{"lab":{"_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","address":"BEZPIECZEŃSTWEM PRACY, ul. Sandomierska 40, 27-400 Ostrowiec Świętokrzyski","categories":["environment"],"city":"Ostrowiec Świętokrzyski","imported_at":"2026-03-08T10:42:43.265Z","methods_count":51,"name":"Paweł Lisowski EKSPERCKIE BIURO ZARZĄDZANIA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_752.pdf"],"scope_summary":"","search_text":"paweł lisowski eksperckie biuro zarządzania bezpieczeństwem pracy, ul. sandomierska 40, 27-400 ostrowiec świętokrzyski environment other metrology materials construction electronics pharma automotive","status":"active","updated_at":"2026-03-08T14:51:38.594Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:08:18.876Z","email_confidence":"high","email_mx":true,"email_source":"https://ebzbp.pl/","fields_of_testing":[{"codes":"A/5","pl":"Badania akustyczne i drgań – obiekty budowlane (pomieszczenia)","en":"Acoustic and vibration tests of building items (facilities)"},{"codes":"A/19","pl":"Badania akustyczne i drgań - środki ochrony osobistej (ochronniki słuchu)","en":"Acoustic and vibration tests: personal protection equipment"},{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, mikroklimat, pole elektromagnetyczne, nielaserowe promieniowanie optyczne)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors - noise, facilities noise, lighting, vibration, microclimate, electroma- gnetic field, non-laser optical radiation)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/33","pl":"Badania właściwości fizycznych – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties - working environment (harmful factors - air)"},{"codes":"N/35","pl":"Badania właściwości fizycznych – pomieszczenia czyste","en":"Tests of physical properties – clean rooms"},{"codes":"N/40","pl":"Badania właściwości fizycznych – komory laminarne","en":"Tests of physical properties – laminar chambers"},{"codes":"N/41","pl":"Badania właściwości fizycznych – filtry powietrza","en":"Tests of physical properties – air filters"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"26","date":"08.07.2026"},"parse_date":"2026-08-18T01:08:18.876Z","parse_source":"agent-claude-code","map_coord":[50.926534,21.392157],"map_geo":"nominatim-street","lab_locations":[{"name":"Sekcja Badań Środowiska Pracy","address":"ul. Sandomierska 40, 27-400 Ostrowiec Świętokrzyski","city":"Ostrowiec Świętokrzyski","postal":"27-400"},{"name":"Sekcja Badań Pomieszczeń Czystych","address":"ul. Warszawska 31, 05-092 Łomianki","city":"Łomianki","postal":"05-092"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/2a08eebcab574751330c66a5a5df7116/AB%20752.pdf","has_en":true,"category_counts":{"environment":48,"other":3,"construction":2,"materials":1},"category_scores":{"environment":42.67,"other":0.17,"construction":0.07,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a83b082af14b9c0e7b20743","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,","parameters":[{"name":"Zakres","range":"(35 - 135) dB"},{"name":"Szczytowy poziom dźwięku C,"},{"name":"Zakres","range":"(40 - 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,\nZakres:\nZakres (35 - 135) dB\nSzczytowy poziom dźwięku C,\nZakres (40 - 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11","PN-N-01307:1994"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A, Maksymalny poziom dźwięku A,\nZakres:\nZakres (35 - 135) dB\nSzczytowy poziom dźwięku C,\nZakres (40 - 138) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994 Srodowisko pracy - halas Rownowazny poziom dzwieku A, Maksymalny poziom dzwieku A,\nZakres:\nZakres (35 - 135) dB\nSzczytowy poziom dzwieku C,\nZakres (40 - 138) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 3 - punkt 11 | PN-N-01307:1994","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level, Maximum A-weighted sound level,","parameters_en":[{"name":"Range","range":"(35 - 135) dB"},{"name":"C-weighted peak sound pressure level,"},{"name":"Range","range":"(40 - 138) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level, Maximum A-weighted sound level, Direct measurement method Range C-weighted peak sound pressure level, Range PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","parameters_zh":[{"name":"范围","range":"(35 - 135) dB"},{"name":"C 计权峰值声级，"},{"name":"范围","range":"(40 - 138) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级、A 计权最大声级， 直接测量法 范围 C 计权峰值声级， 范围 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"A 计权等效声级、A 计权最大声级，"},{"_id":"6a83b082af14b9c0e7b20744","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11","PN-N-01307:1994"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 3 - punkt 11 | PN-N-01307:1994","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 - punkt 11 | PN-N-01307:1994","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b082af14b9c0e7b20745","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy − ochronniki słuchu","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych","parameters":[{"name":"Zakres","range":"(63 - 8000) Hz"},{"name":"Zakres","range":"(35 - 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych\nZakres:\nZakres (63 - 8000) Hz\nZakres (35 - 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12","norm_bases":["PN-EN 458:2016","PN-EN ISO 4869-2:2018-12"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − ochronniki słuchu Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych\nZakres:\nZakres (63 - 8000) Hz\nZakres (35 - 138) dB\nMetoda pomiarowa bezpośrednia PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12 Srodowisko pracy − ochronniki sluchu Rownowazny poziom cisnienia akustycznego w pasmach czestotliwosciowych oktawowych\nZakres:\nZakres (63 - 8000) Hz\nZakres (35 - 138) dB\nMetoda pomiarowa bezposrednia PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure level in octave frequency bands","parameters_en":[{"name":"Range","range":"(63 - 8000) Hz"},{"name":"Range","range":"(35 - 138) dB"}],"search_en":"Workplace environment − hearing protectors Equivalent sound pressure level in octave frequency bands Direct measurement method Range Range PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hearing protectors","parameters_zh":[{"name":"范围","range":"(63 - 8000) Hz"},{"name":"范围","range":"(35 - 138) dB"}],"search_zh":"倍频程频带等效声压级 直接测量法 范围 范围 PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12","technique_zh":"直接测量法","methodology_zh":"倍频程频带等效声压级"},{"_id":"6a83b082af14b9c0e7b20746","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy − ochronniki słuchu","methodology":"Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","reference":"PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12","norm_bases":["PN-EN 458:2016","PN-EN ISO 4869-2:2018-12"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − ochronniki słuchu Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń) PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12 Srodowisko pracy − ochronniki sluchu Rownowazny poziom dzwieku A pod ochronnikami sluchu (z obliczen) PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level under hearing protectors (calculated)","search_en":"Workplace environment − hearing protectors A-weighted equivalent sound level under hearing protectors (calculated) PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12","test_object_en":"Workplace environment − hearing protectors","methodology_zh":"佩戴听力护具下的 A 计权等效声级（由计算得出）","search_zh":"佩戴听力护具下的 A 计权等效声级（由计算得出） PN-EN 458:2016 | PN-EN ISO 4869-2:2018-12"},{"_id":"6a83b082af14b9c0e7b20747","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło- wych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 - 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło- wych Równoważny poziom dźwięku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslo- wych Rownowazny poziom dzwieku A\nZakres (25 - 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 - 135) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 - 135) dB"}],"search_zh":"一般环境 － 来自装置、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 － 来自装置、设备与工业企业的噪声"},{"_id":"6a83b082af14b9c0e7b20748","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło- wych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysło- wych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslo- wych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 － 来自装置、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) - z wyłączeniem punktu