{"lab":{"_id":"69ad52a3de79e566650fb460","accr_number":"AB 869","country":"PL","accr_body":"PCA","address":"Laboratorium, ul. Południowa 5, 62-006 Kobylnica","categories":["environment","water","petro","materials"],"city":"Kobylnica","imported_at":"2026-03-08T10:42:43.265Z","methods_count":297,"name":"EKOLAB Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_869.pdf"],"scope_summary":"","search_text":"ekolab sp. z o.o. laboratorium, ul. południowa 5, 62-006 kobylnica other water microbiology pharma electronics metrology environment food petro materials automotive construction","status":"active","updated_at":"2026-03-08T14:51:45.515Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T02:01:24.145Z","email_confidence":"high","email_mx":true,"email_source":"https://www.ekolab.pl/kontakt/","fields_of_testing":[],"issue":{"no":"30","date":"16.06.2026"},"parse_date":"2026-08-18T02:01:24.145Z","parse_source":"agent-claude-code","map_coord":[52.445291,17.091008],"map_geo":"nominatim-street","lab_locations":[{"name":"Pracownia Pobierania Próbek i Badań Terenowych","address":"ul. Południowa 5, 62-006 Kobylnica","city":"Kobylnica","postal":"62-006"},{"name":"Pracownia Laboratorium Analitycznego","address":"ul. Południowa 5, 62-006 Kobylnica","city":"Kobylnica","postal":"62-006"},{"name":"Pracownia Pomiarów Środowiska Pracy","address":"ul. Południowa 5, 62-006 Kobylnica","city":"Kobylnica","postal":"62-006"},{"name":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","address":"ul. Południowa 5, 62-006 Kobylnica","city":"Kobylnica","postal":"62-006"},{"name":"Pracownia Pomiarów Emisji Zanieczyszczeń","address":"ul. Południowa 5, 62-006 Kobylnica","city":"Kobylnica","postal":"62-006"},{"name":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","address":null,"city":null,"postal":null},{"name":"Pracownia Laboratorium Analitycznego","address":null,"city":null,"postal":null},{"name":"Pracownia Pobierania Próbek i Badań Terenowych","address":null,"city":null,"postal":null},{"name":"Pracownia Pomiarów Emisji Zanieczyszczeń","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/cb191c99e1208d9c293f771f6b878c41/AB%20869.pdf","has_en":true,"category_counts":{"environment":194,"water":81,"other":28,"petro":20,"materials":10,"metrology":4,"construction":4,"microbiology":1,"automotive":1},"category_scores":{"environment":109.73,"water":19.13,"other":2.29,"petro":1.17,"materials":0.29,"metrology":0.05,"construction":0.05,"microbiology":0,"automotive":0},"has_zh":true},"methods":[{"_id":"6a83bcf4af14b9c0e7b212fa","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(1,0 - 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 - 50,0) °C","reference":"PN-ISO 5667-5:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","norm_bases":["PN-ISO 5667-5:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r."],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 - 50,0) °C PN-ISO 5667-5:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r. Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (1,0 - 50,0) °C PN-ISO 5667-5:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(1,0 - 50,0) °C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-5:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,0 - 50,0) °C"}],"search_zh":"生活饮用水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-5:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a83bcf4af14b9c0e7b212fb","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(1,0 - 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 - 50,0) °C","reference":"PN-ISO 5667-6:2016-12 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","norm_bases":["PN-ISO 5667-6:2016-12 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r."],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 - 50,0) °C PN-ISO 5667-6:2016-12 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r. Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (1,0 - 50,0) °C PN-ISO 5667-6:2016-12 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(1,0 - 50,0) °C"}],"search_en":"Surface water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-6:2016-12 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","test_object_en":"Surface water","parameters_zh":[{"name":"范围","range":"(1,0 - 50,0) °C"}],"search_zh":"地表水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-6:2016-12 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地表水"},{"_id":"6a83bcf4af14b9c0e7b212fc","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda podziemna","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(1,0 - 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 - 50,0) °C","reference":"PN-ISO 5667-11:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","norm_bases":["PN-ISO 5667-11:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r."],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 - 50,0) °C PN-ISO 5667-11:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r. Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (1,0 - 50,0) °C PN-ISO 5667-11:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(1,0 - 50,0) °C"}],"search_en":"Groundwater Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-11:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","test_object_en":"Groundwater","parameters_zh":[{"name":"范围","range":"(1,0 - 50,0) °C"}],"search_zh":"地下水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-11:2017-10 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地下水"},{"_id":"6a83bcf4af14b9c0e7b212fd","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water, Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b212fe","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,10 - 2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,10 - 2,50) mg/l\nMetoda spektrofotometryczna","reference":"EKOLAB/PP/PB-07 wydanie 3 z dnia 02.09.2024 r. wg testu Hanna instruments nr HI701-25","norm_bases":["EKOLAB/PP/PB-07 wydanie 3 z dnia 02.09.2024 r. wg testu Hanna instruments nr HI701-25"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,10 - 2,50) mg/l\nMetoda spektrofotometryczna EKOLAB/PP/PB-07 wydanie 3 z dnia 02.09.2024 r. wg testu Hanna instruments nr HI701-25 Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,10 - 2,50) mg/l\nMetoda spektrofotometryczna EKOLAB/PP/PB-07 wydanie 3 z dnia 02.09.2024 r. wg testu Hanna instruments nr HI701-25","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 - 2,50) mg/l"}],"search_en":"Water, Water intended for human consumption Free chlorine concentration Spectrophotometric method Range EKOLAB/PP/PB-07 wydanie 3 z dnia 02.09.2024 r. wg testu Hanna instruments nr HI701-25","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 2,50) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 分光光度法 范围 EKOLAB/PP/PB-07 wydanie 3 z dnia 02.09.2024 r. wg testu Hanna instruments nr HI701-25","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b212ff","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,10 - 2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,10 - 2,50) mg/l\nMetoda spektrofotometryczna","reference":"EKOLAB/PP/PB-208 wydanie 2 z dnia 02.09.2024 r. wg testu MERCK nr 1.00598.0002","norm_bases":["EKOLAB/PP/PB-208 wydanie 2 z dnia 02.09.2024 r. wg testu MERCK nr 1.00598.0002"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,10 - 2,50) mg/l\nMetoda spektrofotometryczna EKOLAB/PP/PB-208 wydanie 2 z dnia 02.09.2024 r. wg testu MERCK nr 1.00598.0002 Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,10 - 2,50) mg/l\nMetoda spektrofotometryczna EKOLAB/PP/PB-208 wydanie 2 z dnia 02.09.2024 r. wg testu MERCK nr 1.00598.0002","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 - 2,50) mg/l"}],"search_en":"Water, Water intended for human consumption Free chlorine concentration Spectrophotometric method Range EKOLAB/PP/PB-208 wydanie 2 z dnia 02.09.2024 r. wg testu MERCK nr 1.00598.0002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 2,50) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 分光光度法 范围 EKOLAB/PP/PB-208 wydanie 2 z dnia 02.09.2024 r. wg testu MERCK nr 1.00598.0002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21300","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21301","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"100 μS/cm - 6000 μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 100 μS/cm - 6000 μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres 100 μS/cm - 6000 μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres 100 μS/cm - 6000 μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"100 μS/cm - 6000 μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"100 μS/cm - 6000 μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21302","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 - 15) mg/l O2"},{"name":"Procent nasycenia tlenem"},{"name":"Zakres","range":"(5 - 150) % O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 - 15) mg/l O2\nProcent nasycenia tlenem\nZakres (5 - 150) % O2\nMetoda elektrochemiczna","reference":"PN-ENPISO 5814:2013-04","norm_bases":["PN-ENPISO 5814:2013-04"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 - 15) mg/l O2\nProcent nasycenia tlenem\nZakres (5 - 150) % O2\nMetoda elektrochemiczna PN-ENPISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 - 15) mg/l O2\nProcent nasycenia tlenem\nZakres (5 - 150) % O2\nMetoda elektrochemiczna PN-ENPISO 5814:2013-04","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 - 15) mg/l O2"},{"name":"Oxygen saturation percentage"},{"name":"Range","range":"(5 - 150) % O2"}],"search_en":"Water Dissolved oxygen concentration Electrochemical method Range Oxygen saturation percentage Range PN-ENPISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 - 15) mg/l O2"},{"name":"Procent nasycenia tlenem"},{"name":"范围","range":"(5 - 150) % O2"}],"search_zh":"水 溶解氧浓度 电化学法 范围 范围 PN-ENPISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a83bcf4af14b9c0e7b21303","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda","methodology":"Poziom lustra wody (Poziom statyczny i dynamiczny)","parameters":[{"name":"Zakres","range":"(0,10 - 60,00) m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom lustra wody (Poziom statyczny i dynamiczny)\nZakres (0,10 - 60,00) m\nMetoda pomiarowa bezpośrednia","reference":"EKOLAB/PP/PB-196 wydanie 3 z dnia 02.09.2024 r.","norm_bases":["EKOLAB/PP/PB-196 wydanie 3 z dnia 02.09.2024 r."],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda Poziom lustra wody (Poziom statyczny i dynamiczny)\nZakres (0,10 - 60,00) m\nMetoda pomiarowa bezpośrednia EKOLAB/PP/PB-196 wydanie 3 z dnia 02.09.2024 r. Woda Poziom lustra wody (Poziom statyczny i dynamiczny)\nZakres (0,10 - 60,00) m\nMetoda pomiarowa bezposrednia EKOLAB/PP/PB-196 wydanie 3 z dnia 02.09.2024 r.","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water table level (static and dynamic level)","parameters_en":[{"name":"Range","range":"(0,10 - 60,00) m"}],"search_en":"Water Water table level (static and dynamic level) Direct measurement method Range EKOLAB/PP/PB-196 wydanie 3 z dnia 02.09.2024 r.","technique_en":"Direct measurement method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,10 - 60,00) m"}],"search_zh":"水 直接测量法 范围 EKOLAB/PP/PB-196 wydanie 3 z dnia 02.09.2024 r.","technique_zh":"直接测量法","test_object_zh":"水"},{"_id":"6a83bcf4af14b9c0e7b21304","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Ścieki, Wody opadowe, wody roztopowe","methodology":"Pobieranie próbek","parameters":[{"name":"Temperatura ścieku / pobranej próbki ścieku"},{"name":"Zakres","range":"(1,0 - 50,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek\nZakres:\nTemperatura ścieku / pobranej próbki ścieku\nZakres (1,0 - 50,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN ISO 5667-10:2021-11 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","norm_bases":["PN ISO 5667-10:2021-11 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r."],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki, Wody opadowe, wody roztopowe Pobieranie próbek\nZakres:\nTemperatura ścieku / pobranej próbki ścieku\nZakres (1,0 - 50,0) °C\nMetoda manualna; Metoda automatyczna PN ISO 5667-10:2021-11 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r. Scieki, Wody opadowe, wody roztopowe Pobieranie probek\nZakres:\nTemperatura scieku / pobranej probki scieku\nZakres (1,0 - 50,0) °C\nMetoda manualna; Metoda automatyczna PN ISO 5667-10:2021-11 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","parameters_en":[{"name":"Temperature of wastewater / of the collected wastewater sample"},{"name":"Range","range":"(1,0 - 50,0) °C"}],"search_en":"Wastewater, Rainwater, snowmelt water Sampling Manual method; Automatic method Temperature of wastewater / of the collected wastewater sample Range PN ISO 5667-10:2021-11 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater, Rainwater, snowmelt water","methodology_zh":"样品采集","parameters_zh":[{"name":"Temperatura ścieku / pobranej próbki ścieku"},{"name":"范围","range":"(1,0 - 50,0) °C"}],"search_zh":"样品采集 手动法；自动法 范围 PN ISO 5667-10:2021-11 EKOLAB/PP/PB-60 wydanie 3 z dnia 02.09.2024 r.","technique_zh":"手动法；自动法"},{"_id":"6a83bcf4af14b9c0e7b21305","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a83bcf4af14b9c0e7b21306","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011","test_object_zh":"污泥"},{"_id":"6a83bcf4af14b9c0e7b21307","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997 | PN-ISO 10381-5:2009","norm_bases":["PN-R-04031:1997","PN-ISO 10381-5:2009"],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-R-04031:1997 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a83bcf4af14b9c0e7b21308","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 19 12 10, 02 02 04, 03 03 07, 04 02 09, 04 02 22, 07 02 13, 10 01 01, 10 02 02, 12 01 05, 15 02 03, 16 03 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 12, 19 03 05, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 12 09, 19 12 10, 19 12 12, 20 01 99, 20 02 01, 20 02 03, 20 03 02, 20 03 03, 20 03 99","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"EKOLAB/LB/PB-193 wydanie 2 z dnia 15.04.2014 r.","norm_bases":["EKOLAB/LB/PB-193 wydanie 2 z dnia 15.04.2014 r."],"lab_section":"Pracownia Pobierania Próbek i Badań Terenowych","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium; O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 12 10, 02 02 04, 03 03 07, 04 02 09, 04 02 22, 07 02 13, 10 01 01, 10 02 02, 12 01 05, 15 02 03, 16 03 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 12, 19 03 05, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 12 09, 19 12 10, 19 12 12, 20 01 99, 20 02 01, 20 02 03, 20 03 02, 20 03 03, 20 03 99 Pobieranie próbek do badań chemicznych i fizycznych EKOLAB/LB/PB-193 wydanie 2 z dnia 15.04.2014 r. Odpady O) kod: 19 12 10, 02 02 04, 03 03 07, 04 02 09, 04 02 22, 07 02 13, 10 01 01, 10 02 02, 12 01 05, 15 02 03, 16 03 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 12, 19 03 05, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 14, 19 12 09, 19 12 10, 19 12 12, 20 01 99, 20 02 01, 20 02 03, 20 03 02, 20 03 03, 20 03 99 Pobieranie probek do badan chemicznych i fizycznych EKOLAB/LB/PB-193 wydanie 2 z dnia 15.04.2014 r.","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing EKOLAB/LB/PB-193 wydanie 2 z dnia 15.04.2014 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 EKOLAB/LB/PB-193 wydanie 2 z dnia 15.04.2014 r."},{"_id":"6a83bcf4af14b9c0e7b21309","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,005 - 0,05) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,005 - 0,05) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chromu (VI)\nZakres (0,005 - 0,05) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda Stezenie chromu (VI)\nZakres (0,005 - 0,05) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,005 - 0,05) mg/l"}],"search_en":"Water Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,005 - 0,05) mg/l"}],"search_zh":"水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"六价铬浓度"},{"_id":"6a83bcf4af14b9c0e7b2130a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 200) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 200) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027 -1:2016-09","norm_bases":["PN-EN ISO 7027 -1:2016-09"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 - 200) NTU\nMetoda nefelometryczna PN-EN ISO 7027 -1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 - 200) NTU\nMetoda nefelometryczna PN-EN ISO 7027 -1:2016-09","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 200) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027 -1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 200) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027 -1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2130b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie rozpuszczonych jonów","parameters":[{"name":"azotany","range":"(0,50 - 200) mg/l"},{"name":"azotyny","range":"(0,20 - 20,0) mg/l"},{"name":"chlorki","range":"(0,50 - 500) mg/l"},{"name":"fluorki","range":"(0,10 - 4,0) mg/l"},{"name":"bromki","range":"(0,20 - 20) mg/l"},{"name":"siarczany","range":"(0,50 - 500) mg/l"},{"name":"fosforany","range":"(0,50 - 40) mg/l"}],"technique":"Metoda chromatografii jonowej (IC)","techniques":["Metoda chromatografii jonowej (IC)"],"computed":[],"activity":"Stężenie rozpuszczonych jonów\nZakres:\nazotany (0,50 - 200) mg/l\nazotyny (0,20 - 20,0) mg/l\nchlorki (0,50 - 500) mg/l\nfluorki (0,10 - 4,0) mg/l\nbromki (0,20 - 20) mg/l\nsiarczany (0,50 - 500) mg/l\nfosforany (0,50 - 40) mg/l\nMetoda chromatografii jonowej (IC)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie rozpuszczonych jonów\nZakres:\nazotany (0,50 - 200) mg/l\nazotyny (0,20 - 20,0) mg/l\nchlorki (0,50 - 500) mg/l\nfluorki (0,10 - 4,0) mg/l\nbromki (0,20 - 20) mg/l\nsiarczany (0,50 - 500) mg/l\nfosforany (0,50 - 40) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009 Woda, Woda do spozycia przez ludzi Stezenie rozpuszczonych jonow\nZakres:\nazotany (0,50 - 200) mg/l\nazotyny (0,20 - 20,0) mg/l\nchlorki (0,50 - 500) mg/l\nfluorki (0,10 - 4,0) mg/l\nbromki (0,20 - 20) mg/l\nsiarczany (0,50 - 500) mg/l\nfosforany (0,50 - 40) mg/l\nMetoda chromatografii jonowej (IC) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved ion concentration","parameters_en":[{"name":"nitrates","range":"(0,50 - 200) mg/l"},{"name":"nitrites","range":"(0,20 - 20,0) mg/l"},{"name":"chlorides","range":"(0,50 - 500) mg/l"},{"name":"fluorides","range":"(0,10 - 4,0) mg/l"},{"name":"bromides","range":"(0,20 - 20) mg/l"},{"name":"sulfates","range":"(0,50 - 500) mg/l"},{"name":"phosphates","range":"(0,50 - 40) mg/l"}],"search_en":"Water, Water intended for human consumption Dissolved ion concentration Ion chromatography (IC) nitrates nitrites chlorides fluorides bromides sulfates phosphates PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography (IC)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 溶解性离子浓度 离子色谱法（IC） 硝酸盐 亚硝酸盐 氯化物 氟化物 溴化物 硫酸盐 磷酸盐 PN-EN ISO 10304-1:2009","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"硝酸盐","range":"(0,50 - 200) mg/l"},{"name":"亚硝酸盐","range":"(0,20 - 20,0) mg/l"},{"name":"氯化物","range":"(0,50 - 500) mg/l"},{"name":"氟化物","range":"(0,10 - 4,0) mg/l"},{"name":"溴化物","range":"(0,20 - 20) mg/l"},{"name":"硫酸盐","range":"(0,50 - 500) mg/l"},{"name":"磷酸盐","range":"(0,50 - 40) mg/l"}],"technique_zh":"离子色谱法（IC）","methodology_zh":"溶解性离子浓度"},{"_id":"6a83bcf4af14b9c0e7b2130c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu azotanowego, Stężenie azotu azotynowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego, Stężenie azotu azotynowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotu azotanowego, Stężenie azotu azotynowego (z obliczeń) PN-EN ISO 10304-1:2009 Woda, Woda do spozycia przez ludzi Stezenie azotu azotanowego, Stezenie azotu azotynowego (z obliczen) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration, Nitrite nitrogen concentration (calculated)","search_en":"Water, Water intended for human consumption Nitrate nitrogen concentration, Nitrite nitrogen concentration (calculated) PN-EN ISO 10304-1:2009","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 PN-EN ISO 10304-1:2009","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2130d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0001 - 0,01) mg/l"},{"name":"Zakres","range":"(0,10 - 10,0) μg/l"}],"technique":"Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CV-AFS)","techniques":["Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CV-AFS)"],"computed":[],"activity":"Stężenie rtęci\nZakres:\nZakres (0,0001 - 0,01) mg/l\nZakres (0,10 - 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CV-AFS)","reference":"PN EN ISO 17852:2009","norm_bases":["PN EN ISO 17852:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie rtęci\nZakres:\nZakres (0,0001 - 0,01) mg/l\nZakres (0,10 - 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CV-AFS) PN EN ISO 17852:2009 Woda, Woda do spozycia przez ludzi Stezenie rteci\nZakres:\nZakres (0,0001 - 0,01) mg/l\nZakres (0,10 - 10,0) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CV-AFS) PN EN ISO 17852:2009","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0001 - 0,01) mg/l"},{"name":"Range","range":"(0,10 - 10,0) μg/l"}],"search_en":"Water, Water intended for human consumption Mercury concentration Atomic fluorescence spectrometry with cold vapour generation (CV-AFS) Range Range PN EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry with cold vapour generation (CV-AFS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0001 - 0,01) mg/l"},{"name":"范围","range":"(0,10 - 10,0) μg/l"}],"search_zh":"水、生活饮用水 汞浓度 范围 范围 PN EN ISO 17852:2009","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2130e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie pierwiastków","parameters":[{"name":"Ag","range":"(0,0005 - 0,05) mg/l"},{"name":"Al","range":"(0,002 - 0,5) mg/l"},{"name":"Zakres","range":"(2,0 - 500) μg/l"},{"name":"As","range":"(0,001 - 0,1) mg/l"},{"name":"(1,0 - 100) μg/l"},{"name":"B","range":"(0,01 - 2,0) mg/l"},{"name":"Ba","range":"(0,01 - 0,5) mg/l"},{"name":"Be","range":"(0,0001 - 0,05) mg/l"},{"name":"Cd","range":"(0,0005 - 0,2) mg/l"},{"name":"(0,50 - 200) μg/l"},{"name":"Co","range":"(0,005 - 0,5) mg/l"},{"name":"Cr","range":"(0,002 - 0,5) mg/l"},{"name":"(2,0 - 500) μg/l"},{"name":"Cu","range":"(0,01 - 2,0) mg/l"},{"name":"Mo","range":"(0,001 - 0,5) mg/l"},{"name":"Ni","range":"(0,001 - 0,5) mg/l"},{"name":"(1,0 - 500) μg/l"},{"name":"Pb","range":"(0,0005 - 0,5) mg/l"},{"name":"(0,50 - 500) μg/l"},{"name":"Sb","range":"(0,0005 - 0,5) mg/l"},{"name":"(0,50 - 500) μg/l"},{"name":"Se","range":"(0,001 - 0,01) mg/l"},{"name":"(1,0 - 10,0) μg/l"},{"name":"Sn","range":"(0,005 - 0,1) mg/l"},{"name":"Ti","range":"(0,001 - 0,1) mg/l"},{"name":"Tl","range":"(0,0005 - 0,2) mg/l"},{"name":"V","range":"(0,001 - 0,5) mg/l"},{"name":"Zn","range":"(0,001 - 0,5) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAg (0,0005 - 0,05) mg/l\nAl (0,002 - 0,5) mg/l\nZakres (2,0 - 500) μg/l\nAs (0,001 - 0,1) mg/l\n(1,0 - 100) μg/l\nB (0,01 - 2,0) mg/l\nBa (0,01 - 0,5) mg/l\nBe (0,0001 - 0,05) mg/l\nCd (0,0005 - 0,2) mg/l\n(0,50 - 200) μg/l\nCo (0,005 - 0,5) mg/l\nCr (0,002 - 0,5) mg/l\n(2,0 - 500) μg/l\nCu (0,01 - 2,0) mg/l\nMo (0,001 - 0,5) mg/l\nNi (0,001 - 0,5) mg/l\n(1,0 - 500) μg/l\nPb (0,0005 - 0,5) mg/l\n(0,50 - 500) μg/l\nSb (0,0005 - 0,5) mg/l\n(0,50 - 500) μg/l\nSe (0,001 - 0,01) mg/l\n(1,0 - 10,0) μg/l\nSn (0,005 - 0,1) mg/l\nTi (0,001 - 0,1) mg/l\nTl (0,0005 - 0,2) mg/l\nV (0,001 - 0,5) mg/l\nZn (0,001 - 0,5) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nAg (0,0005 - 0,05) mg/l\nAl (0,002 - 0,5) mg/l\nZakres (2,0 - 500) μg/l\nAs (0,001 - 0,1) mg/l\n(1,0 - 100) μg/l\nB (0,01 - 2,0) mg/l\nBa (0,01 - 0,5) mg/l\nBe (0,0001 - 0,05) mg/l\nCd (0,0005 - 0,2) mg/l\n(0,50 - 200) μg/l\nCo (0,005 - 0,5) mg/l\nCr (0,002 - 0,5) mg/l\n(2,0 - 500) μg/l\nCu (0,01 - 2,0) mg/l\nMo (0,001 - 0,5) mg/l\nNi (0,001 - 0,5) mg/l\n(1,0 - 500) μg/l\nPb (0,0005 - 0,5) mg/l\n(0,50 - 500) μg/l\nSb (0,0005 - 0,5) mg/l\n(0,50 - 500) μg/l\nSe (0,001 - 0,01) mg/l\n(1,0 - 10,0) μg/l\nSn (0,005 - 0,1) mg/l\nTi (0,001 - 0,1) mg/l\nTl (0,0005 - 0,2) mg/l\nV (0,001 - 0,5) mg/l\nZn (0,001 - 0,5) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nAg (0,0005 - 0,05) mg/l\nAl (0,002 - 0,5) mg/l\nZakres (2,0 - 500) μg/l\nAs (0,001 - 0,1) mg/l\n(1,0 - 100) μg/l\nB (0,01 - 2,0) mg/l\nBa (0,01 - 0,5) mg/l\nBe (0,0001 - 0,05) mg/l\nCd (0,0005 - 0,2) mg/l\n(0,50 - 200) μg/l\nCo (0,005 - 0,5) mg/l\nCr (0,002 - 0,5) mg/l\n(2,0 - 500) μg/l\nCu (0,01 - 2,0) mg/l\nMo (0,001 - 0,5) mg/l\nNi (0,001 - 0,5) mg/l\n(1,0 - 500) μg/l\nPb (0,0005 - 0,5) mg/l\n(0,50 - 500) μg/l\nSb (0,0005 - 0,5) mg/l\n(0,50 - 500) μg/l\nSe (0,001 - 0,01) mg/l\n(1,0 - 10,0) μg/l\nSn (0,005 - 0,1) mg/l\nTi (0,001 - 0,1) mg/l\nTl (0,0005 - 0,2) mg/l\nV (0,001 - 0,5) mg/l\nZn (0,001 - 0,5) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Ag","range":"(0,0005 - 0,05) mg/l"},{"name":"Al","range":"(0,002 - 0,5) mg/l"},{"name":"Range","range":"(2,0 - 500) μg/l"},{"name":"As","range":"(0,001 - 0,1) mg/l"},{"name":"(1,0 - 100) μg/l"},{"name":"B","range":"(0,01 - 2,0) mg/l"},{"name":"Ba","range":"(0,01 - 0,5) mg/l"},{"name":"Be","range":"(0,0001 - 0,05) mg/l"},{"name":"Cd","range":"(0,0005 - 0,2) mg/l"},{"name":"(0,50 - 200) μg/l"},{"name":"Co","range":"(0,005 - 0,5) mg/l"},{"name":"Cr","range":"(0,002 - 0,5) mg/l"},{"name":"(2,0 - 500) μg/l"},{"name":"Cu","range":"(0,01 - 2,0) mg/l"},{"name":"Mo","range":"(0,001 - 0,5) mg/l"},{"name":"Ni","range":"(0,001 - 0,5) mg/l"},{"name":"(1,0 - 500) μg/l"},{"name":"Pb","range":"(0,0005 - 0,5) mg/l"},{"name":"(0,50 - 500) μg/l"},{"name":"Sb","range":"(0,0005 - 0,5) mg/l"},{"name":"(0,50 - 500) μg/l"},{"name":"Se","range":"(0,001 - 0,01) mg/l"},{"name":"(1,0 - 10,0) μg/l"},{"name":"Sn","range":"(0,005 - 0,1) mg/l"},{"name":"Ti","range":"(0,001 - 0,1) mg/l"},{"name":"Tl","range":"(0,0005 - 0,2) mg/l"},{"name":"V","range":"(0,001 - 0,5) mg/l"},{"name":"Zn","range":"(0,001 - 0,5) mg/l"}],"search_en":"Water, Water intended for human consumption Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Ag Al Range As (1,0 - 100) μg/l B Ba Be Cd (0,50 - 200) μg/l Co Cr (2,0 - 500) μg/l Cu Mo Ni (1,0 - 500) μg/l Pb (0,50 - 500) μg/l Sb (0,50 - 500) μg/l Se (1,0 - 10,0) μg/l Sn Ti Tl V Zn PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"元素浓度","parameters_zh":[{"name":"Ag","range":"(0,0005 - 0,05) mg/l"},{"name":"Al","range":"(0,002 - 0,5) mg/l"},{"name":"范围","range":"(2,0 - 500) μg/l"},{"name":"As","range":"(0,001 - 0,1) mg/l"},{"name":"(1,0 - 100) μg/l"},{"name":"B","range":"(0,01 - 2,0) mg/l"},{"name":"Ba","range":"(0,01 - 0,5) mg/l"},{"name":"Be","range":"(0,0001 - 0,05) mg/l"},{"name":"Cd","range":"(0,0005 - 0,2) mg/l"},{"name":"(0,50 - 200) μg/l"},{"name":"Co","range":"(0,005 - 0,5) mg/l"},{"name":"Cr","range":"(0,002 - 0,5) mg/l"},{"name":"(2,0 - 500) μg/l"},{"name":"Cu","range":"(0,01 - 2,0) mg/l"},{"name":"Mo","range":"(0,001 - 0,5) mg/l"},{"name":"Ni","range":"(0,001 - 0,5) mg/l"},{"name":"(1,0 - 500) μg/l"},{"name":"Pb","range":"(0,0005 - 0,5) mg/l"},{"name":"(0,50 - 500) μg/l"},{"name":"Sb","range":"(0,0005 - 0,5) mg/l"},{"name":"(0,50 - 500) μg/l"},{"name":"Se","range":"(0,001 - 0,01) mg/l"},{"name":"(1,0 - 10,0) μg/l"},{"name":"Sn","range":"(0,005 - 0,1) mg/l"},{"name":"Ti","range":"(0,001 - 0,1) mg/l"},{"name":"Tl","range":"(0,0005 - 0,2) mg/l"},{"name":"V","range":"(0,001 - 0,5) mg/l"},{"name":"Zn","range":"(0,001 - 0,5) mg/l"}],"search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体质谱法（ICP-MS） Ag Al 范围 As B Ba Be Cd Co Cr Cu Mo Ni Pb Sb Se Sn Ti Tl V Zn PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2130f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie pierwiastków","parameters":[{"name":"Fe","range":"(0,050 - 30) mg/l"},{"name":"Zakres","range":"(50 - 30000) μg/l"},{"name":"Na","range":"(5 - 2000) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"(10 - 10000) μg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nFe (0,050 - 30) mg/l\nZakres (50 - 30000) μg/l\nNa (5 - 2000) mg/l\nMn (0,010 - 10) mg/l\n(10 - 10000) μg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nFe (0,050 - 30) mg/l\nZakres (50 - 30000) μg/l\nNa (5 - 2000) mg/l\nMn (0,010 - 10) mg/l\n(10 - 10000) μg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nFe (0,050 - 30) mg/l\nZakres (50 - 30000) μg/l\nNa (5 - 2000) mg/l\nMn (0,010 - 10) mg/l\n(10 - 10000) μg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Fe","range":"(0,050 - 30) mg/l"},{"name":"Range","range":"(50 - 30000) μg/l"},{"name":"Na","range":"(5 - 2000) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"(10 - 10000) μg/l"}],"search_en":"Water, Water intended for human consumption Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Fe Range Na Mn (10 - 10000) μg/l PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"元素浓度","parameters_zh":[{"name":"Fe","range":"(0,050 - 30) mg/l"},{"name":"范围","range":"(50 - 30000) μg/l"},{"name":"Na","range":"(5 - 2000) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"(10 - 10000) μg/l"}],"search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Fe 范围 Na Mn PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21310","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"As","range":"(0,0020 - 0,50) mg/l"},{"name":"Cd","range":"(0,0020 - 0,50) mg/l"},{"name":"Cr","range":"(0,0020 - 0,50) mg/l"},{"name":"Cu","range":"(0,0020 - 0,50) mg/l"},{"name":"Ni","range":"(0,0020 - 0,50) mg/l"},{"name":"Pb","range":"(0,0020 - 0,50) mg/l"},{"name":"Tl","range":"(0,0020 - 0,50) mg/l"},{"name":"Zn","range":"(0,0020 - 0,50) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAs (0,0020 - 0,50) mg/l\nCd (0,0020 - 0,50) mg/l\nCr (0,0020 - 0,50) mg/l\nCu (0,0020 - 0,50) mg/l\nNi (0,0020 - 0,50) mg/l\nPb (0,0020 - 0,50) mg/l\nTl (0,0020 - 0,50) mg/l\nZn (0,0020 - 0,50) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nAs (0,0020 - 0,50) mg/l\nCd (0,0020 - 0,50) mg/l\nCr (0,0020 - 0,50) mg/l\nCu (0,0020 - 0,50) mg/l\nNi (0,0020 - 0,50) mg/l\nPb (0,0020 - 0,50) mg/l\nTl (0,0020 - 0,50) mg/l\nZn (0,0020 - 0,50) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Scieki Stezenie pierwiastkow\nZakres:\nAs (0,0020 - 0,50) mg/l\nCd (0,0020 - 0,50) mg/l\nCr (0,0020 - 0,50) mg/l\nCu (0,0020 - 0,50) mg/l\nNi (0,0020 - 0,50) mg/l\nPb (0,0020 - 0,50) mg/l\nTl (0,0020 - 0,50) mg/l\nZn (0,0020 - 0,50) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"As","range":"(0,0020 - 0,50) mg/l"},{"name":"Cd","range":"(0,0020 - 0,50) mg/l"},{"name":"Cr","range":"(0,0020 - 0,50) mg/l"},{"name":"Cu","range":"(0,0020 - 0,50) mg/l"},{"name":"Ni","range":"(0,0020 - 0,50) mg/l"},{"name":"Pb","range":"(0,0020 - 0,50) mg/l"},{"name":"Tl","range":"(0,0020 - 0,50) mg/l"},{"name":"Zn","range":"(0,0020 - 0,50) mg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) As Cd Cr Cu Ni Pb Tl Zn PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"As","range":"(0,0020 - 0,50) mg/l"},{"name":"Cd","range":"(0,0020 - 0,50) mg/l"},{"name":"Cr","range":"(0,0020 - 0,50) mg/l"},{"name":"Cu","range":"(0,0020 - 0,50) mg/l"},{"name":"Ni","range":"(0,0020 - 0,50) mg/l"},{"name":"Pb","range":"(0,0020 - 0,50) mg/l"},{"name":"Tl","range":"(0,0020 - 0,50) mg/l"},{"name":"Zn","range":"(0,0020 - 0,50) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体质谱法（ICP-MS） As Cd Cr Cu Ni Pb Tl Zn PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"污水"},{"_id":"6a83bcf4af14b9c0e7b21311","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,001 - 0,50) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,001 - 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07E","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07E"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,001 - 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07E Woda, scieki Stezenie rteci\nZakres (0,001 - 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07E","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,001 - 0,50) mg/l"}],"search_en":"Water, wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 +Ap1:2016-07E","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 0,50) mg/l"}],"search_zh":"水、废水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 +Ap1:2016-07E","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21312","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,5 - 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,5 - 250) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów\nZakres (0,5 - 250) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotanow\nZakres (0,5 - 250) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,5 - 250) mg/l"}],"search_en":"Water, wastewater Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,5 - 250) mg/l"}],"search_zh":"水、废水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21313","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-82/C-04576/08","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PN-82/C-04576/08","test_object_en":"Water, wastewater","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PN-82/C-04576/08","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a83bcf4af14b9c0e7b21314","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie talu","parameters":[{"name":"Zakres","range":"(0,8 - 10) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie talu\nZakres (0,8 - 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"IR-01 wydanie nr 1 z dnia 06.01.2011 r.","norm_bases":["IR-01 wydanie nr 1 z dnia 06.01.2011 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie talu\nZakres (0,8 - 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) IR-01 wydanie nr 1 z dnia 06.01.2011 r. Woda, scieki Stezenie talu\nZakres (0,8 - 10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) IR-01 wydanie nr 1 z dnia 06.01.2011 r.","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thallium concentration","parameters_en":[{"name":"Range","range":"(0,8 - 10) mg/l"}],"search_en":"Water, wastewater Thallium concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range IR-01 wydanie nr 1 z dnia 06.01.2011 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,8 - 10) mg/l"}],"search_zh":"水、废水 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 IR-01 wydanie nr 1 z dnia 06.01.2011 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21315","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 - 150) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 - 150) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (0,50 - 150) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-05 Woda, scieki Stezenie azotu ogolnego\nZakres (0,50 - 150) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 - 150) mg/l"}],"search_en":"Water, wastewater Total nitrogen concentration High-temperature combustion with chemiluminescence detection Range PN-EN ISO 20236:2025-05","technique_en":"High-temperature combustion with chemiluminescence detection","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 - 150) mg/l"}],"search_zh":"水、废水 总氮浓度 高温燃烧-化学发光检测法 范围 PN-EN ISO 20236:2025-05","test_object_zh":"水、废水","technique_zh":"高温燃烧-化学发光检测法"},{"_id":"6a83bcf4af14b9c0e7b21316","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie detergentów anionowych","parameters":[{"name":"Zakres","range":"(0,05 - 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów anionowych\nZakres (0,05 - 20) mg/l\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-22 wydanie 4 z dnia 25.08.2015 r. wg testu MERCK nr 1.02552.0001","norm_bases":["EKOLAB/LB/PB-22 wydanie 4 z dnia 25.08.2015 r. wg testu MERCK nr 1.02552.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie detergentów anionowych\nZakres (0,05 - 20) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-22 wydanie 4 z dnia 25.08.2015 r. wg testu MERCK nr 1.02552.0001 Woda, scieki Stezenie detergentow anionowych\nZakres (0,05 - 20) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-22 wydanie 4 z dnia 25.08.2015 r. wg testu MERCK nr 1.02552.0001","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic detergent concentration","parameters_en":[{"name":"Range","range":"(0,05 - 20) mg/l"}],"search_en":"Water, wastewater Anionic detergent concentration Spectrophotometric method Range EKOLAB/LB/PB-22 wydanie 4 z dnia 25.08.2015 r. wg testu MERCK nr 1.02552.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,05 - 20) mg/l"}],"search_zh":"水、废水 阴离子洗涤剂浓度 分光光度法 范围 EKOLAB/LB/PB-22 wydanie 4 z dnia 25.08.2015 r. wg testu MERCK nr 1.02552.0001","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"阴离子洗涤剂浓度"},{"_id":"6a83bcf4af14b9c0e7b21317","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie detergentów niejonowych","parameters":[{"name":"Zakres","range":"(0,10 - 75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów niejonowych\nZakres (0,10 - 75) mg/l\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-23 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.01787.0001","norm_bases":["EKOLAB/LB/PB-23 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.01787.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie detergentów niejonowych\nZakres (0,10 - 75) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-23 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.01787.0001 Woda, scieki Stezenie detergentow niejonowych\nZakres (0,10 - 75) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-23 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.01787.0001","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Non-ionic detergent concentration","parameters_en":[{"name":"Range","range":"(0,10 - 75) mg/l"}],"search_en":"Water, wastewater Non-ionic detergent concentration Spectrophotometric method Range EKOLAB/LB/PB-23 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.01787.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 75) mg/l"}],"search_zh":"水、废水 分光光度法 范围 EKOLAB/LB/PB-23 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.01787.0001","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21318","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,6 - 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,6 - 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,6 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,6 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,6 - 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,6 - 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21319","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3,0 - 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna badane cechy/metoda","techniques":["Metoda elektrochemiczna badane cechy/metoda"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 - 6000) mg/l O2\nMetoda elektrochemiczna badane cechy/metoda","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 - 6000) mg/l O2\nMetoda elektrochemiczna badane cechy/metoda PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 - 6000) mg/l O2\nMetoda elektrochemiczna badane cechy/metoda PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3,0 - 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method tested characteristics/method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method tested characteristics/method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3,0 - 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b2131a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"Ag","range":"(0,1 - 5) mg/l"},{"name":"As","range":"(0,02 - 5) mg/l"},{"name":"B","range":"(0,1 - 10) mg/l"},{"name":"Be","range":"(0,01 - 1,0) mg/l"},{"name":"Ba","range":"(0,01 - 5,0) mg/l"},{"name":"Ca","range":"(1 - 500) mg/l"},{"name":"Cd","range":"(0,01 - 5) mg/l"},{"name":"Co","range":"(0,04 - 10) mg/l"},{"name":"Cr","range":"(0,04 - 10) mg/l"},{"name":"Cu","range":"(0,05 - 5) mg/l"},{"name":"Fe","range":"(0,1 - 30) mg/l"},{"name":"K","range":"(5 - 200) mg/l"},{"name":"Mg","range":"(1 - 100) mg/l"},{"name":"Mn","range":"(0,02 - 10) mg/l"},{"name":"Mo","range":"(0,1 - 10) mg/l"},{"name":"Na","range":"(5 - 2000) mg/l"},{"name":"Ni","range":"(0,04 - 10) mg/l"},{"name":"Pb","range":"(0,3 - 10) mg/l"},{"name":"Sb","range":"(0,2 - 10) mg/l"},{"name":"Se","range":"(0,6 - 10) mg/l"},{"name":"Sn","range":"(0,3 - 2) mg/l"},{"name":"Sr","range":"(0,02 - 2) mg/l"},{"name":"Ti","range":"(0,05 - 2) mg/l"},{"name":"V","range":"(0,2 - 2) mg/l"},{"name":"Zn","range":"(0,05 - 50) mg/l"},{"name":"Al","range":"(0,3 - 10) mg/l"},{"name":"P","range":"(0,3 - 1000) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAg (0,1 - 5) mg/l\nAs (0,02 - 5) mg/l\nB (0,1 - 10) mg/l\nBe (0,01 - 1,0) mg/l\nBa (0,01 - 5,0) mg/l\nCa (1 - 500) mg/l\nCd (0,01 - 5) mg/l\nCo (0,04 - 10) mg/l\nCr (0,04 - 10) mg/l\nCu (0,05 - 5) mg/l\nFe (0,1 - 30) mg/l\nK (5 - 200) mg/l\nMg (1 - 100) mg/l\nMn (0,02 - 10) mg/l\nMo (0,1 - 10) mg/l\nNa (5 - 2000) mg/l\nNi (0,04 - 10) mg/l\nPb (0,3 - 10) mg/l\nSb (0,2 - 10) mg/l\nSe (0,6 - 10) mg/l\nSn (0,3 - 2) mg/l\nSr (0,02 - 2) mg/l\nTi (0,05 - 2) mg/l\nV (0,2 - 2) mg/l\nZn (0,05 - 50) mg/l\nAl (0,3 - 10) mg/l\nP (0,3 - 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nAg (0,1 - 5) mg/l\nAs (0,02 - 5) mg/l\nB (0,1 - 10) mg/l\nBe (0,01 - 1,0) mg/l\nBa (0,01 - 5,0) mg/l\nCa (1 - 500) mg/l\nCd (0,01 - 5) mg/l\nCo (0,04 - 10) mg/l\nCr (0,04 - 10) mg/l\nCu (0,05 - 5) mg/l\nFe (0,1 - 30) mg/l\nK (5 - 200) mg/l\nMg (1 - 100) mg/l\nMn (0,02 - 10) mg/l\nMo (0,1 - 10) mg/l\nNa (5 - 2000) mg/l\nNi (0,04 - 10) mg/l\nPb (0,3 - 10) mg/l\nSb (0,2 - 10) mg/l\nSe (0,6 - 10) mg/l\nSn (0,3 - 2) mg/l\nSr (0,02 - 2) mg/l\nTi (0,05 - 2) mg/l\nV (0,2 - 2) mg/l\nZn (0,05 - 50) mg/l\nAl (0,3 - 10) mg/l\nP (0,3 - 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\nAg (0,1 - 5) mg/l\nAs (0,02 - 5) mg/l\nB (0,1 - 10) mg/l\nBe (0,01 - 1,0) mg/l\nBa (0,01 - 5,0) mg/l\nCa (1 - 500) mg/l\nCd (0,01 - 5) mg/l\nCo (0,04 - 10) mg/l\nCr (0,04 - 10) mg/l\nCu (0,05 - 5) mg/l\nFe (0,1 - 30) mg/l\nK (5 - 200) mg/l\nMg (1 - 100) mg/l\nMn (0,02 - 10) mg/l\nMo (0,1 - 10) mg/l\nNa (5 - 2000) mg/l\nNi (0,04 - 10) mg/l\nPb (0,3 - 10) mg/l\nSb (0,2 - 10) mg/l\nSe (0,6 - 10) mg/l\nSn (0,3 - 2) mg/l\nSr (0,02 - 2) mg/l\nTi (0,05 - 2) mg/l\nV (0,2 - 2) mg/l\nZn (0,05 - 50) mg/l\nAl (0,3 - 10) mg/l\nP (0,3 - 1000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Ag","range":"(0,1 - 5) mg/l"},{"name":"As","range":"(0,02 - 5) mg/l"},{"name":"B","range":"(0,1 - 10) mg/l"},{"name":"Be","range":"(0,01 - 1,0) mg/l"},{"name":"Ba","range":"(0,01 - 5,0) mg/l"},{"name":"Ca","range":"(1 - 500) mg/l"},{"name":"Cd","range":"(0,01 - 5) mg/l"},{"name":"Co","range":"(0,04 - 10) mg/l"},{"name":"Cr","range":"(0,04 - 10) mg/l"},{"name":"Cu","range":"(0,05 - 5) mg/l"},{"name":"Fe","range":"(0,1 - 30) mg/l"},{"name":"K","range":"(5 - 200) mg/l"},{"name":"Mg","range":"(1 - 100) mg/l"},{"name":"Mn","range":"(0,02 - 10) mg/l"},{"name":"Mo","range":"(0,1 - 10) mg/l"},{"name":"Na","range":"(5 - 2000) mg/l"},{"name":"Ni","range":"(0,04 - 10) mg/l"},{"name":"Pb","range":"(0,3 - 10) mg/l"},{"name":"Sb","range":"(0,2 - 10) mg/l"},{"name":"Se","range":"(0,6 - 10) mg/l"},{"name":"Sn","range":"(0,3 - 2) mg/l"},{"name":"Sr","range":"(0,02 - 2) mg/l"},{"name":"Ti","range":"(0,05 - 2) mg/l"},{"name":"V","range":"(0,2 - 2) mg/l"},{"name":"Zn","range":"(0,05 - 50) mg/l"},{"name":"Al","range":"(0,3 - 10) mg/l"},{"name":"P","range":"(0,3 - 1000) mg/l"}],"search_en":"Water, wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Ag As B Be Ba Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Sn Sr Ti V Zn Al P PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"Ag","range":"(0,1 - 5) mg/l"},{"name":"As","range":"(0,02 - 5) mg/l"},{"name":"B","range":"(0,1 - 10) mg/l"},{"name":"Be","range":"(0,01 - 1,0) mg/l"},{"name":"Ba","range":"(0,01 - 5,0) mg/l"},{"name":"Ca","range":"(1 - 500) mg/l"},{"name":"Cd","range":"(0,01 - 5) mg/l"},{"name":"Co","range":"(0,04 - 10) mg/l"},{"name":"Cr","range":"(0,04 - 10) mg/l"},{"name":"Cu","range":"(0,05 - 5) mg/l"},{"name":"Fe","range":"(0,1 - 30) mg/l"},{"name":"K","range":"(5 - 200) mg/l"},{"name":"Mg","range":"(1 - 100) mg/l"},{"name":"Mn","range":"(0,02 - 10) mg/l"},{"name":"Mo","range":"(0,1 - 10) mg/l"},{"name":"Na","range":"(5 - 2000) mg/l"},{"name":"Ni","range":"(0,04 - 10) mg/l"},{"name":"Pb","range":"(0,3 - 10) mg/l"},{"name":"Sb","range":"(0,2 - 10) mg/l"},{"name":"Se","range":"(0,6 - 10) mg/l"},{"name":"Sn","range":"(0,3 - 2) mg/l"},{"name":"Sr","range":"(0,02 - 2) mg/l"},{"name":"Ti","range":"(0,05 - 2) mg/l"},{"name":"V","range":"(0,2 - 2) mg/l"},{"name":"Zn","range":"(0,05 - 50) mg/l"},{"name":"Al","range":"(0,3 - 10) mg/l"},{"name":"P","range":"(0,3 - 1000) mg/l"}],"search_zh":"水、废水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Ag As B Be Ba Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Sn Sr Ti V Zn Al P PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b2131b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZTCr","parameters":[{"name":"Zakres","range":"(4,0 - 15000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZTCr\nZakres (4,0 - 15000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nZakres (4,0 - 15000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nZakres (4,0 - 15000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - CODCr","parameters_en":[{"name":"Range","range":"(4,0 - 15000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - CODCr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(4,0 - 15000) mg/l O2"}],"search_zh":"水、废水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b2131c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 - 6000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 - 6000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ogólnego węgla organicznego\nZakres (1,0 - 6000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegla organicznego\nZakres (1,0 - 6000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(1,0 - 6000) mg/l"}],"search_en":"Water, wastewater Total organic carbon concentration High-temperature combustion with IR detection Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 - 6000) mg/l"}],"search_zh":"水、废水 总有机碳浓度 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、废水","methodology_zh":"总有机碳浓度"},{"_id":"6a83bcf4af14b9c0e7b2131d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(0,01 - 0,5) mg/l"},{"name":"Stężenie cyjanków wolnych"},{"name":"Zakres","range":"(0,01 - 0,5) mg/l"},{"name":"Stężenie cyjanków związanych (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków ogólnych\nZakres:\nZakres (0,01 - 0,5) mg/l\nStężenie cyjanków wolnych\nZakres (0,01 - 0,5) mg/l\nStężenie cyjanków związanych (z obliczeń)\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-30 wydanie 4 z dnia 31.03.2016 r. w oparciu o test MERCK nr 1.09701.0001","norm_bases":["EKOLAB/LB/PB-30 wydanie 4 z dnia 31.03.2016 r. w oparciu o test MERCK nr 1.09701.