{"lab":{"_id":"69ad52a3de79e566650fb440","accr_number":"AB 842","country":"PL","accr_body":"PCA","address":"I KANALIZACJI W ŚWIDNICY Sp. z o.o., ul. Wrocławska 10, 58-100 Świdnica, LABORATORIUM","categories":["water","microbiology"],"city":"Świdnica","imported_at":"2026-03-08T10:42:43.265Z","methods_count":81,"name":"ŚWIDNICKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW","parse_status":"parsed","parse_version":3,"pdf_files":["AB_842.pdf"],"scope_summary":"","search_text":"świdnickie przedsiębiorstwo wodociągów i kanalizacji w świdnicy sp. z o.o., ul. wrocławska 10, 58-100 świdnica, laboratorium water microbiology other environment automotive materials","status":"active","updated_at":"2026-03-08T14:51:43.759Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:25:18.816Z","location":{"type":"Point","coordinates":[16.487,50.846]},"email_confidence":"high","email_mx":true,"email_source":"https://www.spwik.swidnica.pl/kontakt","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne oraz pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów ściekowych,","en":"Chemical tests and sampling of water, drinking water, sewage, sediments,"},{"codes":"K/28/P; K/29/P; K/32/P","pl":"Badania mikrobiologiczne oraz pobieranie próbek wody, wody do spożycia przez ludzi, osadów ściekowych,","en":"Microbiological tests and sampling of water, drinking water, sediments,"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych oraz pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów ściekowych,","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil"}],"issue":{"no":"24","date":"31.07.2026"},"parse_date":"2026-08-18T01:25:18.816Z","parse_source":"agent-claude-code","map_coord":[50.842939,16.49483],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":"Zawiszów 5","city":"Świdnica","postal":"58-100"}],"scope_format":"PCA::pracownie+siatka7","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/c9eb0e43e5c37007febbc9069ebd7334/AB%20842.pdf","has_en":true,"category_counts":{"water":81,"microbiology":5,"materials":4},"category_scores":{"water":72.9,"microbiology":0.28,"materials":0.18},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":"Zawiszów 5","city":"Świdnica","postal":"58-100"}]},"methods":[{"_id":"6a83b47faf14b9c0e7b20c3e","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 +Ap1:2019-07","norm_bases":["PN-ISO 5667-5:2017-10 +Ap1:2019-07"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 +Ap1:2019-07 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 +Ap1:2019-07","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 +Ap1:2019-07","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 +Ap1:2019-07","test_object_zh":"生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c3f","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(- 1,0 – 80,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (- 1,0 – 80,0) 0C","reference":"PB-34-01 z dnia 14.04.2025","norm_bases":["PB-34-01 z dnia 14.04.2025"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres (- 1,0 – 80,0) 0C PB-34-01 z dnia 14.04.2025 Woda do spozycia przez ludzi Temperatura\nZakres (- 1,0 – 80,0) 0C PB-34-01 z dnia 14.04.2025","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(- 1,0 – 80,0) 0C"}],"search_en":"Water intended for human consumption Temperature Range PB-34-01 z dnia 14.04.2025","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(- 1,0 – 80,0) 0C"}],"search_zh":"生活饮用水 温度 范围 PB-34-01 z dnia 14.04.2025","test_object_zh":"生活饮用水","methodology_zh":"温度"},{"_id":"6a83b47faf14b9c0e7b20c40","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 +Ap1:2019-07 | IB-01-01 z dnia 19.08.2019","norm_bases":["PN-ISO 5667-5:2017-10 +Ap1:2019-07","IB-01-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 +Ap1:2019-07 | IB-01-01 z dnia 19.08.2019 Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 +Ap1:2019-07 | IB-01-01 z dnia 19.08.2019","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Swimming pool water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 +Ap1:2019-07 | IB-01-01 z dnia 19.08.2019","test_object_en":"Swimming pool water","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 +Ap1:2019-07 | IB-01-01 z dnia 19.08.2019","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c41","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(15,0 – 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (15,0 – 50,0) 0C","reference":"PB-34-01 z dnia 14.04.2025","norm_bases":["PB-34-01 z dnia 14.04.2025"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Temperatura\nZakres (15,0 – 50,0) 0C PB-34-01 z dnia 14.04.2025 Woda na plywalniach Temperatura\nZakres (15,0 – 50,0) 0C PB-34-01 z dnia 14.04.2025","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(15,0 – 50,0) 0C"}],"search_en":"Swimming pool water Temperature Range PB-34-01 z dnia 14.04.2025","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(15,0 – 50,0) 0C"}],"search_zh":"游泳池水 温度 范围 PB-34-01 z dnia 14.04.2025","test_object_zh":"游泳池水","methodology_zh":"温度"},{"_id":"6a83b47faf14b9c0e7b20c42","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water (including swimming pool water), Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水（含游泳池水）、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c43","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, p. 8.2, p. 9.3, p. 9.4","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, p. 8.2, p. 9.3, p. 9.4"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, p. 8.2, p. 9.3, p. 9.4 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem p. 7.5, p. 8.2, p. 9.3, p. 9.4","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, p. 8.2, p. 9.3, p. 9.4","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.5, p. 8.2, p. 9.3, p. 9.4","test_object_zh":"水"},{"_id":"6a83b47faf14b9c0e7b20c44","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"( -1,0 – 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres ( -1,0 – 50,0) 0C","reference":"PB-34-01 z dnia 14.04.2025","norm_bases":["PB-34-01 z dnia 14.04.2025"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres ( -1,0 – 50,0) 0C PB-34-01 z dnia 14.04.2025 Woda Temperatura\nZakres ( -1,0 – 50,0) 0C PB-34-01 z dnia 14.04.2025","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"( -1,0 – 50,0) 0C"}],"search_en":"Water Temperature Range PB-34-01 z dnia 14.04.2025","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"( -1,0 – 50,0) 0C"}],"search_zh":"水 温度 范围 PB-34-01 z dnia 14.04.2025","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a83b47faf14b9c0e7b20c45","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a83b47faf14b9c0e7b20c46","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 50,0) 0C","reference":"PB-34-01 z dnia 14.04.2025","norm_bases":["PB-34-01 z dnia 14.04.2025"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (5,0 – 50,0) 0C PB-34-01 z dnia 14.04.2025 Scieki Temperatura\nZakres (5,0 – 50,0) 0C PB-34-01 z dnia 14.04.2025","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5,0 – 50,0) 0C"}],"search_en":"Wastewater Temperature Range PB-34-01 z dnia 14.04.2025","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 50,0) 0C"}],"search_zh":"污水 温度 范围 PB-34-01 z dnia 14.04.2025","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a83b47faf14b9c0e7b20c47","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, p. 6.3.4, p. 6.3.5, p. 6.3.7, p. 6.3.8, p. 