{"lab":{"_id":"69ad52a3de79e566650fb3dc","accr_number":"AB 769","country":"PL","accr_body":"PCA","address":"ul. Teatralna 49, 66-400 Gorzów Wielkopolski, LABORATORIUM, Stanowice 29","categories":["environment","water","petro","materials","construction","food"],"city":"Gorzów Wielkopolski","imported_at":"2026-03-08T10:42:43.265Z","methods_count":52,"name":"INNEKO SP. Z O.O.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_769.pdf"],"scope_summary":"","search_text":"inneko sp. z o.o. ul. teatralna 49, 66-400 gorzów wielkopolski, laboratorium, stanowice 29 water pharma electronics other environment petro construction food","status":"active","updated_at":"2026-03-08T14:51:39.383Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-27T00:40:18.346Z","location":{"type":"Point","coordinates":[15.2369,52.7325]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20769,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, osadów, odpadów","en":"Chemical tests and sampling of water, sewage, sediments, waste"},{"codes":"C/10","pl":"Badania chemiczne paliw stałych","en":"Chemical tests of solid fuels"},{"codes":"N/28/P; N/30/P; N/32/P","pl":"Badanie właściwości fizycznych i pobieranie próbek wody, ścieków, osadów, odpadów","en":"Tests of physical properties and sampling of water, sewage, sediments, waste"},{"codes":"N/10","pl":"Badanie właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"}],"issue":{"no":"23","date":"25.08.2026"},"parse_date":"2026-08-27T00:40:18.346Z","parse_source":"agent-claude-code","map_coord":[52.732137,15.245519],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":36,"water":25,"materials":10,"construction":10,"petro":9,"food":8,"metrology":1},"category_scores":{"environment":13.09,"water":6.31,"materials":1.01,"construction":1.01,"petro":0.82,"food":0.65,"metrology":0.01},"has_zh":true,"lab_locations":[{"name":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","address":"Stanowice 29","city":"Bogdaniec","postal":"66-450"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/26/7019737a62dbe37aa8d2b0dad5f2d6bf/AB%20769.pdf"},"methods":[{"_id":"6a8f8772289e4f5e07039dc8","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,100 – 36) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,100 – 36) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (0,100 – 36) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (0,100 – 36) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,100 – 36) mS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a8f8772289e4f5e07039dc9","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 9,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 9,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a8f8772289e4f5e07039dca","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO)","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO)\nZakres (5,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO)\nZakres (5,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO) i rozpuszczonego wegla organicznego (RWO)\nZakres (5,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、污水 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、污水"},{"_id":"6a8f8772289e4f5e07039dcb","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"Cd","range":"(0,40 – 4,0) μg/l"},{"name":"Cr","range":"(2,0 – 20) μg/l"},{"name":"Cu","range":"(3,0 – 30) μg/l"},{"name":"Pb","range":"(10,0 – 100) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nCd (0,40 – 4,0) μg/l\nCr (2,0 – 20) μg/l\nCu (3,0 – 30) μg/l\nPb (10,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nCd (0,40 – 4,0) μg/l\nCr (2,0 – 20) μg/l\nCu (3,0 – 30) μg/l\nPb (10,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Scieki Stezenie pierwiastkow\nZakres:\nCd (0,40 – 4,0) μg/l\nCr (2,0 – 20) μg/l\nCu (3,0 – 30) μg/l\nPb (10,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"元素浓度","parameters_zh":[{"name":"Cd","range":"(0,40 – 4,0) μg/l"},{"name":"Cr","range":"(2,0 – 20) μg/l"},{"name":"Cu","range":"(3,0 – 30) μg/l"},{"name":"Pb","range":"(10,0 – 100) μg/l"}],"search_zh":"水、污水 元素浓度 电热原子化原子吸收光谱法（ETAAS） Cd Cr Cu Pb PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、污水"},{"_id":"6a8f8772289e4f5e07039dcc","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00050 – 0,020) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,00050 – 0,020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres (0,00050 – 0,020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 Woda, Scieki Stezenie rteci\nZakres (0,00050 – 0,020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00050 – 0,020) mg/l"}],"search_zh":"水、污水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、污水"},{"_id":"6a8f8772289e4f5e07039dcd","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie cynku","parameters":[{"name":"Zakres","range":"(0,050 – 2,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie cynku\nZakres (0,050 – 2,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie cynku\nZakres (0,050 – 2,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Woda, Scieki Stezenie cynku\nZakres (0,050 – 2,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"锌浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 2,0) mg/l"}],"search_zh":"水、污水 锌浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水"},{"_id":"6a8f8772289e4f5e07039dce","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie rozpuszczonych anionów","parameters":[{"name":"chlorki","range":"(1,0 – 1000) mg/l"},{"name":"fluorki","range":"(0,10 – 20) mg/l"},{"name":"siarczany","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie rozpuszczonych anionów\nZakres:\nchlorki (1,0 – 1000) mg/l\nfluorki (0,10 – 20) mg/l\nsiarczany (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie rozpuszczonych anionów\nZakres:\nchlorki (1,0 – 1000) mg/l\nfluorki (0,10 – 20) mg/l\nsiarczany (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie rozpuszczonych anionow\nZakres:\nchlorki (1,0 – 1000) mg/l\nfluorki (0,10 – 20) mg/l\nsiarczany (1,0 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"氯化物","range":"(1,0 – 1000) mg/l"},{"name":"氟化物","range":"(0,10 – 20) mg/l"},{"name":"硫酸盐","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、污水 离子色谱-电导检测法（IC-CD） 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a8f8772289e4f5e07039dcf","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","technique_zh":"手工与自动法","test_object_zh":"污水"},{"_id":"6a8f8772289e4f5e07039dd0","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 50) °C","reference":"ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r.","norm_bases":["ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r."],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (5,0 – 50) °C ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r. Scieki Temperatura\nZakres (5,0 – 50) °C ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r.","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"温度","parameters_zh":[{"name":"范围","range":"(5,0 – 50) °C"}],"search_zh":"污水 温度 范围 ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r.","test_object_zh":"污水"},{"_id":"6a8f8772289e4f5e07039dd1","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie niklu","parameters":[{"name":"Zakres","range":"(0,0070 – 0,600) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie niklu\nZakres (0,0070 – 0,600) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie niklu\nZakres (0,0070 – 0,600) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki Stezenie niklu\nZakres (0,0070 – 0,600) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"镍浓度","parameters_zh":[{"name":"范围","range":"(0,0070 – 0,600) mg/l"}],"search_zh":"污水 镍浓度 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污水"},{"_id":"6a8f8772289e4f5e07039dd2","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 8.2, 9.2, 9.3, 9.4 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt 6.2.3, 13, 14","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3","PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 8.2, 9.2, 9.3, 9.4","PN-ISO 5667-4:2017-10 z wyłączeniem pkt 6.2.3, 13, 14"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 8.2, 9.2, 9.3, 9.4 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt 6.2.3, 13, 14 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wylaczeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wylaczeniem pkt 7.5, 8.2, 9.2, 9.3, 9.4 | PN-ISO 5667-4:2017-10 z wylaczeniem pkt 6.2.3, 13, 14","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2, 6.1.2, 6.2, 6.3 | PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 8.2, 9.2, 9.3, 9.4 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt 6.2.3, 13, 14","test_object_zh":"水"},{"_id":"6a8f8772289e4f5e07039dd3","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 50) °C","reference":"ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r.","norm_bases":["ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r."],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (5,0 – 50) °C ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r. Woda Temperatura\nZakres (5,0 – 50) °C ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"温度","parameters_zh":[{"name":"范围","range":"(5,0 – 50) °C"}],"search_zh":"水 温度 范围 ZUO/LAB/PB-42 wydanie 3 z dnia 07.02.2023 r.","test_object_zh":"水"},{"_id":"6a8f8772289e4f5e07039dd4","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 04 01 09, 05 06 99, 06 04 99, 07 02 13, 07 05 99, 08 01 14, 08 01 18, 10 01 19, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 13, 12 01 21, 12 01 99, 15 01 04, 15 01 06, 15 02 02, 16 01 21, 16 01 99, 16 03 04, 16 08 01, 17 03 02, 17 03 80, 19 01 10, 19 08 01, 19 08 02, 19 08 14, 20 01 08, 20 01 40, 20 01 99, 20 02 01, 20 02 03 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(1,00 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (1,00 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 04 01 09, 05 06 99, 06 04 99, 07 02 13, 07 05 99, 08 01 14, 08 01 18, 10 01 19, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 13, 12 01 21, 12 01 99, 15 01 04, 15 01 06, 15 02 02, 16 01 21, 16 01 99, 16 03 04, 16 08 01, 17 03 02, 17 03 80, 19 01 10, 19 08 01, 19 08 02, 19 08 14, 20 01 08, 20 01 40, 20 01 99, 20 02 01, 20 02 03 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Straty przy prażeniu suchej masy (LOI)\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe, Odpady O) kod: 04 01 09, 05 06 99, 06 04 99, 07 02 13, 07 05 99, 08 01 14, 08 01 18, 10 01 19, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 13, 12 01 21, 12 01 99, 15 01 04, 15 01 06, 15 02 02, 16 01 21, 16 01 99, 16 03 04, 16 08 01, 17 03 02, 17 03 80, 19 01 10, 19 08 01, 19 08 02, 19 08 14, 20 01 08, 20 01 40, 20 01 99, 20 02 01, 20 02 03 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Straty przy prazeniu suchej masy (LOI)\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment","water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"干物质烧失量（LOI）","parameters_zh":[{"name":"范围","range":"(1,00 – 90,0) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039dd5","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Osady ściekowe, Odpady O) kod: 04 01 09, 05 06 99, 06 04 99, 07 02 13, 07 05 99, 08 01 14, 08 01 18, 10 01 19, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 13, 12 01 21, 12 01 99, 15 01 04, 15 01 06, 15 02 02, 16 01 21, 16 01 99, 16 03 04, 16 08 01, 17 03 02, 17 03 80, 19 01 10, 19 08 01, 19 08 02, 19 08 14, 20 01 08, 20 01 40, 20 01 99, 20 02 01, 20 02 03 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Sucha pozostałość/zawartość wody","parameters":[{"name":"Zakres","range":"(1,00 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość/zawartość wody\nZakres (1,00 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Odpady O) kod: 04 01 09, 05 06 99, 06 04 99, 07 02 13, 07 05 99, 08 01 14, 08 01 18, 10 01 19, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 13, 12 01 21, 12 01 99, 15 01 04, 15 01 06, 15 02 02, 16 01 21, 16 01 99, 16 03 04, 16 08 01, 17 03 02, 17 03 80, 19 01 10, 19 08 01, 19 08 02, 19 08 14, 20 01 08, 20 01 40, 20 01 99, 20 02 01, 20 02 03 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Sucha pozostałość/zawartość wody\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Osady sciekowe, Odpady O) kod: 04 01 09, 05 06 99, 06 04 99, 07 02 13, 07 05 99, 08 01 14, 08 01 18, 10 01 19, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 13, 12 01 21, 12 01 99, 15 01 04, 15 01 06, 15 02 02, 16 01 21, 16 01 99, 16 03 04, 16 08 01, 17 03 02, 17 03 80, 19 01 10, 19 08 01, 19 08 02, 19 08 14, 20 01 08, 20 01 40, 20 01 99, 20 02 01, 20 02 03 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Sucha pozostalosc/zawartosc wody\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water","environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,00 – 90,0) %"}],"search_zh":"重量法 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039dd6","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"用于化学、物理检验的采样","search_zh":"污泥 用于化学、物理检验的采样 PN-EN ISO 5667-13:2011","test_object_zh":"污泥"},{"_id":"6a8f8772289e4f5e07039dd7","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a8f8772289e4f5e07039dd8","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 03 99, 02 07 99, 03 01 99, 03 03 99, 04 01 99, 07 02 03, 10 01 19, 10 03 20, 10 09 99, 10 10 02, 10 11 03, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 17, 12 01 21, 12 01 99, 16 01 03, 16 01 12, 16 01 21, 16 01 22, 16 01 99, 16 02 16, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 16 82 02, 17 01 82, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 01 99, 19 02 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organiczny (RWO)","parameters":[{"name":"Zakres","range":"(50,0 – 10000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organiczny (RWO)\nZakres (50,0 – 10000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999 | PN-EN 12457-4:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 03 99, 02 07 99, 03 01 99, 03 03 99, 04 01 99, 07 02 03, 10 01 19, 10 03 20, 10 09 99, 10 10 02, 10 11 03, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 17, 12 01 21, 12 01 99, 16 01 03, 16 01 12, 16 01 21, 16 01 22, 16 01 99, 16 02 16, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 16 82 02, 17 01 82, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 01 99, 19 02 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organiczny (RWO)\nZakres (50,0 – 10000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 | PN-EN 12457-4:2006 Odpady O) kod: 02 03 99, 02 07 99, 03 01 99, 03 03 99, 04 01 99, 07 02 03, 10 01 19, 10 03 20, 10 09 99, 10 10 02, 10 11 03, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 17, 12 01 21, 12 01 99, 16 01 03, 16 01 12, 16 01 21, 16 01 22, 16 01 99, 16 02 16, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 16 82 02, 17 01 82, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 01 99, 19 02 99, 19 08 01, 19 08 02, 19 08 14, 19 12 09, 20 03 06, 20 03 07, 20 03 99 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc ogolnego wegla organicznego (OWO) i rozpuszczonego wegla organiczny (RWO)\nZakres (50,0 – 10000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 | PN-EN 12457-4:2006","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(50,0 – 10000) mg/kg"}],"search_zh":"高温燃烧红外检测法 范围 PN-EN 1484:1999 | PN-EN 12457-4:2006","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8f8772289e4f5e07039dd9","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość cynku","parameters":[{"name":"Zakres","range":"(0,50 – 200) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość cynku\nZakres (0,50 – 200) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 | PN-EN 12457-4:2006","norm_bases":["PN-ISO 8288:2002","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość cynku\nZakres (0,50 – 200) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 | PN-EN 12457-4:2006 Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc cynku\nZakres (0,50 – 200) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 | PN-EN 12457-4:2006","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"锌含量","parameters_zh":[{"name":"范围","range":"(0,50 – 200) mg/kg"}],"search_zh":"锌含量 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 | PN-EN 12457-4:2006","technique_zh":"火焰原子吸收光谱法（FAAS）"},{"_id":"6a8f8772289e4f5e07039dda","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0050 – 2,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0050 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość rtęci\nZakres (0,0050 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006 Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc rteci\nZakres (0,0050 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0050 – 2,0) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a8f8772289e4f5e07039ddb","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość pierwiastków","parameters":[{"name":"Cd","range":"(0,0040 –5,0) mg/kg"},{"name":"Cr","range":"(0,020 –70,0) mg/kg"},{"name":"Cu","range":"(0,030 – 100) mg/kg"},{"name":"Pb","range":"(0,10 – 50,0) mg/kg"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCd (0,0040 –5,0) mg/kg\nCr (0,020 –70,0) mg/kg\nCu (0,030 – 100) mg/kg\nPb (0,10 – 50,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 15586:2005","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość pierwiastków\nZakres:\nCd (0,0040 –5,0) mg/kg\nCr (0,020 –70,0) mg/kg\nCu (0,030 – 100) mg/kg\nPb (0,10 – 50,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006 Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc pierwiastkow\nZakres:\nCd (0,0040 –5,0) mg/kg\nCr (0,020 –70,0) mg/kg\nCu (0,030 – 100) mg/kg\nPb (0,10 – 50,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"元素含量","parameters_zh":[{"name":"Cd","range":"(0,0040 –5,0) mg/kg"},{"name":"Cr","range":"(0,020 –70,0) mg/kg"},{"name":"Cu","range":"(0,030 – 100) mg/kg"},{"name":"Pb","range":"(0,10 – 50,0) mg/kg"}],"search_zh":"元素含量 电热原子化原子吸收光谱法（ETAAS） Cd Cr Cu Pb PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","technique_zh":"电热原子化原子吸收光谱法（ETAAS）"},{"_id":"6a8f8772289e4f5e07039ddc","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość baru","parameters":[{"name":"Zakres","range":"(10,0 – 300) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość baru\nZakres (10,0 – 300) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006","norm_bases":["ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r.","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość baru\nZakres (10,0 – 300) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006 Odpady O) kod: 02 01 04, 02 07 99, 03 01 05, 03 01 99, 03 03 99, 03 01 99, 04 02 22, 07 02 13, 07 02 99, 08 01 18, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 15, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 05 03, 17 03 80 19 01 10, 19 01 12, 19 08 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc baru\nZakres (10,0 – 300) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10,0 – 300) mg/kg"}],"search_zh":"火焰原子吸收光谱法（FAAS） 范围 ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006","technique_zh":"火焰原子吸收光谱法（FAAS）"},{"_id":"6a8f8772289e4f5e07039ddd","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 07 99, 03 01 99, 03 03 99, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 08 01, O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość pierwiastków","parameters":[{"name":"As","range":"(0,10 – 25,0) mg/kg"},{"name":"Sb","range":"(0,10 – 5,0) mg/kg"},{"name":"Se","range":"(0,10 – 7,0) mg/kg"},{"name":"Mo","range":"(0,06 – 30,0) mg/kg"},{"name":"Ni","range":"(0,07 – 40,0) mg/kg"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nAs (0,10 – 25,0) mg/kg\nSb (0,10 – 5,0) mg/kg\nSe (0,10 – 7,0) mg/kg\nMo (0,06 – 30,0) mg/kg\nNi (0,07 – 40,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 15586:2005","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 07 99, 03 01 99, 03 03 99, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 08 01, O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość pierwiastków\nZakres:\nAs (0,10 – 25,0) mg/kg\nSb (0,10 – 5,0) mg/kg\nSe (0,10 – 7,0) mg/kg\nMo (0,06 – 30,0) mg/kg\nNi (0,07 – 40,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006 Odpady O) kod: 02 07 99, 03 01 99, 03 03 99, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 08 01, O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc pierwiastkow\nZakres:\nAs (0,10 – 25,0) mg/kg\nSb (0,10 – 5,0) mg/kg\nSe (0,10 – 7,0) mg/kg\nMo (0,06 – 30,0) mg/kg\nNi (0,07 – 40,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"元素含量","parameters_zh":[{"name":"As","range":"(0,10 – 25,0) mg/kg"},{"name":"Sb","range":"(0,10 – 5,0) mg/kg"},{"name":"Se","range":"(0,10 – 7,0) mg/kg"},{"name":"Mo","range":"(0,06 – 30,0) mg/kg"},{"name":"Ni","range":"(0,07 – 40,0) mg/kg"}],"search_zh":"元素含量 电热原子化原子吸收光谱法（ETAAS） As Sb Se Mo Ni PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","technique_zh":"电热原子化原子吸收光谱法（ETAAS）"},{"_id":"6a8f8772289e4f5e07039dde","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 99, 03 03 99, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 09, 12 01 12, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 03 80, 17 05 03, 19 01 10 19 08 01, 19 08 02, 19 12 12 20 02 03, 20 03 06 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość anionów","parameters":[{"name":"chlorki","range":"(10 – 10000) mg/kg"},{"name":"fluorki","range":"(1,0 – 200) mg/kg"},{"name":"siarczany","range":"(10 – 10000) mg/kg"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość anionów\nZakres:\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 200) mg/kg\nsiarczany (10 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 01 04, 02 07 99, 03 01 99, 03 03 99, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 09, 12 01 12, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 03 80, 17 05 03, 19 01 10 19 08 01, 19 08 02, 19 12 12 20 02 03, 20 03 06 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość anionów\nZakres:\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 200) mg/kg\nsiarczany (10 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012 Odpady O) kod: 02 01 04, 02 07 99, 03 01 99, 03 03 99, 10 01 19, 10 03 20, 10 11 99, 10 12 99, 10 13 99, 12 01 09, 12 01 12, 12 01 21, 12 01 99, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 17 03 02, 17 03 80, 17 05 03, 19 01 10 19 08 01, 19 08 02, 19 12 12 20 02 03, 20 03 06 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc anionow\nZakres:\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 200) mg/kg\nsiarczany (10 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"阴离子含量","parameters_zh":[{"name":"氯化物","range":"(10 – 10000) mg/kg"},{"name":"氟化物","range":"(1,0 – 200) mg/kg"},{"name":"硫酸盐","range":"(10 – 10000) mg/kg"}],"search_zh":"阴离子含量 离子色谱-电导检测法（IC-CD） 氯化物 氟化物 硫酸盐 PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a8f8772289e4f5e07039ddf","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 07 99, 03 01 99, 03 03 99, 04 01 99, 07 02 03, 10 01 19, 10 03 20, 10 10 02, 10 11 03, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 17, 12 01 21, 12 01 99, 16 01 03, 16 01 12, 16 01 21, 16 01 22, 16 01 99, 16 02 16, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 16 82 02, 17 01 82, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 01 99, 19 02 99, 19 04 02, 19 08 01, 19 08 02, 19 08 14, 19 12 04, 19 12 09, 20 01 99, 20 02 03, 20 03 06 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość całkowitych substancji rozpuszczonych (TDS)","parameters":[{"name":"Zakres","range":"(2000 – 152 400) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość całkowitych substancji rozpuszczonych (TDS)\nZakres (2000 – 152 400) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-4:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 07 99, 03 01 99, 03 03 99, 04 01 99, 07 02 03, 10 01 19, 10 03 20, 10 10 02, 10 11 03, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 17, 12 01 21, 12 01 99, 16 01 03, 16 01 12, 16 01 21, 16 01 22, 16 01 99, 16 02 16, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 16 82 02, 17 01 82, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 01 99, 19 02 99, 19 04 02, 19 08 01, 19 08 02, 19 08 14, 19 12 04, 19 12 09, 20 01 99, 20 02 03, 20 03 06 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość całkowitych substancji rozpuszczonych (TDS)\nZakres (2000 – 152 400) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-4:2006 Odpady O) kod: 02 07 99, 03 01 99, 03 03 99, 04 01 99, 07 02 03, 10 01 19, 10 03 20, 10 10 02, 10 11 03, 10 11 99, 10 12 99, 10 13 99, 12 01 01, 12 01 02, 12 01 03, 12 01 04, 12 01 09, 12 01 12, 12 01 13, 12 01 17, 12 01 21, 12 01 99, 16 01 03, 16 01 12, 16 01 21, 16 01 22, 16 01 99, 16 02 16, 16 03 03, 16 03 04, 16 07 99, 16 08 01, 16 80 01, 16 81 01, 16 81 02, 16 82 02, 17 01 82, 17 03 02, 17 03 80, 17 05 03, 19 01 10, 19 01 99, 19 02 99, 19 04 02, 19 08 01, 19 08 02, 19 08 14, 19 12 04, 19 12 09, 20 01 99, 20 02 03, 20 03 06 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc calkowitych substancji rozpuszczonych (TDS)\nZakres (2000 – 152 400) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-4:2006","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2000 – 152 400) mg/kg"}],"search_zh":"重量法 范围 PN-EN 15216:2022-03 | PN-EN 12457-4:2006","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039de0","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 02 01 04, 02 07 05, 04 02 21, 04 02 22, 07 02 14, 12 01 05, 15 01 06, 15 02 02, 16 01 03 16 01 19, 16 01 21, 16 01 22, 16 01 99, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 04, 19 12 09, 19 12 10, 19 12 12, 20 01 10, 20 01 11, 20 01 28, 20 01 39, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99, Osady ściekowe, Paliwa stałe: stałe paliwo wtórne (SRF) O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość ogólnego węgla organicznego (TOC)","parameters":[{"name":"Zakres","range":"(7 – 500) g/kg"},{"name":"Zakres","range":"(7 000 – 500 000) mg/kg"},{"name":"Zakres","range":"(0,7 – 50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (7 – 500) g/kg\nZakres (7 000 – 500 000) mg/kg\nZakres (0,7 – 50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 13137:2004","norm_bases":["PN-EN 13137:2004"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 02 01 04, 02 07 05, 04 02 21, 04 02 22, 07 02 14, 12 01 05, 15 01 06, 15 02 02, 16 01 03 16 01 19, 16 01 21, 16 01 22, 16 01 99, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 04, 19 12 09, 19 12 10, 19 12 12, 20 01 10, 20 01 11, 20 01 28, 20 01 39, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99, Osady ściekowe, Paliwa stałe: stałe paliwo wtórne (SRF) O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość ogólnego węgla organicznego (TOC)\nZakres:\nZakres (7 – 500) g/kg\nZakres (7 000 – 500 000) mg/kg\nZakres (0,7 – 50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 13137:2004 Odpady O) kod: 02 01 04, 02 07 05, 04 02 21, 04 02 22, 07 02 14, 12 01 05, 15 01 06, 15 02 02, 16 01 03 16 01 19, 16 01 21, 16 01 22, 16 01 99, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 04, 19 12 09, 19 12 10, 19 12 12, 20 01 10, 20 01 11, 20 01 28, 20 01 39, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99, Osady