{"lab":{"_id":"69ad52a3de79e566650fb434","accr_number":"AB 833","country":"PL","accr_body":"PCA","address":"ul. Olimpijska 6, 45-681 Opole","categories":["environment","water"],"city":"Opole","imported_at":"2026-03-08T10:42:43.265Z","methods_count":175,"name":"ZAKŁAD WYKONYWANIA POMIARÓW EMITOR Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_833.pdf"],"scope_summary":"","search_text":"zakład wykonywania pomiarów emitor sp. z o.o. ul. olimpijska 6, 45-681 opole water other pharma electronics food microbiology environment automotive metrology materials construction","status":"active","updated_at":"2026-03-08T14:51:43.296Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:19:01.931Z","location":{"type":"Point","coordinates":[17.9213,50.6751]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20833,podmiot.html","fields_of_testing":[{"codes":"A/13","pl":"Badania akustyczne i drgań - maszyny i urządzenia","en":"Acoustic and vibration tests of machines and devices;"},{"codes":"C/28/P","pl":"Badania chemiczne i pobieranie próbek wody","en":"Chemical tests and sampling of water,"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage,"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling - working environment (harmful faktory – air),"},{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases,"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, hałas w pomieszczeniach, drgania, oświetlenie, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, facilities noise, vibration, lighting, microclimate),"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise),"},{"codes":"G/35","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – pomieszczenia (warunki środowiskowe – wentylacja)","en":"Tests concerning environmental engineering (environmental and climatic) - rooms (environmental conditions - ventilation),"},{"codes":"M/39","pl":"Badania inne urządzeń ochrony powietrza","en":"Other testes air protection equipment,"},{"codes":"M/58","pl":"Badania inne QAL2 i AST automatycznych systemów monitoringu (AMS)","en":"Other tests - QAL2 i AST of automated measuring systems (AMS),"}],"issue":{"no":"25","date":"30.07.2026"},"parse_date":"2026-08-18T01:19:01.931Z","parse_source":"agent-claude-code","map_coord":[50.623048,17.996223],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD WYKONYWANIA POMIARÓW EMITOR Sp. z o.o.","address":"ul. Olimpijska 6","city":null,"postal":null},{"name":"Laboratorium Badania Wody i Ścieków","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"},{"name":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"},{"name":"Laboratorium Higieny Pracy","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"},{"name":"Laboratorium Badania Powietrza","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/7b25be8baa62ab3fd15300301ea92f31/AB%20833.pdf","has_en":true,"category_counts":{"environment":77,"other":58,"water":38,"materials":3,"construction":2,"petro":2,"microbiology":2,"metrology":2},"category_scores":{"environment":32.22,"other":18.28,"water":7.85,"materials":0.05,"construction":0.02,"petro":0.02,"microbiology":0.02,"metrology":0.02},"has_zh":true,"lab_locations_zh":[{"name":"ZAKŁAD WYKONYWANIA POMIARÓW EMITOR Sp. z o.o.","address":"ul. Olimpijska 6","city":null,"postal":null},{"name":"水与废水检测实验室","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"},{"name":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"},{"name":"Laboratorium Higieny Pracy","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"},{"name":"Laboratorium Badania Powietrza","address":"ul. Olimpijska 6, 45-681 Opole","city":"Opole","postal":"45-681"}]},"methods":[{"_id":"6a83b305af14b9c0e7b20b2d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Water and Wastewater Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"水、废水 pH 值 电位法 水与废水检测实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b2e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów (VI)","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów (VI)\nZakres (10 - 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów (VI)\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow (VI)\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sulphate (VI) concentration","parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"}],"search_en":"Water, wastewater Sulphate (VI) concentration Gravimetric method Water and Wastewater Testing Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"}],"search_zh":"水、废水 硫酸盐(VI)浓度 重量法 水与废水检测实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"硫酸盐(VI)浓度"},{"_id":"6a83b305af14b9c0e7b20b2f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,076 - 2,45) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,076 - 2,45) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 +Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 4 +Ap1:2010 + Ap2:2010"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,076 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010 + Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,076 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010 + Ap2:2010","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,076 - 2,45) mg/l"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-EN ISO 6878:2006 p. 4 +Ap1:2010 + Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,076 - 2,45) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 水与废水检测实验室 范围 PN-EN ISO 6878:2006 p. 4 +Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"正磷酸盐浓度"},{"_id":"6a83b305af14b9c0e7b20b30","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,025 - 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,025 - 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 8 +Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 8 +Ap1:2010 + Ap2:2010"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,025 - 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 +Ap1:2010 + Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,025 - 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 +Ap1:2010 + Ap2:2010","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,025 - 20) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-EN ISO 6878:2006 p. 8 +Ap1:2010 + Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,025 - 20) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 水与废水检测实验室 范围 PN-EN ISO 6878:2006 p. 8 +Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b31","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 - 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 - 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 - 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 - 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 - 1000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Water and Wastewater Testing Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 水与废水检测实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b32","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 - 2480) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 - 2480) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10 - 2480) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 - 2480) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 - 2480) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Water and Wastewater Testing Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 - 2480) μS/cm"}],"search_zh":"水、废水 电导率 电导法 水与废水检测实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b33","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT - Cr","parameters":[{"name":"Zakres","range":"(10 - 30) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT - Cr\nZakres (10 - 30) mg/l O2\nMetoda miareczkowa","reference":"PN-74/C-04578-03","norm_bases":["PN-74/C-04578-03"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT - Cr\nZakres (10 - 30) mg/l O2\nMetoda miareczkowa PN-74/C-04578-03 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT - Cr\nZakres (10 - 30) mg/l O2\nMetoda miareczkowa PN-74/C-04578-03","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Chemical oxygen demand COD - Cr","parameters_en":[{"name":"Range","range":"(10 - 30) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand COD - Cr Titrimetric method Water and Wastewater Testing Laboratory Range PN-74/C-04578-03","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 - 30) mg/l O2"}],"search_zh":"水、废水 滴定法 水与废水检测实验室 范围 PN-74/C-04578-03","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b34","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT - Cr","parameters":[{"name":"Zakres","range":"(30 - 4000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT - Cr\nZakres (30 - 4000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT - Cr\nZakres (30 - 4000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT - Cr\nZakres (30 - 4000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Chemical oxygen demand COD - Cr","parameters_en":[{"name":"Range","range":"(30 - 4000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand COD - Cr Titrimetric method Water and Wastewater Testing Laboratory Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(30 - 4000) mg/l O2"}],"search_zh":"水、废水 滴定法 水与废水检测实验室 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b35","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(5 - 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (5 - 150) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (5 - 150) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (5 - 150) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(5 - 150) mg/l"}],"search_en":"Water, wastewater Chemical oxygen demand (COD-Cr) Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(5 - 150) mg/l"}],"search_zh":"水、废水 化学需氧量（ChZT-Cr / CODCr） 分光光度法 水与废水检测实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b36","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 - 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 - 3000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 - 3000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 - 3000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Water and Wastewater Testing Laboratory Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 3000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 水与废水检测实验室 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b37","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0125 - 6,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0125 - 6,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0125 - 6,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0125 - 6,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0125 - 6,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0125 - 6,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 水与废水检测实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b38","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,040 - 25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,040 - 25) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,040 - 25) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,040 - 25) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,040 - 25) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 - 25) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 水与废水检测实验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b39","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,40 - 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,40 - 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,40 - 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,40 - 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,40 - 1000) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Water and Wastewater Testing Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,40 - 1000) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 水与废水检测实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b3a","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3 - 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815:2019","norm_bases":["PN-EN ISO 5815:2019"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815:2019 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815:2019","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3 - 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Water and Wastewater Testing Laboratory Range PN-EN ISO 5815:2019","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 - 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 水与废水检测实验室 范围 PN-EN ISO 5815:2019","technique_zh":"电化学法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b305af14b9c0e7b20b3b","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 - 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 - 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Water and Wastewater Testing Laboratory Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 - 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 水与废水检测实验室 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b305af14b9c0e7b20b3c","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,40 - 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,40 - 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,40 - 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,40 - 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,40 - 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Water and Wastewater Testing Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,40 - 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 水与废水检测实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b3d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,050 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,050 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 - 1,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 - 1,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 水与废水检测实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b3e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,03 - 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,03 - 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie żelaza ogólnego\nZakres (0,03 - 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Woda, scieki Stezenie zelaza ogolnego\nZakres (0,03 - 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,03 - 20) mg/l"}],"search_en":"Water, wastewater Total iron concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-ISO 6332:2001","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,03 - 20) mg/l"}],"search_zh":"水、废水 总铁浓度 分光光度法 水与废水检测实验室 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b3f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Azot ogólny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Azot ogólny (z obliczeń)","reference":"PN-73/C-04576-14","norm_bases":["PN-73/C-04576-14"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Azot ogólny (z obliczeń) PN-73/C-04576-14 Woda, scieki Azot ogolny (z obliczen) PN-73/C-04576-14","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total nitrogen (calculated)","search_en":"Water, wastewater Total nitrogen (calculated) Water and Wastewater Testing Laboratory PN-73/C-04576-14","test_object_en":"Water, wastewater","search_zh":"水、废水 总氮（由计算得出） 水与废水检测实验室 PN-73/C-04576-14","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"总氮（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20b40","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 - 20) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 - 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 - 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 - 20) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 - 20) mg/l"}],"search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Water and Wastewater Testing Laboratory Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 20) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 水与废水检测实验室 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"矿物油指数"},{"_id":"6a83b305af14b9c0e7b20b41","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (10 - 5000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Substancje rozpuszczone\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Substancje rozpuszczone\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"}],"search_en":"Water, wastewater Dissolved solids Gravimetric method Water and Wastewater Testing Laboratory Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"}],"search_zh":"水、废水 溶解性固体 重量法 水与废水检测实验室 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"溶解性固体"},{"_id":"6a83b305af14b9c0e7b20b42","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10 - 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (10 - 5000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Sucha pozostalosc\nZakres (10 - 5000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(10 - 5000) mg/l"}],"search_en":"Water, wastewater Dry residue Gravimetric method Water and Wastewater Testing Laboratory Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 - 5000) mg/l"}],"search_zh":"水、废水 干残渣 重量法 水与废水检测实验室 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室","methodology_zh":"干残渣"},{"_id":"6a83b305af14b9c0e7b20b43","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Substancje ekstrahujące się eterem naftowym (ekstrakt eterowy)","parameters":[{"name":"Zakres","range":"(2,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym (ekstrakt eterowy)\nZakres (2,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573-01","norm_bases":["PN-86/C-04573-01"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Substancje ekstrahujące się eterem naftowym (ekstrakt eterowy)\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-86/C-04573-01 Woda, scieki Substancje ekstrahujace sie eterem naftowym (ekstrakt eterowy)\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-86/C-04573-01","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Petroleum ether extractable substances (ether extract)","parameters_en":[{"name":"Range","range":"(2,0 - 1000) mg/l"}],"search_en":"Water, wastewater Petroleum ether extractable substances (ether extract) Gravimetric method Water and Wastewater Testing Laboratory Range PN-86/C-04573-01","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(2,0 - 1000) mg/l"}],"search_zh":"水、废水 重量法 水与废水检测实验室 范围 PN-86/C-04573-01","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b44","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie indeksu fenolowego","parameters":[{"name":"Zakres","range":"(0,002 - 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie indeksu fenolowego\nZakres (0,002 - 