{"lab":{"_id":"69ad52a3de79e566650fb430","accr_number":"AB 830","country":"PL","accr_body":"PCA","address":"LABORATORIUM PROCESU, Chorula, ul. Cementowa 1, 47-316 Górażdże","categories":["petro","construction","materials"],"city":"Górażdże","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"GÓRAŻDŻE CEMENT S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_830.pdf"],"scope_summary":"","search_text":"górażdże cement s.a. laboratorium procesu, chorula, ul. cementowa 1, 47-316 górażdże materials construction electronics other petro pharma","status":"active","updated_at":"2026-03-08T14:51:43.076Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:43.076Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20830,podmiot.html","fields_of_testing":[{"codes":"C/5","pl":"Badania chemiczne materiałów budowlanych","en":"Chemical tests of buildings materials"},{"codes":"C/10","pl":"Badania chemiczne paliw stałych","en":"Chemical tests of solid fuels"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów budowlanych","en":"Tests of physical properties of buildings materials"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"}],"issue":{"no":"21","date":"10.08.2023"},"parse_date":"2026-07-20T07:09:51.690Z","parse_source":"script-pdfplumber","map_coord":[50.532901,17.973137],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":19,"construction":5,"materials":5},"category_scores":{"petro":12.45,"construction":0.86,"materials":0.86},"has_zh":true},"methods":[{"_id":"6a5dc9bff1c10c8ce825ef13","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Materiały budowlane: klinkier portlandzki, cement, kamień wapienny","test_object_en":"Building materials: Portland clinker, cement, limestone","methodology":"Zawartość SiO2, Al2O3, Fe2O3, CaO, MgO, Na2O, K2O","methodology_en":"Content of SiO2, Al2O3, Fe2O3, CaO, MgO, Na2O, K2O","parameters":[{"name":"SiO2","range":"(18,00 – 35,00) %"},{"name":"Al2O3","range":"(4,00 – 11,00) %"},{"name":"Fe2O3","range":"(0,50 – 4,50) %"},{"name":"CaO","range":"(40,00 – 71,00) %"},{"name":"MgO","range":"(0,50 – 3,00) %"},{"name":"Na2O","range":"(0,10 – 0,80) %"},{"name":"K2O","range":"(0,10 – 2,00) %"}],"parameters_en":[{"name":"SiO2","range":"(18,00 – 35,00) %"},{"name":"Al2O3","range":"(4,00 – 11,00) %"},{"name":"Fe2O3","range":"(0,50 – 4,50) %"},{"name":"CaO","range":"(40,00 – 71,00) %"},{"name":"MgO","range":"(0,50 – 3,00) %"},{"name":"Na2O","range":"(0,10 – 0,80) %"},{"name":"K2O","range":"(0,10 – 2,00) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość SiO2, Al2O3, Fe2O3, CaO, MgO, Na2O, K2O\nZakres:\nSiO2 (18,00 – 35,00) %\nAl2O3 (4,00 – 11,00) %\nFe2O3 (0,50 – 4,50) %\nCaO (40,00 – 71,00) %\nMgO (0,50 – 3,00) %\nNa2O (0,10 – 0,80) %\nK2O (0,10 – 2,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF)","reference":"PN-EN 196-2:2013-11","norm_bases":["PN-EN 196-2:2013-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: klinkier portlandzki, cement, kamień wapienny Zawartość SiO2, Al2O3, Fe2O3, CaO, MgO, Na2O, K2O\nZakres:\nSiO2 (18,00 – 35,00) %\nAl2O3 (4,00 – 11,00) %\nFe2O3 (0,50 – 4,50) %\nCaO (40,00 – 71,00) %\nMgO (0,50 – 3,00) %\nNa2O (0,10 – 0,80) %\nK2O (0,10 – 2,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją fali (WD-XRF) PN-EN 196-2:2013-11 Materialy budowlane: klinkier portlandzki, cement, kamien wapienny Zawartosc SiO2, Al2O3, Fe2O3, CaO, MgO, Na2O, K2O\nZakres:\nSiO2 (18,00 – 35,00) %\nAl2O3 (4,00 – 11,00) %\nFe2O3 (0,50 – 4,50) %\nCaO (40,00 – 71,00) %\nMgO (0,50 – 3,00) %\nNa2O (0,10 – 0,80) %\nK2O (0,10 – 2,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja fali (WD-XRF) PN-EN 196-2:2013-11","categories":["construction","materials"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: Portland clinker, cement, limestone Content of SiO2, Al2O3, Fe2O3, CaO, MgO, Na2O, K2O Wavelength dispersive X-ray fluorescence spectrometry (WD-XRF) SiO2 Al2O3 Fe2O3 CaO MgO Na2O K2O PN-EN 196-2:2013-11","parameters_zh":[{"name":"SiO2","range":"(18,00 – 35,00) %"},{"name":"Al2O3","range":"(4,00 – 11,00) %"},{"name":"Fe2O3","range":"(0,50 – 4,50) %"},{"name":"CaO","range":"(40,00 – 71,00) %"},{"name":"MgO","range":"(0,50 – 3,00) %"},{"name":"Na2O","range":"(0,10 – 0,80) %"},{"name":"K2O","range":"(0,10 – 2,00) %"}],"search_zh":"波长色散 X 射线荧光光谱法（WD-XRF） SiO2 Al2O3 Fe2O3 CaO MgO Na2O K2O PN-EN 196-2:2013-11","technique_zh":"波长色散 X 射线荧光光谱法（WD-XRF）"},{"_id":"6a5dc9bff1c10c8ce825ef14","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (przemijającej)","methodology_en":"First-stage (free) moisture content","parameters":[{"name":"Zakres","range":"(0,1 – 50,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 50,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (0,1 – 50,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (przemijającej)\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (przemijajacej)\nZakres (0,1 – 50,0) %\nMetoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal First-stage (free) moisture content Gravimetric method Range PN-ISO 589:2006","parameters_zh":[{"name":"范围","range":"(0,1 – 50,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a5dc9bff1c10c8ce825ef15","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,1 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 30,0) %\nMetoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 30,0) %\nMetoda wagowa PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 