{"lab":{"_id":"69ad52a3de79e566650fb3ee","accr_number":"AB 782","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Łowiecka 24, 50-220 Wrocław","categories":["environment","water"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":157,"name":"ZEC DIAGPOM Sp z o. o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_782.pdf"],"scope_summary":"","search_text":"zec diagpom sp z o. o. laboratorium badań środowiskowych, ul. łowiecka 24, 50-220 wrocław environment metrology other materials food pharma automotive construction electronics water","status":"active","updated_at":"2026-03-08T14:51:40.227Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:40.227Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20782,podmiot.html","fields_of_testing":[],"issue":{"no":"24","date":"10.10.2025"},"parse_date":"2026-07-20T07:09:50.457Z","parse_source":"script-pdfplumber","map_coord":[51.122238,17.025485],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":65,"environment":64,"water":24,"materials":3,"construction":2,"metrology":2,"petro":1},"category_scores":{"other":26.24,"environment":25.44,"water":3.58,"materials":0.06,"construction":0.02,"metrology":0.02,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825e9fb","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa","methodology_en":"Gas volume flow rate for dynamic pressures > 5 Pa","parameters":[],"parameters_en":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"technique_en":"Stagnation pressure method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994 ←","norm_bases":["PN-Z-04030-7:1994 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 ← Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 5 Pa\nMetoda spietrzenia PN-Z-04030-7:1994 ←","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 5 Pa Stagnation pressure method PN-Z-04030-7:1994 ←","search_zh":"废气 动压 > 5 Pa 时的气体体积流量 滞止压力法 PN-Z-04030-7:1994 ←","test_object_zh":"废气","technique_zh":"滞止压力法","methodology_zh":"动压 > 5 Pa 时的气体体积流量"},{"_id":"6a5dc9bef1c10c8ce825e9fc","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994 ←","norm_bases":["PN-Z-04030-7:1994 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994 ←","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994 ←","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994 ←","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9bef1c10c8ce825e9fd","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994 ←","norm_bases":["PN-Z-04030-7:1994 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 ← Gazy odlotowe Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 ←","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994 ←","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994 ←","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825e9fe","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 ←","norm_bases":["PN-Z-04030-7:1994 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 ← Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994 ←","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994 ←","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994 ←","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825e9ff","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania frakcji pyłu","methodology_en":"Sampling for determination of the dust fraction","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania frakcji pyłu","reference":"PN-Z-04030-7:1994 ←","norm_bases":["PN-Z-04030-7:1994 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania frakcji pyłu PN-Z-04030-7:1994 ← Gazy odlotowe Pobieranie probek do oznaczania frakcji pylu PN-Z-04030-7:1994 ←","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the dust fraction PN-Z-04030-7:1994 ←","search_zh":"废气 用于测定粉尘分级的采样 PN-Z-04030-7:1994 ←","test_object_zh":"废气","methodology_zh":"用于测定粉尘分级的采样"},{"_id":"6a5dc9bef1c10c8ce825ea00","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja frakcji pyłu (z obliczeń)","methodology_en":"Emission of the dust fraction (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 ←","norm_bases":["PN-Z-04030-7:1994 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) PN-Z-04030-7:1994 ← Gazy odlotowe Emisja frakcji pylu (z obliczen) PN-Z-04030-7:1994 ←","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of the dust fraction (calculated) PN-Z-04030-7:1994 ←","search_zh":"废气 粉尘分级排放（由计算得出） PN-Z-04030-7:1994 ←","test_object_zh":"废气","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea01","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa","methodology_en":"Gas volume flow rate for dynamic pressures > 5 Pa","parameters":[],"parameters_en":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"technique_en":"Differential pressure measurement method","computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013","norm_bases":["PN-EN ISO 16911-1:2013"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 5 Pa\nMetoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 5 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013","search_zh":"废气 动压 > 5 Pa 时的气体体积流量 差压测量法 PN-EN ISO 16911-1:2013","test_object_zh":"废气","technique_zh":"差压测量法","methodology_zh":"动压 > 5 Pa 时的气体体积流量"},{"_id":"6a5dc9bef1c10c8ce825ea02","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02 ←","norm_bases":["PN-EN 13284-1:2018-02 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02 ←","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02 ←","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02 ←","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5dc9bef1c10c8ce825ea03","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,0002– 0,05) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,0002– 0,05) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,0002– 0,05) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02 ←","norm_bases":["PN-EN 13284-1:2018-02 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,0002– 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 ← Gazy odlotowe Stezenie pylu\nZakres (0,0002– 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 ←","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02 ←","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0002– 0,05) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02 ←","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea04","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02 ←","norm_bases":["PN-EN 13284-1:2018-02 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 ← Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02 ←","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02 ←","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02 ←","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea05","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania frakcji pyłu","methodology_en":"Sampling for determination of the dust fraction","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania frakcji pyłu","reference":"PN-EN 13284-1:2018-02 ←","norm_bases":["PN-EN 13284-1:2018-02 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania frakcji pyłu PN-EN 13284-1:2018-02 ← Gazy odlotowe Pobieranie probek do oznaczania frakcji pylu PN-EN 13284-1:2018-02 ←","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the dust fraction PN-EN 13284-1:2018-02 ←","search_zh":"废气 用于测定粉尘分级的采样 PN-EN 13284-1:2018-02 ←","test_object_zh":"废气","methodology_zh":"用于测定粉尘分级的采样"},{"_id":"6a5dc9bef1c10c8ce825ea06","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja frakcji pyłu (z obliczeń)","methodology_en":"Emission of the dust fraction (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02 ←","norm_bases":["PN-EN 13284-1:2018-02 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) PN-EN 13284-1:2018-02 ← Gazy odlotowe Emisja frakcji pylu (z obliczen) PN-EN 13284-1:2018-02 ←","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of the dust fraction (calculated) PN-EN 13284-1:2018-02 ←","search_zh":"废气 粉尘分级排放（由计算得出） PN-EN 13284-1:2018-02 ←","test_object_zh":"废气","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea07","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenków azotu","methodology_en":"Nitrogen oxides concentration","parameters":[{"name":"NO","range":"(0,7 – 1340) mg/m3"},{"name":"NO2","range":"(1,1 – 2050) mg/m3"},{"name":"NOx","range":"(1,1 – 2050) mg/m3"}],"parameters_en":[{"name":"NO","range":"(0,7 – 1340) mg/m3"},{"name":"NO2","range":"(1,1 – 2050) mg/m3"},{"name":"NOx","range":"(1,1 – 2050) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie tlenków azotu\nZakres:\nNO (0,7 – 1340) mg/m3\nNO2 (1,1 – 2050) mg/m3\nNOx (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04 ←","norm_bases":["PN-EN 14792:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenków azotu\nZakres:\nNO (0,7 – 1340) mg/m3\nNO2 (1,1 – 2050) mg/m3\nNOx (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ← Gazy odlotowe Stezenie tlenkow azotu\nZakres:\nNO (0,7 – 1340) mg/m3\nNO2 (1,1 – 2050) mg/m3\nNOx (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ←","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Nitrogen oxides concentration Chemiluminescence method NO NO2 NOx PN-EN 14792:2017-04 ←","search_zh":"废气 氮氧化物浓度 化学发光法 NO NO2 NOx PN-EN 14792:2017-04 ←","test_object_zh":"废气","parameters_zh":[{"name":"NO","range":"(0,7 – 1340) mg/m3"},{"name":"NO2","range":"(1,1 – 2050) mg/m3"},{"name":"NOx","range":"(1,1 – 2050) mg/m3"}],"technique_zh":"化学发光法","methodology_zh":"氮氧化物浓度"},{"_id":"6a5dc9bef1c10c8ce825ea08","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NOx (w przeliczeniu na NO2) (z obliczeń)","methodology_en":"NOx emission (calculated as NO2) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NOx (w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04 ←","norm_bases":["PN-EN 14792:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NOx (w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 ← Gazy odlotowe Emisja NOx (w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04 ←","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases NOx emission (calculated as NO2) (calculated) PN-EN 14792:2017-04 ←","search_zh":"废气 PN-EN 14792:2017-04 ←","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea09","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku siarki","methodology_en":"Sulphur dioxide concentration","parameters":[{"name":"SO2","range":"(1,5 – 8580) mg/m3"}],"parameters_en":[{"name":"SO2","range":"(1,5 – 8580) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie dwutlenku siarki\nSO2 (1,5 – 8580) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-ISO 10396:2001 ← | PN-ISO 7935:2000","norm_bases":["PN-ISO 10396:2001 ←","PN-ISO 7935:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki\nSO2 (1,5 – 8580) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 ← | PN-ISO 7935:2000 Gazy odlotowe Stezenie dwutlenku siarki\nSO2 (1,5 – 8580) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-ISO 10396:2001 ← | PN-ISO 7935:2000","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sulphur dioxide concentration Non-dispersive infrared spectrometry (NDIR) SO2 PN-ISO 10396:2001 ← | PN-ISO 7935:2000","search_zh":"废气 二氧化硫浓度 非分散红外光谱法（NDIR） SO2 PN-ISO 10396:2001 ← | PN-ISO 7935:2000","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","parameters_zh":[{"name":"SO2","range":"(1,5 – 8580) mg/m3"}],"methodology_zh":"二氧化硫浓度"},{"_id":"6a5dc9bef1c10c8ce825ea0a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2 (z obliczeń)","methodology_en":"SO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-ISO 10396:2001 ← | PN-ISO 7935:2000","norm_bases":["PN-ISO 10396:2001 ←","PN-ISO 7935:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-ISO 10396:2001 ← | PN-ISO 7935:2000 Gazy odlotowe Emisja SO2 (z obliczen) PN-ISO 10396:2001 ← | PN-ISO 7935:2000","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 emission (calculated) PN-ISO 10396:2001 ← | PN-ISO 7935:2000","search_zh":"废气 SO2 排放量（计算值） PN-ISO 10396:2001 ← | PN-ISO 7935:2000","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea0b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku węgla","methodology_en":"Carbon dioxide concentration","parameters":[{"name":"Zakres","range":"(0,1 – 30) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30) %"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla\nZakres (0,1 – 30) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019 ← | PN-ISO 10396:2001","norm_bases":["ISO 12039:2019 ←","PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla\nZakres (0,1 – 30) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 ← | PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku wegla\nZakres (0,1 – 30) %\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 ← | PN-ISO 10396:2001","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon dioxide concentration Non-dispersive infrared spectrometry (NDIR) Range ISO 12039:2019 ← | PN-ISO 10396:2001","parameters_zh":[{"name":"范围","range":"(0,1 – 30) %"}],"search_zh":"废气 二氧化碳浓度 非分散红外光谱法（NDIR） 范围 ISO 12039:2019 ← | PN-ISO 10396:2001","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"二氧化碳浓度"},{"_id":"6a5dc9bef1c10c8ce825ea0c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO2 (z obliczeń)","methodology_en":"CO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO2 (z obliczeń)","reference":"ISO 12039:2019 ← | PN-ISO 10396:2001","norm_bases":["ISO 12039:2019 ←","PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO2 (z obliczeń) ISO 12039:2019 ← | PN-ISO 10396:2001 Gazy odlotowe Emisja CO2 (z obliczen) ISO 12039:2019 ← | PN-ISO 10396:2001","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CO2 emission (calculated) ISO 12039:2019 ← | PN-ISO 10396:2001","search_zh":"废气 CO2 排放（由计算得出） ISO 12039:2019 ← | PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"CO2 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea0d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(0,8 – 6250) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,8 – 6250) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres (0,8 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04 ←","norm_bases":["PN-EN 15058:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres (0,8 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 ← Gazy odlotowe Stezenie tlenku wegla\nZakres (0,8 – 6250) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 ←","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Carbon monoxide concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 15058:2017-04 ←","parameters_zh":[{"name":"范围","range":"(0,8 – 6250) mg/m3"}],"search_zh":"废气 一氧化碳浓度 非分散红外光谱法（NDIR） 范围 PN-EN 15058:2017-04 ←","test_object_zh":"废气","methodology_zh":"一氧化碳浓度","technique_zh":"非分散红外光谱法（NDIR）"},{"_id":"6a5dc9bef1c10c8ce825ea0e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO (z obliczeń)","methodology_en":"CO emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN 15058:2017-04 ←","norm_bases":["PN-EN 15058:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN 15058:2017-04 ← Gazy odlotowe Emisja CO (z obliczen) PN-EN 15058:2017-04 ←","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CO emission (calculated) PN-EN 15058:2017-04 ←","search_zh":"废气 CO 排放量（计算值） PN-EN 15058:2017-04 ←","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea0f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(0,1 – 25) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 25) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (0,1 – 25) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04 ←","norm_bases":["PN-EN 14789:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,1 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 ← Gazy odlotowe Stezenie tlenu\nZakres (0,1 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 ←","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-EN 14789:2017-04 ←","parameters_zh":[{"name":"范围","range":"(0,1 – 25) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-EN 14789:2017-04 ←","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a5dc9bef1c10c8ce825ea10","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","methodology_en":"Sampling for the determination of sulfur dioxide concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","reference":"PN-EN 14791:2017-04 ←","norm_bases":["PN-EN 14791:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia dwutlenku siarki PN-EN 14791:2017-04 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia dwutlenku siarki PN-EN 14791:2017-04 ←","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of sulfur dioxide concentration PN-EN 14791:2017-04 ←","search_zh":"废气 用于测定二氧化硫浓度的采样 PN-EN 14791:2017-04 ←","test_object_zh":"废气","methodology_zh":"用于测定二氧化硫浓度的采样"},{"_id":"6a5dc9bef1c10c8ce825ea11","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość dwutlenku siarki","methodology_en":"Concentration / content of sulphur dioxide","parameters":[{"name":"Zakres","range":"(1 – 15000) mg/m3"},{"name":"Zakres","range":"(0,72 – 450) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(1 – 15000) mg/m3"},{"name":"Range","range":"(0,72 – 450) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość dwutlenku siarki\nZakres:\nZakres (1 – 15000) mg/m3\nZakres (0,72 – 450) mg w próbce\nMetoda toronowa","reference":"PN-EN 14791:2017-04 ←","norm_bases":["PN-EN 14791:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość dwutlenku siarki\nZakres:\nZakres (1 – 15000) mg/m3\nZakres (0,72 – 450) mg w próbce\nMetoda toronowa PN-EN 14791:2017-04 ← Gazy odlotowe Stezenie / zawartosc dwutlenku siarki\nZakres:\nZakres (1 – 15000) mg/m3\nZakres (0,72 – 450) mg w probce\nMetoda toronowa PN-EN 14791:2017-04 ←","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of sulphur dioxide Thoron method Range Range PN-EN 14791:2017-04 ←","parameters_zh":[{"name":"范围","range":"(1 – 15000) mg/m3"},{"name":"范围","range":"(0,72 – 450) mg w