{"lab":{"_id":"69ad52a3de79e566650fb474","accr_number":"AB 885","country":"PL","accr_body":"PCA","address":"„EKOTERRA” Sp. z o. o., LABORATORIUM, ul. Zgoda 12, 25-378 Kielce","categories":["water","environment","materials"],"city":"Kielce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":64,"name":"PRZEDSIĘBIORSTWO NAUKOWO-TECHNICZNE","parse_status":"parsed","parse_version":3,"pdf_files":["AB_885.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo naukowo-techniczne „ekoterra” sp. z o. o., laboratorium, ul. zgoda 12, 25-378 kielce water other pharma electronics materials environment metrology","status":"active","updated_at":"2026-03-08T14:51:46.626Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:46.626Z","location":{"type":"Point","coordinates":[20.6286,50.8661]},"email_confidence":"high","email_mx":true,"email_source":"https://www.ekoterra.com.pl","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"C/31, C/36","pl":"Badania chemiczne gleby, gazów składowiskowych","en":"Chemical tests of soil, landfill gases"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/28/P, N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"N/31","pl":"Badania właściwości fizycznych gleby","en":"Tests of physical properties of soil"}],"issue":{"no":"20","date":"19.12.2025"},"parse_date":"2026-07-20T07:09:53.503Z","parse_source":"script-pdfplumber","map_coord":[50.862774,20.629194],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":57,"environment":5,"materials":4,"other":2},"category_scores":{"water":47.78,"environment":0.37,"materials":0.24,"other":0.06},"has_zh":true},"methods":[{"_id":"6a5dc9c1f1c10c8ce825f5b8","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 – 100) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Indeks nadmanganianowy\nZakres (1,0 – 100) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi, scieki Indeks nadmanganianowy\nZakres (1,0 – 100) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/dm3 O2"}],"search_zh":"水、生活饮用水、污水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5b9","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(10 – 7000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(10 – 7000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (10 – 7000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków\nZakres (10 – 7000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow\nZakres (10 – 7000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 – 7000) mg/dm3"}],"search_zh":"水、生活饮用水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5ba","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/dm3 CaCO3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/dm3 CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 2000) mg/dm3 CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 2000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi, scieki Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5,0 – 2000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/dm3 CaCO3"}],"search_zh":"水、生活饮用水、污水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5bb","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(10 – 5000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/dm3\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/dm3\nMetoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow\nZakres (10 – 5000) mg/dm3\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/dm3"}],"search_zh":"水、生活饮用水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5bc","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 90) mg/dm3"},{"name":"Zakres","range":"(0,44 – 400) mg/dm3 NO3-"}],"parameters_en":[{"name":"Range","range":"(0,10 – 90) mg/dm3"},{"name":"Range","range":"(0,44 – 400) mg/dm3 NO3-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 90) mg/dm3\nZakres (0,44 – 400) mg/dm3 NO3-\nMetoda spektrofotometryczna","reference":"PN-82/C-04576-08","norm_bases":["PN-82/C-04576-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 90) mg/dm3\nZakres (0,44 – 400) mg/dm3 NO3-\nMetoda spektrofotometryczna PN-82/C-04576-08 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,10 – 90) mg/dm3\nZakres (0,44 – 400) mg/dm3 NO3-\nMetoda spektrofotometryczna PN-82/C-04576-08","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Nitrate nitrogen concentration Spectrophotometric method Range Range PN-82/C-04576-08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 90) mg/dm3"},{"name":"范围","range":"(0,44 – 400) mg/dm3 NO3-"}],"search_zh":"水、生活饮用水、污水 硝态氮浓度 分光光度法 范围 范围 PN-82/C-04576-08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5bd","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,001 – 10,0) mg/dm3"},{"name":"Zakres","range":"(0,003 – 33,0) mg/dm3 NO2-"}],"parameters_en":[{"name":"Range","range":"(0,001 – 10,0) mg/dm3"},{"name":"Range","range":"(0,003 – 33,0) mg/dm3 NO2-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,001 – 10,0) mg/dm3\nZakres (0,003 – 33,0) mg/dm3 NO2-\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,001 – 10,0) mg/dm3\nZakres (0,003 – 33,0) mg/dm3 NO2-\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,001 – 10,0) mg/dm3\nZakres (0,003 – 33,0) mg/dm3 NO2-\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Nitrite nitrogen concentration Spectrophotometric method Range Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 10,0) mg/dm3"},{"name":"范围","range":"(0,003 – 33,0) mg/dm3 NO2-"}],"search_zh":"水、生活饮用水、污水 亚硝态氮浓度 分光光度法 范围 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5be","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 2,0) mg/dm3"},{"name":"Zakres","range":"(0,30 – 2,6) mg/dm3 NH4+"},{"name":"Zakres","range":"(0,24 – 2,4) mg/dm3 NH3"}],"parameters_en":[{"name":"Range","range":"(0,20 – 2,0) mg/dm3"},{"name":"Range","range":"(0,30 – 2,6) mg/dm3 NH4+"},{"name":"Range","range":"(0,24 – 2,4) mg/dm3 NH3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,20 – 2,0) mg/dm3\nZakres (0,30 – 2,6) mg/dm3 NH4+\nZakres (0,24 – 2,4) mg/dm3 NH3\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,20 – 2,0) mg/dm3\nZakres (0,30 – 2,6) mg/dm3 NH4+\nZakres (0,24 – 2,4) mg/dm3 NH3\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu amonowego\nZakres:\nZakres (0,20 – 2,0) mg/dm3\nZakres (0,30 – 2,6) mg/dm3 NH4+\nZakres (0,24 – 2,4) mg/dm3 NH3\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Ammonium nitrogen concentration Spectrophotometric method Range Range Range PN-C-04576-4:1994","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 2,0) mg/dm3"},{"name":"范围","range":"(0,30 – 2,6) mg/dm3 NH4+"},{"name":"范围","range":"(0,24 – 2,4) mg/dm3 NH3"}],"search_zh":"水、生活饮用水、污水 氨氮浓度 分光光度法 范围 范围 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5bf","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 10) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie żelaza ogólnego\nZakres (0,010 – 10) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda, woda do spozycia przez ludzi, scieki Stezenie zelaza ogolnego\nZakres (0,010 – 10) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 + Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/dm3"}],"search_zh":"水、生活饮用水、污水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5c0","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 20 000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 20 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 20 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (10 – 20 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 20 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 20 000) μS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5c1","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 70) mg/dm3 Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 70) mg/dm3 Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 70) mg/dm3 Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Barwa\nZakres (5 – 70) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7 