F","test_object_zh":"一般环境 － 来自装置、设备与工业企业的噪声"},{"_id":"6a83b082af14b9c0e7b20749","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,04 - 20) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,04 - 20) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,04 - 20) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,04 - 20) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,04 - 20) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,04 - 20) m/s2"}],"search_zh":"工作环境 － 对人体产生全身作用的振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a83b082af14b9c0e7b2074a","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygo- wanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składo- wych kierunkowych z uwzględnieniem wła- ściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważone- go częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygo- wanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składo- wych kierunkowych z uwzględnieniem wła- ściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważone- go częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygo- wanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składo- wych kierunkowych z uwzględnieniem wła- ściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważone- go częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygo- wanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech sklado- wych kierunkowych z uwzglednieniem wla- sciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazone- go czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment - whole-body vibration PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","search_zh":"工作环境 － 对人体产生全身作用的振动 PN-EN 14253+A1:2011","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a83b082af14b9c0e7b2074b","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,04 - 20) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,04 - 20) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/ A1:2015-11"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,04 - 20) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,04 - 20) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,04 - 20) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,04 - 20) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a83b082af14b9c0e7b2074c","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej sku- tecznych, skorygowanych częstotliwościwo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wekto- rowej skutecznych, ważonych częstotliwo- ściowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej sku- tecznych, skorygowanych częstotliwościwo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wekto- rowej skutecznych, ważonych częstotliwo- ściowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/ A1:2015-11"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej sku- tecznych, skorygowanych częstotliwościwo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wekto- rowej skutecznych, ważonych częstotliwo- ściowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej sku- tecznych, skorygowanych czestotliwosciwo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wekto- rowej skutecznych, wazonych czestotliwo- sciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment - hand-arm vibration PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/ A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a83b082af14b9c0e7b2074d","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5,0 - 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5,0 - 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"EB3b-002 wydanie IV z dnia 20.10.2024 r.","norm_bases":["EB3b-002 wydanie IV z dnia 20.10.2024 r."],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5,0 - 5000) lx\nMetoda pomiarowa bezpośrednia EB3b-002 wydanie IV z dnia 20.10.2024 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5,0 - 5000) lx\nMetoda pomiarowa bezposrednia EB3b-002 wydanie IV z dnia 20.10.2024 r.","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5,0 - 5000) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range EB3b-002 wydanie IV z dnia 20.10.2024 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5,0 - 5000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 EB3b-002 wydanie IV z dnia 20.10.2024 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a83b082af14b9c0e7b2074e","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"EB3b-002 wydanie IV z dnia 20.10.2024 r.","norm_bases":["EB3b-002 wydanie IV z dnia 20.10.2024 r."],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) EB3b-002 wydanie IV z dnia 20.10.2024 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) EB3b-002 wydanie IV z dnia 20.10.2024 r.","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) EB3b-002 wydanie IV z dnia 20.10.2024 r.","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） EB3b-002 wydanie IV z dnia 20.10.2024 r.","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a83b082af14b9c0e7b2074f","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe frakcja wdychalna frakcja respirabilna"},{"name":"substancje organiczne, w tym frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna"},{"name":"metale i ich związki, w tym frakcja wdychalna frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe frakcja wdychalna frakcja respirabilna\nsubstancje organiczne, w tym frakcja wdychalna\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nmetale i ich zwiazki, w tym frakcja wdychalna frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents inhalable fraction respirable fraction"},{"name":"organic substances, including inhalable fraction"},{"name":"inorganic substances, including inhalable fraction respirable fraction thoracic fraction"},{"name":"metals and their compounds, including inhalable fraction respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因子 可吸入性粉尘 呼吸性粉尘 有机物质，其中包括可吸入性粉尘 无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘 金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"粉尘因子 可吸入性粉尘 呼吸性粉尘"},{"name":"有机物质，其中包括可吸入性粉尘"},{"name":"无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘"},{"name":"金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘"}]},{"_id":"6a83b082af14b9c0e7b20750","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b082af14b9c0e7b20751","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:","parameters":[{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"ditlenek tytanu"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"grafit syntetyczny"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"apatyty i fosforyty"},{"name":"pyły mąki"},{"name":"grafit naturalny"},{"name":"sadza techniczna"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"cement portlandzki"},{"name":"pyły drewna"},{"name":"węgiel (kamienny, brunatny)"},{"name":"kaolin"},{"name":"pyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,14 - 20,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\nditlenek tytanu\nsiarczan (VI) wapnia (gips)\ngrafit syntetyczny\nwęglan magnezu wapnia (dolomit)\napatyty i fosforyty\npyły mąki\ngrafit naturalny\nsadza techniczna\nkrzemionka bezpostaciowa i syntetyczna\ncement portlandzki\npyły drewna\nwęgiel (kamienny, brunatny)\nkaolin\npyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,14 - 20,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\npyły niesklasyfikowane ze względu na toksyczność\nditlenek tytanu\nsiarczan (VI) wapnia (gips)\ngrafit syntetyczny\nwęglan magnezu wapnia (dolomit)\napatyty i fosforyty\npyły mąki\ngrafit naturalny\nsadza techniczna\nkrzemionka bezpostaciowa i syntetyczna\ncement portlandzki\npyły drewna\nwęgiel (kamienny, brunatny)\nkaolin\npyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,14 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\npyly niesklasyfikowane ze wzgledu na toksycznosc\nditlenek tytanu\nsiarczan (VI) wapnia (gips)\ngrafit syntetyczny\nweglan magnezu wapnia (dolomit)\napatyty i fosforyty\npyly maki\ngrafit naturalny\nsadza techniczna\nkrzemionka bezpostaciowa i syntetyczna\ncement portlandzki\npyly drewna\nwegiel (kamienny, brunatny)\nkaolin\npyly organiczne pochodzenia zwierzece- go i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,14 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction:","parameters_en":[{"name":"dusts not classified according to toxicity"},{"name":"titanium dioxide"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"synthetic