{"lab":{"_id":"69ad52a3de79e566650fb46e","accr_number":"AB 880","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADANIA ŚCIEKÓW, Kałdowo Wieś, 82-200 Malbork","categories":["water"],"city":"Malbork","imported_at":"2026-03-08T10:42:43.265Z","methods_count":8,"name":"PRZEDSIĘBIORSTWO „NOGAT” Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_880.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo „nogat” sp. z o.o. laboratorium badania ścieków, kałdowo wieś, 82-200 malbork water other","status":"active","updated_at":"2026-03-08T14:51:46.201Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:12:32.881Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20880,podmiot.html","fields_of_testing":[{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"}],"issue":{"no":"17","date":"25.05.2026"},"parse_date":"2026-08-13T08:12:32.881Z","parse_source":"agent-claude-code","map_coord":[54.035836,19.03685],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM BADANIA ŚCIEKÓW","address":"82-200 Kamionka","city":"Kamionka","postal":"82-200"},{"name":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/28001fcd83be880052a3e599328b69c6/AB%20880.pdf","has_en":true,"category_counts":{"water":8},"category_scores":{"water":8},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM BADANIA ŚCIEKÓW","address":"82-200 Kamionka","city":"Kamionka","postal":"82-200"},{"name":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7c700636ba417e41c596","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"},{"_id":"6a7d7c700636ba417e41c597","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 9,0"}],"search_en":"Wastewater pH Potentiometric method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 9,0"}],"search_zh":"污水 pH 值 电位法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"},{"_id":"6a7d7c700636ba417e41c598","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6,0) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6,0) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6,0) mg/dm3 O2"}],"search_zh":"污水 生化需氧量 电化学法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"},{"_id":"6a7d7c700636ba417e41c599","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3,0 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3,0 – 6000) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3,0 – 6000) mg/dm3 O2"}],"search_zh":"污水 生化需氧量 电化学法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"},{"_id":"6a7d7c700636ba417e41c59a","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10,0 – 15000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 15000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 15000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 15000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10,0 – 15000) mg/dm3 O2"}],"search_en":"Wastewater Chemical oxygen demand Spectrophotometric method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10,0 – 15000) mg/dm3 O2"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"},{"_id":"6a7d7c700636ba417e41c59b","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 3000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 3000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/dm3"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/dm3"}],"search_zh":"污水 总悬浮物 重量法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"},{"_id":"6a7d7c700636ba417e41c59c","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu całkowitego","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu całkowitego\nZakres (1,0 – 150) mg/dm3\nMetoda spektrofotometryczna","reference":"PB nr 1/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14763.0001 i 1.00613.0001","norm_bases":["PB nr 1/06 wydanie 4 z dnia 28.01.2010 r.","na podstawie testu Merck Nr 1.14763.0001 i 1.00613.0001"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu całkowitego\nZakres (1,0 – 150) mg/dm3\nMetoda spektrofotometryczna PB nr 1/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14763.0001 i 1.00613.0001 Scieki Stezenie azotu calkowitego\nZakres (1,0 – 150) mg/dm3\nMetoda spektrofotometryczna PB nr 1/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14763.0001 i 1.00613.0001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/dm3"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka Range PB nr 1/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14763.0001 i 1.00613.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/dm3"}],"search_zh":"污水 分光光度法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 范围 PB nr 1/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14763.0001 i 1.00613.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"},{"_id":"6a7d7c700636ba417e41c59d","lab_id":"69ad52a3de79e566650fb46e","country":"PL","accr_number":"AB 880","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,20 – 25,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,20 – 25,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PB nr 3/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14543.0001 i 1.14729.0001","norm_bases":["PB nr 3/06 wydanie 4 z dnia 28.01.2010 r.","na podstawie testu Merck Nr 1.14543.0001 i 1.14729.0001"],"lab_section":"Laboratorium Badania Ścieków; Kamionka 101, 82-200 Kamionka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,20 – 25,0) mg/dm3\nMetoda spektrofotometryczna PB nr 3/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14543.0001 i 1.14729.0001 Scieki Stezenie fosforu ogolnego\nZakres (0,20 – 25,0) mg/dm3\nMetoda spektrofotometryczna PB nr 3/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14543.0001 i 1.14729.0001","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,20 – 25,0) mg/dm3"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Wastewater Testing Laboratory; Kamionka 101, 82-200 Kamionka Range PB nr 3/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14543.0001 i 1.14729.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 25,0) mg/dm3"}],"search_zh":"污水 总磷浓度 分光光度法 废水检验实验室；Kamionka 101, 82-200 卡米翁卡 范围 PB nr 3/06 wydanie 4 z dnia 28.01.2010 r. | na podstawie testu Merck Nr 1.14543.0001 i 1.14729.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"废水检验实验室；Kamionka 101, 82-200 卡米翁卡"}],"has_pdf":true}