{"lab":{"_id":"69ad52a3de79e566650fb3f2","accr_number":"AB 786","country":"PL","accr_body":"PCA","address":"- ODDZIAŁ ELEKTROWNIA OPOLE, WYDZIAŁ LABORATORIÓW, ul. Elektrowniana 25, 45-920 Opole","categories":["petro","water","materials"],"city":"Opole","imported_at":"2026-03-08T10:42:43.265Z","methods_count":49,"name":"PGE GÓRNICTWO I ENERGETYKA KONWENCJONALNA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_786.pdf"],"scope_summary":"","search_text":"pge górnictwo i energetyka konwencjonalna s.a. - oddział elektrownia opole, wydział laboratoriów, ul. elektrowniana 25, 45-920 opole water other materials pharma electronics food petro construction environment","status":"active","updated_at":"2026-03-08T14:51:40.379Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:40.379Z","location":{"type":"Point","coordinates":[17.9213,50.6751]},"email_confidence":"high","email_mx":true,"email_source":"https://elopole.pgegiek.pl/kontakt","fields_of_testing":[{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"C/28; C/32","pl":"Badania chemiczne wody, odpadów","en":"Chemical tests of water, waste"},{"codes":"C/10","pl":"Badania chemiczne paliw stałych, paliw ciekłych","en":"Chemical tests of solid fuels, liquid fuels"},{"codes":"C/4","pl":"Badania chemiczne wyrobów chemicznych","en":"Chemical tests of chemical products"},{"codes":"N/5","pl":"Badania właściwości fizycznych materiałów budowlanych","en":"Tests of physical properties of building meterials"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"},{"codes":"N/28; N/32","pl":"Badania właściwości fizycznych wody, odpadów","en":"Tests of physical properties of water, waste"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych, paliw ciekłych","en":"Tests of physical properties of solid fuels, liquid fuels"},{"codes":"N/4","pl":"Badania właściwości fizycznych wyrobów chemicznych","en":"Tests of physical properties of chemical products"}],"issue":{"no":"25","date":"20.11.2025"},"parse_date":"2026-07-20T07:09:50.587Z","parse_source":"script-pdfplumber","map_coord":[50.746356,17.887943],"map_geo":"nominatim-street","has_en":true,"category_counts":{"petro":24,"water":19,"other":5,"materials":3,"environment":2,"construction":1},"category_scores":{"petro":10.67,"water":6.69,"other":0.46,"materials":0.17,"environment":0.07,"construction":0.02},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825eab1","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Biochemiczne Zapotrzebowanie Tlenu","methodology_en":"Biochemical Oxygen Demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 300) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 300) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5\nZakres (1 – 300) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019:12","norm_bases":["PN-EN ISO 5815-1:2019:12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5\nZakres (1 – 300) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019:12 Scieki, woda Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5\nZakres (1 – 300) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019:12","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Biochemical Oxygen Demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019:12","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 300) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019:12","technique_zh":"电化学法","test_object_zh":"废水、水","methodology_zh":"生化需氧量"},{"_id":"6a5dc9bef1c10c8ce825eab2","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Biochemiczne Zapotrzebowanie Tlenu","methodology_en":"Biochemical Oxygen Demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5\nZakres (0,5 – 6) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5\nZakres (0,5 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki, woda Biochemiczne Zapotrzebowanie Tlenu\nZakres:\nBZT5\nZakres (0,5 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Biochemical Oxygen Demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6) mg/l O2"}],"search_zh":"废水、水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"废水、水","methodology_zh":"生化需氧量"},{"_id":"6a5dc9bef1c10c8ce825eab3","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Chemiczne Zapotrzebowanie Tlenu","methodology_en":"Chemical Oxygen Demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10 – 1200) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10 – 1200) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne Zapotrzebowanie Tlenu\nZakres:\nChZT-Cr\nZakres (10 – 1200) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Chemiczne Zapotrzebowanie Tlenu\nZakres:\nChZT-Cr\nZakres (10 – 1200) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, woda Chemiczne Zapotrzebowanie Tlenu\nZakres:\nChZT-Cr\nZakres (10 – 1200) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Chemical Oxygen Demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10 – 1200) mg/l O2"}],"search_zh":"废水、水 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eab4","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 30) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 30) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 30) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie azotu Kjeldahla\nZakres (1,0 – 30) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki, woda Stezenie azotu Kjeldahla\nZakres (1,0 – 30) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 30) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eab5","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"Procedura 166/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 166/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie azotu ogólnego (z obliczeń) Procedura 166/TWL/PB z dnia 20.10.2016 r. Scieki, woda Stezenie azotu ogolnego (z obliczen) Procedura 166/TWL/PB z dnia 20.10.2016 r.","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Total nitrogen concentration (calculated) Procedura 166/TWL/PB z dnia 20.10.2016 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"废水、水 总氮浓度（计算值） Procedura 166/TWL/PB z dnia 20.10.2016 r.","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eab6","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie pierwiastków:","methodology_en":"Element concentrations:","parameters":[{"name":"Ołów","range":"(0,0025 – 100) mg/l"},{"name":"Miedź","range":"(0,001 – 100) mg/l"},{"name":"Nikiel","range":"(0,001 – 100) mg/l"},{"name":"Chrom","range":"(0,002 – 100) mg/l"},{"name":"Kadm","range":"(0,0001 – 100) mg/l"},{"name":"Żelazo","range":"(0,005 – 1000) mg/l"},{"name":"Cynk","range":"(0,001 – 100) mg/l"},{"name":"Fosfor","range":"(0,050 – 5,0) mg/l"},{"name":"Wapń","range":"(1,00 – 400) mg/l"},{"name":"Arsen","range":"(0,0050 – 1,00) mg/l"},{"name":"Bor","range":"(0,010 – 100) mg/l"},{"name":"Glin","range":"(0,050 – 10,0) mg/l"},{"name":"Potas","range":"(1,00 – 200) mg/l"},{"name":"Sód","range":"(1,00 – 200) mg/l"}],"parameters_en":[{"name":"Lead","range":"(0,0025 – 100) mg/l"},{"name":"Copper","range":"(0,001 – 100) mg/l"},{"name":"Nickel","range":"(0,001 – 100) mg/l"},{"name":"Chromium","range":"(0,002 – 100) mg/l"},{"name":"Cadmium","range":"(0,0001 – 100) mg/l"},{"name":"Iron","range":"(0,005 – 1000) mg/l"},{"name":"Zinc","range":"(0,001 – 100) mg/l"},{"name":"Phosphorus","range":"(0,050 – 5,0) mg/l"},{"name":"Calcium","range":"(1,00 – 400) mg/l"},{"name":"Arsenic","range":"(0,0050 – 1,00) mg/l"},{"name":"Boron","range":"(0,010 – 100) mg/l"},{"name":"Aluminium","range":"(0,050 – 10,0) mg/l"},{"name":"Potassium","range":"(1,00 – 200) mg/l"},{"name":"Sodium","range":"(1,00 – 200) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków:\nZakres:\nOłów (0,0025 – 100) mg/l\nMiedź (0,001 – 100) mg/l\nNikiel (0,001 – 100) mg/l\nChrom (0,002 – 100) mg/l\nKadm (0,0001 – 100) mg/l\nŻelazo (0,005 – 1000) mg/l\nCynk (0,001 – 100) mg/l\nFosfor (0,050 – 5,0) mg/l\nWapń (1,00 – 400) mg/l\nArsen (0,0050 – 1,00) mg/l\nBor (0,010 – 100) mg/l\nGlin (0,050 – 10,0) mg/l\nPotas (1,00 – 200) mg/l\nSód (1,00 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie pierwiastków:\nZakres:\nOłów (0,0025 – 100) mg/l\nMiedź (0,001 – 100) mg/l\nNikiel (0,001 – 100) mg/l\nChrom (0,002 – 100) mg/l\nKadm (0,0001 – 100) mg/l\nŻelazo (0,005 – 1000) mg/l\nCynk (0,001 – 100) mg/l\nFosfor (0,050 – 5,0) mg/l\nWapń (1,00 – 400) mg/l\nArsen (0,0050 – 1,00) mg/l\nBor (0,010 – 100) mg/l\nGlin (0,050 – 10,0) mg/l\nPotas (1,00 – 200) mg/l\nSód (1,00 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki, woda Stezenie pierwiastkow:\nZakres:\nOlow (0,0025 – 100) mg/l\nMiedz (0,001 – 100) mg/l\nNikiel (0,001 – 100) mg/l\nChrom (0,002 – 100) mg/l\nKadm (0,0001 – 100) mg/l\nZelazo (0,005 – 1000) mg/l\nCynk (0,001 – 100) mg/l\nFosfor (0,050 – 5,0) mg/l\nWapn (1,00 – 400) mg/l\nArsen (0,0050 – 1,00) mg/l\nBor (0,010 – 100) mg/l\nGlin (0,050 – 10,0) mg/l\nPotas (1,00 – 200) mg/l\nSod (1,00 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Element concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) Lead Copper Nickel Chromium Cadmium Iron Zinc Phosphorus Calcium Arsenic Boron Aluminium Potassium Sodium PN-EN ISO 11885:2009","methodology_zh":"元素浓度：","parameters_zh":[{"name":"铅","range":"(0,0025 – 100) mg/l"},{"name":"铜","range":"(0,001 – 100) mg/l"},{"name":"镍","range":"(0,001 – 100) mg/l"},{"name":"铬","range":"(0,002 – 100) mg/l"},{"name":"镉","range":"(0,0001 – 100) mg/l"},{"name":"铁","range":"(0,005 – 1000) mg/l"},{"name":"锌","range":"(0,001 – 100) mg/l"},{"name":"磷","range":"(0,050 – 5,0) mg/l"},{"name":"钙","range":"(1,00 – 400) mg/l"},{"name":"砷","range":"(0,0050 – 1,00) mg/l"},{"name":"硼","range":"(0,010 – 100) mg/l"},{"name":"铝","range":"(0,050 – 10,0) mg/l"},{"name":"钾","range":"(1,00 – 200) mg/l"},{"name":"钠","range":"(1,00 – 200) mg/l"}],"search_zh":"废水、水 元素浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 铅 铜 镍 铬 镉 铁 锌 磷 钙 砷 硼 铝 钾 钠 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eab7","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie pierwiastków:","methodology_en":"Element concentrations:","parameters":[{"name":"Ołów","range":"(1,0 – 100) μg/l"},{"name":"Miedź","range":"(0,5 – 100) μg/l"},{"name":"Nikiel","range":"(1,0 – 100) μg/l"},{"name":"Kadm","range":"(0,1 – 5) μg/l"},{"name":"Chrom","range":"(1,0 – 100) μg/l"},{"name":"Żelazo","range":"(5,0 – 100) μg/l"},{"name":"Arsen","range":"(5,0 – 200) μg/l"}],"parameters_en":[{"name":"Lead","range":"(1,0 – 100) μg/l"},{"name":"Copper","range":"(0,5 – 100) μg/l"},{"name":"Nickel","range":"(1,0 – 100) μg/l"},{"name":"Cadmium","range":"(0,1 – 5) μg/l"},{"name":"Chromium","range":"(1,0 – 100) μg/l"},{"name":"Iron","range":"(5,0 – 100) μg/l"},{"name":"Arsenic","range":"(5,0 – 200) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków:\nZakres:\nOłów (1,0 – 100) μg/l\nMiedź (0,5 – 100) μg/l\nNikiel (1,0 – 100) μg/l\nKadm (0,1 – 5) μg/l\nChrom (1,0 – 100) μg/l\nŻelazo (5,0 – 100) μg/l\nArsen (5,0 – 200) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie pierwiastków:\nZakres:\nOłów (1,0 – 100) μg/l\nMiedź (0,5 – 100) μg/l\nNikiel (1,0 – 100) μg/l\nKadm (0,1 – 5) μg/l\nChrom (1,0 – 100) μg/l\nŻelazo (5,0 – 100) μg/l\nArsen (5,0 – 200) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki, woda Stezenie pierwiastkow:\nZakres:\nOlow (1,0 – 100) μg/l\nMiedz (0,5 – 100) μg/l\nNikiel (1,0 – 100) μg/l\nKadm (0,1 – 5) μg/l\nChrom (1,0 – 100) μg/l\nZelazo (5,0 – 100) μg/l\nArsen (5,0 – 200) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water","materials"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Element concentrations: Electrothermal atomization atomic absorption spectrometry (ETAAS) Lead Copper Nickel Cadmium Chromium Iron Arsenic PN-EN ISO 15586:2005","methodology_zh":"元素浓度：","parameters_zh":[{"name":"铅","range":"(1,0 – 100) μg/l"},{"name":"铜","range":"(0,5 – 100) μg/l"},{"name":"镍","range":"(1,0 – 100) μg/l"},{"name":"镉","range":"(0,1 – 5) μg/l"},{"name":"铬","range":"(1,0 – 100) μg/l"},{"name":"铁","range":"(5,0 – 100) μg/l"},{"name":"砷","range":"(5,0 – 200) μg/l"}],"search_zh":"废水、水 元素浓度： 电热原子化原子吸收光谱法（ETAAS） 铅 铜 镍 镉 铬 铁 砷 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eab8","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,0050 – 600) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,0050 – 600) μg/l"}],"technique":"Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","techniques":["Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)"],"technique_en":"Cold vapour atomic fluorescence spectrometry (CVAFS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,0050 – 600) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie rtęci\nZakres (0,0050 – 600) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009 Scieki, woda Stezenie rteci\nZakres (0,0050 – 600) μg/l\nMetoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Mercury concentration Cold vapour atomic fluorescence spectrometry (CVAFS) Range PN-EN ISO 17852:2009","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0050 – 600) μg/l"}],"search_zh":"废水、水 汞浓度 冷蒸气原子荧光光谱法（CVAFS） 范围 PN-EN ISO 17852:2009","test_object_zh":"废水、水","technique_zh":"冷蒸气原子荧光光谱法（CVAFS）"},{"_id":"6a5dc9bef1c10c8ce825eab9","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,025 – 300) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,025 – 300) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,025 – 300) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012+Ap1:2016","norm_bases":["PN-EN ISO 12846:2012+Ap1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie rtęci\nZakres (0,025 – 300) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016 Scieki, woda Stezenie rteci\nZakres (0,025 – 300) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012+Ap1:2016","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 300) μg/l"}],"search_zh":"废水、水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012+Ap1:2016","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eaba","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,002 – 0,1) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,002 – 0,1) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,002 – 0,1) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 p. 5","norm_bases":["PN-ISO 6439:1994 p. 5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Indeks fenolowy\nZakres (0,002 – 0,1) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 p. 5 Scieki, woda Indeks fenolowy\nZakres (0,002 – 0,1) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 p. 5","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Phenol index Spectrophotometric method Range PN-ISO 6439:1994 p. 5","parameters_zh":[{"name":"范围","range":"(0,002 – 0,1) mg/l"}],"search_zh":"废水、水 酚指数 分光光度法 范围 PN-ISO 6439:1994 p. 5","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"酚指数"},{"_id":"6a5dc9bef1c10c8ce825eabb","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, woda Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eabc","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN- EN ISO 10523:2012","norm_bases":["PN- EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN- EN ISO 10523:2012 Scieki, woda pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN- EN ISO 10523:2012","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water pH Potentiometric method Range PN- EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"废水、水 pH 值 电位法 范围 PN- EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eabd","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 5400) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 5400) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 5400) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Przewodność elektryczna właściwa\nZakres (10 – 5400) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Scieki, woda Przewodnosc elektryczna wlasciwa\nZakres (10 – 5400) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 5400) μS/cm"}],"search_zh":"废水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eabe","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Scieki, woda Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"废水、水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"废水、水","methodology_zh":"矿物油指数"},{"_id":"6a5dc9bef1c10c8ce825eabf","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie węgla organicznego","methodology_en":"Organic carbon concentration","parameters":[{"name":"Zakres","range":"(0,3 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,3 – 100) mg/l"}],"technique":"Metoda spektrometrii w zakresie podczerwieni IR","techniques":["Metoda spektrometrii w zakresie podczerwieni IR"],"technique_en":"Spectrometry method in the infrared range IR","computed":[],"computed_en":[],"activity":"Stężenie węgla organicznego\nZakres (0,3 – 100) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie węgla organicznego\nZakres (0,3 – 100) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999 Scieki, woda Stezenie wegla organicznego\nZakres (0,3 – 100) mg/l\nMetoda spektrometrii w zakresie podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Organic carbon concentration Spectrometry method in the infrared range IR Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(0,3 – 100) mg/l"}],"search_zh":"废水、水 红外光谱法 IR 范围 PN-EN 1484:1999","test_object_zh":"废水、水","technique_zh":"红外光谱法 IR"},{"_id":"6a5dc9bef1c10c8ce825eac0","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie anionów:","methodology_en":"Anion concentrations:","parameters":[{"name":"Azotany","range":"(0,10 – 50) mg/l"},{"name":"Azotyny","range":"(0,10 – 20) mg/l"},{"name":"Chlorki","range":"(1,0 – 2500) mg/l"},{"name":"Siarczany","range":"(1,0 – 1000) mg/l"},{"name":"Fluorki","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"Nitrates","range":"(0,10 – 50) mg/l"},{"name":"Nitrites","range":"(0,10 – 20) mg/l"},{"name":"Chlorides","range":"(1,0 – 2500) mg/l"},{"name":"Sulfates","range":"(1,0 – 1000) mg/l"},{"name":"Fluorides","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów:\nZakres:\nAzotany (0,10 – 50) mg/l\nAzotyny (0,10 – 20) mg/l\nChlorki (1,0 – 2500) mg/l\nSiarczany (1,0 – 1000) mg/l\nFluorki (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC1:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC1:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie anionów:\nZakres:\nAzotany (0,10 – 50) mg/l\nAzotyny (0,10 – 20) mg/l\nChlorki (1,0 – 2500) mg/l\nSiarczany (1,0 – 1000) mg/l\nFluorki (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC1:2012 Scieki, woda Stezenie anionow:\nZakres:\nAzotany (0,10 – 50) mg/l\nAzotyny (0,10 – 20) mg/l\nChlorki (1,0 – 2500) mg/l\nSiarczany (1,0 – 1000) mg/l\nFluorki (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC1:2012","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Anion concentrations: Ion chromatography with