{"lab":{"_id":"69ad52a3de79e566650fb48a","accr_number":"AB 904","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE TÜV RHEINLAND POLSKA, ul. Wolności 347, 41-800 Zabrze","categories":["materials","construction"],"city":"Zabrze","imported_at":"2026-03-08T10:42:43.265Z","methods_count":355,"name":"TÜV RHEINLAND POLSKA Sp. z o. o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_904.pdf"],"scope_summary":"","search_text":"tüv rheinland polska sp. z o. o. laboratorium badawcze tüv rheinland polska, ul. wolności 347, 41-800 zabrze other metrology materials petro food pharma electronics construction","status":"active","updated_at":"2026-03-08T14:51:47.857Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:47.857Z","location":{"type":"Point","coordinates":[18.7857,50.3249]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20904,podmiot.html","fields_of_testing":[{"codes":"J/5, J/6, J/8, J/10, J/11, J/13, J/14, J/17, J/21, J/25, J/27, J/50, J/51, J/53, J/54","pl":"Badania mechaniczne: wyroby budowlane, materiały budowlane, obiekty budowlane; wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne; wyroby i materiały konstrukcyjne - w tym metale i kompozyty; paliwa; meble, maszyny zakładów produkcyjnych, wyposażenie medyczne; wyroby inne; wyroby z tworzyw sztucznych i gumy; zabawki, sprzęt sportowy i rekreacyjny; drewno","en":"Mechanical tests of building products, building materials, building items, electrical, telecommunication and electronic products and equipment, construction products and materials – including metals and composite materials, fuels, lubricants, crude oil, other petroleum products, furniture, machinery and devices production plants, equipment, medical equipment, other products, plastic and rubber products, toys, sports and leisure equipment, wood"},{"codes":"N/5, N/6, N/8, N/10, N/11, N/13, N/14, N/17, N/21, N/25, N/27, N/50, N/51, N/53, N/54","pl":"Badania właściwości fizycznych: wyroby budowlane, materiały budowlane, obiekty budowlane; wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne; wyroby i materiały konstrukcyjne - w tym metale i kompozyty; paliwa; meble; maszyny zakładów produkcyjnych, wyposażenie; wyposażenie medyczne; wyroby inne; wyroby z tworzyw sztucznych i gumy; zabawki, sprzęt sportowy i rekreacyjny; drewno","en":"Tests of physical properties of building products, building materials, building items, electrical, telecommunication and electronic products and equipment, construction products and materials – including metals and composite materials, fuels, lubricants, crude oil, other petroleum products, furniture, machinery and devices production plants, equipment, medical equipment, other products, plastic and rubber products, toys, sports and leisure equipment, wood"},{"codes":"L/8","pl":"Badania nieniszczące: wyroby i materiały konstrukcyjne w tym metale i kompozyty","en":"Non-destructive tests of construction products and materials – including metals and composite materials"}],"issue":{"no":"24","date":"10.09.2025"},"parse_date":"2026-07-20T19:34:29.060Z","parse_source":"script-pdfplumber","map_coord":[50.298459,18.797558],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":314,"materials":20,"construction":13,"petro":4,"water":4},"category_scores":{"other":277.74,"materials":1.13,"construction":0.48,"petro":0.05,"water":0.05},"has_zh":true},"methods":[{"_id":"6a5e78454cc76d93cba3b345","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wysokie krzesełka dla dzieci E","test_object_en":"High chairs for children E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 14988","norm_bases":["PN-EN 14988"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokie krzesełka dla dzieci E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 14988 Wysokie krzeselka dla dzieci E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 14988","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High chairs for children E Stability Method: loading with force and/or mass Range Range PN-EN 14988","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 14988","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b346","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wysokie krzesełka dla dzieci E","test_object_en":"High chairs for children E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","reference":"PN-EN 14988","norm_bases":["PN-EN 14988"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokie krzesełka dla dzieci E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia PN-EN 14988 Wysokie krzeselka dla dzieci E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciazenie sila i/lub masa, proba cyklicznego uderzenia PN-EN 14988","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High chairs for children E Strength of construction Method: force and/or mass loading, cyclic impact test Range Range PN-EN 14988","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、循环冲击试验 范围 范围 PN-EN 14988","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、循环冲击试验"},{"_id":"6a5e78454cc76d93cba3b347","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wysokie krzesełka dla dzieci E","test_object_en":"High chairs for children E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 14988","norm_bases":["PN-EN 14988"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wysokie krzesełka dla dzieci E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 14988 Wysokie krzeselka dla dzieci E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 14988","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"High chairs for children E Geometric dimensions Method: direct measurement, probe testing Range PN-EN 14988","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 PN-EN 14988","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b348","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Stoły robocze i biurka E","test_object_en":"Work tables and desks E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 527-1 | PN-EN 527-2","norm_bases":["PN-EN 527-1","PN-EN 527-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stoły robocze i biurka E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 527-1 | PN-EN 527-2 Stoly robocze i biurka E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 527-1 | PN-EN 527-2","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Work tables and desks E Stability Method: loading with force and/or mass Range Range PN-EN 527-1 | PN-EN 527-2","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 527-1 | PN-EN 527-2","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b349","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Stoły robocze i biurka E","test_object_en":"Work tables and desks E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","reference":"PN-EN 527-1 | PN-EN 527-2","norm_bases":["PN-EN 527-1","PN-EN 527-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stoły robocze i biurka E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia PN-EN 527-1 | PN-EN 527-2 Stoly robocze i biurka E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciazenie sila i/lub masa, proba cyklicznego uderzenia PN-EN 527-1 | PN-EN 527-2","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Work tables and desks E Strength of construction Method: force and/or mass loading, cyclic impact test Range Range PN-EN 527-1 | PN-EN 527-2","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、循环冲击试验 范围 范围 PN-EN 527-1 | PN-EN 527-2","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、循环冲击试验"},{"_id":"6a5e78454cc76d93cba3b34a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Stoły robocze i biurka E","test_object_en":"Work tables and desks E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN 527-1 | PN-EN 527-2","norm_bases":["PN-EN 527-1","PN-EN 527-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stoły robocze i biurka E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni PN-EN 527-1 | PN-EN 527-2 Stoly robocze i biurka E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni PN-EN 527-1 | PN-EN 527-2","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Work tables and desks E Geometric dimensions Method: direct measurement Range PN-EN 527-1 | PN-EN 527-2","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量 范围 PN-EN 527-1 | PN-EN 527-2","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b34b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania E","test_object_en":"Storage furniture E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 16121","norm_bases":["PN-EN 16121"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 16121 Meble do przechowywania E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 16121","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Storage furniture E Stability Method: loading with force and/or mass Range Range PN-EN 16121","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 16121","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b34c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania E","test_object_en":"Storage furniture E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(1 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(1 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (1 - 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN 16121","norm_bases":["PN-EN 16121"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania E Wymiary geometryczne\nZakres (1 - 5000) mm\nMetoda: pomiar bezpośredni PN-EN 16121 Meble do przechowywania E Wymiary geometryczne\nZakres (1 - 5000) mm\nMetoda: pomiar bezposredni PN-EN 16121","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Storage furniture E Geometric dimensions Method: direct measurement Range PN-EN 16121","parameters_zh":[{"name":"范围","range":"(1 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量 范围 PN-EN 16121","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b34d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania E","test_object_en":"Storage furniture E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","reference":"PN-EN 16121","norm_bases":["PN-EN 16121"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia PN-EN 16121 Meble do przechowywania E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg\nMetoda: obciazenie sila i/lub masa, proba cyklicznego uderzenia PN-EN 16121","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Storage furniture E Strength of construction Method: force and/or mass loading, cyclic impact test Range Range PN-EN 16121","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、循环冲击试验 范围 范围 PN-EN 16121","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、循环冲击试验"},{"_id":"6a5e78454cc76d93cba3b34e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Nawierzchnie amortyzujące upadki E","test_object_en":"Impact attenuating surfacing E","methodology":"Krytyczna wysokość upadku HIC","methodology_en":"Critical fall height HIC","parameters":[{"name":"Zakres","range":"(0 - 4000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4000) mm"}],"technique":"Metoda: badanie modelem głowy","techniques":["Metoda: badanie modelem głowy"],"technique_en":"Method: headform test","computed":[],"computed_en":[],"activity":"Krytyczna wysokość upadku HIC\nZakres (0 - 4000) mm\nMetoda: badanie modelem głowy","reference":"PN-EN 1177","norm_bases":["PN-EN 1177"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Nawierzchnie amortyzujące upadki E Krytyczna wysokość upadku HIC\nZakres (0 - 4000) mm\nMetoda: badanie modelem głowy PN-EN 1177 Nawierzchnie amortyzujace upadki E Krytyczna wysokosc upadku HIC\nZakres (0 - 4000) mm\nMetoda: badanie modelem glowy PN-EN 1177","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Impact attenuating surfacing E Critical fall height HIC Method: headform test Range PN-EN 1177","parameters_zh":[{"name":"范围","range":"(0 - 4000) mm"}],"search_zh":"方法：头部模型试验 范围 PN-EN 1177","technique_zh":"方法：头部模型试验"},{"_id":"6a5e78454cc76d93cba3b34f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw − huśtawki E","test_object_en":"Playground equipment − swings E","methodology":"Amortyzacja uderzeń siedzisk huśtawki","methodology_en":"Impact attenuation of swing seats","parameters":[{"name":"Zakres","range":"(0 - 200) g;"},{"name":"Zakres","range":"(0 - 1000) N/cm2"}],"parameters_en":[{"name":"Range","range":"(0 - 200) g;"},{"name":"Range","range":"(0 - 1000) N/cm2"}],"technique":"Metoda: badanie modelem głowy","techniques":["Metoda: badanie modelem głowy"],"technique_en":"Method: headform test","computed":[],"computed_en":[],"activity":"Amortyzacja uderzeń siedzisk huśtawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem głowy","reference":"P N - E N 1 1 7 6 - 2","norm_bases":["P N - E N 1 1 7 6 - 2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw − huśtawki E Amortyzacja uderzeń siedzisk huśtawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem głowy P N - E N 1 1 7 6 - 2 Wyposazenie placow zabaw − hustawki E Amortyzacja uderzen siedzisk hustawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem glowy P N - E N 1 1 7 6 - 2","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment − swings E Impact attenuation of swing seats Method: headform test Range Range P N - E N 1 1 7 6 - 2","parameters_zh":[{"name":"范围","range":"(0 - 200) g;"},{"name":"范围","range":"(0 - 1000) N/cm2"}],"search_zh":"方法：头部模型试验 范围 范围 P N - E N 1 1 7 6 - 2","technique_zh":"方法：头部模型试验"},{"_id":"6a5e78454cc76d93cba3b350","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw − huśtawki E","test_object_en":"Playground equipment − swings E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 1500) kg;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 1500) kg;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem"],"technique_en":"Method: force and/or mass loading, probe test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 360) °\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem","reference":"P N - E N 1 1 7 6 - 2","norm_bases":["P N - E N 1 1 7 6 - 2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw − huśtawki E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 360) °\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem P N - E N 1 1 7 6 - 2 Wyposazenie placow zabaw − hustawki E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 360) °\nMetoda: obciazenie sila i/lub masa, badanie probnikiem P N - E N 1 1 7 6 - 2","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment − swings E Strength of construction Method: force and/or mass loading, probe test Range Range Range P N - E N 1 1 7 6 - 2","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 1500) kg;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、探棒试验 范围 范围 范围 P N - E N 1 1 7 6 - 2","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、探棒试验"},{"_id":"6a5e78454cc76d93cba3b351","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw − huśtawki E","test_object_en":"Playground equipment − swings E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 20000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 20000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"P N - E N 1 1 7 6 - 2","norm_bases":["P N - E N 1 1 7 6 - 2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw − huśtawki E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni P N - E N 1 1 7 6 - 2 Wyposazenie placow zabaw − hustawki E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni P N - E N 1 1 7 6 - 2","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment − swings E Geometric dimensions Method: direct measurement Range Range P N - E N 1 1 7 6 - 2","parameters_zh":[{"name":"范围","range":"(0 - 20000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 P N - E N 1 1 7 6 - 2","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b352","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Drabiny E","test_object_en":"Ladders E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 270) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 270) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","norm_bases":["PN-EN 131-1","PN-EN 131-2","PN-EN 131-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drabiny E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezpośredni PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3 Drabiny E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezposredni PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ladders E Geometric dimensions Method: direct measurement Range Range PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 270) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b353","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Drabiny E","test_object_en":"Ladders E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"ugięcie,"},{"name":"skręcanie,"},{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 200) Nm;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 20000) mm"}],"parameters_en":[{"name":"deflection,"},{"name":"torsion,"},{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 200) Nm;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 20000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, próba stanowiskowa"],"technique_en":"Method: force and/or mass loading, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nugięcie,\nskręcanie,\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 200) Nm;\nZakres (0 - 360) °;\nZakres (0 - 20000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa","reference":"PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","norm_bases":["PN-EN 131-1","PN-EN 131-2","PN-EN 131-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drabiny E Wytrzymałość konstrukcji\nZakres:\nugięcie,\nskręcanie,\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 200) Nm;\nZakres (0 - 360) °;\nZakres (0 - 20000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3 Drabiny E Wytrzymalosc konstrukcji\nZakres:\nugiecie,\nskrecanie,\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 200) Nm;\nZakres (0 - 360) °;\nZakres (0 - 20000) mm\nMetoda: obciazenie sila i/lub masa, proba stanowiskowa PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Ladders E Strength of construction Method: force and/or mass loading, bench test deflection, torsion, strength of the product and its components, durability Range Range Range Range Range PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","parameters_zh":[{"name":"ugięcie,"},{"name":"skręcanie,"},{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 200) Nm;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 20000) mm"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 范围 PN-EN 131-1 | PN-EN 131-2 | PN-EN 131-3","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b354","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – krzesła i stoły dla instytucji edukacyjnych E","test_object_en":"Furniture – chairs and tables for educational institutions E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 1729-1 | PN-EN 1729-2","norm_bases":["PN-EN 1729-1","PN-EN 1729-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – krzesła i stoły dla instytucji edukacyjnych E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 1729-1 | PN-EN 1729-2 Meble – krzesla i stoly dla instytucji edukacyjnych E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 1729-1 | PN-EN 1729-2","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – chairs and tables for educational institutions E Geometric dimensions Method: direct measurement Range Range PN-EN 1729-1 | PN-EN 1729-2","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 1729-1 | PN-EN 1729-2","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b355","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – krzesła i stoły dla instytucji edukacyjnych E","test_object_en":"Furniture – chairs and tables for educational institutions E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 1729-1 | PN-EN 1729-2","norm_bases":["PN-EN 1729-1","PN-EN 1729-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – krzesła i stoły dla instytucji edukacyjnych E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 1729-1 | PN-EN 1729-2 Meble – krzesla i stoly dla instytucji edukacyjnych E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 1729-1 | PN-EN 1729-2","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – chairs and tables for educational institutions E Stability Method: loading with force and/or mass Range Range PN-EN 1729-1 | PN-EN 1729-2","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 1729-1 | PN-EN 1729-2","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b356","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – krzesła i stoły dla instytucji edukacyjnych E","test_object_en":"Furniture – chairs and tables for educational institutions E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1729-1 | PN-EN 1729-2","norm_bases":["PN-EN 1729-1","PN-EN 1729-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – krzesła i stoły dla instytucji edukacyjnych E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1729-1 | PN-EN 1729-2 Meble – krzesla i stoly dla instytucji edukacyjnych E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1729-1 | PN-EN 1729-2","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – chairs and tables for educational institutions E Strength of construction Method: loading with force and/or mass, probe testing, bench test Range Range Range PN-EN 1729-1 | PN-EN 1729-2","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 范围 范围 范围 PN-EN 1729-1 | PN-EN 1729-2","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b357","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – stoły robocze dla laboratoriów instytucji edukacyjnych E","test_object_en":"Furniture – workbenches for laboratories in educational institutions E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 1000) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 1000) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba uderzenia bijakiem","techniques":["Metoda: obciążenie siłą i/lub masą, próba uderzenia bijakiem"],"technique_en":"Method: loading with force and/or mass, impact test with a striker","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 1000) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą, próba uderzenia bijakiem","reference":"PN-EN 13150","norm_bases":["PN-EN 13150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – stoły robocze dla laboratoriów instytucji edukacyjnych E Stateczność\nZakres:\nZakres (0 - 1000) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą, próba uderzenia bijakiem PN-EN 13150 Meble – stoly robocze dla laboratoriow instytucji edukacyjnych E Statecznosc\nZakres:\nZakres (0 - 1000) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa, proba uderzenia bijakiem PN-EN 13150","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – workbenches for laboratories in educational institutions E Stability Method: loading with force and/or mass, impact test with a striker Range Range PN-EN 13150","parameters_zh":[{"name":"范围","range":"(0 - 1000) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 范围 范围 PN-EN 13150","methodology_zh":"稳定性"},{"_id":"6a5e78454cc76d93cba3b358","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – stoły robocze dla laboratoriów instytucji edukacyjnych E","test_object_en":"Furniture – workbenches for laboratories in educational institutions E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"ugięcie,"},{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"deflection,"},{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nugięcie,\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","reference":"PN-EN 13150","norm_bases":["PN-EN 13150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – stoły robocze dla laboratoriów instytucji edukacyjnych E Wytrzymałość konstrukcji\nZakres:\nugięcie,\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia PN-EN 13150 Meble – stoly robocze dla laboratoriow instytucji edukacyjnych E Wytrzymalosc konstrukcji\nZakres:\nugiecie,\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, proba cyklicznego uderzenia PN-EN 13150","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – workbenches for laboratories in educational institutions E Strength of construction Method: force and/or mass loading, cyclic impact test deflection, strength of the product and its components, durability Range Range Range PN-EN 13150","parameters_zh":[{"name":"ugięcie,"},{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、循环冲击试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 13150","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、循环冲击试验"},{"_id":"6a5e78454cc76d93cba3b359","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – stoły robocze dla laboratoriów instytucji edukacyjnych E","test_object_en":"Furniture – workbenches for laboratories in educational institutions E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm;\nMetoda: pomiar bezpośredni","reference":"PN-EN 13150","norm_bases":["PN-EN 13150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – stoły robocze dla laboratoriów instytucji edukacyjnych E Wymiary geometryczne\nZakres (0 - 5000) mm;\nMetoda: pomiar bezpośredni PN-EN 13150 Meble – stoly robocze dla laboratoriow instytucji edukacyjnych E Wymiary geometryczne\nZakres (0 - 5000) mm;\nMetoda: pomiar bezposredni PN-EN 13150","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – workbenches for laboratories in educational institutions E Geometric dimensions Method: direct measurement Range PN-EN 13150","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"}],"search_zh":"几何尺寸 方法：直接测量 范围 PN-EN 13150","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b35a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Domowe i kuchenne segmenty do przechowywania oraz blaty E","test_object_en":"Domestic and kitchen storage units and worktops E","methodology":"Masa wyrobu i jego elementów","methodology_en":"Mass of the product and its components","parameters":[{"name":"Zakres","range":"(0 - 150) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 150) kg"}],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"technique_en":"Method: gravimetric","computed":[],"computed_en":[],"activity":"Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa","reference":"PN-EN 14749","norm_bases":["PN-EN 14749"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domowe i kuchenne segmenty do przechowywania oraz blaty E Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 14749 Domowe i kuchenne segmenty do przechowywania oraz blaty E Masa wyrobu i jego elementow\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 14749","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Domestic and kitchen storage units and worktops E Mass of the product and its components Method: gravimetric Range PN-EN 14749","parameters_zh":[{"name":"范围","range":"(0 - 150) kg"}],"search_zh":"家用与厨房贮存单元及台面 E 制品及其部件的质量 方法：重量法 范围 PN-EN 14749","technique_zh":"方法：重量法","methodology_zh":"制品及其部件的质量","test_object_zh":"家用与厨房贮存单元及台面 E"},{"_id":"6a5e78454cc76d93cba3b35b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Domowe i kuchenne segmenty do przechowywania oraz blaty E","test_object_en":"Domestic and kitchen storage units and worktops E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN 14749","norm_bases":["PN-EN 14749"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domowe i kuchenne segmenty do przechowywania oraz blaty E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni PN-EN 14749 Domowe i kuchenne segmenty do przechowywania oraz blaty E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni PN-EN 14749","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Domestic and kitchen storage units and worktops E Geometric dimensions Method: direct measurement Range PN-EN 14749","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家用与厨房贮存单元及台面 E 几何尺寸 方法：直接测量 范围 PN-EN 14749","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量","test_object_zh":"家用与厨房贮存单元及台面 E"},{"_id":"6a5e78454cc76d93cba3b35c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Domowe i kuchenne segmenty do przechowywania oraz blaty E","test_object_en":"Domestic and kitchen storage units and worktops E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 200) Nm"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 200) Nm"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem"],"technique_en":"Method: force and/or mass and/or torque loading","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 200) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem","reference":"PN-EN 14749","norm_bases":["PN-EN 14749"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domowe i kuchenne segmenty do przechowywania oraz blaty E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 200) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem PN-EN 14749 Domowe i kuchenne segmenty do przechowywania oraz blaty E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 200) Nm\nMetoda: obciazenie sila i/lub masa i/lub momentem PN-EN 14749","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Domestic and kitchen storage units and worktops E Stability Method: force and/or mass and/or torque loading Range Range Range PN-EN 14749","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 200) Nm"}],"search_zh":"家用与厨房贮存单元及台面 E 稳定性 范围 范围 范围 PN-EN 14749","methodology_zh":"稳定性","test_object_zh":"家用与厨房贮存单元及台面 E"},{"_id":"6a5e78454cc76d93cba3b35d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Domowe i kuchenne segmenty do przechowywania oraz blaty E","test_object_en":"Domestic and kitchen storage units and worktops E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 14749","norm_bases":["PN-EN 14749"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Domowe i kuchenne segmenty do przechowywania oraz blaty E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 14749 Domowe i kuchenne segmenty do przechowywania oraz blaty E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 14749","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Domestic and kitchen storage units and worktops E Strength of construction Method: loading with force and/or mass, probe testing, bench test Range Range Range Range PN-EN 14749","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家用与厨房贮存单元及台面 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 范围 范围 范围 范围 PN-EN 14749","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"家用与厨房贮存单元及台面 E"},{"_id":"6a5e78454cc76d93cba3b35e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do użytkowania na zewnątrz – meble do siedzenia i stoły użytkowane na kempingu, na zewnątrz domu i w miejscach publicznych E","test_object_en":"Outdoor furniture – seating and tables for camping, domestic outdoor and public use E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","norm_bases":["PN-EN 581-1","PN-EN 581-2","PN-EN 581-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do użytkowania na zewnątrz – meble do siedzenia i stoły użytkowane na kempingu, na zewnątrz domu i w miejscach publicznych E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3 Meble do uzytkowania na zewnatrz – meble do siedzenia i stoly uzytkowane na kempingu, na zewnatrz domu i w miejscach publicznych E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Outdoor furniture – seating and tables for camping, domestic outdoor and public use E Stability Method: loading with force and/or mass Range Range PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b35f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do użytkowania na zewnątrz – meble do siedzenia i stoły użytkowane na kempingu, na zewnątrz domu i w miejscach publicznych E","test_object_en":"Outdoor furniture – seating and tables for camping, domestic outdoor and public use E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","norm_bases":["PN-EN 581-1","PN-EN 581-2","PN-EN 581-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do użytkowania na zewnątrz – meble do siedzenia i stoły użytkowane na kempingu, na zewnątrz domu i w miejscach publicznych E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3 Meble do uzytkowania na zewnatrz – meble do siedzenia i stoly uzytkowane na kempingu, na zewnatrz domu i w miejscach publicznych E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Outdoor furniture – seating and tables for camping, domestic outdoor and public use E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b360","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do użytkowania na zewnątrz – meble do siedzenia i stoły użytkowane na kempingu, na zewnątrz domu i w miejscach publicznych E","test_object_en":"Outdoor furniture – seating and tables for camping, domestic outdoor and public use E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","norm_bases":["PN-EN 581-1","PN-EN 581-2","PN-EN 581-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do użytkowania na zewnątrz – meble do siedzenia i stoły użytkowane na kempingu, na zewnątrz domu i w miejscach publicznych E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3 Meble do uzytkowania na zewnatrz – meble do siedzenia i stoly uzytkowane na kempingu, na zewnatrz domu i w miejscach publicznych E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Outdoor furniture – seating and tables for camping, domestic outdoor and public use E Geometric dimensions Method: direct measurement Range Range PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 581-1 | PN-EN 581-2 | PN-EN 581-3","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b361","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Stołki rozkładane E","test_object_en":"Folding stools E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, próba stanowiskowa"],"technique_en":"Method: force and/or mass loading, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa","reference":"PN-EN 14183","norm_bases":["PN-EN 14183"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stołki rozkładane E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa PN-EN 14183 Stolki rozkladane E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, proba stanowiskowa PN-EN 14183","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Folding stools E Strength of construction Method: force and/or mass loading, bench test Range Range Range PN-EN 14183","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、台架试验 范围 范围 范围 PN-EN 14183","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b362","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Stołki rozkładane E","test_object_en":"Folding stools E","methodology":"Współczynnik tarcia","methodology_en":"Friction coefficient","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar pośredni, obciążenie siłą i/lub masą","techniques":["Metoda: pomiar pośredni, obciążenie siłą i/lub masą"],"technique_en":"Method: indirect measurement, loading with force and/or mass","computed":[],"computed_en":[],"activity":"Współczynnik tarcia\nMetoda: pomiar pośredni, obciążenie siłą i/lub masą","reference":"PN-EN 14183","norm_bases":["PN-EN 14183"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stołki rozkładane E Współczynnik tarcia\nMetoda: pomiar pośredni, obciążenie siłą i/lub masą PN-EN 14183 Stolki rozkladane E Wspolczynnik tarcia\nMetoda: pomiar posredni, obciazenie sila i/lub masa PN-EN 14183","categories":["other"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Folding stools E Friction coefficient Method: indirect measurement, loading with force and/or mass PN-EN 14183","methodology_zh":"摩擦系数","search_zh":"摩擦系数 PN-EN 14183"},{"_id":"6a5e78454cc76d93cba3b363","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Stołki rozkładane E","test_object_en":"Folding stools E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 14183","norm_bases":["PN-EN 14183"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Stołki rozkładane E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 14183 Stolki rozkladane E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 14183","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Folding stools E Geometric dimensions Method: direct measurement Range Range PN-EN 14183","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 14183","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b364","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble –, Łóżeczka i kołyski mieszkaniowe E","test_object_en":"Furniture –, Domestic cots and cradles E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 1130","norm_bases":["PN-EN 1130"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble –, Łóżeczka i kołyski mieszkaniowe E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 1130 Meble –, Lozeczka i kolyski mieszkaniowe E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 1130","categories":["other"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture –, Domestic cots and cradles E Stability Method: loading with force and/or mass Range Range PN-EN 1130","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 1130","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b365","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble –, Łóżeczka i kołyski mieszkaniowe E","test_object_en":"Furniture –, Domestic cots and cradles E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1130","norm_bases":["PN-EN 1130"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble –, Łóżeczka i kołyski mieszkaniowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1130 Meble –, Lozeczka i kolyski mieszkaniowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1130","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture –, Domestic cots and cradles E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range Range PN-EN 1130","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 PN-EN 1130","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b366","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble –, Łóżeczka i kołyski mieszkaniowe E","test_object_en":"Furniture –, Domestic cots and cradles E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 1130","norm_bases":["PN-EN 1130"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble –, Łóżeczka i kołyski mieszkaniowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 1130 Meble –, Lozeczka i kolyski mieszkaniowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 1130","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture –, Domestic cots and cradles E Geometric dimensions Method: direct measurement Range Range PN-EN 1130","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 1130","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b367","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki E","test_object_en":"Toys E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"odporność na moczenie"},{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 11,5) Nm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"resistance to soaking"},{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 11,5) Nm"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia"],"technique_en":"Method: force and/or mass and/or torque loading, probe test, bench test, soaking test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nodporność na moczenie\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11,5) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia","reference":"PN-EN 71-1","norm_bases":["PN-EN 71-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nodporność na moczenie\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11,5) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia PN-EN 71-1 Zabawki E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\nodpornosc na moczenie\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11,5) Nm\nMetoda: obciazenie sila i/lub masa i/lub momentem, badanie probnikiem, proba stanowiskowa, proba moczenia PN-EN 71-1","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys E Strength of construction Method: force and/or mass and/or torque loading, probe test, bench test, soaking test strength of the product and its components, resistance to soaking Range Range Range Range Range PN-EN 71-1","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐浸湿性"},{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 11,5) Nm"}],"search_zh":"玩具 E 结构强度 制品及其部件的强度， 耐浸湿性 范围 范围 范围 范围 范围 PN-EN 71-1","methodology_zh":"结构强度","test_object_zh":"玩具 E"},{"_id":"6a5e78454cc76d93cba3b368","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki E","test_object_en":"Toys E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"},{"name":"Zakres","range":"(0 - 800) μm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"},{"name":"Range","range":"(0 - 800) μm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem, próba cylindra do badania małych części, metoda magnetyczna","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem, próba cylindra do badania małych części, metoda magnetyczna"],"technique_en":"Method: direct measurement, testing with a probe, small parts cylinder test, magnetic method","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezpośredni, badanie próbnikiem, próba cylindra do badania małych części, metoda magnetyczna","reference":"PN-EN 71-1","norm_bases":["PN-EN 71-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezpośredni, badanie próbnikiem, próba cylindra do badania małych części, metoda magnetyczna PN-EN 71-1 Zabawki E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezposredni, badanie probnikiem, proba cylindra do badania malych czesci, metoda magnetyczna PN-EN 71-1","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys E Geometric dimensions Method: direct measurement, testing with a probe, small parts cylinder test, magnetic method Range Range Range PN-EN 71-1","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"},{"name":"范围","range":"(0 - 800) μm"}],"search_zh":"玩具 E 几何尺寸 范围 范围 范围 PN-EN 71-1","methodology_zh":"几何尺寸","test_object_zh":"玩具 E"},{"_id":"6a5e78454cc76d93cba3b369","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki E","test_object_en":"Toys E","methodology":"Ostrość krawędzi – długość nacięcia taśmy","methodology_en":"Edge sharpness – length of tape cut","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Ostrość krawędzi – długość nacięcia taśmy\nMetoda: pomiar bezpośredni","reference":"PN-EN 71-1","norm_bases":["PN-EN 71-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki E Ostrość krawędzi – długość nacięcia taśmy\nMetoda: pomiar bezpośredni PN-EN 71-1 Zabawki E Ostrosc krawedzi – dlugosc naciecia tasmy\nMetoda: pomiar bezposredni PN-EN 71-1","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys E Edge sharpness – length of tape cut Method: direct measurement PN-EN 71-1","search_zh":"玩具 E 方法：直接测量 PN-EN 71-1","technique_zh":"方法：直接测量","test_object_zh":"玩具 E"},{"_id":"6a5e78454cc76d93cba3b36a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki E","test_object_en":"Toys E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 30) °"}],"parameters_en":[{"name":"Range","range":"(0 - 30) °"}],"technique":"Metoda: próba stanowiskowa","techniques":["Metoda: próba stanowiskowa"],"technique_en":"Method: bench test","computed":[],"computed_en":[],"activity":"Stateczność\nZakres (0 - 30) °\nMetoda: próba stanowiskowa","reference":"PN-EN 71-1","norm_bases":["PN-EN 71-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki E Stateczność\nZakres (0 - 30) °\nMetoda: próba stanowiskowa PN-EN 71-1 Zabawki E Statecznosc\nZakres (0 - 30) °\nMetoda: proba stanowiskowa PN-EN 71-1","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys E Stability Method: bench test Range PN-EN 71-1","parameters_zh":[{"name":"范围","range":"(0 - 30) °"}],"search_zh":"玩具 E 稳定性 范围 PN-EN 71-1","methodology_zh":"稳定性","test_object_zh":"玩具 E"},{"_id":"6a5e78454cc76d93cba3b36b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki E","test_object_en":"Toys E","methodology":"Ostrość zakończeń","methodology_en":"Sharpness of points","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar głowicą testową","techniques":["Metoda: pomiar głowicą testową"],"technique_en":"Method: measurement with a test head","computed":[],"computed_en":[],"activity":"Ostrość zakończeń\nMetoda: pomiar głowicą testową","reference":"PN-EN 71-1","norm_bases":["PN-EN 71-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki E Ostrość zakończeń\nMetoda: pomiar głowicą testową PN-EN 71-1 Zabawki E Ostrosc zakonczen\nMetoda: pomiar glowica testowa PN-EN 71-1","categories":["other"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys E Sharpness of points Method: measurement with a test head PN-EN 71-1","search_zh":"玩具 E PN-EN 71-1","test_object_zh":"玩具 E"},{"_id":"6a5e78454cc76d93cba3b36c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E","test_object_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 71-8","norm_bases":["PN-EN 71-8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 71-8 Zabawki – Hustawki, zjezdzalnie i podobne zabawki aktywizujace przeznaczone do uzytku domowego – wewnatrz i na zewnatrz E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 71-8","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E Stability Method: loading with force and/or mass Range Range PN-EN 71-8","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E 稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 71-8","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷","test_object_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E"},{"_id":"6a5e78454cc76d93cba3b36d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E","test_object_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 1500) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 1500) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 71-8","norm_bases":["PN-EN 71-8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 71-8 Zabawki – Hustawki, zjezdzalnie i podobne zabawki aktywizujace przeznaczone do uzytku domowego – wewnatrz i na zewnatrz E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 71-8","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E Strength of construction Method: loading with force and/or mass, probe testing, bench test Range Range Range Range PN-EN 71-8","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 1500) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 范围 范围 范围 范围 PN-EN 71-8","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E"},{"_id":"6a5e78454cc76d93cba3b36e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E","test_object_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E","methodology":"Amortyzacja uderzeń siedzisk huśtawki","methodology_en":"Impact attenuation of swing seats","parameters":[{"name":"Zakres","range":"(0 - 200) g;"},{"name":"Zakres","range":"(0 - 1000) N/cm2"}],"parameters_en":[{"name":"Range","range":"(0 - 200) g;"},{"name":"Range","range":"(0 - 1000) N/cm2"}],"technique":"Metoda: badanie modelem głowy","techniques":["Metoda: badanie modelem głowy"],"technique_en":"Method: headform test","computed":[],"computed_en":[],"activity":"Amortyzacja uderzeń siedzisk huśtawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem głowy","reference":"PN-EN 71-8","norm_bases":["PN-EN 71-8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E Amortyzacja uderzeń siedzisk huśtawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem głowy PN-EN 71-8 Zabawki – Hustawki, zjezdzalnie i podobne zabawki aktywizujace przeznaczone do uzytku domowego – wewnatrz i na zewnatrz E Amortyzacja uderzen siedzisk hustawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem glowy PN-EN 71-8","categories":["other"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E Impact attenuation of swing seats Method: headform test Range Range PN-EN 71-8","parameters_zh":[{"name":"范围","range":"(0 - 200) g;"},{"name":"范围","range":"(0 - 1000) N/cm2"}],"search_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E 方法：头部模型试验 范围 范围 PN-EN 71-8","technique_zh":"方法：头部模型试验","test_object_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E"},{"_id":"6a5e78454cc76d93cba3b36f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E","test_object_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 20000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 20000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 71-8","norm_bases":["PN-EN 71-8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zabawki – Huśtawki, zjeżdżalnie i podobne zabawki aktywizujące przeznaczone do użytku domowego – wewnątrz i na zewnątrz E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 71-8 Zabawki – Hustawki, zjezdzalnie i podobne zabawki aktywizujace przeznaczone do uzytku domowego – wewnatrz i na zewnatrz E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 71-8","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Toys – Swings, slides and similar activity toys for indoor and outdoor family domestic use E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 