{"lab":{"_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","address":"W GORZOWIE WIELKOPOLSKIM, ul. Św. Jerzego 26, 66-400 Gorzów Wlkp.","categories":["environment","materials"],"city":"Gorzów Wlkp","imported_at":"2026-03-08T10:42:43.265Z","methods_count":54,"name":"OKRĘGOWA STACJA CHEMICZNO-ROLNICZA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_827.pdf"],"scope_summary":"","search_text":"okręgowa stacja chemiczno-rolnicza w gorzowie wielkopolskim, ul. św. jerzego 26, 66-400 gorzów wlkp. other water food","status":"active","updated_at":"2026-03-08T14:51:42.873Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:25:27.115Z","email_confidence":"high","email_mx":true,"email_source":"https://www.oschr-gorzow.pl/kontakt/","fields_of_testing":[{"codes":"C/31/P","pl":"Badania chemiczne i pobieranie próbek gleb","en":"Chemical tests and sampling of soil"},{"codes":"C/1; C/43; C/44","pl":"Badania chemiczne produktów rolnych, nawozów, środków wspomagających uprawę roślin","en":"Chemical tests of agricultural products, fertilizers, plant conditioners"},{"codes":"N/31/P","pl":"Badania właściwości fizycznych i pobieranie próbek gleb","en":"Tests of physical properties and samplinf of soil"},{"codes":"N/43; N/44","pl":"Badania właściwości fizycznych nawozów, środków wspomagających uprawę roślin","en":"Tests of physical properties of fertilizers, plant conditioners"}],"issue":{"no":"22","date":"22.07.2026"},"parse_date":"2026-08-18T01:25:27.115Z","parse_source":"agent-claude-code","map_coord":[52.727604,15.244046],"map_geo":"nominatim-street","lab_locations":[{"name":"Dział Laboratoryjny","address":"ul. Św. Jerzego 26, 66-400 Gorzów Wlkp.","city":"Gorzów Wlkp.","postal":"66-400"},{"name":"Dział Agrochemicznej Obsługi Rolnictwa","address":"ul. Św. Jerzego 26, 66-400 Gorzów Wlkp.","city":"Gorzów Wlkp.","postal":"66-400"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/af7c21955014281ff12b4204ae1a8398/AB%20827.pdf","has_en":true,"category_counts":{"environment":32,"other":16,"materials":5,"water":2},"category_scores":{"environment":18.62,"other":4.65,"materials":0.45,"water":0.07},"has_zh":true,"lab_locations_zh":[{"name":"实验室部","address":"ul. Św. Jerzego 26, 66-400 Gorzów Wlkp.","city":"Gorzów Wlkp.","postal":"66-400"},{"name":"Dział Agrochemicznej Obsługi Rolnictwa","address":"ul. Św. Jerzego 26, 66-400 Gorzów Wlkp.","city":"Gorzów Wlkp.","postal":"66-400"}]},"methods":[{"_id":"6a83b487af14b9c0e7b20c99","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość fosforu przyswajalnego","parameters":[{"name":"Zakres","range":"(1,5 – 50,0) mg/100 g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (1,5 – 50,0) mg/100 g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość fosforu przyswajalnego\nZakres (1,5 – 50,0) mg/100 g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba mineralna Zawartosc fosforu przyswajalnego\nZakres (1,5 – 50,0) mg/100 g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(1,5 – 50,0) mg/100 g P2O5"}],"search_en":"Mineral soil Available phosphorus content Spectrophotometric method Laboratory Department Range PN-R-04023:1996","technique_en":"Spectrophotometric method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,5 – 50,0) mg/100 g P2O5"}],"search_zh":"矿质土壤 有效磷含量 分光光度法 实验室部 范围 PN-R-04023:1996","technique_zh":"分光光度法","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"有效磷含量"},{"_id":"6a83b487af14b9c0e7b20c9a","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość potasu przyswajalnego","parameters":[{"name":"Zakres","range":"(2,0 – 70,0) mg/100 g K2O"}],"technique":"Metoda fotometrii płomieniowej","techniques":["Metoda fotometrii płomieniowej"],"computed":[],"activity":"Zawartość potasu przyswajalnego\nZakres (2,0 – 70,0) mg/100 g K2O\nMetoda fotometrii płomieniowej","reference":"PN-R-04022:1996+Az1:2002","norm_bases":["PN-R-04022:1996+Az1:2002"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość potasu przyswajalnego\nZakres (2,0 – 70,0) mg/100 g K2O\nMetoda fotometrii płomieniowej PN-R-04022:1996+Az1:2002 Gleba mineralna Zawartosc potasu przyswajalnego\nZakres (2,0 – 70,0) mg/100 g K2O\nMetoda fotometrii plomieniowej PN-R-04022:1996+Az1:2002","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available potassium content","parameters_en":[{"name":"Range","range":"(2,0 – 70,0) mg/100 g K2O"}],"search_en":"Mineral soil Available potassium content Flame photometry method Laboratory Department Range PN-R-04022:1996+Az1:2002","technique_en":"Flame photometry method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(2,0 – 70,0) mg/100 g K2O"}],"search_zh":"矿质土壤 速效钾含量 火焰光度法 实验室部 范围 PN-R-04022:1996+Az1:2002","technique_zh":"火焰光度法","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"速效钾含量"},{"_id":"6a83b487af14b9c0e7b20c9b","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość magnezu przyswajalnego","parameters":[{"name":"Zakres","range":"(0,5 – 30,0) mg/100 g"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu przyswajalnego\nZakres (0,5 – 30,0) mg/100 g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04020:1994+Az1:2004","norm_bases":["PN-R-04020:1994+Az1:2004"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość magnezu przyswajalnego\nZakres (0,5 – 30,0) mg/100 g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04020:1994+Az1:2004 Gleba mineralna Zawartosc magnezu przyswajalnego\nZakres (0,5 – 30,0) mg/100 g\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04020:1994+Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available magnesium content","parameters_en":[{"name":"Range","range":"(0,5 – 30,0) mg/100 g"}],"search_en":"Mineral soil Available magnesium content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-R-04020:1994+Az1:2004","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(0,5 – 30,0) mg/100 g"}],"search_zh":"矿质土壤 有效镁含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-R-04020:1994+Az1:2004","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"有效镁含量"},{"_id":"6a83b487af14b9c0e7b20c9c","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość węgla organicznego","parameters":[{"name":"Zakres","range":"(0,29 - 5,8) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość węgla organicznego\nZakres (0,29 - 5,8) %\nMetoda miareczkowa","reference":"PB 06 edycja 7 z dn. 07.06.2021 r.","norm_bases":["PB 06 edycja 7 z dn. 07.06.2021 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość węgla organicznego\nZakres (0,29 - 5,8) %\nMetoda miareczkowa PB 06 edycja 7 z dn. 07.06.2021 r. Gleba mineralna Zawartosc wegla organicznego\nZakres (0,29 - 5,8) %\nMetoda miareczkowa PB 06 edycja 7 z dn. 07.06.2021 r.","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Organic carbon content","parameters_en":[{"name":"Range","range":"(0,29 - 5,8) %"}],"search_en":"Mineral soil Organic carbon content Titrimetric method Laboratory Department Range PB 06 edycja 7 z dn. 07.06.2021 r.","technique_en":"Titrimetric method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(0,29 - 5,8) %"}],"search_zh":"矿质土壤 有机碳含量 滴定法 实验室部 范围 PB 06 edycja 7 z dn. 07.06.2021 r.","technique_zh":"滴定法","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"有机碳含量"},{"_id":"6a83b487af14b9c0e7b20c9d","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość substancji organicznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość substancji organicznej (z obliczeń)","reference":"PB 06 edycja 7 z dn. 07.06.2021 r.","norm_bases":["PB 06 edycja 7 z dn. 07.06.2021 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość substancji organicznej (z obliczeń) PB 06 edycja 7 z dn. 07.06.2021 r. Gleba mineralna Zawartosc substancji organicznej (z obliczen) PB 06 edycja 7 z dn. 07.06.2021 r.","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Organic matter content (calculated)","search_en":"Mineral soil Organic matter content (calculated) Laboratory Department PB 06 edycja 7 z dn. 07.06.2021 r.","test_object_en":"Mineral soil","search_zh":"矿质土壤 有机物质含量（由计算得出） 实验室部 PB 06 edycja 7 z dn. 07.06.2021 r.","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"有机物质含量（由计算得出）"},{"_id":"6a83b487af14b9c0e7b20c9e","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(1,30 - 300) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (1,30 - 300) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB 11 edycja 8 z dn. 30.03.2021 r.","norm_bases":["PB 11 edycja 8 z dn. 30.03.2021 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość azotu amonowego\nZakres (1,30 - 300) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB 11 edycja 8 z dn. 30.03.2021 r. Gleba mineralna Zawartosc azotu amonowego\nZakres (1,30 - 300) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB 11 edycja 8 z dn. 30.03.2021 r.