{"lab":{"_id":"69ad52a3de79e566650fb3e2","accr_number":"AB 772","country":"PL","accr_body":"PCA","address":"ul. Licealna 9, 65-417 Zielona Góra, CENTRALNE LABORATORIUM INSTYTUTU, INŻYNIERII ŚRODOWISKA","categories":["water","environment"],"city":"Zielona Góra","imported_at":"2026-03-08T10:42:43.265Z","methods_count":39,"name":"UNIWERSYTET ZIELONOGÓRSKI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_772.pdf"],"scope_summary":"","search_text":"uniwersytet zielonogórski ul. licealna 9, 65-417 zielona góra, centralne laboratorium instytutu, inżynierii środowiska water other pharma electronics environment materials metrology","status":"active","updated_at":"2026-03-08T14:51:39.581Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:39.581Z","location":{"type":"Point","coordinates":[15.5062,51.9356]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20772,podmiot.html","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia, ścieków, gleby, odpadów/","en":""},{"codes":"N/28/P, N/29/P, N/30/P, N/31/P, N/32/P","pl":"Chemical tests and sampling of water, drinking water, sewage, soil, waste","en":""}],"issue":{"no":"19","date":"19.01.2026"},"parse_date":"2026-07-20T07:09:50.137Z","parse_source":"script-pdfplumber","map_coord":[51.936465,15.507071],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":23,"environment":12,"other":4,"metrology":2,"materials":2},"category_scores":{"water":12.3,"environment":3.35,"other":0.37,"metrology":0.09,"materials":0.09},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825e8ac","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-5:2017-10","norm_bases":["PN-EN ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-EN ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-EN ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5dc9bef1c10c8ce825e8ad","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-11:2017-10 z wyłaczeniem pkt 5.2, 6.1.2, 6.2, 6.3","norm_bases":["PN-EN ISO 5667-11:2017-10 z wyłaczeniem pkt 5.2, 6.1.2, 6.2, 6.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-11:2017-10 z wyłaczeniem pkt 5.2, 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-11:2017-10 z wylaczeniem pkt 5.2, 6.1.2, 6.2, 6.3","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-11:2017-10 z wyłaczeniem pkt 5.2, 6.1.2, 6.2, 6.3","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-11:2017-10 z wyłaczeniem pkt 5.2, 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e8ae","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,02 – 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-6","norm_bases":["PN-ISO 6332:2001","PN-ISO 6332:2001/Ap1:2016-6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-6 Woda Stezenie zelaza ogolnego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-6","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-6","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 5,0) mg/l"}],"search_zh":"水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-6","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e8af","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu ogólnego","methodology_en":"Total manganese concentration","parameters":[{"name":"Zakres","range":"(0,05 – 4,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu ogólnego\nZakres (0,05 – 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu ogólnego\nZakres (0,05 – 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda Stezenie manganu ogolnego\nZakres (0,05 – 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total manganese concentration Spectrophotometric method Range PN-92/C-04590.03","parameters_zh":[{"name":"范围","range":"(0,05 – 4,0) mg/l"}],"search_zh":"水 总锰浓度 分光光度法 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"总锰浓度"},{"_id":"6a5dc9bef1c10c8ce825e8b0","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforanów","methodology_en":"Phosphate concentration","parameters":[{"name":"Zakres","range":"(0,04 – 0,40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 0,40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforanów\nZakres (0,04 – 0,40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/p1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4","PN-EN ISO 6878:2006/p1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforanów\nZakres (0,04 – 0,40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/p1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Woda Stezenie fosforanow\nZakres (0,04 – 0,40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/p1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/p1:2010 | PN-EN ISO 6878:2006/Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,04 – 0,40) mg/l"}],"search_zh":"水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 | PN-EN ISO 6878:2006/p1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"磷酸盐浓度"},{"_id":"6a5dc9bef1c10c8ce825e8b1","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fosforu","methodology_en":"Phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,04 – 0,40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 0,40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu\nZakres (0,04 – 0,40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fosforu\nZakres (0,04 – 0,40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Woda Stezenie fosforu\nZakres (0,04 – 0,40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,04 – 0,40) mg/l"}],"search_zh":"水 磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"磷浓度"},{"_id":"6a5dc9bef1c10c8ce825e8b2","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-EN ISO 5667-10:2021-11","norm_bases":["PN-EN ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-EN ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-EN ISO 5667-10:2021-11","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-EN ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-EN ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a5dc9bef1c10c8ce825e8b3","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e8b4","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(10 – 2000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(10 – 2000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 2000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (10 – 2000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 2000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 2000) μS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e8b5","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 150) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e8b6","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, Scieki Stezenie azotu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-C-04576-4:1994","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e8b7","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,01 – 0,25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,01 – 0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,01 – 0,25) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,01 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,01 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 0,25) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e8b8","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,1 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,1 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,1 – 1,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,1 – 1,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 1,0) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e8b9","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 600) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 600) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 600) mg/l\nMetoda miareczkowa","reference":"PB-09 edycja 3 z dnia 22.01.2024","norm_bases":["PB-09 edycja 3 z dnia 22.01.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10 – 600) mg/l\nMetoda miareczkowa PB-09 edycja 3 z dnia 22.01.2024 Woda, Scieki Stezenie siarczanow\nZakres (10 – 600) mg/l\nMetoda miareczkowa PB-09 edycja 3 z dnia 22.01.2024","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Titrimetric method Range PB-09 edycja 3 z dnia 22.01.2024","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 600) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 滴定法 范围 PB-09 edycja 3 z dnia 22.01.2024","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e8ba","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu","methodology_en":"Phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,04 – 10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu\nZakres (0,04 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu\nZakres (0,04 – 10) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Scieki Stezenie fosforu\nZakres (0,04 – 10) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,04 – 10) mg/l"}],"search_zh":"污水 磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"磷浓度"},{"_id":"6a5dc9bef1c10c8ce825e8bb","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","methodology_en":"Chemical oxygen demand - COD","parameters":[{"name":"Zakres","range":"(30 – 7000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(30 – 7000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand - COD Titrimetric method Range PN-ISO 6060:2006","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(30 – 7000) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e8bc","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(8 – 4000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(8 – 4000) mg/l O2"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"technique_en":"Manometric method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (8 – 4000) mg/l O2\nMetoda manometryczna","reference":"PB-08 edycja 2 z dnia: 18.10.2012","norm_bases":["PB-08 edycja 2 z dnia: 18.10.2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (8 – 4000) mg/l O2\nMetoda manometryczna PB-08 edycja 2 z dnia: 18.10.2012 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (8 – 4000) mg/l O2\nMetoda manometryczna PB-08 edycja 2 z dnia: 18.10.2012","categories":["water","metrology"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Manometric method Range PB-08 edycja 2 z dnia: 18.10.2012","parameters_zh":[{"name":"范围","range":"(8 – 4000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 压力计法 范围 PB-08 edycja 2 z dnia: 18.10.2012","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）","technique_zh":"压力计法"},{"_id":"6a5dc9bef1c10c8ce825e8bd","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bef1c10c8ce825e8be","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","norm_bases":["PN-EN 872:2007","PN-EN 872:2007/Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e8bf","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(5,0 – 60,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 60,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,0 – 60,0) mg/l\nMetoda miareczkowa","reference":"PB-03 edycja 3 z dnia 14.10.2015","norm_bases":["PB-03 edycja 3 z dnia 14.10.2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (5,0 – 60,0) mg/l\nMetoda miareczkowa PB-03 edycja 3 z dnia 14.10.2015 Scieki Stezenie azotu Kjeldahla\nZakres (5,0 – 60,0) mg/l\nMetoda miareczkowa PB-03 edycja 3 z dnia 14.10.2015","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PB-03 edycja 3 z dnia 14.10.2015","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 60,0) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PB-03 edycja 3 z dnia 14.10.2015","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e8c0","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-02 edycja 4 z dnia 30.01.2025","norm_bases":["PB-02 edycja 4 z dnia 30.01.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PB-02 edycja 4 z dnia 30.01.2025 Scieki Stezenie azotu ogolnego (z obliczen) PB-02 edycja 4 z dnia 30.01.2025","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration (calculated) PB-02 edycja 4 z dnia 30.01.2025","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PB-02 edycja 4 z dnia 30.01.2025","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e8c1","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 pkt. 7","norm_bases":["PN-ISO 10381-4:2007 pkt. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 pkt. 7 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 pkt. 7","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 pkt. 7","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007 pkt. 7","test_object_zh":"土壤"},{"_id":"6a5dc9bef1c10c8ce825e8c2","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH - w H2O","methodology_en":"pH - in H2O","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-ISO 10390:1997","norm_bases":["PN-ISO 10390:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH - w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-ISO 10390:1997 Gleba pH - w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-ISO 10390:1997","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH - in H2O Potentiometric method Range PN-ISO 10390:1997","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"土壤 pH - 于 H2O 中 电位法 范围 PN-ISO 10390:1997","technique_zh":"电位法","test_object_zh":"土壤","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a5dc9bef1c10c8ce825e8c3","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość metali:","methodology_en":"Metal content:","parameters":[{"name":"Kadm","range":"(2,00- 5,00) mg/kg"},{"name":"Miedź","range":"(1,00 – 50,0) mg/kg"},{"name":"Nikiel","range":"(1,00 – 20,0) mg/kg"},{"name":"Ołów","range":"(2,50 – 