{"lab":{"_id":"69ad52a3de79e566650fb40a","accr_number":"AB 802","country":"PL","accr_body":"PCA","address":"„HIGIENA PRACY” MAREK SMOCZYŃSKI, ul. Jasna 3B/7,59-400 Jawor, ul. Starojaworska 29B/3, 59-400 Jawor (Działalność techniczna)","categories":["environment","materials"],"city":"Jawor","imported_at":"2026-03-08T10:42:43.265Z","methods_count":139,"name":"PRACOWNIA BADAŃ ŚRODOWISKA PRACY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_802.pdf"],"scope_summary":"","search_text":"pracownia badań środowiska pracy „higiena pracy” marek smoczyński, ul. jasna 3b/7,59-400 jawor, ul. starojaworska 29b/3, 59-400 jawor (działalność techniczna) environment materials other petro food metrology","status":"active","updated_at":"2026-03-08T14:51:41.392Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:05:04.406Z","location":{"type":"Point","coordinates":[19.2717,50.2056]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20802,podmiot.html","fields_of_testing":[{"codes":"A/13","pl":"Badania akustyczne i drgań – maszyny i urządzenia – hałas","en":""},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, mikroklimat, promieniowanie optyczne)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors – noise, lighting, vibration, microclimate, non-laser optical radiation)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne – hałas","en":"Tests concerning environmental engineering (environmental and climatic) – general environment – noise"},{"codes":"N/33/P","pl":"Badanie właściwości fizycznych i pobieranie próbek– środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling) – working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek powietrza","en":"Sampling of air"}],"issue":{"no":"24","date":"04.05.2026"},"parse_date":"2026-08-18T01:05:04.406Z","parse_source":"agent-claude-code","map_coord":[51.061144,16.182076],"map_geo":"nominatim-street","lab_locations":[{"name":"PRACOWNIA BADAŃ ŚRODOWISKA PRACY","address":"ul. Jasna 3B/7,59-400 Jawor","city":"Jawor","postal":"59-400"},{"name":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","address":"ul. Starojaworska 29 B/3, 59-400 Jawor (Działalność techniczna)","city":"Jawor","postal":"59-400"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/527ea27098495d42009b15cf3f96b4bb/AB%20802.pdf","has_en":true,"category_counts":{"environment":139,"materials":5,"construction":2,"petro":1,"automotive":1},"category_scores":{"environment":130.55,"materials":0.17,"construction":0.03,"petro":0.01,"automotive":0.01},"has_zh":true},"methods":[{"_id":"6a83afc0af14b9c0e7b205c5","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"azbest – włókna respirabilne"},{"name":"sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"},{"name":"węglik krzemu włóknisty – włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – włókna respirabilne\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest – wlokna respirabilne\nsztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nweglik krzemu wloknisty – wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"asbestos – respirable fibres"},{"name":"man-made mineral fibres excluding refractory ceramic fibres – respirable fibres"},{"name":"silicon carbide fibrous – respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos – respirable fibres man-made mineral fibres excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres PN-Z-04008-7:2002 + Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 石棉 — 呼吸性纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 纤维状碳化硅 － 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002 + Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"石棉 — 呼吸性纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"},{"name":"纤维状碳化硅 － 呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}]},{"_id":"6a83afc0af14b9c0e7b205c6","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna"}],"technique":"Metoda stacjonarna; Metoda dozymetrii indywidualnej","techniques":["Metoda stacjonarna","Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nMetoda stacjonarna; Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja respirabilna – frakcja torakalna\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Stationary method; Personal dosimetry method inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction PN-Z-04008-7:2002 + Az1:2004","technique_en":"Stationary method; Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点法；个体剂量测定法 无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘 PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"无机物质，其中包括 － 可吸入性粉尘 － 呼吸性粉尘 － 胸腔性粉尘"}],"technique_zh":"定点法；个体剂量测定法"},{"_id":"6a83afc0af14b9c0e7b205c7","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 + Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002 + Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83afc0af14b9c0e7b205c8","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie / zawartość krzemionki krystalicznej – kwarc, krystobalit – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,0098–3,0) mg/m3"},{"name":"Zakres","range":"(0,00773 – 0,5) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)"],"computed":[],"activity":"Stężenie / zawartość krzemionki krystalicznej – kwarc, krystobalit – frakcja respirabilna\nZakres:\nZakres (0,0098–3,0) mg/m3\nZakres (0,00773 – 0,5) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74), s.117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74), s.117-130"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie / zawartość krzemionki krystalicznej – kwarc, krystobalit – frakcja respirabilna\nZakres:\nZakres (0,0098–3,0) mg/m3\nZakres (0,00773 – 0,5) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni z transformacją Fouriera (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74), s.117-130 Srodowisko pracy – powietrze Stezenie / zawartosc krzemionki krystalicznej – kwarc, krystobalit – frakcja respirabilna\nZakres:\nZakres (0,0098–3,0) mg/m3\nZakres (0,00773 – 0,5) mg w probce\nMetoda spektrometrii w zakresie podczerwieni z transformacja Fouriera (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74), s.117-130","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of crystalline silica – quartz, cristobalite – respirable fraction","parameters_en":[{"name":"Range","range":"(0,0098–3,0) mg/m3"},{"name":"Range","range":"(0,00773 – 0,5) mg w próbce"}],"search_en":"Workplace environment – air Concentration / content of crystalline silica – quartz, cristobalite – respirable fraction Fourier transform infrared spectrometry (FT-IR) Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74), s.117-130","technique_en":"Fourier transform infrared spectrometry (FT-IR)","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,0098–3,0) mg/m3"},{"name":"范围","range":"(0,00773 – 0,5) mg w próbce"}],"search_zh":"工作场所环境 — 空气 傅里叶变换红外光谱法（FT-IR） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74), s.117-130","test_object_zh":"工作场所环境 — 空气","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a83afc0af14b9c0e7b205c9","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"asfalt naftowy"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"kaolin"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"węglik krzemu, włóknisty"},{"name":"sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"Zakres","range":"(0,040 -17,36) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nwęglik krzemu, włóknisty\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nZakres (0,040 -17,36) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05","norm_bases":["PN-Z-04507:2022-05"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nwęglik krzemu, włóknisty\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nZakres (0,040 -17,36) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nweglik krzemu, wloknisty\nsztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych\nZakres (0,040 -17,36) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"petroleum bitumen"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"natural graphite"},{"name":"synthetic graphite"},{"name":"kaolin"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"carbon black"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"silicon carbide, non-fibrous"},{"name":"silicon carbide, fibrous"},{"name":"man-made mineral fibres excluding refractory ceramic fibres"},{"name":"Range","range":"(0,040 -17,36) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents – inhalable fraction Gravimetric method apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous silicon carbide, fibrous man-made mineral fibres excluding refractory ceramic fibres Range PN-Z-04507:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"石油沥青"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"碳化硅，纤维状"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"范围","range":"(0,040 -17,36) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 石油沥青 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 碳化硅，纤维状 人造矿物纤维，耐火陶瓷纤维除外 范围 PN-Z-04507:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a83afc0af14b9c0e7b205ca","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"spaliny silnika Diesla"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,031 - 20) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nspaliny silnika Diesla\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,031 - 20) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05","norm_bases":["PN-Z-04508:2022-05"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nspaliny silnika Diesla\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,031 - 20) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nspaliny silnika Diesla\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,031 - 20) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05","categories":["environment","construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"diesel engine exhaust"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,031 - 20) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents – respirable fraction Gravimetric method apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts diesel engine exhaust talc coal (hard, brown) Range PN-Z-04508:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"柴油机排气"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,031 - 20) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 柴油机排气 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a83afc0af14b9c0e7b205cb","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza III tlenek żelaza II tetratlenek triżelaza – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,035 – 28,6) mg/m3"},{"name":"Zakres","range":"(0,025 – 20,6) mg w próbce"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,032 – 26,0) mg/m3"},{"name":"Zakres","range":"(0,025 – 20,6) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza III tlenek żelaza II tetratlenek triżelaza – frakcja wdychalna\nZakres:\nZakres (0,035 – 28,6) mg/m3\nZakres (0,025 – 20,6) mg w próbce\n– frakcja respirabilna\nZakres (0,032 – 26,0) mg/m3\nZakres (0,025 – 20,6) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza III tlenek żelaza II tetratlenek triżelaza – frakcja wdychalna\nZakres:\nZakres (0,035 – 28,6) mg/m3\nZakres (0,025 – 20,6) mg w próbce\n– frakcja respirabilna\nZakres (0,032 – 26,0) mg/m3\nZakres (0,025 – 20,6) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc tlenkow zelaza w przeliczeniu na Fe tlenek zelaza III tlenek zelaza II tetratlenek trizelaza – frakcja wdychalna\nZakres:\nZakres (0,035 – 28,6) mg/m3\nZakres (0,025 – 20,6) mg w probce\n– frakcja respirabilna\nZakres (0,032 – 26,0) mg/m3\nZakres (0,025 – 20,6) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,035 – 28,6) mg/m3"},{"name":"Range","range":"(0,025 – 20,6) mg w próbce"},{"name":"– respirable fraction"},{"name":"Range","range":"(0,032 – 26,0) mg/m3"},{"name":"Range","range":"(0,025 – 20,6) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide – inhalable fraction Microwave plasma atomic emission spectrometry (MP-AES) Range Range – respirable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,035 – 28,6) mg/m3"},{"name":"范围","range":"(0,025 – 20,6) mg w próbce"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,032 – 26,0) mg/m3"},{"name":"范围","range":"(0,025 – 20,6) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 — 呼吸性组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205cc","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0021– 1,04) mg/m3"},{"name":"Zakres","range":"(0,0015 – 0,75) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0019 – 0,95) mg/m3"},{"name":"Zakres","range":"(0,0015 – 0,75) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0021– 1,04) mg/m3\nZakres (0,0015 – 0,75) mg w próbce\nfrakcja respirabilna\nZakres (0,0019 – 0,95) mg/m3\nZakres (0,0015 – 0,75) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0021– 1,04) mg/m3\nZakres (0,0015 – 0,75) mg w próbce\nfrakcja respirabilna\nZakres (0,0019 – 0,95) mg/m3\nZakres (0,0015 – 0,75) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,0021– 1,04) mg/m3\nZakres (0,0015 – 0,75) mg w probce\nfrakcja respirabilna\nZakres (0,0019 – 0,95) mg/m3\nZakres (0,0015 – 0,75) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of manganese and its inorganic compounds calculated as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0021– 1,04) mg/m3"},{"name":"Range","range":"(0,0015 – 0,75) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,0019 – 0,95) mg/m3"},{"name":"Range","range":"(0,0015 – 0,75) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of manganese and its inorganic compounds calculated as Mn Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range respirable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0021– 1,04) mg/m3"},{"name":"范围","range":"(0,0015 – 0,75) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0019 – 0,95) mg/m3"},{"name":"范围","range":"(0,0015 – 0,75) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205cd","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,0069 – 4,00) mg/m3"},{"name":"Zakres","range":"(0,0050 – 2,88) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres:\nZakres (0,0069 – 4,00) mg/m3\nZakres (0,0050 – 2,88) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość miedzi i jej związków nieorganicznych w przeliczeniu na Cu\nZakres:\nZakres (0,0069 – 4,00) mg/m3\nZakres (0,0050 – 2,88) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc miedzi i jej zwiazkow nieorganicznych w przeliczeniu na Cu\nZakres:\nZakres (0,0069 – 4,00) mg/m3\nZakres (0,0050 – 2,88) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of copper and its inorganic compounds expressed as Cu","parameters_en":[{"name":"Range","range":"(0,0069 – 4,00) mg/m3"},{"name":"Range","range":"(0,0050 – 2,88) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of copper and its inorganic compounds expressed as Cu Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0069 – 4,00) mg/m3"},{"name":"范围","range":"(0,0050 – 2,88) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205ce","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość ołowiu i jego związków nieorganicznych - w przeliczeniu na Pb","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,00174 – 2,78) mg/m3"},{"name":"Zakres","range":"(0,0013 – 2,00) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość ołowiu i jego związków nieorganicznych - w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,00174 – 2,78) mg/m3\nZakres (0,0013 – 2,00) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość ołowiu i jego związków nieorganicznych - w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,00174 – 2,78) mg/m3\nZakres (0,0013 – 2,00) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc olowiu i jego zwiazkow nieorganicznych - w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,00174 – 2,78) mg/m3\nZakres (0,0013 – 2,00) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of lead and its inorganic compounds - calculated as Pb","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,00174 – 2,78) mg/m3"},{"name":"Range","range":"(0,0013 – 2,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of lead and its inorganic compounds - calculated as Pb Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,00174 – 2,78) mg/m3"},{"name":"范围","range":"(0,0013 – 2,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205cf","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,0060 – 6,04) mg/m3"},{"name":"Zakres","range":"(0,0043 – 4,35) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość wodorotlenku sodu\nZakres:\nZakres (0,0060 – 6,04) mg/m3\nZakres (0,0043 – 4,35) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość wodorotlenku sodu\nZakres:\nZakres (0,0060 – 6,04) mg/m3\nZakres (0,0043 – 4,35) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc wodorotlenku sodu\nZakres:\nZakres (0,0060 – 6,04) mg/m3\nZakres (0,0043 – 4,35) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sodium hydroxide","parameters_en":[{"name":"Range","range":"(0,0060 – 6,04) mg/m3"},{"name":"Range","range":"(0,0043 – 4,35) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of sodium hydroxide Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0060 – 6,04) mg/m3"},{"name":"范围","range":"(0,0043 – 4,35) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d0","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,0050 – 4,99) mg/m3"},{"name":"Zakres","range":"(0,0036 – 3,59) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość wodorotlenku potasu\nZakres:\nZakres (0,0050 – 4,99) mg/m3\nZakres (0,0036 – 3,59) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość wodorotlenku potasu\nZakres:\nZakres (0,0050 – 4,99) mg/m3\nZakres (0,0036 – 3,59) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc wodorotlenku potasu\nZakres:\nZakres (0,0050 – 4,99) mg/m3\nZakres (0,0036 – 3,59) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of potassium hydroxide","parameters_en":[{"name":"Range","range":"(0,0050 – 4,99) mg/m3"},{"name":"Range","range":"(0,0036 – 3,59) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of potassium hydroxide Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0050 – 4,99) mg/m3"},{"name":"范围","range":"(0,0036 – 3,59) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d1","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr","parameters":[{"name":"Zakres","range":"(0,0174 – 1,75) mg/m3"},{"name":"Zakres","range":"(0,0125 – 1,26) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,0174 – 1,75) mg/m3\nZakres (0,0125 – 1,26) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość chromu metalicznego, związków chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,0174 – 1,75) mg/m3\nZakres (0,0125 – 1,26) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc chromu metalicznego, zwiazkow chromu: chrom (II), chrom (III), chrom (VI) – w przeliczeniu na Cr\nZakres:\nZakres (0,0174 – 1,75) mg/m3\nZakres (0,0125 – 1,26) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["materials","environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) – calculated as Cr","parameters_en":[{"name":"Range","range":"(0,0174 – 1,75) mg/m3"},{"name":"Range","range":"(0,0125 – 1,26) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of metallic chromium, chromium compounds: chromium (II), chromium (III), chromium (VI) – calculated as Cr Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0174 – 1,75) mg/m3"},{"name":"范围","range":"(0,0125 – 1,26) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d2","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Zawartość chromu metalicznego, związków chromu (II) – w przeliczeniu na, Cr (II), związków chromu (III) – w przeliczeniu na Cr (III)","parameters":[],"technique":"Metoda z obliczeń","techniques":["Metoda z obliczeń"],"computed":[],"activity":"Zawartość chromu metalicznego, związków chromu (II) – w przeliczeniu na, Cr (II), związków chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczeń","reference":"PB-06/32 wydanie 1 z dnia 20.11.2023 r.","norm_bases":["PB-06/32 wydanie 1 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Zawartość chromu metalicznego, związków chromu (II) – w przeliczeniu na, Cr (II), związków chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczeń PB-06/32 wydanie 1 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Zawartosc chromu metalicznego, zwiazkow chromu (II) – w przeliczeniu na, Cr (II), zwiazkow chromu (III) – w przeliczeniu na Cr (III)\nMetoda z obliczen PB-06/32 wydanie 1 z dnia 20.11.2023 r.","categories":["materials","environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metallic chromium, chromium (II) compounds – calculated as, Cr (II), chromium (III) compounds – calculated as Cr (III)","search_en":"Workplace environment – air – air samples Content of metallic chromium, chromium (II) compounds – calculated as, Cr (II), chromium (III) compounds – calculated as Cr (III) Calculation method PB-06/32 wydanie 1 z dnia 20.11.2023 r.","technique_en":"Calculation method","test_object_en":"Workplace environment – air – air samples","search_zh":"工作场所环境 — 空气 — 空气样品 计算法 PB-06/32 wydanie 1 z dnia 20.11.2023 r.","technique_zh":"计算法","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205d3","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,0014 – 1,74) mg/m3"},{"name":"Zakres","range":"(0,00075 - 1,25) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość niklu metalicznego\nZakres:\nZakres (0,0014 – 1,74) mg/m3\nZakres (0,00075 - 1,25) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość niklu metalicznego\nZakres:\nZakres (0,0014 – 1,74) mg/m3\nZakres (0,00075 - 1,25) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc niklu metalicznego\nZakres:\nZakres (0,0014 – 1,74) mg/m3\nZakres (0,00075 - 1,25) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["materials","environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of metallic nickel","parameters_en":[{"name":"Range","range":"(0,0014 – 1,74) mg/m3"},{"name":"Range","range":"(0,00075 - 1,25) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of metallic nickel Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0014 – 1,74) mg/m3"},{"name":"范围","range":"(0,00075 - 1,25) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d4","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość związków niklu w przeliczeniu na Ni","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0014 – 1,74) mg/m3"},{"name":"Zakres","range":"(0,00075 - 1,25) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,00095 – 1,58) mg/m3"},{"name":"Zakres","range":"(0,00075 - 1,25) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość związków niklu w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 1,74) mg/m3\nZakres (0,00075 - 1,25) mg w próbce\nfrakcja respirabilna\nZakres (0,00095 – 1,58) mg/m3\nZakres (0,00075 - 1,25) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość związków niklu w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 1,74) mg/m3\nZakres (0,00075 - 1,25) mg w próbce\nfrakcja respirabilna\nZakres (0,00095 – 1,58) mg/m3\nZakres (0,00075 - 1,25) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc zwiazkow niklu w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0014 – 1,74) mg/m3\nZakres (0,00075 - 1,25) mg w probce\nfrakcja respirabilna\nZakres (0,00095 – 1,58) mg/m3\nZakres (0,00075 - 1,25) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of nickel compounds calculated as Ni","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0014 – 1,74) mg/m3"},{"name":"Range","range":"(0,00075 - 1,25) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,00095 – 1,58) mg/m3"},{"name":"Range","range":"(0,00075 - 1,25) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of nickel compounds calculated as Ni Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range respirable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0014 – 1,74) mg/m3"},{"name":"范围","range":"(0,00075 - 1,25) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,00095 – 1,58) mg/m3"},{"name":"范围","range":"(0,00075 - 1,25) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d5","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie /zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,00035 – 0,087) mg/m3"},{"name":"Zakres","range":"(0,00025 – 0,063) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie /zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,00035 – 0,087) mg/m3\nZakres (0,00025 – 0,063) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie /zawartość arsenu i jego związków nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,00035 – 0,087) mg/m3\nZakres (0,00025 – 0,063) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie /zawartosc arsenu i jego zwiazkow nieorganicznych w przeliczeniu na As\nZakres:\nfrakcja wdychalna\nZakres (0,00035 – 0,087) mg/m3\nZakres (0,00025 – 0,063) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of arsenic and its inorganic compounds expressed as As","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,00035 – 0,087) mg/m3"},{"name":"Range","range":"(0,00025 – 0,063) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of arsenic and its inorganic compounds expressed as As Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,00035 – 0,087) mg/m3"},{"name":"范围","range":"(0,00025 – 0,063) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d6","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość dichlorku cynku – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,058 – 6,94) mg/m3"},{"name":"Zakres","range":"(0,042 – 5,00) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość dichlorku cynku – frakcja wdychalna\nZakres:\nZakres (0,058 – 6,94) mg/m3\nZakres (0,042 – 5,00) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość dichlorku cynku – frakcja wdychalna\nZakres:\nZakres (0,058 – 6,94) mg/m3\nZakres (0,042 – 5,00) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc dichlorku cynku – frakcja wdychalna\nZakres:\nZakres (0,058 – 6,94) mg/m3\nZakres (0,042 – 5,00) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of zinc dichloride – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,058 – 6,94) mg/m3"},{"name":"Range","range":"(0,042 – 5,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of zinc dichloride – inhalable fraction Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,058 – 6,94) mg/m3"},{"name":"范围","range":"(0,042 – 5,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d7","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość tlenku cynku w przeliczeniu na Zn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,0069 – 14,5) mg/m3"},{"name":"Zakres","range":"(0,0050 – 10,4) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres:\nZakres (0,0069 – 14,5) mg/m3\nZakres (0,0050 – 10,4) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres:\nZakres (0,0069 – 14,5) mg/m3\nZakres (0,0050 – 10,4) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc tlenku cynku w przeliczeniu na Zn – frakcja wdychalna\nZakres:\nZakres (0,0069 – 14,5) mg/m3\nZakres (0,0050 – 10,4) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of zinc oxide calculated as Zn – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,0069 – 14,5) mg/m3"},{"name":"Range","range":"(0,0050 – 10,4) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of zinc oxide calculated as Zn – inhalable fraction Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0069 – 14,5) mg/m3"},{"name":"范围","range":"(0,0050 – 10,4) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d8","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość srebra – frakcja wdychalna Stężenie / zawartość srebra","parameters":[{"name":"związki nierozpuszczalne"},{"name":"Zakres","range":"(0,0024 – 3,47) mg/m3"},{"name":"Zakres","range":"(0,0018 – 2,50) mg w próbce-"},{"name":"związki rozpuszczalne"},{"name":"Zakres","range":"(0,00097 – 3,47) mg/m3"},{"name":"Zakres","range":"(0,00070 – 2,50) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość srebra – frakcja wdychalna Stężenie / zawartość srebra\nZakres:\nzwiązki nierozpuszczalne\nZakres (0,0024 – 3,47) mg/m3\nZakres (0,0018 – 2,50) mg w próbce-\nzwiązki rozpuszczalne\nZakres (0,00097 – 3,47) mg/m3\nZakres (0,00070 – 2,50) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość srebra – frakcja wdychalna Stężenie / zawartość srebra\nZakres:\nzwiązki nierozpuszczalne\nZakres (0,0024 – 3,47) mg/m3\nZakres (0,0018 – 2,50) mg w próbce-\nzwiązki rozpuszczalne\nZakres (0,00097 – 3,47) mg/m3\nZakres (0,00070 – 2,50) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc srebra – frakcja wdychalna Stezenie / zawartosc srebra\nZakres:\nzwiazki nierozpuszczalne\nZakres (0,0024 – 3,47) mg/m3\nZakres (0,0018 – 2,50) mg w probce-\nzwiazki rozpuszczalne\nZakres (0,00097 – 3,47) mg/m3\nZakres (0,00070 – 2,50) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of silver – inhalable fraction Concentration / content of silver","parameters_en":[{"name":"insoluble compounds"},{"name":"Range","range":"(0,0024 – 3,47) mg/m3"},{"name":"Range","range":"(0,0018 – 2,50) mg w próbce-"},{"name":"soluble compounds"},{"name":"Range","range":"(0,00097 – 3,47) mg/m3"},{"name":"Range","range":"(0,00070 – 2,50) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of silver – inhalable fraction Concentration / content of silver Microwave plasma atomic emission spectrometry (MP-AES) insoluble compounds Range Range soluble compounds Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"związki nierozpuszczalne"},{"name":"范围","range":"(0,0024 – 3,47) mg/m3"},{"name":"范围","range":"(0,0018 – 2,50) mg w próbce-"},{"name":"związki rozpuszczalne"},{"name":"范围","range":"(0,00097 – 3,47) mg/m3"},{"name":"范围","range":"(0,00070 – 2,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205d9","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie kadmu i jego związków nieorganicznych w przeliczeniu na Cd","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,000097– 0,28) mg/m3"},{"name":"Zakres","range":"(0,00007– 0,20) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie kadmu i jego związków nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,000097– 0,28) mg/m3\nZakres (0,00007– 0,20) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie kadmu i jego związków nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,000097– 0,28) mg/m3\nZakres (0,00007– 0,20) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie kadmu i jego zwiazkow nieorganicznych w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nZakres (0,000097– 0,28) mg/m3\nZakres (0,00007– 0,20) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of cadmium and its inorganic compounds calculated as Cd","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,000097– 0,28) mg/m3"},{"name":"Range","range":"(0,00007– 0,20) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration of cadmium and its inorganic compounds calculated as Cd Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,000097– 0,28) mg/m3"},{"name":"范围","range":"(0,00007– 0,20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205da","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu, w przeliczeniu na Sn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,17– 4,00) mg/m3"},{"name":"Zakres","range":"(0,12 – 2,88) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu, w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,17– 4,00) mg/m3\nZakres (0,12 – 2,88) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu, w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,17– 4,00) mg/m3\nZakres (0,12 – 2,88) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc cyny i jej zwiazkow nieorganicznych, z wyjatkiem stannanu, w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,17– 4,00) mg/m3\nZakres (0,12 – 2,88) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of tin and its inorganic compounds, except stannane, expressed as Sn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,17– 4,00) mg/m3"},{"name":"Range","range":"(0,12 – 2,88) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of tin and its inorganic compounds, except stannane, expressed as Sn Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,17– 4,00) mg/m3"},{"name":"范围","range":"(0,12 – 2,88) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205db","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość glinu metalicznego, glinu w proszku Stężenie wodorotlenku glinu, tritlenku glinu, w przeliczeniu na Al","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,069 – 5,00) mg/m3"},{"name":"Zakres","range":"(0,050 – 3,60) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,063 – 4,54) mg/m3"},{"name":"Zakres","range":"(0,050 – 3,60) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie / zawartość glinu metalicznego, glinu w proszku Stężenie wodorotlenku glinu, tritlenku glinu, w przeliczeniu na Al\nZakres:\nfrakcja wdychalna\nZakres (0,069 – 5,00) mg/m3\nZakres (0,050 – 3,60) mg w próbce\nfrakcja respirabilna\nZakres (0,063 – 4,54) mg/m3\nZakres (0,050 – 3,60) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość glinu metalicznego, glinu w proszku Stężenie wodorotlenku glinu, tritlenku glinu, w przeliczeniu na Al\nZakres:\nfrakcja wdychalna\nZakres (0,069 – 5,00) mg/m3\nZakres (0,050 – 3,60) mg w próbce\nfrakcja respirabilna\nZakres (0,063 – 4,54) mg/m3\nZakres (0,050 – 3,60) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc glinu metalicznego, glinu w proszku Stezenie wodorotlenku glinu, tritlenku glinu, w przeliczeniu na Al\nZakres:\nfrakcja wdychalna\nZakres (0,069 – 5,00) mg/m3\nZakres (0,050 – 3,60) mg w probce\nfrakcja respirabilna\nZakres (0,063 – 4,54) mg/m3\nZakres (0,050 – 3,60) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["materials","environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of metallic aluminium, aluminium powder Concentration of aluminium hydroxide, aluminium trioxide, expressed as Al","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,069 – 5,00) mg/m3"},{"name":"Range","range":"(0,050 – 3,60) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,063 – 4,54) mg/m3"},{"name":"Range","range":"(0,050 – 3,60) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of metallic aluminium, aluminium powder Concentration of aluminium hydroxide, aluminium trioxide, expressed as Al Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range respirable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,069 – 5,00) mg/m3"},{"name":"范围","range":"(0,050 – 3,60) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,063 – 4,54) mg/m3"},{"name":"范围","range":"(0,050 – 3,60) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205dc","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość kobaltu i jego związki nieorganiczne w przeliczeniu na Co","parameters":[{"name":"Zakres","range":"(0,0017– 1,04) mg/m3"},{"name":"Zakres","range":"(0,0013 – 0,75) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość kobaltu i jego związki nieorganiczne w przeliczeniu na Co\nZakres:\nZakres (0,0017– 1,04) mg/m3\nZakres (0,0013 – 0,75) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość kobaltu i jego związki nieorganiczne w przeliczeniu na Co\nZakres:\nZakres (0,0017– 1,04) mg/m3\nZakres (0,0013 – 0,75) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc kobaltu i jego zwiazki nieorganiczne w przeliczeniu na Co\nZakres:\nZakres (0,0017– 1,04) mg/m3\nZakres (0,0013 – 0,75) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of cobalt and its inorganic compounds calculated as Co","parameters_en":[{"name":"Range","range":"(0,0017– 1,04) mg/m3"},{"name":"Range","range":"(0,0013 – 0,75) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of cobalt and its inorganic compounds calculated as Co Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0017– 1,04) mg/m3"},{"name":"范围","range":"(0,0013 – 0,75) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205dd","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość tlenku magnezu – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,0060 – 15,0) mg/m3"},{"name":"Zakres","range":"(0,0043 – 10,8) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość tlenku magnezu – frakcja wdychalna\nZakres:\nZakres (0,0060 – 15,0) mg/m3\nZakres (0,0043 – 10,8) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość tlenku magnezu – frakcja wdychalna\nZakres:\nZakres (0,0060 – 15,0) mg/m3\nZakres (0,0043 – 10,8) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc tlenku magnezu – frakcja wdychalna\nZakres:\nZakres (0,0060 – 15,0) mg/m3\nZakres (0,0043 – 10,8) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of magnesium oxide – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,0060 – 15,0) mg/m3"},{"name":"Range","range":"(0,0043 – 10,8) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of magnesium oxide – inhalable fraction Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0060 – 15,0) mg/m3"},{"name":"范围","range":"(0,0043 – 10,8) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205de","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość tlenku wapnia","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,024 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,018 – 18,0) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,022 – 22,7) mg/m3"},{"name":"Zakres","range":"(0,018 – 18,0) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość tlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,024 – 25,0) mg/m3\nZakres (0,018 – 18,0) mg w próbce\nfrakcja respirabilna\nZakres (0,022 – 22,7) mg/m3\nZakres (0,018 – 18,0) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość tlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,024 – 25,0) mg/m3\nZakres (0,018 – 18,0) mg w próbce\nfrakcja respirabilna\nZakres (0,022 – 22,7) mg/m3\nZakres (0,018 – 18,0) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc tlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,024 – 25,0) mg/m3\nZakres (0,018 – 18,0) mg w probce\nfrakcja respirabilna\nZakres (0,022 – 22,7) mg/m3\nZakres (0,018 – 18,0) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of calcium oxide","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,024 – 25,0) mg/m3"},{"name":"Range","range":"(0,018 – 18,0) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,022 – 22,7) mg/m3"},{"name":"Range","range":"(0,018 – 18,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of calcium oxide Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range respirable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,024 – 25,0) mg/m3"},{"name":"范围","range":"(0,018 – 18,0) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,022 – 22,7) mg/m3"},{"name":"范围","range":"(0,018 – 18,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205df","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość wodorotlenku wapnia","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,032 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,023 – 18,00) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,029 – 22,7) mg/m3"},{"name":"Zakres","range":"(0,023 – 18,0) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość wodorotlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,032 – 25,0) mg/m3\nZakres (0,023 – 18,00) mg w próbce\nfrakcja respirabilna\nZakres (0,029 – 22,7) mg/m3\nZakres (0,023 – 18,0) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość wodorotlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,032 – 25,0) mg/m3\nZakres (0,023 – 18,00) mg w próbce\nfrakcja respirabilna\nZakres (0,029 – 22,7) mg/m3\nZakres (0,023 – 18,0) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc wodorotlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,032 – 25,0) mg/m3\nZakres (0,023 – 18,00) mg w probce\nfrakcja respirabilna\nZakres (0,029 – 22,7) mg/m3\nZakres (0,023 – 18,0) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of calcium hydroxide","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,032 – 25,0) mg/m3"},{"name":"Range","range":"(0,023 – 18,00) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,029 – 22,7) mg/m3"},{"name":"Range","range":"(0,023 – 18,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of calcium hydroxide Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range respirable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,032 – 25,0) mg/m3"},{"name":"范围","range":"(0,023 – 18,00) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,029 – 22,7) mg/m3"},{"name":"范围","range":"(0,023 – 18,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e0","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość węglanu wapnia","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,043 – 25,0) mg/m3"},{"name":"Zakres","range":"(0,031 – 18,0) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość węglanu wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,043 – 25,0) mg/m3\nZakres (0,031 – 18,0) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość węglanu wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,043 – 25,0) mg/m3\nZakres (0,031 – 18,0) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc weglanu wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,043 – 25,0) mg/m3\nZakres (0,031 – 18,0) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of calcium carbonate","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,043 – 