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(1,30 - 300) mg/kg"}],"search_en":"Mineral soil Ammonium nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Laboratory Department Range PB 11 edycja 8 z dn. 30.03.2021 r.","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,30 - 300) mg/kg"}],"search_zh":"矿质土壤 氨氮含量 连续流动分析（CFA）分光光度检测法 实验室部 范围 PB 11 edycja 8 z dn. 30.03.2021 r.","technique_zh":"连续流动分析（CFA）分光光度检测法","methodology_zh":"氨氮含量","test_object_zh":"矿质土壤","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20c9f","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość azotu azotanowego","parameters":[{"name":"Zakres","range":"(1,30 - 300) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Zawartość azotu azotanowego\nZakres (1,30 - 300) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PB 12 edycja 8 z dn. 30.03.2021 r.","norm_bases":["PB 12 edycja 8 z dn. 30.03.2021 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość azotu azotanowego\nZakres (1,30 - 300) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PB 12 edycja 8 z dn. 30.03.2021 r. Gleba mineralna Zawartosc azotu azotanowego\nZakres (1,30 - 300) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PB 12 edycja 8 z dn. 30.03.2021 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Nitrate nitrogen content","parameters_en":[{"name":"Range","range":"(1,30 - 300) mg/kg"}],"search_en":"Mineral soil Nitrate nitrogen content Continuous flow analysis (CFA) with spectrophotometric detection Laboratory Department Range PB 12 edycja 8 z dn. 30.03.2021 r.","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(1,30 - 300) mg/kg"}],"search_zh":"矿质土壤 硝酸盐氮含量 连续流动分析（CFA）分光光度检测法 实验室部 范围 PB 12 edycja 8 z dn. 30.03.2021 r.","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"硝酸盐氮含量"},{"_id":"6a83b487af14b9c0e7b20ca0","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość żelaza przyswajalnego","parameters":[{"name":"Zakres","range":"(20,0 - 5000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość żelaza przyswajalnego\nZakres (20,0 - 5000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04021:1994","norm_bases":["PN-R-04021:1994"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość żelaza przyswajalnego\nZakres (20,0 - 5000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04021:1994 Gleba mineralna Zawartosc zelaza przyswajalnego\nZakres (20,0 - 5000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04021:1994","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available iron content","parameters_en":[{"name":"Range","range":"(20,0 - 5000) mg/kg"}],"search_en":"Mineral soil Available iron content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-R-04021:1994","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(20,0 - 5000) mg/kg"}],"search_zh":"矿质土壤 速效铁含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-R-04021:1994","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"速效铁含量"},{"_id":"6a83b487af14b9c0e7b20ca1","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość manganu przyswajalnego","parameters":[{"name":"Zakres","range":"(5,0 - 1000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość manganu przyswajalnego\nZakres (5,0 - 1000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04019:1993","norm_bases":["PN-R-04019:1993"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość manganu przyswajalnego\nZakres (5,0 - 1000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04019:1993 Gleba mineralna Zawartosc manganu przyswajalnego\nZakres (5,0 - 1000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04019:1993","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available manganese content","parameters_en":[{"name":"Range","range":"(5,0 - 1000) mg/kg"}],"search_en":"Mineral soil Available manganese content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-R-04019:1993","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(5,0 - 1000) mg/kg"}],"search_zh":"矿质土壤 速效锰含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-R-04019:1993","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"速效锰含量"},{"_id":"6a83b487af14b9c0e7b20ca2","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość boru przyswajalnego","parameters":[{"name":"Zakres","range":"(0,50 - 10,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość boru przyswajalnego\nZakres (0,50 - 10,0) mg/kg\nMetoda spektrofotometryczna","reference":"PN-R-04018:1993","norm_bases":["PN-R-04018:1993"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość boru przyswajalnego\nZakres (0,50 - 10,0) mg/kg\nMetoda spektrofotometryczna PN-R-04018:1993 Gleba mineralna Zawartosc boru przyswajalnego\nZakres (0,50 - 10,0) mg/kg\nMetoda spektrofotometryczna PN-R-04018:1993","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available boron content","parameters_en":[{"name":"Range","range":"(0,50 - 10,0) mg/kg"}],"search_en":"Mineral soil Available boron content Spectrophotometric method Laboratory Department Range PN-R-04018:1993","technique_en":"Spectrophotometric method","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(0,50 - 10,0) mg/kg"}],"search_zh":"矿质土壤 分光光度法 实验室部 范围 PN-R-04018:1993","technique_zh":"分光光度法","test_object_zh":"矿质土壤","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20ca3","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość miedzi przyswajalnej","parameters":[{"name":"Zakres","range":"(0,90 – 80,0) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość miedzi przyswajalnej\nZakres (0,90 – 80,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04017:1992","norm_bases":["PN-R-04017:1992"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość miedzi przyswajalnej\nZakres (0,90 – 80,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04017:1992 Gleba mineralna Zawartosc miedzi przyswajalnej\nZakres (0,90 – 80,0) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04017:1992","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available copper content","parameters_en":[{"name":"Range","range":"(0,90 – 80,0) mg/kg"}],"search_en":"Mineral soil Available copper content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-R-04017:1992","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(0,90 – 80,0) mg/kg"}],"search_zh":"矿质土壤 速效铜含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-R-04017:1992","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"速效铜含量"},{"_id":"6a83b487af14b9c0e7b20ca4","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna","methodology":"Zawartość cynku przyswajalnego","parameters":[{"name":"Zakres","range":"(0,80 – 70,0) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość cynku przyswajalnego\nZakres (0,80 – 70,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04016:1992","norm_bases":["PN-R-04016:1992"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna Zawartość cynku przyswajalnego\nZakres (0,80 – 70,0) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04016:1992 Gleba mineralna Zawartosc cynku przyswajalnego\nZakres (0,80 – 70,0) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04016:1992","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available zinc content","parameters_en":[{"name":"Range","range":"(0,80 – 70,0) mg/kg"}],"search_en":"Mineral soil Available zinc content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-R-04016:1992","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral soil","parameters_zh":[{"name":"范围","range":"(0,80 – 70,0) mg/kg"}],"search_zh":"矿质土壤 速效锌含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-R-04016:1992","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿质土壤","lab_section_zh":"实验室部","methodology_zh":"速效锌含量"},{"_id":"6a83b487af14b9c0e7b20ca5","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna, Gleba organiczna","methodology":"pH – w KCl i w H2O","parameters":[{"name":"Zakres","range":"2,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w KCl i w H2O\nZakres 2,0 – 9,0\nMetoda potencjometryczna","reference":"PN-ISO 10390:1997","norm_bases":["PN-ISO 10390:1997"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, Gleba organiczna pH – w KCl i w H2O\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-ISO 10390:1997 Gleba mineralna, Gleba organiczna pH – w KCl i w H2O\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-ISO 10390:1997","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"pH – in KCl and in H2O","parameters_en":[{"name":"Range","range":"2,0 – 9,0"}],"search_en":"pH – in KCl and in H2O Potentiometric method Laboratory Department Range PN-ISO 10390:1997","technique_en":"Potentiometric method","parameters_zh":[{"name":"范围","range":"2,0 – 9,0"}],"search_zh":"电位法 实验室部 范围 PN-ISO 10390:1997","technique_zh":"电位法","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20ca6","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna, Gleba