graphite"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"apatites and phosphorites"},{"name":"flour dusts"},{"name":"natural graphite"},{"name":"carbon black"},{"name":"amorphous and synthetic silica"},{"name":"portland cement"},{"name":"wood dusts"},{"name":"coal (hard, brown)"},{"name":"kaolin"},{"name":"pyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Range","range":"(0,14 - 20,4) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction: Gravimetric method dusts not classified according to toxicity titanium dioxide calcium sulfate (VI) (gypsum) synthetic graphite calcium magnesium carbonate (dolomite) apatites and phosphorites flour dusts natural graphite carbon black amorphous and synthetic silica portland cement wood dusts coal (hard, brown) kaolin Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"未按毒性分类的粉尘"},{"name":"二氧化钛"},{"name":"硫酸钙（VI）（石膏）"},{"name":"合成石墨"},{"name":"碳酸钙镁（白云石）"},{"name":"磷灰石与磷块岩"},{"name":"面粉粉尘"},{"name":"天然石墨"},{"name":"炭黑"},{"name":"无定形与合成二氧化硅"},{"name":"硅酸盐水泥"},{"name":"木粉尘"},{"name":"煤（烟煤、褐煤）"},{"name":"高岭土"},{"name":"pyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"范围","range":"(0,14 - 20,4) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 未按毒性分类的粉尘 二氧化钛 硫酸钙（VI）（石膏） 合成石墨 碳酸钙镁（白云石） 磷灰石与磷块岩 面粉粉尘 天然石墨 炭黑 无定形与合成二氧化硅 硅酸盐水泥 木粉尘 煤（烟煤、褐煤） 高岭土 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83b082af14b9c0e7b20752","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:","parameters":[{"name":"apatyty i fosforyty"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"cement portlandzki"},{"name":"węgiel (kamienny, brunatny)"},{"name":"pyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,15 - 14,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\napatyty i fosforyty\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\ncement portlandzki\nwęgiel (kamienny, brunatny)\npyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,15 - 14,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\napatyty i fosforyty\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\ncement portlandzki\nwęgiel (kamienny, brunatny)\npyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,15 - 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\napatyty i fosforyty\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\ncement portlandzki\nwegiel (kamienny, brunatny)\npyly organiczne pochodzenia zwierzece- go i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,15 - 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction:","parameters_en":[{"name":"apatites and phosphorites"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"portland cement"},{"name":"coal (hard, brown)"},{"name":"pyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Range","range":"(0,15 - 14,6) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction: Gravimetric method apatites and phosphorites natural graphite amorphous and synthetic silica portland cement coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"硅酸盐水泥"},{"name":"煤（烟煤、褐煤）"},{"name":"pyły organiczne pochodzenia zwierzęce- go i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"范围","range":"(0,15 - 14,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 磷灰石与磷块岩 天然石墨 无定形与合成二氧化硅 硅酸盐水泥 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a83b082af14b9c0e7b20753","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 - 117) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres (2,3 - 117) mg/m3\nMetoda elektrochemiczna","reference":"EB3b-003 wydanie V z dnia 26.04.2017 r.","norm_bases":["EB3b-003 wydanie V z dnia 26.04.2017 r."],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres (2,3 - 117) mg/m3\nMetoda elektrochemiczna EB3b-003 wydanie V z dnia 26.04.2017 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres (2,3 - 117) mg/m3\nMetoda elektrochemiczna EB3b-003 wydanie V z dnia 26.04.2017 r.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 - 117) mg/m3"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range EB3b-003 wydanie V z dnia 26.04.2017 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(2,3 - 117) mg/m3"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 EB3b-003 wydanie V z dnia 26.04.2017 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a83b082af14b9c0e7b20754","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"EB3b-003 wydanie V z dnia 26.04.2017 r.","norm_bases":["EB3b-003 wydanie V z dnia 26.04.2017 r."],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) EB3b-003 wydanie V z dnia 26.04.2017 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) EB3b-003 wydanie V z dnia 26.04.2017 r.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) EB3b-003 wydanie V z dnia 26.04.2017 r.","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） EB3b-003 wydanie V z dnia 26.04.2017 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a83b082af14b9c0e7b20755","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,008 - 0,5) mg/m3"}],"technique":"Metoda spektrometrii w podczerwieni (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni (FT-IR)"],"computed":[],"activity":"Stężenie krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna\nZakres (0,008 - 0,5) mg/m3\nMetoda spektrometrii w podczerwieni (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna\nZakres (0,008 - 0,5) mg/m3\nMetoda spektrometrii w podczerwieni (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 Srodowisko pracy - powietrze Stezenie krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna\nZakres (0,008 - 0,5) mg/m3\nMetoda spektrometrii w podczerwieni (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, 4 (74), str. 117-130","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystalline silica (quartz, cristobalite) concentration – respirable fraction","parameters_en":[{"name":"Range","range":"(0,008 - 0,5) mg/m3"}],"search_en":"Workplace environment - air Crystalline silica (quartz, cristobalite) concentration – respirable fraction Infrared spectrometry (FT-IR) Range Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","technique_en":"Infrared spectrometry (FT-IR)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,008 - 0,5) mg/m3"}],"search_zh":"工作场所环境 — 空气 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b082af14b9c0e7b20756","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy – próbki powietrza pobierane na filtry","methodology":"Zawartość krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(5,0 - 400) μg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni (FT-IR)","techniques":["Metoda spektrometrii w podczerwieni (FT-IR)"],"computed":[],"activity":"Zawartość krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna\nZakres (5,0 - 400) μg w próbce\nMetoda spektrometrii w podczerwieni (FT-IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – próbki powietrza pobierane na filtry Zawartość krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna\nZakres (5,0 - 400) μg w próbce\nMetoda spektrometrii w podczerwieni (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 Srodowisko pracy – probki powietrza pobierane na filtry Zawartosc krystalicznej krzemionki (kwarcu, krystobalitu) – frakcja respirabilna\nZakres (5,0 - 400) μg w probce\nMetoda spektrometrii w podczerwieni (FT-IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, 4 (74), str. 117-130","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Crystalline silica content (quartz, cristobalite) – respirable fraction","parameters_en":[{"name":"Range","range":"(5,0 - 400) μg w próbce"}],"search_en":"Workplace environment – air samples collected on filters Crystalline silica content (quartz, cristobalite) – respirable fraction Infrared spectrometry (FT-IR) Range Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","technique_en":"Infrared spectrometry (FT-IR)","test_object_en":"Workplace environment – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(5,0 - 400) μg w próbce"}],"search_zh":"范围 Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"},{"_id":"6a83b082af14b9c0e7b20757","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 - 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 - 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 - 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 - 50) °C\nTemperatura wilgotna naturalna\nZakres (15 - 50) °C\nTemperatura poczernionej kuli\nZakres (15 - 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 - 50) °C\nTemperatura wilgotna