{"lab":{"_id":"69ad52a3de79e566650fb41a","accr_number":"AB 817","country":"PL","accr_body":"PCA","address":"LABORATORIUM, ul. Srebrna 172/188, 42-202 Częstochowa","categories":["water","environment","materials"],"city":"Częstochowa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":40,"name":"OCZYSZCZALNIA ŚCIEKÓW „WARTA” S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_817.pdf"],"scope_summary":"","search_text":"oczyszczalnia ścieków „warta” s.a. laboratorium, ul. srebrna 172/188, 42-202 częstochowa water other pharma materials environment","status":"active","updated_at":"2026-03-08T14:51:42.204Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:12:07.023Z","location":{"type":"Point","coordinates":[19.1203,50.8118]},"email_confidence":"high","email_mx":true,"email_source":"https://www.wartasa.eu/1,Kontakt","fields_of_testing":[{"codes":"C/32","pl":"Badania chemiczne, osadów, odpadów","en":"Chemical tests of sediments, waste"},{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"N/32","pl":"Badania właściwości fizycznych, osadów, odpadów","en":"Tests of physical properties of sediments, waste"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"}],"issue":{"no":"19","date":"03.07.2026"},"parse_date":"2026-08-18T01:12:07.023Z","parse_source":"agent-claude-code","map_coord":[50.818218,19.163808],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":"ul. Srebrna 172/188","city":"Częstochowa","postal":"42-202"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/71d8df3ed0d8e2fc518acc02b7614cc3/AB%20817.pdf","has_en":true,"category_counts":{"water":35,"environment":6,"materials":3},"category_scores":{"water":27.84,"environment":0.82,"materials":0.2},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":"ul. Srebrna 172/188","city":"Częstochowa","postal":"42-202"}]},"methods":[{"_id":"6a83b167af14b9c0e7b207bb","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a83b167af14b9c0e7b207bc","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PA-03/2 wydanie z dnia 05.05.2011 r.","norm_bases":["PA-03/2 wydanie z dnia 05.05.2011 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (1,0 – 50,0) °C PA-03/2 wydanie z dnia 05.05.2011 r. Scieki Temperatura\nZakres (1,0 – 50,0) °C PA-03/2 wydanie z dnia 05.05.2011 r.","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Wastewater Temperature Laboratory Range PA-03/2 wydanie z dnia 05.05.2011 r.","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"污水 温度 实验室 范围 PA-03/2 wydanie z dnia 05.05.2011 r.","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a83b167af14b9c0e7b207bd","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wył. p. 5.2; 6.1.2, 6.2 i 6.3","norm_bases":["PN-ISO 5667-11:2017-10 z wył. p. 5.2; 6.1.2, 6.2 i 6.3"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wył. p. 5.2; 6.1.2, 6.2 i 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyl. p. 5.2; 6.1.2, 6.2 i 6.3","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing Laboratory PN-ISO 5667-11:2017-10 z wył. p. 5.2; 6.1.2, 6.2 i 6.3","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 实验室 PN-ISO 5667-11:2017-10 z wył. p. 5.2; 6.1.2, 6.2 i 6.3","test_object_zh":"水"},{"_id":"6a83b167af14b9c0e7b207be","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) °C","reference":"PA-03/2 wydanie z dnia 05.05.2011 r.","norm_bases":["PA-03/2 wydanie z dnia 05.05.2011 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (1,0 – 50,0) °C PA-03/2 wydanie z dnia 05.05.2011 r. Woda Temperatura\nZakres (1,0 – 50,0) °C PA-03/2 wydanie z dnia 05.05.2011 r.","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"search_en":"Water Temperature Laboratory Range PA-03/2 wydanie z dnia 05.05.2011 r.","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"水 温度 实验室 范围 PA-03/2 wydanie z dnia 05.05.2011 r.","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a83b167af14b9c0e7b207bf","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie krzemu ogólnego","parameters":[{"name":"Zakres","range":"(0,005 – 100) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie krzemu ogólnego\nZakres (0,005 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie krzemu ogólnego\nZakres (0,005 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie krzemu ogolnego\nZakres (0,005 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total silicon concentration","parameters_en":[{"name":"Range","range":"(0,005 – 100) mg/l"}],"search_en":"Water Total silicon concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Laboratory Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,005 – 100) mg/l"}],"search_zh":"水 电感耦合等离子体原子发射光谱法（ICP-OES） 实验室 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水"},{"_id":"6a83b167af14b9c0e7b207c0","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"Water, Wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"水、污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c1","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 200) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 200) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c2","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08 z wyłączeniem p. 9","norm_bases":["PN-82/C-04576.08 z wyłączeniem p. 9"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,20 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 z wyłączeniem p. 9 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,20 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 z wylaczeniem p. 