organiczna","methodology":"Azot ogólny Kjeldahla","parameters":[{"name":"Zakres","range":"(0,06 – 4,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Azot ogólny Kjeldahla\nZakres (0,06 – 4,0) %\nMetoda miareczkowa","reference":"PB 13 edycja 7 z dn. 13.05.2019 r.","norm_bases":["PB 13 edycja 7 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, Gleba organiczna Azot ogólny Kjeldahla\nZakres (0,06 – 4,0) %\nMetoda miareczkowa PB 13 edycja 7 z dn. 13.05.2019 r. Gleba mineralna, Gleba organiczna Azot ogolny Kjeldahla\nZakres (0,06 – 4,0) %\nMetoda miareczkowa PB 13 edycja 7 z dn. 13.05.2019 r.","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Total Kjeldahl nitrogen","parameters_en":[{"name":"Range","range":"(0,06 – 4,0) %"}],"search_en":"Total Kjeldahl nitrogen Titrimetric method Laboratory Department Range PB 13 edycja 7 z dn. 13.05.2019 r.","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,06 – 4,0) %"}],"search_zh":"滴定法 实验室部 范围 PB 13 edycja 7 z dn. 13.05.2019 r.","technique_zh":"滴定法","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20ca7","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna, Gleba organiczna","methodology":"Zawartość substancji organicznej","parameters":[{"name":"Zakres","range":"(1,00 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość substancji organicznej\nZakres (1,00 – 95,0) %\nMetoda wagowa","reference":"PB 25 edycja 7 z dn. 13.05.2019 r.","norm_bases":["PB 25 edycja 7 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, Gleba organiczna Zawartość substancji organicznej\nZakres (1,00 – 95,0) %\nMetoda wagowa PB 25 edycja 7 z dn. 13.05.2019 r. Gleba mineralna, Gleba organiczna Zawartosc substancji organicznej\nZakres (1,00 – 95,0) %\nMetoda wagowa PB 25 edycja 7 z dn. 13.05.2019 r.","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Organic matter content","parameters_en":[{"name":"Range","range":"(1,00 – 95,0) %"}],"search_en":"Organic matter content Gravimetric method Laboratory Department Range PB 25 edycja 7 z dn. 13.05.2019 r.","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,00 – 95,0) %"}],"search_zh":"有机物质含量 重量法 实验室部 范围 PB 25 edycja 7 z dn. 13.05.2019 r.","technique_zh":"重量法","lab_section_zh":"实验室部","methodology_zh":"有机物质含量"},{"_id":"6a83b487af14b9c0e7b20ca8","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna, Gleba organiczna","methodology":"Sucha masa/ Zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa/ Zawartość wody\nZakres (0,10 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, Gleba organiczna Sucha masa/ Zawartość wody\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999 Gleba mineralna, Gleba organiczna Sucha masa/ Zawartosc wody\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","parameters_en":[{"name":"Range","range":"(0,10 – 99,9) %"}],"search_en":"Gravimetric method Laboratory Department Range PN-ISO 11465:1999","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 99,9) %"}],"search_zh":"重量法 实验室部 范围 PN-ISO 11465:1999","technique_zh":"重量法","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20ca9","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna, Gleba organiczna","methodology":"Zawartość pierwiastków","parameters":[{"name":"Cu","range":"(5,0 – 320) mg/kg"},{"name":"Pb","range":"(15,0 – 640) mg/kg"},{"name":"Zn","range":"(5,0 – 2000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCu (5,0 – 320) mg/kg\nPb (15,0 – 640) mg/kg\nZn (5,0 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 11466:2002 | PN-ISO 11047:2001","norm_bases":["PN-ISO 11466:2002","PN-ISO 11047:2001"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, Gleba organiczna Zawartość pierwiastków\nZakres:\nCu (5,0 – 320) mg/kg\nPb (15,0 – 640) mg/kg\nZn (5,0 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11466:2002 | PN-ISO 11047:2001 Gleba mineralna, Gleba organiczna Zawartosc pierwiastkow\nZakres:\nCu (5,0 – 320) mg/kg\nPb (15,0 – 640) mg/kg\nZn (5,0 – 2000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11466:2002 | PN-ISO 11047:2001","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Element content","parameters_en":[{"name":"Cu","range":"(5,0 – 320) mg/kg"},{"name":"Pb","range":"(15,0 – 640) mg/kg"},{"name":"Zn","range":"(5,0 – 2000) mg/kg"}],"search_en":"Element content Flame atomic absorption spectrometry (FAAS) Laboratory Department Cu Pb Zn PN-ISO 11466:2002 | PN-ISO 11047:2001","technique_en":"Flame atomic absorption spectrometry (FAAS)","methodology_zh":"元素含量","parameters_zh":[{"name":"Cu","range":"(5,0 – 320) mg/kg"},{"name":"Pb","range":"(15,0 – 640) mg/kg"},{"name":"Zn","range":"(5,0 – 2000) mg/kg"}],"search_zh":"元素含量 火焰原子吸收光谱法（FAAS） 实验室部 Cu Pb Zn PN-ISO 11466:2002 | PN-ISO 11047:2001","technique_zh":"火焰原子吸收光谱法（FAAS）","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20caa","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna, Gleba organiczna","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,002 – 5,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,002 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB 61 edycja 4 z dn.13.05.2019 r.","norm_bases":["PB 61 edycja 4 z dn.13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, Gleba organiczna Zawartość rtęci\nZakres (0,002 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB 61 edycja 4 z dn.13.05.2019 r. Gleba mineralna, Gleba organiczna Zawartosc rteci\nZakres (0,002 – 5,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB 61 edycja 4 z dn.13.05.2019 r.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,002 – 5,00) mg/kg"}],"search_en":"Mercury content Atomic absorption spectrometry with amalgamation technique Laboratory Department Range PB 61 edycja 4 z dn.13.05.2019 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,002 – 5,00) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 实验室部 范围 PB 61 edycja 4 z dn.13.05.2019 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cab","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość fosforu przyswajalnego","parameters":[{"name":"Zakres","range":"(10 – 1250) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (10 – 1250) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość fosforu przyswajalnego\nZakres (10 – 1250) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997 Gleba organiczna Zawartosc fosforu przyswajalnego\nZakres (10 – 1250) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04024:1997","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available phosphorus content","parameters_en":[{"name":"Range","range":"(10 – 1250) mg/100g P2O5"}],"search_en":"Organic soil Available phosphorus content Spectrophotometric method Laboratory Department Range PN-R-04024:1997","technique_en":"Spectrophotometric method","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(10 – 1250) mg/100g P2O5"}],"search_zh":"有机土壤 有效磷含量 分光光度法 实验室部 范围 PN-R-04024:1997","technique_zh":"分光光度法","lab_section_zh":"实验室部","test_object_zh":"有机土壤","methodology_zh":"有效磷含量"},{"_id":"6a83b487af14b9c0e7b20cac","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość potasu przyswajalnego","parameters":[{"name":"Zakres","range":"(5,00 – 200) mg/100g K2O"}],"technique":"Metoda fotometrii płomieniowej","techniques":["Metoda fotometrii płomieniowej"],"computed":[],"activity":"Zawartość potasu przyswajalnego\nZakres (5,00 – 200) mg/100g K2O\nMetoda fotometrii płomieniowej","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość potasu przyswajalnego\nZakres (5,00 – 200) mg/100g K2O\nMetoda fotometrii płomieniowej PN-R-04024:1997 Gleba organiczna Zawartosc potasu przyswajalnego\nZakres (5,00 – 200) mg/100g K2O\nMetoda fotometrii plomieniowej PN-R-04024:1997","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available potassium content","parameters_en":[{"name":"Range","range":"(5,00 – 200) mg/100g K2O"}],"search_en":"Organic soil Available potassium content Flame photometry method Laboratory Department Range PN-R-04024:1997","technique_en":"Flame photometry method","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(5,00 – 200) mg/100g K2O"}],"search_zh":"有机土壤 速效钾含量 火焰光度法 实验室部 范围 PN-R-04024:1997","technique_zh":"火焰光度法","lab_section_zh":"实验室部","test_object_zh":"有机土壤","methodology_zh":"速效钾含量"},{"_id":"6a83b487af14b9c0e7b20cad","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba organiczna","methodology":"Zawartość magnezu przyswajalnego","parameters":[{"name":"Zakres","range":"(10,0 – 400) mg/100g"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu przyswajalnego\nZakres (10,0 – 400) mg/100g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-R-04024:1997","norm_bases":["PN-R-04024:1997"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba organiczna