{"lab":{"_id":"69ad52a3de79e566650fb3f6","accr_number":"AB 788","country":"PL","accr_body":"PCA","address":"POLSKIEJ AKADEMII NAUK, LABORATORIUM EKSPERTYZ RADIOMETRYCZNYCH, ul. Radzikowskiego 152, 31-342 Kraków","categories":["environment","water","construction","materials"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":11,"name":"INSTYTUT FIZYKI JĄDROWEJ im. Henryka Niewodniczańskiego","parse_status":"parsed","parse_version":2,"pdf_files":["AB_788.pdf"],"scope_summary":"","search_text":"instytut fizyki jądrowej im. henryka niewodniczańskiego polskiej akademii nauk, laboratorium ekspertyz radiometrycznych, ul. radzikowskiego 152, 31-342 kraków materials construction water environment other","status":"active","updated_at":"2026-03-08T14:51:40.516Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:40.516Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20788,podmiot.html","fields_of_testing":[{"codes":"O/5, O/9, O/28, O/29, O/30, O/31, O/32","pl":"Badania radiochemiczne i promieniowania – w tym nuklearne wyrobów budowlanych, materiałów budowlanych, powietrza, wody, woda do spożycia przez ludzi, gleby, odpadów, osadów, ścieków","en":"Radiochemical tests and tests of radiation – including nuclear radiation in the buildings products, building materials, air, water, drinking water, soil, waste, sewage"}],"issue":{"no":"20","date":"12.12.2024"},"parse_date":"2026-07-20T20:42:15.142Z","parse_source":"script-pdfplumber","map_coord":[50.089353,19.889139],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":10,"water":7,"construction":6,"materials":6},"category_scores":{"environment":3.45,"water":1.69,"construction":1.24,"materials":1.24},"has_zh":true},"methods":[{"_id":"6a5e8827b979cd801f4834b1","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","test_object_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"40K"},{"name":"Zakres","range":"(3,7 – 16 000) Bq/kg"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"40K"},{"name":"Range","range":"(3,7 – 16 000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 40K\nZakres (3,7 – 16 000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"KUTh wydanie 8 z dnia 08.09.2021","norm_bases":["KUTh wydanie 8 z dnia 08.09.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 40K\nZakres (3,7 – 16 000) Bq/kg\nMetoda spektrometrii promieniowania gamma KUTh wydanie 8 z dnia 08.09.2021 Materialy i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 40K\nZakres (3,7 – 16 000) Bq/kg\nMetoda spektrometrii promieniowania gamma KUTh wydanie 8 z dnia 08.09.2021","categories":["environment","water","materials","construction"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Radionuclide activity concentration Gamma-ray spectrometry method Radionuclide activity concentration Range KUTh wydanie 8 z dnia 08.09.2021","parameters_zh":[{"name":"放射性核素活度浓度","range":"40K"},{"name":"范围","range":"(3,7 – 16 000) Bq/kg"}],"search_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02， 放射性核素活度浓度 γ 能谱法 放射性核素活度浓度 范围 KUTh wydanie 8 z dnia 08.09.2021","methodology_zh":"放射性核素活度浓度","technique_zh":"γ 能谱法","test_object_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02，"},{"_id":"6a5e8827b979cd801f4834b2","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","test_object_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"214Bi"},{"name":"Zakres","range":"(1,2 – 5 000) Bq/kg"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"214Bi"},{"name":"Range","range":"(1,2 – 5 000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 214Bi\nZakres (1,2 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"KUTh wydanie 8 z dnia 08.09.2021","norm_bases":["KUTh wydanie 8 z dnia 08.09.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 214Bi\nZakres (1,2 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma KUTh wydanie 8 z dnia 08.09.2021 Materialy i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 214Bi\nZakres (1,2 – 5 000) Bq/kg\nMetoda spektrometrii promieniowania gamma KUTh wydanie 8 z dnia 08.09.2021","categories":["environment","water","materials","construction"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Radionuclide activity concentration Gamma-ray spectrometry method Radionuclide activity concentration Range KUTh wydanie 8 z dnia 08.09.2021","parameters_zh":[{"name":"放射性核素活度浓度","range":"214Bi"},{"name":"范围","range":"(1,2 – 5 000) Bq/kg"}],"search_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02， 