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie cyjanków ogólnych\nZakres:\nZakres (0,01 - 0,5) mg/l\nStężenie cyjanków wolnych\nZakres (0,01 - 0,5) mg/l\nStężenie cyjanków związanych (z obliczeń)\nMetoda spektrofotometryczna EKOLAB/LB/PB-30 wydanie 4 z dnia 31.03.2016 r. w oparciu o test MERCK nr 1.09701.0001 Woda, scieki Stezenie cyjankow ogolnych\nZakres:\nZakres (0,01 - 0,5) mg/l\nStezenie cyjankow wolnych\nZakres (0,01 - 0,5) mg/l\nStezenie cyjankow zwiazanych (z obliczen)\nMetoda spektrofotometryczna EKOLAB/LB/PB-30 wydanie 4 z dnia 31.03.2016 r. w oparciu o test MERCK nr 1.09701.0001","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide concentration","parameters_en":[{"name":"Range","range":"(0,01 - 0,5) mg/l"},{"name":"Free cyanide concentration"},{"name":"Range","range":"(0,01 - 0,5) mg/l"},{"name":"Combined cyanide concentration (calculated)"}],"search_en":"Water, wastewater Total cyanide concentration Spectrophotometric method Range Free cyanide concentration Range Combined cyanide concentration (calculated) EKOLAB/LB/PB-30 wydanie 4 z dnia 31.03.2016 r. w oparciu o test MERCK nr 1.09701.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,01 - 0,5) mg/l"},{"name":"游离氰化物浓度"},{"name":"范围","range":"(0,01 - 0,5) mg/l"},{"name":"络合氰化物浓度（由计算得出）"}],"search_zh":"水、废水 总氰化物浓度 分光光度法 范围 游离氰化物浓度 范围 络合氰化物浓度（由计算得出） EKOLAB/LB/PB-30 wydanie 4 z dnia 31.03.2016 r. w oparciu o test MERCK nr 1.09701.0001","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"总氰化物浓度"},{"_id":"6a83bcf4af14b9c0e7b2131e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie formaldehydu","parameters":[{"name":"Zakres","range":"(0,1 - 8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie formaldehydu\nZakres (0,1 - 8) mg/l\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-27 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14500.0001","norm_bases":["EKOLAB/LB/PB-27 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14500.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie formaldehydu\nZakres (0,1 - 8) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-27 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14500.0001 Woda, scieki Stezenie formaldehydu\nZakres (0,1 - 8) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-27 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14500.0001","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,1 - 8) mg/l"}],"search_en":"Water, wastewater Formaldehyde concentration Spectrophotometric method Range EKOLAB/LB/PB-27 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14500.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 8) mg/l"}],"search_zh":"水、废水 甲醛浓度 分光光度法 范围 EKOLAB/LB/PB-27 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14500.0001","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"甲醛浓度"},{"_id":"6a83bcf4af14b9c0e7b2131f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fenoli","parameters":[{"name":"Zakres","range":"(0,002 - 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fenoli\nZakres (0,002 - 50) mg/l\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-57 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.00856.0001","norm_bases":["EKOLAB/LB/PB-57 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.00856.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fenoli\nZakres (0,002 - 50) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-57 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.00856.0001 Woda, scieki Stezenie fenoli\nZakres (0,002 - 50) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-57 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.00856.0001","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,002 - 50) mg/l"}],"search_en":"Water, wastewater Spectrophotometric method Range EKOLAB/LB/PB-57 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.00856.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,002 - 50) mg/l"}],"search_zh":"水、废水 分光光度法 范围 EKOLAB/LB/PB-57 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.00856.0001","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21320","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,2 - 80) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (0,2 - 80) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość ogólna\nZakres (0,2 - 80) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, scieki Zasadowosc ogolna\nZakres (0,2 - 80) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,2 - 80) mmol/l"}],"search_en":"Water, wastewater Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,2 - 80) mmol/l"}],"search_zh":"水、废水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总碱度"},{"_id":"6a83bcf4af14b9c0e7b21321","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wodorowęglanów","parameters":[{"name":"Zakres","range":"(12 - 4800) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wodorowęglanów\nZakres (12 - 4800) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wodorowęglanów\nZakres (12 - 4800) mg/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, scieki Stezenie wodoroweglanow\nZakres (12 - 4800) mg/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bicarbonate concentration","parameters_en":[{"name":"Range","range":"(12 - 4800) mg/l"}],"search_en":"Water, wastewater Bicarbonate concentration Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(12 - 4800) mg/l"}],"search_zh":"水、废水 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21322","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,1 - 75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,1 - 75) mg/l\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","norm_bases":["EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres (0,1 - 75) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001 Woda, scieki Stezenie fosforanow\nZakres (0,1 - 75) mg/l\nMetoda spektrofotometryczna EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,1 - 75) mg/l"}],"search_en":"Water, wastewater Phosphate concentration Spectrophotometric method Range EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 75) mg/l"}],"search_zh":"水、废水 磷酸盐浓度 分光光度法 范围 EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a83bcf4af14b9c0e7b21323","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu fosforanowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie fosforu fosforanowego (z obliczeń)","reference":"EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","norm_bases":["EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu fosforanowego (z obliczeń) EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001 Woda, scieki Stezenie fosforu fosforanowego (z obliczen) EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate phosphorus concentration (calculated)","search_en":"Water, wastewater Phosphate phosphorus concentration (calculated) EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","test_object_en":"Water, wastewater","search_zh":"水、废水 EKOLAB/LB/PB-53 wydanie 3 z dnia 06.05.2011 r. wg testu MERCK nr 1.14848.0001","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21324","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5,0 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5,0 - 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (5,0 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (5,0 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5,0 - 5000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 5000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21325","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,5 - 1000) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,5 - 1000) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03","norm_bases":["PN-78/C-04588/03"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fluorków\nZakres (0,5 - 1000) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 Woda, scieki Stezenie fluorkow\nZakres (0,5 - 1000) mg/l\nMetoda potencjometryczna PN-78/C-04588/03","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,5 - 1000) mg/l"}],"search_en":"Water, wastewater Fluoride concentration Potentiometric method Range PN-78/C-04588/03","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 - 1000) mg/l"}],"search_zh":"水、废水 氟化物浓度 电位法 范围 PN-78/C-04588/03","technique_zh":"电位法","test_object_zh":"水、废水","methodology_zh":"氟化物浓度"},{"_id":"6a83bcf4af14b9c0e7b21326","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji organicznych ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 - 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (10 - 3000) mg/l\nMetoda wagowa","reference":"EKOLAB/LB/PB-74 wydanie 4 z dnia 06.05.2011 r.","norm_bases":["EKOLAB/LB/PB-74 wydanie 4 z dnia 06.05.2011 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (10 - 3000) mg/l\nMetoda wagowa EKOLAB/LB/PB-74 wydanie 4 z dnia 06.05.2011 r. Woda, scieki Stezenie substancji organicznych ekstrahujacych sie eterem naftowym\nZakres (10 - 3000) mg/l\nMetoda wagowa EKOLAB/LB/PB-74 wydanie 4 z dnia 06.05.2011 r.","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10 - 3000) mg/l"}],"search_en":"Water, wastewater Concentration of organic substances extractable with petroleum ether Gravimetric method Range EKOLAB/LB/PB-74 wydanie 4 z dnia 06.05.2011 r.","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 - 3000) mg/l"}],"search_zh":"水、废水 石油醚可萃取有机物质浓度 重量法 范围 EKOLAB/LB/PB-74 wydanie 4 z dnia 06.05.2011 r.","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取有机物质浓度"},{"_id":"6a83bcf4af14b9c0e7b21327","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 - 7000) mg/l"},{"name":"Stężenie chlorków"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres:\nZakres (5 - 7000) mg/l\nStężenie chlorków\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres:\nZakres (5 - 7000) mg/l\nStężenie chlorków\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres:\nZakres (5 - 7000) mg/l\nStezenie chlorkow\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 - 7000) mg/l"},{"name":"Chloride concentration"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range Chloride concentration PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 7000) mg/l"},{"name":"氯化物浓度"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 氯化物浓度 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21328","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,02 - 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,02 - 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów\nZakres (0,02 - 40) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotynow\nZakres (0,02 - 40) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,02 - 40) mg/l"}],"search_en":"Water, wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,02 - 40) mg/l"}],"search_zh":"水、废水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21329","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotynowego (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego (z obliczeń) PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration (calculated)","search_en":"Water, wastewater Nitrite nitrogen concentration (calculated) PN-EN 26777:1999","test_object_en":"Water, wastewater","search_zh":"水、废水 亚硝酸盐氮浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐氮浓度（由计算得出）"},{"_id":"6a83bcf4af14b9c0e7b2132a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chromu (III) i chromu (VI)","parameters":[{"name":"Zakres","range":"(0,01 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (III) i chromu (VI)\nZakres (0,01 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604-08","norm_bases":["PN-77/C-04604-08"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chromu (III) i chromu (VI)\nZakres (0,01 - 1,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604-08 Woda, scieki Stezenie chromu (III) i chromu (VI)\nZakres (0,01 - 1,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604-08","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium (III) and chromium (VI) concentration","parameters_en":[{"name":"Range","range":"(0,01 - 1,0) mg/l"}],"search_en":"Water, wastewater Chromium (III) and chromium (VI) concentration Spectrophotometric method Range PN-77/C-04604-08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,01 - 1,0) mg/l"}],"search_zh":"水、废水 分光光度法 范围 PN-77/C-04604-08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b2132b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny łatwo opadające","parameters":[{"name":"Zakres","range":"(0,1 - 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwo opadające\nZakres (0,1 - 100) ml/l\nMetoda objętościowa","reference":"EKOLAB/LB/PB-50 wydanie 2 z dnia 06.05.2011 r.","norm_bases":["EKOLAB/LB/PB-50 wydanie 2 z dnia 06.05.2011 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny łatwo opadające\nZakres (0,1 - 100) ml/l\nMetoda objętościowa EKOLAB/LB/PB-50 wydanie 2 z dnia 06.05.2011 r. Woda, scieki Zawiesiny latwo opadajace\nZakres (0,1 - 100) ml/l\nMetoda objetosciowa EKOLAB/LB/PB-50 wydanie 2 z dnia 06.05.2011 r.","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,1 - 100) ml/l"}],"search_en":"Water, wastewater Settleable solids Volumetric method Range EKOLAB/LB/PB-50 wydanie 2 z dnia 06.05.2011 r.","technique_en":"Volumetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 100) ml/l"}],"search_zh":"水、废水 易沉降悬浮物 容量法 范围 EKOLAB/LB/PB-50 wydanie 2 z dnia 06.05.2011 r.","test_object_zh":"水、废水","technique_zh":"容量法","methodology_zh":"易沉降悬浮物"},{"_id":"6a83bcf4af14b9c0e7b2132c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,1 - 40) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (0,1 - 40) g/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Sucha pozostalosc\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,1 - 40) g/l"}],"search_en":"Water, wastewater Dry residue Gravimetric method Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 40) g/l"}],"search_zh":"水、废水 干残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"干残渣"},{"_id":"6a83bcf4af14b9c0e7b2132d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(0,1 - 40) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po prażeniu\nZakres (0,1 - 40) g/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Pozostałość po prażeniu\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Pozostalosc po prazeniu\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue on ignition","parameters_en":[{"name":"Range","range":"(0,1 - 40) g/l"}],"search_en":"Water, wastewater Residue on ignition Gravimetric method Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 40) g/l"}],"search_zh":"水、废水 灼烧残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"灼烧残渣"},{"_id":"6a83bcf4af14b9c0e7b2132e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,1 - 40) g/l"},{"name":"Stężenie substancji rozpuszczonych"},{"name":"Zakres","range":"(0,1 - 40) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji rozpuszczonych\nZakres:\nZakres (0,1 - 40) g/l\nStężenie substancji rozpuszczonych\nZakres (0,1 - 40) g/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji rozpuszczonych\nZakres:\nZakres (0,1 - 40) g/l\nStężenie substancji rozpuszczonych\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Stezenie substancji rozpuszczonych\nZakres:\nZakres (0,1 - 40) g/l\nStezenie substancji rozpuszczonych\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids concentration","parameters_en":[{"name":"Range","range":"(0,1 - 40) g/l"},{"name":"Dissolved solids concentration"},{"name":"Range","range":"(0,1 - 40) g/l"}],"search_en":"Water, wastewater Dissolved solids concentration Gravimetric method Range Dissolved solids concentration Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 40) g/l"},{"name":"溶解性物质浓度"},{"name":"范围","range":"(0,1 - 40) g/l"}],"search_zh":"水、废水 溶解性物质浓度 重量法 范围 溶解性物质浓度 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性物质浓度"},{"_id":"6a83bcf4af14b9c0e7b2132f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji mineralnych","parameters":[{"name":"Zakres","range":"(0,1 - 40) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji mineralnych\nZakres (0,1 - 40) g/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji mineralnych\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Stezenie substancji mineralnych\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of mineral substances","parameters_en":[{"name":"Range","range":"(0,1 - 40) g/l"}],"search_en":"Water, wastewater Concentration of mineral substances Gravimetric method Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 40) g/l"}],"search_zh":"水、废水 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21330","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji lotnych","parameters":[{"name":"Zakres","range":"(0,1 - 40) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji lotnych\nZakres (0,1 - 40) g/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji lotnych\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Stezenie substancji lotnych\nZakres (0,1 - 40) g/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile substances","parameters_en":[{"name":"Range","range":"(0,1 - 40) g/l"}],"search_en":"Water, wastewater Concentration of volatile substances Gravimetric method Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 - 40) g/l"}],"search_zh":"水、废水 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21331","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,100 - 40,0) g/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji rozpuszczonych\nZakres (0,100 - 40,0) g/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji rozpuszczonych\nZakres (0,100 - 40,0) g/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Stezenie substancji rozpuszczonych\nZakres (0,100 - 40,0) g/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids concentration","parameters_en":[{"name":"Range","range":"(0,100 - 40,0) g/l"}],"search_en":"Water, wastewater Dissolved solids concentration Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,100 - 40,0) g/l"}],"search_zh":"水、废水 溶解性物质浓度 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性物质浓度"},{"_id":"6a83bcf4af14b9c0e7b21332","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,10 - 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,10 - 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru wolnego\nZakres (0,10 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, scieki Stezenie chloru wolnego\nZakres (0,10 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 - 5,0) mg/l"}],"search_en":"Water, wastewater Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 5,0) mg/l"}],"search_zh":"水、废水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21333","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chloru ogólnego/całkowitego","parameters":[{"name":"Zakres","range":"(0,10 - 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego/całkowitego\nZakres (0,10 - 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chloru ogólnego/całkowitego\nZakres (0,10 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, scieki Stezenie chloru ogolnego/calkowitego\nZakres (0,10 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,10 - 5,0) mg/l"}],"search_en":"Water, wastewater Total chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 5,0) mg/l"}],"search_zh":"水、废水 总氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"总氯浓度"},{"_id":"6a83bcf4af14b9c0e7b21334","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(5 - 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5 - 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (5 - 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (5 - 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(5 - 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5 - 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a83bcf4af14b9c0e7b21335","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie węglowodorów aromatycznych","parameters":[{"name":"benzen","range":"(0,005 - 17) mg/l"},{"name":"toluen","range":"(0,005 - 17) mg/l"},{"name":"kumen","range":"(0,005 - 16) mg/l"},{"name":"o-,m-,p-ksylen","range":"(0,005 - 16) mg/l"},{"name":"etylobenzen","range":"(0,005 - 20) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,005 - 17) mg/l\ntoluen (0,005 - 17) mg/l\nkumen (0,005 - 16) mg/l\no-,m-,p-ksylen (0,005 - 16) mg/l\netylobenzen (0,005 - 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EKOLAB/LB/PB-58 wydanie 5 z dnia 15.10.2012 r.","norm_bases":["EKOLAB/LB/PB-58 wydanie 5 z dnia 15.10.2012 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie węglowodorów aromatycznych\nZakres:\nbenzen (0,005 - 17) mg/l\ntoluen (0,005 - 17) mg/l\nkumen (0,005 - 16) mg/l\no-,m-,p-ksylen (0,005 - 16) mg/l\netylobenzen (0,005 - 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EKOLAB/LB/PB-58 wydanie 5 z dnia 15.10.2012 r. Woda, scieki Stezenie weglowodorow aromatycznych\nZakres:\nbenzen (0,005 - 17) mg/l\ntoluen (0,005 - 17) mg/l\nkumen (0,005 - 16) mg/l\no-,m-,p-ksylen (0,005 - 16) mg/l\netylobenzen (0,005 - 20) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EKOLAB/LB/PB-58 wydanie 5 z dnia 15.10.2012 r.","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of aromatic hydrocarbons","parameters_en":[{"name":"benzene","range":"(0,005 - 17) mg/l"},{"name":"toluene","range":"(0,005 - 17) mg/l"},{"name":"cumene","range":"(0,005 - 16) mg/l"},{"name":"o-,m-,p-xylene","range":"(0,005 - 16) mg/l"},{"name":"ethylbenzene","range":"(0,005 - 20) mg/l"}],"search_en":"Water, wastewater Concentration of aromatic hydrocarbons Gas chromatography with flame ionization detection (GC-FID) benzene toluene cumene o-,m-,p-xylene ethylbenzene EKOLAB/LB/PB-58 wydanie 5 z dnia 15.10.2012 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","search_zh":"水、废水 芳香烃浓度 气相色谱-氢火焰离子化检测法（GC-FID） 苯 甲苯 异丙苯 乙苯 EKOLAB/LB/PB-58 wydanie 5 z dnia 15.10.2012 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","parameters_zh":[{"name":"苯","range":"(0,005 - 17) mg/l"},{"name":"甲苯","range":"(0,005 - 17) mg/l"},{"name":"异丙苯","range":"(0,005 - 16) mg/l"},{"name":"o-,m-,p-ksylen","range":"(0,005 - 16) mg/l"},{"name":"乙苯","range":"(0,005 - 20) mg/l"}],"methodology_zh":"芳香烃浓度"},{"_id":"6a83bcf4af14b9c0e7b21336","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Wody opadowe, wody roztopowe","methodology":"Indeks oleju mineralnego (C10 - C40)","parameters":[{"name":"Zakres","range":"(0,05 - 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego (C10 - C40)\nZakres (0,05 - 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Wody opadowe, wody roztopowe Indeks oleju mineralnego (C10 - C40)\nZakres (0,05 - 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki, Wody opadowe, wody roztopowe Indeks oleju mineralnego (C10 - C40)\nZakres (0,05 - 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index (C10 - C40)","parameters_en":[{"name":"Range","range":"(0,05 - 100) mg/l"}],"search_en":"Water, wastewater, Rainwater, snowmelt water Mineral oil index (C10 - C40) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater, Rainwater, snowmelt water","parameters_zh":[{"name":"范围","range":"(0,05 - 100) mg/l"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83bcf4af14b9c0e7b21337","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Wody opadowe, wody roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2 - 7000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2 - 7000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2 - 7000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki, Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2 - 7000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2 - 7000) mg/l"}],"search_en":"Water, wastewater, Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater, Rainwater, snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 - 7000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a83bcf4af14b9c0e7b21338","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,10 - 400) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,10 - 400) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,10 - 400) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,10 - 400) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,10 - 400) mg/l"}],"search_en":"Water, wastewater, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 400) mg/l"}],"search_zh":"水、废水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21339","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu amonowego (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Stężenie azotu amonowego (z obliczeń) PN-ISO 7150-1:2002 Woda, scieki, Woda do spozycia przez ludzi Stezenie azotu amonowego (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration (calculated)","search_en":"Water, wastewater, Water intended for human consumption Ammonium nitrogen concentration (calculated) PN-ISO 7150-1:2002","test_object_en":"Water, wastewater, Water intended for human consumption","search_zh":"水、废水、生活饮用水 铵态氮浓度（由计算得出） PN-ISO 7150-1:2002","test_object_zh":"水、废水、生活饮用水","methodology_zh":"铵态氮浓度（由计算得出）"},{"_id":"6a83bcf4af14b9c0e7b2133a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(0,05 - 15) mmol/l"},{"name":"Zakres","range":"(5 - 1500) mg/l (CaCO3)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna\nZakres:\nZakres (0,05 - 15) mmol/l\nZakres (5 - 1500) mg/l (CaCO3)\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (0,05 - 15) mmol/l\nZakres (5 - 1500) mg/l (CaCO3)\nMetoda miareczkowa PN-ISO 6059:1999 Woda, scieki, Woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (0,05 - 15) mmol/l\nZakres (5 - 1500) mg/l (CaCO3)\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(0,05 - 15) mmol/l"},{"name":"Range","range":"(5 - 1500) mg/l (CaCO3)"}],"search_en":"Water, wastewater, Water intended for human consumption Total hardness Titrimetric method Range Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 - 15) mmol/l"},{"name":"范围","range":"(5 - 1500) mg/l (CaCO3)"}],"search_zh":"水、废水、生活饮用水 总硬度 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","methodology_zh":"总硬度","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2133b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia i magnezu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie wapnia i magnezu","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Stężenie wapnia i magnezu PN-C-04554-4:1999 Woda, scieki, Woda do spozycia przez ludzi Stezenie wapnia i magnezu PN-C-04554-4:1999","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium and magnesium concentration","search_en":"Water, wastewater, Water intended for human consumption Calcium and magnesium concentration PN-C-04554-4:1999","test_object_en":"Water, wastewater, Water intended for human consumption","search_zh":"水、废水、生活饮用水 钙与镁浓度 PN-C-04554-4:1999","test_object_zh":"水、废水、生活饮用水","methodology_zh":"钙与镁浓度"},{"_id":"6a83bcf4af14b9c0e7b2133c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(0,05 - 15) mmol/l"},{"name":"Zakres","range":"(5 - 1500) mg/l (CaCO3)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna\nZakres:\nZakres (0,05 - 15) mmol/l\nZakres (5 - 1500) mg/l (CaCO3)\nMetoda miareczkowa","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Twardość ogólna\nZakres:\nZakres (0,05 - 15) mmol/l\nZakres (5 - 1500) mg/l (CaCO3)\nMetoda miareczkowa PN-C-04554-4:1999 Woda, scieki, Woda do spozycia przez ludzi Twardosc ogolna\nZakres:\nZakres (0,05 - 15) mmol/l\nZakres (5 - 1500) mg/l (CaCO3)\nMetoda miareczkowa PN-C-04554-4:1999","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(0,05 - 15) mmol/l"},{"name":"Range","range":"(5 - 1500) mg/l (CaCO3)"}],"search_en":"Water, wastewater, Water intended for human consumption Total hardness Titrimetric method Range Range PN-C-04554-4:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 - 15) mmol/l"},{"name":"范围","range":"(5 - 1500) mg/l (CaCO3)"}],"search_zh":"水、废水、生活饮用水 总硬度 滴定法 范围 范围 PN-C-04554-4:1999","technique_zh":"滴定法","methodology_zh":"总硬度","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2133d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 - 600) mg/l"},{"name":"Stężenie wapnia"},{"name":"Zakres","range":"(2 - 600) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres:\nZakres (2 - 600) mg/l\nStężenie wapnia\nZakres (2 - 600) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Stężenie wapnia\nZakres:\nZakres (2 - 600) mg/l\nStężenie wapnia\nZakres (2 - 600) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, scieki, Woda do spozycia przez ludzi Stezenie wapnia\nZakres:\nZakres (2 - 600) mg/l\nStezenie wapnia\nZakres (2 - 600) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2 - 600) mg/l"},{"name":"Calcium concentration"},{"name":"Range","range":"(2 - 600) mg/l"}],"search_en":"Water, wastewater, Water intended for human consumption Calcium concentration Titrimetric method Range Calcium concentration Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2 - 600) mg/l"},{"name":"钙浓度"},{"name":"范围","range":"(2 - 600) mg/l"}],"search_zh":"水、废水、生活饮用水 钙浓度 滴定法 范围 钙浓度 范围 PN-ISO 6058:1999","technique_zh":"滴定法","methodology_zh":"钙浓度","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2133e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 - 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 - 300) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 - 300) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, scieki, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 - 300) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 - 300) mg/l"}],"search_en":"Water, wastewater, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 - 300) mg/l"}],"search_zh":"水、废水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b2133f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(1 - 100) mg/l (Pt)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (1 - 100) mg/l (Pt)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012","norm_bases":["PN-EN ISO 7887:2012"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Barwa\nZakres (1 - 100) mg/l (Pt)\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Woda, scieki, Woda do spozycia przez ludzi Barwa\nZakres (1 - 100) mg/l (Pt)\nMetoda spektrofotometryczna PN-EN ISO 7887:2012","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(1 - 100) mg/l (Pt)"}],"search_en":"Water, wastewater, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(1 - 100) mg/l (Pt)"}],"search_zh":"水、废水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012","technique_zh":"分光光度法","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21340","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki, Woda do spozycia przez ludzi pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"Water, wastewater, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"水、废水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21341","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"10 μS/cm - 6000 μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 10 μS/cm - 6000 μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres 10 μS/cm - 6000 μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres 10 μS/cm - 6000 μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"10 μS/cm - 6000 μS/cm"}],"search_en":"Water, wastewater, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"10 μS/cm - 6000 μS/cm"}],"search_zh":"水、废水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21342","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu","parameters":[{"name":"Zakres","range":"(2 - 600) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie magnezu\nZakres (2 - 600) mg/l\nMetoda miareczkowa","reference":"PN-C-04554-4:1999 | PN-ISO 6059:1999","norm_bases":["PN-C-04554-4:1999","PN-ISO 6059:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Stężenie magnezu\nZakres (2 - 600) mg/l\nMetoda miareczkowa PN-C-04554-4:1999 | PN-ISO 6059:1999 Woda, scieki, Woda do spozycia przez ludzi Stezenie magnezu\nZakres (2 - 600) mg/l\nMetoda miareczkowa PN-C-04554-4:1999 | PN-ISO 6059:1999","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration","parameters_en":[{"name":"Range","range":"(2 - 600) mg/l"}],"search_en":"Water, wastewater, Water intended for human consumption Magnesium concentration Titrimetric method Range PN-C-04554-4:1999 | PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, wastewater, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2 - 600) mg/l"}],"search_zh":"水、废水、生活饮用水 镁浓度 滴定法 范围 PN-C-04554-4:1999 | PN-ISO 6059:1999","technique_zh":"滴定法","methodology_zh":"镁浓度","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21343","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"benzo(a)antracen","range":"(0,01 - 5) μg/l"},{"name":"chryzen","range":"(0,01 - 5) μg/l"},{"name":"benzo(b)fluoranten","range":"(0,005 - 2) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,01 - 2) μg/l"},{"name":"benzo(a)piren","range":"(0,005 - 2) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,01 - 5) μg/l"},{"name":"indeno(123-cd)piren","range":"(0,01 - 5) μg/l"},{"name":"naftalen","range":"(0,01 - 5) μg/l"},{"name":"fenantren","range":"(0,01 - 5) μg/l"},{"name":"fluoranten","range":"(0,01 - 5) μg/l"},{"name":"piren","range":"(0,05 - 5) μg/l"},{"name":"antracen","range":"(0,01 - 5) μg/l"},{"name":"acenaften","range":"(0,01 - 5) μg/l"},{"name":"dibenzo(ah)antracen","range":"(0,01 - 5) μg/l"},{"name":"fluoren","range":"(0,01 - 5) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(a)antracen (0,01 - 5) μg/l\nchryzen (0,01 - 5) μg/l\nbenzo(b)fluoranten (0,005 - 2) μg/l\nbenzo(k)fluoranten (0,01 - 2) μg/l\nbenzo(a)piren (0,005 - 2) μg/l\nbenzo(ghi)perylen (0,01 - 5) μg/l\nindeno(123-cd)piren (0,01 - 5) μg/l\nnaftalen (0,01 - 5) μg/l\nfenantren (0,01 - 5) μg/l\nfluoranten (0,01 - 5) μg/l\npiren (0,05 - 5) μg/l\nantracen (0,01 - 5) μg/l\nacenaften (0,01 - 5) μg/l\ndibenzo(ah)antracen (0,01 - 5) μg/l\nfluoren (0,01 - 5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(a)antracen (0,01 - 5) μg/l\nchryzen (0,01 - 5) μg/l\nbenzo(b)fluoranten (0,005 - 2) μg/l\nbenzo(k)fluoranten (0,01 - 2) μg/l\nbenzo(a)piren (0,005 - 2) μg/l\nbenzo(ghi)perylen (0,01 - 5) μg/l\nindeno(123-cd)piren (0,01 - 5) μg/l\nnaftalen (0,01 - 5) μg/l\nfenantren (0,01 - 5) μg/l\nfluoranten (0,01 - 5) μg/l\npiren (0,05 - 5) μg/l\nantracen (0,01 - 5) μg/l\nacenaften (0,01 - 5) μg/l\ndibenzo(ah)antracen (0,01 - 5) μg/l\nfluoren (0,01 - 5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda, scieki, Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nbenzo(a)antracen (0,01 - 5) μg/l\nchryzen (0,01 - 5) μg/l\nbenzo(b)fluoranten (0,005 - 2) μg/l\nbenzo(k)fluoranten (0,01 - 2) μg/l\nbenzo(a)piren (0,005 - 2) μg/l\nbenzo(ghi)perylen (0,01 - 5) μg/l\nindeno(123-cd)piren (0,01 - 5) μg/l\nnaftalen (0,01 - 5) μg/l\nfenantren (0,01 - 5) μg/l\nfluoranten (0,01 - 5) μg/l\npiren (0,05 - 5) μg/l\nantracen (0,01 - 5) μg/l\nacenaften (0,01 - 5) μg/l\ndibenzo(ah)antracen (0,01 - 5) μg/l\nfluoren (0,01 - 5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"benzo(a)anthracene","range":"(0,01 - 5) μg/l"},{"name":"chrysene","range":"(0,01 - 5) μg/l"},{"name":"benzo(b)fluoranthene","range":"(0,005 - 2) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,01 - 2) μg/l"},{"name":"benzo(a)pyrene","range":"(0,005 - 2) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,01 - 5) μg/l"},{"name":"indeno(123-cd)pyrene","range":"(0,01 - 5) μg/l"},{"name":"naphthalene","range":"(0,01 - 5) μg/l"},{"name":"phenanthrene","range":"(0,01 - 5) μg/l"},{"name":"fluoranthene","range":"(0,01 - 5) μg/l"},{"name":"pyrene","range":"(0,05 - 5) μg/l"},{"name":"anthracene","range":"(0,01 - 5) μg/l"},{"name":"acenaphthene","range":"(0,01 - 5) μg/l"},{"name":"dibenzo(ah)anthracene","range":"(0,01 - 5) μg/l"},{"name":"fluorene","range":"(0,01 - 5) μg/l"}],"search_en":"Water, wastewater, Water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene indeno(123-cd)pyrene naphthalene phenanthrene fluoranthene pyrene anthracene acenaphthene dibenzo(ah)anthracene fluorene PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, wastewater, Water intended for human consumption","search_zh":"水、废水、生活饮用水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并（a）蒽 䓛 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 苯并（ghi）苝 萘 菲 荧蒽 芘 蒽 苊 二苯并(ah)蒽 芴 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","parameters_zh":[{"name":"苯并（a）蒽","range":"(0,01 - 5) μg/l"},{"name":"䓛","range":"(0,01 - 5) μg/l"},{"name":"苯并（b）荧蒽","range":"(0,005 - 2) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,01 - 2) μg/l"},{"name":"苯并（a）芘","range":"(0,005 - 2) μg/l"},{"name":"苯并（ghi）苝","range":"(0,01 - 5) μg/l"},{"name":"indeno(123-cd)piren","range":"(0,01 - 5) μg/l"},{"name":"萘","range":"(0,01 - 5) μg/l"},{"name":"菲","range":"(0,01 - 5) μg/l"},{"name":"荧蒽","range":"(0,01 - 5) μg/l"},{"name":"芘","range":"(0,05 - 5) μg/l"},{"name":"蒽","range":"(0,01 - 5) μg/l"},{"name":"苊","range":"(0,01 - 5) μg/l"},{"name":"二苯并(ah)蒽","range":"(0,01 - 5) μg/l"},{"name":"芴","range":"(0,01 - 5) μg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21344","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Woda, ścieki, Woda do spożycia przez ludzi","methodology":"Suma WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma WWA (z obliczeń)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Woda do spożycia przez ludzi Suma WWA (z obliczeń) PN-EN ISO 17993:2005 Woda, scieki, Woda do spozycia przez ludzi Suma WWA (z obliczen) PN-EN ISO 17993:2005","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of PAH (calculated)","search_en":"Water, wastewater, Water intended for human consumption Sum of PAH (calculated) PN-EN ISO 17993:2005","test_object_en":"Water, wastewater, Water intended for human consumption","methodology_zh":"多环芳烃总量（计算值）","search_zh":"水、废水、生活饮用水 多环芳烃总量（计算值） PN-EN ISO 17993:2005","test_object_zh":"水、废水、生活饮用水"},{"_id":"6a83bcf4af14b9c0e7b21345","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,1 - 99) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,1 - 99) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa / zawartość wody\nZakres (0,1 - 99) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Sucha masa / zawartosc wody\nZakres (0,1 - 99) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,1 - 99) %"}],"search_en":"Soil Dry matter / water content Gravimetric method Range PN-ISO 11465:1999","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,1 - 99) %"}],"search_zh":"土壤 干物质 / 水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质 / 水分含量"},{"_id":"6a83bcf4af14b9c0e7b21346","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartości węgla organicznego","parameters":[{"name":"Zakres","range":"(1 - 350) g/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartości węgla organicznego\nZakres (1 - 350) g/kg\nMetoda spektrofotometryczna","reference":"PN-ISO 14235:2003","norm_bases":["PN-ISO 14235:2003"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartości węgla organicznego\nZakres (1 - 350) g/kg\nMetoda spektrofotometryczna PN-ISO 14235:2003 Gleba Zawartosci wegla organicznego\nZakres (1 - 350) g/kg\nMetoda spektrofotometryczna PN-ISO 14235:2003","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic carbon content","parameters_en":[{"name":"Range","range":"(1 - 350) g/kg"}],"search_en":"Soil Organic carbon content Spectrophotometric method Range PN-ISO 14235:2003","technique_en":"Spectrophotometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1 - 350) g/kg"}],"search_zh":"土壤 分光光度法 范围 PN-ISO 14235:2003","technique_zh":"分光光度法","test_object_zh":"土壤"},{"_id":"6a83bcf4af14b9c0e7b21347","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w KCl, pH - w H2O","parameters":[{"name":"Zakres","range":"2,0 - 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w KCl, pH - w H2O\nZakres 2,0 - 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w KCl, pH - w H2O\nZakres 2,0 - 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w KCl, pH - w H2O\nZakres 2,0 - 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in KCl, pH - in H2O","parameters_en":[{"name":"Range","range":"2,0 - 11,0"}],"search_en":"Soil pH - in KCl, pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 - 11,0"}],"search_zh":"土壤 pH － 于 KCl 中，pH － 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH － 于 KCl 中，pH － 于 H2O 中"},{"_id":"6a83bcf4af14b9c0e7b21348","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,10 - 50,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,10 - 50,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012+ Ap1:2016-07E","norm_bases":["PN-EN 16174:2012 Metoda B,","PN-EN ISO 12846:2012+ Ap1:2016-07E"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość rtęci\nZakres (0,10 - 50,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012+ Ap1:2016-07E Gleba Zawartosc rteci\nZakres (0,10 - 50,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012+ Ap1:2016-07E","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,10 - 50,0) mg/kg"}],"search_en":"Soil Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Soil","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,10 - 50,0) mg/kg"}],"search_zh":"土壤 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"土壤"},{"_id":"6a83bcf4af14b9c0e7b21349","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"naftalen","range":"(0,020 - 10,0) mg/kg"},{"name":"fenantren","range":"(0,020 - 10) mg/kg"},{"name":"antracen","range":"(0,020 - 10,0) mg/kg"},{"name":"fluoranten","range":"(0,020 - 10,0) mg/kg"},{"name":"chryzen","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(a)antracen","range":"(0,020 - 10,0) mg/kg"},{"name":"dibenzo(a,h)antracen"},{"name":"Zakres","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(a)piren","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(b)fluoranten","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(k)fluoranten","range":"(0,020 - 10,0) mg/kg"},{"name":"acenaften","range":"(0,020 - 10,0) mg/kg"},{"name":"fluoren","range":"(0,020 - 10,0) mg/kg"},{"name":"piren","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(ghi)perylen","range":"(0,020 - 10,0) mg/kg"},{"name":"indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,020 - 10,0) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,020 - 10,0) mg/kg\nfenantren (0,020 - 10) mg/kg\nantracen (0,020 - 10,0) mg/kg\nfluoranten (0,020 - 10,0) mg/kg\nchryzen (0,020 - 10,0) mg/kg\nbenzo(a)antracen (0,020 - 10,0) mg/kg\ndibenzo(a,h)antracen\nZakres (0,020 - 10,0) mg/kg\nbenzo(a)piren (0,020 - 10,0) mg/kg\nbenzo(b)fluoranten (0,020 - 10,0) mg/kg\nbenzo(k)fluoranten (0,020 - 10,0) mg/kg\nacenaften (0,020 - 10,0) mg/kg\nfluoren (0,020 - 10,0) mg/kg\npiren (0,020 - 10,0) mg/kg\nbenzo(ghi)perylen (0,020 - 10,0) mg/kg\nindeno (1,2,3-c,d)piren\n(0,020 - 10,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-ISO 13877:2004","norm_bases":["PN-ISO 13877:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nnaftalen (0,020 - 10,0) mg/kg\nfenantren (0,020 - 10) mg/kg\nantracen (0,020 - 10,0) mg/kg\nfluoranten (0,020 - 10,0) mg/kg\nchryzen (0,020 - 10,0) mg/kg\nbenzo(a)antracen (0,020 - 10,0) mg/kg\ndibenzo(a,h)antracen\nZakres (0,020 - 10,0) mg/kg\nbenzo(a)piren (0,020 - 10,0) mg/kg\nbenzo(b)fluoranten (0,020 - 10,0) mg/kg\nbenzo(k)fluoranten (0,020 - 10,0) mg/kg\nacenaften (0,020 - 10,0) mg/kg\nfluoren (0,020 - 10,0) mg/kg\npiren (0,020 - 10,0) mg/kg\nbenzo(ghi)perylen (0,020 - 10,0) mg/kg\nindeno (1,2,3-c,d)piren\n(0,020 - 10,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-ISO 13877:2004 Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nnaftalen (0,020 - 10,0) mg/kg\nfenantren (0,020 - 10) mg/kg\nantracen (0,020 - 10,0) mg/kg\nfluoranten (0,020 - 10,0) mg/kg\nchryzen (0,020 - 10,0) mg/kg\nbenzo(a)antracen (0,020 - 10,0) mg/kg\ndibenzo(a,h)antracen\nZakres (0,020 - 10,0) mg/kg\nbenzo(a)piren (0,020 - 10,0) mg/kg\nbenzo(b)fluoranten (0,020 - 10,0) mg/kg\nbenzo(k)fluoranten (0,020 - 10,0) mg/kg\nacenaften (0,020 - 10,0) mg/kg\nfluoren (0,020 - 10,0) mg/kg\npiren (0,020 - 10,0) mg/kg\nbenzo(ghi)perylen (0,020 - 10,0) mg/kg\nindeno (1,2,3-c,d)piren\n(0,020 - 10,0) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-ISO 13877:2004","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"naphthalene","range":"(0,020 - 10,0) mg/kg"},{"name":"phenanthrene","range":"(0,020 - 10) mg/kg"},{"name":"anthracene","range":"(0,020 - 10,0) mg/kg"},{"name":"fluoranthene","range":"(0,020 - 10,0) mg/kg"},{"name":"chrysene","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(a)anthracene","range":"(0,020 - 10,0) mg/kg"},{"name":"dibenzo(a,h)anthracene"},{"name":"Range","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(a)pyrene","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(b)fluoranthene","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(k)fluoranthene","range":"(0,020 - 10,0) mg/kg"},{"name":"acenaphthene","range":"(0,020 - 10,0) mg/kg"},{"name":"fluorene","range":"(0,020 - 10,0) mg/kg"},{"name":"pyrene","range":"(0,020 - 10,0) mg/kg"},{"name":"benzo(ghi)perylene","range":"(0,020 - 10,0) mg/kg"},{"name":"indeno","range":"(1,2,3-c,d)piren"},{"name":"(0,020 - 10,0) mg/kg"}],"search_en":"Soil Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) naphthalene phenanthrene anthracene fluoranthene chrysene benzo(a)anthracene dibenzo(a,h)anthracene Range benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene acenaphthene fluorene pyrene benzo(ghi)perylene indeno (0,020 - 10,0) mg/kg PN-ISO 13877:2004","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Soil","parameters_zh":[{"name":"萘","range":"(0,020 - 10,0) mg/kg"},{"name":"菲","range":"(0,020 - 10) mg/kg"},{"name":"蒽","range":"(0,020 - 10,0) mg/kg"},{"name":"荧蒽","range":"(0,020 - 10,0) mg/kg"},{"name":"䓛","range":"(0,020 - 10,0) mg/kg"},{"name":"苯并（a）蒽","range":"(0,020 - 10,0) mg/kg"},{"name":"二苯并（a,h）蒽"},{"name":"范围","range":"(0,020 - 10,0) mg/kg"},{"name":"苯并（a）芘","range":"(0,020 - 10,0) mg/kg"},{"name":"苯并（b）荧蒽","range":"(0,020 - 10,0) mg/kg"},{"name":"苯并（k）荧蒽","range":"(0,020 - 10,0) mg/kg"},{"name":"苊","range":"(0,020 - 10,0) mg/kg"},{"name":"芴","range":"(0,020 - 10,0) mg/kg"},{"name":"芘","range":"(0,020 - 10,0) mg/kg"},{"name":"苯并（ghi）苝","range":"(0,020 - 10,0) mg/kg"},{"name":"茚","range":"(1,2,3-c,d)piren"},{"name":"(0,020 - 10,0) mg/kg"}],"search_zh":"土壤 多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） 萘 菲 蒽 荧蒽 䓛 苯并（a）蒽 二苯并（a,h）蒽 范围 苯并（a）芘 苯并（b）荧蒽 苯并（k）荧蒽 苊 芴 芘 苯并（ghi）苝 茚 PN-ISO 