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, p. 6.3.4, p. 6.3.5, p. 6.3.7, p. 6.3.8, p. 6.3.10"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, p. 6.3.4, p. 6.3.5, p. 6.3.7, p. 6.3.8, p. 6.3.10 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem p. 6.3.3, p. 6.3.4, p. 6.3.5, p. 6.3.7, p. 6.3.8, p. 6.3.10","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, p. 6.3.4, p. 6.3.5, p. 6.3.7, p. 6.3.8, p. 6.3.10","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3, p. 6.3.4, p. 6.3.5, p. 6.3.7, p. 6.3.8, p. 6.3.10","test_object_zh":"污泥"},{"_id":"6a83b47faf14b9c0e7b20c48","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań biologicznych","reference":"PN-EN ISO 5667-13:2011 p. 6.3.2.2","norm_bases":["PN-EN ISO 5667-13:2011 p. 6.3.2.2"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań biologicznych PN-EN ISO 5667-13:2011 p. 6.3.2.2 Osady sciekowe Pobieranie probek do badan biologicznych PN-EN ISO 5667-13:2011 p. 6.3.2.2","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for biological testing","search_en":"Sewage sludge Sampling for biological testing PN-EN ISO 5667-13:2011 p. 6.3.2.2","test_object_en":"Sewage sludge","search_zh":"污泥 PN-EN ISO 5667-13:2011 p. 6.3.2.2","test_object_zh":"污泥"},{"_id":"6a83b47faf14b9c0e7b20c49","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 360C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 360C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 360C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 360C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 360C","search_en":"Water, Water intended for human consumption Total microorganism count at 360C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"36°C 微生物总数"},{"_id":"6a83b47faf14b9c0e7b20c4a","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 220C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 220C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 220C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 220C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 220C","search_en":"Water, Water intended for human consumption Total count of microorganisms at 220C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c4b","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c4c","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c4d","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c4e","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c4f","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego +","parameters":[{"name":"Zakres","range":"(0,10 – 4,6) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna","reference":"PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","norm_bases":["PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica; Badania wykonywane w siedzibie i poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260 Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration +","parameters_en":[{"name":"Range","range":"(0,10 – 4,6) mg/l"}],"search_en":"Water, Water intended for human consumption Free chlorine concentration + Colorimetric method Range PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_en":"Colorimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 4,6) mg/l"}],"search_zh":"水、生活饮用水 比色法 范围 PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_zh":"比色法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c50","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru ogólnego +","parameters":[{"name":"Zakres","range":"(0,10 – 4,6) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna","reference":"PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","norm_bases":["PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica; Badania wykonywane w siedzibie i poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru ogólnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260 Woda, Woda do spozycia przez ludzi Stezenie chloru ogolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration +","parameters_en":[{"name":"Range","range":"(0,10 – 4,6) mg/l"}],"search_en":"Water, Water intended for human consumption Total chlorine concentration + Colorimetric method Range PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_en":"Colorimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 4,6) mg/l"}],"search_zh":"水、生活饮用水 比色法 范围 PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_zh":"比色法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c51","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie choru związanego Stężenie chloramin (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie choru związanego Stężenie chloramin (z obliczeń)","reference":"PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","norm_bases":["PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie choru związanego Stężenie chloramin (z obliczeń) PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260 Woda, Woda do spozycia przez ludzi Stezenie choru zwiazanego Stezenie chloramin (z obliczen) PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c52","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 500) mg/l\nMetoda spektrofotometryczna","reference":"PB-17-02 z dnia 23.07.2021 na podstawie metody HACH 8025","norm_bases":["PB-17-02 z dnia 23.07.2021 na podstawie metody HACH 8025"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 500) mg/l\nMetoda spektrofotometryczna PB-17-02 z dnia 23.07.2021 na podstawie metody HACH 8025 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 500) mg/l\nMetoda spektrofotometryczna PB-17-02 z dnia 23.07.2021 na podstawie metody HACH 8025","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PB-17-02 z dnia 23.07.2021 na podstawie metody HACH 8025","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PB-17-02 z dnia 23.07.2021 na podstawie metody HACH 8025","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c53","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,18 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,18 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PB-11-02 z dnia 23.07.2021 na podstawie metody HACH 8038","norm_bases":["PB-11-02 z dnia 23.07.2021 na podstawie metody HACH 8038"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres (0,18 – 50) mg/l\nMetoda spektrofotometryczna PB-11-02 z dnia 23.07.2021 na podstawie metody HACH 8038 Woda, Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres (0,18 – 50) mg/l\nMetoda spektrofotometryczna PB-11-02 z dnia 23.07.2021 na podstawie metody HACH 8038","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,18 – 50) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium nitrogen concentration Spectrophotometric method Range PB-11-02 z dnia 23.07.2021 na podstawie metody HACH 8038","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,18 – 50) mg/l"}],"search_zh":"水、生活饮用水 氨氮浓度 分光光度法 范围 PB-11-02 z dnia 23.07.2021 na podstawie metody HACH 8038","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c54","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/l"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c55","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c56","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń)","reference":"IB-02-01 z dnia 19.08.2019","norm_bases":["IB-02-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń) IB-02-01 z dnia 19.08.2019 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) (z obliczen) IB-02-01 z dnia 19.08.2019","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total calcium and magnesium content (total hardness) (calculated)","search_en":"Water, Water intended for human consumption Total calcium and magnesium content (total hardness) (calculated) IB-02-01 z dnia 19.08.2019","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 钙与镁总含量（总硬度）（由计算得出） IB-02-01 z dnia 19.08.2019","test_object_zh":"水、生活饮用水","methodology_zh":"钙与镁总含量（总硬度）（由计算得出）"},{"_id":"6a83b47faf14b9c0e7b20c57","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10 – 1 000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 – 1 000) mg/l CaCO3\nMetoda miareczkowa","reference":"PB-22-01 z dnia 19.08.2019 na podstawie metody HACH 8213","norm_bases":["PB-22-01 z dnia 19.08.2019 na podstawie metody HACH 8213"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 – 1 000) mg/l CaCO3\nMetoda miareczkowa PB-22-01 z dnia 19.08.2019 na podstawie metody HACH 8213 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10 – 1 000) mg/l CaCO3\nMetoda miareczkowa PB-22-01 z dnia 19.08.2019 na podstawie metody HACH 8213","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10 – 1 000) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PB-22-01 z dnia 19.08.2019 na podstawie metody HACH 8213","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10 – 1 000) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PB-22-01 z dnia 19.08.2019 na podstawie metody HACH 8213","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c58","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Twardość węglanowa i niewęglanowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość węglanowa i niewęglanowa (z obliczeń)","reference":"IB-03-01 z dnia 19.08.2019","norm_bases":["IB-03-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Twardość węglanowa i niewęglanowa (z obliczeń) IB-03-01 z dnia 19.08.2019 Woda, Woda do spozycia przez ludzi Twardosc weglanowa i nieweglanowa (z obliczen) IB-03-01 z dnia 19.08.2019","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbonate and non-carbonate hardness (calculated)","search_en":"Water, Water intended for human consumption Carbonate and non-carbonate hardness (calculated) IB-03-01 z dnia 19.08.2019","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 IB-03-01 z dnia 19.08.2019","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c59","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(15 – 800) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (15 – 800) mg/l\nMetoda turbidymetryczna","reference":"PB-19-02 z dnia 01.06.2021 na podstawie metody HACH 8051","norm_bases":["PB-19-02 z dnia 01.06.2021 na podstawie metody HACH 8051"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (15 – 800) mg/l\nMetoda turbidymetryczna PB-19-02 z dnia 01.06.2021 na podstawie metody HACH 8051 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (15 – 800) mg/l\nMetoda turbidymetryczna PB-19-02 z dnia 01.06.2021 na podstawie metody HACH 8051","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(15 – 800) mg/l"}],"search_en":"Water, Water intended for human consumption Sulfate concentration Turbidimetric method Range PB-19-02 z dnia 01.06.2021 na podstawie metody HACH 8051","technique_en":"Turbidimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(15 – 800) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 浊度法 范围 PB-19-02 z dnia 01.06.2021 na podstawie metody HACH 8051","test_object_zh":"水、生活饮用水","technique_zh":"浊度法"},{"_id":"6a83b47faf14b9c0e7b20c5a","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu","parameters":[{"name":"Zakres","range":"(0,20 – 200) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie magnezu\nZakres (0,20 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu\nZakres (0,20 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda, Woda do spozycia przez ludzi Stezenie magnezu\nZakres (0,20 – 200) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration","parameters_en":[{"name":"Range","range":"(0,20 – 200) mg/l"}],"search_en":"Water, Water intended for human consumption Magnesium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,20 – 200) mg/l"}],"search_zh":"水、生活饮用水 镁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度"},{"_id":"6a83b47faf14b9c0e7b20c5b","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie metali","parameters":[{"name":"mangan","range":"(2,00 – 1000) µg/l"},{"name":"glin","range":"(10,0 – 1000) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nmangan (2,00 – 1000) µg/l\nglin (10,0 – 1000) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie metali\nZakres:\nmangan (2,00 – 1000) µg/l\nglin (10,0 – 1000) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi Stezenie metali\nZakres:\nmangan (2,00 – 1000) µg/l\nglin (10,0 – 1000) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"manganese","range":"(2,00 – 1000) µg/l"},{"name":"aluminium","range":"(10,0 – 1000) μg/l"}],"search_en":"Water, Water intended for human consumption Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) manganese aluminium PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"金属浓度","search_zh":"水、生活饮用水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 锰 铝 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"锰","range":"(2,00 – 1000) µg/l"},{"name":"铝","range":"(10,0 – 1000) μg/l"}]},{"_id":"6a83b47faf14b9c0e7b20c5c","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,0200 – 10,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (0,0200 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,0200 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,0200 – 10,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,0200 – 10,0) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,0200 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b47faf14b9c0e7b20c5d","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie potasu","parameters":[{"name":"Zakres","range":"(1,00 – 25,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie potasu\nZakres (1,00 – 25,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN- ISO 9964-2:1994","norm_bases":["PN- ISO 9964-2:1994"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie potasu\nZakres (1,00 – 25,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN- ISO 9964-2:1994 Woda, Woda do spozycia przez ludzi Stezenie potasu\nZakres (1,00 – 25,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN- ISO 9964-2:1994","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium concentration","parameters_en":[{"name":"Range","range":"(1,00 – 25,0) mg/l"}],"search_en":"Water, Water intended for human consumption Potassium concentration Flame atomic absorption spectrometry (FAAS) Range PN- ISO 9964-2:1994","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,00 – 25,0) mg/l"}],"search_zh":"水、生活饮用水 钾浓度 火焰原子吸收光谱法（FAAS） 范围 PN- ISO 9964-2:1994","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钾浓度"},{"_id":"6a83b47faf14b9c0e7b20c5e","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(5,00 – 500) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie sodu\nZakres (5,00 – 500) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+Ap1:2009","norm_bases":["PN-ISO 9964-1:1994+Ap1:2009"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie sodu\nZakres (5,00 – 500) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009 Woda, Woda do spozycia przez ludzi Stezenie sodu\nZakres (5,00 – 500) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium concentration","parameters_en":[{"name":"Range","range":"(5,00 – 500) mg/l"}],"search_en":"Water, Water intended for human consumption Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+Ap1:2009","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5,00 – 500) mg/l"}],"search_zh":"水、生活饮用水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钠浓度"},{"_id":"6a83b47faf14b9c0e7b20c5f","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(0,50 – 400) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie wapnia\nZakres (0,50 – 400) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (0,50 – 400) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (0,50 – 400) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(0,50 – 