50,0) mg/kg"},{"name":"Cynk","range":"(10,0 – 200) mg/kg"},{"name":"Chrom","range":"(2,00 – 50,0) mg/kg"},{"name":"Rtęć","range":"(0,250 – 3,00) mg/kg"}],"parameters_en":[{"name":"Cadmium","range":"(2,00- 5,00) mg/kg"},{"name":"Copper","range":"(1,00 – 50,0) mg/kg"},{"name":"Nickel","range":"(1,00 – 20,0) mg/kg"},{"name":"Lead","range":"(2,50 – 50,0) mg/kg"},{"name":"Zinc","range":"(10,0 – 200) mg/kg"},{"name":"Chromium","range":"(2,00 – 50,0) mg/kg"},{"name":"Mercury","range":"(0,250 – 3,00) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość metali:\nZakres:\nKadm (2,00- 5,00) mg/kg\nMiedź (1,00 – 50,0) mg/kg\nNikiel (1,00 – 20,0) mg/kg\nOłów (2,50 – 50,0) mg/kg\nCynk (10,0 – 200) mg/kg\nChrom (2,00 – 50,0) mg/kg\nRtęć (0,250 – 3,00) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 11466:2002","norm_bases":["PN-EN ISO 11885:2009 z wył. pkt. 9","PN-EN ISO 11466:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość metali:\nZakres:\nKadm (2,00- 5,00) mg/kg\nMiedź (1,00 – 50,0) mg/kg\nNikiel (1,00 – 20,0) mg/kg\nOłów (2,50 – 50,0) mg/kg\nCynk (10,0 – 200) mg/kg\nChrom (2,00 – 50,0) mg/kg\nRtęć (0,250 – 3,00) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES) PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 11466:2002 Gleba Zawartosc metali:\nZakres:\nKadm (2,00- 5,00) mg/kg\nMiedz (1,00 – 50,0) mg/kg\nNikiel (1,00 – 20,0) mg/kg\nOlow (2,50 – 50,0) mg/kg\nCynk (10,0 – 200) mg/kg\nChrom (2,00 – 50,0) mg/kg\nRtec (0,250 – 3,00) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzezonej (ICP-OES) PN-EN ISO 11885:2009 z wyl. pkt. 9 | PN-EN ISO 11466:2002","categories":["materials","environment"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Metal content: Inductively coupled plasma optical emission spectrometry (ICP-OES) Cadmium Copper Nickel Lead Zinc Chromium Mercury PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 11466:2002","parameters_zh":[{"name":"镉","range":"(2,00- 5,00) mg/kg"},{"name":"铜","range":"(1,00 – 50,0) mg/kg"},{"name":"镍","range":"(1,00 – 20,0) mg/kg"},{"name":"铅","range":"(2,50 – 50,0) mg/kg"},{"name":"锌","range":"(10,0 – 200) mg/kg"},{"name":"铬","range":"(2,00 – 50,0) mg/kg"},{"name":"汞","range":"(0,250 – 3,00) mg/kg"}],"search_zh":"土壤 金属含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 镉 铜 镍 铅 锌 铬 汞 PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 11466:2002","test_object_zh":"土壤","methodology_zh":"金属含量：","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a5dc9bef1c10c8ce825e8c4","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99","test_object_en":"Waste code: 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99","methodology":"Skład morfologiczny","methodology_en":"Morphological composition","parameters":[],"parameters_en":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Skład morfologiczny\nMetoda wagowa","reference":"PN-Z-15006:1993","norm_bases":["PN-Z-15006:1993"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Skład morfologiczny\nMetoda wagowa PN-Z-15006:1993 Odpady kod: 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Sklad morfologiczny\nMetoda wagowa PN-Z-15006:1993","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Morphological composition Gravimetric method PN-Z-15006:1993","search_zh":"形态组成 重量法 PN-Z-15006:1993","technique_zh":"重量法","methodology_zh":"形态组成"},{"_id":"6a5dc9bef1c10c8ce825e8c5","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99","test_object_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99","methodology":"Aktywność oddechowa (AT4)","methodology_en":"Respiration activity (AT4)","parameters":[{"name":"Zakres","range":"(10 – 300) mg/g s.m."}],"parameters_en":[{"name":"Range","range":"(10 – 300) mg/g s.m."}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"technique_en":"Manometric method","computed":[],"computed_en":[],"activity":"Aktywność oddechowa (AT4)\nZakres (10 – 300) mg/g s.m.\nMetoda manometryczna","reference":"PB-06, edycja 2 z dnia 07.10.2014","norm_bases":["PB-06, edycja 2 z dnia 07.10.2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Aktywność oddechowa (AT4)\nZakres (10 – 300) mg/g s.m.\nMetoda manometryczna PB-06, edycja 2 z dnia 07.10.2014 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Aktywnosc oddechowa (AT4)\nZakres (10 – 300) mg/g s.m.\nMetoda manometryczna PB-06, edycja 2 z dnia 07.10.2014","categories":["environment","metrology"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 12 09, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Respiration activity (AT4) Manometric method Range PB-06, edycja 2 z dnia 07.10.2014","parameters_zh":[{"name":"范围","range":"(10 – 300) mg/g s.m."