naturalna\nZakres (15 - 50) °C\nTemperatura poczernionej kuli\nZakres (15 - 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 - 50) °C\nTemperatura wilgotna naturalna\nZakres (15 - 50) °C\nTemperatura poczernionej kuli\nZakres (15 - 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15 - 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15 - 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15 - 50) °C"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 - 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15 - 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(15 - 50) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b082af14b9c0e7b20758","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83b082af14b9c0e7b20759","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 - 35) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 - 85) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 35) °C\nWilgotność powietrza\nZakres (20 - 85) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 35) °C\nWilgotność powietrza\nZakres (20 - 85) %\nPrędkość powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 - 30) °C\nTemperatura poczernionej kuli\nZakres (10 - 35) °C\nWilgotnosc powietrza\nZakres (20 - 85) %\nPredkosc powietrza\nZakres (0,15 - 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 - 35) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 - 85) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 1,0) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 - 35) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 - 85) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b082af14b9c0e7b2075a","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83b082af14b9c0e7b2075b","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 - 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 - 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 2,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (20 - 90) %\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotność powietrza\nZakres (20 - 90) %\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 - 10) °C\nTemperatura poczernionej kuli\nZakres (-30 - 10) °C\nWilgotnosc powietrza\nZakres (20 - 90) %\nPredkosc powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 - 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 - 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 - 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 2,0) m/s"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 - 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 - 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 - 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 2,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83b082af14b9c0e7b2075c","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a83b082af14b9c0e7b2075d","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola elektrycznego w zakresie częstotliwości","parameters":[{"name":"10 Hz - 400 kHz"},{"name":"Zakres","range":"(20 V/m - 19 kV/m),"},{"name":"100 kHz - 40 MHz"},{"name":"Zakres","range":"(0,4 - 253) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w zakresie częstotliwości\nZakres:\n10 Hz - 400 kHz\nZakres (20 V/m - 19 kV/m),\n100 kHz - 40 MHz\nZakres (0,4 - 253) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola elektrycznego w zakresie częstotliwości\nZakres:\n10 Hz - 400 kHz\nZakres (20 V/m - 19 kV/m),\n100 kHz - 40 MHz\nZakres (0,4 - 253) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pole elektromagnetyczne Natezenie pola elektrycznego w zakresie czestotliwosci\nZakres:\n10 Hz - 400 kHz\nZakres (20 V/m - 19 kV/m),\n100 kHz - 40 MHz\nZakres (0,4 - 253) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wyl. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency range","parameters_en":[{"name":"10 Hz - 400 kHz"},{"name":"Range","range":"(20 V/m - 19 kV/m),"},{"name":"100 kHz - 40 MHz"},{"name":"Range","range":"(0,4 - 253) V/m"}],"search_en":"Workplace environment - electromagnetic field Electric field strength in the frequency range Direct measurement method 10 Hz - 400 kHz Range 100 kHz - 40 MHz Range PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"10 Hz - 400 kHz"},{"name":"范围","range":"(20 V/m - 19 kV/m),"},{"name":"100 kHz - 40 MHz"},{"name":"范围","range":"(0,4 - 253) V/m"}],"search_zh":"工作场所环境 — 电磁场 直接测量法 10 Hz - 400 kHz 范围 范围 PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a83b082af14b9c0e7b2075e","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Natężenie pola magnetycznego w zakresie częstotliwości","parameters":[{"name":"10 Hz - 400 kHz"},{"name":"Zakres","range":"(0,5 - 800) A/m,"},{"name":"300 kHz - 40 MHz"},{"name":"Zakres","range":"(0,010 - 16,0) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w zakresie częstotliwości\nZakres:\n10 Hz - 400 kHz\nZakres (0,5 - 800) A/m,\n300 kHz - 40 MHz\nZakres (0,010 - 16,0) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Natężenie pola magnetycznego w zakresie częstotliwości\nZakres:\n10 Hz - 400 kHz\nZakres (0,5 - 800) A/m,\n300 kHz - 40 MHz\nZakres (0,010 - 16,0) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pole elektromagnetyczne Natezenie pola magnetycznego w zakresie czestotliwosci\nZakres:\n10 Hz - 400 kHz\nZakres (0,5 - 800) A/m,\n300 kHz - 40 MHz\nZakres (0,010 - 16,0) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wyl. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency range","parameters_en":[{"name":"10 Hz - 400 kHz"},{"name":"Range","range":"(0,5 - 800) A/m,"},{"name":"300 kHz - 40 MHz"},{"name":"Range","range":"(0,010 - 16,0) A/m"}],"search_en":"Workplace environment - electromagnetic field Magnetic field strength in the frequency range Direct measurement method 10 Hz - 400 kHz Range 300 kHz - 40 MHz Range PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"10 Hz - 400 kHz"},{"name":"范围","range":"(0,5 - 800) A/m,"},{"name":"300 kHz - 40 MHz"},{"name":"范围","range":"(0,010 - 16,0) A/m"}],"search_zh":"工作场所环境 — 电磁场 下列频率范围内的磁场强度 直接测量法 10 Hz - 400 kHz 范围 范围 PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 电磁场","methodology_zh":"下列频率范围内的磁场强度"},{"_id":"6a83b082af14b9c0e7b2075f","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne","methodology":"Indukcja magnetyczna w zakresie częstotliwości 0 Hz:","parameters":[{"name":"Zakres","range":"(0,1 - 1000) mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości 0 Hz:\nZakres (0,1 - 1000) mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne Indukcja magnetyczna w zakresie częstotliwości 0 Hz:\nZakres (0,1 - 1000) mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pole elektromagnetyczne Indukcja magnetyczna w zakresie czestotliwosci 0 Hz:\nZakres (0,1 - 1000) mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wyl. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density in the frequency range 0 Hz:","parameters_en":[{"name":"Range","range":"(0,1 - 1000) mT"}],"search_en":"Workplace environment - electromagnetic field Magnetic flux density in the frequency range 0 Hz: Direct measurement method Range PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field","parameters_zh":[{"name":"范围","range":"(0,1 - 1000) mT"}],"search_zh":"工作场所环境 — 电磁场 直接测量法 范围 PN-T-06580-3:2002 z wył. pkt. 2.1.4.2 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 电磁场"},{"_id":"6a83b082af14b9c0e7b20760","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"w zakresie częstotliwości","range":"od 10 Hz do 1 kHz"},{"name":"Zakres","range":"(1 - 800) A/m"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Natężenie pola magnetycznego\nZakres:\nw zakresie częstotliwości od 10 Hz do 1 kHz\nZakres (1 - 800) A/m\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. tj. (Dz. U. 2018, poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Natężenie pola magnetycznego\nZakres:\nw zakresie częstotliwości od 10 Hz do 1 kHz\nZakres (1 - 800) A/m\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Natezenie pola magnetycznego\nZakres:\nw zakresie czestotliwosci od 10 Hz do 1 kHz\nZakres (1 - 800) A/m\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength","parameters_en":[{"name":"in the frequency range","range":"od 10 Hz do 1 kHz"},{"name":"Range","range":"(1 - 800) A/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic field strength Direct measurement method (simplified) in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","parameters_zh":[{"name":"频率范围","range":"od 10 Hz do 