30,0) %\nMetoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-ISO 11722:2009","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 30,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bff1c10c8ce825ef16","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrzno-suchym)","methodology_en":"Second-stage moisture content (moisture in air-dried coal)","parameters":[{"name":"Zakres","range":"(0,1 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrzno-suchym)\nZakres (0,1 – 30,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1","norm_bases":["PN-ISO 589:2006 Metoda A1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci w węglu powietrzno-suchym)\nZakres (0,1 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci w weglu powietrzno-suchym)\nZakres (0,1 – 30,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1","categories":["petro"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Second-stage moisture content (moisture in air-dried coal) Gravimetric method Range PN-ISO 589:2006 Metoda A1","parameters_zh":[{"name":"范围","range":"(0,1 – 30,0) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-ISO 589:2006 Metoda A1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bff1c10c8ce825ef17","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5dc9bff1c10c8ce825ef18","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(10000 – 36000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(10000 – 36000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (10000 – 36000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (10000 – 36000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (10000 – 36000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-ISO 1928:2020-05","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10000 – 36000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bff1c10c8ce825ef19","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(20,0 – 96,0) %"}],"parameters_en":[{"name":"Range","range":"(20,0 – 96,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (20,0 – 96,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (20,0 – 96,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (20,0 – 96,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(20,0 – 96,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bff1c10c8ce825ef1a","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(2,00 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(2,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (2,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (2,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (2,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","parameters_zh":[{"name":"范围","range":"(2,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a5dc9bff1c10c8ce825ef1b","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,1 – 90,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,1 – 90,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (0,1 – 90,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (0,1 – 90,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 90,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bff1c10c8ce825ef1c","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,01 – 3,00) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,01 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,01 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,01 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,01 – 3,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bff1c10c8ce825ef1d","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,90 – 4,00) %"}],"parameters_en":[{"name":"Range","range":"(0,90 – 4,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,90 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,90 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,90 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-G-04571:1998","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range PN-G-04571:1998","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,90 – 4,00) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 PN-G-04571:1998","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a5dc9bff1c10c8ce825ef1e","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,5 – 22,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 22,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 22,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 22,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 22,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 21660-3:2021-08","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 22,0) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef1f","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(0,5 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (0,5 – 40,0) %\nMetoda wagowa","reference":"CEN/TS 15414-1:2010 CEN/TS 15414-2:2010","norm_bases":["CEN/TS 15414-1:2010 CEN/TS 15414-2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość wilgoci całkowitej\nZakres (0,5 – 40,0) %\nMetoda wagowa CEN/TS 15414-1:2010 CEN/TS 15414-2:2010 Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc wilgoci calkowitej\nZakres (0,5 – 40,0) %\nMetoda wagowa CEN/TS 15414-1:2010 CEN/TS 15414-2:2010","categories":["petro"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Total moisture content Gravimetric method Range CEN/TS 15414-1:2010 CEN/TS 15414-2:2010","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 