{"lab":{"_id":"69ad52a3de79e566650fb3fe","accr_number":"AB 794","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W GDAŃSKU, ul. Trakt Św. Wojciecha 293","categories":["water","environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":72,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_794.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w gdańsku, ul. trakt św. wojciecha 293 water environment materials other pharma electronics food petro metrology","status":"active","updated_at":"2026-03-08T14:51:40.851Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:40.851Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20794,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/30/P; C/31/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, gleby","en":"Chemical tests and sampling of water, sewage, soil"},{"codes":"C/32","pl":"Badania chemiczne próbek osadów","en":"Chemical tests of sediments"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling water, sewage"}],"issue":{"no":"23","date":"27.02.2026"},"parse_date":"2026-07-20T07:09:50.713Z","parse_source":"script-pdfplumber","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":67,"environment":7,"materials":4,"petro":1},"category_scores":{"water":56.82,"environment":0.62,"materials":0.2,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825eb3c","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Gleba, osady ściekowe","test_object_en":"Soil, sewage sludge","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,001 – 6) mg/kg"}],"parameters_en":[{"name":"Range","range":"(0,001 – 6) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,001 – 6) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-58/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-58/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, osady ściekowe Zawartość rtęci\nZakres (0,001 – 6) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-58/GD wydanie 2, 20 marca 2020 r. Gleba, osady sciekowe Zawartosc rteci\nZakres (0,001 – 6) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-58/GD wydanie 2, 20 marca 2020 r.","categories":["water","environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil, sewage sludge Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-58/GD wydanie 2, 20 marca 2020 r.","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,001 – 6) mg/kg"}],"search_zh":"土壤、污水污泥 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-58/GD wydanie 2, 20 marca 2020 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"土壤、污水污泥"},{"_id":"6a5dc9bef1c10c8ce825eb3d","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Gleba, osady ściekowe","test_object_en":"Soil, sewage sludge","methodology":"Zawartość metali","methodology_en":"Metal content","parameters":[{"name":"As","range":"(5 – 5000) mg/kg"},{"name":"Ba","range":"(1 – 10000) mg/kg"},{"name":"Cd","range":"(0,5 – 10000) mg/kg"},{"name":"Cu","range":"(1 – 10000) mg/kg"},{"name":"Cr","range":"(1 – 10000) mg/kg"},{"name":"Fe","range":"(1 – 10000) mg/kg"},{"name":"Mn","range":"(1 – 10000) mg/kg"},{"name":"Mo","range":"(1 – 10000) mg/kg"},{"name":"Ni","range":"(1 – 10000) mg/kg"},{"name":"Pb","range":"(2 – 10000) mg/kg"},{"name":"V","range":"(1 – 10000) mg/kg"},{"name":"Zn","range":"(1 – 10000) mg/kg"}],"parameters_en":[{"name":"As","range":"(5 – 5000) mg/kg"},{"name":"Ba","range":"(1 – 10000) mg/kg"},{"name":"Cd","range":"(0,5 – 10000) mg/kg"},{"name":"Cu","range":"(1 – 10000) mg/kg"},{"name":"Cr","range":"(1 – 10000) mg/kg"},{"name":"Fe","range":"(1 – 10000) mg/kg"},{"name":"Mn","range":"(1 – 10000) mg/kg"},{"name":"Mo","range":"(1 – 10000) mg/kg"},{"name":"Ni","range":"(1 – 10000) mg/kg"},{"name":"Pb","range":"(2 – 10000) mg/kg"},{"name":"V","range":"(1 – 10000) mg/kg"},{"name":"Zn","range":"(1 – 10000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość metali\nZakres:\nAs (5 – 5000) mg/kg\nBa (1 – 10000) mg/kg\nCd (0,5 – 10000) mg/kg\nCu (1 – 10000) mg/kg\nCr (1 – 10000) mg/kg\nFe (1 – 10000) mg/kg\nMn (1 – 10000) mg/kg\nMo (1 – 10000) mg/kg\nNi (1 – 10000) mg/kg\nPb (2 – 10000) mg/kg\nV (1 – 10000) mg/kg\nZn (1 – 10000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885 : 2009 | PN-ISO 11466:2002 | PN-EN 13346:2002","norm_bases":["PN-EN ISO 11885 : 2009","PN-ISO 11466:2002","PN-EN 13346:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, osady ściekowe Zawartość metali\nZakres:\nAs (5 – 5000) mg/kg\nBa (1 – 10000) mg/kg\nCd (0,5 – 10000) mg/kg\nCu (1 – 10000) mg/kg\nCr (1 – 10000) mg/kg\nFe (1 – 10000) mg/kg\nMn (1 – 10000) mg/kg\nMo (1 – 10000) mg/kg\nNi (1 – 10000) mg/kg\nPb (2 – 10000) mg/kg\nV (1 – 10000) mg/kg\nZn (1 – 10000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885 : 2009 | PN-ISO 11466:2002 | PN-EN 13346:2002 Gleba, osady sciekowe Zawartosc metali\nZakres:\nAs (5 – 5000) mg/kg\nBa (1 – 10000) mg/kg\nCd (0,5 – 10000) mg/kg\nCu (1 – 10000) mg/kg\nCr (1 – 10000) mg/kg\nFe (1 – 10000) mg/kg\nMn (1 – 10000) mg/kg\nMo (1 – 10000) mg/kg\nNi (1 – 10000) mg/kg\nPb (2 – 10000) mg/kg\nV (1 – 10000) mg/kg\nZn (1 – 10000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885 : 2009 | PN-ISO 11466:2002 | PN-EN 13346:2002","categories":["water","materials","environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil, sewage sludge Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) As Ba Cd Cu Cr Fe Mn Mo Ni Pb V Zn PN-EN ISO 11885 : 2009 | PN-ISO 11466:2002 | PN-EN 13346:2002","parameters_zh":[{"name":"As","range":"(5 – 5000) mg/kg"},{"name":"Ba","range":"(1 – 10000) mg/kg"},{"name":"Cd","range":"(0,5 – 10000) mg/kg"},{"name":"Cu","range":"(1 – 10000) mg/kg"},{"name":"Cr","range":"(1 – 10000) mg/kg"},{"name":"Fe","range":"(1 – 10000) mg/kg"},{"name":"Mn","range":"(1 – 10000) mg/kg"},{"name":"Mo","range":"(1 – 10000) mg/kg"},{"name":"Ni","range":"(1 – 10000) mg/kg"},{"name":"Pb","range":"(2 – 10000) mg/kg"},{"name":"V","range":"(1 – 10000) mg/kg"},{"name":"Zn","range":"(1 – 10000) mg/kg"}],"search_zh":"土壤、污水污泥 金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） As Ba Cd Cu Cr Fe Mn Mo Ni Pb V Zn PN-EN ISO 11885 : 2009 | PN-ISO 11466:2002 | PN-EN 13346:2002","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属含量","test_object_zh":"土壤、污水污泥"},{"_id":"6a5dc9bef1c10c8ce825eb3e","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,02 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 10) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,02 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,02 – 10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,02 – 10) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 10) mg/l"}],"search_zh":"水、废水 总磷浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb3f","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 100) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,05 – 100) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/dm3"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb40","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,020 – 7,0) mg/dm3"},{"name":"Stężenie jonu amonowego (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,020 – 7,0) mg/dm3"},{"name":"Ammonium ion concentration (calculated)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,020 – 7,0) mg/dm3\nStężenie jonu amonowego (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,020 – 7,0) mg/dm3\nStężenie jonu amonowego (z obliczeń)\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres:\nZakres (0,020 – 7,0) mg/dm3\nStezenie jonu amonowego (z obliczen)\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration (calculated) PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 7,0) mg/dm3"},{"name":"铵离子浓度（由计算得出）"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 铵离子浓度（由计算得出） PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb41","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie sumy azotu azotanowego i azotu azotynowego","methodology_en":"Concentration of the sum of nitrate nitrogen and nitrite nitrogen","parameters":[{"name":"Zakres","range":"(0,020 – 150) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,020 – 150) mg/dm3"}],"technique":"Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","techniques":["Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną"],"technique_en":"Flow injection analysis (FIA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie sumy azotu azotanowego i azotu azotynowego\nZakres (0,020 – 150) mg/dm3\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie sumy azotu azotanowego i azotu azotynowego\nZakres (0,020 – 150) mg/dm3\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie sumy azotu azotanowego i azotu azotynowego\nZakres (0,020 – 150) mg/dm3\nMetoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of the sum of nitrate nitrogen and nitrite nitrogen Flow injection analysis (FIA) with spectrophotometric detection Range PN-EN ISO 13395:2001","parameters_zh":[{"name":"范围","range":"(0,020 – 150) mg/dm3"}],"search_zh":"水、废水 流动注射分析（FIA）分光光度检测法 范围 PN-EN ISO 13395:2001","test_object_zh":"水、废水","technique_zh":"流动注射分析（FIA）分光光度检测法"},{"_id":"6a5dc9bef1c10c8ce825eb42","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"Cl-, SO42","range":"(0,10 – 200) mg/dm3"},{"name":"F ̅","range":"(0,10 – 10) mg/dm3"},{"name":"NO3","range":"(0,040 – 400) mg/dm3"}],"parameters_en":[{"name":"Cl-, SO42","range":"(0,10 – 200) mg/dm3"},{"name":"F ̅","range":"(0,10 – 10) mg/dm3"},{"name":"NO3","range":"(0,040 – 400) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nCl-, SO42 (0,10 – 200) mg/dm3\nF ̅ (0,10 – 10) mg/dm3\nNO3 (0,040 – 400) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie anionów\nZakres:\nCl-, SO42 (0,10 – 200) mg/dm3\nF ̅ (0,10 – 10) mg/dm3\nNO3 (0,040 – 400) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda, scieki Stezenie anionow\nZakres:\nCl-, SO42 (0,10 – 200) mg/dm3\nF  (0,10 – 10) mg/dm3\nNO3 (0,040 – 400) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Cl-, SO42 