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie indeksu fenolowego\nZakres (0,002 - 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, scieki Stezenie indeksu fenolowego\nZakres (0,002 - 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Phenol index concentration","parameters_en":[{"name":"Range","range":"(0,002 - 5,0) mg/l"}],"search_en":"Water, wastewater Phenol index concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,002 - 5,0) mg/l"}],"search_zh":"水、废水 分光光度法 水与废水检测实验室 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b45","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 - 50,0) 0C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 - 50,0) 0C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 - 50,0) 0C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 - 50,0) 0C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 - 50,0) 0C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Water and Wastewater Testing Laboratory Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 - 50,0) 0C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 水与废水检测实验室 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b46","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda","methodology":"Tlen rozpuszczony","parameters":[{"name":"Zakres","range":"(0,6 - 16) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Tlen rozpuszczony\nZakres (0,6 - 16) mg/l O2\nMetoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Tlen rozpuszczony\nZakres (0,6 - 16) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997 Woda Tlen rozpuszczony\nZakres (0,6 - 16) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Dissolved oxygen","parameters_en":[{"name":"Range","range":"(0,6 - 16) mg/l O2"}],"search_en":"Water Dissolved oxygen Titrimetric method Water and Wastewater Testing Laboratory Range PN-EN 25813:1997","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,6 - 16) mg/l O2"}],"search_zh":"水 溶解氧 滴定法 水与废水检测实验室 范围 PN-EN 25813:1997","technique_zh":"滴定法","test_object_zh":"水","lab_section_zh":"水与废水检测实验室","methodology_zh":"溶解氧"},{"_id":"6a83b305af14b9c0e7b20b47","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 - 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C","reference":"PN-ISO 5667-4:2017 | PN-77/C-04584","norm_bases":["PN-ISO 5667-4:2017","PN-77/C-04584"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-4:2017 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-4:2017 | PN-77/C-04584","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 - 50,0) 0C"}],"search_en":"Water Sampling for chemical and physical testing Temperature Water and Wastewater Testing Laboratory Range PN-ISO 5667-4:2017 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 - 50,0) 0C"}],"search_zh":"水 化学和物理检测采样 温度 水与废水检测实验室 范围 PN-ISO 5667-4:2017 | PN-77/C-04584","test_object_zh":"水","lab_section_zh":"水与废水检测实验室","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a83b305af14b9c0e7b20b48","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 - 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C","reference":"PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.3, 7.5, 7.6 oraz 8.2 | PN-77/C-04584","norm_bases":["PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.3, 7.5, 7.6 oraz 8.2","PN-77/C-04584"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.3, 7.5, 7.6 oraz 8.2 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-6:2016-12 z wylaczeniem punktow 7.3, 7.5, 7.6 oraz 8.2 | PN-77/C-04584","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 - 50,0) 0C"}],"search_en":"Water Sampling for chemical and physical testing Temperature Water and Wastewater Testing Laboratory Range PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.3, 7.5, 7.6 oraz 8.2 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 - 50,0) 0C"}],"search_zh":"水 化学和物理检测采样 温度 水与废水检测实验室 范围 PN-ISO 5667-6:2016-12 z wyłączeniem punktów 7.3, 7.5, 7.6 oraz 8.2 | PN-77/C-04584","test_object_zh":"水","lab_section_zh":"水与废水检测实验室","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a83b305af14b9c0e7b20b49","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 - 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2, 6.3","PN-77/C-04584"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-11:2017-10 z wylaczeniem pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 - 50,0) 0C"}],"search_en":"Water Sampling for chemical and physical testing Temperature Water and Wastewater Testing Laboratory Range PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 - 50,0) 0C"}],"search_zh":"水 化学和物理检测采样 温度 水与废水检测实验室 范围 PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","test_object_zh":"水","lab_section_zh":"水与废水检测实验室","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a83b305af14b9c0e7b20b4a","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-10:2021-11 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-10:2021-11","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Water and Wastewater Testing Laboratory PN-ISO 5667-10:2021-11","test_object_en":"Rainwater, snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水、融雪水 化学与物理检测用样品采集 水与废水检测实验室 PN-ISO 5667-10:2021-11","test_object_zh":"雨水、融雪水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b4b","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 - 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2,0 - 3000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2,0 - 3000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 - 3000) mg/l"}],"search_en":"Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Water and Wastewater Testing Laboratory Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater, snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 3000) mg/l"}],"search_zh":"雨水、融雪水 总悬浮物 重量法 水与废水检测实验室 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水、融雪水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b4c","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 - 20) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 - 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,10 - 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Wody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,10 - 20) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 - 20) mg/l"}],"search_en":"Rainwater, snowmelt water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Water and Wastewater Testing Laboratory Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Rainwater, snowmelt water","parameters_zh":[{"name":"范围","range":"(0,10 - 20) mg/l"}],"search_zh":"雨水、融雪水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 水与废水检测实验室 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"雨水、融雪水","lab_section_zh":"水与废水检测实验室","methodology_zh":"矿物油指数"},{"_id":"6a83b305af14b9c0e7b20b4d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,0 - 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,0 - 50,0) 0C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,0 - 50,0) 0C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Water and Wastewater Testing Laboratory Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0 - 50,0) 0C"}],"search_zh":"生活饮用水 化学和物理检测采样 温度 水与废水检测实验室 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","lab_section_zh":"水与废水检测实验室","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a83b305af14b9c0e7b20b4e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, woda do spozycia przez ludzi, scieki Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water, water intended for human consumption, wastewater Sampling for microbiological testing Water and Wastewater Testing Laboratory PN-EN ISO 19458:2007","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水、污水 微生物检测用样品采集 水与废水检测实验室 PN-EN ISO 19458:2007","test_object_zh":"水、生活饮用水、污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b4f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek osadów do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek osadów do badań fizycznych i chemicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek osadów do badań fizycznych i chemicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek osadow do badan fizycznych i chemicznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sludge sampling for physical and chemical testing","search_en":"Sewage sludge Sludge sampling for physical and chemical testing Water and Wastewater Testing Laboratory PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","search_zh":"污泥 水与废水检测实验室 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b50","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek osadów ściekowych do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek osadów ściekowych do badań mikrobiologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek osadów ściekowych do badań mikrobiologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek osadow sciekowych do badan mikrobiologicznych PN-EN ISO 5667-13:2011","categories":["water","microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sewage sludge sampling for microbiological testing","search_en":"Sewage sludge Sewage sludge sampling for microbiological testing Water and Wastewater Testing Laboratory PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","search_zh":"污泥 水与废水检测实验室 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b51","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 13,0\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH\nZakres 2,0 - 13,0\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 13,0"}],"search_en":"Sewage sludge pH Potentiometric method Water and Wastewater Testing Laboratory Range PN-EN 12176:2004","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 13,0"}],"search_zh":"污泥 pH 值 电位法 水与废水检测实验室 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污泥","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b52","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w KCl, pH – w CaCl2, pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w KCl, pH – w CaCl2, pH – w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN 10390:2022-09","norm_bases":["PN-EN 10390:2022-09"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w KCl, pH – w CaCl2, pH – w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09 Osady sciekowe pH – w KCl, pH – w CaCl2, pH – w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"pH – in KCl, pH – in CaCl2, pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"Sewage sludge pH – in KCl, pH – in CaCl2, pH – in H2O Potentiometric method Water and Wastewater Testing Laboratory Range PN-EN 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"污泥 电位法 水与废水检测实验室 范围 PN-EN 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b53","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek gleby do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek gleby do badań fizycznych i chemicznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007 | ISO 18400-205:2018","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007","ISO 18400-205:2018"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek gleby do badań fizycznych i chemicznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | ISO 18400-205:2018 Gleba Pobieranie probek gleby do badan fizycznych i chemicznych PN-R-04031:1997 | PN-ISO 10381-4:2007 | ISO 18400-205:2018","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Soil sampling for physical and chemical testing","search_en":"Soil Soil sampling for physical and chemical testing Water and Wastewater Testing Laboratory PN-R-04031:1997 | PN-ISO 10381-4:2007 | ISO 18400-205:2018","test_object_en":"Soil","search_zh":"土壤 水与废水检测实验室 PN-R-04031:1997 | PN-ISO 10381-4:2007 | ISO 18400-205:2018","test_object_zh":"土壤","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b54","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gleba","methodology":"pH – w KCl, pH – w CaCl2, pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w KCl, pH – w CaCl2, pH – w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN 10390:2022-09","norm_bases":["PN-EN 10390:2022-09"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH – w KCl, pH – w CaCl2, pH – w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09 Gleba pH – w KCl, pH – w CaCl2, pH – w H2O\nZakres 2,0 - 12,0\nMetoda potencjometryczna PN-EN 10390:2022-09","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"pH – in KCl, pH – in CaCl2, pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 - 12,0"}],"search_en":"Soil pH – in KCl, pH – in CaCl2, pH – in H2O Potentiometric method Water and Wastewater Testing Laboratory Range PN-EN 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 - 12,0"}],"search_zh":"土壤 电位法 水与废水检测实验室 范围 PN-EN 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤","lab_section_zh":"水与废水检测实验室"},{"_id":"6a83b305af14b9c0e7b20b55","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,004 - 2,5) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość formaldehydu\nZakres (0,004 - 2,5) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045-04","norm_bases":["PN-76/Z-04045-04"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki powietrza pobrane do roztworu pochłaniającego Zawartość formaldehydu\nZakres (0,004 - 2,5) mg w próbce\nMetoda spektrofotometryczna PN-76/Z-04045-04 Srodowisko ogolne - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc formaldehydu\nZakres (0,004 - 2,5) mg w probce\nMetoda spektrofotometryczna PN-76/Z-04045-04","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Formaldehyde content","parameters_en":[{"name":"Range","range":"(0,004 - 2,5) mg w próbce"}],"search_en":"General environment - air samples collected into an absorbing solution Formaldehyde content Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-76/Z-04045-04","technique_en":"Spectrophotometric method","test_object_en":"General environment - air samples collected into an absorbing solution","parameters_zh":[{"name":"范围","range":"(0,004 - 2,5) mg w próbce"}],"search_zh":"甲醛含量 分光光度法 水与废水检测实验室 范围 PN-76/Z-04045-04","technique_zh":"分光光度法","lab_section_zh":"水与废水检测实验室","methodology_zh":"甲醛含量"},{"_id":"6a83b305af14b9c0e7b20b56","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,03 - 0,3) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość amoniaku\nZakres (0,03 - 0,3) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki powietrza pobrane do roztworu pochłaniającego Zawartość amoniaku\nZakres (0,03 - 0,3) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko ogolne - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc amoniaku\nZakres (0,03 - 0,3) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Ammonia content","parameters_en":[{"name":"Range","range":"(0,03 - 0,3) mg w próbce"}],"search_en":"General environment - air samples collected into an absorbing solution Ammonia content Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"General environment - air samples collected into an absorbing solution","parameters_zh":[{"name":"范围","range":"(0,03 - 0,3) mg w próbce"}],"search_zh":"氨含量 分光光度法 水与废水检测实验室 范围 PN-71/Z-04041","technique_zh":"分光光度法","lab_section_zh":"水与废水检测实验室","methodology_zh":"氨含量"},{"_id":"6a83b305af14b9c0e7b20b57","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,08 - 30,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość chlorowodoru\nZakres (0,08 - 30,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki powietrza pobrane do roztworu pochłaniającego Zawartość chlorowodoru\nZakres (0,08 - 30,0) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Srodowisko ogolne - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc chlorowodoru\nZakres (0,08 - 30,0) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Hydrogen chloride content","parameters_en":[{"name":"Range","range":"(0,08 - 30,0) mg w próbce"}],"search_en":"General environment - air samples collected into an absorbing solution Hydrogen chloride content Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"General environment - air samples collected into an absorbing solution","parameters_zh":[{"name":"范围","range":"(0,08 - 30,0) mg w próbce"}],"search_zh":"氯化氢含量 分光光度法 水与废水检测实验室 范围 PN-EN 1911:2011","technique_zh":"分光光度法","lab_section_zh":"水与废水检测实验室","methodology_zh":"氯化氢含量"},{"_id":"6a83b305af14b9c0e7b20b58","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,03 - 0,3) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość amoniaku\nZakres (0,03 - 0,3) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego Zawartość amoniaku\nZakres (0,03 - 0,3) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc amoniaku\nZakres (0,03 - 0,3) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Ammonia content","parameters_en":[{"name":"Range","range":"(0,03 - 0,3) mg w próbce"}],"search_en":"Workplace environment - air samples collected into absorbing solution Ammonia content Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,03 - 0,3) mg w próbce"}],"search_zh":"工作环境 － 采集于吸收液中的空气样品 氨含量 分光光度法 水与废水检测实验室 范围 PN-71/Z-04041","technique_zh":"分光光度法","lab_section_zh":"水与废水检测实验室","methodology_zh":"氨含量","test_object_zh":"工作环境 － 采集于吸收液中的空气样品"},{"_id":"6a83b305af14b9c0e7b20b59","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku","parameters":[{"name":"Zakres","range":"(24 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku\nZakres (24 - 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants Equivalent sound level Direct measurement method Range Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 直接测量法 范围 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83b305af14b9c0e7b20b5a","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83b305af14b9c0e7b20b5b","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministerstwa Srodowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wylaczeniem punktu H","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"}],"search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment - noise from roads, railway lines, tram lines","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a83b305af14b9c0e7b20b5c","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministerstwa Srodowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wylaczeniem punktu H","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H","test_object_en":"General environment - noise from roads, railway lines, tram lines","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministerstwa Środowiska z dn.16.06.2011 r. (Dz. U. Nr 140 poz. 824 i Nr 288, poz. 1697) - z wyłączeniem punktu