próbce"}],"search_zh":"废气 钍射气法 范围 范围 PN-EN 14791:2017-04 ←","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a5dc9bef1c10c8ce825ea12","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2 (z obliczeń)","methodology_en":"SO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04 ←","norm_bases":["PN-EN 14791:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 ← Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04 ←","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO2 emission (calculated) PN-EN 14791:2017-04 ←","search_zh":"废气 SO2 排放量（计算值） PN-EN 14791:2017-04 ←","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea13","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","methodology_en":"Sampling for determination of hydrogen chloride concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011 ←","norm_bases":["PN-EN 1911:2011 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011 ←","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration PN-EN 1911:2011 ←","search_zh":"废气 氯化氢浓度测定采样 PN-EN 1911:2011 ←","test_object_zh":"废气","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a5dc9bef1c10c8ce825ea14","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość chlorowodoru","methodology_en":"Hydrogen chloride concentration / content","parameters":[{"name":"Zakres","range":"(0,1 – 5000) mg/m3"},{"name":"Zakres","range":"(0,06 – 300) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,1 – 5000) mg/m3"},{"name":"Range","range":"(0,06 – 300) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,1 – 5000) mg/m3\nZakres (0,06 – 300) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011 ←","norm_bases":["PN-EN 1911:2011 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,1 – 5000) mg/m3\nZakres (0,06 – 300) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 ← Gazy odlotowe Stezenie / zawartosc chlorowodoru\nZakres:\nZakres (0,1 – 5000) mg/m3\nZakres (0,06 – 300) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011 ←","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen chloride concentration / content Spectrophotometric method Range Range PN-EN 1911:2011 ←","parameters_zh":[{"name":"范围","range":"(0,1 – 5000) mg/m3"},{"name":"范围","range":"(0,06 – 300) mg w próbce"}],"search_zh":"废气 氯化氢的浓度/含量 分光光度法 范围 范围 PN-EN 1911:2011 ←","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a5dc9bef1c10c8ce825ea15","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HCl (z obliczeń)","methodology_en":"HCl emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011 ←","norm_bases":["PN-EN 1911:2011 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 ← Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011 ←","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HCl emission (calculated) PN-EN 1911:2011 ←","search_zh":"废气 HCl 排放（由计算得出） PN-EN 1911:2011 ←","test_object_zh":"废气","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea16","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","methodology_en":"Sampling for determination of hydrogen fluoride concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006 ←","norm_bases":["ISO 15713:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006 ←","categories":["other"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration ISO 15713:2006 ←","search_zh":"废气 氟化氢浓度测定采样 ISO 15713:2006 ←","test_object_zh":"废气","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a5dc9bef1c10c8ce825ea17","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość fluorowodoru","methodology_en":"Concentration / content of hydrogen fluoride","parameters":[{"name":"Zakres","range":"(0,1 − 200) mg/m3"},{"name":"Zakres","range":"(0,01 – 20) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,1 − 200) mg/m3"},{"name":"Range","range":"(0,01 – 20) mg w próbce"}],"technique":"Metoda z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda z zastosowaniem elektrody jonoselektywnej"],"technique_en":"Method using an ion-selective electrode","computed":[],"computed_en":[],"activity":"Stężenie / zawartość fluorowodoru\nZakres:\nZakres (0,1 − 200) mg/m3\nZakres (0,01 – 20) mg w próbce\nMetoda z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006 ←","norm_bases":["ISO 15713:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość fluorowodoru\nZakres:\nZakres (0,1 − 200) mg/m3\nZakres (0,01 – 20) mg w próbce\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 ← Gazy odlotowe Stezenie / zawartosc fluorowodoru\nZakres:\nZakres (0,1 − 200) mg/m3\nZakres (0,01 – 20) mg w probce\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 ←","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of hydrogen fluoride Method using an ion-selective electrode Range Range ISO 15713:2006 ←","parameters_zh":[{"name":"范围","range":"(0,1 − 200) mg/m3"},{"name":"范围","range":"(0,01 – 20) mg w próbce"}],"search_zh":"废气 离子选择电极法 范围 范围 ISO 15713:2006 ←","test_object_zh":"废气","technique_zh":"离子选择电极法"},{"_id":"6a5dc9bef1c10c8ce825ea18","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HF (z obliczeń)","methodology_en":"HF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006 ←","norm_bases":["ISO 15713:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 ← Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006 ←","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases HF emission (calculated) ISO 15713:2006 ←","search_zh":"废气 HF 排放量（计算值） ISO 15713:2006 ←","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea19","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","methodology_en":"Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)","reference":"PN-EN 14385:2025-05 ←","norm_bases":["PN-EN 14385:2025-05 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2025-05 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2025-05 ←","categories":["materials"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) PN-EN 14385:2025-05 ←","search_zh":"废气 PN-EN 14385:2025-05 ←","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea1a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","methodology_en":"Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2025-05 ←","norm_bases":["PN-EN 14385:2025-05 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2025-05 ← Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2025-05 ←","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) PN-EN 14385:2025-05 ←","search_zh":"废气 As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出） PN-EN 14385:2025-05 ←","test_object_zh":"废气","methodology_zh":"As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea1b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia masowego PCDD/PCDF","methodology_en":"Sampling for determination of the mass concentration of PCDD/PCDF","parameters":[],"parameters_en":[],"technique":"Metoda filtracyjno-kondensacyjna","techniques":["Metoda filtracyjno-kondensacyjna"],"technique_en":"Filtration-condensation method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia masowego PCDD/PCDF\nMetoda filtracyjno-kondensacyjna","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia masowego PCDD/PCDF\nMetoda filtracyjno-kondensacyjna PN-EN 1948-1:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia masowego PCDD/PCDF\nMetoda filtracyjno-kondensacyjna PN-EN 1948-1:2006","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the mass concentration of PCDD/PCDF Filtration-condensation method PN-EN 1948-1:2006","search_zh":"废气 过滤-冷凝法 PN-EN 1948-1:2006","test_object_zh":"废气","technique_zh":"过滤-冷凝法"},{"_id":"6a5dc9bef1c10c8ce825ea1c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja PCDD/PCDF (z obliczeń)","methodology_en":"PCDD/PCDF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja PCDD/PCDF (z obliczeń)","reference":"PN-EN 1948-1:2006","norm_bases":["PN-EN 1948-1:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja PCDD/PCDF (z obliczeń) PN-EN 1948-1:2006 Gazy odlotowe Emisja PCDD/PCDF (z obliczen) PN-EN 1948-1:2006","categories":["environment"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases PCDD/PCDF emission (calculated) PN-EN 1948-1:2006","search_zh":"废气 PCDD/PCDF 排放（由计算得出） PN-EN 1948-1:2006","test_object_zh":"废气","methodology_zh":"PCDD/PCDF 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea1d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","methodology_en":"Sampling for determination of total mercury concentration","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006 ←","norm_bases":["PN-EN 13211+AC:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006 ←","categories":["other"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of total mercury concentration PN-EN 13211+AC:2006 ←","search_zh":"废气 总汞浓度测定采样 PN-EN 13211+AC:2006 ←","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a5dc9bef1c10c8ce825ea1e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie rtęci ogólnej","methodology_en":"Total mercury concentration","parameters":[{"name":"Zakres","range":"(0,0033 – 770) μg/m3"},{"name":"Zakres","range":"(0,007 – 87,5) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0033 – 770) μg/m3"},{"name":"Range","range":"(0,007 – 87,5) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci ogólnej\nZakres:\nZakres (0,0033 – 770) μg/m3\nZakres (0,007 – 87,5) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13211+AC:2006 ←","norm_bases":["PN-EN 13211+AC:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie rtęci ogólnej\nZakres:\nZakres (0,0033 – 770) μg/m3\nZakres (0,007 – 87,5) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006 ← Gazy odlotowe Stezenie rteci ogolnej\nZakres:\nZakres (0,0033 – 770) μg/m3\nZakres (0,007 – 87,5) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006 ←","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Total mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range Range PN-EN 13211+AC:2006 ←","parameters_zh":[{"name":"范围","range":"(0,0033 – 770) μg/m3"},{"name":"范围","range":"(0,007 – 87,5) μg w próbce"}],"search_zh":"废气 总汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 范围 PN-EN 13211+AC:2006 ←","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"废气","methodology_zh":"总汞浓度"},{"_id":"6a5dc9bef1c10c8ce825ea1f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja rtęci ogólnej (z obliczeń)","methodology_en":"Total mercury emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006 ←","norm_bases":["PN-EN 13211+AC:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 ← Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006 ←","categories":["environment"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Total mercury emission (calculated) PN-EN 13211+AC:2006 ←","search_zh":"废气 总汞排放量（计算值） PN-EN 13211+AC:2006 ←","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea20","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem węgla aktywnego","techniques":["Metoda aspiracyjna z zastosowaniem węgla aktywnego"],"technique_en":"Aspiration method using activated carbon","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego","reference":"PN-EN 13649:2005 ←","norm_bases":["PN-EN 13649:2005 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych\nMetoda aspiracyjna z zastosowaniem węgla aktywnego PN-EN 13649:2005 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych\nMetoda aspiracyjna z zastosowaniem wegla aktywnego PN-EN 13649:2005 ←","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds Aspiration method using activated carbon PN-EN 13649:2005 ←","search_zh":"废气 单项气态有机化合物浓度测定采样 活性炭抽气采样法 PN-EN 13649:2005 ←","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样","technique_zh":"活性炭抽气采样法"},{"_id":"6a5dc9bef1c10c8ce825ea21","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005 ←","norm_bases":["PN-EN 13649:2005 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 ← Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005 ←","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005 ←","search_zh":"废气 单项气态有机化合物排放量（计算值） PN-EN 13649:2005 ←","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea22","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pary wodnej (H20)","methodology_en":"Water vapour concentration (H20)","parameters":[{"name":"Zakres","range":"(23 – 250) g/m3"},{"name":"Zakres","range":"(3 – 40) %"},{"name":"Zakres","range":"(3,14 – 57)%"}],"parameters_en":[{"name":"Range","range":"(23 – 250) g/m3"},{"name":"Range","range":"(3 – 40) %"},{"name":"Range","range":"(3,14 – 57)%"}],"technique":"Metoda kondensacyjno-adsorpcyjna; Metoda temperaturowa","techniques":["Metoda kondensacyjno-adsorpcyjna","Metoda temperaturowa"],"technique_en":"Condensation-adsorption method; Temperature method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H20)\nZakres:\nZakres (23 – 250) g/m3\nZakres (3 – 40) %\nZakres (3,14 – 57)%\nMetoda kondensacyjno-adsorpcyjna; Metoda temperaturowa","reference":"PN-EN 14790:2017-04 ←","norm_bases":["PN-EN 14790:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pary wodnej (H20)\nZakres:\nZakres (23 – 250) g/m3\nZakres (3 – 40) %\nZakres (3,14 – 57)%\nMetoda kondensacyjno-adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04 ← Gazy odlotowe Stezenie pary wodnej (H20)\nZakres:\nZakres (23 – 250) g/m3\nZakres (3 – 40) %\nZakres (3,14 – 57)%\nMetoda kondensacyjno-adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04 ←","categories":["other"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Water vapour concentration (H20) Condensation-adsorption method; Temperature method Range Range Range PN-EN 14790:2017-04 ←","parameters_zh":[{"name":"范围","range":"(23 – 250) g/m3"},{"name":"范围","range":"(3 – 40) %"},{"name":"范围","range":"(3,14 – 57)%"}],"search_zh":"废气 冷凝-吸附法；温度法 范围 范围 范围 PN-EN 14790:2017-04 ←","test_object_zh":"废气","technique_zh":"冷凝-吸附法；温度法"},{"_id":"6a5dc9bef1c10c8ce825ea23","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(0,5 – 1000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 1000) mg/m3"}],"technique":"Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","techniques":["Metoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)"],"technique_en":"Continuous measurement with flame ionization detection (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,5 – 1000) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","reference":"PN-EN 12619:2013-05 ←","norm_bases":["PN-EN 12619:2013-05 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,5 – 1000) mg/m3\nMetoda ciągłego pomiaru z detekcją płomieniowo-jonizacyjną (FID) PN-EN 12619:2013-05 ← Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (0,5 – 1000) mg/m3\nMetoda ciaglego pomiaru z detekcja plomieniowo-jonizacyjna (FID) PN-EN 12619:2013-05 ←","categories":["other"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous measurement with flame ionization detection (FID) Range PN-EN 12619:2013-05 ←","parameters_zh":[{"name":"范围","range":"(0,5 – 1000) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 范围 PN-EN 12619:2013-05 ←","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度"},{"_id":"6a5dc9bef1c10c8ce825ea24","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05 ←","norm_bases":["PN-EN 12619:2013-05 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 ← Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05 ←","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05 ←","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN-EN 12619:2013-05 ←","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea25","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego w tym trójtlenku siarki","methodology_en":"Sampling for determination of the concentration of sulfuric acid including sulfur trioxide","parameters":[],"parameters_en":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"technique_en":"Aspiration method using absorbing solutions","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego w tym trójtlenku siarki\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","norm_bases":["LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia kwasu siarkowego w tym trójtlenku siarki\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia kwasu siarkowego w tym trojtlenku siarki\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych LBS-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of sulfuric acid including sulfur trioxide Aspiration method using absorbing solutions LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","search_zh":"废气 采用吸收液的抽气法 LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","test_object_zh":"废气","technique_zh":"采用吸收液的抽气法"},{"_id":"6a5dc9bef1c10c8ce825ea26","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość kwasu siarkowego","methodology_en":"Concentration / content of sulphuric acid","parameters":[{"name":"Zakres","range":"(0,38 – 7650) mg/m3"},{"name":"Zakres","range":"(0,102 – 459) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,38 – 7650) mg/m3"},{"name":"Range","range":"(0,102 – 459) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość kwasu siarkowego\nZakres:\nZakres (0,38 – 7650) mg/m3\nZakres (0,102 – 459) mg w próbce\nMetoda toronowa","reference":"LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","norm_bases":["LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość kwasu siarkowego\nZakres:\nZakres (0,38 – 7650) mg/m3\nZakres (0,102 – 459) mg w próbce\nMetoda toronowa LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r. Gazy odlotowe Stezenie / zawartosc kwasu siarkowego\nZakres:\nZakres (0,38 – 7650) mg/m3\nZakres (0,102 – 459) mg w probce\nMetoda toronowa LBS-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","categories":["other"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of sulphuric acid Thoron method Range Range LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","parameters_zh":[{"name":"范围","range":"(0,38 – 7650) mg/m3"},{"name":"范围","range":"(0,102 – 459) mg w próbce"}],"search_zh":"废气 钍射气法 范围 范围 LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a5dc9bef1c10c8ce825ea27","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja H2SO4 (z obliczeń)","methodology_en":"Emission of H2SO4 (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja H2SO4 (z obliczeń)","reference":"LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","norm_bases":["LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja H2SO4 (z obliczeń) LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r. Gazy odlotowe Emisja H2SO4 (z obliczen) LBS-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","categories":["environment"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of H2SO4 (calculated) LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","search_zh":"废气 LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea28","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość trójtlenku siarki","methodology_en":"Concentration / content of sulfur trioxide","parameters":[{"name":"Zakres","range":"(0,31 – 6250) mg/m3"},{"name":"Zakres","range":"(0,083 – 375) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,31 – 6250) mg/m3"},{"name":"Range","range":"(0,083 – 375) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość trójtlenku siarki\nZakres:\nZakres (0,31 – 6250) mg/m3\nZakres (0,083 – 375) mg w próbce\nMetoda toronowa","reference":"LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","norm_bases":["LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość trójtlenku siarki\nZakres:\nZakres (0,31 – 6250) mg/m3\nZakres (0,083 – 375) mg w próbce\nMetoda toronowa LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r. Gazy odlotowe Stezenie / zawartosc trojtlenku siarki\nZakres:\nZakres (0,31 – 6250) mg/m3\nZakres (0,083 – 375) mg w probce\nMetoda toronowa LBS-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","categories":["other"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Concentration / content of sulfur trioxide Thoron method Range Range LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","parameters_zh":[{"name":"范围","range":"(0,31 – 6250) mg/m3"},{"name":"范围","range":"(0,083 – 375) mg w próbce"}],"search_zh":"废气 钍射气法 范围 范围 LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a5dc9bef1c10c8ce825ea29","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO3 (z obliczeń)","methodology_en":"SO3 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO3 (z obliczeń)","reference":"LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","norm_bases":["LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO3 (z obliczeń) LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r. Gazy odlotowe Emisja SO3 (z obliczen) LBS-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","categories":["environment"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases SO3 emission (calculated) LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","search_zh":"废气 SO3 排放（由计算得出） LBŚ-PB-24 ← wydanie 3 z dnia 17.10.2022 r.","test_object_zh":"废气","methodology_zh":"SO3 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea2a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie N2O","methodology_en":"N2O concentration","parameters":[{"name":"Zakres","range":"(0,8 – 980) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,8 – 980) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie N2O\nZakres (0,8 – 980) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010 ←","norm_bases":["PN-EN ISO 21258:2010 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie N2O\nZakres (0,8 – 980) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 ← Gazy odlotowe Stezenie N2O\nZakres (0,8 – 980) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 ←","categories":["other"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases N2O concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010 ←","parameters_zh":[{"name":"范围","range":"(0,8 – 980) mg/m3"}],"search_zh":"废气 N2O 浓度 非分散红外光谱法（NDIR） 范围 PN-EN ISO 21258:2010 ←","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea2b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja N2O (z obliczeń)","methodology_en":"N2O emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja N2O (z obliczeń)","reference":"PN-EN ISO 21258:2010 ←","norm_bases":["PN-EN ISO 21258:2010 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja N2O (z obliczeń) PN-EN ISO 21258:2010 ← Gazy odlotowe Emisja N2O (z obliczen) PN-EN ISO 21258:2010 ←","categories":["environment"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases N2O emission (calculated) PN-EN ISO 21258:2010 ←","search_zh":"废气 N2O 排放（由计算得出） PN-EN ISO 21258:2010 ←","test_object_zh":"废气","methodology_zh":"N2O 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea2c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie amoniaku","methodology_en":"Ammonia concentration","parameters":[{"name":"NH3","range":"(0,38 − 38) mg/m3"}],"parameters_en":[{"name":"NH3","range":"(0,38 − 38) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)"],"technique_en":"Fourier transform infrared spectroscopy (FTIR)","computed":[],"computed_en":[],"activity":"Stężenie amoniaku\nNH3 (0,38 − 38) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","reference":"LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","norm_bases":["LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","ISO 17179:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie amoniaku\nNH3 (0,38 − 38) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016 Gazy odlotowe Stezenie amoniaku\nNH3 (0,38 − 38) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR) LBS-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","categories":["other"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia concentration Fourier transform infrared spectroscopy (FTIR) NH3 LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","search_zh":"废气 氨浓度 傅里叶变换红外光谱法（FTIR） LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","test_object_zh":"废气","methodology_zh":"氨浓度","technique_zh":"傅里叶变换红外光谱法（FTIR）"},{"_id":"6a5dc9bef1c10c8ce825ea2d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NH3 (z obliczeń)","methodology_en":"NH3 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NH3 (z obliczeń)","reference":"LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","norm_bases":["LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","ISO 17179:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NH3 (z obliczeń) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016 Gazy odlotowe Emisja NH3 (z obliczen) LBS-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","categories":["environment"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases NH3 emission (calculated) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","search_zh":"废气 NH3 排放（由计算得出） LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","test_object_zh":"废气","methodology_zh":"NH3 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea2e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania amoniaku","methodology_en":"Sampling for determination of ammonia","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of ammonia PN-EN ISO 21877:2020-03","search_zh":"废气 PN-EN ISO 21877:2020-03","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea2f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość amoniaku","methodology_en":"Ammonia concentration / content","parameters":[{"name":"Zakres","range":"(0,06 – 629) mg/m3"},{"name":"Zakres","range":"(0,095 – 236) mg/l w próbce"}],"parameters_en":[{"name":"Range","range":"(0,06 – 629) mg/m3"},{"name":"Range","range":"(0,095 – 236) mg/l w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość amoniaku\nZakres:\nZakres (0,06 – 629) mg/m3\nZakres (0,095 – 236) mg/l w próbce\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość amoniaku\nZakres:\nZakres (0,06 – 629) mg/m3\nZakres (0,095 – 236) mg/l w próbce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe Stezenie / zawartosc amoniaku\nZakres:\nZakres (0,06 – 629) mg/m3\nZakres (0,095 – 236) mg/l w probce\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia concentration / content Spectrophotometric method Range Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,06 – 629) mg/m3"},{"name":"范围","range":"(0,095 – 236) mg/l w próbce"}],"search_zh":"废气 氨的浓度/含量 分光光度法 范围 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氨的浓度/含量"},{"_id":"6a5dc9bef1c10c8ce825ea30","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja amoniaku (z obliczeń)","methodology_en":"Ammonia emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Ammonia emission (calculated) PN-EN ISO 21877:2020-03","search_zh":"废气 氨排放量（计算值） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨排放量（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea31","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie metanu","methodology_en":"Methane concentration","parameters":[{"name":"CH4","range":"(0,4 – 71,0) mg/m3"}],"parameters_en":[{"name":"CH4","range":"(0,4 – 71,0) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FT-IR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FT-IR)"],"technique_en":"Fourier transform infrared spectroscopy method (FT-IR)","computed":[],"computed_en":[],"activity":"Stężenie metanu\nCH4 (0,4 – 71,0) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FT-IR)","reference":"LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","norm_bases":["LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie metanu\nCH4 (0,4 – 71,0) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FT-IR) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. Gazy odlotowe Stezenie metanu\nCH4 (0,4 – 71,0) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FT-IR) LBS-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","categories":["other"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Methane concentration Fourier transform infrared spectroscopy method (FT-IR) CH4 LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","search_zh":"废气 甲烷浓度 LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","test_object_zh":"废气","methodology_zh":"甲烷浓度"},{"_id":"6a5dc9bef1c10c8ce825ea32","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CH4 (z obliczeń)","methodology_en":"CH4 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CH4 (z obliczeń)","reference":"LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","norm_bases":["LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CH4 (z obliczeń) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. Gazy odlotowe Emisja CH4 (z obliczen) LBS-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","categories":["environment"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases CH4 emission (calculated) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","search_zh":"废气 LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea33","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia WWA","methodology_en":"Sampling for the determination of PAH concentration","parameters":[],"parameters_en":[],"technique":"Metoda kondensacyjno-adsorbcyjna z grzanym filtrem","techniques":["Metoda kondensacyjno-adsorbcyjna z grzanym filtrem"],"technique_en":"Condensation-adsorption method with a heated filter","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia WWA\nMetoda kondensacyjno-adsorbcyjna z grzanym filtrem","reference":"ISO 11338-1:2003 – Metoda B ←","norm_bases":["ISO 11338-1:2003 – Metoda B ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia WWA\nMetoda kondensacyjno-adsorbcyjna z grzanym filtrem ISO 11338-1:2003 – Metoda B ← Gazy odlotowe Pobieranie probek do oznaczania stezenia WWA\nMetoda kondensacyjno-adsorbcyjna z grzanym filtrem ISO 11338-1:2003 – Metoda B ←","categories":["other"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of PAH concentration Condensation-adsorption method with a heated filter ISO 11338-1:2003 – Metoda B ←","search_zh":"废气 用于测定多环芳烃浓度的采样 ISO 11338-1:2003 – Metoda B ←","test_object_zh":"废气","methodology_zh":"用于测定多环芳烃浓度的采样"},{"_id":"6a5dc9bef1c10c8ce825ea34","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja WWA (z obliczeń)","methodology_en":"PAH emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja WWA (z obliczeń)","reference":"ISO 11338-1:2003 – Metoda B ←","norm_bases":["ISO 11338-1:2003 – Metoda B ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja WWA (z obliczeń) ISO 11338-1:2003 – Metoda B ← Gazy odlotowe Emisja WWA (z obliczen) ISO 11338-1:2003 – Metoda B ←","categories":["environment"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases PAH emission (calculated) ISO 11338-1:2003 – Metoda B ←","search_zh":"废气 多环芳烃排放（由计算得出） ISO 11338-1:2003 – Metoda B ←","test_object_zh":"废气","methodology_zh":"多环芳烃排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea35","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia rtęci utlenionej, elementarnej, pyłowej","methodology_en":"Sampling for determination of the concentration of oxidised, elemental and particulate mercury","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci utlenionej, elementarnej, pyłowej","reference":"LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r.","norm_bases":["LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci utlenionej, elementarnej, pyłowej LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci utlenionej, elementarnej, pylowej LBS-PB-22 wydanie 4 z dnia 30.11.2016 r.","categories":["other"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the concentration of oxidised, elemental and particulate mercury LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r.","search_zh":"废气 LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r.","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea36","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja Hg22+, Hg2+, Hg0, Hgpył (z obliczeń)","methodology_en":"Emission of Hg22+, Hg2+, Hg0, Hgdust (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja Hg22+, Hg2+, Hg0, Hgpył (z obliczeń)","reference":"LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r.","norm_bases":["LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja Hg22+, Hg2+, Hg0, Hgpył (z obliczeń) LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r. Gazy odlotowe Emisja Hg22+, Hg2+, Hg0, Hgpyl (z obliczen) LBS-PB-22 wydanie 4 z dnia 30.11.2016 r.","categories":["environment"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of Hg22+, Hg2+, Hg0, Hgdust (calculated) LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r.","search_zh":"废气 LBŚ-PB-22 wydanie 4 z dnia 30.11.2016 r.","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea37","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te)","methodology_en":"Sampling for determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te)","reference":"PN-EN 14385:2025 -05 ←","norm_bases":["PN-EN 14385:2025 -05 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te) PN-EN 14385:2025 -05 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia metali (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te) PN-EN 14385:2025 -05 ←","categories":["materials"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of metal concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te) PN-EN 14385:2025 -05 ←","search_zh":"废气 PN-EN 14385:2025 -05 ←","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea38","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te (z obliczeń)","methodology_en":"Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te (z obliczeń)","reference":"PN-EN 14385:2025 -05 ←","norm_bases":["PN-EN 14385:2025 -05 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te (z obliczeń) PN-EN 14385:2025 -05 ← Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te (z obliczen) PN-EN 14385:2025 -05 ←","categories":["environment"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Be, Sn, Zn, Se, Te (calculated) PN-EN 14385:2025 -05 ←","search_zh":"废气 PN-EN 14385:2025 -05 ←","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea39","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia masowego dioksynopodobnych PCB","methodology_en":"Sampling for determination of the mass concentration of dioxin-like PCBs","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia masowego dioksynopodobnych PCB","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia masowego dioksynopodobnych PCB PN-EN 1948-4+A1:2014-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia masowego dioksynopodobnych PCB PN-EN 1948-4+A1:2014-03","categories":["other"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of the mass concentration of dioxin-like PCBs PN-EN 1948-4+A1:2014-03","search_zh":"废气 PN-EN 1948-4+A1:2014-03","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea3a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja PCB (z obliczeń)","methodology_en":"PCB emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja PCB (z obliczeń)","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja PCB (z obliczeń) PN-EN 1948-4+A1:2014-03 Gazy odlotowe Emisja PCB (z obliczen) PN-EN 1948-4+A1:2014-03","categories":["environment"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases PCB emission (calculated) PN-EN 1948-4+A1:2014-03","search_zh":"废气 PCB 排放（由计算得出） PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","methodology_zh":"PCB 排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea3b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania formaldehydu","methodology_en":"Sampling for the determination of formaldehyde","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania formaldehydu","reference":"CEN/TS 17638:2021","norm_bases":["CEN/TS 17638:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania formaldehydu CEN/TS 17638:2021 Gazy odlotowe Pobieranie probek do oznaczania formaldehydu CEN/TS 17638:2021","categories":["other"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of