{"lab":{"_id":"69ad52a3de79e566650fb400","accr_number":"AB 795","country":"PL","accr_body":"PCA","address":"ul. Nowy Świat 2a, 62-800 Kalisz, LABORATORIUM, ul. Nad Prosną 28-34, 62-800 Kalisz","categories":["water","microbiology"],"city":"Kalisz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":44,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_795.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. ul. nowy świat 2a, 62-800 kalisz, laboratorium, ul. nad prosną 28-34, 62-800 kalisz other water pharma materials electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:40.935Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:40.935Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20795,podmiot.html","fields_of_testing":[{"codes":"C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków, wody do spożycia przez ludzi","en":"Chemical tests and sampling of sewage, drinking water."},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"K/29/P, K/28/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water."},{"codes":"N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków, wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of sewage, drinking water."},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"23","date":"03.12.2024"},"parse_date":"2026-07-20T07:09:50.765Z","parse_source":"script-pdfplumber","map_coord":[51.75767,18.084293],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":44,"microbiology":5,"materials":1},"category_scores":{"water":38.72,"microbiology":0.5,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825eb84","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura ścieków/pobranej próbki ścieków"},{"name":"Zakres","range":"(5,0 - 35) oC"}],"parameters_en":[{"name":"Temperature of wastewater/collected wastewater sample"},{"name":"Range","range":"(5,0 - 35) oC"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (5,0 - 35) oC\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (5,0 - 35) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow/pobranej probki sciekow\nZakres (5,0 - 35) oC\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater/collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(5,0 - 35) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9bef1c10c8ce825eb85","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(10 - 1500) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 1500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (10 - 1500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (10 - 1500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (10 - 1500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(10 - 1500) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825eb86","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie potasu","methodology_en":"Potassium concentration","parameters":[{"name":"Zakres","range":"(0,10 - 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 200) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie potasu\nZakres (0,10 - 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-2:1994+AK:1997","norm_bases":["PN-ISO 9964-2:1994+AK:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie potasu\nZakres (0,10 - 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994+AK:1997 Scieki Stezenie potasu\nZakres (0,10 - 200) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994+AK:1997","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Potassium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-2:1994+AK:1997","parameters_zh":[{"name":"范围","range":"(0,10 - 200) mg/l"}],"search_zh":"污水 钾浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-2:1994+AK:1997","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"钾浓度"},{"_id":"6a5dc9bef1c10c8ce825eb87","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(1,0 - 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 - 300) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (1,0 - 300) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+AK:1997 +Ap1:2009","norm_bases":["PN-ISO 9964-1:1994+AK:1997 +Ap1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie sodu\nZakres (1,0 - 300) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+AK:1997 +Ap1:2009 Scieki Stezenie sodu\nZakres (1,0 - 300) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+AK:1997 +Ap1:2009","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+AK:1997 +Ap1:2009","parameters_zh":[{"name":"范围","range":"(1,0 - 300) mg/l"}],"search_zh":"污水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+AK:1997 +Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"钠浓度"},{"_id":"6a5dc9bef1c10c8ce825eb88","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(3 - 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 - 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki, Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 - 6000) mg/l O2"}],"search_zh":"废水、水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","methodology_zh":"五日生化需氧量（BOD5）","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb89","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,10 - 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 - 50) mg/l\nMetoda spektrofotometryczna","reference":"Metodyka firmy HACH-LANGE LCK 349, wydanie 4 z 11/2020","norm_bases":["Metodyka firmy HACH-LANGE LCK 349, wydanie 4 z 11/2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie