{"lab":{"_id":"69ad52a3de79e566650fb3be","accr_number":"AB 746","country":"PL","accr_body":"PCA","address":"ul. Dworcowa 47, 44-190 Knurów","categories":["environment","materials"],"city":"Knurów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":290,"name":"Eurofins SEPO Sp. z o. o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_746.pdf"],"scope_summary":"","search_text":"eurofins sepo sp. z o. o. ul. dworcowa 47, 44-190 knurów environment materials other construction electronics food automotive petro metrology pharma","status":"active","updated_at":"2026-03-08T14:51:38.311Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T00:59:33.923Z","email_confidence":"high","email_mx":true,"email_source":"https://www.sepo.pl/kontakt/","fields_of_testing":[{"codes":"A/13","pl":"Badania akustyczne i drgań – maszyny i urządzenia","en":"Acoustic and vibration tests - machinery and devices"},{"codes":"A/5","pl":"Badania akustyczne obiektów budowlanych","en":"Acoustic tests – building products, materials and items"},{"codes":"C/9/P, C/33/P, C/36/P","pl":"Badania chemiczne i pobieranie próbek - środowisko pracy (czynniki szkodliwe - powietrze), powietrze, gazy odlotowe","en":"Chemical tests and sampling - working environment (harmful factors - air), air, waste gases, landfill gases,"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, wydatek energetyczny, pola elektromagnetyczne, mikroklimat, nielaserowe promieniowanie optyczne)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors noise, lighting, vibration, energy expenditure, electromagnetic field, microclimate, non-laser optical radiation)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors - noise)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) – waste gases"},{"codes":"G/35","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – pomieszczenia (warunki środowiskowe – wentylacja)","en":"Tests concerning environmental engineering (environmental and climatic) – facilities (environmental conditions - ventilation)"}],"issue":{"no":"38","date":"22.07.2026"},"parse_date":"2026-08-18T00:59:33.923Z","parse_source":"agent-claude-code","map_coord":[50.219024,18.699195],"map_geo":"nominatim-street","lab_locations":[{"name":"Dział Pomiarowo-Analityczny","address":"ul. Dworcowa 47, 44-190 Knurów","city":"Knurów","postal":"44-190"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/1f4587d511cc0739c8af0861d2a88b9b/AB%20746.pdf","has_en":true,"category_counts":{"environment":189,"other":96,"materials":5,"construction":2,"metrology":2,"petro":2,"automotive":1},"category_scores":{"environment":120.27,"other":31.03,"materials":0.08,"construction":0.01,"metrology":0.01,"petro":0.01,"automotive":0},"has_zh":true},"methods":[{"_id":"6a83ae76af14b9c0e7b20383","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method dust agents inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 粉尘因素 可吸入组分 呼吸性组分 有机物质，包括 可吸入组分 无机物质，包括 可吸入组分 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","technique_zh":"个体剂量测定法；定点测定法","methodology_zh":"职业接触评估采样，针对："},{"_id":"6a83ae76af14b9c0e7b20384","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek w celu oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja torakalna"},{"name":"azbest – włókna respirabilne"},{"name":"sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"},{"name":"węglik krzemu włóknisty – włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja torakalna\nazbest – włókna respirabilne\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek w celu oceny narażenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja torakalna\nazbest – włókna respirabilne\nsztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu włóknisty – włókna respirabilne\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek w celu oceny narazenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja torakalna\nazbest – wlokna respirabilne\nsztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nweglik krzemu wloknisty – wlokna respirabilne\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances, including"},{"name":"thoracic fraction"},{"name":"asbestos – respirable fibres"},{"name":"man-made mineral fibres excluding refractory ceramic fibres – respirable fibres"},{"name":"silicon carbide fibrous – respirable fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method inorganic substances, including thoracic fraction asbestos – respirable fibres man-made mineral fibres excluding refractory ceramic fibres – respirable fibres silicon carbide fibrous – respirable fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 无机物质，包括 胸腔组分 石棉 — 呼吸性纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 纤维状碳化硅 － 呼吸性纤维 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"无机物质，包括"},{"name":"胸腔组分"},{"name":"石棉 — 呼吸性纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"},{"name":"纤维状碳化硅 － 呼吸性纤维"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}],"methodology_zh":"职业接触评估采样，针对："},{"_id":"6a83ae76af14b9c0e7b20385","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83ae76af14b9c0e7b20386","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Węglik krzemu, włóknisty"},{"name":"Sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"Zakres","range":"(0,05 – 20,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nWęglik krzemu, włóknisty\nSztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nZakres (0,05 – 20,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nWęglik krzemu, włóknisty\nSztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nZakres (0,05 – 20,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nWeglik krzemu, wloknisty\nSztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych\nZakres (0,05 – 20,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Silicon carbide, fibrous"},{"name":"Man-made mineral fibres excluding refractory ceramic fibres"},{"name":"Range","range":"(0,05 – 20,0) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Silicon carbide, fibrous Man-made mineral fibres excluding refractory ceramic fibres Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"碳化硅，纤维状"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"范围","range":"(0,05 – 20,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 碳化硅，纤维状 人造矿物纤维，耐火陶瓷纤维除外 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a83ae76af14b9c0e7b20387","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Spaliny silnika Diesla"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,05 – 7,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSpaliny silnika Diesla\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,05 – 7,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSpaliny silnika Diesla\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,05 – 7,0) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSpaliny silnika Diesla\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,05 – 7,0) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Diesel engine exhaust"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,05 – 7,0) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Diesel engine exhaust Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"柴油机排气"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,05 – 7,0) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘： 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 柴油机排气 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘："},{"_id":"6a83ae76af14b9c0e7b20388","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłu pobranego pyłomierzem CIP-10 – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,11 – 69) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu pobranego pyłomierzem CIP-10 – frakcja wdychalna\nZakres (0,11 – 69) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05","norm_bases":["PN-Z-04507:2022-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłu pobranego pyłomierzem CIP-10 – frakcja wdychalna\nZakres (0,11 – 69) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 Srodowisko pracy – powietrze Stezenie pylu pobranego pylomierzem CIP-10 – frakcja wdychalna\nZakres (0,11 – 69) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of dust collected with a CIP-10 dust sampler – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,11 – 69) mg/m3"}],"search_en":"Workplace environment – air Concentration of dust collected with a CIP-10 dust sampler – inhalable fraction Gravimetric method Range PN-Z-04507:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,11 – 69) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 范围 PN-Z-04507:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83ae76af14b9c0e7b20389","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłu pobranego pyłomierzem CIP-10 – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,11 – 69) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu pobranego pyłomierzem CIP-10 – frakcja respirabilna\nZakres (0,11 – 69) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05","norm_bases":["PN-Z-04508:2022-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłu pobranego pyłomierzem CIP-10 – frakcja respirabilna\nZakres (0,11 – 69) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 Srodowisko pracy – powietrze Stezenie pylu pobranego pylomierzem CIP-10 – frakcja respirabilna\nZakres (0,11 – 69) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of dust collected with a CIP-10 dust sampler – respirable fraction","parameters_en":[{"name":"Range","range":"(0,11 – 69) mg/m3"}],"search_en":"Workplace environment – air Concentration of dust collected with a CIP-10 dust sampler – respirable fraction Gravimetric method Range PN-Z-04508:2022-05","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(0,11 – 69) mg/m3"}],"search_zh":"工作场所环境 — 空气 重量法 范围 PN-Z-04508:2022-05","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83ae76af14b9c0e7b2038a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie olejów mineralnych wysokorafinowanych – z wyłączeniem cieczy obróbkowych – frakcja wdychalna","parameters":[],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie olejów mineralnych wysokorafinowanych – z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04108-5:2006","norm_bases":["PN-Z-04108-5:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie olejów mineralnych wysokorafinowanych – z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04108-5:2006 Srodowisko pracy – powietrze Pobieranie olejow mineralnych wysokorafinowanych – z wylaczeniem cieczy obrobkowych – frakcja wdychalna\nMetoda dozymetrii indywidualnej PN-Z-04108-5:2006","categories":["environment","petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling of highly refined mineral oils – excluding metalworking fluids – inhalable fraction","search_en":"Workplace environment – air Sampling of highly refined mineral oils – excluding metalworking fluids – inhalable fraction Personal dosimetry method PN-Z-04108-5:2006","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 个体剂量测定法 PN-Z-04108-5:2006","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83ae76af14b9c0e7b2038b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04108-5:2006","norm_bases":["PN-Z-04108-5:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04108-5:2006 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04108-5:2006","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) PN-Z-04108-5:2006","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04108-5:2006","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a83ae76af14b9c0e7b2038c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"CO","range":"(3,5 - 234) mg/m3"},{"name":"Zakres","range":"(3,0 - 201) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nCO (3,5 - 234) mg/m3\nZakres (3,0 - 201) ppm\nMetoda elektrochemiczna","reference":"PB-07/W7-10.09.2021","norm_bases":["PB-07/W7-10.09.2021"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tlenku węgla\nZakres:\nCO (3,5 - 234) mg/m3\nZakres (3,0 - 201) ppm\nMetoda elektrochemiczna PB-07/W7-10.09.2021 Srodowisko pracy – powietrze Stezenie tlenku wegla\nZakres:\nCO (3,5 - 234) mg/m3\nZakres (3,0 - 201) ppm\nMetoda elektrochemiczna PB-07/W7-10.09.2021","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"CO","range":"(3,5 - 234) mg/m3"},{"name":"Range","range":"(3,0 - 201) ppm"}],"search_en":"Workplace environment – air Carbon monoxide concentration Electrochemical method CO Range PB-07/W7-10.09.2021","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"CO","range":"(3,5 - 234) mg/m3"},{"name":"范围","range":"(3,0 - 201) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 CO 范围 PB-07/W7-10.09.2021","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a83ae76af14b9c0e7b2038d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie ditlenku węgla","parameters":[{"name":"CO2","range":"(732 – 55836) mg/m3"}],"technique":"Metoda spektrometrii w zakresie podczerwieni","techniques":["Metoda spektrometrii w zakresie podczerwieni"],"computed":[],"activity":"Stężenie ditlenku węgla\nCO2 (732 – 55836) mg/m3\nMetoda spektrometrii w zakresie podczerwieni","reference":"PB-07/W7-10.09.2021","norm_bases":["PB-07/W7-10.09.2021"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie ditlenku węgla\nCO2 (732 – 55836) mg/m3\nMetoda spektrometrii w zakresie podczerwieni PB-07/W7-10.09.2021 Srodowisko pracy – powietrze Stezenie ditlenku wegla\nCO2 (732 – 55836) mg/m3\nMetoda spektrometrii w zakresie podczerwieni PB-07/W7-10.09.2021","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"CO2","range":"(732 – 55836) mg/m3"}],"search_en":"Workplace environment – air Carbon dioxide concentration Infrared spectrometry method CO2 PB-07/W7-10.09.2021","technique_en":"Infrared spectrometry method","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 二氧化碳浓度 红外光谱法 CO2 PB-07/W7-10.09.2021","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"CO2","range":"(732 – 55836) mg/m3"}],"methodology_zh":"二氧化碳浓度","technique_zh":"红外光谱法"},{"_id":"6a83ae76af14b9c0e7b2038e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-07/W7-10.09.2021","norm_bases":["PB-07/W7-10.09.2021"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźniki narażenia (z obliczeń) PB-07/W7-10.09.2021 Srodowisko pracy – powietrze Wskazniki narazenia (z obliczen) PB-07/W7-10.09.2021","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment – air Exposure indices (calculated) PB-07/W7-10.09.2021","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-07/W7-10.09.2021","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a83ae76af14b9c0e7b2038f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość tlenku azotu, ditlenku azotu","parameters":[{"name":"NO","range":"(0,144 – 22,2) mg/m3"},{"name":"Zakres","range":"(0,115 – 17,8) ppm"},{"name":"Zakres","range":"(0,00065 – 0,100) mg w próbce"},{"name":"NO2","range":"(0,044 – 4,44) mg/m3"},{"name":"NO2","range":"(0,023 – 2,32) ppm"},{"name":"NO2","range":"(0,00020 – 0,020) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość tlenku azotu, ditlenku azotu\nZakres:\nNO (0,144 – 22,2) mg/m3\nZakres (0,115 – 17,8) ppm\nZakres (0,00065 – 0,100) mg w próbce\nNO2 (0,044 – 4,44) mg/m3\nNO2 (0,023 – 2,32) ppm\nNO2 (0,00020 – 0,020) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość tlenku azotu, ditlenku azotu\nZakres:\nNO (0,144 – 22,2) mg/m3\nZakres (0,115 – 17,8) ppm\nZakres (0,00065 – 0,100) mg w próbce\nNO2 (0,044 – 4,44) mg/m3\nNO2 (0,023 – 2,32) ppm\nNO2 (0,00020 – 0,020) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc tlenku azotu, ditlenku azotu\nZakres:\nNO (0,144 – 22,2) mg/m3\nZakres (0,115 – 17,8) ppm\nZakres (0,00065 – 0,100) mg w probce\nNO2 (0,044 – 4,44) mg/m3\nNO2 (0,023 – 2,32) ppm\nNO2 (0,00020 – 0,020) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of nitrogen monoxide, nitrogen dioxide","parameters_en":[{"name":"NO","range":"(0,144 – 22,2) mg/m3"},{"name":"Range","range":"(0,115 – 17,8) ppm"},{"name":"Range","range":"(0,00065 – 0,100) mg w próbce"},{"name":"NO2","range":"(0,044 – 4,44) mg/m3"},{"name":"NO2","range":"(0,023 – 2,32) ppm"},{"name":"NO2","range":"(0,00020 – 0,020) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of nitrogen monoxide, nitrogen dioxide Spectrophotometric method NO Range Range NO2 NO2 NO2 PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"NO","range":"(0,144 – 22,2) mg/m3"},{"name":"范围","range":"(0,115 – 17,8) ppm"},{"name":"范围","range":"(0,00065 – 0,100) mg w próbce"},{"name":"NO2","range":"(0,044 – 4,44) mg/m3"},{"name":"NO2","range":"(0,023 – 2,32) ppm"},{"name":"NO2","range":"(0,00020 – 0,020) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 NO 范围 范围 NO2 NO2 NO2 PN-Z-04009-11:2008","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83ae76af14b9c0e7b20390","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość ditlenku siarki","parameters":[{"name":"Zakres","range":"(0,10 – 6,40) mg/m3"},{"name":"Zakres","range":"(0,038 – 2,40) ppm"},{"name":"Zakres","range":"(0,0010 – 0,0640) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość ditlenku siarki\nZakres:\nZakres (0,10 – 6,40) mg/m3\nZakres (0,038 – 2,40) ppm\nZakres (0,0010 – 0,0640) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996+Ap1:2001","norm_bases":["PN-Z-04015-12:1996+Ap1:2001"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość ditlenku siarki\nZakres:\nZakres (0,10 – 6,40) mg/m3\nZakres (0,038 – 2,40) ppm\nZakres (0,0010 – 0,0640) mg w próbce\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc ditlenku siarki\nZakres:\nZakres (0,10 – 6,40) mg/m3\nZakres (0,038 – 2,40) ppm\nZakres (0,0010 – 0,0640) mg w probce\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulphur dioxide","parameters_en":[{"name":"Range","range":"(0,10 – 6,40) mg/m3"},{"name":"Range","range":"(0,038 – 2,40) ppm"},{"name":"Range","range":"(0,0010 – 0,0640) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of sulphur dioxide Spectrophotometric method Range Range Range PN-Z-04015-12:1996+Ap1:2001","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,10 – 6,40) mg/m3"},{"name":"范围","range":"(0,038 – 2,40) ppm"},{"name":"范围","range":"(0,0010 – 0,0640) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 二氧化硫的浓度/含量 分光光度法 范围 范围 范围 PN-Z-04015-12:1996+Ap1:2001","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"二氧化硫的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20391","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość kwasu azotowego (V)","parameters":[{"name":"Zakres","range":"(0,28 – 2,44) mg/m3"},{"name":"Zakres","range":"(0,000274 – 0,0274) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość kwasu azotowego (V)\nZakres:\nZakres (0,28 – 2,44) mg/m3\nZakres (0,000274 – 0,0274) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04009-11:2008","PN-Z-04073-1:2014-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość kwasu azotowego (V)\nZakres:\nZakres (0,28 – 2,44) mg/m3\nZakres (0,000274 – 0,0274) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc kwasu azotowego (V)\nZakres:\nZakres (0,28 – 2,44) mg/m3\nZakres (0,000274 – 0,0274) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of nitric (V) acid","parameters_en":[{"name":"Range","range":"(0,28 – 2,44) mg/m3"},{"name":"Range","range":"(0,000274 – 0,0274) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of nitric (V) acid Spectrophotometric method Range Range PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,28 – 2,44) mg/m3"},{"name":"范围","range":"(0,000274 – 0,0274) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 范围 范围 PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83ae76af14b9c0e7b20392","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość dekatlenku tetrafosforu","parameters":[{"name":"Zakres","range":"(0,10 – 2,86) mg/m3"},{"name":"Zakres","range":"(0,00070 – 0,020) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość dekatlenku tetrafosforu\nZakres:\nZakres (0,10 – 2,86) mg/m3\nZakres (0,00070 – 0,020) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04009-11:2008","PN-Z-04073-1:2014-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość dekatlenku tetrafosforu\nZakres:\nZakres (0,10 – 2,86) mg/m3\nZakres (0,00070 – 0,020) mg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc dekatlenku tetrafosforu\nZakres:\nZakres (0,10 – 2,86) mg/m3\nZakres (0,00070 – 0,020) mg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of tetraphosphorus decaoxide","parameters_en":[{"name":"Range","range":"(0,10 – 2,86) mg/m3"},{"name":"Range","range":"(0,00070 – 0,020) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of tetraphosphorus decaoxide Spectrophotometric method Range Range PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,10 – 2,86) mg/m3"},{"name":"范围","range":"(0,00070 – 0,020) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 范围 范围 PN-Z-04009-11:2008 | PN-Z-04073-1:2014-08","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83ae76af14b9c0e7b20393","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość kwasu fosforowego (V)","parameters":[{"name":"Zakres","range":"(0,065 – 2,00) mg/m3"},{"name":"Zakres","range":"(0,000455 – 0,0140) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość kwasu fosforowego (V)\nZakres:\nZakres (0,065 – 2,00) mg/m3\nZakres (0,000455 – 0,0140) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość kwasu fosforowego (V)\nZakres:\nZakres (0,065 – 2,00) mg/m3\nZakres (0,000455 – 0,0140) mg w próbce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc kwasu fosforowego (V)\nZakres:\nZakres (0,065 – 2,00) mg/m3\nZakres (0,000455 – 0,0140) mg w probce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of phosphoric (V) acid","parameters_en":[{"name":"Range","range":"(0,065 – 2,00) mg/m3"},{"name":"Range","range":"(0,000455 – 0,0140) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of phosphoric (V) acid Spectrophotometric method Range Range PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,065 – 2,00) mg/m3"},{"name":"范围","range":"(0,000455 – 0,0140) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 范围 范围 PN-Z-04073-1:2014-08","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83ae76af14b9c0e7b20394","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość chloru","parameters":[{"name":"Zakres","range":"(0,067 – 1,52) mg/m3"},{"name":"Zakres","range":"(0,0010 – 0,0228) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość chloru\nZakres:\nZakres (0,067 – 1,52) mg/m3\nZakres (0,0010 – 0,0228) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037.03","norm_bases":["PN-75/Z-04037.03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość chloru\nZakres:\nZakres (0,067 – 1,52) mg/m3\nZakres (0,0010 – 0,0228) mg w próbce\nMetoda spektrofotometryczna PN-75/Z-04037.03 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc chloru\nZakres:\nZakres (0,067 – 1,52) mg/m3\nZakres (0,0010 – 0,0228) mg w probce\nMetoda spektrofotometryczna PN-75/Z-04037.03","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration / content","parameters_en":[{"name":"Range","range":"(0,067 – 1,52) mg/m3"},{"name":"Range","range":"(0,0010 – 0,0228) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Chlorine concentration / content Spectrophotometric method Range Range PN-75/Z-04037.03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,067 – 1,52) mg/m3"},{"name":"范围","range":"(0,0010 – 0,0228) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 氯的浓度/含量 分光光度法 范围 范围 PN-75/Z-04037.03","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"氯的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20395","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,70 – 20) mg/m3"},{"name":"Zakres","range":"(0,0070 – 0,20) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość siarkowodoru\nZakres:\nZakres (0,70 – 20) mg/m3\nZakres (0,0070 – 0,20) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996","norm_bases":["PN-Z-04015-13:1996"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość siarkowodoru\nZakres:\nZakres (0,70 – 20) mg/m3\nZakres (0,0070 – 0,20) mg w próbce\nMetoda spektrofotometryczna PN-Z-04015-13:1996 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc siarkowodoru\nZakres:\nZakres (0,70 – 20) mg/m3\nZakres (0,0070 – 0,20) mg w probce\nMetoda spektrofotometryczna PN-Z-04015-13:1996","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide concentration / content","parameters_en":[{"name":"Range","range":"(0,70 – 20) mg/m3"},{"name":"Range","range":"(0,0070 – 0,20) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Hydrogen sulphide concentration / content Spectrophotometric method Range Range PN-Z-04015-13:1996","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,70 – 20) mg/m3"},{"name":"范围","range":"(0,0070 – 0,20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 硫化氢的浓度/含量 分光光度法 范围 范围 PN-Z-04015-13:1996","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"硫化氢的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20396","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,75 – 30) mg/m3"},{"name":"Zakres","range":"(0,00750 – 0,30) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość amoniaku\nZakres:\nZakres (0,75 – 30) mg/m3\nZakres (0,00750 – 0,30) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość amoniaku\nZakres:\nZakres (0,75 – 30) mg/m3\nZakres (0,00750 – 0,30) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc amoniaku\nZakres:\nZakres (0,75 – 30) mg/m3\nZakres (0,00750 – 0,30) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration / content","parameters_en":[{"name":"Range","range":"(0,75 – 30) mg/m3"},{"name":"Range","range":"(0,00750 – 0,30) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Ammonia concentration / content Spectrophotometric method Range Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,75 – 30) mg/m3"},{"name":"范围","range":"(0,00750 – 0,30) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 氨的浓度/含量 分光光度法 范围 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"氨的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20397","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość fluorków w przeliczeniu na F -","parameters":[{"name":"Zakres","range":"(0,06 – 60) mg/m3"},{"name":"Zakres","range":"(0,0030 – 3,0) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie / zawartość fluorków w przeliczeniu na F -\nZakres:\nZakres (0,06 – 60) mg/m3\nZakres (0,0030 – 3,0) mg w próbce\nMetoda potencjometryczna","reference":"PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","norm_bases":["PB-61/CzA/W6-24.01.2018","PB-27/W8-29.03.2021"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość fluorków w przeliczeniu na F -\nZakres:\nZakres (0,06 – 60) mg/m3\nZakres (0,0030 – 3,0) mg w próbce\nMetoda potencjometryczna PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc fluorkow w przeliczeniu na F -\nZakres:\nZakres (0,06 – 60) mg/m3\nZakres (0,0030 – 3,0) mg w probce\nMetoda potencjometryczna PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of fluorides expressed as F -","parameters_en":[{"name":"Range","range":"(0,06 – 60) mg/m3"},{"name":"Range","range":"(0,0030 – 3,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of fluorides expressed as F - Potentiometric method Range Range PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","technique_en":"Potentiometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,06 – 60) mg/m3"},{"name":"范围","range":"(0,0030 – 3,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 电位法 范围 范围 PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","technique_zh":"电位法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83ae76af14b9c0e7b20398","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość fluoru, fluorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie / zawartość fluoru, fluorowodoru (z obliczeń)","reference":"PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","norm_bases":["PB-61/CzA/W6-24.01.2018","PB-27/W8-29.03.2021"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość fluoru, fluorowodoru (z obliczeń) PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc fluoru, fluorowodoru (z obliczen) PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of fluorine, hydrogen fluoride (calculated)","search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of fluorine, hydrogen fluoride (calculated) PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 PB-61/CzA/W6-24.01.2018 | PB-27/W8-29.03.2021","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83ae76af14b9c0e7b20399","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość N,N","parameters":[{"name":"dimetyloaniliny (dwumetyloanilina, N-dwumetyloanilina)"},{"name":"Zakres","range":"(1,20 – 80,0) mg/m3"},{"name":"Zakres","range":"(0,0120 – 0,80) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość N,N\nZakres:\ndimetyloaniliny (dwumetyloanilina, N-dwumetyloanilina)\nZakres (1,20 – 80,0) mg/m3\nZakres (0,0120 – 0,80) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-81/Z-04031.02","norm_bases":["PN-81/Z-04031.