conductometric detection (IC-CD) Nitrates Nitrites Chlorides Sulfates Fluorides PN-EN ISO 10304-1:2009 +AC1:2012","methodology_zh":"阴离子浓度：","parameters_zh":[{"name":"硝酸盐","range":"(0,10 – 50) mg/l"},{"name":"亚硝酸盐","range":"(0,10 – 20) mg/l"},{"name":"氯化物","range":"(1,0 – 2500) mg/l"},{"name":"硫酸盐","range":"(1,0 – 1000) mg/l"},{"name":"氟化物","range":"(0,10 – 100) mg/l"}],"search_zh":"废水、水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 硝酸盐 亚硝酸盐 氯化物 硫酸盐 氟化物 PN-EN ISO 10304-1:2009 +AC1:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"废水、水"},{"_id":"6a5dc9bef1c10c8ce825eac1","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie kationów:","methodology_en":"Cation concentrations:","parameters":[{"name":"amonowy","range":"(0,10 – 100) mg/l"},{"name":"sodowy","range":"(0,10 – 100) mg/l"},{"name":"magnezowy","range":"(0,50 – 100) mg/l"},{"name":"potasowy","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"ammonium","range":"(0,10 – 100) mg/l"},{"name":"sodium","range":"(0,10 – 100) mg/l"},{"name":"magnesium","range":"(0,50 – 100) mg/l"},{"name":"potassium","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie kationów:\nZakres:\namonowy (0,10 – 100) mg/l\nsodowy (0,10 – 100) mg/l\nmagnezowy (0,50 – 100) mg/l\npotasowy (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN- EN ISO 14911:2002","norm_bases":["PN- EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie kationów:\nZakres:\namonowy (0,10 – 100) mg/l\nsodowy (0,10 – 100) mg/l\nmagnezowy (0,50 – 100) mg/l\npotasowy (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN- EN ISO 14911:2002 Scieki, woda Stezenie kationow:\nZakres:\namonowy (0,10 – 100) mg/l\nsodowy (0,10 – 100) mg/l\nmagnezowy (0,50 – 100) mg/l\npotasowy (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN- EN ISO 14911:2002","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Cation concentrations: Ion chromatography with conductometric detection (IC-CD) ammonium sodium magnesium potassium PN- EN ISO 14911:2002","search_zh":"废水、水 阳离子浓度： 离子色谱-电导检测法（IC-CD） 铵态 PN- EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"废水、水","methodology_zh":"阳离子浓度：","parameters_zh":[{"name":"铵态","range":"(0,10 – 100) mg/l"},{"name":"sodowy","range":"(0,10 – 100) mg/l"},{"name":"magnezowy","range":"(0,50 – 100) mg/l"},{"name":"potasowy","range":"(0,10 – 100) mg/l"}]},{"_id":"6a5dc9bef1c10c8ce825eac2","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda automatyczna; Metoda manualna","techniques":["Metoda automatyczna","Metoda manualna"],"technique_en":"Automatic method; Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna; Metoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Automatic method; Manual method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 自动法；手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"自动法；手工法"},{"_id":"6a5dc9bef1c10c8ce825eac3","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny","test_object_en":"Chemical products: limestone","methodology":"Zawartość CaCO3","methodology_en":"CaCO3 content","parameters":[{"name":"Zakres","range":"(80,0 – 99,0) %"}],"parameters_en":[{"name":"Range","range":"(80,0 – 99,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość CaCO3\nZakres (80,0 – 99,0) %\nMetoda miareczkowa","reference":"Procedura 141/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 141/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby chemiczne: kamień wapienny Zawartość CaCO3\nZakres (80,0 – 99,0) %\nMetoda miareczkowa Procedura 141/TWL/PB z dnia 20.10.2016 r. Wyroby chemiczne: kamien wapienny Zawartosc CaCO3\nZakres (80,0 – 99,0) %\nMetoda miareczkowa Procedura 141/TWL/PB z dnia 20.10.2016 r.","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Chemical products: limestone CaCO3 content Titrimetric method Range Procedura 141/TWL/PB z dnia 20.10.2016 r.","parameters_zh":[{"name":"范围","range":"(80,0 – 99,0) %"}],"search_zh":"化工产品：石灰石 CaCO3 含量 滴定法 范围 Procedura 141/TWL/PB z dnia 20.10.2016 r.","technique_zh":"滴定法","test_object_zh":"化工产品：石灰石","methodology_zh":"CaCO3 含量"},{"_id":"6a5dc9bef1c10c8ce825eac4","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny","test_object_en":"Chemical products: limestone","methodology":"Zawartość MgO","methodology_en":"MgO content","parameters":[{"name":"Zakres","range":"(0,20 – 2,00) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 2,00) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość MgO\nZakres (0,20 – 2,00) %\nMetoda miareczkowa","reference":"Procedura 138/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 138/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby chemiczne: kamień wapienny Zawartość MgO\nZakres (0,20 – 2,00) %\nMetoda miareczkowa Procedura 138/TWL/PB z dnia 20.10.2016 r. Wyroby chemiczne: kamien wapienny Zawartosc MgO\nZakres (0,20 – 2,00) %\nMetoda miareczkowa Procedura 138/TWL/PB z dnia 20.10.2016 r.","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Chemical products: limestone MgO content Titrimetric method Range Procedura 138/TWL/PB z dnia 20.10.2016 r.","parameters_zh":[{"name":"范围","range":"(0,20 – 2,00) %"}],"search_zh":"化工产品：石灰石 滴定法 范围 Procedura 138/TWL/PB z dnia 20.10.2016 r.","technique_zh":"滴定法","test_object_zh":"化工产品：石灰石"},{"_id":"6a5dc9bef1c10c8ce825eac5","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny","test_object_en":"Chemical products: limestone","methodology":"Zawartość Al2O3","methodology_en":"Al2O3 content","parameters":[{"name":"Zakres","range":"(0,10 – 1,10) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 1,10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość Al2O3\nZakres (0,10 – 1,10) %\nMetoda miareczkowa","reference":"Procedura 136/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 136/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby chemiczne: kamień wapienny Zawartość Al2O3\nZakres (0,10 – 1,10) %\nMetoda miareczkowa Procedura 136/TWL/PB z dnia 20.10.2016 r. Wyroby chemiczne: kamien wapienny Zawartosc Al2O3\nZakres (0,10 – 1,10) %\nMetoda miareczkowa Procedura 136/TWL/PB z dnia 20.10.2016 r.","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Chemical products: limestone Al2O3 content Titrimetric method Range Procedura 136/TWL/PB z dnia 20.10.2016 r.","parameters_zh":[{"name":"范围","range":"(0,10 – 