formaldehyde CEN/TS 17638:2021","search_zh":"废气 CEN/TS 17638:2021","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea3c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość formaldehydu","methodology_en":"Formaldehyde concentration / content","parameters":[{"name":"Zakres","range":"(0,035 – 700) mg/m3"},{"name":"Zakres","range":"(0,0042 – 42) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,035 – 700) mg/m3"},{"name":"Range","range":"(0,0042 – 42) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,035 – 700) mg/m3\nZakres (0,0042 – 42) mg w próbce\nMetoda spektrofotometryczna","reference":"CEN/TS 17638:2021","norm_bases":["CEN/TS 17638:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,035 – 700) mg/m3\nZakres (0,0042 – 42) mg w próbce\nMetoda spektrofotometryczna CEN/TS 17638:2021 Gazy odlotowe Stezenie / zawartosc formaldehydu\nZakres:\nZakres (0,035 – 700) mg/m3\nZakres (0,0042 – 42) mg w probce\nMetoda spektrofotometryczna CEN/TS 17638:2021","categories":["other"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Formaldehyde concentration / content Spectrophotometric method Range Range CEN/TS 17638:2021","parameters_zh":[{"name":"范围","range":"(0,035 – 700) mg/m3"},{"name":"范围","range":"(0,0042 – 42) mg w próbce"}],"search_zh":"废气 甲醛的浓度/含量 分光光度法 范围 范围 CEN/TS 17638:2021","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"甲醛的浓度/含量"},{"_id":"6a5dc9bef1c10c8ce825ea3d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CH2O (z obliczeń)","methodology_en":"Emission of CH2O (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CH2O (z obliczeń)","reference":"CEN/TS 17638:2021","norm_bases":["CEN/TS 17638:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CH2O (z obliczeń) CEN/TS 17638:2021 Gazy odlotowe Emisja CH2O (z obliczen) CEN/TS 17638:2021","categories":["environment"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of CH2O (calculated) CEN/TS 17638:2021","search_zh":"废气 CEN/TS 17638:2021","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea3e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania siarkowodoru","methodology_en":"Sampling for the determination of hydrogen sulphide","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania siarkowodoru","reference":"LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","norm_bases":["LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania siarkowodoru LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r. Gazy odlotowe Pobieranie probek do oznaczania siarkowodoru LBS-PB-25 wydanie 1 z dnia 15.03.2024 r.","categories":["other"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of hydrogen sulphide LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","search_zh":"废气 LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea3f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie / zawartość siarkowodoru","methodology_en":"Hydrogen sulphide concentration / content","parameters":[{"name":"Zakres","range":"(0,055 – 373) mg/m3"},{"name":"Zakres","range":"(0,01 – 11,2) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,055 – 373) mg/m3"},{"name":"Range","range":"(0,01 – 11,2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie / zawartość siarkowodoru\nZakres:\nZakres (0,055 – 373) mg/m3\nZakres (0,01 – 11,2) mg w próbce\nMetoda spektrofotometryczna","reference":"LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","norm_bases":["LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie / zawartość siarkowodoru\nZakres:\nZakres (0,055 – 373) mg/m3\nZakres (0,01 – 11,2) mg w próbce\nMetoda spektrofotometryczna LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r. Gazy odlotowe Stezenie / zawartosc siarkowodoru\nZakres:\nZakres (0,055 – 373) mg/m3\nZakres (0,01 – 11,2) mg w probce\nMetoda spektrofotometryczna LBS-PB-25 wydanie 1 z dnia 15.03.2024 r.","categories":["other"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Hydrogen sulphide concentration / content Spectrophotometric method Range Range LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","parameters_zh":[{"name":"范围","range":"(0,055 – 373) mg/m3"},{"name":"范围","range":"(0,01 – 11,2) mg w próbce"}],"search_zh":"废气 硫化氢的浓度/含量 分光光度法 范围 范围 LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"硫化氢的浓度/含量"},{"_id":"6a5dc9bef1c10c8ce825ea40","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja H2S (z obliczeń)","methodology_en":"H2S emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja H2S (z obliczeń)","reference":"LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","norm_bases":["LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja H2S (z obliczeń) LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r. Gazy odlotowe Emisja H2S (z obliczen) LBS-PB-25 wydanie 1 z dnia 15.03.2024 r.","categories":["environment"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases H2S emission (calculated) LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","search_zh":"废气 LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea41","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania bromowanych związków opóźniających zapłon","methodology_en":"Sampling for the determination of brominated flame retardants","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania bromowanych związków opóźniających zapłon","reference":"PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r.","norm_bases":["PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania bromowanych związków opóźniających zapłon PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r. Gazy odlotowe Pobieranie probek do oznaczania bromowanych zwiazkow opozniajacych zaplon PN-EN 1948-1:2006 LBS-IR-36 wydanie 6 z dnia 11.03.2024 r.","categories":["other"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for the determination of brominated flame retardants PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r.","search_zh":"废气 PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r.","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea42","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja bromowanych związków opóźniających zapłon (z obliczeń)","methodology_en":"Emission of brominated flame retardants (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja bromowanych związków opóźniających zapłon (z obliczeń)","reference":"PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r.","norm_bases":["PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja bromowanych związków opóźniających zapłon (z obliczeń) PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r. Gazy odlotowe Emisja bromowanych zwiazkow opozniajacych zaplon (z obliczen) PN-EN 1948-1:2006 LBS-IR-36 wydanie 6 z dnia 11.03.2024 r.","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of brominated flame retardants (calculated) PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r.","search_zh":"废气 溴系阻燃剂排放（由计算得出） PN-EN 1948-1:2006 LBŚ-IR-36 wydanie 6 z dnia 11.03.2024 r.","test_object_zh":"废气","methodology_zh":"溴系阻燃剂排放（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea43","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metanu (CH4)","methodology_en":"Sampling for determination of methane concentration (CH4)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metanu (CH4)","reference":"PN-EN ISO 25139:2011 ←","norm_bases":["PN-EN ISO 25139:2011 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metanu (CH4) PN-EN ISO 25139:2011 ← Gazy odlotowe Pobieranie probek do oznaczania stezenia metanu (CH4) PN-EN ISO 25139:2011 ←","categories":["other"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Sampling for determination of methane concentration (CH4) PN-EN ISO 25139:2011 ←","search_zh":"废气 PN-EN ISO 25139:2011 ←","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea44","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metanu (CH4) (z obliczeń)","methodology_en":"Emission of methane (CH4) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metanu (CH4) (z obliczeń)","reference":"PN-EN ISO 25139:2011 ←","norm_bases":["PN-EN ISO 25139:2011 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metanu (CH4) (z obliczeń) PN-EN ISO 25139:2011 ← Gazy odlotowe Emisja metanu (CH4) (z obliczen) PN-EN ISO 25139:2011 ←","categories":["environment"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gases Emission of methane (CH4) (calculated) PN-EN ISO 25139:2011 ←","search_zh":"废气 PN-EN ISO 25139:2011 ←","test_object_zh":"废气"},{"_id":"6a5dc9bef1c10c8ce825ea45","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie:","methodology_en":"AMS calibration (QAL2) for:","parameters":[{"name":"pyłu, SO2, NO, NO2, NOx, CO"},{"name":"O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC"}],"parameters_en":[{"name":"dust, SO2, NO, NO2, NOx, CO"},{"name":"O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie:\nZakres:\npyłu, SO2, NO, NO2, NOx, CO\nO2, CO2, N2O, H2O, HF, HCl, Hg, TVOC","reference":"PN-EN 14181:2015 ←","norm_bases":["PN-EN 14181:2015 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie:\nZakres:\npyłu, SO2, NO, NO2, NOx, CO\nO2, CO2, N2O, H2O, HF, HCl, Hg, TVOC PN-EN 14181:2015 ← Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie:\nZakres:\npylu, SO2, NO, NO2, NOx, CO\nO2, CO2, N2O, H2O, HF, HCl, Hg, TVOC PN-EN 14181:2015 ←","categories":["metrology"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for: dust, SO2, NO, NO2, NOx, CO O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC PN-EN 14181:2015 ←","search_zh":"自动测量系统（AMS） PN-EN 14181:2015 ←","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9bef1c10c8ce825ea46","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie:","methodology_en":"Annual surveillance test (AST) for:","parameters":[{"name":"pyłu, SO2, NO, NO2, NOx, CO"},{"name":"O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC"}],"parameters_en":[{"name":"dust, SO2, NO, NO2, NOx, CO"},{"name":"O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczne badanie kontrolne (AST) w zakresie:\nZakres:\npyłu, SO2, NO, NO2, NOx, CO\nO2, CO2, N2O, H2O, HF, HCl, Hg, TVOC","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie:\nZakres:\npyłu, SO2, NO, NO2, NOx, CO\nO2, CO2, N2O, H2O, HF, HCl, Hg, TVOC PN-EN 14181:2015 Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie:\nZakres:\npylu, SO2, NO, NO2, NOx, CO\nO2, CO2, N2O, H2O, HF, HCl, Hg, TVOC PN-EN 14181:2015","categories":["other"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, SO2, NO, NO2, NOx, CO O2, CO2, N2O, H2O, HF, HCl, Hg, TVOC PN-EN 14181:2015","search_zh":"自动测量系统（AMS） PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9bef1c10c8ce825ea47","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,001 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,001 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994 ←","norm_bases":["PN-Z-04030-7:1994 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,001 – 100) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 ←","categories":["other"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-Z-04030-7:1994 ←","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 100) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-Z-04030-7:1994 ←","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9bef1c10c8ce825ea48","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,0002 – 0,05) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,0002 – 0,05) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,0002 – 0,05) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02 ←","norm_bases":["PN-EN 13284-1:2018-02 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,0002 – 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,0002 – 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 ←","categories":["other"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02 ←","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0002 – 0,05) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02 ←","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9bef1c10c8ce825ea49","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie SO2","methodology_en":"SO2 concentration","parameters":[{"name":"Zakres","range":"(1 – 15000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1 – 15000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"technique_en":"Thoron method","computed":[],"computed_en":[],"activity":"Stężenie SO2\nZakres (1 – 15000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04 ←","norm_bases":["PN-EN 14791:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie SO2\nZakres (1 – 15000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie SO2\nZakres (1 – 15000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 ←","categories":["other"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) SO2 concentration Thoron method Range PN-EN 14791:2017-04 ←","parameters_zh":[{"name":"范围","range":"(1 – 15000) mg/m3"}],"search_zh":"自动测量系统（AMS） SO2 浓度 钍射气法 范围 PN-EN 14791:2017-04 ←","test_object_zh":"自动测量系统（AMS）","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea4a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NO","methodology_en":"NO concentration","parameters":[{"name":"Zakres","range":"(0,7 – 1340) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,7 – 1340) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie NO\nZakres (0,7 – 1340) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04 ←","norm_bases":["PN-EN 14792:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NO\nZakres (0,7 – 1340) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie NO\nZakres (0,7 – 1340) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ←","categories":["other"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NO concentration Chemiluminescence method Range PN-EN 14792:2017-04 ←","parameters_zh":[{"name":"范围","range":"(0,7 – 1340) mg/m3"}],"search_zh":"自动测量系统（AMS） NO 浓度 化学发光法 范围 PN-EN 14792:2017-04 ←","test_object_zh":"自动测量系统（AMS）","technique_zh":"化学发光法","methodology_zh":"NO 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea4b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NO2","methodology_en":"NO2 concentration","parameters":[{"name":"Zakres","range":"(1,1 – 2050) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,1 – 2050) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie NO2\nZakres (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04 ←","norm_bases":["PN-EN 14792:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NO2\nZakres (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie NO2\nZakres (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ←","categories":["other"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NO2 concentration Chemiluminescence method Range PN-EN 14792:2017-04 ←","parameters_zh":[{"name":"范围","range":"(1,1 – 2050) mg/m3"}],"search_zh":"自动测量系统（AMS） NO2 浓度 化学发光法 范围 PN-EN 14792:2017-04 ←","test_object_zh":"自动测量系统（AMS）","technique_zh":"化学发光法","methodology_zh":"NO2 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea4c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NOx","methodology_en":"NOx concentration","parameters":[{"name":"Zakres","range":"(1,1 – 2050) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,1 – 2050) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"technique_en":"Chemiluminescence method","computed":[],"computed_en":[],"activity":"Stężenie NOx\nZakres (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04 ←","norm_bases":["PN-EN 14792:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NOx\nZakres (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie NOx\nZakres (1,1 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 ←","categories":["other"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NOx concentration Chemiluminescence method Range PN-EN 14792:2017-04 ←","parameters_zh":[{"name":"范围","range":"(1,1 – 2050) mg/m3"}],"search_zh":"自动测量系统（AMS） NOx 浓度 化学发光法 范围 PN-EN 14792:2017-04 ←","test_object_zh":"自动测量系统（AMS）","technique_zh":"化学发光法","methodology_zh":"NOx 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea4d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO","methodology_en":"CO concentration","parameters":[{"name":"Zakres","range":"(0,8 - 6250) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,8 - 6250) mg/m3"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"technique_en":"NDIR method","computed":[],"computed_en":[],"activity":"Stężenie CO\nZakres (0,8 - 6250) mg/m3\nMetoda NDIR","reference":"PN-EN 15058:2017-04 ←","norm_bases":["PN-EN 15058:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO\nZakres (0,8 - 6250) mg/m3\nMetoda NDIR PN-EN 15058:2017-04 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie CO\nZakres (0,8 - 6250) mg/m3\nMetoda NDIR PN-EN 15058:2017-04 ←","categories":["other"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO concentration NDIR method Range PN-EN 15058:2017-04 ←","parameters_zh":[{"name":"范围","range":"(0,8 - 6250) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 非分散红外法（NDIR） 范围 PN-EN 15058:2017-04 ←","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO 浓度","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a5dc9bef1c10c8ce825ea4e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie O2","methodology_en":"O2 concentration","parameters":[{"name":"Zakres","range":"(0,1 – 25) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 25) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"technique_en":"Paramagnetic method","computed":[],"computed_en":[],"activity":"Stężenie O2\nZakres (0,1 – 25) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04 ←","norm_bases":["PN-EN 14789:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie O2\nZakres (0,1 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie O2\nZakres (0,1 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 ←","categories":["other"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) O2 