{"lab":{"_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","address":"W BRZOZOWIE, ul. Moniuszki 17, 36-200 Brzozów","categories":["water","environment","microbiology"],"city":"Brzozów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":34,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_755.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w brzozowie, ul. moniuszki 17, 36-200 brzozów other water microbiology automotive metrology pharma electronics environment","status":"active","updated_at":"2026-03-08T14:51:38.763Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:11:28.670Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20755,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe - oświetlenie, drgania, hałas","en":"Tests concerning environmental engineering (enviromental and climatic) – working environmental (harmful and nuisance factors – noise, lighting, vibration)"},{"codes":"K/3; K/28; K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, water, drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of phisical properties of water, drinking water"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek powietrza środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of phisical properties and sampling – working environment (harmful factors – air)"}],"issue":{"no":"25","date":"07.08.2026"},"parse_date":"2026-08-13T08:11:28.670Z","parse_source":"agent-claude-code","map_coord":[49.692289,22.008721],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ LABORATORYJNY","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Bakteriologii Wody","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Fizykochemii Wody","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Higieny Pracy","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Bakteriologii Schorzeń Jelitowych","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Schorzeń Jelitowych","address":null,"city":null,"postal":null},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","address":null,"city":null,"postal":null},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","address":null,"city":null,"postal":null},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/04e8d6ba4623b0c39120a097ce3b7309/AB%20755.pdf","has_en":true,"category_counts":{"water":17,"environment":12,"microbiology":5,"other":4},"category_scores":{"water":7.61,"environment":3.79,"microbiology":0.66,"other":0.42},"has_zh":true,"lab_locations_zh":[{"name":"ODDZIAŁ LABORATORYJNY","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Bakteriologii Wody","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Fizykochemii Wody","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Higieny Pracy","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"Pracownia Bakteriologii Schorzeń Jelitowych","address":"ul. Moniuszki 17, 36-200 Brzozów","city":"Brzozów","postal":"36-200"},{"name":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Schorzeń Jelitowych","address":null,"city":null,"postal":null},{"name":"实验室分部；水细菌学检验室","address":null,"city":null,"postal":null},{"name":"实验室分部；水理化检验室","address":null,"city":null,"postal":null},{"name":"实验室分部；职业卫生实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7c300636ba417e41c342","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Total viable count at 22 °C","search_en":"Water, Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) LABORATORY DIVISION; Water Bacteriology Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） 实验室分部；水细菌学检验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c343","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PB/06/M wyd. V z dnia 07.03.2025","PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method LABORATORY DIVISION; Water Bacteriology Laboratory PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 实验室分部；水细菌学检验室 PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c344","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli termotolerancyjnych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli termotolerancyjnych\nMetoda filtracji membranowej","reference":"PB/06/M wyd. V z dnia 07.03.2025","norm_bases":["PB/06/M wyd. V z dnia 07.03.2025"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli termotolerancyjnych\nMetoda filtracji membranowej PB/06/M wyd. V z dnia 07.03.2025 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli termotolerancyjnych\nMetoda filtracji membranowej PB/06/M wyd. V z dnia 07.03.2025","categories":["water","microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Count of thermotolerant coliform bacteria","search_en":"Water, Water intended for human consumption Count of thermotolerant coliform bacteria Membrane filtration method LABORATORY DIVISION; Water Bacteriology Laboratory PB/06/M wyd. V z dnia 07.03.2025","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 实验室分部；水细菌学检验室 PB/06/M wyd. V z dnia 07.03.2025","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c345","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PB/06/M wyd. V z dnia 07.03.2025","PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method LABORATORY DIVISION; Water Bacteriology Laboratory PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室分部；水细菌学检验室 PB/06/M wyd. V z dnia 07.03.2025 | PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c346","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2: 2004","norm_bases":["PN-EN ISO 7899-2: 2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2: 2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2: 2004","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Enterococci count","search_en":"Water, Water intended for human consumption Enterococci count Membrane filtration method LABORATORY DIVISION; Water Bacteriology Laboratory PN-EN ISO 7899-2: 2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"肠球菌计数","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 实验室分部；水细菌学检验室 PN-EN ISO 7899-2: 2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c347","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Total viable count at 