放射性核素活度浓度 γ 能谱法 放射性核素活度浓度 范围 KUTh wydanie 8 z dnia 08.09.2021","methodology_zh":"放射性核素活度浓度","technique_zh":"γ 能谱法","test_object_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02，"},{"_id":"6a5e8827b979cd801f4834b3","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","test_object_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"208Tl"},{"name":"Zakres","range":"(1,1 – 3 300) Bq/kg"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"208Tl"},{"name":"Range","range":"(1,1 – 3 300) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"technique_en":"Gamma-ray spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 208Tl\nZakres (1,1 – 3 300) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"KUTh wydanie 8 z dnia 08.09.2021","norm_bases":["KUTh wydanie 8 z dnia 08.09.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 208Tl\nZakres (1,1 – 3 300) Bq/kg\nMetoda spektrometrii promieniowania gamma KUTh wydanie 8 z dnia 08.09.2021 Materialy i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 208Tl\nZakres (1,1 – 3 300) Bq/kg\nMetoda spektrometrii promieniowania gamma KUTh wydanie 8 z dnia 08.09.2021","categories":["environment","water","materials","construction"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Radionuclide activity concentration Gamma-ray spectrometry method Radionuclide activity concentration Range KUTh wydanie 8 z dnia 08.09.2021","parameters_zh":[{"name":"放射性核素活度浓度","range":"208Tl"},{"name":"范围","range":"(1,1 – 3 300) Bq/kg"}],"search_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02， 放射性核素活度浓度 γ 能谱法 放射性核素活度浓度 范围 KUTh wydanie 8 z dnia 08.09.2021","methodology_zh":"放射性核素活度浓度","technique_zh":"γ 能谱法","test_object_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02，"},{"_id":"6a5e8827b979cd801f4834b4","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","test_object_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"226Ra"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"226Ra"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 226Ra\n(z obliczeń)","reference":"KUTh wydanie 8 z dnia 08.09.2021","norm_bases":["KUTh wydanie 8 z dnia 08.09.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 226Ra\n(z obliczeń) KUTh wydanie 8 z dnia 08.09.2021 Materialy i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 226Ra\n(z obliczen) KUTh wydanie 8 z dnia 08.09.2021","categories":["environment","water","materials","construction"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Radionuclide activity concentration Radionuclide activity concentration (calculated) KUTh wydanie 8 z dnia 08.09.2021","parameters_zh":[{"name":"放射性核素活度浓度","range":"226Ra"},{"name":"（计算得出）"}],"search_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02， 放射性核素活度浓度 放射性核素活度浓度 （计算得出） KUTh wydanie 8 z dnia 08.09.2021","methodology_zh":"放射性核素活度浓度","test_object_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02，"},{"_id":"6a5e8827b979cd801f4834b5","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","test_object_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","methodology":"Stężenie aktywności radionuklidu","methodology_en":"Radionuclide activity concentration","parameters":[{"name":"Stężenie aktywności radionuklidu","range":"232Th"},{"name":"(z obliczeń)"}],"parameters_en":[{"name":"Radionuclide activity concentration","range":"232Th"},{"name":"(calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 232Th\n(z obliczeń)","reference":"KUTh wydanie 8 z dnia 08.09.2021","norm_bases":["KUTh wydanie 8 z dnia 08.09.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stężenie aktywności radionuklidu\nZakres:\nStężenie aktywności radionuklidu 232Th\n(z obliczeń) KUTh wydanie 8 z dnia 08.09.2021 Materialy i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Stezenie aktywnosci radionuklidu\nZakres:\nStezenie aktywnosci radionuklidu 232Th\n(z obliczen) KUTh wydanie 8 z dnia 08.09.2021","categories":["environment","water","materials","construction"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Radionuclide activity concentration Radionuclide activity concentration (calculated) KUTh wydanie 8 z dnia 08.09.2021","parameters_zh":[{"name":"放射性核素活度浓度","range":"232Th"},{"name":"（计算得出）"}],"search_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02， 放射性核素活度浓度 放射性核素活度浓度 （计算得出） KUTh wydanie 8 z dnia 