Dyrektywa Rady 84/500/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich dotyczących wyrobów ceramicznych przeznaczonych do kontaktu ze środkami spożywczymi | Rozporządzenie Ministra Zdrowia w sprawie wykazu substancji, których stosowanie jest dozwolone w procesie wytwarzania lub przetwarzania materiałów i wyrobów z innych tworzyw niż tworzywa sztuczne przeznaczonych do kontaktu z żywnością","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e63","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, skórzane, skóropodobne, włókiennicze, wyroby z tworzyw sztucznych oraz surowce do ich produkcji","methodology":"Badania bezpieczeństwa, Zawartość chromu (VI)","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość chromu (VI)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 17075-1 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PN-EN ISO 17075-1","PN-EN ISO 13688","PN-EN 420","PN-EN ISO 20345 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej","Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, skórzane, skóropodobne, włókiennicze, wyroby z tworzyw sztucznych oraz surowce do ich produkcji Badania bezpieczeństwa, Zawartość chromu (VI)\nMetoda spektrofotometryczna PN-EN ISO 17075-1 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby konsumenckie, skorzane, skoropodobne, wlokiennicze, wyroby z tworzyw sztucznych oraz surowce do ich produkcji Badania bezpieczenstwa, Zawartosc chromu (VI)\nMetoda spektrofotometryczna PN-EN ISO 17075-1 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 Dyrektywa Rady 89/686/EWG w sprawie zblizenia ustawodawstw Panstw Czlonkowskich odnoszacych sie do wyposazenia ochrony osobistej | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie srodkow ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Chromium (VI) content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Chromium (VI) content Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 17075-1 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 17075-1 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"分光光度法"},{"_id":"6a83b5ecaf14b9c0e7b20e64","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, skórzane, skóropodobne, włókiennicze, wyroby z tworzyw sztucznych oraz surowce do ich produkcji, Artykuły dla dzieci, zabawki, farby do malowania palcami","methodology":"Badania bezpieczeństwa, Wartość pH","parameters":[],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Badania bezpieczeństwa, Wartość pH\nMetoda potencjometryczna","reference":"PN-EN ISO 3071 | PN-EN ISO 4045 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 | PN-EN 71-7 | PB-DLS/47 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG","norm_bases":["PN-EN ISO 3071","PN-EN ISO 4045","PN-EN ISO 13688","PN-EN 420","PN-EN ISO 20345","PN-EN 71-7","PB-DLS/47 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej","Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, skórzane, skóropodobne, włókiennicze, wyroby z tworzyw sztucznych oraz surowce do ich produkcji, Artykuły dla dzieci, zabawki, farby do malowania palcami Badania bezpieczeństwa, Wartość pH\nMetoda potencjometryczna PN-EN ISO 3071 | PN-EN ISO 4045 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 | PN-EN 71-7 | PB-DLS/47 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG E, Wyroby konsumenckie, skorzane, skoropodobne, wlokiennicze, wyroby z tworzyw sztucznych oraz surowce do ich produkcji, Artykuly dla dzieci, zabawki, farby do malowania palcami Badania bezpieczenstwa, Wartosc pH\nMetoda potencjometryczna PN-EN ISO 3071 | PN-EN ISO 4045 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 | PN-EN 71-7 | PB-DLS/47 Dyrektywa Rady 89/686/EWG w sprawie zblizenia ustawodawstw Panstw Czlonkowskich odnoszacych sie do wyposazenia ochrony osobistej | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie srodkow ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, pH value","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, pH value Potentiometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 3071 | PN-EN ISO 4045 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 | PN-EN 71-7 | PB-DLS/47 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG","technique_en":"Potentiometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电位法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 3071 | PN-EN ISO 4045 | PN-EN ISO 13688 | PN-EN 420 | PN-EN ISO 20345 | PN-EN 71-7 | PB-DLS/47 Dyrektywa Rady 89/686/EWG w sprawie zbliżenia ustawodawstw Państw Członkowskich odnoszących się do wyposażenia ochrony osobistej | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2016/425 w sprawie środków ochrony indywidualnej oraz uchylenia dyrektywy Rady 89/686/EWG","technique_zh":"电位法"},{"_id":"6a83b5ecaf14b9c0e7b20e65","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, wyroby z tworzyw sztucznych, gumy, skóry, tkanin, papieru i drewna, wyroby włókiennicze przeznaczone do kontaktu ze skórą, rękawiczki, obuwie lub części obuwia przeznaczone do kontaktu ze skórą, pokrycia ścienne i podłogowe, artykuły pielęgnacyjne dla dzieci, produkty do higieny dla kobiet, pieluszki oraz surowce do ich produkcji","methodology":"Badania bezpieczeństwa, Zawartość organicznych związków cyny","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość organicznych związków cyny\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DLS/46 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PB-DLS/46","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, wyroby z tworzyw sztucznych, gumy, skóry, tkanin, papieru i drewna, wyroby włókiennicze przeznaczone do kontaktu ze skórą, rękawiczki, obuwie lub części obuwia przeznaczone do kontaktu ze skórą, pokrycia ścienne i podłogowe, artykuły pielęgnacyjne dla dzieci, produkty do higieny dla kobiet, pieluszki oraz surowce do ich produkcji Badania bezpieczeństwa, Zawartość organicznych związków cyny\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DLS/46 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby konsumenckie, wyroby z tworzyw sztucznych, gumy, skory, tkanin, papieru i drewna, wyroby wlokiennicze przeznaczone do kontaktu ze skora, rekawiczki, obuwie lub czesci obuwia przeznaczone do kontaktu ze skora, pokrycia scienne i podlogowe, artykuly pielegnacyjne dla dzieci, produkty do higieny dla kobiet, pieluszki oraz surowce do ich produkcji Badania bezpieczenstwa, Zawartosc organicznych zwiazkow cyny\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DLS/46 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Content of organotin compounds","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Content of organotin compounds Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/46 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/46 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e66","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, wyroby przeznaczone do kontaktu z żywnością, zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, wyroby polimerowe i gumowe oraz surowce do ich produkcji","methodology":"Badania bezpieczeństwa, Zawartość bisfenolu A – BPA","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość bisfenolu A – BPA\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PB-DLS/50 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PB-DLS/50","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, wyroby przeznaczone do kontaktu z żywnością, zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, wyroby polimerowe i gumowe oraz surowce do ich produkcji Badania bezpieczeństwa, Zawartość bisfenolu A – BPA\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PB-DLS/50 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby konsumenckie, wyroby przeznaczone do kontaktu z zywnoscia, zabawki i artykuly dla dzieci, materialy na zabawki i na artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, wyroby polimerowe i gumowe oraz surowce do ich produkcji Badania bezpieczenstwa, Zawartosc bisfenolu A – BPA\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PB-DLS/50 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["materials","food"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Bisphenol A – BPA content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Bisphenol A – BPA content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/50 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-串联质谱法（GC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/50 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e67","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, artykuły dla dzieci, zabawki na bazie wody, farby do malowania palcami, farby hobbystyczne, płyny do baniek, płyny w zabawkach, kosmetyki oraz surowce do ich produkcji","methodology":"Badania bezpieczeństwa, Zawartość konserwantów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN 71-10 | PN-EN 71-11 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie Parlamentu Europejskiego i Rady (WE) nr 1223/2009 dotyczące produktów kosmetycznych","norm_bases":["PN-EN 71-10","PN-EN 71-11 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","Rozporządzenie Parlamentu Europejskiego i Rady (WE) nr 1223/2009 dotyczące produktów kosmetycznych"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, artykuły dla dzieci, zabawki na bazie wody, farby do malowania palcami, farby hobbystyczne, płyny do baniek, płyny w zabawkach, kosmetyki oraz surowce do ich produkcji Badania bezpieczeństwa, Zawartość konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-EN 71-10 | PN-EN 71-11 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie Parlamentu Europejskiego i Rady (WE) nr 1223/2009 dotyczące produktów kosmetycznych E, Wyroby konsumenckie, artykuly dla dzieci, zabawki na bazie wody, farby do malowania palcami, farby hobbystyczne, plyny do baniek, plyny w zabawkach, kosmetyki oraz surowce do ich produkcji Badania bezpieczenstwa, Zawartosc konserwantow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-EN 71-10 | PN-EN 71-11 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek | Rozporzadzenie Parlamentu Europejskiego i Rady (WE) nr 1223/2009 dotyczace produktow kosmetycznych","categories":["water","pharma"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Preservative content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Preservative content High-performance liquid chromatography with diode array detection (HPLC-DAD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-10 | PN-EN 71-11 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie Parlamentu Europejskiego i Rady (WE) nr 1223/2009 dotyczące produktów kosmetycznych","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-10 | PN-EN 71-11 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie Parlamentu Europejskiego i Rady (WE) nr 1223/2009 dotyczące produktów kosmetycznych","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a83b5ecaf14b9c0e7b20e68","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Sprzęt rekreacyjny i sportowy, Wyposażenie placów zabaw, Huśtawki, zjeżdżalnie, karuzele, urządzenia kołyszące, całkowicie obudowane urządzenia do zabawy, sieci przestrzenne i inne, Siłownie zewnętrzne","methodology":"Właściwości mechaniczne i fizyczne +, Pomiar bezpośredni i pośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Właściwości mechaniczne i fizyczne +, Pomiar bezpośredni i pośredni","reference":"* | PN-EN 1176-1 | PN-EN 1176-2 | PN-EN 1176-3 | PN-EN 1176-5 | PN-EN 1176-6 | PN-EN 1176-10 | PN-EN 1176-11 | PN-EN 16630 | PB-DLS/11","norm_bases":["*","PN-EN 1176-1","PN-EN 1176-2","PN-EN 1176-3","PN-EN 1176-5","PN-EN 1176-6","PN-EN 1176-10","PN-EN 1176-11","PN-EN 16630","PB-DLS/11"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nBadania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Sprzęt rekreacyjny i sportowy, Wyposażenie placów zabaw, Huśtawki, zjeżdżalnie, karuzele, urządzenia kołyszące, całkowicie obudowane urządzenia do zabawy, sieci przestrzenne i inne, Siłownie zewnętrzne Właściwości mechaniczne i fizyczne +, Pomiar bezpośredni i pośredni * | PN-EN 1176-1 | PN-EN 1176-2 | PN-EN 1176-3 | PN-EN 1176-5 | PN-EN 1176-6 | PN-EN 1176-10 | PN-EN 1176-11 | PN-EN 16630 | PB-DLS/11 E, Sprzet rekreacyjny i sportowy, Wyposazenie placow zabaw, Hustawki, zjezdzalnie, karuzele, urzadzenia kolyszace, calkowicie obudowane urzadzenia do zabawy, sieci przestrzenne i inne, Silownie zewnetrzne Wlasciwosci mechaniczne i fizyczne +, Pomiar bezposredni i posredni * | PN-EN 1176-1 | PN-EN 1176-2 | PN-EN 1176-3 | PN-EN 1176-5 | PN-EN 1176-6 | PN-EN 1176-10 | PN-EN 1176-11 | PN-EN 16630 | PB-DLS/11","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mechanical and physical properties +, Direct and indirect measurement","regulatory_area_en":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Mechanical and physical properties +, Direct and indirect measurement + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 1176-1 | PN-EN 1176-2 | PN-EN 1176-3 | PN-EN 1176-5 | PN-EN 1176-6 | PN-EN 1176-10 | PN-EN 1176-11 | PN-EN 16630 | PB-DLS/11","regulatory_area_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 1176-1 | PN-EN 1176-2 | PN-EN 1176-3 | PN-EN 1176-5 | PN-EN 1176-6 | PN-EN 1176-10 | PN-EN 1176-11 | PN-EN 16630 | PB-DLS/11"},{"_id":"6a83b5ecaf14b9c0e7b20e69","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Sprzęt rekreacyjny i sportowy, Nawierzchnie amortyzujące upadki","methodology":"Wysokość krytyczna upadku, Pomiar HIC","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wysokość krytyczna upadku, Pomiar HIC","reference":"* | PN-EN 1177 | PB-DLS/11","norm_bases":["*","PN-EN 1177","PB-DLS/11"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nBadania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Sprzęt rekreacyjny i sportowy, Nawierzchnie amortyzujące upadki Wysokość krytyczna upadku, Pomiar HIC * | PN-EN 1177 | PB-DLS/11 E, Sprzet rekreacyjny i sportowy, Nawierzchnie amortyzujace upadki Wysokosc krytyczna upadku, Pomiar HIC * | PN-EN 1177 | PB-DLS/11","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Critical fall height, HIC measurement","regulatory_area_en":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Critical fall height, HIC measurement + Badania wykonywane w siedzibie i poza siedzibą laboratorium\nTests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 1177 | PB-DLS/11","regulatory_area_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium\n实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 1177 | PB-DLS/11"},{"_id":"6a83b5ecaf14b9c0e7b20e6a","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Artykuły dla dzieci, Smoczki do uspokajania niemowląt i małych dzieci, Sprzęt do picia, Wyroby do mocowania smoczka, Sztućce i naczynia do karmienia, Nosidełka, nosidełka plecakowe, Chodziki, Gondole i stojaki, Leżaczki niemowlęce, Wózki dziecięce, Przewijaki, wanienki, pomoce do kąpieli, Kojce, Bujaki, Foteliki rowerowe, Wysokie krzesełka, siedziska, Huśtawki dla niemowląt, Barierki bezpieczeństwa, Łóżka dziecięce, łóżeczka i kołyski mieszkaniowe, łóżka piętrowe i łóżka wysokie, materace, ochraniacze, śpiwory, kołdry, Szelki, lejce i podobne artykuły","methodology":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","reference":"* | PN-EN 1400 | PN-EN 14350 | PN-EN 12586 | PN-EN 14372 | PN-EN 13209-1 | PN-EN 13209-2 PKN-CEN/TR 16512 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 12790-2 | PN-EN 1888-1 | PN-EN 1888-2 AS/NZS 2088 | PN-EN 12221-1 | PN-EN 12221-2 | PN-EN 17022 | PN-EN 17072 | PN-EN 12227 | PN-EN 14036 | PN-EN 14344 | PN-EN 14988 | PN-EN 71-1 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 716-2 | PN-EN 1130 | PN-EN 747-1 | PN-EN 747-2 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-1 | PN-EN 13210-2 Consumer Goods (Baby Bath Aids) Safety Standard | ASTM F1967 | PB-DLS/05 | PB-DLS/17 | PB-DLS/30","norm_bases":["*","PN-EN 1400","PN-EN 14350","PN-EN 12586","PN-EN 14372","PN-EN 13209-1","PN-EN 13209-2 PKN-CEN/TR 16512","PN-EN 1273","PN-EN 1466","PN-EN 12790","PN-EN 12790-1","PN-EN 12790-2","PN-EN 1888-1","PN-EN 1888-2 AS/NZS 2088","PN-EN 12221-1","PN-EN 12221-2","PN-EN 17022","PN-EN 17072","PN-EN 12227","PN-EN 14036","PN-EN 14344","PN-EN 14988","PN-EN 71-1","PN-EN 17191","PN-EN 16232","PN-EN 1930","PN-EN 716-1","PN-EN 716-2","PN-EN 1130","PN-EN 747-1","PN-EN 747-2","PN-EN 16890","PN-EN 16780","PN-EN 16781","PN-EN 16779-1","PN-EN 13210-1","PN-EN 13210-2 Consumer Goods (Baby Bath Aids) Safety Standard","ASTM F1967","PB-DLS/05","PB-DLS/17","PB-DLS/30"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Artykuły dla dzieci, Smoczki do uspokajania niemowląt i małych dzieci, Sprzęt do picia, Wyroby do mocowania smoczka, Sztućce i naczynia do karmienia, Nosidełka, nosidełka plecakowe, Chodziki, Gondole i stojaki, Leżaczki niemowlęce, Wózki dziecięce, Przewijaki, wanienki, pomoce do kąpieli, Kojce, Bujaki, Foteliki rowerowe, Wysokie krzesełka, siedziska, Huśtawki dla niemowląt, Barierki bezpieczeństwa, Łóżka dziecięce, łóżeczka i kołyski mieszkaniowe, łóżka piętrowe i łóżka wysokie, materace, ochraniacze, śpiwory, kołdry, Szelki, lejce i podobne artykuły Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni * | PN-EN 1400 | PN-EN 14350 | PN-EN 12586 | PN-EN 14372 | PN-EN 13209-1 | PN-EN 13209-2 PKN-CEN/TR 16512 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 12790-2 | PN-EN 1888-1 | PN-EN 1888-2 AS/NZS 2088 | PN-EN 12221-1 | PN-EN 12221-2 | PN-EN 17022 | PN-EN 17072 | PN-EN 12227 | PN-EN 14036 | PN-EN 14344 | PN-EN 14988 | PN-EN 71-1 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 716-2 | PN-EN 1130 | PN-EN 747-1 | PN-EN 747-2 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-1 | PN-EN 13210-2 Consumer Goods (Baby Bath Aids) Safety Standard | ASTM F1967 | PB-DLS/05 | PB-DLS/17 | PB-DLS/30 E, Artykuly dla dzieci, Smoczki do uspokajania niemowlat i malych dzieci, Sprzet do picia, Wyroby do mocowania smoczka, Sztucce i naczynia do karmienia, Nosidelka, nosidelka plecakowe, Chodziki, Gondole i stojaki, Lezaczki niemowlece, Wozki dzieciece, Przewijaki, wanienki, pomoce do kapieli, Kojce, Bujaki, Foteliki rowerowe, Wysokie krzeselka, siedziska, Hustawki dla niemowlat, Barierki bezpieczenstwa, Lozka dzieciece, lozeczka i kolyski mieszkaniowe, lozka pietrowe i lozka wysokie, materace, ochraniacze, spiwory, koldry, Szelki, lejce i podobne artykuly Badania bezpieczenstwa, Wlasciwosci mechaniczne i fizyczne, Pomiar bezposredni i posredni * | PN-EN 1400 | PN-EN 14350 | PN-EN 12586 | PN-EN 14372 | PN-EN 13209-1 | PN-EN 13209-2 PKN-CEN/TR 16512 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 12790-2 | PN-EN 1888-1 | PN-EN 1888-2 AS/NZS 2088 | PN-EN 12221-1 | PN-EN 12221-2 | PN-EN 17022 | PN-EN 17072 | PN-EN 12227 | PN-EN 14036 | PN-EN 14344 | PN-EN 14988 | PN-EN 71-1 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 716-2 | PN-EN 1130 | PN-EN 747-1 | PN-EN 747-2 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-1 | PN-EN 13210-2 Consumer Goods (Baby Bath Aids) Safety Standard | ASTM F1967 | PB-DLS/05 | PB-DLS/17 | PB-DLS/30","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 1400 | PN-EN 14350 | PN-EN 12586 | PN-EN 14372 | PN-EN 13209-1 | PN-EN 13209-2 PKN-CEN/TR 16512 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 12790-2 | PN-EN 1888-1 | PN-EN 1888-2 AS/NZS 2088 | PN-EN 12221-1 | PN-EN 12221-2 | PN-EN 17022 | PN-EN 17072 | PN-EN 12227 | PN-EN 14036 | PN-EN 14344 | PN-EN 14988 | PN-EN 71-1 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 716-2 | PN-EN 1130 | PN-EN 747-1 | PN-EN 747-2 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-1 | PN-EN 13210-2 Consumer Goods (Baby Bath Aids) Safety Standard | ASTM F1967 | PB-DLS/05 | PB-DLS/17 | PB-DLS/30","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"安全性检验、机械与物理性能、直接与间接测量 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 1400 | PN-EN 14350 | PN-EN 12586 | PN-EN 14372 | PN-EN 13209-1 | PN-EN 13209-2 PKN-CEN/TR 16512 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 12790-2 | PN-EN 1888-1 | PN-EN 1888-2 AS/NZS 2088 | PN-EN 12221-1 | PN-EN 12221-2 | PN-EN 17022 | PN-EN 17072 | PN-EN 12227 | PN-EN 14036 | PN-EN 14344 | PN-EN 14988 | PN-EN 71-1 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 716-2 | PN-EN 1130 | PN-EN 747-1 | PN-EN 747-2 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-1 | PN-EN 13210-2 Consumer Goods (Baby Bath Aids) Safety Standard | ASTM F1967 | PB-DLS/05 | PB-DLS/17 | PB-DLS/30","methodology_zh":"安全性检验、机械与物理性能、直接与间接测量"},{"_id":"6a83b5ecaf14b9c0e7b20e6b","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Artykuły dla dzieci, Materiały na artykuły dla dzieci, Nosidełka, nosidełka plecakowe i materiały na nosidełka, Chodziki i materiały na chodziki, Gondole i stojaki oraz materiały na gondole i stojaki, Leżaczki niemowlęce i materiały na leżaczki niemowlęce, Wózki dziecięce i materiały na wózki dziecięce, Przewijaki i materiały na przewijaki, Kojce i materiały na kojce, Bujaki i materiały na bujaki, Wysokie krzesełka, siedziska i materiały na wysokie krzesełka, siedziska, Huśtawki dla niemowląt i materiały na huśtawki dla niemowląt, Barierki bezpieczeństwa i materiały na barierki bezpieczeństwa, Łóżka dziecięce, łóżeczka, kołyski mieszkaniowe, materace, ochraniacze, śpiwory, kołdry, szelki, lejce, materiały na łóżka dziecięce, łóżeczka, kołyski mieszkaniowe, materace, ochraniacze i śpiwory, kołdry, szelki, lejce, Foteliki rowerowe i materiały na foteliki rowerowe","methodology":"Badania bezpieczeństwa, Palność, Próba palności","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Palność, Próba palności","reference":"* | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1888-1 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 14036 | PN-EN 14988 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 1130 | PN-EN 16890 | PN-EN 16780) | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-2 | PN-EN 14344 | PN-EN 71-2 | EN 71-2 PKN-CEN/TR 16512 | PB-DLS/06 | PB-DLS/17 | PB-DLS/30","norm_bases":["*","PN-EN 13209-1","PN-EN 13209-2","PN-EN 1273","PN-EN 1466","PN-EN 12790","PN-EN 12790-1","PN-EN 1888-1","PN-EN 12221-1","PN-EN 12227","PN-EN 14036","PN-EN 14988","PN-EN 17191","PN-EN 16232","PN-EN 1930","PN-EN 716-1","PN-EN 1130","PN-EN 16890","PN-EN 16780)","PN-EN 16781","PN-EN 16779-1","PN-EN 13210-2","PN-EN 14344","PN-EN 71-2","EN 71-2 PKN-CEN/TR 16512","PB-DLS/06","PB-DLS/17","PB-DLS/30"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Artykuły dla dzieci, Materiały na artykuły dla dzieci, Nosidełka, nosidełka plecakowe i materiały na nosidełka, Chodziki i materiały na chodziki, Gondole i stojaki oraz materiały na gondole i stojaki, Leżaczki niemowlęce i materiały na leżaczki niemowlęce, Wózki dziecięce i materiały na wózki dziecięce, Przewijaki i materiały na przewijaki, Kojce i materiały na kojce, Bujaki i materiały na bujaki, Wysokie krzesełka, siedziska i materiały na wysokie krzesełka, siedziska, Huśtawki dla niemowląt i materiały na huśtawki dla niemowląt, Barierki bezpieczeństwa i materiały na barierki bezpieczeństwa, Łóżka dziecięce, łóżeczka, kołyski mieszkaniowe, materace, ochraniacze, śpiwory, kołdry, szelki, lejce, materiały na łóżka dziecięce, łóżeczka, kołyski mieszkaniowe, materace, ochraniacze i śpiwory, kołdry, szelki, lejce, Foteliki rowerowe i materiały na foteliki rowerowe Badania bezpieczeństwa, Palność, Próba palności * | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1888-1 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 14036 | PN-EN 14988 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 1130 | PN-EN 16890 | PN-EN 16780) | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-2 | PN-EN 14344 | PN-EN 71-2 | EN 71-2 PKN-CEN/TR 16512 | PB-DLS/06 | PB-DLS/17 | PB-DLS/30 E, Artykuly dla dzieci, Materialy na artykuly dla dzieci, Nosidelka, nosidelka plecakowe i materialy na nosidelka, Chodziki i materialy na chodziki, Gondole i stojaki oraz materialy na gondole i stojaki, Lezaczki niemowlece i materialy na lezaczki niemowlece, Wozki dzieciece i materialy na wozki dzieciece, Przewijaki i materialy na przewijaki, Kojce i materialy na kojce, Bujaki i materialy na bujaki, Wysokie krzeselka, siedziska i materialy na wysokie krzeselka, siedziska, Hustawki dla niemowlat i materialy na hustawki dla niemowlat, Barierki bezpieczenstwa i materialy na barierki bezpieczenstwa, Lozka dzieciece, lozeczka, kolyski mieszkaniowe, materace, ochraniacze, spiwory, koldry, szelki, lejce, materialy na lozka dzieciece, lozeczka, kolyski mieszkaniowe, materace, ochraniacze i spiwory, koldry, szelki, lejce, Foteliki rowerowe i materialy na foteliki rowerowe Badania bezpieczenstwa, Palnosc, Proba palnosci * | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1888-1 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 14036 | PN-EN 14988 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 1130 | PN-EN 16890 | PN-EN 16780) | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-2 | PN-EN 14344 | PN-EN 71-2 | EN 71-2 PKN-CEN/TR 16512 | PB-DLS/06 | PB-DLS/17 | PB-DLS/30","categories":["materials"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety tests, Flammability, Flammability test","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety tests, Flammability, Flammability test Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1888-1 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 14036 | PN-EN 14988 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 1130 | PN-EN 16890 | PN-EN 16780) | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-2 | PN-EN 14344 | PN-EN 71-2 | EN 71-2 PKN-CEN/TR 16512 | PB-DLS/06 | PB-DLS/17 | PB-DLS/30","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 1273 | PN-EN 1466 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1888-1 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 14036 | PN-EN 14988 | PN-EN 17191 | PN-EN 16232 | PN-EN 1930 | PN-EN 716-1 | PN-EN 1130 | PN-EN 16890 | PN-EN 16780) | PN-EN 16781 | PN-EN 16779-1 | PN-EN 13210-2 | PN-EN 14344 | PN-EN 71-2 | EN 71-2 PKN-CEN/TR 16512 | PB-DLS/06 | PB-DLS/17 | PB-DLS/30"},{"_id":"6a83b5ecaf14b9c0e7b20e6c","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, Opakowania zabawek, Artykuły dla dzieci, Hulajnogi, Wyroby konsumenckie, Świece, Okulary do pływania, Maski do nurkowania","methodology":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","reference":"PN-EN 71-1 * | ASTM F963 | ISO 8124-1 | PN-EN 14682 | PN-EN 14619 | PN-EN 17128 | PN-EN 15493 | PN-EN 17616 | PN-EN 16805 | ISO 18527-3 | PB-DLS/05 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 71-1 *","ASTM F963","ISO 8124-1","PN-EN 14682","PN-EN 14619","PN-EN 17128","PN-EN 15493","PN-EN 17616","PN-EN 16805","ISO 18527-3","PB-DLS/05","PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, Opakowania zabawek, Artykuły dla dzieci, Hulajnogi, Wyroby konsumenckie, Świece, Okulary do pływania, Maski do nurkowania Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni PN-EN 71-1 * | ASTM F963 | ISO 8124-1 | PN-EN 14682 | PN-EN 14619 | PN-EN 17128 | PN-EN 15493 | PN-EN 17616 | PN-EN 16805 | ISO 18527-3 | PB-DLS/05 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, Opakowania zabawek, Artykuly dla dzieci, Hulajnogi, Wyroby konsumenckie, Swiece, Okulary do plywania, Maski do nurkowania Badania bezpieczenstwa, Wlasciwosci mechaniczne i fizyczne, Pomiar bezposredni i posredni PN-EN 71-1 * | ASTM F963 | ISO 8124-1 | PN-EN 14682 | PN-EN 14619 | PN-EN 17128 | PN-EN 15493 | PN-EN 17616 | PN-EN 16805 | ISO 18527-3 | PB-DLS/05 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-1 * | ASTM F963 | ISO 8124-1 | PN-EN 14682 | PN-EN 14619 | PN-EN 17128 | PN-EN 15493 | PN-EN 17616 | PN-EN 16805 | ISO 18527-3 | PB-DLS/05 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"安全性检验、机械与物理性能、直接与间接测量 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-1 * | ASTM F963 | ISO 8124-1 | PN-EN 14682 | PN-EN 14619 | PN-EN 17128 | PN-EN 15493 | PN-EN 17616 | PN-EN 16805 | ISO 18527-3 | PB-DLS/05 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","methodology_zh":"安全性检验、机械与物理性能、直接与间接测量"},{"_id":"6a83b5ecaf14b9c0e7b20e6d","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, Artykuły dla dzieci, Wyroby konsumenckie, Materiały na zabawki, artykuły dla dzieci, wyroby konsumenckie, Świece","methodology":"Badania bezpieczeństwa, Palność, Próba palności","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Palność, Próba palności","reference":"PN-EN 71-2 * | EN 71-2 | PN-EN 15493 | PN-EN 17616 | PB-DLS/06 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 71-2 *","EN 71-2","PN-EN 15493","PN-EN 17616","PB-DLS/06","PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, Artykuły dla dzieci, Wyroby konsumenckie, Materiały na zabawki, artykuły dla dzieci, wyroby konsumenckie, Świece Badania