F ̅ NO3 PN-EN ISO 10304-1:2009 + AC:2012","methodology_zh":"阴离子浓度","search_zh":"水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb43","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego (z obliczeń)","methodology_en":"Nitrate nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009 + AC:2012 Woda, scieki Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009 + AC:2012","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009 + AC:2012","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb44","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego (z obliczeń)","methodology_en":"Nitrate nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PB-66/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-66/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PB-66/GD wydanie 2, 20 marca 2020 r. Woda, scieki Stezenie azotu azotanowego (z obliczen) PB-66/GD wydanie 2, 20 marca 2020 r.","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PB-66/GD wydanie 2, 20 marca 2020 r.","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PB-66/GD wydanie 2, 20 marca 2020 r.","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb45","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforanów","methodology_en":"Phosphate concentration","parameters":[{"name":"Zakres","range":"(0,02 – 300) mg/dm3"},{"name":"Stężenie fosforu (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,02 – 300) mg/dm3"},{"name":"Phosphorus concentration (calculated)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforanów\nZakres:\nZakres (0,02 – 300) mg/dm3\nStężenie fosforu (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres:\nZakres (0,02 – 300) mg/dm3\nStężenie fosforu (z obliczeń)\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010 Woda, scieki Stezenie fosforanow\nZakres:\nZakres (0,02 – 300) mg/dm3\nStezenie fosforu (z obliczen)\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phosphate concentration Spectrophotometric method Range Phosphorus concentration (calculated) PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,02 – 300) mg/dm3"},{"name":"Stężenie fosforu (z obliczeń)"}],"search_zh":"水、废水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a5dc9bef1c10c8ce825eb46","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"Ca","range":"(0,5 – 1000) mg/dm3"},{"name":"K","range":"(0,1 – 150) mg/dm3"},{"name":"Mg","range":"(0,1 – 100) mg/dm3"},{"name":"Na","range":"(0,1 – 200) mg/dm3"}],"parameters_en":[{"name":"Ca","range":"(0,5 – 1000) mg/dm3"},{"name":"K","range":"(0,1 – 150) mg/dm3"},{"name":"Mg","range":"(0,1 – 100) mg/dm3"},{"name":"Na","range":"(0,1 – 200) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nCa (0,5 – 1000) mg/dm3\nK (0,1 – 150) mg/dm3\nMg (0,1 – 100) mg/dm3\nNa (0,1 – 200) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-49/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-49/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nCa (0,5 – 1000) mg/dm3\nK (0,1 – 150) mg/dm3\nMg (0,1 – 100) mg/dm3\nNa (0,1 – 200) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-49/GD wydanie 2, 20 marca 2020 r. Woda, scieki Stezenie metali\nZakres:\nCa (0,5 – 1000) mg/dm3\nK (0,1 – 150) mg/dm3\nMg (0,1 – 100) mg/dm3\nNa (0,1 – 200) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-49/GD wydanie 2, 20 marca 2020 r.","categories":["water","materials"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Ca K Mg Na PB-49/GD wydanie 2, 20 marca 2020 r.","methodology_zh":"金属浓度","search_zh":"水、废水 金属浓度 火焰原子吸收光谱法（FAAS） Ca K Mg Na PB-49/GD wydanie 2, 20 marca 2020 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","parameters_zh":[{"name":"Ca","range":"(0,5 – 1000) mg/dm3"},{"name":"K","range":"(0,1 – 150) mg/dm3"},{"name":"Mg","range":"(0,1 – 100) mg/dm3"},{"name":"Na","range":"(0,1 – 200) mg/dm3"}]},{"_id":"6a5dc9bef1c10c8ce825eb47","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"10 μS/cm – 20 mS/cm"}],"parameters_en":[{"name":"Range","range":"10 μS/cm – 20 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres 10 μS/cm – 20 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres 10 μS/cm – 20 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres 10 μS/cm – 20 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"10 μS/cm – 20 mS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb48","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego Kjeldahla (z obliczeń)","methodology_en":"Total Kjeldahl nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Kjeldahla (z obliczeń)","reference":"PB-75/GD wydanie 1, 06 marca 2025","norm_bases":["PB-75/GD wydanie 1, 06 marca 2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego Kjeldahla (z obliczeń) PB-75/GD wydanie 1, 06 marca 2025 Woda, scieki Stezenie azotu ogolnego Kjeldahla (z obliczen) PB-75/GD wydanie 1, 06 marca 2025","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total Kjeldahl nitrogen concentration (calculated) PB-75/GD wydanie 1, 06 marca 2025","search_zh":"水、废水 PB-75/GD wydanie 1, 06 marca 2025","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb49","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 150) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 150) mg/dm3"}],"technique":"Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","techniques":["Metoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną"],"technique_en":"Flow injection analysis (FIA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (0,05 – 150) mg/dm3\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11905-1:2001","norm_bases":["PN-EN ISO 11905-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (0,05 – 150) mg/dm3\nMetoda wstrzykowej analizy przepływowej (FIA) z detekcją spektrofotometryczną PN-EN ISO 11905-1:2001 Woda, scieki Stezenie azotu ogolnego\nZakres (0,05 – 150) mg/dm3\nMetoda wstrzykowej analizy przeplywowej (FIA) z detekcja spektrofotometryczna PN-EN ISO 11905-1:2001","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration Flow injection analysis (FIA) with spectrophotometric detection Range PN-EN ISO 11905-1:2001","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 150) mg/dm3"}],"search_zh":"水、废水 总氮浓度 流动注射分析（FIA）分光光度检测法 范围 PN-EN ISO 11905-1:2001","test_object_zh":"水、废水","technique_zh":"流动注射分析（FIA）分光光度检测法"},{"_id":"6a5dc9bef1c10c8ce825eb4a","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"Ag","range":"(0,00100 – 10,00) mg/dm3"},{"name":"Al","range":"(0,0050 – 10,0) mg/dm3"},{"name":"As","range":"(0,0050 – 10,0) mg/dm3"},{"name":"B","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ba","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Be","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Ca","range":"(0,050 – 1000) mg/dm3"},{"name":"Cd","range":"(0,00050 – 10,0) mg/dm3"},{"name":"Co","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Cr","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Cu","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Fe","range":"(0,0050 – 1000) mg/dm3"},{"name":"K","range":"(0,050 – 1000) mg/dm3"},{"name":"Mg","range":"(0,050 – 1000) mg/dm3"},{"name":"Mn","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Mo","range":"(0,00100 – 10,00) mg/dm3"},{"name":"Na","range":"(0,050 – 1000) mg/dm3"},{"name":"Ni","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Pb","range":"(0,00200 – 10,0) mg/dm3"},{"name":"Sb","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Se","range":"(0,0050 – 10,0) mg/dm3"},{"name":"Si","range":"(0,100 – 100) mg/dm3"},{"name":"Sn","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ti","range":"(0,0050 – 10,0) mg/dm3"},{"name":"Tl","range":"(0,0050 – 10,0) mg/dm3"},{"name":"V","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Zn","range":"(0,00100 – 10,0) mg/dm3"}],"parameters_en":[{"name":"Ag","range":"(0,00100 – 10,00) mg/dm3"},{"name":"Al","range":"(0,0050 – 10,0) mg/dm3"},{"name":"As","range":"(0,0050 – 10,0) mg/dm3"},{"name":"B","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ba","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Be","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Ca","range":"(0,050 – 1000) mg/dm3"},{"name":"Cd","range":"(0,00050 – 10,0) mg/dm3"},{"name":"Co","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Cr","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Cu","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Fe","range":"(0,0050 – 1000) mg/dm3"},{"name":"K","range":"(0,050 – 1000) mg/dm3"},{"name":"Mg","range":"(0,050 – 1000) mg/dm3"},{"name":"Mn","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Mo","range":"(0,00100 – 10,00) mg/dm3"},{"name":"Na","range":"(0,050 – 1000) mg/dm3"},{"name":"Ni","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Pb","range":"(0,00200 – 10,0) mg/dm3"},{"name":"Sb","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Se","range":"(0,0050 – 10,0) mg/dm3"},{"name":"Si","range":"(0,100 – 100) mg/dm3"},{"name":"Sn","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ti","range":"(0,0050 – 10,0) mg/dm3"},{"name":"Tl","range":"(0,0050 – 10,0) mg/dm3"},{"name":"V","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Zn","range":"(0,00100 – 10,0) mg/dm3"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nAg (0,00100 – 10,00) mg/dm3\nAl (0,0050 – 10,0) mg/dm3\nAs (0,0050 – 10,0) mg/dm3\nB (0,0100 – 10,0) mg/dm3\nBa (0,00100 – 10,0) mg/dm3\nBe (0,00100 – 10,0) mg/dm3\nCa (0,050 – 1000) mg/dm3\nCd (0,00050 – 10,0) mg/dm3\nCo (0,00100 – 10,0) mg/dm3\nCr (0,00100 – 10,0) mg/dm3\nCu (0,00100 – 10,0) mg/dm3\nFe (0,0050 – 1000) mg/dm3\nK (0,050 – 1000) mg/dm3\nMg (0,050 – 1000) mg/dm3\nMn (0,00100 – 10,0) mg/dm3\nMo (0,00100 – 10,00) mg/dm3\nNa (0,050 – 1000) mg/dm3\nNi (0,00100 – 10,0) mg/dm3\nPb (0,00200 – 10,0) mg/dm3\nSb (0,00100 – 10,0) mg/dm3\nSe (0,0050 – 10,0) mg/dm3\nSi (0,100 – 100) mg/dm3\nSn (0,0100 – 10,0) mg/dm3\nTi (0,0050 – 10,0) mg/dm3\nTl (0,0050 – 10,0) mg/dm3\nV (0,00100 – 10,0) mg/dm3\nZn (0,00100 – 10,0) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nAg (0,00100 – 10,00) mg/dm3\nAl (0,0050 – 10,0) mg/dm3\nAs (0,0050 – 10,0) mg/dm3\nB (0,0100 – 10,0) mg/dm3\nBa (0,00100 – 10,0) mg/dm3\nBe (0,00100 – 10,0) mg/dm3\nCa (0,050 – 1000) mg/dm3\nCd (0,00050 – 10,0) mg/dm3\nCo (0,00100 – 10,0) mg/dm3\nCr (0,00100 – 10,0) mg/dm3\nCu (0,00100 – 10,0) mg/dm3\nFe (0,0050 – 1000) mg/dm3\nK (0,050 – 1000) mg/dm3\nMg (0,050 – 1000) mg/dm3\nMn (0,00100 – 10,0) mg/dm3\nMo (0,00100 – 10,00) mg/dm3\nNa (0,050 – 1000) mg/dm3\nNi (0,00100 – 10,0) mg/dm3\nPb (0,00200 – 10,0) mg/dm3\nSb (0,00100 – 10,0) mg/dm3\nSe (0,0050 – 10,0) mg/dm3\nSi (0,100 – 100) mg/dm3\nSn (0,0100 – 10,0) mg/dm3\nTi (0,0050 – 10,0) mg/dm3\nTl (0,0050 – 10,0) mg/dm3\nV (0,00100 – 10,0) mg/dm3\nZn (0,00100 – 10,0) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie metali\nZakres:\nAg (0,00100 – 10,00) mg/dm3\nAl (0,0050 – 10,0) mg/dm3\nAs (0,0050 – 10,0) mg/dm3\nB (0,0100 – 10,0) mg/dm3\nBa (0,00100 – 10,0) mg/dm3\nBe (0,00100 – 10,0) mg/dm3\nCa (0,050 – 1000) mg/dm3\nCd (0,00050 – 10,0) mg/dm3\nCo (0,00100 – 10,0) mg/dm3\nCr (0,00100 – 10,0) mg/dm3\nCu (0,00100 – 10,0) mg/dm3\nFe (0,0050 – 1000) mg/dm3\nK (0,050 – 1000) mg/dm3\nMg (0,050 – 1000) mg/dm3\nMn (0,00100 – 10,0) mg/dm3\nMo (0,00100 – 10,00) mg/dm3\nNa (0,050 – 1000) mg/dm3\nNi (0,00100 – 10,0) mg/dm3\nPb (0,00200 – 10,0) mg/dm3\nSb (0,00100 – 10,0) mg/dm3\nSe (0,0050 – 10,0) mg/dm3\nSi (0,100 – 100) mg/dm3\nSn (0,0100 – 10,0) mg/dm3\nTi (0,0050 – 10,0) mg/dm3\nTl (0,0050 – 10,0) mg/dm3\nV (0,00100 – 10,0) mg/dm3\nZn (0,00100 – 10,0) mg/dm3\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) Ag Al As B Ba Be Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Si Sn Ti Tl V Zn PN-EN ISO 11885:2009","methodology_zh":"金属浓度","parameters_zh":[{"name":"Ag","range":"(0,00100 – 10,00) mg/dm3"},{"name":"Al","range":"(0,0050 – 10,0) mg/dm3"},{"name":"As","range":"(0,0050 – 10,0) mg/dm3"},{"name":"B","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ba","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Be","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Ca","range":"(0,050 – 1000) mg/dm3"},{"name":"Cd","range":"(0,00050 – 10,0) mg/dm3"},{"name":"Co","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Cr","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Cu","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Fe","range":"(0,0050 – 1000) mg/dm3"},{"name":"K","range":"(0,050 – 1000) mg/dm3"},{"name":"Mg","range":"(0,050 – 1000) mg/dm3"},{"name":"Mn","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Mo","range":"(0,00100 – 10,00) mg/dm3"},{"name":"Na","range":"(0,050 – 1000) mg/dm3"},{"name":"Ni","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Pb","range":"(0,00200 – 10,0) mg/dm3"},{"name":"Sb","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Se","range":"(0,0050 – 10,0) mg/dm3"},{"name":"Si","range":"(0,100 – 100) mg/dm3"},{"name":"Sn","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ti","range":"(0,0050 – 10,0) mg/dm3"},{"name":"Tl","range":"(0,0050 – 10,0) mg/dm3"},{"name":"V","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Zn","range":"(0,00100 – 10,0) mg/dm3"}],"search_zh":"水、废水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Ag Al As B Ba Be Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Si Sn Ti Tl V Zn PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb4b","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"Ag","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Al","range":"(0,00100 – 10,0) mg/dm3"},{"name":"As","range":"(0,000100 – 10,0) mg/dm"},{"name":"B","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ba","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Be","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Ca","range":"(0,050 – 1000) mg/dm3"},{"name":"Cd","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"Co","range":"(0,000050– 10,0) mg/dm3"},{"name":"Cr","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Cu","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Fe","range":"(0,00100 – 1000) mg/dm3"},{"name":"K","range":"(0,0100 – 1000) mg/dm3"},{"name":"Li","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Mg","range":"(0,0100 – 1000) mg/dm3"},{"name":"Mn","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Mo","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Na","range":"(0,0100 – 1000) mg/dm3"},{"name":"Ni","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Pb","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"Sb","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Se","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Sn","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Sr","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Ti","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Tl","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"V","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Zn","range":"(0,000100 – 10,0) mg/dm3"}],"parameters_en":[{"name":"Ag","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Al","range":"(0,00100 – 10,0) mg/dm3"},{"name":"As","range":"(0,000100 – 10,0) mg/dm"},{"name":"B","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ba","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Be","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Ca","range":"(0,050 – 1000) mg/dm3"},{"name":"Cd","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"Co","range":"(0,000050– 10,0) mg/dm3"},{"name":"Cr","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Cu","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Fe","range":"(0,00100 – 1000) mg/dm3"},{"name":"K","range":"(0,0100 – 1000) mg/dm3"},{"name":"Li","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Mg","range":"(0,0100 – 1000) mg/dm3"},{"name":"Mn","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Mo","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Na","range":"(0,0100 – 1000) mg/dm3"},{"name":"Ni","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Pb","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"Sb","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Se","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Sn","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Sr","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Ti","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Tl","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"V","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Zn","range":"(0,000100 – 10,0) mg/dm3"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie metali\nZakres:\nAg (0,000100 – 10,0) mg/dm3\nAl (0,00100 – 10,0) mg/dm3\nAs (0,000100 – 10,0) mg/dm\nB (0,0100 – 10,0) mg/dm3\nBa (0,000100 – 10,0) mg/dm3\nBe (0,000100 – 10,0) mg/dm3\nCa (0,050 – 1000) mg/dm3\nCd (0,0000100 – 10,0) mg/dm3\nCo (0,000050– 10,0) mg/dm3\nCr (0,000050 – 10,0) mg/dm3\nCu (0,000050 – 10,0) mg/dm3\nFe (0,00100 – 1000) mg/dm3\nK (0,0100 – 1000) mg/dm3\nLi (0,00100 – 10,0) mg/dm3\nMg (0,0100 – 1000) mg/dm3\nMn (0,000100 – 10,0) mg/dm3\nMo (0,000100 – 10,0) mg/dm3\nNa (0,0100 – 1000) mg/dm3\nNi (0,000050 – 10,0) mg/dm3\nPb (0,0000100 – 10,0) mg/dm3\nSb (0,000050 – 10,0) mg/dm3\nSe (0,00100 – 10,0) mg/dm3\nSn (0,00100 – 10,0) mg/dm3\nSr (0,000100 – 10,0) mg/dm3\nTi (0,000100 – 10,0) mg/dm3\nTl (0,0000100 – 10,0) mg/dm3\nV (0,000100 – 10,0) mg/dm3\nZn (0,000100 – 10,0) mg/dm3\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali\nZakres:\nAg (0,000100 – 10,0) mg/dm3\nAl (0,00100 – 10,0) mg/dm3\nAs (0,000100 – 10,0) mg/dm\nB (0,0100 – 10,0) mg/dm3\nBa (0,000100 – 10,0) mg/dm3\nBe (0,000100 – 10,0) mg/dm3\nCa (0,050 – 1000) mg/dm3\nCd (0,0000100 – 10,0) mg/dm3\nCo (0,000050– 10,0) mg/dm3\nCr (0,000050 – 10,0) mg/dm3\nCu (0,000050 – 10,0) mg/dm3\nFe (0,00100 – 1000) mg/dm3\nK (0,0100 – 1000) mg/dm3\nLi (0,00100 – 10,0) mg/dm3\nMg (0,0100 – 1000) mg/dm3\nMn (0,000100 – 10,0) mg/dm3\nMo (0,000100 – 10,0) mg/dm3\nNa (0,0100 – 1000) mg/dm3\nNi (0,000050 – 10,0) mg/dm3\nPb (0,0000100 – 10,0) mg/dm3\nSb (0,000050 – 10,0) mg/dm3\nSe (0,00100 – 10,0) mg/dm3\nSn (0,00100 – 10,0) mg/dm3\nSr (0,000100 – 10,0) mg/dm3\nTi (0,000100 – 10,0) mg/dm3\nTl (0,0000100 – 10,0) mg/dm3\nV (0,000100 – 10,0) mg/dm3\nZn (0,000100 – 10,0) mg/dm3\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda, scieki Stezenie metali\nZakres:\nAg (0,000100 – 10,0) mg/dm3\nAl (0,00100 – 10,0) mg/dm3\nAs (0,000100 – 10,0) mg/dm\nB (0,0100 – 10,0) mg/dm3\nBa (0,000100 – 10,0) mg/dm3\nBe (0,000100 – 10,0) mg/dm3\nCa (0,050 – 1000) mg/dm3\nCd (0,0000100 – 10,0) mg/dm3\nCo (0,000050– 10,0) mg/dm3\nCr (0,000050 – 10,0) mg/dm3\nCu (0,000050 – 10,0) mg/dm3\nFe (0,00100 – 1000) mg/dm3\nK (0,0100 – 1000) mg/dm3\nLi (0,00100 – 10,0) mg/dm3\nMg (0,0100 – 1000) mg/dm3\nMn (0,000100 – 10,0) mg/dm3\nMo (0,000100 – 10,0) mg/dm3\nNa (0,0100 – 1000) mg/dm3\nNi (0,000050 – 10,0) mg/dm3\nPb (0,0000100 – 10,0) mg/dm3\nSb (0,000050 – 10,0) mg/dm3\nSe (0,00100 – 10,0) mg/dm3\nSn (0,00100 – 10,0) mg/dm3\nSr (0,000100 – 10,0) mg/dm3\nTi (0,000100 – 10,0) mg/dm3\nTl (0,0000100 – 10,0) mg/dm3\nV (0,000100 – 10,0) mg/dm3\nZn (0,000100 – 10,0) mg/dm3\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) Ag Al As B Ba Be Ca Cd Co Cr Cu Fe K Li Mg Mn Mo Na Ni Pb Sb Se Sn Sr Ti Tl V Zn PN-EN ISO 17294-2:2024-04","methodology_zh":"金属浓度","parameters_zh":[{"name":"Ag","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Al","range":"(0,00100 – 10,0) mg/dm3"},{"name":"As","range":"(0,000100 – 10,0) mg/dm"},{"name":"B","range":"(0,0100 – 10,0) mg/dm3"},{"name":"Ba","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Be","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Ca","range":"(0,050 – 1000) mg/dm3"},{"name":"Cd","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"Co","range":"(0,000050– 10,0) mg/dm3"},{"name":"Cr","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Cu","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Fe","range":"(0,00100 – 1000) mg/dm3"},{"name":"K","range":"(0,0100 – 1000) mg/dm3"},{"name":"Li","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Mg","range":"(0,0100 – 1000) mg/dm3"},{"name":"Mn","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Mo","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Na","range":"(0,0100 – 1000) mg/dm3"},{"name":"Ni","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Pb","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"Sb","range":"(0,000050 – 10,0) mg/dm3"},{"name":"Se","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Sn","range":"(0,00100 – 10,0) mg/dm3"},{"name":"Sr","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Ti","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Tl","range":"(0,0000100 – 10,0) mg/dm3"},{"name":"V","range":"(0,000100 – 10,0) mg/dm3"},{"name":"Zn","range":"(0,000100 – 10,0) mg/dm3"}],"search_zh":"水、废水 金属浓度 电感耦合等离子体质谱法（ICP-MS） Ag Al As B Ba Be Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni Pb Sb Se Sn Sr Ti Tl V Zn PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb4c","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,5 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,5 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,5 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 1000) mg/dm3"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb4d","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie jonu amonowego (z obliczeń)","methodology_en":"Ammonium ion concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie jonu amonowego (z obliczeń) PN-ISO 5664:2002 Woda, scieki Stezenie jonu amonowego (z obliczen) PN-ISO 5664:2002","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium ion concentration (calculated) PN-ISO 5664:2002","search_zh":"水、废水 铵离子浓度（由计算得出） PN-ISO 5664:2002","test_object_zh":"水、废水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb4e","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,002 – 2,00) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,002 – 2,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 2,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,002 – 2,00) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,002 – 2,00) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 2,00) mg/dm3"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb4f","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotynów (z obliczeń)","methodology_en":"Nitrite concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotynów (z obliczeń) PN-EN 26777:1999 Woda, scieki Stezenie azotynow (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite concentration (calculated) PN-EN 26777:1999","search_zh":"水、废水 亚硝酸盐浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb50","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","norm_bases":["PB-26/CLB wydanie 1 z dnia 16.01.2026 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wydanie 1 z dnia 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb51","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego Kjeldahla","methodology_en":"Total Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu ogolnego Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/dm3"}],"search_zh":"水、废水 凯氏总氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"凯氏总氮浓度"},{"_id":"6a5dc9bef1c10c8ce825eb52","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego Kjeldahla","methodology_en":"Total Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,50 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 100) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Kjeldahla\nZakres (0,50 – 100) mg/dm3\nMetoda miareczkowa","reference":"PB-68/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-68/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego Kjeldahla\nZakres (0,50 – 100) mg/dm3\nMetoda miareczkowa PB-68/GD wydanie 2, 20 marca 2020 r. Woda, scieki Stezenie azotu ogolnego Kjeldahla\nZakres (0,50 – 100) mg/dm3\nMetoda miareczkowa PB-68/GD wydanie 2, 20 marca 2020 r.","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total Kjeldahl nitrogen concentration Titrimetric method Range PB-68/GD wydanie 2, 20 marca 2020 r.","parameters_zh":[{"name":"范围","range":"(0,50 – 100) mg/dm3"}],"search_zh":"水、废水 凯氏总氮浓度 滴定法 范围 PB-68/GD wydanie 2, 20 marca 2020 r.","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"凯氏总氮浓度"},{"_id":"6a5dc9bef1c10c8ce825eb53","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6) mg/dm3 O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb54","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 6000) mg/dm3 O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 6000) mg/dm3 O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb55","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","methodology_en":"Chemical oxygen demand - COD","parameters":[{"name":"Zakres","range":"5 mg/dm3– 20 g/dm3 O2"}],"parameters_en":[{"name":"Range","range":"5 mg/dm3– 20 g/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres 5 mg/dm3– 20 g/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres 5 mg/dm3– 20 g/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres 5 mg/dm3– 20 g/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand - COD Spectrophotometric method Range PN-ISO 15705:2005","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"5 mg/dm3– 20 g/dm3 O2"}],"search_zh":"水、废水 化学需氧量 ChZT（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb56","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(5 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/dm3"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb57","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,05 – 100) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,05 – 100) mg/dm3\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,05 – 100) mg/dm3\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/dm3"}],"search_zh":"水、废水 矿物油指数 气相色谱-火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a5dc9bef1c10c8ce825eb58","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb59","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ogólnego węgiela","methodology_en":"Total carbon concentration","parameters":[{"name":"organicznego (OWO) Stężenie rozpuszczonego węgla"},{"name":"organicznego (RWO)"},{"name":"Zakres","range":"(0,5 – 1000) mg/dm3"}],"parameters_en":[{"name":"organic (TOC) Concentration of dissolved carbon"},{"name":"organic (DOC)"},{"name":"Range","range":"(0,5 – 1000) mg/dm3"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"technique_en":"Spectrometry method in the infrared range (IR)","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgiela\nZakres:\norganicznego (OWO) Stężenie rozpuszczonego węgla\norganicznego (RWO)\nZakres (0,5 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ogólnego węgiela\nZakres:\norganicznego (OWO) Stężenie rozpuszczonego węgla\norganicznego (RWO)\nZakres (0,5 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda, scieki Stezenie ogolnego wegiela\nZakres:\norganicznego (OWO) Stezenie rozpuszczonego wegla\norganicznego (RWO)\nZakres (0,5 – 1000) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total carbon concentration Spectrometry method in the infrared range (IR) organic (TOC) Concentration of dissolved carbon organic (DOC) Range PN-EN 1484:1999","parameters_zh":[{"name":"有机碳（TOC）；溶解性碳浓度"},{"name":"有机的（溶解性有机碳 DOC）"},{"name":"范围","range":"(0,5 – 1000) mg/dm3"}],"search_zh":"水、废水 红外光谱法（IR） 有机碳（TOC）；溶解性碳浓度 有机的（溶解性有机碳 DOC） 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法（IR）"},{"_id":"6a5dc9bef1c10c8ce825eb5a","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(20 – 600) ng/dm3"}],"parameters_en":[{"name":"Range","range":"(20 – 600) ng/dm3"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej","techniques":["Metoda atomowej spektrometrii fluorescencyjnej"],"technique_en":"Atomic fluorescence spectrometry","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (20 – 600) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej","reference":"PB-6/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-6/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (20 – 600) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej PB-6/GD wydanie 2, 20 marca 2020 r. Woda, scieki Stezenie rteci\nZakres (20 – 600) ng/dm3\nMetoda atomowej spektrometrii fluorescencyjnej PB-6/GD wydanie 2, 20 marca 2020 r.","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Mercury concentration Atomic fluorescence spectrometry Range PB-6/GD wydanie 2, 20 marca 2020 r.","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(20 – 600) ng/dm3"}],"search_zh":"水、废水 汞浓度 原子荧光光谱法 范围 PB-6/GD wydanie 2, 20 marca 2020 r.","test_object_zh":"水、废水","technique_zh":"原子荧光光谱法"},{"_id":"6a5dc9bef1c10c8ce825eb5b","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Suma węglowodorów alifatycznych","methodology_en":"Sum of aliphatic hydrocarbons","parameters":[{"name":"Zakres","range":"(0,1 – 30) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30) mg/dm3"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"technique_en":"Spectrometry method in the infrared range (IR)","computed":[],"computed_en":[],"activity":"Suma węglowodorów alifatycznych\nZakres (0,1 – 30) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"PB-32/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-32/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Suma węglowodorów alifatycznych\nZakres (0,1 – 30) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PB-32/GD wydanie 2, 20 marca 2020 r. Woda, scieki Suma weglowodorow alifatycznych\nZakres (0,1 – 30) mg/dm3\nMetoda spektrometrii w zakresie podczerwieni (IR) PB-32/GD wydanie 2, 20 marca 2020 r.","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sum of aliphatic hydrocarbons Spectrometry method in the infrared range (IR) Range PB-32/GD wydanie 2, 20 marca 