{"lab":{"_id":"69ad52a3de79e566650fb422","accr_number":"AB 821","country":"PL","accr_body":"PCA","address":"Henryk Gracka, Marek Lepiorz, Krzysztof Bloch, Jakub Łubiński, LABORATORIUM HIGIENY PRACY, ul. Radoszowska 46, 41-707 Ruda Śląska","categories":["environment"],"city":"Ruda Śląska","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"PRZEDSIĘBIORSTWO BADAŃ ŚRODOWISKA „SANUM” S.C.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_821.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo badań środowiska „sanum” s.c. henryk gracka, marek lepiorz, krzysztof bloch, jakub łubiński, laboratorium higieny pracy, ul. radoszowska 46, 41-707 ruda śląska environment metrology other pharma electronics materials automotive construction food","status":"active","updated_at":"2026-03-08T14:51:42.629Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:11:12.695Z","location":{"type":"Point","coordinates":[18.8556,50.2558]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20821,plik.html","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors – noise, lighting, vibration, microclimate)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - noise)"},{"codes":"G/35","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – pomieszczenia (warunki środowiskowe – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - facilities (environmental conditions - noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"24","date":"11.06.2026"},"parse_date":"2026-08-18T01:11:12.695Z","parse_source":"agent-claude-code","map_coord":[50.254958,18.923054],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM HIGIENY PRACY","address":"ul. Radoszowska 46","city":null,"postal":null},{"name":"Pracownia Fizyczna","address":"ul. Radoszowska 46; 41-707 Ruda Śląska","city":"Ruda Śląska","postal":"41-707"},{"name":"Pracownia Chemiczna","address":"ul. Radoszowska 46; 41-707 Ruda Śląska","city":"Ruda Śląska","postal":"41-707"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/a7e16d76090e679f59f5aa7deb0ae23b/AB%20821.pdf","has_en":true,"category_counts":{"environment":43,"construction":2,"petro":1,"materials":1},"category_scores":{"environment":39.34,"construction":0.09,"petro":0.02,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a83b130af14b9c0e7b20783","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 135,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40,0 –136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 – 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (40,0 –136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 – 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (40,0 –136,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25,0 – 135,0) dB\nSzczytowy poziom dzwieku C\nZakres (40,0 –136,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 – punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25,0 – 135,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40,0 –136,0) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25,0 – 135,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40,0 –136,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b130af14b9c0e7b20784","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 – punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b130af14b9c0e7b20785","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24,0 – 115,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (24,0 – 115,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (24,0 – 115,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (24,0 – 115,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(24,0 – 115,0) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(24,0 – 115,0) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83b130af14b9c0e7b20786","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A, Dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A, Dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A, Dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A, Dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level, For the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound level, For the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83b130af14b9c0e7b20787","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(20,0 – 80,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (20,0 – 80,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (20,0 – 80,0) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (20,0 – 80,0) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(20,0 – 80,0) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-87/B-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(20,0 – 80,0) dB"}],"search_zh":"住宅、集体居住与公共建筑内的房间 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 — 噪声"},{"_id":"6a83b130af14b9c0e7b20788","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej - hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej - halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings - noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings - noise","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住与公共建筑内的房间 — 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住与公共建筑内的房间 — 噪声"},{"_id":"6a83b130af14b9c0e7b20789","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 10000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 10000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b130af14b9c0e7b2078a","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b130af14b9c0e7b2078b","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 1500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 1500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Natężenie oświetlenia\nZakres (0,5 – 1500) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne na zewnatrz Natezenie oswietlenia\nZakres (0,5 – 1500) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 1500) lx"}],"search_en":"Workplace environment - outdoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - outdoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 1500) lx"}],"search_zh":"工作场所环境 — 室外电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室外电气照明"},{"_id":"6a83b130af14b9c0e7b2078c","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - outdoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - outdoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室外电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室外电气照明"},{"_id":"6a83b130af14b9c0e7b2078d","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2005 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method Range PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 范围 PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b130af14b9c0e7b2078e","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek maksymalnego do minimalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek maksymalnego do minimalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek maksymalnego do minimalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Stosunek maksymalnego do minimalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2005 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of maximum to minimum illuminance (calculated)","search_en":"Workplace environment - emergency lighting Ratio of maximum to minimum illuminance (calculated) PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_en":"Workplace environment - emergency lighting","search_zh":"工作场所环境 — 应急照明 最大照度与最小照度之比（由计算得出） PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"最大照度与最小照度之比（由计算得出）"},{"_id":"6a83b130af14b9c0e7b2078f","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2005 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment - emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_en":"Workplace environment - emergency lighting","search_zh":"工作场所环境 — 应急照明 高风险区照度均匀度（计算值） PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"高风险区照度均匀度（计算值）"},{"_id":"6a83b130af14b9c0e7b20790","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Czas załączania","parameters":[{"name":"Zakres","range":"(1 – 3600) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Czas załączania\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Czas zalaczania\nZakres (1 – 3600) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2005 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Closing time","parameters_en":[{"name":"Range","range":"(1 – 3600) s"}],"search_en":"Workplace environment - emergency lighting Closing time Direct measurement method Range PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","parameters_zh":[{"name":"范围","range":"(1 – 3600) s"}],"search_zh":"工作场所环境 — 应急照明 接通时间 直接测量法 范围 PN-EN 1838:2005 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"接通时间"},{"_id":"6a83b130af14b9c0e7b20791","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b130af14b9c0e7b20792","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83b130af14b9c0e7b20793","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment - emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_en":"Workplace environment - emergency lighting","search_zh":"工作场所环境 — 应急照明 高风险区照度均匀度（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"高风险区照度均匀度（计算值）"},{"_id":"6a83b130af14b9c0e7b20794","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Czas załączania","parameters":[{"name":"Zakres","range":"(1 – 3600) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Czas załączania\nZakres (1 – 3600) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5 Srodowisko pracy - oswietlenie awaryjne Czas zalaczania\nZakres (1 – 3600) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Closing time","parameters_en":[{"name":"Range","range":"(1 – 3600) s"}],"search_en":"Workplace environment - emergency lighting Closing time Direct measurement method Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","parameters_zh":[{"name":"范围","range":"(1 – 3600) s"}],"search_zh":"工作场所环境 — 应急照明 接通时间 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.3.3, 4.4.3, 5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"接通时间"},{"_id":"6a83b130af14b9c0e7b20795","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10,0 – 30,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10,0 – 35,0) 0C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(16,0 – 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) 0C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) 0C\nWilgotność powietrza\nZakres (16,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2026-03","norm_bases":["PN-EN ISO 7730:2026-03"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) 0C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) 0C\nWilgotność powietrza\nZakres (16,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2026-03 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) 0C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) 0C\nWilgotnosc powietrza\nZakres (16,0 – 90,0) %\nPredkosc powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2026-03","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10,0 – 30,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10,0 – 35,0) 0C"},{"name":"Air humidity"},{"name":"Range","range":"(16,0 – 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1,0) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2026-03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10,0 – 