400) mg/l"}],"search_en":"Water, Water intended for human consumption Calcium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,50 – 400) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a83b47faf14b9c0e7b20c60","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w temp. 360C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 360C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 360C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 360C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 360C","search_en":"Swimming pool water Total microorganism count at 360C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Swimming pool water","search_zh":"游泳池水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","methodology_zh":"36°C 微生物总数"},{"_id":"6a83b47faf14b9c0e7b20c61","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c62","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c63","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,45 – 22,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,45 – 22,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","norm_bases":["PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie azotu azotanowego\nZakres (0,45 – 22,5) mg/l\nMetoda spektrofotometryczna PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339 Woda na plywalniach Stezenie azotu azotanowego\nZakres (0,45 – 22,5) mg/l\nMetoda spektrofotometryczna PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,45 – 22,5) mg/l"}],"search_en":"Swimming pool water Nitrate nitrogen concentration Spectrophotometric method Range PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,45 – 22,5) mg/l"}],"search_zh":"游泳池水 硝态氮浓度 分光光度法 范围 PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c64","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru wolnego +","parameters":[{"name":"Zakres","range":"(0,10 – 4,6) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna","reference":"PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","norm_bases":["PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica; Badania wykonywane w siedzibie i poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru wolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260 Woda na plywalniach Stezenie chloru wolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration +","parameters_en":[{"name":"Range","range":"(0,10 – 4,6) mg/l"}],"search_en":"Swimming pool water Free chlorine concentration + Colorimetric method Range PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_en":"Colorimetric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,10 – 4,6) mg/l"}],"search_zh":"游泳池水 比色法 范围 PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_zh":"比色法","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c65","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru ogólnego +","parameters":[{"name":"Zakres","range":"(0,10 – 4,6) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru ogólnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna","reference":"PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","norm_bases":["PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica; Badania wykonywane w siedzibie i poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru ogólnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260 Woda na plywalniach Stezenie chloru ogolnego +\nZakres (0,10 – 4,6) mg/l\nMetoda kolorymetryczna PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration +","parameters_en":[{"name":"Range","range":"(0,10 – 4,6) mg/l"}],"search_en":"Swimming pool water Total chlorine concentration + Colorimetric method Range PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_en":"Colorimetric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,10 – 4,6) mg/l"}],"search_zh":"游泳池水 比色法 范围 PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","technique_zh":"比色法","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c66","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie choru związanego Stężenie chloramin (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie choru związanego Stężenie chloramin (z obliczeń)","reference":"PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","norm_bases":["PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie choru związanego Stężenie chloramin (z obliczeń) PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260 Woda na plywalniach Stezenie choru zwiazanego Stezenie chloramin (z obliczen) PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Swimming pool water PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","test_object_en":"Swimming pool water","search_zh":"游泳池水 PB-29-02 z dnia 04.09.2019 na podstawie metody HACH 10260","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c67","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/l"}],"search_en":"Swimming pool water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Swimming pool water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/l"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c68","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda na plywalniach Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Swimming pool water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c69","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a83b47faf14b9c0e7b20c6a","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,45 – 22,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,45 – 22,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","norm_bases":["PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotanowego\nZakres (0,45 – 22,5) mg/l\nMetoda spektrofotometryczna PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotanowego\nZakres (0,45 – 22,5) mg/l\nMetoda spektrofotometryczna PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,45 – 22,5) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,45 – 22,5) mg/l"}],"search_zh":"水、生活饮用水、废水 硝态氮浓度 分光光度法 范围 PB-15-02 z dnia 23.07.2021 na podstawie metody HACH LANGE LCK 339","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a83b47faf14b9c0e7b20c6b","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"zakres","range":"(0,015 – 2,00) mg/l"}],"technique":"metoda spektrofotometryczna","techniques":["metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nzakres (0,015 – 2,00) mg/l\nmetoda spektrofotometryczna","reference":"PB-31-01 z dnia 01.06.2021 na podstawie metody HACH LANGE LCK 341","norm_bases":["PB-31-01 z dnia 01.06.2021 na podstawie metody HACH LANGE LCK 341"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nzakres (0,015 – 2,00) mg/l\nmetoda spektrofotometryczna PB-31-01 z dnia 01.06.2021 na podstawie metody HACH LANGE LCK 341 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nzakres (0,015 – 2,00) mg/l\nmetoda spektrofotometryczna PB-31-01 z dnia 01.06.2021 na podstawie metody HACH LANGE LCK 341","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"range","range":"(0,015 – 2,00) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration spectrophotometric method range PB-31-01 z dnia 01.06.2021 na podstawie metody HACH LANGE LCK 341","technique_en":"spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"亚硝态氮浓度","search_zh":"水、生活饮用水、废水 亚硝态氮浓度 范围 PB-31-01 z dnia 01.06.2021 na podstawie metody HACH LANGE LCK 341","test_object_zh":"水、生活饮用水、废水","parameters_zh":[{"name":"范围","range":"(0,015 – 2,00) mg/l"}]},{"_id":"6a83b47faf14b9c0e7b20c6c","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 5 000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 5 000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,00 – 5 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,00 – 5 