H","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a83b305af14b9c0e7b20b5d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-87/B-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83b305af14b9c0e7b20b5e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83b305af14b9c0e7b20b5f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego, przenikający do pomieszczeń","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego, przenikający do pomieszczeń Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego, przenikajacy do pomieszczen Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (24 - 137) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"}],"search_en":"Rooms in residential, collective residence and public buildings – noise from technical service equipment penetrating into rooms A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public buildings – noise from technical service equipment penetrating into rooms","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"}],"search_zh":"A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","technique_zh":"直接测量法"},{"_id":"6a83b305af14b9c0e7b20b60","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego, przenikający do pomieszczeń","methodology":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy., Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy., Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy (z obliczeń)","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/A1:2010","PN-EN ISO 10052:2021-12"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego, przenikający do pomieszczeń Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy., Wzorcowy równoważny poziom dźwięku A, C dla cyklu pracy (z obliczeń) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego, przenikajacy do pomieszczen Wzorcowy rownowazny poziom dzwieku A, C dla cyklu pracy., Wzorcowy rownowazny poziom dzwieku A, C dla cyklu pracy (z obliczen) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","categories":["environment","metrology"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reference equivalent A, C sound level for the operating cycle., Reference equivalent A, C sound level for the operating cycle (calculated)","search_en":"Rooms in residential, collective residence and public buildings – noise from technical service equipment penetrating into rooms Reference equivalent A, C sound level for the operating cycle., Reference equivalent A, C sound level for the operating cycle (calculated) PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 | PN-EN ISO 10052:2021-12","test_object_en":"Rooms in residential, collective residence and public buildings – noise from technical service equipment penetrating into rooms"},{"_id":"6a83b305af14b9c0e7b20b61","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom ciśnienia akustycznego","parameters":[{"name":"skorygowany charakterystyką"},{"name":"częstotliwościową A"},{"name":"Zakres","range":"(24 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (24 - 137) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4 Maszyny i urzadzenia – halas Poziom cisnienia akustycznego\nZakres:\nskorygowany charakterystyka\nczestotliwosciowa A\nZakres (24 - 137) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wylaczeniem punktu 8.4","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound pressure level","parameters_en":[{"name":"weighted with the characteristic"},{"name":"frequency weighting A"},{"name":"Range","range":"(24 - 137) dB"}],"search_en":"Machinery and equipment – noise Sound pressure level Direct measurement method weighted with the characteristic frequency weighting A Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","parameters_zh":[{"name":"按特性计权"},{"name":"A 计权"},{"name":"范围","range":"(24 - 137) dB"}],"search_zh":"机器与设备 – 噪声 声压级 直接测量法 按特性计权 A 计权 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声压级"},{"_id":"6a83b305af14b9c0e7b20b62","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4"],"lab_section":"Laboratorium Higieny Pracy - Pracownia Dokumentacji i Badań Środowisk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wylaczeniem punktu 8.4","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4","test_object_en":"Machinery and equipment – noise","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 z wyłączeniem punktu 8.4","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a83b305af14b9c0e7b20b63","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 137) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(68 - 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nSzczytowy poziom dźwięku C\nZakres (68 - 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","norm_bases":["PN-N-01307: 1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 137) dB\nSzczytowy poziom dźwięku C\nZakres (68 - 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (24 - 137) dB\nSzczytowy poziom dzwieku C\nZakres (68 - 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkty 10 i 11","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24 - 137) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(68 - 140) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 - 137) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(68 - 140) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b305af14b9c0e7b20b64","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy,"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy,\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","norm_bases":["PN-N-01307: 1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy,\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy,\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej Strategie 2 i 3 – punkty 10 i 11","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"8-hour daily working time,"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: 8-hour daily working time, the average weekly working time (calculated) PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8-godzinnego dobowego wymiaru czasu pracy,"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 平均每周工作时间（计算值） PN-N-01307: 1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej Strategię 2 i 3 – punkty 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b305af14b9c0e7b20b65","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,08 - 125) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia; Metoda próbkowania","techniques":["Metoda pomiarowa bezpośrednia","Metoda próbkowania"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,08 - 125) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,08 - 125) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,08 - 125) m/s2\nMetoda pomiarowa bezposrednia; Metoda probkowania PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,08 - 125) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method; Sampling method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_en":"Direct measurement method; Sampling method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,08 - 125) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法；采样法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","technique_zh":"直接测量法；采样法"},{"_id":"6a83b305af14b9c0e7b20b66","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz);, Ekspozycja trwająca 30 min. i krócej wyrażona w postaci suma wektorowa skutecznych, ważonych częstotliwościowo przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz);, Ekspozycja trwająca 30 min. i krócej wyrażona w postaci suma wektorowa skutecznych, ważonych częstotliwościowo przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna wyrażona w postaci równoważnej energetycznie dla 8 godzin działania sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz);, Ekspozycja trwająca 30 min. i krócej wyrażona w postaci suma wektorowa skutecznych, ważonych częstotliwościowo przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna wyrazona w postaci rownowaznej energetycznie dla 8 godzin dzialania sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz);, Ekspozycja trwajaca 30 min. i krocej wyrazona w postaci suma wektorowa skutecznych, wazonych czestotliwosciowo przyspieszen drgan wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz);, Exposure lasting 30 min. and less expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz);, Exposure lasting 30 min. and less expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a83b305af14b9c0e7b20b67","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy – drgania o działaniu ogólnym na organizm człowieka.","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,015 - 35) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia; Metoda próbkowania","techniques":["Metoda pomiarowa bezpośrednia","Metoda próbkowania"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,015 - 35) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o działaniu ogólnym na organizm człowieka. Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,015 - 35) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania PN-EN 14253+A1:2011 Srodowisko pracy – drgania o dzialaniu ogolnym na organizm czlowieka. Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,015 - 35) m/s2\nMetoda pomiarowa bezposrednia; Metoda probkowania PN-EN 14253+A1:2011","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,015 - 35) m/s2"}],"search_en":"Workplace environment – whole-body vibration. Frequency-weighted r.m.s. vibration acceleration Direct measurement method; Sampling method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method; Sampling method","test_object_en":"Workplace environment – whole-body vibration.","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,015 - 35) m/s2"}],"search_zh":"频率计权振动加速度有效值 直接测量法；采样法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法；采样法"},{"_id":"6a83b305af14b9c0e7b20b68","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy – drgania o działaniu ogólnym na organizm człowieka.","methodology":"Ekspozycja dzienna wyrażona w postaci równoważonego energetycznie dla 8 godzin działania skutecznego, ważonego częstotliwościowo przyspieszenia drgań dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 min. i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych w uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna wyrażona w postaci równoważonego energetycznie dla 8 godzin działania skutecznego, ważonego częstotliwościowo przyspieszenia drgań dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 min. i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych w uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o działaniu ogólnym na organizm człowieka. Ekspozycja dzienna wyrażona w postaci równoważonego energetycznie dla 8 godzin działania skutecznego, ważonego częstotliwościowo przyspieszenia drgań dominującego wśród przyśpieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 min. i krócej wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych w uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o dzialaniu ogolnym na organizm czlowieka. Ekspozycja dzienna wyrazona w postaci rownowazonego energetycznie dla 8 godzin dzialania skutecznego, wazonego czestotliwosciowo przyspieszenia drgan dominujacego wsrod przyspieszen drgan wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 min. i krocej wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych w uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 min. and less expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration. Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 min. and less expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration."},{"_id":"6a83b305af14b9c0e7b20b69","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","norm_bases":["PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 10000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 10000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b305af14b9c0e7b20b6a","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","norm_bases":["PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b305af14b9c0e7b20b6b","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie światłem elektrycznym na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","norm_bases":["PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie światłem elektrycznym na zewnątrz Natężenie oświetlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezpośrednia PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r. Srodowisko pracy - oswietlenie swiatlem elektrycznym na zewnatrz Natezenie oswietlenia\nZakres (0,5 - 10000) lx\nMetoda pomiarowa bezposrednia PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 10000) lx"}],"search_en":"Workplace environment - outdoor electric lighting Illuminance Direct measurement method Range PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - outdoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 10000) lx"}],"search_zh":"照度 直接测量法 范围 PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","technique_zh":"直接测量法"},{"_id":"6a83b305af14b9c0e7b20b6c","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie światłem elektrycznym na zewnątrz","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","norm_bases":["PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie światłem elektrycznym na zewnątrz Równomierność oświetlenia (z obliczeń) PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r. Srodowisko pracy - oswietlenie swiatlem elektrycznym na zewnatrz Rownomiernosc oswietlenia (z obliczen) PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - outdoor electric lighting Illuminance uniformity (calculated) PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r.","test_object_en":"Workplace environment - outdoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值） PN-EN 12464-2:2014-05 PB/LHP/04 wydanie 2 z dnia 01.06.2023 r."},{"_id":"6a83b305af14b9c0e7b20b6d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 1000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 1000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne awaryjne Natężenie oświetlenia\nZakres (0,5 - 1000) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. Srodowisko pracy - oswietlenie elektryczne awaryjne Natezenie oswietlenia\nZakres (0,5 - 1000) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 1000) lx"}],"search_en":"Workplace environment - emergency electric lighting Illuminance Direct measurement method Range PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 1000) lx"}],"search_zh":"工作环境 － 应急电气照明 照度 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a83b305af14b9c0e7b20b6e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. Srodowisko pracy - oswietlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment - emergency electric lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_en":"Workplace environment - emergency electric lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作环境 － 应急电气照明 最小与最大照度之比（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a83b305af14b9c0e7b20b6f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5. Srodowisko pracy - oswietlenie elektryczne awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment - emergency electric lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_en":"Workplace environment - emergency electric lighting","methodology_zh":"高风险区照度均匀度（计算值）","search_zh":"工作环境 － 应急电气照明 高风险区照度均匀度（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt.: 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.8-4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_zh":"工作环境 － 应急电气照明"},{"_id":"6a83b305af14b9c0e7b20b70","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(10 - 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nWilgotność powietrza\nZakres (10 - 90) %\nPrędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nWilgotność powietrza\nZakres (10 - 90) %\nPrędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 40) °C\nWilgotnosc powietrza\nZakres (10 - 90) %\nPredkosc powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(10 - 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(10 - 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b305af14b9c0e7b20b71","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b305af14b9c0e7b20b72","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-25 do +10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-25 do +10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(15 - 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 4) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-25 do +10) °C\nTemperatura poczernionej kuli\nZakres (-25 do +10) °C\nWilgotność powietrza\nZakres (15 - 90) %\nPrędkość powietrza\nZakres (0,15 - 4) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-25 do +10) °C\nTemperatura poczernionej kuli\nZakres (-25 do +10) °C\nWilgotność powietrza\nZakres (15 - 90) %\nPrędkość powietrza\nZakres (0,15 - 4) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-25 do +10) °C\nTemperatura poczernionej kuli\nZakres (-25 do +10) °C\nWilgotnosc powietrza\nZakres (15 - 90) %\nPredkosc powietrza\nZakres (0,15 - 4) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-25 do +10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-25 do +10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(15 - 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 4) m/s"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-25 do +10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-25 do +10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(15 - 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 4) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83b305af14b9c0e7b20b73","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a83b305af14b9c0e7b20b74","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(+20 do +50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(+10 do +50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(+20 do +60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (+20 do +50) °C\nTemperatura wilgotna naturalna\nZakres (+10 do +50) °C\nTemperatura poczernionej kuli\nZakres (+20 do +60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (+20 do +50) °C\nTemperatura wilgotna naturalna\nZakres (+10 do +50) °C\nTemperatura poczernionej kuli\nZakres (+20 do +60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (+20 do +50) °C\nTemperatura wilgotna naturalna\nZakres (+10 do +50) °C\nTemperatura poczernionej kuli\nZakres (+20 do +60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(+20 do +50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(+10 do +50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(+20 