Woda, woda do spozycia przez ludzi, scieki Barwa\nZakres (5 – 70) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Colour Visual method Range PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/dm3 Pt"}],"search_zh":"水、生活饮用水、污水 色度 目视法 范围 PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","technique_zh":"目视法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5c2","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5c3","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(0,050 – 3,00) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,050 – 3,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (0,050 – 3,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie glinu\nZakres (0,050 – 3,00) mg/dm3\nMetoda spektrofotometryczna PN-92/C-04605/02 Woda, woda do spozycia przez ludzi, scieki Stezenie glinu\nZakres (0,050 – 3,00) mg/dm3\nMetoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Aluminium concentration Spectrophotometric method Range PN-92/C-04605/02","parameters_zh":[{"name":"范围","range":"(0,050 – 3,00) mg/dm3"}],"search_zh":"水、生活饮用水、污水 铝浓度 分光光度法 范围 PN-92/C-04605/02","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"铝浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5c4","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,010 – 3) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,010 – 3) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,010 – 3) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-10, wydanie 1 z dnia 20.09.2006 r.","norm_bases":["PB-10, wydanie 1 z dnia 20.09.2006 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie manganu\nZakres (0,010 – 3) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10, wydanie 1 z dnia 20.09.2006 r. Woda, woda do spozycia przez ludzi, scieki Stezenie manganu\nZakres (0,010 – 3) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10, wydanie 1 z dnia 20.09.2006 r.","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PB-10, wydanie 1 z dnia 20.09.2006 r.","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 3) mg/dm3"}],"search_zh":"水、生活饮用水、污水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PB-10, wydanie 1 z dnia 20.09.2006 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5c5","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie miedzi","methodology_en":"Copper concentration","parameters":[{"name":"Zakres","range":"(0,010 – 3,00) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,010 – 3,00) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie miedzi\nZakres (0,010 – 3,00) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie miedzi\nZakres (0,010 – 3,00) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie miedzi\nZakres (0,010 – 3,00) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Copper concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002","parameters_zh":[{"name":"范围","range":"(0,010 – 3,00) mg/dm3"}],"search_zh":"水、生活饮用水、污水 铜浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"铜浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5c6","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie ogólnego węgla organicznego","methodology_en":"Total organic carbon concentration","parameters":[{"name":"Zakres","range":"(0,5 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 100) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (0,5 – 100) mg/dm3\nMetoda miareczkowa","reference":"PB-23, wydanie 1 z dnia 03.08.2007 r.","norm_bases":["PB-23, wydanie 1 z dnia 03.08.2007 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie ogólnego węgla organicznego\nZakres (0,5 – 100) mg/dm3\nMetoda miareczkowa PB-23, wydanie 1 z dnia 03.08.2007 r. Woda, woda do spozycia przez ludzi, scieki Stezenie ogolnego wegla organicznego\nZakres (0,5 – 100) mg/dm3\nMetoda miareczkowa PB-23, wydanie 1 z dnia 03.08.2007 r.","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater Total organic carbon concentration Titrimetric method Range PB-23, wydanie 1 z dnia 03.08.2007 r.","parameters_zh":[{"name":"范围","range":"(0,5 – 100) mg/dm3"}],"search_zh":"水、生活饮用水、污水 总有机碳浓度 滴定法 范围 PB-23, wydanie 1 z dnia 03.08.2007 r.","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"总有机碳浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5c7","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","methodology_en":"Chemical oxygen demand - COD","parameters":[{"name":"Zakres","range":"(10 – 7000) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(10 – 7000) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10 – 7000) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10 – 7000) mg/dm3 O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10 – 7000) mg/dm3 O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand - COD Titrimetric method Range PN-ISO 6060:2006","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(10 – 7000) mg/dm3 O2"}],"search_zh":"水、废水 化学需氧量 ChZT（COD） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5c8","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(10 – 2000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(10 – 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (10 – 2000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (10 – 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (10 – 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(10 – 2000) mg/dm3"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5c9","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Substancje rozpuszczone","methodology_en":"Dissolved solids","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(10 – 5000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje rozpuszczone\nZakres (10 – 5000) mg/dm3\nMetoda wagowa","reference":"PB-03, wydanie 1 z dnia 20.09.2006 r.","norm_bases":["PB-03, wydanie 1 z dnia 20.09.2006 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Substancje rozpuszczone\nZakres (10 – 5000) mg/dm3\nMetoda wagowa PB-03, wydanie 1 z dnia 20.09.2006 r. Woda, scieki Substancje rozpuszczone\nZakres (10 – 5000) mg/dm3\nMetoda wagowa PB-03, wydanie 1 z dnia 20.09.2006 r.","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved solids Gravimetric method Range PB-03, wydanie 1 z dnia 20.09.2006 r.","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/dm3"}],"search_zh":"水、废水 溶解性固体 重量法 范围 PB-03, wydanie 1 z dnia 20.09.2006 r.","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性固体"},{"_id":"6a5dc9c1f1c10c8ce825f5ca","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(10 – 6000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(10 – 6000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (10 – 6000) mg/dm3\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (10 – 6000) mg/dm3\nMetoda wagowa PN-78/C-04541 Woda, scieki Sucha pozostalosc\nZakres (10 – 6000) mg/dm3\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dry residue Gravimetric method Range PN-78/C-04541","parameters_zh":[{"name":"范围","range":"(10 – 6000) mg/dm3"}],"search_zh":"水、废水 干残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"干残渣"},{"_id":"6a5dc9c1f1c10c8ce825f5cb","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Substancje ekstrahujące się eterem naftowym","methodology_en":"Substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(5,0 – 30) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5,0 – 30) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (5,0 – 30) mg/dm3\nMetoda wagowa","reference":"PB-25, wydanie 1 z dnia 02.06.2008 r.","norm_bases":["PB-25, wydanie 1 z dnia 02.06.2008 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Substancje ekstrahujące się eterem naftowym\nZakres (5,0 – 30) mg/dm3\nMetoda wagowa PB-25, wydanie 1 z dnia 02.06.2008 r. Woda, scieki Substancje ekstrahujace sie eterem naftowym\nZakres (5,0 – 30) mg/dm3\nMetoda wagowa PB-25, wydanie 1 z dnia 02.06.2008 r.","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Substances extractable with