sciekowe, Paliwa stale: stale paliwo wtorne (SRF) O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc ogolnego wegla organicznego (TOC)\nZakres:\nZakres (7 – 500) g/kg\nZakres (7 000 – 500 000) mg/kg\nZakres (0,7 – 50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 13137:2004","categories":["environment","water","petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"总有机碳（TOC）含量","parameters_zh":[{"name":"范围","range":"(7 – 500) g/kg"},{"name":"范围","range":"(7 000 – 500 000) mg/kg"},{"name":"范围","range":"(0,7 – 50) %"}],"search_zh":"总有机碳（TOC）含量 高温燃烧红外检测法 范围 范围 范围 PN-EN 13137:2004","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8f8772289e4f5e07039de1","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 15 01 01, 15 01 02, 15 01 03, 15 01 04, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 17 01 07, 17 09 04, 19 12 10, 19 12 12, 20 01 08, 20 02 01, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 07 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Skład morfologiczny","parameters":[{"name":"Zakres","range":"(0,00 – 100,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Skład morfologiczny\nZakres (0,00 – 100,0) %\nMetoda wagowa","reference":"PN-Z-15006:1993 | ZUO/LAB/PB-53 wydanie 2 z dnia 03.03.2025 r.","norm_bases":["PN-Z-15006:1993","ZUO/LAB/PB-53 wydanie 2 z dnia 03.03.2025 r."],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 15 01 01, 15 01 02, 15 01 03, 15 01 04, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 17 01 07, 17 09 04, 19 12 10, 19 12 12, 20 01 08, 20 02 01, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 07 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Skład morfologiczny\nZakres (0,00 – 100,0) %\nMetoda wagowa PN-Z-15006:1993 | ZUO/LAB/PB-53 wydanie 2 z dnia 03.03.2025 r. Odpady O) kod: 15 01 01, 15 01 02, 15 01 03, 15 01 04, 15 01 05, 15 01 06, 15 01 07, 15 01 09, 17 01 07, 17 09 04, 19 12 10, 19 12 12, 20 01 08, 20 02 01, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 07 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Sklad morfologiczny\nZakres (0,00 – 100,0) %\nMetoda wagowa PN-Z-15006:1993 | ZUO/LAB/PB-53 wydanie 2 z dnia 03.03.2025 r.","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"形态组成","parameters_zh":[{"name":"范围","range":"(0,00 – 100,0) %"}],"search_zh":"形态组成 重量法 范围 PN-Z-15006:1993 | ZUO/LAB/PB-53 wydanie 2 z dnia 03.03.2025 r.","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039de2","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 19 05 03, 19 05 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ZUO/LAB/PB-55 wydanie 2 z dnia 08.01.2014 r.","norm_bases":["ZUO/LAB/PB-55 wydanie 2 z dnia 08.01.2014 r."],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 19 05 03, 19 05 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Pobieranie próbek do badań chemicznych i fizycznych ZUO/LAB/PB-55 wydanie 2 z dnia 08.01.2014 r. Odpady O) kod: 19 05 03, 19 05 99 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Pobieranie probek do badan chemicznych i fizycznych ZUO/LAB/PB-55 wydanie 2 z dnia 08.01.2014 r.","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 ZUO/LAB/PB-55 wydanie 2 z dnia 08.01.2014 r."},{"_id":"6a8f8772289e4f5e07039de3","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 11, 20 01 28, 20 01 39, 20 01 99 ,20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(4 800 – 25 000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (4 800 – 25 000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 11, 20 01 28, 20 01 39, 20 01 99 ,20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Ciepło spalania\nZakres (4 800 – 25 000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 11, 20 01 28, 20 01 39, 20 01 99 ,20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Cieplo spalania\nZakres (4 800 – 25 000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(4 800 – 25 000) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法"},{"_id":"6a8f8772289e4f5e07039de4","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 11, 20 01 28, 20 01 39, 20 01 99 ,20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 11, 20 01 28, 20 01 39, 20 01 99 ,20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15408:2011 Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 11, 20 01 28, 20 01 39, 20 01 99 ,20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc siarki calkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15408:2011","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 PN-EN 15408:2011","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8f8772289e4f5e07039de5","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 28, 20 01 39, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(2,2 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (2,2 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 28, 20 01 39, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wilgoci w próbce analitycznej\nZakres (2,2 – 40,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Odpady O) kod: 04 02 09, 04 02 21, 04 02 22, 12 01 05, 15 01 01, 15 01 02, 15 01 06, 16 01 03, 16 01 09, 16 01 19, 16 01 22, 16 03 04, 16 07 99, 17 01 07, 17 02 03, 17 03 02, 17 06 03, 17 06 04, 17 09 04, 19 01 10, 19 01 11, 19 01 12, 19 01 13, 19 05 01, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 12 09, 19 12 10, 19 12 12, 20 01 28, 20 01 39, 20 01 99, 20 02 03, 20 03 01, 20 03 03, 20 03 06, 20 03 07, 20 03 99 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wilgoci w probce analitycznej\nZakres (2,2 – 40,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(2,2 – 40,0) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039de6","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod: 19 05 99, 19 05 03, 19 12 12 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Aktywność oddychania (AT4)","parameters":[{"name":"Zakres","range":"(2 – 40) mg/g"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"computed":[],"activity":"Aktywność oddychania (AT4)\nZakres (2 – 40) mg/g\nMetoda manometryczna","reference":"ZUO/LAB/PB-51 wydanie 1 z dnia 14.12.2012 r.","norm_bases":["ZUO/LAB/PB-51 wydanie 1 z dnia 14.12.2012 r."],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod: 19 05 99, 19 05 03, 19 12 12 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Aktywność oddychania (AT4)\nZakres (2 – 40) mg/g\nMetoda manometryczna ZUO/LAB/PB-51 wydanie 1 z dnia 14.12.2012 r. Odpady O) kod: 19 05 99, 19 05 03, 19 12 12 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Aktywnosc oddychania (AT4)\nZakres (2 – 40) mg/g\nMetoda manometryczna ZUO/LAB/PB-51 wydanie 1 z dnia 14.12.2012 r.","categories":["environment","metrology"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2 – 40) mg/g"}],"search_zh":"压力计法 范围 ZUO/LAB/PB-51 wydanie 1 z dnia 14.12.2012 