{"lab":{"_id":"69ad52a3de79e566650fb44e","accr_number":"AB 851","country":"PL","accr_body":"PCA","address":"– PAŃSTWOWY INSTYTUT BADAWCZY, ZAKŁAD BADANIA POZOSTAŁOŚCI ŚRODKÓW OCHRONY ROŚLIN, ul. Władysława Węgorka 20, 60-318 Poznań","categories":["food","water","environment"],"city":"Poznań","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"INSTYTUT OCHRONY ROŚLIN","parse_status":"parsed","parse_version":3,"pdf_files":["AB_851.pdf"],"scope_summary":"","search_text":"instytut ochrony roślin – państwowy instytut badawczy, zakład badania pozostałości środków ochrony roślin, ul. władysława węgorka 20, 60-318 poznań food water environment other metrology","status":"active","updated_at":"2026-03-08T14:51:44.311Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:21:06.825Z","location":{"type":"Point","coordinates":[16.9252,52.4064]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20851,podmiot.html","fields_of_testing":[{"codes":"C/1; C/22, C/28, C/31 C/55","pl":"Badania chemiczne produktów rolnych, żywności, wody, gleby, pasz dla zwierząt","en":"Chemical tests of agricultural products, food, water, soil, animal feedstuffs"}],"issue":{"no":"19","date":"10.04.2026"},"parse_date":"2026-08-18T01:21:06.825Z","parse_source":"agent-claude-code","map_coord":[52.395679,16.854893],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD BADANIA POZOSTAŁOŚCI ŚRODKÓW OCHRONY ROŚLIN","address":"ul. Władysława Węgorka 20","city":null,"postal":null}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/ffd068974177db5b9638168ce8ab5d87/AB%20851.pdf","has_zh":true,"has_en":true,"category_counts":{"food":5,"water":1,"environment":1},"category_scores":{"food":3.57,"water":0.14,"environment":0.14}},"methods":[{"_id":"6a83b382af14b9c0e7b20c2a","lab_id":"69ad52a3de79e566650fb44e","country":"PL","accr_number":"AB 851","accr_body":"PCA","test_object":"Żywność E, Produkty rolne, pasze E RE","methodology":"Zawartość pozostałości ditiokarbaminianów (wyrażone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)","parameters":[],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość pozostałości ditiokarbaminianów (wyrażone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)\nMetoda spektrofotometryczna","reference":"PB-04","norm_bases":["PB-04"],"lab_section":"Zakład Badania Pozostałości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (WE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021 v2026.","flexible":false,"search_text":"Żywność E, Produkty rolne, pasze E RE Zawartość pozostałości ditiokarbaminianów (wyrażone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)\nMetoda spektrofotometryczna PB-04 Zywnosc E, Produkty rolne, pasze E RE Zawartosc pozostalosci ditiokarbaminianow (wyrazone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)\nMetoda spektrofotometryczna PB-04","categories":["food"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"二硫代氨基甲酸盐残留含量（以 CS2 计，包括代森锰、代森锰锌、福美锌类、丙森锌、福美双与福美锌）","search_zh":"食品 E、农产品、饲料 E RE 二硫代氨基甲酸盐残留含量（以 CS2 计，包括代森锰、代森锰锌、福美锌类、丙森锌、福美双与福美锌） 分光光度法 植物保护产品残留检测所 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。 PB-04","technique_zh":"分光光度法","lab_section_zh":"植物保护产品残留检测所","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。","test_object_zh":"食品 E、农产品、饲料 E RE","methodology_en":"Content of dithiocarbamate residues (expressed as CS2, including maneb, mancozeb, metiram, propineb, thiram and ziram)","search_en":"Content of dithiocarbamate residues (expressed as CS2, including maneb, mancozeb, metiram, propineb, thiram and ziram) Spectrophotometric method PB-04","technique_en":"Spectrophotometric method"},{"_id":"6a83b382af14b9c0e7b20c2b","lab_id":"69ad52a3de79e566650fb44e","country":"PL","accr_number":"AB 851","accr_body":"PCA","test_object":"Żywność E, Produkty rolne, pasze E RE","methodology":"Pozostałości środków ochrony roślin oznaczane metodami pojedynczymi","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Pozostałości środków ochrony roślin oznaczane metodami pojedynczymi\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PB-05","norm_bases":["PB-05"],"lab_section":"Zakład Badania Pozostałości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (WE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021 v2026.","flexible":false,"search_text":"Żywność E, Produkty rolne, pasze E RE Pozostałości środków ochrony roślin oznaczane metodami pojedynczymi\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PB-05 Zywnosc E, Produkty rolne, pasze E RE Pozostalosci srodkow ochrony roslin oznaczane metodami pojedynczymi\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PB-05","categories":["food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"以单一方法测定的植物保护产品残留","search_zh":"食品 E、农产品、饲料 E RE 以单一方法测定的植物保护产品残留 液相色谱-串联质谱法（LC-MS/MS） 植物保护产品残留检测所 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。 