9","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 20) mg/l"}],"search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Laboratory Range PN-82/C-04576.08 z wyłączeniem p. 9","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 20) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 实验室 范围 PN-82/C-04576.08 z wyłączeniem p. 9","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c3","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(3,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (3,00 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,00 – 1000) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(3,00 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c4","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PA-01/2 wydanie z dnia 05.05.2011 r.","norm_bases":["PA-01/2 wydanie z dnia 05.05.2011 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 20) mg/l\nMetoda spektrofotometryczna PA-01/2 wydanie z dnia 05.05.2011 r. Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 20) mg/l\nMetoda spektrofotometryczna PA-01/2 wydanie z dnia 05.05.2011 r.","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 20) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Spectrophotometric method Laboratory Range PA-01/2 wydanie z dnia 05.05.2011 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 20) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 分光光度法 实验室 范围 PA-01/2 wydanie z dnia 05.05.2011 r.","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c5","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 1) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 1) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,010 – 1) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,010 – 1) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 1) mg/l"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 1) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c6","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PA-04/2 wydanie z dnia 05.05.2011 r.","norm_bases":["PA-04/2 wydanie z dnia 05.05.2011 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PA-04/2 wydanie z dnia 05.05.2011 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PA-04/2 wydanie z dnia 05.05.2011 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) Laboratory PA-04/2 wydanie z dnia 05.05.2011 r.","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） 实验室 PA-04/2 wydanie z dnia 05.05.2011 r.","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c7","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (związanego)","parameters":[{"name":"Zakres","range":"(1,00 – 1000) mg/l"},{"name":"Stężenie rozpuszczonego azotu ogólnego (związanego)"},{"name":"Zakres","range":"(1,00 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"computed":[],"activity":"Stężenie azotu ogólnego (związanego)\nZakres:\nZakres (1,00 – 1000) mg/l\nStężenie rozpuszczonego azotu ogólnego (związanego)\nZakres (1,00 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-05","norm_bases":["PN-EN ISO 20236:2025-05"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (związanego)\nZakres:\nZakres (1,00 – 1000) mg/l\nStężenie rozpuszczonego azotu ogólnego (związanego)\nZakres (1,00 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-05 Woda, Scieki Stezenie azotu ogolnego (zwiazanego)\nZakres:\nZakres (1,00 – 1000) mg/l\nStezenie rozpuszczonego azotu ogolnego (zwiazanego)\nZakres (1,00 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-05","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total (bound) nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,00 – 1000) mg/l"},{"name":"Dissolved total (bound) nitrogen concentration"},{"name":"Range","range":"(1,00 – 1000) mg/l"}],"search_en":"Water, Wastewater Total (bound) nitrogen concentration High-temperature combustion with chemiluminescence detection Laboratory Range Dissolved total (bound) nitrogen concentration Range PN-EN ISO 20236:2025-05","technique_en":"High-temperature combustion with chemiluminescence detection","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,00 – 1000) mg/l"},{"name":"Stężenie rozpuszczonego azotu ogólnego (związanego)"},{"name":"范围","range":"(1,00 – 1000) mg/l"}],"search_zh":"水、污水 高温燃烧-化学发光检测法 实验室 范围 范围 PN-EN ISO 20236:2025-05","test_object_zh":"水、污水","technique_zh":"高温燃烧-化学发光检测法"},{"_id":"6a83b167af14b9c0e7b207c8","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207c9","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,70 – 6) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,70 – 6) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,70 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,70 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,70 – 6) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,70 – 6) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207ca","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(5,0 – 15 000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,0 – 15 000) mg/l O2\nMetoda miareczkowa","reference":"PN-74/C-04578.03","norm_bases":["PN-74/C-04578.03"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,0 – 15 000) mg/l O2\nMetoda miareczkowa PN-74/C-04578.03 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5,0 – 15 000) mg/l O2\nMetoda miareczkowa PN-74/C-04578.03","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(5,0 – 15 000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand Titrimetric method Laboratory COD-Cr Range PN-74/C-04578.03","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(5,0 – 15 000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 滴定法 实验室 化学需氧量（COD-Cr） 范围 PN-74/C-04578.03","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a83b167af14b9c0e7b207cb","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(20,0 – 20 000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20,0 – 20 000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20,0 – 20 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (20,0 – 20 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(20,0 – 20 000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand Titrimetric method Laboratory COD-Cr Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(20,0 – 20 000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 滴定法 实验室 化学需氧量（COD-Cr） 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a83b167af14b9c0e7b207cc","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,00 – 1000) mg/l"},{"name":"Stężenie rozpuszczonego węgla organicznego (RWO)"},{"name":"Zakres","range":"(1,00 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres:\nZakres (1,00 – 1000) mg/l\nStężenie rozpuszczonego węgla organicznego (RWO)\nZakres (1,00 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres:\nZakres (1,00 – 1000) mg/l\nStężenie rozpuszczonego węgla organicznego (RWO)\nZakres (1,00 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres:\nZakres (1,00 – 1000) mg/l\nStezenie rozpuszczonego wegla organicznego (RWO)\nZakres (1,00 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,00 – 1000) mg/l"},{"name":"Dissolved organic carbon (DOC) concentration"},{"name":"Range","range":"(1,00 – 1000) mg/l"}],"search_en":"Water, Wastewater Total organic carbon concentration (TOC) High-temperature combustion with IR detection Laboratory Range Dissolved organic carbon (DOC) concentration Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,00 – 1000) mg/l"},{"name":"溶解性有机碳（DOC）浓度"},{"name":"范围","range":"(1,00 – 1000) mg/l"}],"search_zh":"水、污水 总有机碳浓度（TOC） 高温燃烧红外检测法 实验室 范围 溶解性有机碳（DOC）浓度 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、污水","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a83b167af14b9c0e7b207cd","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Gravimetric method Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207ce","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,00 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 1000) mg/l"}],"search_en":"Water, Wastewater Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 1000) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207cf","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10,0 – 8000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone Sucha pozostałość\nZakres (10,0 – 8000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone Sucha pozostałość\nZakres (10,0 – 8000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, Scieki Substancje rozpuszczone Sucha pozostalosc\nZakres (10,0 – 8000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dissolved solids Dry residue","parameters_en":[{"name":"Range","range":"(10,0 – 8000) mg/l"}],"search_en":"Water, Wastewater Dissolved solids Dry residue Gravimetric method Laboratory Range PN-78/C-04541","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10,0 – 8000) mg/l"}],"search_zh":"水、污水 重量法 实验室 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207d0","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zasadowość ogólna Zasadowość złożona","parameters":[{"name":"Zakres","range":"(0,40 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna Zasadowość złożona\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zasadowość ogólna Zasadowość złożona\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Scieki Zasadowosc ogolna Zasadowosc zlozona\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total alkalinity Composite alkalinity","parameters_en":[{"name":"Range","range":"(0,40 – 20) mmol/l"}],"search_en":"Water, Wastewater Total alkalinity Composite alkalinity Titrimetric method Laboratory Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,40 – 20) mmol/l"}],"search_zh":"水、污水 滴定法 实验室 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207d1","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207d2","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050 – 50) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 50) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207d3","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573.01","norm_bases":["PN-86/C-04573.01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-86/C-04573.01 Woda, Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-86/C-04573.01","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Laboratory Range PN-86/C-04573.01","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、污水 石油醚可萃取物浓度 重量法 实验室 范围 PN-86/C-04573.01","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a83b167af14b9c0e7b207d4","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie cyjanków wolnych, związanych i ogólnych","parameters":[{"name":"Zakres","range":"(0,005 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków wolnych, związanych i ogólnych\nZakres (0,005 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-80/C-04603.01","norm_bases":["PN-80/C-04603.01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie cyjanków wolnych, związanych i ogólnych\nZakres (0,005 – 30) mg/l\nMetoda spektrofotometryczna PN-80/C-04603.01 Woda, Scieki Stezenie cyjankow