petroleum ether Gravimetric method Range PB-25, wydanie 1 z dnia 02.06.2008 r.","parameters_zh":[{"name":"范围","range":"(5,0 – 30) mg/dm3"}],"search_zh":"水、废水 石油醚可萃取物 重量法 范围 PB-25, wydanie 1 z dnia 02.06.2008 r.","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取物"},{"_id":"6a5dc9c1f1c10c8ce825f5cc","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/dm3"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5cd","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,0 – 600) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,0 – 600) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 600) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (2,0 – 600) mg/dm3\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (2,0 – 600) mg/dm3\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 600) mg/dm3"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5ce","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5cf","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,005 – 5) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,005 – 5) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,005 – 5) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,005 – 5) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Indeks fenolowy\nZakres (0,005 – 5) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","parameters_zh":[{"name":"范围","range":"(0,005 – 5) mg/dm3"}],"search_zh":"水、废水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a5dc9c1f1c10c8ce825f5d0","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(0,50 – 500) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 500) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (0,50 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+ PN-ISO 9964-1/AK+Ap1:2009","norm_bases":["PN-ISO 9964-1:1994+ PN-ISO 9964-1/AK+Ap1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie sodu\nZakres (0,50 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+ PN-ISO 9964-1/AK+Ap1:2009 Woda, scieki Stezenie sodu\nZakres (0,50 – 500) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+ PN-ISO 9964-1/AK+Ap1:2009","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+ PN-ISO 9964-1/AK+Ap1:2009","parameters_zh":[{"name":"范围","range":"(0,50 – 500) mg/dm3"}],"search_zh":"水、废水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+ PN-ISO 9964-1/AK+Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","methodology_zh":"钠浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5d1","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie węglowodorów aromatycznych","methodology_en":"Concentration of aromatic hydrocarbons","parameters":[{"name":"Benzen","range":"(0,025 – 2,4) mg/dm3"},{"name":"Toluen","range":"(0,025 – 2,4) mg/dm3"},{"name":"Etylobenzen","range":"(0,025 – 2,4) mg/dm3"},{"name":"o-Ksylen","range":"(0,025 – 2,4) mg/dm3"},{"name":"m+p -Ksylen","range":"(0,050 – 4,8) mg/dm3"},{"name":"Kumen","range":"(0,025 – 2,4) mg/dm3"}],"parameters_en":[{"name":"Benzene","range":"(0,025 – 2,4) mg/dm3"},{"name":"Toluene","range":"(0,025 – 2,4) mg/dm3"},{"name":"Ethylbenzene","range":"(0,025 – 2,4) mg/dm3"},{"name":"o-Xylene","range":"(0,025 – 2,4) mg/dm3"},{"name":"m+p -Xylene","range":"(0,050 – 4,8) mg/dm3"},{"name":"Cumene","range":"(0,025 – 2,4) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie węglowodorów aromatycznych\nZakres:\nBenzen (0,025 – 2,4) mg/dm3\nToluen (0,025 – 2,4) mg/dm3\nEtylobenzen (0,025 – 2,4) mg/dm3\no-Ksylen (0,025 – 2,4) mg/dm3\nm+p -Ksylen (0,050 – 4,8) mg/dm3\nKumen (0,025 – 2,4) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-14, wydanie 2 z dnia 20.09.2015 r.","norm_bases":["PB-14, wydanie 2 z dnia 20.09.2015 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie węglowodorów aromatycznych\nZakres:\nBenzen (0,025 – 2,4) mg/dm3\nToluen (0,025 – 2,4) mg/dm3\nEtylobenzen (0,025 – 2,4) mg/dm3\no-Ksylen (0,025 – 2,4) mg/dm3\nm+p -Ksylen (0,050 – 4,8) mg/dm3\nKumen (0,025 – 2,4) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-14, wydanie 2 z dnia 20.09.2015 r. Woda, scieki Stezenie weglowodorow aromatycznych\nZakres:\nBenzen (0,025 – 2,4) mg/dm3\nToluen (0,025 – 2,4) mg/dm3\nEtylobenzen (0,025 – 2,4) mg/dm3\no-Ksylen (0,025 – 2,4) mg/dm3\nm+p -Ksylen (0,050 – 4,8) mg/dm3\nKumen (0,025 – 2,4) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-14, wydanie 2 z dnia 20.09.2015 r.","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of aromatic hydrocarbons Gas chromatography with flame ionization detection (GC-FID) Benzene Toluene Ethylbenzene o-Xylene m+p -Xylene Cumene PB-14, wydanie 2 z dnia 20.09.2015 r.","search_zh":"水、废水 芳香烃浓度 气相色谱-氢火焰离子化检测法（GC-FID） 苯 甲苯 乙苯 邻二甲苯 PB-14, wydanie 2 z dnia 20.09.2015 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","parameters_zh":[{"name":"苯","range":"(0,025 – 2,4) mg/dm3"},{"name":"甲苯","range":"(0,025 – 2,4) mg/dm3"},{"name":"乙苯","range":"(0,025 – 2,4) mg/dm3"},{"name":"邻二甲苯","range":"(0,025 – 2,4) mg/dm3"},{"name":"m+p -Ksylen","range":"(0,050 – 4,8) mg/dm3"},{"name":"Kumen","range":"(0,025 – 2,4) mg/dm3"}],"methodology_zh":"芳香烃浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5d2","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma BTEX (z obliczeń), Suma JWA (jednopierścieniowe węglowodory aromatyczne) (z obliczeń)","methodology_en":"Sum of BTEX (calculated), Sum of MAH (monocyclic aromatic hydrocarbons) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma BTEX (z obliczeń), Suma JWA (jednopierścieniowe węglowodory aromatyczne) (z obliczeń)","reference":"PB-14, wydanie 2 z dnia 20.09.2015 r.","norm_bases":["PB-14, wydanie 2 z dnia 20.09.2015 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma BTEX (z obliczeń), Suma JWA (jednopierścieniowe węglowodory aromatyczne) (z obliczeń) PB-14, wydanie 2 z dnia 20.09.2015 r. Woda, scieki Suma BTEX (z obliczen), Suma JWA (jednopierscieniowe weglowodory aromatyczne) (z obliczen) PB-14, wydanie 2 z dnia 20.09.2015 r.","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sum of BTEX (calculated), Sum of MAH (monocyclic aromatic hydrocarbons) (calculated) PB-14, wydanie 2 z dnia 20.09.2015 r.","search_zh":"水、废水 PB-14, wydanie 2 z dnia 20.09.2015 r.","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5d3","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie węglowodorów ropopochodnych (C12-C36)","methodology_en":"Concentration of petroleum hydrocarbons (C12-C36)","parameters":[{"name":"Zakres","range":"(1,30 – 26,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(1,30 – 26,0) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Stężenie węglowodorów ropopochodnych (C12-C36)\nZakres (1,30 – 26,0) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-24, wydanie 1 z dnia 20.11.2018 r.","norm_bases":["PB-24, wydanie 1 z dnia 20.11.