2020 r.","parameters_zh":[{"name":"范围","range":"(0,1 – 30) mg/dm3"}],"search_zh":"水、废水 红外光谱法（IR） 范围 PB-32/GD wydanie 2, 20 marca 2020 r.","test_object_zh":"水、废水","technique_zh":"红外光谱法（IR）"},{"_id":"6a5dc9bef1c10c8ce825eb5c","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/dm3"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb5d","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie WWA: acenaften","methodology_en":"PAH concentration: acenaphthene","parameters":[{"name":"fluoren"},{"name":"fenantren"},{"name":"antracen"},{"name":"fluoranten"},{"name":"piren"},{"name":"benzo(a)antracen"},{"name":"chryzen"},{"name":"benzo(a)fluoranten"},{"name":"benzo(b)fluoranten"},{"name":"benzo(k)fluoranten"},{"name":"benzo(a,h)antracen"},{"name":"Zakres","range":"(0,001 – 2,0) μg/dm3"},{"name":"benzo(a)piren"},{"name":"Zakres","range":"(0,00006 – 2) μg/dm3"},{"name":"benzo(g,h,i)perylen indeno","range":"(1,2,3-c,d)piren"},{"name":"Zakres","range":"(0,0003 – 2) μg/dm3"}],"parameters_en":[{"name":"fluorene"},{"name":"phenanthrene"},{"name":"anthracene"},{"name":"fluoranthene"},{"name":"pyrene"},{"name":"benzo(a)anthracene"},{"name":"chrysene"},{"name":"benzo(a)fluoranthene"},{"name":"benzo(b)fluoranthene"},{"name":"benzo(k)fluoranthene"},{"name":"benzo(a,h)anthracene"},{"name":"Range","range":"(0,001 – 2,0) μg/dm3"},{"name":"benzo(a)pyrene"},{"name":"Range","range":"(0,00006 – 2) μg/dm3"},{"name":"benzo(g,h,i)perylene indeno","range":"(1,2,3-c,d)piren"},{"name":"Range","range":"(0,0003 – 2) μg/dm3"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC - FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC - FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC - FLD)","computed":[],"computed_en":[],"activity":"Stężenie WWA: acenaften\nZakres:\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(a)fluoranten\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a,h)antracen\nZakres (0,001 – 2,0) μg/dm3\nbenzo(a)piren\nZakres (0,00006 – 2) μg/dm3\nbenzo(g,h,i)perylen indeno (1,2,3-c,d)piren\nZakres (0,0003 – 2) μg/dm3\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC - FLD)","reference":"PB-10/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-10/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie WWA: acenaften\nZakres:\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(a)fluoranten\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a,h)antracen\nZakres (0,001 – 2,0) μg/dm3\nbenzo(a)piren\nZakres (0,00006 – 2) μg/dm3\nbenzo(g,h,i)perylen indeno (1,2,3-c,d)piren\nZakres (0,0003 – 2) μg/dm3\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC - FLD) PB-10/GD wydanie 2, 20 marca 2020 r. Woda, scieki Stezenie WWA: acenaften\nZakres:\nfluoren\nfenantren\nantracen\nfluoranten\npiren\nbenzo(a)antracen\nchryzen\nbenzo(a)fluoranten\nbenzo(b)fluoranten\nbenzo(k)fluoranten\nbenzo(a,h)antracen\nZakres (0,001 – 2,0) μg/dm3\nbenzo(a)piren\nZakres (0,00006 – 2) μg/dm3\nbenzo(g,h,i)perylen indeno (1,2,3-c,d)piren\nZakres (0,0003 – 2) μg/dm3\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC - FLD) PB-10/GD wydanie 2, 20 marca 2020 r.","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater PAH concentration: acenaphthene High-performance liquid chromatography with fluorescence detection (HPLC - FLD) fluorene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(a)fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a,h)anthracene Range benzo(a)pyrene Range benzo(g,h,i)perylene indeno Range PB-10/GD wydanie 2, 20 marca 2020 r.","parameters_zh":[{"name":"芴"},{"name":"菲"},{"name":"蒽"},{"name":"荧蒽"},{"name":"芘"},{"name":"苯并（a）蒽"},{"name":"䓛"},{"name":"苯并(a)荧蒽"},{"name":"苯并（b）荧蒽"},{"name":"苯并（k）荧蒽"},{"name":"benzo(a,h)antracen"},{"name":"范围","range":"(0,001 – 2,0) μg/dm3"},{"name":"苯并（a）芘"},{"name":"范围","range":"(0,00006 – 2) μg/dm3"},{"name":"benzo(g,h,i)perylen indeno","range":"(1,2,3-c,d)piren"},{"name":"范围","range":"(0,0003 – 2) μg/dm3"}],"search_zh":"水、废水 高效液相色谱-荧光检测法（HPLC - FLD） 芴 菲 蒽 荧蒽 芘 苯并（a）蒽 䓛 苯并(a)荧蒽 苯并（b）荧蒽 苯并（k）荧蒽 范围 苯并（a）芘 范围 范围 PB-10/GD wydanie 2, 20 marca 2020 r.","test_object_zh":"水、废水","technique_zh":"高效液相色谱-荧光检测法（HPLC - FLD）"},{"_id":"6a5dc9bef1c10c8ce825eb5e","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie lotnych związków organicznych (VOC)","methodology_en":"Volatile organic compound (VOC) concentration","parameters":[{"name":"dichlorometan","range":"(1,0 – 100) μg/dm3"},{"name":"trichlorometan","range":"(0,50 – 100) μg/dm3"},{"name":"tetrachlorometan","range":"(1,0 – 100) μg/dm3"},{"name":"Zakres","range":"1,2-dichloroetan (1,0 – 100) μg/dm3"},{"name":"benzen","range":"(1,0 – 100) μg/dm3"},{"name":"toluen","range":"(1,0 – 100) μg/dm3"},{"name":"orto-ksylen","range":"(1,0 – 100) μg/dm3"},{"name":"(meta+para)-ksylen","range":"(1,0 – 100) μg/dm3"},{"name":"etylobenzen","range":"(1,0 – 100) μg/dm3"},{"name":"trichloroeten","range":"(1,0 – 100) μg/dm3"},{"name":"tetrachloroeten","range":"(1,0 – 100) μg/dm3"},{"name":"heksachlorobutadien","range":"(0,030 – 100) μg/dm3"},{"name":"naftalen","range":"(0,50 – 100) μg/dm3"}],"parameters_en":[{"name":"dichloromethane","range":"(1,0 – 100) μg/dm3"},{"name":"trichloromethane","range":"(0,50 – 100) μg/dm3"},{"name":"tetrachloromethane","range":"(1,0 – 100) μg/dm3"},{"name":"Range","range":"1,2-dichloroetan (1,0 – 100) μg/dm3"},{"name":"benzene","range":"(1,0 – 100) μg/dm3"},{"name":"toluene","range":"(1,0 – 100) μg/dm3"},{"name":"ortho-xylene","range":"(1,0 – 100) μg/dm3"},{"name":"(meta+para)-xylene","range":"(1,0 – 100) μg/dm3"},{"name":"ethylbenzene","range":"(1,0 – 100) μg/dm3"},{"name":"trichloroethene","range":"(1,0 – 100) μg/dm3"},{"name":"tetrachloroethene","range":"(1,0 – 100) μg/dm3"},{"name":"hexachlorobutadiene","range":"(0,030 – 100) μg/dm3"},{"name":"naphthalene","range":"(0,50 – 100) μg/dm3"}],"technique":"Metoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge & Trap) i detekcją spektrometrią mas (P&T GC-MS)","techniques":["Metoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge & Trap) i detekcją spektrometrią mas (P&T GC-MS)"],"technique_en":"Gas chromatography with purge and trap technique (Purge & Trap) and mass spectrometry detection (P&T GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych (VOC)\nZakres:\ndichlorometan (1,0 – 100) μg/dm3\ntrichlorometan (0,50 – 100) μg/dm3\ntetrachlorometan (1,0 – 100) μg/dm3\nZakres 1,2-dichloroetan (1,0 – 100) μg/dm3\nbenzen (1,0 – 100) μg/dm3\ntoluen (1,0 – 100) μg/dm3\norto-ksylen (1,0 – 100) μg/dm3\n(meta+para)-ksylen (1,0 – 100) μg/dm3\netylobenzen (1,0 – 100) μg/dm3\ntrichloroeten (1,0 – 100) μg/dm3\ntetrachloroeten (1,0 – 100) μg/dm3\nheksachlorobutadien (0,030 – 100) μg/dm3\nnaftalen (0,50 – 100) μg/dm3\nMetoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge & Trap) i detekcją spektrometrią mas (P&T GC-MS)","reference":"PN-EN ISO 15680:2008","norm_bases":["PN-EN ISO 15680:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie lotnych związków organicznych (VOC)\nZakres:\ndichlorometan (1,0 – 100) μg/dm3\ntrichlorometan (0,50 – 100) μg/dm3\ntetrachlorometan (1,0 – 100) μg/dm3\nZakres 1,2-dichloroetan (1,0 – 100) μg/dm3\nbenzen (1,0 – 100) μg/dm3\ntoluen (1,0 – 100) μg/dm3\norto-ksylen (1,0 – 100) μg/dm3\n(meta+para)-ksylen (1,0 – 100) μg/dm3\netylobenzen (1,0 – 100) μg/dm3\ntrichloroeten (1,0 – 100) μg/dm3\ntetrachloroeten (1,0 – 100) μg/dm3\nheksachlorobutadien (0,030 – 100) μg/dm3\nnaftalen (0,50 – 100) μg/dm3\nMetoda chromatografii gazowej z techniką wypłukiwania i wyłapywania (Purge & Trap) i detekcją spektrometrią mas (P&T GC-MS) PN-EN ISO 15680:2008 Woda Stezenie lotnych zwiazkow organicznych (VOC)\nZakres:\ndichlorometan (1,0 – 100) μg/dm3\ntrichlorometan (0,50 – 100) μg/dm3\ntetrachlorometan (1,0 – 100) μg/dm3\nZakres 1,2-dichloroetan (1,0 – 100) μg/dm3\nbenzen (1,0 – 100) μg/dm3\ntoluen (1,0 – 100) μg/dm3\norto-ksylen (1,0 – 100) μg/dm3\n(meta+para)-ksylen (1,0 – 100) μg/dm3\netylobenzen (1,0 – 100) μg/dm3\ntrichloroeten (1,0 – 100) μg/dm3\ntetrachloroeten (1,0 – 100) μg/dm3\nheksachlorobutadien (0,030 – 100) μg/dm3\nnaftalen (0,50 – 100) μg/dm3\nMetoda chromatografii gazowej z technika wyplukiwania i wylapywania (Purge & Trap) i detekcja spektrometria mas (P&T GC-MS) PN-EN ISO 15680:2008","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Volatile organic compound (VOC) concentration Gas chromatography with purge and trap technique (Purge & Trap) and mass spectrometry detection (P&T GC-MS) dichloromethane trichloromethane tetrachloromethane Range benzene toluene ortho-xylene (meta+para)-xylene ethylbenzene trichloroethene tetrachloroethene hexachlorobutadiene naphthalene PN-EN ISO 15680:2008","parameters_zh":[{"name":"二氯甲烷","range":"(1,0 – 100) μg/dm3"},{"name":"三氯甲烷","range":"(0,50 – 100) μg/dm3"},{"name":"四氯化碳","range":"(1,0 – 100) μg/dm3"},{"name":"范围","range":"1,2-dichloroetan (1,0 – 100) μg/dm3"},{"name":"苯","range":"(1,0 – 100) μg/dm3"},{"name":"甲苯","range":"(1,0 – 100) μg/dm3"},{"name":"orto-ksylen","range":"(1,0 – 100) μg/dm3"},{"name":"(meta+para)-ksylen","range":"(1,0 – 100) μg/dm3"},{"name":"乙苯","range":"(1,0 – 100) μg/dm3"},{"name":"三氯乙烯","range":"(1,0 – 100) μg/dm3"},{"name":"四氯乙烯","range":"(1,0 – 100) μg/dm3"},{"name":"六氯丁二烯","range":"(0,030 – 100) μg/dm3"},{"name":"萘","range":"(0,50 – 100) μg/dm3"}],"search_zh":"水 挥发性有机化合物（VOC）浓度 二氯甲烷 三氯甲烷 四氯化碳 范围 苯 甲苯 乙苯 三氯乙烯 四氯乙烯 六氯丁二烯 萘 PN-EN ISO 15680:2008","test_object_zh":"水","methodology_zh":"挥发性有机化合物（VOC）浓度"},{"_id":"6a5dc9bef1c10c8ce825eb5f","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/dm3 O2"},{"name":"Procent nasycenia"},{"name":"Zakres","range":"(3 – 200) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/dm3 O2"},{"name":"Percentage saturation"},{"name":"Range","range":"(3 – 200) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 20) mg/dm3 O2\nProcent nasycenia\nZakres (3 – 200) %\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 20) mg/dm3 O2\nProcent