concentration Paramagnetic method Range PN-EN 14789:2017-04 ←","parameters_zh":[{"name":"范围","range":"(0,1 – 25) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法 范围 PN-EN 14789:2017-04 ←","test_object_zh":"自动测量系统（AMS）","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea4f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO2","methodology_en":"CO2 concentration","parameters":[{"name":"Zakres","range":"(0,1 – 30) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30) %"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"technique_en":"NDIR method","computed":[],"computed_en":[],"activity":"Stężenie CO2\nZakres (0,1 – 30) %\nMetoda NDIR","reference":"ISO 12039:2019 ←","norm_bases":["ISO 12039:2019 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO2\nZakres (0,1 – 30) %\nMetoda NDIR ISO 12039:2019 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie CO2\nZakres (0,1 – 30) %\nMetoda NDIR ISO 12039:2019 ←","categories":["other"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) CO2 concentration NDIR method Range ISO 12039:2019 ←","parameters_zh":[{"name":"范围","range":"(0,1 – 30) %"}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外法（NDIR） 范围 ISO 12039:2019 ←","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO2 浓度","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a5dc9bef1c10c8ce825ea50","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pary wodnej (H2O)","methodology_en":"Water vapour concentration (H2O)","parameters":[{"name":"Zakres","range":"(23 − 250) mg/m3"},{"name":"Zakres","range":"(3 – 40) %"},{"name":"Zakres","range":"(3,14 − 57)%"}],"parameters_en":[{"name":"Range","range":"(23 − 250) mg/m3"},{"name":"Range","range":"(3 – 40) %"},{"name":"Range","range":"(3,14 − 57)%"}],"technique":"Metoda kondensacyjno- adsorpcyjna; Metoda temperaturowa","techniques":["Metoda kondensacyjno- adsorpcyjna","Metoda temperaturowa"],"technique_en":"Condensation- adsorption method; Temperature method","computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (23 − 250) mg/m3\nZakres (3 – 40) %\nZakres (3,14 − 57)%\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa","reference":"PN-EN 14790:2017-04 ←","norm_bases":["PN-EN 14790:2017-04 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pary wodnej (H2O)\nZakres:\nZakres (23 − 250) mg/m3\nZakres (3 – 40) %\nZakres (3,14 − 57)%\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie pary wodnej (H2O)\nZakres:\nZakres (23 − 250) mg/m3\nZakres (3 – 40) %\nZakres (3,14 − 57)%\nMetoda kondensacyjno- adsorpcyjna; Metoda temperaturowa PN-EN 14790:2017-04 ←","categories":["other"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Water vapour concentration (H2O) Condensation- adsorption method; Temperature method Range Range Range PN-EN 14790:2017-04 ←","parameters_zh":[{"name":"范围","range":"(23 − 250) mg/m3"},{"name":"范围","range":"(3 – 40) %"},{"name":"范围","range":"(3,14 − 57)%"}],"search_zh":"自动测量系统（AMS） 水蒸气浓度（H2O） 范围 范围 范围 PN-EN 14790:2017-04 ←","test_object_zh":"自动测量系统（AMS）","methodology_zh":"水蒸气浓度（H2O）"},{"_id":"6a5dc9bef1c10c8ce825ea51","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie HF","methodology_en":"HF concentration","parameters":[{"name":"Zakres","range":"(0,1 − 200) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,1 − 200) mg/m3"}],"technique":"Metoda z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda z zastosowaniem elektrody jonoselektywnej"],"technique_en":"Method using an ion-selective electrode","computed":[],"computed_en":[],"activity":"Stężenie HF\nZakres (0,1 − 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006 ←","norm_bases":["ISO 15713:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie HF\nZakres (0,1 − 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie HF\nZakres (0,1 − 200) mg/m3\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 ←","categories":["other"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) HF concentration Method using an ion-selective electrode Range ISO 15713:2006 ←","parameters_zh":[{"name":"范围","range":"(0,1 − 200) mg/m3"}],"search_zh":"自动测量系统（AMS） HF 浓度 离子选择电极法 范围 ISO 15713:2006 ←","test_object_zh":"自动测量系统（AMS）","methodology_zh":"HF 浓度","technique_zh":"离子选择电极法"},{"_id":"6a5dc9bef1c10c8ce825ea52","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie HCl","methodology_en":"HCl concentration","parameters":[{"name":"Zakres","range":"(0,1 − 5000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,1 − 5000) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie HCl\nZakres (0,1 − 5000) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011 ←","norm_bases":["PN-EN 1911:2011 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie HCl\nZakres (0,1 − 5000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie HCl\nZakres (0,1 − 5000) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 ←","categories":["other"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) HCl concentration Spectrophotometric method Range PN-EN 1911:2011 ←","parameters_zh":[{"name":"范围","range":"(0,1 − 5000) mg/m3"}],"search_zh":"自动测量系统（AMS） HCl 浓度 分光光度法 范围 PN-EN 1911:2011 ←","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"HCl 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea53","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie rtęci ogólnej","methodology_en":"Total mercury concentration","parameters":[{"name":"Zakres","range":"(0,0033 – 770) μg/m3"}],"parameters_en":[{"name":"Range","range":"(0,0033 – 770) μg/m3"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci ogólnej\nZakres (0,0033 – 770) μg/m3\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13211+AC:2006 ←","norm_bases":["PN-EN 13211+AC:2006 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie rtęci ogólnej\nZakres (0,0033 – 770) μg/m3\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie rteci ogolnej\nZakres (0,0033 – 770) μg/m3\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006 ←","categories":["other"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Total mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 13211+AC:2006 ←","parameters_zh":[{"name":"范围","range":"(0,0033 – 770) μg/m3"}],"search_zh":"自动测量系统（AMS） 总汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 13211+AC:2006 ←","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"自动测量系统（AMS）","methodology_zh":"总汞浓度"},{"_id":"6a5dc9bef1c10c8ce825ea54","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters":[{"name":"Zakres","range":"(0,5 – 1000) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,5 – 1000) mg/m3"}],"technique":"Metoda ciekłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","techniques":["Metoda ciekłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)"],"technique_en":"Continuous measurement method with flame ionization detection (FID)","computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,5 – 1000) mg/m3\nMetoda ciekłego pomiaru z detekcją płomieniowo-jonizacyjną (FID)","reference":"PN-EN 12619:2013-05 ←","norm_bases":["PN-EN 12619:2013-05 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (0,5 – 1000) mg/m3\nMetoda ciekłego pomiaru z detekcją płomieniowo-jonizacyjną (FID) PN-EN 12619:2013-05 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (0,5 – 1000) mg/m3\nMetoda cieklego pomiaru z detekcja plomieniowo-jonizacyjna (FID) PN-EN 12619:2013-05 ←","categories":["other"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous measurement method with flame ionization detection (FID) Range PN-EN 12619:2013-05 ←","parameters_zh":[{"name":"范围","range":"(0,5 – 1000) mg/m3"}],"search_zh":"自动测量系统（AMS） 以总气态有机碳表示的气态与蒸气态有机物浓度 范围 PN-EN 12619:2013-05 ←","test_object_zh":"自动测量系统（AMS）","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度"},{"_id":"6a5dc9bef1c10c8ce825ea55","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: NH3, N2O, CH2O","methodology_en":"AMS calibration (QAL2) for: NH3, N2O, CH2O","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Kalibracja AMS (QAL2) w zakresie: NH3, N2O, CH2O","reference":"PN-EN 14181:2015 ←","norm_bases":["PN-EN 14181:2015 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: NH3, N2O, CH2O PN-EN 14181:2015 ← Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: NH3, N2O, CH2O PN-EN 14181:2015 ←","categories":["metrology"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for: NH3, N2O, CH2O PN-EN 14181:2015 ←","search_zh":"自动测量系统（AMS） PN-EN 14181:2015 ←","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9bef1c10c8ce825ea56","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie: NH3, N2O, CH2O","methodology_en":"Annual surveillance test (AST) for: NH3, N2O, CH2O","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczne badanie kontrolne (AST) w zakresie: NH3, N2O, CH2O","reference":"PN-EN 14181:2015 ←","norm_bases":["PN-EN 14181:2015 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: NH3, N2O, CH2O PN-EN 14181:2015 ← Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: NH3, N2O, CH2O PN-EN 14181:2015 ←","categories":["other"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for: NH3, N2O, CH2O PN-EN 14181:2015 ←","search_zh":"自动测量系统（AMS） PN-EN 14181:2015 ←","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5dc9bef1c10c8ce825ea57","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NH3","methodology_en":"NH3 concentration","parameters":[{"name":"Zakres","range":"(0,38 − 38) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,38 − 38) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)"],"technique_en":"Fourier transform infrared spectroscopy (FTIR)","computed":[],"computed_en":[],"activity":"Stężenie NH3\nZakres (0,38 − 38) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","reference":"LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","norm_bases":["LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","ISO 17179:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NH3\nZakres (0,38 − 38) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016 Automatyczne Systemy, Monitoringu (AMS) Stezenie NH3\nZakres (0,38 − 38) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR) LBS-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","categories":["other"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) NH3 concentration Fourier transform infrared spectroscopy (FTIR) Range LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","parameters_zh":[{"name":"范围","range":"(0,38 − 38) mg/m3"}],"search_zh":"自动测量系统（AMS） NH3 浓度 傅里叶变换红外光谱法（FTIR） 范围 LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. | ISO 17179:2016","test_object_zh":"自动测量系统（AMS）","methodology_zh":"NH3 浓度","technique_zh":"傅里叶变换红外光谱法（FTIR）"},{"_id":"6a5dc9bef1c10c8ce825ea58","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie N2O","methodology_en":"N2O concentration","parameters":[{"name":"Zakres","range":"(1,97 – 3900) mg/m3"}],"parameters_en":[{"name":"Range","range":"(1,97 – 3900) mg/m3"}],"technique":"Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","techniques":["Metoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)"],"technique_en":"Fourier transform infrared spectroscopy (FTIR)","computed":[],"computed_en":[],"activity":"Stężenie N2O\nZakres (1,97 – 3900) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR)","reference":"LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","norm_bases":["LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie N2O\nZakres (1,97 – 3900) mg/m3\nMetoda spektroskopii w podczerwieni z transformacją Fouriera (FTIR) LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r. Automatyczne Systemy, Monitoringu (AMS) Stezenie N2O\nZakres (1,97 – 3900) mg/m3\nMetoda spektroskopii w podczerwieni z transformacja Fouriera (FTIR) LBS-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","categories":["other"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) N2O concentration Fourier transform infrared spectroscopy (FTIR) Range LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","parameters_zh":[{"name":"范围","range":"(1,97 – 3900) mg/m3"}],"search_zh":"自动测量系统（AMS） N2O 浓度 傅里叶变换红外光谱法（FTIR） 范围 LBŚ-PB-23 ← wydanie 4 z dnia 13.07.2020 r.","test_object_zh":"自动测量系统（AMS）","technique_zh":"傅里叶变换红外光谱法（FTIR）","methodology_zh":"N2O 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea59","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie amoniaku","methodology_en":"Ammonia concentration","parameters":[{"name":"Zakres","range":"(0,06 – 629) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,06 – 629) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie amoniaku\nZakres (0,06 – 629) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie amoniaku\nZakres (0,06 – 629) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Automatyczne Systemy, Monitoringu (AMS) Stezenie amoniaku\nZakres (0,06 – 629) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Ammonia concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,06 – 629) mg/m3"}],"search_zh":"自动测量系统（AMS） 氨浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氨浓度"},{"_id":"6a5dc9bef1c10c8ce825ea5a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie N2O","methodology_en":"N2O concentration","parameters":[{"name":"Zakres","range":"(0,8 – 980) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,8 – 980) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"technique_en":"Non-dispersive infrared spectrometry (NDIR)","computed":[],"computed_en":[],"activity":"Stężenie N2O\nZakres (0,8 – 980) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 21258:2010 ←","norm_bases":["PN-EN 21258:2010 ←"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie N2O\nZakres (0,8 – 980) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 21258:2010 ← Automatyczne Systemy, Monitoringu (AMS) Stezenie N2O\nZakres (0,8 – 980) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 21258:2010 ←","categories":["other"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) N2O concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN 21258:2010 ←","parameters_zh":[{"name":"范围","range":"(0,8 – 980) mg/m3"}],"search_zh":"自动测量系统（AMS） N2O 浓度 非分散红外光谱法（NDIR） 范围 PN-EN 21258:2010 ←","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a5dc9bef1c10c8ce825ea5b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie formaldehydu","methodology_en":"Formaldehyde concentration","parameters":[{"name":"Zakres","range":"(0,035 – 700) mg/m3"}],"parameters_en":[{"name":"Range","range":"(0,035 – 700) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie formaldehydu\nZakres (0,035 – 700) mg/m3\nMetoda spektrofotometryczna","reference":"CEN/TS 17638:2021","norm_bases":["CEN/TS 17638:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie formaldehydu\nZakres (0,035 – 700) mg/m3\nMetoda spektrofotometryczna CEN/TS 17638:2021 Automatyczne Systemy, Monitoringu (AMS) Stezenie formaldehydu\nZakres (0,035 – 700) mg/m3\nMetoda spektrofotometryczna CEN/TS 17638:2021","categories":["other"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Automated Measuring Systems (AMS) Formaldehyde concentration Spectrophotometric method Range CEN/TS 17638:2021","parameters_zh":[{"name":"范围","range":"(0,035 – 700) mg/m3"}],"search_zh":"自动测量系统（AMS） 甲醛浓度 分光光度法 范围 CEN/TS 17638:2021","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"甲醛浓度"},{"_id":"6a5dc9bef1c10c8ce825ea5c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Stężenie pyłu","methodology_en":"Dust concentration","parameters":[{"name":"Zakres","range":"(0,0002 – 100) g/m3"}],"parameters_en":[{"name":"Range","range":"(0,0002 – 100) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłu\nZakres (0,0002 – 100) g/m3\nMetoda grawimetryczna","reference":"PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-87/M-34129:1987 ← – metoda A","PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Stężenie pyłu\nZakres (0,0002 – 100) g/m3\nMetoda grawimetryczna PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Urzadzenia odpylajace gazy odlotowe Stezenie pylu\nZakres (0,0002 – 100) g/m3\nMetoda grawimetryczna PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["other"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gas dedusting equipment Dust concentration Gravimetric method Range PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,0002 – 100) g/m3"}],"search_zh":"废气除尘设备 粉尘浓度 重量法 范围 PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气除尘设备"},{"_id":"6a5dc9bef1c10c8ce825ea5d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Skuteczność odpylania (z obliczeń)","methodology_en":"Dust removal efficiency (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność odpylania (z obliczeń)","reference":"PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-87/M-34129:1987 ← – metoda A","PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania (z obliczeń) PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania (z obliczen) PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["other"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste gas dedusting equipment Dust removal efficiency (calculated) PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","search_zh":"废气除尘设备 除尘效率（由计算得出） PN-87/M-34129:1987 ← – metoda A | PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_zh":"废气除尘设备","methodology_zh":"除尘效率（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea5e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry","test_object_en":"General environment – waste gas samples collected on filters","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,01 – 0,125) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,01 – 0,125) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,01 – 0,125) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13211+AC:2006*","norm_bases":["PN-EN 13211+AC:2006*"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane na filtry Zawartość