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość N,N\nZakres:\ndimetyloaniliny (dwumetyloanilina, N-dwumetyloanilina)\nZakres (1,20 – 80,0) mg/m3\nZakres (0,0120 – 0,80) mg w próbce\nMetoda spektrofotometryczna PN-81/Z-04031.02 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc N,N\nZakres:\ndimetyloaniliny (dwumetyloanilina, N-dwumetyloanilina)\nZakres (1,20 – 80,0) mg/m3\nZakres (0,0120 – 0,80) mg w probce\nMetoda spektrofotometryczna PN-81/Z-04031.02","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of N,N","parameters_en":[{"name":"dimethylaniline (dimethylaniline, N-dimethylaniline)"},{"name":"Range","range":"(1,20 – 80,0) mg/m3"},{"name":"Range","range":"(0,0120 – 0,80) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of N,N Spectrophotometric method dimethylaniline (dimethylaniline, N-dimethylaniline) Range Range PN-81/Z-04031.02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"dimetyloaniliny (dwumetyloanilina, N-dwumetyloanilina)"},{"name":"范围","range":"(1,20 – 80,0) mg/m3"},{"name":"范围","range":"(0,0120 – 0,80) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 范围 范围 PN-81/Z-04031.02","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a83ae76af14b9c0e7b2039a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie / zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,0150 – 0,300) mg/m3"},{"name":"Zakres","range":"(0,00060 – 0,0120) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość ozonu\nZakres:\nZakres (0,0150 – 0,300) mg/m3\nZakres (0,00060 – 0,0120) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do roztworu pochłaniającego Stężenie / zawartość ozonu\nZakres:\nZakres (0,0150 – 0,300) mg/m3\nZakres (0,00060 – 0,0120) mg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy – powietrze – probki powietrza pobrane do roztworu pochlaniajacego Stezenie / zawartosc ozonu\nZakres:\nZakres (0,0150 – 0,300) mg/m3\nZakres (0,00060 – 0,0120) mg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ozone","parameters_en":[{"name":"Range","range":"(0,0150 – 0,300) mg/m3"},{"name":"Range","range":"(0,00060 – 0,0120) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into absorbing solution Concentration / content of ozone Spectrophotometric method Range Range PN-Z-04007-2:1994","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,0150 – 0,300) mg/m3"},{"name":"范围","range":"(0,00060 – 0,0120) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 臭氧的浓度/含量 分光光度法 范围 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"臭氧的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b2039b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość izocyjanianów: 2,4-TDI (diizocyjanian tolueno-2,4-diylu, 2,4-diizocyjanianotoluen)","parameters":[{"name":"Zakres","range":"(0,00070 – 0,20) mg/m3"},{"name":"Zakres","range":"(0,10 – 50) μg w próbce"},{"name":"2,6-TDI","range":"( diizocyjanian tolueno-2,6-diylu, 2,6-diizocyjanianotoluen)"},{"name":"Zakres","range":"(0,00070 – 0,20) mg/m3"},{"name":"Zakres","range":"(0,10 – 50) μg w próbce"},{"name":"MDI (metylenobis (fenyloizocyjanian), 4,4'-metylenobis(fenyloizocyjanian)"},{"name":"Zakres","range":"(0,00070 – 0,20) mg/m3"},{"name":"Zakres","range":"(0,10 – 50) μg w próbce"},{"name":"HDI","range":"(diizocyjanian heksano-1,6-diylu, 1,6-heksametylenodiizocyjanian)"},{"name":"Zakres","range":"(0,00070 – 0,20) mg/m3"},{"name":"Zakres","range":"(0,10 – 50) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość izocyjanianów: 2,4-TDI (diizocyjanian tolueno-2,4-diylu, 2,4-diizocyjanianotoluen)\nZakres:\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\n2,6-TDI ( diizocyjanian tolueno-2,6-diylu, 2,6-diizocyjanianotoluen)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\nMDI (metylenobis (fenyloizocyjanian), 4,4'-metylenobis(fenyloizocyjanian)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\nHDI (diizocyjanian heksano-1,6-diylu, 1,6-heksametylenodiizocyjanian)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-61/CzD/W2-01.04.2015 * | PB-102/W2-18.03.2015 *","norm_bases":["PB-61/CzD/W2-01.04.2015 *","PB-102/W2-18.03.2015 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość izocyjanianów: 2,4-TDI (diizocyjanian tolueno-2,4-diylu, 2,4-diizocyjanianotoluen)\nZakres:\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\n2,6-TDI ( diizocyjanian tolueno-2,6-diylu, 2,6-diizocyjanianotoluen)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\nMDI (metylenobis (fenyloizocyjanian), 4,4'-metylenobis(fenyloizocyjanian)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\nHDI (diizocyjanian heksano-1,6-diylu, 1,6-heksametylenodiizocyjanian)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-61/CzD/W2-01.04.2015 * | PB-102/W2-18.03.2015 * Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc izocyjanianow: 2,4-TDI (diizocyjanian tolueno-2,4-diylu, 2,4-diizocyjanianotoluen)\nZakres:\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w probce\n2,6-TDI ( diizocyjanian tolueno-2,6-diylu, 2,6-diizocyjanianotoluen)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w probce\nMDI (metylenobis (fenyloizocyjanian), 4,4'-metylenobis(fenyloizocyjanian)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w probce\nHDI (diizocyjanian heksano-1,6-diylu, 1,6-heksametylenodiizocyjanian)\nZakres (0,00070 – 0,20) mg/m3\nZakres (0,10 – 50) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-61/CzD/W2-01.04.2015 * | PB-102/W2-18.03.2015 *","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of isocyanates: 2,4-TDI (toluene-2,4-diyl diisocyanate, 2,4-diisocyanatotoluene)","parameters_en":[{"name":"Range","range":"(0,00070 – 0,20) mg/m3"},{"name":"Range","range":"(0,10 – 50) μg w próbce"},{"name":"2,6-TDI","range":"( diizocyjanian tolueno-2,6-diylu, 2,6-diizocyjanianotoluen)"},{"name":"Range","range":"(0,00070 – 0,20) mg/m3"},{"name":"Range","range":"(0,10 – 50) μg w próbce"},{"name":"MDI (methylenebis (phenyl isocyanate), 4,4'-methylenebis(phenyl isocyanate)"},{"name":"Range","range":"(0,00070 – 0,20) mg/m3"},{"name":"Range","range":"(0,10 – 50) μg w próbce"},{"name":"HDI","range":"(diizocyjanian heksano-1,6-diylu, 1,6-heksametylenodiizocyjanian)"},{"name":"Range","range":"(0,00070 – 0,20) mg/m3"},{"name":"Range","range":"(0,10 – 50) μg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of isocyanates: 2,4-TDI (toluene-2,4-diyl diisocyanate, 2,4-diisocyanatotoluene) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range Range 2,6-TDI Range Range MDI (methylenebis (phenyl isocyanate), 4,4'-methylenebis(phenyl isocyanate) Range Range HDI Range Range PB-61/CzD/W2-01.04.2015 * | PB-102/W2-18.03.2015 *","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,00070 – 0,20) mg/m3"},{"name":"范围","range":"(0,10 – 50) μg w próbce"},{"name":"2,6-TDI","range":"( diizocyjanian tolueno-2,6-diylu, 2,6-diizocyjanianotoluen)"},{"name":"范围","range":"(0,00070 – 0,20) mg/m3"},{"name":"范围","range":"(0,10 – 50) μg w próbce"},{"name":"MDI (metylenobis (fenyloizocyjanian), 4,4'-metylenobis(fenyloizocyjanian)"},{"name":"范围","range":"(0,00070 – 0,20) mg/m3"},{"name":"范围","range":"(0,10 – 50) μg w próbce"},{"name":"HDI","range":"(diizocyjanian heksano-1,6-diylu, 1,6-heksametylenodiizocyjanian)"},{"name":"范围","range":"(0,00070 – 0,20) mg/m3"},{"name":"范围","range":"(0,10 – 50) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 范围 范围 范围 范围 范围 范围 范围 PB-61/CzD/W2-01.04.2015 * | PB-102/W2-18.03.2015 *","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a83ae76af14b9c0e7b2039c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość benzo(a)pirenu","parameters":[{"name":"Zakres","range":"(0,080 – 6,94) μg/m3"},{"name":"Zakres","range":"(0,050 – 5,0) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość benzo(a)pirenu\nZakres:\nZakres (0,080 – 6,94) μg/m3\nZakres (0,050 – 5,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-2:1999 *","norm_bases":["PN-Z-04240-2:1999 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość benzo(a)pirenu\nZakres:\nZakres (0,080 – 6,94) μg/m3\nZakres (0,050 – 5,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-2:1999 * Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc benzo(a)pirenu\nZakres:\nZakres (0,080 – 6,94) μg/m3\nZakres (0,050 – 5,0) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-2:1999 *","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of benzo(a)pyrene","parameters_en":[{"name":"Range","range":"(0,080 – 6,94) μg/m3"},{"name":"Range","range":"(0,050 – 5,0) μg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of benzo(a)pyrene High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range Range PN-Z-04240-2:1999 *","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,080 – 6,94) μg/m3"},{"name":"范围","range":"(0,050 – 5,0) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 范围 PN-Z-04240-2:1999 *","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a83ae76af14b9c0e7b2039d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość dibenzo(a,h)antracenu","parameters":[{"name":"Zakres","range":"(0,080 – 13,89) μg/m3"},{"name":"Zakres","range":"(0,050 – 10) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość dibenzo(a,h)antracenu\nZakres:\nZakres (0,080 – 13,89) μg/m3\nZakres (0,050 – 10) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-4:1999 *","norm_bases":["PN-Z-04240-4:1999 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość dibenzo(a,h)antracenu\nZakres:\nZakres (0,080 – 13,89) μg/m3\nZakres (0,050 – 10) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-4:1999 * Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc dibenzo(a,h)antracenu\nZakres:\nZakres (0,080 – 13,89) μg/m3\nZakres (0,050 – 10) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-4:1999 *","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of dibenzo(a,h)anthracene","parameters_en":[{"name":"Range","range":"(0,080 – 13,89) μg/m3"},{"name":"Range","range":"(0,050 – 10) μg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of dibenzo(a,h)anthracene High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range Range PN-Z-04240-4:1999 *","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,080 – 13,89) μg/m3"},{"name":"范围","range":"(0,050 – 10) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 范围 PN-Z-04240-4:1999 *","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a83ae76af14b9c0e7b2039e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry i do rurek z sorbentem","methodology":"Stężenie / zawartość WWA","parameters":[{"name":"dibenzo(a,h)antracenu"},{"name":"benzo(a)pirenu"},{"name":"benzo(a)antracenu"},{"name":"benzo(b)fluorantenu"},{"name":"benzo(k)fluorantenu indeno(1,2,3-c,d)pirenu"},{"name":"antracenu"},{"name":"benzo(g,h,i)perylenu"},{"name":"chryzenu"},{"name":"Zakres","range":"(0,09 – 59) μg/m3"},{"name":"Zakres","range":"(0,01 – 5,0) μg w próbce"},{"name":"Wskaźnik narażenia jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość WWA\nZakres:\ndibenzo(a,h)antracenu\nbenzo(a)pirenu\nbenzo(a)antracenu\nbenzo(b)fluorantenu\nbenzo(k)fluorantenu indeno(1,2,3-c,d)pirenu\nantracenu\nbenzo(g,h,i)perylenu\nchryzenu\nZakres (0,09 – 59) μg/m3\nZakres (0,01 – 5,0) μg w próbce\nWskaźnik narażenia jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-Z-04240-5:2006 *","norm_bases":["PN-Z-04240-5:2006 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry i do rurek z sorbentem Stężenie / zawartość WWA\nZakres:\ndibenzo(a,h)antracenu\nbenzo(a)pirenu\nbenzo(a)antracenu\nbenzo(b)fluorantenu\nbenzo(k)fluorantenu indeno(1,2,3-c,d)pirenu\nantracenu\nbenzo(g,h,i)perylenu\nchryzenu\nZakres (0,09 – 59) μg/m3\nZakres (0,01 – 5,0) μg w próbce\nWskaźnik narażenia jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-Z-04240-5:2006 * Srodowisko pracy – powietrze – probki powietrza pobrane na filtry i do rurek z sorbentem Stezenie / zawartosc WWA\nZakres:\ndibenzo(a,h)antracenu\nbenzo(a)pirenu\nbenzo(a)antracenu\nbenzo(b)fluorantenu\nbenzo(k)fluorantenu indeno(1,2,3-c,d)pirenu\nantracenu\nbenzo(g,h,i)perylenu\nchryzenu\nZakres (0,09 – 59) μg/m3\nZakres (0,01 – 5,0) μg w probce\nWskaznik narazenia jako suma iloczynow stezen i wspolczynnikow rakotworczosci 9 rakotworczych WWA (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-Z-04240-5:2006 *","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of PAH","parameters_en":[{"name":"dibenzo(a,h)anthracene"},{"name":"benzo(a)pyrene"},{"name":"benzo(a)anthracene"},{"name":"benzo(b)fluoranthene"},{"name":"benzo(k)fluoranthene indeno(1,2,3-c,d)pyrene"},{"name":"anthracene"},{"name":"benzo(g,h,i)perylene"},{"name":"chrysene"},{"name":"Range","range":"(0,09 – 59) μg/m3"},{"name":"Range","range":"(0,01 – 5,0) μg w próbce"},{"name":"Exposure index as the sum of the products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs (calculated)"}],"search_en":"Workplace environment – air – air samples collected on filters and into sorbent tubes Concentration / content of PAH High-performance liquid chromatography with fluorescence detection (HPLC-FLD) dibenzo(a,h)anthracene benzo(a)pyrene benzo(a)anthracene benzo(b)fluoranthene benzo(k)fluoranthene indeno(1,2,3-c,d)pyrene anthracene benzo(g,h,i)perylene chrysene Range Range Exposure index as the sum of the products of concentrations and carcinogenicity factors of 9 carcinogenic PAHs (calculated) PN-Z-04240-5:2006 *","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Workplace environment – air – air samples collected on filters and into sorbent tubes","parameters_zh":[{"name":"二苯并(a,h)蒽"},{"name":"苯并(a)芘"},{"name":"苯并(a)蒽"},{"name":"苯并(b)荧蒽"},{"name":"benzo(k)fluorantenu indeno(1,2,3-c,d)pirenu"},{"name":"蒽"},{"name":"benzo(g,h,i)perylenu"},{"name":"䓛"},{"name":"范围","range":"(0,09 – 59) μg/m3"},{"name":"范围","range":"(0,01 – 5,0) μg w próbce"},{"name":"Wskaźnik narażenia jako suma iloczynów stężeń i współczynników rakotwórczości 9 rakotwórczych WWA (z obliczeń)"}],"search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） 二苯并(a,h)蒽 苯并(a)芘 苯并(a)蒽 苯并(b)荧蒽 蒽 䓛 范围 范围 PN-Z-04240-5:2006 *","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a83ae76af14b9c0e7b2039f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość krystalicznej krzemionki (kwarc i krystobalit)","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0038 – 0,58) mg/m3"},{"name":"Zakres","range":"(0,006 – 0,40) mg w próbce"},{"name":"Fouriera (FT-IR)"}],"technique":"Metoda spektrometrii w zakresie podczerwieni z transformacją","techniques":["Metoda spektrometrii w zakresie podczerwieni z transformacją"],"computed":[],"activity":"Stężenie / zawartość krystalicznej krzemionki (kwarc i krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0038 – 0,58) mg/m3\nZakres (0,006 – 0,40) mg w próbce\nFouriera (FT-IR)\nMetoda spektrometrii w zakresie podczerwieni z transformacją","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość krystalicznej krzemionki (kwarc i krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0038 – 0,58) mg/m3\nZakres (0,006 – 0,40) mg w próbce\nFouriera (FT-IR)\nMetoda spektrometrii w zakresie podczerwieni z transformacją Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc krystalicznej krzemionki (kwarc i krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,0038 – 0,58) mg/m3\nZakres (0,006 – 0,40) mg w probce\nFouriera (FT-IR)\nMetoda spektrometrii w zakresie podczerwieni z transformacja Podstawy i Metody Oceny Srodowiska Pracy 2012, Nr 4 (74), str. 117-130","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of crystalline silica (quartz and cristobalite)","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,0038 – 0,58) mg/m3"},{"name":"Range","range":"(0,006 – 0,40) mg w próbce"},{"name":"Fourier (FT-IR)"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of crystalline silica (quartz and cristobalite) Infrared spectrometry with transform respirable fraction Range Range Fourier (FT-IR) Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130","technique_en":"Infrared spectrometry with transform","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,0038 – 0,58) mg/m3"},{"name":"范围","range":"(0,006 – 0,40) mg w próbce"},{"name":"傅里叶（FT-IR）"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 傅里叶变换红外光谱法 呼吸性组分 范围 范围 傅里叶（FT-IR） Podstawy i Metody Oceny Środowiska Pracy 2012, Nr 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","technique_zh":"傅里叶变换红外光谱法"},{"_id":"6a83ae76af14b9c0e7b203a0","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,208 – 20,83) mg/ m3"},{"name":"Zakres","range":"(0,2 – 15) mg w próbce"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (FT-IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (FT-IR)"],"computed":[],"activity":"Stężenie / zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres:\nZakres (0,208 – 20,83) mg/ m3\nZakres (0,2 – 15) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni (FT-IR)","reference":"PN-Z-04108-5:2006","norm_bases":["PN-Z-04108-5:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres:\nZakres (0,208 – 20,83) mg/ m3\nZakres (0,2 – 15) mg w próbce\nMetoda spektrometrii w zakresie podczerwieni (FT-IR) PN-Z-04108-5:2006 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc olejow mineralnych wysokorafinowanych z wylaczeniem cieczy obrobkowych – frakcja wdychalna\nZakres:\nZakres (0,208 – 20,83) mg/ m3\nZakres (0,2 – 15) mg w probce\nMetoda spektrometrii w zakresie podczerwieni (FT-IR) PN-Z-04108-5:2006","categories":["environment","petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of highly refined mineral oils excluding metalworking fluids – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,208 – 20,83) mg/ m3"},{"name":"Range","range":"(0,2 – 15) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of highly refined mineral oils excluding metalworking fluids – inhalable fraction Infrared spectrometry (FT-IR) Range Range PN-Z-04108-5:2006","technique_en":"Infrared spectrometry (FT-IR)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,208 – 20,83) mg/ m3"},{"name":"范围","range":"(0,2 – 15) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 红外光谱法（FT-IR） 范围 范围 PN-Z-04108-5:2006","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","technique_zh":"红外光谱法（FT-IR）"},{"_id":"6a83ae76af14b9c0e7b203a1","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość chlorku amonu pary i frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,13 – 40) mg/m3"},{"name":"Zakres","range":"(0,50 – 15) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość chlorku amonu pary i frakcja wdychalna\nZakres:\nZakres (0,13 – 40) mg/m3\nZakres (0,50 – 15) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04265:2000","norm_bases":["PN-Z-04265:2000"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość chlorku amonu pary i frakcja wdychalna\nZakres:\nZakres (0,13 – 40) mg/m3\nZakres (0,50 – 15) mg w próbce\nMetoda spektrofotometryczna PN-Z-04265:2000 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc chlorku amonu pary i frakcja wdychalna\nZakres:\nZakres (0,13 – 40) mg/m3\nZakres (0,50 – 15) mg w probce\nMetoda spektrofotometryczna PN-Z-04265:2000","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ammonium chloride vapours and inhalable fraction","parameters_en":[{"name":"Range","range":"(0,13 – 40) mg/m3"},{"name":"Range","range":"(0,50 – 15) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of ammonium chloride vapours and inhalable fraction Spectrophotometric method Range Range PN-Z-04265:2000","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,13 – 40) mg/m3"},{"name":"范围","range":"(0,50 – 15) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 分光光度法 范围 范围 PN-Z-04265:2000","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a83ae76af14b9c0e7b203a2","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/m3"},{"name":"Zakres","range":"(0,360 – 7,20) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,50 – 10,0) mg/m3\nZakres (0,360 – 7,20) mg w próbce\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,50 – 10,0) mg/m3\nZakres (0,360 – 7,20) mg w próbce\nMetoda turbidymetryczna PN-Z-04450:2014-08 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc chlorowodoru\nZakres:\nZakres (0,50 – 10,0) mg/m3\nZakres (0,360 – 7,20) mg w probce\nMetoda turbidymetryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration / content","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/m3"},{"name":"Range","range":"(0,360 – 7,20) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Hydrogen chloride concentration / content Turbidimetric method Range Range PN-Z-04450:2014-08","technique_en":"Turbidimetric method","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/m3"},{"name":"范围","range":"(0,360 – 7,20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 氯化氢的浓度/含量 浊度法 范围 范围 PN-Z-04450:2014-08","technique_zh":"浊度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203a3","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość acetonu","parameters":[{"name":"Zakres","range":"(31,2 – 3600) mg/m3"},{"name":"Zakres","range":"(0,50 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość acetonu\nZakres:\nZakres (31,2 – 3600) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość acetonu\nZakres:\nZakres (31,2 – 3600) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc acetonu\nZakres:\nZakres (31,2 – 3600) mg/m3\nZakres (0,50 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acetone","parameters_en":[{"name":"Range","range":"(31,2 – 3600) mg/m3"},{"name":"Range","range":"(0,50 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of acetone Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(31,2 – 3600) mg/m3"},{"name":"范围","range":"(0,50 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203a4","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość toluenu","parameters":[{"name":"Zakres","range":"(0,083 – 417) mg/m3"},{"name":"Zakres","range":"(0,0010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość toluenu\nZakres:\nZakres (0,083 – 417) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość toluenu\nZakres:\nZakres (0,083 – 417) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc toluenu\nZakres:\nZakres (0,083 – 417) mg/m3\nZakres (0,0010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of toluene","parameters_en":[{"name":"Range","range":"(0,083 – 417) mg/m3"},{"name":"Range","range":"(0,0010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of toluene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,083 – 417) mg/m3"},{"name":"范围","range":"(0,0010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203a5","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość etanolu (alkoholu etylowego)","parameters":[{"name":"Zakres","range":"(62,5 – 3800) mg/m3"},{"name":"Zakres","range":"(1,0 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość etanolu (alkoholu etylowego)\nZakres:\nZakres (62,5 – 3800) mg/m3\nZakres (1,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość etanolu (alkoholu etylowego)\nZakres:\nZakres (62,5 – 3800) mg/m3\nZakres (1,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc etanolu (alkoholu etylowego)\nZakres:\nZakres (62,5 – 3800) mg/m3\nZakres (1,0 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ethanol (ethyl alcohol)","parameters_en":[{"name":"Range","range":"(62,5 – 3800) mg/m3"},{"name":"Range","range":"(1,0 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of ethanol (ethyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(62,5 – 3800) mg/m3"},{"name":"范围","range":"(1,0 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203a6","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość ksylenu","parameters":[{"name":"Zakres","range":"(0,062 – 400) mg/m3"},{"name":"Zakres","range":"(0,0010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość ksylenu\nZakres:\nZakres (0,062 – 400) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość ksylenu\nZakres:\nZakres (0,062 – 400) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc ksylenu\nZakres:\nZakres (0,062 – 400) mg/m3\nZakres (0,0010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of xylene","parameters_en":[{"name":"Range","range":"(0,062 – 400) mg/m3"},{"name":"Range","range":"(0,0010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of xylene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 400) mg/m3"},{"name":"范围","range":"(0,0010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203a7","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość butan-1-olu (alkoholu n-butylowego)","parameters":[{"name":"Zakres","range":"(0,062 – 300) mg/m3"},{"name":"Zakres","range":"(0,0010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość butan-1-olu (alkoholu n-butylowego)\nZakres:\nZakres (0,062 – 300) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość butan-1-olu (alkoholu n-butylowego)\nZakres:\nZakres (0,062 – 300) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc butan-1-olu (alkoholu n-butylowego)\nZakres:\nZakres (0,062 – 300) mg/m3\nZakres (0,0010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of butan-1-ol (n-butyl alcohol)","parameters_en":[{"name":"Range","range":"(0,062 – 300) mg/m3"},{"name":"Range","range":"(0,0010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of butan-1-ol (n-butyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 300) mg/m3"},{"name":"范围","range":"(0,0010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203a8","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość octanu etylu","parameters":[{"name":"Zakres","range":"(31,2 – 2936) mg/m3"},{"name":"Zakres","range":"(8,5 – 801) ppm"},{"name":"Zakres","range":"(0,50 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu etylu\nZakres:\nZakres (31,2 – 2936) mg/m3\nZakres (8,5 – 801) ppm\nZakres (0,50 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość octanu etylu\nZakres:\nZakres (31,2 – 2936) mg/m3\nZakres (8,5 – 801) ppm\nZakres (0,50 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc octanu etylu\nZakres:\nZakres (31,2 – 2936) mg/m3\nZakres (8,5 – 801) ppm\nZakres (0,50 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ethyl acetate","parameters_en":[{"name":"Range","range":"(31,2 – 2936) mg/m3"},{"name":"Range","range":"(8,5 – 801) ppm"},{"name":"Range","range":"(0,50 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of ethyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(31,2 – 2936) mg/m3"},{"name":"范围","range":"(8,5 – 801) ppm"},{"name":"范围","range":"(0,50 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203a9","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość octanu n-butylu","parameters":[{"name":"Zakres","range":"(0,062 – 1440) mg/m3"},{"name":"Zakres","range":"(0,0010 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu n-butylu\nZakres:\nZakres (0,062 – 1440) mg/m3\nZakres (0,0010 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość octanu n-butylu\nZakres:\nZakres (0,062 – 1440) mg/m3\nZakres (0,0010 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc octanu n-butylu\nZakres:\nZakres (0,062 – 1440) mg/m3\nZakres (0,0010 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of n-butyl acetate","parameters_en":[{"name":"Range","range":"(0,062 – 1440) mg/m3"},{"name":"Range","range":"(0,0010 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of n-butyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 1440) mg/m3"},{"name":"范围","range":"(0,0010 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203aa","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość 2-butoksyetanolu (alkoholu butoksyetylowego)","parameters":[{"name":"Zakres","range":"(0,62 – 400) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-butoksyetanolu (alkoholu butoksyetylowego)\nZakres:\nZakres (0,62 – 400) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość 2-butoksyetanolu (alkoholu butoksyetylowego)\nZakres:\nZakres (0,62 – 400) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc 2-butoksyetanolu (alkoholu butoksyetylowego)\nZakres:\nZakres (0,62 – 400) mg/m3\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-butoxyethanol (butoxyethyl alcohol)","parameters_en":[{"name":"Range","range":"(0,62 – 400) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 2-butoxyethanol (butoxyethyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 400) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203ab","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość 2-metylopropan-1-olu (alkoholu izobutylowego)","parameters":[{"name":"Zakres","range":"(0,83 – 417) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-metylopropan-1-olu (alkoholu izobutylowego)\nZakres:\nZakres (0,83 – 417) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023.02 IR-230/W5-08.03.2019","norm_bases":["PN-89/Z-04023.02 IR-230/W5-08.03.2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość 2-metylopropan-1-olu (alkoholu izobutylowego)\nZakres:\nZakres (0,83 – 417) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc 2-metylopropan-1-olu (alkoholu izobutylowego)\nZakres:\nZakres (0,83 – 417) mg/m3\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023.02 IR-230/W5-08.03.2019","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-methylpropan-1-ol (isobutyl alcohol)","parameters_en":[{"name":"Range","range":"(0,83 – 417) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 2-methylpropan-1-ol (isobutyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,83 – 417) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-89/Z-04023.02 IR-230/W5-08.03.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203ac","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,062 – 3,2) mg/m3"},{"name":"Zakres","range":"(0,019 – 1,0) ppm"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość benzenu\nZakres:\nZakres (0,062 – 3,2) mg/m3\nZakres (0,019 – 1,0) ppm\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość benzenu\nZakres:\nZakres (0,062 – 3,2) mg/m3\nZakres (0,019 – 1,0) ppm\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc benzenu\nZakres:\nZakres (0,062 – 3,2) mg/m3\nZakres (0,019 – 1,0) ppm\nZakres (0,0010 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene concentration / content","parameters_en":[{"name":"Range","range":"(0,062 – 3,2) mg/m3"},{"name":"Range","range":"(0,019 – 1,0) ppm"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Benzene concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04016-10:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 3,2) mg/m3"},{"name":"范围","range":"(0,019 – 1,0) ppm"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"苯的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203ad","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość etylobenzenu","parameters":[{"name":"Zakres","range":"(0,062 – 800) mg/m3"},{"name":"Zakres","range":"(0,0010 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość etylobenzenu\nZakres:\nZakres (0,062 – 800) mg/m3\nZakres (0,0010 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-79/Z-04081.01","norm_bases":["PN-79/Z-04081.01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość etylobenzenu\nZakres:\nZakres (0,062 – 800) mg/m3\nZakres (0,0010 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-79/Z-04081.01 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc etylobenzenu\nZakres:\nZakres (0,062 – 800) mg/m3\nZakres (0,0010 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-79/Z-04081.01","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ethylbenzene","parameters_en":[{"name":"Range","range":"(0,062 – 800) mg/m3"},{"name":"Range","range":"(0,0010 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of ethylbenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-79/Z-04081.01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 800) mg/m3"},{"name":"范围","range":"(0,0010 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-79/Z-04081.01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203ae","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość kumenu (izopropylobenzenu)","parameters":[{"name":"Zakres","range":"(0,62 – 500) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość kumenu (izopropylobenzenu)\nZakres:\nZakres (0,62 – 500) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-6:1998","norm_bases":["PN-Z-04016-6:1998"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość kumenu (izopropylobenzenu)\nZakres:\nZakres (0,62 – 500) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-6:1998 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc kumenu (izopropylobenzenu)\nZakres:\nZakres (0,62 – 500) mg/m3\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-6:1998","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cumene (isopropylbenzene)","parameters_en":[{"name":"Range","range":"(0,62 – 500) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of cumene (isopropylbenzene) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-6:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 500) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-6:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203af","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość trimetylobenzenu","parameters":[{"name":"Zakres","range":"(0,62 – 340) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość trimetylobenzenu\nZakres:\nZakres (0,62 – 340) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-4:1998","norm_bases":["PN-Z-04016-4:1998"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość trimetylobenzenu\nZakres:\nZakres (0,62 – 340) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-4:1998 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc trimetylobenzenu\nZakres:\nZakres (0,62 – 340) mg/m3\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-4:1998","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of trimethylbenzene","parameters_en":[{"name":"Range","range":"(0,62 – 340) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of trimethylbenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-4:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 340) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-4:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b0","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość butan -2-onu (metyloetyloketonu)","parameters":[{"name":"Zakres","range":"(6,2 – 1800) mg/m3"},{"name":"Zakres","range":"(0,1 – 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość butan -2-onu (metyloetyloketonu)\nZakres:\nZakres (6,2 – 1800) mg/m3\nZakres (0,1 – 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04449:2014-06","norm_bases":["PN-Z-04449:2014-06"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość butan -2-onu (metyloetyloketonu)\nZakres:\nZakres (6,2 – 1800) mg/m3\nZakres (0,1 – 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04449:2014-06 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc butan -2-onu (metyloetyloketonu)\nZakres:\nZakres (6,2 – 1800) mg/m3\nZakres (0,1 – 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04449:2014-06","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of butan -2-one (methyl ethyl ketone)","parameters_en":[{"name":"Range","range":"(6,2 – 1800) mg/m3"},{"name":"Range","range":"(0,1 – 15) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of butan -2-one (methyl ethyl ketone) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04449:2014-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 1800) mg/m3"},{"name":"范围","range":"(0,1 – 15) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04449:2014-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b1","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość 1-metoksypropan-2-olu","parameters":[{"name":"Zakres","range":"(6,2 – 720) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 1-metoksypropan-2-olu\nZakres:\nZakres (6,2 – 720) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04354:2005","norm_bases":["PN-Z-04354:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość 1-metoksypropan-2-olu\nZakres:\nZakres (6,2 – 720) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04354:2005 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc 1-metoksypropan-2-olu\nZakres:\nZakres (6,2 – 720) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04354:2005","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 1-methoxypropan-2-ol","parameters_en":[{"name":"Range","range":"(6,2 – 720) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 1-methoxypropan-2-ol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04354:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 720) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 1-甲氧基-2-丙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04354:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"1-甲氧基-2-丙醇的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203b2","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość propan-2-olu (alkoholu izopropylowego)","parameters":[{"name":"Zakres","range":"(31,2 – 2400) mg/m3"},{"name":"Zakres","range":"(0,50 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość propan-2-olu (alkoholu izopropylowego)\nZakres:\nZakres (31,2 – 2400) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04224-02:1992","norm_bases":["PN-Z-04224-02:1992"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość propan-2-olu (alkoholu izopropylowego)\nZakres:\nZakres (31,2 – 2400) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04224-02:1992 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc propan-2-olu (alkoholu izopropylowego)\nZakres:\nZakres (31,2 – 2400) mg/m3\nZakres (0,50 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04224-02:1992","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of propan-2-ol (isopropyl alcohol)","parameters_en":[{"name":"Range","range":"(31,2 – 2400) mg/m3"},{"name":"Range","range":"(0,50 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of propan-2-ol (isopropyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04224-02:1992","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(31,2 – 2400) mg/m3"},{"name":"范围","range":"(0,50 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04224-02:1992","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b3","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość propan-1-olu (alkoholu propylowego)","parameters":[{"name":"Zakres","range":"(6,2 – 1200) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość propan-1-olu (alkoholu propylowego)\nZakres:\nZakres (6,2 – 1200) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04224-3:2003","norm_bases":["PN-Z-04224-3:2003"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość propan-1-olu (alkoholu propylowego)\nZakres:\nZakres (6,2 – 1200) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04224-3:2003 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc propan-1-olu (alkoholu propylowego)\nZakres:\nZakres (6,2 – 1200) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04224-3:2003","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of propan-1-ol (propyl alcohol)","parameters_en":[{"name":"Range","range":"(6,2 – 1200) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of propan-1-ol (propyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04224-3:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 1200) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04224-3:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b4","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość styrenu","parameters":[{"name":"Zakres","range":"(0,62 – 200) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość styrenu\nZakres:\nZakres (0,62 – 200) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04152.02","norm_bases":["PN-86/Z-04152.