{"lab":{"_id":"69ad52a3de79e566650fb472","accr_number":"AB 883","country":"PL","accr_body":"PCA","address":"WYDZIAŁ LABORATORIÓW CHEMICZNYCH, Świerże Górne, ul. Aleja Józefa Zielińskiego 1, 26-900 Kozienice","categories":["water","petro","materials","environment"],"city":"Kozienice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":71,"name":"ENEA WYTWARZANIE SP. Z O.O.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_883.pdf"],"scope_summary":"","search_text":"enea wytwarzanie sp. z o.o. wydział laboratoriów chemicznych, świerże górne, ul. aleja józefa zielińskiego 1, 26-900 kozienice petro other environment food materials water pharma electronics","status":"active","updated_at":"2026-03-08T14:51:46.527Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:46.527Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20883,podmiot.html","fields_of_testing":[{"codes":"C/5/P","pl":"Badania chemiczne i pobieranie próbek materiałów budowlanych","en":"Chemical tests and sampling of buildings materials"},{"codes":"C/28/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, odpadów","en":"Chemical tests and sampling of water, sewage, waste"},{"codes":"C/10/P","pl":"Badania chemiczne i pobieranie próbek paliw stałych","en":"Chemical tests and sampling of solid fuels"},{"codes":"C/10; C/46","pl":"Badania chemiczne paliw ciekłych, materiałów smarnych","en":"Chemical tests of liquid fuels, lubricants"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek materiałów budowlanych","en":"Tests of physical properties and sampling of buildings materials"},{"codes":"N/28/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, odpadów","en":"Tests of physical properties and sampling of water, sewage, waste"},{"codes":"N/10/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw stałych","en":"Tests of physical properties and sampling of solid fuels"},{"codes":"N/10; N/46","pl":"Badania właściwości fizycznych paliw ciekłych i materiałów smarnych","en":"Tests of physical properties of liquid fuels, lubricants"}],"issue":{"no":"27","date":"16.12.2025"},"parse_date":"2026-07-20T07:09:53.439Z","parse_source":"script-pdfplumber","map_coord":[51.661425,21.470357],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":32,"petro":28,"materials":9,"environment":7,"other":6},"category_scores":{"water":12.49,"petro":9.56,"materials":0.99,"environment":0.6,"other":0.44},"has_zh":true},"methods":[{"_id":"6a5dc9c1f1c10c8ce825f571","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN G-04502:2014-11 pkt. 5.3.1.3; 5.3.1.4; 5.3.4; 5.3.6","norm_bases":["PN G-04502:2014-11 pkt. 5.3.1.3; 5.3.1.4; 5.3.4; 5.3.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN G-04502:2014-11 pkt. 5.3.1.3; 5.3.1.4; 5.3.4; 5.3.6 Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN G-04502:2014-11 pkt. 5.3.1.3; 5.3.1.4; 5.3.4; 5.3.6","categories":["petro"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN G-04502:2014-11 pkt. 5.3.1.3; 5.3.1.4; 5.3.4; 5.3.6","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN G-04502:2014-11 pkt. 5.3.1.3; 5.3.1.4; 5.3.4; 5.3.6","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f572","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(2,0 – 20,0) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (2,0 – 20,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda B1","norm_bases":["PN-ISO 589:2006 Metoda B1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (2,0 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda B1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (2,0 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda B1","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-ISO 589:2006 Metoda B1","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 20,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-ISO 589:2006 Metoda B1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f573","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(2,0 – 25,0) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (2,0 – 25,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06 | ISO 589:2008-11 Metoda B1","norm_bases":["PN-G-04611:2020-06","ISO 589:2008-11 Metoda B1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (2,0 – 25,0) %\nMetoda wagowa PN-G-04611:2020-06 | ISO 589:2008-11 Metoda B1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (2,0 – 25,0) %\nMetoda wagowa PN-G-04611:2020-06 | ISO 589:2008-11 Metoda B1","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06 | ISO 589:2008-11 Metoda B1","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 25,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06 | ISO 589:2008-11 Metoda B1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f574","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02","test_object_en":"Waste code: 10 01 01, 10 01 02","methodology":"Pobieranie próbek popiołu lotnego do badań chemicznych i fizycznych","methodology_en":"Sampling of fly ash for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek popiołu lotnego do badań chemicznych i fizycznych\nMetoda manualna","reference":"PB-16 edycja 09 z dnia 09.10.2019 r.","norm_bases":["PB-16 edycja 09 z dnia 09.10.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 01, 10 01 02 Pobieranie próbek popiołu lotnego do badań chemicznych i fizycznych\nMetoda manualna PB-16 edycja 09 z dnia 09.10.2019 r. Odpady kod: 10 01 01, 10 01 02 Pobieranie probek popiolu lotnego do badan chemicznych i fizycznych\nMetoda manualna PB-16 edycja 09 z dnia 09.10.2019 r.","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 01, 10 01 02 Sampling of fly ash for chemical and physical testing Manual method PB-16 edycja 09 z dnia 09.10.2019 r.","search_zh":"废物代码：10 01 01、10 01 02 手工法 PB-16 edycja 09 z dnia 09.10.2019 r.","technique_zh":"手工法","test_object_zh":"废物代码：10 01 01、10 01 02"},{"_id":"6a5dc9c1f1c10c8ce825f575","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02","test_object_en":"Waste code: 10 01 01, 10 01 02","methodology":"Pobieranie próbek popiołu lotnego do badań chemicznych i fizycznych","methodology_en":"Sampling of fly ash for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda automatyczna","techniques":["Metoda automatyczna"],"technique_en":"Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek popiołu lotnego do badań chemicznych i fizycznych\nMetoda automatyczna","reference":"PB-26 edycja 05 z dnia 09.10.2019 r.","norm_bases":["PB-26 edycja 05 z dnia 09.10.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 01, 10 01 02 Pobieranie próbek popiołu lotnego do badań chemicznych i fizycznych\nMetoda automatyczna PB-26 edycja 05 z dnia 09.10.2019 r. Odpady kod: 10 01 01, 10 01 02 Pobieranie probek popiolu lotnego do badan chemicznych i fizycznych\nMetoda automatyczna PB-26 edycja 05 z dnia 09.10.2019 r.","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 01, 10 01 02 Sampling of fly ash for chemical and physical testing Automatic method PB-26 edycja 05 z dnia 09.10.2019 r.","search_zh":"废物代码：10 01 01、10 01 02 自动法 PB-26 edycja 05 z dnia 09.10.2019 r.","technique_zh":"自动法","test_object_zh":"废物代码：10 01 01、10 01 02"},{"_id":"6a5dc9c1f1c10c8ce825f576","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Odpady kod: 10 01 01, 10 01 02","test_object_en":"Waste code: 10 01 01, 10 01 02","methodology":"Pobieranie próbek żużla do badań chemicznych i fizycznych","methodology_en":"Slag sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek żużla do badań chemicznych i fizycznych\nMetoda manualna","reference":"PB-21 edycja 08 z dnia 09.10.2019 r.","norm_bases":["PB-21 edycja 08 z dnia 09.10.