rtęci\nZakres (0,01 – 0,125) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006* Srodowisko ogolne – probki gazow odlotowych pobrane na filtry Zawartosc rteci\nZakres (0,01 – 0,125) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006*","categories":["environment"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – waste gas samples collected on filters Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 13211+AC:2006*","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,01 – 0,125) μg w próbce"}],"search_zh":"一般环境 — 用滤膜采集的废气样品 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 13211+AC:2006*","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"一般环境 — 用滤膜采集的废气样品"},{"_id":"6a5dc9bef1c10c8ce825ea5f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego","test_object_en":"General environment – waste gas samples collected into absorbing solution","methodology":"Zawartość rtęci","methodology_en":"Mercury content","parameters":[{"name":"Zakres","range":"(0,007 – 87,5) μg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,007 – 87,5) μg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Zawartość rtęci\nZakres (0,007 – 87,5) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 13211+AC:2006*","norm_bases":["PN-EN 13211+AC:2006*"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego Zawartość rtęci\nZakres (0,007 – 87,5) μg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006* Srodowisko ogolne – probki gazow odlotowych pobrane do roztworu pochlaniajacego Zawartosc rteci\nZakres (0,007 – 87,5) μg w probce\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 13211+AC:2006*","categories":["environment"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – waste gas samples collected into absorbing solution Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 13211+AC:2006*","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,007 – 87,5) μg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 13211+AC:2006*","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9bef1c10c8ce825ea60","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego","test_object_en":"General environment – waste gas samples collected into absorbing solution","methodology":"Zawartość chlorowodoru","methodology_en":"Hydrogen chloride content","parameters":[{"name":"Zakres","range":"(0,02 – 300) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,02 – 300) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość chlorowodoru\nZakres (0,02 – 300) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011*","norm_bases":["PN-EN 1911:2011*"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego Zawartość chlorowodoru\nZakres (0,02 – 300) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011* Srodowisko ogolne – probki gazow odlotowych pobrane do roztworu pochlaniajacego Zawartosc chlorowodoru\nZakres (0,02 – 300) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011*","categories":["environment"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – waste gas samples collected into absorbing solution Hydrogen chloride content Spectrophotometric method Range PN-EN 1911:2011*","parameters_zh":[{"name":"范围","range":"(0,02 – 300) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氯化氢含量 分光光度法 范围 PN-EN 1911:2011*","technique_zh":"分光光度法","methodology_zh":"氯化氢含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9bef1c10c8ce825ea61","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego","test_object_en":"General environment – waste gas samples collected into absorbing solution","methodology":"Zawartość fluorowodoru","methodology_en":"Hydrogen fluoride content","parameters":[{"name":"Zakres","range":"(0,01 – 20) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,01 – 20) mg w próbce"}],"technique":"Metoda z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda z zastosowaniem elektrody jonoselektywnej"],"technique_en":"Method using an ion-selective electrode","computed":[],"computed_en":[],"activity":"Zawartość fluorowodoru\nZakres (0,01 – 20) mg w próbce\nMetoda z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006*","norm_bases":["ISO 15713:2006*"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego Zawartość fluorowodoru\nZakres (0,01 – 20) mg w próbce\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006* Srodowisko ogolne – probki gazow odlotowych pobrane do roztworu pochlaniajacego Zawartosc fluorowodoru\nZakres (0,01 – 20) mg w probce\nMetoda z zastosowaniem elektrody jonoselektywnej ISO 15713:2006*","categories":["environment"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – waste gas samples collected into absorbing solution Hydrogen fluoride content Method using an ion-selective electrode Range ISO 15713:2006*","parameters_zh":[{"name":"范围","range":"(0,01 – 20) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氟化氢含量 离子选择电极法 范围 ISO 15713:2006*","methodology_zh":"氟化氢含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品","technique_zh":"离子选择电极法"},{"_id":"6a5dc9bef1c10c8ce825ea62","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego","test_object_en":"General environment – waste gas samples collected into absorbing solution","methodology":"Zawartość amoniaku","methodology_en":"Ammonia content","parameters":[{"name":"Zakres","range":"(0,095 – 236) mg/l w próbce"}],"parameters_en":[{"name":"Range","range":"(0,095 – 236) mg/l w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość amoniaku\nZakres (0,095 – 236) mg/l w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 21877:2020-03","norm_bases":["PN-EN 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego Zawartość amoniaku\nZakres (0,095 – 236) mg/l w próbce\nMetoda spektrofotometryczna PN-EN 21877:2020-03 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworu pochlaniajacego Zawartosc amoniaku\nZakres (0,095 – 236) mg/l w probce\nMetoda spektrofotometryczna PN-EN 21877:2020-03","categories":["environment"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – waste gas samples collected into absorbing solution Ammonia content Spectrophotometric method Range PN-EN 21877:2020-03","parameters_zh":[{"name":"范围","range":"(0,095 – 236) mg/l w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 氨含量 分光光度法 范围 PN-EN 21877:2020-03","technique_zh":"分光光度法","methodology_zh":"氨含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9bef1c10c8ce825ea63","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego","test_object_en":"General environment – waste gas samples collected into absorbing solution","methodology":"Zawartość formaldehydu","methodology_en":"Formaldehyde content","parameters":[{"name":"Zakres","range":"(0,0042 – 42) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,0042 – 42) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość formaldehydu\nZakres (0,0042 – 42) mg w próbce\nMetoda spektrofotometryczna","reference":"CEN/TS 17638:2021","norm_bases":["CEN/TS 17638:2021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego Zawartość formaldehydu\nZakres (0,0042 – 42) mg w próbce\nMetoda spektrofotometryczna CEN/TS 17638:2021 Srodowisko ogolne – probki gazow odlotowych pobrane do roztworu pochlaniajacego Zawartosc formaldehydu\nZakres (0,0042 – 42) mg w probce\nMetoda spektrofotometryczna CEN/TS 17638:2021","categories":["environment"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – waste gas samples collected into absorbing solution Formaldehyde content Spectrophotometric method Range CEN/TS 17638:2021","parameters_zh":[{"name":"范围","range":"(0,0042 – 42) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 甲醛含量 分光光度法 范围 CEN/TS 17638:2021","technique_zh":"分光光度法","methodology_zh":"甲醛含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9bef1c10c8ce825ea64","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego","test_object_en":"General environment – waste gas samples collected into absorbing solution","methodology":"Zawartość siarkowodoru","methodology_en":"Hydrogen sulphide content","parameters":[{"name":"Zakres","range":"(0,01 – 11,2) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,01 – 11,2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość siarkowodoru\nZakres (0,01 – 11,2) mg w próbce\nMetoda spektrofotometryczna","reference":"LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","norm_bases":["LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – próbki gazów odlotowych pobrane do roztworu pochłaniającego Zawartość siarkowodoru\nZakres (0,01 – 11,2) mg w próbce\nMetoda spektrofotometryczna LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r. Srodowisko ogolne – probki gazow odlotowych pobrane do roztworu pochlaniajacego Zawartosc siarkowodoru\nZakres (0,01 – 11,2) mg w probce\nMetoda spektrofotometryczna LBS-PB-25 wydanie 1 z dnia 15.03.2024 r.","categories":["environment"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment – waste gas samples collected into absorbing solution Hydrogen sulphide content Spectrophotometric method Range LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","parameters_zh":[{"name":"范围","range":"(0,01 – 11,2) mg w próbce"}],"search_zh":"一般环境 － 采集于吸收液中的排放气体样品 硫化氢含量 分光光度法 范围 LBŚ-PB-25 wydanie 1 z dnia 15.03.2024 r.","technique_zh":"分光光度法","methodology_zh":"硫化氢含量","test_object_zh":"一般环境 － 采集于吸收液中的排放气体样品"},{"_id":"6a5dc9bef1c10c8ce825ea65","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(26 – 136) dB"}],"parameters_en":[{"name":"Range","range":"(26 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (26 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F","norm_bases":["Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (26 – 136) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (26 – 136) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 rozporzadzenia ← Ministra Klimatu i Srodowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wylaczeniem pkt. EII1 i pkt F","categories":["environment"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(26 – 136) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9bef1c10c8ce825ea66","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F","norm_bases":["Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 rozporzadzenia ← Ministra Klimatu i Srodowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wylaczeniem pkt. EII1 i pkt F","categories":["environment"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 rozporządzenia ← Ministra Klimatu i Środowiska z dnia 07.09.2021 (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. EII1 i pkt F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5dc9bef1c10c8ce825ea67","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","test_object_en":"Machinery and equipment – noise","methodology":"Równoważny poziom dźwięku A","methodology_en":"A-weighted equivalent sound pressure level","parameters":[{"name":"Zakres","range":"(26 − 136) dB"}],"parameters_en":[{"name":"Range","range":"(26 − 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A\nZakres (26 − 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia – hałas Równoważny poziom dźwięku A\nZakres (26 − 136) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Rownowazny poziom dzwieku A\nZakres (26 − 136) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Machinery and equipment – noise A-weighted equivalent sound pressure level Direct measurement method Range PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(26 − 136) dB"}],"search_zh":"机器与设备 – 噪声 A 计权等效声级 直接测量法 范围 PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声"},{"_id":"6a5dc9bef1c10c8ce825ea68","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","test_object_en":"Machinery and equipment – noise","methodology":"Poziom mocy akustycznej (z obliczeń)","methodology_en":"Sound power level (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3746:2011 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a5dc9bef1c10c8ce825ea69","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(26 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 – 140) dB"}],"parameters_en":[{"name":"Range","range":"(26 – 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (26 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (26 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (26 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (40 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - p.10 i strategie 3 - p. 11","categories":["environment"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(26 – 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 – 140) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9bef1c10c8ce825ea6a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - p.10 i strategie 3 - p. 11","categories":["environment"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作环境 − 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - p.10 i strategię 3 - p. 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5dc9bef1c10c8ce825ea6b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie","test_object_en":"Workplace environment − lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(0,5 – 9 750) lx"}],"parameters_en":[{"name":"Range","range":"(0,5 – 9 750) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 9 750) lx\nMetoda pomiarowa bezpośrednia","reference":"LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","norm_bases":["LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r.","PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − oświetlenie Natężenie oświetlenia\nZakres (0,5 – 9 750) lx\nMetoda pomiarowa bezpośrednia LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03 Srodowisko pracy − oswietlenie Natezenie oswietlenia\nZakres (0,5 – 9 750) lx\nMetoda pomiarowa bezposrednia LBS-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","categories":["environment"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − lighting Illuminance Direct measurement method Range LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 9 750) lx"}],"search_zh":"工作环境 － 照明 照度 直接测量法 范围 LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作环境 － 照明"},{"_id":"6a5dc9bef1c10c8ce825ea6c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie","test_object_en":"Workplace environment − lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","norm_bases":["LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r.","PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − oświetlenie Równomierność oświetlenia (z obliczeń) LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03 Srodowisko pracy − oswietlenie Rownomiernosc oswietlenia (z obliczen) LBS-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","categories":["environment"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − lighting Illuminance uniformity (calculated) LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 照明 照度均匀度（计算值） LBŚ-PB-14 wydanie 4 z dnia 30.06.2025 r. | PN-83/E-04040.03","test_object_zh":"工作环境 － 照明"},{"_id":"6a5dc9bef1c10c8ce825ea6d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment − whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyśpieszenie drgań","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters":[{"name":"Zakres","range":"(0,053 – 100) m/s2"}],"parameters_en":[{"name":"Range","range":"(0,053 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyśpieszenie drgań\nZakres (0,053 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyśpieszenie drgań\nZakres (0,053 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,053 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","parameters_zh":[{"name":"范围","range":"(0,053 – 100) m/s2"}],"search_zh":"工作场所环境 − 全身振动 频率计权有效振动加速度 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 全身振动","methodology_zh":"频率计权有效振动加速度"},{"_id":"6a5dc9bef1c10c8ce825ea6e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment − whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8 godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8 godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1,4awx, 1,4awy, awz) (calculated) PN-EN 14253+A1:2011","search_zh":"工作场所环境 − 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 − 全身振动"},{"_id":"6a5dc9bef1c10c8ce825ea6f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","test_object_en":"Workplace environment - moderate microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 – 50) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) 0C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,20 – 5) m/s"}],"parameters_en":[{"name":"Range","range":"(10 – 50) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) 0C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,20 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) 0C\nTemperatura poczernionej kuli\nZakres (10 – 50) 0C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,20 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 50) 0C\nTemperatura poczernionej kuli\nZakres (10 – 50) 0C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,20 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 50) 0C\nTemperatura poczernionej kuli\nZakres (10 – 50) 0C\nWilgotnosc powietrza\nZakres (25 – 75) %\nPredkosc powietrza\nZakres (0,20 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) 0C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,20 – 5) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5dc9bef1c10c8ce825ea70","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","test_object_en":"Workplace environment - moderate microclimate","methodology":"Wskaźnik PMV i PPD (z obliczeń)","methodology_en":"PMV and PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV i PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV i PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV i PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - moderate microclimate PMV and PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","search_zh":"工作场所环境 — 中等微气候 PMV 与 PPD 