13877:2004","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"土壤","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a83bcf4af14b9c0e7b2134a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Suma WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma WWA (z obliczeń)","reference":"PN-ISO 13877:2004","norm_bases":["PN-ISO 13877:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Suma WWA (z obliczeń) PN-ISO 13877:2004 Gleba Suma WWA (z obliczen) PN-ISO 13877:2004","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of PAH (calculated)","search_en":"Soil Sum of PAH (calculated) PN-ISO 13877:2004","test_object_en":"Soil","search_zh":"土壤 多环芳烃总量（计算值） PN-ISO 13877:2004","test_object_zh":"土壤","methodology_zh":"多环芳烃总量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b2134b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość pierwiastków, Zakres : As (10,0 - 200) mg/kg, Ba (10,0 - 3000) mg/kg, Cd (0,50 - 250) mg/kg, Co (5,0 - 500) mg/kg, Cr (5,0 - 1000) mg/kg, Cu (5,0 - 1000) mg/kg, Fe (10,0 - 750) mg/kg, Mn (10,0 - 600) mg/kg, Mo (5,0 - 500) mg/kg, Ni (5,0 - 500) mg/kg, Pb (15,0 - 1000) mg/kg, Sb (20,0 - 200) mg/kg, Se (30,0 - 500) mg/kg, Sn (15,0 - 500) mg/kg, Ti (5,0 - 200) mg/kg, V (20,0 - 500) mg/kg, Zn (5,0 - 3000) mg/kg, Tl (40,0 - 500) mg/kg","parameters":[],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków, Zakres : As (10,0 - 200) mg/kg, Ba (10,0 - 3000) mg/kg, Cd (0,50 - 250) mg/kg, Co (5,0 - 500) mg/kg, Cr (5,0 - 1000) mg/kg, Cu (5,0 - 1000) mg/kg, Fe (10,0 - 750) mg/kg, Mn (10,0 - 600) mg/kg, Mo (5,0 - 500) mg/kg, Ni (5,0 - 500) mg/kg, Pb (15,0 - 1000) mg/kg, Sb (20,0 - 200) mg/kg, Se (30,0 - 500) mg/kg, Sn (15,0 - 500) mg/kg, Ti (5,0 - 200) mg/kg, V (20,0 - 500) mg/kg, Zn (5,0 - 3000) mg/kg, Tl (40,0 - 500) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","norm_bases":["PN-EN 16174:2012 Metoda B,","PN-EN ISO 11885:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość pierwiastków, Zakres : As (10,0 - 200) mg/kg, Ba (10,0 - 3000) mg/kg, Cd (0,50 - 250) mg/kg, Co (5,0 - 500) mg/kg, Cr (5,0 - 1000) mg/kg, Cu (5,0 - 1000) mg/kg, Fe (10,0 - 750) mg/kg, Mn (10,0 - 600) mg/kg, Mo (5,0 - 500) mg/kg, Ni (5,0 - 500) mg/kg, Pb (15,0 - 1000) mg/kg, Sb (20,0 - 200) mg/kg, Se (30,0 - 500) mg/kg, Sn (15,0 - 500) mg/kg, Ti (5,0 - 200) mg/kg, V (20,0 - 500) mg/kg, Zn (5,0 - 3000) mg/kg, Tl (40,0 - 500) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009 Gleba Zawartosc pierwiastkow, Zakres : As (10,0 - 200) mg/kg, Ba (10,0 - 3000) mg/kg, Cd (0,50 - 250) mg/kg, Co (5,0 - 500) mg/kg, Cr (5,0 - 1000) mg/kg, Cu (5,0 - 1000) mg/kg, Fe (10,0 - 750) mg/kg, Mn (10,0 - 600) mg/kg, Mo (5,0 - 500) mg/kg, Ni (5,0 - 500) mg/kg, Pb (15,0 - 1000) mg/kg, Sb (20,0 - 200) mg/kg, Se (30,0 - 500) mg/kg, Sn (15,0 - 500) mg/kg, Ti (5,0 - 200) mg/kg, V (20,0 - 500) mg/kg, Zn (5,0 - 3000) mg/kg, Tl (40,0 - 500) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of elements, Range : As (10,0 - 200) mg/kg, Ba (10,0 - 3000) mg/kg, Cd (0,50 - 250) mg/kg, Co (5,0 - 500) mg/kg, Cr (5,0 - 1000) mg/kg, Cu (5,0 - 1000) mg/kg, Fe (10,0 - 750) mg/kg, Mn (10,0 - 600) mg/kg, Mo (5,0 - 500) mg/kg, Ni (5,0 - 500) mg/kg, Pb (15,0 - 1000) mg/kg, Sb (20,0 - 200) mg/kg, Se (30,0 - 500) mg/kg, Sn (15,0 - 500) mg/kg, Ti (5,0 - 200) mg/kg, V (20,0 - 500) mg/kg, Zn (5,0 - 3000) mg/kg, Tl (40,0 - 500) mg/kg","search_en":"Soil Content of elements, Range : As (10,0 - 200) mg/kg, Ba (10,0 - 3000) mg/kg, Cd (0,50 - 250) mg/kg, Co (5,0 - 500) mg/kg, Cr (5,0 - 1000) mg/kg, Cu (5,0 - 1000) mg/kg, Fe (10,0 - 750) mg/kg, Mn (10,0 - 600) mg/kg, Mo (5,0 - 500) mg/kg, Ni (5,0 - 500) mg/kg, Pb (15,0 - 1000) mg/kg, Sb (20,0 - 200) mg/kg, Se (30,0 - 500) mg/kg, Sn (15,0 - 500) mg/kg, Ti (5,0 - 200) mg/kg, V (20,0 - 500) mg/kg, Zn (5,0 - 3000) mg/kg, Tl (40,0 - 500) mg/kg Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil","search_zh":"土壤 电感耦合等离子体发射光谱法（ICP-OES） PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","test_object_zh":"土壤","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b2134c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość benzyn (C6 - C12)","parameters":[{"name":"Zakres","range":"(10,0 - 1000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość benzyn (C6 - C12)\nZakres (10,0 - 1000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 16703:2011","norm_bases":["PN-ISO 16703:2011"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość benzyn (C6 - C12)\nZakres (10,0 - 1000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 16703:2011 Gleba Zawartosc benzyn (C6 - C12)\nZakres (10,0 - 1000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 16703:2011","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Petrol content (C6 - C12)","parameters_en":[{"name":"Range","range":"(10,0 - 1000) mg/kg"}],"search_en":"Soil Petrol content (C6 - C12) Gas chromatography with flame ionization detection (GC-FID) Range PN-ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(10,0 - 1000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a83bcf4af14b9c0e7b2134d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość olejów mineralnych (C12 - C35)","parameters":[{"name":"Zakres","range":"(10,0 - 5000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość olejów mineralnych (C12 - C35)\nZakres (10,0 - 5000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 16703:2011","norm_bases":["PN-ISO 16703:2011"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość olejów mineralnych (C12 - C35)\nZakres (10,0 - 5000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 16703:2011 Gleba Zawartosc olejow mineralnych (C12 - C35)\nZakres (10,0 - 5000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 16703:2011","categories":["environment","petro"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content (C12 - C35)","parameters_en":[{"name":"Range","range":"(10,0 - 5000) mg/kg"}],"search_en":"Soil Mineral oil content (C12 - C35) Gas chromatography with flame ionization detection (GC-FID) Range PN-ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(10,0 - 5000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a83bcf4af14b9c0e7b2134e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość olejów mineralnych (C10 - C40)","parameters":[{"name":"Zakres","range":"(10,0 - 5000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość olejów mineralnych (C10 - C40)\nZakres (10,0 - 5000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-ISO 16703:2011","norm_bases":["PN-ISO 16703:2011"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość olejów mineralnych (C10 - C40)\nZakres (10,0 - 5000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-ISO 16703:2011 Gleba Zawartosc olejow mineralnych (C10 - C40)\nZakres (10,0 - 5000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-ISO 16703:2011","categories":["environment","petro"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content (C10 - C40)","parameters_en":[{"name":"Range","range":"(10,0 - 5000) mg/kg"}],"search_en":"Soil Mineral oil content (C10 - C40) Gas chromatography with flame ionization detection (GC-FID) Range PN-ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(10,0 - 5000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a83bcf4af14b9c0e7b2134f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 - 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 - 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość siarki całkowitej\nZakres (0,10 - 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc siarki calkowitej\nZakres (0,10 - 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["environment","petro"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 - 2,00) %"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 - 2,00) %"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21350","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość węgla całkowitego, wodoru","parameters":[{"name":"wodór","range":"(3,0 - 10,0) %"},{"name":"węgiel","range":"(10,0 - 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego, wodoru\nZakres:\nwodór (3,0 - 10,0) %\nwęgiel (10,0 - 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość węgla całkowitego, wodoru\nZakres:\nwodór (3,0 - 10,0) %\nwęgiel (10,0 - 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc wegla calkowitego, wodoru\nZakres:\nwodor (3,0 - 10,0) %\nwegiel (10,0 - 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment","petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon, hydrogen content","parameters_en":[{"name":"hydrogen","range":"(3,0 - 10,0) %"},{"name":"carbon","range":"(10,0 - 80,0) %"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Total carbon, hydrogen content High-temperature combustion with IR detection hydrogen carbon PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 全碳与氢含量 高温燃烧红外检测法 氢 碳 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","parameters_zh":[{"name":"氢","range":"(3,0 - 10,0) %"},{"name":"碳","range":"(10,0 - 80,0) %"}],"test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210","methodology_zh":"全碳与氢含量"},{"_id":"6a83bcf4af14b9c0e7b21351","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,10 - 2,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chloru\nZakres (0,10 - 2,00) %\nMetoda miareczkowa","reference":"PN-ISO 587:2000","norm_bases":["PN-ISO 587:2000"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość chloru\nZakres (0,10 - 2,00) %\nMetoda miareczkowa PN-ISO 587:2000 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc chloru\nZakres (0,10 - 2,00) %\nMetoda miareczkowa PN-ISO 587:2000","categories":["environment","petro"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine content","parameters_en":[{"name":"Range","range":"(0,10 - 2,00) %"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Chlorine content Titrimetric method Range PN-ISO 587:2000","technique_en":"Titrimetric method","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","parameters_zh":[{"name":"范围","range":"(0,10 - 2,00) %"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 氯含量 滴定法 范围 PN-ISO 587:2000","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21352","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 - 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 - 80,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010","norm_bases":["CEN/TS 15414-1:2010"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość wilgoci całkowitej\nZakres (1,0 - 80,0) %\nMetoda wagowa CEN/TS 15414-1:2010 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc wilgoci calkowitej\nZakres (1,0 - 80,0) %\nMetoda wagowa CEN/TS 15414-1:2010","categories":["environment","petro"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 - 80,0) %"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Total moisture content Gravimetric method Range CEN/TS 15414-1:2010","technique_en":"Gravimetric method","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 - 80,0) %"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 全水分含量 重量法 范围 CEN/TS 15414-1:2010","technique_zh":"重量法","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21353","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 - 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 - 10,0) %\nMetoda wagowa","reference":"EKOLAB/LB/PB-210 wydanie 2 z dnia 12.09.2016 r.","norm_bases":["EKOLAB/LB/PB-210 wydanie 2 z dnia 12.09.2016 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość wilgoci w próbce analitycznej\nZakres (1,0 - 10,0) %\nMetoda wagowa EKOLAB/LB/PB-210 wydanie 2 z dnia 12.09.2016 r. Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc wilgoci w probce analitycznej\nZakres (1,0 - 10,0) %\nMetoda wagowa EKOLAB/LB/PB-210 wydanie 2 z dnia 12.09.2016 r.","categories":["environment","petro"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 - 10,0) %"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Moisture content in the analytical sample Gravimetric method Range EKOLAB/LB/PB-210 wydanie 2 z dnia 12.09.2016 r.","technique_en":"Gravimetric method","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 - 10,0) %"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 分析样品水分含量 重量法 范围 EKOLAB/LB/PB-210 wydanie 2 z dnia 12.09.2016 r.","technique_zh":"重量法","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21354","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,5 - 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,5 - 50,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość popiołu\nZakres (0,5 - 50,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc popiolu\nZakres (0,5 - 50,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["environment","petro"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,5 - 50,0) %"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Ash content Gravimetric method Range PN-EN ISO 21656:2021-08","technique_en":"Gravimetric method","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,5 - 50,0) %"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 灰分含量 重量法 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21355","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(15000 - 32000) J/g"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (15000 - 32000) J/g\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Ciepło spalania\nZakres (15000 - 32000) J/g\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Cieplo spalania\nZakres (15000 - 32000) J/g\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment","petro"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(15000 - 32000) J/g"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Gross calorific value Calorimetric method Range PN-EN ISO 21654:2021-12","technique_en":"Calorimetric method","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(15000 - 32000) J/g"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 高位发热量 量热法 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21356","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Wartość opałowa (z obliczeń) PN-EN ISO 21654:2021-12 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Wartosc opalowa (z obliczen) PN-EN ISO 21654:2021-12","categories":["environment","petro"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Net calorific value (calculated) PN-EN ISO 21654:2021-12","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 低位发热量（计算值） PN-EN ISO 21654:2021-12","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21357","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość pierwiastków","parameters":[{"name":"As","range":"(10,0 - 100) mg/kg"},{"name":"Cd","range":"(2,0 - 100) mg/kg"},{"name":"Co","range":"(2,0 - 100) mg/kg"},{"name":"Cr","range":"(2,0 - 100) mg/kg"},{"name":"Cu","range":"(5,0 - 100) mg/kg"},{"name":"Mn","range":"(2,0 - 100) mg/kg"},{"name":"Mo","range":"(5,0 - 100) mg/kg"},{"name":"Ni","range":"(2,0 - 100) mg/kg"},{"name":"Pb","range":"(10,0 - 100) mg/kg"},{"name":"Sb","range":"(10,0 - 100) mg/kg"},{"name":"Se","range":"(20,0 - 100) mg/kg"},{"name":"Tl","range":"(20,0 - 100) mg/kg"},{"name":"V","range":"(5,0 - 100) mg/kg"},{"name":"Zn","range":"(5,0 - 100) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nAs (10,0 - 100) mg/kg\nCd (2,0 - 100) mg/kg\nCo (2,0 - 100) mg/kg\nCr (2,0 - 100) mg/kg\nCu (5,0 - 100) mg/kg\nMn (2,0 - 100) mg/kg\nMo (5,0 - 100) mg/kg\nNi (2,0 - 100) mg/kg\nPb (10,0 - 100) mg/kg\nSb (10,0 - 100) mg/kg\nSe (20,0 - 100) mg/kg\nTl (20,0 - 100) mg/kg\nV (5,0 - 100) mg/kg\nZn (5,0 - 100) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 13657:2006 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 13657:2006","PN-EN ISO 11885:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość pierwiastków\nZakres:\nAs (10,0 - 100) mg/kg\nCd (2,0 - 100) mg/kg\nCo (2,0 - 100) mg/kg\nCr (2,0 - 100) mg/kg\nCu (5,0 - 100) mg/kg\nMn (2,0 - 100) mg/kg\nMo (5,0 - 100) mg/kg\nNi (2,0 - 100) mg/kg\nPb (10,0 - 100) mg/kg\nSb (10,0 - 100) mg/kg\nSe (20,0 - 100) mg/kg\nTl (20,0 - 100) mg/kg\nV (5,0 - 100) mg/kg\nZn (5,0 - 100) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 13657:2006 | PN-EN ISO 11885:2009 Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc pierwiastkow\nZakres:\nAs (10,0 - 100) mg/kg\nCd (2,0 - 100) mg/kg\nCo (2,0 - 100) mg/kg\nCr (2,0 - 100) mg/kg\nCu (5,0 - 100) mg/kg\nMn (2,0 - 100) mg/kg\nMo (5,0 - 100) mg/kg\nNi (2,0 - 100) mg/kg\nPb (10,0 - 100) mg/kg\nSb (10,0 - 100) mg/kg\nSe (20,0 - 100) mg/kg\nTl (20,0 - 100) mg/kg\nV (5,0 - 100) mg/kg\nZn (5,0 - 100) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 13657:2006 | PN-EN ISO 11885:2009","categories":["environment","petro"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"As","range":"(10,0 - 100) mg/kg"},{"name":"Cd","range":"(2,0 - 100) mg/kg"},{"name":"Co","range":"(2,0 - 100) mg/kg"},{"name":"Cr","range":"(2,0 - 100) mg/kg"},{"name":"Cu","range":"(5,0 - 100) mg/kg"},{"name":"Mn","range":"(2,0 - 100) mg/kg"},{"name":"Mo","range":"(5,0 - 100) mg/kg"},{"name":"Ni","range":"(2,0 - 100) mg/kg"},{"name":"Pb","range":"(10,0 - 100) mg/kg"},{"name":"Sb","range":"(10,0 - 100) mg/kg"},{"name":"Se","range":"(20,0 - 100) mg/kg"},{"name":"Tl","range":"(20,0 - 100) mg/kg"},{"name":"V","range":"(5,0 - 100) mg/kg"},{"name":"Zn","range":"(5,0 - 100) mg/kg"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) As Cd Co Cr Cu Mn Mo Ni Pb Sb Se Tl V Zn PN-EN 13657:2006 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"元素含量","parameters_zh":[{"name":"As","range":"(10,0 - 100) mg/kg"},{"name":"Cd","range":"(2,0 - 100) mg/kg"},{"name":"Co","range":"(2,0 - 100) mg/kg"},{"name":"Cr","range":"(2,0 - 100) mg/kg"},{"name":"Cu","range":"(5,0 - 100) mg/kg"},{"name":"Mn","range":"(2,0 - 100) mg/kg"},{"name":"Mo","range":"(5,0 - 100) mg/kg"},{"name":"Ni","range":"(2,0 - 100) mg/kg"},{"name":"Pb","range":"(10,0 - 100) mg/kg"},{"name":"Sb","range":"(10,0 - 100) mg/kg"},{"name":"Se","range":"(20,0 - 100) mg/kg"},{"name":"Tl","range":"(20,0 - 100) mg/kg"},{"name":"V","range":"(5,0 - 100) mg/kg"},{"name":"Zn","range":"(5,0 - 100) mg/kg"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 元素含量 电感耦合等离子体发射光谱法（ICP-OES） As Cd Co Cr Cu Mn Mo Ni Pb Sb Se Tl V Zn PN-EN 13657:2006 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21358","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,10 - 5,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,10 - 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","norm_bases":["PN-EN 13657:2006","PN-EN ISO 12846:2012+ Ap1:2016-07E"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Paliwa stałe − odpady palne o) (paliwo alternatywne): kod 191210 Zawartość rtęci\nZakres (0,10 - 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E Paliwa stale − odpady palne o) (paliwo alternatywne): kod 191210 Zawartosc rteci\nZakres (0,10 - 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","categories":["environment","petro"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,10 - 5,0) mg/kg"}],"search_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210 Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Solid fuels − combustible waste o) (alternative fuel): code 191210","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,10 - 5,0) mg/kg"}],"search_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"固体燃料 － 可燃废物 o)（替代燃料）：代码 191210"},{"_id":"6a83bcf4af14b9c0e7b21359","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Zawartość pierwiastków","parameters":[{"name":"Cr","range":"(5,0 - 5000) mg/kg"},{"name":"Zn","range":"(5,0 - 5000) mg/kg"},{"name":"Cd","range":"(5,0 - 500) mg/kg"},{"name":"Cu","range":"(5,0 - 5000) mg/kg"},{"name":"Pb","range":"(25 - 5000) mg/kg"},{"name":"Ni","range":"(5,0 - 500) mg/kg"},{"name":"P","range":"(0,050 - 10,0) %"},{"name":"Mg","range":"(0,010 - 5,00) %"},{"name":"Ca","range":"(0,010 - 5,00) %"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCr (5,0 - 5000) mg/kg\nZn (5,0 - 5000) mg/kg\nCd (5,0 - 500) mg/kg\nCu (5,0 - 5000) mg/kg\nPb (25 - 5000) mg/kg\nNi (5,0 - 500) mg/kg\nP (0,050 - 10,0) %\nMg (0,010 - 5,00) %\nCa (0,010 - 5,00) %\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","norm_bases":["PN-EN 16174:2012 Metoda B,","PN-EN ISO 11885:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 Zawartość pierwiastków\nZakres:\nCr (5,0 - 5000) mg/kg\nZn (5,0 - 5000) mg/kg\nCd (5,0 - 500) mg/kg\nCu (5,0 - 5000) mg/kg\nPb (25 - 5000) mg/kg\nNi (5,0 - 500) mg/kg\nP (0,050 - 10,0) %\nMg (0,010 - 5,00) %\nCa (0,010 - 5,00) %\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009 Osady sciekowe, Odpady O) kod: 19 08 05 Zawartosc pierwiastkow\nZakres:\nCr (5,0 - 5000) mg/kg\nZn (5,0 - 5000) mg/kg\nCd (5,0 - 500) mg/kg\nCu (5,0 - 5000) mg/kg\nPb (25 - 5000) mg/kg\nNi (5,0 - 500) mg/kg\nP (0,050 - 10,0) %\nMg (0,010 - 5,00) %\nCa (0,010 - 5,00) %\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","categories":["water","environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Cr","range":"(5,0 - 5000) mg/kg"},{"name":"Zn","range":"(5,0 - 5000) mg/kg"},{"name":"Cd","range":"(5,0 - 500) mg/kg"},{"name":"Cu","range":"(5,0 - 5000) mg/kg"},{"name":"Pb","range":"(25 - 5000) mg/kg"},{"name":"Ni","range":"(5,0 - 500) mg/kg"},{"name":"P","range":"(0,050 - 10,0) %"},{"name":"Mg","range":"(0,010 - 5,00) %"},{"name":"Ca","range":"(0,010 - 5,00) %"}],"search_en":"Sewage sludge, Waste O) code: 19 08 05 Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Cr Zn Cd Cu Pb Ni P Mg Ca PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","methodology_zh":"元素含量","parameters_zh":[{"name":"Cr","range":"(5,0 - 5000) mg/kg"},{"name":"Zn","range":"(5,0 - 5000) mg/kg"},{"name":"Cd","range":"(5,0 - 500) mg/kg"},{"name":"Cu","range":"(5,0 - 5000) mg/kg"},{"name":"Pb","range":"(25 - 5000) mg/kg"},{"name":"Ni","range":"(5,0 - 500) mg/kg"},{"name":"P","range":"(0,050 - 10,0) %"},{"name":"Mg","range":"(0,010 - 5,00) %"},{"name":"Ca","range":"(0,010 - 5,00) %"}],"search_zh":"元素含量 电感耦合等离子体发射光谱法（ICP-OES） Cr Zn Cd Cu Pb Ni P Mg Ca PN-EN 16174:2012 Metoda B, | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b2135a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,10 - 30,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,10 - 30,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012 +Ap1:2016-07E","norm_bases":["PN-EN 16174:2012 Metoda B,","PN-EN ISO 12846:2012 +Ap1:2016-07E"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 Zawartość rtęci\nZakres (0,10 - 30,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012 +Ap1:2016-07E Osady sciekowe, Odpady O) kod: 19 08 05 Zawartosc rteci\nZakres (0,10 - 30,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012 +Ap1:2016-07E","categories":["water","environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,10 - 30,0) mg/kg"}],"search_en":"Sewage sludge, Waste O) code: 19 08 05 Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012 +Ap1:2016-07E","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,10 - 30,0) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 16174:2012 Metoda B, | PN-EN ISO 12846:2012 +Ap1:2016-07E","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a83bcf4af14b9c0e7b2135b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Strata prażenia, sucha masa","parameters":[{"name":"Zakres","range":"(0,1 - 99) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata prażenia, sucha masa\nZakres (0,1 - 99) %\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 Strata prażenia, sucha masa\nZakres (0,1 - 99) %\nMetoda wagowa PN-EN 12879:2004 Osady sciekowe, Odpady O) kod: 19 08 05 Strata prazenia, sucha masa\nZakres (0,1 - 99) %\nMetoda wagowa PN-EN 12879:2004","categories":["water","environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition, dry matter","parameters_en":[{"name":"Range","range":"(0,1 - 99) %"}],"search_en":"Sewage sludge, Waste O) code: 19 08 05 Loss on ignition, dry matter Gravimetric method Range PN-EN 12879:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,1 - 99) %"}],"search_zh":"重量法 范围 PN-EN 12879:2004","technique_zh":"重量法"},{"_id":"6a83bcf4af14b9c0e7b2135c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Sucha pozostałość, zawartość wody","parameters":[{"name":"Zakres","range":"(0,1 - 99) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość, zawartość wody\nZakres (0,1 - 99) %\nMetoda wagowa","reference":"PN EN 12880:2004","norm_bases":["PN EN 12880:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 Sucha pozostałość, zawartość wody\nZakres (0,1 - 99) %\nMetoda wagowa PN EN 12880:2004 Osady sciekowe, Odpady O) kod: 19 08 05 Sucha pozostalosc, zawartosc wody\nZakres (0,1 - 99) %\nMetoda wagowa PN EN 12880:2004","categories":["water","environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue, water content","parameters_en":[{"name":"Range","range":"(0,1 - 99) %"}],"search_en":"Sewage sludge, Waste O) code: 19 08 05 Dry residue, water content Gravimetric method Range PN EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,1 - 99) %"}],"search_zh":"重量法 范围 PN EN 12880:2004","technique_zh":"重量法"},{"_id":"6a83bcf4af14b9c0e7b2135d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 11,0\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 pH\nZakres 2,0 - 11,0\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe, Odpady O) kod: 19 08 05 pH\nZakres 2,0 - 11,0\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water","environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 11,0"}],"search_en":"Sewage sludge, Waste O) code: 19 08 05 pH Potentiometric method Range PN-EN 12176:2004","technique_en":"Potentiometric method","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 11,0"}],"search_zh":"pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法"},{"_id":"6a83bcf4af14b9c0e7b2135e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,1 - 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,1 - 10) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 Zawartość azotu Kjeldahla\nZakres (0,1 - 10) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe, Odpady O) kod: 19 08 05 Zawartosc azotu Kjeldahla\nZakres (0,1 - 10) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water","environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,1 - 10) %"}],"search_en":"Sewage sludge, Waste O) code: 19 08 05 Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,1 - 10) %"}],"search_zh":"凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a83bcf4af14b9c0e7b2135f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 19 08 05","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 - 3,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 - 3,0) %\nMetoda miareczkowa","reference":"EKOLAB/LB/PB-54 wydanie 2 z dnia 07.03.2011 r.","norm_bases":["EKOLAB/LB/PB-54 wydanie 2 z dnia 07.03.2011 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie komunalnych osadów ściekowych (Dz. U. 2015, poz. 257); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 19 08 05 Zawartość azotu amonowego\nZakres (0,10 - 3,0) %\nMetoda miareczkowa EKOLAB/LB/PB-54 wydanie 2 z dnia 07.03.2011 r. Osady sciekowe, Odpady O) kod: 19 08 05 Zawartosc azotu amonowego\nZakres (0,10 - 3,0) %\nMetoda miareczkowa EKOLAB/LB/PB-54 wydanie 2 z dnia 07.03.2011 r.","categories":["water","environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 - 3,0) %"}],"search_en":"Sewage sludge, Waste O) code: 19 08 05 Ammonium nitrogen content Titrimetric method Range EKOLAB/LB/PB-54 wydanie 2 z dnia 07.03.2011 r.","technique_en":"Titrimetric method","test_object_en":"Sewage sludge, Waste O) code: 19 08 05","parameters_zh":[{"name":"范围","range":"(0,10 - 3,0) %"}],"search_zh":"氨氮含量 滴定法 范围 EKOLAB/LB/PB-54 wydanie 2 z dnia 07.03.2011 r.","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a83bcf4af14b9c0e7b21360","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 14, 19 12 12, 19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(1000 - 30000) J/g"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (1000 - 30000) J/g\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 14, 19 12 12, 19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Ciepło spalania\nZakres (1000 - 30000) J/g\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Odpady O) kod: 19 08 14, 19 12 12, 19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Cieplo spalania\nZakres (1000 - 30000) J/g\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(1000 - 30000) J/g"}],"search_en":"Gross calorific value Calorimetric method Range PN-EN ISO 21654:2021-12","technique_en":"Calorimetric method","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(1000 - 30000) J/g"}],"search_zh":"高位发热量 量热法 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法"},{"_id":"6a83bcf4af14b9c0e7b21361","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 14, 19 12 12, 19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,01 - 2,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,01 - 2,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 14, 19 12 12, 19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Zawartość siarki całkowitej\nZakres (0,01 - 2,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15408:2011 Odpady O) kod: 19 08 14, 19 12 12, 19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Zawartosc siarki calkowitej\nZakres (0,01 - 2,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15408:2011","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,01 - 2,0) %"}],"search_en":"Total sulfur content High-temperature combustion with IR detection Range PN-EN 15408:2011","technique_en":"High-temperature combustion with IR detection","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 - 2,0) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 PN-EN 15408:2011","technique_zh":"高温燃烧红外检测法"},{"_id":"6a83bcf4af14b9c0e7b21362","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99","methodology":"Strata prażenia","parameters":[{"name":"Zakres","range":"(0,10 - 99) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata prażenia\nZakres (0,10 - 99) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Strata prażenia\nZakres (0,10 - 99) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Strata prazenia\nZakres (0,10 - 99) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(0,10 - 99) %"}],"search_en":"Loss on ignition Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 - 99) %"}],"search_zh":"烧失量 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"烧失量"},{"_id":"6a83bcf4af14b9c0e7b21363","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99","methodology":"Ogólny węgiel organiczny","parameters":[{"name":"Zakres","range":"(0,1 - 95) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Ogólny węgiel organiczny\nZakres (0,1 - 95) %\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-186 wydanie 1 z dnia 03.04.2012 r.","norm_bases":["EKOLAB/LB/PB-186 wydanie 1 z dnia 03.04.2012 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Ogólny węgiel organiczny\nZakres (0,1 - 95) %\nMetoda spektrofotometryczna EKOLAB/LB/PB-186 wydanie 1 z dnia 03.04.2012 r. Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Ogolny wegiel organiczny\nZakres (0,1 - 95) %\nMetoda spektrofotometryczna EKOLAB/LB/PB-186 wydanie 1 z dnia 03.04.2012 r.","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon","parameters_en":[{"name":"Range","range":"(0,1 - 95) %"}],"search_en":"Total organic carbon Spectrophotometric method Range EKOLAB/LB/PB-186 wydanie 1 z dnia 03.04.2012 r.","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(0,1 - 95) %"}],"search_zh":"分光光度法 范围 EKOLAB/LB/PB-186 wydanie 1 z dnia 03.04.2012 r.","technique_zh":"分光光度法"},{"_id":"6a83bcf4af14b9c0e7b21364","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99","methodology":"Zawartość suchej masy","parameters":[{"name":"Zakres","range":"(1,0 - 20) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy\nZakres (1,0 - 20) %\nMetoda wagowa","reference":"PN-EN 14346:2011 Metoda A","norm_bases":["PN-EN 14346:2011 Metoda A"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Zawartość suchej masy\nZakres (1,0 - 20) %\nMetoda wagowa PN-EN 14346:2011 Metoda A Odpady O) kod: 10 10 09*, 15 02 02*, 17 05 03*, 19 01 11*, 19 02 05*, 19 03 06* 19 05 03, 19 05 99, 19 08 14, 19 12 12, 17 05 05*,19 08 12 20 01 01, 20 01 02, 20 01 10, 20 01 11, 20 01 39, 20 01 99, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Zawartosc suchej masy\nZakres (1,0 - 20) %\nMetoda wagowa PN-EN 14346:2011 Metoda A","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content","parameters_en":[{"name":"Range","range":"(1,0 - 20) %"}],"search_en":"Dry matter content Gravimetric method Range PN-EN 14346:2011 Metoda A","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 - 20) %"}],"search_zh":"干物质含量 重量法 范围 PN-EN 14346:2011 Metoda A","technique_zh":"重量法","methodology_zh":"干物质含量"},{"_id":"6a83bcf4af14b9c0e7b21365","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08,","methodology":"Zawartość suchej masy","parameters":[{"name":"Zakres","range":"(1,0 - 20) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy\nZakres (1,0 - 20) %\nMetoda wagowa","reference":"PN-EN 14346:2011 Metoda A","norm_bases":["PN-EN 14346:2011 Metoda A"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Zawartość suchej masy\nZakres (1,0 - 20) %\nMetoda wagowa PN-EN 14346:2011 Metoda A Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Zawartosc suchej masy\nZakres (1,0 - 20) %\nMetoda wagowa PN-EN 14346:2011 Metoda A","categories":["environment"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter content","parameters_en":[{"name":"Range","range":"(1,0 - 20) %"}],"search_en":"Dry matter content Gravimetric method Range PN-EN 14346:2011 Metoda A","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 - 20) %"}],"search_zh":"干物质含量 重量法 范围 PN-EN 14346:2011 Metoda A","technique_zh":"重量法","methodology_zh":"干物质含量"},{"_id":"6a83bcf4af14b9c0e7b21366","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08,","methodology":"Wilgotność całkowita","parameters":[{"name":"Zakres","range":"(1 - 95) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wilgotność całkowita\nZakres (1 - 95) %\nMetoda wagowa","reference":"PN-93/Z-15008/02","norm_bases":["PN-93/Z-15008/02"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Wilgotność całkowita\nZakres (1 - 95) %\nMetoda wagowa PN-93/Z-15008/02 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Wilgotnosc calkowita\nZakres (1 - 95) %\nMetoda wagowa PN-93/Z-15008/02","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1 - 95) %"}],"search_en":"Total moisture content Gravimetric method Range PN-93/Z-15008/02","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1 - 95) %"}],"search_zh":"重量法 范围 PN-93/Z-15008/02","technique_zh":"重量法"},{"_id":"6a83bcf4af14b9c0e7b21367","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08,","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,10 - 5,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,10 - 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","norm_bases":["PN-EN 13657:2006","PN-EN ISO 12846:2012+ Ap1:2016-07E"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Zawartość rtęci\nZakres (0,10 - 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Zawartosc rteci\nZakres (0,10 - 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,10 - 5,0) mg/kg"}],"search_en":"Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,10 - 5,0) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 13657:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a83bcf4af14b9c0e7b21368","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08,","methodology":"Zawartość pierwiastków","parameters":[{"name":"Ag","range":"(10,0 - 100) mg/kg"},{"name":"As","range":"(10,0 - 100) mg/kg"},{"name":"B","range":"(10,0 - 100) mg/kg"},{"name":"Ba","range":"(10,0 - 100) mg/kg"},{"name":"Cd","range":"(1,0 - 20) mg/kg"},{"name":"Co","range":"(2,0 - 20) mg/kg"},{"name":"Cr","range":"(2,0 - 100) mg/kg"},{"name":"Cu","range":"(5,0 - 500) mg/kg"},{"name":"Fe","range":"(10,0 - 500) mg/kg"},{"name":"Mn","range":"(2,0 - 100) mg/kg"},{"name":"Mo","range":"(10,0 - 100) mg/kg"},{"name":"Ni","range":"(2,0 - 100) mg/kg"},{"name":"Pb","range":"(20,0 - 100) mg/kg"},{"name":"Sb","range":"(10,0 - 100) mg/kg"},{"name":"Se","range":"(20,0 - 100) mg/kg"},{"name":"Sn","range":"(20,0 - 100) mg/kg"},{"name":"Ti","range":"(5,0 - 100) mg/kg"},{"name":"V","range":"(10,0 - 100) mg/kg"},{"name":"Zn","range":"(5,0 - 500) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nAg (10,0 - 100) mg/kg\nAs (10,0 - 100) mg/kg\nB (10,0 - 100) mg/kg\nBa (10,0 - 100) mg/kg\nCd (1,0 - 20) mg/kg\nCo (2,0 - 20) mg/kg\nCr (2,0 - 100) mg/kg\nCu (5,0 - 500) mg/kg\nFe (10,0 - 500) mg/kg\nMn (2,0 - 100) mg/kg\nMo (10,0 - 100) mg/kg\nNi (2,0 - 100) mg/kg\nPb (20,0 - 100) mg/kg\nSb (10,0 - 100) mg/kg\nSe (20,0 - 100) mg/kg\nSn (20,0 - 100) mg/kg\nTi (5,0 - 100) mg/kg\nV (10,0 - 100) mg/kg\nZn (5,0 - 500) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"EKOLAB/LB/PB-68 wydanie 3 z dnia 03.04.2012 r.","norm_bases":["EKOLAB/LB/PB-68 wydanie 3 z dnia 03.04.2012 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Zawartość pierwiastków\nZakres:\nAg (10,0 - 100) mg/kg\nAs (10,0 - 100) mg/kg\nB (10,0 - 100) mg/kg\nBa (10,0 - 100) mg/kg\nCd (1,0 - 20) mg/kg\nCo (2,0 - 20) mg/kg\nCr (2,0 - 100) mg/kg\nCu (5,0 - 500) mg/kg\nFe (10,0 - 500) mg/kg\nMn (2,0 - 100) mg/kg\nMo (10,0 - 100) mg/kg\nNi (2,0 - 100) mg/kg\nPb (20,0 - 100) mg/kg\nSb (10,0 - 100) mg/kg\nSe (20,0 - 100) mg/kg\nSn (20,0 - 100) mg/kg\nTi (5,0 - 100) mg/kg\nV (10,0 - 100) mg/kg\nZn (5,0 - 500) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) EKOLAB/LB/PB-68 wydanie 3 z dnia 03.04.2012 r. Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13 10 01 01, 10 01 05, 10 01 80, 10 09 03, 10 09 08, 10 09 10, 10 10 09* , 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 01 99, 16 03 04, 16 03 80, 16 11 04, 17 01 06 17 01 82, 17 02 03, 17 03 80 17 05 03*, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99 19 08 01, 19 08 02, 19 08 14, 19 09 02, 19 12 09 19 12 12, 20 01 99, 20 03 03 20 03 99, 17 02 01, 17 02 04* 17 05 04, 17 05 05*, 17 05 06 17 05 07, 17 05 08, Zawartosc pierwiastkow\nZakres:\nAg (10,0 - 100) mg/kg\nAs (10,0 - 100) mg/kg\nB (10,0 - 100) mg/kg\nBa (10,0 - 100) mg/kg\nCd (1,0 - 20) mg/kg\nCo (2,0 - 20) mg/kg\nCr (2,0 - 100) mg/kg\nCu (5,0 - 500) mg/kg\nFe (10,0 - 500) mg/kg\nMn (2,0 - 100) mg/kg\nMo (10,0 - 100) mg/kg\nNi (2,0 - 100) mg/kg\nPb (20,0 - 100) mg/kg\nSb (10,0 - 100) mg/kg\nSe (20,0 - 100) mg/kg\nSn (20,0 - 100) mg/kg\nTi (5,0 - 100) mg/kg\nV (10,0 - 100) mg/kg\nZn (5,0 - 500) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) EKOLAB/LB/PB-68 wydanie 3 z dnia 03.04.2012 r.","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Ag","range":"(10,0 - 100) mg/kg"},{"name":"As","range":"(10,0 - 100) mg/kg"},{"name":"B","range":"(10,0 - 100) mg/kg"},{"name":"Ba","range":"(10,0 - 100) mg/kg"},{"name":"Cd","range":"(1,0 - 20) mg/kg"},{"name":"Co","range":"(2,0 - 20) mg/kg"},{"name":"Cr","range":"(2,0 - 100) mg/kg"},{"name":"Cu","range":"(5,0 - 500) mg/kg"},{"name":"Fe","range":"(10,0 - 500) mg/kg"},{"name":"Mn","range":"(2,0 - 100) mg/kg"},{"name":"Mo","range":"(10,0 - 100) mg/kg"},{"name":"Ni","range":"(2,0 - 100) mg/kg"},{"name":"Pb","range":"(20,0 - 100) mg/kg"},{"name":"Sb","range":"(10,0 - 100) mg/kg"},{"name":"Se","range":"(20,0 - 100) mg/kg"},{"name":"Sn","range":"(20,0 - 100) mg/kg"},{"name":"Ti","range":"(5,0 - 100) mg/kg"},{"name":"V","range":"(10,0 - 100) mg/kg"},{"name":"Zn","range":"(5,0 - 500) mg/kg"}],"search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Ag As B Ba Cd Co Cr Cu Fe Mn Mo Ni Pb Sb Se Sn Ti V Zn EKOLAB/LB/PB-68 wydanie 3 z dnia 03.04.2012 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","parameters_zh":[{"name":"Ag","range":"(10,0 - 100) mg/kg"},{"name":"As","range":"(10,0 - 100) mg/kg"},{"name":"B","range":"(10,0 - 100) mg/kg"},{"name":"Ba","range":"(10,0 - 100) mg/kg"},{"name":"Cd","range":"(1,0 - 20) mg/kg"},{"name":"Co","range":"(2,0 - 20) mg/kg"},{"name":"Cr","range":"(2,0 - 100) mg/kg"},{"name":"Cu","range":"(5,0 - 500) mg/kg"},{"name":"Fe","range":"(10,0 - 500) mg/kg"},{"name":"Mn","range":"(2,0 - 100) mg/kg"},{"name":"Mo","range":"(10,0 - 100) mg/kg"},{"name":"Ni","range":"(2,0 - 100) mg/kg"},{"name":"Pb","range":"(20,0 - 100) mg/kg"},{"name":"Sb","range":"(10,0 - 100) mg/kg"},{"name":"Se","range":"(20,0 - 100) mg/kg"},{"name":"Sn","range":"(20,0 - 100) mg/kg"},{"name":"Ti","range":"(5,0 - 100) mg/kg"},{"name":"V","range":"(10,0 - 100) mg/kg"},{"name":"Zn","range":"(5,0 - 500) mg/kg"}],"search_zh":"元素含量 电感耦合等离子体发射光谱法（ICP-OES） Ag As B Ba Cd Co Cr Cu Fe Mn Mo Ni Pb Sb Se Sn Ti V Zn EKOLAB/LB/PB-68 wydanie 3 z dnia 03.04.2012 r.","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b21369","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,010 - 2,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,010 - 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 12846:2012+ Ap1:2016-07E"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość rtęci\nZakres (0,010 - 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-4:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc rteci\nZakres (0,010 - 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-4:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,010 - 2,00) mg/kg"}],"search_en":"Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 12457-4:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,010 - 2,00) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 12457-4:2006 | PN-EN ISO 12846:2012+ Ap1:2016-07E","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a83bcf4af14b9c0e7b2136a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość pierwiastków","parameters":[{"name":"Sb","range":"(0,50 - 100) mg/kg"},{"name":"As","range":"(0,20 - 50) mg/kg"},{"name":"Cr","range":"(0,40 - 100 ) mg/kg"},{"name":"Zn","range":"(0,10 - 200) mg/kg"},{"name":"Cd","range":"(0,10 - 50) mg/kg"},{"name":"Cu","range":"(0,50 - 200) mg/kg"},{"name":"Mo","range":"(1,0 - 100) mg/kg"},{"name":"Ni","range":"(0,40 - 100) mg/kg"},{"name":"Pb","range":"(3,0 - 100) mg/kg"},{"name":"Se","range":"(0,50 - 100) mg/kg"},{"name":"Ba","range":"(0,10 - 300) mg/kg"}],"technique":"Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nSb (0,50 - 100) mg/kg\nAs (0,20 - 50) mg/kg\nCr (0,40 - 100 ) mg/kg\nZn (0,10 - 200) mg/kg\nCd (0,10 - 50) mg/kg\nCu (0,50 - 200) mg/kg\nMo (1,0 - 100) mg/kg\nNi (0,40 - 100) mg/kg\nPb (3,0 - 100) mg/kg\nSe (0,50 - 100) mg/kg\nBa (0,10 - 300) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 11885:2009"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość pierwiastków\nZakres:\nSb (0,50 - 100) mg/kg\nAs (0,20 - 50) mg/kg\nCr (0,40 - 100 ) mg/kg\nZn (0,10 - 200) mg/kg\nCd (0,10 - 50) mg/kg\nCu (0,50 - 200) mg/kg\nMo (1,0 - 100) mg/kg\nNi (0,40 - 100) mg/kg\nPb (3,0 - 100) mg/kg\nSe (0,50 - 100) mg/kg\nBa (0,10 - 300) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc pierwiastkow\nZakres:\nSb (0,50 - 100) mg/kg\nAs (0,20 - 50) mg/kg\nCr (0,40 - 100 ) mg/kg\nZn (0,10 - 200) mg/kg\nCd (0,10 - 50) mg/kg\nCu (0,50 - 200) mg/kg\nMo (1,0 - 100) mg/kg\nNi (0,40 - 100) mg/kg\nPb (3,0 - 100) mg/kg\nSe (0,50 - 100) mg/kg\nBa (0,10 - 300) mg/kg\nMetoda atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Sb","range":"(0,50 - 100) mg/kg"},{"name":"As","range":"(0,20 - 50) mg/kg"},{"name":"Cr","range":"(0,40 - 100 ) mg/kg"},{"name":"Zn","range":"(0,10 - 200) mg/kg"},{"name":"Cd","range":"(0,10 - 50) mg/kg"},{"name":"Cu","range":"(0,50 - 200) mg/kg"},{"name":"Mo","range":"(1,0 - 100) mg/kg"},{"name":"Ni","range":"(0,40 - 100) mg/kg"},{"name":"Pb","range":"(3,0 - 100) mg/kg"},{"name":"Se","range":"(0,50 - 100) mg/kg"},{"name":"Ba","range":"(0,10 - 300) mg/kg"}],"search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Sb As Cr Zn Cd Cu Mo Ni Pb Se Ba PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","parameters_zh":[{"name":"Sb","range":"(0,50 - 100) mg/kg"},{"name":"As","range":"(0,20 - 50) mg/kg"},{"name":"Cr","range":"(0,40 - 100 ) mg/kg"},{"name":"Zn","range":"(0,10 - 200) mg/kg"},{"name":"Cd","range":"(0,10 - 50) mg/kg"},{"name":"Cu","range":"(0,50 - 200) mg/kg"},{"name":"Mo","range":"(1,0 - 100) mg/kg"},{"name":"Ni","range":"(0,40 - 100) mg/kg"},{"name":"Pb","range":"(3,0 - 100) mg/kg"},{"name":"Se","range":"(0,50 - 100) mg/kg"},{"name":"Ba","range":"(0,10 - 300) mg/kg"}],"search_zh":"元素含量 电感耦合等离子体发射光谱法（ICP-OES） Sb As Cr Zn Cd Cu Mo Ni Pb Se Ba PN-EN 12457-4:2006 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b2136b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 11,0\nMetoda potencjometryczna","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10523:2012"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 pH\nZakres 2,0 - 11,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 pH\nZakres 2,0 - 11,0\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","categories":["environment"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 11,0"}],"search_en":"pH Potentiometric method Range PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 11,0"}],"search_zh":"pH 值 电位法 范围 PN-EN 12457-4:2006 | PN-EN ISO 10523:2012","technique_zh":"电位法"},{"_id":"6a83bcf4af14b9c0e7b2136c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość stałych związków rozpuszczonych","parameters":[{"name":"Zakres","range":"(1,0 - 350) g/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość stałych związków rozpuszczonych\nZakres (1,0 - 350) g/kg\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-EN 15216:2022-03","norm_bases":["PN-EN 12457-4:2006","PN-EN 15216:2022-03"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość stałych związków rozpuszczonych\nZakres (1,0 - 350) g/kg\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc stalych zwiazkow rozpuszczonych\nZakres (1,0 - 350) g/kg\nMetoda wagowa PN-EN 12457-4:2006 | PN-EN 15216:2022-03","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of total dissolved solids","parameters_en":[{"name":"Range","range":"(1,0 - 350) g/kg"}],"search_en":"Content of total dissolved solids Gravimetric method Range PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 - 350) g/kg"}],"search_zh":"重量法 范围 PN-EN 12457-4:2006 | PN-EN 15216:2022-03","technique_zh":"重量法"},{"_id":"6a83bcf4af14b9c0e7b2136d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość siarczanów","parameters":[{"name":"Zakres","range":"(300 - 50000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość siarczanów\nZakres (300 - 50000) mg/kg\nMetoda wagowa","reference":"PN-EN 12457-4:2006 | PN-ISO 9280:2002","norm_bases":["PN-EN 12457-4:2006","PN-ISO 9280:2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość siarczanów\nZakres (300 - 50000) mg/kg\nMetoda wagowa PN-EN 12457-4:2006 | PN-ISO 9280:2002 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc siarczanow\nZakres (300 - 50000) mg/kg\nMetoda wagowa PN-EN 12457-4:2006 | PN-ISO 9280:2002","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate content","parameters_en":[{"name":"Range","range":"(300 - 50000) mg/kg"}],"search_en":"Sulfate content Gravimetric method Range PN-EN 12457-4:2006 | PN-ISO 9280:2002","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(300 - 50000) mg/kg"}],"search_zh":"硫酸盐含量 重量法 范围 PN-EN 12457-4:2006 | PN-ISO 9280:2002","technique_zh":"重量法","methodology_zh":"硫酸盐含量"},{"_id":"6a83bcf4af14b9c0e7b2136e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(50 - 25000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość chlorków\nZakres (50 - 25000) mg/kg\nMetoda miareczkowa","reference":"PN-EN 12457-4:2006 | PN-ISO 9297:1994","norm_bases":["PN-EN 12457-4:2006","PN-ISO 9297:1994"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość chlorków\nZakres (50 - 25000) mg/kg\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-ISO 9297:1994 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc chlorkow\nZakres (50 - 25000) mg/kg\nMetoda miareczkowa PN-EN 12457-4:2006 | PN-ISO 9297:1994","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(50 - 25000) mg/kg"}],"search_en":"Chloride content Titrimetric method Range PN-EN 12457-4:2006 | PN-ISO 9297:1994","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(50 - 25000) mg/kg"}],"search_zh":"氯化物含量 滴定法 范围 PN-EN 12457-4:2006 | PN-ISO 9297:1994","technique_zh":"滴定法","methodology_zh":"氯化物含量"},{"_id":"6a83bcf4af14b9c0e7b2136f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość fluorków","parameters":[{"name":"Zakres","range":"(5,0 - 1000) mg/kg"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość fluorków\nZakres (5,0 - 1000) mg/kg\nMetoda potencjometryczna","reference":"PN-EN 12457-4:2006 | PN-78/C-04588/03","norm_bases":["PN-EN 12457-4:2006","PN-78/C-04588/03"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość fluorków\nZakres (5,0 - 1000) mg/kg\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-78/C-04588/03 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc fluorkow\nZakres (5,0 - 1000) mg/kg\nMetoda potencjometryczna PN-EN 12457-4:2006 | PN-78/C-04588/03","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride content","parameters_en":[{"name":"Range","range":"(5,0 - 1000) mg/kg"}],"search_en":"Fluoride content Potentiometric method Range PN-EN 12457-4:2006 | PN-78/C-04588/03","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"(5,0 - 1000) mg/kg"}],"search_zh":"氟化物含量 电位法 范围 PN-EN 12457-4:2006 | PN-78/C-04588/03","technique_zh":"电位法","methodology_zh":"氟化物含量"},{"_id":"6a83bcf4af14b9c0e7b21370","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość rozpuszczonego węgla organicznego","parameters":[{"name":"Zakres","range":"(50 - 15000) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość rozpuszczonego węgla organicznego\nZakres (50 - 15000) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 EKOLAB/LB/PB-26 wydanie 3 z dnia 07.03.2011 r. wg testu MERCK nr 1.14878.0001","norm_bases":["PN-EN 12457-4:2006 EKOLAB/LB/PB-26 wydanie 3 z dnia 07.03.2011 r. wg testu MERCK nr 1.14878.0001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość rozpuszczonego węgla organicznego\nZakres (50 - 15000) mg/kg\nMetoda spektrofotometryczna PN-EN 12457-4:2006 EKOLAB/LB/PB-26 wydanie 3 z dnia 07.03.2011 r. wg testu MERCK nr 1.14878.0001 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc rozpuszczonego wegla organicznego\nZakres (50 - 15000) mg/kg\nMetoda spektrofotometryczna PN-EN 12457-4:2006 EKOLAB/LB/PB-26 wydanie 3 z dnia 07.03.2011 r. wg testu MERCK nr 1.14878.0001","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon content","parameters_en":[{"name":"Range","range":"(50 - 15000) mg/kg"}],"search_en":"Dissolved organic carbon content Spectrophotometric method Range PN-EN 12457-4:2006 EKOLAB/LB/PB-26 wydanie 3 z dnia 07.03.2011 r. wg testu MERCK nr 1.14878.0001","technique_en":"Spectrophotometric method","parameters_zh":[{"name":"范围","range":"(50 - 15000) mg/kg"}],"search_zh":"分光光度法 范围 PN-EN 12457-4:2006 EKOLAB/LB/PB-26 wydanie 3 z dnia 07.03.2011 r. wg testu MERCK nr 1.14878.0001","technique_zh":"分光光度法"},{"_id":"6a83bcf4af14b9c0e7b21371","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08","methodology":"Zawartość rozpuszczonego węgla organicznego","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość rozpuszczonego węgla organicznego\nZakres (10 - 5000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 12457-4:2006 | PN-EN 1484:1999","norm_bases":["PN-EN 12457-4:2006","PN-EN 1484:1999"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego w Rozporządzeniu Ministra Gospodarki z dnia 16 lipca 2015r. w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. 