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 01, 10 01 02 Pobieranie próbek żużla do badań chemicznych i fizycznych\nMetoda manualna PB-21 edycja 08 z dnia 09.10.2019 r. Odpady kod: 10 01 01, 10 01 02 Pobieranie probek zuzla do badan chemicznych i fizycznych\nMetoda manualna PB-21 edycja 08 z dnia 09.10.2019 r.","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 01, 10 01 02 Slag sampling for chemical and physical testing Manual method PB-21 edycja 08 z dnia 09.10.2019 r.","search_zh":"废物代码：10 01 01、10 01 02 手工法 PB-21 edycja 08 z dnia 09.10.2019 r.","technique_zh":"手工法","test_object_zh":"废物代码：10 01 01、10 01 02"},{"_id":"6a5dc9c1f1c10c8ce825f577","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,6 – 8,5) %"}],"parameters_en":[{"name":"Range","range":"(0,6 – 8,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,6 – 8,5) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,6 – 8,5) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,6 – 8,5) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,6 – 8,5) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f578","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,60 – 4,00) %"}],"parameters_en":[{"name":"Range","range":"(0,60 – 4,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,60 – 4,00) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,60 – 4,00) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,60 – 4,00) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,60 – 4,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f579","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,60 – 8,50) %"}],"parameters_en":[{"name":"Range","range":"(0,60 – 8,50) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,60 – 8,50) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,60 – 8,50) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,60 – 8,50) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,60 – 8,50) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f57a","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(3,50 – 46,00) %"}],"parameters_en":[{"name":"Range","range":"(3,50 – 46,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (3,50 – 46,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (3,50 – 46,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (3,50 – 46,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(3,50 – 46,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f57b","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(20,00 – 40,00) %"}],"parameters_en":[{"name":"Range","range":"(20,00 – 40,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (20,00 – 40,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (20,00 – 40,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (20,00 – 40,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Volatile matter content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(20,00 – 40,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a5dc9c1f1c10c8ce825f57c","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(3,5 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(3,5 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (3,5 – 50,0) %\nMetoda wagowa","reference":"PN-80/G-04512+Az1:2002 z wył. pkt. 2.4.2","norm_bases":["PN-80/G-04512+Az1:2002 z wył. pkt. 2.4.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (3,5 – 50,0) %\nMetoda wagowa PN-80/G-04512+Az1:2002 z wył. pkt. 2.4.2 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (3,5 – 50,0) %\nMetoda wagowa PN-80/G-04512+Az1:2002 z wyl. pkt. 2.4.2","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-80/G-04512+Az1:2002 z wył. pkt. 2.4.2","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(3,5 – 50,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-80/G-04512+Az1:2002 z wył. pkt. 2.4.2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f57d","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(6,0 – 35,0)%"}],"parameters_en":[{"name":"Range","range":"(6,0 – 35,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (6,0 – 35,0)%\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (6,0 – 35,0)%\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (6,0 – 35,0)%\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(6,0 – 35,0)%"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f57e","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość części lotnych","methodology_en":"Volatile matter content","parameters":[{"name":"Zakres","range":"(20,00 – 40,00) %"}],"parameters_en":[{"name":"Range","range":"(20,00 – 40,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość części lotnych\nZakres (20,00 – 40,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (20,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (20,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","parameters_zh":[{"name":"范围","range":"(20,00 – 40,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a5dc9c1f1c10c8ce825f57f","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f580","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,10 – 1,40) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 1,40) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 1,40) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 1,40) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 1,40) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range ISO 19579:2006","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 1,40) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f581","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(16000 – 35000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(16000 – 35000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (16000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | ISO 1928:2025-08","norm_bases":["PN-81/G-04513","ISO 1928:2025-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (16000 – 35000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 | ISO 1928:2025-08 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (16000 – 35000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513 | ISO 1928:2025-08","categories":["petro"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-81/G-04513 | ISO 1928:2025-08","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(16000 – 35000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-81/G-04513 | ISO 1928:2025-08","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f582","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(40,0 – 85,0) %"}],"parameters_en":[{"name":"Range","range":"(40,0 – 85,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (40,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (40,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (40,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(40,0 – 85,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f583","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(45,0 – 83,0) %"}],"parameters_en":[{"name":"Range","range":"(45,0 – 83,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (45,0 – 83,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2010","norm_bases":["ISO 29541:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (45,0 – 83,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2010 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (45,0 – 83,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2010","categories":["petro"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range ISO 29541:2010","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(45,0 – 83,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 ISO 29541:2010","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f584","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(3,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a5dc9c1f1c10c8ce825f585","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(3,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2010","norm_bases":["ISO 29541:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2010 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2010","categories":["petro"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range ISO 29541:2010","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 ISO 29541:2010","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a5dc9c1f1c10c8ce825f586","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,80 – 2,10) %"}],"parameters_en":[{"name":"Range","range":"(0,80 – 2,10) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,80 – 2,10) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998 | ISO 29541:2010","norm_bases":["PN-G-04571:1998","ISO 29541:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,80 – 2,10) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 | ISO 29541:2010 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,80 – 2,10) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998 | ISO 