25,0) mg/m3"},{"name":"Range","range":"(0,031 – 18,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of calcium carbonate Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,043 – 25,0) mg/m3"},{"name":"范围","range":"(0,031 – 18,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e1","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość antymonu i jego związków nieorganicznych, z wyjątkiem stibanu - w przeliczeniu na Sb","parameters":[{"name":"Zakres","range":"(0,0001 – 3,00) mg/m3"},{"name":"Zakres","range":"(0,0001 – 2,16) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość antymonu i jego związków nieorganicznych, z wyjątkiem stibanu - w przeliczeniu na Sb\nZakres:\nZakres (0,0001 – 3,00) mg/m3\nZakres (0,0001 – 2,16) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość antymonu i jego związków nieorganicznych, z wyjątkiem stibanu - w przeliczeniu na Sb\nZakres:\nZakres (0,0001 – 3,00) mg/m3\nZakres (0,0001 – 2,16) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc antymonu i jego zwiazkow nieorganicznych, z wyjatkiem stibanu - w przeliczeniu na Sb\nZakres:\nZakres (0,0001 – 3,00) mg/m3\nZakres (0,0001 – 2,16) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of antimony and its inorganic compounds, except stibine - calculated as Sb","parameters_en":[{"name":"Range","range":"(0,0001 – 3,00) mg/m3"},{"name":"Range","range":"(0,0001 – 2,16) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of antimony and its inorganic compounds, except stibine - calculated as Sb Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0001 – 3,00) mg/m3"},{"name":"范围","range":"(0,0001 – 2,16) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e2","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość tytanu i jego związków - w przeliczeniu na Ti","parameters":[{"name":"Zakres","range":"(0,0347 – 26,0) mg/m3"},{"name":"Zakres","range":"(0,0250 – 18,7) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość tytanu i jego związków - w przeliczeniu na Ti\nZakres:\nZakres (0,0347 – 26,0) mg/m3\nZakres (0,0250 – 18,7) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość tytanu i jego związków - w przeliczeniu na Ti\nZakres:\nZakres (0,0347 – 26,0) mg/m3\nZakres (0,0250 – 18,7) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc tytanu i jego zwiazkow - w przeliczeniu na Ti\nZakres:\nZakres (0,0347 – 26,0) mg/m3\nZakres (0,0250 – 18,7) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of titanium and its compounds - calculated as Ti","parameters_en":[{"name":"Range","range":"(0,0347 – 26,0) mg/m3"},{"name":"Range","range":"(0,0250 – 18,7) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of titanium and its compounds - calculated as Ti Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0347 – 26,0) mg/m3"},{"name":"范围","range":"(0,0250 – 18,7) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e3","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość selenu i jego związków, z wyjątkiem selanu - w przeliczeniu na Se","parameters":[{"name":"Zakres","range":"(0,00030 – 1,04) mg/m3"},{"name":"Zakres","range":"(0,00030 – 0,75) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość selenu i jego związków, z wyjątkiem selanu - w przeliczeniu na Se\nZakres:\nZakres (0,00030 – 1,04) mg/m3\nZakres (0,00030 – 0,75) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość selenu i jego związków, z wyjątkiem selanu - w przeliczeniu na Se\nZakres:\nZakres (0,00030 – 1,04) mg/m3\nZakres (0,00030 – 0,75) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc selenu i jego zwiazkow, z wyjatkiem selanu - w przeliczeniu na Se\nZakres:\nZakres (0,00030 – 1,04) mg/m3\nZakres (0,00030 – 0,75) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of selenium and its compounds, except selane - calculated as Se","parameters_en":[{"name":"Range","range":"(0,00030 – 1,04) mg/m3"},{"name":"Range","range":"(0,00030 – 0,75) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of selenium and its compounds, except selane - calculated as Se Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,00030 – 1,04) mg/m3"},{"name":"范围","range":"(0,00030 – 0,75) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e4","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość rtęci pary i jej związki nieorganiczne - w przeliczeniu na Hg","parameters":[{"name":"Zakres","range":"(0,0017 – 1,03) mg/m3"},{"name":"Zakres","range":"(0,00060 – 0,37) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość rtęci pary i jej związki nieorganiczne - w przeliczeniu na Hg\nZakres:\nZakres (0,0017 – 1,03) mg/m3\nZakres (0,00060 – 0,37) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość rtęci pary i jej związki nieorganiczne - w przeliczeniu na Hg\nZakres:\nZakres (0,0017 – 1,03) mg/m3\nZakres (0,00060 – 0,37) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc rteci pary i jej zwiazki nieorganiczne - w przeliczeniu na Hg\nZakres:\nZakres (0,0017 – 1,03) mg/m3\nZakres (0,00060 – 0,37) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of mercury vapour and its inorganic compounds - calculated as Hg","parameters_en":[{"name":"Range","range":"(0,0017 – 1,03) mg/m3"},{"name":"Range","range":"(0,00060 – 0,37) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of mercury vapour and its inorganic compounds - calculated as Hg Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0017 – 1,03) mg/m3"},{"name":"范围","range":"(0,00060 – 0,37) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e5","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość baru i jego związków rozpuszczalnych - w przeliczeniu na Ba","parameters":[{"name":"Zakres","range":"(0,017 – 1,50) mg/m3"},{"name":"Zakres","range":"(0,013 – 1,08) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość baru i jego związków rozpuszczalnych - w przeliczeniu na Ba\nZakres:\nZakres (0,017 – 1,50) mg/m3\nZakres (0,013 – 1,08) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość baru i jego związków rozpuszczalnych - w przeliczeniu na Ba\nZakres:\nZakres (0,017 – 1,50) mg/m3\nZakres (0,013 – 1,08) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc baru i jego zwiazkow rozpuszczalnych - w przeliczeniu na Ba\nZakres:\nZakres (0,017 – 1,50) mg/m3\nZakres (0,013 – 1,08) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of barium and its soluble compounds - calculated as Ba","parameters_en":[{"name":"Range","range":"(0,017 – 1,50) mg/m3"},{"name":"Range","range":"(0,013 – 1,08) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of barium and its soluble compounds - calculated as Ba Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,017 – 1,50) mg/m3"},{"name":"范围","range":"(0,013 – 1,08) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e6","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość wolframu","parameters":[{"name":"frakcja wdychalna Stężenie/ zawartość wolframu i jego związków nierozpuszczalnych - w przeliczeniu na W Stężenie/ zawartość wolframu i jego związków rozpuszczalnych - w przeliczeniu na W"},{"name":"Zakres","range":"(0,035 – 15,0) mg/m3"},{"name":"Zakres","range":"(0,025 – 10,8) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość wolframu\nZakres:\nfrakcja wdychalna Stężenie/ zawartość wolframu i jego związków nierozpuszczalnych - w przeliczeniu na W Stężenie/ zawartość wolframu i jego związków rozpuszczalnych - w przeliczeniu na W\nZakres (0,035 – 15,0) mg/m3\nZakres (0,025 – 10,8) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość wolframu\nZakres:\nfrakcja wdychalna Stężenie/ zawartość wolframu i jego związków nierozpuszczalnych - w przeliczeniu na W Stężenie/ zawartość wolframu i jego związków rozpuszczalnych - w przeliczeniu na W\nZakres (0,035 – 15,0) mg/m3\nZakres (0,025 – 10,8) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc wolframu\nZakres:\nfrakcja wdychalna Stezenie/ zawartosc wolframu i jego zwiazkow nierozpuszczalnych - w przeliczeniu na W Stezenie/ zawartosc wolframu i jego zwiazkow rozpuszczalnych - w przeliczeniu na W\nZakres (0,035 – 15,0) mg/m3\nZakres (0,025 – 10,8) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of tungsten","parameters_en":[{"name":"inhalable fraction Concentration/ content of tungsten and its insoluble compounds - expressed as W Concentration/ content of tungsten and its soluble compounds - expressed as W"},{"name":"Range","range":"(0,035 – 15,0) mg/m3"},{"name":"Range","range":"(0,025 – 10,8) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of tungsten Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Concentration/ content of tungsten and its insoluble compounds - expressed as W Concentration/ content of tungsten and its soluble compounds - expressed as W Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"frakcja wdychalna Stężenie/ zawartość wolframu i jego związków nierozpuszczalnych - w przeliczeniu na W Stężenie/ zawartość wolframu i jego związków rozpuszczalnych - w przeliczeniu na W"},{"name":"范围","range":"(0,035 – 15,0) mg/m3"},{"name":"范围","range":"(0,025 – 10,8) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e7","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość wodorku litu","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0008 – 0,20) mg/m3"},{"name":"Zakres","range":"(0,0006 – 0,144) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość wodorku litu\nZakres:\nfrakcja wdychalna\nZakres (0,0008 – 0,20) mg/m3\nZakres (0,0006 – 0,144) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość wodorku litu\nZakres:\nfrakcja wdychalna\nZakres (0,0008 – 0,20) mg/m3\nZakres (0,0006 – 0,144) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc wodorku litu\nZakres:\nfrakcja wdychalna\nZakres (0,0008 – 0,20) mg/m3\nZakres (0,0006 – 0,144) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of lithium hydride","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0008 – 0,20) mg/m3"},{"name":"Range","range":"(0,0006 – 0,144) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of lithium hydride Microwave plasma atomic emission spectrometry (MP-AES) inhalable fraction Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0008 – 0,20) mg/m3"},{"name":"范围","range":"(0,0006 – 0,144) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 可吸入组分 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e8","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość cyrkonu i jego związków – w przeliczeniu na Zr","parameters":[{"name":"Zakres","range":"(0,0694 – 20,0) mg/m3"},{"name":"Zakres","range":"(0,050 – 14,4) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość cyrkonu i jego związków – w przeliczeniu na Zr\nZakres:\nZakres (0,0694 – 20,0) mg/m3\nZakres (0,050 – 14,4) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość cyrkonu i jego związków – w przeliczeniu na Zr\nZakres:\nZakres (0,0694 – 20,0) mg/m3\nZakres (0,050 – 14,4) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc cyrkonu i jego zwiazkow – w przeliczeniu na Zr\nZakres:\nZakres (0,0694 – 20,0) mg/m3\nZakres (0,050 – 14,4) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of zirconium and its compounds – calculated as Zr","parameters_en":[{"name":"Range","range":"(0,0694 – 20,0) mg/m3"},{"name":"Range","range":"(0,050 – 14,4) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of zirconium and its compounds – calculated as Zr Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0694 – 20,0) mg/m3"},{"name":"范围","range":"(0,050 – 14,4) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205e9","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość molibdenu i jego związków – w przeliczeniu na Mo","parameters":[{"name":"Zakres","range":"(0,0694 – 20,0) mg/m3"},{"name":"Zakres","range":"(0,050 – 14,4) mg w próbce"}],"technique":"Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","techniques":["Metoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)"],"computed":[],"activity":"Stężenie/ zawartość molibdenu i jego związków – w przeliczeniu na Mo\nZakres:\nZakres (0,0694 – 20,0) mg/m3\nZakres (0,050 – 14,4) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES)","reference":"PB-06/08 wydanie 3 z dnia 06.01.2025 r.","norm_bases":["PB-06/08 wydanie 3 z dnia 06.01.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość molibdenu i jego związków – w przeliczeniu na Mo\nZakres:\nZakres (0,0694 – 20,0) mg/m3\nZakres (0,050 – 14,4) mg w próbce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc molibdenu i jego zwiazkow – w przeliczeniu na Mo\nZakres:\nZakres (0,0694 – 20,0) mg/m3\nZakres (0,050 – 14,4) mg w probce\nMetoda spektrometrii emisyjnej z wzbudzeniem w mikrofalowej plazmie azotowej (MP-AES) PB-06/08 wydanie 3 z dnia 06.01.2025 r.","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of molybdenum and its compounds – calculated as Mo","parameters_en":[{"name":"Range","range":"(0,0694 – 20,0) mg/m3"},{"name":"Range","range":"(0,050 – 14,4) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of molybdenum and its compounds – calculated as Mo Microwave plasma atomic emission spectrometry (MP-AES) Range Range PB-06/08 wydanie 3 z dnia 06.01.2025 r.","technique_en":"Microwave plasma atomic emission spectrometry (MP-AES)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0694 – 20,0) mg/m3"},{"name":"范围","range":"(0,050 – 14,4) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 微波等离子体原子发射光谱法（MP-AES） 范围 范围 PB-06/08 wydanie 3 z dnia 06.01.2025 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"微波等离子体原子发射光谱法（MP-AES）"},{"_id":"6a83afc0af14b9c0e7b205ea","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,0625 – 19,1) mg/m3"},{"name":"Zakres","range":"(0,0193 – 5,88) ppm"},{"name":"Zakres","range":"(0,0018 – 0,80) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość benzenu\nZakres:\nZakres (0,0625 – 19,1) mg/m3\nZakres (0,0193 – 5,88) ppm\nZakres (0,0018 – 0,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość benzenu\nZakres:\nZakres (0,0625 – 19,1) mg/m3\nZakres (0,0193 – 5,88) ppm\nZakres (0,0018 – 0,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc benzenu\nZakres:\nZakres (0,0625 – 19,1) mg/m3\nZakres (0,0193 – 5,88) ppm\nZakres (0,0018 – 0,80) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of benzene","parameters_en":[{"name":"Range","range":"(0,0625 – 19,1) mg/m3"},{"name":"Range","range":"(0,0193 – 5,88) ppm"},{"name":"Range","range":"(0,0018 – 0,80) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of benzene Gas chromatography with flame ionization detection (GC-FID) Range Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0625 – 19,1) mg/m3"},{"name":"范围","range":"(0,0193 – 5,88) ppm"},{"name":"范围","range":"(0,0018 – 0,80) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205eb","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość toluenu","parameters":[{"name":"Zakres","range":"(3,47 – 571) mg/m3"},{"name":"Zakres","range":"(0,100 – 10,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość toluenu\nZakres:\nZakres (3,47 – 571) mg/m3\nZakres (0,100 – 10,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość toluenu\nZakres:\nZakres (3,47 – 571) mg/m3\nZakres (0,100 – 10,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc toluenu\nZakres:\nZakres (3,47 – 571) mg/m3\nZakres (0,100 – 10,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of toluene","parameters_en":[{"name":"Range","range":"(3,47 – 571) mg/m3"},{"name":"Range","range":"(0,100 – 10,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of toluene Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(3,47 – 571) mg/m3"},{"name":"范围","range":"(0,100 – 10,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205ec","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość octanu n- butylu","parameters":[{"name":"Zakres","range":"(1,39 – 1900) mg/m3"},{"name":"Zakres","range":"(0,040 – 11,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość octanu n- butylu\nZakres:\nZakres (1,39 – 1900) mg/m3\nZakres (0,040 – 11,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość octanu n- butylu\nZakres:\nZakres (1,39 – 1900) mg/m3\nZakres (0,040 – 11,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc octanu n- butylu\nZakres:\nZakres (1,39 – 1900) mg/m3\nZakres (0,040 – 11,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of n- butyl acetate","parameters_en":[{"name":"Range","range":"(1,39 – 1900) mg/m3"},{"name":"Range","range":"(0,040 – 11,2) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of n- butyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 1900) mg/m3"},{"name":"范围","range":"(0,040 – 11,2) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205ed","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość octanu etylu","parameters":[{"name":"Zakres","range":"(1,39 – 3000) mg/m3"},{"name":"Zakres","range":"(0,379 – 818,5) ppm"},{"name":"Zakres","range":"(0,040 – 12,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość octanu etylu\nZakres:\nZakres (1,39 – 3000) mg/m3\nZakres (0,379 – 818,5) ppm\nZakres (0,040 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość octanu etylu\nZakres:\nZakres (1,39 – 3000) mg/m3\nZakres (0,379 – 818,5) ppm\nZakres (0,040 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc octanu etylu\nZakres:\nZakres (1,39 – 3000) mg/m3\nZakres (0,379 – 818,5) ppm\nZakres (0,040 – 12,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of ethyl acetate","parameters_en":[{"name":"Range","range":"(1,39 – 3000) mg/m3"},{"name":"Range","range":"(0,379 – 818,5) ppm"},{"name":"Range","range":"(0,040 – 12,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of ethyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 3000) mg/m3"},{"name":"范围","range":"(0,379 – 818,5) ppm"},{"name":"范围","range":"(0,040 – 12,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205ee","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość styrenu","parameters":[{"name":"Zakres","range":"(3,47 – 1048) mg/m3"},{"name":"Zakres","range":"(0,100 – 15,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość styrenu\nZakres:\nZakres (3,47 – 1048) mg/m3\nZakres (0,100 – 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość styrenu\nZakres:\nZakres (3,47 – 1048) mg/m3\nZakres (0,100 – 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc styrenu\nZakres:\nZakres (3,47 – 1048) mg/m3\nZakres (0,100 – 15,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of styrene","parameters_en":[{"name":"Range","range":"(3,47 – 1048) mg/m3"},{"name":"Range","range":"(0,100 – 15,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of styrene Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(3,47 – 1048) mg/m3"},{"name":"范围","range":"(0,100 – 15,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205ef","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość ksylenu (mieszanina izomerów)","parameters":[{"name":"Zakres","range":"(1,39 – 250) mg/m3"},{"name":"Zakres","range":"(0,040 – 6,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość ksylenu (mieszanina izomerów)\nZakres:\nZakres (1,39 – 250) mg/m3\nZakres (0,040 – 6,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość ksylenu (mieszanina izomerów)\nZakres:\nZakres (1,39 – 250) mg/m3\nZakres (0,040 – 6,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc ksylenu (mieszanina izomerow)\nZakres:\nZakres (1,39 – 250) mg/m3\nZakres (0,040 – 6,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of xylene (mixture of isomers)","parameters_en":[{"name":"Range","range":"(1,39 – 250) mg/m3"},{"name":"Range","range":"(0,040 – 6,40) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of xylene (mixture of isomers) Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 250) mg/m3"},{"name":"范围","range":"(0,040 – 6,40) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f0","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość acetonu","parameters":[{"name":"Zakres","range":"(1,04 – 3600) mg/m3"},{"name":"Zakres","range":"(0,030 – 14,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość acetonu\nZakres:\nZakres (1,04 – 3600) mg/m3\nZakres (0,030 – 14,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość acetonu\nZakres:\nZakres (1,04 – 3600) mg/m3\nZakres (0,030 – 14,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc acetonu\nZakres:\nZakres (1,04 – 3600) mg/m3\nZakres (0,030 – 14,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of acetone","parameters_en":[{"name":"Range","range":"(1,04 – 3600) mg/m3"},{"name":"Range","range":"(0,030 – 14,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of acetone Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,04 – 3600) mg/m3"},{"name":"范围","range":"(0,030 – 14,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f1","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość butan-1-olu","parameters":[{"name":"Zakres","range":"(1,39 – 619) mg/m3"},{"name":"Zakres","range":"(0,040 – 12,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość butan-1-olu\nZakres:\nZakres (1,39 – 619) mg/m3\nZakres (0,040 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość butan-1-olu\nZakres:\nZakres (1,39 – 619) mg/m3\nZakres (0,040 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc butan-1-olu\nZakres:\nZakres (1,39 – 619) mg/m3\nZakres (0,040 – 12,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of butan-1-ol","parameters_en":[{"name":"Range","range":"(1,39 – 619) mg/m3"},{"name":"Range","range":"(0,040 – 12,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of butan-1-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 619) mg/m3"},{"name":"范围","range":"(0,040 – 12,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f2","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość cykloheksanu","parameters":[{"name":"Zakres","range":"(2,78– 2000) mg/m3"},{"name":"Zakres","range":"(0,080– 15,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość cykloheksanu\nZakres:\nZakres (2,78– 2000) mg/m3\nZakres (0,080– 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość cykloheksanu\nZakres:\nZakres (2,78– 2000) mg/m3\nZakres (0,080– 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc cykloheksanu\nZakres:\nZakres (2,78– 2000) mg/m3\nZakres (0,080– 15,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of cyclohexane","parameters_en":[{"name":"Range","range":"(2,78– 2000) mg/m3"},{"name":"Range","range":"(0,080– 15,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of cyclohexane Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(2,78– 2000) mg/m3"},{"name":"范围","range":"(0,080– 15,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f3","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość butan-2-olu","parameters":[{"name":"Zakres","range":"(2,08 – 900) mg/m3"},{"name":"Zakres","range":"(0,060 –15,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość butan-2-olu\nZakres:\nZakres (2,08 – 900) mg/m3\nZakres (0,060 –15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość butan-2-olu\nZakres:\nZakres (2,08 – 900) mg/m3\nZakres (0,060 –15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc butan-2-olu\nZakres:\nZakres (2,08 – 900) mg/m3\nZakres (0,060 –15,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of butan-2-ol","parameters_en":[{"name":"Range","range":"(2,08 – 900) mg/m3"},{"name":"Range","range":"(0,060 –15,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of butan-2-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(2,08 – 900) mg/m3"},{"name":"范围","range":"(0,060 –15,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f4","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 2-butoksyetanolu","parameters":[{"name":"Zakres","range":"(1,39 – 400) mg/m3"},{"name":"Zakres","range":"(0,040 – 8,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 2-butoksyetanolu\nZakres:\nZakres (1,39 – 400) mg/m3\nZakres (0,040 – 8,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 2-butoksyetanolu\nZakres:\nZakres (1,39 – 400) mg/m3\nZakres (0,040 – 8,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 2-butoksyetanolu\nZakres:\nZakres (1,39 – 400) mg/m3\nZakres (0,040 – 8,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 2-butoxyethanol","parameters_en":[{"name":"Range","range":"(1,39 – 400) mg/m3"},{"name":"Range","range":"(0,040 – 8,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 2-butoxyethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 400) mg/m3"},{"name":"范围","range":"(0,040 – 8,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f5","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość octanu 2-butoksyetylu","parameters":[{"name":"Zakres","range":"(0,694 – 600) mg/m3"},{"name":"Zakres","range":"(0,020 – 12,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość octanu 2-butoksyetylu\nZakres:\nZakres (0,694 – 600) mg/m3\nZakres (0,020 – 12,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość octanu 2-butoksyetylu\nZakres:\nZakres (0,694 – 600) mg/m3\nZakres (0,020 – 12,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc octanu 2-butoksyetylu\nZakres:\nZakres (0,694 – 600) mg/m3\nZakres (0,020 – 12,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 2-butoxyethyl acetate","parameters_en":[{"name":"Range","range":"(0,694 – 600) mg/m3"},{"name":"Range","range":"(0,020 – 12,6) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 2-butoxyethyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,694 – 600) mg/m3"},{"name":"范围","range":"(0,020 – 12,6) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f6","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość butan-2-onu","parameters":[{"name":"Zakres","range":"(1,74 – 1800) mg/m3"},{"name":"Zakres","range":"(0,050 – 9,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość butan-2-onu\nZakres:\nZakres (1,74 – 1800) mg/m3\nZakres (0,050 – 9,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość butan-2-onu\nZakres:\nZakres (1,74 – 1800) mg/m3\nZakres (0,050 – 9,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc butan-2-onu\nZakres:\nZakres (1,74 – 1800) mg/m3\nZakres (0,050 – 9,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of butan-2-one","parameters_en":[{"name":"Range","range":"(1,74 – 1800) mg/m3"},{"name":"Range","range":"(0,050 – 9,50) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of butan-2-one Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 – 1800) mg/m3"},{"name":"范围","range":"(0,050 – 9,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f7","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość etylobenzenu","parameters":[{"name":"Zakres","range":"(1,74 – 800) mg/m3"},{"name":"Zakres","range":"(0,050 – 15,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość etylobenzenu\nZakres:\nZakres (1,74 – 800) mg/m3\nZakres (0,050 – 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość etylobenzenu\nZakres:\nZakres (1,74 – 800) mg/m3\nZakres (0,050 – 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc etylobenzenu\nZakres:\nZakres (1,74 – 800) mg/m3\nZakres (0,050 – 15,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of ethylbenzene","parameters_en":[{"name":"Range","range":"(1,74 – 800) mg/m3"},{"name":"Range","range":"(0,050 – 15,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of ethylbenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 – 800) mg/m3"},{"name":"范围","range":"(0,050 – 15,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f8","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość etylotoluenu - mieszanina izomerów","parameters":[{"name":"Zakres","range":"(1,74 – 200) mg/m3"},{"name":"Zakres","range":"(0,050 – 8,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość etylotoluenu - mieszanina izomerów\nZakres:\nZakres (1,74 – 200) mg/m3\nZakres (0,050 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość etylotoluenu - mieszanina izomerów\nZakres:\nZakres (1,74 – 200) mg/m3\nZakres (0,050 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc etylotoluenu - mieszanina izomerow\nZakres:\nZakres (1,74 – 200) mg/m3\nZakres (0,050 – 8,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of ethyltoluene - mixture of isomers","parameters_en":[{"name":"Range","range":"(1,74 – 200) mg/m3"},{"name":"Range","range":"(0,050 – 8,40) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of ethyltoluene - mixture of isomers Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 – 200) mg/m3"},{"name":"范围","range":"(0,050 – 8,40) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205f9","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 2-aminoetanolu","parameters":[{"name":"Zakres","range":"(0,24 – 15,0) mg/m3"},{"name":"Zakres","range":"(0,0070 – 0,30) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 2-aminoetanolu\nZakres:\nZakres (0,24 – 15,0) mg/m3\nZakres (0,0070 – 0,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 2-aminoetanolu\nZakres:\nZakres (0,24 – 15,0) mg/m3\nZakres (0,0070 – 0,30) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 2-aminoetanolu\nZakres:\nZakres (0,24 – 15,0) mg/m3\nZakres (0,0070 – 0,30) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 2-aminoethanol","parameters_en":[{"name":"Range","range":"(0,24 – 15,0) mg/m3"},{"name":"Range","range":"(0,0070 – 0,30) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 2-aminoethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,24 – 15,0) mg/m3"},{"name":"范围","range":"(0,0070 – 0,30) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205fa","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(1,39 – 60,0) mg/m3"},{"name":"Zakres","range":"(0,040 – 2,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość glikolu etylenowego\nZakres:\nZakres (1,39 – 60,0) mg/m3\nZakres (0,040 – 2,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość glikolu etylenowego\nZakres:\nZakres (1,39 – 60,0) mg/m3\nZakres (0,040 – 2,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc glikolu etylenowego\nZakres:\nZakres (1,39 – 60,0) mg/m3\nZakres (0,040 – 2,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of ethylene glycol","parameters_en":[{"name":"Range","range":"(1,39 – 60,0) mg/m3"},{"name":"Range","range":"(0,040 – 2,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of ethylene glycol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 60,0) mg/m3"},{"name":"范围","range":"(0,040 – 2,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205fb","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(1,74 – 3000) mg/m3"},{"name":"Zakres","range":"(0,050 – 18,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (1,74 – 3000) mg/m3\nZakres (0,050 – 18,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (1,74 – 3000) mg/m3\nZakres (0,050 – 18,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc benzyny ekstrakcyjnej\nZakres:\nZakres (1,74 – 3000) mg/m3\nZakres (0,050 – 18,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of extraction naphtha","parameters_en":[{"name":"Range","range":"(1,74 – 3000) mg/m3"},{"name":"Range","range":"(0,050 – 18,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of extraction naphtha Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 – 3000) mg/m3"},{"name":"范围","range":"(0,050 – 18,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205fc","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość benzyny do lakierów","parameters":[{"name":"Zakres","range":"(5,21 – 1800) mg/m3"},{"name":"Zakres","range":"(0,150 – 18,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość benzyny do lakierów\nZakres:\nZakres (5,21 – 1800) mg/m3\nZakres (0,150 – 18,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość benzyny do lakierów\nZakres:\nZakres (5,21 – 1800) mg/m3\nZakres (0,150 – 18,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc benzyny do lakierow\nZakres:\nZakres (5,21 – 1800) mg/m3\nZakres (0,150 – 18,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment","automotive"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of white spirit","parameters_en":[{"name":"Range","range":"(5,21 – 1800) mg/m3"},{"name":"Range","range":"(0,150 – 18,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of white spirit Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(5,21 – 1800) mg/m3"},{"name":"范围","range":"(0,150 – 18,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205fd","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość heksanu","parameters":[{"name":"Zakres","range":"(3,47 – 140) mg/m3"},{"name":"Zakres","range":"(0,100 – 5,80) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość heksanu\nZakres:\nZakres (3,47 – 140) mg/m3\nZakres (0,100 – 5,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość heksanu\nZakres:\nZakres (3,47 – 140) mg/m3\nZakres (0,100 – 5,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc heksanu\nZakres:\nZakres (3,47 – 140) mg/m3\nZakres (0,100 – 5,80) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of hexane","parameters_en":[{"name":"Range","range":"(3,47 – 140) mg/m3"},{"name":"Range","range":"(0,100 – 5,80) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of hexane Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(3,47 – 140) mg/m3"},{"name":"范围","range":"(0,100 – 5,80) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205fe","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość propan-1-olu","parameters":[{"name":"Zakres","range":"(1,39 – 1200) mg/m3"},{"name":"Zakres","range":"(0,040 – 12,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość propan-1-olu\nZakres:\nZakres (1,39 – 1200) mg/m3\nZakres (0,040 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość propan-1-olu\nZakres:\nZakres (1,39 – 1200) mg/m3\nZakres (0,040 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc propan-1-olu\nZakres:\nZakres (1,39 – 1200) mg/m3\nZakres (0,040 – 12,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of propan-1-ol","parameters_en":[{"name":"Range","range":"(1,39 – 1200) mg/m3"},{"name":"Range","range":"(0,040 – 12,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of propan-1-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 1200) mg/m3"},{"name":"范围","range":"(0,040 – 12,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b205ff","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość propan-2-olu","parameters":[{"name":"Zakres","range":"(1,39 – 2400) mg/m3"},{"name":"Zakres","range":"(0,040 – 11,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość propan-2-olu\nZakres:\nZakres (1,39 – 2400) mg/m3\nZakres (0,040 – 11,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość propan-2-olu\nZakres:\nZakres (1,39 – 2400) mg/m3\nZakres (0,040 – 11,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc propan-2-olu\nZakres:\nZakres (1,39 – 2400) mg/m3\nZakres (0,040 – 11,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of propan-2-ol","parameters_en":[{"name":"Range","range":"(1,39 – 2400) mg/m3"},{"name":"Range","range":"(0,040 – 11,50) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of propan-2-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 2400) mg/m3"},{"name":"范围","range":"(0,040 – 11,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20600","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość octanu 2–metoksy-1-metyloetylu","parameters":[{"name":"Zakres","range":"(5,21 – 1040) mg/m3"},{"name":"Zakres","range":"(0,150 – 22,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość octanu 2–metoksy-1-metyloetylu\nZakres:\nZakres (5,21 – 1040) mg/m3\nZakres (0,150 – 22,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość octanu 2–metoksy-1-metyloetylu\nZakres:\nZakres (5,21 – 1040) mg/m3\nZakres (0,150 – 22,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc octanu 2–metoksy-1-metyloetylu\nZakres:\nZakres (5,21 – 1040) mg/m3\nZakres (0,150 – 22,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 2–methoxy-1-methylethyl acetate","parameters_en":[{"name":"Range","range":"(5,21 – 1040) mg/m3"},{"name":"Range","range":"(0,150 – 22,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 2–methoxy-1-methylethyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(5,21 – 1040) mg/m3"},{"name":"范围","range":"(0,150 – 22,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20601","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 1-metoksy-2-propanolu","parameters":[{"name":"Zakres","range":"(1,74 – 720) mg/m3"},{"name":"Zakres","range":"(0,050 – 15,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 1-metoksy-2-propanolu\nZakres:\nZakres (1,74 – 720) mg/m3\nZakres (0,050 – 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 1-metoksy-2-propanolu\nZakres:\nZakres (1,74 – 720) mg/m3\nZakres (0,050 – 15,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 1-metoksy-2-propanolu\nZakres:\nZakres (1,74 – 720) mg/m3\nZakres (0,050 – 15,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 1-methoxy-2-propanol","parameters_en":[{"name":"Range","range":"(1,74 – 720) mg/m3"},{"name":"Range","range":"(0,050 – 15,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 1-methoxy-2-propanol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 – 720) mg/m3"},{"name":"范围","range":"(0,050 – 15,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20602","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość trichloroetenu","parameters":[{"name":"Zakres","range":"(1,04 – 200) mg/m3"},{"name":"Zakres","range":"(0,030 – 8,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość trichloroetenu\nZakres:\nZakres (1,04 – 200) mg/m3\nZakres (0,030 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość trichloroetenu\nZakres:\nZakres (1,04 – 200) mg/m3\nZakres (0,030 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc trichloroetenu\nZakres:\nZakres (1,04 – 200) mg/m3\nZakres (0,030 – 8,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of trichloroethene","parameters_en":[{"name":"Range","range":"(1,04 – 200) mg/m3"},{"name":"Range","range":"(0,030 – 8,40) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of trichloroethene Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,04 – 200) mg/m3"},{"name":"范围","range":"(0,030 – 8,40) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20603","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość trimetylobenzenu mieszanina izomerów (1,2,3 -,1,2,4 - i 1,3,5-)","parameters":[{"name":"Zakres","range":"(2,08 – 340) mg/m3"},{"name":"Zakres","range":"(0,060 – 8,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość trimetylobenzenu mieszanina izomerów (1,2,3 -,1,2,4 - i 1,3,5-)\nZakres:\nZakres (2,08 – 340) mg/m3\nZakres (0,060 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość trimetylobenzenu mieszanina izomerów (1,2,3 -,1,2,4 - i 1,3,5-)\nZakres:\nZakres (2,08 – 340) mg/m3\nZakres (0,060 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc trimetylobenzenu mieszanina izomerow (1,2,3 -,1,2,4 - i 1,3,5-)\nZakres:\nZakres (2,08 – 340) mg/m3\nZakres (0,060 – 8,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of trimethylbenzene mixture of isomers (1,2,3 -,1,2,4 - and 1,3,5-)","parameters_en":[{"name":"Range","range":"(2,08 – 340) mg/m3"},{"name":"Range","range":"(0,060 – 8,40) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of trimethylbenzene mixture of isomers (1,2,3 -,1,2,4 - and 1,3,5-) Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(2,08 – 340) mg/m3"},{"name":"范围","range":"(0,060 – 8,40) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20604","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość trichlorobenzenu mieszanina izomerów (1,2,3-, 1,2,4- i 1,3,5-)","parameters":[{"name":"Zakres","range":"(1,04 – 200) mg/m3"},{"name":"Zakres","range":"(0,030 – 8,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość trichlorobenzenu mieszanina izomerów (1,2,3-, 1,2,4- i 1,3,5-)\nZakres:\nZakres (1,04 – 200) mg/m3\nZakres (0,030 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość trichlorobenzenu mieszanina izomerów (1,2,3-, 1,2,4- i 1,3,5-)\nZakres:\nZakres (1,04 – 200) mg/m3\nZakres (0,030 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc trichlorobenzenu mieszanina izomerow (1,2,3-, 1,2,4- i 1,3,5-)\nZakres:\nZakres (1,04 – 200) mg/m3\nZakres (0,030 – 8,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of trichlorobenzene mixture of isomers (1,2,3-, 1,2,4- and 1,3,5-)","parameters_en":[{"name":"Range","range":"(1,04 – 200) mg/m3"},{"name":"Range","range":"(0,030 – 8,40) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of trichlorobenzene mixture of isomers (1,2,3-, 1,2,4- and 1,3,5-) Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,04 – 200) mg/m3"},{"name":"范围","range":"(0,030 – 8,40) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20605","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(1,39 – 340) mg/m3"},{"name":"Zakres","range":"(0,202 – 49,3) ppm"},{"name":"Zakres","range":"(0,040 – 8,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość tetrachloroetenu\nZakres:\nZakres (1,39 – 340) mg/m3\nZakres (0,202 – 49,3) ppm\nZakres (0,040 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość tetrachloroetenu\nZakres:\nZakres (1,39 – 340) mg/m3\nZakres (0,202 – 49,3) ppm\nZakres (0,040 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc tetrachloroetenu\nZakres:\nZakres (1,39 – 340) mg/m3\nZakres (0,202 – 49,3) ppm\nZakres (0,040 – 8,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of tetrachloroethene","parameters_en":[{"name":"Range","range":"(1,39 – 340) mg/m3"},{"name":"Range","range":"(0,202 – 49,3) ppm"},{"name":"Range","range":"(0,040 – 8,40) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of tetrachloroethene Gas