000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 5 000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 5 000) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a83b47faf14b9c0e7b20c6d","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PB-18-01 z dnia 19.08.2019 na podstawie metody HACH 8029","norm_bases":["PB-18-01 z dnia 19.08.2019 na podstawie metody HACH 8029"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie fluorków\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PB-18-01 z dnia 19.08.2019 na podstawie metody HACH 8029 Woda, Woda do spozycia przez ludzi, Scieki Stezenie fluorkow\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PB-18-01 z dnia 19.08.2019 na podstawie metody HACH 8029","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 – 30) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Fluoride concentration Spectrophotometric method Range PB-18-01 z dnia 19.08.2019 na podstawie metody HACH 8029","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 30) mg/l"}],"search_zh":"水、生活饮用水、废水 氟化物浓度 分光光度法 范围 PB-18-01 z dnia 19.08.2019 na podstawie metody HACH 8029","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"氟化物浓度"},{"_id":"6a83b47faf14b9c0e7b20c6e","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(3,00 – 800) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (3,00 – 800) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie ogólnego węgla organicznego\nZakres (3,00 – 800) mg/l\nMetoda spektrofotometryczna PN-EN 1484:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie ogolnego wegla organicznego\nZakres (3,00 – 800) mg/l\nMetoda spektrofotometryczna PN-EN 1484:1999","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(3,00 – 800) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total organic carbon concentration Spectrophotometric method Range PN-EN 1484:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(3,00 – 800) mg/l"}],"search_zh":"水、生活饮用水、废水 总有机碳浓度 分光光度法 范围 PN-EN 1484:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"总有机碳浓度"},{"_id":"6a83b47faf14b9c0e7b20c6f","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH +","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH +\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica; Badania wykonywane w siedzibie i poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH +\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH +\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH +","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH + Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水、废水 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a83b47faf14b9c0e7b20c70","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Przewodność elektryczna właściwa +","parameters":[{"name":"Zakres","range":"(10 – 10 000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa +\nZakres (10 – 10 000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica; Badania wykonywane w siedzibie i poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Przewodność elektryczna właściwa +\nZakres (10 – 10 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki Przewodnosc elektryczna wlasciwa +\nZakres (10 – 10 000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity +","parameters_en":[{"name":"Range","range":"(10 – 10 000) µS/cm"}],"search_en":"Water, Water intended for human consumption, Wastewater Electrical conductivity + Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10 000) µS/cm"}],"search_zh":"水、生活饮用水、废水 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a83b47faf14b9c0e7b20c71","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(20 – 1 000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (20 – 1 000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zasadowość ogólna\nZakres (20 – 1 000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Woda do spozycia przez ludzi, Scieki Zasadowosc ogolna\nZakres (20 – 1 000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(20 – 1 000) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption, Wastewater Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(20 – 1 000) mg/l CaCO3"}],"search_zh":"水、生活饮用水、废水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"总碱度"},{"_id":"6a83b47faf14b9c0e7b20c72","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,050 – 10,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,050 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza\nZakres (0,050 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza\nZakres (0,050 – 10,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,050 – 10,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Iron concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 10,0) mg/l"}],"search_zh":"水、生活饮用水、废水 铁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a83b47faf14b9c0e7b20c73","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie miedzi","parameters":[{"name":"Zakres","range":"(0,050 – 15,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi\nZakres (0,050 – 15,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie miedzi\nZakres (0,050 – 15,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda, Woda do spozycia przez ludzi, Scieki Stezenie miedzi\nZakres (0,050 – 15,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper concentration","parameters_en":[{"name":"Range","range":"(0,050 – 15,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Copper concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 15,0) mg/l"}],"search_zh":"水、生活饮用水、废水 铜浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、废水","methodology_zh":"铜浓度"},{"_id":"6a83b47faf14b9c0e7b20c74","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie metali","parameters":[{"name":"arsen","range":"(3,0 – 250) µg/l"},{"name":"miedź","range":"(0,0020 – 2,0) mg/l"},{"name":"kadm","range":"(0,20 – 25) µg/l"},{"name":"ołów","range":"(3,0 – 750) µg/l"},{"name":"chrom","range":"(0,0010 – 5,0) mg/l"},{"name":"nikiel","range":"(0,0030 – 0,100) mg/l"},{"name":"żelazo","range":"(10,0 – 1500) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\narsen (3,0 – 250) µg/l\nmiedź (0,0020 – 2,0) mg/l\nkadm (0,20 – 25) µg/l\nołów (3,0 – 750) µg/l\nchrom (0,0010 – 5,0) mg/l\nnikiel (0,0030 – 0,100) mg/l\nżelazo (10,0 – 1500) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie metali\nZakres:\narsen (3,0 – 250) µg/l\nmiedź (0,0020 – 2,0) mg/l\nkadm (0,20 – 25) µg/l\nołów (3,0 – 750) µg/l\nchrom (0,0010 – 5,0) mg/l\nnikiel (0,0030 – 0,100) mg/l\nżelazo (10,0 – 1500) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Woda do spozycia przez ludzi, Scieki Stezenie metali\nZakres:\narsen (3,0 – 250) µg/l\nmiedz (0,0020 – 2,0) mg/l\nkadm (0,20 – 25) µg/l\nolow (3,0 – 750) µg/l\nchrom (0,0010 – 5,0) mg/l\nnikiel (0,0030 – 0,100) mg/l\nzelazo (10,0 – 1500) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"arsenic","range":"(3,0 – 250) µg/l"},{"name":"copper","range":"(0,0020 – 2,0) mg/l"},{"name":"cadmium","range":"(0,20 – 25) µg/l"},{"name":"lead","range":"(3,0 – 750) µg/l"},{"name":"chromium","range":"(0,0010 – 5,0) mg/l"},{"name":"nickel","range":"(0,0030 – 0,100) mg/l"},{"name":"iron","range":"(10,0 – 1500) μg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) arsenic copper cadmium lead chromium nickel iron PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"砷","range":"(3,0 – 250) µg/l"},{"name":"铜","range":"(0,0020 – 2,0) mg/l"},{"name":"镉","range":"(0,20 – 25) µg/l"},{"name":"铅","range":"(3,0 – 750) µg/l"},{"name":"铬","range":"(0,0010 – 5,0) mg/l"},{"name":"镍","range":"(0,0030 – 0,100) mg/l"},{"name":"铁","range":"(10,0 – 1500) μg/l"}],"search_zh":"水、生活饮用水、废水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 