bezpieczeństwa, Palność, Próba palności PN-EN 71-2 * | EN 71-2 | PN-EN 15493 | PN-EN 17616 | PB-DLS/06 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, Artykuly dla dzieci, Wyroby konsumenckie, Materialy na zabawki, artykuly dla dzieci, wyroby konsumenckie, Swiece Badania bezpieczenstwa, Palnosc, Proba palnosci PN-EN 71-2 * | EN 71-2 | PN-EN 15493 | PN-EN 17616 | PB-DLS/06 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety tests, Flammability, Flammability test","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety tests, Flammability, Flammability test Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-2 * | EN 71-2 | PN-EN 15493 | PN-EN 17616 | PB-DLS/06 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-2 * | EN 71-2 | PN-EN 15493 | PN-EN 17616 | PB-DLS/06 | PB-DLS/17 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"},{"_id":"6a83b5ecaf14b9c0e7b20e6e","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki aktywizujące przeznaczone do użytku domowego","methodology":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","reference":"PN-EN 71-8 * Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/07","norm_bases":["PN-EN 71-8 * Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","PB-DLS/07"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki aktywizujące przeznaczone do użytku domowego Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni PN-EN 71-8 * Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/07 E, Zabawki aktywizujace przeznaczone do uzytku domowego Badania bezpieczenstwa, Wlasciwosci mechaniczne i fizyczne, Pomiar bezposredni i posredni PN-EN 71-8 * Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek | PB-DLS/07","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-8 * Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/07","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"安全性检验、机械与物理性能、直接与间接测量 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-8 * Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | PB-DLS/07","methodology_zh":"安全性检验、机械与物理性能、直接与间接测量"},{"_id":"6a83b5ecaf14b9c0e7b20e6f","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Odzież dziecięca","methodology":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","reference":"* | PN-EN 14682 | PB-DLS/17","norm_bases":["*","PN-EN 14682","PB-DLS/17"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Odzież dziecięca Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni * | PN-EN 14682 | PB-DLS/17 E, Odziez dziecieca Badania bezpieczenstwa, Wlasciwosci mechaniczne i fizyczne, Pomiar bezposredni i posredni * | PN-EN 14682 | PB-DLS/17","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 14682 | PB-DLS/17","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"安全性检验、机械与物理性能、直接与间接测量 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 14682 | PB-DLS/17","methodology_zh":"安全性检验、机械与物理性能、直接与间接测量"},{"_id":"6a83b5ecaf14b9c0e7b20e70","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, Grille opalane paliwami stałymi, Grille jednorazowego użytku na paliwo stałe, Podpałki do rozpalania paliw stałych","methodology":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni","reference":"* | PN-EN 1860-1 | PN-EN 1860-3 | PN-EN 1860-4 | PN-EN 71-1 | PB-DLS/35","norm_bases":["*","PN-EN 1860-1","PN-EN 1860-3","PN-EN 1860-4","PN-EN 71-1","PB-DLS/35"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, Grille opalane paliwami stałymi, Grille jednorazowego użytku na paliwo stałe, Podpałki do rozpalania paliw stałych Badania bezpieczeństwa, Właściwości mechaniczne i fizyczne, Pomiar bezpośredni i pośredni * | PN-EN 1860-1 | PN-EN 1860-3 | PN-EN 1860-4 | PN-EN 71-1 | PB-DLS/35 E, Wyroby konsumenckie, Grille opalane paliwami stalymi, Grille jednorazowego uzytku na paliwo stale, Podpalki do rozpalania paliw stalych Badania bezpieczenstwa, Wlasciwosci mechaniczne i fizyczne, Pomiar bezposredni i posredni * | PN-EN 1860-1 | PN-EN 1860-3 | PN-EN 1860-4 | PN-EN 71-1 | PB-DLS/35","categories":["petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Mechanical and physical properties, Direct and indirect measurement Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 1860-1 | PN-EN 1860-3 | PN-EN 1860-4 | PN-EN 71-1 | PB-DLS/35","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"安全性检验、机械与物理性能、直接与间接测量 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 1860-1 | PN-EN 1860-3 | PN-EN 1860-4 | PN-EN 71-1 | PB-DLS/35","methodology_zh":"安全性检验、机械与物理性能、直接与间接测量"},{"_id":"6a83b5ecaf14b9c0e7b20e71","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby tekstylne, włókiennicze, odzież, odzież ochronna","methodology":"Odporność wybarwień na działanie wody","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność wybarwień na działanie wody","reference":"PN-EN ISO 105-E01","norm_bases":["PN-EN ISO 105-E01"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby tekstylne, włókiennicze, odzież, odzież ochronna Odporność wybarwień na działanie wody PN-EN ISO 105-E01 E, Wyroby tekstylne, wlokiennicze, odziez, odziez ochronna Odpornosc wybarwien na dzialanie wody PN-EN ISO 105-E01","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour fastness to water","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Colour fastness to water E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 105-E01","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"染色耐水作用牢度 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 105-E01","methodology_zh":"染色耐水作用牢度"},{"_id":"6a83b5ecaf14b9c0e7b20e72","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby tekstylne, włókiennicze, odzież, odzież ochronna","methodology":"Odporność wybarwień na działanie potu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność wybarwień na działanie potu","reference":"PN-EN ISO 105-E04","norm_bases":["PN-EN ISO 105-E04"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby tekstylne, włókiennicze, odzież, odzież ochronna Odporność wybarwień na działanie potu PN-EN ISO 105-E04 E, Wyroby tekstylne, wlokiennicze, odziez, odziez ochronna Odpornosc wybarwien na dzialanie potu PN-EN ISO 105-E04","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour fastness to perspiration","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Colour fastness to perspiration E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 105-E04","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 105-E04"},{"_id":"6a83b5ecaf14b9c0e7b20e73","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby tekstylne, zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci","methodology":"Odporność wybarwień na działanie potu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność wybarwień na działanie potu","reference":"PN-EN ISO 105-E04 | PN-EN 71-10 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 16890","norm_bases":["PN-EN ISO 105-E04","PN-EN 71-10","PN-EN 16781","PN-EN 16779-1","PN-EN 16780","PN-EN 16890"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby tekstylne, zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci Odporność wybarwień na działanie potu PN-EN ISO 105-E04 | PN-EN 71-10 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 16890 E, Wyroby tekstylne, zabawki, artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci Odpornosc wybarwien na dzialanie potu PN-EN ISO 105-E04 | PN-EN 71-10 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 16890","categories":["materials"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour fastness to perspiration","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Colour fastness to perspiration E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 105-E04 | PN-EN 71-10 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 16890","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 105-E04 | PN-EN 71-10 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 16890"},{"_id":"6a83b5ecaf14b9c0e7b20e74","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, materiały na zabawki, tworzywa sztuczne, gumy *","methodology":"Migracja plastyfikatorów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Migracja plastyfikatorów\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11","norm_bases":["PN-EN 71-9","PN-EN 71-10","PN-EN 71-11"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, materiały na zabawki, tworzywa sztuczne, gumy * Migracja plastyfikatorów\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 E, Zabawki, materialy na zabawki, tworzywa sztuczne, gumy * Migracja plastyfikatorow\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11","categories":["materials"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of plasticisers","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Migration of plasticisers Gas chromatography with mass spectrometry detection (GC-MS) Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e75","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, wyroby do mocowania smoczka, chodziki, huśtawki dla niemowląt, gondole, leżaczki niemowlęce, materiały na zabawki i na artykuły dla dzieci, Farby, wyroby tekstylne, skóra, papier, tworzywa sztuczne, gumy, drewno,","methodology":"Zawartość barwników","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość barwników\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1273 | PN-EN 16232 | PN-EN 12790-1 | PN-EN 1466","norm_bases":["PN-EN 71-9","PN-EN 71-10","PN-EN 71-11","PN-EN 12586","PN-EN 1273","PN-EN 16232","PN-EN 12790-1","PN-EN 1466"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, wyroby do mocowania smoczka, chodziki, huśtawki dla niemowląt, gondole, leżaczki niemowlęce, materiały na zabawki i na artykuły dla dzieci, Farby, wyroby tekstylne, skóra, papier, tworzywa sztuczne, gumy, drewno, Zawartość barwników\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1273 | PN-EN 16232 | PN-EN 12790-1 | PN-EN 1466 E, Zabawki, artykuly dla dzieci, wyroby do mocowania smoczka, chodziki, hustawki dla niemowlat, gondole, lezaczki niemowlece, materialy na zabawki i na artykuly dla dzieci, Farby, wyroby tekstylne, skora, papier, tworzywa sztuczne, gumy, drewno, Zawartosc barwnikow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1273 | PN-EN 16232 | PN-EN 12790-1 | PN-EN 1466","categories":["materials"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colourant content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Colourant content High-performance liquid chromatography with diode array detection (HPLC-DAD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1273 | PN-EN 16232 | PN-EN 12790-1 | PN-EN 1466","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"着色剂含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1273 | PN-EN 16232 | PN-EN 12790-1 | PN-EN 1466","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"着色剂含量"},{"_id":"6a83b5ecaf14b9c0e7b20e76","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby z tworzyw sztucznych, farby, tworzywa sztuczne, wyroby metalowe, skóra, wyroby skóropodobne, materiały włókiennicze, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby jubilerskie, biżuteria, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość Cd","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość Cd\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-DLS/14 | PB-DLS/29 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PB-DLS/14","PB-DLS/29","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby z tworzyw sztucznych, farby, tworzywa sztuczne, wyroby metalowe, skóra, wyroby skóropodobne, materiały włókiennicze, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby jubilerskie, biżuteria, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość Cd\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-DLS/14 | PB-DLS/29 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby z tworzyw sztucznych, farby, tworzywa sztuczne, wyroby metalowe, skora, wyroby skoropodobne, materialy wlokiennicze, Zabawki, artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Wyroby jubilerskie, bizuteria, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc Cd\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-DLS/14 | PB-DLS/29 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["materials","petro"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Cd content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Cd content Inductively coupled plasma optical emission spectrometry (ICP-OES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/14 | PB-DLS/29 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/14 | PB-DLS/29 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83b5ecaf14b9c0e7b20e77","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego, Elementy polimerowe, papierowe tekstylne artykułów dla dzieci, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"* | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-6 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym","norm_bases":["*","PN-EN 62321","PN-EN 62321-1","PN-EN 62321-6 Dyrektywa 2011/65/UE – RoHS","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego, Elementy polimerowe, papierowe tekstylne artykułów dla dzieci, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość polibromowanych bifenyli (PBB) i polibromowanych eterów difenylowych (PBDE)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-6 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym E, Sprzet elektryczny i elektroniczny oraz jego elementy polimerowe, tekstylne, papierowe i elektroniczne, materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego, Elementy polimerowe, papierowe tekstylne artykulow dla dzieci, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc polibromowanych bifenyli (PBB) i polibromowanych eterow difenylowych (PBDE)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-6 Dyrektywa 2011/65/UE – RoHS | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporzadzenie Ministra Rozwoju i Finansow z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagan dotyczacych ograniczenia stosowania niektorych niebezpiecznych substancji w sprzecie elektrycznym i elektronicznym","categories":["materials","petro","electronics"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Content of polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE)","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Content of polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) Gas chromatography with mass spectrometry detection (GC-MS) Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-6 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-6 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e78","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna\nMetoda wagowa","reference":"* | PN-EN 1186-1 | PN-EN 1186-3 | PN-EN 1186-5 | PN-EN 1186-7 | PN-EN 1186-9 | PN-EN 1186-14 | PN-EN 1186-15 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością","norm_bases":["*","PN-EN 1186-1","PN-EN 1186-3","PN-EN 1186-5","PN-EN 1186-7","PN-EN 1186-9","PN-EN 1186-14","PN-EN 1186-15","Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością Migracja globalna\nMetoda wagowa * | PN-EN 1186-1 | PN-EN 1186-3 | PN-EN 1186-5 | PN-EN 1186-7 | PN-EN 1186-9 | PN-EN 1186-14 | PN-EN 1186-15 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością E, Materialy i wyroby przeznaczone do kontaktu z zywnoscia Migracja globalna\nMetoda wagowa * | PN-EN 1186-1 | PN-EN 1186-3 | PN-EN 1186-5 | PN-EN 1186-7 | PN-EN 1186-9 | PN-EN 1186-14 | PN-EN 1186-15 | Rozporzadzenie Komisji (UE) nr 10/2011 w sprawie materialow i wyrobow z tworzyw sztucznych przeznaczonych do kontaktu z zywnoscia","categories":["materials","food"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Overall migration Gravimetric method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 1186-1 | PN-EN 1186-3 | PN-EN 1186-5 | PN-EN 1186-7 | PN-EN 1186-9 | PN-EN 1186-14 | PN-EN 1186-15 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością","technique_en":"Gravimetric method","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"重量法 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 1186-1 | PN-EN 1186-3 | PN-EN 1186-5 | PN-EN 1186-7 | PN-EN 1186-9 | PN-EN 1186-14 | PN-EN 1186-15 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością","technique_zh":"重量法"},{"_id":"6a83b5ecaf14b9c0e7b20e79","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością","methodology":"Migracja specyficzna bisfenolu A","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Migracja specyficzna bisfenolu A\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-13","norm_bases":["PN-EN 13130-1","Rozporządzenie Komisji (UE) nr 10/2011w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością","PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-13"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością Migracja specyficzna bisfenolu A\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-13 E, Materialy i wyroby przeznaczone do kontaktu z zywnoscia Migracja specyficzna bisfenolu A\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN 13130-1 | Rozporzadzenie Komisji (UE) nr 10/2011w sprawie materialow i wyrobow z tworzyw sztucznych przeznaczonych do kontaktu z zywnoscia | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-13","categories":["materials","food"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specific migration of bisphenol A","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Specific migration of bisphenol A High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-13","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-13","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a83b5ecaf14b9c0e7b20e7a","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, sprzęt do picia, smoczki do uspokajania niemowląt i małych dzieci, tworzywa sztuczne","methodology":"Migracja formaldehydu","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja formaldehydu\nMetoda spektrofotometryczna","reference":"PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 1400 | PN-EN 14350 | Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 71-9","PN-EN 71-10","PN-EN 71-11","PN-EN 1400","PN-EN 14350","Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, sprzęt do picia, smoczki do uspokajania niemowląt i małych dzieci, tworzywa sztuczne Migracja formaldehydu\nMetoda spektrofotometryczna PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 1400 | PN-EN 14350 | Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci, sprzet do picia, smoczki do uspokajania niemowlat i malych dzieci, tworzywa sztuczne Migracja formaldehydu\nMetoda spektrofotometryczna PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 1400 | PN-EN 14350 | Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of formaldehyde","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Migration of formaldehyde Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 1400 | PN-EN 14350 | Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 1400 | PN-EN 14350 | Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"分光光度法"},{"_id":"6a83b5ecaf14b9c0e7b20e7b","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, wyroby włókiennicze i tekstylne, artykuły dla dzieci, wyroby do mocowania smoczka, łóżeczka dziecięce, kołyski, nosidełka, chodziki, huśtawki niemowlęce, ochraniacze, śpiwory, kołdry, gondole, leżaczki niemowlęce","methodology":"Zawartość wolnego i zhydrolizowanego formaldehydu","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość wolnego i zhydrolizowanego formaldehydu\nMetoda spektrofotometryczna","reference":"PN-EN ISO 14184-1 JIS L 1041 | PN-EN 71-9 | PN-EN 12586 | PN-EN 1130 | PN-EN 13209-1 | PN-EN 16232 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 12790-1 | PN-EN 1466 PKN-CEN/TR 16512 | PN-EN 1273 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PN-EN ISO 14184-1 JIS L 1041","PN-EN 71-9","PN-EN 12586","PN-EN 1130","PN-EN 13209-1","PN-EN 16232","PN-EN 16781","PN-EN 16779-1","PN-EN 16780","PN-EN 12790-1","PN-EN 1466 PKN-CEN/TR 16512","PN-EN 1273 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, wyroby włókiennicze i tekstylne, artykuły dla dzieci, wyroby do mocowania smoczka, łóżeczka dziecięce, kołyski, nosidełka, chodziki, huśtawki niemowlęce, ochraniacze, śpiwory, kołdry, gondole, leżaczki niemowlęce Zawartość wolnego i zhydrolizowanego formaldehydu\nMetoda spektrofotometryczna PN-EN ISO 14184-1 JIS L 1041 | PN-EN 71-9 | PN-EN 12586 | PN-EN 1130 | PN-EN 13209-1 | PN-EN 16232 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 12790-1 | PN-EN 1466 PKN-CEN/TR 16512 | PN-EN 1273 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Zabawki, wyroby wlokiennicze i tekstylne, artykuly dla dzieci, wyroby do mocowania smoczka, lozeczka dzieciece, kolyski, nosidelka, chodziki, hustawki niemowlece, ochraniacze, spiwory, koldry, gondole, lezaczki niemowlece Zawartosc wolnego i zhydrolizowanego formaldehydu\nMetoda spektrofotometryczna PN-EN ISO 14184-1 JIS L 1041 | PN-EN 71-9 | PN-EN 12586 | PN-EN 1130 | PN-EN 13209-1 | PN-EN 16232 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 12790-1 | PN-EN 1466 PKN-CEN/TR 16512 | PN-EN 1273 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of free and hydrolysed formaldehyde","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Content of free and hydrolysed formaldehyde Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 14184-1 JIS L 1041 | PN-EN 71-9 | PN-EN 12586 | PN-EN 1130 | PN-EN 13209-1 | PN-EN 16232 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 12790-1 | PN-EN 1466 PKN-CEN/TR 16512 | PN-EN 1273 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 14184-1 JIS L 1041 | PN-EN 71-9 | PN-EN 12586 | PN-EN 1130 | PN-EN 13209-1 | PN-EN 16232 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PN-EN 12790-1 | PN-EN 1466 PKN-CEN/TR 16512 | PN-EN 1273 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"分光光度法"},{"_id":"6a83b5ecaf14b9c0e7b20e7c","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby włókiennicze","methodology":"Zawartość wolnego lub uwalniającego się formaldehydu","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość wolnego lub uwalniającego się formaldehydu\nMetoda spektrofotometryczna","reference":"PN-EN ISO 14184-2 JIS L 1041 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PN-EN ISO 14184-2 JIS L 1041 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby włókiennicze Zawartość wolnego lub uwalniającego się formaldehydu\nMetoda spektrofotometryczna PN-EN ISO 14184-2 JIS L 1041 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby wlokiennicze Zawartosc wolnego lub uwalniajacego sie formaldehydu\nMetoda spektrofotometryczna PN-EN ISO 14184-2 JIS L 1041 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["other"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of free or released formaldehyde","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Content of free or released formaldehyde Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 14184-2 JIS L 1041 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 14184-2 JIS L 1041 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"分光光度法"},{"_id":"6a83b5ecaf14b9c0e7b20e7d","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, wyroby z papieru i tektury przeznaczone do kontaktu z żywnością","methodology":"Zawartość formaldehydu","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu\nMetoda spektrofotometryczna","reference":"PN-EN 71-9 | PN-EN 1541 | PN-EN 645 | PN-EN 647 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 71-9","PN-EN 1541","PN-EN 645","PN-EN 647 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, wyroby z papieru i tektury przeznaczone do kontaktu z żywnością Zawartość formaldehydu\nMetoda spektrofotometryczna PN-EN 71-9 | PN-EN 1541 | PN-EN 645 | PN-EN 647 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, wyroby z papieru i tektury przeznaczone do kontaktu z zywnoscia Zawartosc formaldehydu\nMetoda spektrofotometryczna PN-EN 71-9 | PN-EN 1541 | PN-EN 645 | PN-EN 647 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["food"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Formaldehyde content Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-9 | PN-EN 1541 | PN-EN 645 | PN-EN 647 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"甲醛含量 分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-9 | PN-EN 1541 | PN-EN 645 | PN-EN 647 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"分光光度法","methodology_zh":"甲醛含量"},{"_id":"6a83b5ecaf14b9c0e7b20e7e","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, drewno i płyty drewno- pochodne, artykuły dla dzieci, wyroby do mocowania smoczka","methodology":"Emisja formaldehydu","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Emisja formaldehydu\nMetoda spektrofotometryczna","reference":"PN-EN 717-3 | PN-EN 71-9 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 717-3","PN-EN 71-9","PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, drewno i płyty drewno- pochodne, artykuły dla dzieci, wyroby do mocowania smoczka Emisja formaldehydu\nMetoda spektrofotometryczna PN-EN 717-3 | PN-EN 71-9 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, drewno i plyty drewno- pochodne, artykuly dla dzieci, wyroby do mocowania smoczka Emisja formaldehydu\nMetoda spektrofotometryczna PN-EN 717-3 | PN-EN 71-9 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde emission","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Formaldehyde emission Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 717-3 | PN-EN 71-9 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"甲醛释放量 分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 717-3 | PN-EN 71-9 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"分光光度法","methodology_zh":"甲醛释放量"},{"_id":"6a83b5ecaf14b9c0e7b20e7f","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, sztućce i naczynia do karmienia, materiały na zabawki i na artykuły dla dzieci, Wyroby polimerowe, tłoczywa melaminowo-formadehydowe przeznaczone do kontaktu z żywnością","methodology":"Zawartość ekstrahowalnego formaldehydu","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość ekstrahowalnego formaldehydu\nMetoda spektrofotometryczna","reference":"PN-EN ISO 4614 | PN-EN 71-9 | PN-EN 14372 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN ISO 4614","PN-EN 71-9","PN-EN 14372 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, sztućce i naczynia do karmienia, materiały na zabawki i na artykuły dla dzieci, Wyroby polimerowe, tłoczywa melaminowo-formadehydowe przeznaczone do kontaktu z żywnością Zawartość ekstrahowalnego formaldehydu\nMetoda spektrofotometryczna PN-EN ISO 4614 | PN-EN 71-9 | PN-EN 14372 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, artykuly dla dzieci, sztucce i naczynia do karmienia, materialy na zabawki i na artykuly dla dzieci, Wyroby polimerowe, tloczywa melaminowo-formadehydowe przeznaczone do kontaktu z zywnoscia Zawartosc ekstrahowalnego formaldehydu\nMetoda spektrofotometryczna PN-EN ISO 4614 | PN-EN 71-9 | PN-EN 14372 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials","food"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extractable formaldehyde content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Extractable formaldehyde content Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 4614 | PN-EN 71-9 | PN-EN 14372 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 4614 | PN-EN 71-9 | PN-EN 14372 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"分光光度法"},{"_id":"6a83b5ecaf14b9c0e7b20e80","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, wyroby do mocowania smoczka, smoczki do uspokajania niemowląt i małych dzieci, tworzywa sztuczne","methodology":"Migracja monomerów","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja monomerów\nMetoda spektrofotometryczna","reference":"PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1400 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 71-10","PN-EN 71-11","PN-EN 12586","PN-EN 1400 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, wyroby do mocowania smoczka, smoczki do uspokajania niemowląt i małych dzieci, tworzywa sztuczne Migracja monomerów\nMetoda spektrofotometryczna PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1400 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, artykuly dla dzieci, wyroby do mocowania smoczka, smoczki do uspokajania niemowlat i malych dzieci, tworzywa sztuczne Migracja monomerow\nMetoda spektrofotometryczna PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1400 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of monomers","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Migration of monomers Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1400 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 | PN-EN 1400 