36 °C","search_en":"Swimming pool water Total viable count at 36 °C Plate method (pour plate) LABORATORY DIVISION; Water Bacteriology Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Swimming pool water","methodology_zh":"36 °C 微生物总数","search_zh":"游泳池水 36 °C 微生物总数 平板法（倾注培养） 实验室分部；水细菌学检验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c348","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Escherichia coli count","search_en":"Swimming pool water Escherichia coli count Membrane filtration method LABORATORY DIVISION; Water Bacteriology Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室分部；水细菌学检验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c349","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Bacteriology Laboratory","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method LABORATORY DIVISION; Water Bacteriology Laboratory PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 实验室分部；水细菌学检验室 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水","lab_section_zh":"实验室分部；水细菌学检验室"},{"_id":"6a7d7c300636ba417e41c34a","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Badane obiekty / Grupa obiektów","methodology":"Badane cechy i metody badawcze/pomiarowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badane cechy i metody badawcze/pomiarowe","reference":"Normy i/lub udokumentowane procedury badawcze","norm_bases":["Normy i/lub udokumentowane procedury badawcze"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Badane obiekty / Grupa obiektów Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze Badane obiekty / Grupa obiektow Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Characteristics tested and test/measurement methods","search_en":"Test objects / Group of objects Characteristics tested and test/measurement methods LABORATORY DIVISION; Water Physicochemistry Laboratory Normy i/lub udokumentowane procedury badawcze","test_object_en":"Test objects / Group of objects","lab_section_zh":"实验室分部；水理化检验室","search_zh":"受检对象/对象组 受检特性与检验/测量方法 实验室分部；水理化检验室 Normy i/lub udokumentowane procedury badawcze","test_object_zh":"受检对象/对象组","methodology_zh":"受检特性与检验/测量方法"},{"_id":"6a7d7c300636ba417e41c34b","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,040 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,040 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,040 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,040 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,040 – 2,0) mg/l"}],"search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 实验室分部；水理化检验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c34c","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 – 1,5) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 – 1,5) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-92/C-04590/03","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 1,5) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 实验室分部；水理化检验室 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c34d","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,020 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,020 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 实验室分部；水理化检验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c34e","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,13 – 2,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,13 – 2,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,13 – 2,6) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,13 – 2,6) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,13 – 2,6) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,13 – 2,6) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 实验室分部；水理化检验室 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c34f","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,18 – 110) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,18 – 110) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,18 – 110) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,18 – 110) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,18 – 110) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,18 – 110) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 实验室分部；水理化检验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c350","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(148 – 12800) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (148 – 12800) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (148 – 12800) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (148 – 12800) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(148 – 12800) μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(148 – 12800) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 实验室分部；水理化检验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c351","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 实验室分部；水理化检验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c352","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 20) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 20) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 实验室分部；水理化检验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c353","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 60) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 60) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887: 2012 + Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887: 2012 + Ap1:2015-06 Metoda D"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Fizykochemii Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 60) mg/l Pt\nMetoda wizualna PN-EN ISO 7887: 2012 + Ap1:2015-06 Metoda D Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 60) mg/l Pt\nMetoda wizualna PN-EN ISO 7887: 2012 + Ap1:2015-06 Metoda D","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Water Physicochemistry Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 60) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Visual method LABORATORY DIVISION; Water Physicochemistry Laboratory Range PN-EN ISO 7887: 2012 + Ap1:2015-06 Metoda D","technique_en":"Visual