nasycenia\nZakres (3 – 200) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 20) mg/dm3 O2\nProcent nasycenia\nZakres (3 – 200) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Dissolved oxygen concentration Electrochemical method Range Percentage saturation Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/dm3 O2"},{"name":"Procent nasycenia"},{"name":"范围","range":"(3 – 200) %"}],"search_zh":"水 溶解氧浓度 电化学法 范围 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9bef1c10c8ce825eb60","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/dm3 CaCO3"}],"parameters_en":[{"name":"Range","range":"(5 – 1000) mg/dm3 CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/dm3 CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825eb61","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Substancje rozpuszczone","methodology_en":"Dissolved solids","parameters":[{"name":"Zakres","range":"(100 – 10000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(100 – 10000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje rozpuszczone\nZakres (100 – 10000) mg/dm3\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Substancje rozpuszczone\nZakres (100 – 10000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03 Woda Substancje rozpuszczone\nZakres (100 – 10000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(100 – 10000) mg/dm3"}],"search_zh":"水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水","methodology_zh":"溶解性固体"},{"_id":"6a5dc9bef1c10c8ce825eb62","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pestycydów","methodology_en":"Pesticide concentration","parameters":[{"name":"alfa-HCH","range":"(0,00017 – 0,020) μg/dm3"},{"name":"beta-HCH","range":"(0,00017 – 0,020) μg/dm3"},{"name":"gamma-H","range":"(0,00017 – 0,020) μg/dm3"},{"name":"delta-HCH","range":"(0,00017 – 0,020) μg/dm3"},{"name":"aldryna","range":"(0,00017 – 0,020) μg/dm3"},{"name":"dieldryna","range":"(0,00008 – 0,020) μg/dm3"},{"name":"endryna","range":"(0,00017 – 0,020) μg/dm3"},{"name":"izodryna","range":"(0,00008 – 0,020) μg/dm3"},{"name":"alfa-endosulfan"},{"name":"Zakres","range":"(0,00008 – 0,020) μg/dm3"},{"name":"beta-endosulfan","range":"(0,00008 – 0,020) μg/dm3"},{"name":"heksachlorobenzen","range":"(0,00017 – 0,020) μg/dm3"},{"name":"pentachlorobenzen","range":"(0,00017 – 0,020) μg/dm3"}],"parameters_en":[{"name":"alpha-HCH","range":"(0,00017 – 0,020) μg/dm3"},{"name":"beta-HCH","range":"(0,00017 – 0,020) μg/dm3"},{"name":"gamma-H","range":"(0,00017 – 0,020) μg/dm3"},{"name":"delta-HCH","range":"(0,00017 – 0,020) μg/dm3"},{"name":"aldrin","range":"(0,00017 – 0,020) μg/dm3"},{"name":"dieldrin","range":"(0,00008 – 0,020) μg/dm3"},{"name":"endrin","range":"(0,00017 – 0,020) μg/dm3"},{"name":"isodrin","range":"(0,00008 – 0,020) μg/dm3"},{"name":"alpha-endosulfan"},{"name":"Range","range":"(0,00008 – 0,020) μg/dm3"},{"name":"beta-endosulfan","range":"(0,00008 – 0,020) μg/dm3"},{"name":"hexachlorobenzene","range":"(0,00017 – 0,020) μg/dm3"},{"name":"pentachlorobenzene","range":"(0,00017 – 0,020) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie pestycydów\nZakres:\nalfa-HCH (0,00017 – 0,020) μg/dm3\nbeta-HCH (0,00017 – 0,020) μg/dm3\ngamma-H (0,00017 – 0,020) μg/dm3\ndelta-HCH (0,00017 – 0,020) μg/dm3\naldryna (0,00017 – 0,020) μg/dm3\ndieldryna (0,00008 – 0,020) μg/dm3\nendryna (0,00017 – 0,020) μg/dm3\nizodryna (0,00008 – 0,020) μg/dm3\nalfa-endosulfan\nZakres (0,00008 – 0,020) μg/dm3\nbeta-endosulfan (0,00008 – 0,020) μg/dm3\nheksachlorobenzen (0,00017 – 0,020) μg/dm3\npentachlorobenzen (0,00017 – 0,020) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PB-64/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-64/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pestycydów\nZakres:\nalfa-HCH (0,00017 – 0,020) μg/dm3\nbeta-HCH (0,00017 – 0,020) μg/dm3\ngamma-H (0,00017 – 0,020) μg/dm3\ndelta-HCH (0,00017 – 0,020) μg/dm3\naldryna (0,00017 – 0,020) μg/dm3\ndieldryna (0,00008 – 0,020) μg/dm3\nendryna (0,00017 – 0,020) μg/dm3\nizodryna (0,00008 – 0,020) μg/dm3\nalfa-endosulfan\nZakres (0,00008 – 0,020) μg/dm3\nbeta-endosulfan (0,00008 – 0,020) μg/dm3\nheksachlorobenzen (0,00017 – 0,020) μg/dm3\npentachlorobenzen (0,00017 – 0,020) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PB-64/GD wydanie 2, 20 marca 2020 r. Woda Stezenie pestycydow\nZakres:\nalfa-HCH (0,00017 – 0,020) μg/dm3\nbeta-HCH (0,00017 – 0,020) μg/dm3\ngamma-H (0,00017 – 0,020) μg/dm3\ndelta-HCH (0,00017 – 0,020) μg/dm3\naldryna (0,00017 – 0,020) μg/dm3\ndieldryna (0,00008 – 0,020) μg/dm3\nendryna (0,00017 – 0,020) μg/dm3\nizodryna (0,00008 – 0,020) μg/dm3\nalfa-endosulfan\nZakres (0,00008 – 0,020) μg/dm3\nbeta-endosulfan (0,00008 – 0,020) μg/dm3\nheksachlorobenzen (0,00017 – 0,020) μg/dm3\npentachlorobenzen (0,00017 – 0,020) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PB-64/GD wydanie 2, 20 marca 2020 r.","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Pesticide concentration Gas chromatography with electron capture detection (GC-ECD) alpha-HCH beta-HCH gamma-H delta-HCH aldrin dieldrin endrin isodrin alpha-endosulfan Range beta-endosulfan hexachlorobenzene pentachlorobenzene PB-64/GD wydanie 2, 20 marca 2020 r.","methodology_zh":"农药浓度","parameters_zh":[{"name":"α-六六六","range":"(0,00017 – 0,020) μg/dm3"},{"name":"β-六六六","range":"(0,00017 – 0,020) μg/dm3"},{"name":"gamma-H","range":"(0,00017 – 0,020) μg/dm3"},{"name":"δ-六六六","range":"(0,00017 – 0,020) μg/dm3"},{"name":"艾氏剂","range":"(0,00017 – 0,020) μg/dm3"},{"name":"狄氏剂","range":"(0,00008 – 0,020) μg/dm3"},{"name":"异狄氏剂","range":"(0,00017 – 0,020) μg/dm3"},{"name":"异艾氏剂","range":"(0,00008 – 0,020) μg/dm3"},{"name":"alfa-endosulfan"},{"name":"范围","range":"(0,00008 – 0,020) μg/dm3"},{"name":"beta-endosulfan","range":"(0,00008 – 0,020) μg/dm3"},{"name":"六氯苯","range":"(0,00017 – 0,020) μg/dm3"},{"name":"五氯苯","range":"(0,00017 – 0,020) μg/dm3"}],"search_zh":"水 农药浓度 气相色谱-电子捕获检测法（GC-ECD） α-六六六 β-六六六 δ-六六六 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 范围 六氯苯 五氯苯 PB-64/GD wydanie 2, 20 marca 2020 r.","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825eb63","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pestycydów","methodology_en":"Pesticide concentration","parameters":[{"name":"alfa-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"beta-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"gamma-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"delta-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer p,p-DDT"},{"name":"Zakres","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer o,p-DDT","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer p,p-DDD","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer p,p-DDE","range":"(0,001 – 0,20) μg/dm3"},{"name":"aldryna","range":"(0,001 – 0,20) μg/dm3"},{"name":"dieldryna","range":"(0,0005 – 0,20) μg/dm3"},{"name":"endryna","range":"(0,001 – 0,20) μg/dm3"},{"name":"izodryna","range":"(0,0005 – 0,20) μg/dm3"},{"name":"alfa-endosulfan","range":"(0,0005 – 0,20) μg/dm3"},{"name":"beta-endosulfan","range":"(0,0005 – 0,20) μg/dm3"},{"name":"heksachlorobenzen","range":"(0,001 – 0,20) μg/dm3"},{"name":"pentachlorobenzen","range":"(0,001 – 0,20) μg/dm3"},{"name":"trifluralina","range":"(0,010 – 0,20) μg/dm3"},{"name":"1,2,3-trichlorobenzen","range":"(0,005 – 0,20) μg/dm3"},{"name":"1,2,4-trichlorobenzen","range":"(0,005 – 0,20) μg/dm3"},{"name":"1,3,5-trichlorobenzen","range":"(0,005 – 0,20) μg/dm3"},{"name":"alachlor","range":"(0,030 – 0,30) μg/dm3"}],"parameters_en":[{"name":"alpha-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"beta-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"gamma-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"delta-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"p,p-DDT isomer"},{"name":"Range","range":"(0,001 – 0,20) μg/dm3"},{"name":"o,p-DDT isomer","range":"(0,001 – 0,20) μg/dm3"},{"name":"p,p-DDD isomer","range":"(0,001 – 0,20) μg/dm3"},{"name":"p,p-DDE isomer","range":"(0,001 – 0,20) μg/dm3"},{"name":"aldrin","range":"(0,001 – 0,20) μg/dm3"},{"name":"dieldrin","range":"(0,0005 – 0,20) μg/dm3"},{"name":"endrin","range":"(0,001 – 0,20) μg/dm3"},{"name":"isodrin","range":"(0,0005 – 0,20) μg/dm3"},{"name":"alpha-endosulfan","range":"(0,0005 – 0,20) μg/dm3"},{"name":"beta-endosulfan","range":"(0,0005 – 0,20) μg/dm3"},{"name":"hexachlorobenzene","range":"(0,001 – 0,20) μg/dm3"},{"name":"pentachlorobenzene","range":"(0,001 – 0,20) μg/dm3"},{"name":"trifluralin","range":"(0,010 – 0,20) μg/dm3"},{"name":"1,2,3-trichlorobenzene","range":"(0,005 – 0,20) μg/dm3"},{"name":"1,2,4-trichlorobenzene","range":"(0,005 – 0,20) μg/dm3"},{"name":"1,3,5-trichlorobenzene","range":"(0,005 – 0,20) μg/dm3"},{"name":"alachlor","range":"(0,030 – 0,30) μg/dm3"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie pestycydów\nZakres:\nalfa-HCH (0,001 – 0,20) μg/dm3\nbeta-HCH (0,001 – 0,20) μg/dm3\ngamma-HCH (0,001 – 0,20) μg/dm3\ndelta-HCH (0,001 – 0,20) μg/dm3\nizomer p,p-DDT\nZakres (0,001 – 0,20) μg/dm3\nizomer o,p-DDT (0,001 – 0,20) μg/dm3\nizomer p,p-DDD (0,001 – 0,20) μg/dm3\nizomer p,p-DDE (0,001 – 0,20) μg/dm3\naldryna (0,001 – 0,20) μg/dm3\ndieldryna (0,0005 – 0,20) μg/dm3\nendryna (0,001 – 0,20) μg/dm3\nizodryna (0,0005 – 0,20) μg/dm3\nalfa-endosulfan (0,0005 – 0,20) μg/dm3\nbeta-endosulfan (0,0005 – 0,20) μg/dm3\nheksachlorobenzen (0,001 – 0,20) μg/dm3\npentachlorobenzen (0,001 – 0,20) μg/dm3\ntrifluralina (0,010 – 0,20) μg/dm3\n1,2,3-trichlorobenzen (0,005 – 0,20) μg/dm3\n1,2,4-trichlorobenzen (0,005 – 0,20) μg/dm3\n1,3,5-trichlorobenzen (0,005 – 0,20) μg/dm3\nalachlor (0,030 – 0,30) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pestycydów\nZakres:\nalfa-HCH (0,001 – 0,20) μg/dm3\nbeta-HCH (0,001 – 0,20) μg/dm3\ngamma-HCH (0,001 – 0,20) μg/dm3\ndelta-HCH (0,001 – 0,20) μg/dm3\nizomer p,p-DDT\nZakres (0,001 – 0,20) μg/dm3\nizomer o,p-DDT (0,001 – 