30,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(10,0 – 35,0) 0C"},{"name":"空气湿度"},{"name":"范围","range":"(16,0 – 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2026-03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b130af14b9c0e7b20796","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2026-03","norm_bases":["PN-EN ISO 7730:2026-03"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2026-03 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2026-03","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2026-03","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2026-03","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b130af14b9c0e7b20797","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30,0 –10,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30,0 – 15,0) 0C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(16,0 – 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30,0 –10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (16,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 - 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 –10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotność powietrza\nZakres (16,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 - 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 –10,0) 0C\nTemperatura poczernionej kuli\nZakres (-30,0 – 15,0) 0C\nWilgotnosc powietrza\nZakres (16,0 – 90,0) %\nPredkosc powietrza\nZakres (0,15 - 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30,0 –10,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30,0 – 15,0) 0C"},{"name":"Air humidity"},{"name":"Range","range":"(16,0 – 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 5,0) m/s"}],"search_en":"Workplace environment − cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30,0 –10,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(-30,0 – 15,0) 0C"},{"name":"空气湿度"},{"name":"范围","range":"(16,0 – 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 5,0) m/s"}],"search_zh":"工作场所环境 − 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a83b130af14b9c0e7b20798","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy − mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment − cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment − cold microclimate","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）","search_zh":"工作场所环境 − 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 − 低温微气候"},{"_id":"6a83b130af14b9c0e7b20799","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(20,0 – 60,0) 0C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15,0 – 50,0) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(20,0 – 70,0) 0C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (20,0 – 60,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (20,0 – 70,0) 0C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020 - 04"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (20,0 – 60,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (20,0 – 70,0) 0C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04 Srodowisko pracy − mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (20,0 – 60,0) 0C\nTemperatura wilgotna naturalna\nZakres (15,0 – 50,0) 0C\nTemperatura poczernionej kuli\nZakres (20,0 – 70,0) 0C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(20,0 – 60,0) 0C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15,0 – 50,0) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(20,0 – 70,0) 0C"}],"search_en":"Workplace environment − hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(20,0 – 60,0) 0C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15,0 – 50,0) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(20,0 – 70,0) 0C"}],"search_zh":"工作场所环境 − 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a83b130af14b9c0e7b2079a","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy − mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020 - 04"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04 Srodowisko pracy − mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","test_object_en":"Workplace environment − hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 − 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020 - 04","test_object_zh":"工作场所环境 − 高温微气候"},{"_id":"6a83b130af14b9c0e7b2079b","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,0316 – 35,5) m/s²"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników","range":"(1.4awx, 1.4awy, awz)"},{"name":"(z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia; Metoda próbkowania","techniques":["Metoda pomiarowa bezpośrednia","Metoda próbkowania"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,0316 – 35,5) m/s²\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia; Metoda próbkowania","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,0316 – 35,5) m/s²\nEkspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia; Metoda próbkowania PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,0316 – 35,5) m/s²\nEkspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\nEkspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)\n(z obliczen)\nMetoda pomiarowa bezposrednia; Metoda probkowania PN-EN 14253+A1:2011","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,0316 – 35,5) m/s²"},{"name":"Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors","range":"(1.4awx, 1.4awy, awz)"},{"name":"Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors","range":"(1.4awx, 1.4awy, awz)"},{"name":"(calculated)"}],"search_en":"Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method; Sampling method Range Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for the three directional