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość styrenu\nZakres:\nZakres (0,62 – 200) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04152.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc styrenu\nZakres:\nZakres (0,62 – 200) mg/m3\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04152.02","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Styrene concentration / content","parameters_en":[{"name":"Range","range":"(0,62 – 200) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Styrene concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-86/Z-04152.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 200) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 苯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-86/Z-04152.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"苯乙烯的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203b5","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość 4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)","parameters":[{"name":"Zakres","range":"(0,62 – 400) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)\nZakres:\nZakres (0,62 – 400) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04165.02","norm_bases":["PN-86/Z-04165.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość 4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)\nZakres:\nZakres (0,62 – 400) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04165.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc 4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)\nZakres:\nZakres (0,62 – 400) mg/m3\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04165.02","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 4-methylpentan-2-one (methyl isobutyl ketone, hexone)","parameters_en":[{"name":"Range","range":"(0,62 – 400) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 4-methylpentan-2-one (methyl isobutyl ketone, hexone) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-86/Z-04165.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 400) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-86/Z-04165.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b6","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)","parameters":[{"name":"Zakres","range":"(6,2 – 480) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)\nZakres:\nZakres (6,2 – 480) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04368:2008","norm_bases":["PN-Z-04368:2008"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość 4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)\nZakres:\nZakres (6,2 – 480) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04368:2008 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc 4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)\nZakres:\nZakres (6,2 – 480) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04368:2008","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 4-hydroxy-4-methylpentan-2-one (diacetone alcohol)","parameters_en":[{"name":"Range","range":"(6,2 – 480) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 4-hydroxy-4-methylpentan-2-one (diacetone alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04368:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 480) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04368:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b7","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(6,2 – 3000) mg/m3"},{"name":"Zakres","range":"(0,1 – 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (6,2 – 3000) mg/m3\nZakres (0,1 – 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81/Z-04134.02","norm_bases":["PN-81/Z-04134.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (6,2 – 3000) mg/m3\nZakres (0,1 – 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81/Z-04134.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc benzyny ekstrakcyjnej\nZakres:\nZakres (6,2 – 3000) mg/m3\nZakres (0,1 – 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81/Z-04134.02","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of extraction naphtha","parameters_en":[{"name":"Range","range":"(6,2 – 3000) mg/m3"},{"name":"Range","range":"(0,1 – 20) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of extraction naphtha Gas chromatography with flame ionization detection (GC-FID) Range Range PN-81/Z-04134.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 3000) mg/m3"},{"name":"范围","range":"(0,1 – 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-81/Z-04134.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b8","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość benzyny do lakierów","parameters":[{"name":"Zakres","range":"(6,2 – 1800) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość benzyny do lakierów\nZakres:\nZakres (6,2 – 1800) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81/Z-04134.03","norm_bases":["PN-81/Z-04134.03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość benzyny do lakierów\nZakres:\nZakres (6,2 – 1800) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81/Z-04134.03 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc benzyny do lakierow\nZakres:\nZakres (6,2 – 1800) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81/Z-04134.03","categories":["environment","automotive"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of white spirit","parameters_en":[{"name":"Range","range":"(6,2 – 1800) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of white spirit Gas chromatography with flame ionization detection (GC-FID) Range Range PN-81/Z-04134.03","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 1800) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-81/Z-04134.03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203b9","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość trichloroetenu (trójchloroetylenu)","parameters":[{"name":"Zakres","range":"(0,062 – 200) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość trichloroetenu (trójchloroetylenu)\nZakres:\nZakres (0,062 – 200) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78/Z-04047.02","norm_bases":["PN-78/Z-04047.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość trichloroetenu (trójchloroetylenu)\nZakres:\nZakres (0,062 – 200) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78/Z-04047.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc trichloroetenu (trojchloroetylenu)\nZakres:\nZakres (0,062 – 200) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78/Z-04047.02","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of trichloroethene (trichloroethylene)","parameters_en":[{"name":"Range","range":"(0,062 – 200) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of trichloroethene (trichloroethylene) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-78/Z-04047.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 200) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-78/Z-04047.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203ba","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość pentanu","parameters":[{"name":"Zakres","range":"(125 – 6000) mg/m3"},{"name":"Zakres","range":"(2,0 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość pentanu\nZakres:\nZakres (125 – 6000) mg/m3\nZakres (2,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość pentanu\nZakres:\nZakres (125 – 6000) mg/m3\nZakres (2,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc pentanu\nZakres:\nZakres (125 – 6000) mg/m3\nZakres (2,0 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pentane concentration / content","parameters_en":[{"name":"Range","range":"(125 – 6000) mg/m3"},{"name":"Range","range":"(2,0 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Pentane concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04318:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(125 – 6000) mg/m3"},{"name":"范围","range":"(2,0 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 戊烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"戊烷的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203bb","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość heksanu","parameters":[{"name":"Zakres","range":"(0,062 – 144) mg/m3"},{"name":"Zakres","range":"(0,0010 – 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość heksanu\nZakres:\nZakres (0,062 – 144) mg/m3\nZakres (0,0010 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04136-3:2003","norm_bases":["PN-Z-04136-3:2003"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość heksanu\nZakres:\nZakres (0,062 – 144) mg/m3\nZakres (0,0010 – 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04136-3:2003 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc heksanu\nZakres:\nZakres (0,062 – 144) mg/m3\nZakres (0,0010 – 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04136-3:2003","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of hexane","parameters_en":[{"name":"Range","range":"(0,062 – 144) mg/m3"},{"name":"Range","range":"(0,0010 – 5) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of hexane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04136-3:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 144) mg/m3"},{"name":"范围","range":"(0,0010 – 5) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04136-3:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203bc","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość heptanu","parameters":[{"name":"Zakres","range":"(62,5 – 4000) mg/m3"},{"name":"Zakres","range":"(1,0 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość heptanu\nZakres:\nZakres (62,5 – 4000) mg/m3\nZakres (1,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-84/Z-04138.02","norm_bases":["PN-84/Z-04138.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość heptanu\nZakres:\nZakres (62,5 – 4000) mg/m3\nZakres (1,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-84/Z-04138.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc heptanu\nZakres:\nZakres (62,5 – 4000) mg/m3\nZakres (1,0 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-84/Z-04138.02","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of heptane","parameters_en":[{"name":"Range","range":"(62,5 – 4000) mg/m3"},{"name":"Range","range":"(1,0 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of heptane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-84/Z-04138.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(62,5 – 4000) mg/m3"},{"name":"范围","range":"(1,0 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 正庚烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-84/Z-04138.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"正庚烷的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203bd","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość oktanu","parameters":[{"name":"Zakres","range":"(31,2 – 3600) mg/m3"},{"name":"Zakres","range":"(0,50 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość oktanu\nZakres:\nZakres (31,2 – 3600) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04166.02","norm_bases":["PN-86/Z-04166.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość oktanu\nZakres:\nZakres (31,2 – 3600) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04166.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc oktanu\nZakres:\nZakres (31,2 – 3600) mg/m3\nZakres (0,50 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04166.02","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of octane","parameters_en":[{"name":"Range","range":"(31,2 – 3600) mg/m3"},{"name":"Range","range":"(0,50 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of octane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-86/Z-04166.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(31,2 – 3600) mg/m3"},{"name":"范围","range":"(0,50 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-86/Z-04166.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203be","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość cykloheksanu","parameters":[{"name":"Zakres","range":"(6,2 – 2000) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość cykloheksanu\nZakres:\nZakres (6,2 – 2000) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04151.02","norm_bases":["PN-86/Z-04151.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość cykloheksanu\nZakres:\nZakres (6,2 – 2000) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04151.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc cykloheksanu\nZakres:\nZakres (6,2 – 2000) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04151.02","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cyclohexane","parameters_en":[{"name":"Range","range":"(6,2 – 2000) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of cyclohexane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-86/Z-04151.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 2000) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-86/Z-04151.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203bf","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość metylocykloheksanu","parameters":[{"name":"Zakres","range":"(62,5 – 6000) mg/m3"},{"name":"Zakres","range":"(1,0 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość metylocykloheksanu\nZakres:\nZakres (62,5 – 6000) mg/m3\nZakres (1,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04137-02:1984","norm_bases":["PN-Z-04137-02:1984"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość metylocykloheksanu\nZakres:\nZakres (62,5 – 6000) mg/m3\nZakres (1,0 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04137-02:1984 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc metylocykloheksanu\nZakres:\nZakres (62,5 – 6000) mg/m3\nZakres (1,0 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04137-02:1984","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of methylcyclohexane","parameters_en":[{"name":"Range","range":"(62,5 – 6000) mg/m3"},{"name":"Range","range":"(1,0 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of methylcyclohexane Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04137-02:1984","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(62,5 – 6000) mg/m3"},{"name":"范围","range":"(1,0 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04137-02:1984","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c0","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość cykloheksanonu","parameters":[{"name":"Zakres","range":"(0,062 – 160) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość cykloheksanonu\nZakres:\nZakres (0,062 – 160) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04447:2014-06","norm_bases":["PN-Z-04447:2014-06"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość cykloheksanonu\nZakres:\nZakres (0,062 – 160) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04447:2014-06 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc cykloheksanonu\nZakres:\nZakres (0,062 – 160) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04447:2014-06","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cyclohexanone","parameters_en":[{"name":"Range","range":"(0,062 – 160) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of cyclohexanone Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04447:2014-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 160) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 环己酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04447:2014-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"环己酮的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203c1","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość cykloheksanolu","parameters":[{"name":"Zakres","range":"(0,312 – 20) mg/m3"},{"name":"Zakres","range":"(0,005 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość cykloheksanolu\nZakres:\nZakres (0,312 – 20) mg/m3\nZakres (0,005 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04448:2014-06","norm_bases":["PN-Z-04448:2014-06"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość cykloheksanolu\nZakres:\nZakres (0,312 – 20) mg/m3\nZakres (0,005 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04448:2014-06 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc cykloheksanolu\nZakres:\nZakres (0,312 – 20) mg/m3\nZakres (0,005 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04448:2014-06","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of cyclohexanol","parameters_en":[{"name":"Range","range":"(0,312 – 20) mg/m3"},{"name":"Range","range":"(0,005 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of cyclohexanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04448:2014-06","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,312 – 20) mg/m3"},{"name":"范围","range":"(0,005 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04448:2014-06","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c2","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość chloroformu","parameters":[{"name":"Zakres","range":"(0,312 – 16) mg/m3"},{"name":"Zakres","range":"(0,005 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość chloroformu\nZakres:\nZakres (0,312 – 16) mg/m3\nZakres (0,005 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-88/Z-04187.02","norm_bases":["PN-88/Z-04187.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość chloroformu\nZakres:\nZakres (0,312 – 16) mg/m3\nZakres (0,005 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-88/Z-04187.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc chloroformu\nZakres:\nZakres (0,312 – 16) mg/m3\nZakres (0,005 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-88/Z-04187.02","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of chloroform","parameters_en":[{"name":"Range","range":"(0,312 – 16) mg/m3"},{"name":"Range","range":"(0,005 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of chloroform Gas chromatography with flame ionization detection (GC-FID) Range Range PN-88/Z-04187.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,312 – 16) mg/m3"},{"name":"范围","range":"(0,005 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 三氯甲烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-88/Z-04187.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"三氯甲烷的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203c3","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość dichlorometanu","parameters":[{"name":"Zakres","range":"(0,62 – 707) mg/m3"},{"name":"Zakres","range":"(0,18 – 200) ppm"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość dichlorometanu\nZakres:\nZakres (0,62 – 707) mg/m3\nZakres (0,18 – 200) ppm\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-77/Z-04110.01","norm_bases":["PN-77/Z-04110.01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość dichlorometanu\nZakres:\nZakres (0,62 – 707) mg/m3\nZakres (0,18 – 200) ppm\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-77/Z-04110.01 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc dichlorometanu\nZakres:\nZakres (0,62 – 707) mg/m3\nZakres (0,18 – 200) ppm\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-77/Z-04110.01","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of dichloromethane","parameters_en":[{"name":"Range","range":"(0,62 – 707) mg/m3"},{"name":"Range","range":"(0,18 – 200) ppm"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of dichloromethane Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-77/Z-04110.01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 707) mg/m3"},{"name":"范围","range":"(0,18 – 200) ppm"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-77/Z-04110.01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c4","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość tetrachloroetenu (tetrachloroetylenu)","parameters":[{"name":"Zakres","range":"(0,062 – 340) mg/m3"},{"name":"Zakres","range":"(0,0090 – 49) ppm"},{"name":"Zakres","range":"(0,0010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość tetrachloroetenu (tetrachloroetylenu)\nZakres:\nZakres (0,062 – 340) mg/m3\nZakres (0,0090 – 49) ppm\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78/Z-04118.01","norm_bases":["PN-78/Z-04118.01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość tetrachloroetenu (tetrachloroetylenu)\nZakres:\nZakres (0,062 – 340) mg/m3\nZakres (0,0090 – 49) ppm\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78/Z-04118.01 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc tetrachloroetenu (tetrachloroetylenu)\nZakres:\nZakres (0,062 – 340) mg/m3\nZakres (0,0090 – 49) ppm\nZakres (0,0010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78/Z-04118.01","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of tetrachloroethene (tetrachloroethylene)","parameters_en":[{"name":"Range","range":"(0,062 – 340) mg/m3"},{"name":"Range","range":"(0,0090 – 49) ppm"},{"name":"Range","range":"(0,0010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of tetrachloroethene (tetrachloroethylene) Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-78/Z-04118.01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 340) mg/m3"},{"name":"范围","range":"(0,0090 – 49) ppm"},{"name":"范围","range":"(0,0010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-78/Z-04118.01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c5","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość tetrachlorku węgla","parameters":[{"name":"Zakres","range":"(0,312 – 64) mg/m3"},{"name":"Zakres","range":"(0,049 – 10) ppm"},{"name":"Zakres","range":"(0,0050 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość tetrachlorku węgla\nZakres:\nZakres (0,312 – 64) mg/m3\nZakres (0,049 – 10) ppm\nZakres (0,0050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-77/Z-04074.02","norm_bases":["PN-77/Z-04074.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość tetrachlorku węgla\nZakres:\nZakres (0,312 – 64) mg/m3\nZakres (0,049 – 10) ppm\nZakres (0,0050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-77/Z-04074.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc tetrachlorku wegla\nZakres:\nZakres (0,312 – 64) mg/m3\nZakres (0,049 – 10) ppm\nZakres (0,0050 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-77/Z-04074.02","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of carbon tetrachloride","parameters_en":[{"name":"Range","range":"(0,312 – 64) mg/m3"},{"name":"Range","range":"(0,049 – 10) ppm"},{"name":"Range","range":"(0,0050 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of carbon tetrachloride Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-77/Z-04074.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,312 – 64) mg/m3"},{"name":"范围","range":"(0,049 – 10) ppm"},{"name":"范围","range":"(0,0050 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-77/Z-04074.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c6","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość eteru dietylowego","parameters":[{"name":"Zakres","range":"(6,2 – 1200) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość eteru dietylowego\nZakres:\nZakres (6,2 – 1200) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04158.02","norm_bases":["PN-86/Z-04158.02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość eteru dietylowego\nZakres:\nZakres (6,2 – 1200) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04158.02 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc eteru dietylowego\nZakres:\nZakres (6,2 – 1200) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04158.02","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of diethyl ether","parameters_en":[{"name":"Range","range":"(6,2 – 1200) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of diethyl ether Gas chromatography with flame ionization detection (GC-FID) Range Range PN-86/Z-04158.02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 1200) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-86/Z-04158.02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c7","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość butan-2-olu (alkoholu sec-butylowego)","parameters":[{"name":"Zakres","range":"(6,2 – 900) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość butan-2-olu (alkoholu sec-butylowego)\nZakres:\nZakres (6,2 – 900) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04155-4:1996","norm_bases":["PN-Z-04155-4:1996"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość butan-2-olu (alkoholu sec-butylowego)\nZakres:\nZakres (6,2 – 900) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04155-4:1996 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc butan-2-olu (alkoholu sec-butylowego)\nZakres:\nZakres (6,2 – 900) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04155-4:1996","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of butan-2-ol (sec-butyl alcohol)","parameters_en":[{"name":"Range","range":"(6,2 – 900) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of butan-2-ol (sec-butyl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04155-4:1996","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 900) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04155-4:1996","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c8","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość (2-metoksymetyloetoksy) propanolu","parameters":[{"name":"Zakres","range":"(6,2 – 960) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość (2-metoksymetyloetoksy) propanolu\nZakres:\nZakres (6,2 – 960) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04346:2006","norm_bases":["PN-Z-04346:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość (2-metoksymetyloetoksy) propanolu\nZakres:\nZakres (6,2 – 960) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04346:2006 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc (2-metoksymetyloetoksy) propanolu\nZakres:\nZakres (6,2 – 960) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04346:2006","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of (2-methoxymethylethoxy) propanol","parameters_en":[{"name":"Range","range":"(6,2 – 960) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of (2-methoxymethylethoxy) propanol Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04346:2006","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 960) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04346:2006","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203c9","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość dietylobenzenu","parameters":[{"name":"Zakres","range":"(0,062 – 800) mg/m3"},{"name":"Zakres","range":"(0,0010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość dietylobenzenu\nZakres:\nZakres (0,062 – 800) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-8:1999","norm_bases":["PN-Z-04016-8:1999"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość dietylobenzenu\nZakres:\nZakres (0,062 – 800) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-8:1999 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc dietylobenzenu\nZakres:\nZakres (0,062 – 800) mg/m3\nZakres (0,0010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-8:1999","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of diethylbenzene","parameters_en":[{"name":"Range","range":"(0,062 – 800) mg/m3"},{"name":"Range","range":"(0,0010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of diethylbenzene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04016-8:1999","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 800) mg/m3"},{"name":"范围","range":"(0,0010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04016-8:1999","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203ca","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość 2-furylometanolu (alkoholu furfurylowego)","parameters":[{"name":"Zakres","range":"(0,062 – 120) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość 2-furylometanolu (alkoholu furfurylowego)\nZakres:\nZakres (0,062 – 120) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04214-02:1990","norm_bases":["PN-Z-04214-02:1990"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość 2-furylometanolu (alkoholu furfurylowego)\nZakres:\nZakres (0,062 – 120) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04214-02:1990 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc 2-furylometanolu (alkoholu furfurylowego)\nZakres:\nZakres (0,062 – 120) mg/m3\nZakres (0,010 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04214-02:1990","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-furylmethanol (furfuryl alcohol)","parameters_en":[{"name":"Range","range":"(0,062 – 120) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 2-furylmethanol (furfuryl alcohol) Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04214-02:1990","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 120) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04214-02:1990","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203cb","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość octanu 2-butoksyetylu","parameters":[{"name":"Zakres","range":"(0,062 – 600) mg/m3"},{"name":"Zakres","range":"(0,0010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu 2-butoksyetylu\nZakres:\nZakres (0,062 – 600) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04304:2003","norm_bases":["PN-Z-04304:2003"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość octanu 2-butoksyetylu\nZakres:\nZakres (0,062 – 600) mg/m3\nZakres (0,0010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04304:2003 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc octanu 2-butoksyetylu\nZakres:\nZakres (0,062 – 600) mg/m3\nZakres (0,0010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04304:2003","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-butoxyethyl acetate","parameters_en":[{"name":"Range","range":"(0,062 – 600) mg/m3"},{"name":"Range","range":"(0,0010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 2-butoxyethyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04304:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,062 – 600) mg/m3"},{"name":"范围","range":"(0,0010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 乙二醇丁醚醋酸酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04304:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"乙二醇丁醚醋酸酯的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203cc","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość octanu sec-butylu","parameters":[{"name":"Zakres","range":"(6,2 – 1440) mg/m3"},{"name":"Zakres","range":"(0,1 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu sec-butylu\nZakres:\nZakres (6,2 – 1440) mg/m3\nZakres (0,1 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-2:1998","norm_bases":["PN-Z-04119-2:1998"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość octanu sec-butylu\nZakres:\nZakres (6,2 – 1440) mg/m3\nZakres (0,1 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-2:1998 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc octanu sec-butylu\nZakres:\nZakres (6,2 – 1440) mg/m3\nZakres (0,1 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-2:1998","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sec-butyl acetate","parameters_en":[{"name":"Range","range":"(6,2 – 1440) mg/m3"},{"name":"Range","range":"(0,1 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of sec-butyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-2:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 1440) mg/m3"},{"name":"范围","range":"(0,1 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-2:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203cd","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość octanu tert-butylu","parameters":[{"name":"Zakres","range":"(31,2 – 1800) mg/m3"},{"name":"Zakres","range":"(0,50 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu tert-butylu\nZakres:\nZakres (31,2 – 1800) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-3:1998","norm_bases":["PN-Z-04119-3:1998"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość octanu tert-butylu\nZakres:\nZakres (31,2 – 1800) mg/m3\nZakres (0,50 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-3:1998 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc octanu tert-butylu\nZakres:\nZakres (31,2 – 1800) mg/m3\nZakres (0,50 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-3:1998","categories":["environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of