wolnych, zwiazanych i ogolnych\nZakres (0,005 – 30) mg/l\nMetoda spektrofotometryczna PN-80/C-04603.01","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of free, bound and total cyanides","parameters_en":[{"name":"Range","range":"(0,005 – 30) mg/l"}],"search_en":"Water, Wastewater Concentration of free, bound and total cyanides Spectrophotometric method Laboratory Range PN-80/C-04603.01","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,005 – 30) mg/l"}],"search_zh":"水、污水 分光光度法 实验室 范围 PN-80/C-04603.01","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207d5","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,005 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,005 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,005 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, Scieki Indeks fenolowy\nZakres (0,005 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,005 – 50) mg/l"}],"search_en":"Water, Wastewater Phenol index Spectrophotometric method Laboratory Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,005 – 50) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 实验室 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a83b167af14b9c0e7b207d6","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"antymon","range":"(0,0050 – 20) mg/l"},{"name":"arsen","range":"(0,0030 – 20) mg/l"},{"name":"bar","range":"(0,0050 – 20) mg/l"},{"name":"bor","range":"(0,010 – 20) mg/l"},{"name":"chrom","range":"(0,005 – 20) mg/l"},{"name":"cyna","range":"(0,0050 – 20) mg/l"},{"name":"cynk","range":"(0,0050 – 30) mg/l"},{"name":"fosfor","range":"(0,010 – 100) mg/l"},{"name":"glin","range":"(0,010 – 20) mg/l"},{"name":"kadm","range":"(0,00050 – 20 mg/l"},{"name":"kobalt","range":"(0,0010 – 20) mg/l"},{"name":"magnez","range":"(0,100 – 20) mg/l"},{"name":"mangan","range":"(0,010 – 20) mg/l"},{"name":"miedź","range":"(0,0030 – 20) mg/l"},{"name":"molibden","range":"(0,0050 – 20) mg/l"},{"name":"nikiel","range":"(0,0030 – 20) mg/l"},{"name":"ołów","range":"(0,0050 – 20) mg/l"},{"name":"rtęć","range":"(0,0050 – 5) mg/l"},{"name":"selen","range":"(0,010 – 20) mg/l"},{"name":"siarka","range":"(0,050 – 100) mg/l"},{"name":"srebro","range":"(0,0020 – 5) mg/l"},{"name":"stront","range":"(0,0050 – 20) mg/l"},{"name":"tal","range":"(0,0050 – 20) mg/l"},{"name":"wanad","range":"(0,0010 – 20) mg/l"},{"name":"wapń","range":"(0,100 – 200) mg/l"},{"name":"żelazo","range":"(0,010 – 20) mg/l"},{"name":"lit","range":"(0,010 – 20) mg/l"},{"name":"potas","range":"(0,200 – 10 000) mg/l"},{"name":"sód","range":"(1,00 – 10 000) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nantymon (0,0050 – 20) mg/l\narsen (0,0030 – 20) mg/l\nbar (0,0050 – 20) mg/l\nbor (0,010 – 20) mg/l\nchrom (0,005 – 20) mg/l\ncyna (0,0050 – 20) mg/l\ncynk (0,0050 – 30) mg/l\nfosfor (0,010 – 100) mg/l\nglin (0,010 – 20) mg/l\nkadm (0,00050 – 20 mg/l\nkobalt (0,0010 – 20) mg/l\nmagnez (0,100 – 20) mg/l\nmangan (0,010 – 20) mg/l\nmiedź (0,0030 – 20) mg/l\nmolibden (0,0050 – 20) mg/l\nnikiel (0,0030 – 20) mg/l\nołów (0,0050 – 20) mg/l\nrtęć (0,0050 – 5) mg/l\nselen (0,010 – 20) mg/l\nsiarka (0,050 – 100) mg/l\nsrebro (0,0020 – 5) mg/l\nstront (0,0050 – 20) mg/l\ntal (0,0050 – 20) mg/l\nwanad (0,0010 – 20) mg/l\nwapń (0,100 – 200) mg/l\nżelazo (0,010 – 20) mg/l\nlit (0,010 – 20) mg/l\npotas (0,200 – 10 000) mg/l\nsód (1,00 – 10 000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nantymon (0,0050 – 20) mg/l\narsen (0,0030 – 20) mg/l\nbar (0,0050 – 20) mg/l\nbor (0,010 – 20) mg/l\nchrom (0,005 – 20) mg/l\ncyna (0,0050 – 20) mg/l\ncynk (0,0050 – 30) mg/l\nfosfor (0,010 – 100) mg/l\nglin (0,010 – 20) mg/l\nkadm (0,00050 – 20 mg/l\nkobalt (0,0010 – 20) mg/l\nmagnez (0,100 – 20) mg/l\nmangan (0,010 – 20) mg/l\nmiedź (0,0030 – 20) mg/l\nmolibden (0,0050 – 20) mg/l\nnikiel (0,0030 – 20) mg/l\nołów (0,0050 – 20) mg/l\nrtęć (0,0050 – 5) mg/l\nselen (0,010 – 20) mg/l\nsiarka (0,050 – 100) mg/l\nsrebro (0,0020 – 5) mg/l\nstront (0,0050 – 20) mg/l\ntal (0,0050 – 20) mg/l\nwanad (0,0010 – 20) mg/l\nwapń (0,100 – 200) mg/l\nżelazo (0,010 – 20) mg/l\nlit (0,010 – 20) mg/l\npotas (0,200 – 10 000) mg/l\nsód (1,00 – 10 000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie pierwiastkow\nZakres:\nantymon (0,0050 – 20) mg/l\narsen (0,0030 – 20) mg/l\nbar (0,0050 – 20) mg/l\nbor (0,010 – 20) mg/l\nchrom (0,005 – 20) mg/l\ncyna (0,0050 – 20) mg/l\ncynk (0,0050 – 30) mg/l\nfosfor (0,010 – 100) mg/l\nglin (0,010 – 20) mg/l\nkadm (0,00050 – 20 mg/l\nkobalt (0,0010 – 20) mg/l\nmagnez (0,100 – 20) mg/l\nmangan (0,010 – 20) mg/l\nmiedz (0,0030 – 20) mg/l\nmolibden (0,0050 – 20) mg/l\nnikiel (0,0030 – 20) mg/l\nolow (0,0050 – 20) mg/l\nrtec (0,0050 – 5) mg/l\nselen (0,010 – 20) mg/l\nsiarka (0,050 – 100) mg/l\nsrebro (0,0020 – 5) mg/l\nstront (0,0050 – 20) mg/l\ntal (0,0050 – 20) mg/l\nwanad (0,0010 – 20) mg/l\nwapn (0,100 – 200) mg/l\nzelazo (0,010 – 20) mg/l\nlit (0,010 – 20) mg/l\npotas (0,200 – 10 000) mg/l\nsod (1,00 – 10 000) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Element concentration","parameters_en":[{"name":"antimony","range":"(0,0050 – 20) mg/l"},{"name":"arsenic","range":"(0,0030 – 20) mg/l"},{"name":"barium","range":"(0,0050 – 20) mg/l"},{"name":"boron","range":"(0,010 – 20) mg/l"},{"name":"chromium","range":"(0,005 – 20) mg/l"},{"name":"tin","range":"(0,0050 – 20) mg/l"},{"name":"zinc","range":"(0,0050 – 30) mg/l"},{"name":"phosphorus","range":"(0,010 – 100) mg/l"},{"name":"aluminium","range":"(0,010 – 20) mg/l"},{"name":"cadmium","range":"(0,00050 – 20 mg/l"},{"name":"cobalt","range":"(0,0010 – 20) mg/l"},{"name":"magnesium","range":"(0,100 – 20) mg/l"},{"name":"manganese","range":"(0,010 – 20) mg/l"},{"name":"copper","range":"(0,0030 – 20) mg/l"},{"name":"molybdenum","range":"(0,0050 – 20) mg/l"},{"name":"nickel","range":"(0,0030 – 20) mg/l"},{"name":"lead","range":"(0,0050 – 20) mg/l"},{"name":"mercury","range":"(0,0050 – 5) mg/l"},{"name":"selenium","range":"(0,010 – 20) mg/l"},{"name":"sulfur","range":"(0,050 – 100) mg/l"},{"name":"silver","range":"(0,0020 – 5) mg/l"},{"name":"strontium","range":"(0,0050 – 20) mg/l"},{"name":"thallium","range":"(0,0050 – 20) mg/l"},{"name":"vanadium","range":"(0,0010 – 20) mg/l"},{"name":"calcium","range":"(0,100 – 200) mg/l"},{"name":"iron","range":"(0,010 – 20) mg/l"},{"name":"lithium","range":"(0,010 – 20) mg/l"},{"name":"potassium","range":"(0,200 – 10 000) mg/l"},{"name":"sodium","range":"(1,00 – 10 000) mg/l"}],"search_en":"Water, Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Laboratory antimony arsenic barium boron chromium tin zinc phosphorus aluminium cadmium cobalt magnesium manganese copper molybdenum nickel lead mercury selenium sulfur silver strontium thallium vanadium calcium iron lithium potassium sodium PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"元素浓度","parameters_zh":[{"name":"锑","range":"(0,0050 – 20) mg/l"},{"name":"砷","range":"(0,0030 – 20) mg/l"},{"name":"钡","range":"(0,0050 – 20) mg/l"},{"name":"硼","range":"(0,010 – 20) mg/l"},{"name":"铬","range":"(0,005 – 20) mg/l"},{"name":"锡","range":"(0,0050 – 20) mg/l"},{"name":"锌","range":"(0,0050 – 30) mg/l"},{"name":"磷","range":"(0,010 – 100) mg/l"},{"name":"铝","range":"(0,010 – 20) mg/l"},{"name":"镉","range":"(0,00050 – 20 mg/l"},{"name":"钴","range":"(0,0010 – 20) mg/l"},{"name":"镁","range":"(0,100 – 20) mg/l"},{"name":"锰","range":"(0,010 – 20) mg/l"},{"name":"铜","range":"(0,0030 – 20) mg/l"},{"name":"钼","range":"(0,0050 – 20) mg/l"},{"name":"镍","range":"(0,0030 – 20) mg/l"},{"name":"铅","range":"(0,0050 – 20) mg/l"},{"name":"汞","range":"(0,0050 – 5) mg/l"},{"name":"硒","range":"(0,010 – 20) mg/l"},{"name":"硫","range":"(0,050 – 100) mg/l"},{"name":"银","range":"(0,0020 – 5) mg/l"},{"name":"锶","range":"(0,0050 – 20) mg/l"},{"name":"铊","range":"(0,0050 – 20) mg/l"},{"name":"钒","range":"(0,0010 – 20) mg/l"},{"name":"钙","range":"(0,100 – 200) mg/l"},{"name":"铁","range":"(0,010 – 20) mg/l"},{"name":"锂","range":"(0,010 – 20) mg/l"},{"name":"钾","range":"(0,200 – 10 000) mg/l"},{"name":"钠","range":"(1,00 – 10 000) mg/l"}],"search_zh":"水、污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 实验室 锑 砷 钡 硼 铬 锡 锌 磷 铝 镉 钴 镁 锰 铜 钼 镍 铅 汞 硒 硫 银 锶 铊 钒 钙 铁 锂 钾 钠 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a83b167af14b9c0e7b207d7","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość pierwiastków","parameters":[{"name":"arsen","range":"(1,00 – 300) mg/kg"},{"name":"chrom","range":"(1,00 – 1000) mg/kg"},{"name":"cynk","range":"(1,00 – 7000) mg/kg"},{"name":"cyna","range":"(1,00 – 200) mg/kg"},{"name":"fosfor","range":"(2,00 – 100000) mg/kg"},{"name":"glin","range":"(1,00 – 20000) mg/kg"},{"name":"kadm","range":"(0,50 – 150) mg/kg"},{"name":"kobalt","range":"(1,00 – 100) mg/kg"},{"name":"magnez","range":"(20 – 100000) mg/kg"},{"name":"miedź","range":"(1,00 – 800) mg/kg"},{"name":"molibden","range":"(1,00 – 150) mg/kg"},{"name":"nikiel","range":"(1,00 – 1000) mg/kg"},{"name":"ołów","range":"(1,00 – 500) mg/kg"},{"name":"rtęć","range":"(1,00 – 30) mg/kg"},{"name":"wanad","range":"(1,00 – 180) mg/kg"},{"name":"wapń","range":"(20 – 200000) mg/kg"},{"name":"antymon","range":"(1,00 – 150) mg/kg"},{"name":"selen","range":"(5,00 – 200) mg/kg"},{"name":"srebro","range":"(1,00 – 100) mg/kg"},{"name":"tal","range":"(1,00 – 170) mg/kg"},{"name":"mangan","range":"(1,00 – 850) mg/kg"},{"name":"żelazo","range":"(5,00 – 32000) mg/kg"},{"name":"potas","range":"(20 – 100 000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\narsen (1,00 – 300) mg/kg\nchrom (1,00 – 1000) mg/kg\ncynk (1,00 – 7000) mg/kg\ncyna (1,00 – 200) mg/kg\nfosfor (2,00 – 100000) mg/kg\nglin (1,00 – 20000) mg/kg\nkadm (0,50 – 150) mg/kg\nkobalt (1,00 – 100) mg/kg\nmagnez (20 – 100000) mg/kg\nmiedź (1,00 – 800) mg/kg\nmolibden (1,00 – 150) mg/kg\nnikiel (1,00 – 1000) mg/kg\nołów (1,00 – 500) mg/kg\nrtęć (1,00 – 30) mg/kg\nwanad (1,00 – 180) mg/kg\nwapń (20 – 200000) mg/kg\nantymon (1,00 – 150) mg/kg\nselen (5,00 – 200) mg/kg\nsrebro (1,00 – 100) mg/kg\ntal (1,00 – 170) mg/kg\nmangan (1,00 – 850) mg/kg\nżelazo (5,00 – 32000) mg/kg\npotas (20 – 100 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 22036:2024-07","norm_bases":["PN-EN ISO 22036:2024-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość pierwiastków\nZakres:\narsen (1,00 – 300) mg/kg\nchrom (1,00 – 1000) mg/kg\ncynk (1,00 – 7000) mg/kg\ncyna (1,00 – 200) mg/kg\nfosfor (2,00 – 100000) mg/kg\nglin (1,00 – 20000) mg/kg\nkadm (0,50 – 150) mg/kg\nkobalt (1,00 – 100) mg/kg\nmagnez (20 – 100000) mg/kg\nmiedź (1,00 – 800) mg/kg\nmolibden (1,00 – 150) mg/kg\nnikiel (1,00 – 1000) mg/kg\nołów (1,00 – 500) mg/kg\nrtęć (1,00 – 30) mg/kg\nwanad (1,00 – 180) mg/kg\nwapń (20 – 200000) mg/kg\nantymon (1,00 – 150) mg/kg\nselen (5,00 – 200) mg/kg\nsrebro (1,00 – 100) mg/kg\ntal (1,00 – 170) mg/kg\nmangan (1,00 – 850) mg/kg\nżelazo (5,00 – 32000) mg/kg\npotas (20 – 100 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 22036:2024-07 Osady