1 kHz"},{"name":"范围","range":"(1 - 800) A/m"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 磁场强度 直接测量法（简化） 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场","technique_zh":"直接测量法（简化）","methodology_zh":"磁场强度"},{"_id":"6a83b082af14b9c0e7b20761","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia UV w zakresie spektralnym (180 - 400) nm","parameters":[{"name":"Zakres","range":"(10-6 - 39,9) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda A)","techniques":["Metoda pomiarowa bezpośrednia (metoda A)"],"computed":[],"activity":"Skuteczne natężenie napromienienia UV w zakresie spektralnym (180 - 400) nm\nZakres (10-6 - 39,9) W/m2\nMetoda pomiarowa bezpośrednia (metoda A)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia UV w zakresie spektralnym (180 - 400) nm\nZakres (10-6 - 39,9) W/m2\nMetoda pomiarowa bezpośrednia (metoda A) PN-EN 14255-1:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia UV w zakresie spektralnym (180 - 400) nm\nZakres (10-6 - 39,9) W/m2\nMetoda pomiarowa bezposrednia (metoda A) PN-EN 14255-1:2010","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance UV in the spectral range (180 - 400) nm","parameters_en":[{"name":"Range","range":"(10-6 - 39,9) W/m2"}],"search_en":"Workplace environment - non-laser optical radiation Effective irradiance UV in the spectral range (180 - 400) nm Direct measurement method (method A) Range PN-EN 14255-1:2010","technique_en":"Direct measurement method (method A)","test_object_en":"Workplace environment - non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-6 - 39,9) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 A） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 A）"},{"_id":"6a83b082af14b9c0e7b20762","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczne napromienienie dla UV w zakresie spektralnym (180 - 400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczne napromienienie dla UV w zakresie spektralnym (180 - 400) nm (z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczne napromienienie dla UV w zakresie spektralnym (180 - 400) nm (z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczne napromienienie dla UV w zakresie spektralnym (180 - 400) nm (z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiant exposure for UV in the spectral range (180 - 400) nm (calculated)","search_en":"Workplace environment - non-laser optical radiation Effective radiant exposure for UV in the spectral range (180 - 400) nm (calculated) PN-EN 14255-1:2010","test_object_en":"Workplace environment - non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 (180 - 400) nm 光谱范围内 UV 的有效辐照量（由计算得出） PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","methodology_zh":"(180 - 400) nm 光谱范围内 UV 的有效辐照量（由计算得出）"},{"_id":"6a83b082af14b9c0e7b20763","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia dla UVA w zakresie spektralnym (315 - 400) nm","parameters":[{"name":"Zakres","range":"(10-3 - 3990) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda M)","techniques":["Metoda pomiarowa bezpośrednia (metoda M)"],"computed":[],"activity":"Natężenie napromienienia dla UVA w zakresie spektralnym (315 - 400) nm\nZakres (10-3 - 3990) W/m2\nMetoda pomiarowa bezpośrednia (metoda M)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Natężenie napromienienia dla UVA w zakresie spektralnym (315 - 400) nm\nZakres (10-3 - 3990) W/m2\nMetoda pomiarowa bezpośrednia (metoda M) PN-EN 14255-1:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Natezenie napromienienia dla UVA w zakresie spektralnym (315 - 400) nm\nZakres (10-3 - 3990) W/m2\nMetoda pomiarowa bezposrednia (metoda M) PN-EN 14255-1:2010","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance for UVA in the spectral range (315 - 400) nm","parameters_en":[{"name":"Range","range":"(10-3 - 3990) W/m2"}],"search_en":"Workplace environment - non-laser optical radiation Irradiance for UVA in the spectral range (315 - 400) nm Direct measurement method (method M) Range PN-EN 14255-1:2010","technique_en":"Direct measurement method (method M)","test_object_en":"Workplace environment - non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-3 - 3990) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 M） 范围 PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 M）"},{"_id":"6a83b082af14b9c0e7b20764","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Napromienienie dla UVA w zakresie spektralnym (315 - 400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie dla UVA w zakresie spektralnym (315 - 400) nm (z obliczeń)","reference":"PN-EN 14255-1:2010","norm_bases":["PN-EN 14255-1:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Napromienienie dla UVA w zakresie spektralnym (315 - 400) nm (z obliczeń) PN-EN 14255-1:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Napromienienie dla UVA w zakresie spektralnym (315 - 400) nm (z obliczen) PN-EN 14255-1:2010","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure for UVA in the spectral range (315 - 400) nm (calculated)","search_en":"Workplace environment - non-laser optical radiation Radiant exposure for UVA in the spectral range (315 - 400) nm (calculated) PN-EN 14255-1:2010","test_object_en":"Workplace environment - non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 (315 - 400) nm 光谱范围内 UVA 的辐照量（由计算得出） PN-EN 14255-1:2010","test_object_zh":"工作场所环境 — 非激光光辐射","methodology_zh":"(315 - 400) nm 光谱范围内 UVA 的辐照量（由计算得出）"},{"_id":"6a83b082af14b9c0e7b20765","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300 - 700) nm","parameters":[{"name":"Zakres","range":"(10-6 - 399) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda O)","techniques":["Metoda pomiarowa bezpośrednia (metoda O)"],"computed":[],"activity":"Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300 - 700) nm\nZakres (10-6 - 399) W/m2\nMetoda pomiarowa bezpośrednia (metoda O)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia VIS w zakresie spektralnym (300 - 700) nm\nZakres (10-6 - 399) W/m2\nMetoda pomiarowa bezpośrednia (metoda O) PN-EN 14255-2:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia VIS w zakresie spektralnym (300 - 700) nm\nZakres (10-6 - 399) W/m2\nMetoda pomiarowa bezposrednia (metoda O) PN-EN 14255-2:2010","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance VIS in the spectral range (300 - 700) nm","parameters_en":[{"name":"Range","range":"(10-6 - 399) W/m2"}],"search_en":"Workplace environment - non-laser optical radiation Effective irradiance VIS in the spectral range (300 - 700) nm Direct measurement method (method O) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method O)","test_object_en":"Workplace environment - non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-6 - 399) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 O） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 O）"},{"_id":"6a83b082af14b9c0e7b20766","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna VIS w zakresie spektralnym (300 - 700) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna VIS w zakresie spektralnym (300 - 700) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna VIS w zakresie spektralnym (300 - 700) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna VIS w zakresie spektralnym (300 - 700) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance VIS in the spectral range (300 - 700) nm (calculated)","search_en":"Workplace environment - non-laser optical radiation Effective radiance VIS in the spectral range (300 - 700) nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment - non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83b082af14b9c0e7b20767","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm","parameters":[{"name":"Zakres","range":"(30 - 3999) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda X)","techniques":["Metoda pomiarowa bezpośrednia (metoda X)"],"computed":[],"activity":"Natężenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm\nZakres (30 - 3999) W/m2\nMetoda pomiarowa bezpośrednia (metoda X)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Natężenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm\nZakres (30 - 3999) W/m2\nMetoda pomiarowa bezpośrednia (metoda X) PN-EN 14255-2:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Natezenie napromienienia VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm\nZakres (30 - 3999) W/m2\nMetoda pomiarowa bezposrednia (metoda X) PN-EN 