砷 铜 镉 铅 铬 镍 铁 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a83b47faf14b9c0e7b20c75","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"zakres","range":"(15 – 900) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nzakres (15 – 900) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nzakres (15 – 900) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nzakres (15 – 900) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"range","range":"(15 – 900) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Gravimetric method range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水","parameters_zh":[{"name":"范围","range":"(15 – 900) mg/l"}]},{"_id":"6a83b47faf14b9c0e7b20c76","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,00 – 1700) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,00 – 1700) mg/l\nMetoda spektrofotometryczna","reference":"PB-16-01 z dnia 19.08.2019 na podstawie metody HACH LANGE LCK 138, 238 i 338","norm_bases":["PB-16-01 z dnia 19.08.2019 na podstawie metody HACH LANGE LCK 138, 238 i 338"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (1,00 – 1700) mg/l\nMetoda spektrofotometryczna PB-16-01 z dnia 19.08.2019 na podstawie metody HACH LANGE LCK 138, 238 i 338 Woda, Scieki Stezenie azotu ogolnego\nZakres (1,00 – 1700) mg/l\nMetoda spektrofotometryczna PB-16-01 z dnia 19.08.2019 na podstawie metody HACH LANGE LCK 138, 238 i 338","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,00 – 1700) mg/l"}],"search_en":"Water, Wastewater Total nitrogen concentration Spectrophotometric method Range PB-16-01 z dnia 19.08.2019 na podstawie metody HACH LANGE LCK 138, 238 i 338","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 – 1700) mg/l"}],"search_zh":"水、污水 总氮浓度 分光光度法 范围 PB-16-01 z dnia 19.08.2019 na podstawie metody HACH LANGE LCK 138, 238 i 338","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b47faf14b9c0e7b20c77","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(2,0 – 6,0) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 6,0) mg/l\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 6,0) mg/l\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 6,0) mg/l\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(2,0 – 6,0) mg/l"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 6,0) mg/l"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b47faf14b9c0e7b20c78","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6 000) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6 000) mg/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6 000) mg/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6 000) mg/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6 000) mg/l"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6 000) mg/l"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b47faf14b9c0e7b20c79","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 25 000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 25 000) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 25 000) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10,0 – 25 000) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10,0 – 25 000) mg/l"}],"search_en":"Water, Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 25 000) mg/l"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a83b47faf14b9c0e7b20c7a","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,07 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,07 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PB-08-01 z dnia 19.08.2019 na podstawie metody HACH 8190","norm_bases":["PB-08-01 z dnia 19.08.2019 na podstawie metody HACH 8190"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,07 – 50) mg/l\nMetoda spektrofotometryczna PB-08-01 z dnia 19.08.2019 na podstawie metody HACH 8190 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,07 – 50) mg/l\nMetoda spektrofotometryczna PB-08-01 z dnia 19.08.2019 na podstawie metody HACH 8190","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,07 – 50) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PB-08-01 z dnia 19.08.2019 na podstawie metody HACH 8190","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,07 – 50) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PB-08-01 z dnia 19.08.2019 na podstawie metody HACH 8190","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b47faf14b9c0e7b20c7b","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"zakres","range":"(0,07 – 400) mg/l"}],"technique":"metoda spektrofotometryczna","techniques":["metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nzakres (0,07 – 400) mg/l\nmetoda spektrofotometryczna","reference":"PB-32-01 z dnia 01.06.2021 na podstawie metodyk HACH LANGE LCK 348, 349, 350","norm_bases":["PB-32-01 z dnia 01.06.2021 na podstawie metodyk HACH LANGE LCK 348, 349, 350"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nzakres (0,07 – 400) mg/l\nmetoda spektrofotometryczna PB-32-01 z dnia 01.06.2021 na podstawie metodyk HACH LANGE LCK 348, 349, 350 Woda, Scieki Stezenie fosforu ogolnego\nzakres (0,07 – 400) mg/l\nmetoda spektrofotometryczna PB-32-01 z dnia 01.06.2021 na podstawie metodyk HACH LANGE LCK 348, 349, 350","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"range","range":"(0,07 – 400) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration spectrophotometric method range PB-32-01 z dnia 01.06.2021 na podstawie metodyk HACH LANGE LCK 348, 349, 350","technique_en":"spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","search_zh":"水、污水 总磷浓度 范围 PB-32-01 z dnia 01.06.2021 na podstawie metodyk HACH LANGE LCK 348, 349, 350","test_object_zh":"水、污水","parameters_zh":[{"name":"范围","range":"(0,07 – 400) mg/l"}]},{"_id":"6a83b47faf14b9c0e7b20c7c","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10,0 – 10 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa","reference":"PB-23-01 z dnia 19.08.2019","norm_bases":["PB-23-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Sucha pozostałość\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa PB-23-01 z dnia 19.08.2019 Woda, Scieki Sucha pozostalosc\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa PB-23-01 z dnia 19.08.2019","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(10,0 – 10 000) mg/l"}],"search_en":"Water, Wastewater Dry residue Gravimetric method Range PB-23-01 z dnia 19.08.2019","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 10 000) mg/l"}],"search_zh":"水、污水 干残渣 重量法 范围 PB-23-01 z dnia 19.08.2019","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"干残渣"},{"_id":"6a83b47faf14b9c0e7b20c7d","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10,0 – 10 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa","reference":"PB-23-01 z dnia 19.08.2019","norm_bases":["PB-23-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa PB-23-01 z dnia 19.08.2019 Woda, Scieki Substancje rozpuszczone\nZakres (10,0 – 10 000) mg/l\nMetoda wagowa PB-23-01 z dnia 19.08.2019","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(10,0 – 10 000) mg/l"}],"search_en":"Water, Wastewater Dissolved solids Gravimetric method Range PB-23-01 z dnia 19.08.2019","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 10 000) mg/l"}],"search_zh":"水、污水 溶解性固体 重量法 范围 PB-23-01 z dnia 19.08.2019","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性固体"},{"_id":"6a83b47faf14b9c0e7b20c7e","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,20 – 100) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 100) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a83b47faf14b9c0e7b20c7f","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 4 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 4 