method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 60) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 实验室分部；水理化检验室 范围 PN-EN ISO 7887: 2012 + Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室分部；水理化检验室"},{"_id":"6a7d7c300636ba417e41c354","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Badane obiekty / Grupa obiektów","methodology":"Badane cechy i metody badawcze/pomiarowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badane cechy i metody badawcze/pomiarowe","reference":"Normy i/lub udokumentowane procedury badawcze","norm_bases":["Normy i/lub udokumentowane procedury badawcze"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Badane obiekty / Grupa obiektów Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze Badane obiekty / Grupa obiektow Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Characteristics tested and test/measurement methods","search_en":"Test objects / Group of objects Characteristics tested and test/measurement methods LABORATORY DIVISION; Occupational Hygiene Laboratory Normy i/lub udokumentowane procedury badawcze","test_object_en":"Test objects / Group of objects","lab_section_zh":"实验室分部；职业卫生实验室","search_zh":"受检对象/对象组 受检特性与检验/测量方法 实验室分部；职业卫生实验室 Normy i/lub udokumentowane procedury badawcze","test_object_zh":"受检对象/对象组","methodology_zh":"受检特性与检验/测量方法"},{"_id":"6a7d7c300636ba417e41c355","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,06 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,06 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,06 – 100) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method LABORATORY DIVISION; Occupational Hygiene Laboratory Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,06 – 100) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 实验室分部；职业卫生实验室 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c356","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godz działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godz działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godz działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godz dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for an 8-h working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for an 8-h working day of the vector sum of the frequency-corrected r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the frequency-weighted r.m.s. vibration accelerations, determined for the three directional components (ahwx, ahwy, ahwz) (calculated) LABORATORY DIVISION; Occupational Hygiene Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","search_zh":"工作场所环境 — 手传振动 实验室分部；职业卫生实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c357","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 100) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method LABORATORY DIVISION; Occupational Hygiene Laboratory Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 100) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 实验室分部；职业卫生实验室 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c358","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godz działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godz działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godz działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godz dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) LABORATORY DIVISION; Occupational Hygiene Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","search_zh":"工作场所环境 — 全身振动 实验室分部；职业卫生实验室 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c359","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Badane obiekty / Grupa obiektów","methodology":"Badane cechy i metody badawcze/pomiarowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badane cechy i metody badawcze/pomiarowe","reference":"Normy i/lub udokumentowane procedury badawcze","norm_bases":["Normy i/lub udokumentowane procedury badawcze"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Badane obiekty / Grupa obiektów Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze Badane obiekty / Grupa obiektow Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Characteristics tested and test/measurement methods","search_en":"Test objects / Group of objects Characteristics tested and test/measurement methods LABORATORY DIVISION; Occupational Hygiene Laboratory Normy i/lub udokumentowane procedury badawcze","test_object_en":"Test objects / Group of objects","lab_section_zh":"实验室分部；职业卫生实验室","search_zh":"受检对象/对象组 受检特性与检验/测量方法 实验室分部；职业卫生实验室 Normy i/lub udokumentowane procedury badawcze","test_object_zh":"受检对象/对象组","methodology_zh":"受检特性与检验/测量方法"},{"_id":"6a7d7c300636ba417e41c35a","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,","parameters":[{"name":"Zakres","range":"(40 – 137) dB"},{"name":"Szczytowy poziom dźwięku C,"},{"name":"Zakres","range":"(40 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,\nZakres:\nZakres (40 – 137) dB\nSzczytowy poziom dźwięku C,\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,\nZakres:\nZakres (40 – 137) dB\nSzczytowy poziom dźwięku C,\nZakres (40 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A, Maksymalny poziom dzwieku A,\nZakres:\nZakres (40 – 137) dB\nSzczytowy poziom dzwieku C,\nZakres (40 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"A-weighted equivalent sound level, Maximum A-weighted sound level,","parameters_en":[{"name":"Range","range":"(40 – 137) dB"},{"name":"C-weighted peak sound pressure level,"},{"name":"Range","range":"(40 – 140) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level, Maximum A-weighted sound level, Direct measurement method LABORATORY DIVISION; Occupational Hygiene Laboratory Range C-weighted peak sound pressure level, Range PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","parameters_zh":[{"name":"范围","range":"(40 – 137) dB"},{"name":"C 计权峰值声级，"},{"name":"范围","range":"(40 – 140) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级、A 计权最大声级， 直接测量法 实验室分部；职业卫生实验室 范围 C 计权峰值声级， 范围 PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"实验室分部；职业卫生实验室","methodology_zh":"A 计权等效声级、A 