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie węglowodorów ropopochodnych (C12-C36)\nZakres (1,30 – 26,0) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-24, wydanie 1 z dnia 20.11.2018 r. Woda, scieki Stezenie weglowodorow ropopochodnych (C12-C36)\nZakres (1,30 – 26,0) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-24, wydanie 1 z dnia 20.11.2018 r.","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of petroleum hydrocarbons (C12-C36) Gas chromatography with flame ionization detection (GC-FID) Range PB-24, wydanie 1 z dnia 20.11.2018 r.","parameters_zh":[{"name":"范围","range":"(1,30 – 26,0) mg/dm3"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-24, wydanie 1 z dnia 20.11.2018 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5d4","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma benzyn/węglowodory ropopochodne (C6-C12)","methodology_en":"Sum of gasolines/petroleum hydrocarbons (C6-C12)","parameters":[{"name":"Zakres","range":"(0,025 – 20) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,025 – 20) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Suma benzyn/węglowodory ropopochodne (C6-C12)\nZakres (0,025 – 20) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-20, wydanie 1 z dnia 03.08.2007 r.","norm_bases":["PB-20, wydanie 1 z dnia 03.08.2007 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma benzyn/węglowodory ropopochodne (C6-C12)\nZakres (0,025 – 20) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-20, wydanie 1 z dnia 03.08.2007 r. Woda, scieki Suma benzyn/weglowodory ropopochodne (C6-C12)\nZakres (0,025 – 20) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-20, wydanie 1 z dnia 03.08.2007 r.","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sum of gasolines/petroleum hydrocarbons (C6-C12) Gas chromatography with flame ionization detection (GC-FID) Range PB-20, wydanie 1 z dnia 03.08.2007 r.","parameters_zh":[{"name":"范围","range":"(0,025 – 20) mg/dm3"}],"search_zh":"水、废水 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PB-20, wydanie 1 z dnia 03.08.2007 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5d5","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chromu (VI)","methodology_en":"Chromium(VI) concentration","parameters":[{"name":"Zakres","range":"(0,002 – 0,2) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,002 – 0,2) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu (VI)\nZakres (0,002 – 0,2) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-17, wydanie1 z dnia 20.09.2006 r.","norm_bases":["PB-17, wydanie1 z dnia 20.09.2006 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chromu (VI)\nZakres (0,002 – 0,2) mg/dm3\nMetoda spektrofotometryczna PB-17, wydanie1 z dnia 20.09.2006 r. Woda, scieki Stezenie chromu (VI)\nZakres (0,002 – 0,2) mg/dm3\nMetoda spektrofotometryczna PB-17, wydanie1 z dnia 20.09.2006 r.","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chromium(VI) concentration Spectrophotometric method Range PB-17, wydanie1 z dnia 20.09.2006 r.","parameters_zh":[{"name":"范围","range":"(0,002 – 0,2) mg/dm3"}],"search_zh":"水、废水 六价铬浓度 分光光度法 范围 PB-17, wydanie1 z dnia 20.09.2006 r.","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5d6","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,005 – 20) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,005 – 20) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,005 – 20) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010, rozdział 8","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010, rozdział 8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,005 – 20) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010, rozdział 8 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,005 – 20) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010, rozdzial 8","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010, rozdział 8","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 20) mg/dm3"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010, rozdział 8","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5d7","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,015 – 60) mg/dm3 PO4"}],"parameters_en":[{"name":"Range","range":"(0,015 – 60) mg/dm3 PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,015 – 60) mg/dm3 PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt.4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,015 – 60) mg/dm3 PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt.4 Woda, scieki Stezenie ortofosforanow\nZakres (0,015 – 60) mg/dm3 PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt.4","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt.4","parameters_zh":[{"name":"范围","range":"(0,015 – 60) mg/dm3 PO4"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 pkt.4","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5d8","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 20) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(0,20 – 20) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,20 – 20) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,20 – 20) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,20 – 20) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(0,20 – 20) mg/dm3 O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5d9","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zasadowość","methodology_en":"Alkalinity","parameters":[{"name":"Zakres","range":"(1,0 – 12) mmol/dm3"}],"parameters_en":[{"name":"Range","range":"(1,0 – 12) mmol/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość\nZakres (1,0 – 12) mmol/dm3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 rozdział 8.2","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004 rozdział 8.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zasadowość\nZakres (1,0 – 12) mmol/dm3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 rozdział 8.2 Woda, scieki Zasadowosc\nZakres (1,0 – 12) mmol/dm3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 rozdzial 8.2","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004 rozdział 8.2","parameters_zh":[{"name":"范围","range":"(1,0 – 12) mmol/dm3"}],"search_zh":"水、废水 碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004 rozdział 8.2","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"碱度"},{"_id":"6a5dc9c1f1c10c8ce825f5da","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/dm3 O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c1f1c10c8ce825f5db","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","methodology_en":"Biochemical oxygen demand – BOD5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(3 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/dm3 O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9c1f1c10c8ce825f5dc","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chromu ogólnego","methodology_en":"Total chromium concentration","parameters":[{"name":"Zakres","range":"(0,010 – 20) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,010 – 20) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie chromu ogólnego\nZakres (0,010 – 20) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000","norm_bases":["PN-EN 1233:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chromu ogólnego\nZakres (0,010 – 20) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 Woda, scieki Stezenie chromu ogolnego\nZakres (0,010 – 20) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total chromium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN 1233:2000","parameters_zh":[{"name":"范围","range":"(0,010 – 20) mg/dm3"}],"search_zh":"水、废水 总铬浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN 1233:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","methodology_zh":"总铬浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5dd","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma chlorków i siarczanów (z obliczeń)","methodology_en":"Sum of chlorides and sulphates (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma chlorków i siarczanów (z obliczeń)","reference":"PB-30, wydanie 1 z dnia 02.06.2009 r.","norm_bases":["PB-30, wydanie 1 z dnia 02.06.2009 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma chlorków i siarczanów (z obliczeń) PB-30, wydanie 1 z dnia 02.06.2009 r. Woda, scieki Suma chlorkow i siarczanow (z obliczen) PB-30, wydanie 1 z dnia 02.06.2009 r.","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sum of chlorides and sulphates (calculated) PB-30, wydanie 1 z dnia 02.06.2009 r.","search_zh":"水、废水 氯化物与硫酸盐总量（由计算得出） PB-30, wydanie 1 z dnia 02.06.2009 r.","test_object_zh":"水、废水","methodology_zh":"氯化物与硫酸盐总量（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f5de","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie surfaktantów (detergentów anionowych)","methodology_en":"Concentration of surfactants (anionic detergents)","parameters":[{"name":"Zakres","range":"(0,100 – 20) mg/dm3 MBAS"}],"parameters_en":[{"name":"Range","range":"(0,100 – 20) mg/dm3 MBAS"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów (detergentów