29541:2010","categories":["petro"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range PN-G-04571:1998 | ISO 29541:2010","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,80 – 2,10) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 PN-G-04571:1998 | ISO 29541:2010","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a5dc9c1f1c10c8ce825f587","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,040 – 0,300) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,040 – 0,300) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,040 – 0,300) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"EPA Method 7473:2007","norm_bases":["EPA Method 7473:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość rtęci\nZakres (0,040 – 0,300) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji EPA Method 7473:2007 Paliwa stale: wegiel kamienny Zawartosc rteci\nZakres (0,040 – 0,300) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji EPA Method 7473:2007","categories":["petro"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Mercury content Atomic absorption spectrometry with amalgamation technique Range EPA Method 7473:2007","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,040 – 0,300) mg/kg"}],"search_zh":"固体燃料：烟煤 汞含量 原子吸收光谱法（汞齐化技术） 范围 EPA Method 7473:2007","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9c1f1c10c8ce825f588","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02","test_object_en":"Waste: code 10 01 01, 10 01 02","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,05 – 0,50) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 0,50) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,05 – 0,50) %\nMetoda wagowa","reference":"PB-06 edycja 07 z dnia 12.09.2019 r.","norm_bases":["PB-06 edycja 07 z dnia 12.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01, 10 01 02 Zawartość wilgoci analitycznej\nZakres (0,05 – 0,50) %\nMetoda wagowa PB-06 edycja 07 z dnia 12.09.2019 r. Odpady: kod 10 01 01, 10 01 02 Zawartosc wilgoci analitycznej\nZakres (0,05 – 0,50) %\nMetoda wagowa PB-06 edycja 07 z dnia 12.09.2019 r.","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01, 10 01 02 Analytical moisture content Gravimetric method Range PB-06 edycja 07 z dnia 12.09.2019 r.","parameters_zh":[{"name":"范围","range":"(0,05 – 0,50) %"}],"search_zh":"分析水分含量 重量法 范围 PB-06 edycja 07 z dnia 12.09.2019 r.","technique_zh":"重量法","methodology_zh":"分析水分含量"},{"_id":"6a5dc9c1f1c10c8ce825f589","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02","test_object_en":"Waste: code 10 01 01, 10 01 02","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,10 – 30,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 30,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (0,10 – 30,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB-02 edycja 09 z dnia 23.10.2023 r.","norm_bases":["PB-02 edycja 09 z dnia 23.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01, 10 01 02 Zawartość węgla całkowitego\nZakres (0,10 – 30,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB-02 edycja 09 z dnia 23.10.2023 r. Odpady: kod 10 01 01, 10 01 02 Zawartosc wegla calkowitego\nZakres (0,10 – 30,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB-02 edycja 09 z dnia 23.10.2023 r.","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01, 10 01 02 Total carbon content High-temperature combustion with IR detection Range PB-02 edycja 09 z dnia 23.10.2023 r.","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,10 – 30,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PB-02 edycja 09 z dnia 23.10.2023 r.","technique_zh":"高温燃烧红外检测法"},{"_id":"6a5dc9c1f1c10c8ce825f58a","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Odpady: kod 10 01 02","test_object_en":"Waste: code 10 01 02","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,05 – 0,65) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 0,65) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,05 – 0,65) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 02 Zawartość wilgoci analitycznej\nZakres (0,05 – 0,65) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Odpady: kod 10 01 02 Zawartosc wilgoci analitycznej\nZakres (0,05 – 0,65) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 02 Analytical moisture content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(0,05 – 0,65) %"}],"search_zh":"分析水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","methodology_zh":"分析水分含量"},{"_id":"6a5dc9c1f1c10c8ce825f58b","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Odpady: kod 10 01 01","test_object_en":"Waste: code 10 01 01","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,05 – 1,65) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,65) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,05 – 1,65) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 10 01 01 Zawartość wilgoci analitycznej\nZakres (0,05 – 1,65) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Odpady: kod 10 01 01 Zawartosc wilgoci analitycznej\nZakres (0,05 – 1,65) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 10 01 01 Analytical moisture content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(0,05 – 1,65) %"}],"search_zh":"分析水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","methodology_zh":"分析水分含量"},{"_id":"6a5dc9c1f1c10c8ce825f58c","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki","test_object_en":"Liquid fuels: heavy fuel oil","methodology":"Gęstość w temp. 15°C i 60 °C","methodology_en":"Density at temp. 15°C and 60 °C","parameters":[{"name":"Zakres","range":"(870,0 – 1000,0) kg/m3"}],"parameters_en":[{"name":"Range","range":"(870,0 – 1000,0) kg/m3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"technique_en":"Oscillation method","computed":[],"computed_en":[],"activity":"Gęstość w temp. 15°C i 60 °C\nZakres (870,0 – 1000,0) kg/m3\nMetoda oscylacyjna","reference":"PN-EN ISO 12185:2024-08","norm_bases":["PN-EN ISO 12185:2024-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa ciekłe: olej opałowy ciężki Gęstość w temp. 15°C i 60 °C\nZakres (870,0 – 1000,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08 Paliwa ciekle: olej opalowy ciezki Gestosc w temp. 15°C i 60 °C\nZakres (870,0 – 1000,0) kg/m3\nMetoda oscylacyjna PN-EN ISO 12185:2024-08","categories":["petro"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid fuels: heavy fuel oil Density at temp. 15°C and 60 °C Oscillation method Range PN-EN ISO 12185:2024-08","parameters_zh":[{"name":"范围","range":"(870,0 – 1000,0) kg/m3"}],"search_zh":"液体燃料：重燃料油 振荡法 范围 PN-EN ISO 12185:2024-08","technique_zh":"振荡法","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a5dc9c1f1c10c8ce825f58d","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe","test_object_en":"Lubricants: industrial lubricating oils","methodology":"Zawartość wody","methodology_en":"Water content","parameters":[{"name":"Zakres","range":"(0,003 – 0,100) % (m/m)"}],"parameters_en":[{"name":"Range","range":"(0,003 – 0,100) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"technique_en":"Coulometric titration method","computed":[],"computed_en":[],"activity":"Zawartość wody\nZakres (0,003 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PN-EN ISO 12937:2005+Ap1: 2021-11 z wyłączeniem pkt. 6.2.5, 6.2.6, 6.2.7, 6.2.8","norm_bases":["PN-EN ISO 12937:2005+Ap1: 2021-11 z wyłączeniem pkt. 6.2.5, 6.2.6, 6.2.7, 6.2.