}],"search_zh":"呼吸活性（AT4） 压力计法 范围 PB-06, edycja 2 z dnia 07.10.2014","technique_zh":"压力计法","methodology_zh":"呼吸活性（AT4）"},{"_id":"6a5dc9bef1c10c8ce825e8c6","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","test_object_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012 | PB-05 edycja 01 z dnia 13.03.2012","norm_bases":["PN-EN ISO 10523:2012","PB-05 edycja 01 z dnia 13.03.2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 | PB-05 edycja 01 z dnia 13.03.2012 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 | PB-05 edycja 01 z dnia 13.03.2012","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 pH Potentiometric method Range PN-EN ISO 10523:2012 | PB-05 edycja 01 z dnia 13.03.2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10523:2012 | PB-05 edycja 01 z dnia 13.03.2012","technique_zh":"电位法"},{"_id":"6a5dc9bef1c10c8ce825e8c7","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","test_object_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","methodology":"Zawartość chlorków","methodology_en":"Chloride content","parameters":[{"name":"Zakres","range":"(50 – 1500) mg/kg"}],"parameters_en":[{"name":"Range","range":"(50 – 1500) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chlorków\nZakres (50 – 1500) mg/kg\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 | PB-05 edycja 01 z dnia 13.03.2012","norm_bases":["PN-ISO 9297:1994","PB-05 edycja 01 z dnia 13.03.2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Zawartość chlorków\nZakres (50 – 1500) mg/kg\nMetoda miareczkowa PN-ISO 9297:1994 | PB-05 edycja 01 z dnia 13.03.2012 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Zawartosc chlorkow\nZakres (50 – 1500) mg/kg\nMetoda miareczkowa PN-ISO 9297:1994 | PB-05 edycja 01 z dnia 13.03.2012","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Chloride content Titrimetric method Range PN-ISO 9297:1994 | PB-05 edycja 01 z dnia 13.03.2012","parameters_zh":[{"name":"范围","range":"(50 – 1500) mg/kg"}],"search_zh":"氯化物含量 滴定法 范围 PN-ISO 9297:1994 | PB-05 edycja 01 z dnia 13.03.2012","technique_zh":"滴定法","methodology_zh":"氯化物含量"},{"_id":"6a5dc9bef1c10c8ce825e8c8","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","test_object_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","methodology":"Zawartość siarczanów","methodology_en":"Sulfate content","parameters":[{"name":"Zakres","range":"(100 – 6000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(100 – 6000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość siarczanów\nZakres (100 – 6000) mg/kg\nMetoda miareczkowa","reference":"PB-09 edycja 3 z dnia 22.01.2024 | PB-05 edycja 01 z dnia 13.03.2012","norm_bases":["PB-09 edycja 3 z dnia 22.01.2024","PB-05 edycja 01 z dnia 13.03.2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Zawartość siarczanów\nZakres (100 – 6000) mg/kg\nMetoda miareczkowa PB-09 edycja 3 z dnia 22.01.2024 | PB-05 edycja 01 z dnia 13.03.2012 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Zawartosc siarczanow\nZakres (100 – 6000) mg/kg\nMetoda miareczkowa PB-09 edycja 3 z dnia 22.01.2024 | PB-05 edycja 01 z dnia 13.03.2012","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 06 06, 19 12 01, 19 12 09, 20 01 01, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Sulfate content Titrimetric method Range PB-09 edycja 3 z dnia 22.01.2024 | PB-05 edycja 01 z dnia 13.03.2012","parameters_zh":[{"name":"范围","range":"(100 – 6000) mg/kg"}],"search_zh":"硫酸盐含量 滴定法 范围 PB-09 edycja 3 z dnia 22.01.2024 | PB-05 edycja 01 z dnia 13.03.2012","technique_zh":"滴定法","methodology_zh":"硫酸盐含量"},{"_id":"6a5dc9bef1c10c8ce825e8c9","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","test_object_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PB-04, edycja 1 z dnia 18.09.2012","norm_bases":["PB-04, edycja 1 z dnia 18.09.2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Pobieranie próbek do badań chemicznych i fizycznych PB-04, edycja 1 z dnia 18.09.2012 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Pobieranie probek do badan chemicznych i fizycznych PB-04, edycja 1 z dnia 18.09.2012","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 03, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Sampling for chemical and physical testing PB-04, edycja 1 z dnia 18.09.2012","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PB-04, edycja 1 z dnia 