anionowych)\nZakres (0,100 – 20) mg/dm3 MBAS\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie surfaktantów (detergentów anionowych)\nZakres (0,100 – 20) mg/dm3 MBAS\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, scieki Stezenie surfaktantow (detergentow anionowych)\nZakres (0,100 – 20) mg/dm3 MBAS\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of surfactants (anionic detergents) Spectrophotometric method Range PN-EN 903:2002","parameters_zh":[{"name":"范围","range":"(0,100 – 20) mg/dm3 MBAS"}],"search_zh":"水、废水 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5df","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(0,010 – 3,00) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,010 – 3,00) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (0,010 – 3,00) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-29, wydanie 1 z dnia 03.08.2007 r.","norm_bases":["PB-29, wydanie 1 z dnia 03.08.2007 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie żelaza\nZakres (0,010 – 3,00) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-29, wydanie 1 z dnia 03.08.2007 r. Woda, scieki Stezenie zelaza\nZakres (0,010 – 3,00) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-29, wydanie 1 z dnia 03.08.2007 r.","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Iron concentration Flame atomic absorption spectrometry (FAAS) Range PB-29, wydanie 1 z dnia 03.08.2007 r.","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 3,00) mg/dm3"}],"search_zh":"水、废水 铁浓度 火焰原子吸收光谱法（FAAS） 范围 PB-29, wydanie 1 z dnia 03.08.2007 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水"},{"_id":"6a5dc9c1f1c10c8ce825f5e0","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie potasu","methodology_en":"Potassium concentration","parameters":[{"name":"Zakres","range":"(0,2 – 80) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,2 – 80) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie potasu\nZakres (0,2 – 80) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-39, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 96750","norm_bases":["PB-39, wydanie 1 z dnia 22.12.2010 r.","na podstawie testów HANNA INSTRUMENTS HI 96750"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie potasu\nZakres (0,2 – 80) mg/dm3\nMetoda spektrofotometryczna PB-39, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 96750 Woda Stezenie potasu\nZakres (0,2 – 80) mg/dm3\nMetoda spektrofotometryczna PB-39, wydanie 1 z dnia 22.12.2010 r. | na podstawie testow HANNA INSTRUMENTS HI 96750","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Potassium concentration Spectrophotometric method Range PB-39, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 96750","parameters_zh":[{"name":"范围","range":"(0,2 – 80) mg/dm3"}],"search_zh":"水 钾浓度 分光光度法 范围 PB-39, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 96750","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"钾浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5e1","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(3 – 500) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(3 – 500) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (3 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN- EN ISO 7980:2002","norm_bases":["PN- EN ISO 7980:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wapnia\nZakres (3 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN- EN ISO 7980:2002 Woda Stezenie wapnia\nZakres (3 – 500) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN- EN ISO 7980:2002","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Calcium concentration Flame atomic absorption spectrometry (FAAS) Range PN- EN ISO 7980:2002","parameters_zh":[{"name":"范围","range":"(3 – 500) mg/dm3"}],"search_zh":"水 钙浓度 火焰原子吸收光谱法（FAAS） 范围 PN- EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5e2","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,10 – 2,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-27, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 93729-01","norm_bases":["PB-27, wydanie 1 z dnia 22.12.2010 r.","na podstawie testów HANNA INSTRUMENTS HI 93729-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,10 – 2,00) mg/dm3\nMetoda spektrofotometryczna PB-27, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 93729-01 Woda, woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,10 – 2,00) mg/dm3\nMetoda spektrofotometryczna PB-27, wydanie 1 z dnia 22.12.2010 r. | na podstawie testow HANNA INSTRUMENTS HI 93729-01","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Fluoride concentration Spectrophotometric method Range PB-27, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 93729-01","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) mg/dm3"}],"search_zh":"水、生活饮用水 氟化物浓度 分光光度法 范围 PB-27, wydanie 1 z dnia 22.12.2010 r. | na podstawie testów HANNA INSTRUMENTS HI 93729-01","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5e3","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,04 – 2,80) mg/dm3"},{"name":"Stężenie chloru ogólnego"},{"name":"Zakres","range":"(0,04 – 5,00) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,04 – 2,80) mg/dm3"},{"name":"Total chlorine concentration"},{"name":"Range","range":"(0,04 – 5,00) mg/dm3"}],"technique":"Metoda fotometryczna; Metoda fotometryczna","techniques":["Metoda fotometryczna","Metoda fotometryczna"],"technique_en":"Photometric method; Photometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres:\nZakres (0,04 – 2,80) mg/dm3\nStężenie chloru ogólnego\nZakres (0,04 – 5,00) mg/dm3\nMetoda fotometryczna; Metoda fotometryczna","reference":"PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","norm_bases":["PB-31, wydanie 2 z dnia 20.03.2025 r.","na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres:\nZakres (0,04 – 2,80) mg/dm3\nStężenie chloru ogólnego\nZakres (0,04 – 5,00) mg/dm3\nMetoda fotometryczna; Metoda fotometryczna PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0 Woda, woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres:\nZakres (0,04 – 2,80) mg/dm3\nStezenie chloru ogolnego\nZakres (0,04 – 5,00) mg/dm3\nMetoda fotometryczna; Metoda fotometryczna PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testow HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Free chlorine concentration Photometric method; Photometric method Range Total chlorine concentration Range PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 2,80) mg/dm3"},{"name":"总氯浓度"},{"name":"范围","range":"(0,04 – 5,00) mg/dm3"}],"search_zh":"水、生活饮用水 游离氯浓度 范围 总氯浓度 范围 PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c1f1c10c8ce825f5e4","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","norm_bases":["PB-31, wydanie 2 z dnia 20.03.2025 r.","na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru związanego (z obliczeń) PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0 Woda, woda do spozycia przez ludzi Stezenie chloru zwiazanego (z obliczen) PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testow HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Combined chlorine concentration (calculated) PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","search_zh":"水、生活饮用水 化合氯浓度（计算值） PB-31, wydanie 2 z dnia 20.03.2025 r. | na podstawie testów HANNA INSTRUMENTS HI 93701-0 i HI 93711-0","test_object_zh":"水、生活饮用水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a5dc9c1f1c10c8ce825f5e5","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie magnezu","methodology_en":"Magnesium concentration","parameters":[{"name":"Zakres","range":"(0,90 – 500) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,90 – 500) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie magnezu\nZakres (0,90 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN- EN ISO 7980:2002","norm_bases":["PN- EN ISO 7980:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu\nZakres (0,90 