chromatography with flame ionization detection (GC-FID) Range Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 340) mg/m3"},{"name":"范围","range":"(0,202 – 49,3) ppm"},{"name":"范围","range":"(0,040 – 8,40) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20606","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 2-metylopropan-1-olu","parameters":[{"name":"Zakres","range":"(1,04 – 400) mg/m3"},{"name":"Zakres","range":"(0,030 – 8,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 2-metylopropan-1-olu\nZakres:\nZakres (1,04 – 400) mg/m3\nZakres (0,030 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 2-metylopropan-1-olu\nZakres:\nZakres (1,04 – 400) mg/m3\nZakres (0,030 – 8,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 2-metylopropan-1-olu\nZakres:\nZakres (1,04 – 400) mg/m3\nZakres (0,030 – 8,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 2-methylpropan-1-ol","parameters_en":[{"name":"Range","range":"(1,04 – 400) mg/m3"},{"name":"Range","range":"(0,030 – 8,40) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 2-methylpropan-1-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,04 – 400) mg/m3"},{"name":"范围","range":"(0,030 – 8,40) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20607","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość cykloheksanonu","parameters":[{"name":"Zakres","range":"(0,69 – 160) mg/m3"},{"name":"Zakres","range":"(0,020 – 7,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość cykloheksanonu\nZakres:\nZakres (0,69 – 160) mg/m3\nZakres (0,020 – 7,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość cykloheksanonu\nZakres:\nZakres (0,69 – 160) mg/m3\nZakres (0,020 – 7,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc cykloheksanonu\nZakres:\nZakres (0,69 – 160) mg/m3\nZakres (0,020 – 7,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of cyclohexanone","parameters_en":[{"name":"Range","range":"(0,69 – 160) mg/m3"},{"name":"Range","range":"(0,020 – 7,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of cyclohexanone Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,69 – 160) mg/m3"},{"name":"范围","range":"(0,020 – 7,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20608","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(1,23 – 100) mg/m3"},{"name":"Zakres","range":"(0,492 – 40,03) ppm"},{"name":"Zakres","range":"(0,060 – 2,52) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość kwasu octowego\nZakres:\nZakres (1,23 – 100) mg/m3\nZakres (0,492 – 40,03) ppm\nZakres (0,060 – 2,52) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość kwasu octowego\nZakres:\nZakres (1,23 – 100) mg/m3\nZakres (0,492 – 40,03) ppm\nZakres (0,060 – 2,52) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc kwasu octowego\nZakres:\nZakres (1,23 – 100) mg/m3\nZakres (0,492 – 40,03) ppm\nZakres (0,060 – 2,52) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of acetic acid","parameters_en":[{"name":"Range","range":"(1,23 – 100) mg/m3"},{"name":"Range","range":"(0,492 – 40,03) ppm"},{"name":"Range","range":"(0,060 – 2,52) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of acetic acid Gas chromatography with flame ionization detection (GC-FID) Range Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,23 – 100) mg/m3"},{"name":"范围","range":"(0,492 – 40,03) ppm"},{"name":"范围","range":"(0,060 – 2,52) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20609","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość octanu winylu","parameters":[{"name":"Zakres","range":"(1,04 – 60,0) mg/m3"},{"name":"Zakres","range":"(0,030 – 2,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość octanu winylu\nZakres:\nZakres (1,04 – 60,0) mg/m3\nZakres (0,030 – 2,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość octanu winylu\nZakres:\nZakres (1,04 – 60,0) mg/m3\nZakres (0,030 – 2,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc octanu winylu\nZakres:\nZakres (1,04 – 60,0) mg/m3\nZakres (0,030 – 2,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of vinyl acetate","parameters_en":[{"name":"Range","range":"(1,04 – 60,0) mg/m3"},{"name":"Range","range":"(0,030 – 2,50) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of vinyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,04 – 60,0) mg/m3"},{"name":"范围","range":"(0,030 – 2,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2060a","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość chloroformu","parameters":[{"name":"Zakres","range":"(0,69 – 50,0) mg/m3"},{"name":"Zakres","range":"(0,020 – 4,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość chloroformu\nZakres:\nZakres (0,69 – 50,0) mg/m3\nZakres (0,020 – 4,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość chloroformu\nZakres:\nZakres (0,69 – 50,0) mg/m3\nZakres (0,020 – 4,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc chloroformu\nZakres:\nZakres (0,69 – 50,0) mg/m3\nZakres (0,020 – 4,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of chloroform","parameters_en":[{"name":"Range","range":"(0,69 – 50,0) mg/m3"},{"name":"Range","range":"(0,020 – 4,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of chloroform Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,69 – 50,0) mg/m3"},{"name":"范围","range":"(0,020 – 4,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2060b","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość nafty","parameters":[{"name":"Zakres","range":"(1,74 –600) mg/m3"},{"name":"Zakres","range":"(0,050 – 9,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość nafty\nZakres:\nZakres (1,74 –600) mg/m3\nZakres (0,050 – 9,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość nafty\nZakres:\nZakres (1,74 –600) mg/m3\nZakres (0,050 – 9,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc nafty\nZakres:\nZakres (1,74 –600) mg/m3\nZakres (0,050 – 9,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of kerosene","parameters_en":[{"name":"Range","range":"(1,74 –600) mg/m3"},{"name":"Range","range":"(0,050 – 9,50) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of kerosene Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 –600) mg/m3"},{"name":"范围","range":"(0,050 – 9,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 煤油的浓度/含量 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"煤油的浓度/含量"},{"_id":"6a83afc0af14b9c0e7b2060c","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 4-metylopentanu-2-onu","parameters":[{"name":"Zakres","range":"(1,39 – 400) mg/m3"},{"name":"Zakres","range":"(0,040 – 17,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 4-metylopentanu-2-onu\nZakres:\nZakres (1,39 – 400) mg/m3\nZakres (0,040 – 17,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 4-metylopentanu-2-onu\nZakres:\nZakres (1,39 – 400) mg/m3\nZakres (0,040 – 17,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 4-metylopentanu-2-onu\nZakres:\nZakres (1,39 – 400) mg/m3\nZakres (0,040 – 17,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 4-methylpentan-2-one","parameters_en":[{"name":"Range","range":"(1,39 – 400) mg/m3"},{"name":"Range","range":"(0,040 – 17,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 4-methylpentan-2-one Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,39 – 400) mg/m3"},{"name":"范围","range":"(0,040 – 17,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2060d","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość metanolu","parameters":[{"name":"Zakres","range":"(5,56 – 600) mg/m3"},{"name":"Zakres","range":"(0,040 – 5,50) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość metanolu\nZakres:\nZakres (5,56 – 600) mg/m3\nZakres (0,040 – 5,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość metanolu\nZakres:\nZakres (5,56 – 600) mg/m3\nZakres (0,040 – 5,50) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc metanolu\nZakres:\nZakres (5,56 – 600) mg/m3\nZakres (0,040 – 5,50) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of methanol","parameters_en":[{"name":"Range","range":"(5,56 – 600) mg/m3"},{"name":"Range","range":"(0,040 – 5,50) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of methanol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(5,56 – 600) mg/m3"},{"name":"范围","range":"(0,040 – 5,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2060e","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość etanolu","parameters":[{"name":"Zakres","range":"(27,50 – 3900) mg/m3"},{"name":"Zakres","range":"(0,055 – 5,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość etanolu\nZakres:\nZakres (27,50 – 3900) mg/m3\nZakres (0,055 – 5,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość etanolu\nZakres:\nZakres (27,50 – 3900) mg/m3\nZakres (0,055 – 5,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc etanolu\nZakres:\nZakres (27,50 – 3900) mg/m3\nZakres (0,055 – 5,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of ethanol","parameters_en":[{"name":"Range","range":"(27,50 – 3900) mg/m3"},{"name":"Range","range":"(0,055 – 5,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of ethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(27,50 – 3900) mg/m3"},{"name":"范围","range":"(0,055 – 5,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2060f","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 1-metylo-2-pirolidonu","parameters":[{"name":"Zakres","range":"(2,78 – 200) mg/m3"},{"name":"Zakres","range":"(0,674 – 48,5) ppm"},{"name":"Zakres","range":"(0,050 – 5,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 1-metylo-2-pirolidonu\nZakres:\nZakres (2,78 – 200) mg/m3\nZakres (0,674 – 48,5) ppm\nZakres (0,050 – 5,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 1-metylo-2-pirolidonu\nZakres:\nZakres (2,78 – 200) mg/m3\nZakres (0,674 – 48,5) ppm\nZakres (0,050 – 5,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 1-metylo-2-pirolidonu\nZakres:\nZakres (2,78 – 200) mg/m3\nZakres (0,674 – 48,5) ppm\nZakres (0,050 – 5,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 1-methyl-2-pyrrolidone","parameters_en":[{"name":"Range","range":"(2,78 – 200) mg/m3"},{"name":"Range","range":"(0,674 – 48,5) ppm"},{"name":"Range","range":"(0,050 – 5,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 1-methyl-2-pyrrolidone Gas chromatography with flame ionization detection (GC-FID) Range Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(2,78 – 200) mg/m3"},{"name":"范围","range":"(0,674 – 48,5) ppm"},{"name":"范围","range":"(0,050 – 5,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20610","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 4-hydroksy-4-metylopentan-2-onu","parameters":[{"name":"Zakres","range":"(5,55 – 600) mg/m3"},{"name":"Zakres","range":"(0,100 – 12,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 4-hydroksy-4-metylopentan-2-onu\nZakres:\nZakres (5,55 – 600) mg/m3\nZakres (0,100 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 4-hydroksy-4-metylopentan-2-onu\nZakres:\nZakres (5,55 – 600) mg/m3\nZakres (0,100 – 12,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 4-hydroksy-4-metylopentan-2-onu\nZakres:\nZakres (5,55 – 600) mg/m3\nZakres (0,100 – 12,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 4-hydroxy-4-methylpentan-2-one","parameters_en":[{"name":"Range","range":"(5,55 – 600) mg/m3"},{"name":"Range","range":"(0,100 – 12,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 4-hydroxy-4-methylpentan-2-one Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(5,55 – 600) mg/m3"},{"name":"范围","range":"(0,100 – 12,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20611","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość 2-(2-butoksyetoksy) etanolu","parameters":[{"name":"Zakres","range":"(2,78 – 200) mg/m3"},{"name":"Zakres","range":"(0,050 – 6,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (2,78 – 200) mg/m3\nZakres (0,050 – 6,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (2,78 – 200) mg/m3\nZakres (0,050 – 6,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc 2-(2-butoksyetoksy) etanolu\nZakres:\nZakres (2,78 – 200) mg/m3\nZakres (0,050 – 6,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of 2-(2-butoxyethoxy) ethanol","parameters_en":[{"name":"Range","range":"(2,78 – 200) mg/m3"},{"name":"Range","range":"(0,050 – 6,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of 2-(2-butoxyethoxy) ethanol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(2,78 – 200) mg/m3"},{"name":"范围","range":"(0,050 – 6,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20612","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość heptanu","parameters":[{"name":"Zakres","range":"(1,74 –4000) mg/m3"},{"name":"Zakres","range":"(0,050 – 18,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość heptanu\nZakres:\nZakres (1,74 –4000) mg/m3\nZakres (0,050 – 18,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość heptanu\nZakres:\nZakres (1,74 –4000) mg/m3\nZakres (0,050 – 18,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc heptanu\nZakres:\nZakres (1,74 –4000) mg/m3\nZakres (0,050 – 18,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of heptane","parameters_en":[{"name":"Range","range":"(1,74 –4000) mg/m3"},{"name":"Range","range":"(0,050 – 18,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of heptane Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 –4000) mg/m3"},{"name":"范围","range":"(0,050 – 18,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20613","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość chlorobenzenu","parameters":[{"name":"Zakres","range":"(1,74 – 200) mg/m3"},{"name":"Zakres","range":"(0,050 – 3,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/ zawartość chlorobenzenu\nZakres:\nZakres (1,74 – 200) mg/m3\nZakres (0,050 – 3,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PB-06/09 wydanie 2 z dnia 20.11.2023 r.","norm_bases":["PB-06/09 wydanie 2 z dnia 20.11.2023 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość chlorobenzenu\nZakres:\nZakres (1,74 – 200) mg/m3\nZakres (0,050 – 3,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r. Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc chlorobenzenu\nZakres:\nZakres (1,74 – 200) mg/m3\nZakres (0,050 – 3,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PB-06/09 wydanie 2 z dnia 20.11.2023 r.","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of chlorobenzene","parameters_en":[{"name":"Range","range":"(1,74 – 200) mg/m3"},{"name":"Range","range":"(0,050 – 3,00) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of chlorobenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,74 – 200) mg/m3"},{"name":"范围","range":"(0,050 – 3,00) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 气相色谱-火焰离子化检测法（GC-FID） 范围 范围 PB-06/09 wydanie 2 z dnia 20.11.2023 r.","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20614","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie/ zawartość oleju mineralnego wysokorafinowanego z wyłączeniem cieczy obróbkowych","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,42 – 20,8) mg/m3"},{"name":"Zakres","range":"(0,30 – 7,2) mg w próbce"}],"technique":"Metoda spektrometrii absorpcyjnej w nadfiolecie","techniques":["Metoda spektrometrii absorpcyjnej w nadfiolecie"],"computed":[],"activity":"Stężenie/ zawartość oleju mineralnego wysokorafinowanego z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,42 – 20,8) mg/m3\nZakres (0,30 – 7,2) mg w próbce\nMetoda spektrometrii absorpcyjnej w nadfiolecie","reference":"PN-Z-04108-6:2006 + Az1:2009","norm_bases":["PN-Z-04108-6:2006 + Az1:2009"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie/ zawartość oleju mineralnego wysokorafinowanego z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,42 – 20,8) mg/m3\nZakres (0,30 – 7,2) mg w próbce\nMetoda spektrometrii absorpcyjnej w nadfiolecie PN-Z-04108-6:2006 + Az1:2009 Srodowisko pracy – powietrze – probki powietrza Stezenie/ zawartosc oleju mineralnego wysokorafinowanego z wylaczeniem cieczy obrobkowych\nZakres:\nfrakcja wdychalna\nZakres (0,42 – 20,8) mg/m3\nZakres (0,30 – 7,2) mg w probce\nMetoda spektrometrii absorpcyjnej w nadfiolecie PN-Z-04108-6:2006 + Az1:2009","categories":["environment","petro"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/ content of highly refined mineral oil excluding metalworking fluids","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,42 – 20,8) mg/m3"},{"name":"Range","range":"(0,30 – 7,2) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration/ content of highly refined mineral oil excluding metalworking fluids Ultraviolet absorption spectrometry method inhalable fraction Range Range PN-Z-04108-6:2006 + Az1:2009","technique_en":"Ultraviolet absorption spectrometry method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,42 – 20,8) mg/m3"},{"name":"范围","range":"(0,30 – 7,2) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 紫外吸收光谱法 可吸入组分 范围 范围 PN-Z-04108-6:2006 + Az1:2009","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"紫外吸收光谱法"},{"_id":"6a83afc0af14b9c0e7b20615","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(1,30 – 40,0) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (1,30 – 40,0) mg/m3\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie amoniaku\nZakres (1,30 – 40,0) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy – powietrze – probki powietrza Stezenie amoniaku\nZakres (1,30 – 40,0) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(1,30 – 40,0) mg/m3"}],"search_en":"Workplace environment – air – air samples Ammonia concentration Spectrophotometric method Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(1,30 – 40,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 氨浓度 分光光度法 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"氨浓度"},{"_id":"6a83afc0af14b9c0e7b20616","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie tritlenku siarki","parameters":[{"name":"Zakres","range":"(0,092 – 7,0) mg/m3"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie tritlenku siarki\nZakres (0,092 – 7,0) mg/m3\nMetoda turbidymetryczna","reference":"PN-91/Z-04056/02","norm_bases":["PN-91/Z-04056/02"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie tritlenku siarki\nZakres (0,092 – 7,0) mg/m3\nMetoda turbidymetryczna PN-91/Z-04056/02 Srodowisko pracy – powietrze – probki powietrza Stezenie tritlenku siarki\nZakres (0,092 – 7,0) mg/m3\nMetoda turbidymetryczna PN-91/Z-04056/02","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur trioxide concentration","parameters_en":[{"name":"Range","range":"(0,092 – 7,0) mg/m3"}],"search_en":"Workplace environment – air – air samples Sulfur trioxide concentration Turbidimetric method Range PN-91/Z-04056/02","technique_en":"Turbidimetric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,092 – 7,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 浊度法 范围 PN-91/Z-04056/02","test_object_zh":"工作场所环境 — 空气 — 空气样品","technique_zh":"浊度法"},{"_id":"6a83afc0af14b9c0e7b20617","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie chloru","parameters":[{"name":"Zakres","range":"(0,0625 – 3,00) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru\nZakres (0,0625 – 3,00) mg/m3\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03 z wyłączeniem pkt. 5d","norm_bases":["PN-75/Z-04037/03 z wyłączeniem pkt. 5d"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie chloru\nZakres (0,0625 – 3,00) mg/m3\nMetoda spektrofotometryczna PN-75/Z-04037/03 z wyłączeniem pkt. 5d Srodowisko pracy – powietrze – probki powietrza Stezenie chloru\nZakres (0,0625 – 3,00) mg/m3\nMetoda spektrofotometryczna PN-75/Z-04037/03 z wylaczeniem pkt. 5d","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration","parameters_en":[{"name":"Range","range":"(0,0625 – 3,00) mg/m3"}],"search_en":"Workplace environment – air – air samples Chlorine concentration Spectrophotometric method Range PN-75/Z-04037/03 z wyłączeniem pkt. 5d","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0625 – 3,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 氯浓度 分光光度法 范围 PN-75/Z-04037/03 z wyłączeniem pkt. 5d","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"氯浓度"},{"_id":"6a83afc0af14b9c0e7b20618","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,0125 – 0,25) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,0125 – 0,25) mg/m3\nMetoda spektrofotometryczna","reference":"PN-94/Z-04007-2","norm_bases":["PN-94/Z-04007-2"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie ozonu\nZakres (0,0125 – 0,25) mg/m3\nMetoda spektrofotometryczna PN-94/Z-04007-2 Srodowisko pracy – powietrze – probki powietrza Stezenie ozonu\nZakres (0,0125 – 0,25) mg/m3\nMetoda spektrofotometryczna PN-94/Z-04007-2","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,0125 – 0,25) mg/m3"}],"search_en":"Workplace environment – air – air samples Ozone concentration Spectrophotometric method Range PN-94/Z-04007-2","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0125 – 0,25) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 臭氧浓度 分光光度法 范围 PN-94/Z-04007-2","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"臭氧浓度"},{"_id":"6a83afc0af14b9c0e7b20619","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie cyjanku sodu, w przeliczeniu na CN","parameters":[{"name":"Zakres","range":"(0,069 – 10) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanku sodu, w przeliczeniu na CN\nZakres (0,069 – 10) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04309: 2002","norm_bases":["PN-Z-04309: 2002"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie cyjanku sodu, w przeliczeniu na CN\nZakres (0,069 – 10) mg/m3\nMetoda spektrofotometryczna PN-Z-04309: 2002 Srodowisko pracy – powietrze – probki powietrza Stezenie cyjanku sodu, w przeliczeniu na CN\nZakres (0,069 – 10) mg/m3\nMetoda spektrofotometryczna PN-Z-04309: 2002","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium cyanide concentration, calculated as CN","parameters_en":[{"name":"Range","range":"(0,069 – 10) mg/m3"}],"search_en":"Workplace environment – air – air samples Sodium cyanide concentration, calculated as CN Spectrophotometric method Range PN-Z-04309: 2002","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,069 – 10) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 分光光度法 范围 PN-Z-04309: 2002","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2061a","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie siarkowodoru","parameters":[{"name":"Zakres","range":"(0,70 – 40) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarkowodoru\nZakres (0,70 – 40) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996 z wyłączeniem pkt. 5c, 5d, 5h","norm_bases":["PN-Z-04015-13:1996 z wyłączeniem pkt. 5c, 5d, 5h"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie siarkowodoru\nZakres (0,70 – 40) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-13:1996 z wyłączeniem pkt. 5c, 5d, 5h Srodowisko pracy – powietrze – probki powietrza Stezenie siarkowodoru\nZakres (0,70 – 40) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-13:1996 z wylaczeniem pkt. 5c, 5d, 5h","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide concentration","parameters_en":[{"name":"Range","range":"(0,70 – 40) mg/m3"}],"search_en":"Workplace environment – air – air samples Hydrogen sulphide concentration Spectrophotometric method Range PN-Z-04015-13:1996 z wyłączeniem pkt. 5c, 5d, 5h","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,70 – 40) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 硫化氢浓度 分光光度法 范围 PN-Z-04015-13:1996 z wyłączeniem pkt. 5c, 5d, 5h","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"硫化氢浓度"},{"_id":"6a83afc0af14b9c0e7b2061b","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie nadtlenku wodoru","parameters":[{"name":"Zakres","range":"(0,040 – 1,6) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie nadtlenku wodoru\nZakres (0,040 – 1,6) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04548:2023-03","norm_bases":["PN-Z-04548:2023-03"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie nadtlenku wodoru\nZakres (0,040 – 1,6) mg/m3\nMetoda spektrofotometryczna PN-Z-04548:2023-03 Srodowisko pracy – powietrze – probki powietrza Stezenie nadtlenku wodoru\nZakres (0,040 – 1,6) mg/m3\nMetoda spektrofotometryczna PN-Z-04548:2023-03","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen peroxide concentration","parameters_en":[{"name":"Range","range":"(0,040 – 1,6) mg/m3"}],"search_en":"Workplace environment – air – air samples Hydrogen peroxide concentration Spectrophotometric method Range PN-Z-04548:2023-03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,040 – 1,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 分光光度法 范围 PN-Z-04548:2023-03","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2061c","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość związków chromu (VI) w przeliczeniu na Cr (VI)","parameters":[{"name":"Zakres","range":"(0,000417– 0,6) mg/m3"},{"name":"Zakres","range":"(0,0003 – 0,432) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość związków chromu (VI) w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,000417– 0,6) mg/m3\nZakres (0,0003 – 0,432) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126/02","norm_bases":["PN-87/Z-04126/02"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość związków chromu (VI) w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,000417– 0,6) mg/m3\nZakres (0,0003 – 0,432) mg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126/02 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc zwiazkow chromu (VI) w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,000417– 0,6) mg/m3\nZakres (0,0003 – 0,432) mg w probce\nMetoda spektrofotometryczna PN-87/Z-04126/02","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of chromium (VI) compounds calculated as Cr (VI)","parameters_en":[{"name":"Range","range":"(0,000417– 0,6) mg/m3"},{"name":"Range","range":"(0,0003 – 0,432) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of chromium (VI) compounds calculated as Cr (VI) Spectrophotometric method Range Range PN-87/Z-04126/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,000417– 0,6) mg/m3"},{"name":"范围","range":"(0,0003 – 0,432) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 分光光度法 范围 范围 PN-87/Z-04126/02","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2061d","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie chlorku amonu – pary i frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,01 – 40,0) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorku amonu – pary i frakcja wdychalna\nZakres (0,01 – 40,0) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04265:2000","norm_bases":["PN-Z-04265:2000"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie chlorku amonu – pary i frakcja wdychalna\nZakres (0,01 – 40,0) mg/m3\nMetoda spektrofotometryczna PN-Z-04265:2000 Srodowisko pracy – powietrze – probki powietrza Stezenie chlorku amonu – pary i frakcja wdychalna\nZakres (0,01 – 40,0) mg/m3\nMetoda spektrofotometryczna PN-Z-04265:2000","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium chloride concentration – vapours and inhalable fraction","parameters_en":[{"name":"Range","range":"(0,01 – 40,0) mg/m3"}],"search_en":"Workplace environment – air – air samples Ammonium chloride concentration – vapours and inhalable fraction Spectrophotometric method Range PN-Z-04265:2000","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,01 – 40,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 分光光度法 范围 PN-Z-04265:2000","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2061e","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,32 – 232) mg/m3"},{"name":"Zakres","range":"(2,0 – 200,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna","reference":"PB-06/10 wydanie 1 z dnia 02.01.2020 r.","norm_bases":["PB-06/10 wydanie 1 z dnia 02.01.2020 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie tlenku węgla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna PB-06/10 wydanie 1 z dnia 02.01.2020 r. Srodowisko pracy – powietrze – probki powietrza Stezenie tlenku wegla\nZakres:\nZakres (2,32 – 232) mg/m3\nZakres (2,0 – 200,0) ppm\nMetoda elektrochemiczna PB-06/10 wydanie 1 z dnia 02.01.2020 r.","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,32 – 232) mg/m3"},{"name":"Range","range":"(2,0 – 200,0) ppm"}],"search_en":"Workplace environment – air – air samples Carbon monoxide concentration Electrochemical method Range Range PB-06/10 wydanie 1 z dnia 02.01.2020 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(2,32 – 232) mg/m3"},{"name":"范围","range":"(2,0 – 200,0) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 一氧化碳浓度 电化学法 范围 范围 PB-06/10 wydanie 1 z dnia 02.01.2020 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"一氧化碳浓度"},{"_id":"6a83afc0af14b9c0e7b2061f","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie tlenku azotu","parameters":[{"name":"Zakres","range":"(0,62 – 25) mg/m3"},{"name":"Zakres","range":"(0,50 – 20,0) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku azotu\nZakres:\nZakres (0,62 – 25) mg/m3\nZakres (0,50 – 20,0) ppm\nMetoda elektrochemiczna","reference":"PB-06/10 wydanie 1 z dnia 02.01.2020 r.","norm_bases":["PB-06/10 wydanie 1 z dnia 02.01.2020 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie tlenku azotu\nZakres:\nZakres (0,62 – 25) mg/m3\nZakres (0,50 – 20,0) ppm\nMetoda elektrochemiczna PB-06/10 wydanie 1 z dnia 02.01.2020 r. Srodowisko pracy – powietrze – probki powietrza Stezenie tlenku azotu\nZakres:\nZakres (0,62 – 25) mg/m3\nZakres (0,50 – 20,0) ppm\nMetoda elektrochemiczna PB-06/10 wydanie 1 z dnia 02.01.2020 r.","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen oxide concentration","parameters_en":[{"name":"Range","range":"(0,62 – 25) mg/m3"},{"name":"Range","range":"(0,50 – 20,0) ppm"}],"search_en":"Workplace environment – air – air samples Nitrogen oxide concentration Electrochemical method Range Range PB-06/10 wydanie 1 z dnia 02.01.2020 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,62 – 25) mg/m3"},{"name":"范围","range":"(0,50 – 20,0) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 一氧化氮浓度 电化学法 范围 范围 PB-06/10 wydanie 1 z dnia 02.01.2020 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"一氧化氮浓度"},{"_id":"6a83afc0af14b9c0e7b20620","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,11 – 29) mg/m3"},{"name":"Zakres","range":"(0,06 – 15,00) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie ditlenku azotu\nZakres:\nZakres (0,11 – 29) mg/m3\nZakres (0,06 – 15,00) ppm\nMetoda elektrochemiczna","reference":"PB-06/10 wydanie 1 z dnia 02.01.2020 r.","norm_bases":["PB-06/10 wydanie 1 z dnia 02.01.2020 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie ditlenku azotu\nZakres:\nZakres (0,11 – 29) mg/m3\nZakres (0,06 – 15,00) ppm\nMetoda elektrochemiczna PB-06/10 wydanie 1 z dnia 02.01.2020 r. Srodowisko pracy – powietrze – probki powietrza Stezenie ditlenku azotu\nZakres:\nZakres (0,11 – 29) mg/m3\nZakres (0,06 – 15,00) ppm\nMetoda elektrochemiczna PB-06/10 wydanie 1 z dnia 02.01.2020 r.","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide concentration","parameters_en":[{"name":"Range","range":"(0,11 – 29) mg/m3"},{"name":"Range","range":"(0,06 – 15,00) ppm"}],"search_en":"Workplace environment – air – air samples Nitrogen dioxide concentration Electrochemical method Range Range PB-06/10 wydanie 1 z dnia 02.01.2020 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,11 – 29) mg/m3"},{"name":"范围","range":"(0,06 – 15,00) ppm"}],"search_zh":"工作场所环境 — 空气 — 空气样品 二氧化氮浓度 电化学法 范围 范围 PB-06/10 wydanie 1 z dnia 02.01.2020 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"二氧化氮浓度"},{"_id":"6a83afc0af14b9c0e7b20621","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PB-06/10 wydanie 1 z dnia 02.01.2020 r.","norm_bases":["PB-06/10 wydanie 1 z dnia 02.01.2020 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Wskaźnik narażenia (z obliczeń) PB-06/10 wydanie 1 z dnia 02.01.2020 r. Srodowisko pracy – powietrze – probki powietrza Wskaznik narazenia (z obliczen) PB-06/10 wydanie 1 z dnia 02.01.2020 r.","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air – air samples Exposure index (calculated) PB-06/10 wydanie 1 z dnia 02.01.2020 r.","test_object_en":"Workplace environment – air – air samples","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 — 空气样品 暴露指数（计算得出） PB-06/10 wydanie 1 z dnia 02.01.2020 r.","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20622","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie fluorków w przeliczeniu na F","parameters":[{"name":"Zakres","range":"(0,014 – 5,0) mg/m3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie fluorków w przeliczeniu na F\nZakres (0,014 – 5,0) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"NIOSH 7906 Method, Issue 2, 20 May 2014","norm_bases":["NIOSH 7906 Method, Issue 2, 20 May 2014"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie fluorków w przeliczeniu na F\nZakres (0,014 – 5,0) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) NIOSH 7906 Method, Issue 2, 20 May 2014 Srodowisko pracy – powietrze – probki powietrza Stezenie fluorkow w przeliczeniu na F\nZakres (0,014 – 5,0) mg/m3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) NIOSH 7906 Method, Issue 2, 20 May 2014","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration calculated as F","parameters_en":[{"name":"Range","range":"(0,014 – 5,0) mg/m3"}],"search_en":"Workplace environment – air – air samples Fluoride concentration calculated as F Ion chromatography with conductometric detection (IC-CD) Range NIOSH 7906 Method, Issue 2, 20 May 2014","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,014 – 5,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 离子色谱-电导检测法（IC-CD） 范围 NIOSH 7906 Method, Issue 2, 20 May 2014","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20623","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie fluorowodoru","parameters":[{"name":"Zakres","range":"(0,015 – 20,0) mg/m3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie fluorowodoru\nZakres (0,015 – 20,0) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"NIOSH 7906 Method, Issue 2, 20 May 2014","norm_bases":["NIOSH 7906 Method, Issue 2, 20 May 2014"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie fluorowodoru\nZakres (0,015 – 20,0) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) NIOSH 7906 Method, Issue 2, 20 May 2014 Srodowisko pracy – powietrze – probki powietrza Stezenie fluorowodoru\nZakres (0,015 – 20,0) mg/m3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) NIOSH 7906 Method, Issue 2, 20 May 2014","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride concentration","parameters_en":[{"name":"Range","range":"(0,015 – 20,0) mg/m3"}],"search_en":"Workplace environment – air – air samples Hydrogen fluoride concentration Ion chromatography with conductometric detection (IC-CD) Range NIOSH 7906 Method, Issue 2, 20 May 2014","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,015 – 20,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 氟化氢浓度 离子色谱-电导检测法（IC-CD） 范围 NIOSH 7906 Method, Issue 2, 20 May 2014","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"氟化氢浓度"},{"_id":"6a83afc0af14b9c0e7b20624","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie chlorowodoru","parameters":[{"name":"Zakres","range":"(0,16 – 20,0) mg/m3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorowodoru\nZakres (0,16 – 20,0) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"NIOSH 7907 Method, Issue 1, 20 May 2014","norm_bases":["NIOSH 7907 Method, Issue 1, 20 May 2014"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie chlorowodoru\nZakres (0,16 – 20,0) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014 Srodowisko pracy – powietrze – probki powietrza Stezenie chlorowodoru\nZakres (0,16 – 20,0) mg/m3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration","parameters_en":[{"name":"Range","range":"(0,16 – 20,0) mg/m3"}],"search_en":"Workplace environment – air – air samples Hydrogen chloride concentration Ion chromatography with conductometric detection (IC-CD) Range NIOSH 7907 Method, Issue 1, 20 May 2014","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,16 – 20,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 氯化氢浓度 离子色谱-电导检测法（IC-CD） 范围 NIOSH 7907 Method, Issue 1, 20 May 2014","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"氯化氢浓度"},{"_id":"6a83afc0af14b9c0e7b20625","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie kwasu azotowego","parameters":[{"name":"Zakres","range":"(0,10 – 5,60) mg/m3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kwasu azotowego\nZakres (0,10 – 5,60) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"NIOSH 7907 Method, Issue 1, 20 May 2014","norm_bases":["NIOSH 7907 Method, Issue 1, 20 May 2014"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie kwasu azotowego\nZakres (0,10 – 5,60) mg/m3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014 Srodowisko pracy – powietrze – probki powietrza Stezenie kwasu azotowego\nZakres (0,10 – 5,60) mg/m3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) NIOSH 7907 Method, Issue 1, 20 May 2014","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitric acid concentration","parameters_en":[{"name":"Range","range":"(0,10 – 5,60) mg/m3"}],"search_en":"Workplace environment – air – air samples Nitric acid concentration Ion chromatography with conductometric detection (IC-CD) Range NIOSH 7907 Method, Issue 1, 20 May 2014","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,10 – 5,60) mg/m3"}],"search_zh":"工作场所环境 — 空气 — 空气样品 离子色谱-电导检测法（IC-CD） 范围 NIOSH 7907 Method, Issue 1, 20 May 2014","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20626","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość kwasu siarkowego","parameters":[{"name":"frakcja torakalna"},{"name":"Zakres","range":"(0,0046 – 0,15) mg/m3"},{"name":"Zakres","range":"(0,0033 – 0,050) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu siarkowego\nZakres:\nfrakcja torakalna\nZakres (0,0046 – 0,15) mg/m3\nZakres (0,0033 – 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 1 (71), s. 97-103 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5 -19","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 1 (71), s. 97-103 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5 -19"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość kwasu siarkowego\nZakres:\nfrakcja torakalna\nZakres (0,0046 – 0,15) mg/m3\nZakres (0,0033 – 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 1 (71), s. 97-103 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5 -19 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc kwasu siarkowego\nZakres:\nfrakcja torakalna\nZakres (0,0046 – 0,15) mg/m3\nZakres (0,0033 – 0,050) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 1 (71), s. 97-103 Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 5 -19","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulphuric acid","parameters_en":[{"name":"thoracic fraction"},{"name":"Range","range":"(0,0046 – 0,15) mg/m3"},{"name":"Range","range":"(0,0033 – 0,050) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of sulphuric acid Ion chromatography with conductometric detection (IC-CD) thoracic fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, nr 1 (71), s. 97-103 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5 -19","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"胸腔组分"},{"name":"范围","range":"(0,0046 – 0,15) mg/m3"},{"name":"范围","range":"(0,0033 – 0,050) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 离子色谱-电导检测法（IC-CD） 胸腔组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, nr 1 (71), s. 97-103 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 5 -19","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b20627","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość tlenku azotu","parameters":[{"name":"Zakres","range":"(0,03 – 5,0) mg/m3"},{"name":"Zakres","range":"(0,024 – 4,01) ppm"},{"name":"Zakres","range":"(0,00030 – 0,050) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość tlenku azotu\nZakres:\nZakres (0,03 – 5,0) mg/m3\nZakres (0,024 – 4,01) ppm\nZakres (0,00030 – 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"OSHA Method190","norm_bases":["OSHA Method190"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość tlenku azotu\nZakres:\nZakres (0,03 – 5,0) mg/m3\nZakres (0,024 – 4,01) ppm\nZakres (0,00030 – 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) OSHA Method190 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc tlenku azotu\nZakres:\nZakres (0,03 – 5,0) mg/m3\nZakres (0,024 – 4,01) ppm\nZakres (0,00030 – 0,050) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) OSHA Method190","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen oxide concentration / content","parameters_en":[{"name":"Range","range":"(0,03 – 5,0) mg/m3"},{"name":"Range","range":"(0,024 – 4,01) ppm"},{"name":"Range","range":"(0,00030 – 0,050) mg w próbce"}],"search_en":"Workplace environment – air – air samples Nitrogen oxide concentration / content Ion chromatography with conductometric detection (IC-CD) Range Range Range OSHA Method190","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,03 – 5,0) mg/m3"},{"name":"范围","range":"(0,024 – 4,01) ppm"},{"name":"范围","range":"(0,00030 – 0,050) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 一氧化氮的浓度/含量 离子色谱-电导检测法（IC-CD） 范围 范围 范围 OSHA