Zawartość magnezu przyswajalnego\nZakres (10,0 – 400) mg/100g\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04024:1997 Gleba organiczna Zawartosc magnezu przyswajalnego\nZakres (10,0 – 400) mg/100g\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-R-04024:1997","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Available magnesium content","parameters_en":[{"name":"Range","range":"(10,0 – 400) mg/100g"}],"search_en":"Organic soil Available magnesium content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-R-04024:1997","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Organic soil","parameters_zh":[{"name":"范围","range":"(10,0 – 400) mg/100g"}],"search_zh":"有机土壤 有效镁含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-R-04024:1997","technique_zh":"火焰原子吸收光谱法（FAAS）","lab_section_zh":"实验室部","test_object_zh":"有机土壤","methodology_zh":"有效镁含量"},{"_id":"6a83b487af14b9c0e7b20cae","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 2,0 – 9,0\nMetoda potencjometryczna","reference":"PB 19 edycja 4 z dn. 13.05.2019 r.","norm_bases":["PB 19 edycja 4 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze pH – w H2O\nZakres 2,0 – 9,0\nMetoda potencjometryczna PB 19 edycja 4 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze pH – w H2O\nZakres 2,0 – 9,0\nMetoda potencjometryczna PB 19 edycja 4 z dn. 13.05.2019 r.","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 – 9,0"}],"search_en":"Soil and horticultural growing media pH – in H2O Potentiometric method Laboratory Department Range PB 19 edycja 4 z dn. 13.05.2019 r.","technique_en":"Potentiometric method","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"2,0 – 9,0"}],"search_zh":"土壤与园艺栽培基质 pH — 于 H2O 中 电位法 实验室部 范围 PB 19 edycja 4 z dn. 13.05.2019 r.","technique_zh":"电位法","lab_section_zh":"实验室部","test_object_zh":"土壤与园艺栽培基质","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a83b487af14b9c0e7b20caf","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zasolenie (NaCl)","parameters":[{"name":"Zakres","range":"(0,02 – 9,0) g/dm3"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Zasolenie (NaCl)\nZakres (0,02 – 9,0) g/dm3\nMetoda konduktometryczna","reference":"PB 20 edycja 4 z dn. 13.05.2019 r.","norm_bases":["PB 20 edycja 4 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zasolenie (NaCl)\nZakres (0,02 – 9,0) g/dm3\nMetoda konduktometryczna PB 20 edycja 4 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze Zasolenie (NaCl)\nZakres (0,02 – 9,0) g/dm3\nMetoda konduktometryczna PB 20 edycja 4 z dn. 13.05.2019 r.","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Salinity (NaCl)","parameters_en":[{"name":"Range","range":"(0,02 – 9,0) g/dm3"}],"search_en":"Soil and horticultural growing media Salinity (NaCl) Conductometric method Laboratory Department Range PB 20 edycja 4 z dn. 13.05.2019 r.","technique_en":"Conductometric method","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(0,02 – 9,0) g/dm3"}],"search_zh":"土壤与园艺栽培基质 电导法 实验室部 范围 PB 20 edycja 4 z dn. 13.05.2019 r.","technique_zh":"电导法","lab_section_zh":"实验室部","test_object_zh":"土壤与园艺栽培基质"},{"_id":"6a83b487af14b9c0e7b20cb0","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(14,0 – 1000) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu\nZakres (14,0 – 1000) mg/dm3\nMetoda spektrofotometryczna","reference":"PB 21 edycja 4 z dn. 13.05.2019 r.","norm_bases":["PB 21 edycja 4 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zawartość fosforu\nZakres (14,0 – 1000) mg/dm3\nMetoda spektrofotometryczna PB 21 edycja 4 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze Zawartosc fosforu\nZakres (14,0 – 1000) mg/dm3\nMetoda spektrofotometryczna PB 21 edycja 4 z dn. 13.05.2019 r.","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Phosphorus content","parameters_en":[{"name":"Range","range":"(14,0 – 1000) mg/dm3"}],"search_en":"Soil and horticultural growing media Phosphorus content Spectrophotometric method Laboratory Department Range PB 21 edycja 4 z dn. 13.05.2019 r.","technique_en":"Spectrophotometric method","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(14,0 – 1000) mg/dm3"}],"search_zh":"土壤与园艺栽培基质 磷含量 分光光度法 实验室部 范围 PB 21 edycja 4 z dn. 13.05.2019 r.","technique_zh":"分光光度法","methodology_zh":"磷含量","lab_section_zh":"实验室部","test_object_zh":"土壤与园艺栽培基质"},{"_id":"6a83b487af14b9c0e7b20cb1","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zawartość potasu","parameters":[{"name":"Zakres","range":"(10,0 – 6000) mg/dm3"}],"technique":"Metoda fotometrii płomieniowej","techniques":["Metoda fotometrii płomieniowej"],"computed":[],"activity":"Zawartość potasu\nZakres (10,0 – 6000) mg/dm3\nMetoda fotometrii płomieniowej","reference":"PB 22 edycja 5 z dn. 13.05.2019 r.","norm_bases":["PB 22 edycja 5 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zawartość potasu\nZakres (10,0 – 6000) mg/dm3\nMetoda fotometrii płomieniowej PB 22 edycja 5 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze Zawartosc potasu\nZakres (10,0 – 6000) mg/dm3\nMetoda fotometrii plomieniowej PB 22 edycja 5 z dn. 13.05.2019 r.","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Potassium content","parameters_en":[{"name":"Range","range":"(10,0 – 6000) mg/dm3"}],"search_en":"Soil and horticultural growing media Potassium content Flame photometry method Laboratory Department Range PB 22 edycja 5 z dn. 13.05.2019 r.","technique_en":"Flame photometry method","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(10,0 – 6000) mg/dm3"}],"search_zh":"土壤与园艺栽培基质 钾含量 火焰光度法 实验室部 范围 PB 22 edycja 5 z dn. 13.05.2019 r.","technique_zh":"火焰光度法","lab_section_zh":"实验室部","methodology_zh":"钾含量","test_object_zh":"土壤与园艺栽培基质"},{"_id":"6a83b487af14b9c0e7b20cb2","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zawartość wapnia","parameters":[{"name":"Zakres","range":"(100 – 6000) mg/dm3"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)"],"computed":[],"activity":"Zawartość wapnia\nZakres (100 – 6000) mg/dm3\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","reference":"PB 63 edycja 3 z dn. 13.05.2019 r.","norm_bases":["PB 63 edycja 3 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zawartość wapnia\nZakres (100 – 6000) mg/dm3\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES) PB 63 edycja 3 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze Zawartosc wapnia\nZakres (100 – 6000) mg/dm3\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FAES) PB 63 edycja 3 z dn. 13.05.2019 r.","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Calcium content","parameters_en":[{"name":"Range","range":"(100 – 6000) mg/dm3"}],"search_en":"Soil and horticultural growing media Calcium content Flame atomic emission spectrometry (FAES) Laboratory Department Range PB 63 edycja 3 z dn. 13.05.2019 r.","technique_en":"Flame atomic emission spectrometry (FAES)","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(100 – 6000) mg/dm3"}],"search_zh":"土壤与园艺栽培基质 钙含量 火焰原子发射光谱法（FAES） 实验室部 范围 PB 63 edycja 3 z dn. 13.05.2019 r.","lab_section_zh":"实验室部","methodology_zh":"钙含量","technique_zh":"火焰原子发射光谱法（FAES）","test_object_zh":"土壤与园艺栽培基质"},{"_id":"6a83b487af14b9c0e7b20cb3","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zawartość magnezu","parameters":[{"name":"Zakres","range":"(7,0 – 750) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu\nZakres (7,0 – 750) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB 23 edycja 4 z dn. 13.05.2019 r","norm_bases":["PB 23 edycja 4 z dn. 13.05.2019 r"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zawartość magnezu\nZakres (7,0 – 750) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB 23 edycja 4 z dn. 13.05.2019 r Gleba i podloza ogrodnicze Zawartosc magnezu\nZakres (7,0 – 750) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB 23 edycja 4 z dn. 13.05.2019 r","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Magnesium content","parameters_en":[{"name":"Range","range":"(7,0 – 750) mg/dm3"}],"search_en":"Soil and horticultural growing media Magnesium content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PB 23 edycja 4 z dn. 13.05.2019 r","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(7,0 – 750) mg/dm3"}],"search_zh":"土壤与园艺栽培基质 镁含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PB 23 edycja 4 z dn. 13.05.2019 r","technique_zh":"火焰原子吸收光谱法（FAAS）","lab_section_zh":"实验室部","methodology_zh":"镁含量","test_object_zh":"土壤与园艺栽培基质"},{"_id":"6a83b487af14b9c0e7b20cb4","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zawartość azotu azotanowego","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/dm3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość azotu azotanowego\nZakres (5,0 – 1000) mg/dm3\nMetoda potencjometryczna","reference":"PB 24 edycja 5 z dn. 