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN- EN ISO 7980:2002 Woda, woda do spozycia przez ludzi Stezenie magnezu\nZakres (0,90 – 500) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN- EN ISO 7980:2002","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Magnesium concentration Flame atomic absorption spectrometry (FAAS) Range PN- EN ISO 7980:2002","parameters_zh":[{"name":"范围","range":"(0,90 – 500) mg/dm3"}],"search_zh":"水、生活饮用水 镁浓度 火焰原子吸收光谱法（FAAS） 范围 PN- EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5e6","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(0,50 – 500) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 500) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (0,50 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+Ap1:2009","norm_bases":["PN-ISO 9964-1:1994+Ap1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie sodu\nZakres (0,50 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009 Woda, woda do spozycia przez ludzi Stezenie sodu\nZakres (0,50 – 500) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+Ap1:2009","parameters_zh":[{"name":"范围","range":"(0,50 – 500) mg/dm3"}],"search_zh":"水、生活饮用水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钠浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5e7","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 750) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 750) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 750) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 750) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 750) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 750) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c1f1c10c8ce825f5e8","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów:","methodology_en":"Concentration of highly volatile halogenated hydrocarbon derivatives:","parameters":[{"name":"Zakres","range":"1,2-dichloroetan (2,0 – 50) μg/dm3"},{"name":"Trichlorometan","range":"(10 – 200) μg/dm3"},{"name":"Bromodichlorometan","range":"(10 – 200) μg/dm3"},{"name":"Dibromochlorometan","range":"(10 – 200) μg/dm3"},{"name":"Tribromometan","range":"(10 – 200) μg/dm3"},{"name":"Trichloroeten","range":"(2,0 – 200) μg/dm3"},{"name":"Tetrachloroeten","range":"(2,0 – 200) μg/dm3"}],"parameters_en":[{"name":"Range","range":"1,2-dichloroetan (2,0 – 50) μg/dm3"},{"name":"Trichloromethane","range":"(10 – 200) μg/dm3"},{"name":"Bromodichloromethane","range":"(10 – 200) μg/dm3"},{"name":"Dibromochloromethane","range":"(10 – 200) μg/dm3"},{"name":"Tribromomethane","range":"(10 – 200) μg/dm3"},{"name":"Trichloroethene","range":"(2,0 – 200) μg/dm3"},{"name":"Tetrachloroethene","range":"(2,0 – 200) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcja wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcja wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów:\nZakres:\nZakres 1,2-dichloroetan (2,0 – 50) μg/dm3\nTrichlorometan (10 – 200) μg/dm3\nBromodichlorometan (10 – 200) μg/dm3\nDibromochlorometan (10 – 200) μg/dm3\nTribromometan (10 – 200) μg/dm3\nTrichloroeten (2,0 – 200) μg/dm3\nTetrachloroeten (2,0 – 200) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronów (GC-ECD)","reference":"PB-36, wydanie 2 z dnia 11.01.2021 r.","norm_bases":["PB-36, wydanie 2 z dnia 11.01.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów:\nZakres:\nZakres 1,2-dichloroetan (2,0 – 50) μg/dm3\nTrichlorometan (10 – 200) μg/dm3\nBromodichlorometan (10 – 200) μg/dm3\nDibromochlorometan (10 – 200) μg/dm3\nTribromometan (10 – 200) μg/dm3\nTrichloroeten (2,0 – 200) μg/dm3\nTetrachloroeten (2,0 – 200) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronów (GC-ECD) PB-36, wydanie 2 z dnia 11.01.2021 r. Woda, woda do spozycia przez ludzi Stezenie latwo lotnych chlorowcowych pochodnych weglowodorow:\nZakres:\nZakres 1,2-dichloroetan (2,0 – 50) μg/dm3\nTrichlorometan (10 – 200) μg/dm3\nBromodichlorometan (10 – 200) μg/dm3\nDibromochlorometan (10 – 200) μg/dm3\nTribromometan (10 – 200) μg/dm3\nTrichloroeten (2,0 – 200) μg/dm3\nTetrachloroeten (2,0 – 200) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PB-36, wydanie 2 z dnia 11.01.2021 r.","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration of highly volatile halogenated hydrocarbon derivatives: Gas chromatography with electron capture detection (GC-ECD) Range Trichloromethane Bromodichloromethane Dibromochloromethane Tribromomethane Trichloroethene Tetrachloroethene PB-36, wydanie 2 z dnia 11.01.2021 r.","parameters_zh":[{"name":"范围","range":"1,2-dichloroetan (2,0 – 50) μg/dm3"},{"name":"三氯甲烷","range":"(10 – 200) μg/dm3"},{"name":"一溴二氯甲烷","range":"(10 – 200) μg/dm3"},{"name":"二溴一氯甲烷","range":"(10 – 200) μg/dm3"},{"name":"三溴甲烷","range":"(10 – 200) μg/dm3"},{"name":"三氯乙烯","range":"(2,0 – 200) μg/dm3"},{"name":"四氯乙烯","range":"(2,0 – 200) μg/dm3"}],"search_zh":"水、生活饮用水 范围 三氯甲烷 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷 三氯乙烯 四氯乙烯 PB-36, wydanie 2 z dnia 11.01.2021 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c1f1c10c8ce825f5e9","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Suma THM (z obliczeń), Suma trichloroetenu i tetrachloroetenu (z obliczeń)","methodology_en":"Sum of THM (calculated), Sum of trichloroethene and tetrachloroethene (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma THM (z obliczeń), Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PB-36, wydanie 2 z dnia 11.01.2021 r.","norm_bases":["PB-36, wydanie 2 z dnia 11.01.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Suma THM (z obliczeń), Suma trichloroetenu i tetrachloroetenu (z obliczeń) PB-36, wydanie 2 z dnia 11.01.2021 r. Woda, woda do spozycia przez ludzi Suma THM (z obliczen), Suma trichloroetenu i tetrachloroetenu (z obliczen) PB-36, wydanie 2 z dnia 11.01.2021 r.","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sum of THM (calculated), Sum of trichloroethene and tetrachloroethene (calculated) PB-36, wydanie 2 z dnia 11.01.2021 r.","search_zh":"水、生活饮用水 PB-36, wydanie 2 z dnia 11.01.2021 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9c1f1c10c8ce825f5ea","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","methodology_en":"Sum of trichloroethene and tetrachloroethene (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PB-36, wydanie 2 z dnia 11.01.2021 r.","norm_bases":["PB-36, wydanie 2 z dnia 11.01.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczeń) PB-36, wydanie 2 z dnia 11.01.2021 r. Woda, woda do spozycia przez ludzi Suma trichloroetenu i tetrachloroetenu (z obliczen) PB-36, wydanie 2 z dnia 11.01.2021 r.","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sum of trichloroethene and tetrachloroethene (calculated) PB-36, wydanie 2 z dnia 11.01.2021 r.","search_zh":"水、生活饮用水 三氯乙烯与四氯乙烯总量（由计算得出） PB-36, wydanie 2 z dnia 11.01.2021 r.","test_object_zh":"水、生活饮用水","methodology_zh":"三氯乙烯与四氯乙烯总量（由计算得出）"},{"_id":"6a5dc9c1f1c10c8ce825f5eb","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali:","methodology_en":"Metal concentrations:","parameters":[{"name":"Zn","range":"(0,001 – 50) mg/dm3"},{"name":"Cu","range":"(0,010 – 3) mg/dm3"},{"name":"Cd","range":"(0,001 – 3) mg/dm3"},{"name":"Ni","range":"(0,010 – 3) mg/dm3"},{"name":"Co","range":"(0,010 – 3) mg/dm3"},{"name":"Mn","range":"(0,010 – 3) mg/dm3"},{"name":"Pb","range":"(0,010 – 3) mg/dm3"}],"parameters_en":[{"name":"Zn","range":"(0,001 – 50) mg/dm3"},{"name":"Cu","range":"(0,010 – 3) mg/dm3"},{"name":"Cd","range":"(0,001 – 3) mg/dm3"},{"name":"Ni","range":"(0,010 – 3) mg/dm3"},{"name":"Co","range":"(0,010 – 3) mg/dm3"},{"name":"Mn","range":"(0,010 – 3) mg/dm3"},{"name":"Pb","range":"(0,010 – 3) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali:\nZakres:\nZn (0,001 – 50) mg/dm3\nCu (0,010 – 3) mg/dm3\nCd (0,001 – 3) mg/dm3\nNi (0,010 – 3) mg/dm3\nCo (0,010 – 3) mg/dm3\nMn (0,010 – 3) mg/dm3\nPb (0,010 – 3) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-10, wydanie 