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"分光光度法"},{"_id":"6a83b5ecaf14b9c0e7b20e81","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Artykuły dla dzieci, sprzęt do picia, smoczki do uspokajania niemowląt i małych dzieci, materiały z gumy wulkanizowanej","methodology":"Migracja 2-merkaptobenzotiazolu (MBT), Migracja przeciwutleniaczy","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD)"],"computed":[],"activity":"Migracja 2-merkaptobenzotiazolu (MBT), Migracja przeciwutleniaczy\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD)","reference":"PN-EN 14350 | PN-EN 1400-3 | PN-EN 1400","norm_bases":["PN-EN 14350","PN-EN 1400-3","PN-EN 1400"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Artykuły dla dzieci, sprzęt do picia, smoczki do uspokajania niemowląt i małych dzieci, materiały z gumy wulkanizowanej Migracja 2-merkaptobenzotiazolu (MBT), Migracja przeciwutleniaczy\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD) PN-EN 14350 | PN-EN 1400-3 | PN-EN 1400 E, Artykuly dla dzieci, sprzet do picia, smoczki do uspokajania niemowlat i malych dzieci, materialy z gumy wulkanizowanej Migracja 2-merkaptobenzotiazolu (MBT), Migracja przeciwutleniaczy\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa i detekcja fluorescencyjna (HPLC-DAD-FLD) PN-EN 14350 | PN-EN 1400-3 | PN-EN 1400","categories":["materials"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of 2-mercaptobenzothiazole (MBT), Migration of antioxidants","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Migration of 2-mercaptobenzothiazole (MBT), Migration of antioxidants High-performance liquid chromatography with diode array detection and fluorescence detection (HPLC-DAD-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 14350 | PN-EN 1400-3 | PN-EN 1400","technique_en":"High-performance liquid chromatography with diode array detection and fluorescence detection (HPLC-DAD-FLD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 14350 | PN-EN 1400-3 | PN-EN 1400"},{"_id":"6a83b5ecaf14b9c0e7b20e82","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Artykuły dla dzieci, sprzęt do picia, sztućce i naczynia do karmienia, smoczki do uspokajania niemowląt i małych dzieci, Materiały z termoplastycznych tworzyw sztucznych","methodology":"Stężenie bisfenolu A (2,2-bis (4-hydroksyfenylo)propanu) w ekstrakcie wodnym z materiału obiektu","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie bisfenolu A (2,2-bis (4-hydroksyfenylo)propanu) w ekstrakcie wodnym z materiału obiektu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN 14372 | PN-EN 1400","norm_bases":["PN-EN 14372","PN-EN 1400"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Artykuły dla dzieci, sprzęt do picia, sztućce i naczynia do karmienia, smoczki do uspokajania niemowląt i małych dzieci, Materiały z termoplastycznych tworzyw sztucznych Stężenie bisfenolu A (2,2-bis (4-hydroksyfenylo)propanu) w ekstrakcie wodnym z materiału obiektu\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN 14372 | PN-EN 1400 E, Artykuly dla dzieci, sprzet do picia, sztucce i naczynia do karmienia, smoczki do uspokajania niemowlat i malych dzieci, Materialy z termoplastycznych tworzyw sztucznych Stezenie bisfenolu A (2,2-bis (4-hydroksyfenylo)propanu) w ekstrakcie wodnym z materialu obiektu\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN 14372 | PN-EN 1400","categories":["materials"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bisphenol A (2,2-bis (4-hydroxyphenyl)propane) concentration in the aqueous extract from the material of the object","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Bisphenol A (2,2-bis (4-hydroxyphenyl)propane) concentration in the aqueous extract from the material of the object High-performance liquid chromatography with fluorescence detection (HPLC-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 14372 | PN-EN 1400","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 14372 | PN-EN 1400","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a83b5ecaf14b9c0e7b20e83","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Artykuły dla dzieci, smoczki do uspokajania niemowląt i małych dzieci, sztućce i naczynia do karmienia oraz sprzęt do picia, Wyroby z gumy silikonowej","methodology":"Zawartość związków lotnych","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość związków lotnych\nMetoda wagowa","reference":"PN-EN 14372 | PN-EN 1400 | PN-EN 14350","norm_bases":["PN-EN 14372","PN-EN 1400","PN-EN 14350"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Artykuły dla dzieci, smoczki do uspokajania niemowląt i małych dzieci, sztućce i naczynia do karmienia oraz sprzęt do picia, Wyroby z gumy silikonowej Zawartość związków lotnych\nMetoda wagowa PN-EN 14372 | PN-EN 1400 | PN-EN 14350 E, Artykuly dla dzieci, smoczki do uspokajania niemowlat i malych dzieci, sztucce i naczynia do karmienia oraz sprzet do picia, Wyroby z gumy silikonowej Zawartosc zwiazkow lotnych\nMetoda wagowa PN-EN 14372 | PN-EN 1400 | PN-EN 14350","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile compound content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Volatile compound content Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 14372 | PN-EN 1400 | PN-EN 14350","technique_en":"Gravimetric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 14372 | PN-EN 1400 | PN-EN 14350","technique_zh":"重量法"},{"_id":"6a83b5ecaf14b9c0e7b20e84","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Powłoki antykorozyjne wyrobów i elementów metalowych sprzętu elektrycznego i elektronicznego, Zabawki i artykułu dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Obecność Cr (VI)","parameters":[],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Badania bezpieczeństwa, Obecność Cr (VI)\nMetoda kolorymetryczna","reference":"* | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-7-1 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym","norm_bases":["*","PN-EN 62321","PN-EN 62321-1","PN-EN 62321-7-1 Dyrektywa 2011/65/UE – RoHS","Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Powłoki antykorozyjne wyrobów i elementów metalowych sprzętu elektrycznego i elektronicznego, Zabawki i artykułu dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Obecność Cr (VI)\nMetoda kolorymetryczna * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-7-1 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym E, Powloki antykorozyjne wyrobow i elementow metalowych sprzetu elektrycznego i elektronicznego, Zabawki i artykulu dla dzieci, materialy na zabawki i artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Obecnosc Cr (VI)\nMetoda kolorymetryczna * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-7-1 Dyrektywa 2011/65/UE – RoHS | Rozporzadzenie Ministra Rozwoju i Finansow z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagan dotyczacych ograniczenia stosowania niektorych niebezpiecznych substancji w sprzecie elektrycznym i elektronicznym","categories":["materials","petro","electronics"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Presence of Cr (VI)","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Presence of Cr (VI) Colorimetric method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-7-1 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym","technique_en":"Colorimetric method","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"比色法 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-7-1 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym","technique_zh":"比色法"},{"_id":"6a83b5ecaf14b9c0e7b20e85","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością","methodology":"Migracja specyficzna formaldehydu","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja specyficzna formaldehydu\nMetoda spektrofotometryczna","reference":"PN-EN 13130-1 Rozporządzenia Komisji (UE): nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością nr 284/2011 ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-23","norm_bases":["PN-EN 13130-1 Rozporządzenia Komisji (UE): nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością nr 284/2011 ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong","PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-23"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością Migracja specyficzna formaldehydu\nMetoda spektrofotometryczna PN-EN 13130-1 Rozporządzenia Komisji (UE): nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością nr 284/2011 ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-23 E, Materialy i wyroby przeznaczone do kontaktu z zywnoscia Migracja specyficzna formaldehydu\nMetoda spektrofotometryczna PN-EN 13130-1 Rozporzadzenia Komisji (UE): nr 10/2011 w sprawie materialow i wyrobow z tworzyw sztucznych przeznaczonych do kontaktu z zywnoscia nr 284/2011 ustanawiajace specjalne warunki i szczegolowe procedury dotyczace przywozu przyborow kuchennych z tworzyw poliamidowych i melaminowych pochodzacych lub wyslanych z Chinskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-23","categories":["materials","food"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specific migration of formaldehyde","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Specific migration of formaldehyde Spectrophotometric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 13130-1 Rozporządzenia Komisji (UE): nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością nr 284/2011 ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-23","technique_en":"Spectrophotometric method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"分光光度法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 13130-1 Rozporządzenia Komisji (UE): nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością nr 284/2011 ustanawiające specjalne warunki i szczegółowe procedury dotyczące przywozu przyborów kuchennych z tworzyw poliamidowych i melaminowych pochodzących lub wysłanych z Chińskiej Republiki Ludowej i Specjalnego Regionu Administracyjnego Hongkong | PB-DLS/26 Specyfikacja Techniczna CEN/TS 13130-23","technique_zh":"分光光度法"},{"_id":"6a83b5ecaf14b9c0e7b20e86","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby tekstylne i skórzane, środki suszące, papier, drewno, tworzywa sztuczne, płyny","methodology":"Badania bezpieczeństwa, Zawartość fumaranu dimetylu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość fumaranu dimetylu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DLS/22 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PB-DLS/22","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby tekstylne i skórzane, środki suszące, papier, drewno, tworzywa sztuczne, płyny Badania bezpieczeństwa, Zawartość fumaranu dimetylu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DLS/22 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby tekstylne i skorzane, srodki suszace, papier, drewno, tworzywa sztuczne, plyny Badania bezpieczenstwa, Zawartosc fumaranu dimetylu\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DLS/22 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["materials"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Dimethyl fumarate content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Dimethyl fumarate content Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/22 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/22 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e87","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby stalowe, żeliwne, metalowe","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"* | PB-DLS/02","norm_bases":["*","PB-DLS/02"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby stalowe, żeliwne, metalowe Zawartość pierwiastków\nMetoda wysokotemperaturowego spalania z detekcją IR * | PB-DLS/02 E, Wyroby stalowe, zeliwne, metalowe Zawartosc pierwiastkow\nMetoda wysokotemperaturowego spalania z detekcja IR * | PB-DLS/02","categories":["materials"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Element content High-temperature combustion with IR detection Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PB-DLS/02","technique_en":"High-temperature combustion with IR detection","methodology_zh":"元素含量","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"元素含量 高温燃烧红外检测法 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PB-DLS/02","technique_zh":"高温燃烧红外检测法"},{"_id":"6a83b5ecaf14b9c0e7b20e88","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby stalowe, żeliwne, metalowe","methodology":"Zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"* | PB-DLS/02","norm_bases":["*","PB-DLS/02"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby stalowe, żeliwne, metalowe Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) * | PB-DLS/02 E, Wyroby stalowe, zeliwne, metalowe Zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) * | PB-DLS/02","categories":["materials"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PB-DLS/02","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PB-DLS/02","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83b5ecaf14b9c0e7b20e89","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby metalowe, zabawki","methodology":"Badania bezpieczeństwa, Zawartość niklu","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość niklu\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"* | PB-DLS/02 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["*","PB-DLS/02 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby metalowe, zabawki Badania bezpieczeństwa, Zawartość niklu\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) * | PB-DLS/02 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Wyroby metalowe, zabawki Badania bezpieczenstwa, Zawartosc niklu\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) * | PB-DLS/02 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Nickel content","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Nickel content Inductively coupled plasma optical emission spectrometry (ICP-OES) Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PB-DLS/02 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PB-DLS/02 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83b5ecaf14b9c0e7b20e8a","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, huśtawki dla niemowląt, materiały na zabawki i na artykuły dla dzieci, Farby, wyroby tekstylne, materiały, które mogą mieć kontakt z dziećmi, odzież","methodology":"Badania bezpieczeństwa, Zawartość amin wolnych i uwalnianych z barwników