指数（由计算得出） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候","methodology_zh":"PMV 与 PPD 指数（由计算得出）"},{"_id":"6a5dc9bef1c10c8ce825ea71","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","test_object_en":"Workplace environment - hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10 – 50) 0C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 50) 0C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) 0C"}],"parameters_en":[{"name":"Range","range":"(10 – 50) 0C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 50) 0C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) 0C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) 0C\nTemperatura wilgotna naturalna\nZakres (10 – 50) 0C\nTemperatura poczernionej kuli\nZakres (10 – 50) 0C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 50) 0C\nTemperatura wilgotna naturalna\nZakres (10 – 50) 0C\nTemperatura poczernionej kuli\nZakres (10 – 50) 0C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 50) 0C\nTemperatura wilgotna naturalna\nZakres (10 – 50) 0C\nTemperatura poczernionej kuli\nZakres (10 – 50) 0C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) 0C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 50) 0C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) 0C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9bef1c10c8ce825ea72","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","test_object_en":"Workplace environment - hot microclimate","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","methodology_en":"WBGT index, WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01","PN-EN ISO 7243:2018-01/Ap2:2020-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","categories":["environment"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9bef1c10c8ce825ea73","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego:","methodology_en":"Sampling for assessment of occupational exposure:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"}],"parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sampling for assessment of occupational exposure: Personal dosimetry method dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"}],"search_zh":"工作环境 − 空气 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 有机物质，包括 可吸入组分 无机物质，包括 可吸入组分 呼吸性组分 胸腔组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bef1c10c8ce825ea74","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego:","methodology_en":"Sampling for assessment of occupational exposure:","parameters":[{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"}],"parameters_en":[{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"technique_en":"Stationary method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sampling for assessment of occupational exposure: Stationary method inorganic substances, including inhalable fraction respirable fraction thoracic fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","parameters_zh":[{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"}],"search_zh":"工作环境 − 空气 定点测定法 无机物质，包括 可吸入组分 呼吸性组分 胸腔组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作环境 − 空气","technique_zh":"定点测定法"},{"_id":"6a5dc9bef1c10c8ce825ea75","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bef1c10c8ce825ea76","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna","methodology_en":"Concentration of harmful dust agents - inhalable fraction","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,08 – 81,6) mg/m3"},{"name":"Zakres","range":"(0,06 – 2,45) mg w próbce"}],"parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,08 – 81,6) mg/m3"},{"name":"Range","range":"(0,06 – 2,45) mg w próbce"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,08 – 81,6) mg/m3\nZakres (0,06 – 2,45) mg w próbce\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych - frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,08 – 81,6) mg/m3\nZakres (0,06 – 2,45) mg w próbce\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych - frakcja wdychalna\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,08 – 81,6) mg/m3\nZakres (0,06 – 2,45) mg w probce\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents - inhalable fraction Gravimetric method Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,08 – 81,6) mg/m3"},{"name":"范围","range":"(0,06 – 2,45) mg w próbce"}],"search_zh":"工作环境 − 空气 重量法 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bef1c10c8ce825ea77","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna","methodology_en":"Concentration of harmful dust agents - respirable fraction","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,05 – 43,8) mg/m3"},{"name":"Zakres","range":"(0,05 – 5,0) mg w próbce"}],"parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,05 – 43,8) mg/m3"},{"name":"Range","range":"(0,05 – 5,0) mg w próbce"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,05 – 43,8) mg/m3\nZakres (0,05 – 5,0) mg w próbce\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,05 – 43,8) mg/m3\nZakres (0,05 – 5,0) mg w próbce\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych - frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,05 – 43,8) mg/m3\nZakres (0,05 – 5,0) mg w probce\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of harmful dust agents - respirable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,05 – 43,8) mg/m3"},{"name":"范围","range":"(0,05 – 5,0) mg w próbce"}],"search_zh":"工作环境 − 空气 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bef1c10c8ce825ea78","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych","methodology_en":"Concentration of highly refined mineral oils excluding metalworking fluids","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,42 – 22,2) mg/m3"}],"parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,42 – 22,2) mg/m3"}],"technique":"Metoda spektrofotometrii UV","techniques":["Metoda spektrofotometrii UV"],"technique_en":"UV spectrophotometry method","computed":[],"computed_en":[],"activity":"Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,42 – 22,2) mg/m3\nMetoda spektrofotometrii UV","reference":"PN-Z-04108-6:2006+Az1:2009","norm_bases":["PN-Z-04108-6:2006+Az1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nfrakcja wdychalna\nZakres (0,42 – 22,2) mg/m3\nMetoda spektrofotometrii UV PN-Z-04108-6:2006+Az1:2009 Srodowisko pracy − powietrze Stezenie olejow mineralnych wysokorafinowanych z wylaczeniem cieczy obrobkowych\nZakres:\nfrakcja wdychalna\nZakres (0,42 – 22,2) mg/m3\nMetoda spektrofotometrii UV PN-Z-04108-6:2006+Az1:2009","categories":["environment","petro"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration of highly refined mineral oils excluding metalworking fluids UV spectrophotometry method inhalable fraction Range PN-Z-04108-6:2006+Az1:2009","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,42 – 22,2) mg/m3"}],"search_zh":"工作环境 − 空气 可吸入组分 范围 PN-Z-04108-6:2006+Az1:2009","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bef1c10c8ce825ea79","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie tlenku węgla","methodology_en":"Carbon monoxide concentration","parameters":[{"name":"Zakres","range":"(2,3 – 250) mg/m3"},{"name":"Zakres","range":"(2,00 – 215) ppm"}],"parameters_en":[{"name":"Range","range":"(2,3 – 250) mg/m3"},{"name":"Range","range":"(2,00 – 215) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 250) mg/m3\nZakres (2,00 – 215) ppm\nMetoda elektrochemiczna","reference":"LBŚ-PB-12 wydanie 4 z dnia 30.06.2025 r.","norm_bases":["LBŚ-PB-12 wydanie 4 z dnia 30.06.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 250) mg/m3\nZakres (2,00 – 215) ppm\nMetoda elektrochemiczna LBŚ-PB-12 wydanie 4 z dnia 30.06.2025 r. Srodowisko pracy − powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 250) mg/m3\nZakres (2,00 – 215) ppm\nMetoda elektrochemiczna LBS-PB-12 wydanie 4 z dnia 30.06.2025 r.","categories":["environment"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Carbon monoxide concentration Electrochemical method Range Range LBŚ-PB-12 wydanie 4 z dnia 30.06.2025 r.","parameters_zh":[{"name":"范围","range":"(2,3 – 250) mg/m3"},{"name":"范围","range":"(2,00 – 215) ppm"}],"search_zh":"工作环境 − 空气 一氧化碳浓度 电化学法 范围 范围 LBŚ-PB-12 wydanie 4 z dnia 30.06.2025 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a5dc9bef1c10c8ce825ea7a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie tlenku azotu","methodology_en":"Nitrogen oxide concentration","parameters":[{"name":"Zakres","range":"(0,012 – 11,56) mg/m3"},{"name":"Zakres","range":"(0,0096 – 9,28) ppm"}],"parameters_en":[{"name":"Range","range":"(0,012 – 11,56) mg/m3"},{"name":"Range","range":"(0,0096 – 9,28) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu\nZakres:\nZakres (0,012 – 11,56) mg/m3\nZakres (0,0096 – 9,28) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie tlenku azotu\nZakres:\nZakres (0,012 – 11,56) mg/m3\nZakres (0,0096 – 9,28) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie tlenku azotu\nZakres:\nZakres (0,012 – 11,56) mg/m3\nZakres (0,0096 – 9,28) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Nitrogen oxide concentration Spectrophotometric method Range Range PN-Z-04009-11:2008","parameters_zh":[{"name":"范围","range":"(0,012 – 11,56) mg/m3"},{"name":"范围","range":"(0,0096 – 9,28) ppm"}],"search_zh":"工作环境 − 空气 一氧化氮浓度 分光光度法 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"一氧化氮浓度"},{"_id":"6a5dc9bef1c10c8ce825ea7b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie ditlenku azotu","methodology_en":"Nitrogen dioxide concentration","parameters":[{"name":"Zakres","range":"(0,018 – 17,78) mg/m3"},{"name":"Zakres","range":"(0,0094 – 9,31) ppm"}],"parameters_en":[{"name":"Range","range":"(0,018 – 17,78) mg/m3"},{"name":"Range","range":"(0,0094 – 9,31) ppm"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ditlenku azotu\nZakres:\nZakres (0,018 – 17,78) mg/m3\nZakres (0,0094 – 9,31) ppm\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie ditlenku azotu\nZakres:\nZakres (0,018 – 17,78) mg/m3\nZakres (0,0094 – 9,31) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy − powietrze Stezenie ditlenku azotu\nZakres:\nZakres (0,018 – 17,78) mg/m3\nZakres (0,0094 – 9,31) ppm\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Nitrogen dioxide concentration Spectrophotometric method Range Range PN-Z-04009-11:2008","parameters_zh":[{"name":"范围","range":"(0,018 – 17,78) mg/m3"},{"name":"范围","range":"(0,0094 – 9,31) ppm"}],"search_zh":"工作环境 − 空气 二氧化氮浓度 分光光度法 范围 范围 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"二氧化氮浓度"},{"_id":"6a5dc9bef1c10c8ce825ea7c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie/zawartość chlorowodoru","methodology_en":"Hydrogen chloride concentration/content","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) mg/m3"},{"name":"Zakres","range":"(0,2 – 20,0) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50,0) mg/m3"},{"name":"Range","range":"(0,2 – 20,0) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 – 50,0) mg/m3\nZakres (0,2 – 20,0) mg w próbce\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 – 50,0) mg/m3\nZakres (0,2 – 20,0) mg w próbce\nMetoda turbidymetryczna PN-Z-04450:2014-08 Srodowisko pracy − powietrze Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,5 – 50,0) mg/m3\nZakres (0,2 – 20,0) mg w probce\nMetoda turbidymetryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Hydrogen chloride concentration/content Turbidimetric method Range Range PN-Z-04450:2014-08","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) mg/m3"},{"name":"范围","range":"(0,2 – 20,0) mg w próbce"}],"search_zh":"工作环境 − 空气 氯化氢的浓度/含量 浊度法 范围 范围 PN-Z-04450:2014-08","test_object_zh":"工作环境 − 空气","technique_zh":"浊度法","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a5dc9bef1c10c8ce825ea7d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie/zawartość ditlenku siarki","methodology_en":"Sulphur dioxide concentration/content","parameters":[{"name":"Zakres","range":"(0,13 − 6,40) mg/m3"},{"name":"Zakres","range":"(0,049 – 2,41) ppm"},{"name":"Zakres","range":"(0,0032 – 0,064) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(0,13 − 6,40) mg/m3"},{"name":"Range","range":"(0,049 – 2,41) ppm"},{"name":"Range","range":"(0,0032 – 0,064) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,13 − 6,40) mg/m3\nZakres (0,049 – 2,41) ppm\nZakres (0,0032 – 0,064) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996+Ap1:2001","norm_bases":["PN-Z-04015-12:1996+Ap1:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,13 − 6,40) mg/m3\nZakres (0,049 – 2,41) ppm\nZakres (0,0032 – 0,064) mg w próbce\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001 Srodowisko pracy − powietrze Stezenie/zawartosc ditlenku siarki\nZakres:\nZakres (0,13 − 6,40) mg/m3\nZakres (0,049 – 2,41) ppm\nZakres (0,0032 – 0,064) mg w probce\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001","categories":["environment"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Sulphur dioxide concentration/content Spectrophotometric method Range Range Range PN-Z-04015-12:1996+Ap1:2001","parameters_zh":[{"name":"范围","range":"(0,13 − 6,40) mg/m3"},{"name":"范围","range":"(0,049 – 2,41) ppm"},{"name":"范围","range":"(0,0032 – 0,064) mg w próbce"}],"search_zh":"工作环境 − 空气 二氧化硫的浓度/含量 分光光度法 范围 范围 范围 PN-Z-04015-12:1996+Ap1:2001","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"二氧化硫的浓度/含量"},{"_id":"6a5dc9bef1c10c8ce825ea7e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie/zawartość amoniaku","methodology_en":"Ammonia concentration/content","parameters":[{"name":"Zakres","range":"(1,3 – 60) mg/m3"},{"name":"Zakres","range":"(0,02 – 0,2) mg w próbce"}],"parameters_en":[{"name":"Range","range":"(1,3 – 60) mg/m3"},{"name":"Range","range":"(0,02 – 0,2) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (1,3 – 60) mg/m3\nZakres (0,02 – 0,2) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie/zawartość amoniaku\nZakres:\nZakres (1,3 – 60) mg/m3\nZakres (0,02 – 0,2) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy − powietrze Stezenie/zawartosc amoniaku\nZakres:\nZakres (1,3 – 60) mg/m3\nZakres (0,02 – 0,2) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Ammonia concentration/content Spectrophotometric method Range Range PN-71/Z-04041","parameters_zh":[{"name":"范围","range":"(1,3 – 60) mg/m3"},{"name":"范围","range":"(0,02 – 0,2) mg w próbce"}],"search_zh":"工作环境 − 空气 氨浓度/含量 分光光度法 范围 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氨浓度/含量"},{"_id":"6a5dc9bef1c10c8ce825ea7f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie / zawartość krzemionki krystalicznej - kwarc; krystobalit","methodology_en":"Concentration / content of crystalline silica - quartz; cristobalite","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0093 – 0,58) mg/m3"},{"name":"Zakres","range":"(0,01 – 0,4) mg w próbce"},{"name":"Fouriera (FT-IR)"}],"parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,0093 – 0,58) mg/m3"},{"name":"Range","range":"(0,01 – 0,4) mg w próbce"},{"name":"Fourier (FT-IR)"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją","techniques":["Metoda spektrometrii w podczerwieni z transformacją"],"technique_en":"Infrared spectrometry with transform","computed":[],"computed_en":[],"activity":"Stężenie / zawartość krzemionki krystalicznej - kwarc; krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,0093 – 0,58) mg/m3\nZakres (0,01 – 0,4) mg w próbce\nFouriera (FT-IR)\nMetoda spektrometrii w podczerwieni z transformacją","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie / zawartość krzemionki krystalicznej - kwarc; krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,0093 – 0,58) mg/m3\nZakres (0,01 – 0,4) mg w próbce\nFouriera (FT-IR)\nMetoda spektrometrii w podczerwieni z transformacją Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130 Srodowisko pracy − powietrze Stezenie / zawartosc krzemionki krystalicznej - kwarc; krystobalit\nZakres:\nfrakcja respirabilna\nZakres (0,0093 – 0,58) mg/m3\nZakres (0,01 – 0,4) mg w probce\nFouriera (FT-IR)\nMetoda spektrometrii w podczerwieni z transformacja Podstawy i Metody Oceny Srodowiska Pracy 2012, nr 4(74) s. 117-130","categories":["environment"],"row_index":132,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment − air Concentration / content of crystalline silica - quartz; cristobalite Infrared spectrometry with transform respirable fraction Range Range Fourier (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0093 – 0,58) mg/m3"},{"name":"范围","range":"(0,01 – 0,4) mg w próbce"},{"name":"傅里叶（FT-IR）"}],"search_zh":"工作环境 − 空气 呼吸性组分 范围 范围 傅里叶（FT-IR） Podstawy i Metody Oceny Środowiska Pracy 2012, nr 4(74) s. 117-130","test_object_zh":"工作环境 − 空气"},{"_id":"6a5dc9bef1c10c8ce825ea80","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters":[{"name":"Zakres","range":"(0,5 – 50) °C"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) °C","reference":"PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","norm_bases":["PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.1.2, 6.2, 6.3","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) °C PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,5 – 50) °C PN-ISO 5667-11:2017-10 z wyl. pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","categories":["water"],"row_index":133,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"地下水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.1.2, 6.2, 6.3 | PN-77/C-04584","methodology_zh":"化学和物理检测采样 所采水样的温度","test_object_zh":"地下水"},{"_id":"6a5dc9bef1c10c8ce825ea81","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Ścieki, Wody opadowe, Wody roztopowe","test_object_en":"Wastewater, Rainwater, Snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,5 – 50) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,5 – 50) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, Wody opadowe, Wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki, Wody