components, taking into account the relevant factors (calculated) PN-EN 14253+A1:2011","technique_en":"Direct measurement method; Sampling method","test_object_en":"Workplace environment − whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,0316 – 35,5) m/s²"},{"name":"日暴露量，以考虑相应系数后三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示","range":"(1.4awx, 1.4awy, awz)"},{"name":"持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度表示","range":"(1.4awx, 1.4awy, awz)"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 − 全身振动 频率计权振动加速度有效值 直接测量法；采样法 范围 日暴露量，以考虑相应系数后三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示 持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量所测定的振动加速度中占主导的频率计权有效振动加速度表示 （计算得出） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 − 全身振动","technique_zh":"直接测量法；采样法"},{"_id":"6a83b130af14b9c0e7b2079c","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,501 – 50,0) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"(z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia; Metoda próbkowania","techniques":["Metoda pomiarowa bezpośrednia","Metoda próbkowania"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,501 – 50,0) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia; Metoda próbkowania","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Pracownia Fizyczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres:\nZakres (0,501 – 50,0) m/s2\nEkspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)\n(z obliczeń)\nMetoda pomiarowa bezpośrednia; Metoda próbkowania PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres:\nZakres (0,501 – 50,0) m/s2\nEkspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)\nEkspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)\n(z obliczen)\nMetoda pomiarowa bezposrednia; Metoda probkowania PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,501 – 50,0) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"(calculated)"}],"search_en":"Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method; Sampling method Range (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method; Sampling method","test_object_en":"Workplace environment − hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,501 – 50,0) m/s2"},{"name":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych","range":"(ahwx, ahwy, ahwz)"},{"name":"（计算得出）"}],"search_zh":"工作场所环境 − 手传振动 频率计权振动加速度有效值 直接测量法；采样法 范围 （计算得出） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 − 手传振动","technique_zh":"直接测量法；采样法"},{"_id":"6a83b130af14b9c0e7b2079d","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"azbest – włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"},{"name":"sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nsztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"asbestos – respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"},{"name":"man-made mineral fibres excluding refractory ceramic fibres – respirable fibres"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres excluding refractory ceramic fibres – respirable fibres PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 石棉 — 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"石棉 — 呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"}]},{"_id":"6a83b130af14b9c0e7b2079e","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nsubstancje nieorganiczne\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method inorganic substances PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 无机物质 PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"无机物质"}],"technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a83b130af14b9c0e7b2079f","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b130af14b9c0e7b207a0","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,20 – 17,01) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,20 – 17,01) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,20 – 17,01) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nZakres (0,20 – 17,01) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"natural graphite"},{"name":"synthetic graphite"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"carbon black"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"silicon carbide, non-fibrous"},{"name":"Range","range":"(0,20 – 17,01) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,20 – 17,01) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a83b130af14b9c0e7b207a1","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,09 – 25,42) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,09 – 25,42) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,09 – 25,42) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,09 – 25,42) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,09 – 25,42) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,09 – 25,42) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a83b130af14b9c0e7b207a2","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku azotu","parameters":[{"name":"Zakres","range":"(0,25 –12,50) mg/m3"},{"name":"Zakres","range":"(0,2 – 10,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku azotu\nZakres:\nZakres (0,25 –12,50) mg/m3\nZakres (0,2 – 10,0) ppm\nMetoda elektrochemiczna","reference":"PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","norm_bases":["PB-01/PCH Wydanie 6 z dnia 18.03.2024 r."],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku azotu\nZakres:\nZakres (0,25 –12,50) mg/m3\nZakres (0,2 – 10,0) ppm\nMetoda elektrochemiczna PB-01/PCH Wydanie 6 z dnia 18.03.2024 r. Srodowisko pracy - powietrze Stezenie tlenku azotu\nZakres:\nZakres (0,25 –12,50) mg/m3\nZakres (0,2 – 10,0) ppm\nMetoda elektrochemiczna PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen oxide concentration","parameters_en":[{"name":"Range","range":"(0,25 –12,50) mg/m3"},{"name":"Range","range":"(0,2 – 10,0) ppm"}],"search_en":"Workplace environment - air Nitrogen oxide concentration Electrochemical method Range Range PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,25 –12,50) mg/m3"},{"name":"范围","range":"(0,2 – 10,0) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化氮浓度 电化学法 范围 范围 PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化氮浓度"},{"_id":"6a83b130af14b9c0e7b207a3","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,38 – 5,73) mg/m3"},{"name":"Zakres","range":"(0,2 – 3,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie ditlenku azotu\nZakres:\nZakres (0,38 – 5,73) mg/m3\nZakres (0,2 – 3,0) ppm\nMetoda elektrochemiczna","reference":"PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","norm_bases":["PB-01/PCH Wydanie 6 z dnia 18.03.2024 r."],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie ditlenku azotu\nZakres:\nZakres (0,38 – 5,73) mg/m3\nZakres (0,2 – 3,0) ppm\nMetoda elektrochemiczna PB-01/PCH Wydanie 6 z dnia 18.03.2024 r. Srodowisko pracy - powietrze Stezenie ditlenku azotu\nZakres:\nZakres (0,38 – 5,73) mg/m3\nZakres (0,2 – 3,0) ppm\nMetoda elektrochemiczna PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide concentration","parameters_en":[{"name":"Range","range":"(0,38 – 5,73) mg/m3"},{"name":"Range","range":"(0,2 – 3,0) ppm"}],"search_en":"Workplace environment - air Nitrogen dioxide concentration Electrochemical method Range Range PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,38 – 5,73) mg/m3"},{"name":"范围","range":"(0,2 – 3,0) ppm"}],"search_zh":"工作场所环境 — 空气 二氧化氮浓度 电化学法 范围 范围 PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"二氧化氮浓度"},{"_id":"6a83b130af14b9c0e7b207a4","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 162,4) mg/m3"},{"name":"Zakres","range":"(2 – 140) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 162,4) mg/m3\nZakres (2 – 140) ppm\nMetoda elektrochemiczna","reference":"PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","norm_bases":["PB-01/PCH Wydanie 6 z dnia 18.03.2024 r."],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 162,4) mg/m3\nZakres (2 – 140) ppm\nMetoda elektrochemiczna PB-01/PCH Wydanie 6 z dnia 18.03.2024 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 162,4) mg/m3\nZakres (2 – 140) ppm\nMetoda elektrochemiczna PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 162,4) mg/m3"},{"name":"Range","range":"(2 – 140) ppm"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range Range PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(2,3 – 162,4) mg/m3"},{"name":"范围","range":"(2 – 140) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a83b130af14b9c0e7b207a5","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","norm_bases":["PB-01/PCH Wydanie 6 z dnia 18.03.2024 r."],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB-01/PCH Wydanie 6 z dnia 18.03.2024 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-01/PCH Wydanie 6 z dnia 18.03.2024 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a83b130af14b9c0e7b207a6","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie/Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,05 – 20,0) mg/m3"},{"name":"Zakres","range":"(0,02 – 0,4) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/Zawartość chlorowodoru\nZakres:\nZakres (0,05 – 20,0) mg/m3\nZakres (0,02 – 0,4) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie/Zawartość chlorowodoru\nZakres:\nZakres (0,05 – 20,0) mg/m3\nZakres (0,02 – 0,4) mg w próbce\nMetoda spektrofotometryczna PN-Z-04450:2014-08 Srodowisko pracy - powietrze Stezenie/Zawartosc chlorowodoru\nZakres:\nZakres (0,05 – 20,0) mg/m3\nZakres (0,02 – 0,4) mg w probce\nMetoda spektrofotometryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,05 – 20,0) mg/m3"},{"name":"Range","range":"(0,02 – 0,4) mg w próbce"}],"search_en":"Workplace environment - air Hydrogen chloride concentration/content Spectrophotometric method Range Range PN-Z-04450:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,05 – 20,0) mg/m3"},{"name":"范围","range":"(0,02 – 0,4) mg w próbce"}],"search_zh":"工作场所环境 — 空气 氯化氢的浓度/含量 分光光度法 范围 范围 PN-Z-04450:2014-08","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a83b130af14b9c0e7b207a7","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie/Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) mg/m3"},{"name":"Zakres","range":"(0,03 – 0,30) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/Zawartość amoniaku\nZakres:\nZakres (1,0 – 60,0) mg/m3\nZakres (0,03 – 0,30) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie/Zawartość amoniaku\nZakres:\nZakres (1,0 – 60,0) mg/m3\nZakres (0,03 – 0,30) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy - powietrze Stezenie/Zawartosc amoniaku\nZakres:\nZakres (1,0 – 60,0) mg/m3\nZakres (0,03 – 0,30) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/Content of ammonia","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) mg/m3"},{"name":"Range","range":"(0,03 – 0,30) mg w próbce"}],"search_en":"Workplace environment - air Concentration/Content of ammonia Spectrophotometric method Range Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) mg/m3"},{"name":"范围","range":"(0,03 – 0,30) mg w próbce"}],"search_zh":"工作场所环境 — 空气 氨的浓度/含量 分光光度法 范围 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氨的浓度/含量"},{"_id":"6a83b130af14b9c0e7b207a8","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza","methodology":"Stężenie/zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,4 – 12,0) mg/m3"},{"name":"Zakres","range":"(0,25 – 8,10) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,4 – 12,0) mg/m3\nZakres (0,25 – 8,10) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"PN-Z-04108-5:2006","norm_bases":["PN-Z-04108-5:2006"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza Stężenie/zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,4 – 12,0) mg/m3\nZakres (0,25 – 8,10) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR) PN-Z-04108-5:2006 Srodowisko pracy - powietrze - probki powietrza Stezenie/zawartosc olejow mineralnych wysokorafinowanych z wylaczeniem cieczy obrobkowych\nZakres:\nfrakcja wdychalna\nZakres (0,4 – 12,0) mg/m3\nZakres (0,25 – 8,10) mg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT-IR) PN-Z-04108-5:2006","categories":["environment","petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of highly refined mineral oils excluding metalworking fluids","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,4 – 12,0) mg/m3"},{"name":"Range","range":"(0,25 – 8,10) mg w próbce"}],"search_en":"Workplace environment - air - air samples Concentration/content of highly refined mineral oils excluding metalworking fluids Fourier transform infrared spectrometry (FT-IR) inhalable fraction Range Range PN-Z-04108-5:2006","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment - air - air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,4 – 12,0) mg/m3"},{"name":"范围","range":"(0,25 – 8,10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 傅里叶变换红外光谱法（FT-IR） 可吸入组分 范围 范围 PN-Z-04108-5:2006","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a83b130af14b9c0e7b207a9","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza","methodology":"Stężenie/zawartość krzemionki krystalicznej – kwarc, krystobalit","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,010 – 0,73) mg/m3"},{"name":"Zakres","range":"(0,0068 – 0,500) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie/zawartość krzemionki krystalicznej – kwarc, krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,010 – 0,73) mg/m3\nZakres (0,0068 – 0,500) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza Stężenie/zawartość krzemionki krystalicznej – kwarc, krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,010 – 0,73) mg/m3\nZakres (0,0068 – 0,500) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130 Srodowisko pracy - powietrze - probki powietrza Stezenie/zawartosc krzemionki krystalicznej – kwarc, krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,010 – 0,73) mg/m3\nZakres (0,0068 – 0,500) mg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4 (74), s. 117-130","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of crystalline silica – quartz, cristobalite","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,010 – 0,73) mg/m3"},{"name":"Range","range":"(0,0068 – 0,500) mg w próbce"}],"search_en":"Workplace environment - air - air samples Concentration/content of crystalline silica – quartz, cristobalite Fourier transform infrared spectrometry (FT-IR) respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment - air - air samples","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,010 – 0,73) mg/m3"},{"name":"范围","range":"(0,0068 – 0,500) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 傅里叶变换红外光谱法（FT-IR） 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4 (74), s. 117-130","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a83b130af14b9c0e7b207aa","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza","methodology":"Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,010 – 0,42) mg/m3"},{"name":"Zakres","range":"(0,0075 – 0,300) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0047 – 0,19) mg/m3"},{"name":"Zakres","range":"(0,00375 – 0,1500) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,010 – 0,42) mg/m3\nZakres (0,0075 – 0,300) mg w próbce\nfrakcja respirabilna\nZakres (0,0047 – 0,19) mg/m3\nZakres (0,00375 – 0,1500) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10 + Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10 + Ap1:2015-12"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza Stężenie/zawartość manganu i jego związków nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,010 – 0,42) mg/m3\nZakres (0,0075 – 0,300) mg w próbce\nfrakcja respirabilna\nZakres (0,0047 – 0,19) mg/m3\nZakres (0,00375 – 0,1500) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 + Ap1:2015-12 Srodowisko pracy - powietrze - probki powietrza Stezenie/zawartosc manganu i jego zwiazkow nieorganicznych – w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,010 – 0,42) mg/m3\nZakres (0,0075 – 0,300) mg w probce\nfrakcja respirabilna\nZakres (0,0047 – 0,19) mg/m3\nZakres (0,00375 – 0,1500) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10 + Ap1:2015-12","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of manganese and its inorganic compounds – expressed as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,010 – 0,42) mg/m3"},{"name":"Range","range":"(0,0075 – 0,300) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,0047 – 0,19) mg/m3"},{"name":"Range","range":"(0,00375 – 0,1500) mg w próbce"}],"search_en":"Workplace environment - air - air samples Concentration/content of manganese and its inorganic compounds – expressed as Mn Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-Z-04472:2015-10 + Ap1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,010 – 0,42) mg/m3"},{"name":"范围","range":"(0,0075 – 0,300) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0047 – 0,19) mg/m3"},{"name":"范围","range":"(0,00375 – 0,1500) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 锰及其无机化合物的浓度/含量 － 以 Mn 计 