1,10) %"}],"search_zh":"化工产品：石灰石 滴定法 范围 Procedura 136/TWL/PB z dnia 20.10.2016 r.","technique_zh":"滴定法","test_object_zh":"化工产品：石灰石"},{"_id":"6a5dc9bef1c10c8ce825eac6","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny","test_object_en":"Chemical products: limestone","methodology":"Zawartość Fe2O3","methodology_en":"Fe2O3 content","parameters":[{"name":"Zakres","range":"(0,04 – 1,10) %"}],"parameters_en":[{"name":"Range","range":"(0,04 – 1,10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość Fe2O3\nZakres (0,04 – 1,10) %\nMetoda miareczkowa","reference":"Procedura 137/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 137/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby chemiczne: kamień wapienny Zawartość Fe2O3\nZakres (0,04 – 1,10) %\nMetoda miareczkowa Procedura 137/TWL/PB z dnia 20.10.2016 r. Wyroby chemiczne: kamien wapienny Zawartosc Fe2O3\nZakres (0,04 – 1,10) %\nMetoda miareczkowa Procedura 137/TWL/PB z dnia 20.10.2016 r.","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Chemical products: limestone Fe2O3 content Titrimetric method Range Procedura 137/TWL/PB z dnia 20.10.2016 r.","parameters_zh":[{"name":"范围","range":"(0,04 – 1,10) %"}],"search_zh":"化工产品：石灰石 滴定法 范围 Procedura 137/TWL/PB z dnia 20.10.2016 r.","technique_zh":"滴定法","test_object_zh":"化工产品：石灰石"},{"_id":"6a5dc9bef1c10c8ce825eac7","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Wyroby chemiczne: kamień wapienny","test_object_en":"Chemical products: limestone","methodology":"Zawartość SiO2 +NR","methodology_en":"SiO2 +NR content","parameters":[{"name":"Zakres","range":"(0,40 – 3,00) %"}],"parameters_en":[{"name":"Range","range":"(0,40 – 3,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość SiO2 +NR\nZakres (0,40 – 3,00) %\nMetoda wagowa","reference":"Procedura 149/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 149/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby chemiczne: kamień wapienny Zawartość SiO2 +NR\nZakres (0,40 – 3,00) %\nMetoda wagowa Procedura 149/TWL/PB z dnia 20.10.2016 r. Wyroby chemiczne: kamien wapienny Zawartosc SiO2 +NR\nZakres (0,40 – 3,00) %\nMetoda wagowa Procedura 149/TWL/PB z dnia 20.10.2016 r.","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Chemical products: limestone SiO2 +NR content Gravimetric method Range Procedura 149/TWL/PB z dnia 20.10.2016 r.","parameters_zh":[{"name":"范围","range":"(0,40 – 3,00) %"}],"search_zh":"化工产品：石灰石 重量法 范围 Procedura 149/TWL/PB z dnia 20.10.2016 r.","technique_zh":"重量法","test_object_zh":"化工产品：石灰石"},{"_id":"6a5dc9bef1c10c8ce825eac8","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(3,0 – 20,0) %"}],"parameters_en":[{"name":"Range","range":"(3,0 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (3,0 – 20,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (3,0 – 20,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (3,0 – 20,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(3,0 – 20,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825eac9","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci przemijającej","methodology_en":"Free moisture content","parameters":[{"name":"Zakres","range":"(2,0 – 12,0) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 12,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci przemijającej\nZakres (2,0 – 12,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej\nZakres (2,0 – 12,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej\nZakres (2,0 – 12,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Free moisture content Gravimetric method Range PN-G-04611:2020-06","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0) %"}],"search_zh":"固体燃料：烟煤 外在水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"外在水分含量"},{"_id":"6a5dc9bef1c10c8ce825eaca","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,6 – 5,0) %"}],"parameters_en":[{"name":"Range","range":"(0,6 – 5,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,6 – 5,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci analitycznej\nZakres (0,6 – 5,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci analitycznej\nZakres (0,6 – 5,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Analytical moisture content Gravimetric method Range PN-G-04611:2020-06","parameters_zh":[{"name":"范围","range":"(0,6 – 5,0) %"}],"search_zh":"固体燃料：烟煤 分析水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"分析水分含量"},{"_id":"6a5dc9bef1c10c8ce825eacb","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci analitycznej","methodology_en":"Analytical moisture content","parameters":[{"name":"Zakres","range":"(0,6 – 5,0) %"}],"parameters_en":[{"name":"Range","range":"(0,6 – 5,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość wilgoci analitycznej\nZakres (0,6 – 5,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci analitycznej\nZakres (0,6 – 5,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci analitycznej\nZakres (0,6 – 5,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Analytical moisture content Thermogravimetric method (TGA) Range PN-G-04560:1998","parameters_zh":[{"name":"范围","range":"(0,6 – 5,0) %"}],"search_zh":"固体燃料：烟煤 分析水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤","methodology_zh":"分析水分含量"},{"_id":"6a5dc9bef1c10c8ce825eacc","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci pierwszego stopnia","methodology_en":"First-stage moisture content","parameters":[{"name":"Zakres","range":"(2,0 – 12,0) %"}],"parameters_en":[{"name":"Range","range":"(2,0 – 12,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia\nZakres (2,0 – 12,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia\nZakres (2,0 – 12,0) %\nMetoda wagowa PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia\nZakres (2,0 – 12,0) %\nMetoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal First-stage moisture content Gravimetric method Range PN-ISO 589:2006","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-ISO 589:2006","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825eacd","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci drugiego stopnia","methodology_en":"Second-stage moisture content","parameters":[{"name":"Zakres","range":"(0,5 – 4,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 4,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia\nZakres (0,5 – 4,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A2","norm_bases":["PN-ISO 589:2006 Metoda A2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia\nZakres (0,5 – 4,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia\nZakres (0,5 – 4,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A2","categories":["petro"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Second-stage moisture content Gravimetric method Range PN-ISO 589:2006 Metoda A2","parameters_zh":[{"name":"范围","range":"(0,5 – 4,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分含量 重量法 范围 PN-ISO 589:2006 Metoda A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分含量"},{"_id":"6a5dc9bef1c10c8ce825eace","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 | PN-G-04611:2020-06","norm_bases":["PN-ISO 589:2006","PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 | PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 | PN-G-04611:2020-06","categories":["petro"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 | PN-G-04611:2020-06","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 | PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825eacf","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(10,0 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (10,0 – 40,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (10,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (10,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(10,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825ead0","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(10,0 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(10,0 – 40,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"technique_en":"Thermogravimetric method (TGA)","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (10,0 – 40,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (10,0 – 40,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (10,0 – 40,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(10,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825ead1","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,30 – 3,00) %"}],"parameters_en":[{"name":"Range","range":"(0,30 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,30 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,30 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,30 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001 | ISO 19579:2006","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,30 – 3,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825ead2","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(19 000 – 35 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(19 000 – 35 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (19 000 – 35 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (19 000 – 35 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-81/G-04513 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (19 000 – 35 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-81/G-04513","categories":["petro"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-81/G-04513","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(19 000 – 35 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825ead3","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(19 000 – 31 000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(19 000 – 31 000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (19 000 – 31 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres:\nZakres (19 000 – 31 000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres:\nZakres (19 000 – 31 000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-ISO 1928:2020-05","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(19 000 – 31 000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825ead4","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(3,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a5dc9bef1c10c8ce825ead5","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(40,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(40,0 – 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (40,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Procedura 04/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 04/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (40,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR Procedura 04/TWL/PB z dnia 20.10.2016 r. Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (40,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR Procedura 04/TWL/PB z dnia 20.10.2016 r.","categories":["petro"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range Procedura 04/TWL/PB z dnia 20.10.2016 r.","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(40,0 – 80,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 Procedura 04/TWL/PB z dnia 20.10.2016 r.","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825ead6","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość wodoru","methodology_en":"Hydrogen content","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) %"}],"parameters_en":[{"name":"Range","range":"(3,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025 Paliwa stale: wegiel kamienny Zawartosc wodoru\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025","categories":["petro"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Hydrogen content High-temperature combustion with IR detection Range ISO 29541:2025","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 氢含量 高温燃烧红外检测法 范围 ISO 29541:2025","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"氢含量"},{"_id":"6a5dc9bef1c10c8ce825ead7","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(40,0 – 80,0) %"}],"parameters_en":[{"name":"Range","range":"(40,0 – 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (40,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (40,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 29541:2025 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (40,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 29541:2025","categories":["petro"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range ISO 29541:2025","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(40,0 – 80,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 