18.09.2012"},{"_id":"6a5dc9bef1c10c8ce825e8ca","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","test_object_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","methodology":"Zawartość wody","methodology_en":"Water content","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-Z-15008-02:1993","norm_bases":["PN-Z-15008-02:1993"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Zawartość wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-Z-15008-02:1993 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Zawartosc wody\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-Z-15008-02:1993","categories":["environment","water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Water content Gravimetric method Range PN-Z-15008-02:1993","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"水分含量 重量法 范围 PN-Z-15008-02:1993","technique_zh":"重量法"},{"_id":"6a5dc9bef1c10c8ce825e8cb","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","test_object_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady kod: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 05, 19 12 01, 19 12 09, 20 01 08, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 06, 20 03 99 Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a5dc9bef1c10c8ce825e8cc","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Odpady kod: 190805, Pobieranie próbek do badań chemicznych i fizycznych","test_object_en":"Waste code: 190805, Sampling for chemical and physical testing","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN ISO 5667-13:2011 pkt 6.3.6","norm_bases":["PN-EN ISO 5667-13:2011 pkt 6.3.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 190805, Pobieranie próbek do badań chemicznych i fizycznych Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN ISO 5667-13:2011 pkt 6.3.6 Odpady kod: 190805, Pobieranie probek do badan chemicznych i fizycznych Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN ISO 5667-13:2011 pkt 6.3.6","categories":["environment"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 190805, Sampling for chemical and physical testing Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN ISO 5667-13:2011 pkt 6.3.6","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN ISO 5667-13:2011 pkt 6.3.6","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a5dc9bef1c10c8ce825e8cd","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"pH - w H2O, Zakres: 4,0 - 10,0, Metoda potencjometryczna","test_object_en":"pH - in H2O, Range: 4,0 - 10,0, Potentiometric method","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"pH - w H2O, Zakres: 4,0 - 10,0, Metoda potencjometryczna Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN ISO 10390:2022-09 pH - w H2O, Zakres: 4,0 - 10,0, Metoda potencjometryczna Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN ISO 10390:2022-09","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"pH - in H2O, Range: 4,0 - 10,0, Potentiometric method Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN ISO 10390:2022-09","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a5dc9bef1c10c8ce825e8ce","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Sucha pozostałość / zawartość wody, Zakres: (0,5 – 99,5) %, Metoda wagowa","test_object_en":"Dry residue / water content, Range: (0,5 – 99,5) %, Gravimetric method","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Sucha pozostałość / zawartość wody, Zakres: (0,5 – 99,5) %, Metoda wagowa Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 12880:2004 Sucha pozostalosc / zawartosc wody, Zakres: (0,5 – 99,5) %, Metoda wagowa Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Dry residue / water content, Range: (0,5 – 99,5) %, Gravimetric method Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a5dc9bef1c10c8ce825e8cf","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Straty przy prażeniu suchej masy (LOI), Zakres: (0,5 – 99,5) %, Metoda wagowa","test_object_en":"Loss on ignition of dry matter (LOI), Range: (0,5 – 99,5) %, Gravimetric method","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Straty przy prażeniu suchej masy (LOI), Zakres: (0,5 – 99,5) %, Metoda wagowa Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 12879:2004 Straty przy prazeniu suchej masy (LOI), Zakres: (0,5 – 99,5) %, Metoda wagowa Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 12879:2004","categories":["other"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Loss on ignition of dry matter (LOI), Range: (0,5 – 99,5) %, Gravimetric method Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 