tert-butyl acetate","parameters_en":[{"name":"Range","range":"(31,2 – 1800) mg/m3"},{"name":"Range","range":"(0,50 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of tert-butyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-3:1998","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(31,2 – 1800) mg/m3"},{"name":"范围","range":"(0,50 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-3:1998","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203ce","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość octanu 2-metoksy-1-metyloetylu","parameters":[{"name":"Zakres","range":"(6,2 – 1040) mg/m3"},{"name":"Zakres","range":"(0,10 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (6,2 – 1040) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-10:2008/Ap1:2011","norm_bases":["PN-Z-04119-10:2008/Ap1:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (6,2 – 1040) mg/m3\nZakres (0,10 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-10:2008/Ap1:2011 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (6,2 – 1040) mg/m3\nZakres (0,10 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-10:2008/Ap1:2011","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of 2-methoxy-1-methylethyl acetate","parameters_en":[{"name":"Range","range":"(6,2 – 1040) mg/m3"},{"name":"Range","range":"(0,10 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of 2-methoxy-1-methylethyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-10:2008/Ap1:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(6,2 – 1040) mg/m3"},{"name":"范围","range":"(0,10 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 丙二醇甲醚醋酸酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-10:2008/Ap1:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"丙二醇甲醚醋酸酯的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203cf","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość octanu izobutylu","parameters":[{"name":"Zakres","range":"(0,62 – 1440) mg/m3"},{"name":"Zakres","range":"(0,010 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość octanu izobutylu\nZakres:\nZakres (0,62 – 1440) mg/m3\nZakres (0,010 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-11:2008/Ap1:2011","norm_bases":["PN-Z-04119-11:2008/Ap1:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość octanu izobutylu\nZakres:\nZakres (0,62 – 1440) mg/m3\nZakres (0,010 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-11:2008/Ap1:2011 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc octanu izobutylu\nZakres:\nZakres (0,62 – 1440) mg/m3\nZakres (0,010 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-11:2008/Ap1:2011","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of isobutyl acetate","parameters_en":[{"name":"Range","range":"(0,62 – 1440) mg/m3"},{"name":"Range","range":"(0,010 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of isobutyl acetate Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04119-11:2008/Ap1:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 1440) mg/m3"},{"name":"范围","range":"(0,010 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04119-11:2008/Ap1:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203d0","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość disiarczku węgla","parameters":[{"name":"Zakres","range":"(0,62 – 25) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość disiarczku węgla\nZakres:\nZakres (0,62 – 25) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04015-15:1999","norm_bases":["PN-Z-04015-15:1999"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość disiarczku węgla\nZakres:\nZakres (0,62 – 25) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04015-15:1999 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc disiarczku wegla\nZakres:\nZakres (0,62 – 25) mg/m3\nZakres (0,010 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04015-15:1999","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of carbon disulphide","parameters_en":[{"name":"Range","range":"(0,62 – 25) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of carbon disulphide Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04015-15:1999","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 25) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 二硫化碳的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04015-15:1999","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"二硫化碳的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203d1","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość metanolu","parameters":[{"name":"Zakres","range":"(0,156 – 600) mg/m3"},{"name":"Zakres","range":"(0,0050 – 10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość metanolu\nZakres:\nZakres (0,156 – 600) mg/m3\nZakres (0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","norm_bases":["PB-61/CzC/W5-24.01.2018","PB-03/CzG/W8-22.01.2018"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość metanolu\nZakres:\nZakres (0,156 – 600) mg/m3\nZakres (0,0050 – 10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc metanolu\nZakres:\nZakres (0,156 – 600) mg/m3\nZakres (0,0050 – 10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of methanol","parameters_en":[{"name":"Range","range":"(0,156 – 600) mg/m3"},{"name":"Range","range":"(0,0050 – 10) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of methanol Gas chromatography with flame ionization detection (GC-FID) Range Range PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,156 – 600) mg/m3"},{"name":"范围","range":"(0,0050 – 10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203d2","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,312 – 32) mg/m3"},{"name":"Zakres","range":"(0,0050 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość fenolu\nZakres:\nZakres (0,312 – 32) mg/m3\nZakres (0,0050 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04159-10:1989","norm_bases":["PN-Z-04159-10:1989"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość fenolu\nZakres:\nZakres (0,312 – 32) mg/m3\nZakres (0,0050 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04159-10:1989 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc fenolu\nZakres:\nZakres (0,312 – 32) mg/m3\nZakres (0,0050 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04159-10:1989","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration / content","parameters_en":[{"name":"Range","range":"(0,312 – 32) mg/m3"},{"name":"Range","range":"(0,0050 – 1,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Phenol concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04159-10:1989","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,312 – 32) mg/m3"},{"name":"范围","range":"(0,0050 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 苯酚的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04159-10:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203d3","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość nafty","parameters":[{"name":"Zakres","range":"(0,61 – 600) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość nafty\nZakres:\nZakres (0,61 – 600) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04227-02:1992","norm_bases":["PN-Z-04227-02:1992"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość nafty\nZakres:\nZakres (0,61 – 600) mg/m3\nZakres (0,010 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04227-02:1992 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc nafty\nZakres:\nZakres (0,61 – 600) mg/m3\nZakres (0,010 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04227-02:1992","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of kerosene","parameters_en":[{"name":"Range","range":"(0,61 – 600) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of kerosene Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04227-02:1992","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,61 – 600) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04227-02:1992","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203d4","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,0147 – 1,48) mg/m3"},{"name":"Zakres","range":"(0,00047 – 0,050) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,0147 – 1,48) mg/m3\nZakres (0,00047 – 0,050) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","norm_bases":["PB-61/CzC/W5-24.01.2018","PB-03/CzG/W8-22.01.2018"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,0147 – 1,48) mg/m3\nZakres (0,00047 – 0,050) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc formaldehydu\nZakres:\nZakres (0,0147 – 1,48) mg/m3\nZakres (0,00047 – 0,050) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration / content","parameters_en":[{"name":"Range","range":"(0,0147 – 1,48) mg/m3"},{"name":"Range","range":"(0,00047 – 0,050) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Formaldehyde concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,0147 – 1,48) mg/m3"},{"name":"范围","range":"(0,00047 – 0,050) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 甲醛的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PB-61/CzC/W5-24.01.2018 | PB-03/CzG/W8-22.01.2018","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"甲醛的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203d5","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(0,312 – 100) mg/m3"},{"name":"Zakres","range":"(0,125 – 40) ppm"},{"name":"Zakres","range":"(0,0050 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość kwasu octowego\nZakres:\nZakres (0,312 – 100) mg/m3\nZakres (0,125 – 40) ppm\nZakres (0,0050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość kwasu octowego\nZakres:\nZakres (0,312 – 100) mg/m3\nZakres (0,125 – 40) ppm\nZakres (0,0050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04323:2004 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc kwasu octowego\nZakres:\nZakres (0,312 – 100) mg/m3\nZakres (0,125 – 40) ppm\nZakres (0,0050 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04323:2004","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of acetic acid","parameters_en":[{"name":"Range","range":"(0,312 – 100) mg/m3"},{"name":"Range","range":"(0,125 – 40) ppm"},{"name":"Range","range":"(0,0050 – 2,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of acetic acid Gas chromatography with flame ionization detection (GC-FID) Range Range Range PN-Z-04323:2004","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,312 – 100) mg/m3"},{"name":"范围","range":"(0,125 – 40) ppm"},{"name":"范围","range":"(0,0050 – 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 PN-Z-04323:2004","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203d6","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość naftalenu","parameters":[{"name":"Zakres","range":"(0,62 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 1,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość naftalenu\nZakres:\nZakres (0,62 – 100) mg/m3\nZakres (0,010 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04098-3:2005","norm_bases":["PN-Z-04098-3:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość naftalenu\nZakres:\nZakres (0,62 – 100) mg/m3\nZakres (0,010 – 1,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04098-3:2005 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc naftalenu\nZakres:\nZakres (0,62 – 100) mg/m3\nZakres (0,010 – 1,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04098-3:2005","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Naphthalene concentration / content","parameters_en":[{"name":"Range","range":"(0,62 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 1,0) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Naphthalene concentration / content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04098-3:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,62 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 1,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 萘的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04098-3:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品","methodology_zh":"萘的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b203d7","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem","methodology":"Stężenie / zawartość nikotyny","parameters":[{"name":"Zakres","range":"(0,04 – 1,0) mg/m3"},{"name":"Zakres","range":"(0,00048 – 0,016) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość nikotyny\nZakres:\nZakres (0,04 – 1,0) mg/m3\nZakres (0,00048 – 0,016) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2003, nr 4(38), s. 149-155","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2003, nr 4(38), s. 149-155"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane do rurek z sorbentem Stężenie / zawartość nikotyny\nZakres:\nZakres (0,04 – 1,0) mg/m3\nZakres (0,00048 – 0,016) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2003, nr 4(38), s. 149-155 Srodowisko pracy – powietrze – probki powietrza pobrane do rurek z sorbentem Stezenie / zawartosc nikotyny\nZakres:\nZakres (0,04 – 1,0) mg/m3\nZakres (0,00048 – 0,016) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2003, nr 4(38), s. 149-155","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of nicotine","parameters_en":[{"name":"Range","range":"(0,04 – 1,0) mg/m3"},{"name":"Range","range":"(0,00048 – 0,016) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected into sorbent tubes Concentration / content of nicotine Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2003, nr 4(38), s. 149-155","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected into sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,04 – 1,0) mg/m3"},{"name":"范围","range":"(0,00048 – 0,016) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2003, nr 4(38), s. 149-155","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 采集于吸附管的空气样品"},{"_id":"6a83ae76af14b9c0e7b203d8","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry","methodology":"Stężenie / zawartość glicerolu – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,80 – 20) mg/m3"},{"name":"Zakres","range":"(0,14 – 3,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość glicerolu – frakcja wdychalna\nZakres:\nZakres (0,80 – 20) mg/m3\nZakres (0,14 – 3,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04374:2009","norm_bases":["PN-Z-04374:2009"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtry Stężenie / zawartość glicerolu – frakcja wdychalna\nZakres:\nZakres (0,80 – 20) mg/m3\nZakres (0,14 – 3,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04374:2009 Srodowisko pracy – powietrze – probki powietrza pobrane na filtry Stezenie / zawartosc glicerolu – frakcja wdychalna\nZakres:\nZakres (0,80 – 20) mg/m3\nZakres (0,14 – 3,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04374:2009","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of glycerol – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,80 – 20) mg/m3"},{"name":"Range","range":"(0,14 – 3,6) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on filters Concentration / content of glycerol – inhalable fraction Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04374:2009","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,80 – 20) mg/m3"},{"name":"范围","range":"(0,14 – 3,6) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04374:2009","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品"},{"_id":"6a83ae76af14b9c0e7b203d9","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtr i do rurek z sorbentem","methodology":"Stężenie / zawartość propano-1,2-diolu – pary i frakcja wdychalna","parameters":[{"name":"Zakres","range":"(8,0 – 200) mg/m3"},{"name":"Zakres","range":"(1,4 – 36) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość propano-1,2-diolu – pary i frakcja wdychalna\nZakres:\nZakres (8,0 – 200) mg/m3\nZakres (1,4 – 36) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92), s. 173-188","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92), s. 173-188"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze – próbki powietrza pobrane na filtr i do rurek z sorbentem Stężenie / zawartość propano-1,2-diolu – pary i frakcja wdychalna\nZakres:\nZakres (8,0 – 200) mg/m3\nZakres (1,4 – 36) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92), s. 173-188 Srodowisko pracy – powietrze – probki powietrza pobrane na filtr i do rurek z sorbentem Stezenie / zawartosc propano-1,2-diolu – pary i frakcja wdychalna\nZakres:\nZakres (8,0 – 200) mg/m3\nZakres (1,4 – 36) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2(92), s. 173-188","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of propane-1,2-diol – vapours and inhalable fraction","parameters_en":[{"name":"Range","range":"(8,0 – 200) mg/m3"},{"name":"Range","range":"(1,4 – 36) mg w próbce"}],"search_en":"Workplace environment – air – air samples collected on a filter and into sorbent tubes Concentration / content of propane-1,2-diol – vapours and inhalable fraction Gas chromatography with flame ionization detection (GC-FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92), s. 173-188","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment – air – air samples collected on a filter and into sorbent tubes","parameters_zh":[{"name":"范围","range":"(8,0 – 200) mg/m3"},{"name":"范围","range":"(1,4 – 36) mg w próbce"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2(92), s. 173-188","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a83ae76af14b9c0e7b203da","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze atmosferyczne","methodology":"Pobieranie próbek pyłu zawieszonego, PM 2,5 i PM 10","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu zawieszonego, PM 2,5 i PM 10","reference":"PN-EN 12341:2024-01","norm_bases":["PN-EN 12341:2024-01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – powietrze atmosferyczne Pobieranie próbek pyłu zawieszonego, PM 2,5 i PM 10 PN-EN 12341:2024-01 Srodowisko ogolne – powietrze atmosferyczne Pobieranie probek pylu zawieszonego, PM 2,5 i PM 10 PN-EN 12341:2024-01","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling of suspended particulate matter, PM 2,5 and PM 10","search_en":"General environment – ambient air Sampling of suspended particulate matter, PM 2,5 and PM 10 PN-EN 12341:2024-01","test_object_en":"General environment – ambient air","search_zh":"一般环境 － 大气空气 PN-EN 12341:2024-01","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83ae76af14b9c0e7b203db","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze atmosferyczne","methodology":"Stężenie pyłu zawieszonego PM 2,5","parameters":[{"name":"Zakres","range":"(1,0-300,0) μg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu zawieszonego PM 2,5\nZakres (1,0-300,0) μg/m3\nMetoda grawimetryczna","reference":"PN-EN 12341:2024-01","norm_bases":["PN-EN 12341:2024-01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – powietrze atmosferyczne Stężenie pyłu zawieszonego PM 2,5\nZakres (1,0-300,0) μg/m3\nMetoda grawimetryczna PN-EN 12341:2024-01 Srodowisko ogolne – powietrze atmosferyczne Stezenie pylu zawieszonego PM 2,5\nZakres (1,0-300,0) μg/m3\nMetoda grawimetryczna PN-EN 12341:2024-01","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of suspended particulate matter PM 2,5","parameters_en":[{"name":"Range","range":"(1,0-300,0) μg/m3"}],"search_en":"General environment – ambient air Concentration of suspended particulate matter PM 2,5 Gravimetric method Range PN-EN 12341:2024-01","technique_en":"Gravimetric method","test_object_en":"General environment – ambient air","parameters_zh":[{"name":"范围","range":"(1,0-300,0) μg/m3"}],"search_zh":"一般环境 － 大气空气 重量法 范围 PN-EN 12341:2024-01","technique_zh":"重量法","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83ae76af14b9c0e7b203dc","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne – powietrze atmosferyczne","methodology":"Stężenie pyłu zawieszonego PM 10","parameters":[{"name":"Zakres","range":"(1,0-300,0) μg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu zawieszonego PM 10\nZakres (1,0-300,0) μg/m3\nMetoda grawimetryczna","reference":"PN-EN 12341:2024-01","norm_bases":["PN-EN 12341:2024-01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – powietrze atmosferyczne Stężenie pyłu zawieszonego PM 10\nZakres (1,0-300,0) μg/m3\nMetoda grawimetryczna PN-EN 12341:2024-01 Srodowisko ogolne – powietrze atmosferyczne Stezenie pylu zawieszonego PM 10\nZakres (1,0-300,0) μg/m3\nMetoda grawimetryczna PN-EN 12341:2024-01","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of suspended particulate matter PM 10","parameters_en":[{"name":"Range","range":"(1,0-300,0) μg/m3"}],"search_en":"General environment – ambient air Concentration of suspended particulate matter PM 10 Gravimetric method Range PN-EN 12341:2024-01","technique_en":"Gravimetric method","test_object_en":"General environment – ambient air","parameters_zh":[{"name":"范围","range":"(1,0-300,0) μg/m3"}],"search_zh":"一般环境 － 大气空气 重量法 范围 PN-EN 12341:2024-01","technique_zh":"重量法","test_object_zh":"一般环境 － 大气空气"},{"_id":"6a83ae76af14b9c0e7b203dd","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40,0 – 137,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (40,0 – 137,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011+Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011+Ap1:2017-09"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Równoważny poziom dźwięku A\nZakres (40,0 – 137,0) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3746:2011+Ap1:2017-09 Maszyny i urzadzenia – halas Rownowazny poziom dzwieku A\nZakres (40,0 – 137,0) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3746:2011+Ap1:2017-09","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(40,0 – 137,0) dB"}],"search_en":"Machinery and equipment – noise A-weighted equivalent sound pressure level Direct measurement method Range PN-EN ISO 3746:2011+Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(40,0 – 137,0) dB"}],"search_zh":"机器与设备 – 噪声 A 计权等效声级 直接测量法 范围 PN-EN ISO 3746:2011+Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声"},{"_id":"6a83ae76af14b9c0e7b203de","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3746:2011+Ap1:2017-09","norm_bases":["PN-EN ISO 3746:2011+Ap1:2017-09"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3746:2011+Ap1:2017-09 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3746:2011+Ap1:2017-09","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3746:2011+Ap1:2017-09","test_object_en":"Machinery and equipment – noise","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3746:2011+Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a83ae76af14b9c0e7b203df","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od linii elektroenergetycznych wysokiego napięcia","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01339:2000 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","norm_bases":["PN-N-01339:2000 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od linii elektroenergetycznych wysokiego napięcia Równoważny poziom dźwięku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01339:2000 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706) Srodowisko ogolne – halas pochodzacy od linii elektroenergetycznych wysokiego napiecia Rownowazny poziom dzwieku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezposrednia PN-N-01339:2000 Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25,0 – 136,0) dB"}],"search_en":"General environment – noise from high-voltage power lines A-weighted equivalent sound pressure level Direct measurement method Range PN-N-01339:2000 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment – noise from high-voltage power lines","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25,0 – 136,0) dB"}],"search_zh":"一般环境 － 来自高压输电线路的噪声 A 计权等效声级 直接测量法 范围 PN-N-01339:2000 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 － 来自高压输电线路的噪声"},{"_id":"6a83ae76af14b9c0e7b203e0","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i tramwajowych","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(28,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (28,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A\nZakres (28,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych i tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A\nZakres (28,0 – 136,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(28,0 – 136,0) dB"}],"search_en":"General environment – noise from roads, railway and tramway lines A-weighted equivalent sound level A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","technique_en":"Direct measurement method","test_object_en":"General environment – noise from roads, railway and tramway lines","parameters_zh":[{"name":"范围","range":"(28,0 – 136,0) dB"}],"search_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声 A 计权等效声级 A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","technique_zh":"直接测量法","methodology_zh":"A 计权等效声级 A 计权声暴露级","test_object_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声"},{"_id":"6a83ae76af14b9c0e7b203e1","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LaeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LaeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od dróg, linii kolejowych i tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LaeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) Srodowisko ogolne – halas pochodzacy od drog, linii kolejowych i tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LaeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LaeqN (calculated)","search_en":"General environment – noise from roads, railway and tramway lines A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LaeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","test_object_en":"General environment – noise from roads, railway and tramway lines","search_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697)","test_object_zh":"一般环境 － 来自道路、铁路线与有轨电车线路的噪声"},{"_id":"6a83ae76af14b9c0e7b203e2","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706) Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25,0 – 136,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25,0 – 136,0) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25,0 – 136,0) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83ae76af14b9c0e7b203e3","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LaeqN (z obliczeń)","parameters":[],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LaeqN (z obliczeń)\nMetoda obliczeniowa","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LaeqN (z obliczeń)\nMetoda obliczeniowa Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706) Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LaeqN (z obliczen)\nMetoda obliczeniowa Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LaeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD and LaeqN (calculated) Calculation method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","technique_en":"Calculation method","test_object_en":"General environment - noise from installations, equipment and industrial plants","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 计算法 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (Dz. U. z 2023 r., poz. 1706)","technique_zh":"计算法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83ae76af14b9c0e7b203e4","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24,0 – 136,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (24,0 – 136,0) dB\nMetoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (24,0 – 136,0) dB\nMetoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24,0 – 136,0) dB"}],"search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-87/B-02156","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24,0 – 136,0) dB"}],"search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-87/B-02156","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83ae76af14b9c0e7b203e5","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen) PN-87/B-02156","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","search_en":"Rooms in residential, collective residence and public utility buildings – noise A-weighted equivalent sound level for reference time T (calculated) PN-87/B-02156","test_object_en":"Rooms in residential, collective residence and public utility buildings – noise","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声 参考时间 T 内的 A 计权等效声级（计算得出） PN-87/B-02156","test_object_zh":"住宅、集体居住建筑与公共建筑内的房间 – 噪声"},{"_id":"6a83ae76af14b9c0e7b203e6","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego","methodology":"Równoważny poziom dźwięku A Maksymalny pozom dźwięku A","parameters":[{"name":"Zakres","range":"(24,0 – 115,0) dB"},{"name":"Równoważny poziom dźwięku C Maksymalny pozom dźwięku C"},{"name":"Zakres","range":"(40,0 – 135,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny pozom dźwięku A\nZakres:\nZakres (24,0 – 115,0) dB\nRównoważny poziom dźwięku C Maksymalny pozom dźwięku C\nZakres (40,0 – 135,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010","norm_bases":["PN-EN ISO 10052:2007","PN-EN ISO 10052:2007/A1:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – hałas pochodzący od urządzeń wyposażenia technicznego Równoważny poziom dźwięku A Maksymalny pozom dźwięku A\nZakres:\nZakres (24,0 – 115,0) dB\nRównoważny poziom dźwięku C Maksymalny pozom dźwięku C\nZakres (40,0 – 135,0) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – halas pochodzacy od urzadzen wyposazenia technicznego Rownowazny poziom dzwieku A Maksymalny pozom dzwieku A\nZakres:\nZakres (24,0 – 115,0) dB\nRownowazny poziom dzwieku C Maksymalny pozom dzwieku C\nZakres (40,0 – 135,0) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level","parameters_en":[{"name":"Range","range":"(24,0 – 115,0) dB"},{"name":"Equivalent C-weighted sound level Maximum C-weighted sound level"},{"name":"Range","range":"(40,0 – 135,0) dB"}],"search_en":"Rooms in residential, collective residence and public buildings – noise originating from building service equipment A-weighted equivalent sound level A-weighted maximum sound level Direct measurement method Range Equivalent C-weighted sound level Maximum C-weighted sound level Range PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010","technique_en":"Direct measurement method","test_object_en":"Rooms in residential, collective residence and public buildings – noise originating from building service equipment","parameters_zh":[{"name":"范围","range":"(24,0 – 115,0) dB"},{"name":"Równoważny poziom dźwięku C Maksymalny pozom dźwięku C"},{"name":"范围","range":"(40,0 – 135,0) dB"}],"search_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生的噪声 直接测量法 范围 范围 PN-EN ISO 10052:2007 | PN-EN ISO 10052:2007/A1:2010","technique_zh":"直接测量法","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 由技术设备装置产生的噪声"},{"_id":"6a83ae76af14b9c0e7b203e7","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko – pomieszczenia przeznaczone do pracy i na pobyt ludzi","methodology":"Strumień powietrza na elementach końcowych","parameters":[{"name":"Zakres","range":"(0,4 – 30) m/s"}],"technique":"Metoda anemometryczna","techniques":["Metoda anemometryczna"],"computed":[],"activity":"Strumień powietrza na elementach końcowych\nZakres (0,4 – 30) m/s\nMetoda anemometryczna","reference":"PN-EN 12599:2013-04","norm_bases":["PN-EN 12599:2013-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko – pomieszczenia przeznaczone do pracy i na pobyt ludzi Strumień powietrza na elementach końcowych\nZakres (0,4 – 30) m/s\nMetoda anemometryczna PN-EN 12599:2013-04 Srodowisko – pomieszczenia przeznaczone do pracy i na pobyt ludzi Strumien powietrza na elementach koncowych\nZakres (0,4 – 30) m/s\nMetoda anemometryczna PN-EN 12599:2013-04","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air flow at terminal units","parameters_en":[{"name":"Range","range":"(0,4 – 30) m/s"}],"search_en":"Environment – rooms intended for work and human occupancy Air flow at terminal units Anemometric method Range PN-EN 12599:2013-04","technique_en":"Anemometric method","test_object_en":"Environment – rooms intended for work and human occupancy","parameters_zh":[{"name":"范围","range":"(0,4 – 30) m/s"}],"search_zh":"环境 － 供工作与人员停留的房间 风速仪法 范围 PN-EN 12599:2013-04","technique_zh":"风速仪法","test_object_zh":"环境 － 供工作与人员停留的房间"},{"_id":"6a83ae76af14b9c0e7b203e8","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko – pomieszczenia przeznaczone do pracy i na pobyt ludzi","methodology":"Krotność wymiany powietrza (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Krotność wymiany powietrza (z obliczeń)","reference":"PN-EN 12599:2013-04","norm_bases":["PN-EN 12599:2013-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko – pomieszczenia przeznaczone do pracy i na pobyt ludzi Krotność wymiany powietrza (z obliczeń) PN-EN 12599:2013-04 Srodowisko – pomieszczenia przeznaczone do pracy i na pobyt ludzi Krotnosc wymiany powietrza (z obliczen) PN-EN 12599:2013-04","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air change rate (calculated)","search_en":"Environment – rooms intended for work and human occupancy Air change rate (calculated) PN-EN 12599:2013-04","test_object_en":"Environment – rooms intended for work and human occupancy","search_zh":"环境 － 供工作与人员停留的房间 PN-EN 12599:2013-04","test_object_zh":"环境 － 供工作与人员停留的房间"},{"_id":"6a83ae76af14b9c0e7b203e9","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 – 136,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(35,0 – 140,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 – 136,0) dB\nSzczytowy poziom dźwięku C\nZakres (35,0 – 140,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011","PN-EN