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały smarne: przemysłowe oleje smarowe Zawartość wody\nZakres (0,003 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1: 2021-11 z wyłączeniem pkt. 6.2.5, 6.2.6, 6.2.7, 6.2.8 Materialy smarne: przemyslowe oleje smarowe Zawartosc wody\nZakres (0,003 – 0,100) % (m/m)\nMetoda miareczkowania kulometrycznego PN-EN ISO 12937:2005+Ap1: 2021-11 z wylaczeniem pkt. 6.2.5, 6.2.6, 6.2.7, 6.2.8","categories":["materials","petro","water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lubricants: industrial lubricating oils Water content Coulometric titration method Range PN-EN ISO 12937:2005+Ap1: 2021-11 z wyłączeniem pkt. 6.2.5, 6.2.6, 6.2.7, 6.2.8","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,100) % (m/m)"}],"search_zh":"润滑材料：工业润滑油 水分含量 库仑滴定法 范围 PN-EN ISO 12937:2005+Ap1: 2021-11 z wyłączeniem pkt. 6.2.5, 6.2.6, 6.2.7, 6.2.8","technique_zh":"库仑滴定法","test_object_zh":"润滑材料：工业润滑油"},{"_id":"6a5dc9c1f1c10c8ce825f58e","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe","test_object_en":"Lubricants: industrial lubricating oils","methodology":"Lepkość kinematyczna w temp. 40 °C i 100 °C","methodology_en":"Kinematic viscosity at 40 °C and 100 °C","parameters":[{"name":"Zakres","range":"(3,000 – 1200) mm2/s"}],"parameters_en":[{"name":"Range","range":"(3,000 – 1200) mm2/s"}],"technique":"Metoda kapilarna","techniques":["Metoda kapilarna"],"technique_en":"Capillary method","computed":[],"computed_en":[],"activity":"Lepkość kinematyczna w temp. 40 °C i 100 °C\nZakres (3,000 – 1200) mm2/s\nMetoda kapilarna","reference":"ASTM D445-23 | PN-EN ISO 3104:2024-01 Procedura B","norm_bases":["ASTM D445-23","PN-EN ISO 3104:2024-01 Procedura B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały smarne: przemysłowe oleje smarowe Lepkość kinematyczna w temp. 40 °C i 100 °C\nZakres (3,000 – 1200) mm2/s\nMetoda kapilarna ASTM D445-23 | PN-EN ISO 3104:2024-01 Procedura B Materialy smarne: przemyslowe oleje smarowe Lepkosc kinematyczna w temp. 40 °C i 100 °C\nZakres (3,000 – 1200) mm2/s\nMetoda kapilarna ASTM D445-23 | PN-EN ISO 3104:2024-01 Procedura B","categories":["materials","petro"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lubricants: industrial lubricating oils Kinematic viscosity at 40 °C and 100 °C Capillary method Range ASTM D445-23 | PN-EN ISO 3104:2024-01 Procedura B","parameters_zh":[{"name":"范围","range":"(3,000 – 1200) mm2/s"}],"search_zh":"润滑材料：工业润滑油 毛细管法 范围 ASTM D445-23 | PN-EN ISO 3104:2024-01 Procedura B","technique_zh":"毛细管法","test_object_zh":"润滑材料：工业润滑油"},{"_id":"6a5dc9c1f1c10c8ce825f58f","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe","test_object_en":"Lubricants: industrial lubricating oils","methodology":"Wskaźnik lepkości (z obliczeń)","methodology_en":"Viscosity index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik lepkości (z obliczeń)","reference":"PN-ISO 2909:2009+Ap1:2010","norm_bases":["PN-ISO 2909:2009+Ap1:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały smarne: przemysłowe oleje smarowe Wskaźnik lepkości (z obliczeń) PN-ISO 2909:2009+Ap1:2010 Materialy smarne: przemyslowe oleje smarowe Wskaznik lepkosci (z obliczen) PN-ISO 2909:2009+Ap1:2010","categories":["materials","petro"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lubricants: industrial lubricating oils Viscosity index (calculated) PN-ISO 2909:2009+Ap1:2010","methodology_zh":"黏度指数（由计算得出）","search_zh":"润滑材料：工业润滑油 黏度指数（由计算得出） PN-ISO 2909:2009+Ap1:2010","test_object_zh":"润滑材料：工业润滑油"},{"_id":"6a5dc9c1f1c10c8ce825f590","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe","test_object_en":"Lubricants: industrial lubricating oils","methodology":"Temperatura zapłonu","methodology_en":"Flash point","parameters":[{"name":"Zakres","range":"(200 – 330) °C"}],"parameters_en":[{"name":"Range","range":"(200 – 330) °C"}],"technique":"Metoda otwartego tygla Clevelanda","techniques":["Metoda otwartego tygla Clevelanda"],"technique_en":"Cleveland open cup method","computed":[],"computed_en":[],"activity":"Temperatura zapłonu\nZakres (200 – 330) °C\nMetoda otwartego tygla Clevelanda","reference":"PN-EN ISO 2592:2017-10 z wyłączeniem pkt.11","norm_bases":["PN-EN ISO 2592:2017-10 z wyłączeniem pkt.11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały smarne: przemysłowe oleje smarowe Temperatura zapłonu\nZakres (200 – 330) °C\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 z wyłączeniem pkt.11 Materialy smarne: przemyslowe oleje smarowe Temperatura zaplonu\nZakres (200 – 330) °C\nMetoda otwartego tygla Clevelanda PN-EN ISO 2592:2017-10 z wylaczeniem pkt.11","categories":["materials","petro"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lubricants: industrial lubricating oils Flash point Cleveland open cup method Range PN-EN ISO 2592:2017-10 z wyłączeniem pkt.11","parameters_zh":[{"name":"范围","range":"(200 – 330) °C"}],"search_zh":"润滑材料：工业润滑油 闪点 克利夫兰开口杯法 范围 PN-EN ISO 2592:2017-10 z wyłączeniem pkt.11","methodology_zh":"闪点","technique_zh":"克利夫兰开口杯法","test_object_zh":"润滑材料：工业润滑油"},{"_id":"6a5dc9c1f1c10c8ce825f591","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe","test_object_en":"Lubricants: industrial lubricating oils","methodology":"Liczba kwasowa","methodology_en":"Acid value","parameters":[{"name":"Zakres","range":"(0,05 – 1,40) mg KOH/g"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,40) mg KOH/g"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Liczba kwasowa\nZakres (0,05 – 1,40) mg KOH/g\nMetoda miareczkowania potencjometrycznego","reference":"ASTM D664:24 Metoda A","norm_bases":["ASTM D664:24 Metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały smarne: przemysłowe oleje smarowe Liczba kwasowa\nZakres (0,05 – 1,40) mg KOH/g\nMetoda miareczkowania potencjometrycznego ASTM D664:24 Metoda A Materialy smarne: przemyslowe oleje smarowe Liczba kwasowa\nZakres (0,05 – 1,40) mg KOH/g\nMetoda miareczkowania potencjometrycznego ASTM D664:24 Metoda A","categories":["materials","petro"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lubricants: industrial lubricating oils Acid value Potentiometric titration method Range ASTM D664:24 Metoda A","parameters_zh":[{"name":"范围","range":"(0,05 – 1,40) mg KOH/g"}],"search_zh":"润滑材料：工业润滑油 酸值 电位滴定法 范围 ASTM D664:24 Metoda A","technique_zh":"电位滴定法","methodology_zh":"酸值","test_object_zh":"润滑材料：工业润滑油"},{"_id":"6a5dc9c1f1c10c8ce825f592","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe","test_object_en":"Lubricants: industrial lubricating oils","methodology":"Zawartość wody","methodology_en":"Water content","parameters":[{"name":"Zakres","range":"(0,003 – 0,200) % (m/m)"}],"parameters_en":[{"name":"Range","range":"(0,003 – 0,200) % (m/m)"}],"technique":"Metoda miareczkowania kulometrycznego","techniques":["Metoda miareczkowania kulometrycznego"],"technique_en":"Coulometric titration method","computed":[],"computed_en":[],"activity":"Zawartość wody\nZakres (0,003 – 0,200) % (m/m)\nMetoda miareczkowania kulometrycznego","reference":"PB-36 edycja 03 z dnia 12.09.2019 r.","norm_bases":["PB-36 edycja 03 z dnia 12.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały smarne: przemysłowe oleje smarowe Zawartość wody\nZakres (0,003 – 0,200) % (m/m)\nMetoda miareczkowania kulometrycznego PB-36 edycja 03 z dnia 12.09.2019 r. Materialy smarne: przemyslowe oleje smarowe Zawartosc wody\nZakres (0,003 – 0,200) % (m/m)\nMetoda miareczkowania kulometrycznego PB-36 edycja 03 z dnia 12.09.2019 r.","categories":["materials","petro","water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lubricants: industrial lubricating oils Water content Coulometric titration method Range PB-36 edycja 03 z dnia 12.09.2019 r.","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,003 – 0,200) % (m/m)"}],"search_zh":"润滑材料：工业润滑油 水分含量 库仑滴定法 范围 PB-36 edycja 03 z dnia 12.09.2019 r.","technique_zh":"库仑滴定法","test_object_zh":"润滑材料：工业润滑油"},{"_id":"6a5dc9c1f1c10c8ce825f593","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Materiały smarne: przemysłowe oleje smarowe","test_object_en":"Lubricants: industrial lubricating oils","methodology":"Zawartość zanieczyszczeń: ≥ 5μm","methodology_en":"Content of impurities: ≥ 5μm","parameters":[{"name":"Zakres","range":"(1 – 1 000 000) cząstek/100ml"},{"name":"≥ 15μm"},{"name":"Zakres","range":"(1 – 150 000) cząstek/ 100ml"},{"name":"Kod liczbowy zanieczyszczeń"},{"name":"Zakres","range":"(1 – 20)"}],"parameters_en":[{"name":"Range","range":"(1 – 1 000 000) cząstek/100ml"},{"name":"≥ 15μm"},{"name":"Range","range":"(1 – 150 000) cząstek/ 100ml"},{"name":"Numerical contamination code"},{"name":"Range","range":"(1 – 20)"}],"technique":"Metoda zliczania za pomocą mikroskopu optycznego; Metoda kodowania","techniques":["Metoda zliczania za pomocą mikroskopu optycznego","Metoda kodowania"],"technique_en":"Counting method using an optical microscope; Coding method","computed":[],"computed_en":[],"activity":"Zawartość zanieczyszczeń: ≥ 5μm\nZakres:\nZakres (1 – 1 000 000) cząstek/100ml\n≥ 15μm\nZakres (1 – 150 000) cząstek/ 100ml\nKod liczbowy zanieczyszczeń\nZakres (1 – 20)\nMetoda zliczania za pomocą mikroskopu optycznego; Metoda kodowania","reference":"PN-ISO 4407:2021-03 z wyłączeniem pkt 9.5 | PN-ISO 4406:2005 z wyłączeniem pkt. 3.4","norm_bases":["PN-ISO 4407:2021-03 z wyłączeniem pkt 9.5","PN-ISO 4406:2005 z wyłączeniem pkt. 3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały smarne: przemysłowe oleje smarowe Zawartość zanieczyszczeń: ≥ 5μm\nZakres:\nZakres (1 – 1 000 000) cząstek/100ml\n≥ 15μm\nZakres (1 – 150 000) cząstek/ 100ml\nKod liczbowy zanieczyszczeń\nZakres (1 – 20)\nMetoda zliczania za pomocą mikroskopu optycznego; Metoda kodowania PN-ISO 4407:2021-03 z wyłączeniem pkt 9.5 | PN-ISO 4406:2005 z wyłączeniem pkt. 3.4 Materialy smarne: przemyslowe oleje smarowe Zawartosc zanieczyszczen: ≥ 5μm\nZakres:\nZakres (1 – 1 000 000) czastek/100ml\n≥ 15μm\nZakres (1 – 150 000) czastek/ 100ml\nKod liczbowy zanieczyszczen\nZakres (1 – 20)\nMetoda zliczania za pomoca mikroskopu optycznego; Metoda kodowania PN-ISO 4407:2021-03 z wylaczeniem pkt 9.5 | PN-ISO 4406:2005 z wylaczeniem pkt. 3.4","categories":["materials","petro"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Lubricants: industrial lubricating oils Content of impurities: ≥ 5μm Counting method using an optical microscope; Coding method Range ≥ 15μm Range Numerical contamination code Range PN-ISO 4407:2021-03 z wyłączeniem pkt 9.5 | PN-ISO 4406:2005 z wyłączeniem pkt. 3.4","parameters_zh":[{"name":"范围","range":"(1 – 1 000 000) cząstek/100ml"},{"name":"≥ 15μm"},{"name":"范围","range":"(1 – 150 000) cząstek/ 100ml"},{"name":"Kod liczbowy zanieczyszczeń"},{"name":"范围","range":"(1 – 20)"}],"search_zh":"润滑材料：工业润滑油 范围 范围 范围 PN-ISO 4407:2021-03 z wyłączeniem pkt 9.5 | PN-ISO 4406:2005 z wyłączeniem pkt. 3.4","test_object_zh":"润滑材料：工业润滑油"},{"_id":"6a5dc9c1f1c10c8ce825f594","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"parameters_en":[{"name":"Range","range":"(0,0 – 50,0) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) oC","reference":"PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,0 – 50,0) oC PN-EN ISO 5667-6:2016-12 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,0 – 50,0) oC PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a5dc9c1f1c10c8ce825f595","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczynów","methodology_en":"Sulfite concentration","parameters":[{"name":"Zakres","range":"(0,025 – 25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,025 – 25) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie siarczynów\nZakres (0,025 – 25) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-3:2001","norm_bases":["PN-EN ISO 10304-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczynów\nZakres (0,025 – 25) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-3:2001 Woda Stezenie siarczynow\nZakres (0,025 – 25) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-3:2001","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sulfite concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-3:2001","parameters_zh":[{"name":"范围","range":"(0,025 – 25) mg/l"}],"search_zh":"水 亚硫酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-3:2001","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","methodology_zh":"亚硫酸盐浓度"},{"_id":"6a5dc9c1f1c10c8ce825f596","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,0 – 50,0) oC"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,0 – 50,0) oC"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 50,0) oC\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,0 – 50,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,0 – 50,0) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,0 – 50,0) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9c1f1c10c8ce825f597","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczynów","methodology_en":"Sulfite concentration","parameters":[{"name":"Zakres","range":"(0,50 – 25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 25) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie siarczynów\nZakres (0,50 – 25) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-3:2001","norm_bases":["PN-EN ISO 10304-3:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczynów\nZakres (0,50 – 25) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-3:2001 Scieki Stezenie siarczynow\nZakres (0,50 – 25) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-3:2001","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sulfite concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 10304-3:2001","parameters_zh":[{"name":"范围","range":"(0,50 – 25) mg/l"}],"search_zh":"污水 亚硫酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 10304-3:2001","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","methodology_zh":"亚硫酸盐浓度"},{"_id":"6a5dc9c1f1c10c8ce825f598","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f599","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f59a","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa PN-EN 1899-2:2002","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Titrimetric method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 滴定法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f59b","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014","norm_bases":["PN-EN 1899-2:2002 z wył. pkt. 7.2","ISO 17289:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyl. pkt. 7.2 | ISO 17289:2014","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Optical method BOD5 Range PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f59c","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 250) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 250) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Titrimetric method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 250) mg/l O2"}],"search_zh":"水、污水 生化需氧量 滴定法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f59d","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 250) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 250) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 250) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 250) mg/l O2"}],"search_zh":"水、污水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f59e","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(10 – 200) mg/l O2"}],"parameters_en":[{"name":"COD"},{"name":"Range","range":"(10 – 200) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10 – 200) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10 – 200) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (10 – 200) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Titrimetric method COD Range PN-ISO 6060:2006","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(10 – 200) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 滴定法 化学需氧量（COD） 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c1f1c10c8ce825f59f","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,050 – 10,0) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,064 – 13,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 10,0) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,064 – 13,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,050 – 10,0) mg/l\nStężenie jonu amonowego\nZakres (0,064 – 13,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,050 – 10,0) mg/l\nStężenie jonu amonowego\nZakres (0,064 – 13,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,050 – 10,0) mg/l\nStezenie jonu amonowego\nZakres (0,064 – 13,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 10,0) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,064 – 13,0) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 铵离子浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a0","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(1,29 – 129) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(1,29 – 129) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 100) mg/l\nStężenie jonu amonowego\nZakres (1,29 – 129) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres:\nZakres (1,0 – 100) mg/l\nStężenie jonu amonowego\nZakres (1,29 – 129) mg/l\nMetoda miareczkowania potencjometrycznego PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres:\nZakres (1,0 – 100) mg/l\nStezenie jonu amonowego\nZakres (1,29 – 129) mg/l\nMetoda miareczkowania