{"lab":{"_id":"69ad52a3de79e566650fb43e","accr_number":"AB 841","country":"PL","accr_body":"PCA","address":"ul. Szkolna 15, 47-225 Kędzierzyn-Koźle","categories":["environment"],"city":"Kędzierzyn-Koźle","imported_at":"2026-03-08T10:42:43.265Z","methods_count":14,"name":"LABORATORIUM BADAWCZE BLACHOWNIA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_841.pdf"],"scope_summary":"","search_text":"laboratorium badawcze blachownia sp. z o.o. ul. szkolna 15, 47-225 kędzierzyn-koźle environment metrology materials other","status":"active","updated_at":"2026-03-08T14:51:43.661Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-28T00:38:17.710Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20841,podmiot.html","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling of working environment (harmful factors - air)"},{"codes":"G/33; G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, mikroklimat, hałas i drgania), środowisko ogólne (czynniki fizyczne – hałas)","en":"Test concerning environmental engineering (enviromental and climatic) – workplace (harmful and nuisance factors – lighting, microclimate, noise, vibration), general environment (physical factors – noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling of working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling of working environment (harmful factors - air)"}],"issue":{"no":"21","date":"25.08.2026"},"parse_date":"2026-08-28T00:38:17.710Z","parse_source":"agent-claude-code","map_coord":[50.355112,18.266596],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":13,"construction":2,"materials":1},"category_scores":{"environment":10.56,"construction":0.25,"materials":0.06},"has_zh":true,"lab_locations":[{"name":"LABORATORIUM BADAWCZE – BLACHOWNIA Sp. z o.o.","address":"Aleja Jana Pawła II 41A 47-232 Kędzierzyn-Koźle","city":"Kędzierzyn-Koźle","postal":"47-232"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/27/a54dfae7e8ef2d6166f1d9d1086cb85b/AB%20841.pdf"},"methods":[{"_id":"6a90d8793e9c9f260ef7e6ab","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5000) Ix"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) Ix\nMetoda pomiarowa bezpośrednia","reference":"PN 83/E-04040.03 | PB/HP-02 wyd. 7 z dn. 06.05.2025 r.","norm_bases":["PN 83/E-04040.03","PB/HP-02 wyd. 7 z dn. 06.05.2025 r."],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5000) Ix\nMetoda pomiarowa bezpośrednia PN 83/E-04040.03 | PB/HP-02 wyd. 7 z dn. 06.05.2025 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5000) Ix\nMetoda pomiarowa bezposrednia PN 83/E-04040.03 | PB/HP-02 wyd. 7 z dn. 06.05.2025 r.","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6ac","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN 83/E-04040.03 | PB/HP-02 wyd. 7 z dn. 06.05.2025 r.","norm_bases":["PN 83/E-04040.03","PB/HP-02 wyd. 7 z dn. 06.05.2025 r."],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN 83/E-04040.03 | PB/HP-02 wyd. 7 z dn. 06.05.2025 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN 83/E-04040.03 | PB/HP-02 wyd. 7 z dn. 06.05.2025 r.","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6ad","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne w tym:"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym:"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym:\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym:\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne w tym:\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym:\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6ae","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6af","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,26-16,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,26-16,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,26-16,6) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwie-rzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nZakres (0,26-16,6) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b0","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,14 – 11,1) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,14 – 11,1) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwie-rzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,14 – 11,1) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwie-rzecego i roslinnego z wyjatkiem pylow drewna oraz maki\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,14 – 11,1) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b1","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,32 – 232) mg/m3"},{"name":"Zakres","range":"(2-200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2-200) ppm\nMetoda elektrochemiczna","reference":"PB/HP-10 wyd. 6 z dn. 12.04.2023 r.","norm_bases":["PB/HP-10 wyd. 6 z dn. 12.04.2023 r."],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2-200) ppm\nMetoda elektrochemiczna PB/HP-10 wyd. 6 z dn. 12.04.2023 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2-200) ppm\nMetoda elektrochemiczna PB/HP-10 wyd. 6 z dn. 12.04.2023 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b2","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB/HP-10 wyd. 6 z dn. 12.04.2023 r.","norm_bases":["PB/HP-10 wyd. 6 z dn. 12.04.2023 r."],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB/HP-10 wyd. 6 z dn. 12.04.2023 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB/HP-10 wyd. 6 z dn. 12.04.2023 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b3","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 135) dB"},{"name":"Szczytowy poziom dźwięku C","range":"(40 –138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 135) dB\nSzczytowy poziom dźwięku C (40 –138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - pkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - pkt 10 i 11"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 135) dB\nSzczytowy poziom dźwięku C (40 –138) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - pkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 – 135) dB\nSzczytowy poziom dzwieku C (40 –138) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - pkt 10 i 11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b4","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy\n(z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - pkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - pkt 10 i 11"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy\n(z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 - pkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy\n(z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 - pkt 10 i 11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b5","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,5 – 100) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"(z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,5 – 100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,5 – 100) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,5 – 100) m/s2\nEkspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)\n(z obliczen)\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b6","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,05 – 30) m/s²"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"(z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,05 – 30) m/s²\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,05 – 30) m/s²\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,05 – 30) m/s²\nEkspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\nEkspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\n(z obliczen)\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b7","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt E.II.1 i F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt E.II.1 i F"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt E.II.1 i F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wylaczeniem pkt E.II.1 i F","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a90d8793e9c9f260ef7e6b8","lab_id":"69ad52a3de79e566650fb43e","country":"PL","accr_number":"AB 841","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt E.II.1 i F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt E.II.1 i F"],"lab_section":"Laboratorium Badawcze – Blachownia Sp. z o.o.; Aleja Jana Pawła II 41A, 47-232, 47-232 Kędzierzyn-Koźle","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem pkt E.II.1 i F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wylaczeniem pkt E.II.1 i F","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}