71-8","parameters_zh":[{"name":"范围","range":"(0 - 20000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E 几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 71-8","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"玩具 － 家庭使用的秋千、滑梯及类似活动玩具 － 室内与室外 E"},{"_id":"6a5e78454cc76d93cba3b370","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia sportowe i rekreacyjne - Tory linowe E","test_object_en":"Sports and recreational equipment - Rope courses E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 50) m;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 50) m;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 50) m;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 15567-1","norm_bases":["PN-EN 15567-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sportowe i rekreacyjne - Tory linowe E Wymiary geometryczne\nZakres:\nZakres (0 - 50) m;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 15567-1 Urzadzenia sportowe i rekreacyjne - Tory linowe E Wymiary geometryczne\nZakres:\nZakres (0 - 50) m;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 15567-1","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sports and recreational equipment - Rope courses E Geometric dimensions Method: direct measurement Range Range PN-EN 15567-1","parameters_zh":[{"name":"范围","range":"(0 - 50) m;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 15567-1","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b371","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia sportowe i rekreacyjne - Tory linowe E","test_object_en":"Sports and recreational equipment - Rope courses E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"moment dokręcania"},{"name":"Zakres","range":"(0 - 50) kN;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 200) Nm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"tightening torque"},{"name":"Range","range":"(0 - 50) kN;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 200) Nm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem"],"technique_en":"Method: force and/or mass loading, probe test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nmoment dokręcania\nZakres (0 - 50) kN;\nZakres (0 - 450) kg;\nZakres (0 - 200) Nm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem","reference":"PN-EN 15567-1","norm_bases":["PN-EN 15567-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sportowe i rekreacyjne - Tory linowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nmoment dokręcania\nZakres (0 - 50) kN;\nZakres (0 - 450) kg;\nZakres (0 - 200) Nm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem PN-EN 15567-1 Urzadzenia sportowe i rekreacyjne - Tory linowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\nmoment dokrecania\nZakres (0 - 50) kN;\nZakres (0 - 450) kg;\nZakres (0 - 200) Nm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem PN-EN 15567-1","categories":["other"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sports and recreational equipment - Rope courses E Strength of construction Method: force and/or mass loading, probe test strength of the product and its components, tightening torque Range Range Range PN-EN 15567-1","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"moment dokręcania"},{"name":"范围","range":"(0 - 50) kN;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 200) Nm"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、探棒试验 制品及其部件的强度， 范围 范围 范围 PN-EN 15567-1","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、探棒试验"},{"_id":"6a5e78454cc76d93cba3b372","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia sportowe i rekreacyjne - Tory linowe E","test_object_en":"Sports and recreational equipment - Rope courses E","methodology":"Uwięźnięcie głowy i szyi, palców, nóg, całego ciała","methodology_en":"Entrapment of the head and neck, fingers, legs, whole body","parameters":[],"parameters_en":[],"technique":"Metoda: badanie próbnikiem","techniques":["Metoda: badanie próbnikiem"],"technique_en":"Method: testing with a probe","computed":[],"computed_en":[],"activity":"Uwięźnięcie głowy i szyi, palców, nóg, całego ciała\nMetoda: badanie próbnikiem","reference":"PN-EN 15567-1","norm_bases":["PN-EN 15567-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia sportowe i rekreacyjne - Tory linowe E Uwięźnięcie głowy i szyi, palców, nóg, całego ciała\nMetoda: badanie próbnikiem PN-EN 15567-1 Urzadzenia sportowe i rekreacyjne - Tory linowe E Uwiezniecie glowy i szyi, palcow, nog, calego ciala\nMetoda: badanie probnikiem PN-EN 15567-1","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sports and recreational equipment - Rope courses E Entrapment of the head and neck, fingers, legs, whole body Method: testing with a probe PN-EN 15567-1"},{"_id":"6a5e78454cc76d93cba3b373","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw E","test_object_en":"Playground equipment E","methodology":"Wytrzymałość konstrukcji, stateczność","methodology_en":"Structural strength, stability","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 1500) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 1500) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji, stateczność\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1176-1","norm_bases":["PN-EN 1176-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw E Wytrzymałość konstrukcji, stateczność\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1176-1 Wyposazenie placow zabaw E Wytrzymalosc konstrukcji, statecznosc\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 1500) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1176-1","categories":["other"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment E Structural strength, stability Method: loading with force and/or mass, probe testing, bench test Range Range Range PN-EN 1176-1","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 1500) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"方法：施加力和/或质量载荷、探头检测、台架试验 范围 范围 范围 PN-EN 1176-1","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b374","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw E","test_object_en":"Playground equipment E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 20000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 20000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1176-1","norm_bases":["PN-EN 1176-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1176-1 Wyposazenie placow zabaw E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1176-1","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1176-1","parameters_zh":[{"name":"范围","range":"(0 - 20000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1176-1","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b375","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw – zjeżdżalnie E","test_object_en":"Playground equipment – slides E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 20000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 20000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 1176-3","norm_bases":["PN-EN 1176-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw – zjeżdżalnie E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 1176-3 Wyposazenie placow zabaw – zjezdzalnie E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 1176-3","categories":["other"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment – slides E Geometric dimensions Method: direct measurement Range Range PN-EN 1176-3","parameters_zh":[{"name":"范围","range":"(0 - 20000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 1176-3","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b376","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw – karuzele E","test_object_en":"Playground equipment – roundabouts E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 20000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 20000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 20000) mm\nMetoda: pomiar bezpośredni","reference":"P N - E N 1 1 7 6 -5 IP-TÜV-02","norm_bases":["P N - E N 1 1 7 6 -5 IP-TÜV-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw – karuzele E Wymiary geometryczne\nZakres (0 - 20000) mm\nMetoda: pomiar bezpośredni P N - E N 1 1 7 6 -5 IP-TÜV-02 Wyposazenie placow zabaw – karuzele E Wymiary geometryczne\nZakres (0 - 20000) mm\nMetoda: pomiar bezposredni P N - E N 1 1 7 6 -5 IP-TUV-02","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment – roundabouts E Geometric dimensions Method: direct measurement Range P N - E N 1 1 7 6 -5 IP-TÜV-02","parameters_zh":[{"name":"范围","range":"(0 - 20000) mm"}],"search_zh":"几何尺寸 方法：直接测量 范围 P N - E N 1 1 7 6 -5 IP-TÜV-02","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b377","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw – karuzele E","test_object_en":"Playground equipment – roundabouts E","methodology":"Prędkość obwodowa karuzeli","methodology_en":"Peripheral speed of the carousel","parameters":[{"name":"Zakres","range":"(0 - 5) m/s"}],"parameters_en":[{"name":"Range","range":"(0 - 5) m/s"}],"technique":"Metoda: pomiar pośredni","techniques":["Metoda: pomiar pośredni"],"technique_en":"Method: indirect measurement","computed":[],"computed_en":[],"activity":"Prędkość obwodowa karuzeli\nZakres (0 - 5) m/s\nMetoda: pomiar pośredni","reference":"P N - E N 1 1 7 6 -5 IP-TÜV-02","norm_bases":["P N - E N 1 1 7 6 -5 IP-TÜV-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw – karuzele E Prędkość obwodowa karuzeli\nZakres (0 - 5) m/s\nMetoda: pomiar pośredni P N - E N 1 1 7 6 -5 IP-TÜV-02 Wyposazenie placow zabaw – karuzele E Predkosc obwodowa karuzeli\nZakres (0 - 5) m/s\nMetoda: pomiar posredni P N - E N 1 1 7 6 -5 IP-TUV-02","categories":["other"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment – roundabouts E Peripheral speed of the carousel Method: indirect measurement Range P N - E N 1 1 7 6 -5 IP-TÜV-02","parameters_zh":[{"name":"范围","range":"(0 - 5) m/s"}],"search_zh":"方法：间接测量 范围 P N - E N 1 1 7 6 -5 IP-TÜV-02","technique_zh":"方法：间接测量"},{"_id":"6a5e78454cc76d93cba3b378","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw – urządzenia kołyszące E","test_object_en":"Playground equipment – rocking equipment E","methodology":"Stabilność, odchylenie boczne","methodology_en":"Stability, lateral deflection","parameters":[{"name":"Zakres","range":"(0 - 90) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 90) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem"],"technique_en":"Method: force and/or mass loading, probe test","computed":[],"computed_en":[],"activity":"Stabilność, odchylenie boczne\nZakres:\nZakres (0 - 90) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem","reference":"PN-EN 1176-6","norm_bases":["PN-EN 1176-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw – urządzenia kołyszące E Stabilność, odchylenie boczne\nZakres:\nZakres (0 - 90) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem PN-EN 1176-6 Wyposazenie placow zabaw – urzadzenia kolyszace E Stabilnosc, odchylenie boczne\nZakres:\nZakres (0 - 90) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem PN-EN 1176-6","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment – rocking equipment E Stability, lateral deflection Method: force and/or mass loading, probe test Range Range PN-EN 1176-6","parameters_zh":[{"name":"范围","range":"(0 - 90) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"方法：加力和/或加质量载荷、探棒试验 范围 范围 PN-EN 1176-6","technique_zh":"方法：加力和/或加质量载荷、探棒试验"},{"_id":"6a5e78454cc76d93cba3b379","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw – urządzenia kołyszące E","test_object_en":"Playground equipment – rocking equipment E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1176-6","norm_bases":["PN-EN 1176-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw – urządzenia kołyszące E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1176-6 Wyposazenie placow zabaw – urzadzenia kolyszace E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1176-6","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment – rocking equipment E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1176-6","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1176-6","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b37a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw - dokumentacja dotycząca instalowania, kontroli, konserwacji i eksploatacji E","test_object_en":"Playground equipment - documentation on installation, inspection, maintenance and operation E","methodology":"Wymiary geometryczne oraz kompletność oznakowania","methodology_en":"Geometric dimensions and completeness of marking","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne oraz kompletność oznakowania\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN 1176-7","norm_bases":["PN-EN 1176-7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw - dokumentacja dotycząca instalowania, kontroli, konserwacji i eksploatacji E Wymiary geometryczne oraz kompletność oznakowania\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni PN-EN 1176-7 Wyposazenie placow zabaw - dokumentacja dotyczaca instalowania, kontroli, konserwacji i eksploatacji E Wymiary geometryczne oraz kompletnosc oznakowania\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni PN-EN 1176-7","categories":["other"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment - documentation on installation, inspection, maintenance and operation E Geometric dimensions and completeness of marking Method: direct measurement Range PN-EN 1176-7","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"方法：直接测量 范围 PN-EN 1176-7","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b37b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw – całkowicie obudowane urządzenia do zabawy E","test_object_en":"Playground equipment – fully enclosed play equipment E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 1176-10","norm_bases":["PN-EN 1176-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw – całkowicie obudowane urządzenia do zabawy E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 1176-10 Wyposazenie placow zabaw – calkowicie obudowane urzadzenia do zabawy E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 1176-10","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment – fully enclosed play equipment E Geometric dimensions Method: direct measurement Range Range PN-EN 1176-10","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 1176-10","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b37c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw – sieci przestrzenne E","test_object_en":"Playground equipment – spatial networks E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 1176-11","norm_bases":["PN-EN 1176-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw – sieci przestrzenne E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 1176-11 Wyposazenie placow zabaw – sieci przestrzenne E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 1176-11","categories":["other"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment – spatial networks E Geometric dimensions Method: direct measurement Range Range PN-EN 1176-11","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 1176-11","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b37d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1888-1 | PN-EN 1888-2","norm_bases":["PN-EN 1888-1","PN-EN 1888-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1888-1 | PN-EN 1888-2 Artykuly dla dzieci – Wozki dzieciece E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1888-1 | PN-EN 1888-2","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1888-1 | PN-EN 1888-2","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"儿童用品 － 童车 E 几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1888-1 | PN-EN 1888-2","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"儿童用品 － 童车 E"},{"_id":"6a5e78454cc76d93cba3b37e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 30) °"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 30) °"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa"],"technique_en":"Method: force and/or mass and/or torque loading, bench test","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","reference":"PN-EN 1888-1 | PN-EN 1888-2","norm_bases":["PN-EN 1888-1","PN-EN 1888-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa PN-EN 1888-1 | PN-EN 1888-2 Artykuly dla dzieci – Wozki dzieciece E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciazenie sila i/lub masa i/lub momentem, proba stanowiskowa PN-EN 1888-1 | PN-EN 1888-2","categories":["other"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Stability Method: force and/or mass and/or torque loading, bench test Range Range Range PN-EN 1888-1 | PN-EN 1888-2","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 30) °"}],"search_zh":"儿童用品 － 童车 E 稳定性 方法：加力和/或加质量和/或加力矩载荷、台架试验 范围 范围 范围 PN-EN 1888-1 | PN-EN 1888-2","methodology_zh":"稳定性","test_object_zh":"儿童用品 － 童车 E","technique_zh":"方法：加力和/或加质量和/或加力矩载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b37f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość,"},{"name":"skręcanie"},{"name":"Zakres","range":"(0 - 1000) N;"},{"name":"Zakres","range":"(0 - 100) kg;"},{"name":"Zakres","range":"(0 - 0,34) Nm;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 5) km/h"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability,"},{"name":"torsion"},{"name":"Range","range":"(0 - 1000) N;"},{"name":"Range","range":"(0 - 100) kg;"},{"name":"Range","range":"(0 - 0,34) Nm;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 5) km/h"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) km/h\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1888-1 | PN-EN 1888-2","norm_bases":["PN-EN 1888-1","PN-EN 1888-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) km/h\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1888-1 | PN-EN 1888-2 Artykuly dla dzieci – Wozki dzieciece E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc,\nskrecanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) km/h\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1888-1 | PN-EN 1888-2","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability, torsion Range Range Range Range Range Range PN-EN 1888-1 | PN-EN 1888-2","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性，"},{"name":"扭转"},{"name":"范围","range":"(0 - 1000) N;"},{"name":"范围","range":"(0 - 100) kg;"},{"name":"范围","range":"(0 - 0,34) Nm;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 5) km/h"}],"search_zh":"儿童用品 － 童车 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性， 扭转 范围 范围 范围 范围 范围 范围 PN-EN 1888-1 | PN-EN 1888-2","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"儿童用品 － 童车 E"},{"_id":"6a5e78454cc76d93cba3b380","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble - Łóżka dziecięce i łóżka dziecięce składane mieszkaniowe E","test_object_en":"Furniture - Children's cots and folding cots for domestic use E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 11) Nm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 11) Nm"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: force and/or mass and/or torque loading, probe test, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 716-1 | PN-EN 716-2","norm_bases":["PN-EN 716-1","PN-EN 716-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble - Łóżka dziecięce i łóżka dziecięce składane mieszkaniowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa PN-EN 716-1 | PN-EN 716-2 Meble - Lozka dzieciece i lozka dzieciece skladane mieszkaniowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciazenie sila i/lub masa i/lub momentem, badanie probnikiem, proba stanowiskowa PN-EN 716-1 | PN-EN 716-2","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture - Children's cots and folding cots for domestic use E Strength of construction Method: force and/or mass and/or torque loading, probe test, bench test strength of the product and its components, durability Range Range Range Range Range PN-EN 716-1 | PN-EN 716-2","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 11) Nm"}],"search_zh":"结构强度 制品及其部件的强度， 耐久性 范围 范围 范围 范围 范围 PN-EN 716-1 | PN-EN 716-2","methodology_zh":"结构强度"},{"_id":"6a5e78454cc76d93cba3b381","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble - Łóżka dziecięce i łóżka dziecięce składane mieszkaniowe E","test_object_en":"Furniture - Children's cots and folding cots for domestic use E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 716-1 | PN-EN 716-2","norm_bases":["PN-EN 716-1","PN-EN 716-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble - Łóżka dziecięce i łóżka dziecięce składane mieszkaniowe E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 716-1 | PN-EN 716-2 Meble - Lozka dzieciece i lozka dzieciece skladane mieszkaniowe E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 716-1 | PN-EN 716-2","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture - Children's cots and folding cots for domestic use E Stability Method: loading with force and/or mass Range Range PN-EN 716-1 | PN-EN 716-2","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 716-1 | PN-EN 716-2","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b382","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble - Łóżka dziecięce i łóżka dziecięce składane mieszkaniowe E","test_object_en":"Furniture - Children's cots and folding cots for domestic use E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, pomiar próbnikiem","techniques":["Metoda: pomiar bezpośredni, pomiar próbnikiem"],"technique_en":"Method: direct measurement, probe measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, pomiar próbnikiem","reference":"PN-EN 716-1 | PN-EN 716-2","norm_bases":["PN-EN 716-1","PN-EN 716-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble - Łóżka dziecięce i łóżka dziecięce składane mieszkaniowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, pomiar próbnikiem PN-EN 716-1 | PN-EN 716-2 Meble - Lozka dzieciece i lozka dzieciece skladane mieszkaniowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, pomiar probnikiem PN-EN 716-1 | PN-EN 716-2","categories":["other"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture - Children's cots and folding cots for domestic use E Geometric dimensions Method: direct measurement, probe measurement Range Range PN-EN 716-1 | PN-EN 716-2","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探棒测量 范围 范围 PN-EN 716-1 | PN-EN 716-2","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探棒测量"},{"_id":"6a5e78454cc76d93cba3b383","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Łóżka piętrowe i łóżka wysokie E","test_object_en":"Furniture – Bunk beds and high beds E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 747-1 | PN-EN 747-2","norm_bases":["PN-EN 747-1","PN-EN 747-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Łóżka piętrowe i łóżka wysokie E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 747-1 | PN-EN 747-2 Meble – Lozka pietrowe i lozka wysokie E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 747-1 | PN-EN 747-2","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Bunk beds and high beds E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range PN-EN 747-1 | PN-EN 747-2","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 747-1 | PN-EN 747-2","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b384","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Łóżka piętrowe i łóżka wysokie E","test_object_en":"Furniture – Bunk beds and high beds E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 747-1 | PN-EN 747-2","norm_bases":["PN-EN 747-1","PN-EN 747-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Łóżka piętrowe i łóżka wysokie E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 747-1 | PN-EN 747-2 Meble – Lozka pietrowe i lozka wysokie E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 747-1 | PN-EN 747-2","categories":["other"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Bunk beds and high beds E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 747-1 | PN-EN 747-2","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 747-1 | PN-EN 747-2","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b385","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Łóżka piętrowe i łóżka wysokie E","test_object_en":"Furniture – Bunk beds and high beds E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 747-1 | PN-EN 747-2","norm_bases":["PN-EN 747-1","PN-EN 747-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Łóżka piętrowe i łóżka wysokie E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 747-1 | PN-EN 747-2 Meble – Lozka pietrowe i lozka wysokie E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 747-1 | PN-EN 747-2","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Bunk beds and high beds E Stability Method: loading with force and/or mass Range Range PN-EN 747-1 | PN-EN 747-2","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 747-1 | PN-EN 747-2","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b386","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E","test_object_en":"Child care articles - Changing units for domestic use E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, pomiar próbnikiem","techniques":["Metoda: pomiar bezpośredni, pomiar próbnikiem"],"technique_en":"Method: direct measurement, probe measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, pomiar próbnikiem","reference":"PN-EN 12221-1 | PN-EN 12221-2","norm_bases":["PN-EN 12221-1","PN-EN 12221-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, pomiar próbnikiem PN-EN 12221-1 | PN-EN 12221-2 Artykuly dla dzieci - Przewijaki niemowlece do uzytku domowego E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, pomiar probnikiem PN-EN 12221-1 | PN-EN 12221-2","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles - Changing units for domestic use E Geometric dimensions Method: direct measurement, probe measurement Range Range PN-EN 12221-1 | PN-EN 12221-2","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"儿童用品 － 家用婴儿尿布台 E 几何尺寸 方法：直接测量、探棒测量 范围 范围 PN-EN 12221-1 | PN-EN 12221-2","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探棒测量","test_object_zh":"儿童用品 － 家用婴儿尿布台 E"},{"_id":"6a5e78454cc76d93cba3b387","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E","test_object_en":"Child care articles - Changing units for domestic use E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 12221-1 | PN-EN 12221-2","norm_bases":["PN-EN 12221-1","PN-EN 12221-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 12221-1 | PN-EN 12221-2 Artykuly dla dzieci - Przewijaki niemowlece do uzytku domowego E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 12221-1 | PN-EN 12221-2","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles - Changing units for domestic use E Stability Method: loading with force and/or mass Range Range PN-EN 12221-1 | PN-EN 12221-2","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"儿童用品 － 家用婴儿尿布台 E 稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 12221-1 | PN-EN 12221-2","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷","test_object_zh":"儿童用品 － 家用婴儿尿布台 E"},{"_id":"6a5e78454cc76d93cba3b388","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E","test_object_en":"Child care articles - Changing units for domestic use E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 12221-1 | PN-EN 12221-2","norm_bases":["PN-EN 12221-1","PN-EN 12221-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 12221-1 | PN-EN 12221-2 Artykuly dla dzieci - Przewijaki niemowlece do uzytku domowego E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 12221-1 | PN-EN 12221-2","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles - Changing units for domestic use E Strength of construction Method: loading with force and/or mass, probe testing, bench test Range Range Range Range PN-EN 12221-1 | PN-EN 12221-2","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"儿童用品 － 家用婴儿尿布台 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 范围 范围 范围 范围 PN-EN 12221-1 | PN-EN 12221-2","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"儿童用品 － 家用婴儿尿布台 E"},{"_id":"6a5e78454cc76d93cba3b389","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E","test_object_en":"Child care articles - Changing units for domestic use E","methodology":"Wytrzymałość temperaturowa","methodology_en":"Temperature endurance","parameters":[{"name":"Zakres","range":"(0 - 100) °C"}],"parameters_en":[{"name":"Range","range":"(0 - 100) °C"}],"technique":"Metoda: próba stanowiskowa","techniques":["Metoda: próba stanowiskowa"],"technique_en":"Method: bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość temperaturowa\nZakres (0 - 100) °C\nMetoda: próba stanowiskowa","reference":"PN-EN 12221-1 | PN-EN 12221-2","norm_bases":["PN-EN 12221-1","PN-EN 12221-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci - Przewijaki niemowlęce do użytku domowego E Wytrzymałość temperaturowa\nZakres (0 - 100) °C\nMetoda: próba stanowiskowa PN-EN 12221-1 | PN-EN 12221-2 Artykuly dla dzieci - Przewijaki niemowlece do uzytku domowego E Wytrzymalosc temperaturowa\nZakres (0 - 100) °C\nMetoda: proba stanowiskowa PN-EN 12221-1 | PN-EN 12221-2","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles - Changing units for domestic use E Temperature endurance Method: bench test Range PN-EN 12221-1 | PN-EN 12221-2","parameters_zh":[{"name":"范围","range":"(0 - 100) °C"}],"search_zh":"儿童用品 － 家用婴儿尿布台 E 范围 PN-EN 12221-1 | PN-EN 12221-2","test_object_zh":"儿童用品 － 家用婴儿尿布台 E"},{"_id":"6a5e78454cc76d93cba3b38a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania użytkowane poza mieszkaniem E","test_object_en":"Non-domestic storage furniture E","methodology":"Masa wyrobu i jego elementów","methodology_en":"Mass of the product and its components","parameters":[{"name":"Zakres","range":"(0 - 150) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 150) kg"}],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"technique_en":"Method: gravimetric","computed":[],"computed_en":[],"activity":"Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa","reference":"PN-EN 16121 | PN-EN 16122","norm_bases":["PN-EN 16121","PN-EN 16122"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania użytkowane poza mieszkaniem E Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 16121 | PN-EN 16122 Meble do przechowywania uzytkowane poza mieszkaniem E Masa wyrobu i jego elementow\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 16121 | PN-EN 16122","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Non-domestic storage furniture E Mass of the product and its components Method: gravimetric Range PN-EN 16121 | PN-EN 16122","parameters_zh":[{"name":"范围","range":"(0 - 150) kg"}],"search_zh":"住宅以外使用的贮存家具 E 制品及其部件的质量 方法：重量法 范围 PN-EN 16121 | PN-EN 16122","technique_zh":"方法：重量法","methodology_zh":"制品及其部件的质量","test_object_zh":"住宅以外使用的贮存家具 E"},{"_id":"6a5e78454cc76d93cba3b38b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania użytkowane poza mieszkaniem E","test_object_en":"Non-domestic storage furniture E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, pomiar próbnikiem","techniques":["Metoda: pomiar bezpośredni, pomiar próbnikiem"],"technique_en":"Method: direct measurement, probe measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, pomiar próbnikiem","reference":"PN-EN 16121 | PN-EN 16122","norm_bases":["PN-EN 16121","PN-EN 16122"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania użytkowane poza mieszkaniem E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, pomiar próbnikiem PN-EN 16121 | PN-EN 16122 Meble do przechowywania uzytkowane poza mieszkaniem E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, pomiar probnikiem PN-EN 16121 | PN-EN 16122","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Non-domestic storage furniture E Geometric dimensions Method: direct measurement, probe measurement Range Range PN-EN 16121 | PN-EN 16122","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"住宅以外使用的贮存家具 E 几何尺寸 方法：直接测量、探棒测量 范围 范围 PN-EN 16121 | PN-EN 16122","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探棒测量","test_object_zh":"住宅以外使用的贮存家具 E"},{"_id":"6a5e78454cc76d93cba3b38c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania użytkowane poza mieszkaniem E","test_object_en":"Non-domestic storage furniture E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 16121 | PN-EN 16122","norm_bases":["PN-EN 16121","PN-EN 16122"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania użytkowane poza mieszkaniem E Stateczność\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą PN-EN 16121 | PN-EN 16122 Meble do przechowywania uzytkowane poza mieszkaniem E Statecznosc\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa PN-EN 16121 | PN-EN 16122","categories":["other"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Non-domestic storage furniture E Stability Method: loading with force and/or mass Range Range Range PN-EN 16121 | PN-EN 16122","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"住宅以外使用的贮存家具 E 稳定性 方法：施加力和/或质量载荷 范围 范围 范围 PN-EN 16121 | PN-EN 16122","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷","test_object_zh":"住宅以外使用的贮存家具 E"},{"_id":"6a5e78454cc76d93cba3b38d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania użytkowane poza mieszkaniem E","test_object_en":"Non-domestic storage furniture E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 5) m/s"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 5) m/s"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) m/s\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 16121 | PN-EN 16122","norm_bases":["PN-EN 16121","PN-EN 16122"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania użytkowane poza mieszkaniem E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) m/s\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 16121 | PN-EN 16122 Meble do przechowywania uzytkowane poza mieszkaniem E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) m/s\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 16121 | PN-EN 16122","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Non-domestic storage furniture E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range Range Range PN-EN 16121 | PN-EN 16122","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 5) m/s"}],"search_zh":"住宅以外使用的贮存家具 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 范围 PN-EN 16121 | PN-EN 16122","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"住宅以外使用的贮存家具 E"},{"_id":"6a5e78454cc76d93cba3b38e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble mieszkaniowe - Łóżka i materace E","test_object_en":"Domestic furniture - Beds and mattresses E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni, pomiar próbnikiem","techniques":["Metoda: pomiar bezpośredni, pomiar próbnikiem"],"technique_en":"Method: direct measurement, probe measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, pomiar próbnikiem","reference":"PN-EN 1725","norm_bases":["PN-EN 1725"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble mieszkaniowe - Łóżka i materace E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, pomiar próbnikiem PN-EN 1725 Meble mieszkaniowe - Lozka i materace E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni, pomiar probnikiem PN-EN 1725","categories":["other"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Domestic furniture - Beds and mattresses E Geometric dimensions Method: direct measurement, probe measurement Range PN-EN 1725","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量、探棒测量 范围 PN-EN 1725","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探棒测量"},{"_id":"6a5e78454cc76d93cba3b38f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble mieszkaniowe - Łóżka i materace E","test_object_en":"Domestic furniture - Beds and mattresses E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, próba stanowiskowa"],"technique_en":"Method: force and/or mass loading, bench test","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa","reference":"PN-EN 1725","norm_bases":["PN-EN 1725"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble mieszkaniowe - Łóżka i materace E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa PN-EN 1725 Meble mieszkaniowe - Lozka i materace E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, proba stanowiskowa PN-EN 1725","categories":["other"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Domestic furniture - Beds and mattresses E Stability Method: force and/or mass loading, bench test Range Range Range PN-EN 1725","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"稳定性 方法：加力和/或加质量载荷、台架试验 范围 范围 范围 PN-EN 1725","methodology_zh":"稳定性","technique_zh":"方法：加力和/或加质量载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b390","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble mieszkaniowe - Łóżka i materace E","test_object_en":"Domestic furniture - Beds and mattresses E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, próba stanowiskowa"],"technique_en":"Method: force and/or mass loading, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa","reference":"PN-EN 1725","norm_bases":["PN-EN 1725"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble mieszkaniowe - Łóżka i materace E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa PN-EN 1725 Meble mieszkaniowe - Lozka i materace E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, proba stanowiskowa PN-EN 1725","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Domestic furniture - Beds and mattresses E Strength of construction Method: force and/or mass loading, bench test strength of the product and its components, durability Range Range Range Range PN-EN 1725","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 PN-EN 1725","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b391","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie basenów pływackich, E","test_object_en":"Swimming pool equipment, E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 270) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 270) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","norm_bases":["PN-EN 13451-1 z wyłączeniem p. 4.8","PN-EN 13451-2","PN-EN 13451-3","PN-EN 13451-4","PN-EN 13451-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie basenów pływackich, E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6 Wyposazenie basenow plywackich, E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 13451-1 z wylaczeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool equipment, E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 270) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b392","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie basenów pływackich E","test_object_en":"Swimming pool equipment E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 3000) N;"},{"name":"Zakres","range":"(0 - 500) kg;"},{"name":"Zakres","range":"(0 - 270) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 3000) N;"},{"name":"Range","range":"(0 - 500) kg;"},{"name":"Range","range":"(0 - 270) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 3000) N;\nZakres (0 - 500) kg;\nZakres (0 - 270) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","norm_bases":["PN-EN 13451-1 z wyłączeniem p. 4.8","PN-EN 13451-2","PN-EN 13451-3","PN-EN 13451-4","PN-EN 13451-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie basenów pływackich E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 3000) N;\nZakres (0 - 500) kg;\nZakres (0 - 270) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6 Wyposazenie basenow plywackich E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 3000) N;\nZakres (0 - 500) kg;\nZakres (0 - 270) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 13451-1 z wylaczeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","categories":["other"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool equipment E Strength of construction Method: loading with force and/or mass, probe testing, bench test Range Range Range Range PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","parameters_zh":[{"name":"范围","range":"(0 - 3000) N;"},{"name":"范围","range":"(0 - 500) kg;"},{"name":"范围","range":"(0 - 270) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 范围 范围 范围 范围 PN-EN 13451-1 z wyłączeniem p. 4.8 | PN-EN 13451-2 | PN-EN 13451-3 | PN-EN 13451-4 | PN-EN 13451-6","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b393","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Materiały metaliczne i z tworzywa sztucznego E","test_object_en":"Metallic and plastic materials E","methodology":"Antypoślizgowość powierzchni","methodology_en":"Surface slip resistance","parameters":[{"name":"Zakres","range":"(0 - 45) °"}],"parameters_en":[{"name":"Range","range":"(0 - 45) °"}],"technique":"Metoda: próba stateczności na pochylni","techniques":["Metoda: próba stateczności na pochylni"],"technique_en":"Method: stability test on an inclined plane","computed":[],"computed_en":[],"activity":"Antypoślizgowość powierzchni\nZakres (0 - 45) °\nMetoda: próba stateczności na pochylni","reference":"PN-EN 13845 ;","norm_bases":["PN-EN 13845 ;"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały metaliczne i z tworzywa sztucznego E Antypoślizgowość powierzchni\nZakres (0 - 45) °\nMetoda: próba stateczności na pochylni PN-EN 13845 ; Materialy metaliczne i z tworzywa sztucznego E Antyposlizgowosc powierzchni\nZakres (0 - 45) °\nMetoda: proba statecznosci na pochylni PN-EN 13845 ;","categories":["materials"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metallic and plastic materials E Surface slip resistance Method: stability test on an inclined plane Range PN-EN 13845 ;","parameters_zh":[{"name":"范围","range":"(0 - 45) °"}],"search_zh":"范围 PN-EN 13845 ;"},{"_id":"6a5e78454cc76d93cba3b394","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Materiały eksploatacyjne do drukarek, kopiarek i urządzeń wielofunkcyjnych E","test_object_en":"Consumables for printers, copiers and multifunction devices E","methodology":"Wydajność","methodology_en":"Capacity","parameters":[],"parameters_en":[],"technique":"Metoda: wydruk stron testowych","techniques":["Metoda: wydruk stron testowych"],"technique_en":"Method: printing of test pages","computed":[],"computed_en":[],"activity":"Wydajność\nMetoda: wydruk stron testowych","reference":"ISO/IEC 19752 ISO/IEC 19798 ISO/IEC 24711 ISO/IEC 24712 ISO/IEC 29102 ISO/IEC 29103","norm_bases":["ISO/IEC 19752 ISO/IEC 19798 ISO/IEC 24711 ISO/IEC 24712 ISO/IEC 29102 ISO/IEC 29103"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały eksploatacyjne do drukarek, kopiarek i urządzeń wielofunkcyjnych E Wydajność\nMetoda: wydruk stron testowych ISO/IEC 19752 ISO/IEC 19798 ISO/IEC 24711 ISO/IEC 24712 ISO/IEC 29102 ISO/IEC 29103 Materialy eksploatacyjne do drukarek, kopiarek i urzadzen wielofunkcyjnych E Wydajnosc\nMetoda: wydruk stron testowych ISO/IEC 19752 ISO/IEC 19798 ISO/IEC 24711 ISO/IEC 24712 ISO/IEC 29102 ISO/IEC 29103","categories":["materials"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Consumables for printers, copiers and multifunction devices E Capacity Method: printing of test pages ISO/IEC 19752 ISO/IEC 19798 ISO/IEC 24711 ISO/IEC 24712 ISO/IEC 29102 ISO/IEC 29103"},{"_id":"6a5e78454cc76d93cba3b395","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie siłowni plenerowych E","test_object_en":"Outdoor gym equipment E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 16630","norm_bases":["PN-EN 16630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie siłowni plenerowych E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 16630 Wyposazenie silowni plenerowych E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 16630","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Outdoor gym equipment E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 16630","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 16630","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b396","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie siłowni plenerowych E","test_object_en":"Outdoor gym equipment E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 50000) N;"},{"name":"Zakres","range":"(0 - 2000) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 50000) N;"},{"name":"Range","range":"(0 - 2000) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 50000) N;\nZakres (0 - 2000) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 16630","norm_bases":["PN-EN 16630"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie siłowni plenerowych E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 50000) N;\nZakres (0 - 2000) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 16630 Wyposazenie silowni plenerowych E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 50000) N;\nZakres (0 - 2000) kg\nMetoda: obciazenie sila i/lub masa PN-EN 16630","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Outdoor gym equipment E Strength of construction Method: loading with force and/or mass Range Range PN-EN 16630","parameters_zh":[{"name":"范围","range":"(0 - 50000) N;"},{"name":"范围","range":"(0 - 2000) kg"}],"search_zh":"结构强度 方法：施加力和/或质量载荷 范围 范围 PN-EN 16630","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b397","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – siedziska użytkowane poza mieszkaniem E","test_object_en":"Furniture – non-domestic seating E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 16139","norm_bases":["PN-EN 16139"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – siedziska użytkowane poza mieszkaniem E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 16139 Meble – siedziska uzytkowane poza mieszkaniem E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 16139","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – non-domestic seating E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range Range PN-EN 16139","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家具 － 住宅以外使用的坐具 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 PN-EN 16139","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"家具 － 住宅以外使用的坐具 E"},{"_id":"6a5e78454cc76d93cba3b398","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – siedziska użytkowane poza mieszkaniem E","test_object_en":"Furniture – non-domestic seating E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 16139","norm_bases":["PN-EN 16139"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – siedziska użytkowane poza mieszkaniem E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 16139 Meble – siedziska uzytkowane poza mieszkaniem E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 16139","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – non-domestic seating E Stability Method: loading with force and/or mass Range Range PN-EN 16139","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"家具 － 住宅以外使用的坐具 E 稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 16139","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷","test_object_zh":"家具 － 住宅以外使用的坐具 E"},{"_id":"6a5e78454cc76d93cba3b399","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – siedziska użytkowane poza mieszkaniem E","test_object_en":"Furniture – non-domestic seating E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 16139","norm_bases":["PN-EN 16139"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – siedziska użytkowane poza mieszkaniem E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 16139 Meble – siedziska uzytkowane poza mieszkaniem E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 16139","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – non-domestic seating E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 16139","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"家具 － 住宅以外使用的坐具 E 几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 16139","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"家具 － 住宅以外使用的坐具 E"},{"_id":"6a5e78454cc76d93cba3b39a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble - siedziska mieszkaniowe E","test_object_en":"Furniture - domestic seating E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 12520","norm_bases":["PN-EN 12520"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble - siedziska mieszkaniowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 12520 Meble - siedziska mieszkaniowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 12520","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture - domestic seating E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range Range PN-EN 12520","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 PN-EN 12520","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b39b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble - siedziska mieszkaniowe E","test_object_en":"Furniture - domestic seating E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 12520","norm_bases":["PN-EN 12520"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble - siedziska mieszkaniowe E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 12520 Meble - siedziska mieszkaniowe E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 12520","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture - domestic seating E Stability Method: loading with force and/or mass Range Range PN-EN 12520","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 12520","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b39c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble - siedziska mieszkaniowe E","test_object_en":"Furniture - domestic seating E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 12520","norm_bases":["PN-EN 12520"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble - siedziska mieszkaniowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 12520 Meble - siedziska mieszkaniowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 12520","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture - domestic seating E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 12520","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 12520","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b39d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille opalane paliwami stałymi E","test_object_en":"Solid fuel fired barbecues E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1860-1","norm_bases":["PN-EN 1860-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille opalane paliwami stałymi E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1860-1 Grille opalane paliwami stalymi E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1860-1","categories":["petro"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuel fired barbecues E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1860-1","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"固体燃料烧烤炉 E 几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1860-1","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"固体燃料烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b39e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille opalane paliwami stałymi E","test_object_en":"Solid fuel fired barbecues E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 500) N;"},{"name":"Zakres","range":"(0 - 50) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 500) N;"},{"name":"Range","range":"(0 - 50) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 500) N;\nZakres (0 - 50) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1860-1","norm_bases":["PN-EN 1860-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille opalane paliwami stałymi E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 500) N;\nZakres (0 - 50) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1860-1 Grille opalane paliwami stalymi E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 500) N;\nZakres (0 - 50) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1860-1","categories":["petro"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuel fired barbecues E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range Range PN-EN 1860-1","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 500) N;"},{"name":"范围","range":"(0 - 50) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"固体燃料烧烤炉 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 PN-EN 1860-1","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"固体燃料烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b39f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille opalane paliwami stałymi E","test_object_en":"Solid fuel fired barbecues E","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(od -50 do 800) °C"}],"parameters_en":[{"name":"Range","range":"(od -50 do 800) °C"}],"technique":"Metoda: pomiar temperatury","techniques":["Metoda: pomiar temperatury"],"technique_en":"Method: temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do 800) °C\nMetoda: pomiar temperatury","reference":"PN-EN 1860-1","norm_bases":["PN-EN 1860-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille opalane paliwami stałymi E Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do 800) °C\nMetoda: pomiar temperatury PN-EN 1860-1 Grille opalane paliwami stalymi E Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (od -50 do 800) °C\nMetoda: pomiar temperatury PN-EN 1860-1","categories":["petro"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuel fired barbecues E Temperature emitted by various parts of the appliance Method: temperature measurement Range PN-EN 1860-1","parameters_zh":[{"name":"范围","range":"(od -50 do 800) °C"}],"search_zh":"固体燃料烧烤炉 E 设备各部件散发的温度 范围 PN-EN 1860-1","methodology_zh":"设备各部件散发的温度","test_object_zh":"固体燃料烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b3a0","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille opalane paliwami stałymi E","test_object_en":"Solid fuel fired barbecues E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 50) kg;"},{"name":"Zakres","range":"(0 - 45) °"}],"parameters_en":[{"name":"Range","range":"(0 - 50) kg;"},{"name":"Range","range":"(0 - 45) °"}],"technique":"Metoda: obciążenie masą i/lub momentem","techniques":["Metoda: obciążenie masą i/lub momentem"],"technique_en":"Method: loading with mass and/or moment","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 50) kg;\nZakres (0 - 45) °\nMetoda: obciążenie masą i/lub momentem","reference":"PN-EN 1860-1","norm_bases":["PN-EN 1860-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille opalane paliwami stałymi E Stateczność\nZakres:\nZakres (0 - 50) kg;\nZakres (0 - 45) °\nMetoda: obciążenie masą i/lub momentem PN-EN 1860-1 Grille opalane paliwami stalymi E Statecznosc\nZakres:\nZakres (0 - 50) kg;\nZakres (0 - 45) °\nMetoda: obciazenie masa i/lub momentem PN-EN 1860-1","categories":["petro"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuel fired barbecues E Stability Method: loading with mass and/or moment Range Range PN-EN 1860-1","parameters_zh":[{"name":"范围","range":"(0 - 50) kg;"},{"name":"范围","range":"(0 - 45) °"}],"search_zh":"固体燃料烧烤炉 E 稳定性 范围 范围 PN-EN 1860-1","methodology_zh":"稳定性","test_object_zh":"固体燃料烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b3a1","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Podpałki do rozpalania stosowane w urządzeniach do grillowania E","test_object_en":"Firelighters used in barbecue appliances E","methodology":"Konsystencja podpałek","methodology_en":"Consistency of firelighters","parameters":[{"name":"Zakres","range":"(0 - 30) min."