{"lab":{"_id":"69ad52a3de79e566650fb45c","accr_number":"AB 865","country":"PL","accr_body":"PCA","address":"Izabela Grabowska, ul. Rakowiecka 36 lok. F20, 02-532 Warszawa","categories":["environment","construction"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":37,"name":"ZAKŁAD BADAŃ ŚRODOWISKA PRACY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_865.pdf"],"scope_summary":"","search_text":"zakład badań środowiska pracy izabela grabowska, ul. rakowiecka 36 lok. f20, 02-532 warszawa environment other materials construction electronics pharma metrology","status":"active","updated_at":"2026-03-08T14:51:45.084Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:45.084Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"low","email_mx":true,"email_source":"http://www.zbsp.com.pl/kontakt.html","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling - working environment (harmful factors – air),"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie, mikroklimat, wydatek energetyczny)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate, energy expenditure)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise),"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"23","date":"29.10.2025"},"parse_date":"2026-07-20T07:09:52.803Z","parse_source":"script-pdfplumber","map_coord":[52.207446,21.000691],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":37,"construction":2,"materials":1},"category_scores":{"environment":34.23,"construction":0.1,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a5dc9c0f1c10c8ce825f311","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe, frakcja wdychalna frakcja respirabilna"}],"parameters_en":[{"name":"dust agents, inhalable fraction respirable fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe, frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004","PN-88/Z-04202/02 pkt 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe, frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nczynniki pylowe, frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents, inhalable fraction respirable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法 PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f312","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"substancje organiczne, w tym frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna"},{"name":"metale i ich związki, w tym frakcja wdychalna frakcja respirabilna"},{"name":"azbest"},{"name":"włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"włókna respirabilne"}],"parameters_en":[{"name":"organic substances, including inhalable fraction"},{"name":"inorganic substances, including inhalable fraction respirable fraction thoracic fraction"},{"name":"metals and their compounds, including inhalable fraction respirable fraction"},{"name":"asbestos"},{"name":"respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres"},{"name":"respirable fibres"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"technique_en":"Personal dosimetry method; Stationary method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nazbest\nwłókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004","PN-88/Z-04202/02 pkt 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nazbest\nwłókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nmetale i ich zwiazki, w tym frakcja wdychalna frakcja respirabilna\nazbest\nwlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych\nwlokna respirabilne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","categories":["materials","environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction asbestos respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 有机物质，其中包括可吸入性粉尘 无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘 金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘 石棉 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 人造矿物纤维，耐火陶瓷纤维除外 呼吸性纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","test_object_zh":"工作环境 − 空气","parameters_zh":[{"name":"有机物质，其中包括可吸入性粉尘"},{"name":"无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘"},{"name":"金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘"},{"name":"石棉"},{"name":"呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"呼吸性纤维"}],"technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a5dc9c0f1c10c8ce825f313","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004","PN-88/Z-04202/02 pkt 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 | PN-88/Z-04202/02 pkt 7","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f314","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:","methodology_en":"Concentration of harmful dust agents – inhalable fraction:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit: a) grafit naturalny b) grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu, wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,10 - 21,17) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Graphite: a) natural graphite b) synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica: a) diatomaceous earth (diatomite) uncalcined b) diatomaceous earth (diatomite) calcined c) synthetic amorphous silica (precipitated and gel) d) fused silica (quartz glass)"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Carbon black"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Magnesium, calcium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,10 - 21,17) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit: a) grafit naturalny b) grafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,10 - 21,17) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit: a) grafit naturalny b) grafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,10 - 21,17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit: a) grafit naturalny b) grafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (stracona i zel) d) krzemionka stopiona (szklo kwarcowe)\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu, wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,10 - 21,17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents – inhalable fraction: Gravimetric method Apatites and phosphorites Portland cement Titanium dioxide Graphite: a) natural graphite b) synthetic graphite Kaolin Amorphous and synthetic silica: a) diatomaceous earth (diatomite) uncalcined b) diatomaceous earth (diatomite) calcined c) synthetic amorphous silica (precipitated and gel) d) fused silica (quartz glass) Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Talc Coal (hard, brown) Magnesium, calcium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"Grafit: a) grafit naturalny b) grafit syntetyczny"},{"name":"高岭土"},{"name":"Krzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"镁钙碳酸盐（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,10 - 21,17) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 高岭土 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 镁钙碳酸盐（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a5dc9c0f1c10c8ce825f315","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:","methodology_en":"Concentration of harmful dust agents – respirable fraction:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit a) grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,08 - 7,31) mg/m3"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Graphite a) natural graphite"},{"name":"Amorphous and synthetic silica: a) diatomaceous earth (diatomite) uncalcined b) diatomaceous earth (diatomite) calcined c) synthetic amorphous silica (precipitated and gel) d) fused silica (quartz glass)"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,08 - 7,31) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit a) grafit naturalny\nKrzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,08 - 7,31) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit a) grafit naturalny\nKrzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,08 - 7,31) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit a) grafit naturalny\nKrzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (stracona i zel) d) krzemionka stopiona (szklo kwarcowe)\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,08 - 7,31) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents – respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Graphite a) natural graphite Amorphous and synthetic silica: a) diatomaceous earth (diatomite) uncalcined b) diatomaceous earth (diatomite) calcined c) synthetic amorphous silica (precipitated and gel) d) fused silica (quartz glass) Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"Grafit a) grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna: a) ziemia okrzemkowa (diatomit) niekalcynowana b) ziemia okrzemkowa (diatomit) kalcynowana c) krzemionka bezpostaciowa syntetyczna (strącona i żel) d) krzemionka stopiona (szkło kwarcowe)"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,08 - 7,31) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a5dc9c0f1c10c8ce825f316","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn","methodology_en":"Concentration of manganese and its inorganic compounds calculated as Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,03 - 2,10) mg/m3"}],"parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,03 - 2,10) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,03 - 2,10) mg/m3\nMetoda spektrofotometryczna","reference":"Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","norm_bases":["Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,03 - 2,10) mg/m3\nMetoda spektrofotometryczna Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r. Srodowisko pracy − powietrze Stezenie manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,03 - 2,10) mg/m3\nMetoda spektrofotometryczna Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of manganese and its inorganic compounds calculated as Mn Spectrophotometric method inhalable fraction respirable fraction Range Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,03 - 2,10) mg/m3"}],"search_zh":"工作环境 − 空气 锰及其无机化合物浓度（以 Mn 计） 分光光度法 可吸入组分 呼吸性组分 范围 Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"锰及其无机化合物浓度（以 Mn 计）"},{"_id":"6a5dc9c0f1c10c8ce825f317","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie tlenków żelaza w przeliczeniu na Fe","methodology_en":"Concentration of iron oxides calculated as Fe","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,2 - 11,1) mg/m3"}],"parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,2 - 11,1) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie tlenków żelaza w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,2 - 11,1) mg/m3\nMetoda spektrofotometryczna","reference":"Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","norm_bases":["Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie tlenków żelaza w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,2 - 11,1) mg/m3\nMetoda spektrofotometryczna Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r. Srodowisko pracy − powietrze Stezenie tlenkow zelaza w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,2 - 11,1) mg/m3\nMetoda spektrofotometryczna Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of iron oxides calculated as Fe Spectrophotometric method inhalable fraction respirable fraction Range Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,2 - 11,1) mg/m3"}],"search_zh":"工作环境 − 空气 铁氧化物浓度（以 Fe 计） 分光光度法 可吸入组分 呼吸性组分 范围 Procedura Badawcza PB-02 wydanie 4 z dnia 21.08.2018 r.","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"铁氧化物浓度（以 Fe 计）"},{"_id":"6a5dc9c0f1c10c8ce825f318","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie chlorowodoru","methodology_en":"Hydrogen chloride concentration","parameters":[{"name":"Zakres","range":"(0,4 - 16,7)mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,4 - 16,7)mg/m3"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorowodoru\nZakres (0,4 - 16,7)mg/m3\nMetoda turbidymetryczna","reference":"PN-93/Z-04225/03","norm_bases":["PN-93/Z-04225/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie chlorowodoru\nZakres (0,4 - 16,7)mg/m3\nMetoda turbidymetryczna PN-93/Z-04225/03 Srodowisko pracy − powietrze Stezenie chlorowodoru\nZakres (0,4 - 16,7)mg/m3\nMetoda turbidymetryczna PN-93/Z-04225/03","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Hydrogen chloride concentration Turbidimetric method Range PN-93/Z-04225/03","parameters_zh":[{"name":"范围","range":"(0,4 - 16,7)mg/m3"}],"search_zh":"工作环境 − 空气 氯化氢浓度 浊度法 范围 PN-93/Z-04225/03","test_object_zh":"工作环境 − 空气","technique_zh":"浊度法","methodology_zh":"氯化氢浓度"},{"_id":"6a5dc9c0f1c10c8ce825f319","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie amoniaku","methodology_en":"Ammonia concentration","parameters":[{"name":"Zakres","range":"(1,0 - 40,0) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,0 - 40,0) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie amoniaku\nZakres (1,0 - 40,0) mg/m3\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie amoniaku\nZakres (1,0 - 40,0) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy − powietrze Stezenie amoniaku\nZakres (1,0 - 40,0) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Ammonia concentration Spectrophotometric method Range PN-71/Z-04041","parameters_zh":[{"name":"范围","range":"(1,0 - 40,0) mg/m3"}],"search_zh":"工作环境 − 空气 氨浓度 分光光度法 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氨浓度"},{"_id":"6a5dc9c0f1c10c8ce825f31a","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie tlenku azotu","methodology_en":"Nitrogen oxide concentration","parameters":[{"name":"Zakres","range":"(0,13 - 10,5) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,13 - 10,5) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu\nZakres (0,13 - 10,5) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie tlenku azotu\nZakres (0,13 - 10,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie tlenku azotu\nZakres (0,13 - 10,5) mg/m3\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Nitrogen oxide concentration Spectrophotometric method Range PN-Z-04009-11:2008","parameters_zh":[{"name":"范围","range":"(0,13 - 10,5) mg/m3"}],"search_zh":"工作环境 − 空气 一氧化氮浓度 分光光度法 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"一氧化氮浓度"},{"_id":"6a5dc9c0f1c10c8ce825f31b","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie ditlenku azotu","methodology_en":"Nitrogen dioxide concentration","parameters":[{"name":"Zakres","range":"(0,04 - 3,2) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,04 - 3,2) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ditlenku azotu\nZakres (0,04 - 3,2) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie ditlenku azotu\nZakres (0,04 - 3,2) mg/m3\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie ditlenku azotu\nZakres (0,04 - 3,2) mg/m3\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Nitrogen dioxide concentration Spectrophotometric method Range PN-Z-04009-11:2008","parameters_zh":[{"name":"范围","range":"(0,04 - 3,2) mg/m3"}],"search_zh":"工作环境 − 空气 二氧化氮浓度 分光光度法 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"二氧化氮浓度"},{"_id":"6a5dc9c0f1c10c8ce825f31c","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie formaldehydu","methodology_en":"Formaldehyde concentration","parameters":[{"name":"Zakres","range":"(0,025 - 2,00) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,025 - 2,00) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie formaldehydu\nZakres (0,025 - 2,00) mg/m3\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045-04","norm_bases":["PN-76/Z-04045-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie formaldehydu\nZakres (0,025 - 2,00) mg/m3\nMetoda spektrofotometryczna PN-76/Z-04045-04 Srodowisko pracy − powietrze Stezenie formaldehydu\nZakres (0,025 - 2,00) mg/m3\nMetoda spektrofotometryczna PN-76/Z-04045-04","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Formaldehyde concentration Spectrophotometric method Range PN-76/Z-04045-04","parameters_zh":[{"name":"范围","range":"(0,025 - 2,00) mg/m3"}],"search_zh":"工作环境 − 空气 甲醛浓度 分光光度法 范围 PN-76/Z-04045-04","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"甲醛浓度"},{"_id":"6a5dc9c0f1c10c8ce825f31d","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie chloru","methodology_en":"Chlorine concentration","parameters":[{"name":"Zakres","range":"(0,07 - 5,00) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,07 - 5,00) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru\nZakres (0,07 - 5,00) mg/m3\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03","norm_bases":["PN-75/Z-04037/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie chloru\nZakres (0,07 - 5,00) mg/m3\nMetoda spektrofotometryczna PN-75/Z-04037/03 Srodowisko pracy − powietrze Stezenie chloru\nZakres (0,07 - 5,00) mg/m3\nMetoda spektrofotometryczna PN-75/Z-04037/03","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Chlorine concentration Spectrophotometric method Range PN-75/Z-04037/03","parameters_zh":[{"name":"范围","range":"(0,07 - 5,00) mg/m3"}],"search_zh":"工作环境 − 空气 氯浓度 分光光度法 范围 PN-75/Z-04037/03","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氯浓度"},{"_id":"6a5dc9c0f1c10c8ce825f31e","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie siarkowodoru","methodology_en":"Hydrogen sulphide concentration","parameters":[{"name":"Zakres","range":"(0,5 - 26,7) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 - 26,7) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarkowodoru\nZakres (0,5 - 26,7) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996","norm_bases":["PN-Z-04015-13:1996"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie siarkowodoru\nZakres (0,5 - 26,7) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-13:1996 Srodowisko pracy − powietrze Stezenie siarkowodoru\nZakres (0,5 - 26,7) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-13:1996","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Hydrogen sulphide concentration Spectrophotometric method Range PN-Z-04015-13:1996","parameters_zh":[{"name":"范围","range":"(0,5 - 26,7) mg/m3"}],"search_zh":"工作环境 − 空气 硫化氢浓度 分光光度法 范围 PN-Z-04015-13:1996","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"硫化氢浓度"},{"_id":"6a5dc9c0f1c10c8ce825f31f","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie metanolu","methodology_en":"Methanol concentration","parameters":[{"name":"Zakres","range":"(4 - 500) mg/m3"}],"parameters_en":[{"name":"Range","range":"(4 - 500) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie metanolu\nZakres (4 - 500) mg/m3\nMetoda spektrofotometryczna","reference":"PN-66/Z-04038","norm_bases":["PN-66/Z-04038"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie metanolu\nZakres (4 - 500) mg/m3\nMetoda spektrofotometryczna PN-66/Z-04038 Srodowisko pracy − powietrze Stezenie metanolu\nZakres (4 - 500) mg/m3\nMetoda spektrofotometryczna PN-66/Z-04038","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Methanol concentration Spectrophotometric method Range PN-66/Z-04038","parameters_zh":[{"name":"范围","range":"(4 - 500) mg/m3"}],"search_zh":"工作环境 − 空气 甲醇浓度 分光光度法 范围 PN-66/Z-04038","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"甲醇浓度"},{"_id":"6a5dc9c0f1c10c8ce825f320","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie ozonu","methodology_en":"Ozone concentration","parameters":[{"name":"Zakres","range":"(0,014 - 0,200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,014 - 0,200) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ozonu\nZakres (0,014 - 0,200) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie ozonu\nZakres (0,014 - 0,200) mg/m3\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy − powietrze Stezenie ozonu\nZakres (0,014 - 0,200) mg/m3\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Ozone concentration Spectrophotometric method Range PN-Z-04007-2:1994","parameters_zh":[{"name":"范围","range":"(0,014 - 0,200) mg/m3"}],"search_zh":"工作环境 − 空气 臭氧浓度 分光光度法 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"臭氧浓度"},{"_id":"6a5dc9c0f1c10c8ce825f321","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,32 - 133) mg/m3"}],"parameters_en":[{"name":"Range","range":"(2,32 - 133) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres (2,32 - 133) mg/m3\nMetoda elektrochemiczna","reference":"Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","norm_bases":["Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie tlenku węgla\nZakres (2,32 - 133) mg/m3\nMetoda elektrochemiczna Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r. Srodowisko pracy − powietrze Stezenie tlenku wegla\nZakres (2,32 - 133) mg/m3\nMetoda elektrochemiczna Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Carbon monoxide concentration Electrochemical method Range Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","parameters_zh":[{"name":"范围","range":"(2,32 - 133) mg/m3"}],"search_zh":"工作环境 − 空气 一氧化碳浓度 电化学法 范围 Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a5dc9c0f1c10c8ce825f322","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","norm_bases":["Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r. Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure index (calculated) Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） Procedura Badawcza PB-03 wydanie 3 z dnia 05.09.2008 r.","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9c0f1c10c8ce825f323","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(0,5 - 10 000) lx"}],"parameters_en":[{"name":"Range","range":"(0,5 - 10 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 10 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040/03","norm_bases":["PN-83/E-04040/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 - 10 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040/03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 - 10 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040/03","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040/03","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 10 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040/03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9c0f1c10c8ce825f324","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040/03","norm_bases":["PN-83/E-04040/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040/03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040/03","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040/03","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040/03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9c0f1c10c8ce825f325","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","test_object_en":"Workplace environment - emergency lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(0,5 - 100) lx"}],"parameters_en":[{"name":"Range","range":"(0,5 - 100) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 100) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2025-05","norm_bases":["PN-EN 1838:2025-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 - 100) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2025-05 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 - 100) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2025-05","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method Range PN-EN 1838:2025-05","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 100) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 范围 PN-EN 1838:2025-05","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a5dc9c0f1c10c8ce825f326","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","test_object_en":"Workplace environment − cold microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(30 - 85) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 2,5) m/s"}],"parameters_en":[{"name":"Range","range":"(-30 - 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 - 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(30 - 85) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 2,5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (30 - 85) %\nPrędkość powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008+Ap1:2013","norm_bases":["PN-EN ISO 11079:2008+Ap1:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (30 - 85) %\nPrędkość powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008+Ap1:2013 Srodowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotnosc powietrza\nZakres (30 - 85) %\nPredkosc powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008+Ap1:2013","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008+Ap1:2013","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 - 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 - 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(30 - 85) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 2,5) m/s"}],"search_zh":"工作场所环境 − 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008+Ap1:2013","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f327","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","test_object_en":"Workplace environment − cold microclimate","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik tWC (z obliczeń)","methodology_en":"IREQmin index, IREQneutral index, tWC index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik tWC (z obliczeń)","reference":"PN-EN ISO 11079:2008+Ap1:2013","norm_bases":["PN-EN ISO 11079:2008+Ap1:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik tWC (z obliczeń) PN-EN ISO 11079:2008+Ap1:2013 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik tWC (z obliczen) PN-EN ISO 11079:2008+Ap1:2013","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − cold microclimate IREQmin index, IREQneutral index, tWC index (calculated) PN-EN ISO 11079:2008+Ap1:2013","search_zh":"工作场所环境 − 低温微气候 IREQmin 指数、IREQneutral 指数、tWC 指数（由计算得出） PN-EN ISO 11079:2008+Ap1:2013","test_object_zh":"工作场所环境 − 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、tWC 指数（由计算得出）"},{"_id":"6a5dc9c0f1c10c8ce825f328","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","test_object_en":"Workplace environment − hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 - 45) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 - 45) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 45) °C"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 2,5) m/s"}],"parameters_en":[{"name":"Range","range":"(10 - 45) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 - 45) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 45) °C"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 2,5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 45) °C\nTemperatura wilgotna naturalna\nZakres (10 - 45) °C\nTemperatura poczernionej kuli\nZakres (10 - 45) °C\nPrędkość powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 - 45) °C\nTemperatura wilgotna naturalna\nZakres (10 - 45) °C\nTemperatura poczernionej kuli\nZakres (10 - 45) °C\nPrędkość powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 - 45) °C\nTemperatura wilgotna naturalna\nZakres (10 - 45) °C\nTemperatura poczernionej kuli\nZakres (10 - 45) °C\nPredkosc powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range Air velocity Range PN-EN ISO 7243:2018-01","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 45) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 - 45) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 45) °C"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 2,5) m/s"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 空气流速 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f329","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","test_object_en":"Workplace environment − hot microclimate","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","methodology_en":"WBGT index, WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a5dc9c0f1c10c8ce825f32a","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","test_object_en":"Workplace environment − moderate microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(5 - 45) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 45) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(30 - 85) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 2,5) m/s"}],"parameters_en":[{"name":"Range","range":"(5 - 45) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 45) °C"},{"name":"Air humidity"},{"name":"Range","range":"(30 - 85) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 2,5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 - 45) °C\nTemperatura poczernionej kuli\nZakres (10 - 45) °C\nWilgotność powietrza\nZakres (30 - 85) %\nPrędkość powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 - 45) °C\nTemperatura poczernionej kuli\nZakres (10 - 45) °C\nWilgotność powietrza\nZakres (30 - 85) %\nPrędkość powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 - 45) °C\nTemperatura poczernionej kuli\nZakres (10 - 45) °C\nWilgotnosc powietrza\nZakres (30 - 85) %\nPredkosc powietrza\nZakres (0,15 - 2,5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 - 45) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 45) °C"},{"name":"空气湿度"},{"name":"范围","range":"(30 - 85) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 2,5) m/s"}],"search_zh":"工作场所环境 − 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a5dc9c0f1c10c8ce825f32b","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat umiarkowany","test_object_en":"Workplace environment − moderate microclimate","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index, PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy − mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 − 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 − 中等微气候"},{"_id":"6a5dc9c0f1c10c8ce825f32c","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment - hand-arm vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,01 - 25) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,01 - 25) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 - 25) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 - 25) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 - 25) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 - 25) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5dc9c0f1c10c8ce825f32d","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment - hand-arm vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of action vector sum of root-mean-square, frequency-corrected vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes and less, expressed as the vector sum of root-mean-square, frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent for 8 hours of action vector sum of root-mean-square, frequency-corrected vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes and less, expressed as the vector sum of root-mean-square, frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5dc9c0f1c10c8ce825f32e","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,06 - 100) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,06 - 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 - 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253 + A1:2011","norm_bases":["PN-EN 14253 + A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 - 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253 + A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,06 - 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253 + A1:2011","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253 + A1:2011","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,06 - 100) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253 + A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5dc9c0f1c10c8ce825f32f","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego ,ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego ,ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253 + A1:2011","norm_bases":["PN-EN 14253 + A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej wyrażona w postaci skutecznego ,ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253 + A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej wyrazona w postaci skutecznego ,wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253 + A1:2011","categories":["environment"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253 + A1:2011","search_zh":"工作场所环境 — 全身振动 PN-EN 14253 + A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5dc9c0f1c10c8ce825f330","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(24 - 134) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 - 137) dB"}],"parameters_en":[{"name":"Range","range":"(24 - 134) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 134) dB\nSzczytowy poziom dźwięku C\nZakres (50 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 134) dB\nSzczytowy poziom dźwięku C\nZakres (50 - 137) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (24 - 134) dB\nSzczytowy poziom dzwieku C\nZakres (50 - 137) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – p.10 i 11","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 - 134) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50 - 137) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9c0f1c10c8ce825f331","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – p.10 i 11","categories":["environment"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 − 噪声 噪声暴露级，参照： 每日 8 小时工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – p.10 i 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9c0f1c10c8ce825f332","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(24 - 134) dB"}],"parameters_en":[{"name":"Range","range":"(24 - 134) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (24 - 134) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24 - 134) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24 - 134) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wylaczeniem pkt. E.II.1 i pkt. F","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24 - 134) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9c0f1c10c8ce825f333","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wylaczeniem pkt. E.II.1 i pkt. F","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. E.II.1 i pkt. F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5dc9c0f1c10c8ce825f334","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(5 - 42) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 - 60) dm3/min"}],"parameters_en":[{"name":"Range","range":"(5 - 42) °C"},{"name":"Air flow"},{"name":"Range","range":"(10 - 60) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 - 42) °C\nPrzepływ powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","norm_bases":["Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 - 42) °C\nPrzepływ powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezpośrednia Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r. Srodowisko pracy - wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 - 42) °C\nPrzeplyw powietrza\nZakres (10 - 60) dm3/min\nMetoda pomiarowa bezposrednia Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - energy expenditure Air temperature Direct measurement method Range Air flow Range Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 - 42) °C"},{"name":"空气流量"},{"name":"范围","range":"(10 - 60) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 范围 空气流量 范围 Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5dc9c0f1c10c8ce825f335","lab_id":"69ad52a3de79e566650fb45c","country":"PL","accr_number":"AB 865","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Wydatek energetyczny (z obliczeń)","methodology_en":"Energy expenditure (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","norm_bases":["Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r. Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen) Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","categories":["environment"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated) Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） Procedura Badawcza PB-13 wydanie 1 z dnia 02.07.2018 r.","test_object_zh":"工作场所环境 — 能量消耗"}],"has_pdf":true}