do +60) °C"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(+20 do +50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(+10 do +50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(+20 do +60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b305af14b9c0e7b20b75","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b305af14b9c0e7b20b76","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – wentylacja","methodology":"Prędkość strumienia powietrza – na elementach końcowych","parameters":[{"name":"Zakres","range":"(0,20 - 20,0) m/s"},{"name":"Zakres","range":"(0,15 - 20,0) m/s"}],"technique":"Metoda pomiaru anemometrem skrzydełkowym.; Metoda pomiarowa bezpośrednia – w przekroju poprzecznym przewodu wentylacyjnego; Metoda pomiaru termoanemometrem.; Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiaru anemometrem skrzydełkowym.","Metoda pomiarowa bezpośrednia – w przekroju poprzecznym przewodu wentylacyjnego","Metoda pomiaru termoanemometrem.","Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Prędkość strumienia powietrza – na elementach końcowych\nZakres:\nZakres (0,20 - 20,0) m/s\nZakres (0,15 - 20,0) m/s\nMetoda pomiaru anemometrem skrzydełkowym.; Metoda pomiarowa bezpośrednia – w przekroju poprzecznym przewodu wentylacyjnego; Metoda pomiaru termoanemometrem.; Metoda pomiarowa bezpośrednia","reference":"PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","norm_bases":["PN-EN 12599:2013-04","PN-83/B-03430","PN-67/B-03432"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – wentylacja Prędkość strumienia powietrza – na elementach końcowych\nZakres:\nZakres (0,20 - 20,0) m/s\nZakres (0,15 - 20,0) m/s\nMetoda pomiaru anemometrem skrzydełkowym.; Metoda pomiarowa bezpośrednia – w przekroju poprzecznym przewodu wentylacyjnego; Metoda pomiaru termoanemometrem.; Metoda pomiarowa bezpośrednia PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – wentylacja Predkosc strumienia powietrza – na elementach koncowych\nZakres:\nZakres (0,20 - 20,0) m/s\nZakres (0,15 - 20,0) m/s\nMetoda pomiaru anemometrem skrzydelkowym.; Metoda pomiarowa bezposrednia – w przekroju poprzecznym przewodu wentylacyjnego; Metoda pomiaru termoanemometrem.; Metoda pomiarowa bezposrednia PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air stream velocity – at terminal devices","parameters_en":[{"name":"Range","range":"(0,20 - 20,0) m/s"},{"name":"Range","range":"(0,15 - 20,0) m/s"}],"search_en":"Rooms in residential, collective residence and public buildings – ventilation Air stream velocity – at terminal devices Measurement method with a vane anemometer.; Direct measurement method – in the cross-section of the ventilation duct; Measurement method with a thermoanemometer.; Direct measurement method Range Range PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","technique_en":"Measurement method with a vane anemometer.; Direct measurement method – in the cross-section of the ventilation duct; Measurement method with a thermoanemometer.; Direct measurement method","test_object_en":"Rooms in residential, collective residence and public buildings – ventilation","parameters_zh":[{"name":"范围","range":"(0,20 - 20,0) m/s"},{"name":"范围","range":"(0,15 - 20,0) m/s"}],"search_zh":"住宅、集体居住与公共建筑内的房间 － 通风 范围 范围 PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 通风"},{"_id":"6a83b305af14b9c0e7b20b77","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – wentylacja","methodology":"Strumień objętości powietrza, Krotność wymian powietrza (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Strumień objętości powietrza, Krotność wymian powietrza (z obliczeń)","reference":"PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","norm_bases":["PN-EN 12599:2013-04","PN-83/B-03430","PN-67/B-03432"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – wentylacja Strumień objętości powietrza, Krotność wymian powietrza (z obliczeń) PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – wentylacja Strumien objetosci powietrza, Krotnosc wymian powietrza (z obliczen) PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air volume flow rate, Air change rate (calculated)","search_en":"Rooms in residential, collective residence and public buildings – ventilation Air volume flow rate, Air change rate (calculated) PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","test_object_en":"Rooms in residential, collective residence and public buildings – ventilation","search_zh":"住宅、集体居住与公共建筑内的房间 － 通风 PN-EN 12599:2013-04 | PN-83/B-03430 | PN-67/B-03432","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 通风"},{"_id":"6a83b305af14b9c0e7b20b78","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"azbest"},{"name":"włókna respirabilne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nazbest\nwłókna respirabilne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nazbest\nwłókna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nazbest\nwlokna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"asbestos"},{"name":"respirable fibres"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction asbestos respirable fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，其中包括可吸入性粉尘"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"石棉"},{"name":"呼吸性纤维"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 有机物质，其中包括可吸入性粉尘 无机物质，包括 可吸入组分 呼吸性组分 胸腔组分 金属及其化合物，包括 可吸入组分 呼吸性组分 石棉 呼吸性纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b305af14b9c0e7b20b79","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne"},{"name":"substancje nieorganiczne"},{"name":"frakcja wdychalna"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne\nfrakcja wdychalna\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne\nsubstancje nieorganiczne\nfrakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances"},{"name":"inorganic substances"},{"name":"inhalable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Stationary method organic substances inorganic substances inhalable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","technique_en":"Stationary method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"有机物质"},{"name":"无机物质"},{"name":"可吸入组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点测定法 有机物质 无机物质 可吸入组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","technique_zh":"定点测定法"},{"_id":"6a83b305af14b9c0e7b20b7a","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b305af14b9c0e7b20b7b","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie gazów","parameters":[{"name":"CO","range":"(2,3 - 236,0) mg/m3"},{"name":"Zakres","range":"(2,0 - 203) ppm"},{"name":"NO","range":"(0,37 - 7,49) mg/m3"},{"name":"(0,3 - 6,0) ppm"},{"name":"NO2","range":"(0,38 - 3,83) mg/m3"},{"name":"(0,2 - 2,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\nCO (2,3 - 236,0) mg/m3\nZakres (2,0 - 203) ppm\nNO (0,37 - 7,49) mg/m3\n(0,3 - 6,0) ppm\nNO2 (0,38 - 3,83) mg/m3\n(0,2 - 2,0) ppm\nMetoda elektrochemiczna","reference":"PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","norm_bases":["PB/LHP/03 wydanie 10 z dnia 01.03.2026 r."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie gazów\nZakres:\nCO (2,3 - 236,0) mg/m3\nZakres (2,0 - 203) ppm\nNO (0,37 - 7,49) mg/m3\n(0,3 - 6,0) ppm\nNO2 (0,38 - 3,83) mg/m3\n(0,2 - 2,0) ppm\nMetoda elektrochemiczna PB/LHP/03 wydanie 10 z dnia 01.03.2026 r. Srodowisko pracy - powietrze Stezenie gazow\nZakres:\nCO (2,3 - 236,0) mg/m3\nZakres (2,0 - 203) ppm\nNO (0,37 - 7,49) mg/m3\n(0,3 - 6,0) ppm\nNO2 (0,38 - 3,83) mg/m3\n(0,2 - 2,0) ppm\nMetoda elektrochemiczna PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas concentrations","parameters_en":[{"name":"CO","range":"(2,3 - 236,0) mg/m3"},{"name":"Range","range":"(2,0 - 203) ppm"},{"name":"NO","range":"(0,37 - 7,49) mg/m3"},{"name":"(0,3 - 6,0) ppm"},{"name":"NO2","range":"(0,38 - 3,83) mg/m3"},{"name":"(0,2 - 2,0) ppm"}],"search_en":"Workplace environment - air Gas concentrations Electrochemical method CO Range NO (0,3 - 6,0) ppm NO2 (0,2 - 2,0) ppm PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"CO","range":"(2,3 - 236,0) mg/m3"},{"name":"范围","range":"(2,0 - 203) ppm"},{"name":"NO","range":"(0,37 - 7,49) mg/m3"},{"name":"(0,3 - 6,0) ppm"},{"name":"NO2","range":"(0,38 - 3,83) mg/m3"},{"name":"(0,2 - 2,0) ppm"}],"search_zh":"工作场所环境 — 空气 气体浓度 电化学法 CO 范围 NO NO2 PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"气体浓度"},{"_id":"6a83b305af14b9c0e7b20b7c","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","norm_bases":["PB/LHP/03 wydanie 10 z dnia 01.03.2026 r."],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB/LHP/03 wydanie 10 z dnia 01.03.2026 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB/LHP/03 wydanie 10 z dnia 01.03.2026 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a83b305af14b9c0e7b20b7d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie/zawartość krystalicznej krzemionki: kwarc i krystobalit","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0088 - 0,88) mg/m3"},{"name":"Zakres","range":"(0,0060 - 0,60) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Stężenie/zawartość krystalicznej krzemionki: kwarc i krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,0088 - 0,88) mg/m3\nZakres (0,0060 - 0,60) mg w próbce\nMetoda spektrometrii w podczerwieni","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie/zawartość krystalicznej krzemionki: kwarc i krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,0088 - 0,88) mg/m3\nZakres (0,0060 - 0,60) mg w próbce\nMetoda spektrometrii w podczerwieni Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130 Srodowisko pracy - powietrze Stezenie/zawartosc krystalicznej krzemionki: kwarc i krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,0088 - 0,88) mg/m3\nZakres (0,0060 - 0,60) mg w probce\nMetoda spektrometrii w podczerwieni Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4 (74), s. 117-130","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of crystalline silica: quartz and cristobalite","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,0088 - 0,88) mg/m3"},{"name":"Range","range":"(0,0060 - 0,60) mg w próbce"}],"search_en":"Workplace environment - air Concentration/content of crystalline silica: quartz and cristobalite Infrared spectrometry method respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130","technique_en":"Infrared spectrometry method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0088 - 0,88) mg/m3"},{"name":"范围","range":"(0,0060 - 0,60) mg w próbce"}],"search_zh":"工作场所环境 — 空气 红外光谱法 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130","technique_zh":"红外光谱法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b305af14b9c0e7b20b7e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit: a) grafit naturalny b) grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna:"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu, wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,18 - 17,04) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit: a) grafit naturalny b) grafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,18 - 17,04) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit: a) grafit naturalny b) grafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,18 - 17,04) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit: a) grafit naturalny b) grafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna:\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu, wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,18 - 17,04) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Graphite: a) natural graphite b) synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica:"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Carbon black"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Magnesium, calcium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,18 - 17,04) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction: Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Graphite: a) natural graphite b) synthetic graphite Kaolin Amorphous and synthetic silica: Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Talc Coal (hard, brown) Magnesium, calcium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"Grafit: a) grafit naturalny b) grafit syntetyczny"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅："},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"镁钙碳酸盐（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,18 - 17,04) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 高岭土 无定形与合成二氧化硅： 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 镁钙碳酸盐（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83b305af14b9c0e7b20b7f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna :","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna:"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,07 - 7,35) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna :\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,07 - 7,35) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna :\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,07 - 7,35) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna :\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna:\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,07 - 7,35) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction :","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica:"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,07 - 7,35) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction : Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica: Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅："},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,07 - 7,35) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅： 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b305af14b9c0e7b20b80","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazów odlotowych (> 10 Pa) w zakresie ciśnienia dynamicznego)","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazów odlotowych (> 10 Pa) w zakresie ciśnienia dynamicznego)\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazów odlotowych (> 10 Pa) w zakresie ciśnienia dynamicznego)\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazow odlotowych (> 10 Pa) w zakresie cisnienia dynamicznego)\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Waste gas volume flow rate (> 10 Pa) in the dynamic pressure range)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Waste gas volume flow rate (> 10 Pa) in the dynamic pressure range) Stagnation pressure method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 滞止压力法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04030-7:1994","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"滞止压力法"},{"_id":"6a83b305af14b9c0e7b20b81","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of dust concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b82","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 - 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 - 100) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b83","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Dust emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b84","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Prędkość","parameters":[{"name":"Zakres","range":"(0,5 - 10) m/s"}],"technique":"Metoda anemometryczna","techniques":["Metoda anemometryczna"],"computed":[],"activity":"Prędkość\nZakres (0,5 - 10) m/s\nMetoda anemometryczna","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 | PN-Z-04030-7:1994","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Prędkość\nZakres (0,5 - 10) m/s\nMetoda anemometryczna PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 | PN-Z-04030-7:1994 Gazy odlotowe Predkosc\nZakres (0,5 - 10) m/s\nMetoda anemometryczna PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 | PN-Z-04030-7:1994","categories":["other"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Velocity","parameters_en":[{"name":"Range","range":"(0,5 - 10) m/s"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Velocity Anemometric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 | PN-Z-04030-7:1994","technique_en":"Anemometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,5 - 10) m/s"}],"search_zh":"废气 速度 风速仪法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 | PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"速度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"风速仪法"},{"_id":"6a83b305af14b9c0e7b20b85","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenia NO, NOx (NO2), SO2, CO, CO2, O2","parameters":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx w przeliczeniu na NO2"},{"name":"Zakres","range":"(1,24 - 5000) mg/m3"},{"name":"SO2","range":"(10,0 - 6000) mg/m3"},{"name":"CO","range":"(3,0 - 6000) mg/m3"},{"name":"CO2","range":"(0,5 - 30) %"},{"name":"O2","range":"(2,0 - 21) %"}],"technique":"Metoda chemiluminescencyjna (CLD); Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda elektrochemiczna","techniques":["Metoda chemiluminescencyjna (CLD)","Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","Metoda elektrochemiczna"],"computed":[],"activity":"Stężenia NO, NOx (NO2), SO2, CO, CO2, O2\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx w przeliczeniu na NO2\nZakres (1,24 - 5000) mg/m3\nSO2 (10,0 - 6000) mg/m3\nCO (3,0 - 6000) mg/m3\nCO2 (0,5 - 30) %\nO2 (2,0 - 21) %\nMetoda chemiluminescencyjna (CLD); Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenia NO, NOx (NO2), SO2, CO, CO2, O2\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx w przeliczeniu na NO2\nZakres (1,24 - 5000) mg/m3\nSO2 (10,0 - 6000) mg/m3\nCO (3,0 - 6000) mg/m3\nCO2 (0,5 - 30) %\nO2 (2,0 - 21) %\nMetoda chemiluminescencyjna (CLD); Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenia NO, NOx (NO2), SO2, CO, CO2, O2\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx w przeliczeniu na NO2\nZakres (1,24 - 5000) mg/m3\nSO2 (10,0 - 6000) mg/m3\nCO (3,0 - 6000) mg/m3\nCO2 (0,5 - 30) %\nO2 (2,0 - 21) %\nMetoda chemiluminescencyjna (CLD); Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR); Metoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx (NO2), SO2, CO, CO2, O2 concentrations","parameters_en":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx expressed as NO2"},{"name":"Range","range":"(1,24 - 5000) mg/m3"},{"name":"SO2","range":"(10,0 - 6000) mg/m3"},{"name":"CO","range":"(3,0 - 6000) mg/m3"},{"name":"CO2","range":"(0,5 - 30) %"},{"name":"O2","range":"(2,0 - 21) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases NO, NOx (NO2), SO2, CO, CO2, O2 concentrations Chemiluminescence method (CLD); Non-dispersive infrared spectrometry method (NDIR); Electrochemical method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. NO NOx expressed as NO2 Range SO2 CO CO2 O2 PN-ISO 10396:2001","technique_en":"Chemiluminescence method (CLD); Non-dispersive infrared spectrometry method (NDIR); Electrochemical method","test_object_en":"Waste gases","parameters_zh":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx w przeliczeniu na NO2"},{"name":"范围","range":"(1,24 - 5000) mg/m3"},{"name":"SO2","range":"(10,0 - 6000) mg/m3"},{"name":"CO","range":"(3,0 - 6000) mg/m3"},{"name":"CO2","range":"(0,5 - 30) %"},{"name":"O2","range":"(2,0 - 21) %"}],"search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. NO 范围 SO2 CO CO2 O2 PN-ISO 10396:2001","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b86","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO2), SO2, CO, CO2, O2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO2), SO2, CO, CO2, O2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO2), SO2, CO, CO2, O2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja NO, NOx (NO2), SO2, CO, CO2, O2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of NO, NOx (NO2), SO2, CO, CO2, O2 (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of NO, NOx (NO2), SO2, CO, CO2, O2 (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b87","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(1,0 - 21,0) %"}],"technique":"Metoda paramagnetyczna (PMD)","techniques":["Metoda paramagnetyczna (PMD)"],"computed":[],"activity":"Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna (PMD)","reference":"PN-ISO 10396:2001 | PN-EN 14789:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14789:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna (PMD) PN-ISO 10396:2001 | PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna (PMD) PN-ISO 10396:2001 | PN-EN 14789:2017-04","categories":["other"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(1,0 - 21,0) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Oxygen concentration Paramagnetic method (PMD) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-ISO 10396:2001 | PN-EN 14789:2017-04","technique_en":"Paramagnetic method (PMD)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 21,0) %"}],"search_zh":"废气 氧浓度 顺磁法（PMD） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-ISO 10396:2001 | PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"顺磁法（PMD）"},{"_id":"6a83b305af14b9c0e7b20b88","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja O2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja O2 (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 14789:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14789:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja O2 (z obliczeń) PN-ISO 10396:2001 | PN-EN 14789:2017-04 Gazy odlotowe Emisja O2 (z obliczen) PN-ISO 10396:2001 | PN-EN 14789:2017-04","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"O2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases O2 emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001 | PN-EN 14789:2017-04","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001 | PN-EN 14789:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b89","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenia CO, SO2, NO, NO2, CO2, O2","parameters":[{"name":"CO","range":"(3,0 - 50000) mg/m3"},{"name":"SO2","range":"(4,0 - 4500) mg/m3"},{"name":"NO","range":"(3,0 - 1000) mg/m3"},{"name":"NO2","range":"(3,0 - 200) mg/m3"},{"name":"CO2","range":"(0,5 - 30) %"},{"name":"O2","range":"(2,0 - 22) %"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR); Metoda celi cyrkonowej,","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","Metoda celi cyrkonowej,"],"computed":[],"activity":"Stężenia CO, SO2, NO, NO2, CO2, O2\nZakres:\nCO (3,0 - 50000) mg/m3\nSO2 (4,0 - 4500) mg/m3\nNO (3,0 - 1000) mg/m3\nNO2 (3,0 - 200) mg/m3\nCO2 (0,5 - 30) %\nO2 (2,0 - 22) %\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR); Metoda celi cyrkonowej,","reference":"PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","norm_bases":["PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenia CO, SO2, NO, NO2, CO2, O2\nZakres:\nCO (3,0 - 50000) mg/m3\nSO2 (4,0 - 4500) mg/m3\nNO (3,0 - 1000) mg/m3\nNO2 (3,0 - 200) mg/m3\nCO2 (0,5 - 30) %\nO2 (2,0 - 22) %\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR); Metoda celi cyrkonowej, PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r. Gazy odlotowe Stezenia CO, SO2, NO, NO2, CO2, O2\nZakres:\nCO (3,0 - 50000) mg/m3\nSO2 (4,0 - 4500) mg/m3\nNO (3,0 - 1000) mg/m3\nNO2 (3,0 - 200) mg/m3\nCO2 (0,5 - 30) %\nO2 (2,0 - 22) %\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR); Metoda celi cyrkonowej, PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","categories":["other"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO, SO2, NO, NO2, CO2, O2 concentrations","parameters_en":[{"name":"CO","range":"(3,0 - 50000) mg/m3"},{"name":"SO2","range":"(4,0 - 4500) mg/m3"},{"name":"NO","range":"(3,0 - 1000) mg/m3"},{"name":"NO2","range":"(3,0 - 200) mg/m3"},{"name":"CO2","range":"(0,5 - 30) %"},{"name":"O2","range":"(2,0 - 22) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases CO, SO2, NO, NO2, CO2, O2 concentrations Fourier transform infrared spectroscopy method (FTIR); Zirconia cell method, Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. CO SO2 NO NO2 CO2 O2 PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","technique_en":"Fourier transform infrared spectroscopy method (FTIR); Zirconia cell method,","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. CO SO2 NO NO2 CO2 O2 PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","test_object_zh":"废气","parameters_zh":[{"name":"CO","range":"(3,0 - 50000) mg/m3"},{"name":"SO2","range":"(4,0 - 4500) mg/m3"},{"name":"NO","range":"(3,0 - 1000) mg/m3"},{"name":"NO2","range":"(3,0 - 200) mg/m3"},{"name":"CO2","range":"(0,5 - 30) %"},{"name":"O2","range":"(2,0 - 22) %"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b8a","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO2), NO2, SO2, CO, CO2 (z obliczeń )","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO2), NO2, SO2, CO, CO2 (z obliczeń )","reference":"PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","norm_bases":["PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO2), NO2, SO2, CO, CO2 (z obliczeń ) PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r. Gazy odlotowe Emisja NO, NOx (NO2), NO2, SO2, CO, CO2 (z obliczen ) PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of NO, NOx (NO2), NO2, SO2, CO, CO2 (calculated )","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of NO, NOx (NO2), NO2, SO2, CO, CO2 (calculated ) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b8b","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(3,0 - 500) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (3,0 - 500) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (3,0 - 500) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (3,0 - 500) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(3,0 - 500) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(3,0 - 500) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a83b305af14b9c0e7b20b8c","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 12619:2013-05","test_object_en":"Waste gases","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b8d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężeń masowych: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężeń masowych: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężeń masowych: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczenia stezen masowych: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05","categories":["other"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the mass concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of the mass concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14385:2025-05","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14385:2025-05","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b8e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2025-05","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14385:2025-05","test_object_en":"Waste gases","search_zh":"废气 As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14385:2025-05","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20b8f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężenia rtęci ogólnej","parameters":[],"technique":"Metoda filtracyjno-aspiracyjna","techniques":["Metoda filtracyjno-aspiracyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia rtęci ogólnej\nMetoda filtracyjno-aspiracyjna","reference":"PN-EN 13211+ AC:2006","norm_bases":["PN-EN 13211+ AC:2006"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia rtęci ogólnej\nMetoda filtracyjno-aspiracyjna PN-EN 13211+ AC:2006 Gazy odlotowe Pobieranie probek do oznaczenia stezenia rteci ogolnej\nMetoda filtracyjno-aspiracyjna PN-EN 13211+ AC:2006","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of total mercury concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for the determination of total mercury concentration Filtration-aspiration method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13211+ AC:2006","technique_en":"Filtration-aspiration method","test_object_en":"Waste gases","search_zh":"废气 用于测定总汞浓度的采样 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13211+ AC:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"用于测定总汞浓度的采样"},{"_id":"6a83b305af14b9c0e7b20b90","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+ AC:2006","norm_bases":["PN-EN 13211+ AC:2006"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+ AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+ AC:2006","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mercury emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Total mercury emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13211+ AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13211+ AC:2006","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b91","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia masowego stężenia PCDD/PCDFs oraz PCB typu dioksyn","parameters":[],"technique":"Metoda filtracyjno-kondensacyjna","techniques":["Metoda filtracyjno-kondensacyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczenia masowego stężenia PCDD/PCDFs oraz PCB typu dioksyn\nMetoda filtracyjno-kondensacyjna","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia masowego stężenia PCDD/PCDFs oraz PCB typu dioksyn\nMetoda filtracyjno-kondensacyjna PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 Gazy odlotowe Pobieranie probek do oznaczenia masowego stezenia PCDD/PCDFs oraz PCB typu dioksyn\nMetoda filtracyjno-kondensacyjna PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCB","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCB Filtration-condensation method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","technique_en":"Filtration-condensation method","test_object_en":"Waste gases","search_zh":"废气 过滤-冷凝法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"过滤-冷凝法"},{"_id":"6a83b305af14b9c0e7b20b92","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja PCDD/PCDFs oraz PCB typu dioksyn (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja PCDD/PCDFs oraz PCB typu dioksyn (z obliczeń)","reference":"PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-1:2006","PN-EN 1948-4+A1:2014-03"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja PCDD/PCDFs oraz PCB typu dioksyn (z obliczeń) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03 Gazy odlotowe Emisja PCDD/PCDFs oraz PCB typu dioksyn (z obliczen) PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of PCDD/PCDFs and dioxin-like PCBs (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of PCDD/PCDFs and dioxin-like PCBs (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1948-1:2006 | PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b93","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężenia HCI","parameters":[],"technique":"Metoda aspiracyjna","techniques":["Metoda aspiracyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia HCI\nMetoda aspiracyjna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia HCI\nMetoda aspiracyjna PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczenia stezenia HCI\nMetoda aspiracyjna PN-EN 1911:2011","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of HCI concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of HCI concentration Aspiration method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1911:2011","technique_en":"Aspiration method","test_object_en":"Waste gases","search_zh":"废气 抽气法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1911:2011","test_object_zh":"废气","technique_zh":"抽气法","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b94","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie chlorowodoru HCl","parameters":[{"name":"Zakres","range":"(1,0 - 300,0) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorowodoru HCl\nZakres (1,0 - 300,0) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie chlorowodoru HCl\nZakres (1,0 - 300,0) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie chlorowodoru HCl\nZakres (1,0 - 300,0) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration HCl","parameters_en":[{"name":"Range","range":"(1,0 - 300,0) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Hydrogen chloride concentration HCl Spectrophotometric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 300,0) mg/m3"}],"search_zh":"废气 分光光度法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b95","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HCl (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HCl emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases HCl emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 HCl 排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 1911:2011","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20b96","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężenia HF","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia HF","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia HF ISO 15713:2006 CEN/TS 17340:2020-09 Gazy odlotowe Pobieranie probek do oznaczenia stezenia HF ISO 15713:2006 CEN/TS 17340:2020-09","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of HF concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of HF concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. ISO 15713:2006 CEN/TS 17340:2020-09","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. ISO 15713:2006 CEN/TS 17340:2020-09","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b97","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków fluoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków fluoru (z obliczeń)","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja związków fluoru (z obliczeń) ISO 15713:2006 CEN/TS 17340:2020-09 Gazy odlotowe Emisja zwiazkow fluoru (z obliczen) ISO 15713:2006 CEN/TS 17340:2020-09","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of fluorine compounds (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of fluorine compounds (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. ISO 15713:2006 CEN/TS 17340:2020-09","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. ISO 15713:2006 CEN/TS 17340:2020-09","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b98","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężenia indywidualnych gazowych związków organicznych.","parameters":[],"technique":"Metoda z zastosowaniem węgla aktywnego.","techniques":["Metoda z zastosowaniem węgla aktywnego."],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia indywidualnych gazowych związków organicznych.\nMetoda z zastosowaniem węgla aktywnego.","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia indywidualnych gazowych związków organicznych.\nMetoda z zastosowaniem węgla aktywnego. PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczenia stezenia indywidualnych gazowych zwiazkow organicznych.\nMetoda z zastosowaniem wegla aktywnego. PN-EN 13649:2005","categories":["other"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds.","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds. Method using activated carbon. Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13649:2005","technique_en":"Method using activated carbon.","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13649:2005","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b99","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13649:2005","test_object_en":"Waste gases","search_zh":"废气 单项气态有机化合物排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b9a","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych PN-Z-04008-4:1999","categories":["other"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of concentrations of organic compounds","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of concentrations of organic compounds Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 有机化合物浓度测定采样 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04008-4:1999","test_object_zh":"废气","methodology_zh":"有机化合物浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b9b","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja zanieczyszczeń (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja zanieczyszczeń (z obliczeń)","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja zanieczyszczeń (z obliczeń) PN-Z-04008-4:1999 Gazy odlotowe Emisja zanieczyszczen (z obliczen) PN-Z-04008-4:1999","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of pollutants (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Emission of pollutants (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04008-4:1999","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-Z-04008-4:1999","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b9c","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych >5 Pa","parameters":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"computed":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych >5 Pa\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych >5 Pa\nMetoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych >5 Pa\nMetoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","categories":["other"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas velocity and volumetric flow rate for differential pressures >5 Pa","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Gas velocity and volumetric flow rate for differential pressures >5 Pa Differential pressure measurement method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","technique_en":"Differential pressure measurement method","test_object_en":"Waste gases","search_zh":"废气 差压测量法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"差压测量法"},{"_id":"6a83b305af14b9c0e7b20b9d","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of dust concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b9e","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,64 - 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,64 - 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,64 - 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,64 - 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,64 - 50) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,64 - 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20b9f","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Dust emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20ba0","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia SO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-04","categories":["other"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of SO2 concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Sampling for determination of SO2 concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 用于测定 SO2 浓度的采样 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14791:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a83b305af14b9c0e7b20ba1","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(2,67 - 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO2\nZakres (2,67 - 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (2,67 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie SO2\nZakres (2,67 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(2,67 - 2000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases SO2 concentration Thoron method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-EN 14791:2017-04","technique_en":"Thoron method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2,67 - 2000) mg/m3"}],"search_zh":"废气 SO2 浓度 钍射气法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-EN 14791:2017-04","test_object_zh":"废气","technique_zh":"钍射气法","methodology_zh":"SO2 浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20ba2","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases SO2 emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 SO2 排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20ba3","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie NO, NOx (NO i NO2 w przeliczeniu na NO2)","parameters":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx","range":"(1,24 - 5000) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie NO, NOx (NO i NO2 w przeliczeniu na NO2)\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx (1,24 - 5000) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie NO, NOx (NO i NO2 w przeliczeniu na NO2)\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx (1,24 - 5000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Gazy odlotowe Stezenie NO, NOx (NO i NO2 w przeliczeniu na NO2)\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx (1,24 - 5000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx concentration (NO and NO2 calculated as NO2)","parameters_en":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx","range":"(1,24 - 5000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases NO, NOx concentration (NO and NO2 calculated as NO2) Chemiluminescence method (CLD) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. NO NOx PN-EN 14792:2017-04","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Waste gases","search_zh":"废气 化学发光法（CLD） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. NO NOx PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx","range":"(1,24 - 5000) mg/m3"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"化学发光法（CLD）"},{"_id":"6a83b305af14b9c0e7b20ba4","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx emission (NO and NO2 calculated as NO2) (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14792:2017-04","test_object_en":"Waste gases","search_zh":"废气 NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14792:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20ba5","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie NO2","parameters":[{"name":"Zakres","range":"(1,24 - 200) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie NO2\nZakres (1,24 - 200) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","norm_bases":["PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie NO2\nZakres (1,24 - 200) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r. Gazy odlotowe Stezenie NO2\nZakres (1,24 - 200) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","categories":["other"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO2 concentration","parameters_en":[{"name":"Range","range":"(1,24 - 200) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases NO2 concentration Chemiluminescence method (CLD) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,24 - 200) mg/m3"}],"search_zh":"废气 NO2 浓度 化学发光法（CLD） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"化学发光法（CLD）","methodology_zh":"NO2 浓度"},{"_id":"6a83b305af14b9c0e7b20ba6","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO2 (z obliczeń)","reference":"PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","norm_bases":["PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja NO2 (z obliczeń) PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r. Gazy odlotowe Emisja NO2 (z obliczen) PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases NO2 emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20ba7","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(3,0 - 6000) mg/m3"}],"technique":"Metoda niedyspersyjnej spektometrii w podczerwieni","techniques":["Metoda niedyspersyjnej spektometrii w podczerwieni"],"computed":[],"activity":"Stężenie CO\nZakres (3,0 - 6000) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni","reference":"PN-ISO 15058:2017-04","norm_bases":["PN-ISO 15058:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie CO\nZakres (3,0 - 6000) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni PN-ISO 15058:2017-04 Gazy odlotowe Stezenie CO\nZakres (3,0 - 6000) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni PN-ISO 15058:2017-04","categories":["other"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(3,0 - 6000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases CO concentration Non-dispersive infrared spectrometry method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-ISO 15058:2017-04","technique_en":"Non-dispersive infrared spectrometry method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(3,0 - 6000) mg/m3"}],"search_zh":"废气 CO 浓度 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-ISO 15058:2017-04","test_object_zh":"废气","methodology_zh":"CO 浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20ba8","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-ISO 15058:2017-04","norm_bases":["PN-ISO 15058:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-ISO 15058:2017-04 Gazy odlotowe Emisja CO (z obliczen) PN-ISO 15058:2017-04","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases CO emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 15058:2017-04","test_object_en":"Waste gases","search_zh":"废气 CO 排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 15058:2017-04","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20ba9","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(0,5 - 30) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO2\nZakres (0,5 - 30) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie CO2\nZakres (0,5 - 30) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Gazy odlotowe Stezenie CO2\nZakres (0,5 - 30) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(0,5 - 30) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases CO2 concentration Non-dispersive infrared spectrometry (NDIR) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range ISO 12039:2019","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,5 - 30) %"}],"search_zh":"废气 CO2 浓度 非分散红外光谱法（NDIR） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 ISO 12039:2019","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"CO2 浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska."},{"_id":"6a83b305af14b9c0e7b20baa","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO2 (z obliczeń)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja CO2 (z obliczeń) ISO 12039:2019 Gazy odlotowe Emisja CO2 (z obliczen) ISO 12039:2019","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases CO2 emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. ISO 12039:2019","test_object_en":"Waste gases","search_zh":"废气 CO2 排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. ISO 12039:2019","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"CO2 排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20bab","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(4,0 - 40,0) %"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(4,0 - 40,0) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. Range PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(4,0 - 40,0) %"}],"search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. 范围 PN-EN 14790:2017-04","test_object_zh":"废气","methodology_zh":"水蒸气浓度（H2O）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","technique_zh":"冷凝-吸附法"},{"_id":"6a83b305af14b9c0e7b20bac","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, tlenków azotu","parameters":[{"name":"NO","range":"(3,5 - 3268) mg/m3"},{"name":"NOx","range":"(5,4 - 5000) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (3,5 - 3268) mg/m3\nNOx (5,4 - 5000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (3,5 - 3268) mg/m3\nNOx (5,4 - 5000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (3,5 - 3268) mg/m3\nNOx (5,4 - 5000) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters_en":[{"name":"NO","range":"(3,5 - 3268) mg/m3"},{"name":"NOx","range":"(5,4 - 5000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Non-dispersive infrared spectrometry (NDIR) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. NO NOx PN-ISO 10396:2001","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","search_zh":"废气 一氧化氮、氮氧化物浓度 非分散红外光谱法（NDIR） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. NO NOx PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(3,5 - 3268) mg/m3"},{"name":"NOx","range":"(5,4 - 5000) mg/m3"}],"technique_zh":"非分散红外光谱法（NDIR）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"一氧化氮、氮氧化物浓度"},{"_id":"6a83b305af14b9c0e7b20bad","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx emission (NO and NO2 calculated as NO2) (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","search_en":"Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. PN-ISO 10396:2001","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","methodology_zh":"NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20bae","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (TVOC), HCl, HF, Hg, NO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (TVOC), HCl, HF, Hg, NO2","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (TVOC), HCl, HF, Hg, NO2 PN-EN 14181:2015-02 Automatyczne Systemy Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pylu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (TVOC), HCl, HF, Hg, NO2 PN-EN 14181:2015-02","categories":["metrology"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area PN-EN 14181:2015-02","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） 为受监管领域开展的固定源大气排放定期测量 PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20baf","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Roczne badania kontrolne (AST) w zakresie: pyłu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (TVOC), HCl, HF, Hg, NO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Roczne badania kontrolne (AST) w zakresie: pyłu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (TVOC), HCl, HF, Hg, NO2","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Roczne badania kontrolne (AST) w zakresie: pyłu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (TVOC), HCl, HF, Hg, NO2 PN-EN 14181:2015-02 Automatyczne Systemy Monitoringu (AMS) Roczne badania kontrolne (AST) w zakresie: pylu, SO2, NO, NOx, CO, O2, CO2, H2O, substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (TVOC), HCl, HF, Hg, NO2 PN-EN 14181:2015-02","categories":["other"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area PN-EN 14181:2015-02","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） 为受监管领域开展的固定源大气排放定期测量 PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bb0","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 - 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pyłu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Automatyczne Systemy Monitoringu (AMS) Stezenie pylu\nZakres (0,001 - 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 - 100) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Automated Measuring Systems (AMS)","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 100) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bb1","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,64 - 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,64 - 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pyłu\nZakres (0,64 - 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Automatyczne Systemy Monitoringu (AMS) Stezenie pylu\nZakres (0,64 - 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,64 - 50) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Automated Measuring Systems (AMS)","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,64 - 50) mg/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bb2","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(2,67 - 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO2\nZakres (2,67 - 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie SO2\nZakres (2,67 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie SO2\nZakres (2,67 - 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(2,67 - 2000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) SO2 concentration Thoron method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN 14791:2017-04","technique_en":"Thoron method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(2,67 - 2000) mg/m3"}],"search_zh":"自动测量系统（AMS） SO2 浓度 钍射气法 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN 14791:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"钍射气法","methodology_zh":"SO2 浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bb3","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie NO, NOx","parameters":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx","range":"(1,24 - 5000) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie NO, NOx\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx (1,24 - 5000) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie NO, NOx\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx (1,24 - 5000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie NO, NOx\nZakres:\nNO (0,81 - 3268) mg/m3\nNOx (1,24 - 5000) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx concentration","parameters_en":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx","range":"(1,24 - 5000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) NO, NOx concentration Chemiluminescence method (CLD) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area NO NOx PN-EN 14792:2017-04","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"NO","range":"(0,81 - 3268) mg/m3"},{"name":"NOx","range":"(1,24 - 5000) mg/m3"}],"search_zh":"自动测量系统（AMS） NO、NOx 浓度 化学发光法（CLD） 为受监管领域开展的固定源大气排放定期测量 NO NOx PN-EN 14792:2017-04","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","technique_zh":"化学发光法（CLD）","methodology_zh":"NO、NOx 浓度"},{"_id":"6a83b305af14b9c0e7b20bb4","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie NO2","parameters":[{"name":"Zakres","range":"(1,24 - 200) mg/m3"}],"technique":"Metoda chemiluminescencyjna (CLD)","techniques":["Metoda chemiluminescencyjna (CLD)"],"computed":[],"activity":"Stężenie NO2\nZakres (1,24 - 200) mg/m3\nMetoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","norm_bases":["PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie NO2\nZakres (1,24 - 200) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r. Automatyczne Systemy Monitoringu (AMS) Stezenie NO2\nZakres (1,24 - 200) mg/m3\nMetoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","categories":["other"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO2 concentration","parameters_en":[{"name":"Range","range":"(1,24 - 200) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) NO2 concentration Chemiluminescence method (CLD) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","technique_en":"Chemiluminescence method (CLD)","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(1,24 - 200) mg/m3"}],"search_zh":"自动测量系统（AMS） NO2 浓度 化学发光法（CLD） 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN 14792:2017-04 Procedura badawcza PB/LBP/10 wydanie 1 z dnia 16.01.2024 r.","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","technique_zh":"化学发光法（CLD）","methodology_zh":"NO2 浓度"},{"_id":"6a83b305af14b9c0e7b20bb5","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(3,0 - 6000) mg/m3"}],"technique":"Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie CO\nZakres (3,0 - 6000) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni (NDIR)","reference":"PN-ISO 15058:2017-04","norm_bases":["PN-ISO 15058:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie CO\nZakres (3,0 - 6000) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni (NDIR) PN-ISO 15058:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie CO\nZakres (3,0 - 6000) mg/m3\nMetoda niedyspersyjnej spektometrii w podczerwieni (NDIR) PN-ISO 15058:2017-04","categories":["other"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(3,0 - 6000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) CO concentration Non-dispersive infrared spectrometry (NDIR) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-ISO 15058:2017-04","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(3,0 - 6000) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 非分散红外光谱法（NDIR） 为受监管领域开展的固定源大气排放定期测量 范围 PN-ISO 15058:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO 浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a83b305af14b9c0e7b20bb6","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie O2","parameters":[{"name":"Zakres","range":"(1,0 - 21,0) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie O2\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie O2\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie O2\nZakres (1,0 - 21,0) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"O2 concentration","parameters_en":[{"name":"Range","range":"(1,0 - 21,0) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) O2 concentration Paramagnetic method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN 14789:2017-04","technique_en":"Paramagnetic method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(1,0 - 21,0) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN 14789:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"顺磁法","methodology_zh":"O2 浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bb7","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(0,5 - 30) %"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie CO2\nZakres (0,5 - 30) %\nMetoda NDIR","reference":"ISO 12039:2019 | PN-ISO 10396:2001","norm_bases":["ISO 12039:2019","PN-ISO 10396:2001"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie CO2\nZakres (0,5 - 30) %\nMetoda NDIR ISO 12039:2019 | PN-ISO 10396:2001 Automatyczne Systemy Monitoringu (AMS) Stezenie CO2\nZakres (0,5 - 30) %\nMetoda NDIR ISO 12039:2019 | PN-ISO 10396:2001","categories":["other"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(0,5 - 30) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) CO2 concentration NDIR method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range ISO 12039:2019 | PN-ISO 10396:2001","technique_en":"NDIR method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,5 - 30) %"}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外法（NDIR） 为受监管领域开展的固定源大气排放定期测量 范围 ISO 12039:2019 | PN-ISO 10396:2001","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO2 浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a83b305af14b9c0e7b20bb8","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(4,0 - 40,0) %"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pary wodnej (H2O)\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie pary wodnej (H2O)\nZakres (4,0 - 40,0) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(4,0 - 40,0) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Water vapour concentration (H2O) Condensation-adsorption method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(4,0 - 40,0) %"}],"search_zh":"自动测量系统（AMS） 水蒸气浓度（H2O） 冷凝-吸附法 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN 14790:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"水蒸气浓度（H2O）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","technique_zh":"冷凝-吸附法"},{"_id":"6a83b305af14b9c0e7b20bb9","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(3,0 - 500) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (3,0 - 500) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (3,0 - 500) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Automatyczne Systemy Monitoringu (AMS) Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (3,0 - 500) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(3,0 - 500) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(3,0 - 500) mg/m3"}],"search_zh":"自动测量系统（AMS） 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN 12619:2013-05","test_object_zh":"自动测量系统（AMS）","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a83b305af14b9c0e7b20bba","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie HCl","parameters":[{"name":"Zakres","range":"(1,0 - 300) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie HCl\nZakres (1,0 - 300) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie HCl\nZakres (1,0 - 300) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Automatyczne Systemy Monitoringu (AMS) Stezenie HCl\nZakres (1,0 - 300) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HCl concentration","parameters_en":[{"name":"Range","range":"(1,0 - 300) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) HCl concentration Spectrophotometric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(1,0 - 300) mg/m3"}],"search_zh":"自动测量系统（AMS） HCl 浓度 分光光度法 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","methodology_zh":"HCl 浓度"},{"_id":"6a83b305af14b9c0e7b20bbb","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia HF","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia HF","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia HF ISO 15713:2006 CEN/TS 17340:2020-09 Automatyczne Systemy Monitoringu (AMS) Pobieranie probek do oznaczania stezenia HF ISO 15713:2006 CEN/TS 17340:2020-09","categories":["other"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of HF concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Sampling for determination of HF concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area ISO 15713:2006 CEN/TS 17340:2020-09","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） 用于测定 HF 浓度的采样 为受监管领域开展的固定源大气排放定期测量 ISO 15713:2006 CEN/TS 17340:2020-09","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量","methodology_zh":"用于测定 HF 浓度的采样"},{"_id":"6a83b305af14b9c0e7b20bbc","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia Hg","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia Hg","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia Hg PN-EN 13211+AC:2006 Automatyczne Systemy Monitoringu (AMS) Pobieranie probek do oznaczania stezenia Hg PN-EN 13211+AC:2006","categories":["other"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of Hg concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Sampling for the determination of Hg concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area PN-EN 13211+AC:2006","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） 为受监管领域开展的固定源大气排放定期测量 PN-EN 13211+AC:2006","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bbd","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Pobieranie próbek do oznaczania stężenia NH3","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia NH3","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Pobieranie próbek do oznaczania stężenia NH3 PN-EN ISO 21877:2020-03 Automatyczne Systemy Monitoringu (AMS) Pobieranie probek do oznaczania stezenia NH3 PN-EN ISO 21877:2020-03","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of NH3 concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Sampling for the determination of NH3 concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area PN-EN ISO 21877:2020-03","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） 为受监管领域开展的固定源大气排放定期测量 PN-EN ISO 21877:2020-03","test_object_zh":"自动测量系统（AMS）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bbe","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(0,11 - 157) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (0,11 - 157) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego","flexible":false,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie amoniaku\nZakres (0,11 - 157) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Automatyczne Systemy Monitoringu (AMS) Stezenie amoniaku\nZakres (0,11 - 157) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(0,11 - 157) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area","search_en":"Automated Measuring Systems (AMS) Ammonia concentration Spectrophotometric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,11 - 157) mg/m3"}],"search_zh":"自动测量系统（AMS） 氨浓度 分光光度法 为受监管领域开展的固定源大气排放定期测量 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氨浓度","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量"},{"_id":"6a83b305af14b9c0e7b20bbf","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie NH3","parameters":[{"name":"Zakres","range":"(1,0 - 75) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera FTIR","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera FTIR"],"computed":[],"activity":"Stężenie NH3\nZakres (1,0 - 75) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera FTIR","reference":"PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","norm_bases":["PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie NH3\nZakres (1,0 - 75) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera FTIR PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r. Gazy odlotowe Stezenie NH3\nZakres (1,0 - 75) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera FTIR PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","categories":["other"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NH3 concentration","parameters_en":[{"name":"Range","range":"(1,0 - 75) mg/m3"}],"search_en":"Waste gases NH3 concentration Fourier transform infrared spectroscopy method FTIR Range PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","technique_en":"Fourier transform infrared spectroscopy method FTIR","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 75) mg/m3"}],"search_zh":"废气 NH3 浓度 范围 PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","test_object_zh":"废气","methodology_zh":"NH3 浓度"},{"_id":"6a83b305af14b9c0e7b20bc0","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NH3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NH3 (z obliczeń)","reference":"PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","norm_bases":["PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja NH3 (z obliczeń) PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r. Gazy odlotowe Emisja NH3 (z obliczen) PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","categories":["environment"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NH3 emission (calculated)","search_en":"Waste gases NH3 emission (calculated) PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","test_object_en":"Waste gases","search_zh":"废气 NH3 排放（由计算得出） PN-ISO 10396:2001 Procedura badawcza PB/LBP/08 wydanie 1 z dnia 19.06.2017 r.","test_object_zh":"废气","methodology_zh":"NH3 排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20bc1","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczenia zawartości metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczenia zawartości metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczenia zawartości metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do oznaczenia zawartosci metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) PN-Z-04030-7:1994","categories":["materials"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for determination of metal content in dust (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V)","search_en":"Waste gases Dust sampling for determination of metal content in dust (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bc2","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja metali w pyle (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) (z obliczen) PN-Z-04030-7:1994","categories":["materials","environment"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of metals in dust (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) (calculated)","search_en":"Waste gases Emission of metals in dust (Al, As, Ba, Cd, Cr, Co, Cu, Sn, Zn, Fe, Mn, Mo, Ni, Pb, Sb, Tl, V) (calculated) PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bc3","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia masowego stężenia WWA","parameters":[],"technique":"Metoda filtracyjno-kondensacyjno-absorpcyjna","techniques":["Metoda filtracyjno-kondensacyjno-absorpcyjna"],"computed":[],"activity":"Pobieranie próbek do oznaczenia masowego stężenia WWA\nMetoda filtracyjno-kondensacyjno-absorpcyjna","reference":"ISO 11338-1:2003","norm_bases":["ISO 11338-1:2003"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia masowego stężenia WWA\nMetoda filtracyjno-kondensacyjno-absorpcyjna ISO 11338-1:2003 Gazy odlotowe Pobieranie probek do oznaczenia masowego stezenia WWA\nMetoda filtracyjno-kondensacyjno-absorpcyjna ISO 11338-1:2003","categories":["other"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the mass concentration of PAH","search_en":"Waste gases Sampling for determination of the mass concentration of PAH ISO 11338-1:2003","test_object_en":"Waste gases","search_zh":"废气 ISO 11338-1:2003","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bc4","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja WWA (z obliczeń)","reference":"ISO 11338-1:2003","norm_bases":["ISO 11338-1:2003"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja WWA (z obliczeń) ISO 11338-1:2003 Gazy odlotowe Emisja WWA (z obliczen) ISO 11338-1:2003","categories":["environment"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PAH emission (calculated)","search_en":"Waste gases PAH emission (calculated) ISO 11338-1:2003","test_object_en":"Waste gases","search_zh":"废气 多环芳烃排放（由计算得出） ISO 11338-1:2003","test_object_zh":"废气","methodology_zh":"多环芳烃排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20bc5","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku, siarkowodoru i kwasu siarkowego.","parameters":[],"technique":"Metoda aspiracyjna.","techniques":["Metoda aspiracyjna."],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku, siarkowodoru i kwasu siarkowego.\nMetoda aspiracyjna.","reference":"PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","norm_bases":["PB/LBP/06 wydanie 6 z dnia 19.07.2021 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku, siarkowodoru i kwasu siarkowego.\nMetoda aspiracyjna. PB/LBP/06 wydanie 6 z dnia 19.07.2021 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku, siarkowodoru i kwasu siarkowego.\nMetoda aspiracyjna. PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","categories":["other"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of ammonia, hydrogen sulfide and sulfuric acid.","search_en":"Waste gases Sampling for determination of the concentration of ammonia, hydrogen sulfide and sulfuric acid. Aspiration method. PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","technique_en":"Aspiration method.","test_object_en":"Waste gases","search_zh":"废气 PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bc6","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja amoniaku, siarkowodoru i kwasu siarkowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku, siarkowodoru i kwasu siarkowego (z obliczeń)","reference":"PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","norm_bases":["PB/LBP/06 wydanie 6 z dnia 19.07.2021 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja amoniaku, siarkowodoru i kwasu siarkowego (z obliczeń) PB/LBP/06 wydanie 6 z dnia 19.07.2021 r. Gazy odlotowe Emisja amoniaku, siarkowodoru i kwasu siarkowego (z obliczen) PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","categories":["environment"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of ammonia, hydrogen sulphide and sulphuric acid (calculated)","search_en":"Waste gases Emission of ammonia, hydrogen sulphide and sulphuric acid (calculated) PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","test_object_en":"Waste gases","search_zh":"废气 PB/LBP/06 wydanie 6 z dnia 19.07.2021 r.","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bc7","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężeń masowych: Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężeń masowych: Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężeń masowych: Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczenia stezen masowych: Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn PN-EN 14385:2025-05","categories":["other"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the mass concentrations: Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn","search_en":"Waste gases Sampling for determination of the mass concentrations: Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn PN-EN 14385:2025-05","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bc8","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja (Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja (Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn) (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja (Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn) (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja (Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn) (z obliczen) PN-EN 14385:2025-05","categories":["environment"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of (Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn) (calculated)","search_en":"Waste gases Emission of (Ag, Al, B, Ba, Bi, Ca, Fe, Mg, Mo, Se, Sn, Ti, Zn) (calculated) PN-EN 14385:2025-05","test_object_en":"Waste gases","search_zh":"废气 PN-EN 14385:2025-05","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bc9","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia NH3","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia NH3","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia NH3 PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia NH3 PN-EN ISO 21877:2020-03","categories":["other"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of NH3 concentration","search_en":"Waste gases Sampling for the determination of NH3 concentration PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 PN-EN ISO 21877:2020-03","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bca","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NH3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NH3 (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja NH3 (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja NH3 (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NH3 emission (calculated)","search_en":"Waste gases NH3 emission (calculated) PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 NH3 排放（由计算得出） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"NH3 排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20bcb","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia H2SO4, SO3","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia H2SO4, SO3","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia H2SO4, SO3 VDI 2462-2:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia H2SO4, SO3 VDI 