}],"parameters_en":[{"name":"Range","range":"(0 - 30) min."}],"technique":"Metoda: pomiar czasu","techniques":["Metoda: pomiar czasu"],"technique_en":"Method: time measurement","computed":[],"computed_en":[],"activity":"Konsystencja podpałek\nZakres (0 - 30) min.\nMetoda: pomiar czasu","reference":"PN-EN 1860-3","norm_bases":["PN-EN 1860-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podpałki do rozpalania stosowane w urządzeniach do grillowania E Konsystencja podpałek\nZakres (0 - 30) min.\nMetoda: pomiar czasu PN-EN 1860-3 Podpalki do rozpalania stosowane w urzadzeniach do grillowania E Konsystencja podpalek\nZakres (0 - 30) min.\nMetoda: pomiar czasu PN-EN 1860-3","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Firelighters used in barbecue appliances E Consistency of firelighters Method: time measurement Range PN-EN 1860-3","parameters_zh":[{"name":"范围","range":"(0 - 30) min."}],"search_zh":"方法：时间测量 范围 PN-EN 1860-3","technique_zh":"方法：时间测量"},{"_id":"6a5e78454cc76d93cba3b3a2","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Podpałki do rozpalania stosowane w urządzeniach do grillowania E","test_object_en":"Firelighters used in barbecue appliances E","methodology":"Charakterystyka spalania","methodology_en":"Combustion characteristics","parameters":[{"name":"Zakres","range":"(0 - 60) min."}],"parameters_en":[{"name":"Range","range":"(0 - 60) min."}],"technique":"Metoda: pomiar czasu","techniques":["Metoda: pomiar czasu"],"technique_en":"Method: time measurement","computed":[],"computed_en":[],"activity":"Charakterystyka spalania\nZakres (0 - 60) min.\nMetoda: pomiar czasu","reference":"PN-EN 1860-3","norm_bases":["PN-EN 1860-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podpałki do rozpalania stosowane w urządzeniach do grillowania E Charakterystyka spalania\nZakres (0 - 60) min.\nMetoda: pomiar czasu PN-EN 1860-3 Podpalki do rozpalania stosowane w urzadzeniach do grillowania E Charakterystyka spalania\nZakres (0 - 60) min.\nMetoda: pomiar czasu PN-EN 1860-3","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Firelighters used in barbecue appliances E Combustion characteristics Method: time measurement Range PN-EN 1860-3","parameters_zh":[{"name":"范围","range":"(0 - 60) min."}],"search_zh":"方法：时间测量 范围 PN-EN 1860-3","technique_zh":"方法：时间测量"},{"_id":"6a5e78454cc76d93cba3b3a3","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Podpałki do rozpalania stosowane w urządzeniach do grillowania E","test_object_en":"Firelighters used in barbecue appliances E","methodology":"Wytrzymałość konstrukcji opakowań podpałek płynnych, Odporność na podwyższoną temperaturę i wilgotność opakowań podpałek stałych","methodology_en":"Structural strength of packaging for liquid firelighters, Resistance to elevated temperature and humidity of packaging for solid firelighters","parameters":[],"parameters_en":[],"technique":"Metoda: obciążenie masą, próba stanowiskowa, przetrzymywanie w komorze klimatycznej","techniques":["Metoda: obciążenie masą, próba stanowiskowa, przetrzymywanie w komorze klimatycznej"],"technique_en":"Method: loading with mass, bench test, holding in a climatic chamber","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji opakowań podpałek płynnych, Odporność na podwyższoną temperaturę i wilgotność opakowań podpałek stałych\nMetoda: obciążenie masą, próba stanowiskowa, przetrzymywanie w komorze klimatycznej","reference":"PN-EN 1860-3","norm_bases":["PN-EN 1860-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Podpałki do rozpalania stosowane w urządzeniach do grillowania E Wytrzymałość konstrukcji opakowań podpałek płynnych, Odporność na podwyższoną temperaturę i wilgotność opakowań podpałek stałych\nMetoda: obciążenie masą, próba stanowiskowa, przetrzymywanie w komorze klimatycznej PN-EN 1860-3 Podpalki do rozpalania stosowane w urzadzeniach do grillowania E Wytrzymalosc konstrukcji opakowan podpalek plynnych, Odpornosc na podwyzszona temperature i wilgotnosc opakowan podpalek stalych\nMetoda: obciazenie masa, proba stanowiskowa, przetrzymywanie w komorze klimatycznej PN-EN 1860-3","categories":["other"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Firelighters used in barbecue appliances E Structural strength of packaging for liquid firelighters, Resistance to elevated temperature and humidity of packaging for solid firelighters Method: loading with mass, bench test, holding in a climatic chamber PN-EN 1860-3"},{"_id":"6a5e78454cc76d93cba3b3a4","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille jednorazowego użytku E","test_object_en":"Disposable barbecues E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1860-4","norm_bases":["PN-EN 1860-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille jednorazowego użytku E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1860-4 Grille jednorazowego uzytku E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1860-4","categories":["other"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disposable barbecues E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1860-4","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"一次性烧烤炉 E 几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1860-4","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"一次性烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b3a5","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille jednorazowego użytku E","test_object_en":"Disposable barbecues E","methodology":"Charakterystyka spalania","methodology_en":"Combustion characteristics","parameters":[{"name":"Zakres","range":"(0- 120) min"}],"parameters_en":[{"name":"Range","range":"(0- 120) min"}],"technique":"Metoda: pomiar czasu","techniques":["Metoda: pomiar czasu"],"technique_en":"Method: time measurement","computed":[],"computed_en":[],"activity":"Charakterystyka spalania\nZakres (0- 120) min\nMetoda: pomiar czasu","reference":"PN-EN 1860-4","norm_bases":["PN-EN 1860-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille jednorazowego użytku E Charakterystyka spalania\nZakres (0- 120) min\nMetoda: pomiar czasu PN-EN 1860-4 Grille jednorazowego uzytku E Charakterystyka spalania\nZakres (0- 120) min\nMetoda: pomiar czasu PN-EN 1860-4","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disposable barbecues E Combustion characteristics Method: time measurement Range PN-EN 1860-4","parameters_zh":[{"name":"范围","range":"(0- 120) min"}],"search_zh":"一次性烧烤炉 E 方法：时间测量 范围 PN-EN 1860-4","technique_zh":"方法：时间测量","test_object_zh":"一次性烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b3a6","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille jednorazowego użytku E","test_object_en":"Disposable barbecues E","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(od -50 do 800)°C"}],"parameters_en":[{"name":"Range","range":"(od -50 do 800)°C"}],"technique":"Metoda: pomiar temperatury","techniques":["Metoda: pomiar temperatury"],"technique_en":"Method: temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do 800)°C\nMetoda: pomiar temperatury","reference":"PN-EN 1860-4","norm_bases":["PN-EN 1860-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille jednorazowego użytku E Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do 800)°C\nMetoda: pomiar temperatury PN-EN 1860-4 Grille jednorazowego uzytku E Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (od -50 do 800)°C\nMetoda: pomiar temperatury PN-EN 1860-4","categories":["other"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disposable barbecues E Temperature emitted by various parts of the appliance Method: temperature measurement Range PN-EN 1860-4","parameters_zh":[{"name":"范围","range":"(od -50 do 800)°C"}],"search_zh":"一次性烧烤炉 E 设备各部件散发的温度 范围 PN-EN 1860-4","methodology_zh":"设备各部件散发的温度","test_object_zh":"一次性烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b3a7","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille jednorazowego użytku E","test_object_en":"Disposable barbecues E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 50) kg;"},{"name":"Zakres","range":"(0 - 45) °"}],"parameters_en":[{"name":"Range","range":"(0 - 50) kg;"},{"name":"Range","range":"(0 - 45) °"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem"],"technique_en":"Method: force and/or mass and/or torque loading","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 50) kg;\nZakres (0 - 45) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem","reference":"PN-EN 1860-4","norm_bases":["PN-EN 1860-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille jednorazowego użytku E Stateczność\nZakres:\nZakres (0 - 50) kg;\nZakres (0 - 45) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem PN-EN 1860-4 Grille jednorazowego uzytku E Statecznosc\nZakres:\nZakres (0 - 50) kg;\nZakres (0 - 45) °\nMetoda: obciazenie sila i/lub masa i/lub momentem PN-EN 1860-4","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disposable barbecues E Stability Method: force and/or mass and/or torque loading Range Range PN-EN 1860-4","parameters_zh":[{"name":"范围","range":"(0 - 50) kg;"},{"name":"范围","range":"(0 - 45) °"}],"search_zh":"一次性烧烤炉 E 稳定性 范围 范围 PN-EN 1860-4","methodology_zh":"稳定性","test_object_zh":"一次性烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b3a8","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Grille jednorazowego użytku E","test_object_en":"Disposable barbecues E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 500) N;"},{"name":"Zakres","range":"(0 - 50) kg;"},{"name":"Zakres","range":"(0 - 200) Nm;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 1000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 500) N;"},{"name":"Range","range":"(0 - 50) kg;"},{"name":"Range","range":"(0 - 200) Nm;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 1000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 500) N;\nZakres (0 - 50) kg;\nZakres (0 - 200) Nm;\nZakres (0 - 360) °;\nZakres (0 - 1000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1860-4","norm_bases":["PN-EN 1860-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Grille jednorazowego użytku E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 500) N;\nZakres (0 - 50) kg;\nZakres (0 - 200) Nm;\nZakres (0 - 360) °;\nZakres (0 - 1000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1860-4 Grille jednorazowego uzytku E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 500) N;\nZakres (0 - 50) kg;\nZakres (0 - 200) Nm;\nZakres (0 - 360) °;\nZakres (0 - 1000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1860-4","categories":["other"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Disposable barbecues E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range Range Range PN-EN 1860-4","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 500) N;"},{"name":"范围","range":"(0 - 50) kg;"},{"name":"范围","range":"(0 - 200) Nm;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 1000) mm"}],"search_zh":"一次性烧烤炉 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 范围 PN-EN 1860-4","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"一次性烧烤炉 E"},{"_id":"6a5e78454cc76d93cba3b3a9","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia parkour E","test_object_en":"Parkour equipment E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 16899","norm_bases":["PN-EN 16899"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia parkour E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 16899 Urzadzenia parkour E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 16899","categories":["other"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Parkour equipment E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 16899","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 16899","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3aa","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia parkour E","test_object_en":"Parkour equipment E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba uderzenia bijakiem","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba uderzenia bijakiem"],"technique_en":"Method: loading with force and/or mass, testing with a probe, impact test with a striker","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba uderzenia bijakiem","reference":"PN-EN 16899","norm_bases":["PN-EN 16899"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia parkour E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba uderzenia bijakiem PN-EN 16899 Urzadzenia parkour E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba uderzenia bijakiem PN-EN 16899","categories":["other"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Parkour equipment E Strength of construction Method: loading with force and/or mass, testing with a probe, impact test with a striker Range Range Range Range PN-EN 16899","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 范围 范围 范围 范围 PN-EN 16899","methodology_zh":"结构强度"},{"_id":"6a5e78454cc76d93cba3b3ab","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Okucia meblowe E","test_object_en":"Furniture fittings E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, próba stanowiskowa"],"technique_en":"Method: force and/or mass loading, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa","reference":"PN-EN 15338","norm_bases":["PN-EN 15338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia meblowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa PN-EN 15338 Okucia meblowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, proba stanowiskowa PN-EN 15338","categories":["other"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture fittings E Strength of construction Method: force and/or mass loading, bench test strength of the product and its components, durability Range Range Range PN-EN 15338","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 15338","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b3ac","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Okucia meblowe E","test_object_en":"Furniture fittings E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN 15338","norm_bases":["PN-EN 15338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia meblowe E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni PN-EN 15338 Okucia meblowe E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni PN-EN 15338","categories":["other"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture fittings E Geometric dimensions Method: direct measurement Range PN-EN 15338","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量 范围 PN-EN 15338","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b3ad","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Okucia meblowe E","test_object_en":"Furniture fittings E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":"Metoda: CH, AHT, AT","techniques":["Metoda: CH, AHT, AT"],"technique_en":"Method: CH, AHT, AT","computed":[],"computed_en":[],"activity":"Odporność na korozję\nMetoda: CH, AHT, AT","reference":"PN-EN 15338","norm_bases":["PN-EN 15338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Okucia meblowe E Odporność na korozję\nMetoda: CH, AHT, AT PN-EN 15338 Okucia meblowe E Odpornosc na korozje\nMetoda: CH, AHT, AT PN-EN 15338","categories":["other"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture fittings E Corrosion resistance Method: CH, AHT, AT PN-EN 15338","methodology_zh":"耐腐蚀性","search_zh":"耐腐蚀性 PN-EN 15338"},{"_id":"6a5e78454cc76d93cba3b3ae","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły mieszkaniowe E","test_object_en":"Furniture – Domestic tables E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenia siłą i/lub masą","techniques":["Metoda: obciążenia siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenia siłą i/lub masą","reference":"PN-EN 12521","norm_bases":["PN-EN 12521"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły mieszkaniowe E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenia siłą i/lub masą PN-EN 12521 Meble – Stoly mieszkaniowe E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenia sila i/lub masa PN-EN 12521","categories":["other"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Domestic tables E Stability Method: loading with force and/or mass Range Range PN-EN 12521","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 范围 范围 PN-EN 12521","methodology_zh":"稳定性"},{"_id":"6a5e78454cc76d93cba3b3af","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły mieszkaniowe E","test_object_en":"Furniture – Domestic tables E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 12521","norm_bases":["PN-EN 12521"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły mieszkaniowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 12521 Meble – Stoly mieszkaniowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 12521","categories":["other"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Domestic tables E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range PN-EN 12521","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 12521","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b3b0","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły mieszkaniowe E","test_object_en":"Furniture – Domestic tables E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 12521","norm_bases":["PN-EN 12521"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły mieszkaniowe E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 12521 Meble – Stoly mieszkaniowe E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 12521","categories":["other"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Domestic tables E Geometric dimensions Method: direct measurement, probe testing Range PN-EN 12521","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 PN-EN 12521","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3b1","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły użytkowane poza mieszkaniem E","test_object_en":"Furniture – Non-domestic tables E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 15372","norm_bases":["PN-EN 15372"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły użytkowane poza mieszkaniem E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 15372 Meble – Stoly uzytkowane poza mieszkaniem E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 15372","categories":["other"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Non-domestic tables E Stability Method: loading with force and/or mass Range Range PN-EN 15372","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 15372","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b3b2","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły użytkowane poza mieszkaniem E","test_object_en":"Furniture – Non-domestic tables E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 15372","norm_bases":["PN-EN 15372"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły użytkowane poza mieszkaniem E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 15372 Meble – Stoly uzytkowane poza mieszkaniem E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 15372","categories":["other"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Non-domestic tables E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range PN-EN 15372","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 15372","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b3b3","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły użytkowane poza mieszkaniem E","test_object_en":"Furniture – Non-domestic tables E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 15372","norm_bases":["PN-EN 15372"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły użytkowane poza mieszkaniem E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 15372 Meble – Stoly uzytkowane poza mieszkaniem E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 15372","categories":["other"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Non-domestic tables E Geometric dimensions Method: direct measurement, probe testing Range PN-EN 15372","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 PN-EN 15372","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3b4","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Drabiny strychowe E","test_object_en":"Loft ladders E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 14975","norm_bases":["PN-EN 14975"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drabiny strychowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 14975 Drabiny strychowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 14975","categories":["other"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Loft ladders E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 14975","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 14975","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3b5","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Drabiny strychowe E","test_object_en":"Loft ladders E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość,"},{"name":"skręcanie"},{"name":"Zakres","range":"(0 - 3000) N;"},{"name":"Zakres","range":"(0 - 300) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 1000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability,"},{"name":"torsion"},{"name":"Range","range":"(0 - 3000) N;"},{"name":"Range","range":"(0 - 300) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 1000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 3000) N;\nZakres (0 - 300) kg;\nZakres (0 - 360) °;\nZakres (0 - 1000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 14975","norm_bases":["PN-EN 14975"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Drabiny strychowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 3000) N;\nZakres (0 - 300) kg;\nZakres (0 - 360) °;\nZakres (0 - 1000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 14975 Drabiny strychowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc,\nskrecanie\nZakres (0 - 3000) N;\nZakres (0 - 300) kg;\nZakres (0 - 360) °;\nZakres (0 - 1000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 14975","categories":["other"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Loft ladders E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability, torsion Range Range Range Range PN-EN 14975","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性，"},{"name":"扭转"},{"name":"范围","range":"(0 - 3000) N;"},{"name":"范围","range":"(0 - 300) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 1000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性， 扭转 范围 范围 范围 范围 PN-EN 14975","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b3b6","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – siedziska szeregowe E","test_object_en":"Furniture – beam seating E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 12727","norm_bases":["PN-EN 12727"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – siedziska szeregowe E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 12727 Meble – siedziska szeregowe E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 12727","categories":["other"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – beam seating E Geometric dimensions Method: direct measurement, probe testing Range PN-EN 12727","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 PN-EN 12727","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3b7","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – siedziska szeregowe E","test_object_en":"Furniture – beam seating E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 12727","norm_bases":["PN-EN 12727"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – siedziska szeregowe E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 12727 Meble – siedziska szeregowe E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 12727","categories":["other"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – beam seating E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range Range PN-EN 12727","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 范围 PN-EN 12727","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b3b8","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw − kolejki linowe E","test_object_en":"Playground equipment − cableways E","methodology":"Amortyzacja uderzeń siedzisk huśtawki","methodology_en":"Impact attenuation of swing seats","parameters":[{"name":"Zakres","range":"(0 - 200) g;"},{"name":"Zakres","range":"(0 - 1000) N/cm2"}],"parameters_en":[{"name":"Range","range":"(0 - 200) g;"},{"name":"Range","range":"(0 - 1000) N/cm2"}],"technique":"Metoda: badanie modelem głowy","techniques":["Metoda: badanie modelem głowy"],"technique_en":"Method: headform test","computed":[],"computed_en":[],"activity":"Amortyzacja uderzeń siedzisk huśtawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem głowy","reference":"PN-EN 1176-4","norm_bases":["PN-EN 1176-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw − kolejki linowe E Amortyzacja uderzeń siedzisk huśtawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem głowy PN-EN 1176-4 Wyposazenie placow zabaw − kolejki linowe E Amortyzacja uderzen siedzisk hustawki\nZakres:\nZakres (0 - 200) g;\nZakres (0 - 1000) N/cm2\nMetoda: badanie modelem glowy PN-EN 1176-4","categories":["other"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment − cableways E Impact attenuation of swing seats Method: headform test Range Range PN-EN 1176-4","parameters_zh":[{"name":"范围","range":"(0 - 200) g;"},{"name":"范围","range":"(0 - 1000) N/cm2"}],"search_zh":"方法：头部模型试验 范围 范围 PN-EN 1176-4","technique_zh":"方法：头部模型试验"},{"_id":"6a5e78454cc76d93cba3b3b9","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw − kolejki linowe E","test_object_en":"Playground equipment − cableways E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 1176-4","norm_bases":["PN-EN 1176-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw − kolejki linowe E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą PN-EN 1176-4 Wyposazenie placow zabaw − kolejki linowe E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa PN-EN 1176-4","categories":["other"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment − cableways E Strength of construction Method: loading with force and/or mass Range Range PN-EN 1176-4","parameters_zh":[{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷 范围 范围 PN-EN 1176-4","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b3ba","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyposażenie placów zabaw − kolejki linowe E","test_object_en":"Playground equipment − cableways E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1176-4","norm_bases":["PN-EN 1176-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie placów zabaw − kolejki linowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1176-4 Wyposazenie placow zabaw − kolejki linowe E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1176-4","categories":["other"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Playground equipment − cableways E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1176-4","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1176-4","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3bb","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Grubość powłoki niemagnetycznej na podłożu Fe","methodology_en":"Thickness of the non-magnetic coating on an Fe substrate","parameters":[{"name":"Zakres","range":"(0 - 800) μm"}],"parameters_en":[{"name":"Range","range":"(0 - 800) μm"}],"technique":"Metoda: magnetyczna","techniques":["Metoda: magnetyczna"],"technique_en":"Method: magnetic","computed":[],"computed_en":[],"activity":"Grubość powłoki niemagnetycznej na podłożu Fe\nZakres (0 - 800) μm\nMetoda: magnetyczna","reference":"PN-EN ISO 2178","norm_bases":["PN-EN ISO 2178"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Grubość powłoki niemagnetycznej na podłożu Fe\nZakres (0 - 800) μm\nMetoda: magnetyczna PN-EN ISO 2178 Powloki E Grubosc powloki niemagnetycznej na podlozu Fe\nZakres (0 - 800) μm\nMetoda: magnetyczna PN-EN ISO 2178","categories":["other"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Coatings E Thickness of the non-magnetic coating on an Fe substrate Method: magnetic Range PN-EN ISO 2178","parameters_zh":[{"name":"范围","range":"(0 - 800) μm"}],"search_zh":"涂层 E 范围 PN-EN ISO 2178","test_object_zh":"涂层 E"},{"_id":"6a5e78454cc76d93cba3b3bc","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Powłoki E","test_object_en":"Coatings E","methodology":"Grubość powłoki nieprzewodzącej na podłożu N-Fe","methodology_en":"Thickness of the non-conductive coating on an N-Fe substrate","parameters":[{"name":"Zakres","range":"(0 - 800) μm"}],"parameters_en":[{"name":"Range","range":"(0 - 800) μm"}],"technique":"Metoda: prądów wirowych","techniques":["Metoda: prądów wirowych"],"technique_en":"Method: eddy currents","computed":[],"computed_en":[],"activity":"Grubość powłoki nieprzewodzącej na podłożu N-Fe\nZakres (0 - 800) μm\nMetoda: prądów wirowych","reference":"PN-EN ISO 2360","norm_bases":["PN-EN ISO 2360"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powłoki E Grubość powłoki nieprzewodzącej na podłożu N-Fe\nZakres (0 - 800) μm\nMetoda: prądów wirowych PN-EN ISO 2360 Powloki E Grubosc powloki nieprzewodzacej na podlozu N-Fe\nZakres (0 - 800) μm\nMetoda: pradow wirowych PN-EN ISO 2360","categories":["other"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Coatings E Thickness of the non-conductive coating on an N-Fe substrate Method: eddy currents Range PN-EN ISO 2360","parameters_zh":[{"name":"范围","range":"(0 - 800) μm"}],"search_zh":"涂层 E 范围 PN-EN ISO 2360","test_object_zh":"涂层 E"},{"_id":"6a5e78454cc76d93cba3b3bd","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E","test_object_en":"Finished products, subassemblies, metals, metal alloys and their coatings E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na korozję","reference":"PN-EN ISO 9227 | PN-EN 60068-2-11","norm_bases":["PN-EN ISO 9227","PN-EN 60068-2-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E Odporność na korozję PN-EN ISO 9227 | PN-EN 60068-2-11 Gotowe wyroby, podzespoly, metale, stopy metali i ich powloki E Odpornosc na korozje PN-EN ISO 9227 | PN-EN 60068-2-11","categories":["materials"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Finished products, subassemblies, metals, metal alloys and their coatings E Corrosion resistance PN-EN ISO 9227 | PN-EN 60068-2-11","methodology_zh":"耐腐蚀性","search_zh":"成品、组件、金属、合金及其涂层 E 耐腐蚀性 PN-EN ISO 9227 | PN-EN 60068-2-11","test_object_zh":"成品、组件、金属、合金及其涂层 E"},{"_id":"6a5e78454cc76d93cba3b3be","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E","test_object_en":"Finished products, subassemblies, metals, metal alloys and their coatings E","methodology":"Odporność na wilgoć","methodology_en":"Resistance to moisture","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wilgoć","reference":"PN-EN ISO 6270-2","norm_bases":["PN-EN ISO 6270-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E Odporność na wilgoć PN-EN ISO 6270-2 Gotowe wyroby, podzespoly, metale, stopy metali i ich powloki E Odpornosc na wilgoc PN-EN ISO 6270-2","categories":["materials"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Finished products, subassemblies, metals, metal alloys and their coatings E Resistance to moisture PN-EN ISO 6270-2","methodology_zh":"耐潮湿性","search_zh":"成品、组件、金属、合金及其涂层 E 耐潮湿性 PN-EN ISO 6270-2","test_object_zh":"成品、组件、金属、合金及其涂层 E"},{"_id":"6a5e78454cc76d93cba3b3bf","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E","test_object_en":"Finished products, subassemblies, metals, metal alloys and their coatings E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 1000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 1000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 1000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN ISO 10289","norm_bases":["PN-EN ISO 10289"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E Wymiary geometryczne\nZakres (0 - 1000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN ISO 10289 Gotowe wyroby, podzespoly, metale, stopy metali i ich powloki E Wymiary geometryczne\nZakres (0 - 1000) mm\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN ISO 10289","categories":["materials"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Finished products, subassemblies, metals, metal alloys and their coatings E Geometric dimensions Method: direct measurement, probe testing Range PN-EN ISO 10289","parameters_zh":[{"name":"范围","range":"(0 - 1000) mm"}],"search_zh":"成品、组件、金属、合金及其涂层 E 几何尺寸 方法：直接测量、探头检测 范围 PN-EN ISO 10289","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"成品、组件、金属、合金及其涂层 E"},{"_id":"6a5e78454cc76d93cba3b3c0","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E","test_object_en":"Finished products, subassemblies, metals, metal alloys and their coatings E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 1000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 1000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 1000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1670","norm_bases":["PN-EN 1670"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gotowe wyroby, podzespoły, metale, stopy metali i ich powłoki E Wymiary geometryczne\nZakres (0 - 1000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1670 Gotowe wyroby, podzespoly, metale, stopy metali i ich powloki E Wymiary geometryczne\nZakres (0 - 1000) mm\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1670","categories":["materials"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Finished products, subassemblies, metals, metal alloys and their coatings E Geometric dimensions Method: direct measurement, probe testing Range PN-EN 1670","parameters_zh":[{"name":"范围","range":"(0 - 1000) mm"}],"search_zh":"成品、组件、金属、合金及其涂层 E 几何尺寸 方法：直接测量、探头检测 范围 PN-EN 1670","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"成品、组件、金属、合金及其涂层 E"},{"_id":"6a5e78454cc76d93cba3b3c1","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Pomoce do kąpieli E","test_object_en":"Child care articles – Bathing aids E","methodology":"Masa wyrobu i jego elementów","methodology_en":"Mass of the product and its components","parameters":[{"name":"Zakres","range":"(0 - 150) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 150) kg"}],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"technique_en":"Method: gravimetric","computed":[],"computed_en":[],"activity":"Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa","reference":"PN-EN 17022","norm_bases":["PN-EN 17022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Pomoce do kąpieli E Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 17022 Artykuly dla dzieci – Pomoce do kapieli E Masa wyrobu i jego elementow\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 17022","categories":["other"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bathing aids E Mass of the product and its components Method: gravimetric Range PN-EN 17022","parameters_zh":[{"name":"范围","range":"(0 - 150) kg"}],"search_zh":"儿童用品 － 洗浴辅助用具 E 制品及其部件的质量 方法：重量法 范围 PN-EN 17022","technique_zh":"方法：重量法","methodology_zh":"制品及其部件的质量","test_object_zh":"儿童用品 － 洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c2","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Pomoce do kąpieli E","test_object_en":"Child care articles – Bathing aids E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"},{"name":"Zakres","range":"(0 - 800) μm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"},{"name":"Range","range":"(0 - 800) μm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna"],"technique_en":"Method: direct measurement, probe test, magnetic method","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna","reference":"PN-EN 17022","norm_bases":["PN-EN 17022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Pomoce do kąpieli E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna PN-EN 17022 Artykuly dla dzieci – Pomoce do kapieli E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezposredni, badanie probnikiem, metoda magnetyczna PN-EN 17022","categories":["other"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bathing aids E Geometric dimensions Method: direct measurement, probe test, magnetic method Range Range Range PN-EN 17022","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"},{"name":"范围","range":"(0 - 800) μm"}],"search_zh":"儿童用品 － 洗浴辅助用具 E 几何尺寸 范围 范围 范围 PN-EN 17022","methodology_zh":"几何尺寸","test_object_zh":"儿童用品 － 洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c3","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Pomoce do kąpieli E","test_object_en":"Child care articles – Bathing aids E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"odporność na moczenie"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 11) Nm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"resistance to soaking"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 11) Nm"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia"],"technique_en":"Method: force and/or mass and/or torque loading, probe test, bench test, soaking test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nodporność na moczenie\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia","reference":"PN-EN 17022","norm_bases":["PN-EN 17022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Pomoce do kąpieli E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nodporność na moczenie\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia PN-EN 17022 Artykuly dla dzieci – Pomoce do kapieli E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\nodpornosc na moczenie\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciazenie sila i/lub masa i/lub momentem, badanie probnikiem, proba stanowiskowa, proba moczenia PN-EN 17022","categories":["other"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bathing aids E Strength of construction Method: force and/or mass and/or torque loading, probe test, bench test, soaking test strength of the product and its components, resistance to soaking Range Range Range Range Range PN-EN 17022","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐浸湿性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 11) Nm"}],"search_zh":"儿童用品 － 洗浴辅助用具 E 结构强度 制品及其部件的强度， 耐浸湿性 范围 范围 范围 范围 范围 PN-EN 17022","methodology_zh":"结构强度","test_object_zh":"儿童用品 － 洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c4","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Pomoce do kąpieli E","test_object_en":"Child care articles – Bathing aids E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, próba stanowiskowa"],"technique_en":"Method: force and/or mass loading, bench test","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 360) °\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa","reference":"PN-EN 17022","norm_bases":["PN-EN 17022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Pomoce do kąpieli E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 360) °\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa PN-EN 17022 Artykuly dla dzieci – Pomoce do kapieli E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 360) °\nMetoda: obciazenie sila i/lub masa, proba stanowiskowa PN-EN 17022","categories":["other"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bathing aids E Stability Method: force and/or mass loading, bench test Range Range Range PN-EN 17022","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"儿童用品 － 洗浴辅助用具 E 稳定性 方法：加力和/或加质量载荷、台架试验 范围 范围 范围 PN-EN 17022","methodology_zh":"稳定性","technique_zh":"方法：加力和/或加质量载荷、台架试验","test_object_zh":"儿童用品 － 洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c5","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E","test_object_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E","methodology":"Masa wyrobu i jego elementów","methodology_en":"Mass of the product and its components","parameters":[{"name":"Zakres","range":"(0 - 150) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 150) kg"}],"technique":"Metoda: wagowa","techniques":["Metoda: wagowa"],"technique_en":"Method: gravimetric","computed":[],"computed_en":[],"activity":"Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa","reference":"PN-EN 17072","norm_bases":["PN-EN 17072"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E Masa wyrobu i jego elementów\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 17072 Artykuly dla dzieci – Wanienki do kapieli, stojaki oraz pomoce do kapieli, ktore nie sa stosowane jako wolnostojace E Masa wyrobu i jego elementow\nZakres (0 - 150) kg\nMetoda: wagowa PN-EN 17072","categories":["other"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E Mass of the product and its components Method: gravimetric Range PN-EN 17072","parameters_zh":[{"name":"范围","range":"(0 - 150) kg"}],"search_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E 制品及其部件的质量 方法：重量法 范围 PN-EN 17072","technique_zh":"方法：重量法","methodology_zh":"制品及其部件的质量","test_object_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c6","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E","test_object_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"},{"name":"Zakres","range":"(0 - 800) μm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"},{"name":"Range","range":"(0 - 800) μm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna"],"technique_en":"Method: direct measurement, probe test, magnetic method","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna","reference":"PN-EN 17072","norm_bases":["PN-EN 17072"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezpośredni, badanie próbnikiem, metoda magnetyczna PN-EN 17072 Artykuly dla dzieci – Wanienki do kapieli, stojaki oraz pomoce do kapieli, ktore nie sa stosowane jako wolnostojace E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nZakres (0 - 800) μm\nMetoda: pomiar bezposredni, badanie probnikiem, metoda magnetyczna PN-EN 17072","categories":["other"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E Geometric dimensions Method: direct measurement, probe test, magnetic method Range Range Range PN-EN 17072","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"},{"name":"范围","range":"(0 - 800) μm"}],"search_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E 几何尺寸 范围 范围 范围 PN-EN 