000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 4 000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 4 000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 4 000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 4 000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83b47faf14b9c0e7b20c80","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chromu ogólnego","parameters":[{"name":"Zakres","range":"(0,100 – 15,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu ogólnego\nZakres (0,100 – 15,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000","norm_bases":["PN-EN 1233:2000"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chromu ogólnego\nZakres (0,100 – 15,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 Woda, Scieki Stezenie chromu ogolnego\nZakres (0,100 – 15,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chromium concentration","parameters_en":[{"name":"Range","range":"(0,100 – 15,0) mg/l"}],"search_en":"Water, Wastewater Total chromium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN 1233:2000","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,100 – 15,0) mg/l"}],"search_zh":"水、污水 总铬浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN 1233:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水","methodology_zh":"总铬浓度"},{"_id":"6a83b47faf14b9c0e7b20c81","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie metali:","parameters":[{"name":"cynk","range":"(0,020 – 1000) mg/l"},{"name":"kadm","range":"(0,025 – 1,00) mg/l"},{"name":"nikiel","range":"(0,100 – 15,0) mg/l"},{"name":"ołów","range":"(0,100 – 15,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali:\nZakres:\ncynk (0,020 – 1000) mg/l\nkadm (0,025 – 1,00) mg/l\nnikiel (0,100 – 15,0) mg/l\nołów (0,100 – 15,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie metali:\nZakres:\ncynk (0,020 – 1000) mg/l\nkadm (0,025 – 1,00) mg/l\nnikiel (0,100 – 15,0) mg/l\nołów (0,100 – 15,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda, Scieki Stezenie metali:\nZakres:\ncynk (0,020 – 1000) mg/l\nkadm (0,025 – 1,00) mg/l\nnikiel (0,100 – 15,0) mg/l\nolow (0,100 – 15,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water","materials"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"zinc","range":"(0,020 – 1000) mg/l"},{"name":"cadmium","range":"(0,025 – 1,00) mg/l"},{"name":"nickel","range":"(0,100 – 15,0) mg/l"},{"name":"lead","range":"(0,100 – 15,0) mg/l"}],"search_en":"Water, Wastewater Metal concentrations: Flame atomic absorption spectrometry (FAAS) zinc cadmium nickel lead PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"锌","range":"(0,020 – 1000) mg/l"},{"name":"镉","range":"(0,025 – 1,00) mg/l"},{"name":"镍","range":"(0,100 – 15,0) mg/l"},{"name":"铅","range":"(0,100 – 15,0) mg/l"}],"search_zh":"水、污水 金属浓度： 火焰原子吸收光谱法（FAAS） 锌 镉 镍 铅 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水","methodology_zh":"金属浓度："},{"_id":"6a83b47faf14b9c0e7b20c82","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(3,0 – 1 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (3,0 – 1 000) mg/l\nMetoda wagowa","reference":"PB-06-01 z dnia 19.08.2019","norm_bases":["PB-06-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (3,0 – 1 000) mg/l\nMetoda wagowa PB-06-01 z dnia 19.08.2019 Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (3,0 – 1 000) mg/l\nMetoda wagowa PB-06-01 z dnia 19.08.2019","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(3,0 – 1 000) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PB-06-01 z dnia 19.08.2019","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(3,0 – 1 000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 范围 PB-06-01 z dnia 19.08.2019","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a83b47faf14b9c0e7b20c83","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Obecność bakterii z rodzaju Salmonella w 100 g","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność bakterii z rodzaju Salmonella w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-05-01 z dnia 19.08.2019","norm_bases":["PB-05-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Obecność bakterii z rodzaju Salmonella w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-05-01 z dnia 19.08.2019 Osady sciekowe Obecnosc bakterii z rodzaju Salmonella w 100 g\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-05-01 z dnia 19.08.2019","categories":["microbiology","water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Sewage sludge Culture method with biochemical and serological confirmation PB-05-01 z dnia 19.08.2019","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Sewage sludge","search_zh":"污泥 培养法结合生化与血清学确认 PB-05-01 z dnia 19.08.2019","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"污泥"},{"_id":"6a83b47faf14b9c0e7b20c84","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 14,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 14,0\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH\nZakres 2,0 – 14,0\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH\nZakres 2,0 – 14,0\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 14,0"}],"search_en":"Sewage sludge pH Potentiometric method Range PN-EN 12176:2004","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 14,0"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a83b47faf14b9c0e7b20c85","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,1 – 98) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (0,1 – 98) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres (0,1 – 98) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc\nZakres (0,1 – 98) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,1 – 98) %"}],"search_en":"Sewage sludge Dry residue Gravimetric method Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 – 98) %"}],"search_zh":"污泥 干残渣 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣"},{"_id":"6a83b47faf14b9c0e7b20c86","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(2,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres (2,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość wody\nZakres (2,0 – 99,9) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Zawartosc wody\nZakres (2,0 – 99,9) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(2,0 – 99,9) %"}],"search_en":"Sewage sludge Water content Gravimetric method Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 99,9) %"}],"search_zh":"污泥 水分含量 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a83b47faf14b9c0e7b20c87","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu (zawartość substancji organicznych) Pozostałość po prażeniu (zawartość substancji mineralnych)","parameters":[{"name":"Zakres","range":"(5 – 95) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu (zawartość substancji organicznych) Pozostałość po prażeniu (zawartość substancji mineralnych)\nZakres (5 – 95) %\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu (zawartość substancji organicznych) Pozostałość po prażeniu (zawartość substancji mineralnych)\nZakres (5 – 95) %\nMetoda wagowa PN-EN 12879:2004 Osady sciekowe Straty przy prazeniu (zawartosc substancji organicznych) Pozostalosc po prazeniu (zawartosc substancji mineralnych)\nZakres (5 – 95) %\nMetoda wagowa PN-EN 12879:2004","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(5 – 95) %"}],"search_en":"Sewage sludge Gravimetric method Range PN-EN 12879:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5 – 95) %"}],"search_zh":"污泥 重量法 范围 PN-EN 12879:2004","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a83b47faf14b9c0e7b20c88","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,027 – 1,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,027 – 