Method190","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"一氧化氮的浓度/含量"},{"_id":"6a83afc0af14b9c0e7b20628","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość ditlenku azotu","parameters":[{"name":"Zakres","range":"(0,046 – 5) mg/m3"},{"name":"Zakres","range":"(0,024 – 2,61) ppm"},{"name":"Zakres","range":"(0,00046 – 0,050) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość ditlenku azotu\nZakres:\nZakres (0,046 – 5) mg/m3\nZakres (0,024 – 2,61) ppm\nZakres (0,00046 – 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"OSHA Method182","norm_bases":["OSHA Method182"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość ditlenku azotu\nZakres:\nZakres (0,046 – 5) mg/m3\nZakres (0,024 – 2,61) ppm\nZakres (0,00046 – 0,050) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) OSHA Method182 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc ditlenku azotu\nZakres:\nZakres (0,046 – 5) mg/m3\nZakres (0,024 – 2,61) ppm\nZakres (0,00046 – 0,050) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) OSHA Method182","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide concentration / content","parameters_en":[{"name":"Range","range":"(0,046 – 5) mg/m3"},{"name":"Range","range":"(0,024 – 2,61) ppm"},{"name":"Range","range":"(0,00046 – 0,050) mg w próbce"}],"search_en":"Workplace environment – air – air samples Nitrogen dioxide concentration / content Ion chromatography with conductometric detection (IC-CD) Range Range Range OSHA Method182","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,046 – 5) mg/m3"},{"name":"范围","range":"(0,024 – 2,61) ppm"},{"name":"范围","range":"(0,00046 – 0,050) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 二氧化氮的浓度/含量 离子色谱-电导检测法（IC-CD） 范围 范围 范围 OSHA Method182","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"二氧化氮的浓度/含量"},{"_id":"6a83afc0af14b9c0e7b20629","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość kwasu fosforowego","parameters":[{"name":"Zakres","range":"(0,0014 – 5,37) mg/m3"},{"name":"Zakres","range":"(0,0010 – 3,87) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość kwasu fosforowego\nZakres:\nZakres (0,0014 – 5,37) mg/m3\nZakres (0,0010 – 3,87) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"NIOSH 7908 Method Issue 2, 16 November 2023","norm_bases":["NIOSH 7908 Method Issue 2, 16 November 2023"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość kwasu fosforowego\nZakres:\nZakres (0,0014 – 5,37) mg/m3\nZakres (0,0010 – 3,87) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) NIOSH 7908 Method Issue 2, 16 November 2023 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc kwasu fosforowego\nZakres:\nZakres (0,0014 – 5,37) mg/m3\nZakres (0,0010 – 3,87) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) NIOSH 7908 Method Issue 2, 16 November 2023","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of phosphoric acid","parameters_en":[{"name":"Range","range":"(0,0014 – 5,37) mg/m3"},{"name":"Range","range":"(0,0010 – 3,87) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of phosphoric acid Ion chromatography with conductometric detection (IC-CD) Range Range NIOSH 7908 Method Issue 2, 16 November 2023","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0014 – 5,37) mg/m3"},{"name":"范围","range":"(0,0010 – 3,87) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 离子色谱-电导检测法（IC-CD） 范围 范围 NIOSH 7908 Method Issue 2, 16 November 2023","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品"},{"_id":"6a83afc0af14b9c0e7b2062a","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość ditlenku siarki","parameters":[{"name":"Zakres","range":"(0,110 – 4,40) mg/m3"},{"name":"Zakres","range":"(0,041 – 1,66) ppm"},{"name":"Zakres","range":"(0,020 – 0,792) mg w próbce"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie / zawartość ditlenku siarki\nZakres:\nZakres (0,110 – 4,40) mg/m3\nZakres (0,041 – 1,66) ppm\nZakres (0,020 – 0,792) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2025, nr 4 (126), s. 133-146","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2025, nr 4 (126), s. 133-146"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość ditlenku siarki\nZakres:\nZakres (0,110 – 4,40) mg/m3\nZakres (0,041 – 1,66) ppm\nZakres (0,020 – 0,792) mg w próbce\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Podstawy i Metody Oceny Środowiska Pracy 2025, nr 4 (126), s. 133-146 Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc ditlenku siarki\nZakres:\nZakres (0,110 – 4,40) mg/m3\nZakres (0,041 – 1,66) ppm\nZakres (0,020 – 0,792) mg w probce\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Podstawy i Metody Oceny Srodowiska Pracy 2025, nr 4 (126), s. 133-146","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulphur dioxide","parameters_en":[{"name":"Range","range":"(0,110 – 4,40) mg/m3"},{"name":"Range","range":"(0,041 – 1,66) ppm"},{"name":"Range","range":"(0,020 – 0,792) mg w próbce"}],"search_en":"Workplace environment – air – air samples Concentration / content of sulphur dioxide Ion chromatography with conductometric detection (IC-CD) Range Range Range Podstawy i Metody Oceny Środowiska Pracy 2025, nr 4 (126), s. 133-146","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,110 – 4,40) mg/m3"},{"name":"范围","range":"(0,041 – 1,66) ppm"},{"name":"范围","range":"(0,020 – 0,792) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 二氧化硫的浓度/含量 离子色谱-电导检测法（IC-CD） 范围 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2025, nr 4 (126), s. 133-146","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"二氧化硫的浓度/含量"},{"_id":"6a83afc0af14b9c0e7b2062b","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza","methodology":"Stężenie / zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,0057 – 20) mg/m3"},{"name":"Zakres","range":"(0,0016 – 0,072) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)"],"computed":[],"activity":"Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,0057 – 20) mg/m3\nZakres (0,0016 – 0,072) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV)","reference":"NIOSH 2016, Issue 2:15 March 2003 | PB-06/17 wydanie 1 z dnia 06.03.2025 r.","norm_bases":["NIOSH 2016, Issue 2:15 March 2003","PB-06/17 wydanie 1 z dnia 06.03.2025 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,0057 – 20) mg/m3\nZakres (0,0016 – 0,072) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV) NIOSH 2016, Issue 2:15 March 2003 | PB-06/17 wydanie 1 z dnia 06.03.2025 r. Srodowisko pracy – powietrze – probki powietrza Stezenie / zawartosc formaldehydu\nZakres:\nZakres (0,0057 – 20) mg/m3\nZakres (0,0016 – 0,072) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV) NIOSH 2016, Issue 2:15 March 2003 | PB-06/17 wydanie 1 z dnia 06.03.2025 r.","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration / content","parameters_en":[{"name":"Range","range":"(0,0057 – 20) mg/m3"},{"name":"Range","range":"(0,0016 – 0,072) mg w próbce"}],"search_en":"Workplace environment – air – air samples Formaldehyde concentration / content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV) Range Range NIOSH 2016, Issue 2:15 March 2003 | PB-06/17 wydanie 1 z dnia 06.03.2025 r.","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV)","test_object_en":"Workplace environment – air – air samples","parameters_zh":[{"name":"范围","range":"(0,0057 – 20) mg/m3"},{"name":"范围","range":"(0,0016 – 0,072) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 空气样品 甲醛的浓度/含量 高效液相色谱-分光光度检测法（HPLC-UV） 范围 范围 NIOSH 2016, Issue 2:15 March 2003 | PB-06/17 wydanie 1 z dnia 06.03.2025 r.","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV）","test_object_zh":"工作场所环境 — 空气 — 空气样品","methodology_zh":"甲醛的浓度/含量"},{"_id":"6a83afc0af14b9c0e7b2062c","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry impregnowane","methodology":"Stężenie / zawartość: diizocyjanianu tolueno-2,4-diylu, diizocyjanianu tolueno 2,6-diylu, diizocyjanianu toluenodiylu – mieszanina izomerów 2,4-, 2,6-w przeliczeniu na grupę NCO","parameters":[{"name":"Zakres","range":"(0,0000676 – 0,24) mg/m3"},{"name":"Zakres","range":"(0,0135– 7,24) μg w próbce"},{"name":"Diizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość: diizocyjanianu tolueno-2,4-diylu, diizocyjanianu tolueno 2,6-diylu, diizocyjanianu toluenodiylu – mieszanina izomerów 2,4-, 2,6-w przeliczeniu na grupę NCO\nZakres:\nZakres (0,0000676 – 0,24) mg/m3\nZakres (0,0135– 7,24) μg w próbce\nDiizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04490:2017-10","norm_bases":["PN-Z-04490:2017-10"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry impregnowane Stężenie / zawartość: diizocyjanianu tolueno-2,4-diylu, diizocyjanianu tolueno 2,6-diylu, diizocyjanianu toluenodiylu – mieszanina izomerów 2,4-, 2,6-w przeliczeniu na grupę NCO\nZakres:\nZakres (0,0000676 – 0,24) mg/m3\nZakres (0,0135– 7,24) μg w próbce\nDiizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04490:2017-10 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry impregnowane Stezenie / zawartosc: diizocyjanianu tolueno-2,4-diylu, diizocyjanianu tolueno 2,6-diylu, diizocyjanianu toluenodiylu – mieszanina izomerow 2,4-, 2,6-w przeliczeniu na grupe NCO\nZakres:\nZakres (0,0000676 – 0,24) mg/m3\nZakres (0,0135– 7,24) μg w probce\nDiizocyjaniany – w przeliczeniu na grupe NCO (suma stezen/zawartosci izocyjanianowych grup funkcyjnych zwiazkow diizocyjanianow)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04490:2017-10","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0000676 – 0,24) mg/m3"},{"name":"Range","range":"(0,0135– 7,24) μg w próbce"},{"name":"Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds)"}],"search_en":"Workplace environment – air – air samples collected on impregnated filters High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range Range Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds) PN-Z-04490:2017-10","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on impregnated filters","parameters_zh":[{"name":"范围","range":"(0,0000676 – 0,24) mg/m3"},{"name":"范围","range":"(0,0135– 7,24) μg w próbce"},{"name":"Diizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)"}],"search_zh":"工作环境 － 空气 － 采集在浸渍滤膜上的空气样品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 范围 PN-Z-04490:2017-10","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作环境 － 空气 － 采集在浸渍滤膜上的空气样品"},{"_id":"6a83afc0af14b9c0e7b2062d","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry impregnowane","methodology":"Stężenie / zawartość: diizocyjanianu heksano-1,6-diylu w przeliczeniu na grupę NCO","parameters":[{"name":"Zakres","range":"(0,0002248 – 0,25) mg/m3"},{"name":"Zakres","range":"(0,0450 – 7,49) μg w próbce"},{"name":"Diizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość: diizocyjanianu heksano-1,6-diylu w przeliczeniu na grupę NCO\nZakres:\nZakres (0,0002248 – 0,25) mg/m3\nZakres (0,0450 – 7,49) μg w próbce\nDiizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"OSHA Method 5002","norm_bases":["OSHA Method 5002"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry impregnowane Stężenie / zawartość: diizocyjanianu heksano-1,6-diylu w przeliczeniu na grupę NCO\nZakres:\nZakres (0,0002248 – 0,25) mg/m3\nZakres (0,0450 – 7,49) μg w próbce\nDiizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) OSHA Method 5002 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry impregnowane Stezenie / zawartosc: diizocyjanianu heksano-1,6-diylu w przeliczeniu na grupe NCO\nZakres:\nZakres (0,0002248 – 0,25) mg/m3\nZakres (0,0450 – 7,49) μg w probce\nDiizocyjaniany – w przeliczeniu na grupe NCO (suma stezen/zawartosci izocyjanianowych grup funkcyjnych zwiazkow diizocyjanianow)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) OSHA Method 5002","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,0002248 – 0,25) mg/m3"},{"name":"Range","range":"(0,0450 – 7,49) μg w próbce"},{"name":"Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds)"}],"search_en":"Workplace environment – air – air samples collected on impregnated filters High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range Range Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds) OSHA Method 5002","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on impregnated filters","parameters_zh":[{"name":"范围","range":"(0,0002248 – 0,25) mg/m3"},{"name":"范围","range":"(0,0450 – 7,49) μg w próbce"},{"name":"Diizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)"}],"search_zh":"工作环境 － 空气 － 采集在浸渍滤膜上的空气样品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 范围 OSHA Method 5002","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作环境 － 空气 － 采集在浸渍滤膜上的空气样品"},{"_id":"6a83afc0af14b9c0e7b2062e","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry impregnowane","methodology":"Stężenie / zawartość: 4,4’ metylenobis (fenyloizocyjanianu) w przeliczeniu na grupę NCO","parameters":[{"name":":","range":"(0,000151 – 0,17) mg/m3"},{"name":":","range":"(0,0302 – 5,037) μg w próbce"},{"name":"Diizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość: 4,4’ metylenobis (fenyloizocyjanianu) w przeliczeniu na grupę NCO\nZakres:\n: (0,000151 – 0,17) mg/m3\n: (0,0302 – 5,037) μg w próbce\nDiizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"OSHA Method 5002","norm_bases":["OSHA Method 5002"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry impregnowane Stężenie / zawartość: 4,4’ metylenobis (fenyloizocyjanianu) w przeliczeniu na grupę NCO\nZakres:\n: (0,000151 – 0,17) mg/m3\n: (0,0302 – 5,037) μg w próbce\nDiizocyjaniany – w przeliczeniu na grupę NCO (suma stężeń/zawartości izocyjanianowych grup funkcyjnych związkow diizocyjanianów)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) OSHA Method 5002 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry impregnowane Stezenie / zawartosc: 4,4’ metylenobis (fenyloizocyjanianu) w przeliczeniu na grupe NCO\nZakres:\n: (0,000151 – 0,17) mg/m3\n: (0,0302 – 5,037) μg w probce\nDiizocyjaniany – w przeliczeniu na grupe NCO (suma stezen/zawartosci izocyjanianowych grup funkcyjnych zwiazkow diizocyjanianow)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) OSHA Method 5002","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":":","range":"(0,000151 – 0,17) mg/m3"},{"name":":","range":"(0,0302 – 5,037) μg w próbce"},{"name":"Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds)"}],"search_en":"Workplace environment – air – air samples collected on impregnated filters High-performance liquid chromatography with fluorescence detection (HPLC-FLD) : : Diisocyanates – expressed as NCO group (sum of concentrations/contents of isocyanate functional groups of diisocyanate compounds) OSHA Method 5002","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on impregnated filters","search_zh":"工作环境 － 空气 － 采集在浸渍滤膜上的空气样品 高效液相色谱-荧光检测法（HPLC-FLD） OSHA Method 5002","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作环境 － 空气 － 采集在浸渍滤膜上的空气样品"},{"_id":"6a83afc0af14b9c0e7b2062f","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 - 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(35 - 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 - 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (35 - 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 - 135) dB\nSzczytowy poziom dzwieku C\nZakres (35 - 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25 - 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(35 - 140) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25 - 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(35 - 140) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83afc0af14b9c0e7b20630","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czas pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czas pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czas pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czas pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8-godz. dobowego wymiaru czas pracy"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83afc0af14b9c0e7b20631","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach oktawowych o częstotliwościach środkowych od 16 Hz do 16000 Hz","parameters":[{"name":"Zakres","range":"(35 - 140) dB"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach oktawowych o częstotliwościach środkowych od 16 Hz do 16000 Hz\nZakres (35 - 140) dB","reference":"PB-06/03wydanie 1 z dnia 02.01.2020 r.","norm_bases":["PB-06/03wydanie 1 z dnia 02.01.2020 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom ciśnienia akustycznego w pasmach oktawowych o częstotliwościach środkowych od 16 Hz do 16000 Hz\nZakres (35 - 140) dB PB-06/03wydanie 1 z dnia 02.01.2020 r. Srodowisko pracy – halas Rownowazny poziom cisnienia akustycznego w pasmach oktawowych o czestotliwosciach srodkowych od 16 Hz do 16000 Hz\nZakres (35 - 140) dB PB-06/03wydanie 1 z dnia 02.01.2020 r.","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure level in octave bands with centre frequencies from 16 Hz to 16000 Hz","parameters_en":[{"name":"Range","range":"(35 - 140) dB"}],"search_en":"Workplace environment – noise Equivalent sound pressure level in octave bands with centre frequencies from 16 Hz to 16000 Hz Range PB-06/03wydanie 1 z dnia 02.01.2020 r.","test_object_en":"Workplace environment – noise","parameters_zh":[{"name":"范围","range":"(35 - 140) dB"}],"search_zh":"工作场所环境 — 噪声 范围 PB-06/03wydanie 1 z dnia 02.01.2020 r.","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83afc0af14b9c0e7b20632","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Zakres","range":"(60 - 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (60 - 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (60 - 140) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (60 - 140) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Range","range":"(60 - 140) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure levels in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"范围","range":"(60 - 140) dB"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a83afc0af14b9c0e7b20633","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件： 每日 8 小时工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件："},{"_id":"6a83afc0af14b9c0e7b20634","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,1 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,1 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy – drgania przenoszone na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,1 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,1 – 100) m/s2"}],"search_en":"Workplace environment – hand-arm vibration transmitted to the human body Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration transmitted to the human body","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,1 – 100) m/s2"}],"search_zh":"工作环境 － 经上肢传递至人体的振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作环境 － 经上肢传递至人体的振动"},{"_id":"6a83afc0af14b9c0e7b20635","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych,skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych,skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004+A1:2015-11"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania przenoszone na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych,skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11 Srodowisko pracy – drgania przenoszone na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych,skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","categories":["environment"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration transmitted to the human body Daily exposure, expressed as the energy-equivalent value for an 8-hour working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration transmitted to the human body","search_zh":"工作环境 － 经上肢传递至人体的振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11","test_object_zh":"工作环境 － 经上肢传递至人体的振动"},{"_id":"6a83afc0af14b9c0e7b20636","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01 – 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 – 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,01 – 50) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 – 50) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a83afc0af14b9c0e7b20637","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a83afc0af14b9c0e7b20638","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(5 – 60) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20,0 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 – 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 60) °C\nWilgotność powietrza\nZakres (20,0 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 – 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 60) °C\nWilgotność powietrza\nZakres (20,0 