ISO 29541:2025","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a5dc9bef1c10c8ce825ead8","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","test_object_en":"Solid fuels: hard coal","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,80 – 1,80) %"}],"parameters_en":[{"name":"Range","range":"(0,80 – 1,80) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,80 – 1,80) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"ISO 29541:2025","norm_bases":["ISO 29541:2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: węgiel kamienny Zawartość azotu\nZakres (0,80 – 1,80) %\nMetoda wysokotemperaturowego spalania z detekcją TC ISO 29541:2025 Paliwa stale: wegiel kamienny Zawartosc azotu\nZakres (0,80 – 1,80) %\nMetoda wysokotemperaturowego spalania z detekcja TC ISO 29541:2025","categories":["petro"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels: hard coal Nitrogen content High-temperature combustion with TC detection Range ISO 29541:2025","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,80 – 1,80) %"}],"search_zh":"固体燃料：烟煤 氮含量 高温燃烧总碳检测法 范围 ISO 29541:2025","test_object_zh":"固体燃料：烟煤","technique_zh":"高温燃烧总碳检测法"},{"_id":"6a5dc9bef1c10c8ce825ead9","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Materiały budowlane: popiół lotny","test_object_en":"Building materials: fly ash","methodology":"Miałkość jako pozostałość na sicie 45 μm","methodology_en":"Fineness as residue on a 45 μm sieve","parameters":[{"name":"Zakres","range":"(8,0 – 70,0) %"}],"parameters_en":[{"name":"Range","range":"(8,0 – 70,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Miałkość jako pozostałość na sicie 45 μm\nZakres (8,0 – 70,0) %\nMetoda wagowa","reference":"PN-EN 451-2:2017-06","norm_bases":["PN-EN 451-2:2017-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Materiały budowlane: popiół lotny Miałkość jako pozostałość na sicie 45 μm\nZakres (8,0 – 70,0) %\nMetoda wagowa PN-EN 451-2:2017-06 Materialy budowlane: popiol lotny Mialkosc jako pozostalosc na sicie 45 μm\nZakres (8,0 – 70,0) %\nMetoda wagowa PN-EN 451-2:2017-06","categories":["materials","construction"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Building materials: fly ash Fineness as residue on a 45 μm sieve Gravimetric method Range PN-EN 451-2:2017-06","parameters_zh":[{"name":"范围","range":"(8,0 – 70,0) %"}],"search_zh":"重量法 范围 PN-EN 451-2:2017-06","technique_zh":"重量法"},{"_id":"6a5dc9bef1c10c8ce825eada","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Odpady: kod 100101, 100115, 100102, 100117, Wyroby chemiczne: popioły lotne, popioły paleniskowe, żużle, pyły z kotłów","test_object_en":"Waste: code 100101, 100115, 100102, 100117, Chemical products: fly ashes, bottom ashes, slags, boiler dusts","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,45 – 12,00) %"}],"parameters_en":[{"name":"Range","range":"(0,45 – 12,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (0,45 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 100101, 100115, 100102, 100117, Wyroby chemiczne: popioły lotne, popioły paleniskowe, żużle, pyły z kotłów Zawartość węgla całkowitego\nZakres (0,45 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady: kod 100101, 100115, 100102, 100117, Wyroby chemiczne: popioly lotne, popioly paleniskowe, zuzle, pyly z kotlow Zawartosc wegla calkowitego\nZakres (0,45 – 12,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 100101, 100115, 100102, 100117, Chemical products: fly ashes, bottom ashes, slags, boiler dusts Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,45 – 12,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a5dc9bef1c10c8ce825eadb","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Odpady: kod 100125","test_object_en":"Waste: code 100125","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(5,00 – 50,00) %"}],"parameters_en":[{"name":"Range","range":"(5,00 – 50,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (5,00 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady: kod 100125 Zawartość węgla całkowitego\nZakres (5,00 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady: kod 100125 Zawartosc wegla calkowitego\nZakres (5,00 – 50,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste: code 100125 Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(5,00 – 50,00) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a5dc9bef1c10c8ce825eadc","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki - mazut","test_object_en":"Liquid fuels: heavy fuel oil - mazut","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(80,00 – 90,00) %"}],"parameters_en":[{"name":"Range","range":"(80,00 – 90,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (80,00 – 90,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Procedura 06/TWL/PB z dnia 01.12.2023 r.","norm_bases":["Procedura 06/TWL/PB z dnia 01.12.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa ciekłe: olej opałowy ciężki - mazut Zawartość węgla całkowitego\nZakres (80,00 – 90,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR Procedura 06/TWL/PB z dnia 01.12.2023 r. Paliwa ciekle: olej opalowy ciezki - mazut Zawartosc wegla calkowitego\nZakres (80,00 – 90,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR Procedura 06/TWL/PB z dnia 01.12.2023 r.","categories":["petro"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid fuels: heavy fuel oil - mazut Total carbon content High-temperature combustion with IR detection Range Procedura 06/TWL/PB z dnia 01.12.2023 r.","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(80,00 – 90,00) %"}],"search_zh":"液体燃料：重燃料油 － 重油 总碳含量 高温燃烧红外检测法 范围 Procedura 06/TWL/PB z dnia 01.12.2023 r.","technique_zh":"高温燃烧红外检测法","test_object_zh":"液体燃料：重燃料油 － 重油"},{"_id":"6a5dc9bef1c10c8ce825eadd","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki - mazut","test_object_en":"Liquid fuels: heavy fuel oil - mazut","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,17 – 3,00) %"}],"parameters_en":[{"name":"Range","range":"(0,17 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,17 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"Procedura 07/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 07/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa ciekłe: olej