12879:2004","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 12879:2004","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a5dc9bef1c10c8ce825e8d0","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Zawartość azotu Kjeldahla, Zakres: (2,0 – 40,0) g/kg, Metoda miareczkowa","test_object_en":"Kjeldahl nitrogen content, Range: (2,0 – 40,0) g/kg, Titrimetric method","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PB-03 edycja 3 z dnia 14.10.2015","norm_bases":["PB-03 edycja 3 z dnia 14.10.2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zawartość azotu Kjeldahla, Zakres: (2,0 – 40,0) g/kg, Metoda miareczkowa Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PB-03 edycja 3 z dnia 14.10.2015 Zawartosc azotu Kjeldahla, Zakres: (2,0 – 40,0) g/kg, Metoda miareczkowa Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PB-03 edycja 3 z dnia 14.10.2015","categories":["other"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Kjeldahl nitrogen content, Range: (2,0 – 40,0) g/kg, Titrimetric method Loss on ignition of dry matter (LOI) Gravimetric method Range PB-03 edycja 3 z dnia 14.10.2015","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PB-03 edycja 3 z dnia 14.10.2015","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a5dc9bef1c10c8ce825e8d1","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Zawartość fosforu ogólnego, Zakres: (2,0 – 50,0) g/kg, Metoda spektrofotometryczna","test_object_en":"Total phosphorus content, Range: (2,0 – 50,0) g/kg, Spectrophotometric method","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006 pkt 8","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zawartość fosforu ogólnego, Zakres: (2,0 – 50,0) g/kg, Metoda spektrofotometryczna Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Zawartosc fosforu ogolnego, Zakres: (2,0 – 50,0) g/kg, Metoda spektrofotometryczna Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["other"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Total phosphorus content, Range: (2,0 – 50,0) g/kg, Spectrophotometric method Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a5dc9bef1c10c8ce825e8d2","lab_id":"69ad52a3de79e566650fb3e2","country":"PL","accr_number":"AB 772","accr_body":"PCA","test_object":"Zawartość metali: Zakres: Kadm (3,00- 5,00) mg/kg, Miedź (6,00 – 500) mg/kg, Nikiel (3,00 – 50,0) mg/kg, Ołów (7,00 – 400) mg/kg, Cynk (20,0 – 2000) mg/kg, Chrom (6,00 – 300) mg/kg, Rtęć (2,00 – 25,0) mg/kg, Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES)","test_object_en":"Metal content: Range: Cadmium (3,00- 5,00) mg/kg, Copper (6,00 – 500) mg/kg, Nickel (3,00 – 50,0) mg/kg, Lead (7,00 – 400) mg/kg, Zinc (20,0 – 2000) mg/kg, Chromium (6,00 – 300) mg/kg, Mercury (2,00 – 25,0) mg/kg, Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology":"Straty przy prażeniu suchej masy (LOI)","methodology_en":"Loss on ignition of dry matter (LOI)","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 13346:2002","norm_bases":["PN-EN ISO 11885:2009 z wył. pkt. 9","PN-EN ISO 13346:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zawartość metali: Zakres: Kadm (3,00- 5,00) mg/kg, Miedź (6,00 – 500) mg/kg, Nikiel (3,00 – 50,0) mg/kg, Ołów (7,00 – 400) mg/kg, Cynk (20,0 – 2000) mg/kg, Chrom (6,00 – 300) mg/kg, Rtęć (2,00 – 25,0) mg/kg, Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzężonej (ICP-OES) Straty przy prażeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 13346:2002 Zawartosc metali: Zakres: Kadm (3,00- 5,00) mg/kg, Miedz (6,00 – 500) mg/kg, Nikiel (3,00 – 50,0) mg/kg, Olow (7,00 – 400) mg/kg, Cynk (20,0 – 2000) mg/kg, Chrom (6,00 – 300) mg/kg, Rtec (2,00 – 25,0) mg/kg, Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnej sprzezonej (ICP-OES) Straty przy prazeniu suchej masy (LOI)\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN ISO 11885:2009 z wyl. pkt. 9 | PN-EN ISO 13346:2002","categories":["materials"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Metal content: Range: Cadmium (3,00- 5,00) mg/kg, Copper (6,00 – 500) mg/kg, Nickel (3,00 – 50,0) mg/kg, Lead (7,00 – 400) mg/kg, Zinc (20,0 – 2000) mg/kg, Chromium (6,00 – 300) mg/kg, Mercury (2,00 – 25,0) mg/kg, Inductively coupled plasma optical emission spectrometry (ICP-OES) Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 13346:2002","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN ISO 11885:2009 z wył. pkt. 9 | PN-EN ISO 13346:2002","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）"}],"has_pdf":true}