r.","technique_zh":"压力计法"},{"_id":"6a8f8772289e4f5e07039de7","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(12,0 – 60,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (12,0 – 60,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość węgla całkowitego\nZakres (12,0 – 60,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wegla calkowitego\nZakres (12,0 – 60,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(12,0 – 60,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8f8772289e4f5e07039de8","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(2,50 – 10,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (2,50 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 21663:2021-06","norm_bases":["PN-EN ISO 21663:2021-06"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wodoru\nZakres (2,50 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 21663:2021-06 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wodoru\nZakres (2,50 – 10,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 21663:2021-06","categories":["environment","petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"氢含量","parameters_zh":[{"name":"范围","range":"(2,50 – 10,00) %"}],"search_zh":"氢含量 高温燃烧红外检测法 范围 PN-EN ISO 21663:2021-06","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8f8772289e4f5e07039de9","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(10 000 – 40 000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (10 000 – 40 000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Ciepło spalania\nZakres (10 000 – 40 000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Cieplo spalania\nZakres (10 000 – 40 000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["environment","petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10 000 – 40 000) kJ/kg"}],"search_zh":"高位发热量 量热法 范围 PN-EN ISO 21654:2021-12","technique_zh":"量热法"},{"_id":"6a8f8772289e4f5e07039dea","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Wartość opałowa (z obliczeń) PN-EN ISO 21654:2021-12 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Wartosc opalowa (z obliczen) PN-EN ISO 21654:2021-12","categories":["environment","petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"低位发热量（计算值）","search_zh":"低位发热量（计算值） PN-EN ISO 21654:2021-12"},{"_id":"6a8f8772289e4f5e07039deb","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość siarki całkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 15408:2011 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc siarki calkowitej\nZakres (0,02 – 1,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 15408:2011","categories":["environment","petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) %"}],"search_zh":"全硫含量 高温燃烧红外检测法 范围 PN-EN 15408:2011","technique_zh":"高温燃烧红外检测法"},{"_id":"6a8f8772289e4f5e07039dec","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,02 – 2,50) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,02 – 2,50) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość siarki całkowitej\nZakres (0,02 – 2,50) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 15408:2011 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc siarki calkowitej\nZakres (0,02 – 2,50) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 15408:2011","categories":["environment","petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,02 – 2,50) %"}],"search_zh":"全硫含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN 15408:2011","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a8f8772289e4f5e07039ded","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość chloru","parameters":[{"name":"Zakres","range":"(0,060 – 1,500) %"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość chloru\nZakres (0,060 – 1,500) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 15408:2011","norm_bases":["PN-EN 15408:2011"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość chloru\nZakres (0,060 – 1,500) %\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 15408:2011 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc chloru\nZakres (0,060 – 1,500) %\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 15408:2011","categories":["environment","petro"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"氯含量","parameters_zh":[{"name":"范围","range":"(0,060 – 1,500) %"}],"search_zh":"氯含量 离子色谱-电导检测法（IC-CD） 范围 PN-EN 15408:2011","technique_zh":"离子色谱-电导检测法（IC-CD）"},{"_id":"6a8f8772289e4f5e07039dee","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,1 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,1 – 60,0) %\nMetoda wagowa","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość popiołu\nZakres (0,1 – 60,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc popiolu\nZakres (0,1 – 60,0) %\nMetoda wagowa PN-EN ISO 21656:2021-08","categories":["environment","petro"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 60,0) %"}],"search_zh":"灰分含量 重量法 范围 PN-EN ISO 21656:2021-08","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039def","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,1 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 40,0) %\nMetoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość wilgoci w próbce analitycznej\nZakres (0,1 – 40,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc wilgoci w probce analitycznej\nZakres (0,1 – 40,0) %\nMetoda wagowa PN-EN ISO 21660-3:2021-08","categories":["environment","petro"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,1 – 40,0) %"}],"search_zh":"分析样品水分含量 重量法 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039df0","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Wilgotność całkowita","parameters":[{"name":"Zakres","range":"(3,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wilgotność całkowita\nZakres (3,0 – 40,0) %\nMetoda wagowa","reference":"SIS CEN/TS 15414-1:2014","norm_bases":["SIS CEN/TS 15414-1:2014"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwo wtórne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Wilgotność całkowita\nZakres (3,0 – 40,0) %\nMetoda wagowa SIS CEN/TS 15414-1:2014 Paliwa stale: stale paliwo wtorne (SRF), Odpady O) kod: 02 01 03, 02 01 04, 02 01 07, 03 01 01, 03 01 05, 03 03 01, 03 03 07, 03 03 08, 04 02 21, 04 02 22, 04 01 99, 04 02 09, 07 02 13, 07 02 80, 15 01 01, 15 01 02, 15 01 03, 15 01 05, 15 01 06, 15 01 09, 15 02 03, 16 01 03, 16 01 19, 16 01 22, 17 02 03, 19 12 01, 19 12 04, 19 12 08, 19 12 12, 20 01 01, 20 01 10, 20 01 11, 20 01 38, 20 01 39, 20 03 07, 20 02 01, 20 03 01 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Wilgotnosc calkowita\nZakres (3,0 – 40,0) %\nMetoda wagowa SIS CEN/TS 15414-1:2014","categories":["environment","petro"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(3,0 – 40,0) %"}],"search_zh":"重量法 范围 SIS CEN/TS 15414-1:2014","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039df1","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"Odpady