08.09.2021","methodology_zh":"放射性核素活度浓度","test_object_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02，"},{"_id":"6a5e8827b979cd801f4834b6","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","test_object_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02,","methodology":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","methodology_en":"Activity concentration index I (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","reference":"KUTh wydanie 8 z dnia 08.09.2021","norm_bases":["KUTh wydanie 8 z dnia 08.09.2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Wskaźnik stężenia promieniotwórczego I (z obliczeń) KUTh wydanie 8 z dnia 08.09.2021 Materialy i wyroby budowlane, Gleba, Osady, Odpady kod: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Wskaznik stezenia promieniotworczego I (z obliczen) KUTh wydanie 8 z dnia 08.09.2021","categories":["environment","water","materials","construction"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials and products, Soil, Sediments, Waste code: 01 01 01, 01 01 02, 01 01 80, 01 03 08, 01 03 99, 01 04 08, 01 04 09, 01 04 10, 01 04 13, 02 01 01, 02 01 07, 02 02 04, 02 03 05, 03 01 01, 03 01 05, 03 01 99, 05 01 15*, 06 09 80, 06 09 81, 10 01 01, 10 01 02, 10 01 04*, 10 01 80, 10 01 99, 10 02 01, 10 02 99, 17 01 01, 17 01 02, 17 01 03, 17 01 81, 17 01 82, 17 08 02, Activity concentration index I (calculated) KUTh wydanie 8 z dnia 08.09.2021","methodology_zh":"放射性浓度指数 I（计算得出）","search_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02， 放射性浓度指数 I（计算得出） KUTh wydanie 8 z dnia 08.09.2021","test_object_zh":"建筑材料与制品、土壤、污泥、废物，代码：01 01 01、01 01 02、01 01 80、01 03 08、01 03 99、01 04 08、01 04 09、01 04 10、01 04 13、02 01 01、02 01 07、02 02 04、02 03 05、03 01 01、03 01 05、03 01 99、05 01 15*、06 09 80、06 09 81、10 01 01、10 01 02、10 01 04*、10 01 80、10 01 99、10 02 01、10 02 99、17 01 01、17 01 02、17 01 03、17 01 81、17 01 82、17 08 02，"},{"_id":"6a5e8827b979cd801f4834b7","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Woda, ścieki, woda do spożycia przez ludzi","test_object_en":"Water, wastewater, water intended for human consumption","methodology":"Stężenie izotopu radonu 222Rn","methodology_en":"Concentration of the radon isotope 222Rn","parameters":[{"name":"Zakres","range":"1 Bq/dm3 – 4,5 kBq/dm3"}],"parameters_en":[{"name":"Range","range":"1 Bq/dm3 – 4,5 kBq/dm3"}],"technique":"Metoda spektrometrii promieniowania alfa","techniques":["Metoda spektrometrii promieniowania alfa"],"technique_en":"Alpha spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn\nZakres 1 Bq/dm3 – 4,5 kBq/dm3\nMetoda spektrometrii promieniowania alfa","reference":"RW wydanie 9 z dnia 22.08.2024","norm_bases":["RW wydanie 9 z dnia 22.08.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki, woda do spożycia przez ludzi Stężenie izotopu radonu 222Rn\nZakres 1 Bq/dm3 – 4,5 kBq/dm3\nMetoda spektrometrii promieniowania alfa RW wydanie 9 z dnia 22.08.2024 Woda, scieki, woda do spozycia przez ludzi Stezenie izotopu radonu 222Rn\nZakres 1 Bq/dm3 – 4,5 kBq/dm3\nMetoda spektrometrii promieniowania alfa RW wydanie 9 z dnia 22.08.2024","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater, water intended for human consumption Concentration of the radon isotope 222Rn Alpha spectrometry method Range RW wydanie 9 z dnia 22.08.2024","parameters_zh":[{"name":"范围","range":"1 Bq/dm3 – 4,5 kBq/dm3"}],"search_zh":"水、废水、生活饮用水 α 能谱法 范围 RW wydanie 9 z dnia 22.08.2024","test_object_zh":"水、废水、生活饮用水","technique_zh":"α 能谱法"},{"_id":"6a5e8827b979cd801f4834b8","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Stężenie izotopu radonu 222Rn","methodology_en":"Concentration of the radon isotope 222Rn","parameters":[{"name":"Zakres","range":"10 Bq/m3 – 2 MBq/m3"}],"parameters_en":[{"name":"Range","range":"10 Bq/m3 – 2 MBq/m3"}],"technique":"Metoda spektrometrii promieniowania alfa","techniques":["Metoda spektrometrii promieniowania alfa"],"technique_en":"Alpha spectrometry method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn\nZakres 10 Bq/m3 – 2 MBq/m3\nMetoda spektrometrii promieniowania alfa","reference":"RG wydanie 8 z dnia 22.08.2024","norm_bases":["RG wydanie 8 z dnia 22.08.