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5 – 50) °C\nTemperatura poczernionej kuli\nZakres (5 – 60) °C\nWilgotnosc powietrza\nZakres (20,0 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(5 – 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(5 – 60) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20,0 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(5 – 60) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20,0 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83afc0af14b9c0e7b20639","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83afc0af14b9c0e7b2063a","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(5 – 45) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 60) °C"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (5 – 45) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (5 – 45) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (5 – 45) °C\nTemperatura poczernionej kuli\nZakres (10 – 60) °C\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(5 – 45) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 60) °C"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range Air velocity Range PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(5 – 45) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 60) °C"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 空气流速 范围 PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83afc0af14b9c0e7b2063b","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83afc0af14b9c0e7b2063c","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-20 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-20 – 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli\nZakres (-20 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO11079:2008+Ap1:2013-10","norm_bases":["PN-EN ISO11079:2008+Ap1:2013-10"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli\nZakres (-20 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO11079:2008+Ap1:2013-10 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-20 – 10) °C\nTemperatura poczernionej kuli\nZakres (-20 – 10) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO11079:2008+Ap1:2013-10","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-20 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-20 – 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO11079:2008+Ap1:2013-10","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-20 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-20 – 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO11079:2008+Ap1:2013-10","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83afc0af14b9c0e7b2063d","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO11079:2008+Ap1:2013-10","norm_bases":["PN-EN ISO11079:2008+Ap1:2013-10"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO11079:2008+Ap1:2013-10 Srodowisko pracy – mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO11079:2008+Ap1:2013-10","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO11079:2008+Ap1:2013-10","test_object_en":"Workplace environment – cold microclimate","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO11079:2008+Ap1:2013-10","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a83afc0af14b9c0e7b2063e","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PB-06/01 wydanie 2 z dnia 01.02.2024 r.","norm_bases":["PB-06/01 wydanie 2 z dnia 01.02.2024 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia PB-06/01 wydanie 2 z dnia 01.02.2024 r. Srodowisko pracy – oswietlenie elektryczne Natezenie oswietlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezposrednia PB-06/01 wydanie 2 z dnia 01.02.2024 r.","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5000) lx"}],"search_en":"Workplace environment – electric lighting Illuminance Direct measurement method Range PB-06/01 wydanie 2 z dnia 01.02.2024 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5000) lx"}],"search_zh":"工作环境 － 电气照明 照度 直接测量法 范围 PB-06/01 wydanie 2 z dnia 01.02.2024 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a83afc0af14b9c0e7b2063f","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PB-06/01 wydanie 2 z dnia 01.02.2024 r.","norm_bases":["PB-06/01 wydanie 2 z dnia 01.02.2024 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne Równomierność oświetlenia (z obliczeń) PB-06/01 wydanie 2 z dnia 01.02.2024 r. Srodowisko pracy – oswietlenie elektryczne Rownomiernosc oswietlenia (z obliczen) PB-06/01 wydanie 2 z dnia 01.02.2024 r.","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – electric lighting Illuminance uniformity (calculated) PB-06/01 wydanie 2 z dnia 01.02.2024 r.","test_object_en":"Workplace environment – electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 电气照明 照度均匀度（计算值） PB-06/01 wydanie 2 z dnia 01.02.2024 r.","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a83afc0af14b9c0e7b20640","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne","methodology":"Luminancja","parameters":[{"name":"Zakres","range":"(25 – 400) cd/m2"}],"technique":null,"techniques":[],"computed":[],"activity":"Luminancja\nZakres (25 – 400) cd/m2","reference":"PB-06/01 wydanie 2 z dnia 01.02.2024 r.","norm_bases":["PB-06/01 wydanie 2 z dnia 01.02.2024 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne Luminancja\nZakres (25 – 400) cd/m2 PB-06/01 wydanie 2 z dnia 01.02.2024 r. Srodowisko pracy – oswietlenie elektryczne Luminancja\nZakres (25 – 400) cd/m2 PB-06/01 wydanie 2 z dnia 01.02.2024 r.","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Luminance","parameters_en":[{"name":"Range","range":"(25 – 400) cd/m2"}],"search_en":"Workplace environment – electric lighting Luminance Range PB-06/01 wydanie 2 z dnia 01.02.2024 r.","test_object_en":"Workplace environment – electric lighting","parameters_zh":[{"name":"范围","range":"(25 – 400) cd/m2"}],"search_zh":"工作环境 － 电气照明 亮度 范围 PB-06/01 wydanie 2 z dnia 01.02.2024 r.","test_object_zh":"工作环境 － 电气照明","methodology_zh":"亮度"},{"_id":"6a83afc0af14b9c0e7b20641","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne","methodology":"Współczynniki odbicia na podstawowych powierzchniach wnętrza (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Współczynniki odbicia na podstawowych powierzchniach wnętrza (z obliczeń)","reference":"PB-06/01 wydanie 2 z dnia 01.02.2024 r.","norm_bases":["PB-06/01 wydanie 2 z dnia 01.02.2024 r."],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne Współczynniki odbicia na podstawowych powierzchniach wnętrza (z obliczeń) PB-06/01 wydanie 2 z dnia 01.02.2024 r. Srodowisko pracy – oswietlenie elektryczne Wspolczynniki odbicia na podstawowych powierzchniach wnetrza (z obliczen) PB-06/01 wydanie 2 z dnia 01.02.2024 r.","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reflection coefficients on the main interior surfaces (calculated)","search_en":"Workplace environment – electric lighting Reflection coefficients on the main interior surfaces (calculated) PB-06/01 wydanie 2 z dnia 01.02.2024 r.","test_object_en":"Workplace environment – electric lighting","search_zh":"工作环境 － 电气照明 PB-06/01 wydanie 2 z dnia 01.02.2024 r.","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a83afc0af14b9c0e7b20642","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm","parameters":[{"name":"Zakres","range":"(3,0*10 -6 – 25,0) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda A)","techniques":["Metoda pomiarowa bezpośrednia (metoda A)"],"computed":[],"activity":"Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm\nZakres (3,0*10 -6 – 25,0) W/m2\nMetoda pomiarowa bezpośrednia (metoda A)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm\nZakres (3,0*10 -6 – 25,0) W/m2\nMetoda pomiarowa bezpośrednia (metoda A) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia UVA, UVB i UVC w zakresie spektralnym (180 – 400) nm\nZakres (3,0*10 -6 – 25,0) W/m2\nMetoda pomiarowa bezposrednia (metoda A) PN-EN 14255-1:2010","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance of UVA, UVB and UVC in the spectral range (180 – 400) nm","parameters_en":[{"name":"Range","range":"(3,0*10 -6 – 25,0) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Effective irradiance of UVA, UVB and UVC in the spectral range (180 – 400) nm Direct measurement method (method A) Range PN-EN 14255-1:2010","technique_en":"Direct measurement method (method A)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(3,0*10 -6 – 25,0) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 A） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 A）"},{"_id":"6a83afc0af14b9c0e7b20643","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm (z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm (z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne napromienienie nadfioletem niebezpiecznym w zakresie spektralnym (180 – 400) nm (z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiant exposure to hazardous ultraviolet in the spectral range (180 – 400) nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Effective radiant exposure to hazardous ultraviolet in the spectral range (180 – 400) nm (calculated) PN-EN 14255-1:2010","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83afc0af14b9c0e7b20644","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm","parameters":[{"name":"Zakres","range":"(2,00-6 – 1000) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda M)","techniques":["Metoda pomiarowa bezpośrednia (metoda M)"],"computed":[],"activity":"Natężenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm\nZakres (2,00-6 – 1000) W/m2\nMetoda pomiarowa bezpośrednia (metoda M)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm\nZakres (2,00-6 – 1000) W/m2\nMetoda pomiarowa bezpośrednia (metoda M) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia promieniowania UVA w zakresie spektralnym (315 – 400) nm\nZakres (2,00-6 – 1000) W/m2\nMetoda pomiarowa bezposrednia (metoda M) PN-EN 14255-1:2010","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance of UVA radiation in the spectral range (315 – 400) nm","parameters_en":[{"name":"Range","range":"(2,00-6 – 1000) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Irradiance of UVA radiation in the spectral range (315 – 400) nm Direct measurement method (method M) Range PN-EN 14255-1:2010","technique_en":"Direct measurement method (method M)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(2,00-6 – 1000) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 M） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 M）"},{"_id":"6a83afc0af14b9c0e7b20645","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm (z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm (z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie promieniowaniem UVA w zakresie spektralnym (315 – 400) nm (z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure to UVA radiation in the spectral range (315 – 400) nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Radiant exposure to UVA radiation in the spectral range (315 – 400) nm (calculated) PN-EN 14255-1:2010","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83afc0af14b9c0e7b20646","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (305 – 700) nm","parameters":[{"name":"Zakres","range":"(7,69*10-7– 1540) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda O)","techniques":["Metoda pomiarowa bezpośrednia (metoda O)"],"computed":[],"activity":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (305 – 700) nm\nZakres (7,69*10-7– 1540) W/m2\nMetoda pomiarowa bezpośrednia (metoda O)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia VIS w zakresie spektralnym (305 – 700) nm\nZakres (7,69*10-7– 1540) W/m2\nMetoda pomiarowa bezpośrednia (metoda O) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia VIS w zakresie spektralnym (305 – 700) nm\nZakres (7,69*10-7– 1540) W/m2\nMetoda pomiarowa bezposrednia (metoda O) PN-EN 14255-2:2010","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance VIS in the spectral range (305 – 700) nm","parameters_en":[{"name":"Range","range":"(7,69*10-7– 1540) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Effective irradiance VIS in the spectral range (305 – 700) nm Direct measurement method (method O) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method O)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(7,69*10-7– 1540) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 O） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 O）"},{"_id":"6a83afc0af14b9c0e7b20647","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (305 – 700) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (305 – 700) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (305 – 700) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna promieniowania VIS w zakresie spektralnym (305 – 700) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance of VIS radiation in the spectral range (305 – 700) nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Effective radiance of VIS radiation in the spectral range (305 – 700) nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83afc0af14b9c0e7b20648","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm","parameters":[{"name":"Zakres","range":"(0,9 – 4000) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda R)","techniques":["Metoda pomiarowa bezpośrednia (metoda R)"],"computed":[],"activity":"Natężenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm\nZakres (0,9 – 4000) W/m2\nMetoda pomiarowa bezpośrednia (metoda R)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm\nZakres (0,9 – 4000) W/m2\nMetoda pomiarowa bezpośrednia (metoda R) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia IRA i IRB w zakresie spektralnym (780 – 3000) nm\nZakres (0,9 – 4000) W/m2\nMetoda pomiarowa bezposrednia (metoda R) PN-EN 14255-2:2010","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance of IRA and IRB in the spectral range (780 – 3000) nm","parameters_en":[{"name":"Range","range":"(0,9 – 4000) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Irradiance of IRA and IRB in the spectral range (780 – 3000) nm Direct measurement method (method R) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method R)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(0,9 – 4000) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 R） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 R）"},{"_id":"6a83afc0af14b9c0e7b20649","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie w zakresie spektralnym (780 – 3000) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie w zakresie spektralnym (780 – 3000) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie w zakresie spektralnym (780 – 3000) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie w zakresie spektralnym (780 – 3000) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure in the spectral range (780 – 3000) nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Radiant exposure in the spectral range (780 – 3000) nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83afc0af14b9c0e7b2064a","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm","parameters":[{"name":"Zakres","range":"(4,0*10-7 – 300) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm\nZakres (4,0*10-7 – 300) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","norm_bases":["PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm\nZakres (4,0*10-7 – 300) W/m2\nMetoda pomiarowa bezpośrednia PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia IRA w zakresie spektralnym (780 – 1400) nm\nZakres (4,0*10-7 – 300) W/m2\nMetoda pomiarowa bezposrednia PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance of IRA in the spectral range (780 – 1400) nm","parameters_en":[{"name":"Range","range":"(4,0*10-7 – 300) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Effective irradiance of IRA in the spectral range (780 – 1400) nm Direct measurement method Range PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","technique_en":"Direct measurement method","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(4,0*10-7 – 300) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法 范围 PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83afc0af14b9c0e7b2064b","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna IRA w zakresie spektralnym (770 –1400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna IRA w zakresie spektralnym (770 –1400) nm (z obliczeń)","reference":"PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","norm_bases":["PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna IRA w zakresie spektralnym (770 –1400) nm (z obliczeń) PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna IRA w zakresie spektralnym (770 –1400) nm (z obliczen) PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance IRA in the spectral range (770 –1400) nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Effective radiance IRA in the spectral range (770 –1400) nm (calculated) PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-T-05687:2002 pkt. 2.5.4 i pkt. 2.5.5","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83afc0af14b9c0e7b2064c","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 110) dB"},{"name":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres:\nZakres (25 – 110) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres:\nZakres (25 – 110) dB\nRównoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres:\nZakres (25 – 110) dB\nRownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen)\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 110) dB"},{"name":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 110) dB"},{"name":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a83afc0af14b9c0e7b2064d","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa","reference":"PN ISO 9613-2:2002","norm_bases":["PN ISO 9613-2:2002"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN\nMetoda obliczeniowa PN ISO 9613-2:2002 Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN\nMetoda obliczeniowa PN ISO 9613-2:2002","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN","search_en":"General environment – noise from installations, equipment and industrial plants Equivalent A-weighted sound level for the reference time T expressed by the indicators LAeqD and LAeqN Calculation method PN ISO 9613-2:2002","technique_en":"Calculation method","test_object_en":"General environment – noise from installations, equipment and industrial plants","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级 计算法 PN ISO 9613-2:2002","technique_zh":"计算法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"以 LAeqD 与 LAeqN 指标表示的参考时段 T 内的 A 计权等效声级"},{"_id":"6a83afc0af14b9c0e7b2064e","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Maszyny i urządzenia - hałas","methodology":"Poziom ciśnienia akustycznego","parameters":[{"name":"skorygowany charakterystyką"},{"name":"częstotliwościową A"},{"name":"Zakres","range":"(25 – 110) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (25 – 110) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia - hałas Poziom ciśnienia akustycznego\nZakres:\nskorygowany charakterystyką\nczęstotliwościową A\nZakres (25 – 110) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia - halas Poziom cisnienia akustycznego\nZakres:\nskorygowany charakterystyka\nczestotliwosciowa A\nZakres (25 – 110) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound pressure level","parameters_en":[{"name":"weighted with the characteristic"},{"name":"frequency weighting A"},{"name":"Range","range":"(25 – 110) dB"}],"search_en":"Machinery and equipment - noise Sound pressure level Direct measurement method weighted with the characteristic frequency weighting A Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment - noise","parameters_zh":[{"name":"按特性计权"},{"name":"A 计权"},{"name":"范围","range":"(25 – 110) dB"}],"search_zh":"机器与设备 — 噪声 声压级 直接测量法 按特性计权 A 计权 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","methodology_zh":"声压级","test_object_zh":"机器与设备 — 噪声"},{"_id":"6a83afc0af14b9c0e7b2064f","lab_id":"69ad52a3de79e566650fb40a","country":"PL","accr_number":"AB 802","accr_body":"PCA","test_object":"Maszyny i urządzenia - hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Pracownia Badań Środowiska Pracy „Higiena Pracy” Marek Smoczyński","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia - hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia - halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment - noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_en":"Machinery and equipment - noise","methodology_zh":"声功率级（计算值）","search_zh":"机器与设备 — 噪声 声功率级（计算值） PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 — 噪声"}],"has_pdf":true}