potencjometrycznego PN-ISO 5664:2002","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Potentiometric titration method Range Ammonium ion concentration Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(1,29 – 129) mg/l"}],"search_zh":"水、污水 氨氮浓度 电位滴定法 范围 铵离子浓度 范围 PN-ISO 5664:2002","technique_zh":"电位滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a1","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 150) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 150) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 150) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Potentiometric titration method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 电位滴定法 范围 PN-EN 25663:2001","technique_zh":"电位滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a2","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,10 – 850) mg/l"},{"name":"Stężenie azotu azotanowego"},{"name":"Zakres","range":"(0,025 – 192) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 850) mg/l"},{"name":"Nitrate nitrogen concentration"},{"name":"Range","range":"(0,025 – 192) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres:\nZakres (0,10 – 850) mg/l\nStężenie azotu azotanowego\nZakres (0,025 – 192) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotanów\nZakres:\nZakres (0,10 – 850) mg/l\nStężenie azotu azotanowego\nZakres (0,025 – 192) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie azotanow\nZakres:\nZakres (0,10 – 850) mg/l\nStezenie azotu azotanowego\nZakres (0,025 – 192) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate concentration Ion chromatography with conductometric detection (IC-CD) Range Nitrate nitrogen concentration Range PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 850) mg/l"},{"name":"硝态氮浓度"},{"name":"范围","range":"(0,025 – 192) mg/l"}],"search_zh":"水、污水 硝酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 硝态氮浓度 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a3","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,033 – 32,8) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,033 – 32,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStężenie azotynów\nZakres (0,033 – 32,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStężenie azotynów\nZakres (0,033 – 32,8) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,010 – 10,0) mg/l\nStezenie azotynow\nZakres (0,033 – 32,8) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,033 – 32,8) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a4","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a5","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"Fluorki","range":"(0,050 – 15,0) mg/l"},{"name":"Chlorki","range":"(1,0 – 30000) mg/l"},{"name":"Siarczany","range":"(1,0 – 3000) mg/l"}],"parameters_en":[{"name":"Fluorides","range":"(0,050 – 15,0) mg/l"},{"name":"Chlorides","range":"(1,0 – 30000) mg/l"},{"name":"Sulfates","range":"(1,0 – 3000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nFluorki (0,050 – 15,0) mg/l\nChlorki (1,0 – 30000) mg/l\nSiarczany (1,0 – 3000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie anionów\nZakres:\nFluorki (0,050 – 15,0) mg/l\nChlorki (1,0 – 30000) mg/l\nSiarczany (1,0 – 3000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow\nZakres:\nFluorki (0,050 – 15,0) mg/l\nChlorki (1,0 – 30000) mg/l\nSiarczany (1,0 – 3000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Fluorides Chlorides Sulfates PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氟化物","range":"(0,050 – 15,0) mg/l"},{"name":"氯化物","range":"(1,0 – 30000) mg/l"},{"name":"硫酸盐","range":"(1,0 – 3000) mg/l"}],"search_zh":"水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a6","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Arsen","range":"(0,0050 – 5,00) mg/l"},{"name":"Bor","range":"(0,020 – 500) mg/l"},{"name":"Kadm","range":"(0,0050 – 5,00) mg/l"},{"name":"Chrom","range":"(0,0050 – 5,00) mg/l"},{"name":"Miedź","range":"(0,0050 – 5,00) mg/l"},{"name":"Mangan","range":"(0,0050 – 5,00) mg/l"},{"name":"Nikiel","range":"(0,0050 – 5,00) mg/l"},{"name":"Srebro","range":"(0,0050 – 5,00) mg/l"},{"name":"Ołów","range":"(0,010 – 5,00) mg/l"},{"name":"Wanad","range":"(0,0050 – 5,00) mg/l"},{"name":"Cynk","range":"(0,0050 – 5,00) mg/l"}],"parameters_en":[{"name":"Arsenic","range":"(0,0050 – 5,00) mg/l"},{"name":"Boron","range":"(0,020 – 500) mg/l"},{"name":"Cadmium","range":"(0,0050 – 5,00) mg/l"},{"name":"Chromium","range":"(0,0050 – 5,00) mg/l"},{"name":"Copper","range":"(0,0050 – 5,00) mg/l"},{"name":"Manganese","range":"(0,0050 – 5,00) mg/l"},{"name":"Nickel","range":"(0,0050 – 5,00) mg/l"},{"name":"Silver","range":"(0,0050 – 5,00) mg/l"},{"name":"Lead","range":"(0,010 – 5,00) mg/l"},{"name":"Vanadium","range":"(0,0050 – 5,00) mg/l"},{"name":"Zinc","range":"(0,0050 – 5,00) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nArsen (0,0050 – 5,00) mg/l\nBor (0,020 – 500) mg/l\nKadm (0,0050 – 5,00) mg/l\nChrom (0,0050 – 5,00) mg/l\nMiedź (0,0050 – 5,00) mg/l\nMangan (0,0050 – 5,00) mg/l\nNikiel (0,0050 – 5,00) mg/l\nSrebro (0,0050 – 5,00) mg/l\nOłów (0,010 – 5,00) mg/l\nWanad (0,0050 – 5,00) mg/l\nCynk (0,0050 – 5,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nArsen (0,0050 – 5,00) mg/l\nBor (0,020 – 500) mg/l\nKadm (0,0050 – 5,00) mg/l\nChrom (0,0050 – 5,00) mg/l\nMiedź (0,0050 – 5,00) mg/l\nMangan (0,0050 – 5,00) mg/l\nNikiel (0,0050 – 5,00) mg/l\nSrebro (0,0050 – 5,00) mg/l\nOłów (0,010 – 5,00) mg/l\nWanad (0,0050 – 5,00) mg/l\nCynk (0,0050 – 5,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie pierwiastkow\nZakres:\nArsen (0,0050 – 5,00) mg/l\nBor (0,020 – 500) mg/l\nKadm (0,0050 – 5,00) mg/l\nChrom (0,0050 – 5,00) mg/l\nMiedz (0,0050 – 5,00) mg/l\nMangan (0,0050 – 5,00) mg/l\nNikiel (0,0050 – 5,00) mg/l\nSrebro (0,0050 – 5,00) mg/l\nOlow (0,010 – 5,00) mg/l\nWanad (0,0050 – 5,00) mg/l\nCynk (0,0050 – 5,00) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Arsenic Boron Cadmium Chromium Copper Manganese Nickel Silver Lead Vanadium Zinc PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"砷","range":"(0,0050 – 5,00) mg/l"},{"name":"硼","range":"(0,020 – 500) mg/l"},{"name":"镉","range":"(0,0050 – 5,00) mg/l"},{"name":"铬","range":"(0,0050 – 5,00) mg/l"},{"name":"铜","range":"(0,0050 – 5,00) mg/l"},{"name":"锰","range":"(0,0050 – 5,00) mg/l"},{"name":"镍","range":"(0,0050 – 5,00) mg/l"},{"name":"银","range":"(0,0050 – 5,00) mg/l"},{"name":"铅","range":"(0,010 – 5,00) mg/l"},{"name":"钒","range":"(0,0050 – 5,00) mg/l"},{"name":"锌","range":"(0,0050 – 5,00) mg/l"}],"search_zh":"水、污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 硼 镉 铬 铜 锰 镍 银 铅 钒 锌 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5a7","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(4 – 300) mg/l O2"}],"parameters_en":[{"name":"COD"},{"name":"Range","range":"(4 – 300) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4 – 300) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4 – 300) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4 – 300) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Spectrophotometric method COD Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(4 – 300) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 分光光度法 化学需氧量（COD） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9c1f1c10c8ce825f5a8","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,2 – 20,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,2 – 20,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997 Woda, Scieki Stezenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dissolved oxygen concentration Titrimetric method Range PN-EN 25813:1997","parameters_zh":[{"name":"范围","range":"(0,2 – 20,0) mg/l O2"}],"search_zh":"水、污水 溶解氧浓度 滴定法 范围 PN-EN 25813:1997","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5a9","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,2 – 20,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,2 – 20,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda, Scieki Stezenie tlenu rozpuszczonego\nZakres (0,2 – 20,0) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dissolved oxygen concentration Optical method Range ISO 17289:2014","parameters_zh":[{"name":"范围","range":"(0,2 – 20,0) mg/l