PB-05","lab_section_zh":"植物保护产品残留检测所","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。","technique_zh":"液相色谱-串联质谱法（LC-MS/MS）","test_object_zh":"食品 E、农产品、饲料 E RE","methodology_en":"Plant protection product residues determined by single methods","search_en":"Plant protection product residues determined by single methods Liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) PB-05","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)"},{"_id":"6a83b382af14b9c0e7b20c2c","lab_id":"69ad52a3de79e566650fb44e","country":"PL","accr_number":"AB 851","accr_body":"PCA","test_object":"Żywność E, Produkty rolne, pasze E RE","methodology":"Pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)"],"computed":[],"activity":"Pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Zakład Badania Pozostałości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (WE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021 v2026.","flexible":false,"search_text":"Żywność E, Produkty rolne, pasze E RE Pozostałości środków ochrony roślin\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS) PN-EN 15662 Zywnosc E, Produkty rolne, pasze E RE Pozostalosci srodkow ochrony roslin\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS/MS) PN-EN 15662","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"植物保护产品残留","search_zh":"食品 E、农产品、饲料 E RE 植物保护产品残留 气相色谱-串联质谱法（GC-MS/MS） 植物保护产品残留检测所 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。 PN-EN 15662","lab_section_zh":"植物保护产品残留检测所","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。","technique_zh":"气相色谱-串联质谱法（GC-MS/MS）","test_object_zh":"食品 E、农产品、饲料 E RE","methodology_en":"Plant protection product residues","search_en":"Plant protection product residues Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) PN-EN 15662","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)"},{"_id":"6a83b382af14b9c0e7b20c2d","lab_id":"69ad52a3de79e566650fb44e","country":"PL","accr_number":"AB 851","accr_body":"PCA","test_object":"Żywność E, Produkty rolne, pasze E RE","methodology":"Pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej / ultrasprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej / ultrasprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Pozostałości środków ochrony roślin\nMetoda wysokosprawnej / ultrasprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Zakład Badania Pozostałości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (WE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021 v2026.","flexible":false,"search_text":"Żywność E, Produkty rolne, pasze E RE Pozostałości środków ochrony roślin\nMetoda wysokosprawnej / ultrasprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PN-EN 15662 Zywnosc E, Produkty rolne, pasze E RE Pozostalosci srodkow ochrony roslin\nMetoda wysokosprawnej / ultrasprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PN-EN 15662","categories":["food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"植物保护产品残留","search_zh":"食品 E、农产品、饲料 E RE 植物保护产品残留 高效／超高效液相色谱-串联质谱法（LC-MS/MS） 植物保护产品残留检测所 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。 PN-EN 15662","lab_section_zh":"植物保护产品残留检测所","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。","technique_zh":"高效／超高效液相色谱-串联质谱法（LC-MS/MS）","test_object_zh":"食品 E、农产品、饲料 E RE","methodology_en":"Plant protection product residues","search_en":"Plant protection product residues PN-EN 15662"},{"_id":"6a83b382af14b9c0e7b20c2e","lab_id":"69ad52a3de79e566650fb44e","country":"PL","accr_number":"AB 851","accr_body":"PCA","test_object":"Żywność E, Produkty rolne, pasze E, RE","methodology":"Zawartość pozostałości ditiokarbaminianów (wyrażone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)"],"computed":[],"activity":"Zawartość pozostałości ditiokarbaminianów (wyrażone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","reference":"PB-06","norm_bases":["PB-06"],"lab_section":"Zakład Badania Pozostałości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. RE) - Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów rozporządzenia (WE) nr 625/2017 Parlamentu Europejskiego i Rady z dnia 15 marca 2017 r. w sprawie kontroli urzędowych i innych czynności urzędowych przeprowadzanych w celu zapewnienia stosowania prawa żywnościowego i paszowego oraz zasad dotyczących zdrowia i dobrostanu zwierząt, zdrowia roślin i środków ochrony roślin (Dz. U. UE L 95/1 z 