2015, poz.1277); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartość rozpuszczonego węgla organicznego\nZakres (10 - 5000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 12457-4:2006 | PN-EN 1484:1999 Odpady O) kod: 02 02 04, 03 03 07, 04 02 09, 07 02 13, 10 01 01 10 01 05, 10 01 80, 10 09 03 10 09 08, 10 09 10, 10 10 09* 10 10 12, 10 12 08, 10 13 81, 12 01 05, 15 02 02*, 15 02 03, 16 03 04, 16 11 04, 17 01 82, 17 02 03, 17 03 80, 17 05 04, 17 06 04, 17 09 04, 19 01 07* 19 01 11*, 19 02 05*, 19 02 06, 19 03 04, 19 03 05, 19 03 06* 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 19 12 12, 17 05 04, 17 05 06, 17 05 08 Zawartosc rozpuszczonego wegla organicznego\nZakres (10 - 5000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 12457-4:2006 | PN-EN 1484:1999","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon content","parameters_en":[{"name":"Range","range":"(10 - 5000) mg/kg"}],"search_en":"Dissolved organic carbon content High-temperature combustion with IR detection Range PN-EN 12457-4:2006 | PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/kg"}],"search_zh":"高温燃烧红外检测法 范围 PN-EN 12457-4:2006 | PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法"},{"_id":"6a83bcf4af14b9c0e7b21372","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Odpady O) kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99,","methodology":"Aktywność oddechowa (AT4)","parameters":[{"name":"Zakres","range":"(3 - 60) mg/g"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"computed":[],"activity":"Aktywność oddechowa (AT4)\nZakres (3 - 60) mg/g\nMetoda manometryczna","reference":"EKOLAB/LB/PB-200 wydanie 2 z dnia 22.04.2016 r.","norm_bases":["EKOLAB/LB/PB-200 wydanie 2 z dnia 22.04.2016 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":"Rozporządzenie Ministra Klimatu i Środowiska z dnia 28 grudnia 2022 r. w sprawie mechaniczno-biologicznego przetwarzania niesegregowanych (zmieszanych) odpadów komunalnych (Dz.U. 2023 poz. 56); O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, Aktywność oddechowa (AT4)\nZakres (3 - 60) mg/g\nMetoda manometryczna EKOLAB/LB/PB-200 wydanie 2 z dnia 22.04.2016 r. Odpady O) kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, Aktywnosc oddechowa (AT4)\nZakres (3 - 60) mg/g\nMetoda manometryczna EKOLAB/LB/PB-200 wydanie 2 z dnia 22.04.2016 r.","categories":["environment","metrology"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Respiration activity (AT4)","parameters_en":[{"name":"Range","range":"(3 - 60) mg/g"}],"search_en":"Respiration activity (AT4) Manometric method Range EKOLAB/LB/PB-200 wydanie 2 z dnia 22.04.2016 r.","technique_en":"Manometric method","parameters_zh":[{"name":"范围","range":"(3 - 60) mg/g"}],"search_zh":"呼吸活性（AT4） 压力计法 范围 EKOLAB/LB/PB-200 wydanie 2 z dnia 22.04.2016 r.","technique_zh":"压力计法","methodology_zh":"呼吸活性（AT4）"},{"_id":"6a83bcf4af14b9c0e7b21373","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze sprężone","methodology":"Zawartość oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,08 - 3,2) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Zawartość oleju mineralnego\nZakres (0,08 - 3,2) mg w próbce\nMetoda spektrometrii w podczerwieni (IR)","reference":"EKOLAB/LB/PB-190 wydanie 1 z dnia 03.04.2012 r.","norm_bases":["EKOLAB/LB/PB-190 wydanie 1 z dnia 03.04.2012 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – powietrze sprężone Zawartość oleju mineralnego\nZakres (0,08 - 3,2) mg w próbce\nMetoda spektrometrii w podczerwieni (IR) EKOLAB/LB/PB-190 wydanie 1 z dnia 03.04.2012 r. Srodowisko ogolne – powietrze sprezone Zawartosc oleju mineralnego\nZakres (0,08 - 3,2) mg w probce\nMetoda spektrometrii w podczerwieni (IR) EKOLAB/LB/PB-190 wydanie 1 z dnia 03.04.2012 r.","categories":["environment","petro"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content","parameters_en":[{"name":"Range","range":"(0,08 - 3,2) mg w próbce"}],"search_en":"Mineral oil content Infrared spectrometry method (IR) Range EKOLAB/LB/PB-190 wydanie 1 z dnia 03.04.2012 r.","technique_en":"Infrared spectrometry method (IR)","parameters_zh":[{"name":"范围","range":"(0,08 - 3,2) mg w próbce"}],"search_zh":"矿物油含量 红外光谱法（IR） 范围 EKOLAB/LB/PB-190 wydanie 1 z dnia 03.04.2012 r.","technique_zh":"红外光谱法（IR）","methodology_zh":"矿物油含量"},{"_id":"6a83bcf4af14b9c0e7b21374","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze sprężone pobierane na rurki z sorbentem","methodology":"Zawartość oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,08 - 3,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość oleju mineralnego\nZakres (0,08 - 3,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EKOLAB/LB/PB-209 wydanie 2 z dnia 31.01.2017 r.","norm_bases":["EKOLAB/LB/PB-209 wydanie 2 z dnia 31.01.2017 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – powietrze sprężone pobierane na rurki z sorbentem Zawartość oleju mineralnego\nZakres (0,08 - 3,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EKOLAB/LB/PB-209 wydanie 2 z dnia 31.01.2017 r. Srodowisko ogolne – powietrze sprezone pobierane na rurki z sorbentem Zawartosc oleju mineralnego\nZakres (0,08 - 3,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EKOLAB/LB/PB-209 wydanie 2 z dnia 31.01.2017 r.","categories":["environment","petro"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil content","parameters_en":[{"name":"Range","range":"(0,08 - 3,2) mg w próbce"}],"search_en":"Mineral oil content Gas chromatography with flame ionization detection (GC-FID) Range EKOLAB/LB/PB-209 wydanie 2 z dnia 31.01.2017 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"范围","range":"(0,08 - 3,2) mg w próbce"}],"search_zh":"矿物油含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 EKOLAB/LB/PB-209 wydanie 2 z dnia 31.01.2017 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油含量"},{"_id":"6a83bcf4af14b9c0e7b21375","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Krzemionka krystaliczna – kwarc, krystobalit","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(3,0 - 400) μg w próbce"}],"technique":"Metoda spektrofotometrii w podczerwieni (FT-IR)","techniques":["Metoda spektrofotometrii w podczerwieni (FT-IR)"],"computed":[],"activity":"Krzemionka krystaliczna – kwarc, krystobalit\nZakres:\nfrakcja respirabilna\nZakres (3,0 - 400) μg w próbce\nMetoda spektrofotometrii w podczerwieni (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74)","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74)"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Krzemionka krystaliczna – kwarc, krystobalit\nZakres:\nfrakcja respirabilna\nZakres (3,0 - 400) μg w próbce\nMetoda spektrofotometrii w podczerwieni (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) Srodowisko pracy - probki powietrza pobrane na filtry Krzemionka krystaliczna – kwarc, krystobalit\nZakres:\nfrakcja respirabilna\nZakres (3,0 - 400) μg w probce\nMetoda spektrofotometrii w podczerwieni (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74)","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystalline silica – quartz, cristobalite","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(3,0 - 400) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Crystalline silica – quartz, cristobalite Infrared spectrophotometry method (FT-IR) respirable fraction Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74)","technique_en":"Infrared spectrophotometry method (FT-IR)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(3,0 - 400) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 呼吸性组分 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74)","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21376","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość oleju mineralnego, wysokorafinowanego z wyłączeniem cieczy obróbkowych","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,08 - 3,2) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Zawartość oleju mineralnego, wysokorafinowanego z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,08 - 3,2) mg w próbce\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-Z-04108-05:2006","norm_bases":["PN-Z-04108-05:2006"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość oleju mineralnego, wysokorafinowanego z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,08 - 3,2) mg w próbce\nMetoda spektrometrii w podczerwieni (IR) PN-Z-04108-05:2006 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc oleju mineralnego, wysokorafinowanego z wylaczeniem cieczy obrobkowych\nZakres:\nfrakcja wdychalna\nZakres (0,08 - 3,2) mg w probce\nMetoda spektrometrii w podczerwieni (IR) PN-Z-04108-05:2006","categories":["environment","petro"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of mineral oil, highly refined excluding metalworking fluids","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,08 - 3,2) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of mineral oil, highly refined excluding metalworking fluids Infrared spectrometry method (IR) inhalable fraction Range PN-Z-04108-05:2006","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,08 - 3,2) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 红外光谱法（IR） 可吸入组分 范围 PN-Z-04108-05:2006","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"红外光谱法（IR）"},{"_id":"6a83bcf4af14b9c0e7b21377","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość srebra","parameters":[{"name":"frakcja wdychalna"},{"name":"związki nierozpuszczalne w przeliczeniu na Ag"},{"name":"Zakres","range":"(2,5 - 125) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość srebra\nZakres:\nfrakcja wdychalna\nzwiązki nierozpuszczalne w przeliczeniu na Ag\nZakres (2,5 - 125) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość srebra\nZakres:\nfrakcja wdychalna\nzwiązki nierozpuszczalne w przeliczeniu na Ag\nZakres (2,5 - 125) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc srebra\nZakres:\nfrakcja wdychalna\nzwiazki nierozpuszczalne w przeliczeniu na Ag\nZakres (2,5 - 125) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Silver content","parameters_en":[{"name":"inhalable fraction"},{"name":"insoluble compounds expressed as Ag"},{"name":"Range","range":"(2,5 - 125) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Silver content Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction insoluble compounds expressed as Ag Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"związki nierozpuszczalne w przeliczeniu na Ag"},{"name":"范围","range":"(2,5 - 125) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 银含量 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"银含量","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b21378","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość glinu metalicznego, glin proszek (niestabilizowany)","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość glinu metalicznego, glin proszek (niestabilizowany)\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość glinu metalicznego, glin proszek (niestabilizowany)\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc glinu metalicznego, glin proszek (niestabilizowany)\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["materials","environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metallic aluminium content, aluminium powder (unstabilised)","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air samples collected on filters Metallic aluminium content, aluminium powder (unstabilised) inhalable fraction respirable fraction Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 可吸入组分 呼吸性组分 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21379","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tritlenku glinu w przeliczeniu na","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tritlenku glinu w przeliczeniu na","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tritlenku glinu w przeliczeniu na Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tritlenku glinu w przeliczeniu na Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of aluminium trioxide expressed as","search_en":"Workplace environment - air samples collected on filters Content of aluminium trioxide expressed as Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","search_zh":"工作场所环境 — 用滤膜采集的空气样品 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b2137a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Al","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":null,"techniques":[],"computed":[],"activity":"Al\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Al\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Al\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Al","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air samples collected on filters Al inhalable fraction respirable fraction Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 Al 可吸入组分 呼吸性组分 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","methodology_zh":"Al","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b2137b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość wodorotlenku glinu w przeliczeniu na Al","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(8,5 - 1000) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość wodorotlenku glinu w przeliczeniu na Al\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (8,5 - 1000) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość wodorotlenku glinu w przeliczeniu na Al\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (8,5 - 1000) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc wodorotlenku glinu w przeliczeniu na Al\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (8,5 - 1000) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium hydroxide content expressed as Al","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(8,5 - 1000) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Aluminium hydroxide content expressed as Al Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction respirable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(8,5 - 1000) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 呼吸性组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b2137c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,5 - 125) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,5 - 125) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,5 - 125) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc arsenu i jego zwiazkow nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,5 - 125) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of arsenic and its inorganic compounds calculated as As","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,5 - 125) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of arsenic and its inorganic compounds calculated as As Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,5 - 125) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b2137d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość berylu i jego związków nieorganicznych w przeliczeniu na Be","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,1 - 12) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość berylu i jego związków nieorganicznych w przeliczeniu na Be\nZakres:\nfrakcja wdychalna\nZakres (0,1 - 12) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość berylu i jego związków nieorganicznych w przeliczeniu na Be\nZakres:\nfrakcja wdychalna\nZakres (0,1 - 12) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc berylu i jego zwiazkow nieorganicznych w przeliczeniu na Be\nZakres:\nfrakcja wdychalna\nZakres (0,1 - 12) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of beryllium and its inorganic compounds calculated as Be","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,1 - 12) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of beryllium and its inorganic compounds calculated as Be Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,1 - 12) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b2137e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA","parameters":[{"name":"(benzo(a)antracen"},{"name":"Zakres","range":"(0,0003 - 0,5) μg w próbce"},{"name":"chryzen (0,00005 - 0,05) μg w próbce benzo(b)fluoranten (0,0005 - 0,2) μg w próbce benzo(k)fluoranten (0,0009 - 0,2) μg w próbce benzo(a)piren (0,003 - 2) μg w próbce benzo(ghi)perylen (0,00005 - 0,05) μg w próbce indeno","range":"(123cd)piren"},{"name":"(0,001 - 0,5) μg w próbce dibenzo(a,h)antracen (0,015 - 25) μg w próbce antracen (0,00003 - 0,05) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjna (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjna (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA\nZakres:\n(benzo(a)antracen\nZakres (0,0003 - 0,5) μg w próbce\nchryzen (0,00005 - 0,05) μg w próbce benzo(b)fluoranten (0,0005 - 0,2) μg w próbce benzo(k)fluoranten (0,0009 - 0,2) μg w próbce benzo(a)piren (0,003 - 2) μg w próbce benzo(ghi)perylen (0,00005 - 0,05) μg w próbce indeno (123cd)piren\n(0,001 - 0,5) μg w próbce dibenzo(a,h)antracen (0,015 - 25) μg w próbce antracen (0,00003 - 0,05) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjna (HPLC-FLD)","reference":"PN-Z-04240-5:2006","norm_bases":["PN-Z-04240-5:2006"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry - próbki powietrza pobrane na rurki z sorbentem Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA\nZakres:\n(benzo(a)antracen\nZakres (0,0003 - 0,5) μg w próbce\nchryzen (0,00005 - 0,05) μg w próbce benzo(b)fluoranten (0,0005 - 0,2) μg w próbce benzo(k)fluoranten (0,0009 - 0,2) μg w próbce benzo(a)piren (0,003 - 2) μg w próbce benzo(ghi)perylen (0,00005 - 0,05) μg w próbce indeno (123cd)piren\n(0,001 - 0,5) μg w próbce dibenzo(a,h)antracen (0,015 - 25) μg w próbce antracen (0,00003 - 0,05) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjna (HPLC-FLD) PN-Z-04240-5:2006 Srodowisko pracy - probki powietrza pobrane na filtry - probki powietrza pobrane na rurki z sorbentem Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA) jako suma iloczynow stezen i wspolczynnikow rakotworczosci 9 rakotworczych WWA\nZakres:\n(benzo(a)antracen\nZakres (0,0003 - 0,5) μg w probce\nchryzen (0,00005 - 0,05) μg w probce benzo(b)fluoranten (0,0005 - 0,2) μg w probce benzo(k)fluoranten (0,0009 - 0,2) μg w probce benzo(a)piren (0,003 - 2) μg w probce benzo(ghi)perylen (0,00005 - 0,05) μg w probce indeno (123cd)piren\n(0,001 - 0,5) μg w probce dibenzo(a,h)antracen (0,015 - 25) μg w probce antracen (0,00003 - 0,05) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-5:2006","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of polycyclic aromatic hydrocarbons (PAH) as the sum of products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs","parameters_en":[{"name":"(benzo(a)anthracene"},{"name":"Range","range":"(0,0003 - 0,5) μg w próbce"},{"name":"chrysene (0,00005 - 0,05) μg in the sample benzo(b)fluoranthene (0,0005 - 0,2) μg in the sample benzo(k)fluoranthene (0,0009 - 0,2) μg in the sample benzo(a)pyrene (0,003 - 2) μg in the sample benzo(ghi)perylene (0,00005 - 0,05) μg in the sample indeno","range":"(123cd)piren"},{"name":"(0,001 - 0,5) μg in the sample dibenzo(a,h)anthracene (0,015 - 25) μg in the sample anthracene (0,00003 - 0,05) μg in the sample"}],"search_en":"Workplace environment - air samples collected on filters - air samples collected on sorbent tubes Content of polycyclic aromatic hydrocarbons (PAH) as the sum of products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs High-performance liquid chromatography with fluorescence detection (HPLC-FLD) (benzo(a)anthracene Range chrysene (0,00005 - 0,05) μg in the sample benzo(b)fluoranthene (0,0005 - 0,2) μg in the sample benzo(k)fluoranthene (0,0009 - 0,2) μg in the sample benzo(a)pyrene (0,003 - 2) μg in the sample benzo(ghi)perylene (0,00005 - 0,05) μg in the sample indeno (0,001 - 0,5) μg in the sample dibenzo(a,h)anthracene (0,015 - 25) μg in the sample anthracene (0,00003 - 0,05) μg in the sample PN-Z-04240-5:2006","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment - air samples collected on filters - air samples collected on sorbent tubes","parameters_zh":[{"name":"(benzo(a)antracen"},{"name":"范围","range":"(0,0003 - 0,5) μg w próbce"},{"name":"chryzen (0,00005 - 0,05) μg w próbce benzo(b)fluoranten (0,0005 - 0,2) μg w próbce benzo(k)fluoranten (0,0009 - 0,2) μg w próbce benzo(a)piren (0,003 - 2) μg w próbce benzo(ghi)perylen (0,00005 - 0,05) μg w próbce indeno","range":"(123cd)piren"},{"name":"(0,001 - 0,5) μg w próbce dibenzo(a,h)antracen (0,015 - 25) μg w próbce antracen (0,00003 - 0,05) μg w próbce"}],"search_zh":"范围 PN-Z-04240-5:2006"},{"_id":"6a83bcf4af14b9c0e7b2137f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,1125 - 6,0) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość chlorowodoru\nZakres (0,1125 - 6,0) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","norm_bases":["Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość chlorowodoru\nZakres (0,1125 - 6,0) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc chlorowodoru\nZakres (0,1125 - 6,0) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride content","parameters_en":[{"name":"Range","range":"(0,1125 - 6,0) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Hydrogen chloride content Ion chromatography with conductometric detection (IC-CD) Range Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,1125 - 6,0) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氯化氢含量 离子色谱-电导检测法（IC-CD） 范围 Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"氯化氢含量"},{"_id":"6a83bcf4af14b9c0e7b21380","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość kwasu azotowego","parameters":[{"name":"Zakres","range":"(0,02925 - 1,6) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość kwasu azotowego\nZakres (0,02925 - 1,6) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","norm_bases":["Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość kwasu azotowego\nZakres (0,02925 - 1,6) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc kwasu azotowego\nZakres (0,02925 - 1,6) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitric acid content","parameters_en":[{"name":"Range","range":"(0,02925 - 1,6) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Nitric acid content Ion chromatography with conductometric detection (IC-CD) Range Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,02925 - 1,6) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 离子色谱-电导检测法（IC-CD） 范围 Metodyka NIOSH Manual of Analytical Methods, Method 7907, Issue 1, Maj 2014","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21381","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość fluorowodoru","parameters":[{"name":"Zakres","range":"(0,012 - 0,72) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość fluorowodoru\nZakres (0,012 - 0,72) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Metodyka NIOSH Manual of Analytical Methods, Method 7906, Issue 2, Maj 2014","norm_bases":["Metodyka NIOSH Manual of Analytical Methods, Method 7906, Issue 2, Maj 2014"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość fluorowodoru\nZakres (0,012 - 0,72) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Metodyka NIOSH Manual of Analytical Methods, Method 7906, Issue 2, Maj 2014 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc fluorowodoru\nZakres (0,012 - 0,72) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Metodyka NIOSH Manual of Analytical Methods, Method 7906, Issue 2, Maj 2014","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride content","parameters_en":[{"name":"Range","range":"(0,012 - 0,72) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Hydrogen fluoride content Ion chromatography with conductometric detection (IC-CD) Range Metodyka NIOSH Manual of Analytical Methods, Method 7906, Issue 2, Maj 2014","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,012 - 0,72) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氟化氢含量 离子色谱-电导检测法（IC-CD） 范围 Metodyka NIOSH Manual of Analytical Methods, Method 7906, Issue 2, Maj 2014","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"氟化氢含量"},{"_id":"6a83bcf4af14b9c0e7b21382","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość frakcji torakalnej kwasu siarkowego","parameters":[{"name":"Zakres","range":"(0,002 - 0,50) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) badane cechy/metoda","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) badane cechy/metoda"],"computed":[],"activity":"Zawartość frakcji torakalnej kwasu siarkowego\nZakres (0,002 - 0,50) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) badane cechy/metoda","reference":"Podstawy Metody Oceny Środowiska Pracy 2012, nr 1(71)","norm_bases":["Podstawy Metody Oceny Środowiska Pracy 2012, nr 1(71)"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość frakcji torakalnej kwasu siarkowego\nZakres (0,002 - 0,50) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) badane cechy/metoda Podstawy Metody Oceny Środowiska Pracy 2012, nr 1(71) Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc frakcji torakalnej kwasu siarkowego\nZakres (0,002 - 0,50) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) badane cechy/metoda Podstawy Metody Oceny Srodowiska Pracy 2012, nr 1(71)","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Thoracic fraction content of sulphuric acid","parameters_en":[{"name":"Range","range":"(0,002 - 0,50) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Thoracic fraction content of sulphuric acid Ion chromatography with conductometric detection (IC-CD) tested characteristics/method Range Podstawy Metody Oceny Środowiska Pracy 2012, nr 1(71)","technique_en":"Ion chromatography with conductometric detection (IC-CD) tested characteristics/method","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,002 - 0,50) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Podstawy Metody Oceny Środowiska Pracy 2012, nr 1(71)","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21383","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość baru i jego związków rozpuszczalnych w przeliczeniu na Ba","parameters":[{"name":"Zakres","range":"(0,3 - 1000) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość baru i jego związków rozpuszczalnych w przeliczeniu na Ba\nZakres (0,3 - 1000) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość baru i jego związków rozpuszczalnych w przeliczeniu na Ba\nZakres (0,3 - 1000) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc baru i jego zwiazkow rozpuszczalnych w przeliczeniu na Ba\nZakres (0,3 - 1000) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of barium and its soluble compounds calculated as Ba","parameters_en":[{"name":"Range","range":"(0,3 - 1000) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of barium and its soluble compounds calculated as Ba Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,3 - 1000) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21384","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość kadmu i jego związków nieorganicznych w przeliczeniu na Cd","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,3 - 125) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość kadmu i jego związków nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,3 - 125) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość kadmu i jego związków nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,3 - 125) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc kadmu i jego zwiazkow nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,3 - 125) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of cadmium and its inorganic compounds calculated as Cd","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,3 - 125) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of cadmium and its inorganic compounds calculated as Cd inhalable fraction respirable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,3 - 125) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 可吸入组分 呼吸性组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21385","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co","parameters":[{"name":"Zakres","range":"(1 - 120) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres (1 - 120) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość kobaltu i jego związków nieorganicznych w przeliczeniu na Co\nZakres (1 - 120) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc kobaltu i jego zwiazkow nieorganicznych w przeliczeniu na Co\nZakres (1 - 120) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of cobalt and its inorganic compounds calculated as Co","parameters_en":[{"name":"Range","range":"(1 - 120) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of cobalt and its inorganic compounds calculated as Co Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(1 - 120) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21386","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr","parameters":[{"name":"Zakres","range":"(1 - 120) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (1 - 120) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (1 - 120) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc chromu metalicznego, zwiazkow chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (1 - 120) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["materials","environment"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metallic chromium, chromium compounds: (chromium (II), chromium (III), chromium (VI) – expressed as Cr","parameters_en":[{"name":"Range","range":"(1 - 120) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of metallic chromium, chromium compounds: (chromium (II), chromium (III), chromium (VI) – expressed as Cr Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(1 - 120) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21387","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(5 - 250) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (5 - 250) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (5 - 250) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc miedzi i jej zwiazkow nieorganicznych w przeliczeniu na Cu\nZakres (5 - 250) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of copper and its inorganic compounds calculated as Cu","parameters_en":[{"name":"Range","range":"(5 - 250) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of copper and its inorganic compounds calculated as Cu Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(5 - 250) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 铜及其无机化合物含量（以 Cu 计） 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"铜及其无机化合物含量（以 Cu 计）"},{"_id":"6a83bcf4af14b9c0e7b21388","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tlenków żelaza w przeliczeniu na Fe:","parameters":[{"name":"Tlenek żelaza(III)"},{"name":"Tlenek żelaza(II)"},{"name":"Tetratlenek triżelaza"},{"name":"frakcja respirabilna"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(10 - 7500) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tlenków żelaza w przeliczeniu na Fe:\nZakres:\nTlenek żelaza(III)\nTlenek żelaza(II)\nTetratlenek triżelaza\nfrakcja respirabilna\nfrakcja wdychalna\nZakres (10 - 7500) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tlenków żelaza w przeliczeniu na Fe:\nZakres:\nTlenek żelaza(III)\nTlenek żelaza(II)\nTetratlenek triżelaza\nfrakcja respirabilna\nfrakcja wdychalna\nZakres (10 - 7500) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tlenkow zelaza w przeliczeniu na Fe:\nZakres:\nTlenek zelaza(III)\nTlenek zelaza(II)\nTetratlenek trizelaza\nfrakcja respirabilna\nfrakcja wdychalna\nZakres (10 - 7500) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Tlenek żelaza(III)"},{"name":"Iron(II) oxide"},{"name":"Triiron tetraoxide"},{"name":"respirable fraction"},{"name":"inhalable fraction"},{"name":"Range","range":"(10 - 7500) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Iron(II) oxide Triiron tetraoxide respirable fraction inhalable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"Tlenek żelaza(III)"},{"name":"Tlenek żelaza(II)"},{"name":"四氧化三铁"},{"name":"呼吸性组分"},{"name":"可吸入组分"},{"name":"范围","range":"(10 - 7500) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 四氧化三铁 呼吸性组分 可吸入组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21389","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(3 - 2500) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (3 - 2500) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (3 - 2500) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (3 - 2500) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of manganese and its inorganic compounds calculated as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(3 - 2500) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of manganese and its inorganic compounds calculated as Mn inhalable fraction respirable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(3 - 2500) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 锰及其无机化合物含量（以 Mn 计） 可吸入组分 呼吸性组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"锰及其无机化合物含量（以 Mn 计）"},{"_id":"6a83bcf4af14b9c0e7b2138a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość molibdenu i jego związków w przeliczeniu na Mo","parameters":[{"name":"Zakres","range":"(3 - 120) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość molibdenu i jego związków w przeliczeniu na Mo\nZakres (3 - 120) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość molibdenu i jego związków w przeliczeniu na Mo\nZakres (3 - 120) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc molibdenu i jego zwiazkow w przeliczeniu na Mo\nZakres (3 - 120) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of molybdenum and its compounds calculated as Mo","parameters_en":[{"name":"Range","range":"(3 - 120) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of molybdenum and its compounds calculated as Mo Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(3 - 120) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b2138b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość związków niklu, w przeliczeniu na Ni","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,50 - 120) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość związków niklu, w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,50 - 120) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość związków niklu, w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,50 - 120) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc zwiazkow niklu, w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,50 - 120) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of nickel compounds, expressed as Ni","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,50 - 120) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of nickel compounds, expressed as Ni inhalable fraction respirable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,50 - 120) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 可吸入组分 呼吸性组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b2138c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,50 - 400) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość niklu metalicznego\nZakres (0,50 - 400) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość niklu metalicznego\nZakres (0,50 - 400) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc niklu metalicznego\nZakres (0,50 - 400) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["materials","environment"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metallic nickel content","parameters_en":[{"name":"Range","range":"(0,50 - 400) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Metallic nickel content Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,50 - 400) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 金属镍含量 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"金属镍含量"},{"_id":"6a83bcf4af14b9c0e7b2138d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(7 - 120) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (7 - 120) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (7 - 120) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc olowiu i jego zwiazkow nieorganicznych – w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (7 - 120) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(7 - 120) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters inhalable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(7 - 120) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 可吸入组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b2138e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość antymonu i jego związków nieorganicznych z wyjątkiem stibanu w przeliczeniu na Sb","parameters":[{"name":"Zakres","range":"(4 - 250) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość antymonu i jego związków nieorganicznych z wyjątkiem stibanu w przeliczeniu na Sb\nZakres (4 - 250) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość antymonu i jego związków nieorganicznych z wyjątkiem stibanu w przeliczeniu na Sb\nZakres (4 - 250) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc antymonu i jego zwiazkow nieorganicznych z wyjatkiem stibanu w przeliczeniu na Sb\nZakres (4 - 250) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(4 - 250) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(4 - 250) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b2138f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość selenu i jego związków z wyjątkiem selanu w przeliczeniu na Se","parameters":[{"name":"Zakres","range":"(15 - 120) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość selenu i jego związków z wyjątkiem selanu w przeliczeniu na Se\nZakres (15 - 120) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość selenu i jego związków z wyjątkiem selanu w przeliczeniu na Se\nZakres (15 - 120) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc selenu i jego zwiazkow z wyjatkiem selanu w przeliczeniu na Se\nZakres (15 - 120) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of selenium and its compounds excluding selane calculated as Se","parameters_en":[{"name":"Range","range":"(15 - 120) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of selenium and its compounds excluding selane calculated as Se Inductively coupled plasma optical emission spectrometry (ICP-OES) Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(15 - 120) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b21390","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(10 - 250) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (10 - 250) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (10 - 250) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc cyny i jej zwiazkow nieorganicznych z wyjatkiem stannanu w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (10 - 250) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of tin and its inorganic compounds excluding stannane calculated as Sn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(10 - 250) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of tin and its inorganic compounds excluding stannane calculated as Sn inhalable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(10 - 250) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 可吸入组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21391","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tytanu i jego związków w przeliczeniu na Ti","parameters":[{"name":"Zakres","range":"(1,5 - 50) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tytanu i jego związków w przeliczeniu na Ti\nZakres (1,5 - 50) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tytanu i jego związków w przeliczeniu na Ti\nZakres (1,5 - 50) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tytanu i jego zwiazkow w przeliczeniu na Ti\nZakres (1,5 - 50) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of titanium and its compounds expressed as Ti","parameters_en":[{"name":"Range","range":"(1,5 - 50) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of titanium and its compounds expressed as Ti Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(1,5 - 50) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21392","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tlenku cynku w przeliczeniu na Zn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(10 - 1250) μg w próbce"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (10 - 1250) μg w próbce","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (10 - 1250) μg w próbce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (10 - 1250) μg w probce Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Zinc oxide content calculated as Zn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(10 - 1250) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Zinc oxide content calculated as Zn inhalable fraction Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(10 - 1250) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氧化锌含量（以 Zn 计） 可吸入组分 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"氧化锌含量（以 Zn 计）"},{"_id":"6a83bcf4af14b9c0e7b21393","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość cyrkonu i jego związków w przeliczeniu na Zr","parameters":[{"name":"Zakres","range":"(2,5 - 50) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość cyrkonu i jego związków w przeliczeniu na Zr\nZakres (2,5 - 50) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość cyrkonu i jego związków w przeliczeniu na Zr\nZakres (2,5 - 50) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc cyrkonu i jego zwiazkow w przeliczeniu na Zr\nZakres (2,5 - 50) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of zirconium and its compounds calculated as Zr","parameters_en":[{"name":"Range","range":"(2,5 - 50) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of zirconium and its compounds calculated as Zr Inductively coupled plasma optical emission spectrometry (ICP-OES) Range Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(2,5 - 50) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b21394","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tlenku cynku w przeliczeniu na Zn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(10 - 1250) μg w próbce"},{"name":"Zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu"},{"name":"Zakres","range":"(5 - 250) μg w próbce"},{"name":"Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(3 - 1250) μg w próbce"},{"name":"Zawartość tlenków żelaza w przeliczeniu na Fe: Tlenek żelaza(III) Tlenek żelaza(II) Tetratlenek triżelaza"},{"name":"frakcja respirabilna"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(10 - 1250) μg w próbce"},{"name":"Zawartość związków niklu w przeliczeniu na Ni"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,50 - 120) μg w próbce"},{"name":"Zawartość niklu metalicznego"},{"name":"Zakres","range":"(0,50 - 400) μg w próbce"},{"name":"Zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr"},{"name":"Zakres","range":"(1 - 125) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (10 - 1250) μg w próbce\nZawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (5 - 250) μg w próbce\nZawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (3 - 1250) μg w próbce\nZawartość tlenków żelaza w przeliczeniu na Fe: Tlenek żelaza(III) Tlenek żelaza(II) Tetratlenek triżelaza\nfrakcja respirabilna\nfrakcja wdychalna\nZakres (10 - 1250) μg w próbce\nZawartość związków niklu w przeliczeniu na Ni\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,50 - 120) μg w próbce\nZawartość niklu metalicznego\nZakres (0,50 - 400) μg w próbce\nZawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (1 - 125) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"ISO 15202-3:2004-11","norm_bases":["ISO 15202-3:2004-11"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (10 - 1250) μg w próbce\nZawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres (5 - 250) μg w próbce\nZawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (3 - 1250) μg w próbce\nZawartość tlenków żelaza w przeliczeniu na Fe: Tlenek żelaza(III) Tlenek żelaza(II) Tetratlenek triżelaza\nfrakcja respirabilna\nfrakcja wdychalna\nZakres (10 - 1250) μg w próbce\nZawartość związków niklu w przeliczeniu na Ni\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,50 - 120) μg w próbce\nZawartość niklu metalicznego\nZakres (0,50 - 400) μg w próbce\nZawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (1 - 125) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) ISO 15202-3:2004-11 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (10 - 1250) μg w probce\nZawartosc miedzi i jej zwiazkow nieorganicznych w przeliczeniu na Cu\nZakres (5 - 250) μg w probce\nZawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (3 - 1250) μg w probce\nZawartosc tlenkow zelaza w przeliczeniu na Fe: Tlenek zelaza(III) Tlenek zelaza(II) Tetratlenek trizelaza\nfrakcja respirabilna\nfrakcja wdychalna\nZakres (10 - 1250) μg w probce\nZawartosc zwiazkow niklu w przeliczeniu na Ni\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,50 - 120) μg w probce\nZawartosc niklu metalicznego\nZakres (0,50 - 400) μg w probce\nZawartosc chromu metalicznego, zwiazkow chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres (1 - 125) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) ISO 15202-3:2004-11","categories":["materials","environment"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Zinc oxide content calculated as Zn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(10 - 1250) μg w próbce"},{"name":"Content of copper and its inorganic compounds calculated as Cu"},{"name":"Range","range":"(5 - 250) μg w próbce"},{"name":"Content of manganese and its inorganic compounds calculated as Mn"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(3 - 1250) μg w próbce"},{"name":"Content of iron oxides calculated as Fe: Iron(III) oxide Iron(II) oxide Triiron tetraoxide"},{"name":"respirable fraction"},{"name":"inhalable fraction"},{"name":"Range","range":"(10 - 1250) μg w próbce"},{"name":"Content of nickel compounds calculated as Ni"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,50 - 120) μg w próbce"},{"name":"Metallic nickel content"},{"name":"Range","range":"(0,50 - 400) μg w próbce"},{"name":"Content of metallic chromium, chromium compounds: (chromium (II), chromium (III), chromium (VI) – expressed as Cr"},{"name":"Range","range":"(1 - 125) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Zinc oxide content calculated as Zn Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction Range Content of copper and its inorganic compounds calculated as Cu Range Content of manganese and its inorganic compounds calculated as Mn inhalable fraction respirable fraction Range Content of iron oxides calculated as Fe: Iron(III) oxide Iron(II) oxide Triiron tetraoxide respirable fraction inhalable fraction Range Content of nickel compounds calculated as Ni inhalable fraction respirable fraction Range Metallic nickel content Range Content of metallic chromium, chromium compounds: (chromium (II), chromium (III), chromium (VI) – expressed as Cr Range ISO 15202-3:2004-11","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(10 - 1250) μg w próbce"},{"name":"铜及其无机化合物含量（以 Cu 计）"},{"name":"范围","range":"(5 - 250) μg w próbce"},{"name":"锰及其无机化合物含量（以 Mn 计）"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(3 - 1250) μg w próbce"},{"name":"Zawartość tlenków żelaza w przeliczeniu na Fe: Tlenek żelaza(III) Tlenek żelaza(II) Tetratlenek triżelaza"},{"name":"呼吸性组分"},{"name":"可吸入组分"},{"name":"范围","range":"(10 - 1250) μg w próbce"},{"name":"镍化合物含量（以 Ni 计）"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,50 - 120) μg w próbce"},{"name":"金属镍含量"},{"name":"范围","range":"(0,50 - 400) μg w próbce"},{"name":"Zawartość chromu metalicznego, związków chromu: (chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr"},{"name":"范围","range":"(1 - 125) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氧化锌含量（以 Zn 计） 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 范围 铜及其无机化合物含量（以 Cu 计） 范围 锰及其无机化合物含量（以 Mn 计） 可吸入组分 呼吸性组分 范围 呼吸性组分 可吸入组分 范围 镍化合物含量（以 Ni 计） 可吸入组分 呼吸性组分 范围 金属镍含量 范围 范围 ISO 15202-3:2004-11","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"氧化锌含量（以 Zn 计）"},{"_id":"6a83bcf4af14b9c0e7b21395","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość glinu metalicznego, glin proszek (niestabilizowany)","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna Zawartość tritlenku glinu w przeliczeniu na Al"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna Zawartość wodorotlenku glinu w przeliczeniu na Al"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(8,5 - 1250) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość glinu metalicznego, glin proszek (niestabilizowany)\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna Zawartość tritlenku glinu w przeliczeniu na Al\nfrakcja wdychalna\nfrakcja respirabilna Zawartość wodorotlenku glinu w przeliczeniu na Al\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (8,5 - 1250) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"ISO 15202-3:2004-11","norm_bases":["ISO 15202-3:2004-11"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość glinu metalicznego, glin proszek (niestabilizowany)\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna Zawartość tritlenku glinu w przeliczeniu na Al\nfrakcja wdychalna\nfrakcja respirabilna Zawartość wodorotlenku glinu w przeliczeniu na Al\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (8,5 - 1250) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) ISO 15202-3:2004-11 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc glinu metalicznego, glin proszek (niestabilizowany)\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna Zawartosc tritlenku glinu w przeliczeniu na Al\nfrakcja wdychalna\nfrakcja respirabilna Zawartosc wodorotlenku glinu w przeliczeniu na Al\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (8,5 - 1250) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) ISO 15202-3:2004-11","categories":["materials","environment"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metallic aluminium content, aluminium powder (unstabilised)","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction Aluminium trioxide content expressed as Al"},{"name":"inhalable fraction"},{"name":"respirable fraction Aluminium hydroxide content expressed as Al"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(8,5 - 1250) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Metallic aluminium content, aluminium powder (unstabilised) Inductively coupled plasma optical emission spectrometry (ICP-OES) inhalable fraction respirable fraction Aluminium trioxide content expressed as Al inhalable fraction respirable fraction Aluminium hydroxide content expressed as Al inhalable fraction respirable fraction Range ISO 15202-3:2004-11","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"frakcja respirabilna Zawartość tritlenku glinu w przeliczeniu na Al"},{"name":"可吸入组分"},{"name":"frakcja respirabilna Zawartość wodorotlenku glinu w przeliczeniu na Al"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(8,5 - 1250) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电感耦合等离子体原子发射光谱法（ICP-OES） 可吸入组分 可吸入组分 可吸入组分 呼吸性组分 范围 ISO 15202-3:2004-11","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b21396","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Związki chromu(VI) – w przeliczeniu na Cr(VI)","parameters":[{"name":"Zakres","range":"(0,8 - 10,0) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Związki chromu(VI) – w przeliczeniu na Cr(VI)\nZakres (0,8 - 10,0) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126/03","norm_bases":["PN-87/Z-04126/03"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Związki chromu(VI) – w przeliczeniu na Cr(VI)\nZakres (0,8 - 10,0) μg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126/03 Srodowisko pracy - probki powietrza pobrane na filtry Zwiazki chromu(VI) – w przeliczeniu na Cr(VI)\nZakres (0,8 - 10,0) μg w probce\nMetoda spektrofotometryczna PN-87/Z-04126/03","categories":["environment"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) compounds – calculated as Cr(VI)","parameters_en":[{"name":"Range","range":"(0,8 - 10,0) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Chromium(VI) compounds – calculated as Cr(VI) Spectrophotometric method Range PN-87/Z-04126/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,8 - 10,0) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 分光光度法 范围 PN-87/Z-04126/03","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21397","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Związki chromu(VI) – w przeliczeniu na Cr(VI)","parameters":[{"name":"Zakres","range":"(0,2 - 7,0) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Związki chromu(VI) – w przeliczeniu na Cr(VI)\nZakres (0,2 - 7,0) μg w próbce\nMetoda spektrofotometryczna","reference":"Metodyka NIOSH Manual of Analytical Methods, Method 7600 Issue 3, październik 2015","norm_bases":["Metodyka NIOSH Manual of Analytical Methods, Method 7600 Issue 3, październik 2015"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Związki chromu(VI) – w przeliczeniu na Cr(VI)\nZakres (0,2 - 7,0) μg w próbce\nMetoda spektrofotometryczna Metodyka NIOSH Manual of Analytical Methods, Method 7600 Issue 3, październik 2015 Srodowisko pracy - probki powietrza pobrane na filtry Zwiazki chromu(VI) – w przeliczeniu na Cr(VI)\nZakres (0,2 - 7,0) μg w probce\nMetoda spektrofotometryczna Metodyka NIOSH Manual of Analytical Methods, Method 7600 Issue 3, pazdziernik 2015","categories":["environment"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) compounds – calculated as Cr(VI)","parameters_en":[{"name":"Range","range":"(0,2 - 7,0) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Chromium(VI) compounds – calculated as Cr(VI) Spectrophotometric method Range Metodyka NIOSH Manual of Analytical Methods, Method 7600 Issue 3, październik 2015","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,2 - 7,0) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 分光光度法 范围 Metodyka NIOSH Manual of Analytical Methods, Method 7600 Issue 3, październik 2015","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b21398","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,005 - 1) mg w próbce"}],"technique":"Metoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość wodorotlenku sodu\nZakres (0,005 - 1) mg w próbce\nMetoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-Z-04435:2011 IR-17 wydanie nr 1 z dnia 03.06.2019 r.","norm_bases":["PN-Z-04435:2011 IR-17 wydanie nr 1 z dnia 03.06.2019 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość wodorotlenku sodu\nZakres (0,005 - 1) mg w próbce\nMetoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-Z-04435:2011 IR-17 wydanie nr 1 z dnia 03.06.2019 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc wodorotlenku sodu\nZakres (0,005 - 1) mg w probce\nMetoda atomowej spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-Z-04435:2011 IR-17 wydanie nr 1 z dnia 03.06.2019 r.","categories":["environment"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium hydroxide content","parameters_en":[{"name":"Range","range":"(0,005 - 1) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Sodium hydroxide content Inductively coupled plasma mass spectrometry (ICP-MS) Range PN-Z-04435:2011 IR-17 wydanie nr 1 z dnia 03.06.2019 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,005 - 1) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氢氧化钠含量 范围 PN-Z-04435:2011 IR-17 wydanie nr 1 z dnia 03.06.2019 r.","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"氢氧化钠含量"},{"_id":"6a83bcf4af14b9c0e7b21399","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,005 - 1) mg w próbce"}],"technique":"Metoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość wodorotlenku potasu\nZakres (0,005 - 1) mg w próbce\nMetoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-Z-04436:2011 IR-18 wydanie nr 1 z dnia 03.06.2019 r.","norm_bases":["PN-Z-04436:2011 IR-18 wydanie nr 1 z dnia 03.06.2019 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość wodorotlenku potasu\nZakres (0,005 - 1) mg w próbce\nMetoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-Z-04436:2011 IR-18 wydanie nr 1 z dnia 03.06.2019 r. Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc wodorotlenku potasu\nZakres (0,005 - 1) mg w probce\nMetoda atomowej spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-Z-04436:2011 IR-18 wydanie nr 1 z dnia 03.06.2019 r.","categories":["environment"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium hydroxide content","parameters_en":[{"name":"Range","range":"(0,005 - 1) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Potassium hydroxide content Inductively coupled plasma mass spectrometry (ICP-MS) Range PN-Z-04436:2011 IR-18 wydanie nr 1 z dnia 03.06.2019 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,005 - 1) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氢氧化钾含量 范围 PN-Z-04436:2011 IR-18 wydanie nr 1 z dnia 03.06.2019 r.","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"氢氧化钾含量"},{"_id":"6a83bcf4af14b9c0e7b2139a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość wapnia","parameters":[{"name":"Ca (10 - 1250) μg w próbce CaCO3 - frakcja wdychalna"},{"name":"Zakres","range":"(25 - 3125) μg w próbce"},{"name":"CaO - frakcja wdychalna"},{"name":"frakcja respirabilna (14 - 1750) μg w próbce Ca(OH)2 - frakcja wdychalna"},{"name":"frakcja respirabilna (18,8 - 2300) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość wapnia\nZakres:\nCa (10 - 1250) μg w próbce CaCO3 - frakcja wdychalna\nZakres (25 - 3125) μg w próbce\nCaO - frakcja wdychalna\nfrakcja respirabilna (14 - 1750) μg w próbce Ca(OH)2 - frakcja wdychalna\nfrakcja respirabilna (18,8 - 2300) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość wapnia\nZakres:\nCa (10 - 1250) μg w próbce CaCO3 - frakcja wdychalna\nZakres (25 - 3125) μg w próbce\nCaO - frakcja wdychalna\nfrakcja respirabilna (14 - 1750) μg w próbce Ca(OH)2 - frakcja wdychalna\nfrakcja respirabilna (18,8 - 2300) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc wapnia\nZakres:\nCa (10 - 1250) μg w probce CaCO3 - frakcja wdychalna\nZakres (25 - 3125) μg w probce\nCaO - frakcja wdychalna\nfrakcja respirabilna (14 - 1750) μg w probce Ca(OH)2 - frakcja wdychalna\nfrakcja respirabilna (18,8 - 2300) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesien 2002","categories":["environment"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium content","parameters_en":[{"name":"Ca (10 - 1250) μg in the sample CaCO3 - inhalable fraction"},{"name":"Range","range":"(25 - 3125) μg w próbce"},{"name":"CaO - inhalable fraction"},{"name":"respirable fraction (14 - 1750) μg in sample Ca(OH)2 - inhalable fraction"},{"name":"respirable fraction (18,8 - 2300) μg in sample"}],"search_en":"Workplace environment - air samples collected on filters Calcium content Inductively coupled plasma optical emission spectrometry (ICP-OES) Ca (10 - 1250) μg in the sample CaCO3 - inhalable fraction Range CaO - inhalable fraction respirable fraction (14 - 1750) μg in sample Ca(OH)2 - inhalable fraction respirable fraction (18,8 - 2300) μg in sample Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"Ca (10 - 1250) μg w próbce CaCO3 - frakcja wdychalna"},{"name":"范围","range":"(25 - 3125) μg w próbce"},{"name":"CaO - frakcja wdychalna"},{"name":"frakcja respirabilna (14 - 1750) μg w próbce Ca(OH)2 - frakcja wdychalna"},{"name":"frakcja respirabilna (18,8 - 2300) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 钙含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-125G, wrzesień 2002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"钙含量","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b2139b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,5 - 125) μg w próbce"},{"name":"Zawartość berylu i jego związków nieorganicznych w przeliczeniu na Be"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,006 - 5) μg w próbce"},{"name":"Zawartość selenu i jego związków z wyjątkiem selanu w przeliczeniu na Se"},{"name":"Zakres","range":"(0,25 - 6) μg w próbce"},{"name":"Zawartość srebra"},{"name":"frakcja wdychalna"},{"name":"związki nierozpuszczalne w przeliczeniu na Ag"},{"name":"związki rozpuszczalne w przeliczeniu na Ag"},{"name":"Zakres","range":"(0,25 - 25) μg w próbce"},{"name":"Zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb – frakcja wdychalna"},{"name":"Zakres","range":"(1 - 100) μg w próbce"},{"name":"Zawartość cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn"},{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(2,5 - 250) μg w próbce"}],"technique":"Metoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,5 - 125) μg w próbce\nZawartość berylu i jego związków nieorganicznych w przeliczeniu na Be\nfrakcja wdychalna\nZakres (0,006 - 5) μg w próbce\nZawartość selenu i jego związków z wyjątkiem selanu w przeliczeniu na Se\nZakres (0,25 - 6) μg w próbce\nZawartość srebra\nfrakcja wdychalna\nzwiązki nierozpuszczalne w przeliczeniu na Ag\nzwiązki rozpuszczalne w przeliczeniu na Ag\nZakres (0,25 - 25) μg w próbce\nZawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb – frakcja wdychalna\nZakres (1 - 100) μg w próbce\nZawartość cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn\nfrakcja wdychalna\nZakres (2,5 - 250) μg w próbce\nMetoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"ISO 30011:2010","norm_bases":["ISO 30011:2010"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,5 - 125) μg w próbce\nZawartość berylu i jego związków nieorganicznych w przeliczeniu na Be\nfrakcja wdychalna\nZakres (0,006 - 5) μg w próbce\nZawartość selenu i jego związków z wyjątkiem selanu w przeliczeniu na Se\nZakres (0,25 - 6) μg w próbce\nZawartość srebra\nfrakcja wdychalna\nzwiązki nierozpuszczalne w przeliczeniu na Ag\nzwiązki rozpuszczalne w przeliczeniu na Ag\nZakres (0,25 - 25) μg w próbce\nZawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb – frakcja wdychalna\nZakres (1 - 100) μg w próbce\nZawartość cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn\nfrakcja wdychalna\nZakres (2,5 - 250) μg w próbce\nMetoda atomowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) ISO 30011:2010 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc arsenu i jego zwiazkow nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,5 - 125) μg w probce\nZawartosc berylu i jego zwiazkow nieorganicznych w przeliczeniu na Be\nfrakcja wdychalna\nZakres (0,006 - 5) μg w probce\nZawartosc selenu i jego zwiazkow z wyjatkiem selanu w przeliczeniu na Se\nZakres (0,25 - 6) μg w probce\nZawartosc srebra\nfrakcja wdychalna\nzwiazki nierozpuszczalne w przeliczeniu na Ag\nzwiazki rozpuszczalne w przeliczeniu na Ag\nZakres (0,25 - 25) μg w probce\nZawartosc olowiu i jego zwiazkow nieorganicznych – w przeliczeniu na Pb – frakcja wdychalna\nZakres (1 - 100) μg w probce\nZawartosc cyny i jej zwiazkow nieorganicznych z wyjatkiem stannanu w przeliczeniu na Sn\nfrakcja wdychalna\nZakres (2,5 - 250) μg w probce\nMetoda atomowej spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) ISO 30011:2010","categories":["environment"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of arsenic and its inorganic compounds calculated as As","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,5 - 125) μg w próbce"},{"name":"Content of beryllium and its inorganic compounds calculated as Be"},{"name":"inhalable fraction"},{"name":"Range","range":"(0,006 - 5) μg w próbce"},{"name":"Content of selenium and its compounds excluding selane calculated as Se"},{"name":"Range","range":"(0,25 - 6) μg w próbce"},{"name":"Silver content"},{"name":"inhalable fraction"},{"name":"insoluble compounds expressed as Ag"},{"name":"soluble compounds calculated as Ag"},{"name":"Range","range":"(0,25 - 25) μg w próbce"},{"name":"Content of lead and its inorganic compounds – calculated as Pb – inhalable fraction"},{"name":"Range","range":"(1 - 100) μg w próbce"},{"name":"Content of tin and its inorganic compounds excluding stannane calculated as Sn"},{"name":"inhalable fraction"},{"name":"Range","range":"(2,5 - 250) μg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of arsenic and its inorganic compounds calculated as As Inductively coupled plasma mass spectrometry (ICP-MS) inhalable fraction Range Content of beryllium and its inorganic compounds calculated as Be inhalable fraction Range Content of selenium and its compounds excluding selane calculated as Se Range Silver content inhalable fraction insoluble compounds expressed as Ag soluble compounds calculated as Ag Range Content of lead and its inorganic compounds – calculated as Pb – inhalable fraction Range Content of tin and its inorganic compounds excluding stannane calculated as Sn inhalable fraction Range ISO 30011:2010","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,5 - 125) μg w próbce"},{"name":"Zawartość berylu i jego związków nieorganicznych w przeliczeniu na Be"},{"name":"可吸入组分"},{"name":"范围","range":"(0,006 - 5) μg w próbce"},{"name":"Zawartość selenu i jego związków z wyjątkiem selanu w przeliczeniu na Se"},{"name":"范围","range":"(0,25 - 6) μg w próbce"},{"name":"银含量"},{"name":"可吸入组分"},{"name":"związki nierozpuszczalne w przeliczeniu na Ag"},{"name":"związki rozpuszczalne w przeliczeniu na Ag"},{"name":"范围","range":"(0,25 - 25) μg w próbce"},{"name":"Zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb – frakcja wdychalna"},{"name":"范围","range":"(1 - 100) μg w próbce"},{"name":"Zawartość cyny i jej związków nieorganicznych z wyjątkiem stannanu w przeliczeniu na Sn"},{"name":"可吸入组分"},{"name":"范围","range":"(2,5 - 250) μg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 可吸入组分 范围 可吸入组分 范围 范围 银含量 可吸入组分 范围 范围 可吸入组分 范围 ISO 30011:2010","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品"},{"_id":"6a83bcf4af14b9c0e7b2139c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,0010 - 0,0360) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną"],"computed":[],"activity":"Zawartość ozonu\nZakres (0,0010 - 0,0360) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną","reference":"Metodyka OSHA Technical Center Salt Lake City nr ID-214, styczeń 2008","norm_bases":["Metodyka OSHA Technical Center Salt Lake City nr ID-214, styczeń 2008"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość ozonu\nZakres (0,0010 - 0,0360) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną Metodyka OSHA Technical Center Salt Lake City nr ID-214, styczeń 2008 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc ozonu\nZakres (0,0010 - 0,0360) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna Metodyka OSHA Technical Center Salt Lake City nr ID-214, styczen 2008","categories":["environment"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone content","parameters_en":[{"name":"Range","range":"(0,0010 - 0,0360) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Ozone content Ion chromatography with conductometric detection Range Metodyka OSHA Technical Center Salt Lake City nr ID-214, styczeń 2008","technique_en":"Ion chromatography with conductometric detection","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0010 - 0,0360) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 臭氧含量 离子色谱-电导检测法 范围 Metodyka OSHA Technical Center Salt Lake City nr ID-214, styczeń 2008","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"离子色谱-电导检测法","methodology_zh":"臭氧含量"},{"_id":"6a83bcf4af14b9c0e7b2139d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość kwasu fosforowego","parameters":[{"name":"Zakres","range":"(0,004 - 1,44) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną"],"computed":[],"activity":"Zawartość kwasu fosforowego\nZakres (0,004 - 1,44) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną","reference":"Metodyka NIOSH Manual of Analytical Methods, Method 7908 Issue 1, 10 Maj 2014","norm_bases":["Metodyka NIOSH Manual of Analytical Methods, Method 7908 Issue 1, 10 Maj 2014"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość kwasu fosforowego\nZakres (0,004 - 1,44) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną Metodyka NIOSH Manual of Analytical Methods, Method 7908 Issue 1, 10 Maj 2014 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc kwasu fosforowego\nZakres (0,004 - 1,44) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna Metodyka NIOSH Manual of Analytical Methods, Method 7908 Issue 1, 10 Maj 2014","categories":["environment"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphoric acid content","parameters_en":[{"name":"Range","range":"(0,004 - 1,44) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Phosphoric acid content Ion chromatography with conductometric detection Range Metodyka NIOSH Manual of Analytical Methods, Method 7908 Issue 1, 10 Maj 2014","technique_en":"Ion chromatography with conductometric detection","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,004 - 1,44) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 离子色谱-电导检测法 范围 Metodyka NIOSH Manual of Analytical Methods, Method 7908 Issue 1, 10 Maj 2014","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","technique_zh":"离子色谱-电导检测法"},{"_id":"6a83bcf4af14b9c0e7b2139e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość:","parameters":[{"name":"metylenobis(fenyloizocyjanianu)"},{"name":"Zakres","range":"(0,00050 - 0,015) mg w"},{"name":"próbce"},{"name":"diizocyjanianu tolueno-2,4-diylu"},{"name":"Zakres","range":"(0,000075 - 0,0075) mg w"},{"name":"próbce"},{"name":"diizocyjanianu tolueno-2,6-diylu"},{"name":"Zakres","range":"(0,000075 - 0,0075) mg w"},{"name":"próbce"},{"name":"diizocyjanianu toluenodiylu (mieszanina izomerów 2,4- i 2,6-) (z obliczeń)"},{"name":"diizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)"},{"name":"Zakres","range":"(0,00050 - 0,025) mg w"},{"name":"próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD"],"computed":[],"activity":"Zawartość:\nZakres:\nmetylenobis(fenyloizocyjanianu)\nZakres (0,00050 - 0,015) mg w\npróbce\ndiizocyjanianu tolueno-2,4-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu tolueno-2,6-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu toluenodiylu (mieszanina izomerów 2,4- i 2,6-) (z obliczeń)\ndiizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)\nZakres (0,00050 - 0,025) mg w\npróbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD","reference":"OSHA Method 5002","norm_bases":["OSHA Method 5002"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość:\nZakres:\nmetylenobis(fenyloizocyjanianu)\nZakres (0,00050 - 0,015) mg w\npróbce\ndiizocyjanianu tolueno-2,4-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu tolueno-2,6-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu toluenodiylu (mieszanina izomerów 2,4- i 2,6-) (z obliczeń)\ndiizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)\nZakres (0,00050 - 0,025) mg w\npróbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD OSHA Method 5002 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc:\nZakres:\nmetylenobis(fenyloizocyjanianu)\nZakres (0,00050 - 0,015) mg w\nprobce\ndiizocyjanianu tolueno-2,4-diylu\nZakres (0,000075 - 0,0075) mg w\nprobce\ndiizocyjanianu tolueno-2,6-diylu\nZakres (0,000075 - 0,0075) mg w\nprobce\ndiizocyjanianu toluenodiylu (mieszanina izomerow 2,4- i 2,6-) (z obliczen)\ndiizocyjanianu heksano-1,6-diylu (szesciometylenodwuizocyjanianu)\nZakres (0,00050 - 0,025) mg w\nprobce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD OSHA Method 5002","categories":["environment"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content:","parameters_en":[{"name":"methylenebis(phenyl isocyanate)"},{"name":"Range","range":"(0,00050 - 0,015) mg w"},{"name":"sample"},{"name":"toluene-2,4-diyl diisocyanate"},{"name":"Range","range":"(0,000075 - 0,0075) mg w"},{"name":"sample"},{"name":"toluene-2,6-diyl diisocyanate"},{"name":"Range","range":"(0,000075 - 0,0075) mg w"},{"name":"sample"},{"name":"toluenediyl diisocyanate (mixture of 2,4- and 2,6- isomers) (calculated)"},{"name":"hexane-1,6-diyl diisocyanate (hexamethylene diisocyanate)"},{"name":"Range","range":"(0,00050 - 0,025) mg w"},{"name":"sample"}],"search_en":"Workplace environment - air samples collected on filters Content: High-performance liquid chromatography with fluorescence detection (HPLC-FLD methylenebis(phenyl isocyanate) Range sample toluene-2,4-diyl diisocyanate Range sample toluene-2,6-diyl diisocyanate Range sample toluenediyl diisocyanate (mixture of 2,4- and 2,6- isomers) (calculated) hexane-1,6-diyl diisocyanate (hexamethylene diisocyanate) Range sample OSHA Method 5002","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"metylenobis(fenyloizocyjanianu)"},{"name":"范围","range":"(0,00050 - 0,015) mg w"},{"name":"样品中"},{"name":"甲苯-2,4-二异氰酸酯"},{"name":"范围","range":"(0,000075 - 0,0075) mg w"},{"name":"样品中"},{"name":"甲苯-2,6-二异氰酸酯"},{"name":"范围","range":"(0,000075 - 0,0075) mg w"},{"name":"样品中"},{"name":"diizocyjanianu toluenodiylu (mieszanina izomerów 2,4- i 2,6-) (z obliczeń)"},{"name":"diizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)"},{"name":"范围","range":"(0,00050 - 0,025) mg w"},{"name":"样品中"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 含量： 范围 样品中 甲苯-2,4-二异氰酸酯 范围 样品中 甲苯-2,6-二异氰酸酯 范围 样品中 范围 样品中 OSHA Method 5002","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","methodology_zh":"含量："},{"_id":"6a83bcf4af14b9c0e7b2139f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne","methodology":"Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,02 - 15,0) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną"],"computed":[],"activity":"Zawartość chlorowodoru\nZakres (0,02 - 15,0) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne Zawartość chlorowodoru\nZakres (0,02 - 15,0) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną PN-EN 1911:2011 Srodowisko ogolne Zawartosc chlorowodoru\nZakres (0,02 - 15,0) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna PN-EN 1911:2011","categories":["environment"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride content","parameters_en":[{"name":"Range","range":"(0,02 - 15,0) mg w próbce"}],"search_en":"General environment Hydrogen chloride content Ion chromatography with conductometric detection Range PN-EN 1911:2011","technique_en":"Ion chromatography with conductometric detection","test_object_en":"General environment","parameters_zh":[{"name":"范围","range":"(0,02 - 15,0) mg w próbce"}],"search_zh":"一般环境 氯化氢含量 离子色谱-电导检测法 范围 PN-EN 1911:2011","methodology_zh":"氯化氢含量","test_object_zh":"一般环境","technique_zh":"离子色谱-电导检测法"},{"_id":"6a83bcf4af14b9c0e7b213a0","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne","methodology":"Zawartość fluorowodoru","parameters":[{"name":"Zakres","range":"(0,05 - 1) mg w próbce"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Zawartość fluorowodoru\nZakres (0,05 - 1) mg w próbce\nMetoda elektrochemiczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne Zawartość fluorowodoru\nZakres (0,05 - 1) mg w próbce\nMetoda elektrochemiczna ISO 15713:2006 Srodowisko ogolne Zawartosc fluorowodoru\nZakres (0,05 - 1) mg w probce\nMetoda elektrochemiczna ISO 15713:2006","categories":["environment"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride content","parameters_en":[{"name":"Range","range":"(0,05 - 1) mg w próbce"}],"search_en":"General environment Hydrogen fluoride content Electrochemical method Range ISO 15713:2006","technique_en":"Electrochemical method","test_object_en":"General environment","parameters_zh":[{"name":"范围","range":"(0,05 - 1) mg w próbce"}],"search_zh":"一般环境 氟化氢含量 电化学法 范围 ISO 15713:2006","technique_zh":"电化学法","methodology_zh":"氟化氢含量","test_object_zh":"一般环境"},{"_id":"6a83bcf4af14b9c0e7b213a1","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane na filtry - próbki gazów odlotowych pobrane do roztworów pochłaniających","methodology":"Zawartość pierwiastków:","parameters":[{"name":"Zakres : As (5,0 - 125) μg w próbce"},{"name":"B (5 - 125) μg w próbce"},{"name":"Ba (1 - 12,5) μg w próbce"},{"name":"Cd (1 - 125) μg w próbce"},{"name":"Co (5,0 - 120) μg w próbce"},{"name":"Cr (5,0 - 120) μg w próbce"},{"name":"Cu (10 - 125) μg w próbce"},{"name":"Fe (20 - 7500) μg w próbce"},{"name":"Mn (5 - 2500) μg w próbce"},{"name":"Mo (5 - 120) μg w próbce"},{"name":"Ni (5,0 - 120) μg w próbce"},{"name":"Pb (15 - 120) μg w próbce"},{"name":"Sb (10 - 250) μg w próbce"},{"name":"Se (30 - 120) μg w próbce"},{"name":"Sn (20 - 250) μg w próbce"},{"name":"Ti (5,0 – 120) μg w próbce"},{"name":"Tl (50 - 250) μg w próbce"},{"name":"Zn (20 - 1250) μg w próbce"},{"name":"V (5,0 - 250) μg w próbce"}],"technique":"Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków:\nZakres:\nZakres : As (5,0 - 125) μg w próbce\nB (5 - 125) μg w próbce\nBa (1 - 12,5) μg w próbce\nCd (1 - 125) μg w próbce\nCo (5,0 - 120) μg w próbce\nCr (5,0 - 120) μg w próbce\nCu (10 - 125) μg w próbce\nFe (20 - 7500) μg w próbce\nMn (5 - 2500) μg w próbce\nMo (5 - 120) μg w próbce\nNi (5,0 - 120) μg w próbce\nPb (15 - 120) μg w próbce\nSb (10 - 250) μg w próbce\nSe (30 - 120) μg w próbce\nSn (20 - 250) μg w próbce\nTi (5,0 – 120) μg w próbce\nTl (50 - 250) μg w próbce\nZn (20 - 1250) μg w próbce\nV (5,0 - 250) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane na filtry - próbki gazów odlotowych pobrane do roztworów pochłaniających Zawartość pierwiastków:\nZakres:\nZakres : As (5,0 - 125) μg w próbce\nB (5 - 125) μg w próbce\nBa (1 - 12,5) μg w próbce\nCd (1 - 125) μg w próbce\nCo (5,0 - 120) μg w próbce\nCr (5,0 - 120) μg w próbce\nCu (10 - 125) μg w próbce\nFe (20 - 7500) μg w próbce\nMn (5 - 2500) μg w próbce\nMo (5 - 120) μg w próbce\nNi (5,0 - 120) μg w próbce\nPb (15 - 120) μg w próbce\nSb (10 - 250) μg w próbce\nSe (30 - 120) μg w próbce\nSn (20 - 250) μg w próbce\nTi (5,0 – 120) μg w próbce\nTl (50 - 250) μg w próbce\nZn (20 - 1250) μg w próbce\nV (5,0 - 250) μg w próbce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 14385:2025-05 Srodowisko ogolne - probki gazow odlotowych pobrane na filtry - probki gazow odlotowych pobrane do roztworow pochlaniajacych Zawartosc pierwiastkow:\nZakres:\nZakres : As (5,0 - 125) μg w probce\nB (5 - 125) μg w probce\nBa (1 - 12,5) μg w probce\nCd (1 - 125) μg w probce\nCo (5,0 - 120) μg w probce\nCr (5,0 - 120) μg w probce\nCu (10 - 125) μg w probce\nFe (20 - 7500) μg w probce\nMn (5 - 2500) μg w probce\nMo (5 - 120) μg w probce\nNi (5,0 - 120) μg w probce\nPb (15 - 120) μg w probce\nSb (10 - 250) μg w probce\nSe (30 - 120) μg w probce\nSn (20 - 250) μg w probce\nTi (5,0 – 120) μg w probce\nTl (50 - 250) μg w probce\nZn (20 - 1250) μg w probce\nV (5,0 - 250) μg w probce\nMetoda emisyjnej spektrometrii atomowej z wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 14385:2025-05","categories":["environment"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content:","parameters_en":[{"name":"Range : As (5,0 - 125) μg per sample"},{"name":"B (5 - 125) μg in the sample"},{"name":"Ba (1 - 12,5) μg in the sample"},{"name":"Cd (1 - 125) μg in the sample"},{"name":"Co (5,0 - 120) μg in the sample"},{"name":"Cr (5,0 - 120) μg in the sample"},{"name":"Cu (10 - 125) μg in the sample"},{"name":"Fe (20 - 7500) μg in sample"},{"name":"Mn (5 - 2500) μg in sample"},{"name":"Mo (5 - 120) μg in sample"},{"name":"Ni (5,0 - 120) μg in sample"},{"name":"Pb (15 - 120) μg in sample"},{"name":"Sb (10 - 250) μg per sample"},{"name":"Se (30 - 120) μg per sample"},{"name":"Sn (20 - 250) μg per sample"},{"name":"Ti (5,0 – 120) μg per sample"},{"name":"Tl (50 - 250) μg per sample"},{"name":"Zn (20 - 1250) μg per sample"},{"name":"V (5,0 - 250) μg per sample"}],"search_en":"General environment - waste gas samples collected on filters - waste gas samples collected into absorbing solutions Element content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Range : As (5,0 - 125) μg per sample B (5 - 125) μg in the sample Ba (1 - 12,5) μg in the sample Cd (1 - 125) μg in the sample Co (5,0 - 120) μg in the sample Cr (5,0 - 120) μg in the sample Cu (10 - 125) μg in the sample Fe (20 - 7500) μg in sample Mn (5 - 2500) μg in sample Mo (5 - 120) μg in sample Ni (5,0 - 120) μg in sample Pb (15 - 120) μg in sample Sb (10 - 250) μg per sample Se (30 - 120) μg per sample Sn (20 - 250) μg per sample Ti (5,0 – 120) μg per sample Tl (50 - 250) μg per sample Zn (20 - 1250) μg per sample V (5,0 - 250) μg per sample PN-EN 14385:2025-05","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"General environment - waste gas samples collected on filters - waste gas samples collected into absorbing solutions","methodology_zh":"元素含量：","search_zh":"元素含量： 电感耦合等离子体原子发射光谱法（ICP-OES） PN-EN 14385:2025-05","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83bcf4af14b9c0e7b213a2","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,008 - 2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość amoniaku\nZakres (0,008 - 2) mg w próbce\nMetoda spektrofotometryczna","reference":"EKOLAB/LB/PB-75 wydanie 3 z dnia 06.05.2011 r.","norm_bases":["EKOLAB/LB/PB-75 wydanie 3 z dnia 06.05.2011 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość amoniaku\nZakres (0,008 - 2) mg w próbce\nMetoda spektrofotometryczna EKOLAB/LB/PB-75 wydanie 3 z dnia 06.05.2011 r. Srodowisko pracy Zawartosc amoniaku\nZakres (0,008 - 2) mg w probce\nMetoda spektrofotometryczna EKOLAB/LB/PB-75 wydanie 3 z dnia 06.05.2011 r.","categories":["environment"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia content","parameters_en":[{"name":"Range","range":"(0,008 - 2) mg w próbce"}],"search_en":"Workplace environment Ammonia content Spectrophotometric method Range EKOLAB/LB/PB-75 wydanie 3 z dnia 06.05.2011 r.","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,008 - 2) mg w próbce"}],"search_zh":"工作场所环境 氨含量 分光光度法 范围 EKOLAB/LB/PB-75 wydanie 3 z dnia 06.05.2011 r.","technique_zh":"分光光度法","test_object_zh":"工作场所环境","methodology_zh":"氨含量"},{"_id":"6a83bcf4af14b9c0e7b213a3","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne","methodology":"Zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,003 - 0,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość fenolu\nZakres (0,003 - 0,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/2-04159/02","norm_bases":["PN-86/2-04159/02"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne Zawartość fenolu\nZakres (0,003 - 0,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/2-04159/02 Srodowisko ogolne Zawartosc fenolu\nZakres (0,003 - 0,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/2-04159/02","categories":["environment"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol content","parameters_en":[{"name":"Range","range":"(0,003 - 0,2) mg w próbce"}],"search_en":"General environment Phenol content Gas chromatography with flame ionization detection (GC-FID) Range PN-86/2-04159/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment","parameters_zh":[{"name":"范围","range":"(0,003 - 0,2) mg w próbce"}],"search_zh":"一般环境 苯酚含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-86/2-04159/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"苯酚含量","test_object_zh":"一般环境"},{"_id":"6a83bcf4af14b9c0e7b213a4","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,0005 - 0,5) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość formaldehydu\nZakres (0,0005 - 0,5) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"Metodyka NIOSH Manual of Analytical Methods, Method 2016, Issue 2, Marzec 2003","norm_bases":["Metodyka NIOSH Manual of Analytical Methods, Method 2016, Issue 2, Marzec 2003"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość formaldehydu\nZakres (0,0005 - 0,5) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) Metodyka NIOSH Manual of Analytical Methods, Method 2016, Issue 2, Marzec 2003 Srodowisko pracy Zawartosc formaldehydu\nZakres (0,0005 - 0,5) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) Metodyka NIOSH Manual of Analytical Methods, Method 2016, Issue 2, Marzec 2003","categories":["environment"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(0,0005 - 0,5) mg w próbce"}],"search_en":"Workplace environment Formaldehyde content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) Range Metodyka NIOSH Manual of Analytical Methods, Method 2016, Issue 2, Marzec 2003","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,5) mg w próbce"}],"search_zh":"工作场所环境 甲醛含量 高效液相色谱-分光光度检测法（HPLC-UV-VIS） 范围 Metodyka NIOSH Manual of Analytical Methods, Method 2016, Issue 2, Marzec 2003","test_object_zh":"工作场所环境","methodology_zh":"甲醛含量","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV-VIS）"},{"_id":"6a83bcf4af14b9c0e7b213a5","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem","methodology":"Zawartość akrylaldehydu","parameters":[{"name":"Zakres","range":"(0,15 - 3,5) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość akrylaldehydu\nZakres (0,15 - 3,5) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"PN-Z-04045-16:2010","norm_bases":["PN-Z-04045-16:2010"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z sorbentem Zawartość akrylaldehydu\nZakres (0,15 - 3,5) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) PN-Z-04045-16:2010 Srodowisko pracy - probki powietrza pobrane na rurki z sorbentem Zawartosc akrylaldehydu\nZakres (0,15 - 3,5) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) PN-Z-04045-16:2010","categories":["environment"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylaldehyde content","parameters_en":[{"name":"Range","range":"(0,15 - 3,5) μg w próbce"}],"search_en":"Workplace environment - air samples collected on sorbent tubes Acrylaldehyde content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) Range PN-Z-04045-16:2010","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS)","test_object_en":"Workplace environment - air samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,15 - 3,5) μg w próbce"}],"search_zh":"工作场所环境 — 用吸附管采集的空气样品 高效液相色谱-分光光度检测法（HPLC-UV-VIS） 范围 PN-Z-04045-16:2010","test_object_zh":"工作场所环境 — 用吸附管采集的空气样品","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV-VIS）"},{"_id":"6a83bcf4af14b9c0e7b213a6","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość węglowodorów i ich pochodnych aceton (0,01 - 15) mg w próbce pentan (0,01 - 15) mg w próbce octan metylu (0,01 - 15) mg w próbce butan-2-on (0,01 - 15) mg w próbce octan etylu (0,01 - 15) mg w próbce heksan (0,01 - 5) mg w próbce 2-metylopropan-1-ol (0,01 - 5) mg w próbce octan izopropylu (0,01 - 15) mg w próbce benzen (0,001 - 3) mg w próbce butan 1-ol (0,01 - 5) mg w próbce cykloheksan (0,01 - 15) mg w próbce metakrylan metylu (0,01 - 5) mg w próbce pentan-1-ol (0,01 - 5) mg w próbce toluen (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce tetrachloroeten (0,01 - 5) mg w próbce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w próbce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w próbce etylobenzen (0,01 - 5) mg w próbce ksylen-mieszanina izomerów: 1,2-;1,3; 1,4- (0,01 - 5) mg w próbce cykloheksanon (0,01 - 3) mg w próbce 2-butoksyetanol (0,01 - 5) mg w próbce styren (0,01 - 3) mg w próbce kumen (0,01 - 3) mg w próbce metakrylan butylu (0,01 - 5) mg w próbce metylocykloheksan (0,01 - 15) mg w próbce 1-metoksypropan-2-ol (0,01 - 10) mg w próbce nafta (0,05 - 5) mg w próbce octan 2-butoksyetylu (0,01 - 5) mg w próbce dichlorometan (0,01 - 5) mg w próbce heptan (0,01 - 15) mg w próbce benzyna ekstrakcyjna (0,01 - 15) mg w próbce 4-metylopentan-2-on (0,01 - 5) mg w próbce, Zawartość trimetylobenzenów - mieszanina izomerów (1,2,3-, 1.2.4-, 1,3,5-) 1,3,5-trimetylobenzen (0,01- 5) mg w próbce 1,2,4-trimetylobenzen (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów i ich pochodnych aceton (0,01 - 15) mg w próbce pentan (0,01 - 15) mg w próbce octan metylu (0,01 - 15) mg w próbce butan-2-on (0,01 - 15) mg w próbce octan etylu (0,01 - 15) mg w próbce heksan (0,01 - 5) mg w próbce 2-metylopropan-1-ol (0,01 - 5) mg w próbce octan izopropylu (0,01 - 15) mg w próbce benzen (0,001 - 3) mg w próbce butan 1-ol (0,01 - 5) mg w próbce cykloheksan (0,01 - 15) mg w próbce metakrylan metylu (0,01 - 5) mg w próbce pentan-1-ol (0,01 - 5) mg w próbce toluen (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce tetrachloroeten (0,01 - 5) mg w