azowych","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość amin wolnych i uwalnianych z barwników azowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"* | PN-EN 71-7 | PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN ISO 14362-1 | PN-EN ISO 14362-3 | PN-EN 12586 | PN-EN 13688 | PN-EN 16232 | PN-EN 12790-1 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["*","PN-EN 71-7","PN-EN 71-9","PN-EN 71-10","PN-EN 71-11","PN-EN ISO 14362-1","PN-EN ISO 14362-3","PN-EN 12586","PN-EN 13688","PN-EN 16232","PN-EN 12790-1","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, huśtawki dla niemowląt, materiały na zabawki i na artykuły dla dzieci, Farby, wyroby tekstylne, materiały, które mogą mieć kontakt z dziećmi, odzież Badania bezpieczeństwa, Zawartość amin wolnych i uwalnianych z barwników azowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) * | PN-EN 71-7 | PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN ISO 14362-1 | PN-EN ISO 14362-3 | PN-EN 12586 | PN-EN 13688 | PN-EN 16232 | PN-EN 12790-1 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, artykuly dla dzieci, hustawki dla niemowlat, materialy na zabawki i na artykuly dla dzieci, Farby, wyroby tekstylne, materialy, ktore moga miec kontakt z dziecmi, odziez Badania bezpieczenstwa, Zawartosc amin wolnych i uwalnianych z barwnikow azowych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) * | PN-EN 71-7 | PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN ISO 14362-1 | PN-EN ISO 14362-3 | PN-EN 12586 | PN-EN 13688 | PN-EN 16232 | PN-EN 12790-1 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Content of free amines and amines released from azo dyes","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Content of free amines and amines released from azo dyes High-performance liquid chromatography with diode array detection (HPLC-DAD) Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 71-7 | PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN ISO 14362-1 | PN-EN ISO 14362-3 | PN-EN 12586 | PN-EN 13688 | PN-EN 16232 | PN-EN 12790-1 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD） 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 71-7 | PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN ISO 14362-1 | PN-EN ISO 14362-3 | PN-EN 12586 | PN-EN 13688 | PN-EN 16232 | PN-EN 12790-1 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a83b5ecaf14b9c0e7b20e8b","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby konsumenckie, materiały na wyroby konsumenckie, Nawierzchnie z tworzyw sztucznych, Sprzęt elektryczny i elektroniczny oraz jego elementy, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego, Wyroby medyczne i materiały na wyroby medyczne, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość ftalanów","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość ftalanów\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"* | PN-EN 14372 | PN-EN 12586 | ASTM F963 | PB-DLS/12 | Rozporządzenie (WE)nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2011/65/UE – RoHS Dyrektywa Delegowana Komisji (UE) 2015/863 Consumer Product Safety Improvement Act (CPSIA) | DIN 18035-6 | DIN 18035-7","norm_bases":["*","PN-EN 14372","PN-EN 12586","ASTM F963","PB-DLS/12","Rozporządzenie (WE)nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2011/65/UE – RoHS Dyrektywa Delegowana Komisji (UE) 2015/863 Consumer Product Safety Improvement Act (CPSIA)","DIN 18035-6","DIN 18035-7"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby konsumenckie, materiały na wyroby konsumenckie, Nawierzchnie z tworzyw sztucznych, Sprzęt elektryczny i elektroniczny oraz jego elementy, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego, Wyroby medyczne i materiały na wyroby medyczne, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość ftalanów\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) * | PN-EN 14372 | PN-EN 12586 | ASTM F963 | PB-DLS/12 | Rozporządzenie (WE)nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2011/65/UE – RoHS Dyrektywa Delegowana Komisji (UE) 2015/863 Consumer Product Safety Improvement Act (CPSIA) | DIN 18035-6 | DIN 18035-7 E, Zabawki i artykuly dla dzieci, materialy na zabawki i na artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Wyroby konsumenckie, materialy na wyroby konsumenckie, Nawierzchnie z tworzyw sztucznych, Sprzet elektryczny i elektroniczny oraz jego elementy, materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego, Wyroby medyczne i materialy na wyroby medyczne, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc ftalanow\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) * | PN-EN 14372 | PN-EN 12586 | ASTM F963 | PB-DLS/12 | Rozporzadzenie (WE)nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2011/65/UE – RoHS Dyrektywa Delegowana Komisji (UE) 2015/863 Consumer Product Safety Improvement Act (CPSIA) | DIN 18035-6 | DIN 18035-7","categories":["materials","petro","electronics"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Phthalate content","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Phthalate content Gas chromatography with mass spectrometry detection (GC-MS) Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 14372 | PN-EN 12586 | ASTM F963 | PB-DLS/12 | Rozporządzenie (WE)nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2011/65/UE – RoHS Dyrektywa Delegowana Komisji (UE) 2015/863 Consumer Product Safety Improvement Act (CPSIA) | DIN 18035-6 | DIN 18035-7","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） 实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 14372 | PN-EN 12586 | ASTM F963 | PB-DLS/12 | Rozporządzenie (WE)nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2011/65/UE – RoHS Dyrektywa Delegowana Komisji (UE) 2015/863 Consumer Product Safety Improvement Act (CPSIA) | DIN 18035-6 | DIN 18035-7","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e8c","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością","methodology":"Migracja specyficzna pierwiastków","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Migracja specyficzna pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością Rezolucja w sprawie bezpieczeństwa i jakości materiałów i wyrobów przeznaczonych do kontaktu z żywnością Przewodnik Techniczny pt. „Metals and alloys used in food contact materials and articles – A practical guide for manufacturers and regulators” | PB-DLS/26","norm_bases":["PN-EN 13130-1","Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością Rezolucja w sprawie bezpieczeństwa i jakości materiałów i wyrobów przeznaczonych do kontaktu z żywnością Przewodnik Techniczny pt. „Metals and alloys used in food contact materials and articles – A practical guide for manufacturers and regulators”","PB-DLS/26"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Materiały i wyroby przeznaczone do kontaktu z żywnością Migracja specyficzna pierwiastków\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością Rezolucja w sprawie bezpieczeństwa i jakości materiałów i wyrobów przeznaczonych do kontaktu z żywnością Przewodnik Techniczny pt. „Metals and alloys used in food contact materials and articles – A practical guide for manufacturers and regulators” | PB-DLS/26 E, Materialy i wyroby przeznaczone do kontaktu z zywnoscia Migracja specyficzna pierwiastkow\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 13130-1 | Rozporzadzenie Komisji (UE) nr 10/2011 w sprawie materialow i wyrobow z tworzyw sztucznych przeznaczonych do kontaktu z zywnoscia Rezolucja w sprawie bezpieczenstwa i jakosci materialow i wyrobow przeznaczonych do kontaktu z zywnoscia Przewodnik Techniczny pt. „Metals and alloys used in food contact materials and articles – A practical guide for manufacturers and regulators” | PB-DLS/26","categories":["materials","food"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specific migration of elements","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Specific migration of elements Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością Rezolucja w sprawie bezpieczeństwa i jakości materiałów i wyrobów przeznaczonych do kontaktu z żywnością Przewodnik Techniczny pt. „Metals and alloys used in food contact materials and articles – A practical guide for manufacturers and regulators” | PB-DLS/26","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体质谱法（ICP-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 13130-1 | Rozporządzenie Komisji (UE) nr 10/2011 w sprawie materiałów i wyrobów z tworzyw sztucznych przeznaczonych do kontaktu z żywnością Rezolucja w sprawie bezpieczeństwa i jakości materiałów i wyrobów przeznaczonych do kontaktu z żywnością Przewodnik Techniczny pt. „Metals and alloys used in food contact materials and articles – A practical guide for manufacturers and regulators” | PB-DLS/26","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e8d","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, materiały na zabawki, Artykuły dla dzieci, wyroby do mocowania smoczka, Tworzywa sztuczne, gumy","methodology":"Badania bezpieczeństwa, Migracja i zawartość monomerów i konserwantów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) i wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) i wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD)"],"computed":[],"activity":"Badania bezpieczeństwa, Migracja i zawartość monomerów i konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) i wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD)","reference":"PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 71-9","PN-EN 71-10","PN-EN 71-11","PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, materiały na zabawki, Artykuły dla dzieci, wyroby do mocowania smoczka, Tworzywa sztuczne, gumy Badania bezpieczeństwa, Migracja i zawartość monomerów i konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) i wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową i detekcją fluorescencyjną (HPLC-DAD-FLD) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, materialy na zabawki, Artykuly dla dzieci, wyroby do mocowania smoczka, Tworzywa sztuczne, gumy Badania bezpieczenstwa, Migracja i zawartosc monomerow i konserwantow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) i wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa i detekcja fluorescencyjna (HPLC-DAD-FLD) PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Migration and content of monomers and preservatives","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Migration and content of monomers and preservatives High-performance liquid chromatography with diode array detection (HPLC-DAD) and high-performance liquid chromatography with diode array detection and fluorescence detection (HPLC-DAD-FLD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD) and high-performance liquid chromatography with diode array detection and fluorescence detection (HPLC-DAD-FLD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 71-9 | PN-EN 71-10 | PN-EN 71-11 | PN-EN 12586 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"},{"_id":"6a83b5ecaf14b9c0e7b20e8e","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki, artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi","methodology":"Badania bezpieczeństwa, Migracja pierwiastków i związków cynoorganicznych","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS); Metoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS); Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","Metoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS)","Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Migracja pierwiastków i związków cynoorganicznych\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS); Metoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS); Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"* | PN-EN 71-3 | PN-EN 71-7 | PN-EN 1400 | PN-EN 14350 | PN-EN 14372 | PN-EN 1930 | PN-EN 12586 | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 14988 | PN-EN 1273 | PN-EN 1888-1 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1466 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 13210-1 | PN-EN 13210-2 | PN-EN 14036 | PN-EN 14344 | PN-EN 1130 | PN-EN 716-1 | PN-EN 16232 | PN-EN ISO 8098 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 17022 | PN-EN 17072 | PN-EN 17191 PKN-CEN/TR 16512 | ASTM F963 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["*","PN-EN 71-3","PN-EN 71-7","PN-EN 1400","PN-EN 14350","PN-EN 14372","PN-EN 1930","PN-EN 12586","PN-EN 13209-1","PN-EN 13209-2","PN-EN 14988","PN-EN 1273","PN-EN 1888-1","PN-EN 12790","PN-EN 12790-1","PN-EN 1466","PN-EN 12221-1","PN-EN 12227","PN-EN 13210-1","PN-EN 13210-2","PN-EN 14036","PN-EN 14344","PN-EN 1130","PN-EN 716-1","PN-EN 16232","PN-EN ISO 8098","PN-EN 16890","PN-EN 16780","PN-EN 16781","PN-EN 16779-1","PN-EN 17022","PN-EN 17072","PN-EN 17191 PKN-CEN/TR 16512","ASTM F963 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki, artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi Badania bezpieczeństwa, Migracja pierwiastków i związków cynoorganicznych\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS); Metoda wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas z jonizacją w plazmie indukcyjnie sprzężonej (HPLC-ICP-MS); Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS); Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) * | PN-EN 71-3 | PN-EN 71-7 | PN-EN 1400 | PN-EN 14350 | PN-EN 14372 | PN-EN 1930 | PN-EN 12586 | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 14988 | PN-EN 1273 | PN-EN 1888-1 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1466 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 13210-1 | PN-EN 13210-2 | PN-EN 14036 | PN-EN 14344 | PN-EN 1130 | PN-EN 716-1 | PN-EN 16232 | PN-EN ISO 8098 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 17022 | PN-EN 17072 | PN-EN 17191 PKN-CEN/TR 16512 | ASTM F963 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki, artykuly dla dzieci, materialy na zabawki i na artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi Badania bezpieczenstwa, Migracja pierwiastkow i zwiazkow cynoorganicznych\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS); Metoda wysokosprawnej chromatografii cieczowej sprzezonej ze spektrometria mas z jonizacja w plazmie indukcyjnie sprzezonej (HPLC-ICP-MS); Metoda chromatografii gazowej z detekcja spektrometria mas (GC-MS); Metoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) * | PN-EN 71-3 | PN-EN 71-7 | PN-EN 1400 | PN-EN 14350 | PN-EN 14372 | PN-EN 1930 | PN-EN 12586 | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 14988 | PN-EN 1273 | PN-EN 1888-1 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1466 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 13210-1 | PN-EN 13210-2 | PN-EN 14036 | PN-EN 14344 | PN-EN 1130 | PN-EN 716-1 | PN-EN 16232 | PN-EN ISO 8098 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 17022 | PN-EN 17072 | PN-EN 17191 PKN-CEN/TR 16512 | ASTM F963 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Migration of elements and organotin compounds","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Migration of elements and organotin compounds Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 71-3 | PN-EN 71-7 | PN-EN 1400 | PN-EN 14350 | PN-EN 14372 | PN-EN 1930 | PN-EN 12586 | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 14988 | PN-EN 1273 | PN-EN 1888-1 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1466 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 13210-1 | PN-EN 13210-2 | PN-EN 14036 | PN-EN 14344 | PN-EN 1130 | PN-EN 716-1 | PN-EN 16232 | PN-EN ISO 8098 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 17022 | PN-EN 17072 | PN-EN 17191 PKN-CEN/TR 16512 | ASTM F963 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 71-3 | PN-EN 71-7 | PN-EN 1400 | PN-EN 14350 | PN-EN 14372 | PN-EN 1930 | PN-EN 12586 | PN-EN 13209-1 | PN-EN 13209-2 | PN-EN 14988 | PN-EN 1273 | PN-EN 1888-1 | PN-EN 12790 | PN-EN 12790-1 | PN-EN 1466 | PN-EN 12221-1 | PN-EN 12227 | PN-EN 13210-1 | PN-EN 13210-2 | PN-EN 14036 | PN-EN 14344 | PN-EN 1130 | PN-EN 716-1 | PN-EN 16232 | PN-EN ISO 8098 | PN-EN 16890 | PN-EN 16780 | PN-EN 16781 | PN-EN 16779-1 | PN-EN 17022 | PN-EN 17072 | PN-EN 17191 PKN-CEN/TR 16512 | ASTM F963 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"},{"_id":"6a83b5ecaf14b9c0e7b20e8f","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby i elementy metalowe, wyroby jubilerskie, biżuteria, Artykuły dla dzieci, Odzież","methodology":"Badania bezpieczeństwa, Ilość uwalnianego Ni","parameters":[],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Ilość uwalnianego Ni\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN 1811 | PN-EN 16128 | PN-EN 14372 | PN-EN 12586 | PN-EN 14344 | PN-EN 13688 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady REACH","norm_bases":["PN-EN 1811","PN-EN 16128","PN-EN 14372","PN-EN 12586","PN-EN 14344","PN-EN 13688","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby i elementy metalowe, wyroby jubilerskie, biżuteria, Artykuły dla dzieci, Odzież Badania bezpieczeństwa, Ilość uwalnianego Ni\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN 1811 | PN-EN 16128 | PN-EN 14372 | PN-EN 12586 | PN-EN 14344 | PN-EN 13688 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady REACH E, Wyroby i elementy metalowe, wyroby jubilerskie, bizuteria, Artykuly dla dzieci, Odziez Badania bezpieczenstwa, Ilosc uwalnianego Ni\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN 1811 | PN-EN 16128 | PN-EN 14372 | PN-EN 12586 | PN-EN 14344 | PN-EN 13688 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady REACH","categories":["materials"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Amount of released Ni","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Amount of released Ni Inductively coupled plasma mass spectrometry (ICP-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 1811 | PN-EN 16128 | PN-EN 14372 | PN-EN 12586 | PN-EN 14344 | PN-EN 13688 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady REACH","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体质谱法（ICP-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 1811 | PN-EN 16128 | PN-EN 14372 | PN-EN 12586 | PN-EN 14344 | PN-EN 13688 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady REACH","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e90","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, papierowe, metalowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego, Wyroby konsumenckie, Zabawki i artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby jubilerskie, biżuteria, Opakowania, materiały na opakowania, Tworzywa sztuczne, Papier, Drewno, Szkło, Metale, Wyroby z tworzyw sztucznych, Farby i powłoki, Wyroby metalowe, Skóra, wyroby skóropodobne, Materiały włókiennicze i tekstylne, Baterie i akumulatory, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość pierwiastków","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS); Metoda spektrofotometryczna","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","Metoda spektrofotometryczna"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS); Metoda spektrofotometryczna","reference":"* | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-4 | PN-EN 62321-5 | PN-EN 62321-7-2 | PB-DLS/29 | PB-DLS/14 | PB-DLS/40 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym Dyrektywa 94/62/WE w sprawie opakowań i odpadów opakowaniowych | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2006/66/WE Parlamentu Europejskiego i Rady Dyrektywa 2000/53/WE w sprawie pojazdów wycofanych z eksploatacji","norm_bases":["*","PN-EN 62321","PN-EN 62321-1","PN-EN 62321-4","PN-EN 62321-5","PN-EN 62321-7-2","PB-DLS/29","PB-DLS/14","PB-DLS/40 Dyrektywa 2011/65/UE – RoHS","Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym Dyrektywa 94/62/WE w sprawie opakowań i odpadów opakowaniowych","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2006/66/WE Parlamentu Europejskiego i Rady Dyrektywa 2000/53/WE w sprawie pojazdów wycofanych z eksploatacji"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Sprzęt elektryczny i elektroniczny oraz jego elementy polimerowe, papierowe, metalowe i elektroniczne, materiały stosowane do produkcji sprzętu elektrycznego i elektronicznego, Wyroby konsumenckie, Zabawki i artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby jubilerskie, biżuteria, Opakowania, materiały na opakowania, Tworzywa sztuczne, Papier, Drewno, Szkło, Metale, Wyroby z tworzyw sztucznych, Farby i powłoki, Wyroby metalowe, Skóra, wyroby skóropodobne, Materiały włókiennicze i tekstylne, Baterie i akumulatory, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość pierwiastków\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES); Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS); Metoda spektrofotometryczna * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-4 | PN-EN 62321-5 | PN-EN 62321-7-2 | PB-DLS/29 | PB-DLS/14 | PB-DLS/40 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym Dyrektywa 94/62/WE w sprawie opakowań i odpadów opakowaniowych | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2006/66/WE Parlamentu Europejskiego i Rady Dyrektywa 2000/53/WE w sprawie pojazdów wycofanych z eksploatacji E, Sprzet elektryczny i elektroniczny oraz jego elementy polimerowe, papierowe, metalowe i elektroniczne, materialy stosowane do produkcji sprzetu elektrycznego i elektronicznego, Wyroby konsumenckie, Zabawki i artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Wyroby jubilerskie, bizuteria, Opakowania, materialy na opakowania, Tworzywa sztuczne, Papier, Drewno, Szklo, Metale, Wyroby z tworzyw sztucznych, Farby i powloki, Wyroby metalowe, Skora, wyroby skoropodobne, Materialy wlokiennicze i tekstylne, Baterie i akumulatory, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc pierwiastkow\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES); Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS); Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rteci (CVAAS); Metoda spektrofotometryczna * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-4 | PN-EN 62321-5 | PN-EN 62321-7-2 | PB-DLS/29 | PB-DLS/14 | PB-DLS/40 Dyrektywa 2011/65/UE – RoHS | Rozporzadzenie Ministra Rozwoju i Finansow z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagan dotyczacych ograniczenia stosowania niektorych niebezpiecznych substancji w sprzecie elektrycznym i elektronicznym Dyrektywa 94/62/WE w sprawie opakowan i odpadow opakowaniowych | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2006/66/WE Parlamentu Europejskiego i Rady Dyrektywa 2000/53/WE w sprawie pojazdow wycofanych z eksploatacji","categories":["materials","environment","petro","automotive","electronics"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety tests, Element content","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety tests, Element content Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma mass spectrometry (ICP-MS); Atomic absorption spectrometry with cold vapour mercury generation (CVAAS); Spectrophotometric method Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-4 | PN-EN 62321-5 | PN-EN 62321-7-2 | PB-DLS/29 | PB-DLS/14 | PB-DLS/40 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym Dyrektywa 94/62/WE w sprawie opakowań i odpadów opakowaniowych | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2006/66/WE Parlamentu Europejskiego i Rady Dyrektywa 2000/53/WE w sprawie pojazdów wycofanych z eksploatacji","technique_en":"Inductively coupled plasma atomic emission spectrometry (ICP-OES); Inductively coupled plasma mass spectrometry (ICP-MS); Atomic absorption spectrometry with cold vapour mercury generation (CVAAS); Spectrophotometric method","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN 62321 | PN-EN 62321-1 | PN-EN 62321-4 | PN-EN 62321-5 | PN-EN 62321-7-2 | PB-DLS/29 | PB-DLS/14 | PB-DLS/40 Dyrektywa 2011/65/UE – RoHS | Rozporządzenie Ministra Rozwoju i Finansów z dnia 21 grudnia 2016 r. w sprawie zasadniczych wymagań dotyczących ograniczenia stosowania niektórych niebezpiecznych substancji w sprzęcie elektrycznym i elektronicznym Dyrektywa 94/62/WE w sprawie opakowań i odpadów opakowaniowych | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH Dyrektywa 2006/66/WE Parlamentu Europejskiego i Rady Dyrektywa 2000/53/WE w sprawie pojazdów wycofanych z eksploatacji"},{"_id":"6a83b5ecaf14b9c0e7b20e91","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Materiały wykorzystywane do produkcji wyrobów konsumenckich, w tym artykułów dla dzieci, Tworzywa sztuczne, tekstylia, farby, lakiery","methodology":"Odporność na promieniowanie świetlne i działania atmosferyczne","parameters":[],"technique":"Metoda ekspozycji, badanie stopnia zmiany barwy","techniques":["Metoda ekspozycji, badanie stopnia zmiany barwy"],"computed":[],"activity":"Odporność na promieniowanie świetlne i działania atmosferyczne\nMetoda ekspozycji, badanie stopnia zmiany barwy","reference":"* | PN-EN ISO 4892-1 | PN-EN ISO 4892-2 | PN-EN ISO 105-B02 | PN-EN ISO 105-B04 | PN-EN ISO 105-B06 | PN-EN ISO 16474-1 | PN-EN ISO 16474-2 | PN-EN 607 | PN-EN 513","norm_bases":["*","PN-EN ISO 4892-1","PN-EN ISO 4892-2","PN-EN ISO 105-B02","PN-EN ISO 105-B04","PN-EN ISO 105-B06","PN-EN ISO 16474-1","PN-EN ISO 16474-2","PN-EN 607","PN-EN 513"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"Badania, na podstawie wyników których laboratorium formułuje opinie i interpretacje oznaczone zostały symbolem *\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Materiały wykorzystywane do produkcji wyrobów konsumenckich, w tym artykułów dla dzieci, Tworzywa sztuczne, tekstylia, farby, lakiery Odporność na promieniowanie świetlne i działania atmosferyczne\nMetoda ekspozycji, badanie stopnia zmiany barwy * | PN-EN ISO 4892-1 | PN-EN ISO 4892-2 | PN-EN ISO 105-B02 | PN-EN ISO 105-B04 | PN-EN ISO 105-B06 | PN-EN ISO 16474-1 | PN-EN ISO 16474-2 | PN-EN 607 | PN-EN 513 E, Materialy wykorzystywane do produkcji wyrobow konsumenckich, w tym artykulow dla dzieci, Tworzywa sztuczne, tekstylia, farby, lakiery Odpornosc na promieniowanie swietlne i dzialania atmosferyczne\nMetoda ekspozycji, badanie stopnia zmiany barwy * | PN-EN ISO 4892-1 | PN-EN ISO 4892-2 | PN-EN ISO 105-B02 | PN-EN ISO 105-B04 | PN-EN ISO 105-B06 | PN-EN ISO 16474-1 | PN-EN ISO 16474-2 | PN-EN 607 | PN-EN 513","categories":["materials","automotive"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to light radiation and weathering","regulatory_area_en":"Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Resistance to light radiation and weathering Exposure method, assessment of the degree of colour change Tests based on the results of which the laboratory formulates opinions and interpretations are marked with the * symbol\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. * | PN-EN ISO 4892-1 | PN-EN ISO 4892-2 | PN-EN ISO 105-B02 | PN-EN ISO 105-B04 | PN-EN ISO 105-B06 | PN-EN ISO 16474-1 | PN-EN ISO 16474-2 | PN-EN 607 | PN-EN 513","technique_en":"Exposure method, assessment of the degree of colour change","regulatory_area_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"实验室据以出具意见和解释的检测项目以 * 号标出\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 * | PN-EN ISO 4892-1 | PN-EN ISO 4892-2 | PN-EN ISO 105-B02 | PN-EN ISO 105-B04 | PN-EN ISO 105-B06 | PN-EN ISO 16474-1 | PN-EN ISO 16474-2 | PN-EN 607 | PN-EN 513"},{"_id":"6a83b5ecaf14b9c0e7b20e92","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby i materiały z tworzyw sztucznych, papieru i tekstylne","methodology":"Badania bezpieczeństwa, Zawartość uniepalniaczy","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość uniepalniaczy\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PB-DLS/12 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","norm_bases":["PN-EN 16781","PN-EN 16779-1","PN-EN 16780","PB-DLS/12 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby i materiały z tworzyw sztucznych, papieru i tekstylne Badania bezpieczeństwa, Zawartość uniepalniaczy\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PB-DLS/12 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek E, Zabawki i artykuly dla dzieci, materialy na zabawki i na artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Wyroby i materialy z tworzyw sztucznych, papieru i tekstylne Badania bezpieczenstwa, Zawartosc uniepalniaczy\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PB-DLS/12 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczenstwa zabawek","categories":["materials"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Flame retardant content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Flame retardant content Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PB-DLS/12 