13.05.2019 r.","norm_bases":["PB 24 edycja 5 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zawartość azotu azotanowego\nZakres (5,0 – 1000) mg/dm3\nMetoda potencjometryczna PB 24 edycja 5 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze Zawartosc azotu azotanowego\nZakres (5,0 – 1000) mg/dm3\nMetoda potencjometryczna PB 24 edycja 5 z dn. 13.05.2019 r.","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Nitrate nitrogen content","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/dm3"}],"search_en":"Soil and horticultural growing media Nitrate nitrogen content Potentiometric method Laboratory Department Range PB 24 edycja 5 z dn. 13.05.2019 r.","technique_en":"Potentiometric method","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/dm3"}],"search_zh":"土壤与园艺栽培基质 硝酸盐氮含量 电位法 实验室部 范围 PB 24 edycja 5 z dn. 13.05.2019 r.","technique_zh":"电位法","lab_section_zh":"实验室部","test_object_zh":"土壤与园艺栽培基质","methodology_zh":"硝酸盐氮含量"},{"_id":"6a83b487af14b9c0e7b20cb5","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zawartość azotanów","parameters":[{"name":"Zakres","range":"(22,0 – 4400) mg/dm3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość azotanów\nZakres (22,0 – 4400) mg/dm3\nMetoda potencjometryczna","reference":"PB 24 edycja 5 z dn. 13.05.2019 r.","norm_bases":["PB 24 edycja 5 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zawartość azotanów\nZakres (22,0 – 4400) mg/dm3\nMetoda potencjometryczna PB 24 edycja 5 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze Zawartosc azotanow\nZakres (22,0 – 4400) mg/dm3\nMetoda potencjometryczna PB 24 edycja 5 z dn. 13.05.2019 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Nitrate content","parameters_en":[{"name":"Range","range":"(22,0 – 4400) mg/dm3"}],"search_en":"Soil and horticultural growing media Nitrate content Potentiometric method Laboratory Department Range PB 24 edycja 5 z dn. 13.05.2019 r.","technique_en":"Potentiometric method","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(22,0 – 4400) mg/dm3"}],"search_zh":"土壤与园艺栽培基质 硝酸盐含量 电位法 实验室部 范围 PB 24 edycja 5 z dn. 13.05.2019 r.","technique_zh":"电位法","lab_section_zh":"实验室部","methodology_zh":"硝酸盐含量","test_object_zh":"土壤与园艺栽培基质"},{"_id":"6a83b487af14b9c0e7b20cb6","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba i podłoża ogrodnicze","methodology":"Zawartość chlorków","parameters":[{"name":"Zakres","range":"(15,0 – 1000) mg/dm3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość chlorków\nZakres (15,0 – 1000) mg/dm3\nMetoda potencjometryczna","reference":"PB 24 edycja 5 z dn. 13.05.2019 r.","norm_bases":["PB 24 edycja 5 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba i podłoża ogrodnicze Zawartość chlorków\nZakres (15,0 – 1000) mg/dm3\nMetoda potencjometryczna PB 24 edycja 5 z dn. 13.05.2019 r. Gleba i podloza ogrodnicze Zawartosc chlorkow\nZakres (15,0 – 1000) mg/dm3\nMetoda potencjometryczna PB 24 edycja 5 z dn. 13.05.2019 r.","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Chloride content","parameters_en":[{"name":"Range","range":"(15,0 – 1000) mg/dm3"}],"search_en":"Soil and horticultural growing media Chloride content Potentiometric method Laboratory Department Range PB 24 edycja 5 z dn. 13.05.2019 r.","technique_en":"Potentiometric method","test_object_en":"Soil and horticultural growing media","parameters_zh":[{"name":"范围","range":"(15,0 – 1000) mg/dm3"}],"search_zh":"土壤与园艺栽培基质 氯化物含量 电位法 实验室部 范围 PB 24 edycja 5 z dn. 13.05.2019 r.","technique_zh":"电位法","methodology_zh":"氯化物含量","lab_section_zh":"实验室部","test_object_zh":"土壤与园艺栽培基质"},{"_id":"6a83b487af14b9c0e7b20cb7","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Azot ogólny Kjeldahla","parameters":[{"name":"Zakres","range":"(0,40 – 8,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Azot ogólny Kjeldahla\nZakres (0,40 – 8,00) %\nMetoda miareczkowa","reference":"PB 15 edycja 4 z dn. 13.05.2019 r.","norm_bases":["PB 15 edycja 4 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Azot ogólny Kjeldahla\nZakres (0,40 – 8,00) %\nMetoda miareczkowa PB 15 edycja 4 z dn. 13.05.2019 r. Material roslinny Azot ogolny Kjeldahla\nZakres (0,40 – 8,00) %\nMetoda miareczkowa PB 15 edycja 4 z dn. 13.05.2019 r.","categories":["materials"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Total Kjeldahl nitrogen","parameters_en":[{"name":"Range","range":"(0,40 – 8,00) %"}],"search_en":"Plant material Total Kjeldahl nitrogen Titrimetric method Laboratory Department Range PB 15 edycja 4 z dn. 13.05.2019 r.","technique_en":"Titrimetric method","test_object_en":"Plant material","parameters_zh":[{"name":"范围","range":"(0,40 – 8,00) %"}],"search_zh":"植物材料 滴定法 实验室部 范围 PB 15 edycja 4 z dn. 13.05.2019 r.","technique_zh":"滴定法","test_object_zh":"植物材料","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cb8","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość potasu","parameters":[{"name":"Zakres","range":"(0,10 – 8,0) %"}],"technique":"Metoda fotometrii płomieniowej","techniques":["Metoda fotometrii płomieniowej"],"computed":[],"activity":"Zawartość potasu\nZakres (0,10 – 8,0) %\nMetoda fotometrii płomieniowej","reference":"PB 27 edycja 6 z dn. 13.05.2019 r.","norm_bases":["PB 27 edycja 6 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość potasu\nZakres (0,10 – 8,0) %\nMetoda fotometrii płomieniowej PB 27 edycja 6 z dn. 13.05.2019 r. Material roslinny Zawartosc potasu\nZakres (0,10 – 8,0) %\nMetoda fotometrii plomieniowej PB 27 edycja 6 z dn. 13.05.2019 r.","categories":["materials"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Potassium content","parameters_en":[{"name":"Range","range":"(0,10 – 8,0) %"}],"search_en":"Plant material Potassium content Flame photometry method Laboratory Department Range PB 27 edycja 6 z dn. 13.05.2019 r.","technique_en":"Flame photometry method","test_object_en":"Plant material","parameters_zh":[{"name":"范围","range":"(0,10 – 8,0) %"}],"search_zh":"植物材料 钾含量 火焰光度法 实验室部 范围 PB 27 edycja 6 z dn. 13.05.2019 r.","technique_zh":"火焰光度法","test_object_zh":"植物材料","lab_section_zh":"实验室部","methodology_zh":"钾含量"},{"_id":"6a83b487af14b9c0e7b20cb9","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość fosforu","parameters":[{"name":"Zakres","range":"(0,06 – 2,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu\nZakres (0,06 – 2,0) %\nMetoda spektrofotometryczna","reference":"PB 28 edycja 8 z dn. 13.05.2019 r.","norm_bases":["PB 28 edycja 8 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość fosforu\nZakres (0,06 – 2,0) %\nMetoda spektrofotometryczna PB 28 edycja 8 z dn. 13.05.2019 r. Material roslinny Zawartosc fosforu\nZakres (0,06 – 2,0) %\nMetoda spektrofotometryczna PB 28 edycja 8 z dn. 13.05.2019 r.","categories":["materials"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Phosphorus content","parameters_en":[{"name":"Range","range":"(0,06 – 2,0) %"}],"search_en":"Plant material Phosphorus content Spectrophotometric method Laboratory Department Range PB 28 edycja 8 z dn. 13.05.2019 r.","technique_en":"Spectrophotometric method","test_object_en":"Plant material","parameters_zh":[{"name":"范围","range":"(0,06 – 2,0) %"}],"search_zh":"植物材料 磷含量 分光光度法 实验室部 范围 PB 28 edycja 8 z dn. 13.05.2019 r.","technique_zh":"分光光度法","methodology_zh":"磷含量","test_object_zh":"植物材料","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cba","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość magnezu","parameters":[{"name":"Zakres","range":"(0,01 – 2,5) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu\nZakres (0,01 – 2,5) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB 29 edycja 5 z dn. 13.05.2019 r.","norm_bases":["PB 29 edycja 5 z dn. 13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość magnezu\nZakres (0,01 – 2,5) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB 29 edycja 5 z dn. 13.05.2019 r. Material roslinny Zawartosc magnezu\nZakres (0,01 – 2,5) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB 29 edycja 5 z dn. 13.05.2019 r.","categories":["materials"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Magnesium content","parameters_en":[{"name":"Range","range":"(0,01 – 2,5) %"}],"search_en":"Plant material Magnesium content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PB 29 edycja 5 z dn. 13.05.2019 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Plant material","parameters_zh":[{"name":"范围","range":"(0,01 – 2,5) %"}],"search_zh":"植物材料 镁含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PB 29 edycja 5 z dn. 13.05.2019 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"植物材料","lab_section_zh":"实验室部","methodology_zh":"镁含量"},{"_id":"6a83b487af14b9c0e7b20cbb","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,002 – 2,00) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,002 – 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB 61 edycja 4 z dn.13.05.2019 r.","norm_bases":["PB 61 edycja 4 z dn.13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość rtęci\nZakres (0,002 – 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB 61 edycja 4 z dn.13.05.2019 r. Material roslinny Zawartosc rteci\nZakres (0,002 – 2,00) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB 61 edycja 4 z dn.13.05.2019 r.","categories":["materials"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,002 – 2,00) mg/kg"}],"search_en":"Plant material Mercury content Atomic absorption spectrometry with amalgamation technique Laboratory Department Range PB 61 edycja 4 z dn.13.05.2019 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Plant material","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,002 – 2,00) mg/kg"}],"search_zh":"植物材料 汞含量 原子吸收光谱法（汞齐化技术） 实验室部 范围 PB 61 edycja 4 z dn.13.05.2019 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"植物材料","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cbc","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość wapnia","parameters":[{"name":"Zakres","range":"(0,50 – 60,0) % CaO"}],"technique":"Metoda miareczkowa (manganometryczna)","techniques":["Metoda miareczkowa (manganometryczna)"],"computed":[],"activity":"Zawartość wapnia\nZakres (0,50 – 60,0) % CaO\nMetoda miareczkowa (manganometryczna)","reference":"PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16196:2013","norm_bases":["PN-EN 15960:2011","PN-EN 15961:2017-02","PN-EN 16196:2013"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość wapnia\nZakres (0,50 – 60,0) % CaO\nMetoda miareczkowa (manganometryczna) PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16196:2013 Nawozy mineralne (nieorganiczne) Zawartosc wapnia\nZakres (0,50 – 60,0) % CaO\nMetoda miareczkowa (manganometryczna) PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16196:2013","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Calcium content","parameters_en":[{"name":"Range","range":"(0,50 – 60,0) % CaO"}],"search_en":"Mineral (inorganic) fertilisers Calcium content Titrimetric method (manganometric) Laboratory Department Range PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16196:2013","technique_en":"Titrimetric method (manganometric)","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,50 – 60,0) % CaO"}],"search_zh":"矿物（无机）肥料 钙含量 实验室部 范围 PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16196:2013","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"钙含量"},{"_id":"6a83b487af14b9c0e7b20cbd","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość fosforu rozpuszczalnego w wodzie","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) % P2O5"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość fosforu rozpuszczalnego w wodzie\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa","reference":"PN-EN 15958:2011 | PN-EN 15959:2024-05","norm_bases":["PN-EN 15958:2011","PN-EN 15959:2024-05"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość fosforu rozpuszczalnego w wodzie\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa PN-EN 15958:2011 | PN-EN 15959:2024-05 Nawozy mineralne (nieorganiczne) Zawartosc fosforu rozpuszczalnego w wodzie\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa PN-EN 15958:2011 | PN-EN 15959:2024-05","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Water-soluble phosphorus content","parameters_en":[{"name":"Range","range":"(0,5 – 50,0) % P2O5"}],"search_en":"Mineral (inorganic) fertilisers Water-soluble phosphorus content Gravimetric method Laboratory Department Range PN-EN 15958:2011 | PN-EN 15959:2024-05","technique_en":"Gravimetric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) % P2O5"}],"search_zh":"矿物（无机）肥料 水溶性磷含量 重量法 实验室部 范围 PN-EN 15958:2011 | PN-EN 15959:2024-05","technique_zh":"重量法","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"水溶性磷含量"},{"_id":"6a83b487af14b9c0e7b20cbe","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość fosforu rozpuszczalnego w kwasach","parameters":[{"name":"Zakres","range":"(1,0 - 50,0) % P2O5"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość fosforu rozpuszczalnego w kwasach\nZakres (1,0 - 50,0) % P2O5\nMetoda wagowa","reference":"PN-EN 15956:2011 | PN-EN 15959:2024-05","norm_bases":["PN-EN 15956:2011","PN-EN 15959:2024-05"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość fosforu rozpuszczalnego w kwasach\nZakres (1,0 - 50,0) % P2O5\nMetoda wagowa PN-EN 15956:2011 | PN-EN 15959:2024-05 Nawozy mineralne (nieorganiczne) Zawartosc fosforu rozpuszczalnego w kwasach\nZakres (1,0 - 50,0) % P2O5\nMetoda wagowa PN-EN 15956:2011 | PN-EN 15959:2024-05","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Content of phosphorus soluble in acids","parameters_en":[{"name":"Range","range":"(1,0 - 50,0) % P2O5"}],"search_en":"Mineral (inorganic) fertilisers Content of phosphorus soluble in acids Gravimetric method Laboratory Department Range PN-EN 15956:2011 | PN-EN 15959:2024-05","technique_en":"Gravimetric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(1,0 - 50,0) % P2O5"}],"search_zh":"矿物（无机）肥料 重量法 实验室部 范围 PN-EN 15956:2011 | PN-EN 15959:2024-05","technique_zh":"重量法","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cbf","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość fosforu rozpuszczalnego w obojętnym cytrynianie amonu i wodzie","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) % P2O5"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość fosforu rozpuszczalnego w obojętnym cytrynianie amonu i wodzie\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa","reference":"PN-C-87015:1988 rozd.6 | PN-EN 15959:2024-05","norm_bases":["PN-C-87015:1988 rozd.6","PN-EN 15959:2024-05"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość fosforu rozpuszczalnego w obojętnym cytrynianie amonu i wodzie\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa PN-C-87015:1988 rozd.6 | PN-EN 15959:2024-05 Nawozy mineralne (nieorganiczne) Zawartosc fosforu rozpuszczalnego w obojetnym cytrynianie amonu i wodzie\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa PN-C-87015:1988 rozd.6 | PN-EN 15959:2024-05","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Content of phosphorus soluble in neutral ammonium citrate and water","parameters_en":[{"name":"Range","range":"(0,5 – 50,0) % P2O5"}],"search_en":"Mineral (inorganic) fertilisers Content of phosphorus soluble in neutral ammonium citrate and water Gravimetric method Laboratory Department Range PN-C-87015:1988 rozd.6 | PN-EN 15959:2024-05","technique_en":"Gravimetric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) % P2O5"}],"search_zh":"矿物（无机）肥料 重量法 实验室部 范围 PN-C-87015:1988 rozd.6 | PN-EN 15959:2024-05","technique_zh":"重量法","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cc0","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość fosforu rozpuszczalnego w obojętnym cytrynianie amonu","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) % P2O5"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość fosforu rozpuszczalnego w obojętnym cytrynianie amonu\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa","reference":"PN-EN 15957:2011 | PN-EN 15959:2024-05","norm_bases":["PN-EN 15957:2011","PN-EN 15959:2024-05"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość fosforu rozpuszczalnego w obojętnym cytrynianie amonu\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa PN-EN 15957:2011 | PN-EN 15959:2024-05 Nawozy mineralne (nieorganiczne) Zawartosc fosforu rozpuszczalnego w obojetnym cytrynianie amonu\nZakres (0,5 – 50,0) % P2O5\nMetoda wagowa PN-EN 15957:2011 | PN-EN 15959:2024-05","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Content of phosphorus soluble in neutral ammonium citrate","parameters_en":[{"name":"Range","range":"(0,5 – 50,0) % P2O5"}],"search_en":"Mineral (inorganic) fertilisers Content of phosphorus soluble in neutral ammonium citrate Gravimetric method Laboratory Department Range PN-EN 15957:2011 | PN-EN 15959:2024-05","technique_en":"Gravimetric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) % P2O5"}],"search_zh":"矿物（无机）肥料 中性柠檬酸铵可溶磷含量 重量法 实验室部 范围 PN-EN 15957:2011 | PN-EN 15959:2024-05","technique_zh":"重量法","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"中性柠檬酸铵可溶磷含量"},{"_id":"6a83b487af14b9c0e7b20cc1","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość potasu","parameters":[{"name":"Zakres","range":"(0,5 - 65,0) % K2O"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość potasu\nZakres (0,5 - 65,0) % K2O\nMetoda wagowa","reference":"PN-EN 15477:2009","norm_bases":["PN-EN 15477:2009"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość potasu\nZakres (0,5 - 65,0) % K2O\nMetoda wagowa