O) kod E: 02 01, 02 03, 03 01, 03 03, 04 01, 04 02, 07 02, 07 04, 07 06, 08 01, 08 02, 08 03, 08 04, 10 01, 10 03, 10 11, 12 01, 15 01, 15 02 ,16 01, 16 02, 16 03, 16 80, 16 81, 16 82, 17 01, 17 02, 17 03, 17 05, 17 06, 17 08, 17 09, 19 01, 19 02, 19 04, 19 05, 19 08, 19 09, 19 12, 20 01, 20 02, 20 03 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ZUO/LAB/PB-54","norm_bases":["ZUO/LAB/PB-54"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) kod E: 02 01, 02 03, 03 01, 03 03, 04 01, 04 02, 07 02, 07 04, 07 06, 08 01, 08 02, 08 03, 08 04, 10 01, 10 03, 10 11, 12 01, 15 01, 15 02 ,16 01, 16 02, 16 03, 16 80, 16 81, 16 82, 17 01, 17 02, 17 03, 17 05, 17 06, 17 08, 17 09, 19 01, 19 02, 19 04, 19 05, 19 08, 19 09, 19 12, 20 01, 20 02, 20 03 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot. Pobieranie próbek do badań chemicznych i fizycznych ZUO/LAB/PB-54 Odpady O) kod E: 02 01, 02 03, 03 01, 03 03, 04 01, 04 02, 07 02, 07 04, 07 06, 08 01, 08 02, 08 03, 08 04, 10 01, 10 03, 10 11, 12 01, 15 01, 15 02 ,16 01, 16 02, 16 03, 16 80, 16 81, 16 82, 17 01, 17 02, 17 03, 17 05, 17 06, 17 08, 17 09, 19 01, 19 02, 19 04, 19 05, 19 08, 19 09, 19 12, 20 01, 20 02, 20 03 O) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow E – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych. Lista dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana publicznie lub na zadanie przez akredytowany podmiot. Pobieranie probek do badan chemicznych i fizycznych ZUO/LAB/PB-54","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 ZUO/LAB/PB-54"},{"_id":"6a8f8772289e4f5e07039df2","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(1,00 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (1,00 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Straty przy prażeniu suchej masy (LOI)\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01 OdpadyDAB-11: Odpady budowlane (III), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Straty przy prazeniu suchej masy (LOI)\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water","environment","materials","construction"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"干物质烧失量（LOI）","parameters_zh":[{"name":"范围","range":"(1,00 – 90,0) %"}],"search_zh":"干物质烧失量（LOI） 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039df3","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Sucha pozostałość/zawartość wody","parameters":[{"name":"Zakres","range":"(1,00 – 90,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość/zawartość wody\nZakres (1,00 – 90,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Sucha pozostałość/zawartość wody\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A OdpadyDAB-11: Odpady budowlane (III), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Sucha pozostalosc/zawartosc wody\nZakres (1,00 – 90,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water","environment","materials","construction"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(1,00 – 90,0) %"}],"search_zh":"重量法 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法"},{"_id":"6a8f8772289e4f5e07039df4","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organiczny (RWO)","parameters":[{"name":"Zakres","range":"(50,0 – 10000) mg/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organiczny (RWO)\nZakres (50,0 – 10000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999 | PN-EN 12457-4:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organiczny (RWO)\nZakres (50,0 – 10000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 | PN-EN 12457-4:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc ogolnego wegla organicznego (OWO) i rozpuszczonego wegla organiczny (RWO)\nZakres (50,0 – 10000) mg/kg\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999 | PN-EN 12457-4:2006","categories":["water","environment","food","materials","construction"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(50,0 – 10000) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 高温燃烧红外检测法 范围 PN-EN 1484:1999 | PN-EN 12457-4:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"},{"_id":"6a8f8772289e4f5e07039df5","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość cynku","parameters":[{"name":"Zakres","range":"(0,50 – 200) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość cynku\nZakres (0,50 – 200) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 | PN-EN 12457-4:2006","norm_bases":["PN-ISO 8288:2002","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość cynku\nZakres (0,50 – 200) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 | PN-EN 12457-4:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc cynku\nZakres (0,50 – 200) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 | PN-EN 12457-4:2006","categories":["water","environment","food","materials","construction"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"锌含量","parameters_zh":[{"name":"范围","range":"(0,50 – 200) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 锌含量 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 | PN-EN 12457-4:2006","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"},{"_id":"6a8f8772289e4f5e07039df6","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość baru","parameters":[{"name":"Zakres","range":"(10,0 – 300) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość baru\nZakres (10,0 – 300) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006","norm_bases":["ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r.","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość baru\nZakres (10,0 – 300) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc baru\nZakres (10,0 – 300) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006","categories":["water","environment","food","materials","construction"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(10,0 – 300) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 火焰原子吸收光谱法（FAAS） 范围 ZUO/LAB/PB-04 wyd. 4 z dnia 30.01.2023 r. | PN-EN 12457-4:2006","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"},{"_id":"6a8f8772289e4f5e07039df7","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,0050 – 2,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,0050 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość rtęci\nZakres (0,0050 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc rteci\nZakres (0,0050 – 2,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006","categories":["water","environment","food","materials","construction"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,0050 – 2,0) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 | PN-EN 12457-4:2006","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"},{"_id":"6a8f8772289e4f5e07039df8","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość pierwiastków","parameters":[{"name":"Cd","range":"(0,0040 – 5,0) mg/kg"},{"name":"Cr","range":"(0,020 – 70,0) mg/kg"},{"name":"Cu","range":"(0,030 – 100) mg/kg"},{"name":"Pb","range":"(0,10 – 50,0) mg/kg"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCd (0,0040 – 5,0) mg/kg\nCr (0,020 – 70,0) mg/kg\nCu (0,030 – 100) mg/kg\nPb (0,10 – 50,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 15586:2005","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość pierwiastków\nZakres:\nCd (0,0040 – 5,0) mg/kg\nCr (0,020 – 70,0) mg/kg\nCu (0,030 – 100) mg/kg\nPb (0,10 – 50,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc pierwiastkow\nZakres:\nCd (0,0040 – 5,0) mg/kg\nCr (0,020 – 70,0) mg/kg\nCu (0,030 – 100) mg/kg\nPb (0,10 – 50,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","categories":["water","environment","food","materials","construction"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"元素含量","parameters_zh":[{"name":"Cd","range":"(0,0040 – 5,0) mg/kg"},{"name":"Cr","range":"(0,020 – 70,0) mg/kg"},{"name":"Cu","range":"(0,030 – 100) mg/kg"},{"name":"Pb","range":"(0,10 – 50,0) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 元素含量 电热原子化原子吸收光谱法（ETAAS） Cd Cr Cu Pb PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"},{"_id":"6a8f8772289e4f5e07039df9","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość pierwiastków","parameters":[{"name":"As","range":"(0,10 – 25,0) mg/kg"},{"name":"Sb","range":"(0,10 – 5,0) mg/kg"},{"name":"Se","range":"(0,10 – 7,0) mg/kg"},{"name":"Mo","range":"(0,06 – 30,0) mg/kg"},{"name":"Ni","range":"(0,07 – 40,0) mg/kg"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nAs (0,10 – 25,0) mg/kg\nSb (0,10 – 5,0) mg/kg\nSe (0,10 – 7,0) mg/kg\nMo (0,06 – 30,0) mg/kg\nNi (0,07 – 40,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 15586:2005","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość pierwiastków\nZakres:\nAs (0,10 – 25,0) mg/kg\nSb (0,10 – 5,0) mg/kg\nSe (0,10 – 7,0) mg/kg\nMo (0,06 – 30,0) mg/kg\nNi (0,07 – 40,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc pierwiastkow\nZakres:\nAs (0,10 – 25,0) mg/kg\nSb (0,10 – 5,0) mg/kg\nSe (0,10 – 7,0) mg/kg\nMo (0,06 – 30,0) mg/kg\nNi (0,07 – 40,0) mg/kg\nMetoda atomowej spektrometrii absorpcyjnej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","categories":["water","environment","food","materials","construction"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"元素含量","parameters_zh":[{"name":"As","range":"(0,10 – 25,0) mg/kg"},{"name":"Sb","range":"(0,10 – 5,0) mg/kg"},{"name":"Se","range":"(0,10 – 7,0) mg/kg"},{"name":"Mo","range":"(0,06 – 30,0) mg/kg"},{"name":"Ni","range":"(0,07 – 40,0) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 元素含量 电热原子化原子吸收光谱法（ETAAS） As Sb Se Mo Ni PN-EN ISO 15586:2005 | PN-EN 12457-4:2006","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"},{"_id":"6a8f8772289e4f5e07039dfa","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość anionów","parameters":[{"name":"chlorki","range":"(10 – 10000) mg/kg"},{"name":"fluorki","range":"(1,0 – 200) mg/kg"},{"name":"siarczany","range":"(10 – 10000) mg/kg"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość anionów\nZakres:\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 200) mg/kg\nsiarczany (10 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN 12457-4:2006","PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość anionów\nZakres:\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 200) mg/kg\nsiarczany (10 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc anionow\nZakres:\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 200) mg/kg\nsiarczany (10 – 10000) mg/kg\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","categories":["water","environment","food","materials","construction"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"阴离子含量","parameters_zh":[{"name":"氯化物","range":"(10 – 10000) mg/kg"},{"name":"氟化物","range":"(1,0 – 200) mg/kg"},{"name":"硫酸盐","range":"(10 – 10000) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 阴离子含量 离子色谱-电导检测法（IC-CD） 氯化物 氟化物 硫酸盐 PN-EN 12457-4:2006 | PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"},{"_id":"6a8f8772289e4f5e07039dfb","lab_id":"69ad52a3de79e566650fb3dc","country":"PL","accr_number":"AB 769","accr_body":"PCA","test_object":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","methodology":"Zawartość całkowitych substancji rozpuszczonych (TDS)","parameters":[{"name":"Zakres","range":"(2000 – 152 400) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość całkowitych substancji rozpuszczonych (TDS)\nZakres (2000 – 152 400) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-4:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-4:2006"],"lab_section":"Laboratorium; Stanowice 29, 66-450 Bogdaniec","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: Rozporządzeniem Ministra Gospodarki z dnia 16 lipca 2015 roku w sprawie dopuszczania odpadów do składowania na składowiskach (Dz. U. z 2015, poz. 1277)","flexible":false,"search_text":"OdpadyDAB-11: Odpady budowlane (III), Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV), Odpady z przetwarzania odpadów (VI), Osady z procesów przemysłowych (VII), Osady ściekowe (IX), Żużle, popioły i pyły paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powłok ochronnych, klejów i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skóry i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość całkowitych substancji rozpuszczonych (TDS)\nZakres (2000 – 152 400) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-4:2006 OdpadyDAB-11: Odpady budowlane (III), Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV), Odpady z przetwarzania odpadow (VI), Osady z procesow przemyslowych (VII), Osady sciekowe (IX), Zuzle, popioly i pyly paleniskowe (XI), Odpady chemiczne - organiczne zmieszane (XIV), Odpady z produkcji i stosowania powlok ochronnych, klejow i farb (XVI), Odpady szklane (XXIII), Papier i tektura (XXIV), Tworzywa sztuczne (XXV), Drewno (XXVI), Skory i tekstylia (XXVII), Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc calkowitych substancji rozpuszczonych (TDS)\nZakres (2000 – 152 400) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-4:2006","categories":["water","environment","food","materials","construction"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(2000 – 152 400) mg/kg"}],"search_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII） 重量法 范围 PN-EN 15216:2022-03 | PN-EN 12457-4:2006","technique_zh":"重量法","test_object_zh":"废物DAB-11：建筑废物（III），植物性、动物性与食品加工废物（IV），废物处理产生的废物（VI），工业过程污泥（VII），污水污泥（IX），炉渣、灰与炉膛粉尘（XI），化学废物 － 有机混合物（XIV），防护涂层、胶粘剂与油漆生产及使用产生的废物（XVI），玻璃废物（XXIII），纸与纸板（XXIV），塑料（XXV），木材（XXVI），皮革与纺织品（XXVII），其他生活废物及源自生活废物的废物，含混合废物，以及污水处理与水净化产生的其他废物（XXVIII）"}],"has_pdf":true}