0,20) μg/dm3\nizomer p,p-DDD (0,001 – 0,20) μg/dm3\nizomer p,p-DDE (0,001 – 0,20) μg/dm3\naldryna (0,001 – 0,20) μg/dm3\ndieldryna (0,0005 – 0,20) μg/dm3\nendryna (0,001 – 0,20) μg/dm3\nizodryna (0,0005 – 0,20) μg/dm3\nalfa-endosulfan (0,0005 – 0,20) μg/dm3\nbeta-endosulfan (0,0005 – 0,20) μg/dm3\nheksachlorobenzen (0,001 – 0,20) μg/dm3\npentachlorobenzen (0,001 – 0,20) μg/dm3\ntrifluralina (0,010 – 0,20) μg/dm3\n1,2,3-trichlorobenzen (0,005 – 0,20) μg/dm3\n1,2,4-trichlorobenzen (0,005 – 0,20) μg/dm3\n1,3,5-trichlorobenzen (0,005 – 0,20) μg/dm3\nalachlor (0,030 – 0,30) μg/dm3\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda Stezenie pestycydow\nZakres:\nalfa-HCH (0,001 – 0,20) μg/dm3\nbeta-HCH (0,001 – 0,20) μg/dm3\ngamma-HCH (0,001 – 0,20) μg/dm3\ndelta-HCH (0,001 – 0,20) μg/dm3\nizomer p,p-DDT\nZakres (0,001 – 0,20) μg/dm3\nizomer o,p-DDT (0,001 – 0,20) μg/dm3\nizomer p,p-DDD (0,001 – 0,20) μg/dm3\nizomer p,p-DDE (0,001 – 0,20) μg/dm3\naldryna (0,001 – 0,20) μg/dm3\ndieldryna (0,0005 – 0,20) μg/dm3\nendryna (0,001 – 0,20) μg/dm3\nizodryna (0,0005 – 0,20) μg/dm3\nalfa-endosulfan (0,0005 – 0,20) μg/dm3\nbeta-endosulfan (0,0005 – 0,20) μg/dm3\nheksachlorobenzen (0,001 – 0,20) μg/dm3\npentachlorobenzen (0,001 – 0,20) μg/dm3\ntrifluralina (0,010 – 0,20) μg/dm3\n1,2,3-trichlorobenzen (0,005 – 0,20) μg/dm3\n1,2,4-trichlorobenzen (0,005 – 0,20) μg/dm3\n1,3,5-trichlorobenzen (0,005 – 0,20) μg/dm3\nalachlor (0,030 – 0,30) μg/dm3\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Pesticide concentration Gas chromatography with electron capture detection (GC-ECD) alpha-HCH beta-HCH gamma-HCH delta-HCH p,p-DDT isomer Range o,p-DDT isomer p,p-DDD isomer p,p-DDE isomer aldrin dieldrin endrin isodrin alpha-endosulfan beta-endosulfan hexachlorobenzene pentachlorobenzene trifluralin 1,2,3-trichlorobenzene 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene alachlor PN-EN ISO 6468:2002","methodology_zh":"农药浓度","parameters_zh":[{"name":"α-六六六","range":"(0,001 – 0,20) μg/dm3"},{"name":"β-六六六","range":"(0,001 – 0,20) μg/dm3"},{"name":"gamma-HCH","range":"(0,001 – 0,20) μg/dm3"},{"name":"δ-六六六","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer p,p-DDT"},{"name":"范围","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer o,p-DDT","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer p,p-DDD","range":"(0,001 – 0,20) μg/dm3"},{"name":"izomer p,p-DDE","range":"(0,001 – 0,20) μg/dm3"},{"name":"艾氏剂","range":"(0,001 – 0,20) μg/dm3"},{"name":"狄氏剂","range":"(0,0005 – 0,20) μg/dm3"},{"name":"异狄氏剂","range":"(0,001 – 0,20) μg/dm3"},{"name":"异艾氏剂","range":"(0,0005 – 0,20) μg/dm3"},{"name":"alfa-endosulfan","range":"(0,0005 – 0,20) μg/dm3"},{"name":"beta-endosulfan","range":"(0,0005 – 0,20) μg/dm3"},{"name":"六氯苯","range":"(0,001 – 0,20) μg/dm3"},{"name":"五氯苯","range":"(0,001 – 0,20) μg/dm3"},{"name":"氟乐灵","range":"(0,010 – 0,20) μg/dm3"},{"name":"1,2,3-三氯苯","range":"(0,005 – 0,20) μg/dm3"},{"name":"1,2,4-三氯苯","range":"(0,005 – 0,20) μg/dm3"},{"name":"1,3,5-三氯苯","range":"(0,005 – 0,20) μg/dm3"},{"name":"alachlor","range":"(0,030 – 0,30) μg/dm3"}],"search_zh":"水 农药浓度 气相色谱-电子捕获检测法（GC-ECD） α-六六六 β-六六六 δ-六六六 范围 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 六氯苯 五氯苯 氟乐灵 1,2,3-三氯苯 1,2,4-三氯苯 1,3,5-三氯苯 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825eb64","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"( 10 – 1000) mg/dm3 CaCO3"}],"parameters_en":[{"name":"Range","range":"( 10 – 1000) mg/dm3 CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres ( 10 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres ( 10 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres ( 10 – 1000) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"( 10 – 1000) mg/dm3 CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825eb65","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,025 – 5,0 )mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,025 – 5,0 )mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,025 – 5,0 )mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1: 2002","norm_bases":["PN-ISO 7150-1: 2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu amonowego\nZakres (0,025 – 5,0 )mg/dm3\nMetoda spektrofotometryczna PN-ISO 7150-1: 2002 Woda Stezenie azotu amonowego\nZakres (0,025 – 5,0 )mg/dm3\nMetoda spektrofotometryczna PN-ISO 7150-1: 2002","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1: 2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 5,0 )mg/dm3"}],"search_zh":"水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1: 2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825eb66","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego (z obliczeń)","methodology_en":"Ammonium ion concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-ISO 7150-1: 2002","norm_bases":["PN-ISO 7150-1: 2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego (z obliczeń) PN-ISO 7150-1: 2002 Woda Stezenie jonu amonowego (z obliczen) PN-ISO 7150-1: 2002","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Ammonium ion concentration (calculated) PN-ISO 7150-1: 2002","search_zh":"水 铵离子浓度（由计算得出） PN-ISO 7150-1: 2002","test_object_zh":"水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb67","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie substancji rozpuszczonych ogólnych","methodology_en":"Total dissolved solids concentration","parameters":[{"name":"Zakres","range":"(100 – 10000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(100 – 10000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji rozpuszczonych ogólnych\nZakres (100 – 10000) mg/dm3\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie substancji rozpuszczonych ogólnych\nZakres (100 – 10000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03 Woda Stezenie substancji rozpuszczonych ogolnych\nZakres (100 – 10000) mg/dm3\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total dissolved solids concentration Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(100 – 10000) mg/dm3"}],"search_zh":"水 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825eb68","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"F","range":"(0,10 – 10) mg/dm3"},{"name":"Cl","range":"(1,0 – 100) mg/dm3"},{"name":"NO3","range":"(1,0 – 100) mg/dm3"},{"name":"SO42","range":"(1,0 – 100) mg/dm3"}],"parameters_en":[{"name":"F","range":"(0,10 – 10) mg/dm3"},{"name":"Cl","range":"(1,0 – 100) mg/dm3"},{"name":"NO3","range":"(1,0 – 100) mg/dm3"},{"name":"SO42","range":"(1,0 – 100) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nF (0,10 – 10) mg/dm3\nCl (1,0 – 100) mg/dm3\nNO3 (1,0 – 100) mg/dm3\nSO42 (1,0 – 100) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów\nZakres:\nF (0,10 – 10) mg/dm3\nCl (1,0 – 100) mg/dm3\nNO3 (1,0 – 100) mg/dm3\nSO42 (1,0 – 100) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie anionow\nZakres:\nF (0,10 – 10) mg/dm3\nCl (1,0 – 100) mg/dm3\nNO3 (1,0 – 100) mg/dm3\nSO42 (1,0 – 100) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) F Cl NO3 SO42 PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825eb69","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu azotanowego (z obliczeń)","methodology_en":"Nitrate nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"水 硝酸盐氮浓度（由计算得出） PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb6a","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie sumy azotu azotanowego i azotu azotynowego","methodology_en":"Concentration of the sum of nitrate nitrogen and nitrite nitrogen","parameters":[{"name":"Zakres","range":"(0,020 – 50) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,020 – 50) mg/dm3"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie sumy azotu azotanowego i azotu azotynowego\nZakres (0,020 – 50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie sumy azotu azotanowego i azotu azotynowego\nZakres (0,020 – 50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie sumy azotu azotanowego i azotu azotynowego\nZakres (0,020 – 50) mg/dm3\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Concentration of the sum of nitrate nitrogen and nitrite nitrogen Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","parameters_zh":[{"name":"范围","range":"(0,020 – 50) mg/dm3"}],"search_zh":"水、废水 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb6b","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego (z obliczeń)","methodology_en":"Nitrate nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego (z obliczeń)","reference":"PB-66/GD wydanie 2, 20 marca 2020 r.","norm_bases":["PB-66/GD wydanie 2, 20 marca 2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego (z obliczeń) PB-66/GD wydanie 2, 20 marca 2020 r. Woda, scieki Stezenie azotu azotanowego (z obliczen) PB-66/GD wydanie 2, 20 marca 2020 r.","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrate nitrogen concentration (calculated) PB-66/GD wydanie 2, 20 marca 2020 r.","search_zh":"水、废水 硝酸盐氮浓度（由计算得出） PB-66/GD wydanie 2, 20 marca 2020 r.","test_object_zh":"水、废水","methodology_zh":"硝酸盐氮浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb6c","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,0020 – 2,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,0020 – 2,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 2,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0020 – 2,0) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0020 – 2,0) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 2,0) mg/dm3"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb6d","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotynów (z obliczeń)","methodology_en":"Nitrite concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotynów (z obliczeń) PN-EN 26777:1999 Woda, scieki Stezenie azotynow (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite concentration (calculated) PN-EN 26777:1999","search_zh":"水、废水 