O2"}],"search_zh":"水、污水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5aa","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(0,10 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 200) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcja IR","techniques":["Metoda wysokotemperaturowego spalania z detekcja IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,10 – 200) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,10 – 200) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (0,10 – 200) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration (TOC) High-temperature combustion with IR detection Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(0,10 – 200) mg/l"}],"search_zh":"水、污水 总有机碳浓度（TOC） 高温燃烧-红外检测法 范围 PN-EN 1484:1999","test_object_zh":"水、污水","methodology_zh":"总有机碳浓度（TOC）","technique_zh":"高温燃烧-红外检测法"},{"_id":"6a5dc9c1f1c10c8ce825f5ab","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"technique_en":"High-temperature combustion with chemiluminescence detection","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 200) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (1,0 – 200) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-05 Woda, Scieki Stezenie azotu ogolnego\nZakres (1,0 – 200) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration High-temperature combustion with chemiluminescence detection Range PN-EN ISO 20236:2025-05","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/l"}],"search_zh":"水、污水 总氮浓度 高温燃烧-化学发光检测法 范围 PN-EN ISO 20236:2025-05","test_object_zh":"水、污水","technique_zh":"高温燃烧-化学发光检测法"},{"_id":"6a5dc9c1f1c10c8ce825f5ac","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,050 – 500) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 500) μg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (AFS)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (AFS)"],"technique_en":"Atomic fluorescence spectrometry (AFS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,050 – 500) μg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres (0,050 – 500) μg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009 Woda, Scieki Stezenie rteci\nZakres (0,050 – 500) μg/l\nMetoda atomowej spektrometrii fluorescencyjnej (AFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Mercury concentration Atomic fluorescence spectrometry (AFS) Range PN-EN ISO 17852:2009","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 500) μg/l"}],"search_zh":"水、污水 汞浓度 原子荧光光谱法（AFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"水、污水","technique_zh":"原子荧光光谱法（AFS）"},{"_id":"6a5dc9c1f1c10c8ce825f5ad","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 200) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (1,0 – 200) mg/l\nMetoda wagowa PN-86/C-04573/01 Woda, Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (1,0 – 200) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573/01","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/l"}],"search_zh":"水、污水 石油醚可萃取物浓度 重量法 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9c1f1c10c8ce825f5ae","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,010 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 2,0) mg/l"}],"technique":"Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","techniques":["Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną"],"technique_en":"Flow injection analysis (FIA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,010 – 2,0) mg/l\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004","norm_bases":["PN-EN ISO 14402:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,010 – 2,0) mg/l\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 Woda, Scieki Indeks fenolowy\nZakres (0,010 – 2,0) mg/l\nMetoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index Flow injection analysis (FIA) with spectrophotometric detection Range PN-EN ISO 14402:2004","parameters_zh":[{"name":"范围","range":"(0,010 – 2,0) mg/l"}],"search_zh":"水、污水 酚指数 流动注射分析（FIA）分光光度检测法 范围 PN-EN ISO 14402:2004","test_object_zh":"水、污水","methodology_zh":"酚指数","technique_zh":"流动注射分析（FIA）分光光度检测法"},{"_id":"6a5dc9c1f1c10c8ce825f5af","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Kadm","range":"(0,0002 – 5,00) mg/l"},{"name":"Arsen","range":"(0,0010 – 5,00) mg/l"},{"name":"Chrom","range":"(0,0010 – 5,00) mg/l"},{"name":"Miedź","range":"(0,0010 – 5,00) mg/l"},{"name":"Nikiel","range":"(0,0010 – 5,00) mg/l"},{"name":"Srebro","range":"(0,0010 – 1,00) mg/l"},{"name":"Ołów","range":"(0,0010 – 5,00) mg/l"},{"name":"Wanad","range":"(0,0010 – 5,00) mg/l"},{"name":"Cynk","range":"(0,0010 – 10,00) mg/l"}],"parameters_en":[{"name":"Cadmium","range":"(0,0002 – 5,00) mg/l"},{"name":"Arsenic","range":"(0,0010 – 5,00) mg/l"},{"name":"Chromium","range":"(0,0010 – 5,00) mg/l"},{"name":"Copper","range":"(0,0010 – 5,00) mg/l"},{"name":"Nickel","range":"(0,0010 – 5,00) mg/l"},{"name":"Silver","range":"(0,0010 – 1,00) mg/l"},{"name":"Lead","range":"(0,0010 – 5,00) mg/l"},{"name":"Vanadium","range":"(0,0010 – 5,00) mg/l"},{"name":"Zinc","range":"(0,0010 – 10,00) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nKadm (0,0002 – 5,00) mg/l\nArsen (0,0010 – 5,00) mg/l\nChrom (0,0010 – 5,00) mg/l\nMiedź (0,0010 – 5,00) mg/l\nNikiel (0,0010 – 5,00) mg/l\nSrebro (0,0010 – 1,00) mg/l\nOłów (0,0010 – 5,00) mg/l\nWanad (0,0010 – 5,00) mg/l\nCynk (0,0010 – 10,00) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nKadm (0,0002 – 5,00) mg/l\nArsen (0,0010 – 5,00) mg/l\nChrom (0,0010 – 5,00) mg/l\nMiedź (0,0010 – 5,00) mg/l\nNikiel (0,0010 – 5,00) mg/l\nSrebro (0,0010 – 1,00) mg/l\nOłów (0,0010 – 5,00) mg/l\nWanad (0,0010 – 5,00) mg/l\nCynk (0,0010 – 10,00) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, Scieki Stezenie pierwiastkow\nZakres:\nKadm (0,0002 – 5,00) mg/l\nArsen (0,0010 – 5,00) mg/l\nChrom (0,0010 – 5,00) mg/l\nMiedz (0,0010 – 5,00) mg/l\nNikiel (0,0010 – 5,00) mg/l\nSrebro (0,0010 – 1,00) mg/l\nOlow (0,0010 – 5,00) mg/l\nWanad (0,0010 – 5,00) mg/l\nCynk (0,0010 – 10,00) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Cadmium Arsenic Chromium Copper Nickel Silver Lead Vanadium Zinc PN-EN ISO 17294-2:2024-04","methodology_zh":"元素浓度","parameters_zh":[{"name":"镉","range":"(0,0002 – 5,00) mg/l"},{"name":"砷","range":"(0,0010 – 5,00) mg/l"},{"name":"铬","range":"(0,0010 – 5,00) mg/l"},{"name":"铜","range":"(0,0010 – 5,00) mg/l"},{"name":"镍","range":"(0,0010 – 5,00) mg/l"},{"name":"银","range":"(0,0010 – 1,00) mg/l"},{"name":"铅","range":"(0,0010 – 5,00) mg/l"},{"name":"钒","range":"(0,0010 – 5,00) mg/l"},{"name":"锌","range":"(0,0010 – 10,00) mg/l"}],"search_zh":"水、污水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 镉 砷 铬 铜 镍 银 铅 钒 锌 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5b0","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczków łatwo uwalnianych","methodology_en":"Concentration of readily released sulphides","parameters":[{"name":"Zakres","range":"(0,05 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczków łatwo uwalnianych\nZakres (0,05 – 10) mg/l\nMetoda spektrofotometryczna","reference":"ISO 13358:1997","norm_bases":["ISO 13358:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczków łatwo uwalnianych\nZakres (0,05 – 10) mg/l\nMetoda spektrofotometryczna ISO 13358:1997 Woda, Scieki Stezenie siarczkow latwo uwalnianych\nZakres (0,05 – 10) mg/l\nMetoda spektrofotometryczna ISO 13358:1997","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of readily released sulphides Spectrophotometric method Range ISO 13358:1997","parameters_zh":[{"name":"范围","range":"(0,05 – 10) mg/l"}],"search_zh":"水、污水 分光光度法 范围 ISO 13358:1997","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5b1","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(200 – 5000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(200 – 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (200 – 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (200 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (200 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(200 – 5000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a5dc9c1f1c10c8ce825f5b2","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Mączka kamienia wapiennego","test_object_en":"Limestone meal","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PB-18 edycja 09 z dnia 12.09.2019 r.","norm_bases":["PB-18 edycja 09 z dnia 12.