próbce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w próbce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w próbce etylobenzen (0,01 - 5) mg w próbce ksylen-mieszanina izomerów: 1,2-;1,3; 1,4- (0,01 - 5) mg w próbce cykloheksanon (0,01 - 3) mg w próbce 2-butoksyetanol (0,01 - 5) mg w próbce styren (0,01 - 3) mg w próbce kumen (0,01 - 3) mg w próbce metakrylan butylu (0,01 - 5) mg w próbce metylocykloheksan (0,01 - 15) mg w próbce 1-metoksypropan-2-ol (0,01 - 10) mg w próbce nafta (0,05 - 5) mg w próbce octan 2-butoksyetylu (0,01 - 5) mg w próbce dichlorometan (0,01 - 5) mg w próbce heptan (0,01 - 15) mg w próbce benzyna ekstrakcyjna (0,01 - 15) mg w próbce 4-metylopentan-2-on (0,01 - 5) mg w próbce, Zawartość trimetylobenzenów - mieszanina izomerów (1,2,3-, 1.2.4-, 1,3,5-) 1,3,5-trimetylobenzen (0,01- 5) mg w próbce 1,2,4-trimetylobenzen (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EKOLAB/LB/PB-08 wydanie 7 z dnia 31.05.2019 r.","norm_bases":["EKOLAB/LB/PB-08 wydanie 7 z dnia 31.05.2019 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość węglowodorów i ich pochodnych aceton (0,01 - 15) mg w próbce pentan (0,01 - 15) mg w próbce octan metylu (0,01 - 15) mg w próbce butan-2-on (0,01 - 15) mg w próbce octan etylu (0,01 - 15) mg w próbce heksan (0,01 - 5) mg w próbce 2-metylopropan-1-ol (0,01 - 5) mg w próbce octan izopropylu (0,01 - 15) mg w próbce benzen (0,001 - 3) mg w próbce butan 1-ol (0,01 - 5) mg w próbce cykloheksan (0,01 - 15) mg w próbce metakrylan metylu (0,01 - 5) mg w próbce pentan-1-ol (0,01 - 5) mg w próbce toluen (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce tetrachloroeten (0,01 - 5) mg w próbce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w próbce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w próbce etylobenzen (0,01 - 5) mg w próbce ksylen-mieszanina izomerów: 1,2-;1,3; 1,4- (0,01 - 5) mg w próbce cykloheksanon (0,01 - 3) mg w próbce 2-butoksyetanol (0,01 - 5) mg w próbce styren (0,01 - 3) mg w próbce kumen (0,01 - 3) mg w próbce metakrylan butylu (0,01 - 5) mg w próbce metylocykloheksan (0,01 - 15) mg w próbce 1-metoksypropan-2-ol (0,01 - 10) mg w próbce nafta (0,05 - 5) mg w próbce octan 2-butoksyetylu (0,01 - 5) mg w próbce dichlorometan (0,01 - 5) mg w próbce heptan (0,01 - 15) mg w próbce benzyna ekstrakcyjna (0,01 - 15) mg w próbce 4-metylopentan-2-on (0,01 - 5) mg w próbce, Zawartość trimetylobenzenów - mieszanina izomerów (1,2,3-, 1.2.4-, 1,3,5-) 1,3,5-trimetylobenzen (0,01- 5) mg w próbce 1,2,4-trimetylobenzen (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EKOLAB/LB/PB-08 wydanie 7 z dnia 31.05.2019 r. Srodowisko pracy Zawartosc weglowodorow i ich pochodnych aceton (0,01 - 15) mg w probce pentan (0,01 - 15) mg w probce octan metylu (0,01 - 15) mg w probce butan-2-on (0,01 - 15) mg w probce octan etylu (0,01 - 15) mg w probce heksan (0,01 - 5) mg w probce 2-metylopropan-1-ol (0,01 - 5) mg w probce octan izopropylu (0,01 - 15) mg w probce benzen (0,001 - 3) mg w probce butan 1-ol (0,01 - 5) mg w probce cykloheksan (0,01 - 15) mg w probce metakrylan metylu (0,01 - 5) mg w probce pentan-1-ol (0,01 - 5) mg w probce toluen (0,01 - 5) mg w probce octan butylu (0,01 - 10) mg w probce tetrachloroeten (0,01 - 5) mg w probce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w probce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w probce etylobenzen (0,01 - 5) mg w probce ksylen-mieszanina izomerow: 1,2-;1,3; 1,4- (0,01 - 5) mg w probce cykloheksanon (0,01 - 3) mg w probce 2-butoksyetanol (0,01 - 5) mg w probce styren (0,01 - 3) mg w probce kumen (0,01 - 3) mg w probce metakrylan butylu (0,01 - 5) mg w probce metylocykloheksan (0,01 - 15) mg w probce 1-metoksypropan-2-ol (0,01 - 10) mg w probce nafta (0,05 - 5) mg w probce octan 2-butoksyetylu (0,01 - 5) mg w probce dichlorometan (0,01 - 5) mg w probce heptan (0,01 - 15) mg w probce benzyna ekstrakcyjna (0,01 - 15) mg w probce 4-metylopentan-2-on (0,01 - 5) mg w probce, Zawartosc trimetylobenzenow - mieszanina izomerow (1,2,3-, 1.2.4-, 1,3,5-) 1,3,5-trimetylobenzen (0,01- 5) mg w probce 1,2,4-trimetylobenzen (0,01 - 5) mg w probce 1,2,3-trimetylobenzen (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EKOLAB/LB/PB-08 wydanie 7 z dnia 31.05.2019 r.","categories":["environment","petro"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons and their derivatives acetone (0,01 - 15) mg in the sample pentane (0,01 - 15) mg in the sample methyl acetate (0,01 - 15) mg in the sample butan-2-one (0,01 - 15) mg in the sample ethyl acetate (0,01 - 15) mg in the sample hexane (0,01 - 5) mg in the sample 2-methylpropan-1-ol (0,01 - 5) mg in the sample isopropyl acetate (0,01 - 15) mg in the sample benzene (0,001 - 3) mg in the sample butan-1-ol (0,01 - 5) mg in the sample cyclohexane (0,01 - 15) mg in the sample methyl methacrylate (0,01 - 5) mg in the sample pentan-1-ol (0,01 - 5) mg in the sample toluene (0,01 - 5) mg in the sample butyl acetate (0,01 - 10) mg in the sample tetrachloroethene (0,01 - 5) mg in the sample 4-hydroxy-4-methylpentan-2-one (0,01 - 10) mg in the sample 2-methoxy-1-methylethyl acetate (0,01 - 10) mg in the sample ethylbenzene (0,01 - 5) mg in the sample xylene-mixture of isomers: 1,2-;1,3; 1,4- (0,01 - 5) mg in the sample cyclohexanone (0,01 - 3) mg in the sample 2-butoxyethanol (0,01 - 5) mg in the sample styrene (0,01 - 3) mg in the sample cumene (0,01 - 3) mg in the sample butyl methacrylate (0,01 - 5) mg in the sample methylcyclohexane (0,01 - 15) mg in the sample 1-methoxypropan-2-ol (0,01 - 10) mg in the sample kerosene (0,05 - 5) mg in the sample 2-butoxyethyl acetate (0,01 - 5) mg in the sample dichloromethane (0,01 - 5) mg in the sample heptane (0,01 - 15) mg in the sample extraction petrol (0,01 - 15) mg in the sample 4-methylpentan-2-one (0,01 - 5) mg in the sample, Content of trimethylbenzenes - mixture of isomers (1,2,3-, 1.2.4-, 1,3,5-) 1,3,5-trimethylbenzene (0,01- 5) mg in the sample 1,2,4-trimethylbenzene (0,01 - 5) mg in the sample 1,2,3-trimethylbenzene (0,01 - 5) mg in the sample","search_en":"Workplace environment Content of hydrocarbons and their derivatives acetone (0,01 - 15) mg in the sample pentane (0,01 - 15) mg in the sample methyl acetate (0,01 - 15) mg in the sample butan-2-one (0,01 - 15) mg in the sample ethyl acetate (0,01 - 15) mg in the sample hexane (0,01 - 5) mg in the sample 2-methylpropan-1-ol (0,01 - 5) mg in the sample isopropyl acetate (0,01 - 15) mg in the sample benzene (0,001 - 3) mg in the sample butan-1-ol (0,01 - 5) mg in the sample cyclohexane (0,01 - 15) mg in the sample methyl methacrylate (0,01 - 5) mg in the sample pentan-1-ol (0,01 - 5) mg in the sample toluene (0,01 - 5) mg in the sample butyl acetate (0,01 - 10) mg in the sample tetrachloroethene (0,01 - 5) mg in the sample 4-hydroxy-4-methylpentan-2-one (0,01 - 10) mg in the sample 2-methoxy-1-methylethyl acetate (0,01 - 10) mg in the sample ethylbenzene (0,01 - 5) mg in the sample xylene-mixture of isomers: 1,2-;1,3; 1,4- (0,01 - 5) mg in the sample cyclohexanone (0,01 - 3) mg in the sample 2-butoxyethanol (0,01 - 5) mg in the sample styrene (0,01 - 3) mg in the sample cumene (0,01 - 3) mg in the sample butyl methacrylate (0,01 - 5) mg in the sample methylcyclohexane (0,01 - 15) mg in the sample 1-methoxypropan-2-ol (0,01 - 10) mg in the sample kerosene (0,05 - 5) mg in the sample 2-butoxyethyl acetate (0,01 - 5) mg in the sample dichloromethane (0,01 - 5) mg in the sample heptane (0,01 - 15) mg in the sample extraction petrol (0,01 - 15) mg in the sample 4-methylpentan-2-one (0,01 - 5) mg in the sample, Content of trimethylbenzenes - mixture of isomers (1,2,3-, 1.2.4-, 1,3,5-) 1,3,5-trimethylbenzene (0,01- 5) mg in the sample 1,2,4-trimethylbenzene (0,01 - 5) mg in the sample 1,2,3-trimethylbenzene (0,01 - 5) mg in the sample Gas chromatography with flame ionization detection (GC-FID) EKOLAB/LB/PB-08 wydanie 7 z dnia 31.05.2019 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） EKOLAB/LB/PB-08 wydanie 7 z dnia 31.05.2019 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213a7","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość węglowodorów i ich pochodnych","parameters":[{"name":"aceton (0,01 - 15) mg w próbce butan 1-ol (0,01 - 5) mg w próbce"},{"name":"Zakres","range":"2-metylopropan-1-ol"},{"name":"Zakres","range":"(0,01 - 5) mg w próbce"},{"name":"toluen (0,01 - 5) mg w próbce ksylen-mieszanina izomerów: 1,2-;1,3-; 1,4- (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce octan etylu (0,01 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów i ich pochodnych\nZakres:\naceton (0,01 - 15) mg w próbce butan 1-ol (0,01 - 5) mg w próbce\nZakres 2-metylopropan-1-ol\nZakres (0,01 - 5) mg w próbce\ntoluen (0,01 - 5) mg w próbce ksylen-mieszanina izomerów: 1,2-;1,3-; 1,4- (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce octan etylu (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość węglowodorów i ich pochodnych\nZakres:\naceton (0,01 - 15) mg w próbce butan 1-ol (0,01 - 5) mg w próbce\nZakres 2-metylopropan-1-ol\nZakres (0,01 - 5) mg w próbce\ntoluen (0,01 - 5) mg w próbce ksylen-mieszanina izomerów: 1,2-;1,3-; 1,4- (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce octan etylu (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04023-02:1989 Srodowisko pracy Zawartosc weglowodorow i ich pochodnych\nZakres:\naceton (0,01 - 15) mg w probce butan 1-ol (0,01 - 5) mg w probce\nZakres 2-metylopropan-1-ol\nZakres (0,01 - 5) mg w probce\ntoluen (0,01 - 5) mg w probce ksylen-mieszanina izomerow: 1,2-;1,3-; 1,4- (0,01 - 5) mg w probce octan butylu (0,01 - 10) mg w probce octan etylu (0,01 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04023-02:1989","categories":["environment"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons and their derivatives","parameters_en":[{"name":"acetone (0,01 - 15) mg in the sample butan 1-ol (0,01 - 5) mg in the sample"},{"name":"Range","range":"2-metylopropan-1-ol"},{"name":"Range","range":"(0,01 - 5) mg w próbce"},{"name":"toluene (0,01 - 5) mg per sample xylene-mixture of isomers: 1,2-;1,3-; 1,4- (0,01 - 5) mg per sample butyl acetate (0,01 - 10) mg per sample ethyl acetate (0,01 - 15) mg per sample"}],"search_en":"Workplace environment Content of hydrocarbons and their derivatives Gas chromatography with flame ionization detection (GC-FID) acetone (0,01 - 15) mg in the sample butan 1-ol (0,01 - 5) mg in the sample Range Range toluene (0,01 - 5) mg per sample xylene-mixture of isomers: 1,2-;1,3-; 1,4- (0,01 - 5) mg per sample butyl acetate (0,01 - 10) mg per sample ethyl acetate (0,01 - 15) mg per sample PN-Z-04023-02:1989","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"aceton (0,01 - 15) mg w próbce butan 1-ol (0,01 - 5) mg w próbce"},{"name":"范围","range":"2-metylopropan-1-ol"},{"name":"范围","range":"(0,01 - 5) mg w próbce"},{"name":"toluen (0,01 - 5) mg w próbce ksylen-mieszanina izomerów: 1,2-;1,3-; 1,4- (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce octan etylu (0,01 - 15) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04023-02:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213a8","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość pentanu","parameters":[{"name":"Zakres","range":"(0,01 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość pentanu\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość pentanu\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Srodowisko pracy Zawartosc pentanu\nZakres (0,01 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["environment"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pentane content","parameters_en":[{"name":"Range","range":"(0,01 - 15) mg w próbce"}],"search_en":"Workplace environment Pentane content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04318:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 15) mg w próbce"}],"search_zh":"工作场所环境 戊烷含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境","methodology_zh":"戊烷含量"},{"_id":"6a83bcf4af14b9c0e7b213a9","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość octanu metylu","parameters":[{"name":"Zakres","range":"(0,01 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość octanu metylu\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-01:1978","norm_bases":["PN-Z-04119-01:1978"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość octanu metylu\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-01:1978 Srodowisko pracy Zawartosc octanu metylu\nZakres (0,01 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-01:1978","categories":["environment"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl acetate content","parameters_en":[{"name":"Range","range":"(0,01 - 15) mg w próbce"}],"search_en":"Workplace environment Methyl acetate content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04119-01:1978","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 15) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04119-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213aa","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość heksanu","parameters":[{"name":"Zakres","range":"(0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość heksanu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04136-3:2003","norm_bases":["PN-Z-04136-3:2003"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość heksanu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04136-3:2003 Srodowisko pracy Zawartosc heksanu\nZakres (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04136-3:2003","categories":["environment"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hexane content","parameters_en":[{"name":"Range","range":"(0,01 - 5) mg w próbce"}],"search_en":"Workplace environment Hexane content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04136-3:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 5) mg w próbce"}],"search_zh":"工作场所环境 正己烷含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04136-3:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境","methodology_zh":"正己烷含量"},{"_id":"6a83bcf4af14b9c0e7b213ab","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość octanu izopropylu","parameters":[{"name":"Zakres","range":"(0,01 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość octanu izopropylu\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-7:2006","norm_bases":["PN-Z-04119-7:2006"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość octanu izopropylu\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-7:2006 Srodowisko pracy Zawartosc octanu izopropylu\nZakres (0,01 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-7:2006","categories":["environment"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isopropyl acetate content","parameters_en":[{"name":"Range","range":"(0,01 - 15) mg w próbce"}],"search_en":"Workplace environment Isopropyl acetate content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04119-7:2006","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 15) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04119-7:2006","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213ac","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,001 - 3) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość benzenu\nZakres (0,001 - 3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość benzenu\nZakres (0,001 - 3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Srodowisko pracy Zawartosc benzenu\nZakres (0,001 - 3) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene content","parameters_en":[{"name":"Range","range":"(0,001 - 3) mg w próbce"}],"search_en":"Workplace environment Benzene content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04016-10:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,001 - 3) mg w próbce"}],"search_zh":"工作场所环境 苯含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境","methodology_zh":"苯含量"},{"_id":"6a83bcf4af14b9c0e7b213ad","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość tetrachloroetenu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04118-01:1978","norm_bases":["PN-Z-04118-01:1978"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość tetrachloroetenu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04118-01:1978 Srodowisko pracy Zawartosc tetrachloroetenu\nZakres (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04118-01:1978","categories":["environment"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Tetrachloroethene content","parameters_en":[{"name":"Range","range":"(0,01 - 5) mg w próbce"}],"search_en":"Workplace environment Tetrachloroethene content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04118-01:1978","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 5) mg w próbce"}],"search_zh":"工作场所环境 四氯乙烯含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04118-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境","methodology_zh":"四氯乙烯含量"},{"_id":"6a83bcf4af14b9c0e7b213ae","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość octanu 2-butoksyetylu","parameters":[{"name":"Zakres","range":"(0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość octanu 2-butoksyetylu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04304:2003","norm_bases":["PN-Z-04304:2003"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość octanu 2-butoksyetylu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04304:2003 Srodowisko pracy Zawartosc octanu 2-butoksyetylu\nZakres (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04304:2003","categories":["environment"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-butoxyethyl acetate content","parameters_en":[{"name":"Range","range":"(0,01 - 5) mg w próbce"}],"search_en":"Workplace environment 2-butoxyethyl acetate content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04304:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 5) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04304:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213af","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość dichlorometanu","parameters":[{"name":"Zakres","range":"(0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość dichlorometanu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04437:2011","norm_bases":["PN-Z-04437:2011"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość dichlorometanu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04437:2011 Srodowisko pracy Zawartosc dichlorometanu\nZakres (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04437:2011","categories":["environment"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dichloromethane content","parameters_en":[{"name":"Range","range":"(0,01 - 5) mg w próbce"}],"search_en":"Workplace environment Dichloromethane content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04437:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 5) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04437:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b0","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość trimetylobenzenów - mieszanina izomerów (1,2,3-, 1.2.4-, 1,3,5-)","parameters":[{"name":"Zakres","range":"1,2,4-trimetylobenzen"},{"name":"Zakres","range":"(0,01 - 5) mg w próbce"},{"name":"1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość trimetylobenzenów - mieszanina izomerów (1,2,3-, 1.2.4-, 1,3,5-)\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,01 - 5) mg w próbce\n1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-4:1998","norm_bases":["PN-Z-04016-4:1998"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość trimetylobenzenów - mieszanina izomerów (1,2,3-, 1.2.4-, 1,3,5-)\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,01 - 5) mg w próbce\n1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-4:1998 Srodowisko pracy Zawartosc trimetylobenzenow - mieszanina izomerow (1,2,3-, 1.2.4-, 1,3,5-)\nZakres:\nZakres 1,2,4-trimetylobenzen\nZakres (0,01 - 5) mg w probce\n1,3,5-trimetylobenzen (0,01 - 5) mg w probce 1,2,3-trimetylobenzen (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-4:1998","categories":["environment"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of trimethylbenzenes - mixture of isomers (1,2,3-, 1.2.4-, 1,3,5-)","parameters_en":[{"name":"Range","range":"1,2,4-trimetylobenzen"},{"name":"Range","range":"(0,01 - 5) mg w próbce"},{"name":"1,3,5-trimethylbenzene (0,01 - 5) mg in the sample 1,2,3-trimethylbenzene (0,01 - 5) mg in the sample"}],"search_en":"Workplace environment Content of trimethylbenzenes - mixture of isomers (1,2,3-, 1.2.4-, 1,3,5-) Gas chromatography with flame ionization detection (GC-FID) Range Range 1,3,5-trimethylbenzene (0,01 - 5) mg in the sample 1,2,3-trimethylbenzene (0,01 - 5) mg in the sample PN-Z-04016-4:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"1,2,4-trimetylobenzen"},{"name":"范围","range":"(0,01 - 5) mg w próbce"},{"name":"1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-4:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b1","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość 2-fenylopropanu (kumenu)","parameters":[{"name":"Zakres","range":"(0,01 - 3) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 2-fenylopropanu (kumenu)\nZakres (0,01 - 3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-6:1998","norm_bases":["PN-Z-04016-6:1998"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość 2-fenylopropanu (kumenu)\nZakres (0,01 - 3) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-6:1998 Srodowisko pracy Zawartosc 2-fenylopropanu (kumenu)\nZakres (0,01 - 3) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-6:1998","categories":["environment"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-phenylpropane (cumene) content","parameters_en":[{"name":"Range","range":"(0,01 - 3) mg w próbce"}],"search_en":"Workplace environment 2-phenylpropane (cumene) content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04016-6:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 3) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04016-6:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b2","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość metakrylanu butylu","parameters":[{"name":"Zakres","range":"(0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość metakrylanu butylu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04283:2001","norm_bases":["PN-Z-04283:2001"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość metakrylanu butylu\nZakres (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04283:2001 Srodowisko pracy Zawartosc metakrylanu butylu\nZakres (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04283:2001","categories":["environment"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Butyl methacrylate content","parameters_en":[{"name":"Range","range":"(0,01 - 5) mg w próbce"}],"search_en":"Workplace environment Butyl methacrylate content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04283:2001","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 5) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04283:2001","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b3","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,005 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość buta-1,3-dienu\nZakres (0,005 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-84/Z-04014-02","norm_bases":["PN-84/Z-04014-02"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość buta-1,3-dienu\nZakres (0,005 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-84/Z-04014-02 Srodowisko pracy Zawartosc buta-1,3-dienu\nZakres (0,005 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-84/Z-04014-02","categories":["environment"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Buta-1,3-diene content","parameters_en":[{"name":"Range","range":"(0,005 - 15) mg w próbce"}],"search_en":"Workplace environment Buta-1,3-diene content Gas chromatography with flame ionization detection (GC-FID) Range PN-84/Z-04014-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,005 - 15) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-84/Z-04014-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b4","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość benzyny do lakierów","parameters":[{"name":"Zakres","range":"(0,01 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość benzyny do lakierów\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04211-02","norm_bases":["PN-89/Z-04211-02"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość benzyny do lakierów\nZakres (0,01 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04211-02 Srodowisko pracy Zawartosc benzyny do lakierow\nZakres (0,01 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04211-02","categories":["environment","automotive"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"White spirit content","parameters_en":[{"name":"Range","range":"(0,01 - 15) mg w próbce"}],"search_en":"Workplace environment White spirit content Gas chromatography with flame ionization detection (GC-FID) Range PN-89/Z-04211-02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 15) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-89/Z-04211-02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b5","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość 2-etoksyetanolu","parameters":[{"name":"Zakres","range":"(0,01 - 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 2-etoksyetanolu\nZakres (0,01 - 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1(63)","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1(63)"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość 2-etoksyetanolu\nZakres (0,01 - 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1(63) Srodowisko pracy Zawartosc 2-etoksyetanolu\nZakres (0,01 - 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2010, nr 1(63)","categories":["environment"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-ethoxyethanol content","parameters_en":[{"name":"Range","range":"(0,01 - 10) mg w próbce"}],"search_en":"Workplace environment 2-ethoxyethanol content Gas chromatography with flame ionization detection (GC-FID) Range Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1(63)","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,01 - 10) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1(63)","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b6","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość 2-(-2butoksyetoksy)etanolu","parameters":[{"name":"Zakres","range":"(0,05 - 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 2-(-2butoksyetoksy)etanolu\nZakres (0,05 - 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2004, nr 4(42)","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2004, nr 4(42)"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość 2-(-2butoksyetoksy)etanolu\nZakres (0,05 - 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2004, nr 4(42) Srodowisko pracy Zawartosc 2-(-2butoksyetoksy)etanolu\nZakres (0,05 - 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2004, nr 4(42)","categories":["environment"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-(-2butoxyethoxy)ethanol content","parameters_en":[{"name":"Range","range":"(0,05 - 10) mg w próbce"}],"search_en":"Workplace environment 2-(-2butoxyethoxy)ethanol content Gas chromatography with flame ionization detection (GC-FID) Range Podstawy i Metody Oceny Środowiska Pracy 2004, nr 4(42)","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,05 - 10) mg w próbce"}],"search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） 范围 Podstawy i Metody Oceny Środowiska Pracy 2004, nr 4(42)","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213b7","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,001 - 0,050) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną"],"computed":[],"activity":"Zawartość tlenku azotu\nZakres (0,001 - 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną","reference":"Metodyka OSHA Technical Center Salt Lake City, nr ID-190, maj 1991","norm_bases":["Metodyka OSHA Technical Center Salt Lake City, nr ID-190, maj 1991"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość tlenku azotu\nZakres (0,001 - 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną Metodyka OSHA Technical Center Salt Lake City, nr ID-190, maj 1991 Srodowisko pracy Zawartosc tlenku azotu\nZakres (0,001 - 0,050) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna Metodyka OSHA Technical Center Salt Lake City, nr ID-190, maj 1991","categories":["environment"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen oxide content","parameters_en":[{"name":"Range","range":"(0,001 - 0,050) mg w próbce"}],"search_en":"Workplace environment Nitrogen oxide content Ion chromatography with conductometric detection Range Metodyka OSHA Technical Center Salt Lake City, nr ID-190, maj 1991","technique_en":"Ion chromatography with conductometric detection","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,001 - 0,050) mg w próbce"}],"search_zh":"工作场所环境 一氧化氮含量 离子色谱-电导检测法 范围 Metodyka OSHA Technical Center Salt Lake City, nr ID-190, maj 1991","test_object_zh":"工作场所环境","technique_zh":"离子色谱-电导检测法","methodology_zh":"一氧化氮含量"},{"_id":"6a83bcf4af14b9c0e7b213b8","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,0005 - 0,050) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną"],"computed":[],"activity":"Zawartość ditlenku azotu\nZakres (0,0005 - 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną","reference":"Metodyka OSHA Technical Center Salt Lake City, nr ID-182, maj 1991","norm_bases":["Metodyka OSHA Technical Center Salt Lake City, nr ID-182, maj 1991"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość ditlenku azotu\nZakres (0,0005 - 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną Metodyka OSHA Technical Center Salt Lake City, nr ID-182, maj 1991 Srodowisko pracy Zawartosc ditlenku azotu\nZakres (0,0005 - 0,050) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna Metodyka OSHA Technical Center Salt Lake City, nr ID-182, maj 1991","categories":["environment"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide content","parameters_en":[{"name":"Range","range":"(0,0005 - 0,050) mg w próbce"}],"search_en":"Workplace environment Nitrogen dioxide content Ion chromatography with conductometric detection Range Metodyka OSHA Technical Center Salt Lake City, nr ID-182, maj 1991","technique_en":"Ion chromatography with conductometric detection","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,0005 - 0,050) mg w próbce"}],"search_zh":"工作场所环境 二氧化氮含量 离子色谱-电导检测法 范围 Metodyka OSHA Technical Center Salt Lake City, nr ID-182, maj 1991","test_object_zh":"工作场所环境","technique_zh":"离子色谱-电导检测法","methodology_zh":"二氧化氮含量"},{"_id":"6a83bcf4af14b9c0e7b213b9","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne","methodology":"Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,008 - 2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość amoniaku\nZakres (0,008 - 2) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 21877:2020-03","norm_bases":["PN-EN 21877:2020-03"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne Zawartość amoniaku\nZakres (0,008 - 2) mg w próbce\nMetoda spektrofotometryczna PN-EN 21877:2020-03 Srodowisko ogolne Zawartosc amoniaku\nZakres (0,008 - 2) mg w probce\nMetoda spektrofotometryczna PN-EN 21877:2020-03","categories":["environment"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia content","parameters_en":[{"name":"Range","range":"(0,008 - 2) mg w próbce"}],"search_en":"General environment Ammonia content Spectrophotometric method Range PN-EN 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"General environment","parameters_zh":[{"name":"范围","range":"(0,008 - 2) mg w próbce"}],"search_zh":"一般环境 氨含量 分光光度法 范围 PN-EN 21877:2020-03","technique_zh":"分光光度法","methodology_zh":"氨含量","test_object_zh":"一般环境"},{"_id":"6a83bcf4af14b9c0e7b213ba","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość węglowodorów i ich pochodnych","parameters":[{"name":"ksyleny (0,01 - 5) mg w próbce cykloheksanon (0,01 - 3) mg w próbce"},{"name":"Zakres","range":"2-butoksyetanol (0,01 - 5) mg w próbce"},{"name":"styren (0,01 - 3) mg w próbce kumen (0,01 - 3) mg w próbce fenylopropan (0,01 - 5) mg w próbce metakrylan butylu (0,01 - 5) mg w próbce 1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,4-trimetylobenzen (0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów i ich pochodnych\nZakres:\nksyleny (0,01 - 5) mg w próbce cykloheksanon (0,01 - 3) mg w próbce\nZakres 2-butoksyetanol (0,01 - 5) mg w próbce\nstyren (0,01 - 3) mg w próbce kumen (0,01 - 3) mg w próbce fenylopropan (0,01 - 5) mg w próbce metakrylan butylu (0,01 - 5) mg w próbce 1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,4-trimetylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość węglowodorów i ich pochodnych\nZakres:\nksyleny (0,01 - 5) mg w próbce cykloheksanon (0,01 - 3) mg w próbce\nZakres 2-butoksyetanol (0,01 - 5) mg w próbce\nstyren (0,01 - 3) mg w próbce kumen (0,01 - 3) mg w próbce fenylopropan (0,01 - 5) mg w próbce metakrylan butylu (0,01 - 5) mg w próbce 1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,4-trimetylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne - probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc weglowodorow i ich pochodnych\nZakres:\nksyleny (0,01 - 5) mg w probce cykloheksanon (0,01 - 3) mg w probce\nZakres 2-butoksyetanol (0,01 - 5) mg w probce\nstyren (0,01 - 3) mg w probce kumen (0,01 - 3) mg w probce fenylopropan (0,01 - 5) mg w probce metakrylan butylu (0,01 - 5) mg w probce 1,3,5-trimetylobenzen (0,01 - 5) mg w probce 1,2,4-trimetylobenzen (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons and their derivatives","parameters_en":[{"name":"xylenes (0,01 - 5) mg in sample cyclohexanone (0,01 - 3) mg in sample"},{"name":"Range","range":"2-butoksyetanol (0,01 - 5) mg w próbce"},{"name":"styrene (0,01 - 3) mg per sample cumene (0,01 - 3) mg per sample phenylpropane (0,01 - 5) mg per sample butyl methacrylate (0,01 - 5) mg per sample 1,3,5-trimethylbenzene (0,01 - 5) mg per sample 1,2,4-trimethylbenzene (0,01 - 5) mg per sample"}],"search_en":"General environment - waste gas samples collected on sorbent tubes Content of hydrocarbons and their derivatives Gas chromatography with flame ionization detection (GC-FID) xylenes (0,01 - 5) mg in sample cyclohexanone (0,01 - 3) mg in sample Range styrene (0,01 - 3) mg per sample cumene (0,01 - 3) mg per sample phenylpropane (0,01 - 5) mg per sample butyl methacrylate (0,01 - 5) mg per sample 1,3,5-trimethylbenzene (0,01 - 5) mg per sample 1,2,4-trimethylbenzene (0,01 - 5) mg per sample PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment - waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"ksyleny (0,01 - 5) mg w próbce cykloheksanon (0,01 - 3) mg w próbce"},{"name":"范围","range":"2-butoksyetanol (0,01 - 5) mg w próbce"},{"name":"styren (0,01 - 3) mg w próbce kumen (0,01 - 3) mg w próbce fenylopropan (0,01 - 5) mg w próbce metakrylan butylu (0,01 - 5) mg w próbce 1,3,5-trimetylobenzen (0,01 - 5) mg w próbce 1,2,4-trimetylobenzen (0,01 - 5) mg w próbce"}],"search_zh":"一般环境 － 采集于吸附管中的排放气体样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 － 采集于吸附管中的排放气体样品"},{"_id":"6a83bcf4af14b9c0e7b213bb","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość węglowodorów i ich pochodnych","parameters":[{"name":"octan 2-butoksyetylu"},{"name":"Zakres","range":"(0,01 - 5) mg w próbce"},{"name":"dichlorometan (0,01 - 5) mg w próbce 3-metylobutan-1-ol (0,01 - 5) mg w próbce 1-chloro-2,3-epoksypropan (0,01 - 5) mg w próbce benzyna ekstrakcyjna (0,01 - 15) mg w próbce 4-metylopentan-2-on (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce heptan (0,01 - 15) mg w próbce aceton (0,01 - 15) mg w próbce pentan (0,01 - 15) mg w próbce octan metylu (0,01 - 15) mg w próbce butan-2-on (0,01 - 15) mg w próbce octan etylu (0,01 - 15) mg w próbce heksan (0,01 - 5) mg w próbce 2-metylopropan-1-ol (0,01 - 5) mg w próbce octan izopropylu (0,01 - 15) mg w próbce benzen (0,001 - 3) mg w próbce butan 1-ol (0,01 - 5) mg w próbce cykloheksan (0,01 - 15) mg w próbce metakrylan metylu (0,01 - 5) mg w próbce pentan-1-ol (0,01 - 5) mg w próbce toluen (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce tetrachloroeten (0,01 - 5) mg w próbce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w próbce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w próbce etylobenzen (0,01 - 5) mg w próbce"},{"name":"etylobenzen","range":"(0,01 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów i ich pochodnych\nZakres:\noctan 2-butoksyetylu\nZakres (0,01 - 5) mg w próbce\ndichlorometan (0,01 - 5) mg w próbce 3-metylobutan-1-ol (0,01 - 5) mg w próbce 1-chloro-2,3-epoksypropan (0,01 - 5) mg w próbce benzyna ekstrakcyjna (0,01 - 15) mg w próbce 4-metylopentan-2-on (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce heptan (0,01 - 15) mg w próbce aceton (0,01 - 15) mg w próbce pentan (0,01 - 15) mg w próbce octan metylu (0,01 - 15) mg w próbce butan-2-on (0,01 - 15) mg w próbce octan etylu (0,01 - 15) mg w próbce heksan (0,01 - 5) mg w próbce 2-metylopropan-1-ol (0,01 - 5) mg w próbce octan izopropylu (0,01 - 15) mg w próbce benzen (0,001 - 3) mg w próbce butan 1-ol (0,01 - 5) mg w próbce cykloheksan (0,01 - 15) mg w próbce metakrylan metylu (0,01 - 5) mg w próbce pentan-1-ol (0,01 - 5) mg w próbce toluen (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce tetrachloroeten (0,01 - 5) mg w próbce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w próbce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w próbce etylobenzen (0,01 - 5) mg w próbce\netylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość węglowodorów i ich pochodnych\nZakres:\noctan 2-butoksyetylu\nZakres (0,01 - 5) mg w próbce\ndichlorometan (0,01 - 5) mg w próbce 3-metylobutan-1-ol (0,01 - 5) mg w próbce 1-chloro-2,3-epoksypropan (0,01 - 5) mg w próbce benzyna ekstrakcyjna (0,01 - 15) mg w próbce 4-metylopentan-2-on (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce heptan (0,01 - 15) mg w próbce aceton (0,01 - 15) mg w próbce pentan (0,01 - 15) mg w próbce octan metylu (0,01 - 15) mg w próbce butan-2-on (0,01 - 15) mg w próbce octan etylu (0,01 - 15) mg w próbce heksan (0,01 - 5) mg w próbce 2-metylopropan-1-ol (0,01 - 5) mg w próbce octan izopropylu (0,01 - 15) mg w próbce benzen (0,001 - 3) mg w próbce butan 1-ol (0,01 - 5) mg w próbce cykloheksan (0,01 - 15) mg w próbce metakrylan metylu (0,01 - 5) mg w próbce pentan-1-ol (0,01 - 5) mg w próbce toluen (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce tetrachloroeten (0,01 - 5) mg w próbce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w próbce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w próbce etylobenzen (0,01 - 5) mg w próbce\netylobenzen (0,01 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Srodowisko ogolne - probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc weglowodorow i ich pochodnych\nZakres:\noctan 2-butoksyetylu\nZakres (0,01 - 5) mg w probce\ndichlorometan (0,01 - 5) mg w probce 3-metylobutan-1-ol (0,01 - 5) mg w probce 1-chloro-2,3-epoksypropan (0,01 - 5) mg w probce benzyna ekstrakcyjna (0,01 - 15) mg w probce 4-metylopentan-2-on (0,01 - 5) mg w probce 1,2,3-trimetylobenzen (0,01 - 5) mg w probce heptan (0,01 - 15) mg w probce aceton (0,01 - 15) mg w probce pentan (0,01 - 15) mg w probce octan metylu (0,01 - 15) mg w probce butan-2-on (0,01 - 15) mg w probce octan etylu (0,01 - 15) mg w probce heksan (0,01 - 5) mg w probce 2-metylopropan-1-ol (0,01 - 5) mg w probce octan izopropylu (0,01 - 15) mg w probce benzen (0,001 - 3) mg w probce butan 1-ol (0,01 - 5) mg w probce cykloheksan (0,01 - 15) mg w probce metakrylan metylu (0,01 - 5) mg w probce pentan-1-ol (0,01 - 5) mg w probce toluen (0,01 - 5) mg w probce octan butylu (0,01 - 10) mg w probce tetrachloroeten (0,01 - 5) mg w probce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w probce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w probce etylobenzen (0,01 - 5) mg w probce\netylobenzen (0,01 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["environment","petro"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of hydrocarbons and their derivatives","parameters_en":[{"name":"2-butoxyethyl acetate"},{"name":"Range","range":"(0,01 - 5) mg w próbce"},{"name":"dichloromethane (0,01 - 5) mg in sample 3-methylbutan-1-ol (0,01 - 5) mg in sample 1-chloro-2,3-epoxypropane (0,01 - 5) mg in sample extraction naphtha (0,01 - 15) mg in sample 4-methylpentan-2-one (0,01 - 5) mg in sample 1,2,3-trimethylbenzene (0,01 - 5) mg in sample heptane (0,01 - 15) mg in sample acetone (0,01 - 15) mg in sample pentane (0,01 - 15) mg in sample methyl acetate (0,01 - 15) mg in sample butan-2-one (0,01 - 15) mg in sample ethyl acetate (0,01 - 15) mg in sample hexane (0,01 - 5) mg in sample 2-methylpropan-1-ol (0,01 - 5) mg in sample isopropyl acetate (0,01 - 15) mg in sample benzene (0,001 - 3) mg in sample butan 1-ol (0,01 - 5) mg in sample cyclohexane (0,01 - 15) mg in sample methyl methacrylate (0,01 - 5) mg in sample pentan-1-ol (0,01 - 5) mg in sample toluene (0,01 - 5) mg in sample butyl acetate (0,01 - 10) mg in sample tetrachloroethene (0,01 - 5) mg in sample 4-hydroxy-4-methylpentan-2-one (0,01 - 10) mg in sample 2-methoxy-1-methylethyl acetate (0,01 - 10) mg in sample ethylbenzene (0,01 - 5) mg in sample"},{"name":"ethylbenzene","range":"(0,01 - 5) mg w próbce"}],"search_en":"General environment - waste gas samples collected on sorbent tubes Content of hydrocarbons and their derivatives Gas chromatography with flame ionization detection (GC-FID) 2-butoxyethyl acetate Range dichloromethane (0,01 - 5) mg in sample 3-methylbutan-1-ol (0,01 - 5) mg in sample 1-chloro-2,3-epoxypropane (0,01 - 5) mg in sample extraction naphtha (0,01 - 15) mg in sample 4-methylpentan-2-one (0,01 - 5) mg in sample 1,2,3-trimethylbenzene (0,01 - 5) mg in sample heptane (0,01 - 15) mg in sample acetone (0,01 - 15) mg in sample pentane (0,01 - 15) mg in sample methyl acetate (0,01 - 15) mg in sample butan-2-one (0,01 - 15) mg in sample ethyl acetate (0,01 - 15) mg in sample hexane (0,01 - 5) mg in sample 2-methylpropan-1-ol (0,01 - 5) mg in sample isopropyl acetate (0,01 - 15) mg in sample benzene (0,001 - 3) mg in sample butan 1-ol (0,01 - 5) mg in sample cyclohexane (0,01 - 15) mg in sample methyl methacrylate (0,01 - 5) mg in sample pentan-1-ol (0,01 - 5) mg in sample toluene (0,01 - 5) mg in sample butyl acetate (0,01 - 10) mg in sample tetrachloroethene (0,01 - 5) mg in sample 4-hydroxy-4-methylpentan-2-one (0,01 - 10) mg in sample 2-methoxy-1-methylethyl acetate (0,01 - 10) mg in sample ethylbenzene (0,01 - 5) mg in sample ethylbenzene PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment - waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"乙二醇丁醚醋酸酯"},{"name":"范围","range":"(0,01 - 5) mg w próbce"},{"name":"dichlorometan (0,01 - 5) mg w próbce 3-metylobutan-1-ol (0,01 - 5) mg w próbce 1-chloro-2,3-epoksypropan (0,01 - 5) mg w próbce benzyna ekstrakcyjna (0,01 - 15) mg w próbce 4-metylopentan-2-on (0,01 - 5) mg w próbce 1,2,3-trimetylobenzen (0,01 - 5) mg w próbce heptan (0,01 - 15) mg w próbce aceton (0,01 - 15) mg w próbce pentan (0,01 - 15) mg w próbce octan metylu (0,01 - 15) mg w próbce butan-2-on (0,01 - 15) mg w próbce octan etylu (0,01 - 15) mg w próbce heksan (0,01 - 5) mg w próbce 2-metylopropan-1-ol (0,01 - 5) mg w próbce octan izopropylu (0,01 - 15) mg w próbce benzen (0,001 - 3) mg w próbce butan 1-ol (0,01 - 5) mg w próbce cykloheksan (0,01 - 15) mg w próbce metakrylan metylu (0,01 - 5) mg w próbce pentan-1-ol (0,01 - 5) mg w próbce toluen (0,01 - 5) mg w próbce octan butylu (0,01 - 10) mg w próbce tetrachloroeten (0,01 - 5) mg w próbce 4-hydroksy-4-metylopentan-2-on (0,01 - 10) mg w próbce octan 2-metoksy-1-metyloetylu (0,01 - 10) mg w próbce etylobenzen (0,01 - 5) mg w próbce"},{"name":"乙苯","range":"(0,01 - 5) mg w próbce"}],"search_zh":"一般环境 － 采集于吸附管中的排放气体样品 气相色谱-氢火焰离子化检测法（GC-FID） 乙二醇丁醚醋酸酯 范围 乙苯 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 － 采集于吸附管中的排放气体样品"},{"_id":"6a83bcf4af14b9c0e7b213bc","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość rtęci, par i jej związków nieorganicznych w przeliczeniu na Hg","parameters":[{"name":"Zakres","range":"(0,025 – 6,0) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci, par i jej związków nieorganicznych w przeliczeniu na Hg\nZakres (0,025 – 6,0) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-Z-04332:2006 Metodyka OSHA Technical Center Salt Lake City nr ID-145, grudzień 1989","norm_bases":["PN-Z-04332:2006 Metodyka OSHA Technical Center Salt Lake City nr ID-145, grudzień 1989"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość rtęci, par i jej związków nieorganicznych w przeliczeniu na Hg\nZakres (0,025 – 6,0) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-Z-04332:2006 Metodyka OSHA Technical Center Salt Lake City nr ID-145, grudzień 1989 Srodowisko pracy Zawartosc rteci, par i jej zwiazkow nieorganicznych w przeliczeniu na Hg\nZakres (0,025 – 6,0) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-Z-04332:2006 Metodyka OSHA Technical Center Salt Lake City nr ID-145, grudzien 1989","categories":["environment"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of mercury, vapour and its inorganic compounds expressed as Hg","parameters_en":[{"name":"Range","range":"(0,025 – 6,0) μg w próbce"}],"search_en":"Workplace environment Content of mercury, vapour and its inorganic compounds expressed as Hg Cold vapour atomic absorption spectrometry (CVAAS) Range PN-Z-04332:2006 Metodyka OSHA Technical Center Salt Lake City nr ID-145, grudzień 1989","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,025 – 6,0) μg w próbce"}],"search_zh":"工作场所环境 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-Z-04332:2006 Metodyka OSHA Technical Center Salt Lake City nr ID-145, grudzień 1989","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213bd","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(0,005 - 2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość glikolu etylenowego\nZakres (0,005 - 2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EKOLAB/LB/PB-136 wydanie 3 z dnia 06.05.2011 r.","norm_bases":["EKOLAB/LB/PB-136 wydanie 3 z dnia 06.05.2011 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość glikolu etylenowego\nZakres (0,005 - 