fosforu ogólnego\nZakres (0,10 - 50) mg/l\nMetoda spektrofotometryczna Metodyka firmy HACH-LANGE LCK 349, wydanie 4 z 11/2020 Scieki, Woda Stezenie fosforu ogolnego\nZakres (0,10 - 50) mg/l\nMetoda spektrofotometryczna Metodyka firmy HACH-LANGE LCK 349, wydanie 4 z 11/2020","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total phosphorus concentration Spectrophotometric method Range Metodyka firmy HACH-LANGE LCK 349, wydanie 4 z 11/2020","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 50) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 范围 Metodyka firmy HACH-LANGE LCK 349, wydanie 4 z 11/2020","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb8a","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Indeks Chemicznego Zapotrzebowania Tlenu (ChZT-Cr)","methodology_en":"Chemical Oxygen Demand index (COD-Cr)","parameters":[{"name":"Zakres","range":"(20 - 10000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(20 - 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks Chemicznego Zapotrzebowania Tlenu (ChZT-Cr)\nZakres (20 - 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Indeks Chemicznego Zapotrzebowania Tlenu (ChZT-Cr)\nZakres (20 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Woda Indeks Chemicznego Zapotrzebowania Tlenu (ChZT-Cr)\nZakres (20 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Chemical Oxygen Demand index (COD-Cr) Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(20 - 10000) mg/l O2"}],"search_zh":"废水、水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb8b","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie chromu ogólnego","methodology_en":"Total chromium concentration","parameters":[{"name":"Zakres","range":"(0,10 - 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 20) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie chromu ogólnego\nZakres (0,10 - 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000","norm_bases":["PN-EN 1233:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie chromu ogólnego\nZakres (0,10 - 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 Scieki, Woda Stezenie chromu ogolnego\nZakres (0,10 - 20) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total chromium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN 1233:2000","parameters_zh":[{"name":"范围","range":"(0,10 - 20) mg/l"}],"search_zh":"废水、水 总铬浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN 1233:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水","methodology_zh":"总铬浓度"},{"_id":"6a5dc9bef1c10c8ce825eb8c","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie metali:","methodology_en":"Metal concentrations:","parameters":[{"name":"Cu","range":"(0,10 - 20) mg/l"},{"name":"Zn","range":"(0,10 - 10) mg/l"},{"name":"Cd","range":"(0,10 - 20) mg/l"},{"name":"Ni","range":"(0,10 - 10) mg/l"},{"name":"Pb","range":"(0,25 - 10) mg/l"}],"parameters_en":[{"name":"Cu","range":"(0,10 - 20) mg/l"},{"name":"Zn","range":"(0,10 - 10) mg/l"},{"name":"Cd","range":"(0,10 - 20) mg/l"},{"name":"Ni","range":"(0,10 - 10) mg/l"},{"name":"Pb","range":"(0,25 - 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali:\nZakres:\nCu (0,10 - 20) mg/l\nZn (0,10 - 10) mg/l\nCd (0,10 - 20) mg/l\nNi (0,10 - 10) mg/l\nPb (0,25 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie metali:\nZakres:\nCu (0,10 - 20) mg/l\nZn (0,10 - 10) mg/l\nCd (0,10 - 20) mg/l\nNi (0,10 - 10) mg/l\nPb (0,25 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Scieki, Woda Stezenie metali:\nZakres:\nCu (0,10 - 20) mg/l\nZn (0,10 - 10) mg/l\nCd (0,10 - 20) mg/l\nNi (0,10 - 10) mg/l\nPb (0,25 - 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["water","materials"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Metal concentrations: Flame atomic absorption spectrometry (FAAS) Cu Zn Cd Ni Pb PN-ISO 8288:2002","parameters_zh":[{"name":"Cu","range":"(0,10 - 20) mg/l"},{"name":"Zn","range":"(0,10 - 10) mg/l"},{"name":"Cd","range":"(0,10 - 20) mg/l"},{"name":"Ni","range":"(0,10 - 10) mg/l"},{"name":"Pb","range":"(0,25 - 10) mg/l"}],"search_zh":"废水、水 金属浓度： 火焰原子吸收光谱法（FAAS） Cu Zn Cd Ni Pb PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水","methodology_zh":"金属浓度："},{"_id":"6a5dc9bef1c10c8ce825eb8d","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,10 - 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,10 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie żelaza ogólnego\nZakres (0,10 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Scieki, Woda Stezenie zelaza ogolnego\nZakres (0,10 - 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total iron concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 10) mg/l"}],"search_zh":"废水、水 总铁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb8e","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,10 - 5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 5) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,10 - 5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie manganu\nZakres (0,10 - 5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Scieki, Woda Stezenie manganu\nZakres (0,10 - 5) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 5) mg/l"}],"search_zh":"废水、水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb8f","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(2,0 