PN-EN 15477:2009 Nawozy mineralne (nieorganiczne) Zawartosc potasu\nZakres (0,5 - 65,0) % K2O\nMetoda wagowa PN-EN 15477:2009","categories":["other"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Potassium content","parameters_en":[{"name":"Range","range":"(0,5 - 65,0) % K2O"}],"search_en":"Mineral (inorganic) fertilisers Potassium content Gravimetric method Laboratory Department Range PN-EN 15477:2009","technique_en":"Gravimetric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,5 - 65,0) % K2O"}],"search_zh":"矿物（无机）肥料 钾含量 重量法 实验室部 范围 PN-EN 15477:2009","technique_zh":"重量法","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"钾含量"},{"_id":"6a83b487af14b9c0e7b20cc2","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość magnezu","parameters":[{"name":"Zakres","range":"(0,50 – 22,0) % MgO"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu\nZakres (0,50 – 22,0) % MgO\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16197:2013-05","norm_bases":["PN-EN 15960:2011","PN-EN 15961:2017-02","PN-EN 16197:2013-05"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość magnezu\nZakres (0,50 – 22,0) % MgO\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16197:2013-05 Nawozy mineralne (nieorganiczne) Zawartosc magnezu\nZakres (0,50 – 22,0) % MgO\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16197:2013-05","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Magnesium content","parameters_en":[{"name":"Range","range":"(0,50 – 22,0) % MgO"}],"search_en":"Mineral (inorganic) fertilisers Magnesium content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16197:2013-05","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,50 – 22,0) % MgO"}],"search_zh":"矿物（无机）肥料 镁含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-EN 15960:2011 | PN-EN 15961:2017-02 | PN-EN 16197:2013-05","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"镁含量"},{"_id":"6a83b487af14b9c0e7b20cc3","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość azotu azotanowego i amonowego wg Devarda","parameters":[{"name":"Zakres","range":"(1,75 - 36,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu azotanowego i amonowego wg Devarda\nZakres (1,75 - 36,0) %\nMetoda miareczkowa","reference":"PN-EN 15476:2009","norm_bases":["PN-EN 15476:2009"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość azotu azotanowego i amonowego wg Devarda\nZakres (1,75 - 36,0) %\nMetoda miareczkowa PN-EN 15476:2009 Nawozy mineralne (nieorganiczne) Zawartosc azotu azotanowego i amonowego wg Devarda\nZakres (1,75 - 36,0) %\nMetoda miareczkowa PN-EN 15476:2009","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Nitrate and ammonium nitrogen content according to Devarda","parameters_en":[{"name":"Range","range":"(1,75 - 36,0) %"}],"search_en":"Mineral (inorganic) fertilisers Nitrate and ammonium nitrogen content according to Devarda Titrimetric method Laboratory Department Range PN-EN 15476:2009","technique_en":"Titrimetric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(1,75 - 36,0) %"}],"search_zh":"矿物（无机）肥料 按德瓦达法测定的硝酸盐氮与铵态氮含量 滴定法 实验室部 范围 PN-EN 15476:2009","technique_zh":"滴定法","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"按德瓦达法测定的硝酸盐氮与铵态氮含量"},{"_id":"6a83b487af14b9c0e7b20cc4","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 - 36,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (1,0 - 36,0) %\nMetoda miareczkowa","reference":"PN-EN 15475:2009","norm_bases":["PN-EN 15475:2009"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość azotu amonowego\nZakres (1,0 - 36,0) %\nMetoda miareczkowa PN-EN 15475:2009 Nawozy mineralne (nieorganiczne) Zawartosc azotu amonowego\nZakres (1,0 - 36,0) %\nMetoda miareczkowa PN-EN 15475:2009","categories":["other"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(1,0 - 36,0) %"}],"search_en":"Mineral (inorganic) fertilisers Ammonium nitrogen content Titrimetric method Laboratory Department Range PN-EN 15475:2009","technique_en":"Titrimetric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(1,0 - 36,0) %"}],"search_zh":"矿物（无机）肥料 氨氮含量 滴定法 实验室部 范围 PN-EN 15475:2009","technique_zh":"滴定法","test_object_zh":"矿物（无机）肥料","methodology_zh":"氨氮含量","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cc5","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość boru","parameters":[{"name":"Zakres","range":"(0,01 - 10,0)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość boru\nZakres (0,01 - 10,0)%\nMetoda spektrofotometryczna","reference":"PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 17041:2018-07","norm_bases":["PN-EN 16962:2018-03","PN-EN 16964:2018-03","PN-EN 17041:2018-07"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość boru\nZakres (0,01 - 10,0)%\nMetoda spektrofotometryczna PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 17041:2018-07 Nawozy mineralne (nieorganiczne) Zawartosc boru\nZakres (0,01 - 10,0)%\nMetoda spektrofotometryczna PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 17041:2018-07","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Boron content","parameters_en":[{"name":"Range","range":"(0,01 - 10,0)%"}],"search_en":"Mineral (inorganic) fertilisers Boron content Spectrophotometric method Laboratory Department Range PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 17041:2018-07","technique_en":"Spectrophotometric method","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,01 - 10,0)%"}],"search_zh":"矿物（无机）肥料 硼含量 分光光度法 实验室部 范围 PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 17041:2018-07","technique_zh":"分光光度法","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"硼含量"},{"_id":"6a83b487af14b9c0e7b20cc6","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość cynku, manganu, żelaza","parameters":[{"name":"Zakres","range":"(0,01 - 10,0) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość cynku, manganu, żelaza\nZakres (0,01 - 10,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","norm_bases":["PN-EN 16962:2018-03","PN-EN 16964:2018-03","PN-EN 16965:2018-03"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość cynku, manganu, żelaza\nZakres (0,01 - 10,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03 Nawozy mineralne (nieorganiczne) Zawartosc cynku, manganu, zelaza\nZakres (0,01 - 10,0) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Zinc, manganese, iron content","parameters_en":[{"name":"Range","range":"(0,01 - 10,0) %"}],"search_en":"Mineral (inorganic) fertilisers Zinc, manganese, iron content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,01 - 10,0) %"}],"search_zh":"矿物（无机）肥料 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部"},{"_id":"6a83b487af14b9c0e7b20cc7","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy mineralne (nieorganiczne)","methodology":"Zawartość miedzi","parameters":[{"name":"Zakres","range":"(0,001 - 10,0) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość miedzi\nZakres (0,001 - 10,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","norm_bases":["PN-EN 16962:2018-03","PN-EN 16964:2018-03","PN-EN 16965:2018-03"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy mineralne (nieorganiczne) Zawartość miedzi\nZakres (0,001 - 10,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03 Nawozy mineralne (nieorganiczne) Zawartosc miedzi\nZakres (0,001 - 10,0) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","categories":["other"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Copper content","parameters_en":[{"name":"Range","range":"(0,001 - 10,0) %"}],"search_en":"Mineral (inorganic) fertilisers Copper content Flame atomic absorption spectrometry (FAAS) Laboratory Department Range PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Mineral (inorganic) fertilisers","parameters_zh":[{"name":"范围","range":"(0,001 - 10,0) %"}],"search_zh":"矿物（无机）肥料 铜含量 火焰原子吸收光谱法（FAAS） 实验室部 范围 PN-EN 16962:2018-03 | PN-EN 16964:2018-03 | PN-EN 16965:2018-03","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"矿物（无机）肥料","lab_section_zh":"实验室部","methodology_zh":"铜含量"},{"_id":"6a83b487af14b9c0e7b20cc8","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Mocznik","methodology":"Zawartość azotu całkowitego","parameters":[{"name":"Zakres","range":"(30,0 - 50,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu całkowitego\nZakres (30,0 - 50,0) %\nMetoda miareczkowa","reference":"PN-EN 15478:2009","norm_bases":["PN-EN 15478:2009"],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mocznik Zawartość azotu całkowitego\nZakres (30,0 - 50,0) %\nMetoda miareczkowa PN-EN 15478:2009 Mocznik Zawartosc azotu calkowitego\nZakres (30,0 - 50,0) %\nMetoda miareczkowa PN-EN 15478:2009","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(30,0 - 50,0) %"}],"search_en":"Urea Total nitrogen content Titrimetric method Laboratory