{"lab":{"_id":"69ad52a3de79e566650fb464","accr_number":"AB 871","country":"PL","accr_body":"PCA","address":"BADANIE ŚRODOWISKA PRACY. USŁUGI W ZAKRESIE BHP, Dorota Zielińska, ul. Jana III Sobieskiego 6, 74-400 Dębno","categories":["environment","construction","materials"],"city":"Dębno","imported_at":"2026-03-08T10:42:43.265Z","methods_count":12,"name":"AKUSTYKA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_871.pdf"],"scope_summary":"","search_text":"akustyka badanie środowiska pracy. usługi w zakresie bhp, dorota zielińska, ul. jana iii sobieskiego 6, 74-400 dębno other environment materials construction electronics","status":"active","updated_at":"2026-03-08T14:51:45.644Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:45.644Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20871,podmiot.html","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests – working environment (harmful factors – air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, microclimate)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment (harmful factors – air)"}],"parse_date":"2026-07-20T07:09:52.982Z","parse_source":"script-pdfplumber","map_coord":[52.746368,14.697416],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":12,"construction":2,"materials":1},"category_scores":{"environment":9.6,"construction":0.27,"materials":0.07},"has_zh":true},"methods":[{"_id":"6a5dc9c0f1c10c8ce825f3a5","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(25 - 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(25 - 136) dB"}],"parameters_en":[{"name":"Range","range":"(25 - 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(25 - 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 - 136) dB\nSzczytowy poziom dźwięku C\nZakres (25 - 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 - 136) dB\nSzczytowy poziom dźwięku C\nZakres (25 - 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 - 136) dB\nSzczytowy poziom dzwieku C\nZakres (25 - 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych Strategie 2 p. 10 i Strategie 3 p. 11","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25 - 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(25 - 136) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9c0f1c10c8ce825f3a6","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Poziom ekspozycji na hałas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do: − 8-godz. dobowego wymiaru czasu pracy − przecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych Strategie 2 p. 10 i Strategie 3 p. 11","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise Noise exposure level referred to: − an 8-hour daily working time − an average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","search_zh":"工作环境 − 噪声 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 p. 10 i Strategię 3 p. 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9c0f1c10c8ce825f3a7","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"Metoda dozymetrii indywidualnej"}],"parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"Personal dosimetry method"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction Personal dosimetry method PN-Z-04008-7:2002+Az1:2004","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质 － 呼吸性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"个体剂量测定法"}],"search_zh":"工作环境 − 空气 职业接触评估采样，针对： 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 无机物质 － 呼吸性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 个体剂量测定法 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f3a8","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f3a9","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:","methodology_en":"Concentration of harmful dust agents – inhalable fraction:","parameters":[{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Zakres","range":"(0,10 – 17,80) mg/m3"}],"parameters_en":[{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Range","range":"(0,10 – 17,80) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nZakres (0,10 – 17,80) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nZakres (0,10 – 17,80) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nZakres (0,10 – 17,80) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents – inhalable fraction: Gravimetric method Portland cement Titanium dioxide Natural graphite Synthetic graphite Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Coal (hard, brown) Calcium magnesium carbonate (dolomite) Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","parameters_zh":[{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"范围","range":"(0,10 – 17,80) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 碳酸钙镁（白云石） 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a5dc9c0f1c10c8ce825f3aa","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:","methodology_en":"Concentration of harmful dust agents – respirable fraction:","parameters":[{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 – 15,70) mg/m3"}],"parameters_en":[{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,10 – 15,70) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 15,70) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 15,70) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,10 – 15,70) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents – respirable fraction: Gravimetric method Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","parameters_zh":[{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 – 15,70) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a5dc9c0f1c10c8ce825f3ab","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie gazów:","methodology_en":"Gas concentrations:","parameters":[{"name":"CO","range":"(2,34 – 117,0) mg/m3"},{"name":"Zakres","range":"(2,0 – 100) ppm"}],"parameters_en":[{"name":"CO","range":"(2,34 – 117,0) mg/m3"},{"name":"Range","range":"(2,0 – 100) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie gazów:\nZakres:\nCO (2,34 – 117,0) mg/m3\nZakres (2,0 – 100) ppm\nMetoda elektrochemiczna","reference":"PB-01 wydanie 8 z dnia 14.07.2025 r.","norm_bases":["PB-01 wydanie 8 z dnia 14.07.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie gazów:\nZakres:\nCO (2,34 – 117,0) mg/m3\nZakres (2,0 – 100) ppm\nMetoda elektrochemiczna PB-01 wydanie 8 z dnia 14.07.2025 r. Srodowisko pracy − powietrze Stezenie gazow:\nZakres:\nCO (2,34 – 117,0) mg/m3\nZakres (2,0 – 100) ppm\nMetoda elektrochemiczna PB-01 wydanie 8 z dnia 14.07.2025 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Gas concentrations: Electrochemical method CO Range PB-01 wydanie 8 z dnia 14.07.2025 r.","parameters_zh":[{"name":"CO","range":"(2,34 – 117,0) mg/m3"},{"name":"范围","range":"(2,0 – 100) ppm"}],"search_zh":"工作环境 − 空气 气体浓度： 电化学法 CO 范围 PB-01 wydanie 8 z dnia 14.07.2025 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"气体浓度："},{"_id":"6a5dc9c0f1c10c8ce825f3ac","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PB-01 wydanie 8 z dnia 14.07.2025 r.","norm_bases":["PB-01 wydanie 8 z dnia 14.07.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PB-01 wydanie 8 z dnia 14.07.2025 r. Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PB-01 wydanie 8 z dnia 14.07.2025 r.","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure index (calculated) PB-01 wydanie 8 z dnia 14.07.2025 r.","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PB-01 wydanie 8 z dnia 14.07.2025 r.","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f3ad","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","test_object_en":"Workplace environment − hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) °C"}],"parameters_en":[{"name":"Range","range":"(10 – 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) °C"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f3ae","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","test_object_en":"Workplace environment − hot microclimate","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","methodology_en":"WBGT index, WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f3af","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","test_object_en":"Workplace environment − moderate microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 2,5) m/s"}],"parameters_en":[{"name":"Range","range":"(10 – 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 2,5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 2,5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 2,5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nWilgotnosc powietrza\nZakres (25 – 75) %\nPredkosc powietrza\nZakres (0,15 – 2,5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 2,5) m/s"}],"search_zh":"工作场所环境 − 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a5dc9c0f1c10c8ce825f3b0","lab_id":"69ad52a3de79e566650fb464","country":"PL","accr_number":"AB 871","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","test_object_en":"Workplace environment − moderate microclimate","methodology":"Wskaźnik PMV, Wskaźnik PMD (z obliczeń)","methodology_en":"PMV index, PMD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV, Wskaźnik PMD (z obliczeń)","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PMD (z obliczeń) PN-EN ISO 7730:2006 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PMD (z obliczen) PN-EN ISO 7730:2006","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − moderate microclimate PMV index, PMD index (calculated) PN-EN ISO 7730:2006","search_zh":"工作场所环境 − 中等微气候 PN-EN ISO 7730:2006","test_object_zh":"工作场所环境 − 中等微气候"}],"has_pdf":true}