2462-2:2011","categories":["other"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of H2SO4, SO3","search_en":"Waste gases Sampling for determination of the concentration of H2SO4, SO3 VDI 2462-2:2011","test_object_en":"Waste gases","search_zh":"废气 VDI 2462-2:2011","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bcc","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie H2SO4","parameters":[{"name":"Zakres","range":"(1,0 - 50,0) mg/m3"},{"name":"Stężenie SO3"},{"name":"Zakres","range":"(1,1 - 50,0) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie H2SO4\nZakres:\nZakres (1,0 - 50,0) mg/m3\nStężenie SO3\nZakres (1,1 - 50,0) mg/m3\nMetoda toronowa","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie H2SO4\nZakres:\nZakres (1,0 - 50,0) mg/m3\nStężenie SO3\nZakres (1,1 - 50,0) mg/m3\nMetoda toronowa VDI 2462-2:2011 Gazy odlotowe Stezenie H2SO4\nZakres:\nZakres (1,0 - 50,0) mg/m3\nStezenie SO3\nZakres (1,1 - 50,0) mg/m3\nMetoda toronowa VDI 2462-2:2011","categories":["other"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"H2SO4 concentration","parameters_en":[{"name":"Range","range":"(1,0 - 50,0) mg/m3"},{"name":"SO3 concentration"},{"name":"Range","range":"(1,1 - 50,0) mg/m3"}],"search_en":"Waste gases H2SO4 concentration Thoron method Range SO3 concentration Range VDI 2462-2:2011","technique_en":"Thoron method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 50,0) mg/m3"},{"name":"Stężenie SO3"},{"name":"范围","range":"(1,1 - 50,0) mg/m3"}],"search_zh":"废气 钍射气法 范围 范围 VDI 2462-2:2011","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a83b305af14b9c0e7b20bcd","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO3, H2SO4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO3, H2SO4 (z obliczeń)","reference":"VDI 2462-2:2011","norm_bases":["VDI 2462-2:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja SO3, H2SO4 (z obliczeń) VDI 2462-2:2011 Gazy odlotowe Emisja SO3, H2SO4 (z obliczen) VDI 2462-2:2011","categories":["environment"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of SO3, H2SO4 (calculated)","search_en":"Waste gases Emission of SO3, H2SO4 (calculated) VDI 2462-2:2011","test_object_en":"Waste gases","search_zh":"废气 VDI 2462-2:2011","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bce","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia bromowanych związków opóźniających zapłon","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczenia bromowanych związków opóźniających zapłon","reference":"PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","norm_bases":["PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia bromowanych związków opóźniających zapłon PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r. Gazy odlotowe Pobieranie probek do oznaczenia bromowanych zwiazkow opozniajacych zaplon PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","categories":["other"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of brominated flame retardants","search_en":"Waste gases Sampling for determination of brominated flame retardants PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","test_object_en":"Waste gases","search_zh":"废气 PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bcf","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja bromowanych związków opóźniających zapłon (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja bromowanych związków opóźniających zapłon (z obliczeń)","reference":"PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","norm_bases":["PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja bromowanych związków opóźniających zapłon (z obliczeń) PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r. Gazy odlotowe Emisja bromowanych zwiazkow opozniajacych zaplon (z obliczen) PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","categories":["environment"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of brominated flame retardants (calculated)","search_en":"Waste gases Emission of brominated flame retardants (calculated) PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","test_object_en":"Waste gases","search_zh":"废气 溴系阻燃剂排放（由计算得出） PN-EN 1948-1:2006 PB/LBP/09, wydanie 1 z dnia 01.06.2023 r.","test_object_zh":"废气","methodology_zh":"溴系阻燃剂排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20bd0","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania frakcji pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania frakcji pyłu","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania frakcji pyłu PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r. Gazy odlotowe Pobieranie probek do oznaczania frakcji pylu PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","categories":["other"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the dust fraction","search_en":"Waste gases Sampling for determination of the dust fraction PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","test_object_en":"Waste gases","search_zh":"废气 用于测定粉尘分级的采样 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","test_object_zh":"废气","methodology_zh":"用于测定粉尘分级的采样"},{"_id":"6a83b305af14b9c0e7b20bd1","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r. Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","categories":["environment"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Procedura badawcza PB/LBP/11 wydanie 1 z dnia 16.08.2024 r.","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a83b305af14b9c0e7b20bd2","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie podtlenku azotu","parameters":[{"name":"Zakres","range":"(1,0 - 200) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie podtlenku azotu\nZakres (1,0 - 200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 21258:2010","norm_bases":["PN-EN 21258:2010"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie podtlenku azotu\nZakres (1,0 - 200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 21258:2010 Gazy odlotowe Stezenie podtlenku azotu\nZakres (1,0 - 200) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 21258:2010","categories":["other"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrous oxide concentration","parameters_en":[{"name":"Range","range":"(1,0 - 200) mg/m3"}],"search_en":"Waste gases Nitrous oxide concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 21258:2010","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 200) mg/m3"}],"search_zh":"废气 一氧化二氮浓度 非分散红外光谱法（NDIR） 范围 PN-EN 21258:2010","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"一氧化二氮浓度"},{"_id":"6a83b305af14b9c0e7b20bd3","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja N2O (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja N2O (z obliczeń)","reference":"PN-EN 21258:2010","norm_bases":["PN-EN 21258:2010"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja N2O (z obliczeń) PN-EN 21258:2010 Gazy odlotowe Emisja N2O (z obliczen) PN-EN 21258:2010","categories":["environment"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"N2O emission (calculated)","search_en":"Waste gases N2O emission (calculated) PN-EN 21258:2010","test_object_en":"Waste gases","search_zh":"废气 N2O 排放（由计算得出） PN-EN 21258:2010","test_object_zh":"废气","methodology_zh":"N2O 排放（由计算得出）"},{"_id":"6a83b305af14b9c0e7b20bd4","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie metanu","parameters":[{"name":"Zakres","range":"(1,0 - 50) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie metanu\nZakres (1,0 - 50) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN ISO 25140:2011","norm_bases":["PN-EN ISO 25140:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie metanu\nZakres (1,0 - 50) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN ISO 25140:2011 Gazy odlotowe Stezenie metanu\nZakres (1,0 - 50) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN ISO 25140:2011","categories":["other"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methane concentration","parameters_en":[{"name":"Range","range":"(1,0 - 50) mg/m3"}],"search_en":"Waste gases Methane concentration Continuous flame ionization detection method (FID) Range PN-EN ISO 25140:2011","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(1,0 - 50) mg/m3"}],"search_zh":"废气 甲烷浓度 连续火焰离子化检测法（FID） 范围 PN-EN ISO 25140:2011","test_object_zh":"废气","technique_zh":"连续火焰离子化检测法（FID）","methodology_zh":"甲烷浓度"},{"_id":"6a83b305af14b9c0e7b20bd5","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CH4 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CH4 (z obliczeń)","reference":"PN-EN ISO 25140:2011","norm_bases":["PN-EN ISO 25140:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja CH4 (z obliczeń) PN-EN ISO 25140:2011 Gazy odlotowe Emisja CH4 (z obliczen) PN-EN ISO 25140:2011","categories":["environment"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CH4 emission (calculated)","search_en":"Waste gases CH4 emission (calculated) PN-EN ISO 25140:2011","test_object_en":"Waste gases","search_zh":"废气 PN-EN ISO 25140:2011","test_object_zh":"废气"},{"_id":"6a83b305af14b9c0e7b20bd6","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","methodology":"Skuteczność odpylania dla stężeń pyłu","parameters":[{"name":"Zakres","range":"(0,00064 - 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Skuteczność odpylania dla stężeń pyłu\nZakres (0,00064 - 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A | PN-EN 13284-1:2018-02","norm_bases":["PN-Z-04030-7:1994","PN-87/M-34129 Metoda A","PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania dla stężeń pyłu\nZakres (0,00064 - 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A | PN-EN 13284-1:2018-02 Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania dla stezen pylu\nZakres (0,00064 - 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A | PN-EN 13284-1:2018-02","categories":["other"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dedusting efficiency for dust concentrations","parameters_en":[{"name":"Range","range":"(0,00064 - 100) g/m3"}],"search_en":"Waste gas dedusting equipment Dedusting efficiency for dust concentrations Gravimetric method Range PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A | PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gas dedusting equipment","parameters_zh":[{"name":"范围","range":"(0,00064 - 100) g/m3"}],"search_zh":"废气除尘设备 重量法 范围 PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A | PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气除尘设备"},{"_id":"6a83b305af14b9c0e7b20bd7","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Gazy składowiskowe","methodology":"Stężenia gazów","parameters":[{"name":"CH4","range":"(0,5 - 40,0) %"},{"name":"CO2","range":"(0,5 - 20,0) %"},{"name":"O2"},{"name":"Zakres","range":"(2,0 - 21,0) %"},{"name":"Prędkość przepływu"},{"name":"Zakres","range":"(0,5 - 10,0) m/s"}],"technique":"Metoda detekcji w podczerwieni (IR); Metoda elektrochemiczna; Metoda anemometryczna","techniques":["Metoda detekcji w podczerwieni (IR)","Metoda elektrochemiczna","Metoda anemometryczna"],"computed":[],"activity":"Stężenia gazów\nZakres:\nCH4 (0,5 - 40,0) %\nCO2 (0,5 - 20,0) %\nO2\nZakres (2,0 - 21,0) %\nPrędkość przepływu\nZakres (0,5 - 10,0) m/s\nMetoda detekcji w podczerwieni (IR); Metoda elektrochemiczna; Metoda anemometryczna","reference":"PB/LBP/01 wydanie 9 z dnia 02.05.2023 r.","norm_bases":["PB/LBP/01 wydanie 9 z dnia 02.05.2023 r."],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy składowiskowe Stężenia gazów\nZakres:\nCH4 (0,5 - 40,0) %\nCO2 (0,5 - 20,0) %\nO2\nZakres (2,0 - 21,0) %\nPrędkość przepływu\nZakres (0,5 - 10,0) m/s\nMetoda detekcji w podczerwieni (IR); Metoda elektrochemiczna; Metoda anemometryczna PB/LBP/01 wydanie 9 z dnia 02.05.2023 r. Gazy skladowiskowe Stezenia gazow\nZakres:\nCH4 (0,5 - 40,0) %\nCO2 (0,5 - 20,0) %\nO2\nZakres (2,0 - 21,0) %\nPredkosc przeplywu\nZakres (0,5 - 10,0) m/s\nMetoda detekcji w podczerwieni (IR); Metoda elektrochemiczna; Metoda anemometryczna PB/LBP/01 wydanie 9 z dnia 02.05.2023 r.","categories":["other"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas concentrations","parameters_en":[{"name":"CH4","range":"(0,5 - 40,0) %"},{"name":"CO2","range":"(0,5 - 20,0) %"},{"name":"O2"},{"name":"Range","range":"(2,0 - 21,0) %"},{"name":"Flow velocity"},{"name":"Range","range":"(0,5 - 10,0) m/s"}],"search_en":"Landfill gases Gas concentrations Infrared detection method (IR); Electrochemical method; Anemometric method CH4 CO2 O2 Range Flow velocity Range PB/LBP/01 wydanie 9 z dnia 02.05.2023 r.","technique_en":"Infrared detection method (IR); Electrochemical method; Anemometric method","test_object_en":"Landfill gases","parameters_zh":[{"name":"CH4","range":"(0,5 - 40,0) %"},{"name":"CO2","range":"(0,5 - 20,0) %"},{"name":"O2"},{"name":"范围","range":"(2,0 - 21,0) %"},{"name":"流速"},{"name":"范围","range":"(0,5 - 10,0) m/s"}],"search_zh":"填埋场气体 CO2 O2 范围 流速 范围 PB/LBP/01 wydanie 9 z dnia 02.05.2023 r.","test_object_zh":"填埋场气体"},{"_id":"6a83b305af14b9c0e7b20bd8","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze - gazy emitowane do powietrza","methodology":"Pobieranie próbek do badań metodą olfaktometrii dynamicznej ze źródeł punktowych","parameters":[],"technique":"Metoda płuca","techniques":["Metoda płuca"],"computed":[],"activity":"Pobieranie próbek do badań metodą olfaktometrii dynamicznej ze źródeł punktowych\nMetoda płuca","reference":"PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011","norm_bases":["PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze - gazy emitowane do powietrza Pobieranie próbek do badań metodą olfaktometrii dynamicznej ze źródeł punktowych\nMetoda płuca PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011 Srodowisko ogolne - powietrze - gazy emitowane do powietrza Pobieranie probek do badan metoda olfaktometrii dynamicznej ze zrodel punktowych\nMetoda pluca PN-EN 13725:2022-07 z wylaczeniem pkt. 9.1.4.3 VDI 3880:2011","categories":["environment"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for testing by dynamic olfactometry from point sources","search_en":"General environment - air - gases emitted into the air Sampling for testing by dynamic olfactometry from point sources Metoda płuca PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011","technique_en":"Metoda płuca","test_object_en":"General environment - air - gases emitted into the air","search_zh":"一般环境 － 空气 － 排入大气的气体 肺式法 PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011","test_object_zh":"一般环境 － 空气 － 排入大气的气体","technique_zh":"肺式法"},{"_id":"6a83b305af14b9c0e7b20bd9","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze - gazy emitowane do powietrza","methodology":"Pobieranie próbek do badań metodą olfaktometrii dynamicznej ze źródeł powierzchniowych aktywnych","parameters":[],"technique":"Metoda płuca","techniques":["Metoda płuca"],"computed":[],"activity":"Pobieranie próbek do badań metodą olfaktometrii dynamicznej ze źródeł powierzchniowych aktywnych\nMetoda płuca","reference":"PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011","norm_bases":["PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze - gazy emitowane do powietrza Pobieranie próbek do badań metodą olfaktometrii dynamicznej ze źródeł powierzchniowych aktywnych\nMetoda płuca PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011 Srodowisko ogolne - powietrze - gazy emitowane do powietrza Pobieranie probek do badan metoda olfaktometrii dynamicznej ze zrodel powierzchniowych aktywnych\nMetoda pluca PN-EN 13725:2022-07 z wylaczeniem pkt. 9.1.4.3 VDI 3880:2011","categories":["environment"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for testing by dynamic olfactometry from active area sources","search_en":"General environment - air - gases emitted into the air Sampling for testing by dynamic olfactometry from active area sources Metoda płuca PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011","technique_en":"Metoda płuca","test_object_en":"General environment - air - gases emitted into the air","search_zh":"一般环境 － 空气 － 排入大气的气体 肺式法 PN-EN 13725:2022-07 z wyłączeniem pkt. 9.1.4.3 VDI 3880:2011","test_object_zh":"一般环境 － 空气 － 排入大气的气体","technique_zh":"肺式法"},{"_id":"6a83b305af14b9c0e7b20bda","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze - gazy emitowane do powietrza","methodology":"Strumień zapachowy ze źródeł punktowych i powierzchniowych aktywnych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Strumień zapachowy ze źródeł punktowych i powierzchniowych aktywnych (z obliczeń)","reference":"PN-EN 13725:2022-07","norm_bases":["PN-EN 13725:2022-07"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze - gazy emitowane do powietrza Strumień zapachowy ze źródeł punktowych i powierzchniowych aktywnych (z obliczeń) PN-EN 13725:2022-07 Srodowisko ogolne - powietrze - gazy emitowane do powietrza Strumien zapachowy ze zrodel punktowych i powierzchniowych aktywnych (z obliczen) PN-EN 13725:2022-07","categories":["environment"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour emission rate from point and active area sources (calculated)","search_en":"General environment - air - gases emitted into the air Odour emission rate from point and active area sources (calculated) PN-EN 13725:2022-07","test_object_en":"General environment - air - gases emitted into the air","search_zh":"一般环境 － 空气 － 排入大气的气体 PN-EN 13725:2022-07","test_object_zh":"一般环境 － 空气 － 排入大气的气体"},{"_id":"6a83b305af14b9c0e7b20bdb","lab_id":"69ad52a3de79e566650fb434","country":"PL","accr_number":"AB 833","accr_body":"PCA","test_object":"Środowisko ogólne - powietrze - gazy emitowane do powietrza","methodology":"Skuteczność dezodoryzacji (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność dezodoryzacji (z obliczeń)","reference":"PN-EN 13725:2022-07","norm_bases":["PN-EN 13725:2022-07"],"lab_section":"Laboratorium Badania Powietrza","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - powietrze - gazy emitowane do powietrza Skuteczność dezodoryzacji (z obliczeń) PN-EN 13725:2022-07 Srodowisko ogolne - powietrze - gazy emitowane do powietrza Skutecznosc dezodoryzacji (z obliczen) PN-EN 13725:2022-07","categories":["environment"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Deodorisation efficiency (calculated)","search_en":"General environment - air - gases emitted into the air Deodorisation efficiency (calculated) PN-EN 13725:2022-07","test_object_en":"General environment - air - gases emitted into the air","search_zh":"一般环境 － 空气 － 排入大气的气体 PN-EN 13725:2022-07","test_object_zh":"一般环境 － 空气 － 排入大气的气体"}],"has_pdf":true}