sciekowe Zawartosc pierwiastkow\nZakres:\narsen (1,00 – 300) mg/kg\nchrom (1,00 – 1000) mg/kg\ncynk (1,00 – 7000) mg/kg\ncyna (1,00 – 200) mg/kg\nfosfor (2,00 – 100000) mg/kg\nglin (1,00 – 20000) mg/kg\nkadm (0,50 – 150) mg/kg\nkobalt (1,00 – 100) mg/kg\nmagnez (20 – 100000) mg/kg\nmiedz (1,00 – 800) mg/kg\nmolibden (1,00 – 150) mg/kg\nnikiel (1,00 – 1000) mg/kg\nolow (1,00 – 500) mg/kg\nrtec (1,00 – 30) mg/kg\nwanad (1,00 – 180) mg/kg\nwapn (20 – 200000) mg/kg\nantymon (1,00 – 150) mg/kg\nselen (5,00 – 200) mg/kg\nsrebro (1,00 – 100) mg/kg\ntal (1,00 – 170) mg/kg\nmangan (1,00 – 850) mg/kg\nzelazo (5,00 – 32000) mg/kg\npotas (20 – 100 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 22036:2024-07","categories":["water","materials"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Element content","parameters_en":[{"name":"arsenic","range":"(1,00 – 300) mg/kg"},{"name":"chromium","range":"(1,00 – 1000) mg/kg"},{"name":"zinc","range":"(1,00 – 7000) mg/kg"},{"name":"tin","range":"(1,00 – 200) mg/kg"},{"name":"phosphorus","range":"(2,00 – 100000) mg/kg"},{"name":"aluminium","range":"(1,00 – 20000) mg/kg"},{"name":"cadmium","range":"(0,50 – 150) mg/kg"},{"name":"cobalt","range":"(1,00 – 100) mg/kg"},{"name":"magnesium","range":"(20 – 100000) mg/kg"},{"name":"copper","range":"(1,00 – 800) mg/kg"},{"name":"molybdenum","range":"(1,00 – 150) mg/kg"},{"name":"nickel","range":"(1,00 – 1000) mg/kg"},{"name":"lead","range":"(1,00 – 500) mg/kg"},{"name":"mercury","range":"(1,00 – 30) mg/kg"},{"name":"vanadium","range":"(1,00 – 180) mg/kg"},{"name":"calcium","range":"(20 – 200000) mg/kg"},{"name":"antimony","range":"(1,00 – 150) mg/kg"},{"name":"selenium","range":"(5,00 – 200) mg/kg"},{"name":"silver","range":"(1,00 – 100) mg/kg"},{"name":"thallium","range":"(1,00 – 170) mg/kg"},{"name":"manganese","range":"(1,00 – 850) mg/kg"},{"name":"iron","range":"(5,00 – 32000) mg/kg"},{"name":"potassium","range":"(20 – 100 000) mg/kg"}],"search_en":"Sewage sludge Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Laboratory arsenic chromium zinc tin phosphorus aluminium cadmium cobalt magnesium copper molybdenum nickel lead mercury vanadium calcium antimony selenium silver thallium manganese iron potassium PN-EN ISO 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Sewage sludge","lab_section_zh":"实验室","methodology_zh":"元素含量","parameters_zh":[{"name":"砷","range":"(1,00 – 300) mg/kg"},{"name":"铬","range":"(1,00 – 1000) mg/kg"},{"name":"锌","range":"(1,00 – 7000) mg/kg"},{"name":"锡","range":"(1,00 – 200) mg/kg"},{"name":"磷","range":"(2,00 – 100000) mg/kg"},{"name":"铝","range":"(1,00 – 20000) mg/kg"},{"name":"镉","range":"(0,50 – 150) mg/kg"},{"name":"钴","range":"(1,00 – 100) mg/kg"},{"name":"镁","range":"(20 – 100000) mg/kg"},{"name":"铜","range":"(1,00 – 800) mg/kg"},{"name":"钼","range":"(1,00 – 150) mg/kg"},{"name":"镍","range":"(1,00 – 1000) mg/kg"},{"name":"铅","range":"(1,00 – 500) mg/kg"},{"name":"汞","range":"(1,00 – 30) mg/kg"},{"name":"钒","range":"(1,00 – 180) mg/kg"},{"name":"钙","range":"(20 – 200000) mg/kg"},{"name":"锑","range":"(1,00 – 150) mg/kg"},{"name":"硒","range":"(5,00 – 200) mg/kg"},{"name":"银","range":"(1,00 – 100) mg/kg"},{"name":"铊","range":"(1,00 – 170) mg/kg"},{"name":"锰","range":"(1,00 – 850) mg/kg"},{"name":"铁","range":"(5,00 – 32000) mg/kg"},{"name":"钾","range":"(20 – 100 000) mg/kg"}],"search_zh":"污泥 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 实验室 砷 铬 锌 锡 磷 铝 镉 钴 镁 铜 钼 镍 铅 汞 钒 钙 锑 硒 银 铊 锰 铁 钾 PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污泥"},{"_id":"6a83b167af14b9c0e7b207d8","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Sewage sludge pH – in H2O Potentiometric method Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"污泥 pH — 于 H2O 中 电位法 实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a83b167af14b9c0e7b207d9","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość (sucha masa) / zawartość wody","parameters":[{"name":"Zakres","range":"(0,2 – 99,8) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość (sucha masa) / zawartość wody\nZakres (0,2 – 99,8) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość (sucha masa) / zawartość wody\nZakres (0,2 – 99,8) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc (sucha masa) / zawartosc wody\nZakres (0,2 – 99,8) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,2 – 99,8) %"}],"search_en":"Sewage sludge Gravimetric method Laboratory Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,2 – 99,8) %"}],"search_zh":"污泥 重量法 实验室 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a83b167af14b9c0e7b207da","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Strata przy prażeniu (substancje organiczne)","parameters":[{"name":"Zakres","range":"(1,00 – 99,0) %"},{"name":"Pozostałość po prażeniu (substancje mineralne)"},{"name":"Zakres","range":"(1,00 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata przy prażeniu (substancje organiczne)\nZakres:\nZakres (1,00 – 99,0) %\nPozostałość po prażeniu (substancje mineralne)\nZakres (1,00 – 99,0) %\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Strata przy prażeniu (substancje organiczne)\nZakres:\nZakres (1,00 – 99,0) %\nPozostałość po prażeniu (substancje mineralne)\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 12879:2004 Osady sciekowe Strata przy prazeniu (substancje organiczne)\nZakres:\nZakres (1,00 – 99,0) %\nPozostalosc po prazeniu (substancje mineralne)\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 