Department Range PN-EN 15478:2009","technique_en":"Titrimetric method","test_object_en":"Urea","parameters_zh":[{"name":"范围","range":"(30,0 - 50,0) %"}],"search_zh":"尿素 总氮含量 滴定法 实验室部 范围 PN-EN 15478:2009","technique_zh":"滴定法","lab_section_zh":"实验室部","methodology_zh":"总氮含量","test_object_zh":"尿素"},{"_id":"6a83b487af14b9c0e7b20cc9","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość suchej masy i wody","parameters":[{"name":"Zakres","range":"(0,01 - 99,90) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość suchej masy i wody\nZakres (0,01 - 99,90) %\nMetoda wagowa","reference":"PB 05 edycja 6 z dn.13.05.2019 r.","norm_bases":["PB 05 edycja 6 z dn.13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość suchej masy i wody\nZakres (0,01 - 99,90) %\nMetoda wagowa PB 05 edycja 6 z dn.13.05.2019 r. Nawozy naturalne, organiczne, organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc suchej masy i wody\nZakres (0,01 - 99,90) %\nMetoda wagowa PB 05 edycja 6 z dn.13.05.2019 r.","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Dry matter and water content","parameters_en":[{"name":"Range","range":"(0,01 - 99,90) %"}],"search_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media Dry matter and water content Gravimetric method Laboratory Department Range PB 05 edycja 6 z dn.13.05.2019 r.","technique_en":"Gravimetric method","test_object_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media","parameters_zh":[{"name":"范围","range":"(0,01 - 99,90) %"}],"search_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 干物质与水分含量 重量法 实验室部 范围 PB 05 edycja 6 z dn.13.05.2019 r.","technique_zh":"重量法","lab_section_zh":"实验室部","methodology_zh":"干物质与水分含量","test_object_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a83b487af14b9c0e7b20cca","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość potasu","parameters":[{"name":"próbki stałe","range":"(0,400 – 8,00 ) %"},{"name":"próbki płynne","range":"(0,020 – 0,800) %"}],"technique":"Metoda fotometrii płomieniowej","techniques":["Metoda fotometrii płomieniowej"],"computed":[],"activity":"Zawartość potasu\nZakres:\npróbki stałe (0,400 – 8,00 ) %\npróbki płynne (0,020 – 0,800) %\nMetoda fotometrii płomieniowej","reference":"PB 55 edycja 4 z dn.13.05.2019 r.","norm_bases":["PB 55 edycja 4 z dn.13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość potasu\nZakres:\npróbki stałe (0,400 – 8,00 ) %\npróbki płynne (0,020 – 0,800) %\nMetoda fotometrii płomieniowej PB 55 edycja 4 z dn.13.05.2019 r. Nawozy naturalne, organiczne, organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc potasu\nZakres:\nprobki stale (0,400 – 8,00 ) %\nprobki plynne (0,020 – 0,800) %\nMetoda fotometrii plomieniowej PB 55 edycja 4 z dn.13.05.2019 r.","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Potassium content","parameters_en":[{"name":"solid samples","range":"(0,400 – 8,00 ) %"},{"name":"liquid samples","range":"(0,020 – 0,800) %"}],"search_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media Potassium content Flame photometry method Laboratory Department solid samples liquid samples PB 55 edycja 4 z dn.13.05.2019 r.","technique_en":"Flame photometry method","test_object_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media","search_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 钾含量 火焰光度法 实验室部 PB 55 edycja 4 z dn.13.05.2019 r.","technique_zh":"火焰光度法","lab_section_zh":"实验室部","methodology_zh":"钾含量","test_object_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a83b487af14b9c0e7b20ccb","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"próbki stałe","range":"(0,130 – 10,00) %"},{"name":"próbki płynne","range":"(0,006 – 1,00) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\npróbki stałe (0,130 – 10,00) %\npróbki płynne (0,006 – 1,00) %\nMetoda spektrofotometryczna","reference":"PB 56 edycja 5 z dn.13.05.2019 r.","norm_bases":["PB 56 edycja 5 z dn.13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość fosforu ogólnego\nZakres:\npróbki stałe (0,130 – 10,00) %\npróbki płynne (0,006 – 1,00) %\nMetoda spektrofotometryczna PB 56 edycja 5 z dn.13.05.2019 r. Nawozy naturalne, organiczne, organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc fosforu ogolnego\nZakres:\nprobki stale (0,130 – 10,00) %\nprobki plynne (0,006 – 1,00) %\nMetoda spektrofotometryczna PB 56 edycja 5 z dn.13.05.2019 r.","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Total phosphorus content","parameters_en":[{"name":"solid samples","range":"(0,130 – 10,00) %"},{"name":"liquid samples","range":"(0,006 – 1,00) %"}],"search_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media Total phosphorus content Spectrophotometric method Laboratory Department solid samples liquid samples PB 56 edycja 5 z dn.13.05.2019 r.","technique_en":"Spectrophotometric method","test_object_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media","search_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 总磷含量 分光光度法 实验室部 PB 56 edycja 5 z dn.13.05.2019 r.","technique_zh":"分光光度法","methodology_zh":"总磷含量","lab_section_zh":"实验室部","test_object_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a83b487af14b9c0e7b20ccc","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"próbki stałe","range":"(0,280 – 10,00) %"},{"name":"próbki płynne","range":"(0,014 – 1,000 ) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres:\npróbki stałe (0,280 – 10,00) %\npróbki płynne (0,014 – 1,000 ) %\nMetoda miareczkowa","reference":"PB 58 edycja 4 z dn.13.05.2019 r.","norm_bases":["PB 58 edycja 4 z dn.13.05.2019 r."],"lab_section":"Dział Laboratoryjny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy naturalne, organiczne, organiczno-mineralne, Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby (polepszacze gleby) - podłoża do upraw Zawartość azotu ogólnego\nZakres:\npróbki stałe (0,280 – 10,00) %\npróbki płynne (0,014 – 1,000 ) %\nMetoda miareczkowa PB 58 edycja 4 z dn.13.05.2019 r. Nawozy naturalne, organiczne, organiczno-mineralne, Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby (polepszacze gleby) - podloza do upraw Zawartosc azotu ogolnego\nZakres:\nprobki stale (0,280 – 10,00) %\nprobki plynne (0,014 – 1,000 ) %\nMetoda miareczkowa PB 58 edycja 4 z dn.13.05.2019 r.","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Department","methodology_en":"Total nitrogen content","parameters_en":[{"name":"solid samples","range":"(0,280 – 10,00) %"},{"name":"liquid samples","range":"(0,014 – 1,000 ) %"}],"search_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media Total nitrogen content Titrimetric method Laboratory Department solid samples liquid samples PB 58 edycja 4 z dn.13.05.2019 r.","technique_en":"Titrimetric method","test_object_en":"Natural, organic and organic-mineral fertilisers, Plant cultivation aids: - soil improvers - growing media","search_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质 总氮含量 滴定法 实验室部 PB 58 edycja 4 z dn.13.05.2019 r.","technique_zh":"滴定法","lab_section_zh":"实验室部","methodology_zh":"总氮含量","test_object_zh":"农家肥、有机肥、有机-矿物肥；植物栽培辅助制剂：－ 土壤改良剂 － 栽培基质"},{"_id":"6a83b487af14b9c0e7b20ccd","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba mineralna, Gleba organiczna","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-R-04031:1997","norm_bases":["PN-R-04031:1997"],"lab_section":"Dział Agrochemicznej Obsługi Rolnictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba mineralna, Gleba organiczna Pobieranie próbek do badań fizycznych i chemicznych PN-R-04031:1997 Gleba mineralna, Gleba organiczna Pobieranie probek do badan fizycznych i chemicznych PN-R-04031:1997","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Sampling for physical and chemical testing PN-R-04031:1997","methodology_zh":"物理与化学检测用样品采集","search_zh":"物理与化学检测用样品采集 PN-R-04031:1997"},{"_id":"6a83b487af14b9c0e7b20cce","lab_id":"69ad52a3de79e566650fb42a","country":"PL","accr_number":"AB 827","accr_body":"PCA","test_object":"Gleba ogrodnicza","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"IPP 01/ PN-R-04031:1997 edycja 2 z dn. 31.03.2017","norm_bases":["IPP 01/ PN-R-04031:1997 edycja 2 z dn. 31.03.2017"],"lab_section":"Dział Agrochemicznej Obsługi Rolnictwa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba ogrodnicza Pobieranie próbek do badań fizycznych i chemicznych IPP 01/ PN-R-04031:1997 edycja 2 z dn. 31.03.2017 Gleba ogrodnicza Pobieranie probek do badan fizycznych i chemicznych IPP 01/ PN-R-04031:1997 edycja 2 z dn. 31.03.2017","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Sampling for physical and chemical testing IPP 01/ PN-R-04031:1997 edycja 2 z dn. 31.03.2017","methodology_zh":"物理与化学检测用样品采集","search_zh":"物理与化学检测用样品采集 IPP 01/ PN-R-04031:1997 edycja 2 z dn. 31.03.2017"}],"has_pdf":true}