17072","methodology_zh":"几何尺寸","test_object_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c7","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E","test_object_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E","methodology":"Stabilność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 30) °;"},{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 30) °;"},{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, próba stanowiskowa"],"technique_en":"Method: force and/or mass loading, bench test","computed":[],"computed_en":[],"activity":"Stabilność\nZakres:\nZakres (0 - 30) °;\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa","reference":"PN-EN 17072","norm_bases":["PN-EN 17072"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E Stabilność\nZakres:\nZakres (0 - 30) °;\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą, próba stanowiskowa PN-EN 17072 Artykuly dla dzieci – Wanienki do kapieli, stojaki oraz pomoce do kapieli, ktore nie sa stosowane jako wolnostojace E Stabilnosc\nZakres:\nZakres (0 - 30) °;\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa, proba stanowiskowa PN-EN 17072","categories":["other"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E Stability Method: force and/or mass loading, bench test Range Range Range PN-EN 17072","parameters_zh":[{"name":"范围","range":"(0 - 30) °;"},{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E 稳定性 方法：加力和/或加质量载荷、台架试验 范围 范围 范围 PN-EN 17072","methodology_zh":"稳定性","technique_zh":"方法：加力和/或加质量载荷、台架试验","test_object_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c8","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E","test_object_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"odporność na moczenie"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 11) Nm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"resistance to soaking"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 11) Nm"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia"],"technique_en":"Method: force and/or mass and/or torque loading, probe test, bench test, soaking test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nodporność na moczenie\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia","reference":"PN-EN 17072","norm_bases":["PN-EN 17072"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wanienki do kąpieli, stojaki oraz pomoce do kąpieli, które nie są stosowane jako wolnostojące E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\nodporność na moczenie\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa, próba moczenia PN-EN 17072 Artykuly dla dzieci – Wanienki do kapieli, stojaki oraz pomoce do kapieli, ktore nie sa stosowane jako wolnostojace E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\nodpornosc na moczenie\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 11) Nm\nMetoda: obciazenie sila i/lub masa i/lub momentem, badanie probnikiem, proba stanowiskowa, proba moczenia PN-EN 17072","categories":["other"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Child care articles – Bath tubs, stands and non-free standing bathing aids E Strength of construction Method: force and/or mass and/or torque loading, probe test, bench test, soaking test strength of the product and its components, resistance to soaking Range Range Range Range Range PN-EN 17072","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐浸湿性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 11) Nm"}],"search_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E 结构强度 制品及其部件的强度， 耐浸湿性 范围 范围 范围 范围 范围 PN-EN 17072","methodology_zh":"结构强度","test_object_zh":"儿童用品 － 浴盆、支架及非独立式洗浴辅助用具 E"},{"_id":"6a5e78454cc76d93cba3b3c9","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Gondole i stojaki – Wymagania bezpieczeństwa i metody badań E","test_object_en":"Childcare articles – Carry cots and stands – Safety requirements and test methods E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1466","norm_bases":["PN-EN 1466"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Gondole i stojaki – Wymagania bezpieczeństwa i metody badań E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1466 Artykuly dla dzieci – Gondole i stojaki – Wymagania bezpieczenstwa i metody badan E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1466","categories":["other"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Carry cots and stands – Safety requirements and test methods E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1466","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1466","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3ca","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Gondole i stojaki – Wymagania bezpieczeństwa i metody badań E","test_object_en":"Childcare articles – Carry cots and stands – Safety requirements and test methods E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 30) °"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 30) °"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa"],"technique_en":"Method: force and/or mass and/or torque loading, bench test","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","reference":"PN-EN 1466","norm_bases":["PN-EN 1466"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Gondole i stojaki – Wymagania bezpieczeństwa i metody badań E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa PN-EN 1466 Artykuly dla dzieci – Gondole i stojaki – Wymagania bezpieczenstwa i metody badan E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciazenie sila i/lub masa i/lub momentem, proba stanowiskowa PN-EN 1466","categories":["other"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Carry cots and stands – Safety requirements and test methods E Stability Method: force and/or mass and/or torque loading, bench test Range Range Range PN-EN 1466","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 30) °"}],"search_zh":"稳定性 方法：加力和/或加质量和/或加力矩载荷、台架试验 范围 范围 范围 PN-EN 1466","methodology_zh":"稳定性","technique_zh":"方法：加力和/或加质量和/或加力矩载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b3cb","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Gondole i stojaki – Wymagania bezpieczeństwa i metody badań E","test_object_en":"Childcare articles – Carry cots and stands – Safety requirements and test methods E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość,"},{"name":"skręcanie,"},{"name":"odporność na moczenie"},{"name":"Zakres","range":"(0 - 1000) N;"},{"name":"Zakres","range":"(0 - 100) kg;"},{"name":"Zakres","range":"(0 - 0,34) Nm;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability,"},{"name":"torsion,"},{"name":"resistance to soaking"},{"name":"Range","range":"(0 - 1000) N;"},{"name":"Range","range":"(0 - 100) kg;"},{"name":"Range","range":"(0 - 0,34) Nm;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba moczenia","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba moczenia"],"technique_en":"Method: loading with force and/or mass, testing with a probe, bench test, soaking test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie,\nodporność na moczenie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba moczenia","reference":"PN-EN 1466","norm_bases":["PN-EN 1466"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Gondole i stojaki – Wymagania bezpieczeństwa i metody badań E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie,\nodporność na moczenie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba moczenia PN-EN 1466 Artykuly dla dzieci – Gondole i stojaki – Wymagania bezpieczenstwa i metody badan E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc,\nskrecanie,\nodpornosc na moczenie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa, proba moczenia PN-EN 1466","categories":["other"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Carry cots and stands – Safety requirements and test methods E Strength of construction Method: loading with force and/or mass, testing with a probe, bench test, soaking test strength of the product and its components, durability, torsion, resistance to soaking Range Range Range Range Range PN-EN 1466","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性，"},{"name":"skręcanie,"},{"name":"耐浸湿性"},{"name":"范围","range":"(0 - 1000) N;"},{"name":"范围","range":"(0 - 100) kg;"},{"name":"范围","range":"(0 - 0,34) Nm;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 制品及其部件的强度， 耐久性， 耐浸湿性 范围 范围 范围 范围 范围 PN-EN 1466","methodology_zh":"结构强度"},{"_id":"6a5e78454cc76d93cba3b3cc","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble dla dzieci – Siedziska dla dzieci E","test_object_en":"Children's furniture – Seating for children E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 17191","norm_bases":["PN-EN 17191"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble dla dzieci – Siedziska dla dzieci E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nMetoda: obciążenie siłą i/lub masą PN-EN 17191 Meble dla dzieci – Siedziska dla dzieci E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nMetoda: obciazenie sila i/lub masa PN-EN 17191","categories":["other"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Children's furniture – Seating for children E Stability Method: loading with force and/or mass Range Range PN-EN 17191","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 17191","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b3cd","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble dla dzieci – Siedziska dla dzieci E","test_object_en":"Children's furniture – Seating for children E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 0,34) Nm"}],"parameters_en":[{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 0,34) Nm"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: force and/or mass and/or torque loading, probe test, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 0,34) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 17191","norm_bases":["PN-EN 17191"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble dla dzieci – Siedziska dla dzieci E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 0,34) Nm\nMetoda: obciążenie siłą i/lub masą i/lub momentem, badanie próbnikiem, próba stanowiskowa PN-EN 17191 Meble dla dzieci – Siedziska dla dzieci E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 0,34) Nm\nMetoda: obciazenie sila i/lub masa i/lub momentem, badanie probnikiem, proba stanowiskowa PN-EN 17191","categories":["other"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Children's furniture – Seating for children E Strength of construction Method: force and/or mass and/or torque loading, probe test, bench test Range Range Range PN-EN 17191","parameters_zh":[{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 0,34) Nm"}],"search_zh":"结构强度 范围 范围 范围 PN-EN 17191","methodology_zh":"结构强度"},{"_id":"6a5e78454cc76d93cba3b3ce","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble dla dzieci – Siedziska dla dzieci E","test_object_en":"Children's furniture – Seating for children E","methodology":"Wymiary geometryczne Zakres: (0 - 5000) mm; (0 - 360) °","methodology_en":"Geometric dimensions Range: (0 - 5000) mm; (0 - 360) °","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne Zakres: (0 - 5000) mm; (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 17191","norm_bases":["PN-EN 17191"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble dla dzieci – Siedziska dla dzieci E Wymiary geometryczne Zakres: (0 - 5000) mm; (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 17191 Meble dla dzieci – Siedziska dla dzieci E Wymiary geometryczne Zakres: (0 - 5000) mm; (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 17191","categories":["other"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Children's furniture – Seating for children E Geometric dimensions Range: (0 - 5000) mm; (0 - 360) ° Method: direct measurement, probe testing PN-EN 17191","search_zh":"方法：直接测量、探头检测 PN-EN 17191","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3cf","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Naczynia kuchenne E","test_object_en":"Cookware E","methodology":"Odporność na zmywanie mechaniczne","methodology_en":"Resistance to mechanical washing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zmywanie mechaniczne","reference":"PN-EN 12875-1","norm_bases":["PN-EN 12875-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Naczynia kuchenne E Odporność na zmywanie mechaniczne PN-EN 12875-1 Naczynia kuchenne E Odpornosc na zmywanie mechaniczne PN-EN 12875-1","categories":["other"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cookware E Resistance to mechanical washing PN-EN 12875-1"},{"_id":"6a5e78454cc76d93cba3b3d0","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Skateparki E","test_object_en":"Skateparks E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 20000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 20000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 14974","norm_bases":["PN-EN 14974"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skateparki E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 14974 Skateparki E Wymiary geometryczne\nZakres:\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 14974","categories":["other"],"row_index":139,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Skateparks E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 14974","parameters_zh":[{"name":"范围","range":"(0 - 20000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 14974","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3d1","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Skateparki E","test_object_en":"Skateparks E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"Zakres","range":"(0 - 7000) N;"},{"name":"Zakres","range":"(0 - 1000) kg;"},{"name":"Zakres","range":"(0 - 20000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 7000) N;"},{"name":"Range","range":"(0 - 1000) kg;"},{"name":"Range","range":"(0 - 20000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem"],"technique_en":"Method: force and/or mass loading, probe test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 7000) N;\nZakres (0 - 1000) kg;\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem","reference":"PN-EN 14974","norm_bases":["PN-EN 14974"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Skateparki E Wytrzymałość konstrukcji\nZakres:\nZakres (0 - 7000) N;\nZakres (0 - 1000) kg;\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem PN-EN 14974 Skateparki E Wytrzymalosc konstrukcji\nZakres:\nZakres (0 - 7000) N;\nZakres (0 - 1000) kg;\nZakres (0 - 20000) mm;\nZakres (0 - 360) °\nMetoda: obciazenie sila i/lub masa, badanie probnikiem PN-EN 14974","categories":["other"],"row_index":140,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Skateparks E Strength of construction Method: force and/or mass loading, probe test Range Range Range Range PN-EN 14974","parameters_zh":[{"name":"范围","range":"(0 - 7000) N;"},{"name":"范围","range":"(0 - 1000) kg;"},{"name":"范围","range":"(0 - 20000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"结构强度 方法：加力和/或加质量载荷、探棒试验 范围 范围 范围 范围 PN-EN 14974","methodology_zh":"结构强度","technique_zh":"方法：加力和/或加质量载荷、探棒试验"},{"_id":"6a5e78454cc76d93cba3b3d2","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 270) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 270) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"ASTM F 83316 CFR Part 1227","norm_bases":["ASTM F 83316 CFR Part 1227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezpośredni, badanie próbnikiem ASTM F 83316 CFR Part 1227 Artykuly dla dzieci – Wozki dzieciece E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 270) °\nMetoda: pomiar bezposredni, badanie probnikiem ASTM F 83316 CFR Part 1227","categories":["other"],"row_index":141,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Geometric dimensions Method: direct measurement, probe testing Range Range ASTM F 83316 CFR Part 1227","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 270) °"}],"search_zh":"儿童用品 － 童车 E 几何尺寸 方法：直接测量、探头检测 范围 范围 ASTM F 83316 CFR Part 1227","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"儿童用品 － 童车 E"},{"_id":"6a5e78454cc76d93cba3b3d3","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 30) °"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 30) °"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa"],"technique_en":"Method: force and/or mass and/or torque loading, bench test","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","reference":"ASTM F 83316 CFR Part 1227","norm_bases":["ASTM F 83316 CFR Part 1227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa ASTM F 83316 CFR Part 1227 Artykuly dla dzieci – Wozki dzieciece E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciazenie sila i/lub masa i/lub momentem, proba stanowiskowa ASTM F 83316 CFR Part 1227","categories":["other"],"row_index":142,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Stability Method: force and/or mass and/or torque loading, bench test Range Range Range ASTM F 83316 CFR Part 1227","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 30) °"}],"search_zh":"儿童用品 － 童车 E 稳定性 方法：加力和/或加质量和/或加力矩载荷、台架试验 范围 范围 范围 ASTM F 83316 CFR Part 1227","methodology_zh":"稳定性","test_object_zh":"儿童用品 － 童车 E","technique_zh":"方法：加力和/或加质量和/或加力矩载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b3d4","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość,"},{"name":"skręcanie"},{"name":"Zakres","range":"(0 - 1000) N;"},{"name":"Zakres","range":"(0 - 100) kg;"},{"name":"Zakres","range":"(0 - 0,34) Nm;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 5) km/h"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability,"},{"name":"torsion"},{"name":"Range","range":"(0 - 1000) N;"},{"name":"Range","range":"(0 - 100) kg;"},{"name":"Range","range":"(0 - 0,34) Nm;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 5) km/h"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) km/h\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"ASTM F 83316 CFR Part 1227","norm_bases":["ASTM F 83316 CFR Part 1227"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) km/h\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa ASTM F 83316 CFR Part 1227 Artykuly dla dzieci – Wozki dzieciece E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc,\nskrecanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 0,34) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 5) km/h\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa ASTM F 83316 CFR Part 1227","categories":["other"],"row_index":143,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability, torsion Range Range Range Range Range Range ASTM F 83316 CFR Part 1227","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性，"},{"name":"扭转"},{"name":"范围","range":"(0 - 1000) N;"},{"name":"范围","range":"(0 - 100) kg;"},{"name":"范围","range":"(0 - 0,34) Nm;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 5) km/h"}],"search_zh":"儿童用品 － 童车 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性， 扭转 范围 范围 范围 范围 范围 范围 ASTM F 83316 CFR Part 1227","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"儿童用品 － 童车 E"},{"_id":"6a5e78454cc76d93cba3b3d5","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – siedziska użytkowane poza mieszkaniem E","test_object_en":"Furniture – non-domestic seating E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, probe test, bench test, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia","reference":"ANSI/BIFMA X5.4 (p. 10, 14, 17)","norm_bases":["ANSI/BIFMA X5.4 (p. 10, 14, 17)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – siedziska użytkowane poza mieszkaniem E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia ANSI/BIFMA X5.4 (p. 10, 14, 17) Meble – siedziska uzytkowane poza mieszkaniem E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa, proba cyklicznego uderzenia ANSI/BIFMA X5.4 (p. 10, 14, 17)","categories":["other"],"row_index":144,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – non-domestic seating E Strength of construction Method: force and/or mass loading, probe test, bench test, cyclic impact test strength of the product and its components, durability Range Range Range Range ANSI/BIFMA X5.4 (p. 10, 14, 17)","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家具 － 住宅以外使用的坐具 E 结构强度 制品及其部件的强度， 耐久性 范围 范围 范围 范围 ANSI/BIFMA X5.4 (p. 10, 14, 17)","methodology_zh":"结构强度","test_object_zh":"家具 － 住宅以外使用的坐具 E"},{"_id":"6a5e78454cc76d93cba3b3d6","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – siedziska użytkowane poza mieszkaniem E","test_object_en":"Furniture – non-domestic seating E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"ANSI/BIFMA X5.4 (p. 10, 14, 17)","norm_bases":["ANSI/BIFMA X5.4 (p. 10, 14, 17)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – siedziska użytkowane poza mieszkaniem E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem ANSI/BIFMA X5.4 (p. 10, 14, 17) Meble – siedziska uzytkowane poza mieszkaniem E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem ANSI/BIFMA X5.4 (p. 10, 14, 17)","categories":["other"],"row_index":145,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – non-domestic seating E Geometric dimensions Method: direct measurement, probe testing Range Range ANSI/BIFMA X5.4 (p. 10, 14, 17)","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"家具 － 住宅以外使用的坐具 E 几何尺寸 方法：直接测量、探头检测 范围 范围 ANSI/BIFMA X5.4 (p. 10, 14, 17)","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"家具 － 住宅以外使用的坐具 E"},{"_id":"6a5e78454cc76d93cba3b3d7","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Meble do siedzenia E","test_object_en":"Furniture – Seating furniture E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1728","norm_bases":["PN-EN 1728"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Meble do siedzenia E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1728 Meble – Meble do siedzenia E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1728","categories":["other"],"row_index":146,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Seating furniture E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability Range Range Range PN-EN 1728","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 1728","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验"},{"_id":"6a5e78454cc76d93cba3b3d8","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Meble do siedzenia E","test_object_en":"Furniture – Seating furniture E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni","reference":"PN-EN 1728","norm_bases":["PN-EN 1728"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Meble do siedzenia E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni PN-EN 1728 Meble – Meble do siedzenia E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni PN-EN 1728","categories":["other"],"row_index":147,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Seating furniture E Geometric dimensions Method: direct measurement Range Range PN-EN 1728","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"几何尺寸 方法：直接测量 范围 范围 PN-EN 1728","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b3d9","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Meble do siedzenia E","test_object_en":"Furniture – Seating furniture E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 1300) N;"},{"name":"Zakres","range":"(0 - 130) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 1300) N;"},{"name":"Range","range":"(0 - 130) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 1300) N;\nZakres (0 - 130) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 1022","norm_bases":["PN-EN 1022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Meble do siedzenia E Stateczność\nZakres:\nZakres (0 - 1300) N;\nZakres (0 - 130) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 1022 Meble – Meble do siedzenia E Statecznosc\nZakres:\nZakres (0 - 1300) N;\nZakres (0 - 130) kg\nMetoda: obciazenie sila i/lub masa PN-EN 1022","categories":["other"],"row_index":148,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Seating furniture E Stability Method: loading with force and/or mass Range Range PN-EN 1022","parameters_zh":[{"name":"范围","range":"(0 - 1300) N;"},{"name":"范围","range":"(0 - 130) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 1022","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b3da","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły E","test_object_en":"Furniture – Tables E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"ANSI/BIFMA X5.5 (p. 4, 5, 6)","norm_bases":["ANSI/BIFMA X5.5 (p. 4, 5, 6)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą ANSI/BIFMA X5.5 (p. 4, 5, 6) Meble – Stoly E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa ANSI/BIFMA X5.5 (p. 4, 5, 6)","categories":["other"],"row_index":149,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Tables E Stability Method: loading with force and/or mass Range Range ANSI/BIFMA X5.5 (p. 4, 5, 6)","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"家具 － 桌 E 稳定性 方法：施加力和/或质量载荷 范围 范围 ANSI/BIFMA X5.5 (p. 4, 5, 6)","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷","test_object_zh":"家具 － 桌 E"},{"_id":"6a5e78454cc76d93cba3b3db","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły E","test_object_en":"Furniture – Tables E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, probe test, bench test, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia","reference":"ANSI/BIFMA X5.5 (p. 4, 5, 6)","norm_bases":["ANSI/BIFMA X5.5 (p. 4, 5, 6)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia ANSI/BIFMA X5.5 (p. 4, 5, 6) Meble – Stoly E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa, proba cyklicznego uderzenia ANSI/BIFMA X5.5 (p. 4, 5, 6)","categories":["other"],"row_index":150,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Tables E Strength of construction Method: force and/or mass loading, probe test, bench test, cyclic impact test strength of the product and its components, durability Range Range Range ANSI/BIFMA X5.5 (p. 4, 5, 6)","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家具 － 桌 E 结构强度 制品及其部件的强度， 耐久性 范围 范围 范围 ANSI/BIFMA X5.5 (p. 4, 5, 6)","methodology_zh":"结构强度","test_object_zh":"家具 － 桌 E"},{"_id":"6a5e78454cc76d93cba3b3dc","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły E","test_object_en":"Furniture – Tables E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"ANSI/BIFMA X5.5 (p. 4, 5, 6)","norm_bases":["ANSI/BIFMA X5.5 (p. 4, 5, 6)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem ANSI/BIFMA X5.5 (p. 4, 5, 6) Meble – Stoly E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni, badanie probnikiem ANSI/BIFMA X5.5 (p. 4, 5, 6)","categories":["other"],"row_index":151,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Tables E Geometric dimensions Method: direct measurement, probe testing Range ANSI/BIFMA X5.5 (p. 4, 5, 6)","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家具 － 桌 E 几何尺寸 方法：直接测量、探头检测 范围 ANSI/BIFMA X5.5 (p. 4, 5, 6)","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"家具 － 桌 E"},{"_id":"6a5e78454cc76d93cba3b3dd","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania odzieży E","test_object_en":"Clothing storage furniture E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 – 750) N;"},{"name":"Zakres","range":"(0 – 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 – 750) N;"},{"name":"Range","range":"(0 – 75) kg"}],"technique":"Metoda obciążenia siłą i/lub masą","techniques":["Metoda obciążenia siłą i/lub masą"],"technique_en":"Loading method with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 – 750) N;\nZakres (0 – 75) kg\nMetoda obciążenia siłą i/lub masą","reference":"ASTM F205716 CFR Part 1261","norm_bases":["ASTM F205716 CFR Part 1261"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania odzieży E Stateczność\nZakres:\nZakres (0 – 750) N;\nZakres (0 – 75) kg\nMetoda obciążenia siłą i/lub masą ASTM F205716 CFR Part 1261 Meble do przechowywania odziezy E Statecznosc\nZakres:\nZakres (0 – 750) N;\nZakres (0 – 75) kg\nMetoda obciazenia sila i/lub masa ASTM F205716 CFR Part 1261","categories":["other"],"row_index":152,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clothing storage furniture E Stability Loading method with force and/or mass Range Range ASTM F205716 CFR Part 1261","parameters_zh":[{"name":"范围","range":"(0 – 750) N;"},{"name":"范围","range":"(0 – 75) kg"}],"search_zh":"稳定性 范围 范围 ASTM F205716 CFR Part 1261","methodology_zh":"稳定性"},{"_id":"6a5e78454cc76d93cba3b3de","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble do przechowywania odzieży E","test_object_en":"Clothing storage furniture E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(1 – 5000) mm"}],"parameters_en":[{"name":"Range","range":"(1 – 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (1 – 5000) mm\nMetoda: pomiar bezpośredni","reference":"ASTM F205716 CFR Part 1261","norm_bases":["ASTM F205716 CFR Part 1261"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble do przechowywania odzieży E Wymiary geometryczne\nZakres (1 – 5000) mm\nMetoda: pomiar bezpośredni ASTM F205716 CFR Part 1261 Meble do przechowywania odziezy E Wymiary geometryczne\nZakres (1 – 5000) mm\nMetoda: pomiar bezposredni ASTM F205716 CFR Part 1261","categories":["other"],"row_index":153,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Clothing storage furniture E Geometric dimensions Method: direct measurement Range ASTM F205716 CFR Part 1261","parameters_zh":[{"name":"范围","range":"(1 – 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量 范围 ASTM F205716 CFR Part 1261","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b3df","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – panele, ekrany E","test_object_en":"Furniture – panels, screens E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","norm_bases":["ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – panele, ekrany E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą ANSI/BIFMA X5.6 (p. 5, 6, 7, 8) Meble – panele, ekrany E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","categories":["other"],"row_index":154,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – panels, screens E Stability Method: loading with force and/or mass Range Range ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"稳定性 方法：施加力和/或质量载荷 范围 范围 ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷"},{"_id":"6a5e78454cc76d93cba3b3e0","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – panele, ekrany E","test_object_en":"Furniture – panels, screens E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"strength of the product and its components"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, probe test, bench test, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia","reference":"ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","norm_bases":["ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – panele, ekrany E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa, próba cyklicznego uderzenia ANSI/BIFMA X5.6 (p. 5, 6, 7, 8) Meble – panele, ekrany E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa, proba cyklicznego uderzenia ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","categories":["other"],"row_index":155,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – panels, screens E Strength of construction Method: force and/or mass loading, probe test, bench test, cyclic impact test strength of the product and its components Range Range Range ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","parameters_zh":[{"name":"wytrzymałość wyrobu i jego elementów"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"结构强度 范围 范围 范围 ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","methodology_zh":"结构强度"},{"_id":"6a5e78454cc76d93cba3b3e1","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – panele, ekrany E","test_object_en":"Furniture – panels, screens E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","norm_bases":["ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – panele, ekrany E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni, badanie próbnikiem ANSI/BIFMA X5.6 (p. 5, 6, 7, 8) Meble – panele, ekrany E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni, badanie probnikiem ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","categories":["other"],"row_index":156,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – panels, screens E Geometric dimensions Method: direct measurement, probe testing Range ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 ANSI/BIFMA X5.6 (p. 5, 6, 7, 8)","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3e2","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Sztućce i przybory stołowe (wyroby nożowe) E","test_object_en":"Cutlery and table articles (cutlery products) E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 – 5000) mm"},{"name":"Zakres","range":"(0 – 270) ̊"}],"parameters_en":[{"name":"Range","range":"(0 – 5000) mm"},{"name":"Range","range":"(0 – 270) ̊"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 – 5000) mm\nZakres (0 – 270) ̊\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","norm_bases":["EN ISO 8442-1 (pkt. 5.3, Annex A.1.)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sztućce i przybory stołowe (wyroby nożowe) E Wymiary geometryczne\nZakres:\nZakres (0 – 5000) mm\nZakres (0 – 270) ̊\nMetoda: pomiar bezpośredni, badanie próbnikiem EN ISO 8442-1 (pkt. 5.3, Annex A.1.) Sztucce i przybory stolowe (wyroby nozowe) E Wymiary geometryczne\nZakres:\nZakres (0 – 5000) mm\nZakres (0 – 270) \nMetoda: pomiar bezposredni, badanie probnikiem EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","categories":["other"],"row_index":157,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cutlery and table articles (cutlery products) E Geometric dimensions Method: direct measurement, probe testing Range Range EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","parameters_zh":[{"name":"范围","range":"(0 – 5000) mm"},{"name":"范围","range":"(0 – 270) ̊"}],"search_zh":"几何尺寸 方法：直接测量、探头检测 范围 范围 EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测"},{"_id":"6a5e78454cc76d93cba3b3e3","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Sztućce i przybory stołowe (wyroby nożowe) E","test_object_en":"Cutlery and table articles (cutlery products) E","methodology":"Odporność na korozję","methodology_en":"Corrosion resistance","parameters":[],"parameters_en":[],"technique":"Metoda zanurzeniowa","techniques":["Metoda zanurzeniowa"],"technique_en":"Immersion method","computed":[],"computed_en":[],"activity":"Odporność na korozję\nMetoda zanurzeniowa","reference":"EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","norm_bases":["EN ISO 8442-1 (pkt. 5.3, Annex A.1.)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sztućce i przybory stołowe (wyroby nożowe) E Odporność na korozję\nMetoda zanurzeniowa EN ISO 8442-1 (pkt. 5.3, Annex A.1.) Sztucce i przybory stolowe (wyroby nozowe) E Odpornosc na korozje\nMetoda zanurzeniowa EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","categories":["other"],"row_index":158,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cutlery and table articles (cutlery products) E Corrosion resistance Immersion method EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","methodology_zh":"耐腐蚀性","search_zh":"耐腐蚀性 浸没法 EN ISO 8442-1 (pkt. 5.3, Annex A.1.)","technique_zh":"浸没法"},{"_id":"6a5e78454cc76d93cba3b3e4","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Sztućce i przybory stołowe (wyroby nożowe) E","test_object_en":"Cutlery and table articles (cutlery products) E","methodology":"Zdolność cięcia","methodology_en":"Cutting capacity","parameters":[],"parameters_en":[],"technique":"Metoda: próba stanowiskowa","techniques":["Metoda: próba stanowiskowa"],"technique_en":"Method: bench test","computed":[],"computed_en":[],"activity":"Zdolność cięcia\nMetoda: próba stanowiskowa","reference":"EN ISO 8442-5","norm_bases":["EN ISO 8442-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sztućce i przybory stołowe (wyroby nożowe) E Zdolność cięcia\nMetoda: próba stanowiskowa EN ISO 8442-5 Sztucce i przybory stolowe (wyroby nozowe) E Zdolnosc ciecia\nMetoda: proba stanowiskowa EN ISO 8442-5","categories":["other"],"row_index":159,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cutlery and table articles (cutlery products) E Cutting capacity Method: bench test EN ISO 8442-5"},{"_id":"6a5e78454cc76d93cba3b3e5","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 360) °"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 360) °"}],"technique":"Metoda: pomiar bezpośredni, badanie próbnikiem","techniques":["Metoda: pomiar bezpośredni, badanie próbnikiem"],"technique_en":"Method: direct measurement, probe testing","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem","reference":"PN-EN 1888-3","norm_bases":["PN-EN 1888-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezpośredni, badanie próbnikiem PN-EN 1888-3 Artykuly dla dzieci – Wozki dzieciece E Wymiary geometryczne\nZakres:\nZakres (0 - 5000) mm;\nZakres (0 - 360) °\nMetoda: pomiar bezposredni, badanie probnikiem PN-EN 1888-3","categories":["other"],"row_index":160,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Geometric dimensions Method: direct measurement, probe testing Range Range PN-EN 1888-3","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 360) °"}],"search_zh":"儿童用品 － 童车 E 几何尺寸 方法：直接测量、探头检测 范围 范围 PN-EN 1888-3","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量、探头检测","test_object_zh":"儿童用品 － 童车 E"},{"_id":"6a5e78454cc76d93cba3b3e6","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg;"},{"name":"Zakres","range":"(0 - 30) °"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg;"},{"name":"Range","range":"(0 - 30) °"}],"technique":"Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa"],"technique_en":"Method: force and/or mass and/or torque loading, bench test","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa","reference":"PN-EN 1888-3","norm_bases":["PN-EN 1888-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciążenie siłą i/lub masą i/lub momentem, próba stanowiskowa PN-EN 1888-3 Artykuly dla dzieci – Wozki dzieciece E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg;\nZakres (0 - 30) °\nMetoda: obciazenie sila i/lub masa i/lub momentem, proba stanowiskowa PN-EN 1888-3","categories":["other"],"row_index":161,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Stability Method: force and/or mass and/or torque loading, bench test Range Range Range PN-EN 1888-3","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg;"},{"name":"范围","range":"(0 - 30) °"}],"search_zh":"儿童用品 － 童车 E 稳定性 方法：加力和/或加质量和/或加力矩载荷、台架试验 范围 范围 范围 PN-EN 1888-3","methodology_zh":"稳定性","test_object_zh":"儿童用品 － 童车 E","technique_zh":"方法：加力和/或加质量和/或加力矩载荷、台架试验"},{"_id":"6a5e78454cc76d93cba3b3e7","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Artykuły dla dzieci – Wózki dziecięce E","test_object_en":"Childcare articles – Prams and pushchairs E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość,"},{"name":"skręcanie"},{"name":"Zakres","range":"(0 - 1000) N;"},{"name":"Zakres","range":"(0 - 100) kg;"},{"name":"Zakres","range":"(0 - 6,5) Nm;"},{"name":"Zakres","range":"(0 - 360) °;"},{"name":"Zakres","range":"(0 - 5000) mm;"},{"name":"Zakres","range":"(0 - 8) km/h"}],"parameters_en":[{"name":"strength of the product and its components,"},{"name":"durability,"},{"name":"torsion"},{"name":"Range","range":"(0 - 1000) N;"},{"name":"Range","range":"(0 - 100) kg;"},{"name":"Range","range":"(0 - 6,5) Nm;"},{"name":"Range","range":"(0 - 360) °;"},{"name":"Range","range":"(0 - 5000) mm;"},{"name":"Range","range":"(0 - 8) km/h"}],"technique":"Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","techniques":["Metoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa"],"technique_en":"Method: loading with force and/or mass, probe testing, bench test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 6,5) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 8) km/h\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa","reference":"PN-EN 1888-3","norm_bases":["PN-EN 1888-3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Artykuły dla dzieci – Wózki dziecięce E Wytrzymałość konstrukcji\nZakres:\nwytrzymałość wyrobu i jego elementów,\ntrwałość,\nskręcanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 6,5) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 8) km/h\nMetoda: obciążenie siłą i/lub masą, badanie próbnikiem, próba stanowiskowa PN-EN 1888-3 Artykuly dla dzieci – Wozki dzieciece E Wytrzymalosc konstrukcji\nZakres:\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc,\nskrecanie\nZakres (0 - 1000) N;\nZakres (0 - 100) kg;\nZakres (0 - 6,5) Nm;\nZakres (0 - 360) °;\nZakres (0 - 5000) mm;\nZakres (0 - 8) km/h\nMetoda: obciazenie sila i/lub masa, badanie probnikiem, proba stanowiskowa PN-EN 1888-3","categories":["other"],"row_index":162,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Childcare articles – Prams and pushchairs E Strength of construction Method: loading with force and/or mass, probe testing, bench test strength of the product and its components, durability, torsion Range Range Range Range Range Range PN-EN 1888-3","parameters_zh":[{"name":"制品及其部件的强度，"},{"name":"耐久性，"},{"name":"扭转"},{"name":"范围","range":"(0 - 1000) N;"},{"name":"范围","range":"(0 - 100) kg;"},{"name":"范围","range":"(0 - 6,5) Nm;"},{"name":"范围","range":"(0 - 360) °;"},{"name":"范围","range":"(0 - 5000) mm;"},{"name":"范围","range":"(0 - 8) km/h"}],"search_zh":"儿童用品 － 童车 E 结构强度 方法：施加力和/或质量载荷、探头检测、台架试验 制品及其部件的强度， 耐久性， 扭转 范围 范围 范围 范围 范围 范围 PN-EN 1888-3","methodology_zh":"结构强度","technique_zh":"方法：施加力和/或质量载荷、探头检测、台架试验","test_object_zh":"儿童用品 － 童车 E"},{"_id":"6a5e78454cc76d93cba3b3e8","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły E","test_object_en":"Furniture – Tables E","methodology":"Stateczność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 - 750) N;"},{"name":"Zakres","range":"(0 - 75) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 750) N;"},{"name":"Range","range":"(0 - 75) kg"}],"technique":"Metoda: obciążenie siłą i/lub masą","techniques":["Metoda: obciążenie siłą i/lub masą"],"technique_en":"Method: loading with force and/or mass","computed":[],"computed_en":[],"activity":"Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą","reference":"PN-EN 1730","norm_bases":["PN-EN 1730"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły E Stateczność\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciążenie siłą i/lub masą PN-EN 1730 Meble – Stoly E Statecznosc\nZakres:\nZakres (0 - 750) N;\nZakres (0 - 75) kg\nMetoda: obciazenie sila i/lub masa PN-EN 1730","categories":["other"],"row_index":163,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Tables E Stability Method: loading with force and/or mass Range Range PN-EN 1730","parameters_zh":[{"name":"范围","range":"(0 - 750) N;"},{"name":"范围","range":"(0 - 75) kg"}],"search_zh":"家具 － 桌 E 稳定性 方法：施加力和/或质量载荷 范围 范围 PN-EN 1730","methodology_zh":"稳定性","technique_zh":"方法：施加力和/或质量载荷","test_object_zh":"家具 － 桌 E"},{"_id":"6a5e78454cc76d93cba3b3e9","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły E","test_object_en":"Furniture – Tables E","methodology":"Wytrzymałość konstrukcji","methodology_en":"Strength of construction","parameters":[{"name":"ugięcie,"},{"name":"wytrzymałość wyrobu i jego elementów,"},{"name":"trwałość"},{"name":"Zakres","range":"(0 - 4500) N;"},{"name":"Zakres","range":"(0 - 450) kg;"},{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"deflection,"},{"name":"strength of the product and its components,"},{"name":"durability"},{"name":"Range","range":"(0 - 4500) N;"},{"name":"Range","range":"(0 - 450) kg;"},{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","techniques":["Metoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia"],"technique_en":"Method: force and/or mass loading, cyclic impact test","computed":[],"computed_en":[],"activity":"Wytrzymałość konstrukcji\nZakres:\nugięcie,\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia","reference":"PN-EN 1730","norm_bases":["PN-EN 1730"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły E Wytrzymałość konstrukcji\nZakres:\nugięcie,\nwytrzymałość wyrobu i jego elementów,\ntrwałość\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciążenie siłą i/lub masą, próba cyklicznego uderzenia PN-EN 1730 Meble – Stoly E Wytrzymalosc konstrukcji\nZakres:\nugiecie,\nwytrzymalosc wyrobu i jego elementow,\ntrwalosc\nZakres (0 - 4500) N;\nZakres (0 - 450) kg;\nZakres (0 - 5000) mm\nMetoda: obciazenie sila i/lub masa, proba cyklicznego uderzenia PN-EN 1730","categories":["other"],"row_index":164,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Tables E Strength of construction Method: force and/or mass loading, cyclic impact test deflection, strength of the product and its components, durability Range Range Range PN-EN 1730","parameters_zh":[{"name":"ugięcie,"},{"name":"制品及其部件的强度，"},{"name":"耐久性"},{"name":"范围","range":"(0 - 4500) N;"},{"name":"范围","range":"(0 - 450) kg;"},{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家具 － 桌 E 结构强度 方法：加力和/或加质量载荷、循环冲击试验 制品及其部件的强度， 耐久性 范围 范围 范围 PN-EN 1730","methodology_zh":"结构强度","test_object_zh":"家具 － 桌 E","technique_zh":"方法：加力和/或加质量载荷、循环冲击试验"},{"_id":"6a5e78454cc76d93cba3b3ea","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Meble – Stoły E","test_object_en":"Furniture – Tables E","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 - 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 - 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN 1730","norm_bases":["PN-EN 1730"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Meble – Stoły E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezpośredni PN-EN 1730 Meble – Stoly E Wymiary geometryczne\nZakres (0 - 5000) mm\nMetoda: pomiar bezposredni PN-EN 1730","categories":["other"],"row_index":165,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Furniture – Tables E Geometric dimensions Method: direct measurement Range PN-EN 1730","parameters_zh":[{"name":"范围","range":"(0 - 5000) mm"}],"search_zh":"家具 － 桌 E 几何尺寸 方法：直接测量 范围 PN-EN 1730","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量","test_object_zh":"家具 － 桌 E"},{"_id":"6a5e78454cc76d93cba3b3eb","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Materiały metaliczne i z tworzywa sztucznego","test_object_en":"Metallic and plastic materials","methodology":"Antypoślizgowość powierzchni","methodology_en":"Surface slip resistance","parameters":[{"name":"Zakres","range":"(0 - 45) °"}],"parameters_en":[{"name":"Range","range":"(0 - 45) °"}],"technique":"Metoda: próba stateczności na pochylni","techniques":["Metoda: próba stateczności na pochylni"],"technique_en":"Method: stability test on an inclined plane","computed":[],"computed_en":[],"activity":"Antypoślizgowość powierzchni\nZakres (0 - 45) °\nMetoda: próba stateczności na pochylni","reference":"DIN 51097:1992","norm_bases":["DIN 51097:1992"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały metaliczne i z tworzywa sztucznego Antypoślizgowość powierzchni\nZakres (0 - 45) °\nMetoda: próba stateczności na pochylni DIN 51097:1992 Materialy metaliczne i z tworzywa sztucznego Antyposlizgowosc powierzchni\nZakres (0 - 45) °\nMetoda: proba statecznosci na pochylni DIN 51097:1992","categories":["materials"],"row_index":166,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metallic and plastic materials Surface slip resistance Method: stability test on an inclined plane Range DIN 51097:1992","parameters_zh":[{"name":"范围","range":"(0 - 45) °"}],"search_zh":"范围 DIN 51097:1992"},{"_id":"6a5e78454cc76d93cba3b3ec","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Pomiar wielkości fizycznych wyrobów użytkowych","test_object_en":"Measurement of physical quantities of consumer products","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 – 20000) mm"},{"name":"Zakres","range":"(0 – 270) ̊"}],"parameters_en":[{"name":"Range","range":"(0 – 20000) mm"},{"name":"Range","range":"(0 – 270) ̊"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres:\nZakres (0 – 20000) mm\nZakres (0 – 270) ̊\nMetoda: pomiar bezpośredni","reference":"IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","norm_bases":["IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomiar wielkości fizycznych wyrobów użytkowych Wymiary geometryczne\nZakres:\nZakres (0 – 20000) mm\nZakres (0 – 270) ̊\nMetoda: pomiar bezpośredni IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025 Pomiar wielkosci fizycznych wyrobow uzytkowych Wymiary geometryczne\nZakres:\nZakres (0 – 20000) mm\nZakres (0 – 270) \nMetoda: pomiar bezposredni IP-TUV-25 Pomiar wielkosci fizycznych wyrobow uzytkowych, wyd. I z dnia 03.02.2025","categories":["other"],"row_index":167,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measurement of physical quantities of consumer products Geometric dimensions Method: direct measurement Range Range IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","parameters_zh":[{"name":"范围","range":"(0 – 20000) mm"},{"name":"范围","range":"(0 – 270) ̊"}],"search_zh":"使用制品物理量的测量 几何尺寸 方法：直接测量 范围 范围 IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量","test_object_zh":"使用制品物理量的测量"},{"_id":"6a5e78454cc76d93cba3b3ed","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Pomiar wielkości fizycznych wyrobów użytkowych","test_object_en":"Measurement of physical quantities of consumer products","methodology":"Temperatura otoczenia","methodology_en":"Ambient temperature","parameters":[{"name":"Zakres","range":"(od-20 do +60)°C"}],"parameters_en":[{"name":"Range","range":"(od-20 do +60)°C"}],"technique":"Metoda: Pomiar temperatury","techniques":["Metoda: Pomiar temperatury"],"technique_en":"Method: Temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura otoczenia\nZakres (od-20 do +60)°C\nMetoda: Pomiar temperatury","reference":"IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","norm_bases":["IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomiar wielkości fizycznych wyrobów użytkowych Temperatura otoczenia\nZakres (od-20 do +60)°C\nMetoda: Pomiar temperatury IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025 Pomiar wielkosci fizycznych wyrobow uzytkowych Temperatura otoczenia\nZakres (od-20 do +60)°C\nMetoda: Pomiar temperatury IP-TUV-25 Pomiar wielkosci fizycznych wyrobow uzytkowych, wyd. I z dnia 03.02.2025","categories":["other"],"row_index":168,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measurement of physical quantities of consumer products Ambient temperature Method: Temperature measurement Range IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","parameters_zh":[{"name":"范围","range":"(od-20 do +60)°C"}],"search_zh":"使用制品物理量的测量 方法：温度测量 范围 IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","technique_zh":"方法：温度测量","test_object_zh":"使用制品物理量的测量"},{"_id":"6a5e78454cc76d93cba3b3ee","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Pomiar wielkości fizycznych wyrobów użytkowych","test_object_en":"Measurement of physical quantities of consumer products","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(od -50 do +800)°C"}],"parameters_en":[{"name":"Range","range":"(od -50 do +800)°C"}],"technique":"Metoda: Pomiar temperatury","techniques":["Metoda: Pomiar temperatury"],"technique_en":"Method: Temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do +800)°C\nMetoda: Pomiar temperatury","reference":"IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","norm_bases":["IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomiar wielkości fizycznych wyrobów użytkowych Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do +800)°C\nMetoda: Pomiar temperatury IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025 Pomiar wielkosci fizycznych wyrobow uzytkowych Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (od -50 do +800)°C\nMetoda: Pomiar temperatury IP-TUV-25 Pomiar wielkosci fizycznych wyrobow uzytkowych, wyd. I z dnia 03.02.2025","categories":["other"],"row_index":169,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measurement of physical quantities of consumer products Temperature emitted by various parts of the appliance Method: Temperature measurement Range IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","parameters_zh":[{"name":"范围","range":"(od -50 do +800)°C"}],"search_zh":"使用制品物理量的测量 设备各部件散发的温度 方法：温度测量 范围 IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","methodology_zh":"设备各部件散发的温度","technique_zh":"方法：温度测量","test_object_zh":"使用制品物理量的测量"},{"_id":"6a5e78454cc76d93cba3b3ef","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Pomiar wielkości fizycznych wyrobów użytkowych","test_object_en":"Measurement of physical quantities of consumer products","methodology":"Wilgotność otoczenia","methodology_en":"Ambient humidity","parameters":[{"name":"Zakres","range":"(25 - 90) %"}],"parameters_en":[{"name":"Range","range":"(25 - 90) %"}],"technique":"Metoda: pomiar wilgotności","techniques":["Metoda: pomiar wilgotności"],"technique_en":"Method: moisture measurement","computed":[],"computed_en":[],"activity":"Wilgotność otoczenia\nZakres (25 - 90) %\nMetoda: pomiar wilgotności","reference":"IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","norm_bases":["IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomiar wielkości fizycznych wyrobów użytkowych Wilgotność otoczenia\nZakres (25 - 90) %\nMetoda: pomiar wilgotności IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025 Pomiar wielkosci fizycznych wyrobow uzytkowych Wilgotnosc otoczenia\nZakres (25 - 90) %\nMetoda: pomiar wilgotnosci IP-TUV-25 Pomiar wielkosci fizycznych wyrobow uzytkowych, wyd. I z dnia 03.02.2025","categories":["other"],"row_index":170,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measurement of physical quantities of consumer products Ambient humidity Method: moisture measurement Range IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","parameters_zh":[{"name":"范围","range":"(25 - 90) %"}],"search_zh":"使用制品物理量的测量 范围 IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","test_object_zh":"使用制品物理量的测量"},{"_id":"6a5e78454cc76d93cba3b3f0","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Pomiar wielkości fizycznych wyrobów użytkowych","test_object_en":"Measurement of physical quantities of consumer products","methodology":"Czas działania/ czas trwania","methodology_en":"Operating time/ duration","parameters":[{"name":"Zakres","range":"(0 - 60) min"}],"parameters_en":[{"name":"Range","range":"(0 - 60) min"}],"technique":"Metoda: pomiar czasu","techniques":["Metoda: pomiar czasu"],"technique_en":"Method: time measurement","computed":[],"computed_en":[],"activity":"Czas działania/ czas trwania\nZakres (0 - 60) min\nMetoda: pomiar czasu","reference":"IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","norm_bases":["IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomiar wielkości fizycznych wyrobów użytkowych Czas działania/ czas trwania\nZakres (0 - 60) min\nMetoda: pomiar czasu IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025 Pomiar wielkosci fizycznych wyrobow uzytkowych Czas dzialania/ czas trwania\nZakres (0 - 60) min\nMetoda: pomiar czasu IP-TUV-25 Pomiar wielkosci fizycznych wyrobow uzytkowych, wyd. I z dnia 03.02.2025","categories":["other"],"row_index":171,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measurement of physical quantities of consumer products Operating time/ duration Method: time measurement Range IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","parameters_zh":[{"name":"范围","range":"(0 - 60) min"}],"search_zh":"使用制品物理量的测量 方法：时间测量 范围 IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","test_object_zh":"使用制品物理量的测量","technique_zh":"方法：时间测量"},{"_id":"6a5e78454cc76d93cba3b3f1","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Pomiar wielkości fizycznych wyrobów użytkowych","test_object_en":"Measurement of physical quantities of consumer products","methodology":"Waga","methodology_en":"Weight","parameters":[{"name":"Zakres","range":"(0 - 150) kg"}],"parameters_en":[{"name":"Range","range":"(0 - 150) kg"}],"technique":"Metoda: pomiar masy","techniques":["Metoda: pomiar masy"],"technique_en":"Method: mass measurement","computed":[],"computed_en":[],"activity":"Waga\nZakres (0 - 150) kg\nMetoda: pomiar masy","reference":"IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","norm_bases":["IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomiar wielkości fizycznych wyrobów użytkowych Waga\nZakres (0 - 150) kg\nMetoda: pomiar masy IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025 Pomiar wielkosci fizycznych wyrobow uzytkowych Waga\nZakres (0 - 150) kg\nMetoda: pomiar masy IP-TUV-25 Pomiar wielkosci fizycznych wyrobow uzytkowych, wyd. I z dnia 03.02.2025","categories":["other"],"row_index":172,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Measurement of physical quantities of consumer products Weight Method: mass measurement Range IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","parameters_zh":[{"name":"范围","range":"(0 - 150) kg"}],"search_zh":"使用制品物理量的测量 范围 IP-TÜV-25 Pomiar wielkości fizycznych wyrobów użytkowych, wyd. I z dnia 03.02.2025","test_object_zh":"使用制品物理量的测量"},{"_id":"6a5e78454cc76d93cba3b3f2","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Moc pobierana","methodology_en":"Power consumption","parameters":[{"name":"Zakres","range":"(0,001 - 9000,0) W"},{"name":"Zakres","range":"(0,001 - 9000,0) VA"}],"parameters_en":[{"name":"Range","range":"(0,001 - 9000,0) W"},{"name":"Range","range":"(0,001 - 9000,0) VA"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":173,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Power consumption Method: direct measurement Range Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,001 - 9000,0) W"},{"name":"范围","range":"(0,001 - 9000,0) VA"}],"search_zh":"医用电气设备 消耗功率 方法：直接测量 范围 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备","methodology_zh":"消耗功率"},{"_id":"6a5e78454cc76d93cba3b3f3","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Napięcie","methodology_en":"Voltage","parameters":[{"name":"Zakres","range":"(0,001 - 900) V"}],"parameters_en":[{"name":"Range","range":"(0,001 - 900) V"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Napiecie\nZakres (0,001 - 900) V\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":174,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Voltage Method: direct measurement Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,001 - 900) V"}],"search_zh":"医用电气设备 电压 方法：直接测量 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备","methodology_zh":"电压"},{"_id":"6a5e78454cc76d93cba3b3f4","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Prąd","methodology_en":"Current","parameters":[{"name":"Zakres","range":"(0,001 - 30) A"}],"parameters_en":[{"name":"Range","range":"(0,001 - 30) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Prad\nZakres (0,001 - 30) A\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":175,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Current Method: direct measurement Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,001 - 30) A"}],"search_zh":"医用电气设备 电流 方法：直接测量 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备","methodology_zh":"电流"},{"_id":"6a5e78454cc76d93cba3b3f5","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Czytelność oznakowania","methodology_en":"Legibility of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Pomiar bezpośredni","techniques":["Metoda: Pomiar bezpośredni"],"technique_en":"Method: Direct measurement","computed":[],"computed_en":[],"activity":"Czytelność oznakowania\nMetoda: Pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Czytelność oznakowania\nMetoda: Pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Czytelnosc oznakowania\nMetoda: Pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":176,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Legibility of marking Method: Direct measurement PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 标识的清晰度 方法：直接测量 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"标识的清晰度","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b3f6","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Trwałość oznakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Próba trwałości oznakowania (woda, alkohol)","techniques":["Metoda: Próba trwałości oznakowania (woda, alkohol)"],"technique_en":"Method: Marking durability test (water, alcohol)","computed":[],"computed_en":[],"activity":"Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol)","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol) PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Trwalosc oznakowania\nMetoda: Proba trwalosci oznakowania (woda, alkohol) PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["water"],"row_index":177,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Durability of marking Method: Marking durability test (water, alcohol) PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 标识耐久性 方法：标识耐久性试验（水、酒精） PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"标识耐久性","technique_zh":"方法：标识耐久性试验（水、酒精）"},{"_id":"6a5e78454cc76d93cba3b3f7","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Impedancja obwodu ochronnego prądem min. 25 A","methodology_en":"Impedance of the protective circuit at a current of min. 25 A","parameters":[{"name":"Zakres","range":"(0,001 - 2,1) Ω"}],"parameters_en":[{"name":"Range","range":"(0,001 - 2,1) Ω"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Impedancja obwodu ochronnego prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Impedancja obwodu ochronnego prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Impedancja obwodu ochronnego pradem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":178,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Impedance of the protective circuit at a current of min. 25 A Method: direct measurement Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,001 - 2,1) Ω"}],"search_zh":"医用电气设备 方法：直接测量 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备"},{"_id":"6a5e78454cc76d93cba3b3f8","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Prądy upływu, prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)","methodology_en":"Leakage currents, earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part)","parameters":[{"name":"Zakres","range":"(0 - 10) A"}],"parameters_en":[{"name":"Range","range":"(0 - 10) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prądy upływu, prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Prądy upływu, prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Prady uplywu, prad uplywu uziomowy, prad uplywu obudowy, prad uplywu pacjenta, prad pomocniczy pacjenta, prad uplywu pacjenta (napiecie sieciowe na czesci aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":179,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Leakage currents, earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part) Method: direct measurement Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0 - 10) A"}],"search_zh":"医用电气设备 方法：直接测量 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备"},{"_id":"6a5e78454cc76d93cba3b3f9","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wytrzymalosc elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["construction"],"row_index":180,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Dielectric strength of the insulation Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 绝缘介电强度 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"绝缘介电强度"},{"_id":"6a5e78454cc76d93cba3b3fa","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Odkształcenie obudowy przy próbie odporności na ciepło","methodology_en":"Deformation of the enclosure in the heat resistance test","parameters":[],"parameters_en":[],"technique":"Metoda: Próba wciskania kulki","techniques":["Metoda: Próba wciskania kulki"],"technique_en":"Method: Ball pressure test","computed":[],"computed_en":[],"activity":"Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Odksztalcenie obudowy przy probie odpornosci na cieplo\nMetoda: Proba wciskania kulki PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":181,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Deformation of the enclosure in the heat resistance test Method: Ball pressure test PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 耐热试验时外壳的变形 方法：球压试验 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"耐热试验时外壳的变形","technique_zh":"方法：球压试验"},{"_id":"6a5e78454cc76d93cba3b3fb","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Odstępy izolacyjne powierzchniowe i powietrzne","methodology_en":"Creepage distances and clearances","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Odstepy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["construction"],"row_index":182,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Creepage distances and clearances Method: direct measurement PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 爬电距离与电气间隙 方法：直接测量 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备","methodology_zh":"爬电距离与电气间隙"},{"_id":"6a5e78454cc76d93cba3b3fc","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)","methodology_en":"Insulation of the mains supply cord (cord anchorage and bend protection)","parameters":[{"name":"siła","range":"(0,1 - 100) N, moment"},{"name":"skręcający","range":"(0,001 - 0,35) Nm"}],"parameters_en":[{"name":"force","range":"(0,1 - 100) N, moment"},{"name":"torsional","range":"(0,001 - 0,35) Nm"}],"technique":"Metoda: próba obciążenia i próba skręcania","techniques":["Metoda: próba obciążenia i próba skręcania"],"technique_en":"Method: load test and torsion test","computed":[],"computed_en":[],"activity":"Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)\nZakres:\nsiła (0,1 - 100) N, moment\nskręcający (0,001 - 0,35) Nm\nMetoda: próba obciążenia i próba skręcania","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)\nZakres:\nsiła (0,1 - 100) N, moment\nskręcający (0,001 - 0,35) Nm\nMetoda: próba obciążenia i próba skręcania PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Izolacja przewodu zasilania sieciowego (odciazka i odgietka przewodu)\nZakres:\nsila (0,1 - 100) N, moment\nskrecajacy (0,001 - 0,35) Nm\nMetoda: proba obciazenia i proba skrecania PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["construction"],"row_index":183,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Insulation of the mains supply cord (cord anchorage and bend protection) Method: load test and torsion test force torsional PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"力","range":"(0,1 - 100) N, moment"},{"name":"skręcający","range":"(0,001 - 0,35) Nm"}],"search_zh":"医用电气设备 力 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备"},{"_id":"6a5e78454cc76d93cba3b3fd","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Szczeliny w ochronie przed zagrożeniami mechanicznymi","methodology_en":"Gaps in protection against mechanical hazards","parameters":[{"name":"Zakres","range":"(0,1 - 1000) mm"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1000) mm"}],"technique":"Metoda: pomiar wielkości liniowych","techniques":["Metoda: pomiar wielkości liniowych"],"technique_en":"Method: measurement of linear dimensions","computed":[],"computed_en":[],"activity":"Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Szczeliny w ochronie przed zagrozeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkosci liniowych PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":184,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Gaps in protection against mechanical hazards Method: measurement of linear dimensions Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,1 - 1000) mm"}],"search_zh":"医用电气设备 机械危险防护中的开口 方法：线性量测量 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"机械危险防护中的开口","technique_zh":"方法：线性量测量"},{"_id":"6a5e78454cc76d93cba3b3fe","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych","methodology_en":"Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces","parameters":[{"name":"Zakres","range":"(0 - 30)°, siła (0,1 - 800) N"}],"parameters_en":[{"name":"Range","range":"(0 - 30)°, siła (0,1 - 800) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres (0 - 30)°, siła (0,1 - 800) N\nMetoda: próba stateczności","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres (0 - 30)°, siła (0,1 - 800) N\nMetoda: próba stateczności PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Niestabilnosc urzadzenia w pozycji transportowej, poza transportem oraz w wyniku dzialania sil poziomych i pionowych\nZakres (0 - 30)°, sila (0,1 - 800) N\nMetoda: proba statecznosci PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":185,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces Method: stability test Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0 - 30)°, siła (0,1 - 800) N"}],"search_zh":"医用电气设备 设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性 方法：稳定性试验 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b3ff","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu","methodology_en":"Instability of the device during transport and other than during transport","parameters":[{"name":"kąt","range":"(0 - 30)°"},{"name":"siła","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"angle","range":"(0 - 30)°"},{"name":"force","range":"(0,1 - 350) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Niestabilnosc urzadzenia podczas transportu oraz z wyjatkiem transportu\nZakres:\nkat (0 - 30)°\nsila (0,1 - 350) N\nMetoda: proba statecznosci PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":186,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Instability of the device during transport and other than during transport Method: stability test angle force PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"角度","range":"(0 - 30)°"},{"name":"力","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 设备在运输过程中及运输以外情况下的不稳定性 方法：稳定性试验 角度 力 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输过程中及运输以外情况下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b400","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Siła umożliwiająca wprawienie w ruch urządzenia","methodology_en":"Force required to set the equipment in motion","parameters":[{"name":"Zakres","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 350) N"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Sila umozliwiajaca wprawienie w ruch urzadzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":187,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Force required to set the equipment in motion Method: direct measurement Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 使设备启动所需的力 方法：直接测量 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备","methodology_zh":"使设备启动所需的力"},{"_id":"6a5e78454cc76d93cba3b401","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Zdolność urządzenia do przejazdu przez próg","methodology_en":"Ability of the device to pass over a threshold","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność urządzenia do przejazdu przez próg","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Zdolność urządzenia do przejazdu przez próg PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Zdolnosc urzadzenia do przejazdu przez prog PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":188,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Ability of the device to pass over a threshold PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 设备越过门槛的通过能力 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"设备越过门槛的通过能力"},{"_id":"6a5e78454cc76d93cba3b402","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń","methodology_en":"Mechanical strength of handles and other means for carrying equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wytrzymalosc mechaniczna uchwytow i innych srodkow do przenoszenia urzadzen\nMetoda: proba obciazenia PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":189,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Mechanical strength of handles and other means for carrying equipment Method: load test PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 把手及其他搬运设备用件的机械强度 方法：荷载试验 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","technique_zh":"方法：荷载试验","methodology_zh":"把手及其他搬运设备用件的机械强度"},{"_id":"6a5e78454cc76d93cba3b403","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość mechaniczna systemów podtrzymywania","methodology_en":"Mechanical strength of support systems","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wytrzymalosc mechaniczna systemow podtrzymywania\nMetoda: proba obciazenia PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":190,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Mechanical strength of support systems Method: load test PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 支撑系统的机械强度 方法：荷载试验 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","technique_zh":"方法：荷载试验","methodology_zh":"支撑系统的机械强度"},{"_id":"6a5e78454cc76d93cba3b404","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(-50 - 800)°C"}],"parameters_en":[{"name":"Range","range":"(-50 - 800)°C"}],"technique":"Metoda: Pomiar temperatury","techniques":["Metoda: Pomiar temperatury"],"technique_en":"Method: Temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Temperatura wydzielana przez różne części urządzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":191,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Temperature emitted by various parts of the appliance Method: Temperature measurement Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(-50 - 800)°C"}],"search_zh":"医用电气设备 设备各部件散发的温度 方法：温度测量 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"设备各部件散发的温度","technique_zh":"方法：温度测量"},{"_id":"6a5e78454cc76d93cba3b405","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Odporność urządzenia na przelanie cieczy","methodology_en":"Resistance of the device to liquid spillage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność urządzenia na przelanie cieczy","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Odporność urządzenia na przelanie cieczy PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Odpornosc urzadzenia na przelanie cieczy PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":192,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Resistance of the device to liquid spillage PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 设备耐液体溢洒性 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"设备耐液体溢洒性"},{"_id":"6a5e78454cc76d93cba3b406","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość mechaniczna urządzeń","methodology_en":"Mechanical strength of equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","techniques":["Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy"],"technique_en":"Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wytrzymalosc mechaniczna urzadzen\nMetoda: proba nacisku, proba udaru, spadek swobodny, uderzenie w wystajacy prog 40 mm, zjazd z uskoku 40 mm, uderzenie urzadzenia o framuge drzwi, odksztalcenie obudowy PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":193,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Mechanical strength of equipment Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 设备的机械强度 方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"设备的机械强度","technique_zh":"方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形"},{"_id":"6a5e78454cc76d93cba3b407","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość elementów wykonawczych regulatorów urządzeń","methodology_en":"Strength of actuating parts of equipment controls","parameters":[{"name":"Zakres","range":"moment skręcający"},{"name":"Zakres","range":"(0,001 - 6) Nm"}],"parameters_en":[{"name":"Range","range":"moment skręcający"},{"name":"Range","range":"(0,001 - 6) Nm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wytrzymalosc elementow wykonawczych regulatorow urzadzen\nZakres:\nZakres moment skrecajacy\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezposredni PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":194,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Strength of actuating parts of equipment controls Method: direct measurement Range Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"moment skręcający"},{"name":"范围","range":"(0,001 - 6) Nm"}],"search_zh":"医用电气设备 设备调节器执行元件的强度 方法：直接测量 范围 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备","methodology_zh":"设备调节器执行元件的强度"},{"_id":"6a5e78454cc76d93cba3b408","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość mechaniczna sterowników nożnych","methodology_en":"Mechanical strength of foot controls","parameters":[{"name":"Zakres","range":"(0,1 - 1350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1350) N"}],"technique":"Metoda: próba nacisku","techniques":["Metoda: próba nacisku"],"technique_en":"Method: compression test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wytrzymalosc mechaniczna sterownikow noznych\nZakres (0,1 - 1350) N\nMetoda: proba nacisku PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":195,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Mechanical strength of foot controls Method: compression test Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,1 - 1350) N"}],"search_zh":"医用电气设备 脚踏控制器的机械强度 方法：加压试验 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","technique_zh":"方法：加压试验","methodology_zh":"脚踏控制器的机械强度"},{"_id":"6a5e78454cc76d93cba3b409","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wytrzymałość elektryczna transformatorów","methodology_en":"Electric strength of transformers","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wytrzymalosc elektryczna transformatorow\nZakres (0,5 - 4,0) kV PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":196,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Electric strength of transformers Range PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 变压器的介电强度 范围 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备","methodology_zh":"变压器的介电强度"},{"_id":"6a5e78454cc76d93cba3b40a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne","test_object_en":"Medical electrical equipment","methodology":"Wymiary zapewniające bezpieczeństwo użytkowania:","methodology_en":"Dimensions ensuring safety in use:","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar wielkości geometrycznych i badania próbnikami – badanie palcem i hakiem probierczym","techniques":["Metoda: pomiar wielkości geometrycznych i badania próbnikami – badanie palcem i hakiem probierczym"],"technique_en":"Method: measurement of geometric quantities and testing with probes – testing with a test finger and test hook","computed":[],"computed_en":[],"activity":"Wymiary zapewniające bezpieczeństwo użytkowania:\nMetoda: pomiar wielkości geometrycznych i badania próbnikami – badanie palcem i hakiem probierczym","reference":"PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","norm_bases":["PN-EN 60601-1:2011","PN-EN 60601-1:2011/A1:2014-02","PN-EN 60601-1:2011/A12:2014-12","PN-EN 60601-1:2011/A2:2022-03","PN-EN 60601-1:2011/A13:2025-01","PN-EN 60601-1-6:2010","PN-EN 60601-1-6:2010/A1:2015-09","PN-EN 60601-1-11:2015-09","PN-EN 60601-1-11:2015-09/A1:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne Wymiary zapewniające bezpieczeństwo użytkowania:\nMetoda: pomiar wielkości geometrycznych i badania próbnikami – badanie palcem i hakiem probierczym PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12 Medyczne urzadzenia elektryczne Wymiary zapewniajace bezpieczenstwo uzytkowania:\nMetoda: pomiar wielkosci geometrycznych i badania probnikami – badanie palcem i hakiem probierczym PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","categories":["other"],"row_index":197,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment Dimensions ensuring safety in use: Method: measurement of geometric quantities and testing with probes – testing with a test finger and test hook PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","search_zh":"医用电气设备 PN-EN 60601-1:2011 | PN-EN 60601-1:2011/A1:2014-02 | PN-EN 60601-1:2011/A12:2014-12 | PN-EN 60601-1:2011/A2:2022-03 | PN-EN 60601-1:2011/A13:2025-01 | PN-EN 60601-1-6:2010 | PN-EN 60601-1-6:2010/A1:2015-09 | PN-EN 60601-1-11:2015-09 | PN-EN 60601-1-11:2015-09/A1:2021-12","test_object_zh":"医用电气设备"},{"_id":"6a5e78454cc76d93cba3b40b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Moc pobierana","methodology_en":"Power consumption","parameters":[{"name":"Zakres","range":"(0,001 - 9000,0) W"},{"name":"Zakres","range":"(0,001 - 9000,0) VA"}],"parameters_en":[{"name":"Range","range":"(0,001 - 9000,0) W"},{"name":"Range","range":"(0,001 - 9000,0) VA"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":198,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Power consumption Method: direct measurement Range Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,001 - 9000,0) W"},{"name":"范围","range":"(0,001 - 9000,0) VA"}],"search_zh":"医用电气设备 — 儿童医用床 消耗功率 方法：直接测量 范围 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"消耗功率"},{"_id":"6a5e78454cc76d93cba3b40c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Napięcie","methodology_en":"Voltage","parameters":[{"name":"Zakres","range":"(0,001 - 900) V"}],"parameters_en":[{"name":"Range","range":"(0,001 - 900) V"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Napiecie\nZakres (0,001 - 900) V\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":199,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Voltage Method: direct measurement Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,001 - 900) V"}],"search_zh":"医用电气设备 — 儿童医用床 电压 方法：直接测量 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"电压"},{"_id":"6a5e78454cc76d93cba3b40d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Prąd","methodology_en":"Current","parameters":[{"name":"Zakres","range":"(0,001 - 30) A"}],"parameters_en":[{"name":"Range","range":"(0,001 - 30) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Prad\nZakres (0,001 - 30) A\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":200,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Current Method: direct measurement Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,001 - 30) A"}],"search_zh":"医用电气设备 — 儿童医用床 电流 方法：直接测量 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"电流"},{"_id":"6a5e78454cc76d93cba3b40e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Czytelność oznakowania","methodology_en":"Legibility of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Pomiar bezpośredni","techniques":["Metoda: Pomiar bezpośredni"],"technique_en":"Method: Direct measurement","computed":[],"computed_en":[],"activity":"Czytelność oznakowania\nMetoda: Pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Czytelność oznakowania\nMetoda: Pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Czytelnosc oznakowania\nMetoda: Pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":201,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Legibility of marking Method: Direct measurement PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 标识的清晰度 方法：直接测量 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"标识的清晰度","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b40f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Trwałość oznakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Próba trwałości oznakowania (woda, alkohol)","techniques":["Metoda: Próba trwałości oznakowania (woda, alkohol)"],"technique_en":"Method: Marking durability test (water, alcohol)","computed":[],"computed_en":[],"activity":"Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol)","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol) PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Trwalosc oznakowania\nMetoda: Proba trwalosci oznakowania (woda, alkohol) PN-EN 50637:2018-04","categories":["water"],"row_index":202,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Durability of marking Method: Marking durability test (water, alcohol) PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 标识耐久性 方法：标识耐久性试验（水、酒精） PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"标识耐久性","technique_zh":"方法：标识耐久性试验（水、酒精）"},{"_id":"6a5e78454cc76d93cba3b410","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Impedancja obwodu ochronnego prądem min. 25 A","methodology_en":"Impedance of the protective circuit at a current of min. 25 A","parameters":[{"name":"Zakres","range":"(0,001 - 2,1) Ω"}],"parameters_en":[{"name":"Range","range":"(0,001 - 2,1) Ω"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Impedancja obwodu ochronnego prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Impedancja obwodu ochronnego prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Impedancja obwodu ochronnego pradem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":203,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Impedance of the protective circuit at a current of min. 25 A Method: direct measurement Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,001 - 2,1) Ω"}],"search_zh":"医用电气设备 — 儿童医用床 方法：直接测量 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床"},{"_id":"6a5e78454cc76d93cba3b411","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Prądy upływu, prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)","methodology_en":"Leakage currents, earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part)","parameters":[{"name":"Zakres","range":"(0 - 10) A"}],"parameters_en":[{"name":"Range","range":"(0 - 10) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prądy upływu, prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Prądy upływu, prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Prady uplywu, prad uplywu uziomowy, prad uplywu obudowy, prad uplywu pacjenta, prad pomocniczy pacjenta, prad uplywu pacjenta (napiecie sieciowe na czesci aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":204,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Leakage currents, earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part) Method: direct measurement Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0 - 10) A"}],"search_zh":"医用电气设备 — 儿童医用床 方法：直接测量 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床"},{"_id":"6a5e78454cc76d93cba3b412","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wytrzymalosc elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN 50637:2018-04","categories":["construction"],"row_index":205,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Dielectric strength of the insulation Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 — 儿童医用床 绝缘介电强度 范围 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"绝缘介电强度"},{"_id":"6a5e78454cc76d93cba3b413","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Odkształcenie obudowy przy próbie odporności na ciepło","methodology_en":"Deformation of the enclosure in the heat resistance test","parameters":[],"parameters_en":[],"technique":"Metoda: Próba wciskania kulki","techniques":["Metoda: Próba wciskania kulki"],"technique_en":"Method: Ball pressure test","computed":[],"computed_en":[],"activity":"Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Odksztalcenie obudowy przy probie odpornosci na cieplo\nMetoda: Proba wciskania kulki PN-EN 50637:2018-04","categories":["other"],"row_index":206,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Deformation of the enclosure in the heat resistance test Method: Ball pressure test PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 耐热试验时外壳的变形 方法：球压试验 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"耐热试验时外壳的变形","technique_zh":"方法：球压试验"},{"_id":"6a5e78454cc76d93cba3b414","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Odstępy izolacyjne powierzchniowe i powietrzne","methodology_en":"Creepage distances and clearances","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Odstepy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["construction"],"row_index":207,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Creepage distances and clearances Method: direct measurement PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 爬电距离与电气间隙 方法：直接测量 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"爬电距离与电气间隙"},{"_id":"6a5e78454cc76d93cba3b415","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Szczeliny w ochronie przed zagrożeniami mechanicznymi","methodology_en":"Gaps in protection against mechanical hazards","parameters":[{"name":"Zakres","range":"(0,1 - 1000) mm"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1000) mm"}],"technique":"Metoda: pomiar wielkości liniowych","techniques":["Metoda: pomiar wielkości liniowych"],"technique_en":"Method: measurement of linear dimensions","computed":[],"computed_en":[],"activity":"Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Szczeliny w ochronie przed zagrozeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkosci liniowych PN-EN 50637:2018-04","categories":["other"],"row_index":208,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Gaps in protection against mechanical hazards Method: measurement of linear dimensions Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,1 - 1000) mm"}],"search_zh":"医用电气设备 — 儿童医用床 机械危险防护中的开口 方法：线性量测量 范围 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"机械危险防护中的开口","technique_zh":"方法：线性量测量"},{"_id":"6a5e78454cc76d93cba3b416","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych","methodology_en":"Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces","parameters":[{"name":"Zakres","range":"(0 - 30)°, siła (0,1 - 1100) N,"},{"name":"obciążenie","range":"(0,1 - 2200) N"}],"parameters_en":[{"name":"Range","range":"(0 - 30)°, siła (0,1 - 1100) N,"},{"name":"load","range":"(0,1 - 2200) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres:\nZakres (0 - 30)°, siła (0,1 - 1100) N,\nobciążenie (0,1 - 2200) N\nMetoda: próba stateczności","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres:\nZakres (0 - 30)°, siła (0,1 - 1100) N,\nobciążenie (0,1 - 2200) N\nMetoda: próba stateczności PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Niestabilnosc urzadzenia w pozycji transportowej, poza transportem oraz w wyniku dzialania sil poziomych i pionowych\nZakres:\nZakres (0 - 30)°, sila (0,1 - 1100) N,\nobciazenie (0,1 - 2200) N\nMetoda: proba statecznosci PN-EN 50637:2018-04","categories":["other"],"row_index":209,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces Method: stability test Range load PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0 - 30)°, siła (0,1 - 1100) N,"},{"name":"荷载","range":"(0,1 - 2200) N"}],"search_zh":"医用电气设备 — 儿童医用床 设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性 方法：稳定性试验 范围 荷载 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b417","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu","methodology_en":"Instability of the device during transport and other than during transport","parameters":[{"name":"kąt","range":"(0 - 30)°"},{"name":"siła","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"angle","range":"(0 - 30)°"},{"name":"force","range":"(0,1 - 350) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Niestabilnosc urzadzenia podczas transportu oraz z wyjatkiem transportu\nZakres:\nkat (0 - 30)°\nsila (0,1 - 350) N\nMetoda: proba statecznosci PN-EN 50637:2018-04","categories":["other"],"row_index":210,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Instability of the device during transport and other than during transport Method: stability test angle force PN-EN 50637:2018-04","parameters_zh":[{"name":"角度","range":"(0 - 30)°"},{"name":"力","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 — 儿童医用床 设备在运输过程中及运输以外情况下的不稳定性 方法：稳定性试验 角度 力 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输过程中及运输以外情况下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b418","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Siła umożliwiająca wprawienie w ruch urządzenia","methodology_en":"Force required to set the equipment in motion","parameters":[{"name":"Zakres","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 350) N"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Sila umozliwiajaca wprawienie w ruch urzadzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":211,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Force required to set the equipment in motion Method: direct measurement Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 — 儿童医用床 使设备启动所需的力 方法：直接测量 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"使设备启动所需的力"},{"_id":"6a5e78454cc76d93cba3b419","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Zdolność urządzenia do przejazdu przez próg","methodology_en":"Ability of the device to pass over a threshold","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność urządzenia do przejazdu przez próg","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Zdolność urządzenia do przejazdu przez próg PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Zdolnosc urzadzenia do przejazdu przez prog PN-EN 50637:2018-04","categories":["other"],"row_index":212,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Ability of the device to pass over a threshold PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 设备越过门槛的通过能力 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"设备越过门槛的通过能力"},{"_id":"6a5e78454cc76d93cba3b41a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń","methodology_en":"Mechanical strength of handles and other means for carrying equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wytrzymalosc mechaniczna uchwytow i innych srodkow do przenoszenia urzadzen\nMetoda: proba obciazenia PN-EN 50637:2018-04","categories":["other"],"row_index":213,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Mechanical strength of handles and other means for carrying equipment Method: load test PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 把手及其他搬运设备用件的机械强度 方法：荷载试验 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","technique_zh":"方法：荷载试验","methodology_zh":"把手及其他搬运设备用件的机械强度"},{"_id":"6a5e78454cc76d93cba3b41b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wytrzymałość mechaniczna systemów podtrzymywania","methodology_en":"Mechanical strength of support systems","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wytrzymalosc mechaniczna systemow podtrzymywania\nMetoda: proba obciazenia PN-EN 50637:2018-04","categories":["other"],"row_index":214,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Mechanical strength of support systems Method: load test PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 支撑系统的机械强度 方法：荷载试验 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","technique_zh":"方法：荷载试验","methodology_zh":"支撑系统的机械强度"},{"_id":"6a5e78454cc76d93cba3b41c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(-50 - 800)°C"}],"parameters_en":[{"name":"Range","range":"(-50 - 800)°C"}],"technique":"Metoda: Pomiar temperatury","techniques":["Metoda: Pomiar temperatury"],"technique_en":"Method: Temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Temperatura wydzielana przez różne części urządzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury PN-EN 50637:2018-04","categories":["other"],"row_index":215,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Temperature emitted by various parts of the appliance Method: Temperature measurement Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(-50 - 800)°C"}],"search_zh":"医用电气设备 — 儿童医用床 设备各部件散发的温度 方法：温度测量 范围 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"设备各部件散发的温度","technique_zh":"方法：温度测量"},{"_id":"6a5e78454cc76d93cba3b41d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Odporność urządzenia na przelanie cieczy","methodology_en":"Resistance of the device to liquid spillage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność urządzenia na przelanie cieczy","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Odporność urządzenia na przelanie cieczy PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Odpornosc urzadzenia na przelanie cieczy PN-EN 50637:2018-04","categories":["other"],"row_index":216,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Resistance of the device to liquid spillage PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 设备耐液体溢洒性 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"设备耐液体溢洒性"},{"_id":"6a5e78454cc76d93cba3b41e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wytrzymałość mechaniczna urządzeń","methodology_en":"Mechanical strength of equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","techniques":["Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy"],"technique_en":"Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wytrzymalosc mechaniczna urzadzen\nMetoda: proba nacisku, proba udaru, spadek swobodny, uderzenie w wystajacy prog 40 mm, zjazd z uskoku 40 mm, uderzenie urzadzenia o framuge drzwi, odksztalcenie obudowy PN-EN 50637:2018-04","categories":["other"],"row_index":217,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Mechanical strength of equipment Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation PN-EN 50637:2018-04","search_zh":"医用电气设备 — 儿童医用床 设备的机械强度 方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"设备的机械强度","technique_zh":"方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形"},{"_id":"6a5e78454cc76d93cba3b41f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wytrzymałość elementów wykonawczych regulatorów urządzeń","methodology_en":"Strength of actuating parts of equipment controls","parameters":[{"name":"Zakres","range":"moment skręcający"},{"name":"Zakres","range":"(0,001 - 6) Nm"}],"parameters_en":[{"name":"Range","range":"moment skręcający"},{"name":"Range","range":"(0,001 - 6) Nm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wytrzymalosc elementow wykonawczych regulatorow urzadzen\nZakres:\nZakres moment skrecajacy\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":218,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Strength