ISO 9612:2025-11"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 – 136,0) dB\nSzczytowy poziom dźwięku C\nZakres (35,0 – 140,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25,0 – 136,0) dB\nSzczytowy poziom dzwieku C\nZakres (35,0 – 140,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25,0 – 136,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(35,0 – 140,0) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25,0 – 136,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(35,0 – 140,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83ae76af14b9c0e7b203ea","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011","PN-EN ISO 9612:2025-11"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","categories":["environment"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 | PN-EN ISO 9612:2025-11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83ae76af14b9c0e7b203eb","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,053 – 316) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,053 – 316) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,053 – 316) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,053 – 316) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,053 – 316) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,053 – 316) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a83ae76af14b9c0e7b203ec","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）"},{"_id":"6a83ae76af14b9c0e7b203ed","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,018 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,018 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,018 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,018 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,018 – 100) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,018 – 100) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a83ae76af14b9c0e7b203ee","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyśpieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyśpieszenia drgań, dominującego wśród przyspieszeń drgań wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4awx, 1,4awy, awz), (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a83ae76af14b9c0e7b203ef","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 1000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 1000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 1000) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5 Srodowisko pracy – oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 1000) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","categories":["environment"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 1000) lx"}],"search_en":"Workplace environment – emergency lighting Illuminance Direct measurement method Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment – emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 1000) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83ae76af14b9c0e7b203f0","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5 Srodowisko pracy – oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","categories":["environment"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment – emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_en":"Workplace environment – emergency lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83ae76af14b9c0e7b203f1","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5 Srodowisko pracy – oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","categories":["environment"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment – emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_en":"Workplace environment – emergency lighting","search_zh":"工作场所环境 — 应急照明 高风险区照度均匀度（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"高风险区照度均匀度（计算值）"},{"_id":"6a83ae76af14b9c0e7b203f2","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Czas załączania oświetlenia","parameters":[{"name":"Zakres","range":"(1 – 80) s"}],"technique":null,"techniques":[],"computed":[],"activity":"Czas załączania oświetlenia\nZakres (1 – 80) s","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Czas załączania oświetlenia\nZakres (1 – 80) s PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5 Srodowisko pracy – oswietlenie awaryjne Czas zalaczania oswietlenia\nZakres (1 – 80) s PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Lighting switch-on time","parameters_en":[{"name":"Range","range":"(1 – 80) s"}],"search_en":"Workplace environment – emergency lighting Lighting switch-on time Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_en":"Workplace environment – emergency lighting","parameters_zh":[{"name":"范围","range":"(1 – 80) s"}],"search_zh":"工作场所环境 — 应急照明 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a83ae76af14b9c0e7b203f3","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie awaryjne","methodology":"Minimalny czas stosowania oświetlenia","parameters":[{"name":"Zakres","range":"(1 – 3600) s"}],"technique":null,"techniques":[],"computed":[],"activity":"Minimalny czas stosowania oświetlenia\nZakres (1 – 3600) s","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie awaryjne Minimalny czas stosowania oświetlenia\nZakres (1 – 3600) s PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5 Srodowisko pracy – oswietlenie awaryjne Minimalny czas stosowania oswietlenia\nZakres (1 – 3600) s PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","categories":["environment"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Minimum duration of lighting operation","parameters_en":[{"name":"Range","range":"(1 – 3600) s"}],"search_en":"Workplace environment – emergency lighting Minimum duration of lighting operation Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_en":"Workplace environment – emergency lighting","parameters_zh":[{"name":"范围","range":"(1 – 3600) s"}],"search_zh":"工作场所环境 — 应急照明 照明的最短使用时间 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.3.3, 4.3.4, 4.4.3, 4.4.4 i 5","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"照明的最短使用时间"},{"_id":"6a83ae76af14b9c0e7b203f4","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 10000) lx"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 10000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83ae76af14b9c0e7b203f5","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83ae76af14b9c0e7b203f6","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – wyrobiska podziemne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(1 – 1000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (1 – 1000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-G-02600:1996","norm_bases":["PN-G-02600:1996"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – wyrobiska podziemne Natężenie oświetlenia\nZakres (1 – 1000) lx\nMetoda pomiarowa bezpośrednia PN-G-02600:1996 Srodowisko pracy – oswietlenie elektryczne – zaklady gornicze – wyrobiska podziemne Natezenie oswietlenia\nZakres (1 – 1000) lx\nMetoda pomiarowa bezposrednia PN-G-02600:1996","categories":["environment"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(1 – 1000) lx"}],"search_en":"Workplace environment – electric lighting – mining plants – underground workings Illuminance Direct measurement method Range PN-G-02600:1996","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electric lighting – mining plants – underground workings","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(1 – 1000) lx"}],"search_zh":"照度 直接测量法 范围 PN-G-02600:1996","technique_zh":"直接测量法"},{"_id":"6a83ae76af14b9c0e7b203f7","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – wyrobiska podziemne","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-G-02600:1996","norm_bases":["PN-G-02600:1996"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – wyrobiska podziemne Równomierność oświetlenia (z obliczeń) PN-G-02600:1996 Srodowisko pracy – oswietlenie elektryczne – zaklady gornicze – wyrobiska podziemne Rownomiernosc oswietlenia (z obliczen) PN-G-02600:1996","categories":["environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – electric lighting – mining plants – underground workings Illuminance uniformity (calculated) PN-G-02600:1996","test_object_en":"Workplace environment – electric lighting – mining plants – underground workings","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值） PN-G-02600:1996"},{"_id":"6a83ae76af14b9c0e7b203f8","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – powierzchnia","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(1 – 1000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (1 – 1000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-G-02601:1999","norm_bases":["PN-G-02601:1999"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – powierzchnia Natężenie oświetlenia\nZakres (1 – 1000) lx\nMetoda pomiarowa bezpośrednia PN-G-02601:1999 Srodowisko pracy – oswietlenie elektryczne – zaklady gornicze – powierzchnia Natezenie oswietlenia\nZakres (1 – 1000) lx\nMetoda pomiarowa bezposrednia PN-G-02601:1999","categories":["environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(1 – 1000) lx"}],"search_en":"Workplace environment – electric lighting – mining plants – surface Illuminance Direct measurement method Range PN-G-02601:1999","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electric lighting – mining plants – surface","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(1 – 1000) lx"}],"search_zh":"照度 直接测量法 范围 PN-G-02601:1999","technique_zh":"直接测量法"},{"_id":"6a83ae76af14b9c0e7b203f9","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – powierzchnia","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-G-02601:1999","norm_bases":["PN-G-02601:1999"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne – zakłady górnicze – powierzchnia Równomierność oświetlenia (z obliczeń) PN-G-02601:1999 Srodowisko pracy – oswietlenie elektryczne – zaklady gornicze – powierzchnia Rownomiernosc oswietlenia (z obliczen) PN-G-02601:1999","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – electric lighting – mining plants – surface Illuminance uniformity (calculated) PN-G-02601:1999","test_object_en":"Workplace environment – electric lighting – mining plants – surface","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值） PN-G-02601:1999"},{"_id":"6a83ae76af14b9c0e7b203fa","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(0 – 60) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 – 60) dm3/min"}],"technique":"Metoda bezpośrednia","techniques":["Metoda bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (0 – 60) °C\nPrzepływ powietrza\nZakres (10 – 60) dm3/min\nMetoda bezpośrednia","reference":"PB-41/W4-31.01.2018","norm_bases":["PB-41/W4-31.01.2018"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 – 60) °C\nPrzepływ powietrza\nZakres (10 – 60) dm3/min\nMetoda bezpośrednia PB-41/W4-31.01.2018 Srodowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (0 – 60) °C\nPrzeplyw powietrza\nZakres (10 – 60) dm3/min\nMetoda bezposrednia PB-41/W4-31.01.2018","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(0 – 60) °C"},{"name":"Air flow"},{"name":"Range","range":"(10 – 60) dm3/min"}],"search_en":"Workplace environment – energy expenditure Air temperature Direct method Range Air flow Range PB-41/W4-31.01.2018","technique_en":"Direct method","test_object_en":"Workplace environment – energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(0 – 60) °C"},{"name":"空气流量"},{"name":"范围","range":"(10 – 60) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接法 范围 空气流量 范围 PB-41/W4-31.01.2018","technique_zh":"直接法","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a83ae76af14b9c0e7b203fb","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"PB-41/W4-31.01.2018","norm_bases":["PB-41/W4-31.01.2018"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczeń) PB-41/W4-31.01.2018 Srodowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczen) PB-41/W4-31.01.2018","categories":["environment"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment – energy expenditure Energy expenditure (calculated) PB-41/W4-31.01.2018","test_object_en":"Workplace environment – energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） PB-41/W4-31.01.2018","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a83ae76af14b9c0e7b203fc","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 – 60) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 – 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15 – 60) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (15 – 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15 – 60) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15 – 60) °C"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 – 60) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(15 – 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83ae76af14b9c0e7b203fd","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a83ae76af14b9c0e7b203fe","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 15) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 15) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 15) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 15) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a83ae76af14b9c0e7b203ff","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik twc, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik twc, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik twc, Wskaźnik IREQmin, Wskaźnik IREQneutral (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik twc, Wskaznik IREQmin, Wskaznik IREQneutral (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"twc index, IREQmin index, IREQneutral index (calculated)","search_en":"Workplace environment – cold microclimate twc index, IREQmin index, IREQneutral index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment – cold microclimate","search_zh":"工作场所环境 — 低温微气候 twc 指数、IREQmin 指数、IREQneutral 指数（由计算得出） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"twc 指数、IREQmin 指数、IREQneutral 指数（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20400","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN-ISO 7730:2006","PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 1,0) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83ae76af14b9c0e7b20401","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN-ISO 7730:2006","PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN-ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a83ae76af14b9c0e7b20402","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – pola elektromagnetyczne","methodology":"Natężenie pola elektrycznego w paśmie częstotliwości 10 Hz – 400 kHz","parameters":[{"name":"Zakres","range":"1V/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w paśmie częstotliwości 10 Hz – 400 kHz\nZakres 1V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – pola elektromagnetyczne Natężenie pola elektrycznego w paśmie częstotliwości 10 Hz – 400 kHz\nZakres 1V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy – pola elektromagnetyczne Natezenie pola elektrycznego w pasmie czestotliwosci 10 Hz – 400 kHz\nZakres 1V/m – 50 kV/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency band 10 Hz – 400 kHz","parameters_en":[{"name":"Range","range":"1V/m – 50 kV/m"}],"search_en":"Workplace environment – electromagnetic fields Electric field strength in the frequency band 10 Hz – 400 kHz Direct measurement method Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic fields","parameters_zh":[{"name":"范围","range":"1V/m – 50 kV/m"}],"search_zh":"直接测量法 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法"},{"_id":"6a83ae76af14b9c0e7b20403","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – pola elektromagnetyczne","methodology":"Indukcja magnetyczna: 0 Hz","parameters":[{"name":"Zakres","range":"0,5 mT – 1 T"},{"name":"Indukcja magnetyczna w paśmie częstotliwości: 0,5 Hz – 400 Hz"},{"name":"Zakres","range":"0,5 mT – 46 mT"},{"name":"Indukcja magnetyczna w paśmie częstotliwości: 10 Hz – 400 kHz"},{"name":"Zakres","range":"200 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna: 0 Hz\nZakres:\nZakres 0,5 mT – 1 T\nIndukcja magnetyczna w paśmie częstotliwości: 0,5 Hz – 400 Hz\nZakres 0,5 mT – 46 mT\nIndukcja magnetyczna w paśmie częstotliwości: 10 Hz – 400 kHz\nZakres 200 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – pola elektromagnetyczne Indukcja magnetyczna: 0 Hz\nZakres:\nZakres 0,5 mT – 1 T\nIndukcja magnetyczna w paśmie częstotliwości: 0,5 Hz – 400 Hz\nZakres 0,5 mT – 46 mT\nIndukcja magnetyczna w paśmie częstotliwości: 10 Hz – 400 kHz\nZakres 200 nT – 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy – pola elektromagnetyczne Indukcja magnetyczna: 0 Hz\nZakres:\nZakres 0,5 mT – 1 T\nIndukcja magnetyczna w pasmie czestotliwosci: 0,5 Hz – 400 Hz\nZakres 0,5 mT – 46 mT\nIndukcja magnetyczna w pasmie czestotliwosci: 10 Hz – 400 kHz\nZakres 200 nT – 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density: 0 Hz","parameters_en":[{"name":"Range","range":"0,5 mT – 1 T"},{"name":"Magnetic flux density in the frequency band: 0,5 Hz – 400 Hz"},{"name":"Range","range":"0,5 mT – 46 mT"},{"name":"Magnetic flux density in the frequency band: 10 Hz – 400 kHz"},{"name":"Range","range":"200 nT – 19 mT"}],"search_en":"Workplace environment – electromagnetic fields Magnetic flux density: 0 Hz Direct measurement method Range Magnetic flux density in the frequency band: 0,5 Hz – 400 Hz Range Magnetic flux density in the frequency band: 10 Hz – 400 kHz Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic fields","parameters_zh":[{"name":"范围","range":"0,5 mT – 1 T"},{"name":"Indukcja magnetyczna w paśmie częstotliwości: 0,5 Hz – 400 Hz"},{"name":"范围","range":"0,5 mT – 46 mT"},{"name":"Indukcja magnetyczna w paśmie częstotliwości: 10 Hz – 400 kHz"},{"name":"范围","range":"200 nT – 19 mT"}],"search_zh":"直接测量法 范围 范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法"},{"_id":"6a83ae76af14b9c0e7b20404","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości 45 – 55 Hz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 45 – 55 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 45 – 55 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 45 – 55 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 - 150","categories":["environment"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range 45 – 55 Hz"},{"name":"Range","range":"1 V/m – 50 kV/m"}],"search_en":"Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range 45 – 55 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości 45 – 55 Hz"},{"name":"范围","range":"1 V/m – 50 kV/m"}],"search_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场 电场强度： 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场"},{"_id":"6a83ae76af14b9c0e7b20405","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna","parameters":[{"name":"w zakresie częstotliwości 45 – 55 Hz"},{"name":"Zakres","range":"200nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna\nZakres:\nw zakresie częstotliwości 45 – 55 Hz\nZakres 200nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna\nZakres:\nw zakresie częstotliwości 45 – 55 Hz\nZakres 200nT – 19 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150 Srodowisko pracy - pole elektromagnetyczne pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna\nZakres:\nw zakresie czestotliwosci 45 – 55 Hz\nZakres 200nT – 19 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 - 150","categories":["environment"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density","parameters_en":[{"name":"in the frequency range 45 – 55 Hz"},{"name":"Range","range":"200nT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry Magnetic flux density Direct measurement method in the frequency range 45 – 55 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"w zakresie częstotliwości 45 – 55 Hz"},{"name":"范围","range":"200nT – 19 mT"}],"search_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场 磁感应强度 直接测量法 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 - 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 来自电力系统与电力行业交流供电装置的电磁场","methodology_zh":"磁感应强度"},{"_id":"6a83ae76af14b9c0e7b20406","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna","parameters":[{"name":"w zakresie częstotliwości 20 – 50 Hz"},{"name":"Zakres","range":"200nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna\nZakres:\nw zakresie częstotliwości 20 – 50 Hz\nZakres 200nT – 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna\nZakres:\nw zakresie częstotliwości 20 – 50 Hz\nZakres 200nT – 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna\nZakres:\nw zakresie czestotliwosci 20 – 50 Hz\nZakres 200nT – 19 mT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density","parameters_en":[{"name":"in the frequency range 20 – 50 Hz"},{"name":"Range","range":"200nT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density Direct measurement method (simplified) in the frequency range 20 – 50 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","parameters_zh":[{"name":"w zakresie częstotliwości 20 – 50 Hz"},{"name":"范围","range":"200nT – 19 mT"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 磁感应强度 直接测量法（简化） 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场","technique_zh":"直接测量法（简化）","methodology_zh":"磁感应强度"},{"_id":"6a83ae76af14b9c0e7b20407","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia dla UV w zakresie spektralnym 180 – 400 nm","parameters":[{"name":"Zakres","range":"(10-6 – 39,9) W/m2"}],"technique":"Metoda pomiaru bezpośredniego (metoda A)","techniques":["Metoda pomiaru bezpośredniego (metoda A)"],"computed":[],"activity":"Skuteczne natężenie napromienienia dla UV w zakresie spektralnym 180 – 400 nm\nZakres (10-6 – 39,9) W/m2\nMetoda pomiaru bezpośredniego (metoda A)","reference":"PN-EN 14255-1:2010 | PN-T-06589:2002","norm_bases":["PN-EN 14255-1:2010","PN-T-06589:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia dla UV w zakresie spektralnym 180 – 400 nm\nZakres (10-6 – 39,9) W/m2\nMetoda pomiaru bezpośredniego (metoda A) PN-EN 14255-1:2010 | PN-T-06589:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia dla UV w zakresie spektralnym 180 – 400 nm\nZakres (10-6 – 39,9) W/m2\nMetoda pomiaru bezposredniego (metoda A) PN-EN 14255-1:2010 | PN-T-06589:2002","categories":["environment"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance for UV in the spectral range 180 – 400 nm","parameters_en":[{"name":"Range","range":"(10-6 – 39,9) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Effective irradiance for UV in the spectral range 180 – 400 nm Direct measurement method (method A) Range PN-EN 14255-1:2010 | PN-T-06589:2002","technique_en":"Direct measurement method (method A)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-6 – 39,9) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 A） 范围 PN-EN 14255-1:2010 | PN-T-06589:2002","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 A）"},{"_id":"6a83ae76af14b9c0e7b20408","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne napromienienie dla UV w zakresie spektralnym 180 – 400 nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczne napromienienie dla UV w zakresie spektralnym 180 – 400 nm (z obliczeń)","reference":"PN-EN 14255-1:2010 | PN-T-06589:2002","norm_bases":["PN-EN 14255-1:2010","PN-T-06589:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne napromienienie dla UV w zakresie spektralnym 180 – 400 nm (z obliczeń) PN-EN 14255-1:2010 | PN-T-06589:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne napromienienie dla UV w zakresie spektralnym 180 – 400 nm (z obliczen) PN-EN 14255-1:2010 | PN-T-06589:2002","categories":["environment"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiant exposure for UV in the spectral range 180 – 400 nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Effective radiant exposure for UV in the spectral range 180 – 400 nm (calculated) PN-EN 14255-1:2010 | PN-T-06589:2002","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-1:2010 | PN-T-06589:2002","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b20409","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia dla UVA w zakresie spektralnym 315 – 400 nm","parameters":[{"name":"Zakres","range":"(10-3 – 3990) W/m2"}],"technique":"Metoda pomiaru bezpośredniego (metoda M)","techniques":["Metoda pomiaru bezpośredniego (metoda M)"],"computed":[],"activity":"Natężenie napromienienia dla UVA w zakresie spektralnym 315 – 400 nm\nZakres (10-3 – 3990) W/m2\nMetoda pomiaru bezpośredniego (metoda M)","reference":"PN-EN 14255-1:2010 | PN-T-06589:2002","norm_bases":["PN-EN 14255-1:2010","PN-T-06589:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia dla UVA w zakresie spektralnym 315 – 400 nm\nZakres (10-3 – 3990) W/m2\nMetoda pomiaru bezpośredniego (metoda M) PN-EN 14255-1:2010 | PN-T-06589:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia dla UVA w zakresie spektralnym 315 – 400 nm\nZakres (10-3 – 3990) W/m2\nMetoda pomiaru bezposredniego (metoda M) PN-EN 14255-1:2010 | PN-T-06589:2002","categories":["environment"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance for UVA in the spectral range 315 – 400 nm","parameters_en":[{"name":"Range","range":"(10-3 – 3990) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Irradiance for UVA in the spectral range 315 – 400 nm Direct measurement method (method M) Range PN-EN 14255-1:2010 | PN-T-06589:2002","technique_en":"Direct measurement method (method M)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-3 – 3990) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 M） 范围 PN-EN 14255-1:2010 | PN-T-06589:2002","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 M）"},{"_id":"6a83ae76af14b9c0e7b2040a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie dla UVA w zakresie spektralnym: 315 - 400 nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie dla UVA w zakresie spektralnym: 315 - 400 nm (z obliczeń)","reference":"PN-EN 14255-1:2010 | PN-T-06589:2002","norm_bases":["PN-EN 14255-1:2010","PN-T-06589:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie dla UVA w zakresie spektralnym: 315 - 400 nm (z obliczeń) PN-EN 14255-1:2010 | PN-T-06589:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie dla UVA w zakresie spektralnym: 315 - 400 nm (z obliczen) PN-EN 14255-1:2010 | PN-T-06589:2002","categories":["environment"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure for UVA in the spectral range: 315 - 400 nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Radiant exposure for UVA in the spectral range: 315 - 400 nm (calculated) PN-EN 14255-1:2010 | PN-T-06589:2002","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-1:2010 | PN-T-06589:2002","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b2040b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia dla VIS w zakresie spektralnym 300 – 700 nm","parameters":[{"name":"Zakres","range":"(10-6 – 399) W/m2"}],"technique":"Metoda pomiaru bezpośredniego (metoda O)","techniques":["Metoda pomiaru bezpośredniego (metoda O)"],"computed":[],"activity":"Skuteczne natężenie napromienienia dla VIS w zakresie spektralnym 300 – 700 nm\nZakres (10-6 – 399) W/m2\nMetoda pomiaru bezpośredniego (metoda O)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia dla VIS w zakresie spektralnym 300 – 700 nm\nZakres (10-6 – 399) W/m2\nMetoda pomiaru bezpośredniego (metoda O) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia dla VIS w zakresie spektralnym 300 – 700 nm\nZakres (10-6 – 399) W/m2\nMetoda pomiaru bezposredniego (metoda O) PN-EN 14255-2:2010","categories":["environment"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance for VIS in the spectral range 300 – 700 nm","parameters_en":[{"name":"Range","range":"(10-6 – 399) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Effective irradiance for VIS in the spectral range 300 – 700 nm Direct measurement method (method O) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method O)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-6 – 399) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 O） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 O）"},{"_id":"6a83ae76af14b9c0e7b2040c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna dla VIS w zakresie spektralnym 300 – 700 nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna dla VIS w zakresie spektralnym 300 – 700 nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla VIS w zakresie spektralnym 300 – 700 nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla VIS w zakresie spektralnym 300 – 700 nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance for VIS in the spectral range 300 – 700 nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Effective radiance for VIS in the spectral range 300 – 700 nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b2040d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia IRA i IRB w zakresie spektralnym 780 – 3000 nm","parameters":[{"name":"Zakres","range":"(30 – 3999) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia (metoda R)","techniques":["Metoda pomiarowa bezpośrednia (metoda R)"],"computed":[],"activity":"Natężenie napromienienia IRA i IRB w zakresie spektralnym 780 – 3000 nm\nZakres (30 – 3999) W/m2\nMetoda pomiarowa bezpośrednia (metoda R)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia IRA i IRB w zakresie spektralnym 780 – 3000 nm\nZakres (30 – 3999) W/m2\nMetoda pomiarowa bezpośrednia (metoda R) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia IRA i IRB w zakresie spektralnym 780 – 3000 nm\nZakres (30 – 3999) W/m2\nMetoda pomiarowa bezposrednia (metoda R) PN-EN 14255-2:2010","categories":["environment"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance of IRA and IRB in the spectral range 780 – 3000 nm","parameters_en":[{"name":"Range","range":"(30 – 3999) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Irradiance of IRA and IRB in the spectral range 780 – 3000 nm Direct measurement method (method R) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method R)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(30 – 3999) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 R） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 R）"},{"_id":"6a83ae76af14b9c0e7b2040e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie IRA i IRB w zakresie spektralnym 780 – 3000 nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie IRA i IRB w zakresie spektralnym 780 – 3000 nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie IRA i IRB w zakresie spektralnym 780 – 3000 nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie IRA i IRB w zakresie spektralnym 780 – 3000 nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure of IRA and IRB in the spectral range 780 – 3000 nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Radiant exposure of IRA and IRB in the spectral range 780 – 3000 nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b2040f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Natężenie napromienienia VIS, IRA, IRB w zakresie spektralnym 380 – 3000 nm","parameters":[{"name":"Zakres","range":"(30 – 3999) W/m2"}],"technique":"Metoda pomiaru bezpośredniego (metoda X)","techniques":["Metoda pomiaru bezpośredniego (metoda X)"],"computed":[],"activity":"Natężenie napromienienia VIS, IRA, IRB w zakresie spektralnym 380 – 3000 nm\nZakres (30 – 3999) W/m2\nMetoda pomiaru bezpośredniego (metoda X)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Natężenie napromienienia VIS, IRA, IRB w zakresie spektralnym 380 – 3000 nm\nZakres (30 – 3999) W/m2\nMetoda pomiaru bezpośredniego (metoda X) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Natezenie napromienienia VIS, IRA, IRB w zakresie spektralnym 380 – 3000 nm\nZakres (30 – 3999) W/m2\nMetoda pomiaru bezposredniego (metoda X) PN-EN 14255-2:2010","categories":["environment"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Irradiance of VIS, IRA, IRB in the spectral range 380 – 3000 nm","parameters_en":[{"name":"Range","range":"(30 – 3999) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Irradiance of VIS, IRA, IRB in the spectral range 380 – 3000 nm Direct measurement method (method X) Range PN-EN 14255-2:2010","technique_en":"Direct measurement method (method X)","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(30 – 3999) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法（方法 X） 范围 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射","technique_zh":"直接测量法（方法 X）"},{"_id":"6a83ae76af14b9c0e7b20410","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Napromienienie dla VIS, IRA, IRB w zakresie spektralnym: 380 – 3000 nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Napromienienie dla VIS, IRA, IRB w zakresie spektralnym: 380 – 3000 nm (z obliczeń)","reference":"PN-EN 14255-2:2010","norm_bases":["PN-EN 14255-2:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Napromienienie dla VIS, IRA, IRB w zakresie spektralnym: 380 – 3000 nm (z obliczeń) PN-EN 14255-2:2010 Srodowisko pracy – nielaserowe promieniowanie optyczne Napromienienie dla VIS, IRA, IRB w zakresie spektralnym: 380 – 3000 nm (z obliczen) PN-EN 14255-2:2010","categories":["environment"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radiant exposure for VIS, IRA, IRB in the spectral range: 380 – 3000 nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Radiant exposure for VIS, IRA, IRB in the spectral range: 380 – 3000 nm (calculated) PN-EN 14255-2:2010","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-EN 