07.04.2017, z późn. zm.), rozporządzenia Parlamentu Europejskiego i Rady (UE) 2018/848 z dnia 30 maja 2018 roku w sprawie produkcji ekologicznej i znakowania produktów ekologicznych i uchylającego rozporządzenie Rady (WE) 834/2007 oraz dokumentu SANTE/11312/2021 v2026.","flexible":false,"search_text":"Żywność E, Produkty rolne, pasze E, RE Zawartość pozostałości ditiokarbaminianów (wyrażone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS) PB-06 Zywnosc E, Produkty rolne, pasze E, RE Zawartosc pozostalosci ditiokarbaminianow (wyrazone jako CS2, w tym maneb, mankozeb, metiram, propineb, tiuram i ziram)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS/MS) PB-06","categories":["food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"二硫代氨基甲酸盐残留含量（以 CS2 计，包括代森锰、代森锰锌、福美锌类、丙森锌、福美双与福美锌）","search_zh":"食品 E、农产品、饲料 E、RE 二硫代氨基甲酸盐残留含量（以 CS2 计，包括代森锰、代森锰锌、福美锌类、丙森锌、福美双与福美锌） 气相色谱-串联质谱法（GC-MS/MS） 植物保护产品残留检测所 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。 PB-06","lab_section_zh":"植物保护产品残留检测所","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。RE) - 已确认实验室的能力，并考虑了下列法规的适用要求：欧洲议会和理事会 2017 年 3 月 15 日第 (WE) 625/2017 号条例（关于为确保食品和饲料法以及动物健康与福利、植物健康和植物保护产品规则的实施而进行的官方管控和其他官方活动，欧盟公报 L 95/1，2017 年 4 月 7 日，及其后续修订）、欧洲议会和理事会 2018 年 5 月 30 日第 (UE) 2018/848 号条例（关于有机生产和有机产品标识，并废止理事会第 (WE) 834/2007 号条例）以及文件 SANTE/11312/2021 v2026。","technique_zh":"气相色谱-串联质谱法（GC-MS/MS）","test_object_zh":"食品 E、农产品、饲料 E、RE","methodology_en":"Content of dithiocarbamate residues (expressed as CS2, including maneb, mancozeb, metiram, propineb, thiram and ziram)","search_en":"Content of dithiocarbamate residues (expressed as CS2, including maneb, mancozeb, metiram, propineb, thiram and ziram) Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) PB-06","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)"},{"_id":"6a83b382af14b9c0e7b20c2f","lab_id":"69ad52a3de79e566650fb44e","country":"PL","accr_number":"AB 851","accr_body":"PCA","test_object":"Woda E","methodology":"Pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Zakład Badania Pozostałości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Pozostałości środków ochrony roślin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PN-EN 15662 Woda E Pozostalosci srodkow ochrony roslin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PN-EN 15662","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"植物保护产品残留","search_zh":"水 E 植物保护产品残留 高效液相色谱-串联质谱法（LC-MS/MS） 植物保护产品残留检测所 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。 PN-EN 15662","technique_zh":"高效液相色谱-串联质谱法（LC-MS/MS）","lab_section_zh":"植物保护产品残留检测所","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。","test_object_zh":"水 E","methodology_en":"Plant protection product residues","search_en":"Water E Plant protection product residues High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) PN-EN 15662","technique_en":"High-performance liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Water E"},{"_id":"6a83b382af14b9c0e7b20c30","lab_id":"69ad52a3de79e566650fb44e","country":"PL","accr_number":"AB 851","accr_body":"PCA","test_object":"Gleba E","methodology":"Pozostałości środków ochrony roślin","parameters":[],"technique":"Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","techniques":["Metoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)"],"computed":[],"activity":"Pozostałości środków ochrony roślin\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS)","reference":"PN-EN 15662","norm_bases":["PN-EN 15662"],"lab_section":"Zakład Badania Pozostałości Środków Ochrony Roślin","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Gleba E Pozostałości środków ochrony roślin\nMetoda chromatografii cieczowej z detekcją tandemową spektrometrią mas (LC-MS/MS) PN-EN 15662 Gleba E Pozostalosci srodkow ochrony roslin\nMetoda chromatografii cieczowej z detekcja tandemowa spektrometria mas (LC-MS/MS) PN-EN 15662","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"植物保护产品残留","search_zh":"土壤 E 植物保护产品残留 液相色谱-串联质谱法（LC-MS/MS） 植物保护产品残留检测所 E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。 PN-EN 15662","lab_section_zh":"植物保护产品残留检测所","regulatory_area_zh":"E – 灵活认可范围。范围的灵活性涵盖 PCA 文件 DA-10 中针对检测实验室认可范围所指出的要素。在灵活认可范围内开展的检测清单由获认可机构公开提供或应要求提供。","technique_zh":"液相色谱-串联质谱法（LC-MS/MS）","test_object_zh":"土壤 E","methodology_en":"Plant protection product residues","search_en":"Soil E Plant protection product residues Liquid chromatography with tandem mass spectrometry detection (LC-MS/MS) PN-EN 15662","technique_en":"Liquid chromatography with tandem mass spectrometry detection (LC-MS/MS)","test_object_en":"Soil E"}],"has_pdf":true}