14255-2:2010","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance of VIS, IRA and IRB in the spectral range (380 - 3000) nm","parameters_en":[{"name":"Range","range":"(30 - 3999) W/m2"}],"search_en":"Workplace environment - non-laser optical radiation Irradiance of VIS, IRA and IRB in the spectral range (380 - 3000) nm Direct measurement method (method X) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method X)","test_object_en":"Workplace environment - non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(30 - 3999) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 X） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 X）"},{"_id":"6a83b082af14b9c0e7b20768","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy - nielaserowe promieniowanie optyczne Napromienienie VIS, IRA i IRB w zakresie spektralnym (380 - 3000) nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure of VIS, IRA and IRB in the spectral range (380 - 3000) nm (calculated)","search_en":"Workplace environment - non-laser optical radiation Radiant exposure of VIS, IRA and IRB in the spectral range (380 - 3000) nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment - non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83b082af14b9c0e7b20769","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia VIS i IRA w zakresie spektralnym (380 - 1 400) nm","parameters":[{"name":"Zakres","range":"(10-6 - 3990) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia VIS i IRA w zakresie spektralnym (380 - 1 400) nm\nZakres (10-6 - 3990) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T 05687: 2002 pkt. 2.5.4","norm_bases":["PN-T 05687: 2002 pkt. 2.5.4"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia VIS i IRA w zakresie spektralnym (380 - 1 400) nm\nZakres (10-6 - 3990) W/m2\nMetoda pomiarowa bezpośrednia PN-T 05687: 2002 pkt. 2.5.4 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia VIS i IRA w zakresie spektralnym (380 - 1 400) nm\nZakres (10-6 - 3990) W/m2\nMetoda pomiarowa bezposrednia PN-T 05687: 2002 pkt. 2.5.4","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance VIS and IRA in the spectral range (380 - 1 400) nm","parameters_en":[{"name":"Range","range":"(10-6 - 3990) W/m2"}],"search_en":"Workplace environment - non-laser optical radiation Effective irradiance VIS and IRA in the spectral range (380 - 1 400) nm Direct measurement method Range PN-T 05687: 2002 pkt. 2.5.4","technique_en":"Direct measurement method","test_object_en":"Workplace environment - non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-6 - 3990) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法 范围 PN-T 05687: 2002 pkt. 2.5.4","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83b082af14b9c0e7b2076a","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna VIS i IRA w zakresie spektralnym (380 - 1 400) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna VIS i IRA w zakresie spektralnym (380 - 1 400) nm (z obliczeń)","reference":"PN-T 05687: 2002 pkt. 2.5.4","norm_bases":["PN-T 05687: 2002 pkt. 2.5.4"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna VIS i IRA w zakresie spektralnym (380 - 1 400) nm (z obliczeń) PN-T 05687: 2002 pkt. 2.5.4 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna VIS i IRA w zakresie spektralnym (380 - 1 400) nm (z obliczen) PN-T 05687: 2002 pkt. 2.5.4","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment - non-laser optical radiation PN-T 05687: 2002 pkt. 2.5.4","test_object_en":"Workplace environment - non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-T 05687: 2002 pkt. 2.5.4","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83b082af14b9c0e7b2076b","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 - 1 400) nm","parameters":[{"name":"Zakres","range":"(10-3 - 3990) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 - 1 400) nm\nZakres (10-3 - 3990) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T 05687: 2002 pkt. 2.5.4","norm_bases":["PN-T 05687: 2002 pkt. 2.5.4"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia IRA w zakresie spektralnym (780 - 1 400) nm\nZakres (10-3 - 3990) W/m2\nMetoda pomiarowa bezpośrednia PN-T 05687: 2002 pkt. 2.5.4 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia IRA w zakresie spektralnym (780 - 1 400) nm\nZakres (10-3 - 3990) W/m2\nMetoda pomiarowa bezposrednia PN-T 05687: 2002 pkt. 2.5.4","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance IRA in the spectral range (780 - 1 400) nm","parameters_en":[{"name":"Range","range":"(10-3 - 3990) W/m2"}],"search_en":"Workplace environment - non-laser optical radiation Effective irradiance IRA in the spectral range (780 - 1 400) nm Direct measurement method Range PN-T 05687: 2002 pkt. 2.5.4","technique_en":"Direct measurement method","test_object_en":"Workplace environment - non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-3 - 3990) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法 范围 PN-T 05687: 2002 pkt. 2.5.4","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83b082af14b9c0e7b2076c","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna IRA w zakresie spektralnym (1400 - 3000) nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna IRA w zakresie spektralnym (1400 - 3000) nm (z obliczeń)","reference":"PN-T 05687: 2002 pkt. 2.5.4","norm_bases":["PN-T 05687: 2002 pkt. 2.5.4"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna IRA w zakresie spektralnym (1400 - 3000) nm (z obliczeń) PN-T 05687: 2002 pkt. 2.5.4 Srodowisko pracy - nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna IRA w zakresie spektralnym (1400 - 3000) nm (z obliczen) PN-T 05687: 2002 pkt. 2.5.4","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance IRA in the spectral range (1400 - 3000) nm (calculated)","search_en":"Workplace environment - non-laser optical radiation Effective radiance IRA in the spectral range (1400 - 3000) nm (calculated) PN-T 05687: 2002 pkt. 2.5.4","test_object_en":"Workplace environment - non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-T 05687: 2002 pkt. 2.5.4","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83b082af14b9c0e7b2076d","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Czystość powietrza: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters":[{"name":"Zakres","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Zakres","range":"(35 - 349.999.965) cząstek/m3"}],"technique":"Metoda pomiaru - pomiar licznikiem cząstek","techniques":["Metoda pomiaru - pomiar licznikiem cząstek"],"computed":[],"activity":"Czystość powietrza: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nMetoda pomiaru - pomiar licznikiem cząstek","reference":"PN-EN ISO 14644-1:2016-03","norm_bases":["PN-EN ISO 14644-1:2016-03"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Czystość powietrza: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nMetoda pomiaru - pomiar licznikiem cząstek PN-EN ISO 14644-1:2016-03 Srodowisko pracy - powietrze Czystosc powietrza: Zawartosc liczbowa czastek o srednicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (1 - 9.999.999) czastek/ft3 lub\nZakres (35 - 349.999.965) czastek/m3\nMetoda pomiaru - pomiar licznikiem czastek PN-EN ISO 14644-1:2016-03","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air cleanliness: Particle number concentration for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters_en":[{"name":"Range","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Range","range":"(35 - 349.999.965) cząstek/m3"}],"search_en":"Workplace environment - air Air cleanliness: Particle number concentration for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Measurement method - measurement with a particle counter Range Range PN-EN ISO 14644-1:2016-03","technique_en":"Measurement method - measurement with a particle counter","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"范围","range":"(35 - 349.999.965) cząstek/m3"}],"search_zh":"工作场所环境 — 空气 范围 范围 PN-EN ISO 14644-1:2016-03","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b082af14b9c0e7b2076e","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Czas osiągnięcia czystości początkowej powietrza: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters":[{"name":"Zakres","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Zakres","range":"(35 - 349.999.965) cząstek/m3"}],"technique":"Metoda bezpośrednia - pomiar czasu (min); Metoda pomiaru - pomiar licznikiem cząstek","techniques":["Metoda bezpośrednia - pomiar czasu (min)","Metoda pomiaru - pomiar licznikiem cząstek"],"computed":[],"activity":"Czas osiągnięcia czystości początkowej powietrza: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nMetoda bezpośrednia - pomiar czasu (min); Metoda pomiaru - pomiar licznikiem cząstek","reference":"PN-EN ISO 14644-3:2020 pkt. 4.2.4 i załącznik B.4","norm_bases":["PN-EN ISO 14644-3:2020 pkt. 4.2.4 i załącznik B.4"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Czas osiągnięcia czystości początkowej powietrza: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nMetoda bezpośrednia - pomiar czasu (min); Metoda pomiaru - pomiar licznikiem cząstek PN-EN ISO 14644-3:2020 pkt. 4.2.4 i załącznik B.4 Srodowisko pracy - powietrze Czas osiagniecia czystosci poczatkowej powietrza: Zawartosc liczbowa czastek o srednicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (1 - 9.999.999) czastek/ft3 lub\nZakres (35 - 349.999.965) czastek/m3\nMetoda bezposrednia - pomiar czasu (min); Metoda pomiaru - pomiar licznikiem czastek PN-EN ISO 14644-3:2020 pkt. 4.2.4 i zalacznik B.4","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Recovery time to the initial air cleanliness: Particle number concentration for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters_en":[{"name":"Range","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Range","range":"(35 - 349.999.965) cząstek/m3"}],"search_en":"Workplace environment - air Recovery time to the initial air cleanliness: Particle number concentration for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Direct method - time measurement (min); Measurement method - measurement with a particle counter Range Range PN-EN ISO 14644-3:2020 pkt. 4.2.4 i załącznik B.4","technique_en":"Direct method - time measurement (min); Measurement method - measurement with a particle counter","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"范围","range":"(35 - 349.999.965) cząstek/m3"}],"search_zh":"工作场所环境 — 空气 范围 范围 PN-EN ISO 14644-3:2020 pkt. 4.2.4 i załącznik B.4","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b082af14b9c0e7b2076f","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Różnica ciśnień:","parameters":[{"name":"Zakres","range":"(-2500 - +2500) Pa"}],"technique":"Metoda pomiaru – pomiar różnicy ciśnień","techniques":["Metoda pomiaru – pomiar różnicy ciśnień"],"computed":[],"activity":"Różnica ciśnień:\nZakres (-2500 - +2500) Pa\nMetoda pomiaru – pomiar różnicy ciśnień","reference":"PN-EN ISO 14644-3:2020 pkt. 4.2.1 i załącznik B.1","norm_bases":["PN-EN ISO 14644-3:2020 pkt. 4.2.1 i załącznik B.1"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Różnica ciśnień:\nZakres (-2500 - +2500) Pa\nMetoda pomiaru – pomiar różnicy ciśnień PN-EN ISO 14644-3:2020 pkt. 4.2.1 i załącznik B.1 Srodowisko pracy - powietrze Roznica cisnien:\nZakres (-2500 - +2500) Pa\nMetoda pomiaru – pomiar roznicy cisnien PN-EN ISO 14644-3:2020 pkt. 4.2.1 i zalacznik B.1","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pressure difference:","parameters_en":[{"name":"Range","range":"(-2500 - +2500) Pa"}],"search_en":"Workplace environment - air Pressure difference: Measurement method – pressure difference measurement Range PN-EN ISO 14644-3:2020 pkt. 4.2.1 i załącznik B.1","technique_en":"Measurement method – pressure difference measurement","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(-2500 - +2500) Pa"}],"search_zh":"工作场所环境 — 空气 范围 PN-EN ISO 14644-3:2020 pkt. 4.2.1 i załącznik B.1","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83b082af14b9c0e7b20770","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(-40 - +70) °C"}],"technique":"Metoda pomiarowa – pomiar temperatury","techniques":["Metoda pomiarowa – pomiar temperatury"],"computed":[],"activity":"Temperatura\nZakres (-40 - +70) °C\nMetoda pomiarowa – pomiar temperatury","reference":"PN-EN ISO 14644-3:2020 pkt. 4.2.5 i załącznik B.5","norm_bases":["PN-EN ISO 14644-3:2020 pkt. 4.2.5 i załącznik B.5"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Temperatura\nZakres (-40 - +70) °C\nMetoda pomiarowa – pomiar temperatury PN-EN ISO 14644-3:2020 pkt. 4.2.5 i załącznik B.5 Srodowisko pracy - powietrze Temperatura\nZakres (-40 - +70) °C\nMetoda pomiarowa – pomiar temperatury PN-EN ISO 14644-3:2020 pkt. 4.2.5 i zalacznik B.5","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(-40 - +70) °C"}],"search_en":"Workplace environment - air Temperature Measurement method – temperature measurement Range PN-EN ISO 14644-3:2020 pkt. 4.2.5 i załącznik B.5","technique_en":"Measurement method – temperature measurement","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(-40 - +70) °C"}],"search_zh":"工作场所环境 — 空气 温度 范围 PN-EN ISO 14644-3:2020 pkt. 4.2.5 i załącznik B.5","test_object_zh":"工作场所环境 — 空气","methodology_zh":"温度"},{"_id":"6a83b082af14b9c0e7b20771","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wilgotność względna","parameters":[{"name":"Zakres","range":"(0 - 90) %"}],"technique":"Metoda pomiaru – pomiar wilgotności","techniques":["Metoda pomiaru – pomiar wilgotności"],"computed":[],"activity":"Wilgotność względna\nZakres (0 - 90) %\nMetoda pomiaru – pomiar wilgotności","reference":"PN-EN ISO 14644-3:2020 pkt. 4.2.6 i załącznik B.6","norm_bases":["PN-EN ISO 14644-3:2020 pkt. 4.2.6 i załącznik B.6"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wilgotność względna\nZakres (0 - 90) %\nMetoda pomiaru – pomiar wilgotności PN-EN ISO 14644-3:2020 pkt. 4.2.6 i załącznik B.6 Srodowisko pracy - powietrze Wilgotnosc wzgledna\nZakres (0 - 90) %\nMetoda pomiaru – pomiar wilgotnosci PN-EN ISO 14644-3:2020 pkt. 4.2.6 i zalacznik B.6","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Relative humidity","parameters_en":[{"name":"Range","range":"(0 - 90) %"}],"search_en":"Workplace environment - air Relative humidity Measurement method – humidity measurement Range PN-EN ISO 14644-3:2020 pkt. 4.2.6 i załącznik B.6","technique_en":"Measurement method – humidity measurement","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0 - 90) %"}],"search_zh":"工作场所环境 — 空气 相对湿度 范围 PN-EN ISO 14644-3:2020 pkt. 4.2.6 i załącznik B.6","test_object_zh":"工作场所环境 — 空气","methodology_zh":"相对湿度"},{"_id":"6a83b082af14b9c0e7b20772","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Pomieszczenia czyste i komory laminarne","methodology":"Przenikalność Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters":[{"name":"Zakres","range":"(diluter 1:100):"},{"name":"Zakres","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Zakres","range":"(35 - 349.999.965) cząstek/m3"},{"name":"stężenie masowe cząstek"},{"name":"Zakres","range":"(0,0003 - 100) g/l"}],"technique":"Metoda pomiaru- pomiar licznikiem cząstek; Metoda pomiaru - pomiar fotometrem liniowym","techniques":["Metoda pomiaru- pomiar licznikiem cząstek","Metoda pomiaru - pomiar fotometrem liniowym"],"computed":[],"activity":"Przenikalność Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100):\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nstężenie masowe cząstek\nZakres (0,0003 - 100) g/l\nMetoda pomiaru- pomiar licznikiem cząstek; Metoda pomiaru - pomiar fotometrem liniowym","reference":"PN-EN ISO 14644-3:2020 pkt. 4.2.8 i załącznik B.8","norm_bases":["PN-EN ISO 14644-3:2020 pkt. 4.2.8 i załącznik B.8"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia czyste i komory laminarne Przenikalność Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100):\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nstężenie masowe cząstek\nZakres (0,0003 - 100) g/l\nMetoda pomiaru- pomiar licznikiem cząstek; Metoda pomiaru - pomiar fotometrem liniowym PN-EN ISO 14644-3:2020 pkt. 4.2.8 i załącznik B.8 Pomieszczenia czyste i komory laminarne Przenikalnosc Zawartosc liczbowa czastek o srednicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100):\nZakres (1 - 9.999.999) czastek/ft3 lub\nZakres (35 - 349.999.965) czastek/m3\nstezenie masowe czastek\nZakres (0,0003 - 100) g/l\nMetoda pomiaru- pomiar licznikiem czastek; Metoda pomiaru - pomiar fotometrem liniowym PN-EN ISO 14644-3:2020 pkt. 4.2.8 i zalacznik B.8","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Penetration Number content of particles with diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters_en":[{"name":"Range","range":"(diluter 1:100):"},{"name":"Range","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Range","range":"(35 - 349.999.965) cząstek/m3"},{"name":"particle