14255-2:2010","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b20411","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia dla VIS, IRA w zakresie spektralnym 380 – 1400 nm","parameters":[{"name":"Zakres","range":"(10-6 – 3999) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia dla VIS, IRA w zakresie spektralnym 380 – 1400 nm\nZakres (10-6 – 3999) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T-05687:2002","norm_bases":["PN-T-05687:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia dla VIS, IRA w zakresie spektralnym 380 – 1400 nm\nZakres (10-6 – 3999) W/m2\nMetoda pomiarowa bezpośrednia PN-T-05687:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia dla VIS, IRA w zakresie spektralnym 380 – 1400 nm\nZakres (10-6 – 3999) W/m2\nMetoda pomiarowa bezposrednia PN-T-05687:2002","categories":["environment"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance for VIS, IRA in the spectral range 380 – 1400 nm","parameters_en":[{"name":"Range","range":"(10-6 – 3999) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Effective irradiance for VIS, IRA in the spectral range 380 – 1400 nm Direct measurement method Range PN-T-05687:2002","technique_en":"Direct measurement method","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-6 – 3999) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法 范围 PN-T-05687:2002","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b20412","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna dla VIS, IRA w zakresie spektralnym 380 – 1400 nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna dla VIS, IRA w zakresie spektralnym 380 – 1400 nm (z obliczeń)","reference":"PN-T-05687:2002","norm_bases":["PN-T-05687:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla VIS, IRA w zakresie spektralnym 380 – 1400 nm (z obliczeń) PN-T-05687:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla VIS, IRA w zakresie spektralnym 380 – 1400 nm (z obliczen) PN-T-05687:2002","categories":["environment"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance for VIS, IRA in the spectral range 380 – 1400 nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Effective radiance for VIS, IRA in the spectral range 380 – 1400 nm (calculated) PN-T-05687:2002","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-T-05687:2002","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b20413","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczne natężenie napromienienia dla IRA w zakresie spektralnym 780 – 1400 nm","parameters":[{"name":"Zakres","range":"(10-3 – 3990) W/m2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne natężenie napromienienia dla IRA w zakresie spektralnym 780 – 1400 nm\nZakres (10-3 – 3990) W/m2\nMetoda pomiarowa bezpośrednia","reference":"PN-T-05687:2002","norm_bases":["PN-T-05687:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natężenie napromienienia dla IRA w zakresie spektralnym 780 – 1400 nm\nZakres (10-3 – 3990) W/m2\nMetoda pomiarowa bezpośrednia PN-T-05687:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczne natezenie napromienienia dla IRA w zakresie spektralnym 780 – 1400 nm\nZakres (10-3 – 3990) W/m2\nMetoda pomiarowa bezposrednia PN-T-05687:2002","categories":["environment"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective irradiance for IRA in the spectral range 780 – 1400 nm","parameters_en":[{"name":"Range","range":"(10-3 – 3990) W/m2"}],"search_en":"Workplace environment – non-laser optical radiation Effective irradiance for IRA in the spectral range 780 – 1400 nm Direct measurement method Range PN-T-05687:2002","technique_en":"Direct measurement method","test_object_en":"Workplace environment – non-laser optical radiation","parameters_zh":[{"name":"范围","range":"(10-3 – 3990) W/m2"}],"search_zh":"工作场所环境 — 非激光光辐射 直接测量法 范围 PN-T-05687:2002","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b20414","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko pracy – nielaserowe promieniowanie optyczne","methodology":"Skuteczna luminancja energetyczna dla IRA w zakresie spektralnym 780 – 1400 nm (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczna luminancja energetyczna dla IRA w zakresie spektralnym 780 – 1400 nm (z obliczeń)","reference":"PN-T-05687:2002","norm_bases":["PN-T-05687:2002"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla IRA w zakresie spektralnym 780 – 1400 nm (z obliczeń) PN-T-05687:2002 Srodowisko pracy – nielaserowe promieniowanie optyczne Skuteczna luminancja energetyczna dla IRA w zakresie spektralnym 780 – 1400 nm (z obliczen) PN-T-05687:2002","categories":["environment"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Effective radiance for IRA in the spectral range 780 – 1400 nm (calculated)","search_en":"Workplace environment – non-laser optical radiation Effective radiance for IRA in the spectral range 780 – 1400 nm (calculated) PN-T-05687:2002","test_object_en":"Workplace environment – non-laser optical radiation","search_zh":"工作场所环境 — 非激光光辐射 PN-T-05687:2002","test_object_zh":"工作场所环境 — 非激光光辐射"},{"_id":"6a83ae76af14b9c0e7b20415","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa","parameters":[],"technique":"Metoda pomiaru ciśnienia różnicowego","techniques":["Metoda pomiaru ciśnienia różnicowego"],"computed":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych > 5 Pa\nMetoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych > 5 Pa\nMetoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","categories":["other"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas velocity and volume flow rate for differential pressures > 5 Pa","search_en":"Waste gases Gas velocity and volume flow rate for differential pressures > 5 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","technique_en":"Differential pressure measurement method","test_object_en":"Waste gases","search_zh":"废气 压差 > 5 Pa 时的气体流速与体积流量 差压测量法 PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017","test_object_zh":"废气","technique_zh":"差压测量法","methodology_zh":"压差 > 5 Pa 时的气体流速与体积流量"},{"_id":"6a83ae76af14b9c0e7b20416","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[{"name":"Prędkość"},{"name":"Zakres","range":"(0,15 – 19,5) m/s"},{"name":"Prędkość"},{"name":"Zakres","range":"(0,40 – 25) m/s"}],"technique":"Metoda spiętrzenia; Metoda termoanemometryczna; Metoda anemometryczna","techniques":["Metoda spiętrzenia","Metoda termoanemometryczna","Metoda anemometryczna"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość\nZakres (0,15 – 19,5) m/s\nPrędkość\nZakres (0,40 – 25) m/s\nMetoda spiętrzenia; Metoda termoanemometryczna; Metoda anemometryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nZakres:\nPrędkość\nZakres (0,15 – 19,5) m/s\nPrędkość\nZakres (0,40 – 25) m/s\nMetoda spiętrzenia; Metoda termoanemometryczna; Metoda anemometryczna PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nZakres:\nPredkosc\nZakres (0,15 – 19,5) m/s\nPredkosc\nZakres (0,40 – 25) m/s\nMetoda spietrzenia; Metoda termoanemometryczna; Metoda anemometryczna PN-Z-04030-7:1994","categories":["other"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","parameters_en":[{"name":"Velocity"},{"name":"Range","range":"(0,15 – 19,5) m/s"},{"name":"Velocity"},{"name":"Range","range":"(0,40 – 25) m/s"}],"search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method; Thermoanemometric method; Anemometric method Velocity Range Velocity Range PN-Z-04030-7:1994","technique_en":"Stagnation pressure method; Thermoanemometric method; Anemometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"速度"},{"name":"范围","range":"(0,15 – 19,5) m/s"},{"name":"速度"},{"name":"范围","range":"(0,40 – 25) m/s"}],"search_zh":"废气 动压 > 10 Pa 时的气体体积流量 速度 范围 速度 范围 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量"},{"_id":"6a83ae76af14b9c0e7b20417","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-Z-04030-7:1994","categories":["other"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a83ae76af14b9c0e7b20418","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(1,0 – 100000) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (1,0 – 100000) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (1,0 – 100000) mg/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (1,0 – 100000) mg/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100000) mg/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100000) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b20419","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a83ae76af14b9c0e7b2041a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of dust concentration","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a83ae76af14b9c0e7b2041b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,5 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,5 – 50) mg/m3"}],"search_en":"Waste gases Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 50) mg/m3"}],"search_zh":"废气 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b2041c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","search_en":"Waste gases Dust emission (calculated) PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a83ae76af14b9c0e7b2041d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"Zakres","range":"(0,5 – 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie tlenu\nZakres (0,5 – 21) %\nMetoda paramagnetyczna","reference":"PN-ISO 10396:2001 | PN-EN 14789:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14789:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nZakres (0,5 – 21) %\nMetoda paramagnetyczna PN-ISO 10396:2001 | PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu\nZakres (0,5 – 21) %\nMetoda paramagnetyczna PN-ISO 10396:2001 | PN-EN 14789:2017-04","categories":["other"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 21) %"}],"search_en":"Waste gases Oxygen concentration Paramagnetic method Range PN-ISO 10396:2001 | PN-EN 14789:2017-04","technique_en":"Paramagnetic method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,5 – 21) %"}],"search_zh":"废气 氧浓度 顺磁法 范围 PN-ISO 10396:2001 | PN-EN 14789:2017-04","test_object_zh":"废气","methodology_zh":"氧浓度","technique_zh":"顺磁法"},{"_id":"6a83ae76af14b9c0e7b2041e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku węgla","parameters":[{"name":"Zakres"},{"name":"CO2","range":"(0,03 – 18) %"}],"technique":"Metoda (NDIR)","techniques":["Metoda (NDIR)"],"computed":[],"activity":"Stężenie dwutlenku węgla\nZakres:\nZakres\nCO2 (0,03 – 18) %\nMetoda (NDIR)","reference":"PN-ISO 10396:2001 | ISO 12039:2019","norm_bases":["PN-ISO 10396:2001","ISO 12039:2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla\nZakres:\nZakres\nCO2 (0,03 – 18) %\nMetoda (NDIR) PN-ISO 10396:2001 | ISO 12039:2019 Gazy odlotowe Stezenie dwutlenku wegla\nZakres:\nZakres\nCO2 (0,03 – 18) %\nMetoda (NDIR) PN-ISO 10396:2001 | ISO 12039:2019","categories":["other"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide concentration","parameters_en":[{"name":"Range"},{"name":"CO2","range":"(0,03 – 18) %"}],"search_en":"Waste gases Carbon dioxide concentration Method (NDIR) Range CO2 PN-ISO 10396:2001 | ISO 12039:2019","technique_en":"Method (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围"},{"name":"CO2","range":"(0,03 – 18) %"}],"search_zh":"废气 二氧化碳浓度 范围 CO2 PN-ISO 10396:2001 | ISO 12039:2019","test_object_zh":"废气","methodology_zh":"二氧化碳浓度"},{"_id":"6a83ae76af14b9c0e7b2041f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja dwutlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku węgla (z obliczeń)","reference":"PN-ISO 10396:2001 | ISO 12039:2019","norm_bases":["PN-ISO 10396:2001","ISO 12039:2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja dwutlenku węgla (z obliczeń) PN-ISO 10396:2001 | ISO 12039:2019 Gazy odlotowe Emisja dwutlenku wegla (z obliczen) PN-ISO 10396:2001 | ISO 12039:2019","categories":["environment"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon dioxide emission (calculated)","search_en":"Waste gases Carbon dioxide emission (calculated) PN-ISO 10396:2001 | ISO 12039:2019","test_object_en":"Waste gases","search_zh":"废气 二氧化碳排放（由计算得出） PN-ISO 10396:2001 | ISO 12039:2019","test_object_zh":"废气","methodology_zh":"二氧化碳排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20420","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku azotu, tlenków azotu, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3","parameters":[],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenku azotu, tlenków azotu, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["other"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3 Chemiluminescence method PN-ISO 10396:2001 | PN-EN 14792:2017-04","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","search_zh":"废气 化学发光法 PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气","technique_zh":"化学发光法"},{"_id":"6a83ae76af14b9c0e7b20421","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-ISO 10396:2001 | PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-ISO 10396:2001 | PN-EN 14792:2017-04","categories":["environment"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx emission (NO and NO2 calculated as NO2) (calculated)","search_en":"Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated) PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_en":"Waste gases","search_zh":"废气 NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出） PN-ISO 10396:2001 | PN-EN 14792:2017-04","test_object_zh":"废气","methodology_zh":"NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20422","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie ditlenku azotu NO2","parameters":[{"name":"Zakres","range":"(2 – 200) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie ditlenku azotu NO2\nZakres (2 – 200) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04 IR-394/W1-17.01.2020"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie ditlenku azotu NO2\nZakres (2 – 200) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020 Gazy odlotowe Stezenie ditlenku azotu NO2\nZakres (2 – 200) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","categories":["other"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide NO2 concentration","parameters_en":[{"name":"Range","range":"(2 – 200) mg/m3"}],"search_en":"Waste gases Nitrogen dioxide NO2 concentration Chemiluminescence method Range PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2 – 200) mg/m3"}],"search_zh":"废气 化学发光法 范围 PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","test_object_zh":"废气","technique_zh":"化学发光法"},{"_id":"6a83ae76af14b9c0e7b20423","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO2 (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04 IR-394/W1-17.01.2020"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO2 (z obliczeń) PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020 Gazy odlotowe Emisja NO2 (z obliczen) PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","categories":["environment"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO2 emission (calculated)","search_en":"Waste gases NO2 emission (calculated) PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","test_object_en":"Waste gases","search_zh":"废气 PN-ISO 10396:2001 | PN-EN 14792:2017-04 IR-394/W1-17.01.2020","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b20424","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres"},{"name":"CO","range":"(1,25 – 1500) mg/m3"}],"technique":"Metoda (NDIR)","techniques":["Metoda (NDIR)"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres\nCO (1,25 – 1500) mg/m3\nMetoda (NDIR)","reference":"PN-ISO 10396:2001 | PN-EN 15058:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 15058:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenku węgla\nZakres:\nZakres\nCO (1,25 – 1500) mg/m3\nMetoda (NDIR) PN-ISO 10396:2001 | PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla\nZakres:\nZakres\nCO (1,25 – 1500) mg/m3\nMetoda (NDIR) PN-ISO 10396:2001 | PN-EN 15058:2017-04","categories":["other"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range"},{"name":"CO","range":"(1,25 – 1500) mg/m3"}],"search_en":"Waste gases Carbon monoxide concentration Method (NDIR) Range CO PN-ISO 10396:2001 | PN-EN 15058:2017-04","technique_en":"Method (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围"},{"name":"CO","range":"(1,25 – 1500) mg/m3"}],"search_zh":"废气 一氧化碳浓度 范围 CO PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳浓度"},{"_id":"6a83ae76af14b9c0e7b20425","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja tlenku węgla (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja tlenku węgla (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 15058:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 15058:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja tlenku węgla (z obliczeń) PN-ISO 10396:2001 | PN-EN 15058:2017-04 Gazy odlotowe Emisja tlenku wegla (z obliczen) PN-ISO 10396:2001 | PN-EN 15058:2017-04","categories":["environment"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide emission (calculated)","search_en":"Waste gases Carbon monoxide emission (calculated) PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_en":"Waste gases","search_zh":"废气 一氧化碳排放（由计算得出） PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_zh":"废气","methodology_zh":"一氧化碳排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20426","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku siarki SO2","parameters":[{"name":"Zakres","range":"(20 – 2860) mg/m3"}],"technique":"Metoda (NDIR)","techniques":["Metoda (NDIR)"],"computed":[],"activity":"Stężenie dwutlenku siarki SO2\nZakres (20 – 2860) mg/m3\nMetoda (NDIR)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku siarki SO2\nZakres (20 – 2860) mg/m3\nMetoda (NDIR) PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku siarki SO2\nZakres (20 – 2860) mg/m3\nMetoda (NDIR) PN-ISO 10396:2001","categories":["other"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide SO2 concentration","parameters_en":[{"name":"Range","range":"(20 – 2860) mg/m3"}],"search_en":"Waste gases Sulfur dioxide SO2 concentration Method (NDIR) Range PN-ISO 10396:2001","technique_en":"Method (NDIR)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(20 – 2860) mg/m3"}],"search_zh":"废气 二氧化硫 SO2 浓度 范围 PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"二氧化硫 SO2 浓度"},{"_id":"6a83ae76af14b9c0e7b20427","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja dwutlenku siarki (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku siarki (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja dwutlenku siarki (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja dwutlenku siarki (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphur dioxide emission (calculated)","search_en":"Waste gases Sulphur dioxide emission (calculated) PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 二氧化硫排放（由计算得出） PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"二氧化硫排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20428","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(2 – 1000) mg/m3"}],"search_en":"Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/m3"}],"search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a83ae76af14b9c0e7b20429","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05","categories":["environment"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05","test_object_en":"Waste gases","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值） PN-EN 12619:2013-05","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a83ae76af14b9c0e7b2042a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"zakres","range":"(4 – 40) % obj."},{"name":"Zawartość pary wodnej"},{"name":"zakres","range":"(29 – 250) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nzakres (4 – 40) % obj.\nZawartość pary wodnej\nzakres (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-4","norm_bases":["PN-EN 14790:2017-4"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O)\nZakres:\nzakres (4 – 40) % obj.\nZawartość pary wodnej\nzakres (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-4 Gazy odlotowe Stezenie pary wodnej (H2O)\nZakres:\nzakres (4 – 40) % obj.\nZawartosc pary wodnej\nzakres (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-4","categories":["other"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"range","range":"(4 – 40) % obj."},{"name":"Water vapour content"},{"name":"range","range":"(29 – 250) g/m3"}],"search_en":"Waste gases Water vapour concentration (H2O) Condensation-adsorption method range Water vapour content range PN-EN 14790:2017-4","technique_en":"Condensation-adsorption method","test_object_en":"Waste gases","search_zh":"废气 水蒸气浓度（H2O） 冷凝-吸附法 范围 水蒸气含量 范围 PN-EN 14790:2017-4","test_object_zh":"废气","parameters_zh":[{"name":"范围","range":"(4 – 40) % obj."},{"name":"水蒸气含量"},{"name":"范围","range":"(29 – 250) g/m3"}],"methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a83ae76af14b9c0e7b2042b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia PCDD/PCDF","parameters":[],"technique":"Metoda filtracji i kondensacji","techniques":["Metoda filtracji i kondensacji"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia PCDD/PCDF\nMetoda filtracji i kondensacji","reference":"PN-EN 1948-1:2006+Ap1:2017-08","norm_bases":["PN-EN 1948-1:2006+Ap1:2017-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia PCDD/PCDF\nMetoda filtracji i kondensacji PN-EN 1948-1:2006+Ap1:2017-08 Gazy odlotowe Pobieranie probek do oznaczania stezenia PCDD/PCDF\nMetoda filtracji i kondensacji PN-EN 1948-1:2006+Ap1:2017-08","categories":["other"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of PCDD/PCDF concentration","search_en":"Waste gases Sampling for the determination of PCDD/PCDF concentration Filtration and condensation method PN-EN 1948-1:2006+Ap1:2017-08","technique_en":"Filtration and condensation method","test_object_en":"Waste gases","search_zh":"废气 用于测定 PCDD/PCDF 浓度的采样 过滤与冷凝法 PN-EN 1948-1:2006+Ap1:2017-08","test_object_zh":"废气","methodology_zh":"用于测定 PCDD/PCDF 浓度的采样","technique_zh":"过滤与冷凝法"},{"_id":"6a83ae76af14b9c0e7b2042c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja PCDD/PCDF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja PCDD/PCDF (z obliczeń)","reference":"PN-EN 1948-1:2006+Ap1:2017-08","norm_bases":["PN-EN 1948-1:2006+Ap1:2017-08"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja PCDD/PCDF (z obliczeń) PN-EN 1948-1:2006+Ap1:2017-08 Gazy odlotowe Emisja PCDD/PCDF (z obliczen) PN-EN 1948-1:2006+Ap1:2017-08","categories":["environment"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PCDD/PCDF emission (calculated)","search_en":"Waste gases PCDD/PCDF emission (calculated) PN-EN 1948-1:2006+Ap1:2017-08","test_object_en":"Waste gases","search_zh":"废气 PCDD/PCDF 排放（由计算得出） PN-EN 1948-1:2006+Ap1:2017-08","test_object_zh":"废气","methodology_zh":"PCDD/PCDF 排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b2042d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia PCB","parameters":[],"technique":"Metoda filtracji i kondensacji","techniques":["Metoda filtracji i kondensacji"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia PCB\nMetoda filtracji i kondensacji","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia PCB\nMetoda filtracji i kondensacji PN-EN 1948-4+A1:2014-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia PCB\nMetoda filtracji i kondensacji PN-EN 1948-4+A1:2014-03","categories":["other"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of PCB concentration","search_en":"Waste gases Sampling for determination of PCB concentration Filtration and condensation method PN-EN 1948-4+A1:2014-03","technique_en":"Filtration and condensation method","test_object_en":"Waste gases","search_zh":"废气 过滤与冷凝法 PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","technique_zh":"过滤与冷凝法"},{"_id":"6a83ae76af14b9c0e7b2042e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja PCB (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja PCB (z obliczeń)","reference":"PN-EN 1948-4+A1:2014-03","norm_bases":["PN-EN 1948-4+A1:2014-03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja PCB (z obliczeń) PN-EN 1948-4+A1:2014-03 Gazy odlotowe Emisja PCB (z obliczen) PN-EN 1948-4+A1:2014-03","categories":["environment"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PCB emission (calculated)","search_en":"Waste gases PCB emission (calculated) PN-EN 1948-4+A1:2014-03","test_object_en":"Waste gases","search_zh":"废气 PCB 排放（由计算得出） PN-EN 1948-4+A1:2014-03","test_object_zh":"废气","methodology_zh":"PCB 排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b2042f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen chloride concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of hydrogen chloride concentration PN-EN 1911:2011","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 氯化氢浓度测定采样 PN-EN 1911:2011","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a83ae76af14b9c0e7b20430","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,2 – 750) mg/m3"},{"name":"Zakres","range":"(0,0250 – 37,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,2 – 750) mg/m3\nZakres (0,0250 – 37,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość chlorowodoru\nZakres:\nZakres (0,2 – 750) mg/m3\nZakres (0,0250 – 37,0) mg w próbce\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc chlorowodoru\nZakres:\nZakres (0,2 – 750) mg/m3\nZakres (0,0250 – 37,0) mg w probce\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration / content","parameters_en":[{"name":"Range","range":"(0,2 – 750) mg/m3"},{"name":"Range","range":"(0,0250 – 37,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Hydrogen chloride concentration / content Spectrophotometric method Range Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,2 – 750) mg/m3"},{"name":"范围","range":"(0,0250 – 37,0) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 氯化氢的浓度/含量 分光光度法 范围 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20431","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja chlorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja chlorowodoru (z obliczeń) PN-EN 1911:2011 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja chlorowodoru (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Hydrogen chloride emission (calculated) PN-EN 1911:2011","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 氯化氢排放量（计算值） PN-EN 1911:2011","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a83ae76af14b9c0e7b20432","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia SO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-4","norm_bases":["PN-EN 14791:2017-4"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-4 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-4","categories":["other"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of SO2 concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of SO2 concentration PN-EN 14791:2017-4","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 用于测定 SO2 浓度的采样 PN-EN 14791:2017-4","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a83ae76af14b9c0e7b20433","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie dwutlenku siarki SO2","parameters":[{"name":"Zakres","range":"(1 – 2000) mg/m3"},{"name":"Zakres","range":"(0,1 – 40) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie dwutlenku siarki SO2\nZakres:\nZakres (1 – 2000) mg/m3\nZakres (0,1 – 40) mg w próbce\nMetoda toronowa","reference":"PN-EN 14791:2017-4","norm_bases":["PN-EN 14791:2017-4"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie dwutlenku siarki SO2\nZakres:\nZakres (1 – 2000) mg/m3\nZakres (0,1 – 40) mg w próbce\nMetoda toronowa PN-EN 14791:2017-4 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie dwutlenku siarki SO2\nZakres:\nZakres (1 – 2000) mg/m3\nZakres (0,1 – 40) mg w probce\nMetoda toronowa PN-EN 14791:2017-4","categories":["other"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide SO2 concentration","parameters_en":[{"name":"Range","range":"(1 – 2000) mg/m3"},{"name":"Range","range":"(0,1 – 40) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Sulfur dioxide SO2 concentration Thoron method Range Range PN-EN 14791:2017-4","technique_en":"Thoron method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(1 – 2000) mg/m3"},{"name":"范围","range":"(0,1 – 40) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 二氧化硫 SO2 浓度 钍射气法 范围 范围 PN-EN 14791:2017-4","technique_zh":"钍射气法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"二氧化硫 SO2 浓度"},{"_id":"6a83ae76af14b9c0e7b20434","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja dwutlenku siarki (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku siarki (z obliczeń)","reference":"PN-EN 14791:2017-4","norm_bases":["PN-EN 14791:2017-4"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja dwutlenku siarki (z obliczeń) PN-EN 14791:2017-4 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja dwutlenku siarki (z obliczen) PN-EN 14791:2017-4","categories":["environment"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphur dioxide emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Sulphur dioxide emission (calculated) PN-EN 14791:2017-4","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 二氧化硫排放（由计算得出） PN-EN 14791:2017-4","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"二氧化硫排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20435","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen fluoride concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of hydrogen fluoride concentration ISO 15713:2006","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 氟化氢浓度测定采样 ISO 15713:2006","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a83ae76af14b9c0e7b20436","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie fluorowodoru","parameters":[{"name":"Zakres","range":"(0,05 – 200) mg/m3"},{"name":"Zakres","range":"(0,0053 – 5,3) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorowodoru\nZakres:\nZakres (0,05 – 200) mg/m3\nZakres (0,0053 – 5,3) mg w próbce\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie fluorowodoru\nZakres:\nZakres (0,05 – 200) mg/m3\nZakres (0,0053 – 5,3) mg w próbce\nMetoda potencjometryczna ISO 15713:2006 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie fluorowodoru\nZakres:\nZakres (0,05 – 200) mg/m3\nZakres (0,0053 – 5,3) mg w probce\nMetoda potencjometryczna ISO 15713:2006","categories":["other"],"row_index":179,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride concentration","parameters_en":[{"name":"Range","range":"(0,05 – 200) mg/m3"},{"name":"Range","range":"(0,0053 – 5,3) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Hydrogen fluoride concentration Potentiometric method Range Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,05 – 200) mg/m3"},{"name":"范围","range":"(0,0053 – 5,3) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 氟化氢浓度 电位法 范围 范围 ISO 15713:2006","technique_zh":"电位法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氟化氢浓度"},{"_id":"6a83ae76af14b9c0e7b20437","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja fluorowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluorowodoru (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja fluorowodoru (z obliczeń) ISO 15713:2006 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja fluorowodoru (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":180,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Hydrogen fluoride emission (calculated) ISO 15713:2006","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 氟化氢排放（由计算得出） ISO 15713:2006","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氟化氢排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20438","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211:2006 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211:2006","categories":["other"],"row_index":181,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of total mercury concentration","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Sampling for determination of total mercury concentration PN-EN 13211:2006","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","methodology_zh":"总汞浓度测定采样","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 总汞浓度测定采样 PN-EN 13211:2006","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20439","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Emisja rtęci ogólnej (z obliczeń) PN-EN 13211:2006 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Emisja rteci ogolnej (z obliczen) PN-EN 13211:2006","categories":["environment"],"row_index":182,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mercury emission (calculated)","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Total mercury emission (calculated) PN-EN 13211:2006","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","methodology_zh":"总汞排放量（计算值）","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 总汞排放量（计算值） PN-EN 13211:2006","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2043a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05","categories":["materials"],"row_index":183,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2025-05","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","methodology_zh":"用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V PN-EN 14385:2025-05","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2043b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Emisja metali : As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja metali : As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Emisja metali : As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Emisja metali : As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen) PN-EN 14385:2025-05","categories":["materials","environment"],"row_index":184,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal emission : As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Metal emission : As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) PN-EN 14385:2025-05","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出） PN-EN 14385:2025-05","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品","methodology_zh":"金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b2043c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":185,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","search_en":"Waste gases – waste gas samples collected into sorbent tubes Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","methodology_zh":"单项气态有机化合物浓度测定采样","search_zh":"排放气体 － 采集于吸附管中的排放气体样品 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2043d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Stężenie / zawartość indywidualnych gazowych związków organicznych","parameters":[{"name":"trójchloroetylenu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"dichlorometanu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010– 2,0) mg w próbce"},{"name":"tetrachloroetylenu"},{"name":"Zakres","range":"( 0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"tetrachlorku węgla"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"alkoholu etylowego"},{"name":"Zakres","range":"( 0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"eteru dietylowego"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"2-metoksymetyloetoksy propanolu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"alkoholu butoksyetylowego","range":"(2-butoksyetanolu)"},{"name":"Zakres","range":"( 0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"trimetylobenzenu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 1,0) mg w próbce"},{"name":"1-metoksypropan-2-olu"},{"name":"Zakres","range":"(5,0 – 100) mg/m3"},{"name":"Zakres","range":"(0,10– 2,0) mg w próbce"},{"name":"alkoholu izopropylowego","range":"(propan-2-olu)"},{"name":"Zakres","range":"(5,0 – 100) mg/m3"},{"name":"Zakres","range":"(0,10 – 2,0) mg w próbce"},{"name":"alkoholu propylowego","range":"(propan-1-olu)"},{"name":"Zakres","range":"(5,0 – 100) mg/m3"},{"name":"Zakres","range":"(0,10 – 2,0) mg w próbce"},{"name":"pentanu"},{"name":"Zakres","range":"(0,05 – 250) mg/m3"},{"name":"Zakres","range":"(0,001 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\ntrójchloroetylenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ndichlorometanu\nZakres (0,50 – 100) mg/m3\nZakres (0,010– 2,0) mg w próbce\ntetrachloroetylenu\nZakres ( 0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ntetrachlorku węgla\nZakres (0,050 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nalkoholu etylowego\nZakres ( 0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\neteru dietylowego\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\n2-metoksymetyloetoksy propanolu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nalkoholu butoksyetylowego (2-butoksyetanolu)\nZakres ( 0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ntrimetylobenzenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 1,0) mg w próbce\n1-metoksypropan-2-olu\nZakres (5,0 – 100) mg/m3\nZakres (0,10– 2,0) mg w próbce\nalkoholu izopropylowego (propan-2-olu)\nZakres (5,0 – 100) mg/m3\nZakres (0,10 – 2,0) mg w próbce\nalkoholu propylowego (propan-1-olu)\nZakres (5,0 – 100) mg/m3\nZakres (0,10 – 2,0) mg w próbce\npentanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\ntrójchloroetylenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ndichlorometanu\nZakres (0,50 – 100) mg/m3\nZakres (0,010– 2,0) mg w próbce\ntetrachloroetylenu\nZakres ( 0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ntetrachlorku węgla\nZakres (0,050 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nalkoholu etylowego\nZakres ( 0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\neteru dietylowego\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\n2-metoksymetyloetoksy propanolu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nalkoholu butoksyetylowego (2-butoksyetanolu)\nZakres ( 0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ntrimetylobenzenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 1,0) mg w próbce\n1-metoksypropan-2-olu\nZakres (5,0 – 100) mg/m3\nZakres (0,10– 2,0) mg w próbce\nalkoholu izopropylowego (propan-2-olu)\nZakres (5,0 – 100) mg/m3\nZakres (0,10 – 2,0) mg w próbce\nalkoholu propylowego (propan-1-olu)\nZakres (5,0 – 100) mg/m3\nZakres (0,10 – 2,0) mg w próbce\npentanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Stezenie / zawartosc indywidualnych gazowych zwiazkow organicznych\nZakres:\ntrojchloroetylenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\ndichlorometanu\nZakres (0,50 – 100) mg/m3\nZakres (0,010– 2,0) mg w probce\ntetrachloroetylenu\nZakres ( 0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\ntetrachlorku wegla\nZakres (0,050 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nalkoholu etylowego\nZakres ( 0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\neteru dietylowego\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\n2-metoksymetyloetoksy propanolu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nalkoholu butoksyetylowego (2-butoksyetanolu)\nZakres ( 0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\ntrimetylobenzenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 1,0) mg w probce\n1-metoksypropan-2-olu\nZakres (5,0 – 100) mg/m3\nZakres (0,10– 2,0) mg w probce\nalkoholu izopropylowego (propan-2-olu)\nZakres (5,0 – 100) mg/m3\nZakres (0,10 – 2,0) mg w probce\nalkoholu propylowego (propan-1-olu)\nZakres (5,0 – 100) mg/m3\nZakres (0,10 – 2,0) mg w probce\npentanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":186,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of individual gaseous organic compounds","parameters_en":[{"name":"trichloroethylene"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"dichloromethane"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010– 2,0) mg w próbce"},{"name":"tetrachloroethylene"},{"name":"Range","range":"( 0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"carbon tetrachloride"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"ethyl alcohol"},{"name":"Range","range":"( 0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"diethyl ether"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"2-methoxymethylethoxy propanol"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"butoxyethyl alcohol","range":"(2-butoksyetanolu)"},{"name":"Range","range":"( 0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"trimethylbenzene"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 1,0) mg w próbce"},{"name":"1-methoxypropan-2-ol"},{"name":"Range","range":"(5,0 – 100) mg/m3"},{"name":"Range","range":"(0,10– 2,0) mg w próbce"},{"name":"isopropyl alcohol","range":"(propan-2-olu)"},{"name":"Range","range":"(5,0 – 100) mg/m3"},{"name":"Range","range":"(0,10 – 2,0) mg w próbce"},{"name":"propyl alcohol","range":"(propan-1-olu)"},{"name":"Range","range":"(5,0 – 100) mg/m3"},{"name":"Range","range":"(0,10 – 2,0) mg w próbce"},{"name":"pentane"},{"name":"Range","range":"(0,05 – 250) mg/m3"},{"name":"Range","range":"(0,001 – 5,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into sorbent tubes Concentration / content of individual gaseous organic compounds Gas chromatography with flame ionization detection (GC-FID) trichloroethylene Range Range dichloromethane Range Range tetrachloroethylene Range Range carbon tetrachloride Range Range ethyl alcohol Range Range diethyl ether Range Range 2-methoxymethylethoxy propanol Range Range butoxyethyl alcohol Range Range trimethylbenzene Range Range 1-methoxypropan-2-ol Range Range isopropyl alcohol Range Range propyl alcohol Range Range pentane Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","parameters_zh":[{"name":"trójchloroetylenu"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"dichlorometanu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010– 2,0) mg w próbce"},{"name":"tetrachloroetylenu"},{"name":"范围","range":"( 0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"tetrachlorku węgla"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"alkoholu etylowego"},{"name":"范围","range":"( 0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"eteru dietylowego"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"2-metoksymetyloetoksy propanolu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"alkoholu butoksyetylowego","range":"(2-butoksyetanolu)"},{"name":"范围","range":"( 0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"trimetylobenzenu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 1,0) mg w próbce"},{"name":"1-甲氧基-2-丙醇"},{"name":"范围","range":"(5,0 – 100) mg/m3"},{"name":"范围","range":"(0,10– 2,0) mg w próbce"},{"name":"alkoholu izopropylowego","range":"(propan-2-olu)"},{"name":"范围","range":"(5,0 – 100) mg/m3"},{"name":"范围","range":"(0,10 – 2,0) mg w próbce"},{"name":"alkoholu propylowego","range":"(propan-1-olu)"},{"name":"范围","range":"(5,0 – 100) mg/m3"},{"name":"范围","range":"(0,10 – 2,0) mg w próbce"},{"name":"pentanu"},{"name":"范围","range":"(0,05 – 250) mg/m3"},{"name":"范围","range":"(0,001 – 5,0) mg w próbce"}],"search_zh":"排放气体 － 采集于吸附管中的排放气体样品 单个气态有机化合物的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 1-甲氧基-2-丙醇 范围 范围 范围 范围 范围 范围 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品","methodology_zh":"单个气态有机化合物的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b2043e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":187,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","search_en":"Waste gases – waste gas samples collected into sorbent tubes Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","methodology_zh":"单项气态有机化合物排放量（计算值）","search_zh":"排放气体 － 采集于吸附管中的排放气体样品 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2043f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Stężenie / zawartość indywidualnych gazowych związków organicznych","parameters":[{"name":"heksanu"},{"name":"Zakres","range":"(0,05 – 250) mg/m3"},{"name":"Zakres","range":"(0,001 – 5,0) mg w próbce"},{"name":"heptanu"},{"name":"Zakres","range":"(0,05 – 250) mg/m3"},{"name":"Zakres","range":"(0,001 – 5,0) mg w próbce oktanu"},{"name":"Zakres","range":"(0,05 – 250) mg/m3"},{"name":"Zakres","range":"(0,001 – 5,0) mg w próbce"},{"name":"metylocykloheksanu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"butan-2-olu (alkoholu sec-butylowego)"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"dietylobenzenu"},{"name":"Zakres","range":"(0,05 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"octanu 2-butoksyetylu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"octanu sec-butylu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"octanu tert-butylu"},{"name":"Zakres","range":"(0,050 – 100)"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"octanu 2-metoksy-1-metyloetylu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"octanu izobutylu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"acetonu"},{"name":"Zakres","range":"(0,050– 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"alkoholu furfurylowego","range":"(2-furylometanolu)"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"benzenu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"butan-1-olu (alkohol butylowy)"},{"name":"Zakres","range":"(0,050 – 250) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\nheksanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nheptanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce oktanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nmetylocykloheksanu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nbutan-2-olu (alkoholu sec-butylowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ndietylobenzenu\nZakres (0,05 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu 2-butoksyetylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu sec-butylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu tert-butylu\nZakres (0,050 – 100)\nZakres (0,0010 – 2,0) mg w próbce\noctanu 2-metoksy-1-metyloetylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\noctanu izobutylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nacetonu\nZakres (0,050– 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nalkoholu furfurylowego (2-furylometanolu)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nbenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nbutan-1-olu (alkohol butylowy)\nZakres (0,050 – 250) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\nheksanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nheptanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce oktanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nmetylocykloheksanu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nbutan-2-olu (alkoholu sec-butylowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ndietylobenzenu\nZakres (0,05 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu 2-butoksyetylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu sec-butylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu tert-butylu\nZakres (0,050 – 100)\nZakres (0,0010 – 2,0) mg w próbce\noctanu 2-metoksy-1-metyloetylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\noctanu izobutylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nacetonu\nZakres (0,050– 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nalkoholu furfurylowego (2-furylometanolu)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nbenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nbutan-1-olu (alkohol butylowy)\nZakres (0,050 – 250) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Stezenie / zawartosc indywidualnych gazowych zwiazkow organicznych\nZakres:\nheksanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w probce\nheptanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w probce oktanu\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w probce\nmetylocykloheksanu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nbutan-2-olu (alkoholu sec-butylowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\ndietylobenzenu\nZakres (0,05 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\noctanu 2-butoksyetylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\noctanu sec-butylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\noctanu tert-butylu\nZakres (0,050 – 100)\nZakres (0,0010 – 2,0) mg w probce\noctanu 2-metoksy-1-metyloetylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\noctanu izobutylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nacetonu\nZakres (0,050– 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nalkoholu furfurylowego (2-furylometanolu)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nbenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nbutan-1-olu (alkohol butylowy)\nZakres (0,050 – 250) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":188,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of individual gaseous organic compounds","parameters_en":[{"name":"hexane"},{"name":"Range","range":"(0,05 – 250) mg/m3"},{"name":"Range","range":"(0,001 – 5,0) mg w próbce"},{"name":"heptane"},{"name":"Range","range":"(0,05 – 250) mg/m3"},{"name":"Range","range":"(0,001 – 5,0) mg w próbce oktanu"},{"name":"Range","range":"(0,05 – 250) mg/m3"},{"name":"Range","range":"(0,001 – 5,0) mg w próbce"},{"name":"methylcyclohexane"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"butan-2-ol (sec-butyl alcohol)"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"diethylbenzene"},{"name":"Range","range":"(0,05 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"2-butoxyethyl acetate"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"sec-butyl acetate"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"tert-butyl acetate"},{"name":"Range","range":"(0,050 – 100)"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"2-methoxy-1-methylethyl acetate"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"isobutyl acetate"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"acetone"},{"name":"Range","range":"(0,050– 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"furfuryl alcohol","range":"(2-furylometanolu)"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"benzene"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"butan-1-ol (butyl alcohol)"},{"name":"Range","range":"(0,050 – 250) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into sorbent tubes Concentration / content of individual gaseous organic compounds Gas chromatography with flame ionization detection (GC-FID) hexane Range Range heptane Range Range Range Range methylcyclohexane Range Range butan-2-ol (sec-butyl alcohol) Range Range diethylbenzene Range Range 2-butoxyethyl acetate Range Range sec-butyl acetate Range Range tert-butyl acetate Range Range 2-methoxy-1-methylethyl acetate Range Range isobutyl acetate Range Range acetone Range Range furfuryl alcohol Range Range benzene Range Range butan-1-ol (butyl alcohol) Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","parameters_zh":[{"name":"正己烷"},{"name":"范围","range":"(0,05 – 250) mg/m3"},{"name":"范围","range":"(0,001 – 5,0) mg w próbce"},{"name":"heptanu"},{"name":"范围","range":"(0,05 – 250) mg/m3"},{"name":"范围","range":"(0,001 – 5,0) mg w próbce oktanu"},{"name":"范围","range":"(0,05 – 250) mg/m3"},{"name":"范围","range":"(0,001 – 5,0) mg w próbce"},{"name":"甲基环己烷"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"butan-2-olu (alkoholu sec-butylowego)"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"dietylobenzenu"},{"name":"范围","range":"(0,05 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"乙二醇丁醚醋酸酯"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"octanu sec-butylu"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"octanu tert-butylu"},{"name":"范围","range":"(0,050 – 100)"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"丙二醇甲醚醋酸酯"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"octanu izobutylu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"丙酮"},{"name":"范围","range":"(0,050– 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"alkoholu furfurylowego","range":"(2-furylometanolu)"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"苯"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"butan-1-olu (alkohol butylowy)"},{"name":"范围","range":"(0,050 – 250) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"}],"search_zh":"排放气体 － 采集于吸附管中的排放气体样品 单个气态有机化合物的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 正己烷 范围 范围 范围 范围 范围 范围 甲基环己烷 范围 范围 范围 范围 范围 范围 乙二醇丁醚醋酸酯 范围 范围 范围 范围 范围 范围 丙二醇甲醚醋酸酯 范围 范围 范围 范围 丙酮 范围 范围 范围 范围 苯 范围 范围 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品","methodology_zh":"单个气态有机化合物的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20440","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Stężenie / zawartość indywidualnych gazowych związków organicznych","parameters":[{"name":"butan-2-onu (metyloetyloketon)"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"chloroformu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"cykloheksanu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"cykloheksanolu"},{"name":"Zakres","range":"(0,50– 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"cykloheksanonu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"disiarczku węgla"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"etylobenzenu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"izopropylobenzenu (kumenu)"},{"name":"Zakres","range":"(0,5 – 100) mg/m3"},{"name":"Zakres","range":"(0,010– 2,0) mg w próbce"},{"name":"ksylenu"},{"name":"Zakres","range":"(0,05 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"2-metylopropan-1-olu (alkoholu izobutylowego)"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"mezytylenu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 5,0) mg w próbce"},{"name":"octanu butylu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"octanu etylu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\nbutan-2-onu (metyloetyloketon)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nchloroformu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ncykloheksanu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ncykloheksanolu\nZakres (0,50– 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ncykloheksanonu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ndisiarczku węgla\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\netylobenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\n4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nizopropylobenzenu (kumenu)\nZakres (0,5 – 100) mg/m3\nZakres (0,010– 2,0) mg w próbce\nksylenu\nZakres (0,05 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\n4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\n2-metylopropan-1-olu (alkoholu izobutylowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nmezytylenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 5,0) mg w próbce\noctanu butylu\nZakres (0,50 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu etylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\nbutan-2-onu (metyloetyloketon)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nchloroformu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ncykloheksanu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ncykloheksanolu\nZakres (0,50– 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\ncykloheksanonu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ndisiarczku węgla\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\netylobenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\n4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nizopropylobenzenu (kumenu)\nZakres (0,5 – 100) mg/m3\nZakres (0,010– 2,0) mg w próbce\nksylenu\nZakres (0,05 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\n4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\n2-metylopropan-1-olu (alkoholu izobutylowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nmezytylenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 5,0) mg w próbce\noctanu butylu\nZakres (0,50 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\noctanu etylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Stezenie / zawartosc indywidualnych gazowych zwiazkow organicznych\nZakres:\nbutan-2-onu (metyloetyloketon)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nchloroformu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\ncykloheksanu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\ncykloheksanolu\nZakres (0,50– 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\ncykloheksanonu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\ndisiarczku wegla\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\netylobenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\n4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nizopropylobenzenu (kumenu)\nZakres (0,5 – 100) mg/m3\nZakres (0,010– 2,0) mg w probce\nksylenu\nZakres (0,05 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\n4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\n2-metylopropan-1-olu (alkoholu izobutylowego)\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nmezytylenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 5,0) mg w probce\noctanu butylu\nZakres (0,50 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\noctanu etylu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":189,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of individual gaseous organic compounds","parameters_en":[{"name":"butan-2-one (methyl ethyl ketone)"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"chloroform"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"cyclohexane"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"cyclohexanol"},{"name":"Range","range":"(0,50– 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"cyclohexanone"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"carbon disulphide"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"ethylbenzene"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"4-hydroxy-4-methylpentan-2-one (diacetone alcohol)"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"isopropylbenzene (cumene)"},{"name":"Range","range":"(0,5 – 100) mg/m3"},{"name":"Range","range":"(0,010– 2,0) mg w próbce"},{"name":"xylene"},{"name":"Range","range":"(0,05 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"4-methylpentan-2-one (methyl isobutyl ketone, hexone)"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"2-methylpropan-1-ol (isobutyl alcohol)"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"mesitylene"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 5,0) mg w próbce"},{"name":"butyl acetate"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"ethyl acetate"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into sorbent tubes Concentration / content of individual gaseous organic compounds Gas chromatography with flame ionization detection (GC-FID) butan-2-one (methyl ethyl ketone) Range Range chloroform Range Range cyclohexane Range Range cyclohexanol Range Range cyclohexanone Range Range carbon disulphide Range Range ethylbenzene Range Range 4-hydroxy-4-methylpentan-2-one (diacetone alcohol) Range Range isopropylbenzene (cumene) Range Range xylene Range Range 4-methylpentan-2-one (methyl isobutyl ketone, hexone) Range Range 2-methylpropan-1-ol (isobutyl alcohol) Range Range mesitylene Range Range butyl acetate Range Range ethyl acetate Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","parameters_zh":[{"name":"butan-2-onu (metyloetyloketon)"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"chloroformu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"环己烷"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"cykloheksanolu"},{"name":"范围","range":"(0,50– 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"环己酮"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"disiarczku węgla"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"乙苯"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"4-hydroksy-4-metylopentan-2-onu (alkoholu dwuacetonowego)"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"izopropylobenzenu (kumenu)"},{"name":"范围","range":"(0,5 – 100) mg/m3"},{"name":"范围","range":"(0,010– 2,0) mg w próbce"},{"name":"ksylenu"},{"name":"范围","range":"(0,05 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"4-metylopentan-2-onu (metyloizobutyloketonu, heksonu)"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"2-metylopropan-1-olu (alkoholu izobutylowego)"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"mezytylenu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 5,0) mg w próbce"},{"name":"octanu butylu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"乙酸乙酯"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"}],"search_zh":"排放气体 － 采集于吸附管中的排放气体样品 单个气态有机化合物的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 环己烷 范围 范围 范围 范围 环己酮 范围 范围 范围 范围 乙苯 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 范围 乙酸乙酯 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品","methodology_zh":"单个气态有机化合物的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20441","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Stężenie / zawartość indywidualnych gazowych związków organicznych","parameters":[{"name":"octanu winylu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"prop-2-en-1-olu (alkoholu allilowego)"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"propylobenzenu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"trietyloaminy"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 2,0) mg w próbce"},{"name":"styrenu"},{"name":"Zakres","range":"(0,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,010 – 1,0) mg w próbce"},{"name":"toluenu"},{"name":"Zakres","range":"(0,050 – 100) mg/m3"},{"name":"Zakres","range":"(0,0010 – 2,0) mg w próbce"},{"name":"metanolu"},{"name":"Zakres","range":"(0,250 – 250) mg/m3"},{"name":"Zakres","range":"(0,0050 – 5,0) mg w próbce fenolu"},{"name":"Zakres","range":"(0,250 – 50) mg/m3"},{"name":"Zakres","range":"(0,0050 – 1,0) mg w próbce"},{"name":"acetaldehydu"},{"name":"Zakres","range":"(0,05 – 100) mg/m3"},{"name":"Zakres","range":"(0,001 – 2,0) mg w próbce"},{"name":"formaldehydu"},{"name":"Zakres","range":"(0,050 – 50) mg/m3"},{"name":"Zakres","range":"(0,0010 – 1,0) mg w próbce"},{"name":"kwasu octowego"},{"name":"Zakres","range":"(0,250 – 100) mg/m3"},{"name":"Zakres","range":"(0,0050 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\noctanu winylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nprop-2-en-1-olu (alkoholu allilowego)\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\npropylobenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ntrietyloaminy\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nstyrenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 1,0) mg w próbce\ntoluenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nmetanolu\nZakres (0,250 – 250) mg/m3\nZakres (0,0050 – 5,0) mg w próbce fenolu\nZakres (0,250 – 50) mg/m3\nZakres (0,0050 – 1,0) mg w próbce\nacetaldehydu\nZakres (0,05 – 100) mg/m3\nZakres (0,001 – 2,0) mg w próbce\nformaldehydu\nZakres (0,050 – 50) mg/m3\nZakres (0,0010 – 1,0) mg w próbce\nkwasu octowego\nZakres (0,250 – 100) mg/m3\nZakres (0,0050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Stężenie / zawartość indywidualnych gazowych związków organicznych\nZakres:\noctanu winylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nprop-2-en-1-olu (alkoholu allilowego)\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\npropylobenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\ntrietyloaminy\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w próbce\nstyrenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 1,0) mg w próbce\ntoluenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w próbce\nmetanolu\nZakres (0,250 – 250) mg/m3\nZakres (0,0050 – 5,0) mg w próbce fenolu\nZakres (0,250 – 50) mg/m3\nZakres (0,0050 – 1,0) mg w próbce\nacetaldehydu\nZakres (0,05 – 100) mg/m3\nZakres (0,001 – 2,0) mg w próbce\nformaldehydu\nZakres (0,050 – 50) mg/m3\nZakres (0,0010 – 1,0) mg w próbce\nkwasu octowego\nZakres (0,250 – 100) mg/m3\nZakres (0,0050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Stezenie / zawartosc indywidualnych gazowych zwiazkow organicznych\nZakres:\noctanu winylu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nprop-2-en-1-olu (alkoholu allilowego)\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\npropylobenzenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\ntrietyloaminy\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 2,0) mg w probce\nstyrenu\nZakres (0,50 – 100) mg/m3\nZakres (0,010 – 1,0) mg w probce\ntoluenu\nZakres (0,050 – 100) mg/m3\nZakres (0,0010 – 2,0) mg w probce\nmetanolu\nZakres (0,250 – 250) mg/m3\nZakres (0,0050 – 5,0) mg w probce fenolu\nZakres (0,250 – 50) mg/m3\nZakres (0,0050 – 1,0) mg w probce\nacetaldehydu\nZakres (0,05 – 100) mg/m3\nZakres (0,001 – 2,0) mg w probce\nformaldehydu\nZakres (0,050 – 50) mg/m3\nZakres (0,0010 – 1,0) mg w probce\nkwasu octowego\nZakres (0,250 – 100) mg/m3\nZakres (0,0050 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":190,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of individual gaseous organic compounds","parameters_en":[{"name":"vinyl acetate"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"prop-2-en-1-ol (allyl alcohol)"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"propylbenzene"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"triethylamine"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 2,0) mg w próbce"},{"name":"styrene"},{"name":"Range","range":"(0,50 – 100) mg/m3"},{"name":"Range","range":"(0,010 – 1,0) mg w próbce"},{"name":"toluene"},{"name":"Range","range":"(0,050 – 100) mg/m3"},{"name":"Range","range":"(0,0010 – 2,0) mg w próbce"},{"name":"methanol"},{"name":"Range","range":"(0,250 – 250) mg/m3"},{"name":"Range","range":"(0,0050 – 5,0) mg w próbce fenolu"},{"name":"Range","range":"(0,250 – 50) mg/m3"},{"name":"Range","range":"(0,0050 – 1,0) mg w próbce"},{"name":"acetaldehyde"},{"name":"Range","range":"(0,05 – 100) mg/m3"},{"name":"Range","range":"(0,001 – 2,0) mg w próbce"},{"name":"formaldehyde"},{"name":"Range","range":"(0,050 – 50) mg/m3"},{"name":"Range","range":"(0,0010 – 1,0) mg w próbce"},{"name":"acetic acid"},{"name":"Range","range":"(0,250 – 100) mg/m3"},{"name":"Range","range":"(0,0050 – 2,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into sorbent tubes Concentration / content of individual gaseous organic compounds Gas chromatography with flame ionization detection (GC-FID) vinyl acetate Range Range prop-2-en-1-ol (allyl alcohol) Range Range propylbenzene Range Range triethylamine Range Range styrene Range Range toluene Range Range methanol Range Range Range Range acetaldehyde Range Range formaldehyde Range Range acetic acid Range Range PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","parameters_zh":[{"name":"octanu winylu"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"prop-2-en-1-olu (alkoholu allilowego)"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"propylobenzenu"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"trietyloaminy"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 2,0) mg w próbce"},{"name":"苯乙烯"},{"name":"范围","range":"(0,50 – 100) mg/m3"},{"name":"范围","range":"(0,010 – 1,0) mg w