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Stężenie izotopu radonu 222Rn\nZakres 10 Bq/m3 – 2 MBq/m3\nMetoda spektrometrii promieniowania alfa RG wydanie 8 z dnia 22.08.2024 Powietrze Stezenie izotopu radonu 222Rn\nZakres 10 Bq/m3 – 2 MBq/m3\nMetoda spektrometrii promieniowania alfa RG wydanie 8 z dnia 22.08.2024","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Concentration of the radon isotope 222Rn Alpha spectrometry method Range RG wydanie 8 z dnia 22.08.2024","parameters_zh":[{"name":"范围","range":"10 Bq/m3 – 2 MBq/m3"}],"search_zh":"空气 α 能谱法 范围 RG wydanie 8 z dnia 22.08.2024","test_object_zh":"空气","technique_zh":"α 能谱法"},{"_id":"6a5e8827b979cd801f4834b9","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Stężenie izotopu radonu 222Rn, Zakres dla 1 miesiąca ekspozycji detektora: 42 Bq/m3 – 16,67 kBq/m3","methodology_en":"Radon isotope 222Rn concentration, Range for 1 month detector exposure: 42 Bq/m3 – 16,67 kBq/m3","parameters":[],"parameters_en":[],"technique":"Metoda detektorów śladowych","techniques":["Metoda detektorów śladowych"],"technique_en":"Track detector method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn, Zakres dla 1 miesiąca ekspozycji detektora: 42 Bq/m3 – 16,67 kBq/m3\nMetoda detektorów śladowych","reference":"CR wydanie 7 z dnia 22.08.2024","norm_bases":["CR wydanie 7 z dnia 22.08.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Stężenie izotopu radonu 222Rn, Zakres dla 1 miesiąca ekspozycji detektora: 42 Bq/m3 – 16,67 kBq/m3\nMetoda detektorów śladowych CR wydanie 7 z dnia 22.08.2024 Powietrze Stezenie izotopu radonu 222Rn, Zakres dla 1 miesiaca ekspozycji detektora: 42 Bq/m3 – 16,67 kBq/m3\nMetoda detektorow sladowych CR wydanie 7 z dnia 22.08.2024","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Radon isotope 222Rn concentration, Range for 1 month detector exposure: 42 Bq/m3 – 16,67 kBq/m3 Track detector method CR wydanie 7 z dnia 22.08.2024","search_zh":"空气 径迹探测器法 CR wydanie 7 z dnia 22.08.2024","test_object_zh":"空气","technique_zh":"径迹探测器法"},{"_id":"6a5e8827b979cd801f4834ba","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 30,5 kBq*h/m3 – 12000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach","methodology_en":"Radon isotope 222Rn concentration, Range for any detector exposure time: 30,5 kBq*h/m3 – 12000 kBq*h/m3 divided by the detector exposure time expressed in hours","parameters":[],"parameters_en":[],"technique":"Metoda detektorów śladowych","techniques":["Metoda detektorów śladowych"],"technique_en":"Track detector method","computed":[],"computed_en":[],"activity":"Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 30,5 kBq*h/m3 – 12000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach\nMetoda detektorów śladowych","reference":"CR wydanie 7 z dnia 22.08.2024","norm_bases":["CR wydanie 7 z dnia 22.08.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Stężenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 30,5 kBq*h/m3 – 12000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrażony w godzinach\nMetoda detektorów śladowych CR wydanie 7 z dnia 22.08.2024 Powietrze Stezenie izotopu radonu 222Rn, Zakres dla dowolnego czasu ekspozycji detektora: 30,5 kBq*h/m3 – 12000 kBq*h/m3 podzielony przez czas ekspozycji detektora wyrazony w godzinach\nMetoda detektorow sladowych CR wydanie 7 z dnia 22.08.2024","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Radon isotope 222Rn concentration, Range for any detector exposure time: 30,5 kBq*h/m3 – 12000 kBq*h/m3 divided by the detector exposure time expressed in hours Track detector method CR wydanie 7 z dnia 22.08.2024","search_zh":"空气 径迹探测器法 CR wydanie 7 z dnia 22.08.2024","test_object_zh":"空气","technique_zh":"径迹探测器法"},{"_id":"6a5e8827b979cd801f4834bb","lab_id":"69ad52a3de79e566650fb3f6","country":"PL","accr_number":"AB 788","accr_body":"PCA","test_object":"Powietrze","test_object_en":"Air","methodology":"Średnioroczne stężenia radonu (z obliczeń)","methodology_en":"Annual average radon concentrations (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Średnioroczne stężenia radonu (z obliczeń)","reference":"CR_I01 wydanie 3 z dnia 25.10.2024","norm_bases":["CR_I01 wydanie 3 z dnia 25.10.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Powietrze Średnioroczne stężenia radonu (z obliczeń) CR_I01 wydanie 3 z dnia 25.10.2024 Powietrze Srednioroczne stezenia radonu (z obliczen) CR_I01 wydanie 3 z dnia 25.10.2024","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Air Annual average radon concentrations (calculated) CR_I01 wydanie 3 z dnia 25.10.2024","search_zh":"空气 CR_I01 wydanie 3 z dnia 25.10.2024","test_object_zh":"空气"}],"has_pdf":true}