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04472:2015-10 + Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"锰及其无机化合物的浓度/含量 － 以 Mn 计"},{"_id":"6a83b130af14b9c0e7b207ab","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza","methodology":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,017 – 0,43) mg/m3"},{"name":"Zakres","range":"(0,0125 – 0,312) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,017 – 0,43) mg/m3\nZakres (0,0125 – 0,312) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04106-3:2002","norm_bases":["PN-Z-04106-3:2002"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,017 – 0,43) mg/m3\nZakres (0,0125 – 0,312) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-3:2002 Srodowisko pracy - powietrze - probki powietrza Stezenie/zawartosc miedzi i jej zwiazkow nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,017 – 0,43) mg/m3\nZakres (0,0125 – 0,312) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-3:2002","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of copper and its inorganic compounds – calculated as Cu","parameters_en":[{"name":"Range","range":"(0,017 – 0,43) mg/m3"},{"name":"Range","range":"(0,0125 – 0,312) mg w próbce"}],"search_en":"Workplace environment - air - air samples Concentration/content of copper and its inorganic compounds – calculated as Cu Flame atomic absorption spectrometry (FAAS) Range Range PN-Z-04106-3:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples","parameters_zh":[{"name":"范围","range":"(0,017 – 0,43) mg/m3"},{"name":"范围","range":"(0,0125 – 0,312) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 铜及其无机化合物的浓度/含量 － 以 Cu 计 火焰原子吸收光谱法（FAAS） 范围 范围 PN-Z-04106-3:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"铜及其无机化合物的浓度/含量 － 以 Cu 计"},{"_id":"6a83b130af14b9c0e7b207ac","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza","methodology":"Stężenie/zawartość tlenku cynku – w przeliczeniu na Zn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,35 – 20,8) mg/m3"},{"name":"Zakres","range":"(0,25 – 12,5) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenku cynku – w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,35 – 20,8) mg/m3\nZakres (0,25 – 12,5) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04100-3:1987","norm_bases":["PN-Z-04100-3:1987"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza Stężenie/zawartość tlenku cynku – w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,35 – 20,8) mg/m3\nZakres (0,25 – 12,5) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04100-3:1987 Srodowisko pracy - powietrze - probki powietrza Stezenie/zawartosc tlenku cynku – w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,35 – 20,8) mg/m3\nZakres (0,25 – 12,5) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04100-3:1987","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of zinc oxide – calculated as Zn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,35 – 20,8) mg/m3"},{"name":"Range","range":"(0,25 – 12,5) mg w próbce"}],"search_en":"Workplace environment - air - air samples Concentration/content of zinc oxide – calculated as Zn Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range PN-Z-04100-3:1987","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,35 – 20,8) mg/m3"},{"name":"范围","range":"(0,25 – 12,5) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 PN-Z-04100-3:1987","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83b130af14b9c0e7b207ad","lab_id":"69ad52a3de79e566650fb422","country":"PL","accr_number":"AB 821","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza","methodology":"Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,43 – 22,7) mg/m3"},{"name":"Zakres","range":"(0,312 – 9,375) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,20 – 11,4) mg/m3"},{"name":"Zakres","range":"(0,156 – 4,688) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,43 – 22,7) mg/m3\nZakres (0,312 – 9,375) mg w próbce\nfrakcja respirabilna\nZakres (0,20 – 11,4) mg/m3\nZakres (0,156 – 4,688) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Pracownia Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza Stężenie/zawartość tlenków żelaza – w przeliczeniu na Fe Tlenek żelaza (III) Tlenek żelaza (II) Tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,43 – 22,7) mg/m3\nZakres (0,312 – 9,375) mg w próbce\nfrakcja respirabilna\nZakres (0,20 – 11,4) mg/m3\nZakres (0,156 – 4,688) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy - powietrze - probki powietrza Stezenie/zawartosc tlenkow zelaza – w przeliczeniu na Fe Tlenek zelaza (III) Tlenek zelaza (II) Tetratlenek trizelaza\nZakres:\nfrakcja wdychalna\nZakres (0,43 – 22,7) mg/m3\nZakres (0,312 – 9,375) mg w probce\nfrakcja respirabilna\nZakres (0,20 – 11,4) mg/m3\nZakres (0,156 – 4,688) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of iron oxides – calculated as Fe Iron(III) oxide Iron(II) oxide Triiron tetraoxide","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,43 – 22,7) mg/m3"},{"name":"Range","range":"(0,312 – 9,375) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,20 – 11,4) mg/m3"},{"name":"Range","range":"(0,156 – 4,688) mg w próbce"}],"search_en":"Workplace environment - air - air samples Concentration/content of iron oxides – calculated as Fe Iron(III) oxide Iron(II) oxide Triiron tetraoxide Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-Z-04469:2025-02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,43 – 22,7) mg/m3"},{"name":"范围","range":"(0,312 – 9,375) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,20 – 11,4) mg/m3"},{"name":"范围","range":"(0,156 – 4,688) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 空气样品"}],"has_pdf":true}