1 z dnia 20.09.2006 r.","norm_bases":["PB-10, wydanie 1 z dnia 20.09.2006 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali:\nZakres:\nZn (0,001 – 50) mg/dm3\nCu (0,010 – 3) mg/dm3\nCd (0,001 – 3) mg/dm3\nNi (0,010 – 3) mg/dm3\nCo (0,010 – 3) mg/dm3\nMn (0,010 – 3) mg/dm3\nPb (0,010 – 3) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10, wydanie 1 z dnia 20.09.2006 r. Woda, scieki Stezenie metali:\nZakres:\nZn (0,001 – 50) mg/dm3\nCu (0,010 – 3) mg/dm3\nCd (0,001 – 3) mg/dm3\nNi (0,010 – 3) mg/dm3\nCo (0,010 – 3) mg/dm3\nMn (0,010 – 3) mg/dm3\nPb (0,010 – 3) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10, wydanie 1 z dnia 20.09.2006 r.","categories":["water","materials"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations: Flame atomic absorption spectrometry (FAAS) Zn Cu Cd Ni Co Mn Pb PB-10, wydanie 1 z dnia 20.09.2006 r.","parameters_zh":[{"name":"Zn","range":"(0,001 – 50) mg/dm3"},{"name":"Cu","range":"(0,010 – 3) mg/dm3"},{"name":"Cd","range":"(0,001 – 3) mg/dm3"},{"name":"Ni","range":"(0,010 – 3) mg/dm3"},{"name":"Co","range":"(0,010 – 3) mg/dm3"},{"name":"Mn","range":"(0,010 – 3) mg/dm3"},{"name":"Pb","range":"(0,010 – 3) mg/dm3"}],"search_zh":"水、废水 金属浓度： 火焰原子吸收光谱法（FAAS） Zn Cu Cd Ni Co Mn Pb PB-10, wydanie 1 z dnia 20.09.2006 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","methodology_zh":"金属浓度："},{"_id":"6a5dc9c1f1c10c8ce825f5ec","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali:","methodology_en":"Metal concentrations:","parameters":[{"name":"Zn","range":"(0,001 – 50,0) mg/dm3"},{"name":"Cu","range":"(0,010 – 3,00) mg/dm3"},{"name":"Cd","range":"(0,001 – 3,00) mg/dm3"},{"name":"Ni","range":"(0,010 – 3,00) mg/dm3"},{"name":"Co","range":"(0,010 – 3,00) mg/dm3"},{"name":"Pb","range":"(0,010 – 3,00) mg/dm3"}],"parameters_en":[{"name":"Zn","range":"(0,001 – 50,0) mg/dm3"},{"name":"Cu","range":"(0,010 – 3,00) mg/dm3"},{"name":"Cd","range":"(0,001 – 3,00) mg/dm3"},{"name":"Ni","range":"(0,010 – 3,00) mg/dm3"},{"name":"Co","range":"(0,010 – 3,00) mg/dm3"},{"name":"Pb","range":"(0,010 – 3,00) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali:\nZakres:\nZn (0,001 – 50,0) mg/dm3\nCu (0,010 – 3,00) mg/dm3\nCd (0,001 – 3,00) mg/dm3\nNi (0,010 – 3,00) mg/dm3\nCo (0,010 – 3,00) mg/dm3\nPb (0,010 – 3,00) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali:\nZakres:\nZn (0,001 – 50,0) mg/dm3\nCu (0,010 – 3,00) mg/dm3\nCd (0,001 – 3,00) mg/dm3\nNi (0,010 – 3,00) mg/dm3\nCo (0,010 – 3,00) mg/dm3\nPb (0,010 – 3,00) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Woda, scieki Stezenie metali:\nZakres:\nZn (0,001 – 50,0) mg/dm3\nCu (0,010 – 3,00) mg/dm3\nCd (0,001 – 3,00) mg/dm3\nNi (0,010 – 3,00) mg/dm3\nCo (0,010 – 3,00) mg/dm3\nPb (0,010 – 3,00) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["water","materials"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations: Flame atomic absorption spectrometry (FAAS) Zn Cu Cd Ni Co Pb PN-ISO 8288:2002","parameters_zh":[{"name":"Zn","range":"(0,001 – 50,0) mg/dm3"},{"name":"Cu","range":"(0,010 – 3,00) mg/dm3"},{"name":"Cd","range":"(0,001 – 3,00) mg/dm3"},{"name":"Ni","range":"(0,010 – 3,00) mg/dm3"},{"name":"Co","range":"(0,010 – 3,00) mg/dm3"},{"name":"Pb","range":"(0,010 – 3,00) mg/dm3"}],"search_zh":"水、废水 金属浓度： 火焰原子吸收光谱法（FAAS） Zn Cu Cd Ni Co Pb PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","methodology_zh":"金属浓度："},{"_id":"6a5dc9c1f1c10c8ce825f5ed","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali:","methodology_en":"Metal concentrations:","parameters":[{"name":"Ca","range":"(3 – 500) mg/dm3"},{"name":"Mg","range":"(0,9 – 500) mg/dm3"}],"parameters_en":[{"name":"Ca","range":"(3 – 500) mg/dm3"},{"name":"Mg","range":"(0,9 – 500) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali:\nZakres:\nCa (3 – 500) mg/dm3\nMg (0,9 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-11, wydanie 1 z dnia 20.09.2006 r.","norm_bases":["PB-11, wydanie 1 z dnia 20.09.2006 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali:\nZakres:\nCa (3 – 500) mg/dm3\nMg (0,9 – 500) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-11, wydanie 1 z dnia 20.09.2006 r. Woda, scieki Stezenie metali:\nZakres:\nCa (3 – 500) mg/dm3\nMg (0,9 – 500) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-11, wydanie 1 z dnia 20.09.2006 r.","categories":["water","materials"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations: Flame atomic absorption spectrometry (FAAS) Ca Mg PB-11, wydanie 1 z dnia 20.09.2006 r.","search_zh":"水、废水 金属浓度： 火焰原子吸收光谱法（FAAS） Ca Mg PB-11, wydanie 1 z dnia 20.09.2006 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","parameters_zh":[{"name":"Ca","range":"(3 – 500) mg/dm3"},{"name":"Mg","range":"(0,9 – 500) mg/dm3"}],"methodology_zh":"金属浓度："},{"_id":"6a5dc9c1f1c10c8ce825f5ee","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(0,50 – 50) oC"}],"parameters_en":[{"name":"Range","range":"(0,50 – 50) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,50 – 50) oC","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.5; 7.6 | PN-ISO 5667-11:2017-10 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.5; 7.6","PN-ISO 5667-11:2017-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,50 – 50) oC PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.5; 7.6 | PN-ISO 5667-11:2017-10 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,50 – 50) oC PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2; 7.5; 7.6 | PN-ISO 5667-11:2017-10 | PN-77/C-04584","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.5; 7.6 | PN-ISO 5667-11:2017-10 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(0,50 – 50) oC"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.5; 7.6 | PN-ISO 5667-11:2017-10 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9c1f1c10c8ce825f5ef","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(0,50 – 50) oC"}],"parameters_en":[{"name":"Range","range":"(0,50 – 50) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,50 – 50) oC","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,50 – 50) oC PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,50 – 50) oC PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(0,50 – 50) oC"}],"search_zh":"生活饮用水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9c1f1c10c8ce825f5f0","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,50 – 50) oC"}],"parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,50 – 50) oC"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,50 – 50) oC\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,50 – 50) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,50 – 50) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,50 – 50) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手工法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a5dc9c1f1c10c8ce825f5f1","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH – w KCl","methodology_en":"pH – in KCl","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH – w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-ISO 10390:2022-09","norm_bases":["PN-ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH – w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-ISO 10390:2022-09 Gleba pH – w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-ISO 10390:2022-09","categories":["environment"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH – in KCl Potentiometric method Range PN-ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"土壤 pH － 于 KCl 中 电位法 范围 PN-ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH － 于 KCl 中"},{"_id":"6a5dc9c1f1c10c8ce825f5f2","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość metali:","methodology_en":"Metal content:","parameters":[{"name":"Zn","range":"(2,5 – 5000) mg/kg"},{"name":"Cu","range":"(2,5 – 900) mg/kg"},{"name":"Pb","range":"(2,5 – 2500) mg/kg"},{"name":"Ni","range":"(2,5 – 