opadowe, Wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,5 – 50) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":134,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, Rainwater, Snowmelt water Sampling for chemical and physical testing Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"废水、雨水、融雪水 化学与物理检测用样品采集 手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手工法","test_object_zh":"废水、雨水、融雪水"},{"_id":"6a5dc9bef1c10c8ce825ea82","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki wody"},{"name":"Zakres","range":"(0,5 – 50) °C"}],"parameters_en":[{"name":"Temperature of the collected water sample"},{"name":"Range","range":"(0,5 – 50) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (0,5 – 50) °C\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wył. pkt 7.6 | PN-EN ISO 5667-6:2016-12 /A11:2020-10 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wył. pkt 7.6","PN-EN ISO 5667-6:2016-12 /A11:2020-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki wody\nZakres (0,5 – 50) °C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wył. pkt 7.6 | PN-EN ISO 5667-6:2016-12 /A11:2020-10 | PN-77/C-04584 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki wody\nZakres (0,5 – 50) °C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wyl. pkt 7.6 | PN-EN ISO 5667-6:2016-12 /A11:2020-10 | PN-77/C-04584","categories":["water"],"row_index":135,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water Sampling for chemical and physical testing Manual method Temperature of the collected water sample Range PN-EN ISO 5667-6:2016-12 z wył. pkt 7.6 | PN-EN ISO 5667-6:2016-12 /A11:2020-10 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采水样的温度"},{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"地表水 化学与物理检测用样品采集 手工法 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wył. pkt 7.6 | PN-EN ISO 5667-6:2016-12 /A11:2020-10 | PN-77/C-04584","technique_zh":"手工法","test_object_zh":"地表水"},{"_id":"6a5dc9bef1c10c8ce825ea83","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12)"}],"parameters_en":[{"name":"Range","range":"(2,0 – 12)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (2,0 – 12)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres (2,0 – 12)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres (2,0 – 12)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":136,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12)"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea84","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 – 12900) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 – 12900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 12900) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (5 – 12900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (5 – 12900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":137,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 12900) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea85","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zasadowość ogólna Zasadowość złożona","methodology_en":"Total alkalinity Composite alkalinity","parameters":[{"name":"Zakres","range":"(0,40 – 20) mmol/l"},{"name":"Zakres","range":"(0,20 – 10) mmol/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,40 – 20) mmol/l"},{"name":"Range","range":"(0,20 – 10) mmol/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna Zasadowość złożona\nZakres:\nZakres (0,40 – 20) mmol/l\nZakres (0,20 – 10) mmol/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zasadowość ogólna Zasadowość złożona\nZakres:\nZakres (0,40 – 20) mmol/l\nZakres (0,20 – 10) mmol/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Scieki Zasadowosc ogolna Zasadowosc zlozona\nZakres:\nZakres (0,40 – 20) mmol/l\nZakres (0,20 – 10) mmol/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":138,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total alkalinity Composite alkalinity Titrimetric method Range Range PN-EN ISO 9963-1:2001+Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,40 – 20) mmol/l"},{"name":"范围","range":"(0,20 – 10) mmol/l CaCO3"}],"search_zh":"水、污水 滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea86","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie wodorowęglanów (HCO3-) (z obliczeń)","methodology_en":"Bicarbonate (HCO3-) concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wodorowęglanów (HCO3-) (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie wodorowęglanów (HCO3-) (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 Woda, Scieki Stezenie wodoroweglanow (HCO3-) (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":139,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Bicarbonate (HCO3-) concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004","search_zh":"水、污水 PN-EN ISO 9963-1:2001+Ap1:2004","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea87","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Kwasowość ogólna","methodology_en":"Total acidity","parameters":[{"name":"Zakres","range":"(0,05 – 5) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 5) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Kwasowość ogólna\nZakres (0,05 – 5) mmol/l\nMetoda miareczkowa","reference":"PN-90/C-04540/03+Az1:2003","norm_bases":["PN-90/C-04540/03+Az1:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Kwasowość ogólna\nZakres (0,05 – 5) mmol/l\nMetoda miareczkowa PN-90/C-04540/03+Az1:2003 Woda, Scieki Kwasowosc ogolna\nZakres (0,05 – 5) mmol/l\nMetoda miareczkowa PN-90/C-04540/03+Az1:2003","categories":["water"],"row_index":140,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total acidity Titrimetric method Range PN-90/C-04540/03+Az1:2003","parameters_zh":[{"name":"范围","range":"(0,05 – 5) mmol/l"}],"search_zh":"水、污水 总酸度 滴定法 范围 PN-90/C-04540/03+Az1:2003","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"总酸度"},{"_id":"6a5dc9bef1c10c8ce825ea88","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(0,05 – 10) mmol/l"},{"name":"Zakres","range":"(5 – 1000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(0,05 – 10) mmol/l"},{"name":"Range","range":"(5 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 10) mmol/l\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 10) mmol/l\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Scieki Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (0,05 – 10) mmol/l\nZakres (5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":141,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total content of calcium and magnesium (total hardness) Titrimetric method Range Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(0,05 – 10) mmol/l"},{"name":"范围","range":"(5 – 1000) mg/l CaCO3"}],"search_zh":"水、污水 钙与镁总量（总硬度） 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea89","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(0,05 – 10) mmol/l"},{"name":"Zakres","range":"(2 – 400) mg/l Ca"}],"parameters_en":[{"name":"Range","range":"(0,05 – 10) mmol/l"},{"name":"Range","range":"(2 – 400) mg/l Ca"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres:\nZakres (0,05 – 10) mmol/l\nZakres (2 – 400) mg/l Ca\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie wapnia\nZakres:\nZakres (0,05 – 10) mmol/l\nZakres (2 – 400) mg/l Ca\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Scieki Stezenie wapnia\nZakres:\nZakres (0,05 – 10) mmol/l\nZakres (2 – 400) mg/l Ca\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":142,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Calcium concentration Titrimetric method Range Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(0,05 – 10) mmol/l"},{"name":"范围","range":"(2 – 400) mg/l Ca"}],"search_zh":"水、污水 钙浓度 滴定法 范围 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"钙浓度"},{"_id":"6a5dc9bef1c10c8ce825ea8a","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(0,02 – 25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (0,02 – 25) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie żelaza\nZakres (0,02 – 25) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 Woda, Scieki Stezenie zelaza\nZakres (0,02 – 25) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":143,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 25) mg/l"}],"search_zh":"水、污水 铁浓度 分光光度法 范围 PN-ISO 6332:2001","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea8b","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,04 – 6,4) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 6,4) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,04 – 6,4) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,04 – 6,4) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 4 Woda, Scieki Stezenie ortofosforanow\nZakres (0,04 – 6,4) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 4","categories":["water"],"row_index":144,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 4","parameters_zh":[{"name":"范围","range":"(0,04 – 6,4) mg/l"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 4","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9bef1c10c8ce825ea8c","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,04 – 8,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 8,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,04 – 8,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,04 – 8,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,04 – 8,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7","categories":["water"],"row_index":145,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 8,0) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 + Ap2:2010 pkt 7","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea8d","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","methodology_en":"Chemical oxygen demand COD-Cr","parameters":[{"name":"Zakres","range":"(30 – 700) mg/l"}],"parameters_en":[{"name":"Range","range":"(30 – 700) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (30 – 700) mg/l\nMetoda miareczkowa","reference":"PN ISO 6060:2006","norm_bases":["PN ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (30 – 700) mg/l\nMetoda miareczkowa PN ISO 6060:2006 Woda, Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (30 – 700) mg/l\nMetoda miareczkowa PN ISO 6060:2006","categories":["water"],"row_index":146,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand COD-Cr Titrimetric method Range PN ISO 6060:2006","parameters_zh":[{"name":"范围","range":"(30 – 700) mg/l"}],"search_zh":"水、污水 化学需氧量 COD-Cr 滴定法 范围 PN ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a5dc9bef1c10c8ce825ea8e","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Substancje rozpuszczone","methodology_en":"Dissolved solids","parameters":[{"name":"Zakres","range":"(40 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(40 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje rozpuszczone\nZakres (40 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Substancje rozpuszczone\nZakres (40 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Substancje rozpuszczone\nZakres (40 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":147,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(40 – 2000) mg/l"}],"search_zh":"水、污水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性固体"},{"_id":"6a5dc9bef1c10c8ce825ea8f","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(40 – 2500) mg/l"}],"parameters_en":[{"name":"Range","range":"(40 – 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (40 – 2500) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Sucha pozostałość\nZakres (40 – 2500) mg/l\nMetoda wagowa PN-78/C-04541 Woda, Scieki Sucha pozostalosc\nZakres (40 – 2500) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":148,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Dry residue Gravimetric method Range PN-78/C-04541","parameters_zh":[{"name":"范围","range":"(40 – 2500) mg/l"}],"search_zh":"水、污水 干残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"干残渣"},{"_id":"6a5dc9bef1c10c8ce825ea90","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe, Wody roztopowe","test_object_en":"Water, Wastewater, Rainwater, Snowmelt water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, Wody opadowe, Wody roztopowe Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki, Wody opadowe, Wody roztopowe Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":149,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, Rainwater, Snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9bef1c10c8ce825ea91","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 − 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 − 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 − 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,0 − 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,0 − 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":150,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 − 1000) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea92","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10,0 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10,0 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10,0 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10,0 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10,0 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":151,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 1000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea93","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"zakres","range":"(0,10 - 10) mg/l"}],"parameters_en":[{"name":"range","range":"(0,10 - 10) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nzakres (0,10 - 10) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588.03","norm_bases":["PN-78/C-04588.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fluorków\nzakres (0,10 - 10) mg/l\nMetoda potencjometryczna PN-78/C-04588.03 Woda, Scieki Stezenie fluorkow\nzakres (0,10 - 10) mg/l\nMetoda potencjometryczna PN-78/C-04588.03","categories":["water"],"row_index":152,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Fluoride concentration Potentiometric method range PN-78/C-04588.03","search_zh":"水、污水 氟化物浓度 电位法 范围 PN-78/C-04588.03","technique_zh":"电位法","test_object_zh":"水、污水","methodology_zh":"氟化物浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 10) mg/l"}]},{"_id":"6a5dc9bef1c10c8ce825ea94","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,44 - 221) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,44 - 221) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 50) mg/l\nStężenie azotanów\nZakres (0,44 - 221) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,10 – 50) mg/l\nStężenie azotanów\nZakres (0,44 - 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,10 – 50) mg/l\nStezenie azotanow\nZakres (0,44 - 221) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":153,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range Nitrate concentration Range PN-82/C-04576.08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,44 - 221) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 硝酸盐浓度 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea95","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"zakres","range":"(0,006 – 3,0) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,02 – 10,0) mg/l"}],"parameters_en":[{"name":"range","range":"(0,006 – 3,0) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,02 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres:\nzakres (0,006 – 3,0) mg/l\nStężenie azotynów\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres:\nzakres (0,006 – 3,0) mg/l\nStężenie azotynów\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres:\nzakres (0,006 – 3,0) mg/l\nStezenie azotynow\nZakres (0,02 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":154,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method range Nitrite concentration Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,006 – 3,0) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,02 – 10,0) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea96","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 – 31,0) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,05 – 40,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 31,0) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,05 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,04 – 31,0) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,04 – 31,0) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 40,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres:\nZakres (0,04 – 31,0) mg/l\nStezenie jonu amonowego\nZakres (0,05 – 40,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":155,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 31,0) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,05 – 40,0) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 铵离子浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825ea97","lab_id":"69ad52a3de79e566650fb3ee","country":"PL","accr_number":"AB 782","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,1 – 1250) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 1250) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,1 – 1250) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012+Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012+Ap1:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres (0,1 – 1250) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07 Woda, Scieki Stezenie rteci\nZakres (0,1 – 1250) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07","categories":["water"],"row_index":156,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012+Ap1:2016-07","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 1250) μg/l"}],"search_zh":"水、污水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012+Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、污水"}],"has_pdf":true}