12879:2004","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Loss on ignition (organic matter)","parameters_en":[{"name":"Range","range":"(1,00 – 99,0) %"},{"name":"Residue on ignition (mineral substances)"},{"name":"Range","range":"(1,00 – 99,0) %"}],"search_en":"Sewage sludge Loss on ignition (organic matter) Gravimetric method Laboratory Range Residue on ignition (mineral substances) Range PN-EN 12879:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,00 – 99,0) %"},{"name":"Pozostałość po prażeniu (substancje mineralne)"},{"name":"范围","range":"(1,00 – 99,0) %"}],"search_zh":"污泥 烧失量（有机物质） 重量法 实验室 范围 范围 PN-EN 12879:2004","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"烧失量（有机物质）"},{"_id":"6a83b167af14b9c0e7b207db","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(1000 – 100 000) mg/kg"},{"name":"Zakres","range":"(0,10 – 10) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda spektrofotometryczna","reference":"PA-13/3 wydanie z dnia 30.12.2022 r.","norm_bases":["PA-13/3 wydanie z dnia 30.12.2022 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda spektrofotometryczna PA-13/3 wydanie z dnia 30.12.2022 r. Osady sciekowe Zawartosc fosforu ogolnego\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda spektrofotometryczna PA-13/3 wydanie z dnia 30.12.2022 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(1000 – 100 000) mg/kg"},{"name":"Range","range":"(0,10 – 10) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Laboratory Range Range PA-13/3 wydanie z dnia 30.12.2022 r.","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1000 – 100 000) mg/kg"},{"name":"范围","range":"(0,10 – 10) %"}],"search_zh":"污泥 总磷含量 分光光度法 实验室 范围 范围 PA-13/3 wydanie z dnia 30.12.2022 r.","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a83b167af14b9c0e7b207dc","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1000 – 100 000) mg/kg"},{"name":"Zakres","range":"(0,10 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(1000 – 100 000) mg/kg"},{"name":"Range","range":"(0,10 – 10) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Laboratory Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1000 – 100 000) mg/kg"},{"name":"范围","range":"(0,10 – 10) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 实验室 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a83b167af14b9c0e7b207dd","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. z 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 05 pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Odpady O) kod: 19 08 05 pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"pH Potentiometric method Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"pH 值 电位法 实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a83b167af14b9c0e7b207de","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Sucha pozostałość (sucha masa) / zawartość wody","parameters":[{"name":"Zakres","range":"(0,2 – 99,8) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość (sucha masa) / zawartość wody\nZakres (0,2 – 99,8) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. z 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Sucha pozostałość (sucha masa) / zawartość wody\nZakres (0,2 – 99,8) %\nMetoda wagowa PN-EN 12880:2004 Odpady O) kod: 19 08 05 Sucha pozostalosc (sucha masa) / zawartosc wody\nZakres (0,2 – 99,8) %\nMetoda wagowa PN-EN 12880:2004","categories":["environment","water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,2 – 99,8) %"}],"search_en":"Gravimetric method Laboratory Range PN-EN 12880:2004","technique_en":"Gravimetric method","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,2 – 99,8) %"}],"search_zh":"重量法 实验室 范围 PN-EN 12880:2004","technique_zh":"重量法"},{"_id":"6a83b167af14b9c0e7b207df","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Strata przy prażeniu (substancje organiczne)","parameters":[{"name":"Zakres","range":"(1,00 – 99,0) %"},{"name":"Pozostałość po prażeniu (substancje mineralne)"},{"name":"Zakres","range":"(1,00 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata przy prażeniu (substancje organiczne)\nZakres:\nZakres (1,00 – 99,0) %\nPozostałość po prażeniu (substancje mineralne)\nZakres (1,00 – 99,0) %\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. z 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Strata przy prażeniu (substancje organiczne)\nZakres:\nZakres (1,00 – 99,0) %\nPozostałość po prażeniu (substancje mineralne)\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 12879:2004 Odpady O) kod: 19 08 05 Strata przy prazeniu (substancje organiczne)\nZakres:\nZakres (1,00 – 99,0) %\nPozostalosc po prazeniu (substancje mineralne)\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 12879:2004","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Loss on ignition (organic matter)","parameters_en":[{"name":"Range","range":"(1,00 – 99,0) %"},{"name":"Residue on ignition (mineral substances)"},{"name":"Range","range":"(1,00 – 99,0) %"}],"search_en":"Loss on ignition (organic matter) Gravimetric method Laboratory Range Residue on ignition (mineral substances) Range PN-EN 12879:2004","technique_en":"Gravimetric method","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,00 – 99,0) %"},{"name":"Pozostałość po prażeniu (substancje mineralne)"},{"name":"范围","range":"(1,00 – 99,0) %"}],"search_zh":"烧失量（有机物质） 重量法 实验室 范围 范围 PN-EN 12879:2004","technique_zh":"重量法","methodology_zh":"烧失量（有机物质）"},{"_id":"6a83b167af14b9c0e7b207e0","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(1000 – 100 000) mg/kg"},{"name":"Zakres","range":"(0,10 – 10) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda spektrofotometryczna","reference":"PA-13/3 wydanie z dnia 30.12.2022 r.","norm_bases":["PA-13/3 wydanie z dnia 30.12.2022 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. z 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość fosforu ogólnego\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda spektrofotometryczna PA-13/3 wydanie z dnia 30.12.2022 r. Odpady O) kod: 19 08 05 Zawartosc fosforu ogolnego\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda spektrofotometryczna PA-13/3 wydanie z dnia 30.12.2022 r.","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(1000 – 100 000) mg/kg"},{"name":"Range","range":"(0,10 – 10) %"}],"search_en":"Total phosphorus content Spectrophotometric method Laboratory Range Range PA-13/3 wydanie z dnia 30.12.2022 r.","technique_en":"Spectrophotometric method","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1000 – 100 000) mg/kg"},{"name":"范围","range":"(0,10 – 10) %"}],"search_zh":"总磷含量 分光光度法 实验室 范围 范围 PA-13/3 wydanie z dnia 30.12.2022 r.","technique_zh":"分光光度法","methodology_zh":"总磷含量"},{"_id":"6a83b167af14b9c0e7b207e1","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1000 – 100 000) mg/kg"},{"name":"Zakres","range":"(0,10 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. z 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość azotu Kjeldahla\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 13342:2002 Odpady O) kod: 19 08 05 Zawartosc azotu Kjeldahla\nZakres:\nZakres (1000 – 100 000) mg/kg\nZakres (0,10 – 10) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(1000 – 100 000) mg/kg"},{"name":"Range","range":"(0,10 – 10) %"}],"search_en":"Kjeldahl nitrogen content Titrimetric method Laboratory Range Range PN-EN 13342:2002","technique_en":"Titrimetric method","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1000 – 100 000) mg/kg"},{"name":"范围","range":"(0,10 – 10) %"}],"search_zh":"凯氏氮含量 滴定法 实验室 范围 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a83b167af14b9c0e7b207e2","lab_id":"69ad52a3de79e566650fb41a","country":"PL","accr_number":"AB 817","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość pierwiastków","parameters":[{"name":"chrom","range":"(1,00 – 1000) mg/kg"},{"name":"cynk","range":"(1,00 – 7000) mg/kg"},{"name":"fosfor","range":"(2,00 – 100000) mg/kg"},{"name":"kadm","range":"(0,50 – 150) mg/kg"},{"name":"magnez","range":"(20 – 100000) mg/kg"},{"name":"miedź","range":"(1,00 – 800) mg/kg"},{"name":"nikiel","range":"(1,00 – 1000) mg/kg"},{"name":"ołów","range":"(1,00 – 500) mg/kg"},{"name":"rtęć","range":"(1,00 – 30) mg/kg"},{"name":"wapń","range":"(20 – 200000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nchrom (1,00 – 1000) mg/kg\ncynk (1,00 – 7000) mg/kg\nfosfor (2,00 – 100000) mg/kg\nkadm (0,50 – 150) mg/kg\nmagnez (20 – 100000) mg/kg\nmiedź (1,00 – 800) mg/kg\nnikiel (1,00 – 1000) mg/kg\nołów (1,00 – 500) mg/kg\nrtęć (1,00 – 30) mg/kg\nwapń (20 – 200000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 22036:2024-07","norm_bases":["PN-EN ISO 22036:2024-07"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. z 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość pierwiastków\nZakres:\nchrom (1,00 – 1000) mg/kg\ncynk (1,00 – 7000) mg/kg\nfosfor (2,00 – 100000) mg/kg\nkadm (0,50 – 150) mg/kg\nmagnez (20 – 100000) mg/kg\nmiedź (1,00 – 800) mg/kg\nnikiel (1,00 – 1000) mg/kg\nołów (1,00 – 500) mg/kg\nrtęć (1,00 – 30) mg/kg\nwapń (20 – 200000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 22036:2024-07 Odpady O) kod: 19 08 05 Zawartosc pierwiastkow\nZakres:\nchrom (1,00 – 1000) mg/kg\ncynk (1,00 – 7000) mg/kg\nfosfor (2,00 – 100000) mg/kg\nkadm (0,50 – 150) mg/kg\nmagnez (20 – 100000) mg/kg\nmiedz (1,00 – 800) mg/kg\nnikiel (1,00 – 1000) mg/kg\nolow (1,00 – 500) mg/kg\nrtec (1,00 – 30) mg/kg\nwapn (20 – 200000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 22036:2024-07","categories":["environment","materials"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Element content","parameters_en":[{"name":"chromium","range":"(1,00 – 1000) mg/kg"},{"name":"zinc","range":"(1,00 – 7000) mg/kg"},{"name":"phosphorus","range":"(2,00 – 100000) mg/kg"},{"name":"cadmium","range":"(0,50 – 150) mg/kg"},{"name":"magnesium","range":"(20 – 100000) mg/kg"},{"name":"copper","range":"(1,00 – 800) mg/kg"},{"name":"nickel","range":"(1,00 – 1000) mg/kg"},{"name":"lead","range":"(1,00 – 500) mg/kg"},{"name":"mercury","range":"(1,00 – 30) mg/kg"},{"name":"calcium","range":"(20 – 200000) mg/kg"}],"search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Laboratory chromium zinc phosphorus cadmium magnesium copper nickel lead mercury calcium PN-EN ISO 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","lab_section_zh":"实验室","methodology_zh":"元素含量","parameters_zh":[{"name":"铬","range":"(1,00 – 1000) mg/kg"},{"name":"锌","range":"(1,00 – 7000) mg/kg"},{"name":"磷","range":"(2,00 – 100000) mg/kg"},{"name":"镉","range":"(0,50 – 150) mg/kg"},{"name":"镁","range":"(20 – 100000) mg/kg"},{"name":"铜","range":"(1,00 – 800) mg/kg"},{"name":"镍","range":"(1,00 – 1000) mg/kg"},{"name":"铅","range":"(1,00 – 500) mg/kg"},{"name":"汞","range":"(1,00 – 30) mg/kg"},{"name":"钙","range":"(20 – 200000) mg/kg"}],"search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 实验室 铬 锌 磷 镉 镁 铜 镍 铅 汞 钙 PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"}],"has_pdf":true}