800) mg/kg"},{"name":"Mn","range":"(2,5 – 750) mg/kg"},{"name":"Co","range":"(2,5 – 750) mg/kg"},{"name":"Cr","range":"(2,5 – 750) mg/kg"},{"name":"Cd","range":"(2,5 – 750) mg/kg"},{"name":"Fe","range":"(25 – 12500) mg/kg"},{"name":"Na","range":"(125 – 25000) mg/kg"},{"name":"Ca","range":"(250 – 125000) mg/kg"},{"name":"Mg","range":"(250 – 125000) mg/kg"}],"parameters_en":[{"name":"Zn","range":"(2,5 – 5000) mg/kg"},{"name":"Cu","range":"(2,5 – 900) mg/kg"},{"name":"Pb","range":"(2,5 – 2500) mg/kg"},{"name":"Ni","range":"(2,5 – 800) mg/kg"},{"name":"Mn","range":"(2,5 – 750) mg/kg"},{"name":"Co","range":"(2,5 – 750) mg/kg"},{"name":"Cr","range":"(2,5 – 750) mg/kg"},{"name":"Cd","range":"(2,5 – 750) mg/kg"},{"name":"Fe","range":"(25 – 12500) mg/kg"},{"name":"Na","range":"(125 – 25000) mg/kg"},{"name":"Ca","range":"(250 – 125000) mg/kg"},{"name":"Mg","range":"(250 – 125000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Zawartość metali:\nZakres:\nZn (2,5 – 5000) mg/kg\nCu (2,5 – 900) mg/kg\nPb (2,5 – 2500) mg/kg\nNi (2,5 – 800) mg/kg\nMn (2,5 – 750) mg/kg\nCo (2,5 – 750) mg/kg\nCr (2,5 – 750) mg/kg\nCd (2,5 – 750) mg/kg\nFe (25 – 12500) mg/kg\nNa (125 – 25000) mg/kg\nCa (250 – 125000) mg/kg\nMg (250 – 125000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-01(g), wydanie 1 z dnia 03.08.2007 r.","norm_bases":["PB-01(g), wydanie 1 z dnia 03.08.2007 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość metali:\nZakres:\nZn (2,5 – 5000) mg/kg\nCu (2,5 – 900) mg/kg\nPb (2,5 – 2500) mg/kg\nNi (2,5 – 800) mg/kg\nMn (2,5 – 750) mg/kg\nCo (2,5 – 750) mg/kg\nCr (2,5 – 750) mg/kg\nCd (2,5 – 750) mg/kg\nFe (25 – 12500) mg/kg\nNa (125 – 25000) mg/kg\nCa (250 – 125000) mg/kg\nMg (250 – 125000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-01(g), wydanie 1 z dnia 03.08.2007 r. Gleba Zawartosc metali:\nZakres:\nZn (2,5 – 5000) mg/kg\nCu (2,5 – 900) mg/kg\nPb (2,5 – 2500) mg/kg\nNi (2,5 – 800) mg/kg\nMn (2,5 – 750) mg/kg\nCo (2,5 – 750) mg/kg\nCr (2,5 – 750) mg/kg\nCd (2,5 – 750) mg/kg\nFe (25 – 12500) mg/kg\nNa (125 – 25000) mg/kg\nCa (250 – 125000) mg/kg\nMg (250 – 125000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-01(g), wydanie 1 z dnia 03.08.2007 r.","categories":["materials","environment"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Metal content: Flame atomic absorption spectrometry (FAAS) Zn Cu Pb Ni Mn Co Cr Cd Fe Na Ca Mg PB-01(g), wydanie 1 z dnia 03.08.2007 r.","parameters_zh":[{"name":"Zn","range":"(2,5 – 5000) mg/kg"},{"name":"Cu","range":"(2,5 – 900) mg/kg"},{"name":"Pb","range":"(2,5 – 2500) mg/kg"},{"name":"Ni","range":"(2,5 – 800) mg/kg"},{"name":"Mn","range":"(2,5 – 750) mg/kg"},{"name":"Co","range":"(2,5 – 750) mg/kg"},{"name":"Cr","range":"(2,5 – 750) mg/kg"},{"name":"Cd","range":"(2,5 – 750) mg/kg"},{"name":"Fe","range":"(25 – 12500) mg/kg"},{"name":"Na","range":"(125 – 25000) mg/kg"},{"name":"Ca","range":"(250 – 125000) mg/kg"},{"name":"Mg","range":"(250 – 125000) mg/kg"}],"search_zh":"土壤 金属含量： 火焰原子吸收光谱法（FAAS） Zn Cu Pb Ni Mn Co Cr Cd Fe Na Ca Mg PB-01(g), wydanie 1 z dnia 03.08.2007 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"土壤","methodology_zh":"金属含量："},{"_id":"6a5dc9c1f1c10c8ce825f5f3","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Gazy składowiskowe","test_object_en":"Landfill gases","methodology":"Stężenie metanu, dwutlenku węgla, tlenu","methodology_en":"Concentration of methane, carbon dioxide, oxygen","parameters":[{"name":"CH4","range":"(0,1 – 90) %"},{"name":"CO2","range":"(0,1 – 90) %"},{"name":"O2","range":"(0,1 – 21) %"}],"parameters_en":[{"name":"CH4","range":"(0,1 – 90) %"},{"name":"CO2","range":"(0,1 – 90) %"},{"name":"O2","range":"(0,1 – 21) %"}],"technique":"Metoda NDIR; Metoda elektrochemiczna","techniques":["Metoda NDIR","Metoda elektrochemiczna"],"technique_en":"NDIR method; Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie metanu, dwutlenku węgla, tlenu\nZakres:\nCH4 (0,1 – 90) %\nCO2 (0,1 – 90) %\nO2 (0,1 – 21) %\nMetoda NDIR; Metoda elektrochemiczna","reference":"PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-03 (p), wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy składowiskowe Stężenie metanu, dwutlenku węgla, tlenu\nZakres:\nCH4 (0,1 – 90) %\nCO2 (0,1 – 90) %\nO2 (0,1 – 21) %\nMetoda NDIR; Metoda elektrochemiczna PB-03 (p), wydanie 3 z dnia 01.02.2021 r. Gazy skladowiskowe Stezenie metanu, dwutlenku wegla, tlenu\nZakres:\nCH4 (0,1 – 90) %\nCO2 (0,1 – 90) %\nO2 (0,1 – 21) %\nMetoda NDIR; Metoda elektrochemiczna PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","categories":["other"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Landfill gases Concentration of methane, carbon dioxide, oxygen NDIR method; Electrochemical method CH4 CO2 O2 PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","parameters_zh":[{"name":"CH4","range":"(0,1 – 90) %"},{"name":"CO2","range":"(0,1 – 90) %"},{"name":"O2","range":"(0,1 – 21) %"}],"search_zh":"填埋场气体 CO2 O2 PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"填埋场气体"},{"_id":"6a5dc9c1f1c10c8ce825f5f4","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Gazy składowiskowe","test_object_en":"Landfill gases","methodology":"Prędkość","methodology_en":"Velocity","parameters":[{"name":"Zakres","range":"(0,1 - 5,0) m/s"}],"parameters_en":[{"name":"Range","range":"(0,1 - 5,0) m/s"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"technique_en":"Thermoanemometric method","computed":[],"computed_en":[],"activity":"Prędkość\nZakres (0,1 - 5,0) m/s\nMetoda termoanemometryczna","reference":"PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-03 (p), wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy składowiskowe Prędkość\nZakres (0,1 - 5,0) m/s\nMetoda termoanemometryczna PB-03 (p), wydanie 3 z dnia 01.02.2021 r. Gazy skladowiskowe Predkosc\nZakres (0,1 - 5,0) m/s\nMetoda termoanemometryczna PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","categories":["other"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Landfill gases Velocity Thermoanemometric method Range PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","parameters_zh":[{"name":"范围","range":"(0,1 - 5,0) m/s"}],"search_zh":"填埋场气体 速度 热线风速仪法 范围 PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"填埋场气体","methodology_zh":"速度","technique_zh":"热线风速仪法"},{"_id":"6a5dc9c1f1c10c8ce825f5f5","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Gazy składowiskowe","test_object_en":"Landfill gases","methodology":"Emisja CH4, CO2, O2 (z obliczeń)","methodology_en":"Emission of CH4, CO2, O2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CH4, CO2, O2 (z obliczeń)","reference":"PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","norm_bases":["PB-03 (p), wydanie 3 z dnia 01.02.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy składowiskowe Emisja CH4, CO2, O2 (z obliczeń) PB-03 (p), wydanie 3 z dnia 01.02.2021 r. Gazy skladowiskowe Emisja CH4, CO2, O2 (z obliczen) PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","categories":["environment"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Landfill gases Emission of CH4, CO2, O2 (calculated) PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","search_zh":"填埋场气体 PB-03 (p), wydanie 3 z dnia 01.02.2021 r.","test_object_zh":"填埋场气体"},{"_id":"6a5dc9c1f1c10c8ce825f5f6","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(25 – 110) dB"}],"parameters_en":[{"name":"Range","range":"(25 – 110) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 110) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 110) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 110) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 110) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9c1f1c10c8ce825f5f7","lab_id":"69ad52a3de79e566650fb474","country":"PL","accr_number":"AB 885","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"}],"has_pdf":true}