40,0) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 全水分含量 重量法 范围 CEN/TS 15414-1:2010 CEN/TS 15414-2:2010","technique_zh":"重量法","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef20","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(10000 – 36000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(10000 – 36000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (10000 – 36000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Ciepło spalania\nZakres:\nZakres (10000 – 36000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale: paliwa wtorne – paliwa alternatywne Cieplo spalania\nZakres:\nZakres (10000 – 36000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["petro"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-EN ISO 21654:2021-12","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10000 – 36000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 高位发热量 量热法 范围 低位发热量（计算值） PN-EN ISO 21654:2021-12","technique_zh":"量热法","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef21","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(20,0 – 90,0) %"}],"parameters_en":[{"name":"Range","range":"(20,0 – 90,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (20,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość węgla całkowitego\nZakres (20,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc wegla calkowitego\nZakres (20,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Total carbon content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(20,0 – 90,0) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef22","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(0,5 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (0,5 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość popiołu\nZakres (0,5 – 40,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc popiolu\nZakres (0,5 – 40,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Ash content Gravimetric method Range PN-EN ISO 21656:2021-08","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 40,0) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 灰分含量 重量法 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef23","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość chloru","methodology_en":"Chlorine content","parameters":[{"name":"Zakres","range":"(0,05 – 3,00) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 3,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chloru\nZakres (0,05 – 3,00) %\nMetoda miareczkowa","reference":"PB-07 wydanie 4 z dnia 23.02.2023 r.","norm_bases":["PB-07 wydanie 4 z dnia 23.02.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość chloru\nZakres (0,05 – 3,00) %\nMetoda miareczkowa PB-07 wydanie 4 z dnia 23.02.2023 r. Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc chloru\nZakres (0,05 – 3,00) %\nMetoda miareczkowa PB-07 wydanie 4 z dnia 23.02.2023 r.","categories":["petro"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Chlorine content Titrimetric method Range PB-07 wydanie 4 z dnia 23.02.2023 r.","parameters_zh":[{"name":"范围","range":"(0,05 – 3,00) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 氯含量 滴定法 范围 PB-07 wydanie 4 z dnia 23.02.2023 r.","technique_zh":"滴定法","methodology_zh":"氯含量","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef24","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,10 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość siarki całkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc siarki calkowitej\nZakres (0,10 – 2,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 2,00) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef25","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(2,00 – 10,00) %"}],"parameters_en":[{"name":"Range","range":"(2,00 – 10,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (2,00 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość wodoru\nZakres (2,00 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc wodoru\nZakres (2,00 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 21663:2021-06","parameters_zh":[{"name":"范围","range":"(2,00 – 10,00) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef26","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Paliwa stałe: paliwa wtórne – paliwa alternatywne","test_object_en":"Solid fuels: secondary fuels – alternative fuels","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,90 – 5,60) %"}],"parameters_en":[{"name":"Range","range":"(0,90 – 5,60) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,90 – 5,60) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: paliwa wtórne – paliwa alternatywne Zawartość azotu\nZakres (0,90 – 5,60) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 21663:2021-06 Paliwa stale: paliwa wtorne – paliwa alternatywne Zawartosc azotu\nZakres (0,90 – 5,60) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 21663:2021-06","categories":["petro"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: secondary fuels – alternative fuels Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 21663:2021-06","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,90 – 5,60) %"}],"search_zh":"固体燃料：再生燃料 － 替代燃料 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧总碳检测法","test_object_zh":"固体燃料：再生燃料 － 替代燃料"},{"_id":"6a5dc9bff1c10c8ce825ef27","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Materiały budowlane: gips, reagips","test_object_en":"Building materials: gypsum, FGD gypsum","methodology":"Zawartość wilgoci","methodology_en":"Moisture content","parameters":[{"name":"Zakres","range":"(0,1 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci\nZakres (0,1 – 30,0) %\nMetoda wagowa","reference":"PB-05 wydanie 3 z dnia 21.02.2019 r.","norm_bases":["PB-05 wydanie 3 z dnia 21.02.