of actuating parts of equipment controls Method: direct measurement Range Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"moment skręcający"},{"name":"范围","range":"(0,001 - 6) Nm"}],"search_zh":"医用电气设备 — 儿童医用床 设备调节器执行元件的强度 方法：直接测量 范围 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"设备调节器执行元件的强度"},{"_id":"6a5e78454cc76d93cba3b420","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wytrzymałość mechaniczna sterowników nożnych","methodology_en":"Mechanical strength of foot controls","parameters":[{"name":"Zakres","range":"(0,1 - 1350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1350) N"}],"technique":"Metoda: próba nacisku","techniques":["Metoda: próba nacisku"],"technique_en":"Method: compression test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wytrzymalosc mechaniczna sterownikow noznych\nZakres (0,1 - 1350) N\nMetoda: proba nacisku PN-EN 50637:2018-04","categories":["other"],"row_index":219,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Mechanical strength of foot controls Method: compression test Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,1 - 1350) N"}],"search_zh":"医用电气设备 — 儿童医用床 脚踏控制器的机械强度 方法：加压试验 范围 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","technique_zh":"方法：加压试验","methodology_zh":"脚踏控制器的机械强度"},{"_id":"6a5e78454cc76d93cba3b421","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wytrzymałość elektryczna transformatorów","methodology_en":"Electric strength of transformers","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wytrzymalosc elektryczna transformatorow\nZakres (0,5 - 4,0) kV PN-EN 50637:2018-04","categories":["other"],"row_index":220,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Electric strength of transformers Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 — 儿童医用床 变压器的介电强度 范围 PN-EN 50637:2018-04","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"变压器的介电强度"},{"_id":"6a5e78454cc76d93cba3b422","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci","test_object_en":"Medical electrical equipment – medical beds for children","methodology":"Wielkości kątowe","methodology_en":"Angular quantities","parameters":[{"name":"Zakres","range":"(0 - 360)°"}],"parameters_en":[{"name":"Range","range":"(0 - 360)°"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wielkości kątowe\nZakres (0 - 360)°\nMetoda: pomiar bezpośredni","reference":"PN-EN 50637:2018-04","norm_bases":["PN-EN 50637:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne dla dzieci Wielkości kątowe\nZakres (0 - 360)°\nMetoda: pomiar bezpośredni PN-EN 50637:2018-04 Medyczne urzadzenia elektryczne – lozka medyczne dla dzieci Wielkosci katowe\nZakres (0 - 360)°\nMetoda: pomiar bezposredni PN-EN 50637:2018-04","categories":["other"],"row_index":221,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds for children Angular quantities Method: direct measurement Range PN-EN 50637:2018-04","parameters_zh":[{"name":"范围","range":"(0 - 360)°"}],"search_zh":"医用电气设备 — 儿童医用床 角度量 方法：直接测量 范围 PN-EN 50637:2018-04","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 儿童医用床","methodology_zh":"角度量"},{"_id":"6a5e78454cc76d93cba3b423","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Moc pobierana","methodology_en":"Power consumption","parameters":[{"name":"Zakres","range":"(0,001 - 9000,0) W"},{"name":"Zakres","range":"(0,001 - 9000,0) VA"}],"parameters_en":[{"name":"Range","range":"(0,001 - 9000,0) W"},{"name":"Range","range":"(0,001 - 9000,0) VA"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":222,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Power consumption Method: direct measurement Range Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,001 - 9000,0) W"},{"name":"范围","range":"(0,001 - 9000,0) VA"}],"search_zh":"医用电气设备 — 手术台 消耗功率 方法：直接测量 范围 范围 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"消耗功率"},{"_id":"6a5e78454cc76d93cba3b424","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Napięcie","methodology_en":"Voltage","parameters":[{"name":"Zakres","range":"(0,001 - 900) V"}],"parameters_en":[{"name":"Range","range":"(0,001 - 900) V"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Napiecie\nZakres (0,001 - 900) V\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":223,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Voltage Method: direct measurement Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,001 - 900) V"}],"search_zh":"医用电气设备 — 手术台 电压 方法：直接测量 范围 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"电压"},{"_id":"6a5e78454cc76d93cba3b425","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Prąd","methodology_en":"Current","parameters":[{"name":"Zakres","range":"(0,001 - 30) A"}],"parameters_en":[{"name":"Range","range":"(0,001 - 30) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Prad\nZakres (0,001 - 30) A\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":224,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Current Method: direct measurement Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,001 - 30) A"}],"search_zh":"医用电气设备 — 手术台 电流 方法：直接测量 范围 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"电流"},{"_id":"6a5e78454cc76d93cba3b426","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Czytelność oznakowania","methodology_en":"Legibility of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Pomiar bezpośredni","techniques":["Metoda: Pomiar bezpośredni"],"technique_en":"Method: Direct measurement","computed":[],"computed_en":[],"activity":"Czytelność oznakowania\nMetoda: Pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Czytelność oznakowania\nMetoda: Pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Czytelnosc oznakowania\nMetoda: Pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":225,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Legibility of marking Method: Direct measurement PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 标识的清晰度 方法：直接测量 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"标识的清晰度","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b427","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Trwałość oznakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Próba trwałości oznakowania (woda, alkohol)","techniques":["Metoda: Próba trwałości oznakowania (woda, alkohol)"],"technique_en":"Method: Marking durability test (water, alcohol)","computed":[],"computed_en":[],"activity":"Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol)","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol) PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Trwalosc oznakowania\nMetoda: Proba trwalosci oznakowania (woda, alkohol) PN-EN IEC 60601-2-46:2025-03","categories":["water"],"row_index":226,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Durability of marking Method: Marking durability test (water, alcohol) PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 标识耐久性 方法：标识耐久性试验（水、酒精） PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"标识耐久性","technique_zh":"方法：标识耐久性试验（水、酒精）"},{"_id":"6a5e78454cc76d93cba3b428","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Impedancja obwodu ochronnego prądem min. 25 A","methodology_en":"Impedance of the protective circuit at a current of min. 25 A","parameters":[{"name":"Zakres","range":"(0,001 - 2,1) Ω"}],"parameters_en":[{"name":"Range","range":"(0,001 - 2,1) Ω"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Impedancja obwodu ochronnego prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Impedancja obwodu ochronnego prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Impedancja obwodu ochronnego pradem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":227,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Impedance of the protective circuit at a current of min. 25 A Method: direct measurement Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,001 - 2,1) Ω"}],"search_zh":"医用电气设备 — 手术台 方法：直接测量 范围 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台"},{"_id":"6a5e78454cc76d93cba3b429","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Prądy upływu prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)","methodology_en":"Leakage currents earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part)","parameters":[{"name":"Zakres","range":"(0 - 10) A"}],"parameters_en":[{"name":"Range","range":"(0 - 10) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prądy upływu prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Prądy upływu prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Prady uplywu prad uplywu uziomowy, prad uplywu obudowy, prad uplywu pacjenta, prad pomocniczy pacjenta, prad uplywu pacjenta (napiecie sieciowe na czesci aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":228,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Leakage currents earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part) Method: direct measurement Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0 - 10) A"}],"search_zh":"医用电气设备 — 手术台 方法：直接测量 范围 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台"},{"_id":"6a5e78454cc76d93cba3b42a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Wytrzymalosc elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN IEC 60601-2-46:2025-03","categories":["construction"],"row_index":229,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Dielectric strength of the insulation Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 — 手术台 绝缘介电强度 范围 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"绝缘介电强度"},{"_id":"6a5e78454cc76d93cba3b42b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Odkształcenie obudowy przy próbie odporności na ciepło","methodology_en":"Deformation of the enclosure in the heat resistance test","parameters":[],"parameters_en":[],"technique":"Metoda: Próba wciskania kulki","techniques":["Metoda: Próba wciskania kulki"],"technique_en":"Method: Ball pressure test","computed":[],"computed_en":[],"activity":"Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Odksztalcenie obudowy przy probie odpornosci na cieplo\nMetoda: Proba wciskania kulki PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":230,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Deformation of the enclosure in the heat resistance test Method: Ball pressure test PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 耐热试验时外壳的变形 方法：球压试验 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"耐热试验时外壳的变形","technique_zh":"方法：球压试验"},{"_id":"6a5e78454cc76d93cba3b42c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Odstępy izolacyjne powierzchniowe i powietrzne","methodology_en":"Creepage distances and clearances","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Odstepy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["construction"],"row_index":231,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Creepage distances and clearances Method: direct measurement PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 爬电距离与电气间隙 方法：直接测量 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"爬电距离与电气间隙"},{"_id":"6a5e78454cc76d93cba3b42d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)","methodology_en":"Insulation of the mains supply cord (cord anchorage and bend protection)","parameters":[{"name":"siła","range":"(0,1 - 100) N, moment"},{"name":"skręcający","range":"(0,001 - 0,35) Nm"}],"parameters_en":[{"name":"force","range":"(0,1 - 100) N, moment"},{"name":"torsional","range":"(0,001 - 0,35) Nm"}],"technique":"Metoda: próba obciążenia i próba skręcania","techniques":["Metoda: próba obciążenia i próba skręcania"],"technique_en":"Method: load test and torsion test","computed":[],"computed_en":[],"activity":"Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)\nZakres:\nsiła (0,1 - 100) N, moment\nskręcający (0,001 - 0,35) Nm\nMetoda: próba obciążenia i próba skręcania","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)\nZakres:\nsiła (0,1 - 100) N, moment\nskręcający (0,001 - 0,35) Nm\nMetoda: próba obciążenia i próba skręcania PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Izolacja przewodu zasilania sieciowego (odciazka i odgietka przewodu)\nZakres:\nsila (0,1 - 100) N, moment\nskrecajacy (0,001 - 0,35) Nm\nMetoda: proba obciazenia i proba skrecania PN-EN IEC 60601-2-46:2025-03","categories":["construction"],"row_index":232,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Insulation of the mains supply cord (cord anchorage and bend protection) Method: load test and torsion test force torsional PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"力","range":"(0,1 - 100) N, moment"},{"name":"skręcający","range":"(0,001 - 0,35) Nm"}],"search_zh":"医用电气设备 — 手术台 力 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台"},{"_id":"6a5e78454cc76d93cba3b42e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Szczeliny w ochronie przed zagrożeniami mechanicznymi","methodology_en":"Gaps in protection against mechanical hazards","parameters":[{"name":"Zakres","range":"(0,1 - 1000) mm"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1000) mm"}],"technique":"Metoda: pomiar wielkości liniowych","techniques":["Metoda: pomiar wielkości liniowych"],"technique_en":"Method: measurement of linear dimensions","computed":[],"computed_en":[],"activity":"Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Szczeliny w ochronie przed zagrozeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkosci liniowych PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":233,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Gaps in protection against mechanical hazards Method: measurement of linear dimensions Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,1 - 1000) mm"}],"search_zh":"医用电气设备 — 手术台 机械危险防护中的开口 方法：线性量测量 范围 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"机械危险防护中的开口","technique_zh":"方法：线性量测量"},{"_id":"6a5e78454cc76d93cba3b42f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych","methodology_en":"Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces","parameters":[{"name":"Zakres","range":"(0 - 30)°, siła (0,1 - 800) N"}],"parameters_en":[{"name":"Range","range":"(0 - 30)°, siła (0,1 - 800) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres (0 - 30)°, siła (0,1 - 800) N\nMetoda: próba stateczności","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres (0 - 30)°, siła (0,1 - 800) N\nMetoda: próba stateczności PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Niestabilnosc urzadzenia w pozycji transportowej, poza transportem oraz w wyniku dzialania sil poziomych i pionowych\nZakres (0 - 30)°, sila (0,1 - 800) N\nMetoda: proba statecznosci PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":234,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces Method: stability test Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0 - 30)°, siła (0,1 - 800) N"}],"search_zh":"医用电气设备 — 手术台 设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性 方法：稳定性试验 范围 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b430","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu","methodology_en":"Instability of the device during transport and other than during transport","parameters":[{"name":"kąt","range":"(0 - 30)°"},{"name":"siła","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"angle","range":"(0 - 30)°"},{"name":"force","range":"(0,1 - 350) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Niestabilnosc urzadzenia podczas transportu oraz z wyjatkiem transportu\nZakres:\nkat (0 - 30)°\nsila (0,1 - 350) N\nMetoda: proba statecznosci PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":235,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Instability of the device during transport and other than during transport Method: stability test angle force PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"角度","range":"(0 - 30)°"},{"name":"力","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 — 手术台 设备在运输过程中及运输以外情况下的不稳定性 方法：稳定性试验 角度 力 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输过程中及运输以外情况下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b431","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Siła umożliwiająca wprawienie w ruch urządzenia","methodology_en":"Force required to set the equipment in motion","parameters":[{"name":"Zakres","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 350) N"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Sila umozliwiajaca wprawienie w ruch urzadzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":236,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Force required to set the equipment in motion Method: direct measurement Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 — 手术台 使设备启动所需的力 方法：直接测量 范围 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"使设备启动所需的力"},{"_id":"6a5e78454cc76d93cba3b432","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Zdolność urządzenia do przejazdu przez próg","methodology_en":"Ability of the device to pass over a threshold","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność urządzenia do przejazdu przez próg","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Zdolność urządzenia do przejazdu przez próg PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Zdolnosc urzadzenia do przejazdu przez prog PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":237,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Ability of the device to pass over a threshold PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 设备越过门槛的通过能力 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"设备越过门槛的通过能力"},{"_id":"6a5e78454cc76d93cba3b433","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń","methodology_en":"Mechanical strength of handles and other means for carrying equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Wytrzymalosc mechaniczna uchwytow i innych srodkow do przenoszenia urzadzen\nMetoda: proba obciazenia PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":238,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Mechanical strength of handles and other means for carrying equipment Method: load test PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 把手及其他搬运设备用件的机械强度 方法：荷载试验 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","technique_zh":"方法：荷载试验","methodology_zh":"把手及其他搬运设备用件的机械强度"},{"_id":"6a5e78454cc76d93cba3b434","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Wytrzymałość mechaniczna systemów podtrzymywania","methodology_en":"Mechanical strength of support systems","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Wytrzymalosc mechaniczna systemow podtrzymywania\nMetoda: proba obciazenia PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":239,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Mechanical strength of support systems Method: load test PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 支撑系统的机械强度 方法：荷载试验 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","technique_zh":"方法：荷载试验","methodology_zh":"支撑系统的机械强度"},{"_id":"6a5e78454cc76d93cba3b435","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(od -50 do 800)°C"}],"parameters_en":[{"name":"Range","range":"(od -50 do 800)°C"}],"technique":"Metoda: Pomiar temperatury","techniques":["Metoda: Pomiar temperatury"],"technique_en":"Method: Temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do 800)°C\nMetoda: Pomiar temperatury","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Temperatura wydzielana przez różne części urządzenia\nZakres (od -50 do 800)°C\nMetoda: Pomiar temperatury PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (od -50 do 800)°C\nMetoda: Pomiar temperatury PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":240,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Temperature emitted by various parts of the appliance Method: Temperature measurement Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(od -50 do 800)°C"}],"search_zh":"医用电气设备 — 手术台 设备各部件散发的温度 方法：温度测量 范围 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"设备各部件散发的温度","technique_zh":"方法：温度测量"},{"_id":"6a5e78454cc76d93cba3b436","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Odporność urządzenia na przelanie cieczy","methodology_en":"Resistance of the device to liquid spillage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność urządzenia na przelanie cieczy","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Odporność urządzenia na przelanie cieczy PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Odpornosc urzadzenia na przelanie cieczy PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":241,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Resistance of the device to liquid spillage PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 设备耐液体溢洒性 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"设备耐液体溢洒性"},{"_id":"6a5e78454cc76d93cba3b437","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Wytrzymałość mechaniczna urządzeń","methodology_en":"Mechanical strength of equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","techniques":["Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy"],"technique_en":"Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Wytrzymalosc mechaniczna urzadzen\nMetoda: proba nacisku, proba udaru, spadek swobodny, uderzenie w wystajacy prog 40 mm, zjazd z uskoku 40 mm, uderzenie urzadzenia o framuge drzwi, odksztalcenie obudowy PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":242,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Mechanical strength of equipment Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation PN-EN IEC 60601-2-46:2025-03","search_zh":"医用电气设备 — 手术台 设备的机械强度 方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"设备的机械强度","technique_zh":"方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形"},{"_id":"6a5e78454cc76d93cba3b438","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Wytrzymałość elementów wykonawczych regulatorów urządzeń","methodology_en":"Strength of actuating parts of equipment controls","parameters":[{"name":"Zakres","range":"moment skręcający"},{"name":"Zakres","range":"(0,001 - 6) Nm"}],"parameters_en":[{"name":"Range","range":"moment skręcający"},{"name":"Range","range":"(0,001 - 6) Nm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Wytrzymalosc elementow wykonawczych regulatorow urzadzen\nZakres:\nZakres moment skrecajacy\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezposredni PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":243,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Strength of actuating parts of equipment controls Method: direct measurement Range Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"moment skręcający"},{"name":"范围","range":"(0,001 - 6) Nm"}],"search_zh":"医用电气设备 — 手术台 设备调节器执行元件的强度 方法：直接测量 范围 范围 PN-EN IEC 60601-2-46:2025-03","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"设备调节器执行元件的强度"},{"_id":"6a5e78454cc76d93cba3b439","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Wytrzymałość mechaniczna sterowników nożnych","methodology_en":"Mechanical strength of foot controls","parameters":[{"name":"Zakres","range":"(0,1 - 1350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1350) N"}],"technique":"Metoda: próba nacisku","techniques":["Metoda: próba nacisku"],"technique_en":"Method: compression test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Wytrzymalosc mechaniczna sterownikow noznych\nZakres (0,1 - 1350) N\nMetoda: proba nacisku PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":244,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Mechanical strength of foot controls Method: compression test Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,1 - 1350) N"}],"search_zh":"医用电气设备 — 手术台 脚踏控制器的机械强度 方法：加压试验 范围 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","technique_zh":"方法：加压试验","methodology_zh":"脚踏控制器的机械强度"},{"_id":"6a5e78454cc76d93cba3b43a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – stoły operacyjne","test_object_en":"Medical electrical equipment – operating tables","methodology":"Wytrzymałość elektryczna transformatorów","methodology_en":"Electric strength of transformers","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV","reference":"PN-EN IEC 60601-2-46:2025-03","norm_bases":["PN-EN IEC 60601-2-46:2025-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – stoły operacyjne Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV PN-EN IEC 60601-2-46:2025-03 Medyczne urzadzenia elektryczne – stoly operacyjne Wytrzymalosc elektryczna transformatorow\nZakres (0,5 - 4,0) kV PN-EN IEC 60601-2-46:2025-03","categories":["other"],"row_index":245,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – operating tables Electric strength of transformers Range PN-EN IEC 60601-2-46:2025-03","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 — 手术台 变压器的介电强度 范围 PN-EN IEC 60601-2-46:2025-03","test_object_zh":"医用电气设备 — 手术台","methodology_zh":"变压器的介电强度"},{"_id":"6a5e78454cc76d93cba3b43b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Moc pobierana","methodology_en":"Power consumption","parameters":[{"name":"Zakres","range":"(0,001 - 9000,0) W"},{"name":"Zakres","range":"(0,001 - 9000,0) VA"}],"parameters_en":[{"name":"Range","range":"(0,001 - 9000,0) W"},{"name":"Range","range":"(0,001 - 9000,0) VA"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Moc pobierana\nZakres:\nZakres (0,001 - 9000,0) W\nZakres (0,001 - 9000,0) VA\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":246,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Power consumption Method: direct measurement Range Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,001 - 9000,0) W"},{"name":"范围","range":"(0,001 - 9000,0) VA"}],"search_zh":"医用电气设备 — 医用床 消耗功率 方法：直接测量 范围 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"消耗功率"},{"_id":"6a5e78454cc76d93cba3b43c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Napięcie","methodology_en":"Voltage","parameters":[{"name":"Zakres","range":"(0,001 - 900) V"}],"parameters_en":[{"name":"Range","range":"(0,001 - 900) V"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Napięcie\nZakres (0,001 - 900) V\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Napiecie\nZakres (0,001 - 900) V\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":247,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Voltage Method: direct measurement Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,001 - 900) V"}],"search_zh":"医用电气设备 — 医用床 电压 方法：直接测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"电压"},{"_id":"6a5e78454cc76d93cba3b43d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Prąd","methodology_en":"Current","parameters":[{"name":"Zakres","range":"(0,001 - 30) A"}],"parameters_en":[{"name":"Range","range":"(0,001 - 30) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Prąd\nZakres (0,001 - 30) A\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Prad\nZakres (0,001 - 30) A\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":248,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Current Method: direct measurement Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,001 - 30) A"}],"search_zh":"医用电气设备 — 医用床 电流 方法：直接测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"电流"},{"_id":"6a5e78454cc76d93cba3b43e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Czytelność oznakowania","methodology_en":"Legibility of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Pomiar bezpośredni","techniques":["Metoda: Pomiar bezpośredni"],"technique_en":"Method: Direct measurement","computed":[],"computed_en":[],"activity":"Czytelność oznakowania\nMetoda: Pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Czytelność oznakowania\nMetoda: Pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Czytelnosc oznakowania\nMetoda: Pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":249,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Legibility of marking Method: Direct measurement PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 标识的清晰度 方法：直接测量 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"标识的清晰度","technique_zh":"方法：直接测量"},{"_id":"6a5e78454cc76d93cba3b43f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Trwałość oznakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":"Metoda: Próba trwałości oznakowania (woda, alkohol)","techniques":["Metoda: Próba trwałości oznakowania (woda, alkohol)"],"technique_en":"Method: Marking durability test (water, alcohol)","computed":[],"computed_en":[],"activity":"Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol)","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Trwałość oznakowania\nMetoda: Próba trwałości oznakowania (woda, alkohol) PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Trwalosc oznakowania\nMetoda: Proba trwalosci oznakowania (woda, alkohol) PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["water"],"row_index":250,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Durability of marking Method: Marking durability test (water, alcohol) PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 标识耐久性 方法：标识耐久性试验（水、酒精） PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"标识耐久性","technique_zh":"方法：标识耐久性试验（水、酒精）"},{"_id":"6a5e78454cc76d93cba3b440","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Impedancja obwodu ochronnego + prądem min. 25 A","methodology_en":"Impedance of the protective circuit + with a current of min. 25 A","parameters":[{"name":"Zakres","range":"(0,001 - 2,1) Ω"}],"parameters_en":[{"name":"Range","range":"(0,001 - 2,1) Ω"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Impedancja obwodu ochronnego + prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Impedancja obwodu ochronnego + prądem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Impedancja obwodu ochronnego + pradem min. 25 A\nZakres (0,001 - 2,1) Ω\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":251,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Impedance of the protective circuit + with a current of min. 25 A Method: direct measurement Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,001 - 2,1) Ω"}],"search_zh":"医用电气设备 — 医用床 方法：直接测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床"},{"_id":"6a5e78454cc76d93cba3b441","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Prądy upływu prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)","methodology_en":"Leakage currents earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part)","parameters":[{"name":"Zakres","range":"(0 - 10) A"}],"parameters_en":[{"name":"Range","range":"(0 - 10) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prądy upływu prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Prądy upływu prąd upływu uziomowy, prąd upływu obudowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Prady uplywu prad uplywu uziomowy, prad uplywu obudowy, prad uplywu pacjenta, prad pomocniczy pacjenta, prad uplywu pacjenta (napiecie sieciowe na czesci aplikacyjnej)\nZakres (0 - 10) A\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":252,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Leakage currents earth leakage current, enclosure leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part) Method: direct measurement Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0 - 10) A"}],"search_zh":"医用电气设备 — 医用床 方法：直接测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床"},{"_id":"6a5e78454cc76d93cba3b442","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wytrzymałość elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wytrzymalosc elektryczna izolacji\nZakres (0,5 - 4,0) kV PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["construction"],"row_index":253,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Dielectric strength of the insulation Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 — 医用床 绝缘介电强度 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"绝缘介电强度"},{"_id":"6a5e78454cc76d93cba3b443","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Odkształcenie obudowy przy próbie odporności na ciepło","methodology_en":"Deformation of the enclosure in the heat resistance test","parameters":[],"parameters_en":[],"technique":"Metoda: Próba wciskania kulki","techniques":["Metoda: Próba wciskania kulki"],"technique_en":"Method: Ball pressure test","computed":[],"computed_en":[],"activity":"Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: Próba wciskania kulki PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Odksztalcenie obudowy przy probie odpornosci na cieplo\nMetoda: Proba wciskania kulki PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":254,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Deformation of the enclosure in the heat resistance test Method: Ball pressure test PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 耐热试验时外壳的变形 方法：球压试验 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"耐热试验时外壳的变形","technique_zh":"方法：球压试验"},{"_id":"6a5e78454cc76d93cba3b444","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Odstępy izolacyjne powierzchniowe i powietrzne","methodology_en":"Creepage distances and clearances","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Odstepy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["construction"],"row_index":255,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Creepage distances and clearances Method: direct measurement PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 爬电距离与电气间隙 方法：直接测量 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"爬电距离与电气间隙"},{"_id":"6a5e78454cc76d93cba3b445","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)","methodology_en":"Insulation of the mains supply cord (cord anchorage and bend protection)","parameters":[{"name":"siła","range":"(0,1 - 100) N, moment"},{"name":"skręcający","range":"(0,001 - 0,35) Nm"}],"parameters_en":[{"name":"force","range":"(0,1 - 100) N, moment"},{"name":"torsional","range":"(0,001 - 0,35) Nm"}],"technique":"Metoda: próba obciążenia i próba skręcania","techniques":["Metoda: próba obciążenia i próba skręcania"],"technique_en":"Method: load test and torsion test","computed":[],"computed_en":[],"activity":"Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)\nZakres:\nsiła (0,1 - 100) N, moment\nskręcający (0,001 - 0,35) Nm\nMetoda: próba obciążenia i próba skręcania","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Izolacja przewodu zasilania sieciowego (odciążka i odgiętka przewodu)\nZakres:\nsiła (0,1 - 100) N, moment\nskręcający (0,001 - 0,35) Nm\nMetoda: próba obciążenia i próba skręcania PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Izolacja przewodu zasilania sieciowego (odciazka i odgietka przewodu)\nZakres:\nsila (0,1 - 100) N, moment\nskrecajacy (0,001 - 0,35) Nm\nMetoda: proba obciazenia i proba skrecania PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["construction"],"row_index":256,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Insulation of the mains supply cord (cord anchorage and bend protection) Method: load test and torsion test force torsional PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"力","range":"(0,1 - 100) N, moment"},{"name":"skręcający","range":"(0,001 - 0,35) Nm"}],"search_zh":"医用电气设备 — 医用床 力 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床"},{"_id":"6a5e78454cc76d93cba3b446","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Szczeliny w ochronie przed zagrożeniami mechanicznymi","methodology_en":"Gaps in protection against mechanical hazards","parameters":[{"name":"Zakres","range":"(0,1 - 1000) mm"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1000) mm"}],"technique":"Metoda: pomiar wielkości liniowych","techniques":["Metoda: pomiar wielkości liniowych"],"technique_en":"Method: measurement of linear dimensions","computed":[],"computed_en":[],"activity":"Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Szczeliny w ochronie przed zagrożeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkości liniowych PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Szczeliny w ochronie przed zagrozeniami mechanicznymi\nZakres (0,1 - 1000) mm\nMetoda: pomiar wielkosci liniowych PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":257,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Gaps in protection against mechanical hazards Method: measurement of linear dimensions Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,1 - 1000) mm"}],"search_zh":"医用电气设备 — 医用床 机械危险防护中的开口 方法：线性量测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"机械危险防护中的开口","technique_zh":"方法：线性量测量"},{"_id":"6a5e78454cc76d93cba3b447","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych","methodology_en":"Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces","parameters":[{"name":"kąt","range":"(0 - 30)°,"},{"name":"siła","range":"(0,1 - 1100) N"},{"name":"obciążenie","range":"(0,1 - 2200) N"}],"parameters_en":[{"name":"angle","range":"(0 - 30)°,"},{"name":"force","range":"(0,1 - 1100) N"},{"name":"load","range":"(0,1 - 2200) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres:\nkąt (0 - 30)°,\nsiła (0,1 - 1100) N\nobciążenie (0,1 - 2200) N\nMetoda: próba stateczności","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Niestabilność urządzenia w pozycji transportowej, poza transportem oraz w wyniku działania sił poziomych i pionowych\nZakres:\nkąt (0 - 30)°,\nsiła (0,1 - 1100) N\nobciążenie (0,1 - 2200) N\nMetoda: próba stateczności PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Niestabilnosc urzadzenia w pozycji transportowej, poza transportem oraz w wyniku dzialania sil poziomych i pionowych\nZakres:\nkat (0 - 30)°,\nsila (0,1 - 1100) N\nobciazenie (0,1 - 2200) N\nMetoda: proba statecznosci PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":258,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Instability of the device in the transport position, other than during transport and as a result of horizontal and vertical forces Method: stability test angle force load PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"角度","range":"(0 - 30)°,"},{"name":"力","range":"(0,1 - 1100) N"},{"name":"荷载","range":"(0,1 - 2200) N"}],"search_zh":"医用电气设备 — 医用床 设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性 方法：稳定性试验 角度 力 荷载 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输位置、非运输状态下以及在水平与竖向力作用下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b448","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu","methodology_en":"Instability of the device during transport and other than during transport","parameters":[{"name":"kąt","range":"(0 - 30)°"},{"name":"siła","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"angle","range":"(0 - 30)°"},{"name":"force","range":"(0,1 - 350) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Niestabilność urządzenia podczas transportu oraz z wyjątkiem transportu\nZakres:\nkąt (0 - 30)°\nsiła (0,1 - 350) N\nMetoda: próba stateczności PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Niestabilnosc urzadzenia podczas transportu oraz z wyjatkiem transportu\nZakres:\nkat (0 - 30)°\nsila (0,1 - 350) N\nMetoda: proba statecznosci PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":259,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Instability of the device during transport and other than during transport Method: stability test angle force PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"角度","range":"(0 - 30)°"},{"name":"力","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 — 医用床 设备在运输过程中及运输以外情况下的不稳定性 方法：稳定性试验 角度 力 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","technique_zh":"方法：稳定性试验","methodology_zh":"设备在运输过程中及运输以外情况下的不稳定性"},{"_id":"6a5e78454cc76d93cba3b449","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Siła umożliwiająca wprawienie w ruch urządzenia","methodology_en":"Force required to set the equipment in motion","parameters":[{"name":"Zakres","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 350) N"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Sila umozliwiajaca wprawienie w ruch urzadzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":260,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Force required to set the equipment in motion Method: direct measurement Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,1 - 350) N"}],"search_zh":"医用电气设备 — 医用床 使设备启动所需的力 方法：直接测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"使设备启动所需的力"},{"_id":"6a5e78454cc76d93cba3b44a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Zdolność urządzenia do przejazdu przez próg","methodology_en":"Ability of the device to pass over a threshold","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zdolność urządzenia do przejazdu przez próg","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Zdolność urządzenia do przejazdu przez próg PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Zdolnosc urzadzenia do przejazdu przez prog PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":261,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Ability of the device to pass over a threshold PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 设备越过门槛的通过能力 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"设备越过门槛的通过能力"},{"_id":"6a5e78454cc76d93cba3b44b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń","methodology_en":"Mechanical strength of handles and other means for carrying equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wytrzymalosc mechaniczna uchwytow i innych srodkow do przenoszenia urzadzen\nMetoda: proba obciazenia PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":262,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Mechanical strength of handles and other means for carrying equipment Method: load test PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 把手及其他搬运设备用件的机械强度 方法：荷载试验 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","technique_zh":"方法：荷载试验","methodology_zh":"把手及其他搬运设备用件的机械强度"},{"_id":"6a5e78454cc76d93cba3b44c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wytrzymałość mechaniczna systemów podtrzymywania","methodology_en":"Mechanical strength of support systems","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wytrzymalosc mechaniczna systemow podtrzymywania\nMetoda: proba obciazenia PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":263,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Mechanical strength of support systems Method: load test PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 支撑系统的机械强度 方法：荷载试验 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","technique_zh":"方法：荷载试验","methodology_zh":"支撑系统的机械强度"},{"_id":"6a5e78454cc76d93cba3b44d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(-50 - 800)°C"}],"parameters_en":[{"name":"Range","range":"(-50 - 800)°C"}],"technique":"Metoda: Pomiar temperatury","techniques":["Metoda: Pomiar temperatury"],"technique_en":"Method: Temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Temperatura wydzielana przez różne części urządzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (-50 - 800)°C\nMetoda: Pomiar temperatury PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":264,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Temperature emitted by various parts of the appliance Method: Temperature measurement Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(-50 - 800)°C"}],"search_zh":"医用电气设备 — 医用床 设备各部件散发的温度 方法：温度测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"设备各部件散发的温度","technique_zh":"方法：温度测量"},{"_id":"6a5e78454cc76d93cba3b44e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Odporność urządzenia na przelanie cieczy","methodology_en":"Resistance of the device to liquid spillage","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność urządzenia na przelanie cieczy","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Odporność urządzenia na przelanie cieczy PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Odpornosc urzadzenia na przelanie cieczy PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":265,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Resistance of the device to liquid spillage PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 设备耐液体溢洒性 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"设备耐液体溢洒性"},{"_id":"6a5e78454cc76d93cba3b44f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wytrzymałość mechaniczna urządzeń","methodology_en":"Mechanical strength of equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","techniques":["Metoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy"],"technique_en":"Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wytrzymałość mechaniczna urządzeń\nMetoda: próba nacisku, próba udaru, spadek swobodny, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie urządzenia o framugę drzwi, odkształcenie obudowy PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wytrzymalosc mechaniczna urzadzen\nMetoda: proba nacisku, proba udaru, spadek swobodny, uderzenie w wystajacy prog 40 mm, zjazd z uskoku 40 mm, uderzenie urzadzenia o framuge drzwi, odksztalcenie obudowy PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":266,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Mechanical strength of equipment Method: compression test, impact test, free fall, impact against a 40 mm protruding threshold, descent from a 40 mm step, impact of the device against a door frame, housing deformation PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","search_zh":"医用电气设备 — 医用床 设备的机械强度 方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"设备的机械强度","technique_zh":"方法：加压试验、冲击试验、自由跌落、撞击 40 mm 突出门槛、驶下 40 mm 落差、设备撞击门框、外壳变形"},{"_id":"6a5e78454cc76d93cba3b450","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wytrzymałość elementów wykonawczych regulatorów urządzeń","methodology_en":"Strength of actuating parts of equipment controls","parameters":[{"name":"Zakres","range":"moment skręcający"},{"name":"Zakres","range":"(0,001 - 6) Nm"}],"parameters_en":[{"name":"Range","range":"moment skręcający"},{"name":"Range","range":"(0,001 - 6) Nm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wytrzymałość elementów wykonawczych regulatorów urządzeń\nZakres:\nZakres moment skręcający\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wytrzymalosc elementow wykonawczych regulatorow urzadzen\nZakres:\nZakres moment skrecajacy\nZakres (0,001 - 6) Nm\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":267,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Strength of actuating parts of equipment controls Method: direct measurement Range Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"moment skręcający"},{"name":"范围","range":"(0,001 - 6) Nm"}],"search_zh":"医用电气设备 — 医用床 设备调节器执行元件的强度 方法：直接测量 范围 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"设备调节器执行元件的强度"},{"_id":"6a5e78454cc76d93cba3b451","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wytrzymałość mechaniczna sterowników nożnych","methodology_en":"Mechanical strength of foot controls","parameters":[{"name":"Zakres","range":"(0,1 - 1350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1350) N"}],"technique":"Metoda: próba nacisku","techniques":["Metoda: próba nacisku"],"technique_en":"Method: compression test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wytrzymałość mechaniczna sterowników nożnych\nZakres (0,1 - 1350) N\nMetoda: próba nacisku PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wytrzymalosc mechaniczna sterownikow noznych\nZakres (0,1 - 1350) N\nMetoda: proba nacisku PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":268,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Mechanical strength of foot controls Method: compression test Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,1 - 1350) N"}],"search_zh":"医用电气设备 — 医用床 脚踏控制器的机械强度 方法：加压试验 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","technique_zh":"方法：加压试验","methodology_zh":"脚踏控制器的机械强度"},{"_id":"6a5e78454cc76d93cba3b452","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wytrzymałość elektryczna transformatorów","methodology_en":"Electric strength of transformers","parameters":[{"name":"Zakres","range":"(0,5 - 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 - 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wytrzymałość elektryczna transformatorów\nZakres (0,5 - 4,0) kV PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wytrzymalosc elektryczna transformatorow\nZakres (0,5 - 4,0) kV PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":269,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Electric strength of transformers Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0,5 - 4,0) kV"}],"search_zh":"医用电气设备 — 医用床 变压器的介电强度 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"变压器的介电强度"},{"_id":"6a5e78454cc76d93cba3b453","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Medyczne urządzenia elektryczne – łóżka medyczne","test_object_en":"Medical electrical equipment – medical beds","methodology":"Wielkości kątowe","methodology_en":"Angular quantities","parameters":[{"name":"Zakres","range":"(0 - 360)°"}],"parameters_en":[{"name":"Range","range":"(0 - 