opałowy ciężki - mazut Zawartość siarki całkowitej\nZakres (0,17 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR Procedura 07/TWL/PB z dnia 20.10.2016 r. Paliwa ciekle: olej opalowy ciezki - mazut Zawartosc siarki calkowitej\nZakres (0,17 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR Procedura 07/TWL/PB z dnia 20.10.2016 r.","categories":["petro"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid fuels: heavy fuel oil - mazut Total sulfur content High-temperature combustion with IR detection Range Procedura 07/TWL/PB z dnia 20.10.2016 r.","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,17 – 3,00) %"}],"search_zh":"液体燃料：重燃料油 － 重油 全硫含量 高温燃烧红外检测法 范围 Procedura 07/TWL/PB z dnia 20.10.2016 r.","technique_zh":"高温燃烧红外检测法","test_object_zh":"液体燃料：重燃料油 － 重油"},{"_id":"6a5dc9bef1c10c8ce825eade","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki - mazut","test_object_en":"Liquid fuels: heavy fuel oil - mazut","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,50 – 2,50) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 2,50) %"}],"technique":"Metoda rentgenowskiej spektroskopii fluorescencyjnej z dyspersją fali (WD-XRF)","techniques":["Metoda rentgenowskiej spektroskopii fluorescencyjnej z dyspersją fali (WD-XRF)"],"technique_en":"Wavelength dispersive X-ray fluorescence spectroscopy method (WD-XRF)","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,50 – 2,50) %\nMetoda rentgenowskiej spektroskopii fluorescencyjnej z dyspersją fali (WD-XRF)","reference":"PN-EN ISO 14596:2009","norm_bases":["PN-EN ISO 14596:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa ciekłe: olej opałowy ciężki - mazut Zawartość siarki całkowitej\nZakres (0,50 – 2,50) %\nMetoda rentgenowskiej spektroskopii fluorescencyjnej z dyspersją fali (WD-XRF) PN-EN ISO 14596:2009 Paliwa ciekle: olej opalowy ciezki - mazut Zawartosc siarki calkowitej\nZakres (0,50 – 2,50) %\nMetoda rentgenowskiej spektroskopii fluorescencyjnej z dyspersja fali (WD-XRF) PN-EN ISO 14596:2009","categories":["petro"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid fuels: heavy fuel oil - mazut Total sulfur content Wavelength dispersive X-ray fluorescence spectroscopy method (WD-XRF) Range PN-EN ISO 14596:2009","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,50 – 2,50) %"}],"search_zh":"液体燃料：重燃料油 － 重油 全硫含量 范围 PN-EN ISO 14596:2009","test_object_zh":"液体燃料：重燃料油 － 重油"},{"_id":"6a5dc9bef1c10c8ce825eadf","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki - mazut","test_object_en":"Liquid fuels: heavy fuel oil - mazut","methodology":"Zawartość azotu","methodology_en":"Nitrogen content","parameters":[{"name":"Zakres","range":"(0,20 – 0,70) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 0,70) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"technique_en":"High-temperature combustion with TC detection","computed":[],"computed_en":[],"activity":"Zawartość azotu\nZakres (0,20 – 0,70) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"ASTM D5291-21","norm_bases":["ASTM D5291-21"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa ciekłe: olej opałowy ciężki - mazut Zawartość azotu\nZakres (0,20 – 0,70) %\nMetoda wysokotemperaturowego spalania z detekcją TC ASTM D5291-21 Paliwa ciekle: olej opalowy ciezki - mazut Zawartosc azotu\nZakres (0,20 – 0,70) %\nMetoda wysokotemperaturowego spalania z detekcja TC ASTM D5291-21","categories":["petro"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid fuels: heavy fuel oil - mazut Nitrogen content High-temperature combustion with TC detection Range ASTM D5291-21","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,20 – 0,70) %"}],"search_zh":"液体燃料：重燃料油 － 重油 氮含量 高温燃烧总碳检测法 范围 ASTM D5291-21","technique_zh":"高温燃烧总碳检测法","test_object_zh":"液体燃料：重燃料油 － 重油"},{"_id":"6a5dc9bef1c10c8ce825eae0","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki - mazut","test_object_en":"Liquid fuels: heavy fuel oil - mazut","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(39000 – 44000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(39000 – 44000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (39000 – 44000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa ciekłe: olej opałowy ciężki - mazut Ciepło spalania\nZakres:\nZakres (39000 – 44000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: olej opalowy ciezki - mazut Cieplo spalania\nZakres:\nZakres (39000 – 44000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid fuels: heavy fuel oil - mazut Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-C-04062:2018-05","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(39000 – 44000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"液体燃料：重燃料油 － 重油 高位发热量 量热法 范围 低位发热量（计算值） PN-C-04062:2018-05","technique_zh":"量热法","test_object_zh":"液体燃料：重燃料油 － 重油"},{"_id":"6a5dc9bef1c10c8ce825eae1","lab_id":"69ad52a3de79e566650fb3f2","country":"PL","accr_number":"AB 786","accr_body":"PCA","test_object":"Paliwa ciekłe: olej opałowy ciężki - mazut","test_object_en":"Liquid fuels: heavy fuel oil - mazut","methodology":"Zawartość wody","methodology_en":"Water content","parameters":[{"name":"Zakres","range":"(0,05 – 5,00) % (m/m)"}],"parameters_en":[{"name":"Range","range":"(0,05 – 5,00) % (m/m)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Zawartość wody\nZakres (0,05 – 5,00) % (m/m)\nMetoda potencjometryczna","reference":"Procedura 10/TWL/PB z dnia 20.10.2016 r.","norm_bases":["Procedura 10/TWL/PB z dnia 20.10.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa ciekłe: olej opałowy ciężki - mazut Zawartość wody\nZakres (0,05 – 5,00) % (m/m)\nMetoda potencjometryczna Procedura 10/TWL/PB z dnia 20.10.2016 r. Paliwa ciekle: olej opalowy ciezki - mazut Zawartosc wody\nZakres (0,05 – 5,00) % (m/m)\nMetoda potencjometryczna Procedura 10/TWL/PB z dnia 20.10.2016 r.","categories":["petro","water"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Liquid fuels: heavy fuel oil - mazut Water content Potentiometric method Range Procedura 10/TWL/PB z dnia 20.10.2016 r.","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,05 – 5,00) % (m/m)"}],"search_zh":"液体燃料：重燃料油 － 重油 水分含量 电位法 范围 Procedura 10/TWL/PB z dnia 20.10.2016 r.","technique_zh":"电位法","test_object_zh":"液体燃料：重燃料油 － 重油"}],"has_pdf":true}