亚硝酸盐浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"水、废水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825eb6e","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego Kjeldahla","methodology_en":"Total Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu ogolnego Kjeldahla\nZakres (0,50 – 1000) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/dm3"}],"search_zh":"水、废水 凯氏总氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"凯氏总氮浓度"},{"_id":"6a5dc9bef1c10c8ce825eb6f","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","norm_bases":["PB-26/CLB wydanie 1 z dnia 16.01.2026 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wydanie 1 z dnia 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb70","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/dm3"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (0,10 – 50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11905-1:2001","norm_bases":["PN-EN ISO 11905-1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (0,10 – 50) mg/dm3\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11905-1:2001 Woda, scieki Stezenie azotu ogolnego\nZakres (0,10 – 50) mg/dm3\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11905-1:2001","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11905-1:2001","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/dm3"}],"search_zh":"水、废水 总氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11905-1:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb71","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforanów","methodology_en":"Phosphate concentration","parameters":[{"name":"Zakres","range":"(0,020 – 16,0) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,020 – 16,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforanów\nZakres (0,020 – 16,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres (0,020 – 16,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010 Woda, scieki Stezenie fosforanow\nZakres (0,020 – 16,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,020 – 16,0) mg/dm3"}],"search_zh":"水、废水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a5dc9bef1c10c8ce825eb72","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu (z obliczeń)","methodology_en":"Phosphorus concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu (z obliczeń)","reference":"PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu (z obliczeń) PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010 Woda, scieki Stezenie fosforu (z obliczen) PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phosphorus concentration (calculated) PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006 pkt 4 + Ap1:2010 + Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb73","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,007– 5,20) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(0,007– 5,20) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,007– 5,20) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,007– 5,20) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,007– 5,20) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,007– 5,20) mg/dm3"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb74","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforanów (z obliczeń)","methodology_en":"Phosphate concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforanów (z obliczeń)","reference":"PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforanów (z obliczeń) PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforanow (z obliczen) PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phosphate concentration (calculated) PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006 pkt 7, 8 +Ap1:2010+Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb75","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","methodology_en":"Chemical oxygen demand - COD","parameters":[{"name":"Zakres","range":"(5 – 4000) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(5 – 4000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 4000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 4000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 4000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand - COD Spectrophotometric method Range PN-ISO 15705:2005","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(5 – 4000) mg/dm3 O2"}],"search_zh":"水、废水 化学需氧量 ChZT（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb76","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 20) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/dm3 O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9bef1c10c8ce825eb77","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,5 – 6) mg/dm3 O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bef1c10c8ce825eb78","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/dm3 O2"}],"parameters_en":[{"name":"Range","range":"(1 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/dm3 O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bef1c10c8ce825eb79","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/dm3"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/dm3"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb7a","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","methodology_en":"Sampling for chemical and physical testing Temperature","parameters":[{"name":"Zakres","range":"(0 – 30) °C"}],"parameters_en":[{"name":"Range","range":"(0 – 30) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0 – 30) °C","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2 | PN-77/C-04584","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12","PN-ISO 5667-9:2005","PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0 – 30) °C PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0 – 30) °C PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wylaczeniem pkt. 5.2, 6.2 | PN-77/C-04584","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature Range PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(0 – 30) °C"}],"search_zh":"水 化学和物理检测采样 温度 范围 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-9:2005 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2, 6.2 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a5dc9bef1c10c8ce825eb7b","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0 – 30) °C"}],"parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0 – 30) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0 – 30) °C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0 – 30) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0 – 30) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0 – 30) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9bef1c10c8ce825eb7c","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb7d","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(84 – 20 000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(84 – 20 000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 – 20 000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (84 – 20 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (84 – 20 000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84 – 20 000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eb7e","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 20) mg/l O2"},{"name":"Procent nasycenia"},{"name":"Zakres","range":"(3 – 200) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20) mg/l O2"},{"name":"Percentage saturation"},{"name":"Range","range":"(3 – 200) %"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 20) mg/l O2\nProcent nasycenia\nZakres (3 – 200) %\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 20) mg/l O2\nProcent nasycenia\nZakres (3 – 200) %\nMetoda optyczna ISO 17289:2014 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres:\nZakres (0,5 – 20) mg/l O2\nProcent nasycenia\nZakres (3 – 200) %\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Optical method Range Percentage saturation Range ISO 17289:2014","parameters_zh":[{"name":"范围","range":"(0,5 – 20) mg/l O2"},{"name":"Procent nasycenia"},{"name":"范围","range":"(3 – 200) %"}],"search_zh":"水、废水 溶解氧浓度 光学法 范围 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9bef1c10c8ce825eb7f","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5dc9bef1c10c8ce825eb80","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(25 – 135) dB"}],"parameters_en":[{"name":"Range","range":"(25 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 135) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9bef1c10c8ce825eb81","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 7.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9bef1c10c8ce825eb82","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment - noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters":[{"name":"Zakres","range":"(30 – 135) dB"}],"parameters_en":[{"name":"Range","range":"(30 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (30 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (30 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697) Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (30 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wylaczeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","categories":["environment"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","parameters_zh":[{"name":"范围","range":"(30 – 135) dB"}],"search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5dc9bef1c10c8ce825eb83","lab_id":"69ad52a3de79e566650fb3fe","country":"PL","accr_number":"AB 794","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment - noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697) Srodowisko ogolne - halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wylaczeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment - noise from roads, railway lines, tram lines A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. 2011 Nr 140, poz. 824) z wyłączeniem punktu H (Dz.U. 2011 Nr 288, poz. 1697)","test_object_zh":"一般环境 — 来自道路、铁路线、有轨电车线的噪声"}],"has_pdf":true}