360)°"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wielkości kątowe\nZakres (0 - 360)°\nMetoda: pomiar bezpośredni","reference":"PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","norm_bases":["PN-EN 60601-2-52:2010","PN-EN 60601-2-52:2010/A1:2015-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Medyczne urządzenia elektryczne – łóżka medyczne Wielkości kątowe\nZakres (0 - 360)°\nMetoda: pomiar bezpośredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07 Medyczne urzadzenia elektryczne – lozka medyczne Wielkosci katowe\nZakres (0 - 360)°\nMetoda: pomiar bezposredni PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","categories":["other"],"row_index":270,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical electrical equipment – medical beds Angular quantities Method: direct measurement Range PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","parameters_zh":[{"name":"范围","range":"(0 - 360)°"}],"search_zh":"医用电气设备 — 医用床 角度量 方法：直接测量 范围 PN-EN 60601-2-52:2010 | PN-EN 60601-2-52:2010/A1:2015-07","technique_zh":"方法：直接测量","test_object_zh":"医用电气设备 — 医用床","methodology_zh":"角度量"},{"_id":"6a5e78454cc76d93cba3b454","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Wielkości liniowe","methodology_en":"Linear dimensions","parameters":[{"name":"Zakres","range":"(0,1 - 1200) mm"}],"parameters_en":[{"name":"Range","range":"(0,1 - 1200) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wielkości liniowe\nZakres (0,1 - 1200) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Wielkości liniowe\nZakres (0,1 - 1200) mm\nMetoda: pomiar bezpośredni PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Wielkosci liniowe\nZakres (0,1 - 1200) mm\nMetoda: pomiar bezposredni PN-EN ISO 10535:2022-04","categories":["other"],"row_index":271,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Linear dimensions Method: direct measurement Range PN-EN ISO 10535:2022-04","parameters_zh":[{"name":"范围","range":"(0,1 - 1200) mm"}],"search_zh":"医疗设备 － 残障人士转运升降装置 方法：直接测量 范围 PN-EN ISO 10535:2022-04","technique_zh":"方法：直接测量","test_object_zh":"医疗设备 － 残障人士转运升降装置"},{"_id":"6a5e78454cc76d93cba3b455","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Wielkości kątowe","methodology_en":"Angular quantities","parameters":[{"name":"Zakres","range":"(0 - 360)°"}],"parameters_en":[{"name":"Range","range":"(0 - 360)°"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wielkości kątowe\nZakres (0 - 360)°\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Wielkości kątowe\nZakres (0 - 360)°\nMetoda: pomiar bezpośredni PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Wielkosci katowe\nZakres (0 - 360)°\nMetoda: pomiar bezposredni PN-EN ISO 10535:2022-04","categories":["other"],"row_index":272,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Angular quantities Method: direct measurement Range PN-EN ISO 10535:2022-04","parameters_zh":[{"name":"范围","range":"(0 - 360)°"}],"search_zh":"医疗设备 － 残障人士转运升降装置 角度量 方法：直接测量 范围 PN-EN ISO 10535:2022-04","technique_zh":"方法：直接测量","test_object_zh":"医疗设备 － 残障人士转运升降装置","methodology_zh":"角度量"},{"_id":"6a5e78454cc76d93cba3b456","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Siła i moment skręcający","methodology_en":"Force and torque","parameters":[{"name":"Zakres","range":"(0,1 - 750) N oraz"},{"name":"Zakres","range":"(0,001 - 1,9) Nm"}],"parameters_en":[{"name":"Range","range":"(0,1 - 750) N oraz"},{"name":"Range","range":"(0,001 - 1,9) Nm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Siła i moment skręcający\nZakres:\nZakres (0,1 - 750) N oraz\nZakres (0,001 - 1,9) Nm\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Siła i moment skręcający\nZakres:\nZakres (0,1 - 750) N oraz\nZakres (0,001 - 1,9) Nm\nMetoda: pomiar bezpośredni PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Sila i moment skrecajacy\nZakres:\nZakres (0,1 - 750) N oraz\nZakres (0,001 - 1,9) Nm\nMetoda: pomiar bezposredni PN-EN ISO 10535:2022-04","categories":["other"],"row_index":273,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Force and torque Method: direct measurement Range Range PN-EN ISO 10535:2022-04","parameters_zh":[{"name":"范围","range":"(0,1 - 750) N oraz"},{"name":"范围","range":"(0,001 - 1,9) Nm"}],"search_zh":"医疗设备 － 残障人士转运升降装置 方法：直接测量 范围 范围 PN-EN ISO 10535:2022-04","technique_zh":"方法：直接测量","test_object_zh":"医疗设备 － 残障人士转运升降装置"},{"_id":"6a5e78454cc76d93cba3b457","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"do 18 kN"}],"parameters_en":[{"name":"Range","range":"do 18 kN"}],"technique":"Metoda: próba nacisku","techniques":["Metoda: próba nacisku"],"technique_en":"Method: compression test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres do 18 kN\nMetoda: próba nacisku","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Wytrzymałość mechaniczna\nZakres do 18 kN\nMetoda: próba nacisku PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Wytrzymalosc mechaniczna\nZakres do 18 kN\nMetoda: proba nacisku PN-EN ISO 10535:2022-04","categories":["other"],"row_index":274,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Mechanical strength Method: compression test Range PN-EN ISO 10535:2022-04","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"do 18 kN"}],"search_zh":"医疗设备 － 残障人士转运升降装置 机械强度 方法：加压试验 范围 PN-EN ISO 10535:2022-04","test_object_zh":"医疗设备 － 残障人士转运升降装置","technique_zh":"方法：加压试验"},{"_id":"6a5e78454cc76d93cba3b458","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Tempo podnoszenia i opuszczania","methodology_en":"Rate of raising and lowering","parameters":[{"name":"Zakres","range":"do 2 m/s"}],"parameters_en":[{"name":"Range","range":"do 2 m/s"}],"technique":"Metoda: pomiar pośredni","techniques":["Metoda: pomiar pośredni"],"technique_en":"Method: indirect measurement","computed":[],"computed_en":[],"activity":"Tempo podnoszenia i opuszczania\nZakres do 2 m/s\nMetoda: pomiar pośredni","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Tempo podnoszenia i opuszczania\nZakres do 2 m/s\nMetoda: pomiar pośredni PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Tempo podnoszenia i opuszczania\nZakres do 2 m/s\nMetoda: pomiar posredni PN-EN ISO 10535:2022-04","categories":["other"],"row_index":275,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Rate of raising and lowering Method: indirect measurement Range PN-EN ISO 10535:2022-04","parameters_zh":[{"name":"范围","range":"do 2 m/s"}],"search_zh":"医疗设备 － 残障人士转运升降装置 方法：间接测量 范围 PN-EN ISO 10535:2022-04","test_object_zh":"医疗设备 － 残障人士转运升降装置","technique_zh":"方法：间接测量"},{"_id":"6a5e78454cc76d93cba3b459","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Stabilność statyczna","methodology_en":"Static stability","parameters":[{"name":"Zakres","range":"(0 - 30)°"}],"parameters_en":[{"name":"Range","range":"(0 - 30)°"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Stabilność statyczna\nZakres (0 - 30)°\nMetoda: próba stateczności","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Stabilność statyczna\nZakres (0 - 30)°\nMetoda: próba stateczności PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Stabilnosc statyczna\nZakres (0 - 30)°\nMetoda: proba statecznosci PN-EN ISO 10535:2022-04","categories":["other"],"row_index":276,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Static stability Method: stability test Range PN-EN ISO 10535:2022-04","parameters_zh":[{"name":"范围","range":"(0 - 30)°"}],"search_zh":"医疗设备 － 残障人士转运升降装置 方法：稳定性试验 范围 PN-EN ISO 10535:2022-04","technique_zh":"方法：稳定性试验","test_object_zh":"医疗设备 － 残障人士转运升降装置"},{"_id":"6a5e78454cc76d93cba3b45a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Wytrzymałość mechaniczna urządzeń","methodology_en":"Mechanical strength of equipment","parameters":[],"parameters_en":[],"technique":"Metoda: spadek swobodny","techniques":["Metoda: spadek swobodny"],"technique_en":"Method: free fall","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna urządzeń\nMetoda: spadek swobodny","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Wytrzymałość mechaniczna urządzeń\nMetoda: spadek swobodny PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Wytrzymalosc mechaniczna urzadzen\nMetoda: spadek swobodny PN-EN ISO 10535:2022-04","categories":["other"],"row_index":277,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Mechanical strength of equipment Method: free fall PN-EN ISO 10535:2022-04","search_zh":"医疗设备 － 残障人士转运升降装置 设备的机械强度 PN-EN ISO 10535:2022-04","test_object_zh":"医疗设备 － 残障人士转运升降装置","methodology_zh":"设备的机械强度"},{"_id":"6a5e78454cc76d93cba3b45b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Wytrzymałość mechaniczna systemów podtrzymywania","methodology_en":"Mechanical strength of support systems","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Wytrzymałość mechaniczna systemów podtrzymywania\nMetoda: próba obciążenia PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Wytrzymalosc mechaniczna systemow podtrzymywania\nMetoda: proba obciazenia PN-EN ISO 10535:2022-04","categories":["other"],"row_index":278,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Mechanical strength of support systems Method: load test PN-EN ISO 10535:2022-04","search_zh":"医疗设备 － 残障人士转运升降装置 支撑系统的机械强度 方法：荷载试验 PN-EN ISO 10535:2022-04","technique_zh":"方法：荷载试验","test_object_zh":"医疗设备 － 残障人士转运升降装置","methodology_zh":"支撑系统的机械强度"},{"_id":"6a5e78454cc76d93cba3b45c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych","test_object_en":"Medical devices – Hoists for the transfer of disabled persons","methodology":"Siła umożliwiająca wprawienie w ruch urządzenia","methodology_en":"Force required to set the equipment in motion","parameters":[{"name":"Zakres","range":"(0,1 - 350) N"}],"parameters_en":[{"name":"Range","range":"(0,1 - 350) N"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 10535:2022-04","norm_bases":["PN-EN ISO 10535:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia medyczne – Podnośniki do przemieszczania osób niepełnosprawnych Siła umożliwiająca wprawienie w ruch urządzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezpośredni PN-EN ISO 10535:2022-04 Urzadzenia medyczne – Podnosniki do przemieszczania osob niepelnosprawnych Sila umozliwiajaca wprawienie w ruch urzadzenia\nZakres (0,1 - 350) N\nMetoda: pomiar bezposredni PN-EN ISO 10535:2022-04","categories":["other"],"row_index":279,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical devices – Hoists for the transfer of disabled persons Force required to set the equipment in motion Method: direct measurement Range PN-EN ISO 10535:2022-04","parameters_zh":[{"name":"范围","range":"(0,1 - 350) N"}],"search_zh":"医疗设备 － 残障人士转运升降装置 使设备启动所需的力 方法：直接测量 范围 PN-EN ISO 10535:2022-04","technique_zh":"方法：直接测量","test_object_zh":"医疗设备 － 残障人士转运升降装置","methodology_zh":"使设备启动所需的力"},{"_id":"6a5e78454cc76d93cba3b45d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Maszyny i urządzenia. Stopnie ochrony zapewniane przez obudowy (kod IP)","test_object_en":"Machinery and equipment. Degrees of protection provided by enclosures (IP code)","methodology":"Stopień ochrony IP","methodology_en":"IP degree of protection","parameters":[{"name":"Zakres","range":"IP 1X, 2X, 3X, 4X, X1, X2,"},{"name":"X3, X4, X5"}],"parameters_en":[{"name":"Range","range":"IP 1X, 2X, 3X, 4X, X1, X2,"},{"name":"X3, X4, X5"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stopień ochrony IP\nZakres:\nZakres IP 1X, 2X, 3X, 4X, X1, X2,\nX3, X4, X5","reference":"PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12P","norm_bases":["PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07","PN-EN 60529:2003/AC:2017-12P"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia. Stopnie ochrony zapewniane przez obudowy (kod IP) Stopień ochrony IP\nZakres:\nZakres IP 1X, 2X, 3X, 4X, X1, X2,\nX3, X4, X5 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12P Maszyny i urzadzenia. Stopnie ochrony zapewniane przez obudowy (kod IP) Stopien ochrony IP\nZakres:\nZakres IP 1X, 2X, 3X, 4X, X1, X2,\nX3, X4, X5 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12P","categories":["other"],"row_index":280,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Machinery and equipment. Degrees of protection provided by enclosures (IP code) IP degree of protection Range X3, X4, X5 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12P","parameters_zh":[{"name":"范围","range":"IP 1X, 2X, 3X, 4X, X1, X2,"},{"name":"X3, X4, X5"}],"search_zh":"机器与设备。外壳提供的防护等级（IP 代码） 范围 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | PN-EN 60529:2003/AC:2017-12P","test_object_zh":"机器与设备。外壳提供的防护等级（IP 代码）"},{"_id":"6a5e78454cc76d93cba3b45e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Wielkości liniowe","methodology_en":"Linear dimensions","parameters":[{"name":"Zakres","range":"(0 – 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wielkości liniowe\nZakres (0 – 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Wielkości liniowe\nZakres (0 – 5000) mm\nMetoda: pomiar bezpośredni PN-EN ISO 21856:2023-01 Produkty wspomagajace Wielkosci liniowe\nZakres (0 – 5000) mm\nMetoda: pomiar bezposredni PN-EN ISO 21856:2023-01","categories":["other"],"row_index":281,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Linear dimensions Method: direct measurement Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 5000) mm"}],"search_zh":"辅助制品 方法：直接测量 范围 PN-EN ISO 21856:2023-01","technique_zh":"方法：直接测量","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b45f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Wielkości kątowe","methodology_en":"Angular quantities","parameters":[{"name":"Zakres","range":"(0 – 220)°"}],"parameters_en":[{"name":"Range","range":"(0 – 220)°"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wielkości kątowe\nZakres (0 – 220)°\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Wielkości kątowe\nZakres (0 – 220)°\nMetoda: pomiar bezpośredni PN-EN ISO 21856:2023-01 Produkty wspomagajace Wielkosci katowe\nZakres (0 – 220)°\nMetoda: pomiar bezposredni PN-EN ISO 21856:2023-01","categories":["other"],"row_index":282,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Angular quantities Method: direct measurement Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 220)°"}],"search_zh":"辅助制品 角度量 方法：直接测量 范围 PN-EN ISO 21856:2023-01","technique_zh":"方法：直接测量","test_object_zh":"辅助制品","methodology_zh":"角度量"},{"_id":"6a5e78454cc76d93cba3b460","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Siła","methodology_en":"Force","parameters":[{"name":"Zakres","range":"(0,1 – 750) N"}],"parameters_en":[{"name":"Range","range":"(0,1 – 750) N"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Siła\nZakres (0,1 – 750) N\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Siła\nZakres (0,1 – 750) N\nMetoda: pomiar bezpośredni PN-EN ISO 21856:2023-01 Produkty wspomagajace Sila\nZakres (0,1 – 750) N\nMetoda: pomiar bezposredni PN-EN ISO 21856:2023-01","categories":["other"],"row_index":283,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Force Method: direct measurement Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0,1 – 750) N"}],"search_zh":"辅助制品 力 方法：直接测量 范围 PN-EN ISO 21856:2023-01","technique_zh":"方法：直接测量","test_object_zh":"辅助制品","methodology_zh":"力"},{"_id":"6a5e78454cc76d93cba3b461","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Prąd upływu szczątkowy, prąd upływu uziomowy, prąd upływu dotykowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)","methodology_en":"Residual leakage current, earth leakage current, touch leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part)","parameters":[{"name":"Zakres","range":"(0 – 10) A"}],"parameters_en":[{"name":"Range","range":"(0 – 10) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prąd upływu szczątkowy, prąd upływu uziomowy, prąd upływu dotykowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 – 10) A\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Prąd upływu szczątkowy, prąd upływu uziomowy, prąd upływu dotykowy, prąd upływu pacjenta, prąd pomocniczy pacjenta, prąd upływu pacjenta (napięcie sieciowe na części aplikacyjnej)\nZakres (0 – 10) A\nMetoda: pomiar bezpośredni PN-EN ISO 21856:2023-01 Produkty wspomagajace Prad uplywu szczatkowy, prad uplywu uziomowy, prad uplywu dotykowy, prad uplywu pacjenta, prad pomocniczy pacjenta, prad uplywu pacjenta (napiecie sieciowe na czesci aplikacyjnej)\nZakres (0 – 10) A\nMetoda: pomiar bezposredni PN-EN ISO 21856:2023-01","categories":["other"],"row_index":284,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Residual leakage current, earth leakage current, touch leakage current, patient leakage current, patient auxiliary current, patient leakage current (mains voltage on the applied part) Method: direct measurement Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 10) A"}],"search_zh":"辅助制品 方法：直接测量 范围 PN-EN ISO 21856:2023-01","technique_zh":"方法：直接测量","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b462","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Temperatura powierzchni","methodology_en":"Surface temperature","parameters":[{"name":"Zakres","range":"(-20 - 100)°C"}],"parameters_en":[{"name":"Range","range":"(-20 - 100)°C"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Temperatura powierzchni\nZakres (-20 - 100)°C\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Temperatura powierzchni\nZakres (-20 - 100)°C\nMetoda: pomiar bezpośredni PN-EN ISO 21856:2023-01 Produkty wspomagajace Temperatura powierzchni\nZakres (-20 - 100)°C\nMetoda: pomiar bezposredni PN-EN ISO 21856:2023-01","categories":["other"],"row_index":285,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Surface temperature Method: direct measurement Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(-20 - 100)°C"}],"search_zh":"辅助制品 方法：直接测量 范围 PN-EN ISO 21856:2023-01","technique_zh":"方法：直接测量","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b463","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Zapobieganie pułapkom na części ciała ludzkiego, bezpieczeństwo ruchomych części","methodology_en":"Prevention of entrapment of parts of the human body, safety of moving parts","parameters":[{"name":"Zakres","range":"(0 – 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 5000) mm"}],"technique":"Metoda: pomiar wielkości geometrycznych i badania próbnikami","techniques":["Metoda: pomiar wielkości geometrycznych i badania próbnikami"],"technique_en":"Method: measurement of geometric quantities and testing with probes","computed":[],"computed_en":[],"activity":"Zapobieganie pułapkom na części ciała ludzkiego, bezpieczeństwo ruchomych części\nZakres (0 – 5000) mm\nMetoda: pomiar wielkości geometrycznych i badania próbnikami","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Zapobieganie pułapkom na części ciała ludzkiego, bezpieczeństwo ruchomych części\nZakres (0 – 5000) mm\nMetoda: pomiar wielkości geometrycznych i badania próbnikami PN-EN ISO 21856:2023-01 Produkty wspomagajace Zapobieganie pulapkom na czesci ciala ludzkiego, bezpieczenstwo ruchomych czesci\nZakres (0 – 5000) mm\nMetoda: pomiar wielkosci geometrycznych i badania probnikami PN-EN ISO 21856:2023-01","categories":["other"],"row_index":286,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Prevention of entrapment of parts of the human body, safety of moving parts Method: measurement of geometric quantities and testing with probes Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 5000) mm"}],"search_zh":"辅助制品 范围 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b464","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Wytrzymałość mechaniczna urządzeń","methodology_en":"Mechanical strength of equipment","parameters":[],"parameters_en":[],"technique":"Metoda: Próba upadku, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie o framugę drzwi","techniques":["Metoda: Próba upadku, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie o framugę drzwi"],"technique_en":"Method: Drop test, impact against a protruding 40 mm threshold, descent from a 40 mm step, impact against a door frame","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna urządzeń\nMetoda: Próba upadku, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie o framugę drzwi","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Wytrzymałość mechaniczna urządzeń\nMetoda: Próba upadku, uderzenie w wystający próg 40 mm, zjazd z uskoku 40 mm, uderzenie o framugę drzwi PN-EN ISO 21856:2023-01 Produkty wspomagajace Wytrzymalosc mechaniczna urzadzen\nMetoda: Proba upadku, uderzenie w wystajacy prog 40 mm, zjazd z uskoku 40 mm, uderzenie o framuge drzwi PN-EN ISO 21856:2023-01","categories":["other"],"row_index":287,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Mechanical strength of equipment Method: Drop test, impact against a protruding 40 mm threshold, descent from a 40 mm step, impact against a door frame PN-EN ISO 21856:2023-01","search_zh":"辅助制品 设备的机械强度 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品","methodology_zh":"设备的机械强度"},{"_id":"6a5e78454cc76d93cba3b465","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Wytrzymałość uchwytów","methodology_en":"Strength of handles","parameters":[{"name":"Zakres","range":"(0 – 18) kN"}],"parameters_en":[{"name":"Range","range":"(0 – 18) kN"}],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość uchwytów\nZakres (0 – 18) kN\nMetoda: próba obciążenia","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Wytrzymałość uchwytów\nZakres (0 – 18) kN\nMetoda: próba obciążenia PN-EN ISO 21856:2023-01 Produkty wspomagajace Wytrzymalosc uchwytow\nZakres (0 – 18) kN\nMetoda: proba obciazenia PN-EN ISO 21856:2023-01","categories":["other"],"row_index":288,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Strength of handles Method: load test Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 18) kN"}],"search_zh":"辅助制品 方法：荷载试验 范围 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品","technique_zh":"方法：荷载试验"},{"_id":"6a5e78454cc76d93cba3b466","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Stabilność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 – 30)°"}],"parameters_en":[{"name":"Range","range":"(0 – 30)°"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Stabilność\nZakres (0 – 30)°\nMetoda: próba stateczności","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Stabilność\nZakres (0 – 30)°\nMetoda: próba stateczności PN-EN ISO 21856:2023-01 Produkty wspomagajace Stabilnosc\nZakres (0 – 30)°\nMetoda: proba statecznosci PN-EN ISO 21856:2023-01","categories":["other"],"row_index":289,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Stability Method: stability test Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 30)°"}],"search_zh":"辅助制品 稳定性 方法：稳定性试验 范围 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品","technique_zh":"方法：稳定性试验","methodology_zh":"稳定性"},{"_id":"6a5e78454cc76d93cba3b467","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Wytrzymałość statyczna","methodology_en":"Static strength","parameters":[{"name":"Zakres","range":"(0 – 18) kN"}],"parameters_en":[{"name":"Range","range":"(0 – 18) kN"}],"technique":"Metoda: próba nacisku","techniques":["Metoda: próba nacisku"],"technique_en":"Method: compression test","computed":[],"computed_en":[],"activity":"Wytrzymałość statyczna\nZakres (0 – 18) kN\nMetoda: próba nacisku","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Wytrzymałość statyczna\nZakres (0 – 18) kN\nMetoda: próba nacisku PN-EN ISO 21856:2023-01 Produkty wspomagajace Wytrzymalosc statyczna\nZakres (0 – 18) kN\nMetoda: proba nacisku PN-EN ISO 21856:2023-01","categories":["other"],"row_index":290,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Static strength Method: compression test Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 18) kN"}],"search_zh":"辅助制品 静强度 方法：加压试验 范围 PN-EN ISO 21856:2023-01","methodology_zh":"静强度","test_object_zh":"辅助制品","technique_zh":"方法：加压试验"},{"_id":"6a5e78454cc76d93cba3b468","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Wytrzymałość mechaniczna","methodology_en":"Mechanical strength","parameters":[{"name":"Zakres","range":"(0 – 18) kN"}],"parameters_en":[{"name":"Range","range":"(0 – 18) kN"}],"technique":"Metoda: próba nacisku","techniques":["Metoda: próba nacisku"],"technique_en":"Method: compression test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna\nZakres (0 – 18) kN\nMetoda: próba nacisku","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Wytrzymałość mechaniczna\nZakres (0 – 18) kN\nMetoda: próba nacisku PN-EN ISO 21856:2023-01 Produkty wspomagajace Wytrzymalosc mechaniczna\nZakres (0 – 18) kN\nMetoda: proba nacisku PN-EN ISO 21856:2023-01","categories":["other"],"row_index":291,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Mechanical strength Method: compression test Range PN-EN ISO 21856:2023-01","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"(0 – 18) kN"}],"search_zh":"辅助制品 机械强度 方法：加压试验 范围 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品","technique_zh":"方法：加压试验"},{"_id":"6a5e78454cc76d93cba3b469","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Ukształtowanie elementów konstrukcyjnych","methodology_en":"Shaping of structural elements","parameters":[{"name":"Zakres","range":"(0 – 5000) mm oraz"},{"name":"Zakres","range":"(0 – 220)°"}],"parameters_en":[{"name":"Range","range":"(0 – 5000) mm oraz"},{"name":"Range","range":"(0 – 220)°"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Ukształtowanie elementów konstrukcyjnych\nZakres:\nZakres (0 – 5000) mm oraz\nZakres (0 – 220)°\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Ukształtowanie elementów konstrukcyjnych\nZakres:\nZakres (0 – 5000) mm oraz\nZakres (0 – 220)°\nMetoda: pomiar bezpośredni PN-EN ISO 21856:2023-01 Produkty wspomagajace Uksztaltowanie elementow konstrukcyjnych\nZakres:\nZakres (0 – 5000) mm oraz\nZakres (0 – 220)°\nMetoda: pomiar bezposredni PN-EN ISO 21856:2023-01","categories":["other"],"row_index":292,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Shaping of structural elements Method: direct measurement Range Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 5000) mm oraz"},{"name":"范围","range":"(0 – 220)°"}],"search_zh":"辅助制品 方法：直接测量 范围 范围 PN-EN ISO 21856:2023-01","technique_zh":"方法：直接测量","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b46a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Zasady ergonomiczne","methodology_en":"Ergonomic principles","parameters":[{"name":"Zakres","range":"(0 – 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 5000) mm"}],"technique":"Metoda: pomiar wielkości geometrycznych","techniques":["Metoda: pomiar wielkości geometrycznych"],"technique_en":"Method: measurement of geometric quantities","computed":[],"computed_en":[],"activity":"Zasady ergonomiczne\nZakres (0 – 5000) mm\nMetoda: pomiar wielkości geometrycznych","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Zasady ergonomiczne\nZakres (0 – 5000) mm\nMetoda: pomiar wielkości geometrycznych PN-EN ISO 21856:2023-01 Produkty wspomagajace Zasady ergonomiczne\nZakres (0 – 5000) mm\nMetoda: pomiar wielkosci geometrycznych PN-EN ISO 21856:2023-01","categories":["other"],"row_index":293,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Ergonomic principles Method: measurement of geometric quantities Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 5000) mm"}],"search_zh":"辅助制品 范围 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b46b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Bezpieczeństwo użytkowania przez dzieci","methodology_en":"Safety in use by children","parameters":[],"parameters_en":[],"technique":"Metoda: ocena zgodności rozmiaru elementu z cylindrem","techniques":["Metoda: ocena zgodności rozmiaru elementu z cylindrem"],"technique_en":"Method: assessment of the conformity of the part size with the cylinder","computed":[],"computed_en":[],"activity":"Bezpieczeństwo użytkowania przez dzieci\nMetoda: ocena zgodności rozmiaru elementu z cylindrem","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Bezpieczeństwo użytkowania przez dzieci\nMetoda: ocena zgodności rozmiaru elementu z cylindrem PN-EN ISO 21856:2023-01 Produkty wspomagajace Bezpieczenstwo uzytkowania przez dzieci\nMetoda: ocena zgodnosci rozmiaru elementu z cylindrem PN-EN ISO 21856:2023-01","categories":["other"],"row_index":294,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Safety in use by children Method: assessment of the conformity of the part size with the cylinder PN-EN ISO 21856:2023-01","search_zh":"辅助制品 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b46c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Bezpieczeństwo użytkowania","methodology_en":"Safety in use","parameters":[{"name":"Zakres","range":"(0 – 20) kg oraz (0 – 1000) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 20) kg oraz (0 – 1000) mm"}],"technique":"Metoda: próba upadku","techniques":["Metoda: próba upadku"],"technique_en":"Method: drop test","computed":[],"computed_en":[],"activity":"Bezpieczeństwo użytkowania\nZakres (0 – 20) kg oraz (0 – 1000) mm\nMetoda: próba upadku","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Bezpieczeństwo użytkowania\nZakres (0 – 20) kg oraz (0 – 1000) mm\nMetoda: próba upadku PN-EN ISO 21856:2023-01 Produkty wspomagajace Bezpieczenstwo uzytkowania\nZakres (0 – 20) kg oraz (0 – 1000) mm\nMetoda: proba upadku PN-EN ISO 21856:2023-01","categories":["other"],"row_index":295,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Safety in use Method: drop test Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 20) kg oraz (0 – 1000) mm"}],"search_zh":"辅助制品 使用安全性 范围 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品","methodology_zh":"使用安全性"},{"_id":"6a5e78454cc76d93cba3b46d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Odporność urządzenia na przelanie cieczy, odporność na rozlanie cieczy, odporność na przedostanie się cieczy","methodology_en":"Resistance of the device to liquid overflow, resistance to liquid spillage, resistance to liquid ingress","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność urządzenia na przelanie cieczy, odporność na rozlanie cieczy, odporność na przedostanie się cieczy","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Odporność urządzenia na przelanie cieczy, odporność na rozlanie cieczy, odporność na przedostanie się cieczy PN-EN ISO 21856:2023-01 Produkty wspomagajace Odpornosc urzadzenia na przelanie cieczy, odpornosc na rozlanie cieczy, odpornosc na przedostanie sie cieczy PN-EN ISO 21856:2023-01","categories":["other"],"row_index":296,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Resistance of the device to liquid overflow, resistance to liquid spillage, resistance to liquid ingress PN-EN ISO 21856:2023-01","search_zh":"辅助制品 PN-EN ISO 21856:2023-01","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b46e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Produkty wspomagające","test_object_en":"Auxiliary products","methodology":"Wytrzymałość i trwałość","methodology_en":"Strength and durability","parameters":[{"name":"Zakres","range":"(0 – 18) kN"}],"parameters_en":[{"name":"Range","range":"(0 – 18) kN"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i trwałość\nZakres (0 – 18) kN","reference":"PN-EN ISO 21856:2023-01","norm_bases":["PN-EN ISO 21856:2023-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Produkty wspomagające Wytrzymałość i trwałość\nZakres (0 – 18) kN PN-EN ISO 21856:2023-01 Produkty wspomagajace Wytrzymalosc i trwalosc\nZakres (0 – 18) kN PN-EN ISO 21856:2023-01","categories":["other"],"row_index":297,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Auxiliary products Strength and durability Range PN-EN ISO 21856:2023-01","parameters_zh":[{"name":"范围","range":"(0 – 18) kN"}],"search_zh":"辅助制品 强度与耐久性 范围 PN-EN ISO 21856:2023-01","methodology_zh":"强度与耐久性","test_object_zh":"辅助制品"},{"_id":"6a5e78454cc76d93cba3b46f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Oporność elektryczna","methodology_en":"Electrical resistance","parameters":[{"name":"Zakres","range":"(0 – 45) MΩ"}],"parameters_en":[{"name":"Range","range":"(0 – 45) MΩ"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Oporność elektryczna\nZakres (0 – 45) MΩ\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Oporność elektryczna\nZakres (0 – 45) MΩ\nMetoda: pomiar bezpośredni PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Opornosc elektryczna\nZakres (0 – 45) MΩ\nMetoda: pomiar bezposredni PN-EN ISO 11197:2020-04","categories":["other"],"row_index":298,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Electrical resistance Method: direct measurement Range PN-EN ISO 11197:2020-04","parameters_zh":[{"name":"范围","range":"(0 – 45) MΩ"}],"search_zh":"医疗供应单位 方法：直接测量 范围 PN-EN ISO 11197:2020-04","technique_zh":"方法：直接测量","test_object_zh":"医疗供应单位"},{"_id":"6a5e78454cc76d93cba3b470","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Odporność na uderzenia","methodology_en":"Impact resistance","parameters":[],"parameters_en":[],"technique":"Metoda: próba uderzeniowa","techniques":["Metoda: próba uderzeniowa"],"technique_en":"Method: impact test","computed":[],"computed_en":[],"activity":"Odporność na uderzenia\nMetoda: próba uderzeniowa","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Odporność na uderzenia\nMetoda: próba uderzeniowa PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Odpornosc na uderzenia\nMetoda: proba uderzeniowa PN-EN ISO 11197:2020-04","categories":["other"],"row_index":299,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Impact resistance Method: impact test PN-EN ISO 11197:2020-04","search_zh":"医疗供应单位 耐冲击性 PN-EN ISO 11197:2020-04","test_object_zh":"医疗供应单位","methodology_zh":"耐冲击性"},{"_id":"6a5e78454cc76d93cba3b471","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Wytrzymałość statyczna","methodology_en":"Static strength","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość statyczna\nMetoda: próba obciążenia","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Wytrzymałość statyczna\nMetoda: próba obciążenia PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Wytrzymalosc statyczna\nMetoda: proba obciazenia PN-EN ISO 11197:2020-04","categories":["other"],"row_index":300,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Static strength Method: load test PN-EN ISO 11197:2020-04","methodology_zh":"静强度","search_zh":"医疗供应单位 静强度 方法：荷载试验 PN-EN ISO 11197:2020-04","technique_zh":"方法：荷载试验","test_object_zh":"医疗供应单位"},{"_id":"6a5e78454cc76d93cba3b472","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Zagrożenia mechaniczne związane z elementami nośnymi","methodology_en":"Mechanical hazards related to load-bearing components","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia i stabilności","techniques":["Metoda: próba obciążenia i stabilności"],"technique_en":"Method: load and stability test","computed":[],"computed_en":[],"activity":"Zagrożenia mechaniczne związane z elementami nośnymi\nMetoda: próba obciążenia i stabilności","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Zagrożenia mechaniczne związane z elementami nośnymi\nMetoda: próba obciążenia i stabilności PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Zagrozenia mechaniczne zwiazane z elementami nosnymi\nMetoda: proba obciazenia i stabilnosci PN-EN ISO 11197:2020-04","categories":["other"],"row_index":301,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Mechanical hazards related to load-bearing components Method: load and stability test PN-EN ISO 11197:2020-04","search_zh":"医疗供应单位 PN-EN ISO 11197:2020-04","test_object_zh":"医疗供应单位"},{"_id":"6a5e78454cc76d93cba3b473","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(-20 - 100)°C"}],"parameters_en":[{"name":"Range","range":"(-20 - 100)°C"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (-20 - 100)°C\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Temperatura wydzielana przez różne części urządzenia\nZakres (-20 - 100)°C\nMetoda: pomiar bezpośredni PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (-20 - 100)°C\nMetoda: pomiar bezposredni PN-EN ISO 11197:2020-04","categories":["other"],"row_index":302,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Temperature emitted by various parts of the appliance Method: direct measurement Range PN-EN ISO 11197:2020-04","parameters_zh":[{"name":"范围","range":"(-20 - 100)°C"}],"search_zh":"医疗供应单位 设备各部件散发的温度 方法：直接测量 范围 PN-EN ISO 11197:2020-04","technique_zh":"方法：直接测量","methodology_zh":"设备各部件散发的温度","test_object_zh":"医疗供应单位"},{"_id":"6a5e78454cc76d93cba3b474","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Przekrój poprzeczny okablowania","methodology_en":"Cross-section of the wiring","parameters":[{"name":"Zakres","range":"(0 – 50) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 50) mm"}],"technique":"Metoda: pomiar bezpośredni oraz pomiar pośredni","techniques":["Metoda: pomiar bezpośredni oraz pomiar pośredni"],"technique_en":"Method: direct measurement and indirect measurement","computed":[],"computed_en":[],"activity":"Przekrój poprzeczny okablowania\nZakres (0 – 50) mm\nMetoda: pomiar bezpośredni oraz pomiar pośredni","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Przekrój poprzeczny okablowania\nZakres (0 – 50) mm\nMetoda: pomiar bezpośredni oraz pomiar pośredni PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Przekroj poprzeczny okablowania\nZakres (0 – 50) mm\nMetoda: pomiar bezposredni oraz pomiar posredni PN-EN ISO 11197:2020-04","categories":["other"],"row_index":303,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Cross-section of the wiring Method: direct measurement and indirect measurement Range PN-EN ISO 11197:2020-04","parameters_zh":[{"name":"范围","range":"(0 – 50) mm"}],"search_zh":"医疗供应单位 范围 PN-EN ISO 11197:2020-04","test_object_zh":"医疗供应单位"},{"_id":"6a5e78454cc76d93cba3b475","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Odpowietrzenie","methodology_en":"Air release","parameters":[],"parameters_en":[],"technique":"Metoda: próba szczelności","techniques":["Metoda: próba szczelności"],"technique_en":"Method: leak tightness test","computed":[],"computed_en":[],"activity":"Odpowietrzenie\nMetoda: próba szczelności","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Odpowietrzenie\nMetoda: próba szczelności PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Odpowietrzenie\nMetoda: proba szczelnosci PN-EN ISO 11197:2020-04","categories":["other"],"row_index":304,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Air release Method: leak tightness test PN-EN ISO 11197:2020-04","search_zh":"医疗供应单位 PN-EN ISO 11197:2020-04","test_object_zh":"医疗供应单位"},{"_id":"6a5e78454cc76d93cba3b476","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Jednostki zaopatrzenia medycznego","test_object_en":"Medical supply units","methodology":"Wielkości liniowe","methodology_en":"Linear dimensions","parameters":[{"name":"Zakres","range":"(0 – 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wielkości liniowe\nZakres (0 – 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN ISO 11197:2020-04","norm_bases":["PN-EN ISO 11197:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Jednostki zaopatrzenia medycznego Wielkości liniowe\nZakres (0 – 5000) mm\nMetoda: pomiar bezpośredni PN-EN ISO 11197:2020-04 Jednostki zaopatrzenia medycznego Wielkosci liniowe\nZakres (0 – 5000) mm\nMetoda: pomiar bezposredni PN-EN ISO 11197:2020-04","categories":["other"],"row_index":305,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical supply units Linear dimensions Method: direct measurement Range PN-EN ISO 11197:2020-04","parameters_zh":[{"name":"范围","range":"(0 – 5000) mm"}],"search_zh":"医疗供应单位 方法：直接测量 范围 PN-EN ISO 11197:2020-04","technique_zh":"方法：直接测量","test_object_zh":"医疗供应单位"},{"_id":"6a5e78454cc76d93cba3b477","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Systemy rurociągowe do gazów medycznych","test_object_en":"Medical gas pipeline systems","methodology":"Sygnały wizualne – czytelność oznakowania","methodology_en":"Visual signals – legibility of markings","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Sygnały wizualne – czytelność oznakowania","reference":"PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03","norm_bases":["PN-EN ISO 7396-1:2016-07","PN-EN ISO 7396-1:2016-07/A1:2019-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy rurociągowe do gazów medycznych Sygnały wizualne – czytelność oznakowania PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03 Systemy rurociagowe do gazow medycznych Sygnaly wizualne – czytelnosc oznakowania PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03","categories":["other"],"row_index":306,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical gas pipeline systems Visual signals – legibility of markings PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03"},{"_id":"6a5e78454cc76d93cba3b478","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Systemy rurociągowe do gazów medycznych","test_object_en":"Medical gas pipeline systems","methodology":"Szczelność i wytrzymałość mechaniczna","methodology_en":"Tightness and mechanical strength","parameters":[],"parameters_en":[],"technique":"Metoda: próba ciśnieniowa","techniques":["Metoda: próba ciśnieniowa"],"technique_en":"Method: pressure test","computed":[],"computed_en":[],"activity":"Szczelność i wytrzymałość mechaniczna\nMetoda: próba ciśnieniowa","reference":"PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03","norm_bases":["PN-EN ISO 7396-1:2016-07","PN-EN ISO 7396-1:2016-07/A1:2019-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy rurociągowe do gazów medycznych Szczelność i wytrzymałość mechaniczna\nMetoda: próba ciśnieniowa PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03 Systemy rurociagowe do gazow medycznych Szczelnosc i wytrzymalosc mechaniczna\nMetoda: proba cisnieniowa PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03","categories":["other"],"row_index":307,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical gas pipeline systems Tightness and mechanical strength Method: pressure test PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03"},{"_id":"6a5e78454cc76d93cba3b479","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Systemy rurociągowe do gazów medycznych","test_object_en":"Medical gas pipeline systems","methodology":"Obecność połączeń krzyżowych","methodology_en":"Presence of cross-links","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność połączeń krzyżowych","reference":"PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03","norm_bases":["PN-EN ISO 7396-1:2016-07","PN-EN ISO 7396-1:2016-07/A1:2019-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Systemy rurociągowe do gazów medycznych Obecność połączeń krzyżowych PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03 Systemy rurociagowe do gazow medycznych Obecnosc polaczen krzyzowych PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03","categories":["other"],"row_index":308,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Medical gas pipeline systems Presence of cross-links PN-EN ISO 7396-1:2016-07 | PN-EN ISO 7396-1:2016-07/A1:2019-03"},{"_id":"6a5e78454cc76d93cba3b47a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Punkty poboru dla systemów","test_object_en":"Punkty poboru dla systemów","methodology":"Szczelność i wydajność","methodology_en":"Tightness and efficiency","parameters":[{"name":"Zakres","range":"(-90 – 1 200) kPa"}],"parameters_en":[{"name":"Range","range":"(-90 – 1 200) kPa"}],"technique":"Metoda: próba ciśnieniowa","techniques":["Metoda: próba ciśnieniowa"],"technique_en":"Method: pressure test","computed":[],"computed_en":[],"activity":"Szczelność i wydajność\nZakres (-90 – 1 200) kPa\nMetoda: próba ciśnieniowa","reference":"PN-EN ISO 9170-1:2020-12","norm_bases":["PN-EN ISO 9170-1:2020-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Punkty poboru dla systemów Szczelność i wydajność\nZakres (-90 – 1 200) kPa\nMetoda: próba ciśnieniowa PN-EN ISO 9170-1:2020-12 Punkty poboru dla systemow Szczelnosc i wydajnosc\nZakres (-90 – 1 200) kPa\nMetoda: proba cisnieniowa PN-EN ISO 9170-1:2020-12","categories":["other"],"row_index":309,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Punkty poboru dla systemów Tightness and efficiency Method: pressure test Range PN-EN ISO 9170-1:2020-12","parameters_zh":[{"name":"范围","range":"(-90 – 1 200) kPa"}],"search_zh":"范围 PN-EN ISO 9170-1:2020-12"},{"_id":"6a5e78454cc76d93cba3b47b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Napięcie","methodology_en":"Voltage","parameters":[{"name":"Zakres","range":"(0,001 – 900) V"}],"parameters_en":[{"name":"Range","range":"(0,001 – 900) V"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Napięcie\nZakres (0,001 – 900) V\nMetoda: pomiar bezpośredni","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Napięcie\nZakres (0,001 – 900) V\nMetoda: pomiar bezpośredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Napiecie\nZakres (0,001 – 900) V\nMetoda: pomiar bezposredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":310,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Voltage Method: direct measurement Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0,001 – 900) V"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 电压 方法：直接测量 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","technique_zh":"方法：直接测量","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"电压"},{"_id":"6a5e78454cc76d93cba3b47c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Prąd","methodology_en":"Current","parameters":[{"name":"Zakres","range":"(0,001 – 30) A"}],"parameters_en":[{"name":"Range","range":"(0,001 – 30) A"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Prąd\nZakres (0,001 – 30) A\nMetoda: pomiar bezpośredni","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Prąd\nZakres (0,001 – 30) A\nMetoda: pomiar bezpośredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Prad\nZakres (0,001 – 30) A\nMetoda: pomiar bezposredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":311,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Current Method: direct measurement Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0,001 – 30) A"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 电流 方法：直接测量 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","technique_zh":"方法：直接测量","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"电流"},{"_id":"6a5e78454cc76d93cba3b47d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Moc","methodology_en":"Power","parameters":[{"name":"Zakres","range":"(0,001 – 9000,0) W"},{"name":"Zakres","range":"(0,001 – 9000,0) VA"}],"parameters_en":[{"name":"Range","range":"(0,001 – 9000,0) W"},{"name":"Range","range":"(0,001 – 9000,0) VA"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Moc\nZakres:\nZakres (0,001 – 9000,0) W\nZakres (0,001 – 9000,0) VA\nMetoda: pomiar bezpośredni","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Moc\nZakres:\nZakres (0,001 – 9000,0) W\nZakres (0,001 – 9000,0) VA\nMetoda: pomiar bezpośredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Moc\nZakres:\nZakres (0,001 – 9000,0) W\nZakres (0,001 – 9000,0) VA\nMetoda: pomiar bezposredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":312,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Power Method: direct measurement Range Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0,001 – 9000,0) W"},{"name":"范围","range":"(0,001 – 9000,0) VA"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 功率 方法：直接测量 范围 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","technique_zh":"方法：直接测量","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"功率"},{"_id":"6a5e78454cc76d93cba3b47e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Częstotliwość","methodology_en":"Frequency","parameters":[{"name":"Zakres","range":"(0,00 – 300000) Hz"}],"parameters_en":[{"name":"Range","range":"(0,00 – 300000) Hz"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Częstotliwość\nZakres (0,00 – 300000) Hz","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Częstotliwość\nZakres (0,00 – 300000) Hz PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Czestotliwosc\nZakres (0,00 – 300000) Hz PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":313,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Frequency Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0,00 – 300000) Hz"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 频率 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","methodology_zh":"频率","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b47f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Temperatura wydzielana przez różne części urządzenia","methodology_en":"Temperature emitted by various parts of the appliance","parameters":[{"name":"Zakres","range":"(-20 - 100)°C"}],"parameters_en":[{"name":"Range","range":"(-20 - 100)°C"}],"technique":"Metoda: pomiar temperatury","techniques":["Metoda: pomiar temperatury"],"technique_en":"Method: temperature measurement","computed":[],"computed_en":[],"activity":"Temperatura wydzielana przez różne części urządzenia\nZakres (-20 - 100)°C\nMetoda: pomiar temperatury","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Temperatura wydzielana przez różne części urządzenia\nZakres (-20 - 100)°C\nMetoda: pomiar temperatury PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Temperatura wydzielana przez rozne czesci urzadzenia\nZakres (-20 - 100)°C\nMetoda: pomiar temperatury PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":314,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Temperature emitted by various parts of the appliance Method: temperature measurement Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(-20 - 100)°C"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 设备各部件散发的温度 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"设备各部件散发的温度"},{"_id":"6a5e78454cc76d93cba3b480","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Temperatura uzwojeń","methodology_en":"Winding temperature","parameters":[],"parameters_en":[],"technique":"Metoda: rezystancyjna","techniques":["Metoda: rezystancyjna"],"technique_en":"Method: resistive","computed":[],"computed_en":[],"activity":"Temperatura uzwojeń\nMetoda: rezystancyjna","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Temperatura uzwojeń\nMetoda: rezystancyjna PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Temperatura uzwojen\nMetoda: rezystancyjna PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":315,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Winding temperature Method: resistive PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b481","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Rozprzestrzenianie się ognia","methodology_en":"Fire spread","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Rozprzestrzenianie się ognia","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Rozprzestrzenianie się ognia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Rozprzestrzenianie sie ognia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":316,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Fire spread PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b482","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Trwałość oznakowania","methodology_en":"Durability of marking","parameters":[],"parameters_en":[],"technique":"Metoda: próba trwałości oznakowania (określony środek, alkohol)","techniques":["Metoda: próba trwałości oznakowania (określony środek, alkohol)"],"technique_en":"Method: durability test of the marking (specified agent, alcohol)","computed":[],"computed_en":[],"activity":"Trwałość oznakowania\nMetoda: próba trwałości oznakowania (określony środek, alkohol)","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Trwałość oznakowania\nMetoda: próba trwałości oznakowania (określony środek, alkohol) PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Trwalosc oznakowania\nMetoda: proba trwalosci oznakowania (okreslony srodek, alkohol) PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":317,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Durability of marking Method: durability test of the marking (specified agent, alcohol) PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 标识耐久性 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"标识耐久性"},{"_id":"6a5e78454cc76d93cba3b483","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Energia resztkowa","methodology_en":"Residual energy","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar napięcia","techniques":["Metoda: pomiar napięcia"],"technique_en":"Method: voltage measurement","computed":[],"computed_en":[],"activity":"Energia resztkowa\nMetoda: pomiar napięcia","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Energia resztkowa\nMetoda: pomiar napięcia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Energia resztkowa\nMetoda: pomiar napiecia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":318,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Residual energy Method: voltage measurement PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b484","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Dostępność","methodology_en":"Accessibility","parameters":[],"parameters_en":[],"technique":"Metoda: badania próbnikami – badanie palcami i pinami probierczymi","techniques":["Metoda: badania próbnikami – badanie palcami i pinami probierczymi"],"technique_en":"Method: testing with probes – testing with test fingers and test pins","computed":[],"computed_en":[],"activity":"Dostępność\nMetoda: badania próbnikami – badanie palcami i pinami probierczymi","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Dostępność\nMetoda: badania próbnikami – badanie palcami i pinami probierczymi PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Dostepnosc\nMetoda: badania probnikami – badanie palcami i pinami probierczymi PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":319,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Accessibility Method: testing with probes – testing with test fingers and test pins PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b485","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Napięcie / prąd / pojemność / zmagazynowana energia na częściach dostępnych","methodology_en":"Voltage / current / capacitance / stored energy on accessible parts","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar napięcia / prądu / ładunku pojemnościowego","techniques":["Metoda: pomiar napięcia / prądu / ładunku pojemnościowego"],"technique_en":"Method: measurement of voltage / current / capacitive charge","computed":[],"computed_en":[],"activity":"Napięcie / prąd / pojemność / zmagazynowana energia na częściach dostępnych\nMetoda: pomiar napięcia / prądu / ładunku pojemnościowego","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Napięcie / prąd / pojemność / zmagazynowana energia na częściach dostępnych\nMetoda: pomiar napięcia / prądu / ładunku pojemnościowego PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Napiecie / prad / pojemnosc / zmagazynowana energia na czesciach dostepnych\nMetoda: pomiar napiecia / pradu / ladunku pojemnosciowego PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":320,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Voltage / current / capacitance / stored energy on accessible parts Method: measurement of voltage / current / capacitive charge PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b486","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Test impedancji połączenia / ciągłości uziemienia","methodology_en":"Bonding impedance / earth continuity test","parameters":[{"name":"Zakres","range":"moment skręcający (0,0 –"},{"name":"11,5) Nm"}],"parameters_en":[{"name":"Range","range":"moment skręcający (0,0 –"},{"name":"11,5) Nm"}],"technique":"Metoda: próba dokręcenia i poluzowania","techniques":["Metoda: próba dokręcenia i poluzowania"],"technique_en":"Method: tightening and loosening test","computed":[],"computed_en":[],"activity":"Test impedancji połączenia / ciągłości uziemienia\nZakres:\nZakres moment skręcający (0,0 –\n11,5) Nm\nMetoda: próba dokręcenia i poluzowania","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Test impedancji połączenia / ciągłości uziemienia\nZakres:\nZakres moment skręcający (0,0 –\n11,5) Nm\nMetoda: próba dokręcenia i poluzowania PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Test impedancji polaczenia / ciaglosci uziemienia\nZakres:\nZakres moment skrecajacy (0,0 –\n11,5) Nm\nMetoda: proba dokrecenia i poluzowania PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":321,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Bonding impedance / earth continuity test Method: tightening and loosening test Range 11,5) Nm PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"moment skręcający (0,0 –"},{"name":"11,5) Nm"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b487","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Test impedancji połączenia / ciągłości uziemienia prądem min. 25 A","methodology_en":"Bonding impedance / earth continuity test with a current of min. 25 A","parameters":[{"name":"Zakres","range":"(0,001 – 2,100) Ω"}],"parameters_en":[{"name":"Range","range":"(0,001 – 2,100) Ω"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Test impedancji połączenia / ciągłości uziemienia prądem min. 25 A\nZakres (0,001 – 2,100) Ω\nMetoda: pomiar bezpośredni","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Test impedancji połączenia / ciągłości uziemienia prądem min. 25 A\nZakres (0,001 – 2,100) Ω\nMetoda: pomiar bezpośredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Test impedancji polaczenia / ciaglosci uziemienia pradem min. 25 A\nZakres (0,001 – 2,100) Ω\nMetoda: pomiar bezposredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":322,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Bonding impedance / earth continuity test with a current of min. 25 A Method: direct measurement Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0,001 – 2,100) Ω"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 方法：直接测量 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","technique_zh":"方法：直接测量","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b488","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Test rozładowania pojemnościowego","methodology_en":"Capacitive discharge test","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar napięcia","techniques":["Metoda: pomiar napięcia"],"technique_en":"Method: voltage measurement","computed":[],"computed_en":[],"activity":"Test rozładowania pojemnościowego\nMetoda: pomiar napięcia","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Test rozładowania pojemnościowego\nMetoda: pomiar napięcia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Test rozladowania pojemnosciowego\nMetoda: pomiar napiecia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":323,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Capacitive discharge test Method: voltage measurement PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b489","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Odstępy izolacyjne powierzchniowe i powietrzne","methodology_en":"Creepage distances and clearances","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Odstępy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezpośredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Odstepy izolacyjne powierzchniowe i powietrzne\nMetoda: pomiar bezposredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["construction"],"row_index":324,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Creepage distances and clearances Method: direct measurement PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 爬电距离与电气间隙 方法：直接测量 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","technique_zh":"方法：直接测量","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"爬电距离与电气间隙"},{"_id":"6a5e78454cc76d93cba3b48a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Wymiary geometryczne","methodology_en":"Geometric dimensions","parameters":[{"name":"Zakres","range":"(0 – 5000) mm"}],"parameters_en":[{"name":"Range","range":"(0 – 5000) mm"}],"technique":"Metoda: pomiar bezpośredni","techniques":["Metoda: pomiar bezpośredni"],"technique_en":"Method: direct measurement","computed":[],"computed_en":[],"activity":"Wymiary geometryczne\nZakres (0 – 5000) mm\nMetoda: pomiar bezpośredni","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Wymiary geometryczne\nZakres (0 – 5000) mm\nMetoda: pomiar bezpośredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Wymiary geometryczne\nZakres (0 – 5000) mm\nMetoda: pomiar bezposredni PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":325,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Geometric dimensions Method: direct measurement Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0 – 5000) mm"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 几何尺寸 方法：直接测量 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","methodology_zh":"几何尺寸","technique_zh":"方法：直接测量","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b48b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Wytrzymałość elektryczna izolacji","methodology_en":"Dielectric strength of the insulation","parameters":[{"name":"Zakres","range":"(0,5 – 4,0) kV"}],"parameters_en":[{"name":"Range","range":"(0,5 – 4,0) kV"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji\nZakres (0,5 – 4,0) kV","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Wytrzymałość elektryczna izolacji\nZakres (0,5 – 4,0) kV PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Wytrzymalosc elektryczna izolacji\nZakres (0,5 – 4,0) kV PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["construction"],"row_index":326,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Dielectric strength of the insulation Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0,5 – 4,0) kV"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 绝缘介电强度 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"绝缘介电强度"},{"_id":"6a5e78454cc76d93cba3b48c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Montaż nieodłącznych przewodów zasilających (wejście i odciążka przewodu)","methodology_en":"Installation of non-detachable supply cords (cord entry and cord anchorage)","parameters":[{"name":"wymiar geometryczny","range":"(0 – 300) mm,"},{"name":"siła","range":"(0,000 – 500) N,"},{"name":"moment skręcający","range":"(0,001 – 0,35)"},{"name":"Nm"}],"parameters_en":[{"name":"geometric dimension","range":"(0 – 300) mm,"},{"name":"force","range":"(0,000 – 500) N,"},{"name":"torsional moment","range":"(0,001 – 0,35)"},{"name":"Nm"}],"technique":"Metoda: pomiar wymiarów, próba ciągnięcia i próba skręcania","techniques":["Metoda: pomiar wymiarów, próba ciągnięcia i próba skręcania"],"technique_en":"Method: dimensional measurement, pull test and torsion test","computed":[],"computed_en":[],"activity":"Montaż nieodłącznych przewodów zasilających (wejście i odciążka przewodu)\nZakres:\nwymiar geometryczny (0 – 300) mm,\nsiła (0,000 – 500) N,\nmoment skręcający (0,001 – 0,35)\nNm\nMetoda: pomiar wymiarów, próba ciągnięcia i próba skręcania","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Montaż nieodłącznych przewodów zasilających (wejście i odciążka przewodu)\nZakres:\nwymiar geometryczny (0 – 300) mm,\nsiła (0,000 – 500) N,\nmoment skręcający (0,001 – 0,35)\nNm\nMetoda: pomiar wymiarów, próba ciągnięcia i próba skręcania PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Montaz nieodlacznych przewodow zasilajacych (wejscie i odciazka przewodu)\nZakres:\nwymiar geometryczny (0 – 300) mm,\nsila (0,000 – 500) N,\nmoment skrecajacy (0,001 – 0,35)\nNm\nMetoda: pomiar wymiarow, proba ciagniecia i proba skrecania PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":327,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Installation of non-detachable supply cords (cord entry and cord anchorage) Method: dimensional measurement, pull test and torsion test geometric dimension force torsional moment Nm PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"wymiar geometryczny","range":"(0 – 300) mm,"},{"name":"力","range":"(0,000 – 500) N,"},{"name":"moment skręcający","range":"(0,001 – 0,35)"},{"name":"Nm"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 力 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b48d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Ograniczenie siły i nacisku","methodology_en":"Force and pressure limitation","parameters":[{"name":"Zakres","range":"(0,000 – 500) N"}],"parameters_en":[{"name":"Range","range":"(0,000 – 500) N"}],"technique":"Metoda: pomiar siły i powierzchni kontaktu","techniques":["Metoda: pomiar siły i powierzchni kontaktu"],"technique_en":"Method: measurement of force and contact area","computed":[],"computed_en":[],"activity":"Ograniczenie siły i nacisku\nZakres (0,000 – 500) N\nMetoda: pomiar siły i powierzchni kontaktu","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Ograniczenie siły i nacisku\nZakres (0,000 – 500) N\nMetoda: pomiar siły i powierzchni kontaktu PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Ograniczenie sily i nacisku\nZakres (0,000 – 500) N\nMetoda: pomiar sily i powierzchni kontaktu PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":328,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Force and pressure limitation Method: measurement of force and contact area Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0,000 – 500) N"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b48e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Stabilność","methodology_en":"Stability","parameters":[{"name":"Zakres","range":"(0 – 30)°, siła (0,1 – 800) N"}],"parameters_en":[{"name":"Range","range":"(0 – 30)°, siła (0,1 – 800) N"}],"technique":"Metoda: próba stateczności","techniques":["Metoda: próba stateczności"],"technique_en":"Method: stability test","computed":[],"computed_en":[],"activity":"Stabilność\nZakres (0 – 30)°, siła (0,1 – 800) N\nMetoda: próba stateczności","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Stabilność\nZakres (0 – 30)°, siła (0,1 – 800) N\nMetoda: próba stateczności PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Stabilnosc\nZakres (0 – 30)°, sila (0,1 – 800) N\nMetoda: proba statecznosci PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":329,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Stability Method: stability test Range PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","parameters_zh":[{"name":"范围","range":"(0 – 30)°, siła (0,1 – 800) N"}],"search_zh":"电气测量仪器、自动化装置与实验室设备 稳定性 方法：稳定性试验 范围 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","technique_zh":"方法：稳定性试验","methodology_zh":"稳定性"},{"_id":"6a5e78454cc76d93cba3b48f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń","methodology_en":"Mechanical strength of handles and other means for carrying equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Wytrzymałość mechaniczna uchwytów i innych środków do przenoszenia urządzeń\nMetoda: próba obciążenia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Wytrzymalosc mechaniczna uchwytow i innych srodkow do przenoszenia urzadzen\nMetoda: proba obciazenia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":330,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Mechanical strength of handles and other means for carrying equipment Method: load test PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 把手及其他搬运设备用件的机械强度 方法：荷载试验 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","technique_zh":"方法：荷载试验","methodology_zh":"把手及其他搬运设备用件的机械强度"},{"_id":"6a5e78454cc76d93cba3b490","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Wytrzymałość mechaniczna systemów podtrzymywania i montaż naścienny","methodology_en":"Mechanical strength of support systems and wall mounting","parameters":[],"parameters_en":[],"technique":"Metoda: próba obciążenia","techniques":["Metoda: próba obciążenia"],"technique_en":"Method: load test","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna systemów podtrzymywania i montaż naścienny\nMetoda: próba obciążenia","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Wytrzymałość mechaniczna systemów podtrzymywania i montaż naścienny\nMetoda: próba obciążenia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Wytrzymalosc mechaniczna systemow podtrzymywania i montaz nascienny\nMetoda: proba obciazenia PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":331,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Mechanical strength of support systems and wall mounting Method: load test PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 方法：荷载试验 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","technique_zh":"方法：荷载试验"},{"_id":"6a5e78454cc76d93cba3b491","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Wytrzymałość mechaniczna urządzeń","methodology_en":"Mechanical strength of equipment","parameters":[],"parameters_en":[],"technique":"Metoda: próba statyczna, próba udaru, spadek swobodny","techniques":["Metoda: próba statyczna, próba udaru, spadek swobodny"],"technique_en":"Method: static test, impact test, free fall","computed":[],"computed_en":[],"activity":"Wytrzymałość mechaniczna urządzeń\nMetoda: próba statyczna, próba udaru, spadek swobodny","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Wytrzymałość mechaniczna urządzeń\nMetoda: próba statyczna, próba udaru, spadek swobodny PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Wytrzymalosc mechaniczna urzadzen\nMetoda: proba statyczna, proba udaru, spadek swobodny PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":332,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Mechanical strength of equipment Method: static test, impact test, free fall PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 设备的机械强度 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"设备的机械强度"},{"_id":"6a5e78454cc76d93cba3b492","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Obwód o ograniczonej energii","methodology_en":"Limited-energy circuit","parameters":[],"parameters_en":[],"technique":"Metoda: pomiar napięcia i natężenia prądu","techniques":["Metoda: pomiar napięcia i natężenia prądu"],"technique_en":"Method: measurement of voltage and current","computed":[],"computed_en":[],"activity":"Obwód o ograniczonej energii\nMetoda: pomiar napięcia i natężenia prądu","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Obwód o ograniczonej energii\nMetoda: pomiar napięcia i natężenia prądu PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Obwod o ograniczonej energii\nMetoda: pomiar napiecia i natezenia pradu PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":333,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Limited-energy circuit Method: measurement of voltage and current PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b493","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Odporność na ciepło","methodology_en":"Resistance to heat","parameters":[],"parameters_en":[],"technique":"Metoda: kondycjonowanie termiczne","techniques":["Metoda: kondycjonowanie termiczne"],"technique_en":"Method: thermal conditioning","computed":[],"computed_en":[],"activity":"Odporność na ciepło\nMetoda: kondycjonowanie termiczne","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Odporność na ciepło\nMetoda: kondycjonowanie termiczne PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Odpornosc na cieplo\nMetoda: kondycjonowanie termiczne PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":334,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Resistance to heat Method: thermal conditioning PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b494","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Odkształcenie obudowy przy próbie odporności na ciepło","methodology_en":"Deformation of the enclosure in the heat resistance test","parameters":[],"parameters_en":[],"technique":"Metoda: próba wciskania kulki","techniques":["Metoda: próba wciskania kulki"],"technique_en":"Method: ball pressure test","computed":[],"computed_en":[],"activity":"Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: próba wciskania kulki","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Odkształcenie obudowy przy próbie odporności na ciepło\nMetoda: próba wciskania kulki PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Odksztalcenie obudowy przy probie odpornosci na cieplo\nMetoda: proba wciskania kulki PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":335,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Deformation of the enclosure in the heat resistance test Method: ball pressure test PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 耐热试验时外壳的变形 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备","methodology_zh":"耐热试验时外壳的变形"},{"_id":"6a5e78454cc76d93cba3b495","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Ochrona przed zagrożeniami ze strony płynów","methodology_en":"Protection against hazards from fluids","parameters":[],"parameters_en":[],"technique":"Metoda: czyszczenie / odkażanie, oblanie, przelanie","techniques":["Metoda: czyszczenie / odkażanie, oblanie, przelanie"],"technique_en":"Method: cleaning / disinfection, pouring over, pouring through","computed":[],"computed_en":[],"activity":"Ochrona przed zagrożeniami ze strony płynów\nMetoda: czyszczenie / odkażanie, oblanie, przelanie","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Ochrona przed zagrożeniami ze strony płynów\nMetoda: czyszczenie / odkażanie, oblanie, przelanie PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Ochrona przed zagrozeniami ze strony plynow\nMetoda: czyszczenie / odkazanie, oblanie, przelanie PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":336,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Protection against hazards from fluids Method: cleaning / disinfection, pouring over, pouring through PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b496","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne","test_object_en":"Electrical measuring instruments, control equipment and laboratory devices","methodology":"Urządzenia zabezpieczające przed przegrzaniem","methodology_en":"Devices for protection against overheating","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Urządzenia zabezpieczające przed przegrzaniem","reference":"PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","norm_bases":["PN-EN 61010-1:2011","PN-EN 61010-1:2011/A1:2019-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Elektrycznych przyrządy pomiarowych, automatyka i urządzenia laboratoryjne Urządzenia zabezpieczające przed przegrzaniem PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04 Elektrycznych przyrzady pomiarowych, automatyka i urzadzenia laboratoryjne Urzadzenia zabezpieczajace przed przegrzaniem PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","categories":["other"],"row_index":337,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Electrical measuring instruments, control equipment and laboratory devices Devices for protection against overheating PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","search_zh":"电气测量仪器、自动化装置与实验室设备 PN-EN 61010-1:2011 | PN-EN 61010-1:2011/A1:2019-04","test_object_zh":"电气测量仪器、自动化装置与实验室设备"},{"_id":"6a5e78454cc76d93cba3b497","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Urządzenia techniczne, konstrukcje stalowe, materiały hutnicze, połączenia spawane E","test_object_en":"Technical equipment, steel structures, steel materials, welded joints E","methodology":"Twardość HV","methodology_en":"HV hardness","parameters":[],"parameters_en":[],"technique":"Metoda: dynamiczna UCI","techniques":["Metoda: dynamiczna UCI"],"technique_en":"Method: dynamic UCI","computed":[],"computed_en":[],"activity":"Twardość HV\nMetoda: dynamiczna UCI","reference":"MS-0045009","norm_bases":["MS-0045009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia techniczne, konstrukcje stalowe, materiały hutnicze, połączenia spawane E Twardość HV\nMetoda: dynamiczna UCI MS-0045009 Urzadzenia techniczne, konstrukcje stalowe, materialy hutnicze, polaczenia spawane E Twardosc HV\nMetoda: dynamiczna UCI MS-0045009","categories":["materials"],"row_index":338,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Technical equipment, steel structures, steel materials, welded joints E HV hardness Method: dynamic UCI MS-0045009","methodology_zh":"维氏硬度 HV","search_zh":"维氏硬度 HV MS-0045009"},{"_id":"6a5e78454cc76d93cba3b498","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Odlewy staliwne E","test_object_en":"Cast steel castings E","methodology":"Nieciągłości","methodology_en":"Discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: ultradźwiękowa","techniques":["Metoda: ultradźwiękowa"],"technique_en":"Method: ultrasonic","computed":[],"computed_en":[],"activity":"Nieciągłości\nMetoda: ultradźwiękowa","reference":"PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 12680-1 | PN-EN 12680-2","norm_bases":["PN-EN ISO 16810","PN-EN ISO 16811","PN-EN ISO 16827","PN-EN 12680-1","PN-EN 12680-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odlewy staliwne E Nieciągłości\nMetoda: ultradźwiękowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 12680-1 | PN-EN 12680-2 Odlewy staliwne E Nieciaglosci\nMetoda: ultradzwiekowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 12680-1 | PN-EN 12680-2","categories":["other"],"row_index":339,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Cast steel castings E Discontinuities Method: ultrasonic PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 12680-1 | PN-EN 12680-2","methodology_zh":"不连续性","search_zh":"不连续性 方法：超声法 PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 12680-1 | PN-EN 12680-2","technique_zh":"方法：超声法"},{"_id":"6a5e78454cc76d93cba3b499","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Odkuwki E","test_object_en":"Forgings E","methodology":"Nieciągłości","methodology_en":"Discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: ultradźwiękowa","techniques":["Metoda: ultradźwiękowa"],"technique_en":"Method: ultrasonic","computed":[],"computed_en":[],"activity":"Nieciągłości\nMetoda: ultradźwiękowa","reference":"PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10228-3 | PN-EN 10228-4","norm_bases":["PN-EN ISO 16810","PN-EN ISO 16811","PN-EN ISO 16827","PN-EN 10228-3","PN-EN 10228-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odkuwki E Nieciągłości\nMetoda: ultradźwiękowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10228-3 | PN-EN 10228-4 Odkuwki E Nieciaglosci\nMetoda: ultradzwiekowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10228-3 | PN-EN 10228-4","categories":["other"],"row_index":340,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Forgings E Discontinuities Method: ultrasonic PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10228-3 | PN-EN 10228-4","methodology_zh":"不连续性","search_zh":"不连续性 方法：超声法 PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10228-3 | PN-EN 10228-4","technique_zh":"方法：超声法"},{"_id":"6a5e78454cc76d93cba3b49a","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych E","test_object_en":"Welded joints in metallic materials E","methodology":"Nieciągłości","methodology_en":"Discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: ultradźwiękowa","techniques":["Metoda: ultradźwiękowa"],"technique_en":"Method: ultrasonic","computed":[],"computed_en":[],"activity":"Nieciągłości\nMetoda: ultradźwiękowa","reference":"PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN-EN ISO 16826 | PN-EN ISO 16827 | PN-EN ISO 17640 | PN-EN ISO 23279","norm_bases":["PN-EN ISO 16810","PN-EN ISO 16811","PN-EN ISO 16823","PN-EN ISO 16826","PN-EN ISO 16827","PN-EN ISO 17640","PN-EN ISO 23279"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza spawane materiałów metalowych E Nieciągłości\nMetoda: ultradźwiękowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN-EN ISO 16826 | PN-EN ISO 16827 | PN-EN ISO 17640 | PN-EN ISO 23279 Zlacza spawane materialow metalowych E Nieciaglosci\nMetoda: ultradzwiekowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN-EN ISO 16826 | PN-EN ISO 16827 | PN-EN ISO 17640 | PN-EN ISO 23279","categories":["materials"],"row_index":341,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Welded joints in metallic materials E Discontinuities Method: ultrasonic PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN-EN ISO 16826 | PN-EN ISO 16827 | PN-EN ISO 17640 | PN-EN ISO 23279","methodology_zh":"不连续性","search_zh":"不连续性 方法：超声法 PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN-EN ISO 16826 | PN-EN ISO 16827 | PN-EN ISO 17640 | PN-EN ISO 23279","technique_zh":"方法：超声法"},{"_id":"6a5e78454cc76d93cba3b49b","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyroby stalowe płaskie E","test_object_en":"Flat steel products E","methodology":"Nieciągłości","methodology_en":"Discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: ultradźwiękowa","techniques":["Metoda: ultradźwiękowa"],"technique_en":"Method: ultrasonic","computed":[],"computed_en":[],"activity":"Nieciągłości\nMetoda: ultradźwiękowa","reference":"PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10160","norm_bases":["PN-EN ISO 16810","PN-EN ISO 16811","PN-EN ISO 16827","PN-EN 10160"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby stalowe płaskie E Nieciągłości\nMetoda: ultradźwiękowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10160 Wyroby stalowe plaskie E Nieciaglosci\nMetoda: ultradzwiekowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10160","categories":["materials"],"row_index":342,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Flat steel products E Discontinuities Method: ultrasonic PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10160","methodology_zh":"不连续性","search_zh":"不连续性 方法：超声法 PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16827 | PN-EN 10160","technique_zh":"方法：超声法"},{"_id":"6a5e78454cc76d93cba3b49c","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyroby metalowe E","test_object_en":"Metal products E","methodology":"Grubość","methodology_en":"Thickness","parameters":[{"name":"Zakres","range":"(0,5-300 mm)"}],"parameters_en":[{"name":"Range","range":"(0,5-300 mm)"}],"technique":"Metoda: ultradźwiękowa","techniques":["Metoda: ultradźwiękowa"],"technique_en":"Method: ultrasonic","computed":[],"computed_en":[],"activity":"Grubość\nZakres (0,5-300 mm)\nMetoda: ultradźwiękowa","reference":"PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN EN ISO 16809","norm_bases":["PN-EN ISO 16810","PN-EN ISO 16811","PN-EN ISO 16823","PN EN ISO 16809"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby metalowe E Grubość\nZakres (0,5-300 mm)\nMetoda: ultradźwiękowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN EN ISO 16809 Wyroby metalowe E Grubosc\nZakres (0,5-300 mm)\nMetoda: ultradzwiekowa PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN EN ISO 16809","categories":["materials"],"row_index":343,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metal products E Thickness Method: ultrasonic Range PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN EN ISO 16809","parameters_zh":[{"name":"范围","range":"(0,5-300 mm)"}],"search_zh":"厚度 方法：超声法 范围 PN-EN ISO 16810 | PN-EN ISO 16811 | PN-EN ISO 16823 | PN EN ISO 16809","methodology_zh":"厚度","technique_zh":"方法：超声法"},{"_id":"6a5e78454cc76d93cba3b49d","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Odlewy z materiałów ferromagnetycznych E","test_object_en":"Castings of ferromagnetic materials E","methodology":"Nieciągłości powierzchniowe","methodology_en":"Surface discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: magnetyczno-proszkowa","techniques":["Metoda: magnetyczno-proszkowa"],"technique_en":"Method: magnetic particle","computed":[],"computed_en":[],"activity":"Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 1369","norm_bases":["PN-EN ISO 9934-1","PN-EN ISO 3059","PN-EN 1369"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odlewy z materiałów ferromagnetycznych E Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 1369 Odlewy z materialow ferromagnetycznych E Nieciaglosci powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 1369","categories":["materials"],"row_index":344,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Castings of ferromagnetic materials E Surface discontinuities Method: magnetic particle PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 1369","methodology_zh":"表面不连续性","search_zh":"表面不连续性 方法：磁粉法 PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 1369","technique_zh":"方法：磁粉法"},{"_id":"6a5e78454cc76d93cba3b49e","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Odkuwki z materiałów ferromagnetycznych E","test_object_en":"Forgings of ferromagnetic materials E","methodology":"Nieciągłości powierzchniowe","methodology_en":"Surface discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: magnetyczno-proszkowa","techniques":["Metoda: magnetyczno-proszkowa"],"technique_en":"Method: magnetic particle","computed":[],"computed_en":[],"activity":"Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 10228-1","norm_bases":["PN-EN ISO 9934-1","PN-EN ISO 3059","PN-EN 10228-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odkuwki z materiałów ferromagnetycznych E Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 10228-1 Odkuwki z materialow ferromagnetycznych E Nieciaglosci powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 10228-1","categories":["materials"],"row_index":345,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Forgings of ferromagnetic materials E Surface discontinuities Method: magnetic particle PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 10228-1","methodology_zh":"表面不连续性","search_zh":"表面不连续性 方法：磁粉法 PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN 10228-1","technique_zh":"方法：磁粉法"},{"_id":"6a5e78454cc76d93cba3b49f","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Rury z materiałów ferromagnetycznych E","test_object_en":"Pipes of ferromagnetic materials E","methodology":"Nieciągłości powierzchniowe","methodology_en":"Surface discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: magnetyczno-proszkowa","techniques":["Metoda: magnetyczno-proszkowa"],"technique_en":"Method: magnetic particle","computed":[],"computed_en":[],"activity":"Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 10893-5","norm_bases":["PN-EN ISO 9934-1","PN-EN ISO 3059","PN-EN ISO 10893-5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury z materiałów ferromagnetycznych E Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 10893-5 Rury z materialow ferromagnetycznych E Nieciaglosci powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 10893-5","categories":["materials"],"row_index":346,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Pipes of ferromagnetic materials E Surface discontinuities Method: magnetic particle PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 10893-5","methodology_zh":"表面不连续性","search_zh":"表面不连续性 方法：磁粉法 PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 10893-5","technique_zh":"方法：磁粉法"},{"_id":"6a5e78454cc76d93cba3b4a0","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Złącza spawane z materiałów ferromagnetycznych E","test_object_en":"Welded joints of ferromagnetic materials E","methodology":"Nieciągłości powierzchniowe","methodology_en":"Surface discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: magnetyczno-proszkowa","techniques":["Metoda: magnetyczno-proszkowa"],"technique_en":"Method: magnetic particle","computed":[],"computed_en":[],"activity":"Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa","reference":"PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 17638","norm_bases":["PN-EN ISO 9934-1","PN-EN ISO 3059","PN-EN ISO 17638"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza spawane z materiałów ferromagnetycznych E Nieciągłości powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 17638 Zlacza spawane z materialow ferromagnetycznych E Nieciaglosci powierzchniowe\nMetoda: magnetyczno-proszkowa PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 17638","categories":["materials"],"row_index":347,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Welded joints of ferromagnetic materials E Surface discontinuities Method: magnetic particle PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 17638","methodology_zh":"表面不连续性","search_zh":"表面不连续性 方法：磁粉法 PN-EN ISO 9934-1 | PN-EN ISO 3059 | PN-EN ISO 17638","technique_zh":"方法：磁粉法"},{"_id":"6a5e78454cc76d93cba3b4a1","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Odlewy E","test_object_en":"Castings E","methodology":"Nieciągłości otwarte na badaną powierzchnię","methodology_en":"Discontinuities open to the tested surface","parameters":[],"parameters_en":[],"technique":"Metoda: penetracyjna","techniques":["Metoda: penetracyjna"],"technique_en":"Method: penetrant","computed":[],"computed_en":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna","reference":"PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 1371-1 | PN-EN 1371-2","norm_bases":["PN-EN ISO 3452-1","PN-EN ISO 3059","PN-EN 1371-1","PN-EN 1371-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odlewy E Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 1371-1 | PN-EN 1371-2 Odlewy E Nieciaglosci otwarte na badana powierzchnie\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 1371-1 | PN-EN 1371-2","categories":["other"],"row_index":348,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Castings E Discontinuities open to the tested surface Method: penetrant PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 1371-1 | PN-EN 1371-2","methodology_zh":"向受检表面开口的不连续性","search_zh":"向受检表面开口的不连续性 方法：渗透法 PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 1371-1 | PN-EN 1371-2","technique_zh":"方法：渗透法"},{"_id":"6a5e78454cc76d93cba3b4a2","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Odkuwki stalowe E","test_object_en":"Steel forgings E","methodology":"Nieciągłości otwarte na badaną powierzchnię","methodology_en":"Discontinuities open to the tested surface","parameters":[],"parameters_en":[],"technique":"Metoda: penetracyjna","techniques":["Metoda: penetracyjna"],"technique_en":"Method: penetrant","computed":[],"computed_en":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna","reference":"PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 10228-2","norm_bases":["PN-EN ISO 3452-1","PN-EN ISO 3059","PN-EN 10228-2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odkuwki stalowe E Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 10228-2 Odkuwki stalowe E Nieciaglosci otwarte na badana powierzchnie\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 10228-2","categories":["materials"],"row_index":349,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel forgings E Discontinuities open to the tested surface Method: penetrant PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 10228-2","methodology_zh":"向受检表面开口的不连续性","search_zh":"向受检表面开口的不连续性 方法：渗透法 PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN 10228-2","technique_zh":"方法：渗透法"},{"_id":"6a5e78454cc76d93cba3b4a3","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Rury stalowe E","test_object_en":"Steel tubes E","methodology":"Nieciągłości otwarte na badaną powierzchnię","methodology_en":"Discontinuities open to the tested surface","parameters":[],"parameters_en":[],"technique":"Metoda: penetracyjna","techniques":["Metoda: penetracyjna"],"technique_en":"Method: penetrant","computed":[],"computed_en":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna","reference":"PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN ISO 10893-4","norm_bases":["PN-EN ISO 3452-1","PN-EN ISO 3059","PN-EN ISO 10893-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Rury stalowe E Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN ISO 10893-4 Rury stalowe E Nieciaglosci otwarte na badana powierzchnie\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN ISO 10893-4","categories":["materials"],"row_index":350,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Steel tubes E Discontinuities open to the tested surface Method: penetrant PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN ISO 10893-4","methodology_zh":"向受检表面开口的不连续性","search_zh":"向受检表面开口的不连续性 方法：渗透法 PN-EN ISO 3452-1 | PN-EN ISO 3059 | PN-EN ISO 10893-4","technique_zh":"方法：渗透法"},{"_id":"6a5e78454cc76d93cba3b4a4","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Złącza spawane E","test_object_en":"Welded joints E","methodology":"Nieciągłości otwarte na badaną powierzchnię","methodology_en":"Discontinuities open to the tested surface","parameters":[],"parameters_en":[],"technique":"Metoda: penetracyjna","techniques":["Metoda: penetracyjna"],"technique_en":"Method: penetrant","computed":[],"computed_en":[],"activity":"Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna","reference":"PN-EN ISO 3452-1 | PN-EN ISO 3059","norm_bases":["PN-EN ISO 3452-1","PN-EN ISO 3059"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza spawane E Nieciągłości otwarte na badaną powierzchnię\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059 Zlacza spawane E Nieciaglosci otwarte na badana powierzchnie\nMetoda: penetracyjna PN-EN ISO 3452-1 | PN-EN ISO 3059","categories":["other"],"row_index":351,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Welded joints E Discontinuities open to the tested surface Method: penetrant PN-EN ISO 3452-1 | PN-EN ISO 3059","methodology_zh":"向受检表面开口的不连续性","search_zh":"向受检表面开口的不连续性 方法：渗透法 PN-EN ISO 3452-1 | PN-EN ISO 3059","technique_zh":"方法：渗透法"},{"_id":"6a5e78454cc76d93cba3b4a5","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Wyroby z materiałów metalowych w tym: blachy, odlewy, odkuwki oraz rury E","test_object_en":"Products made of metallic materials including: sheets, castings, forgings and pipes E","methodology":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne","methodology_en":"Shape imperfections and external surface discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: wizualna","techniques":["Metoda: wizualna"],"technique_en":"Method: visual","computed":[],"computed_en":[],"activity":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda: wizualna","reference":"PN-EN 13018","norm_bases":["PN-EN 13018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby z materiałów metalowych w tym: blachy, odlewy, odkuwki oraz rury E Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda: wizualna PN-EN 13018 Wyroby z materialow metalowych w tym: blachy, odlewy, odkuwki oraz rury E Niedoskonalosci ksztaltu oraz nieciaglosci powierzchniowe zewnetrzne\nMetoda: wizualna PN-EN 13018","categories":["materials"],"row_index":352,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Products made of metallic materials including: sheets, castings, forgings and pipes E Shape imperfections and external surface discontinuities Method: visual PN-EN 13018","methodology_zh":"形状缺陷与外表面不连续性","search_zh":"形状缺陷与外表面不连续性 方法：目视法 PN-EN 13018","technique_zh":"方法：目视法"},{"_id":"6a5e78454cc76d93cba3b4a6","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych E","test_object_en":"Welded joints in metallic materials E","methodology":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne","methodology_en":"Shape imperfections and external surface discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: wizualna","techniques":["Metoda: wizualna"],"technique_en":"Method: visual","computed":[],"computed_en":[],"activity":"Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda: wizualna","reference":"PN-EN 13018 | PN-EN ISO 17637","norm_bases":["PN-EN 13018","PN-EN ISO 17637"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza spawane materiałów metalowych E Niedoskonałości kształtu oraz nieciągłości powierzchniowe zewnętrzne\nMetoda: wizualna PN-EN 13018 | PN-EN ISO 17637 Zlacza spawane materialow metalowych E Niedoskonalosci ksztaltu oraz nieciaglosci powierzchniowe zewnetrzne\nMetoda: wizualna PN-EN 13018 | PN-EN ISO 17637","categories":["materials"],"row_index":353,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Welded joints in metallic materials E Shape imperfections and external surface discontinuities Method: visual PN-EN 13018 | PN-EN ISO 17637","methodology_zh":"形状缺陷与外表面不连续性","search_zh":"形状缺陷与外表面不连续性 方法：目视法 PN-EN 13018 | PN-EN ISO 17637","technique_zh":"方法：目视法"},{"_id":"6a5e78454cc76d93cba3b4a7","lab_id":"69ad52a3de79e566650fb48a","country":"PL","accr_number":"AB 904","accr_body":"PCA","test_object":"Złącza spawane materiałów metalowych o grubości równoważnej dla stali do 40 mm E","test_object_en":"Welded joints of metallic materials with an equivalent thickness for steel up to 40 mm E","methodology":"Nieciągłości","methodology_en":"Discontinuities","parameters":[],"parameters_en":[],"technique":"Metoda: radiograficzna","techniques":["Metoda: radiograficzna"],"technique_en":"Method: radiographic","computed":[],"computed_en":[],"activity":"Nieciągłości\nMetoda: radiograficzna","reference":"PN-EN ISO 17636-1","norm_bases":["PN-EN ISO 17636-1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Złącza spawane materiałów metalowych o grubości równoważnej dla stali do 40 mm E Nieciągłości\nMetoda: radiograficzna PN-EN ISO 17636-1 Zlacza spawane materialow metalowych o grubosci rownowaznej dla stali do 40 mm E Nieciaglosci\nMetoda: radiograficzna PN-EN ISO 17636-1","categories":["materials"],"row_index":354,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Welded joints of metallic materials with an equivalent thickness for steel up to 40 mm E Discontinuities Method: radiographic PN-EN ISO 17636-1","methodology_zh":"不连续性","search_zh":"不连续性 方法：射线照相法 PN-EN ISO 17636-1","technique_zh":"方法：射线照相法"}],"has_pdf":true}