mass concentration"},{"name":"Range","range":"(0,0003 - 100) g/l"}],"search_en":"Cleanrooms and laminar flow cabinets Penetration Number content of particles with diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Range Range Range particle mass concentration Range PN-EN ISO 14644-3:2020 pkt. 4.2.8 i załącznik B.8","test_object_en":"Cleanrooms and laminar flow cabinets","parameters_zh":[{"name":"范围","range":"(diluter 1:100):"},{"name":"范围","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"范围","range":"(35 - 349.999.965) cząstek/m3"},{"name":"stężenie masowe cząstek"},{"name":"范围","range":"(0,0003 - 100) g/l"}],"search_zh":"范围 范围 范围 范围 PN-EN ISO 14644-3:2020 pkt. 4.2.8 i załącznik B.8"},{"_id":"6a83b082af14b9c0e7b20773","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Filtr powietrza","methodology":"Integralność oraz szczelność mocowania filtra: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters":[{"name":"Zakres","range":"(diluter 1:100):"},{"name":"Zakres","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Zakres","range":"(35 - 349.999.965) cząstek/m3"},{"name":"Stężenie masowe cząstek"},{"name":"Zakres","range":"(0,0003 - 100) g/l"}],"technique":"Metoda pomiaru - pomiar licznikiem cząstek; Metoda pomiaru - pomiar fotometrem liniowym","techniques":["Metoda pomiaru - pomiar licznikiem cząstek","Metoda pomiaru - pomiar fotometrem liniowym"],"computed":[],"activity":"Integralność oraz szczelność mocowania filtra: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100):\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nStężenie masowe cząstek\nZakres (0,0003 - 100) g/l\nMetoda pomiaru - pomiar licznikiem cząstek; Metoda pomiaru - pomiar fotometrem liniowym","reference":"PN-EN ISO 14644-3:2020 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6","norm_bases":["PN-EN ISO 14644-3:2020 pkt. 4.2.7 i załącznik B.7","PN-EN 1822-1:2019-05 pkt. 5 i 6"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Filtr powietrza Integralność oraz szczelność mocowania filtra: Zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100):\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nStężenie masowe cząstek\nZakres (0,0003 - 100) g/l\nMetoda pomiaru - pomiar licznikiem cząstek; Metoda pomiaru - pomiar fotometrem liniowym PN-EN ISO 14644-3:2020 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6 Filtr powietrza Integralnosc oraz szczelnosc mocowania filtra: Zawartosc liczbowa czastek o srednicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100):\nZakres (1 - 9.999.999) czastek/ft3 lub\nZakres (35 - 349.999.965) czastek/m3\nStezenie masowe czastek\nZakres (0,0003 - 100) g/l\nMetoda pomiaru - pomiar licznikiem czastek; Metoda pomiaru - pomiar fotometrem liniowym PN-EN ISO 14644-3:2020 pkt. 4.2.7 i zalacznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6","categories":["other"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Integrity and tightness of the filter mounting: Particle number content for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters_en":[{"name":"Range","range":"(diluter 1:100):"},{"name":"Range","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Range","range":"(35 - 349.999.965) cząstek/m3"},{"name":"Particle mass concentration"},{"name":"Range","range":"(0,0003 - 100) g/l"}],"search_en":"Air filter Integrity and tightness of the filter mounting: Particle number content for diameters: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm Measurement method - measurement with a particle counter; Measurement method - measurement with a linear photometer Range Range Range Particle mass concentration Range PN-EN ISO 14644-3:2020 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6","technique_en":"Measurement method - measurement with a particle counter; Measurement method - measurement with a linear photometer","test_object_en":"Air filter","parameters_zh":[{"name":"范围","range":"(diluter 1:100):"},{"name":"范围","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"范围","range":"(35 - 349.999.965) cząstek/m3"},{"name":"Stężenie masowe cząstek"},{"name":"范围","range":"(0,0003 - 100) g/l"}],"search_zh":"范围 范围 范围 范围 PN-EN ISO 14644-3:2020 pkt. 4.2.7 i załącznik B.7 | PN-EN 1822-1:2019-05 pkt. 5 i 6"},{"_id":"6a83b082af14b9c0e7b20774","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Sprężone powietrze","methodology":"Czystość: - zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm","parameters":[{"name":"Zakres","range":"(diluter 1:100)"},{"name":"Zakres","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Zakres","range":"(35 - 349.999.965) cząstek/m3"}],"technique":"Metoda pomiaru - pomiar licznikiem cząstek","techniques":["Metoda pomiaru - pomiar licznikiem cząstek"],"computed":[],"activity":"Czystość: - zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100)\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nMetoda pomiaru - pomiar licznikiem cząstek","reference":"EB3b-001 wydanie VII z dnia 18.07.2022 r.","norm_bases":["EB3b-001 wydanie VII z dnia 18.07.2022 r."],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sprężone powietrze Czystość: - zawartość liczbowa cząstek o średnicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100)\nZakres (1 - 9.999.999) cząstek/ft3 lub\nZakres (35 - 349.999.965) cząstek/m3\nMetoda pomiaru - pomiar licznikiem cząstek EB3b-001 wydanie VII z dnia 18.07.2022 r. Sprezone powietrze Czystosc: - zawartosc liczbowa czastek o srednicach: (0,1; 0,3; 0,5; 1,0; 3,0; 5,0) μm\nZakres:\nZakres (diluter 1:100)\nZakres (1 - 9.999.999) czastek/ft3 lub\nZakres (35 - 349.999.965) czastek/m3\nMetoda pomiaru - pomiar licznikiem czastek EB3b-001 wydanie VII z dnia 18.07.2022 r.","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(diluter 1:100)"},{"name":"Range","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"Range","range":"(35 - 349.999.965) cząstek/m3"}],"search_en":"Compressed air Measurement method - measurement with a particle counter Range Range Range EB3b-001 wydanie VII z dnia 18.07.2022 r.","technique_en":"Measurement method - measurement with a particle counter","test_object_en":"Compressed air","parameters_zh":[{"name":"范围","range":"(diluter 1:100)"},{"name":"范围","range":"(1 - 9.999.999) cząstek/ft3 lub"},{"name":"范围","range":"(35 - 349.999.965) cząstek/m3"}],"search_zh":"范围 范围 范围 EB3b-001 wydanie VII z dnia 18.07.2022 r."},{"_id":"6a83b082af14b9c0e7b20775","lab_id":"69ad52a3de79e566650fb3c6","country":"PL","accr_number":"AB 752","accr_body":"PCA","test_object":"Wentylacja","methodology":"Prędkość powietrza:","parameters":[{"name":"Zakres","range":"(0,2 - 40) m/s"},{"name":"Strumień objętości powietrza:"},{"name":"Zakres","range":"(50 - 2000) m3/godz."}],"technique":"Metoda pomiaru - pośrednia i bezpośrednia","techniques":["Metoda pomiaru - pośrednia i bezpośrednia"],"computed":[],"activity":"Prędkość powietrza:\nZakres:\nZakres (0,2 - 40) m/s\nStrumień objętości powietrza:\nZakres (50 - 2000) m3/godz.\nMetoda pomiaru - pośrednia i bezpośrednia","reference":"PN-EN ISO 14644-3:2020 pkt. 4.2.2 i załącznik B.2","norm_bases":["PN-EN ISO 14644-3:2020 pkt. 4.2.2 i załącznik B.2"],"lab_section":"Paweł Lisowski Eksperckie Biuro Zarządzania Bezpieczeństwem Pracy Sekcja Badań Pomieszczeń Czystych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wentylacja Prędkość powietrza:\nZakres:\nZakres (0,2 - 40) m/s\nStrumień objętości powietrza:\nZakres (50 - 2000) m3/godz.\nMetoda pomiaru - pośrednia i bezpośrednia PN-EN ISO 14644-3:2020 pkt. 4.2.2 i załącznik B.2 Wentylacja Predkosc powietrza:\nZakres:\nZakres (0,2 - 40) m/s\nStrumien objetosci powietrza:\nZakres (50 - 2000) m3/godz.\nMetoda pomiaru - posrednia i bezposrednia PN-EN ISO 14644-3:2020 pkt. 4.2.2 i zalacznik B.2","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air velocity:","parameters_en":[{"name":"Range","range":"(0,2 - 40) m/s"},{"name":"Air volume flow rate:"},{"name":"Range","range":"(50 - 2000) m3/godz."}],"search_en":"Ventilation Air velocity: Measurement method - indirect and direct Range Air volume flow rate: Range PN-EN ISO 14644-3:2020 pkt. 4.2.2 i załącznik B.2","technique_en":"Measurement method - indirect and direct","test_object_en":"Ventilation","parameters_zh":[{"name":"范围","range":"(0,2 - 40) m/s"},{"name":"Strumień objętości powietrza:"},{"name":"范围","range":"(50 - 2000) m3/godz."}],"search_zh":"范围 范围 PN-EN ISO 14644-3:2020 pkt. 4.2.2 i załącznik B.2"}],"has_pdf":true}