1,00) %\nMetoda miareczkowa","reference":"PB-13-01 z dnia 19.08.2019","norm_bases":["PB-13-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Stężenie azotu amonowego\nZakres (0,027 – 1,00) %\nMetoda miareczkowa PB-13-01 z dnia 19.08.2019 Osady sciekowe Stezenie azotu amonowego\nZakres (0,027 – 1,00) %\nMetoda miareczkowa PB-13-01 z dnia 19.08.2019","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,027 – 1,00) %"}],"search_en":"Sewage sludge Ammonium nitrogen concentration Titrimetric method Range PB-13-01 z dnia 19.08.2019","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,027 – 1,00) %"}],"search_zh":"污泥 氨氮浓度 滴定法 范围 PB-13-01 z dnia 19.08.2019","technique_zh":"滴定法","test_object_zh":"污泥"},{"_id":"6a83b47faf14b9c0e7b20c89","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,00 – 17,6) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (2,00 – 17,6) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres (2,00 – 17,6) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres (2,00 – 17,6) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(2,00 – 17,6) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(2,00 – 17,6) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a83b47faf14b9c0e7b20c8a","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,2 – 5,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,2 – 5,0) %\nMetoda spektrofotometryczna","reference":"PB-33-01 z dnia 01.10.2021","norm_bases":["PB-33-01 z dnia 01.10.2021"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,2 – 5,0) %\nMetoda spektrofotometryczna PB-33-01 z dnia 01.10.2021 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,2 – 5,0) %\nMetoda spektrofotometryczna PB-33-01 z dnia 01.10.2021","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,2 – 5,0) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range PB-33-01 z dnia 01.10.2021","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,2 – 5,0) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 PB-33-01 z dnia 01.10.2021","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a83b47faf14b9c0e7b20c8b","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość wapnia","parameters":[{"name":"Zakres","range":"(0,33 – 21) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość wapnia\nZakres (0,33 – 21) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-09-01 z dnia 19.08.2019","norm_bases":["PB-09-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość wapnia\nZakres (0,33 – 21) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-09-01 z dnia 19.08.2019 Osady sciekowe Zawartosc wapnia\nZakres (0,33 – 21) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-09-01 z dnia 19.08.2019","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium content","parameters_en":[{"name":"Range","range":"(0,33 – 21) %"}],"search_en":"Sewage sludge Calcium content Flame atomic absorption spectrometry (FAAS) Range PB-09-01 z dnia 19.08.2019","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,33 – 21) %"}],"search_zh":"污泥 钙含量 火焰原子吸收光谱法（FAAS） 范围 PB-09-01 z dnia 19.08.2019","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"钙含量"},{"_id":"6a83b47faf14b9c0e7b20c8c","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość magnezu","parameters":[{"name":"Zakres","range":"(0,05 – 2,2) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu\nZakres (0,05 – 2,2) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-10-01 z dnia 19.08.2019","norm_bases":["PB-10-01 z dnia 19.08.2019"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość magnezu\nZakres (0,05 – 2,2) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10-01 z dnia 19.08.2019 Osady sciekowe Zawartosc magnezu\nZakres (0,05 – 2,2) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-10-01 z dnia 19.08.2019","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium content","parameters_en":[{"name":"Range","range":"(0,05 – 2,2) %"}],"search_en":"Sewage sludge Magnesium content Flame atomic absorption spectrometry (FAAS) Range PB-10-01 z dnia 19.08.2019","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,05 – 2,2) %"}],"search_zh":"污泥 镁含量 火焰原子吸收光谱法（FAAS） 范围 PB-10-01 z dnia 19.08.2019","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"镁含量"},{"_id":"6a83b47faf14b9c0e7b20c8d","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość chromu ogólnego","parameters":[{"name":"Zakres","range":"(5,00 – 3000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość chromu ogólnego\nZakres (5,00 – 3000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 13346:2002 metoda C | PN-EN 1233:2000","norm_bases":["PN-EN 13346:2002 metoda C","PN-EN 1233:2000"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość chromu ogólnego\nZakres (5,00 – 3000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 metoda C | PN-EN 1233:2000 Osady sciekowe Zawartosc chromu ogolnego\nZakres (5,00 – 3000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 metoda C | PN-EN 1233:2000","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chromium content","parameters_en":[{"name":"Range","range":"(5,00 – 3000) mg/kg"}],"search_en":"Sewage sludge Total chromium content Flame atomic absorption spectrometry (FAAS) Range PN-EN 13346:2002 metoda C | PN-EN 1233:2000","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,00 – 3000) mg/kg"}],"search_zh":"污泥 总铬含量 火焰原子吸收光谱法（FAAS） 范围 PN-EN 13346:2002 metoda C | PN-EN 1233:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"总铬含量"},{"_id":"6a83b47faf14b9c0e7b20c8e","lab_id":"69ad52a3de79e566650fb440","country":"PL","accr_number":"AB 842","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali:","parameters":[{"name":"cynk","range":"(10,0 – 7000) mg/kg"},{"name":"kadm","range":"(3,00 – 250) mg/kg"},{"name":"miedź","range":"(5,00 – 2500) mg/kg"},{"name":"nikiel","range":"(5,00 – 1000) mg/kg"},{"name":"ołów","range":"(5,00 – 2000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali:\nZakres:\ncynk (10,0 – 7000) mg/kg\nkadm (3,00 – 250) mg/kg\nmiedź (5,00 – 2500) mg/kg\nnikiel (5,00 – 1000) mg/kg\nołów (5,00 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 13346:2002 metoda C | PN-ISO 8288:2002 metoda A","norm_bases":["PN-EN 13346:2002 metoda C","PN-ISO 8288:2002 metoda A"],"lab_section":"Laboratorium; Zawiszów 5, 58-100 Świdnica","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali:\nZakres:\ncynk (10,0 – 7000) mg/kg\nkadm (3,00 – 250) mg/kg\nmiedź (5,00 – 2500) mg/kg\nnikiel (5,00 – 1000) mg/kg\nołów (5,00 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 metoda C | PN-ISO 8288:2002 metoda A Osady sciekowe Zawartosc metali:\nZakres:\ncynk (10,0 – 7000) mg/kg\nkadm (3,00 – 250) mg/kg\nmiedz (5,00 – 2500) mg/kg\nnikiel (5,00 – 1000) mg/kg\nolow (5,00 – 2000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 metoda C | PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content:","parameters_en":[{"name":"zinc","range":"(10,0 – 7000) mg/kg"},{"name":"cadmium","range":"(3,00 – 250) mg/kg"},{"name":"copper","range":"(5,00 – 2500) mg/kg"},{"name":"nickel","range":"(5,00 – 1000) mg/kg"},{"name":"lead","range":"(5,00 – 2000) mg/kg"}],"search_en":"Sewage sludge Metal content: Flame atomic absorption spectrometry (FAAS) zinc cadmium copper nickel lead PN-EN 13346:2002 metoda C | PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"锌","range":"(10,0 – 7000) mg/kg"},{"name":"镉","range":"(3,00 – 250) mg/kg"},{"name":"铜","range":"(5,00 – 2500) mg/kg"},{"name":"镍","range":"(5,00 – 1000) mg/kg"},{"name":"铅","range":"(5,00 – 2000) mg/kg"}],"search_zh":"污泥 金属含量： 火焰原子吸收光谱法（FAAS） 锌 镉 铜 镍 铅 PN-EN 13346:2002 metoda C | PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"金属含量："}],"has_pdf":true}