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 - 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 - 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu amonowego\nZakres (2,0 - 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki, Woda Stezenie azotu amonowego\nZakres (2,0 - 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 - 1000) mg/l"}],"search_zh":"废水、水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb90","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(3,0 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(3,0 - 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,0 - 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu Kjeldahla\nZakres (3,0 - 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki, Woda Stezenie azotu Kjeldahla\nZakres (3,0 - 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(3,0 - 1000) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb91","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki, Woda Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"废水、水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb92","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda","test_object_en":"Wastewater, Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda Zawiesiny ogólne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Woda Zawiesiny ogolne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 - 1000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eb93","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 - 10) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 - 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 - 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 10) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb94","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5,0 - 60) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5,0 - 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5,0 - 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C","norm_bases":["PN-EN ISO 7887:2012 metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5,0 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C Woda, Woda do spozycia przez ludzi Barwa\nZakres (5,0 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5,0 - 60) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb95","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(1,0 - 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 - 300) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (1,0 - 300) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994 +Ap1:2009","norm_bases":["PN-ISO 9964-1:1994 +Ap1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie sodu\nZakres (1,0 - 300) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994 +Ap1:2009 Woda, Woda do spozycia przez ludzi Stezenie sodu\nZakres (1,0 - 300) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994 +Ap1:2009","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994 +Ap1:2009","parameters_zh":[{"name":"范围","range":"(1,0 - 300) mg/l"}],"search_zh":"水、生活饮用水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994 +Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钠浓度"},{"_id":"6a5dc9bef1c10c8ce825eb96","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie potasu","methodology_en":"Potassium concentration","parameters":[{"name":"Zakres","range":"(0,10 - 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 200) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie potasu\nZakres (0,10 - 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-2:1994","norm_bases":["PN-ISO 9964-2:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie potasu\nZakres (0,10 - 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994 Woda, Woda do spozycia przez ludzi Stezenie potasu\nZakres (0,10 - 200) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Potassium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-2:1994","parameters_zh":[{"name":"范围","range":"(0,10 - 200) mg/l"}],"search_zh":"水、生活饮用水 钾浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-2:1994","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钾浓度"},{"_id":"6a5dc9bef1c10c8ce825eb97","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Sumaryczna zawartośc wapnia i magnezu (Twardość ogólna)","methodology_en":"Total calcium and magnesium content (Total hardness)","parameters":[{"name":"Zakres","range":"(30 - 600) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(30 - 600) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartośc wapnia i magnezu (Twardość ogólna)\nZakres (30 - 600) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartośc wapnia i magnezu (Twardość ogólna)\nZakres (30 - 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (Twardosc ogolna)\nZakres (30 - 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total calcium and magnesium content (Total hardness) Titrimetric method Range PN-ISO 6059:1999","parameters_zh":[{"name":"范围","range":"(30 - 600) mg/l CaCO3"}],"search_zh":"水、生活饮用水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb98","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 - 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb99","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 - 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 - 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 - 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 - 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 - 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 - 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb9a","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 - 3000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 - 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 - 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 - 3000) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb9b","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,10 - 10) mg/l NH4"}],"parameters_en":[{"name":"Range","range":"(0,10 - 10) mg/l NH4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,10 - 10) mg/l NH4\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,10 - 10) mg/l NH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,10 - 10) mg/l NH4\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 10) mg/l NH4"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb9c","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters":[{"name":"Temperatura wody"},{"name":"Zakres","range":"(5,0 - 35) oC"}],"parameters_en":[{"name":"Water temperature"},{"name":"Range","range":"(5,0 - 35) oC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura wody\nZakres (5,0 - 35) oC","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura wody\nZakres (5,0 - 35) oC PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura wody\nZakres (5,0 - 35) oC PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) Water temperature Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","parameters_zh":[{"name":"水温"},{"name":"范围","range":"(5,0 - 35) oC"}],"search_zh":"生活饮用水 化学和物理检测采样（含感官检测） 水温 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a5dc9bef1c10c8ce825eb9d","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,020 - 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 - 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,020 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,020 - 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total iron concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 10) mg/l"}],"search_zh":"生活饮用水 总铁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb9e","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,015 - 5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,015 - 5) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,015 - 5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,015 - 5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,015 - 5) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,015 - 5) mg/l"}],"search_zh":"生活饮用水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eb9f","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stęzenie miedzi","methodology_en":"Copper concentration","parameters":[{"name":"Zakres","range":"(0,10 - 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 20) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stęzenie miedzi\nZakres (0,10 - 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stęzenie miedzi\nZakres (0,10 - 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Woda do spozycia przez ludzi Stezenie miedzi\nZakres (0,10 - 20) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Copper concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002","parameters_zh":[{"name":"范围","range":"(0,10 - 20) mg/l"}],"search_zh":"生活饮用水 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eba0","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,020 - 30) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 - 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,020 - 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,020 - 30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,020 - 30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 30) mg/l"}],"search_zh":"废水、水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eba1","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"parameters_en":[{"name":"Range","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, Woda, Woda do spozycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 10,0)"}],"search_zh":"废水、水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eba2","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"fluorki","range":"(0,10 - 100) mg/l"},{"name":"chlorki","range":"(10 - 2000) mg/l"},{"name":"azotyny","range":"(0,10 - 35) mg/l"},{"name":"azotany","range":"(1,0 - 500) mg/l"},{"name":"siarczany","range":"(10,0 - 1000) mg/l"},{"name":"Suma chlorków i siarczanów (z obliczeń)"}],"parameters_en":[{"name":"fluorides","range":"(0,10 - 100) mg/l"},{"name":"chlorides","range":"(10 - 2000) mg/l"},{"name":"nitrites","range":"(0,10 - 35) mg/l"},{"name":"nitrates","range":"(1,0 - 500) mg/l"},{"name":"sulfates","range":"(10,0 - 1000) mg/l"},{"name":"Sum of chlorides and sulphates (calculated)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,10 - 100) mg/l\nchlorki (10 - 2000) mg/l\nazotyny (0,10 - 35) mg/l\nazotany (1,0 - 500) mg/l\nsiarczany (10,0 - 1000) mg/l\nSuma chlorków i siarczanów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nfluorki (0,10 - 100) mg/l\nchlorki (10 - 2000) mg/l\nazotyny (0,10 - 35) mg/l\nazotany (1,0 - 500) mg/l\nsiarczany (10,0 - 1000) mg/l\nSuma chlorków i siarczanów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Scieki, Woda, Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nfluorki (0,10 - 100) mg/l\nchlorki (10 - 2000) mg/l\nazotyny (0,10 - 35) mg/l\nazotany (1,0 - 500) mg/l\nsiarczany (10,0 - 1000) mg/l\nSuma chlorkow i siarczanow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Water, Water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) fluorides chlorides nitrites nitrates sulfates Sum of chlorides and sulphates (calculated) PN-EN ISO 10304-1:2009 +AC:2012","methodology_zh":"阴离子浓度","search_zh":"废水、水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 亚硝酸盐 硝酸盐 硫酸盐 氯化物与硫酸盐总量（由计算得出） PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","parameters_zh":[{"name":"氟化物","range":"(0,10 - 100) mg/l"},{"name":"氯化物","range":"(10 - 2000) mg/l"},{"name":"亚硝酸盐","range":"(0,10 - 35) mg/l"},{"name":"硝酸盐","range":"(1,0 - 500) mg/l"},{"name":"硫酸盐","range":"(10,0 - 1000) mg/l"},{"name":"氯化物与硫酸盐总量（由计算得出）"}],"test_object_zh":"废水、水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eba3","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa zapachu TON","methodology_en":"Odour threshold number TON","parameters":[{"name":"Zakres","range":"1"},{"name":"Liczba progowa zapachu TON"},{"name":"Zakres","range":"1 - 32"}],"parameters_en":[{"name":"Range","range":"1"},{"name":"Odour threshold number TON"},{"name":"Range","range":"1 - 32"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony; Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony","Metoda pełna, parzysta, wybór niewymuszony"],"technique_en":"Simplified paired method, non-forced choice; Full paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa zapachu TON\nZakres:\nZakres 1\nLiczba progowa zapachu TON\nZakres 1 - 32\nMetoda uproszczona, parzysta, wybór niewymuszony; Metoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres:\nZakres 1\nLiczba progowa zapachu TON\nZakres 1 - 32\nMetoda uproszczona, parzysta, wybór niewymuszony; Metoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres:\nZakres 1\nLiczba progowa zapachu TON\nZakres 1 - 32\nMetoda uproszczona, parzysta, wybor niewymuszony; Metoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Odour threshold number TON Simplified paired method, non-forced choice; Full paired method, non-forced choice Range Odour threshold number TON Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"1"},{"name":"嗅阈值 TON"},{"name":"范围","range":"1 - 32"}],"search_zh":"生活饮用水 嗅阈值 TON 简化法、成对法、非强制选择；完全法、成对法、非强制选择 范围 嗅阈值 TON 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"嗅阈值 TON","technique_zh":"简化法、成对法、非强制选择；完全法、成对法、非强制选择"},{"_id":"6a5dc9bef1c10c8ce825eba4","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa smaku TFN","methodology_en":"Taste threshold number TFN","parameters":[{"name":"Zakres","range":"1"},{"name":"Liczba progowa smaku TFN"},{"name":"Zakres","range":"1 - 16"}],"parameters_en":[{"name":"Range","range":"1"},{"name":"Taste threshold number TFN"},{"name":"Range","range":"1 - 16"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony; Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony","Metoda pełna, parzysta, wybór niewymuszony"],"technique_en":"Simplified paired method, non-forced choice; Full paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Liczba progowa smaku TFN\nZakres:\nZakres 1\nLiczba progowa smaku TFN\nZakres 1 - 16\nMetoda uproszczona, parzysta, wybór niewymuszony; Metoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres:\nZakres 1\nLiczba progowa smaku TFN\nZakres 1 - 16\nMetoda uproszczona, parzysta, wybór niewymuszony; Metoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres:\nZakres 1\nLiczba progowa smaku TFN\nZakres 1 - 16\nMetoda uproszczona, parzysta, wybor niewymuszony; Metoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Taste threshold number TFN Simplified paired method, non-forced choice; Full paired method, non-forced choice Range Taste threshold number TFN Range PN-EN 1622:2006","parameters_zh":[{"name":"范围","range":"1"},{"name":"味阈值 TFN"},{"name":"范围","range":"1 - 16"}],"search_zh":"生活饮用水 味阈值 TFN 简化法、成对法、非强制选择；完全法、成对法、非强制选择 范围 味阈值 TFN 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"味阈值 TFN","technique_zh":"简化法、成对法、非强制选择；完全法、成对法、非强制选择"},{"_id":"6a5dc9bef1c10c8ce825eba5","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","test_object_en":"Rainwater and snowmelt water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 - 1000) mg/l"}],"search_zh":"雨水与融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水与融雪水"},{"_id":"6a5dc9bef1c10c8ce825eba6","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","test_object_en":"Rainwater and snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水与融雪水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法","test_object_zh":"雨水与融雪水"},{"_id":"6a5dc9bef1c10c8ce825eba7","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eba8","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825eba9","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825ebaa","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825ebab","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825ebac","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825ebad","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825ebae","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825ebaf","lab_id":"69ad52a3de79e566650fb400","country":"PL","accr_number":"AB 795","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"}],"has_pdf":true}