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mączka kamienia wapiennego Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PB-18 edycja 09 z dnia 12.09.2019 r. Maczka kamienia wapiennego Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PB-18 edycja 09 z dnia 12.09.2019 r.","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Limestone meal Sampling for chemical and physical testing Manual method PB-18 edycja 09 z dnia 12.09.2019 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"石灰石粉 化学与物理检测用样品采集 手工法 PB-18 edycja 09 z dnia 12.09.2019 r.","technique_zh":"手工法","test_object_zh":"石灰石粉"},{"_id":"6a5dc9c1f1c10c8ce825f5b3","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Mączka kamienia wapiennego","test_object_en":"Limestone meal","methodology":"Strata prażenia","methodology_en":"Loss on ignition","parameters":[{"name":"Zakres","range":"(40,00 – 45,00) %"}],"parameters_en":[{"name":"Range","range":"(40,00 – 45,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Strata prażenia\nZakres (40,00 – 45,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mączka kamienia wapiennego Strata prażenia\nZakres (40,00 – 45,00) %\nMetoda termograwimetryczna (TGA) PN-EN 196-2:2013-11 Maczka kamienia wapiennego Strata prazenia\nZakres (40,00 – 45,00) %\nMetoda termograwimetryczna (TGA) PN-EN 196-2:2013-11","categories":["other"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Limestone meal Loss on ignition Thermogravimetric method (TGA) Range PN-EN 196-2:2013-11","parameters_zh":[{"name":"范围","range":"(40,00 – 45,00) %"}],"search_zh":"石灰石粉 烧失量 热重法（TGA） 范围 PN-EN 196-2:2013-11","technique_zh":"热重法（TGA）","methodology_zh":"烧失量","test_object_zh":"石灰石粉"},{"_id":"6a5dc9c1f1c10c8ce825f5b4","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Mączka kamienia wapiennego","test_object_en":"Limestone meal","methodology":"Zawartość CaO","methodology_en":"CaO content","parameters":[{"name":"Zakres","range":"(52,00 – 55,70) %"},{"name":"Zawartość CaCO3 z obliczeń Zawartość MgO"},{"name":"Zakres","range":"(0,10 – 2,10) %"},{"name":"Zawartość MgCO3 z obliczeń WD-XRF"}],"parameters_en":[{"name":"Range","range":"(52,00 – 55,70) %"},{"name":"CaCO3 content calculated MgO content"},{"name":"Range","range":"(0,10 – 2,10) %"},{"name":"MgCO3 content calculated WD-XRF"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali"],"technique_en":"Wavelength-dispersive X-ray fluorescence spectrometry","computed":[],"computed_en":[],"activity":"Zawartość CaO\nZakres:\nZakres (52,00 – 55,70) %\nZawartość CaCO3 z obliczeń Zawartość MgO\nZakres (0,10 – 2,10) %\nZawartość MgCO3 z obliczeń WD-XRF\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mączka kamienia wapiennego Zawartość CaO\nZakres:\nZakres (52,00 – 55,70) %\nZawartość CaCO3 z obliczeń Zawartość MgO\nZakres (0,10 – 2,10) %\nZawartość MgCO3 z obliczeń WD-XRF\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali PN-EN 196-2:2013-11 Maczka kamienia wapiennego Zawartosc CaO\nZakres:\nZakres (52,00 – 55,70) %\nZawartosc CaCO3 z obliczen Zawartosc MgO\nZakres (0,10 – 2,10) %\nZawartosc MgCO3 z obliczen WD-XRF\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali PN-EN 196-2:2013-11","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Limestone meal CaO content Wavelength-dispersive X-ray fluorescence spectrometry Range CaCO3 content calculated MgO content Range MgCO3 content calculated WD-XRF PN-EN 196-2:2013-11","parameters_zh":[{"name":"范围","range":"(52,00 – 55,70) %"},{"name":"Zawartość CaCO3 z obliczeń Zawartość MgO"},{"name":"范围","range":"(0,10 – 2,10) %"},{"name":"Zawartość MgCO3 z obliczeń WD-XRF"}],"search_zh":"石灰石粉 CaO 含量 波长色散X射线荧光光谱法 范围 范围 PN-EN 196-2:2013-11","methodology_zh":"CaO 含量","technique_zh":"波长色散X射线荧光光谱法","test_object_zh":"石灰石粉"},{"_id":"6a5dc9c1f1c10c8ce825f5b5","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Mączka kamienia wapiennego","test_object_en":"Limestone meal","methodology":"Zawartość CaO","methodology_en":"CaO content","parameters":[{"name":"Zakres","range":"(52,00 – 55,70) %"},{"name":"Zawartość CaCO3 z obliczeń Zawartość MgO"},{"name":"Zakres","range":"(0,10 – 2,10) %"},{"name":"Zawartość MgCO3 z obliczeń ED-XRF"}],"parameters_en":[{"name":"Range","range":"(52,00 – 55,70) %"},{"name":"CaCO3 content calculated MgO content"},{"name":"Range","range":"(0,10 – 2,10) %"},{"name":"MgCO3 content calculated ED-XRF"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii"],"technique_en":"Energy-dispersive X-ray fluorescence spectrometry","computed":[],"computed_en":[],"activity":"Zawartość CaO\nZakres:\nZakres (52,00 – 55,70) %\nZawartość CaCO3 z obliczeń Zawartość MgO\nZakres (0,10 – 2,10) %\nZawartość MgCO3 z obliczeń ED-XRF\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mączka kamienia wapiennego Zawartość CaO\nZakres:\nZakres (52,00 – 55,70) %\nZawartość CaCO3 z obliczeń Zawartość MgO\nZakres (0,10 – 2,10) %\nZawartość MgCO3 z obliczeń ED-XRF\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii PN-EN 196-2:2013-11 Maczka kamienia wapiennego Zawartosc CaO\nZakres:\nZakres (52,00 – 55,70) %\nZawartosc CaCO3 z obliczen Zawartosc MgO\nZakres (0,10 – 2,10) %\nZawartosc MgCO3 z obliczen ED-XRF\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii PN-EN 196-2:2013-11","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Limestone meal CaO content Energy-dispersive X-ray fluorescence spectrometry Range CaCO3 content calculated MgO content Range MgCO3 content calculated ED-XRF PN-EN 196-2:2013-11","parameters_zh":[{"name":"范围","range":"(52,00 – 55,70) %"},{"name":"Zawartość CaCO3 z obliczeń Zawartość MgO"},{"name":"范围","range":"(0,10 – 2,10) %"},{"name":"Zawartość MgCO3 z obliczeń ED-XRF"}],"search_zh":"石灰石粉 CaO 含量 能量色散X射线荧光光谱法 范围 范围 PN-EN 196-2:2013-11","technique_zh":"能量色散X射线荧光光谱法","methodology_zh":"CaO 含量","test_object_zh":"石灰石粉"},{"_id":"6a5dc9c1f1c10c8ce825f5b6","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Gips","test_object_en":"Gypsum","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PB-19 edycja 07 z dnia 12.09.2019 r.","norm_bases":["PB-19 edycja 07 z dnia 12.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gips Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PB-19 edycja 07 z dnia 12.09.2019 r. Gips Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PB-19 edycja 07 z dnia 12.09.2019 r.","categories":["other"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gypsum Sampling for chemical and physical testing Manual method PB-19 edycja 07 z dnia 12.09.2019 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"石膏 化学与物理检测用样品采集 手工法 PB-19 edycja 07 z dnia 12.09.2019 r.","technique_zh":"手工法","test_object_zh":"石膏"},{"_id":"6a5dc9c1f1c10c8ce825f5b7","lab_id":"69ad52a3de79e566650fb472","country":"PL","accr_number":"AB 883","accr_body":"PCA","test_object":"Gips","test_object_en":"Gypsum","methodology":"Zawartość węglanów wapnia i magnezu","methodology_en":"Content of calcium and magnesium carbonates","parameters":[{"name":"Zakres","range":"(0,20 – 10,00) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 10,00) %"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"technique_en":"Potentiometric titration method","computed":[],"computed_en":[],"activity":"Zawartość węglanów wapnia i magnezu\nZakres (0,20 – 10,00) %\nMetoda miareczkowania potencjometrycznego","reference":"PB-04 edycja 06 z dnia 12.09.2019 r.","norm_bases":["PB-04 edycja 06 z dnia 12.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gips Zawartość węglanów wapnia i magnezu\nZakres (0,20 – 10,00) %\nMetoda miareczkowania potencjometrycznego PB-04 edycja 06 z dnia 12.09.2019 r. Gips Zawartosc weglanow wapnia i magnezu\nZakres (0,20 – 10,00) %\nMetoda miareczkowania potencjometrycznego PB-04 edycja 06 z dnia 12.09.2019 r.","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Gypsum Content of calcium and magnesium carbonates Potentiometric titration method Range PB-04 edycja 06 z dnia 12.09.2019 r.","parameters_zh":[{"name":"范围","range":"(0,20 – 10,00) %"}],"search_zh":"石膏 电位滴定法 范围 PB-04 edycja 06 z dnia 12.09.2019 r.","technique_zh":"电位滴定法","test_object_zh":"石膏"}],"has_pdf":true}