计权最大声级，"},{"_id":"6a7d7c300636ba417e41c35b","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: LABORATORY DIVISION; Occupational Hygiene Laboratory 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8-godz. dobowego wymiaru czasu"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 实验室分部；职业卫生实验室 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612: 2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c35c","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 5 000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method LABORATORY DIVISION; Occupational Hygiene Laboratory Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 实验室分部；职业卫生实验室 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c35d","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) LABORATORY DIVISION; Occupational Hygiene Laboratory PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） 实验室分部；职业卫生实验室 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c35e","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne, w tym:"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym:\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym:\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne, w tym:\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances, including:"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method LABORATORY DIVISION; Occupational Hygiene Laboratory dust agents inhalable fraction respirable fraction inorganic substances, including: respirable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质，其中包括："},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 实验室分部；职业卫生实验室 粉尘因素 可吸入组分 呼吸性组分 无机物质，其中包括： 呼吸性组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室","methodology_zh":"职业接触评估采样，针对："},{"_id":"6a7d7c300636ba417e41c35f","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) LABORATORY DIVISION; Occupational Hygiene Laboratory PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 实验室分部；职业卫生实验室 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c360","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,18 – 20) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,18 – 20) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,18 – 20) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,18 – 20) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,18 – 20) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method LABORATORY DIVISION; Occupational Hygiene Laboratory Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,18 – 20) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 实验室分部；职业卫生实验室 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c361","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,13 – 21) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,13 – 21) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Higieny Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,13 – 21) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,13 – 21) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Occupational Hygiene Laboratory","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,13 – 21) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method LABORATORY DIVISION; Occupational Hygiene Laboratory Organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,13 – 21) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 实验室分部；职业卫生实验室 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分","lab_section_zh":"实验室分部；职业卫生实验室"},{"_id":"6a7d7c300636ba417e41c362","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Badane obiekty / Grupa obiektów","methodology":"Badane cechy i metody badawcze/pomiarowe","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badane cechy i metody badawcze/pomiarowe","reference":"Normy i/lub udokumentowane procedury badawcze","norm_bases":["Normy i/lub udokumentowane procedury badawcze"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Schorzeń Jelitowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Badane obiekty / Grupa obiektów Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze Badane obiekty / Grupa obiektow Badane cechy i metody badawcze/pomiarowe Normy i/lub udokumentowane procedury badawcze","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Intestinal Diseases Bacteriology Laboratory","methodology_en":"Characteristics tested and test/measurement methods","search_en":"Test objects / Group of objects Characteristics tested and test/measurement methods LABORATORY DIVISION; Intestinal Diseases Bacteriology Laboratory Normy i/lub udokumentowane procedury badawcze","test_object_en":"Test objects / Group of objects","search_zh":"受检对象/对象组 受检特性与检验/测量方法 Normy i/lub udokumentowane procedury badawcze","test_object_zh":"受检对象/对象组","methodology_zh":"受检特性与检验/测量方法"},{"_id":"6a7d7c300636ba417e41c363","lab_id":"69ad52a3de79e566650fb3ca","country":"PL","accr_number":"AB 755","accr_body":"PCA","test_object":"Wymaz z odbytu, kał","methodology":"Obecność pałeczek Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/03/M wydanie VII z dnia 20.03.2026","norm_bases":["PB/03/M wydanie VII z dnia 20.03.2026"],"lab_section":"ODDZIAŁ LABORATORYJNY; Pracownia Bakteriologii Schorzeń Jelitowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wymaz z odbytu, kał Obecność pałeczek Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/03/M wydanie VII z dnia 20.03.2026 Wymaz z odbytu, kal Obecnosc paleczek Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/03/M wydanie VII z dnia 20.03.2026","categories":["microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DIVISION; Intestinal Diseases Bacteriology Laboratory","methodology_en":"Presence of Salmonella and Shigella rods","search_en":"Rectal swab, faeces Presence of Salmonella and Shigella rods Culture method with biochemical and serological confirmation LABORATORY DIVISION; Intestinal Diseases Bacteriology Laboratory PB/03/M wydanie VII z dnia 20.03.2026","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Rectal swab, faeces","search_zh":"培养法结合生化与血清学确认 PB/03/M wydanie VII z dnia 20.03.2026","technique_zh":"培养法结合生化与血清学确认"}],"has_pdf":true}