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: gips, reagips Zawartość wilgoci\nZakres (0,1 – 30,0) %\nMetoda wagowa PB-05 wydanie 3 z dnia 21.02.2019 r. Materialy budowlane: gips, reagips Zawartosc wilgoci\nZakres (0,1 – 30,0) %\nMetoda wagowa PB-05 wydanie 3 z dnia 21.02.2019 r.","categories":["materials","construction"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: gypsum, FGD gypsum Moisture content Gravimetric method Range PB-05 wydanie 3 z dnia 21.02.2019 r.","parameters_zh":[{"name":"范围","range":"(0,1 – 30,0) %"}],"search_zh":"水分含量 重量法 范围 PB-05 wydanie 3 z dnia 21.02.2019 r.","technique_zh":"重量法","methodology_zh":"水分含量"},{"_id":"6a5dc9bff1c10c8ce825ef28","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Materiały budowlane: surowce do produkcji klinkieru, surowce do produkcji cementu","test_object_en":"Building materials: raw materials for clinker production, raw materials for cement production","methodology":"Zawartość wilgoci","methodology_en":"Moisture content","parameters":[{"name":"Zakres","range":"(0,1 – 55,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 55,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci\nZakres (0,1 – 55,0) %\nMetoda wagowa","reference":"BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","norm_bases":["BN-83/6731-02","PB-06 wydanie 6 z dnia 21.02.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: surowce do produkcji klinkieru, surowce do produkcji cementu Zawartość wilgoci\nZakres (0,1 – 55,0) %\nMetoda wagowa BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r. Materialy budowlane: surowce do produkcji klinkieru, surowce do produkcji cementu Zawartosc wilgoci\nZakres (0,1 – 55,0) %\nMetoda wagowa BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","categories":["construction","materials"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: raw materials for clinker production, raw materials for cement production Moisture content Gravimetric method Range BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","parameters_zh":[{"name":"范围","range":"(0,1 – 55,0) %"}],"search_zh":"水分含量 重量法 范围 BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","technique_zh":"重量法","methodology_zh":"水分含量"},{"_id":"6a5dc9bff1c10c8ce825ef29","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Materiały budowlane: popioły, piaski ze złóż fluidalnych","test_object_en":"Building materials: ashes, sands from fluidized beds","methodology":"Zawartość wilgoci","methodology_en":"Moisture content","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) %"}],"parameters_en":[{"name":"Range","range":"(0,05 – 5,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci\nZakres (0,05 – 5,00) %\nMetoda wagowa","reference":"BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","norm_bases":["BN-83/6731-02","PB-06 wydanie 6 z dnia 21.02.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: popioły, piaski ze złóż fluidalnych Zawartość wilgoci\nZakres (0,05 – 5,00) %\nMetoda wagowa BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r. Materialy budowlane: popioly, piaski ze zloz fluidalnych Zawartosc wilgoci\nZakres (0,05 – 5,00) %\nMetoda wagowa BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","categories":["materials","construction"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: ashes, sands from fluidized beds Moisture content Gravimetric method Range BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","parameters_zh":[{"name":"范围","range":"(0,05 – 5,00) %"}],"search_zh":"水分含量 重量法 范围 BN-83/6731-02 | PB-06 wydanie 6 z dnia 21.02.2019 r.","technique_zh":"重量法","methodology_zh":"水分含量"},{"_id":"6a5dc9bff1c10c8ce825ef2a","lab_id":"69ad52a3de79e566650fb430","country":"PL","accr_number":"AB 830","accr_body":"PCA","test_object":"Materiały budowlane: surowce węglanowe","test_object_en":"Building materials: carbonate raw materials","methodology":"Całkowita zawartość węgla organicznego (TOC)","methodology_en":"Total organic carbon content (TOC)","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) %"}],"parameters_en":[{"name":"Range","range":"(0,01 – 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Całkowita zawartość węgla organicznego (TOC)\nZakres (0,01 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 13639:2017-11","norm_bases":["PN-EN 13639:2017-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: surowce węglanowe Całkowita zawartość węgla organicznego (TOC)\nZakres (0,01 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 13639:2017-11 Materialy budowlane: surowce weglanowe Calkowita zawartosc wegla organicznego (TOC)\nZakres (0,01 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 13639:2017-11","categories":["materials","construction"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: carbonate raw materials Total organic carbon content (TOC) High-temperature combustion with IR detection Range PN-EN 13639:2017-11","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) %"}],"search_zh":"高温燃烧红外检测法 范围 PN-EN 13639:2017-11","technique_zh":"高温燃烧红外检测法"}],"has_pdf":true}