2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EKOLAB/LB/PB-136 wydanie 3 z dnia 06.05.2011 r. Srodowisko pracy Zawartosc glikolu etylenowego\nZakres (0,005 - 2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EKOLAB/LB/PB-136 wydanie 3 z dnia 06.05.2011 r.","categories":["environment"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylene glycol content","parameters_en":[{"name":"Range","range":"(0,005 - 2) mg w próbce"}],"search_en":"Workplace environment Ethylene glycol content Gas chromatography with flame ionization detection (GC-FID) Range EKOLAB/LB/PB-136 wydanie 3 z dnia 06.05.2011 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,005 - 2) mg w próbce"}],"search_zh":"工作场所环境 乙二醇含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 EKOLAB/LB/PB-136 wydanie 3 z dnia 06.05.2011 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境","methodology_zh":"乙二醇含量"},{"_id":"6a83bcf4af14b9c0e7b213be","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(0,002 - 1,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość kwasu octowego\nZakres (0,002 - 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość kwasu octowego\nZakres (0,002 - 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04323:2004 Srodowisko pracy Zawartosc kwasu octowego\nZakres (0,002 - 1,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04323:2004","categories":["environment"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acetic acid content","parameters_en":[{"name":"Range","range":"(0,002 - 1,5) mg w próbce"}],"search_en":"Workplace environment Acetic acid content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04323:2004","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,002 - 1,5) mg w próbce"}],"search_zh":"工作场所环境 乙酸含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04323:2004","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境","methodology_zh":"乙酸含量"},{"_id":"6a83bcf4af14b9c0e7b213bf","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość 1-metylo-2-pirolidonu","parameters":[{"name":"Zakres","range":"(0,002 - 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość 1-metylo-2-pirolidonu\nZakres (0,002 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EKOLAB/LB/PB-169 wydanie 1 z dnia 25.01.2011 r.","norm_bases":["EKOLAB/LB/PB-169 wydanie 1 z dnia 25.01.2011 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość 1-metylo-2-pirolidonu\nZakres (0,002 - 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EKOLAB/LB/PB-169 wydanie 1 z dnia 25.01.2011 r. Srodowisko pracy Zawartosc 1-metylo-2-pirolidonu\nZakres (0,002 - 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EKOLAB/LB/PB-169 wydanie 1 z dnia 25.01.2011 r.","categories":["environment"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"1-methyl-2-pyrrolidone content","parameters_en":[{"name":"Range","range":"(0,002 - 15) mg w próbce"}],"search_en":"Workplace environment 1-methyl-2-pyrrolidone content Gas chromatography with flame ionization detection (GC-FID) Range EKOLAB/LB/PB-169 wydanie 1 z dnia 25.01.2011 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","parameters_zh":[{"name":"范围","range":"(0,002 - 15) mg w próbce"}],"search_zh":"工作场所环境 1-甲基-2-吡咯烷酮含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 EKOLAB/LB/PB-169 wydanie 1 z dnia 25.01.2011 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境","methodology_zh":"1-甲基-2-吡咯烷酮含量"},{"_id":"6a83bcf4af14b9c0e7b213c0","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Zawartość metanolu, etanolu, propan-2-olu, propan-1-olu","parameters":[{"name":"metanol (0,01 - 10) mg w próbce etanol (0,01 - 10) mg w próbce propan-2-ol (0,01- 10) mg w próbce propan-1-ol (0,01- 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość metanolu, etanolu, propan-2-olu, propan-1-olu\nmetanol (0,01 - 10) mg w próbce etanol (0,01 - 10) mg w próbce propan-2-ol (0,01- 10) mg w próbce propan-1-ol (0,01- 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"EKOLAB/LB/PB-171 wydanie 2 z dnia 25.08.2015 r.","norm_bases":["EKOLAB/LB/PB-171 wydanie 2 z dnia 25.08.2015 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Zawartość metanolu, etanolu, propan-2-olu, propan-1-olu\nmetanol (0,01 - 10) mg w próbce etanol (0,01 - 10) mg w próbce propan-2-ol (0,01- 10) mg w próbce propan-1-ol (0,01- 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) EKOLAB/LB/PB-171 wydanie 2 z dnia 25.08.2015 r. Srodowisko pracy Zawartosc metanolu, etanolu, propan-2-olu, propan-1-olu\nmetanol (0,01 - 10) mg w probce etanol (0,01 - 10) mg w probce propan-2-ol (0,01- 10) mg w probce propan-1-ol (0,01- 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) EKOLAB/LB/PB-171 wydanie 2 z dnia 25.08.2015 r.","categories":["environment"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol, ethanol, propan-2-ol, propan-1-ol content","parameters_en":[{"name":"methanol (0,01 - 10) mg in sample ethanol (0,01 - 10) mg in sample propan-2-ol (0,01- 10) mg in sample propan-1-ol (0,01- 10) mg in sample"}],"search_en":"Workplace environment Methanol, ethanol, propan-2-ol, propan-1-ol content Gas chromatography with flame ionization detection (GC-FID) methanol (0,01 - 10) mg in sample ethanol (0,01 - 10) mg in sample propan-2-ol (0,01- 10) mg in sample propan-1-ol (0,01- 10) mg in sample EKOLAB/LB/PB-171 wydanie 2 z dnia 25.08.2015 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment","search_zh":"工作场所环境 气相色谱-氢火焰离子化检测法（GC-FID） EKOLAB/LB/PB-171 wydanie 2 z dnia 25.08.2015 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213c1","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego","methodology":"Zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,001 - 0,01) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość ozonu\nZakres (0,001 - 0,01) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane do roztworu pochłaniającego Zawartość ozonu\nZakres (0,001 - 0,01) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko ogolne - probki gazow odlotowych pobrane do roztworu pochlaniajacego Zawartosc ozonu\nZakres (0,001 - 0,01) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone content","parameters_en":[{"name":"Range","range":"(0,001 - 0,01) mg w próbce"}],"search_en":"General environment - waste gas samples collected into absorbing solution Ozone content Spectrophotometric method Range PN-Z-04007-2:1994","technique_en":"Spectrophotometric method","test_object_en":"General environment - waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,001 - 0,01) mg w próbce"}],"search_zh":"一般环境 — 采集于吸收液的废气样品 臭氧含量 分光光度法 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","test_object_zh":"一般环境 — 采集于吸收液的废气样品","methodology_zh":"臭氧含量"},{"_id":"6a83bcf4af14b9c0e7b213c2","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,2 - 200) μg w próbce"},{"name":"Zawartość rtęci"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres:\nZakres (0,2 - 200) μg w próbce\nZawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne Zawartość rtęci\nZakres:\nZakres (0,2 - 200) μg w próbce\nZawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006 Srodowisko ogolne Zawartosc rteci\nZakres:\nZakres (0,2 - 200) μg w probce\nZawartosc rteci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006","categories":["environment"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,2 - 200) μg w próbce"},{"name":"Mercury content"}],"search_en":"General environment Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range Mercury content PN-EN 13211+AC:2006","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"General environment","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,2 - 200) μg w próbce"},{"name":"汞含量"}],"search_zh":"一般环境 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 汞含量 PN-EN 13211+AC:2006","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"一般环境"},{"_id":"6a83bcf4af14b9c0e7b213c3","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne","methodology":"Zawartość:","parameters":[{"name":"metylenobis(fenyloizocyjanianu)"},{"name":"Zakres","range":"(0,00050 - 0,015) mg w próbce"},{"name":"diizocyjanianu tolueno-2,4-diylu"},{"name":"Zakres","range":"(0,000075 - 0,0075) mg w"},{"name":"próbce"},{"name":"diizocyjanianu tolueno-2,6-diylu"},{"name":"Zakres","range":"(0,000075 - 0,0075) mg w"},{"name":"próbce"},{"name":"diizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)"},{"name":"Zakres","range":"(0,00050 - 0,025) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD"],"computed":[],"activity":"Zawartość:\nZakres:\nmetylenobis(fenyloizocyjanianu)\nZakres (0,00050 - 0,015) mg w próbce\ndiizocyjanianu tolueno-2,4-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu tolueno-2,6-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)\nZakres (0,00050 - 0,025) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD","reference":"EKOLAB/LB/PB-212 wydanie 2 z dnia 05.11.2025 r.","norm_bases":["EKOLAB/LB/PB-212 wydanie 2 z dnia 05.11.2025 r."],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne Zawartość:\nZakres:\nmetylenobis(fenyloizocyjanianu)\nZakres (0,00050 - 0,015) mg w próbce\ndiizocyjanianu tolueno-2,4-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu tolueno-2,6-diylu\nZakres (0,000075 - 0,0075) mg w\npróbce\ndiizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)\nZakres (0,00050 - 0,025) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD EKOLAB/LB/PB-212 wydanie 2 z dnia 05.11.2025 r. Srodowisko ogolne Zawartosc:\nZakres:\nmetylenobis(fenyloizocyjanianu)\nZakres (0,00050 - 0,015) mg w probce\ndiizocyjanianu tolueno-2,4-diylu\nZakres (0,000075 - 0,0075) mg w\nprobce\ndiizocyjanianu tolueno-2,6-diylu\nZakres (0,000075 - 0,0075) mg w\nprobce\ndiizocyjanianu heksano-1,6-diylu (szesciometylenodwuizocyjanianu)\nZakres (0,00050 - 0,025) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD EKOLAB/LB/PB-212 wydanie 2 z dnia 05.11.2025 r.","categories":["environment"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content:","parameters_en":[{"name":"methylenebis(phenyl isocyanate)"},{"name":"Range","range":"(0,00050 - 0,015) mg w próbce"},{"name":"toluene-2,4-diyl diisocyanate"},{"name":"Range","range":"(0,000075 - 0,0075) mg w"},{"name":"sample"},{"name":"toluene-2,6-diyl diisocyanate"},{"name":"Range","range":"(0,000075 - 0,0075) mg w"},{"name":"sample"},{"name":"hexane-1,6-diyl diisocyanate (hexamethylene diisocyanate)"},{"name":"Range","range":"(0,00050 - 0,025) mg w próbce"}],"search_en":"General environment Content: High-performance liquid chromatography with fluorescence detection (HPLC-FLD methylenebis(phenyl isocyanate) Range toluene-2,4-diyl diisocyanate Range sample toluene-2,6-diyl diisocyanate Range sample hexane-1,6-diyl diisocyanate (hexamethylene diisocyanate) Range EKOLAB/LB/PB-212 wydanie 2 z dnia 05.11.2025 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD","test_object_en":"General environment","parameters_zh":[{"name":"metylenobis(fenyloizocyjanianu)"},{"name":"范围","range":"(0,00050 - 0,015) mg w próbce"},{"name":"甲苯-2,4-二异氰酸酯"},{"name":"范围","range":"(0,000075 - 0,0075) mg w"},{"name":"样品中"},{"name":"甲苯-2,6-二异氰酸酯"},{"name":"范围","range":"(0,000075 - 0,0075) mg w"},{"name":"样品中"},{"name":"diizocyjanianu heksano-1,6-diylu (sześciometylenodwuizocyjanianu)"},{"name":"范围","range":"(0,00050 - 0,025) mg w próbce"}],"search_zh":"一般环境 含量： 范围 甲苯-2,4-二异氰酸酯 范围 样品中 甲苯-2,6-二异氰酸酯 范围 样品中 范围 EKOLAB/LB/PB-212 wydanie 2 z dnia 05.11.2025 r.","methodology_zh":"含量：","test_object_zh":"一般环境"},{"_id":"6a83bcf4af14b9c0e7b213c4","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne","methodology":"Zawartość dwutlenku siarki SO2","parameters":[{"name":"Zakres","range":"(0,050 – 60,0) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość dwutlenku siarki SO2\nZakres (0,050 – 60,0) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Pracownia Laboratorium Analitycznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne Zawartość dwutlenku siarki SO2\nZakres (0,050 – 60,0) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 14791:2017-04 Srodowisko ogolne Zawartosc dwutlenku siarki SO2\nZakres (0,050 – 60,0) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 14791:2017-04","categories":["environment"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide SO2 content","parameters_en":[{"name":"Range","range":"(0,050 – 60,0) mg w próbce"}],"search_en":"General environment Sulfur dioxide SO2 content Ion chromatography with conductometric detection (IC-CD) Range PN-EN 14791:2017-04","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"General environment","parameters_zh":[{"name":"范围","range":"(0,050 – 60,0) mg w próbce"}],"search_zh":"一般环境 离子色谱-电导检测法（IC-CD） 范围 PN-EN 14791:2017-04","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"一般环境"},{"_id":"6a83bcf4af14b9c0e7b213c5","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 - 50 ) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 50) °C\nTemperatura wilgotna naturalna\nZakres (10 - 50 ) °C\nTemperatura poczernionej kuli\nZakres (10 - 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-1 +Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-1 +Ap2:2020-04"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 - 50) °C\nTemperatura wilgotna naturalna\nZakres (10 - 50 ) °C\nTemperatura poczernionej kuli\nZakres (10 - 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-1 +Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 - 50) °C\nTemperatura wilgotna naturalna\nZakres (10 - 50 ) °C\nTemperatura poczernionej kuli\nZakres (10 - 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-1 +Ap2:2020-04","categories":["environment"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 - 50 ) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 50) °C"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-1 +Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 - 50 ) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 50) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-1 +Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83bcf4af14b9c0e7b213c6","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-1 +Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-1 +Ap2:2020-04"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-1 +Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-1 +Ap2:2020-04","categories":["environment"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-1 +Ap2:2020-04","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-1 +Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83bcf4af14b9c0e7b213c7","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 - 80) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,4 - 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (20 - 80) %\nPrędkość powietrza\nZakres (0,4 - 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (20 - 80) %\nPrędkość powietrza\nZakres (0,4 - 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotnosc powietrza\nZakres (20 - 80) %\nPredkosc powietrza\nZakres (0,4 - 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 - 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 - 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 - 80) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,4 - 5,0) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 - 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 - 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 - 80) %"},{"name":"空气流速"},{"name":"范围","range":"(0,4 - 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83bcf4af14b9c0e7b213c8","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutr, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutr, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutr, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutr, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutr index, twc index (calculated)","search_en":"Workplace environment – cold microclimate IREQmin index, IREQneutr index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment – cold microclimate","search_zh":"工作场所环境 — 低温微气候 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83bcf4af14b9c0e7b213c9","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 30) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 - 80) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 30) °C\nWilgotność powietrza\nZakres (20 - 80) %\nPrędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 30) °C\nWilgotność powietrza\nZakres (20 - 80) %\nPrędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 30) °C\nWilgotnosc powietrza\nZakres (20 - 80) %\nPredkosc powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 30) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 - 80) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 30) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 - 80) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83bcf4af14b9c0e7b213ca","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83bcf4af14b9c0e7b213cb","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","norm_bases":["PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r."],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Natężenie oświetlenia\nZakres (0,5 - 5000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r. Srodowisko pracy - oswietlenie elektryczne Natezenie oswietlenia\nZakres (0,5 - 5000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","categories":["environment"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 5000) lx"}],"search_en":"Workplace environment - electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 5000) lx"}],"search_zh":"工作环境 － 电气照明 照度 直接测量法 范围 PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a83bcf4af14b9c0e7b213cc","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","norm_bases":["PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r."],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r. Srodowisko pracy - oswietlenie elektryczne Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","categories":["environment"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","test_object_en":"Workplace environment - electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 电气照明 照度均匀度（计算值） PN-83/E-04040.03 EKOLAB/H/PB–11 wydanie 2 z dnia 10.10.2022 r.","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a83bcf4af14b9c0e7b213cd","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22 - 135) dB"},{"name":"Szczytowy poziom dźwięku C,"},{"name":"Zakres","range":"(42 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22 - 135) dB\nSzczytowy poziom dźwięku C,\nZakres (42 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22 - 135) dB\nSzczytowy poziom dźwięku C,\nZakres (42 - 137) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (22 - 135) dB\nSzczytowy poziom dzwieku C,\nZakres (42 - 137) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(22 - 135) dB"},{"name":"C-weighted peak sound pressure level,"},{"name":"Range","range":"(42 - 137) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level, Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22 - 135) dB"},{"name":"C 计权峰值声级，"},{"name":"范围","range":"(42 - 137) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级， 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83bcf4af14b9c0e7b213ce","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83bcf4af14b9c0e7b213cf","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"związki organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"azbest - włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych - włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nzwiązki organiczne, w tym\nfrakcja wdychalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nazbest - włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych - włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7: 2002+Az1:2004"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nzwiązki organiczne, w tym\nfrakcja wdychalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nazbest - włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych - włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004 Srodowisko pracy Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nzwiazki organiczne, w tym\nfrakcja wdychalna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nazbest - wlokna respirabilne\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych - wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","categories":["materials","environment"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic compounds, including"},{"name":"inhalable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"asbestos - respirable fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres - respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"}],"search_en":"Workplace environment Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction organic compounds, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction asbestos - respirable fibres man-made mineral fibres, excluding refractory ceramic fibres - respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"związki organiczne, w tym"},{"name":"可吸入组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"azbest - włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych - włókna respirabilne"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}],"search_zh":"工作场所环境 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 可吸入组分 金属及其化合物，包括 可吸入组分 呼吸性组分 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213d0","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"związki nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nzwiązki nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7: 2002+Az1:2004"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nzwiązki nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004 Srodowisko pracy Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nzwiazki nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","categories":["environment"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"}],"search_en":"Workplace environment Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method inorganic substances, including inhalable fraction respirable fraction thoracic fraction PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"związki nieorganiczne, w tym"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"}],"search_zh":"工作场所环境 职业接触评估采样，针对： 个体剂量测定法；定点测定法 可吸入组分 呼吸性组分 胸腔组分 PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","test_object_zh":"工作场所环境","technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a83bcf4af14b9c0e7b213d1","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7: 2002+Az1:2004"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004 Srodowisko pracy Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","categories":["environment"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","test_object_en":"Workplace environment","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7: 2002+Az1:2004","test_object_zh":"工作场所环境"},{"_id":"6a83bcf4af14b9c0e7b213d2","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna:"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu, wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Ditlenek tytanu"},{"name":"Zakres","range":"(0,15 - 20,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nDitlenek tytanu\nZakres (0,15 - 20,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nDitlenek tytanu\nZakres (0,15 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna:\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu, wapnia (dolomit)\nWeglik krzemu, niewloknisty\nDitlenek tytanu\nZakres (0,15 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["construction","environment"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica:"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Carbon black"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Magnesium, calcium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Titanium dioxide"},{"name":"Range","range":"(0,15 - 20,4) mg/m3"}],"search_en":"Workplace environment Concentration of harmful dust agents – inhalable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica: Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Talc Coal (hard, brown) Magnesium, calcium carbonate (dolomite) Silicon carbide, non-fibrous Titanium dioxide Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅："},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"镁钙碳酸盐（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"二氧化钛"},{"name":"范围","range":"(0,15 - 20,4) mg/m3"}],"search_zh":"工作场所环境 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅： 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 镁钙碳酸盐（白云石） 碳化硅，非纤维状 二氧化钛 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a83bcf4af14b9c0e7b213d3","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna:"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 - 14,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 - 14,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 - 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna:\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,10 - 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica:"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,10 - 14,6) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica: Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅："},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 - 14,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅： 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a83bcf4af14b9c0e7b213d4","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 - 232) mg/m3"},{"name":"Zakres","range":"(2 - 199) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 - 232) mg/m3\nZakres (2 - 199) ppm\nMetoda elektrochemiczna","reference":"EKOLAB/H/PB-04 wydanie 8 z dnia 01.08.2023 r.","norm_bases":["EKOLAB/H/PB-04 wydanie 8 z dnia 01.08.2023 r."],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 - 232) mg/m3\nZakres (2 - 199) ppm\nMetoda elektrochemiczna EKOLAB/H/PB-04 wydanie 8 z dnia 01.08.2023 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 - 232) mg/m3\nZakres (2 - 199) ppm\nMetoda elektrochemiczna EKOLAB/H/PB-04 wydanie 8 z dnia 01.08.2023 r.","categories":["environment"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 - 232) mg/m3"},{"name":"Range","range":"(2 - 199) ppm"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range Range EKOLAB/H/PB-04 wydanie 8 z dnia 01.08.2023 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(2,3 - 232) mg/m3"},{"name":"范围","range":"(2 - 199) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 EKOLAB/H/PB-04 wydanie 8 z dnia 01.08.2023 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a83bcf4af14b9c0e7b213d5","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie ditlenku węgla","parameters":[{"name":"Zakres","range":"(732 - 73200) mg/m3"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie ditlenku węgla\nZakres (732 - 73200) mg/m3\nMetoda NDIR","reference":"EKOLAB/H/PB-01 wydanie 6 z dnia 01.08.2023 r.","norm_bases":["EKOLAB/H/PB-01 wydanie 6 z dnia 01.08.2023 r."],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie ditlenku węgla\nZakres (732 - 73200) mg/m3\nMetoda NDIR EKOLAB/H/PB-01 wydanie 6 z dnia 01.08.2023 r. Srodowisko pracy - powietrze Stezenie ditlenku wegla\nZakres (732 - 73200) mg/m3\nMetoda NDIR EKOLAB/H/PB-01 wydanie 6 z dnia 01.08.2023 r.","categories":["environment"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"Range","range":"(732 - 73200) mg/m3"}],"search_en":"Workplace environment - air Carbon dioxide concentration NDIR method Range EKOLAB/H/PB-01 wydanie 6 z dnia 01.08.2023 r.","technique_en":"NDIR method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(732 - 73200) mg/m3"}],"search_zh":"工作场所环境 — 空气 二氧化碳浓度 非分散红外法（NDIR） 范围 EKOLAB/H/PB-01 wydanie 6 z dnia 01.08.2023 r.","test_object_zh":"工作场所环境 — 空气","technique_zh":"非分散红外法（NDIR）","methodology_zh":"二氧化碳浓度"},{"_id":"6a83bcf4af14b9c0e7b213d6","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,25 - 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,25 - 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,25 - 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,25 - 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,25 - 100) m/s2"}],"search_en":"Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,25 - 100) m/s2"}],"search_zh":"工作场所环境 − 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 手传振动"},{"_id":"6a83bcf4af14b9c0e7b213d7","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment − hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_en":"Workplace environment − hand-arm vibration","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作场所环境 − 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_zh":"工作场所环境 − 手传振动"},{"_id":"6a83bcf4af14b9c0e7b213d8","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,02 - 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 - 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253:A1:2011","norm_bases":["PN-EN 14253:A1:2011"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,02 - 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253:A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,02 - 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253:A1:2011","categories":["environment"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,02 - 50) m/s2"}],"search_en":"Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253:A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment − whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,02 - 50) m/s2"}],"search_zh":"工作场所环境 − 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253:A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 全身振动"},{"_id":"6a83bcf4af14b9c0e7b213d9","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253:A1:2011","norm_bases":["PN-EN 14253:A1:2011"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253:A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253:A1:2011","categories":["environment"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment − whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253:A1:2011","test_object_en":"Workplace environment − whole-body vibration","search_zh":"工作场所环境 − 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253:A1:2011","test_object_zh":"工作场所环境 − 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a83bcf4af14b9c0e7b213da","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych do 10 do 40 kHz","parameters":[{"name":"Zakres","range":"(54 - 150) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych do 10 do 40 kHz\nZakres (54 - 150) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych do 10 do 40 kHz\nZakres (54 - 150) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy - halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych do 10 do 40 kHz\nZakres (54 - 150) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz","parameters_en":[{"name":"Range","range":"(54 - 150) dB"}],"search_en":"Workplace environment - ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz Direct measurement method Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment - ultrasonic noise","parameters_zh":[{"name":"范围","range":"(54 - 150) dB"}],"search_zh":"工作环境 － 超声噪声 直接测量法 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","test_object_zh":"工作环境 － 超声噪声"},{"_id":"6a83bcf4af14b9c0e7b213db","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz odniesione do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz odniesione do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 do 40 kHz odniesione do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy - halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 do 40 kHz odniesione do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","test_object_en":"Workplace environment - ultrasonic noise","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 － 超声噪声 8 小时日工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","test_object_zh":"工作环境 － 超声噪声"},{"_id":"6a83bcf4af14b9c0e7b213dc","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5 - 35) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 - 60) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 - 35) °C\nPrzepływ powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","norm_bases":["EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r."],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 - 35) °C\nPrzepływ powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r. Srodowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 - 35) °C\nPrzeplyw powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezposrednia EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","categories":["environment"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(5 - 35) °C"},{"name":"Air flow"},{"name":"Range","range":"(10 - 60) dm3/min"}],"search_en":"Workplace environment - energy expenditure Air temperature Direct measurement method Range Air flow Range EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 - 35) °C"},{"name":"空气流量"},{"name":"范围","range":"(10 - 60) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 范围 空气流量 范围 EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a83bcf4af14b9c0e7b213dd","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","norm_bases":["EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r."],"lab_section":"Pracownia Pomiarów Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r. Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen) EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","categories":["environment"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated) EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","test_object_en":"Workplace environment - energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） EKOLAB/H/PB–10 wydanie 2 z dnia 01.07.2019 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a83bcf4af14b9c0e7b213de","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","PN ISO 9613-2:2002"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002 Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (22 - 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","categories":["environment"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(22 - 135) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22 - 135) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83bcf4af14b9c0e7b213df","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda obliczeniowa","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706)","PN ISO 9613-2:2002"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda obliczeniowa Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002 Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)\nMetoda obliczeniowa Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","categories":["environment"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Calculation method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","technique_en":"Calculation method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 计算法 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) | PN ISO 9613-2:2002","technique_zh":"计算法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83bcf4af14b9c0e7b213e0","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych, urządzeń na terenach portów","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych, urządzeń na terenach portów Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych, urzadzen na terenach portow Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (22 - 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wylaczeniem pkt. H","categories":["environment"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(22 - 135) dB"}],"search_en":"General environment - noise from roads, railway lines, tram lines, equipment in port areas A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H","technique_en":"Direct measurement method","test_object_en":"General environment - noise from roads, railway lines, tram lines, equipment in port areas","parameters_zh":[{"name":"范围","range":"(22 - 135) dB"}],"search_zh":"A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级"},{"_id":"6a83bcf4af14b9c0e7b213e1","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych, urządzeń na terenach portów","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych, urządzeń na terenach portów Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych, urzadzen na terenach portow Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wylaczeniem pkt. H","categories":["environment"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from roads, railway lines, tram lines, equipment in port areas A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H","test_object_en":"General environment - noise from roads, railway lines, tram lines, equipment in port areas","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16 czerwca 2011 r. (Dz. U. Nr 140, poz. 824 i Nr 288, poz. 1697) z wyłączeniem pkt. H"},{"_id":"6a83bcf4af14b9c0e7b213e2","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A, LAeq Maksymalny poziom dźwięku A, LAmax","parameters":[{"name":"Zakres","range":"(22 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A, LAeq Maksymalny poziom dźwięku A, LAmax\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-B/87-02156","norm_bases":["PN-B/87-02156"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A, LAeq Maksymalny poziom dźwięku A, LAmax\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia PN-B/87-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A, LAeq Maksymalny poziom dzwieku A, LAmax\nZakres (22 - 135) dB\nMetoda pomiarowa bezposrednia PN-B/87-02156","categories":["environment"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level, LAeq A-weighted maximum sound level, LAmax","parameters_en":[{"name":"Range","range":"(22 - 135) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level, LAeq A-weighted maximum sound level, LAmax Direct measurement method Range PN-B/87-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","parameters_zh":[{"name":"范围","range":"(22 - 135) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 直接测量法 范围 PN-B/87-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83bcf4af14b9c0e7b213e3","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-B/87-02156","norm_bases":["PN-B/87-02156"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-B/87-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-B/87-02156","categories":["environment"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-B/87-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-B/87-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83bcf4af14b9c0e7b213e4","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od wyposażenia technicznego, przenikający do pomieszczeń","methodology":"Równoważny poziomu dźwięku A i C Maksymalny poziom dźwięku A i C","parameters":[{"name":"Zakres","range":"(22 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziomu dźwięku A i C Maksymalny poziom dźwięku A i C\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od wyposażenia technicznego, przenikający do pomieszczeń Równoważny poziomu dźwięku A i C Maksymalny poziom dźwięku A i C\nZakres (22 - 135) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od wyposazenia technicznego, przenikajacy do pomieszczen Rownowazny poziomu dzwieku A i C Maksymalny poziom dzwieku A i C\nZakres (22 - 135) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level","parameters_en":[{"name":"Range","range":"(22 - 135) dB"}],"search_en":"Rooms in residential, collective residence and public buildings – noise from technical services penetrating into rooms A-weighted and C-weighted equivalent sound level A-weighted and C-weighted maximum sound level Direct measurement method Range PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public buildings – noise from technical services penetrating into rooms","parameters_zh":[{"name":"范围","range":"(22 - 135) dB"}],"search_zh":"直接测量法 范围 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","technique_zh":"直接测量法"},{"_id":"6a83bcf4af14b9c0e7b213e5","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od wyposażenia technicznego, przenikający do pomieszczeń","methodology":"Wzorcowy równoważny poziom dźwięku A dla cyklu pracy;, Wzorcowy maksymalny poziom dźwięku A dla cyklu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wzorcowy równoważny poziom dźwięku A dla cyklu pracy;, Wzorcowy maksymalny poziom dźwięku A dla cyklu pracy (z obliczeń)","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od wyposażenia technicznego, przenikający do pomieszczeń Wzorcowy równoważny poziom dźwięku A dla cyklu pracy;, Wzorcowy maksymalny poziom dźwięku A dla cyklu pracy (z obliczeń) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od wyposazenia technicznego, przenikajacy do pomieszczen Wzorcowy rownowazny poziom dzwieku A dla cyklu pracy;, Wzorcowy maksymalny poziom dzwieku A dla cyklu pracy (z obliczen) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment","metrology"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reference equivalent A sound level for the operating cycle;, Reference maximum A sound level for the operating cycle (calculated)","search_en":"Rooms in residential, collective residence and public buildings – noise from technical services penetrating into rooms Reference equivalent A sound level for the operating cycle;, Reference maximum A sound level for the operating cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","test_object_en":"Rooms in residential, collective residence and public buildings – noise from technical services penetrating into rooms"},{"_id":"6a83bcf4af14b9c0e7b213e6","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom ciśnienia akustycznego","parameters":[{"name":"skorygowany charakterystyką"},{"name":"częstotliwościową A"},{"name":"Zakres","range":"(30 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (30 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (30 - 135) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom cisnienia akustycznego\nZakres:\nskorygowany charakterystyka\nczestotliwosciowa A\nZakres (30 - 135) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 z wylaczeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound pressure level","parameters_en":[{"name":"weighted with the characteristic"},{"name":"frequency weighting A"},{"name":"Range","range":"(30 - 135) dB"}],"search_en":"Machinery and equipment – noise Sound pressure level Direct measurement method weighted with the characteristic frequency weighting A Range PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","parameters_zh":[{"name":"按特性计权"},{"name":"A 计权"},{"name":"范围","range":"(30 - 135) dB"}],"search_zh":"机器与设备 – 噪声 声压级 直接测量法 按特性计权 A 计权 范围 PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声压级"},{"_id":"6a83bcf4af14b9c0e7b213e7","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011 z wylaczeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_en":"Machinery and equipment – noise","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a83bcf4af14b9c0e7b213e8","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Powietrze sprężone","methodology":"Pobieranie próbek sprężonego powietrza i azotu do badań zawartości oleju w postaci aerozolu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek sprężonego powietrza i azotu do badań zawartości oleju w postaci aerozolu","reference":"EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","norm_bases":["EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r."],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze sprężone Pobieranie próbek sprężonego powietrza i azotu do badań zawartości oleju w postaci aerozolu EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r. Powietrze sprezone Pobieranie probek sprezonego powietrza i azotu do badan zawartosci oleju w postaci aerozolu EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","categories":["environment","petro"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling of compressed air and nitrogen for testing of oil content in aerosol form","search_en":"Compressed air Sampling of compressed air and nitrogen for testing of oil content in aerosol form EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","test_object_en":"Compressed air","search_zh":"压缩空气 EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","test_object_zh":"压缩空气"},{"_id":"6a83bcf4af14b9c0e7b213e9","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Powietrze sprężone","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","norm_bases":["EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r."],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze sprężone Wskaźnik narażenia (z obliczeń) EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r. Powietrze sprezone Wskaznik narazenia (z obliczen) EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","categories":["environment"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Compressed air Exposure index (calculated) EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","test_object_en":"Compressed air","methodology_zh":"暴露指数（计算得出）","search_zh":"压缩空气 暴露指数（计算得出） EKOLAB/A/PB-01 wydanie 2 z dnia 15.11.2021 r.","test_object_zh":"压缩空气"},{"_id":"6a83bcf4af14b9c0e7b213ea","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Powietrze sprężone","methodology":"Pobieranie próbek sprężonego powietrza i azotu do badań zawartości oleju w postaci aerozolu oraz par","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek sprężonego powietrza i azotu do badań zawartości oleju w postaci aerozolu oraz par","reference":"EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","norm_bases":["EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r."],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze sprężone Pobieranie próbek sprężonego powietrza i azotu do badań zawartości oleju w postaci aerozolu oraz par EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r. Powietrze sprezone Pobieranie probek sprezonego powietrza i azotu do badan zawartosci oleju w postaci aerozolu oraz par EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","categories":["environment","petro"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling of compressed air and nitrogen for testing of oil content in aerosol and vapour form","search_en":"Compressed air Sampling of compressed air and nitrogen for testing of oil content in aerosol and vapour form EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","test_object_en":"Compressed air","search_zh":"压缩空气 EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","test_object_zh":"压缩空气"},{"_id":"6a83bcf4af14b9c0e7b213eb","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Powietrze sprężone","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","norm_bases":["EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r."],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Powietrze sprężone Wskaźnik narażenia (z obliczeń) EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r. Powietrze sprezone Wskaznik narazenia (z obliczen) EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","categories":["environment"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Compressed air Exposure index (calculated) EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","test_object_en":"Compressed air","methodology_zh":"暴露指数（计算得出）","search_zh":"压缩空气 暴露指数（计算得出） EKOLAB/A/PB-03 wydanie 1 z dnia 04.01.2016 r.","test_object_zh":"压缩空气"},{"_id":"6a83bcf4af14b9c0e7b213ec","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne − obiekty budowlane","methodology":"Izolacyjność akustyczna właściwa przybliżona R’ i wzorcowa różnica poziomów DnT między pomieszczeniami, w pasmach 1/3 oktawowych","parameters":[{"name":"Zakres częstotliwości środkowych"},{"name":"pasm","range":"(50 - 5000) Hz"},{"name":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony znormalizowanej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)"}],"technique":"Metoda terenowego pomiaru w warunkach pola rozproszonego","techniques":["Metoda terenowego pomiaru w warunkach pola rozproszonego"],"computed":[],"activity":"Izolacyjność akustyczna właściwa przybliżona R’ i wzorcowa różnica poziomów DnT między pomieszczeniami, w pasmach 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm (50 - 5000) Hz\nWskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony znormalizowanej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)\nMetoda terenowego pomiaru w warunkach pola rozproszonego","reference":"PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem pkt. 7.4 | PN-EN ISO 16283-1:2014-05/ A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","norm_bases":["PN-EN ISO 140-4:2000","PN-EN ISO 16283-1:2014-05 z wyłączeniem pkt. 7.4","PN-EN ISO 16283-1:2014-05/ A1:2018-02","PN-EN ISO 717-1:1999","PN-EN ISO 717-1:2021-06"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − obiekty budowlane Izolacyjność akustyczna właściwa przybliżona R’ i wzorcowa różnica poziomów DnT między pomieszczeniami, w pasmach 1/3 oktawowych\nZakres:\nZakres częstotliwości środkowych\npasm (50 - 5000) Hz\nWskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony znormalizowanej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)\nMetoda terenowego pomiaru w warunkach pola rozproszonego PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem pkt. 7.4 | PN-EN ISO 16283-1:2014-05/ A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06 Srodowisko ogolne − obiekty budowlane Izolacyjnosc akustyczna wlasciwa przyblizona R’ i wzorcowa roznica poziomow DnT miedzy pomieszczeniami, w pasmach 1/3 oktawowych\nZakres:\nZakres czestotliwosci srodkowych\npasm (50 - 5000) Hz\nWskaznik wazony izolacyjnosci akustycznej wlasciwej przyblizonej R’w, i wskaznik wazony znormalizowanej roznicy poziomow DnT,w, oraz widmowe wskazniki adaptacyjne C i Ctr (z obliczen)\nMetoda terenowego pomiaru w warunkach pola rozproszonego PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wylaczeniem pkt. 7.4 | PN-EN ISO 16283-1:2014-05/ A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","categories":["construction","environment","metrology"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Apparent sound reduction index R’ and standardized level difference DnT between rooms, in 1/3 octave bands","parameters_en":[{"name":"Range of centre frequencies"},{"name":"bands","range":"(50 - 5000) Hz"},{"name":"Weighted apparent sound reduction index R’w, and weighted normalized level difference DnT,w, and spectrum adaptation terms C and Ctr (calculated)"}],"search_en":"General environment − building structures Apparent sound reduction index R’ and standardized level difference DnT between rooms, in 1/3 octave bands Field measurement method under diffuse field conditions Range of centre frequencies bands Weighted apparent sound reduction index R’w, and weighted normalized level difference DnT,w, and spectrum adaptation terms C and Ctr (calculated) PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem pkt. 7.4 | PN-EN ISO 16283-1:2014-05/ A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","technique_en":"Field measurement method under diffuse field conditions","test_object_en":"General environment − building structures","search_zh":"扩散场条件下的现场测量法 中心频率范围 频带 PN-EN ISO 140-4:2000 | PN-EN ISO 16283-1:2014-05 z wyłączeniem pkt. 7.4 | PN-EN ISO 16283-1:2014-05/ A1:2018-02 | PN-EN ISO 717-1:1999 | PN-EN ISO 717-1:2021-06","technique_zh":"扩散场条件下的现场测量法","parameters_zh":[{"name":"中心频率范围"},{"name":"频带","range":"(50 - 5000) Hz"},{"name":"Wskaźnik ważony izolacyjności akustycznej właściwej przybliżonej R’w, i wskaźnik ważony znormalizowanej różnicy poziomów DnT,w, oraz widmowe wskaźniki adaptacyjne C i Ctr (z obliczeń)"}]},{"_id":"6a83bcf4af14b9c0e7b213ed","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Środowisko ogólne − obiekty budowlane","methodology":"Poziom uderzeniowy znormalizowany","parameters":[{"name":"L’n, i poziom uderzeniowy wzorcowy"},{"name":"L’nT w pasmach 1/3 oktawowych"},{"name":"Zakres częstotliwości środkowych"},{"name":"pasm","range":"(50 - 5000) Hz"},{"name":"Wskaźnik ważony poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny C1 (z obliczeń)"}],"technique":"Metoda terenowego pomiaru w warunkach pola rozproszonego","techniques":["Metoda terenowego pomiaru w warunkach pola rozproszonego"],"computed":[],"activity":"Poziom uderzeniowy znormalizowany\nZakres:\nL’n, i poziom uderzeniowy wzorcowy\nL’nT w pasmach 1/3 oktawowych\nZakres częstotliwości środkowych\npasm (50 - 5000) Hz\nWskaźnik ważony poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny C1 (z obliczeń)\nMetoda terenowego pomiaru w warunkach pola rozproszonego","reference":"PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem pkt. 7.2.3. oraz pkt. 7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","norm_bases":["PN-EN ISO 140-7:2000","PN-EN ISO 16283-2:2021-02 z wyłączeniem pkt. 7.2.3. oraz pkt. 7.4","PN-EN ISO 717-2:1999","PN-EN ISO 717-2:2021-06"],"lab_section":"Pracownia Akustyki Środowiska i Pomiarów Kwalifikacyjnych Pomieszczeń Czystych i Wentylacji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − obiekty budowlane Poziom uderzeniowy znormalizowany\nZakres:\nL’n, i poziom uderzeniowy wzorcowy\nL’nT w pasmach 1/3 oktawowych\nZakres częstotliwości środkowych\npasm (50 - 5000) Hz\nWskaźnik ważony poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny C1 (z obliczeń)\nMetoda terenowego pomiaru w warunkach pola rozproszonego PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem pkt. 7.2.3. oraz pkt. 7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06 Srodowisko ogolne − obiekty budowlane Poziom uderzeniowy znormalizowany\nZakres:\nL’n, i poziom uderzeniowy wzorcowy\nL’nT w pasmach 1/3 oktawowych\nZakres czestotliwosci srodkowych\npasm (50 - 5000) Hz\nWskaznik wazony poziomu uderzeniowego znormalizowanego L’n,w, i wskaznik wazony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaznik adaptacyjny C1 (z obliczen)\nMetoda terenowego pomiaru w warunkach pola rozproszonego PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wylaczeniem pkt. 7.2.3. oraz pkt. 7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","categories":["environment","construction","metrology"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Normalised impact sound pressure level","parameters_en":[{"name":"L’n, and standardized impact sound level"},{"name":"L’nT in 1/3 octave bands"},{"name":"Range of centre frequencies"},{"name":"bands","range":"(50 - 5000) Hz"},{"name":"Weighted normalized impact sound pressure level L’n,w, and weighted standardized impact sound pressure level L’nT,w and spectrum adaptation term C1 (calculated)"}],"search_en":"General environment − building structures Normalised impact sound pressure level Field measurement method under diffuse field conditions L’n, and standardized impact sound level L’nT in 1/3 octave bands Range of centre frequencies bands Weighted normalized impact sound pressure level L’n,w, and weighted standardized impact sound pressure level L’nT,w and spectrum adaptation term C1 (calculated) PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem pkt. 7.2.3. oraz pkt. 7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","technique_en":"Field measurement method under diffuse field conditions","test_object_en":"General environment − building structures","search_zh":"扩散场条件下的现场测量法 中心频率范围 频带 PN-EN ISO 140-7:2000 | PN-EN ISO 16283-2:2021-02 z wyłączeniem pkt. 7.2.3. oraz pkt. 7.4 | PN-EN ISO 717-2:1999 | PN-EN ISO 717-2:2021-06","technique_zh":"扩散场条件下的现场测量法","parameters_zh":[{"name":"L’n, i poziom uderzeniowy wzorcowy"},{"name":"L’nT w pasmach 1/3 oktawowych"},{"name":"中心频率范围"},{"name":"频带","range":"(50 - 5000) Hz"},{"name":"Wskaźnik ważony poziomu uderzeniowego znormalizowanego L’n,w, i wskaźnik ważony poziomu uderzeniowego wzorcowego L’nT,w oraz widmowy wskaźnik adaptacyjny C1 (z obliczeń)"}]},{"_id":"6a83bcf4af14b9c0e7b213ee","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczeń stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczeń stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczeń stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do oznaczen stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for determinations of dust concentration","search_en":"Waste gases Dust sampling for determinations of dust concentration PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b213ef","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(1,0 - 1000) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (1,0 - 1000) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (1,0 - 1000) mg/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (1,0 - 1000) mg/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(1,0 - 1000) mg/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(1,0 - 1000) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b213f0","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b213f1","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczeń stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczeń stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczeń stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek pylu do oznaczen stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for determinations of dust concentration","search_en":"Waste gases Dust sampling for determinations of dust concentration PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 PN-EN 13284-1:2018-02","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b213f2","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(1,0 - 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (1,0 - 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (1,0 - 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (1,0 - 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(1,0 - 50) mg/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(1,0 - 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b213f3","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b213f4","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a83bcf4af14b9c0e7b213f5","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Prędkość gazów","parameters":[{"name":"Zakres","range":"(1,0 - 15) m/s"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"computed":[],"activity":"Prędkość gazów\nZakres (1,0 - 15) m/s\nMetoda termoanemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Prędkość gazów\nZakres (1,0 - 15) m/s\nMetoda termoanemometryczna PN-Z-04030-7:1994 Gazy odlotowe Predkosc gazow\nZakres (1,0 - 15) m/s\nMetoda termoanemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas velocity","parameters_en":[{"name":"Range","range":"(1,0 - 15) m/s"}],"search_en":"Waste gases Gas velocity Thermoanemometric method Range PN-Z-04030-7:1994","technique_en":"Thermoanemometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 15) m/s"}],"search_zh":"废气 热线风速仪法 范围 PN-Z-04030-7:1994","test_object_zh":"废气","technique_zh":"热线风速仪法"},{"_id":"6a83bcf4af14b9c0e7b213f6","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen chloride concentration","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 氯化氢浓度测定采样 PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a83bcf4af14b9c0e7b213f7","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HCl (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HCl emission (calculated)","search_en":"Waste gases HCl emission (calculated) PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 HCl 排放（由计算得出） PN-EN 1911:2011","test_object_zh":"废气","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a83bcf4af14b9c0e7b213f8","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen fluoride concentration","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 氟化氢浓度测定采样 ISO 15713:2006","test_object_zh":"废气","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a83bcf4af14b9c0e7b213f9","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HF emission (calculated)","search_en":"Waste gases HF emission (calculated) ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 HF 排放量（计算值） ISO 15713:2006","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b213fa","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V PN-EN 14385:2005","categories":["materials"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V","search_en":"Waste gases Sampling for determination of metal concentrations As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V PN-EN 14385:2005","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b213fb","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V (z obliczeń)","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V (z obliczeń) PN-EN 14385:2005 Gazy odlotowe Emisja metali As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V (z obliczen) PN-EN 14385:2005","categories":["materials","environment"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of metals As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V (calculated)","search_en":"Waste gases Emission of metals As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI, V (calculated) PN-EN 14385:2005","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b213fc","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of total mercury concentration","search_en":"Waste gases Sampling for determination of total mercury concentration PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞浓度测定采样 PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a83bcf4af14b9c0e7b213fd","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mercury emission (calculated)","search_en":"Waste gases Total mercury emission (calculated) PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞排放量（计算值） PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b213fe","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku węgla, dwutlenku siarki, dwutlenku węgla","parameters":[{"name":"CO","range":"(1,3 - 3000) mg/m3"},{"name":"SO2","range":"(3,0 - 1000) mg/m3"},{"name":"CO2","range":"(1,0 - 20,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenku węgla, dwutlenku siarki, dwutlenku węgla\nZakres:\nCO (1,3 - 3000) mg/m3\nSO2 (3,0 - 1000) mg/m3\nCO2 (1,0 - 20,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku węgla, dwutlenku siarki, dwutlenku węgla\nZakres:\nCO (1,3 - 3000) mg/m3\nSO2 (3,0 - 1000) mg/m3\nCO2 (1,0 - 20,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenku wegla, dwutlenku siarki, dwutlenku wegla\nZakres:\nCO (1,3 - 3000) mg/m3\nSO2 (3,0 - 1000) mg/m3\nCO2 (1,0 - 20,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of carbon monoxide, sulphur dioxide, carbon dioxide","parameters_en":[{"name":"CO","range":"(1,3 - 3000) mg/m3"},{"name":"SO2","range":"(3,0 - 1000) mg/m3"},{"name":"CO2","range":"(1,0 - 20,0) %"}],"search_en":"Waste gases Concentration of carbon monoxide, sulphur dioxide, carbon dioxide Non-dispersive infrared spectrometry (NDIR) CO SO2 CO2 PN-ISO 10396:2001","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","search_zh":"废气 非分散红外光谱法（NDIR） CO SO2 CO2 PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"CO","range":"(1,3 - 3000) mg/m3"},{"name":"SO2","range":"(3,0 - 1000) mg/m3"},{"name":"CO2","range":"(1,0 - 20,0) %"}],"technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a83bcf4af14b9c0e7b213ff","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(1,0 - 21,0) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu\nZakres (1,0 - 21,0) %\nMetoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(1,0 - 21,0) %"}],"search_en":"Waste gases Oxygen concentration Electrochemical method Range PN-ISO 10396:2001","technique_en":"Electrochemical method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 21,0) %"}],"search_zh":"废气 氧浓度 电化学法 范围 PN-ISO 10396:2001","technique_zh":"电化学法","test_object_zh":"废气","methodology_zh":"氧浓度"},{"_id":"6a83bcf4af14b9c0e7b21400","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(1,0 - 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(1,0 - 21,0) %"}],"search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-ISO 10396:2001","technique_en":"Paramagnetic method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 21,0) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a83bcf4af14b9c0e7b21401","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, tlenków azotu","parameters":[{"name":"NO","range":"(1,5 - 300) mg/mɜ"},{"name":"NOx","range":"(2,0 - 400) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (1,5 - 300) mg/mɜ\nNOx (2,0 - 400) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (1,5 - 300) mg/mɜ\nNOx (2,0 - 400) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (1,5 - 300) mg/mɜ\nNOx (2,0 - 400) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001","categories":["other"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters_en":[{"name":"NO","range":"(1,5 - 300) mg/mɜ"},{"name":"NOx","range":"(2,0 - 400) mg/m3"}],"search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method NO NOx PN-ISO 10396:2001","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","search_zh":"废气 一氧化氮、氮氧化物浓度 化学发光法 NO NOx PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(1,5 - 300) mg/mɜ"},{"name":"NOx","range":"(2,0 - 400) mg/m3"}],"technique_zh":"化学发光法","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a83bcf4af14b9c0e7b21402","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO, CO2, NO, SO2, NOx (NO, NOx w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO, CO2, NO, SO2, NOx (NO, NOx w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja CO, CO2, NO, SO2, NOx (NO, NOx w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja CO, CO2, NO, SO2, NOx (NO, NOx w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21403","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(2,0 - 800) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2,0 - 800) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2,0 - 800) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (2,0 - 800) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(2,0 - 800) mg/m3"}],"search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,0 - 800) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a83bcf4af14b9c0e7b21404","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05","test_object_en":"Waste gases","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b21405","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczeń stężeń związków organicznych","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego i roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego i roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczeń stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego i roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczeń stężeń związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego i roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczen stezen zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego i roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determinations of the concentrations of organic compounds","search_en":"Waste gases Sampling for determinations of the concentrations of organic compounds Aspiration method using activated carbon and absorbing solutions PN-Z-04008-4:1999","technique_en":"Aspiration method using activated carbon and absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04008-4:1999","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21406","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zwiazkow organicznych (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic compounds (calculated)","search_en":"Waste gases Emission of organic compounds (calculated) PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物排放量（计算值） PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b21407","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania indywidualnych gazowych związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania indywidualnych gazowych związków organicznych","reference":"PN EN 13649:2005","norm_bases":["PN EN 13649:2005"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania indywidualnych gazowych związków organicznych PN EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania indywidualnych gazowych zwiazkow organicznych PN EN 13649:2005","categories":["other"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of individual gaseous organic compounds","search_en":"Waste gases Sampling for determination of individual gaseous organic compounds PN EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 PN EN 13649:2005","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21408","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN EN 13649:2005","norm_bases":["PN EN 13649:2005"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego; Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN EN 13649:2005","categories":["environment"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） PN EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b21409","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy składowiskowe, Powietrze glebowe, Biogaz","methodology":"Prędkość przepływu","parameters":[{"name":"Zakres","range":"(0,5 - 20,0) m/s"}],"technique":"Metoda termoanemometryczna","techniques":["Metoda termoanemometryczna"],"computed":[],"activity":"Prędkość przepływu\nZakres (0,5 - 20,0) m/s\nMetoda termoanemometryczna","reference":"EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Powietrze glebowe, Biogaz Prędkość przepływu\nZakres (0,5 - 20,0) m/s\nMetoda termoanemometryczna EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r. Gazy skladowiskowe, Powietrze glebowe, Biogaz Predkosc przeplywu\nZakres (0,5 - 20,0) m/s\nMetoda termoanemometryczna EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","categories":["environment"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Flow velocity","parameters_en":[{"name":"Range","range":"(0,5 - 20,0) m/s"}],"search_en":"Landfill gas, Soil air, Biogas Flow velocity Thermoanemometric method Range EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","technique_en":"Thermoanemometric method","test_object_en":"Landfill gas, Soil air, Biogas","parameters_zh":[{"name":"范围","range":"(0,5 - 20,0) m/s"}],"search_zh":"填埋气、土壤气、沼气 流速 热线风速仪法 范围 EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","methodology_zh":"流速","technique_zh":"热线风速仪法","test_object_zh":"填埋气、土壤气、沼气"},{"_id":"6a83bcf4af14b9c0e7b2140a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy składowiskowe, Powietrze glebowe, Biogaz","methodology":"Prędkość gazów","parameters":[{"name":"Zakres","range":"(0,5 - 15,0) m/s"}],"technique":"Metoda anemometryczna","techniques":["Metoda anemometryczna"],"computed":[],"activity":"Prędkość gazów\nZakres (0,5 - 15,0) m/s\nMetoda anemometryczna","reference":"EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Powietrze glebowe, Biogaz Prędkość gazów\nZakres (0,5 - 15,0) m/s\nMetoda anemometryczna EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r. Gazy skladowiskowe, Powietrze glebowe, Biogaz Predkosc gazow\nZakres (0,5 - 15,0) m/s\nMetoda anemometryczna EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","categories":["environment"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas velocity","parameters_en":[{"name":"Range","range":"(0,5 - 15,0) m/s"}],"search_en":"Landfill gas, Soil air, Biogas Gas velocity Anemometric method Range EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","technique_en":"Anemometric method","test_object_en":"Landfill gas, Soil air, Biogas","parameters_zh":[{"name":"范围","range":"(0,5 - 15,0) m/s"}],"search_zh":"填埋气、土壤气、沼气 风速仪法 范围 EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","technique_zh":"风速仪法","test_object_zh":"填埋气、土壤气、沼气"},{"_id":"6a83bcf4af14b9c0e7b2140b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy składowiskowe, Powietrze glebowe, Biogaz","methodology":"Stężenie tlenu, dwutlenku węgla, metanu","parameters":[{"name":"O2","range":"(0,2 - 21,0) %"},{"name":"CO2","range":"(0,2 - 40,0)%"},{"name":"CH4","range":"(0,2 - 70,0)%"}],"technique":"Metoda elektrochemiczna; Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda elektrochemiczna","Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie tlenu, dwutlenku węgla, metanu\nZakres:\nO2 (0,2 - 21,0) %\nCO2 (0,2 - 40,0)%\nCH4 (0,2 - 70,0)%\nMetoda elektrochemiczna; Metoda spektrometrii w podczerwieni (IR)","reference":"EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Powietrze glebowe, Biogaz Stężenie tlenu, dwutlenku węgla, metanu\nZakres:\nO2 (0,2 - 21,0) %\nCO2 (0,2 - 40,0)%\nCH4 (0,2 - 70,0)%\nMetoda elektrochemiczna; Metoda spektrometrii w podczerwieni (IR) EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r. Gazy skladowiskowe, Powietrze glebowe, Biogaz Stezenie tlenu, dwutlenku wegla, metanu\nZakres:\nO2 (0,2 - 21,0) %\nCO2 (0,2 - 40,0)%\nCH4 (0,2 - 70,0)%\nMetoda elektrochemiczna; Metoda spektrometrii w podczerwieni (IR) EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","categories":["environment"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of oxygen, carbon dioxide, methane","parameters_en":[{"name":"O2","range":"(0,2 - 21,0) %"},{"name":"CO2","range":"(0,2 - 40,0)%"},{"name":"CH4","range":"(0,2 - 70,0)%"}],"search_en":"Landfill gas, Soil air, Biogas Concentration of oxygen, carbon dioxide, methane Electrochemical method; Infrared spectrometry (IR) O2 CO2 CH4 EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","technique_en":"Electrochemical method; Infrared spectrometry (IR)","test_object_en":"Landfill gas, Soil air, Biogas","parameters_zh":[{"name":"O2","range":"(0,2 - 21,0) %"},{"name":"CO2","range":"(0,2 - 40,0)%"},{"name":"CH4","range":"(0,2 - 70,0)%"}],"search_zh":"填埋气、土壤气、沼气 O2 CO2 EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","test_object_zh":"填埋气、土壤气、沼气"},{"_id":"6a83bcf4af14b9c0e7b2140c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy składowiskowe, Powietrze glebowe, Biogaz","methodology":"Emisja O2, CO2, CH4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja O2, CO2, CH4 (z obliczeń)","reference":"EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Powietrze glebowe, Biogaz Emisja O2, CO2, CH4 (z obliczeń) EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r. Gazy skladowiskowe, Powietrze glebowe, Biogaz Emisja O2, CO2, CH4 (z obliczen) EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","categories":["environment"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of O2, CO2, CH4 (calculated)","search_en":"Landfill gas, Soil air, Biogas Emission of O2, CO2, CH4 (calculated) EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","test_object_en":"Landfill gas, Soil air, Biogas","search_zh":"填埋气、土壤气、沼气 EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","test_object_zh":"填埋气、土壤气、沼气"},{"_id":"6a83bcf4af14b9c0e7b2140d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy składowiskowe, Powietrze glebowe, Biogaz","methodology":"Pobieranie próbek gazów do oznaczenia stężeń O2,CO2, CH4, H2S, węglowodorów, C2-C5","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem worków tedlarowych","techniques":["Metoda aspiracyjna z zastosowaniem worków tedlarowych"],"computed":[],"activity":"Pobieranie próbek gazów do oznaczenia stężeń O2,CO2, CH4, H2S, węglowodorów, C2-C5\nMetoda aspiracyjna z zastosowaniem worków tedlarowych","reference":"EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe, Powietrze glebowe, Biogaz Pobieranie próbek gazów do oznaczenia stężeń O2,CO2, CH4, H2S, węglowodorów, C2-C5\nMetoda aspiracyjna z zastosowaniem worków tedlarowych EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r. Gazy skladowiskowe, Powietrze glebowe, Biogaz Pobieranie probek gazow do oznaczenia stezen O2,CO2, CH4, H2S, weglowodorow, C2-C5\nMetoda aspiracyjna z zastosowaniem workow tedlarowych EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","categories":["environment"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas sampling for determination of the concentrations of O2,CO2, CH4, H2S, hydrocarbons, C2-C5","search_en":"Landfill gas, Soil air, Biogas Gas sampling for determination of the concentrations of O2,CO2, CH4, H2S, hydrocarbons, C2-C5 Aspiration method using Tedlar bags EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","technique_en":"Aspiration method using Tedlar bags","test_object_en":"Landfill gas, Soil air, Biogas","search_zh":"填埋气、土壤气、沼气 EKOLAB/E/PB-04 wydanie 3 z dnia 03.11.2023 r.","test_object_zh":"填埋气、土壤气、沼气"},{"_id":"6a83bcf4af14b9c0e7b2140e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek gazów do oznaczenia stężeń: H2S, merkaptanów, CH4, CS2, węglowodorów C2-C5","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem worków tedlarowych","techniques":["Metoda aspiracyjna z zastosowaniem worków tedlarowych"],"computed":[],"activity":"Pobieranie próbek gazów do oznaczenia stężeń: H2S, merkaptanów, CH4, CS2, węglowodorów C2-C5\nMetoda aspiracyjna z zastosowaniem worków tedlarowych","reference":"EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek gazów do oznaczenia stężeń: H2S, merkaptanów, CH4, CS2, węglowodorów C2-C5\nMetoda aspiracyjna z zastosowaniem worków tedlarowych EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r. Gazy odlotowe Pobieranie probek gazow do oznaczenia stezen: H2S, merkaptanow, CH4, CS2, weglowodorow C2-C5\nMetoda aspiracyjna z zastosowaniem workow tedlarowych EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","categories":["other"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas sampling for determination of the concentrations of: H2S, mercaptans, CH4, CS2, hydrocarbons C2-C5","search_en":"Waste gases Gas sampling for determination of the concentrations of: H2S, mercaptans, CH4, CS2, hydrocarbons C2-C5 Aspiration method using Tedlar bags EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","technique_en":"Aspiration method using Tedlar bags","test_object_en":"Waste gases","search_zh":"废气 EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b2140f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczeń stężenia pyłu PM 2,5 i PM 10","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczeń stężenia pyłu PM 2,5 i PM 10","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczeń stężenia pyłu PM 2,5 i PM 10 PN-EN ISO 23210:2010 Gazy odlotowe Pobieranie probek pylu do oznaczen stezenia pylu PM 2,5 i PM 10 PN-EN ISO 23210:2010","categories":["other"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for determinations of the concentration of PM 2,5 and PM 10 dust","search_en":"Waste gases Dust sampling for determinations of the concentration of PM 2,5 and PM 10 dust PN-EN ISO 23210:2010","test_object_en":"Waste gases","search_zh":"废气 PN-EN ISO 23210:2010","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21410","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu PM 2,5 i PM 10","parameters":[{"name":"Zakres","range":"(1,0 - 40) mg/m3"}],"technique":"Metoda impakcyjna","techniques":["Metoda impakcyjna"],"computed":[],"activity":"Stężenie pyłu PM 2,5 i PM 10\nZakres (1,0 - 40) mg/m3\nMetoda impakcyjna","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu PM 2,5 i PM 10\nZakres (1,0 - 40) mg/m3\nMetoda impakcyjna PN-EN ISO 23210:2010 Gazy odlotowe Stezenie pylu PM 2,5 i PM 10\nZakres (1,0 - 40) mg/m3\nMetoda impakcyjna PN-EN ISO 23210:2010","categories":["other"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PM 2,5 and PM 10 dust concentration","parameters_en":[{"name":"Range","range":"(1,0 - 40) mg/m3"}],"search_en":"Waste gases PM 2,5 and PM 10 dust concentration Impaction method Range PN-EN ISO 23210:2010","technique_en":"Impaction method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 40) mg/m3"}],"search_zh":"废气 PM 2,5 与 PM 10 粉尘浓度 撞击法 范围 PN-EN ISO 23210:2010","test_object_zh":"废气","technique_zh":"撞击法","methodology_zh":"PM 2,5 与 PM 10 粉尘浓度"},{"_id":"6a83bcf4af14b9c0e7b21411","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu PM 2,5 i PM 10 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu PM 2,5 i PM 10 (z obliczeń)","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja pyłu PM 2,5 i PM 10 (z obliczeń) PN-EN ISO 23210:2010 Gazy odlotowe Emisja pylu PM 2,5 i PM 10 (z obliczen) PN-EN ISO 23210:2010","categories":["environment"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PM 2,5 and PM 10 dust emission (calculated)","search_en":"Waste gases PM 2,5 and PM 10 dust emission (calculated) PN-EN ISO 23210:2010","test_object_en":"Waste gases","search_zh":"废气 PM 2,5 与 PM 10 粉尘排放（由计算得出） PN-EN ISO 23210:2010","test_object_zh":"废气","methodology_zh":"PM 2,5 与 PM 10 粉尘排放（由计算得出）"},{"_id":"6a83bcf4af14b9c0e7b21412","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczeń stężenia metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl,","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczeń stężenia metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl,","reference":"PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","norm_bases":["PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczeń stężenia metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r. Gazy odlotowe Pobieranie probek pylu do oznaczen stezenia metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","categories":["materials"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for determinations of metal concentrations in dust Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl,","search_en":"Waste gases Dust sampling for determinations of metal concentrations in dust Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21413","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, (z obliczeń)","reference":"PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","norm_bases":["PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, (z obliczeń) PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r. Gazy odlotowe Emisja metali w pyle Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, (z obliczen) PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","categories":["materials","environment"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of metals in dust Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, (calculated)","search_en":"Waste gases Emission of metals in dust Ag, As, B, Be, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Sn, Ti, V, Zn, Tl, (calculated) PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994 EKOLAB/E/PB-03 wydanie 7 z dnia 12.07.2021 r.","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21414","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężeń, NH3, HF, HCN, NaOH, O3, F2, Cl2","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężeń, NH3, HF, HCN, NaOH, O3, F2, Cl2\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń, NH3, HF, HCN, NaOH, O3, F2, Cl2\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r. Gazy odlotowe Pobieranie probek do oznaczania stezen, NH3, HF, HCN, NaOH, O3, F2, Cl2\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","categories":["other"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentrations, NH3, HF, HCN, NaOH, O3, F2, Cl2","search_en":"Waste gases Sampling for determination of the concentrations, NH3, HF, HCN, NaOH, O3, F2, Cl2 Aspiration method using absorbing solutions EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","technique_en":"Aspiration method using absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 采用吸收液的抽气法 EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","test_object_zh":"废气","technique_zh":"采用吸收液的抽气法"},{"_id":"6a83bcf4af14b9c0e7b21415","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężeń, H2SO4","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem filtrów membranowych","techniques":["Metoda aspiracyjna z zastosowaniem filtrów membranowych"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężeń, H2SO4\nMetoda aspiracyjna z zastosowaniem filtrów membranowych","reference":"EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń, H2SO4\nMetoda aspiracyjna z zastosowaniem filtrów membranowych EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r. Gazy odlotowe Pobieranie probek do oznaczania stezen, H2SO4\nMetoda aspiracyjna z zastosowaniem filtrow membranowych EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","categories":["other"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentrations, H2SO4","search_en":"Waste gases Sampling for determination of the concentrations, H2SO4 Aspiration method using membrane filters EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","technique_en":"Aspiration method using membrane filters","test_object_en":"Waste gases","search_zh":"废气 EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21416","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NH3, HF, HCN, NaOH, O3, F2, Cl2, H2SO4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NH3, HF, HCN, NaOH, O3, F2, Cl2, H2SO4 (z obliczeń)","reference":"EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","norm_bases":["EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r."],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja NH3, HF, HCN, NaOH, O3, F2, Cl2, H2SO4 (z obliczeń) EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r. Gazy odlotowe Emisja NH3, HF, HCN, NaOH, O3, F2, Cl2, H2SO4 (z obliczen) EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","categories":["environment"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of NH3, HF, HCN, NaOH, O3, F2, Cl2, H2SO4 (calculated)","search_en":"Waste gases Emission of NH3, HF, HCN, NaOH, O3, F2, Cl2, H2SO4 (calculated) EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","test_object_en":"Waste gases","search_zh":"废气 EKOLAB/E/PB-5 wydanie 6 z dnia 03.11.2023 r.","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b21417","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of ammonia concentration","search_en":"Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨浓度测定采样 PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨浓度测定采样"},{"_id":"6a83bcf4af14b9c0e7b21418","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NH3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NH3 (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja NH3 (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja NH3 (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NH3 emission (calculated)","search_en":"Waste gases NH3 emission (calculated) PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 NH3 排放（由计算得出） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"NH3 排放（由计算得出）"},{"_id":"6a83bcf4af14b9c0e7b21419","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(1,0 - 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(1,0 - 21,0) %"}],"search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-EN 14789:2017-04","technique_en":"Paramagnetic method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 21,0) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a83bcf4af14b9c0e7b2141a","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia SO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-04","categories":["other"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of SO2 concentration","search_en":"Waste gases Sampling for determination of SO2 concentration PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 用于测定 SO2 浓度的采样 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a83bcf4af14b9c0e7b2141b","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 emission (calculated)","search_en":"Waste gases SO2 emission (calculated) PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 SO2 排放量（计算值） PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b2141c","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, tlenków azotu","parameters":[{"name":"NO","range":"(1,5 - 300) mg/mɜ"},{"name":"NOx","range":"(2,3 - 400) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (1,5 - 300) mg/mɜ\nNOx (2,3 - 400) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (1,5 - 300) mg/mɜ\nNOx (2,3 - 400) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (1,5 - 300) mg/mɜ\nNOx (2,3 - 400) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04","categories":["other"],"row_index":290,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters_en":[{"name":"NO","range":"(1,5 - 300) mg/mɜ"},{"name":"NOx","range":"(2,3 - 400) mg/m3"}],"search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method NO NOx PN-EN 14792:2017-04","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","search_zh":"废气 一氧化氮、氮氧化物浓度 化学发光法 NO NOx PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(1,5 - 300) mg/mɜ"},{"name":"NOx","range":"(2,3 - 400) mg/m3"}],"technique_zh":"化学发光法","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a83bcf4af14b9c0e7b2141d","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO, NOx w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO, NOx w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO, NOx w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NO, NOx w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":291,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Waste gases PN-EN 14792:2017-04","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a83bcf4af14b9c0e7b2141e","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku węgla CO","parameters":[{"name":"Zakres","range":"(1,3 - 3000) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenku węgla CO\nZakres (1,3 - 3000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 15058:2017-04","norm_bases":["PN-EN ISO 15058:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku węgla CO\nZakres (1,3 - 3000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla CO\nZakres (1,3 - 3000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 15058:2017-04","categories":["other"],"row_index":292,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,3 - 3000) mg/m3"}],"search_en":"Waste gases Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 15058:2017-04","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,3 - 3000) mg/m3"}],"search_zh":"废气 非分散红外光谱法（NDIR） 范围 PN-EN ISO 15058:2017-04","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a83bcf4af14b9c0e7b2141f","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN ISO 15058:2017-04","norm_bases":["PN-EN ISO 15058:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN ISO 15058:2017-04 Gazy odlotowe Emisja CO (z obliczen) PN-EN ISO 15058:2017-04","categories":["environment"],"row_index":293,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO emission (calculated)","search_en":"Waste gases CO emission (calculated) PN-EN ISO 15058:2017-04","test_object_en":"Waste gases","search_zh":"废气 CO 排放量（计算值） PN-EN ISO 15058:2017-04","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a83bcf4af14b9c0e7b21420","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku węgla CO2","parameters":[{"name":"Zakres","range":"(1,0 - 20,0) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie dwutlenku węgla CO2\nZakres (1,0 - 20,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla CO2\nZakres (1,0 - 20,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Gazy odlotowe Stezenie dwutlenku wegla CO2\nZakres (1,0 - 20,0) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":294,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,0 - 20,0) %"}],"search_en":"Waste gases Non-dispersive infrared spectrometry (NDIR) Range ISO 12039:2019","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 20,0) %"}],"search_zh":"废气 非分散红外光谱法（NDIR） 范围 ISO 12039:2019","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a83bcf4af14b9c0e7b21421","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO2 (z obliczeń)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja CO2 (z obliczeń) ISO 12039:2019 Gazy odlotowe Emisja CO2 (z obliczen) ISO 12039:2019","categories":["environment"],"row_index":295,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 emission (calculated)","search_en":"Waste gases CO2 emission (calculated) ISO 12039:2019","test_object_en":"Waste gases","search_zh":"废气 CO2 排放（由计算得出） ISO 12039:2019","test_object_zh":"废气","methodology_zh":"CO2 排放（由计算得出）"},{"_id":"6a83bcf4af14b9c0e7b21422","lab_id":"69ad52a3de79e566650fb460","country":"PL","accr_number":"AB 869","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(29 - 250) g/m3"},{"name":"Zakres","range":"(4,0 - 40,0) %"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (29 - 250) g/m3\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Pracownia Pomiarów Emisji Zanieczyszczeń","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres:\nZakres (29 - 250) g/m3\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres:\nZakres (29 - 250) g/m3\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":296,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(29 - 250) g/m3"},{"name":"Range","range":"(4,0 - 40,0) %"}],"search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method Range Range PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(29 - 250) g/m3"},{"name":"范围","range":"(4,0 - 40,0) %"}],"search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 范围 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"}],"has_pdf":true}