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN 16781 | PN-EN 16779-1 | PN-EN 16780 | PB-DLS/12 Dyrektywa Parlamentu Europejskiego i Rady 2009/48/WE w sprawie bezpieczeństwa zabawek","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e93","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, farby do malowania palcami, Wyroby i materiały z tworzyw sztucznych i gumy, farby, tkaniny, drewno, papier, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość wielopierścieniowych węglowodorów aromatycznych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość wielopierścieniowych węglowodorów aromatycznych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PB-DLS/38 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH AfPS GS PAK","norm_bases":["PB-DLS/38","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH AfPS GS PAK"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, farby do malowania palcami, Wyroby i materiały z tworzyw sztucznych i gumy, farby, tkaniny, drewno, papier, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość wielopierścieniowych węglowodorów aromatycznych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PB-DLS/38 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH AfPS GS PAK E, Zabawki i artykuly dla dzieci, materialy na zabawki i na artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, farby do malowania palcami, Wyroby i materialy z tworzyw sztucznych i gumy, farby, tkaniny, drewno, papier, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc wielopierscieniowych weglowodorow aromatycznych\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PB-DLS/38 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH AfPS GS PAK","categories":["materials","petro"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Polycyclic aromatic hydrocarbon content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Polycyclic aromatic hydrocarbon content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/38 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH AfPS GS PAK","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-串联质谱法（GC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/38 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH AfPS GS PAK","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e94","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby i materiały z tworzyw sztucznych i tekstylne, farby, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość benzenu","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość benzenu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"PB-DLS/12 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PB-DLS/12","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Zabawki i artykuły dla dzieci, materiały na zabawki i na artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby i materiały z tworzyw sztucznych i tekstylne, farby, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość benzenu\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) PB-DLS/12 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Zabawki i artykuly dla dzieci, materialy na zabawki i na artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Wyroby i materialy z tworzyw sztucznych i tekstylne, farby, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc benzenu\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) PB-DLS/12 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["materials","petro"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Benzene content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Benzene content Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/12 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/12 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e95","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby z tworzyw sztucznych, gumy, skóry, tkanin i papieru, Nawierzchnie z tworzyw sztucznych, Wyroby tytoniowe, Materiały smarne","methodology":"Badania bezpieczeństwa, Zawartość parafin chlorowanych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość parafin chlorowanych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS)","reference":"PB-DLS/42 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs | DIN 18035-6 | DIN 18035-7","norm_bases":["PB-DLS/42","Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","DIN 18035-6","DIN 18035-7"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby z tworzyw sztucznych, gumy, skóry, tkanin i papieru, Nawierzchnie z tworzyw sztucznych, Wyroby tytoniowe, Materiały smarne Badania bezpieczeństwa, Zawartość parafin chlorowanych\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS-MS) PB-DLS/42 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs | DIN 18035-6 | DIN 18035-7 E, Wyroby z tworzyw sztucznych, gumy, skory, tkanin i papieru, Nawierzchnie z tworzyw sztucznych, Wyroby tytoniowe, Materialy smarne Badania bezpieczenstwa, Zawartosc parafin chlorowanych\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS-MS) PB-DLS/42 | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs | DIN 18035-6 | DIN 18035-7","categories":["materials","petro"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Chlorinated paraffin content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Chlorinated paraffin content Gas chromatography with tandem mass spectrometry detection (GC-MS-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/42 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs | DIN 18035-6 | DIN 18035-7","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS-MS)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-串联质谱法（GC-MS-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/42 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs | DIN 18035-6 | DIN 18035-7","technique_zh":"气相色谱-串联质谱法（GC-MS-MS）"},{"_id":"6a83b5ecaf14b9c0e7b20e96","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Materiały i wyroby z papieru, tektury i masy włóknistej, Wyroby włókiennicze, skóra i wyroby skórzane, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Drewno, wyroby drewniane i drewnopochodne","methodology":"Badania bezpieczeństwa, Zawartość pentachlorofenolu (PCP)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość pentachlorofenolu (PCP)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN ISO 15320 | PN-EN 71-9 | PB-DLS/45 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","norm_bases":["PN-EN ISO 15320","PN-EN 71-9","PB-DLS/45","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Materiały i wyroby z papieru, tektury i masy włóknistej, Wyroby włókiennicze, skóra i wyroby skórzane, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Drewno, wyroby drewniane i drewnopochodne Badania bezpieczeństwa, Zawartość pentachlorofenolu (PCP)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-EN ISO 15320 | PN-EN 71-9 | PB-DLS/45 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs E, Materialy i wyroby z papieru, tektury i masy wloknistej, Wyroby wlokiennicze, skora i wyroby skorzane, Zabawki, artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Drewno, wyroby drewniane i drewnopochodne Badania bezpieczenstwa, Zawartosc pentachlorofenolu (PCP)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-EN ISO 15320 | PN-EN 71-9 | PB-DLS/45 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporzadzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","categories":["materials"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety testing, Pentachlorophenol (PCP) content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety testing, Pentachlorophenol (PCP) content High-performance liquid chromatography with diode array detection (HPLC-DAD) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 15320 | PN-EN 71-9 | PB-DLS/45 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 15320 | PN-EN 71-9 | PB-DLS/45 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH | Rozporządzenie Parlamentu Europejskiego i Rady (UE) 2019/1021 – POPs","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a83b5ecaf14b9c0e7b20e97","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Farby i powłoki z farb, tworzywa sztuczne, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci","methodology":"Badania bezpieczeństwa, Zawartość Pb","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość Pb\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"ASTM F963 | 1. US §16 C.F.R Part 1303 Ban of Lead-Containing Paint and Certain Consumer Products Bearing Lead Containing Paint: CPSC-CH-E1003-09.1, Procedure for Determining Lead (Pb) in Paint and Other Similar Surface Coating | 2. CPSC-CH-E1001-08.3, Procedure for Determining Total Lead (Pb) in Children’s Metal Products (Including Children’s Metal Jewelry) | 3. CPSC-CH-E1002-08.3, Procedure for Determining Total Lead (Pb) in Nonmetal Children’s Product | PB-DLS/29 | PB-DLS/40 Consumer Product Safety Improvement Act (CPSIA)","norm_bases":["ASTM F963","1. US §16 C.F.R Part 1303 Ban of Lead-Containing Paint and Certain Consumer Products Bearing Lead Containing Paint: CPSC-CH-E1003-09.1, Procedure for Determining Lead (Pb) in Paint and Other Similar Surface Coating","2. CPSC-CH-E1001-08.3, Procedure for Determining Total Lead (Pb) in Children’s Metal Products (Including Children’s Metal Jewelry)","3. CPSC-CH-E1002-08.3, Procedure for Determining Total Lead (Pb) in Nonmetal Children’s Product","PB-DLS/29","PB-DLS/40 Consumer Product Safety Improvement Act (CPSIA)"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Farby i powłoki z farb, tworzywa sztuczne, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci Badania bezpieczeństwa, Zawartość Pb\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) ASTM F963 | 1. US §16 C.F.R Part 1303 Ban of Lead-Containing Paint and Certain Consumer Products Bearing Lead Containing Paint: CPSC-CH-E1003-09.1, Procedure for Determining Lead (Pb) in Paint and Other Similar Surface Coating | 2. CPSC-CH-E1001-08.3, Procedure for Determining Total Lead (Pb) in Children’s Metal Products (Including Children’s Metal Jewelry) | 3. CPSC-CH-E1002-08.3, Procedure for Determining Total Lead (Pb) in Nonmetal Children’s Product | PB-DLS/29 | PB-DLS/40 Consumer Product Safety Improvement Act (CPSIA) E, Farby i powloki z farb, tworzywa sztuczne, Zabawki, artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci Badania bezpieczenstwa, Zawartosc Pb\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) ASTM F963 | 1. US §16 C.F.R Part 1303 Ban of Lead-Containing Paint and Certain Consumer Products Bearing Lead Containing Paint: CPSC-CH-E1003-09.1, Procedure for Determining Lead (Pb) in Paint and Other Similar Surface Coating | 2. CPSC-CH-E1001-08.3, Procedure for Determining Total Lead (Pb) in Children’s Metal Products (Including Children’s Metal Jewelry) | 3. CPSC-CH-E1002-08.3, Procedure for Determining Total Lead (Pb) in Nonmetal Children’s Product | PB-DLS/29 | PB-DLS/40 Consumer Product Safety Improvement Act (CPSIA)","categories":["materials"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety tests, Pb content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety tests, Pb content Inductively coupled plasma optical emission spectrometry (ICP-OES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. ASTM F963 | 1. US §16 C.F.R Part 1303 Ban of Lead-Containing Paint and Certain Consumer Products Bearing Lead Containing Paint: CPSC-CH-E1003-09.1, Procedure for Determining Lead (Pb) in Paint and Other Similar Surface Coating | 2. CPSC-CH-E1001-08.3, Procedure for Determining Total Lead (Pb) in Children’s Metal Products (Including Children’s Metal Jewelry) | 3. CPSC-CH-E1002-08.3, Procedure for Determining Total Lead (Pb) in Nonmetal Children’s Product | PB-DLS/29 | PB-DLS/40 Consumer Product Safety Improvement Act (CPSIA)","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 ASTM F963 | 1. US §16 C.F.R Part 1303 Ban of Lead-Containing Paint and Certain Consumer Products Bearing Lead Containing Paint: CPSC-CH-E1003-09.1, Procedure for Determining Lead (Pb) in Paint and Other Similar Surface Coating | 2. CPSC-CH-E1001-08.3, Procedure for Determining Total Lead (Pb) in Children’s Metal Products (Including Children’s Metal Jewelry) | 3. CPSC-CH-E1002-08.3, Procedure for Determining Total Lead (Pb) in Nonmetal Children’s Product | PB-DLS/29 | PB-DLS/40 Consumer Product Safety Improvement Act (CPSIA)","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83b5ecaf14b9c0e7b20e98","lab_id":"69ad52a3de79e566650fb494","country":"PL","accr_number":"AB 910","accr_body":"PCA","test_object":"E, Wyroby konsumenckie, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby jubilerskie, biżuteria","methodology":"Badania bezpieczeństwa, Zawartość Pb","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Badania bezpieczeństwa, Zawartość Pb\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-DLS/40 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","norm_bases":["PB-DLS/40","Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH"],"lab_section":"Laboratorium Inżynierii Materiałowej i Środowiska","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"E, Wyroby konsumenckie, Zabawki, artykuły dla dzieci, materiały na zabawki i artykuły dla dzieci, materiały, które mogą mieć kontakt z dziećmi, Wyroby jubilerskie, biżuteria Badania bezpieczeństwa, Zawartość Pb\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-DLS/40 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH E, Wyroby konsumenckie, Zabawki, artykuly dla dzieci, materialy na zabawki i artykuly dla dzieci, materialy, ktore moga miec kontakt z dziecmi, Wyroby jubilerskie, bizuteria Badania bezpieczenstwa, Zawartosc Pb\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-DLS/40 | Rozporzadzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","categories":["materials"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Safety tests, Pb content","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Safety tests, Pb content Inductively coupled plasma optical emission spectrometry (ICP-OES) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PB-DLS/40 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"电感耦合等离子体原子发射光谱法（ICP-OES） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PB-DLS/40 | Rozporządzenie (WE) nr 1907/2006 Parlamentu Europejskiego i Rady – REACH","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"}],"has_pdf":true}