próbce"},{"name":"甲苯"},{"name":"范围","range":"(0,050 – 100) mg/m3"},{"name":"范围","range":"(0,0010 – 2,0) mg w próbce"},{"name":"metanolu"},{"name":"范围","range":"(0,250 – 250) mg/m3"},{"name":"范围","range":"(0,0050 – 5,0) mg w próbce fenolu"},{"name":"范围","range":"(0,250 – 50) mg/m3"},{"name":"范围","range":"(0,0050 – 1,0) mg w próbce"},{"name":"acetaldehydu"},{"name":"范围","range":"(0,05 – 100) mg/m3"},{"name":"范围","range":"(0,001 – 2,0) mg w próbce"},{"name":"甲醛"},{"name":"范围","range":"(0,050 – 50) mg/m3"},{"name":"范围","range":"(0,0010 – 1,0) mg w próbce"},{"name":"kwasu octowego"},{"name":"范围","range":"(0,250 – 100) mg/m3"},{"name":"范围","range":"(0,0050 – 2,0) mg w próbce"}],"search_zh":"排放气体 － 采集于吸附管中的排放气体样品 单个气态有机化合物的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 范围 范围 范围 范围 范围 范围 苯乙烯 范围 范围 甲苯 范围 范围 范围 范围 范围 范围 范围 范围 甲醛 范围 范围 范围 范围 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品","methodology_zh":"单个气态有机化合物的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20442","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Emisja indywidualnych gazowych związków organicznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":191,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of individual gaseous organic compounds (calculated)","search_en":"Waste gases – waste gas samples collected into sorbent tubes Emission of individual gaseous organic compounds (calculated) PN-EN 13649:2005","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","methodology_zh":"单项气态有机化合物排放量（计算值）","search_zh":"排放气体 － 采集于吸附管中的排放气体样品 单项气态有机化合物排放量（计算值） PN-EN 13649:2005","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20443","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Pobieranie próbek do oznaczania stężenia węglowodorów alifatycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia węglowodorów alifatycznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Pobieranie próbek do oznaczania stężenia węglowodorów alifatycznych PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Pobieranie probek do oznaczania stezenia weglowodorow alifatycznych PN-EN 13649:2005","categories":["other"],"row_index":192,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of aliphatic hydrocarbons","search_en":"Waste gases – waste gas samples collected into sorbent tubes Sampling for determination of the concentration of aliphatic hydrocarbons PN-EN 13649:2005","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","search_zh":"排放气体 － 采集于吸附管中的排放气体样品 PN-EN 13649:2005","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20444","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Stężenie / zawartość węglowodorów alifatycznych (C5-C12)","parameters":[{"name":"pentan"},{"name":"Zakres","range":"(0,05 – 250) mg/m3"},{"name":"Zakres","range":"(0,001 – 5,0) mg w próbce"},{"name":"heksan","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce"},{"name":"heptan","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce"},{"name":"oktan","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce"},{"name":"nonan","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce"},{"name":"dekan","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce"},{"name":"undekan","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce"},{"name":"dodekan","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce Suma węglowodorów alifatycznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość węglowodorów alifatycznych (C5-C12)\nZakres:\npentan\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nheksan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\nheptan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\noktan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\nnonan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\ndekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\nundekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\ndodekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce Suma węglowodorów alifatycznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Stężenie / zawartość węglowodorów alifatycznych (C5-C12)\nZakres:\npentan\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w próbce\nheksan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\nheptan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\noktan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\nnonan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\ndekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\nundekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce\ndodekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w próbce Suma węglowodorów alifatycznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Stezenie / zawartosc weglowodorow alifatycznych (C5-C12)\nZakres:\npentan\nZakres (0,05 – 250) mg/m3\nZakres (0,001 – 5,0) mg w probce\nheksan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w probce\nheptan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w probce\noktan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w probce\nnonan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w probce\ndekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w probce\nundekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w probce\ndodekan (0,05 – 250) mg/m3\n(0,001 – 5,0) mg w probce Suma weglowodorow alifatycznych (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":193,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of aliphatic hydrocarbons (C5-C12)","parameters_en":[{"name":"pentane"},{"name":"Range","range":"(0,05 – 250) mg/m3"},{"name":"Range","range":"(0,001 – 5,0) mg w próbce"},{"name":"hexane","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg in the sample"},{"name":"heptane","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg in the sample"},{"name":"octane","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg in the sample"},{"name":"nonane","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg in the sample"},{"name":"decane","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg in the sample"},{"name":"undecane","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg in the sample"},{"name":"dodecane","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg in the sample Sum of aliphatic hydrocarbons (calculated)"}],"search_en":"Waste gases – waste gas samples collected into sorbent tubes Concentration / content of aliphatic hydrocarbons (C5-C12) Gas chromatography with flame ionization detection (GC-FID) pentane Range Range hexane (0,001 – 5,0) mg in the sample heptane (0,001 – 5,0) mg in the sample octane (0,001 – 5,0) mg in the sample nonane (0,001 – 5,0) mg in the sample decane (0,001 – 5,0) mg in the sample undecane (0,001 – 5,0) mg in the sample dodecane (0,001 – 5,0) mg in the sample Sum of aliphatic hydrocarbons (calculated) PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","parameters_zh":[{"name":"戊烷"},{"name":"范围","range":"(0,05 – 250) mg/m3"},{"name":"范围","range":"(0,001 – 5,0) mg w próbce"},{"name":"正己烷","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg/样品"},{"name":"正庚烷","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg/样品"},{"name":"辛烷","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg/样品"},{"name":"壬烷","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg/样品"},{"name":"癸烷","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg/样品"},{"name":"十一烷","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg/样品"},{"name":"十二烷","range":"(0,05 – 250) mg/m3"},{"name":"(0,001 – 5,0) mg w próbce Suma węglowodorów alifatycznych (z obliczeń)"}],"search_zh":"排放气体 － 采集于吸附管中的排放气体样品 气相色谱-氢火焰离子化检测法（GC-FID） 戊烷 范围 范围 正己烷 (0,001 – 5,0) mg/样品 正庚烷 (0,001 – 5,0) mg/样品 辛烷 (0,001 – 5,0) mg/样品 壬烷 (0,001 – 5,0) mg/样品 癸烷 (0,001 – 5,0) mg/样品 十一烷 (0,001 – 5,0) mg/样品 十二烷 PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20445","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Emisja węglowodorów alifatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja węglowodorów alifatycznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Emisja węglowodorów alifatycznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Emisja weglowodorow alifatycznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":194,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of aliphatic hydrocarbons (calculated)","search_en":"Waste gases – waste gas samples collected into sorbent tubes Emission of aliphatic hydrocarbons (calculated) PN-EN 13649:2005","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","search_zh":"排放气体 － 采集于吸附管中的排放气体样品 PN-EN 13649:2005","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20446","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Pobieranie próbek do oznaczania stężenia węglowodorów aromatycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia węglowodorów aromatycznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Pobieranie próbek do oznaczania stężenia węglowodorów aromatycznych PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Pobieranie probek do oznaczania stezenia weglowodorow aromatycznych PN-EN 13649:2005","categories":["other"],"row_index":195,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of aromatic hydrocarbons","search_en":"Waste gases – waste gas samples collected into sorbent tubes Sampling for determination of the concentration of aromatic hydrocarbons PN-EN 13649:2005","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","search_zh":"排放气体 － 采集于吸附管中的排放气体样品 PN-EN 13649:2005","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20447","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Stężenie / zawartość węglowodorów aromatycznych (C6-C10)","parameters":[{"name":"1,2,4-trimetylobenzen"},{"name":"Zakres","range":"(0,050 – 50) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"},{"name":"1,4-dietylobenzen"},{"name":"Zakres","range":"(0,050 – 50) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"},{"name":"1,2-dietylobenzen"},{"name":"Zakres","range":"(0,050 – 50) mg/m3"},{"name":"Zakres","range":"(0,001 – 1,0) mg w próbce"},{"name":"Suma węglowodorów aromatycznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie / zawartość węglowodorów aromatycznych (C6-C10)\nZakres:\n1,2,4-trimetylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\n1,4-dietylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\n1,2-dietylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nSuma węglowodorów aromatycznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Stężenie / zawartość węglowodorów aromatycznych (C6-C10)\nZakres:\n1,2,4-trimetylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\n1,4-dietylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\n1,2-dietylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w próbce\nSuma węglowodorów aromatycznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Stezenie / zawartosc weglowodorow aromatycznych (C6-C10)\nZakres:\n1,2,4-trimetylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w probce\n1,4-dietylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w probce\n1,2-dietylobenzen\nZakres (0,050 – 50) mg/m3\nZakres (0,001 – 1,0) mg w probce\nSuma weglowodorow aromatycznych (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN 13649:2005","categories":["other"],"row_index":196,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of aromatic hydrocarbons (C6-C10)","parameters_en":[{"name":"1,2,4-trimethylbenzene"},{"name":"Range","range":"(0,050 – 50) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"},{"name":"1,4-diethylbenzene"},{"name":"Range","range":"(0,050 – 50) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"},{"name":"1,2-diethylbenzene"},{"name":"Range","range":"(0,050 – 50) mg/m3"},{"name":"Range","range":"(0,001 – 1,0) mg w próbce"},{"name":"Sum of aromatic hydrocarbons (calculated)"}],"search_en":"Waste gases – waste gas samples collected into sorbent tubes Concentration / content of aromatic hydrocarbons (C6-C10) Gas chromatography with flame ionization detection (GC-FID) 1,2,4-trimethylbenzene Range Range 1,4-diethylbenzene Range Range 1,2-diethylbenzene Range Range Sum of aromatic hydrocarbons (calculated) PN-EN 13649:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","parameters_zh":[{"name":"1,2,4-三甲苯"},{"name":"范围","range":"(0,050 – 50) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"},{"name":"1,4-dietylobenzen"},{"name":"范围","range":"(0,050 – 50) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"},{"name":"1,2-dietylobenzen"},{"name":"范围","range":"(0,050 – 50) mg/m3"},{"name":"范围","range":"(0,001 – 1,0) mg w próbce"},{"name":"芳香烃总量（由计算得出）"}],"search_zh":"排放气体 － 采集于吸附管中的排放气体样品 气相色谱-氢火焰离子化检测法（GC-FID） 1,2,4-三甲苯 范围 范围 范围 范围 范围 范围 芳香烃总量（由计算得出） PN-EN 13649:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20448","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem","methodology":"Emisja węglowodorów aromatycznych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja węglowodorów aromatycznych (z obliczeń)","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do rurek z sorbentem Emisja węglowodorów aromatycznych (z obliczeń) PN-EN 13649:2005 Gazy odlotowe – probki gazow odlotowych pobranych do rurek z sorbentem Emisja weglowodorow aromatycznych (z obliczen) PN-EN 13649:2005","categories":["environment"],"row_index":197,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of aromatic hydrocarbons (calculated)","search_en":"Waste gases – waste gas samples collected into sorbent tubes Emission of aromatic hydrocarbons (calculated) PN-EN 13649:2005","test_object_en":"Waste gases – waste gas samples collected into sorbent tubes","search_zh":"排放气体 － 采集于吸附管中的排放气体样品 PN-EN 13649:2005","test_object_zh":"排放气体 － 采集于吸附管中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20449","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia pyłu PM10, PM2,5","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu PM10, PM2,5","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PM10, PM2,5 PN-EN ISO 23210:2010 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PM10, PM2,5 PN-EN ISO 23210:2010","categories":["other"],"row_index":198,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of PM10, PM2,5 dust","search_en":"Waste gases Sampling for determination of the concentration of PM10, PM2,5 dust PN-EN ISO 23210:2010","test_object_en":"Waste gases","search_zh":"废气 PN-EN ISO 23210:2010","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b2044a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu PM10, PM 2,5","parameters":[{"name":"Zakres","range":"(0,40 – 40) mg/m3"}],"technique":"Metoda grawimetryczna (impaktorowa)","techniques":["Metoda grawimetryczna (impaktorowa)"],"computed":[],"activity":"Stężenie pyłu PM10, PM 2,5\nZakres (0,40 – 40) mg/m3\nMetoda grawimetryczna (impaktorowa)","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu PM10, PM 2,5\nZakres (0,40 – 40) mg/m3\nMetoda grawimetryczna (impaktorowa) PN-EN ISO 23210:2010 Gazy odlotowe Stezenie pylu PM10, PM 2,5\nZakres (0,40 – 40) mg/m3\nMetoda grawimetryczna (impaktorowa) PN-EN ISO 23210:2010","categories":["other"],"row_index":199,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PM10, PM 2,5 dust concentration","parameters_en":[{"name":"Range","range":"(0,40 – 40) mg/m3"}],"search_en":"Waste gases PM10, PM 2,5 dust concentration Gravimetric method (impactor) Range PN-EN ISO 23210:2010","technique_en":"Gravimetric method (impactor)","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,40 – 40) mg/m3"}],"search_zh":"废气 范围 PN-EN ISO 23210:2010","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b2044b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu PM10, PM2,5 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu PM10, PM2,5 (z obliczeń)","reference":"PN-EN ISO 23210:2010","norm_bases":["PN-EN ISO 23210:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja pyłu PM10, PM2,5 (z obliczeń) PN-EN ISO 23210:2010 Gazy odlotowe Emisja pylu PM10, PM2,5 (z obliczen) PN-EN ISO 23210:2010","categories":["environment"],"row_index":200,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PM10, PM2,5 dust emission (calculated)","search_en":"Waste gases PM10, PM2,5 dust emission (calculated) PN-EN ISO 23210:2010","test_object_en":"Waste gases","search_zh":"废气 PM10、PM2,5 粉尘排放（由计算得出） PN-EN ISO 23210:2010","test_object_zh":"废气","methodology_zh":"PM10、PM2,5 粉尘排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b2044c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do analizy granulometrycznej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do analizy granulometrycznej","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do analizy granulometrycznej PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek pylu do analizy granulometrycznej PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["other"],"row_index":201,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for particle size analysis","search_en":"Waste gases Dust sampling for particle size analysis PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 用于粒度分析的粉尘采样 PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"用于粒度分析的粉尘采样"},{"_id":"6a83ae76af14b9c0e7b2044d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja frakcji pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja frakcji pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","norm_bases":["PN-Z-04030-7:1994","PN-EN 13284-1:2018-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja frakcji pyłu (z obliczeń) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02 Gazy odlotowe Emisja frakcji pylu (z obliczen) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","categories":["environment"],"row_index":202,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of the dust fraction (calculated)","search_en":"Waste gases Emission of the dust fraction (calculated) PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘分级排放（由计算得出） PN-Z-04030-7:1994 | PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘分级排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b2044e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczenia stężenia związków organicznych, podtlenku azotu, tlenu, dwutlenku węgla, tlenku węgla, azotu, siarkowodoru.","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem worka tedlarowego.","techniques":["Metoda aspiracyjna z zastosowaniem worka tedlarowego."],"computed":[],"activity":"Pobieranie próbek do oznaczenia stężenia związków organicznych, podtlenku azotu, tlenu, dwutlenku węgla, tlenku węgla, azotu, siarkowodoru.\nMetoda aspiracyjna z zastosowaniem worka tedlarowego.","reference":"PB-109/W4-01.06.2026","norm_bases":["PB-109/W4-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczenia stężenia związków organicznych, podtlenku azotu, tlenu, dwutlenku węgla, tlenku węgla, azotu, siarkowodoru.\nMetoda aspiracyjna z zastosowaniem worka tedlarowego. PB-109/W4-01.06.2026 Gazy odlotowe Pobieranie probek do oznaczenia stezenia zwiazkow organicznych, podtlenku azotu, tlenu, dwutlenku wegla, tlenku wegla, azotu, siarkowodoru.\nMetoda aspiracyjna z zastosowaniem worka tedlarowego. PB-109/W4-01.06.2026","categories":["other"],"row_index":203,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of organic compounds, nitrous oxide, oxygen, carbon dioxide, carbon monoxide, nitrogen, hydrogen sulfide.","search_en":"Waste gases Sampling for determination of the concentration of organic compounds, nitrous oxide, oxygen, carbon dioxide, carbon monoxide, nitrogen, hydrogen sulfide. Aspiration method using a Tedlar bag. PB-109/W4-01.06.2026","technique_en":"Aspiration method using a Tedlar bag.","test_object_en":"Waste gases","search_zh":"废气 PB-109/W4-01.06.2026","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b2044f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja związków organicznych, podtlenku azotu, tlenu, dwutlenku węgla, tlenku węgla, azotu, siarkowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja związków organicznych, podtlenku azotu, tlenu, dwutlenku węgla, tlenku węgla, azotu, siarkowodoru (z obliczeń)","reference":"PB-109/W4-01.06.2026","norm_bases":["PB-109/W4-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja związków organicznych, podtlenku azotu, tlenu, dwutlenku węgla, tlenku węgla, azotu, siarkowodoru (z obliczeń) PB-109/W4-01.06.2026 Gazy odlotowe Emisja zwiazkow organicznych, podtlenku azotu, tlenu, dwutlenku wegla, tlenku wegla, azotu, siarkowodoru (z obliczen) PB-109/W4-01.06.2026","categories":["environment"],"row_index":204,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of organic compounds, nitrous oxide, oxygen, carbon dioxide, carbon monoxide, nitrogen, hydrogen sulphide (calculated)","search_en":"Waste gases Emission of organic compounds, nitrous oxide, oxygen, carbon dioxide, carbon monoxide, nitrogen, hydrogen sulphide (calculated) PB-109/W4-01.06.2026","test_object_en":"Waste gases","search_zh":"废气 PB-109/W4-01.06.2026","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b20450","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenu","parameters":[{"name":"O2","range":"(0,5 – 21) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu\nO2 (0,5 – 21) %\nMetoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie tlenu\nO2 (0,5 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu\nO2 (0,5 – 21) %\nMetoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":205,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen concentration","parameters_en":[{"name":"O2","range":"(0,5 – 21) %"}],"search_en":"Waste gases Oxygen concentration Electrochemical method O2 PN-ISO 10396:2001","technique_en":"Electrochemical method","test_object_en":"Waste gases","search_zh":"废气 氧浓度 电化学法 O2 PN-ISO 10396:2001","technique_zh":"电化学法","test_object_zh":"废气","parameters_zh":[{"name":"O2","range":"(0,5 – 21) %"}],"methodology_zh":"氧浓度"},{"_id":"6a83ae76af14b9c0e7b20451","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja O2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja O2 (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja O2 (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja O2 (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":206,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"O2 emission (calculated)","search_en":"Waste gases O2 emission (calculated) PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a83ae76af14b9c0e7b20452","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie podtlenku azotu","parameters":[{"name":"N2O","range":"(4 – 700) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie podtlenku azotu\nN2O (4 – 700) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie podtlenku azotu\nN2O (4 – 700) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Gazy odlotowe Stezenie podtlenku azotu\nN2O (4 – 700) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":207,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrous oxide concentration","parameters_en":[{"name":"N2O","range":"(4 – 700) mg/m3"}],"search_en":"Waste gases Nitrous oxide concentration Non-dispersive infrared spectrometry (NDIR) N2O PN-EN ISO 21258:2010","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Waste gases","search_zh":"废气 一氧化二氮浓度 非分散红外光谱法（NDIR） PN-EN ISO 21258:2010","test_object_zh":"废气","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"一氧化二氮浓度"},{"_id":"6a83ae76af14b9c0e7b20453","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja N2O (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja N2O (z obliczeń)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja N2O (z obliczeń) PN-EN ISO 21258:2010 Gazy odlotowe Emisja N2O (z obliczen) PN-EN ISO 21258:2010","categories":["environment"],"row_index":208,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"N2O emission (calculated)","search_en":"Waste gases N2O emission (calculated) PN-EN ISO 21258:2010","test_object_en":"Waste gases","search_zh":"废气 N2O 排放（由计算得出） PN-EN ISO 21258:2010","test_object_zh":"废气","methodology_zh":"N2O 排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20454","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia fluoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluoru","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia fluoru PB-33/W11-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia fluoru PB-33/W11-01.06.2026","categories":["other"],"row_index":209,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of fluorine concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for the determination of fluorine concentration PB-33/W11-01.06.2026","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 用于测定氟浓度的采样 PB-33/W11-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"用于测定氟浓度的采样"},{"_id":"6a83ae76af14b9c0e7b20455","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie fluoru (0,09 – 60) mg/m3 (0,01 – 10) mg w próbce","parameters":[],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluoru (0,09 – 60) mg/m3 (0,01 – 10) mg w próbce\nMetoda potencjometryczna","reference":"PB-27/W8-29.03.2021","norm_bases":["PB-27/W8-29.03.2021"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie fluoru (0,09 – 60) mg/m3 (0,01 – 10) mg w próbce\nMetoda potencjometryczna PB-27/W8-29.03.2021 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie fluoru (0,09 – 60) mg/m3 (0,01 – 10) mg w probce\nMetoda potencjometryczna PB-27/W8-29.03.2021","categories":["other"],"row_index":210,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine concentration (0,09 – 60) mg/m3 (0,01 – 10) mg in the sample","search_en":"Waste gases – waste gas samples collected into absorbing solution Fluorine concentration (0,09 – 60) mg/m3 (0,01 – 10) mg in the sample Potentiometric method PB-27/W8-29.03.2021","technique_en":"Potentiometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 电位法 PB-27/W8-29.03.2021","technique_zh":"电位法","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b20456","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja fluoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fluoru (z obliczeń)","reference":"PB-27/W8-29.03.2021","norm_bases":["PB-27/W8-29.03.2021"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja fluoru (z obliczeń) PB-27/W8-29.03.2021 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja fluoru (z obliczen) PB-27/W8-29.03.2021","categories":["environment"],"row_index":211,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Fluorine emission (calculated) PB-27/W8-29.03.2021","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 氟排放（由计算得出） PB-27/W8-29.03.2021","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氟排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20457","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania, Stężenia dwutlenku siarki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania, Stężenia dwutlenku siarki","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania, Stężenia dwutlenku siarki PB-33/W11-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania, Stezenia dwutlenku siarki PB-33/W11-01.06.2026","categories":["other"],"row_index":212,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of, Sulfur dioxide concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of, Sulfur dioxide concentration PB-33/W11-01.06.2026","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 PB-33/W11-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b20458","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość dwutlenku siarki","parameters":[{"name":"Zakres","range":"(0,05 – 32) mg/m3"},{"name":"Zakres","range":"(0,0008 – 1,6) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość dwutlenku siarki\nZakres:\nZakres (0,05 – 32) mg/m3\nZakres (0,0008 – 1,6) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-65/W5-17.03.2016","norm_bases":["PB-65/W5-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość dwutlenku siarki\nZakres:\nZakres (0,05 – 32) mg/m3\nZakres (0,0008 – 1,6) mg w próbce\nMetoda spektrofotometryczna PB-65/W5-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc dwutlenku siarki\nZakres:\nZakres (0,05 – 32) mg/m3\nZakres (0,0008 – 1,6) mg w probce\nMetoda spektrofotometryczna PB-65/W5-17.03.2016","categories":["other"],"row_index":213,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulphur dioxide","parameters_en":[{"name":"Range","range":"(0,05 – 32) mg/m3"},{"name":"Range","range":"(0,0008 – 1,6) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Concentration / content of sulphur dioxide Spectrophotometric method Range Range PB-65/W5-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,05 – 32) mg/m3"},{"name":"范围","range":"(0,0008 – 1,6) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 分光光度法 范围 范围 PB-65/W5-17.03.2016","technique_zh":"分光光度法","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b20459","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja dwutlenku siarki (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja dwutlenku siarki (z obliczeń)","reference":"PB-65/W5-17.03.2016","norm_bases":["PB-65/W5-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja dwutlenku siarki (z obliczeń) PB-65/W5-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja dwutlenku siarki (z obliczen) PB-65/W5-17.03.2016","categories":["environment"],"row_index":214,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphur dioxide emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Sulphur dioxide emission (calculated) PB-65/W5-17.03.2016","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 二氧化硫排放（由计算得出） PB-65/W5-17.03.2016","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"二氧化硫排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b2045a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia trójtlenku siarki","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia trójtlenku siarki","reference":"PB-94/W5-01.06.2026","norm_bases":["PB-94/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia trójtlenku siarki PB-94/W5-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia trojtlenku siarki PB-94/W5-01.06.2026","categories":["other"],"row_index":215,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of sulfur trioxide concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of sulfur trioxide concentration PB-94/W5-01.06.2026","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 PB-94/W5-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b2045b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość trójtlenku siarki","parameters":[{"name":"Zakres","range":"(2,0 – 40) mg/m3"},{"name":"Zakres","range":"(2,0 – 20,0) mg w próbce"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie / zawartość trójtlenku siarki\nZakres:\nZakres (2,0 – 40) mg/m3\nZakres (2,0 – 20,0) mg w próbce\nMetoda toronowa","reference":"PB-95/W3-22.06.2012","norm_bases":["PB-95/W3-22.06.2012"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość trójtlenku siarki\nZakres:\nZakres (2,0 – 40) mg/m3\nZakres (2,0 – 20,0) mg w próbce\nMetoda toronowa PB-95/W3-22.06.2012 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc trojtlenku siarki\nZakres:\nZakres (2,0 – 40) mg/m3\nZakres (2,0 – 20,0) mg w probce\nMetoda toronowa PB-95/W3-22.06.2012","categories":["other"],"row_index":216,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulfur trioxide","parameters_en":[{"name":"Range","range":"(2,0 – 40) mg/m3"},{"name":"Range","range":"(2,0 – 20,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Concentration / content of sulfur trioxide Thoron method Range Range PB-95/W3-22.06.2012","technique_en":"Thoron method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(2,0 – 40) mg/m3"},{"name":"范围","range":"(2,0 – 20,0) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 钍射气法 范围 范围 PB-95/W3-22.06.2012","technique_zh":"钍射气法","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b2045c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja trójtlenku siarki (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja trójtlenku siarki (z obliczeń)","reference":"PB-95/W3-22.06.2012","norm_bases":["PB-95/W3-22.06.2012"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja trójtlenku siarki (z obliczeń) PB-95/W3-22.06.2012 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja trojtlenku siarki (z obliczen) PB-95/W3-22.06.2012","categories":["environment"],"row_index":217,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of sulphur trioxide (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Emission of sulphur trioxide (calculated) PB-95/W3-22.06.2012","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 PB-95/W3-22.06.2012","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b2045d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia siarkowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia siarkowodoru","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia siarkowodoru PB-33/W11-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia siarkowodoru PB-33/W11-01.06.2026","categories":["other"],"row_index":218,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen sulphide concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of hydrogen sulphide concentration PB-33/W11-01.06.2026","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 用于测定硫化氢浓度的采样 PB-33/W11-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"用于测定硫化氢浓度的采样"},{"_id":"6a83ae76af14b9c0e7b2045e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,5 – 80) mg/m3"},{"name":"Zakres","range":"(0,01 – 2,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość siarkowodoru\nZakres:\nZakres (0,5 – 80) mg/m3\nZakres (0,01 – 2,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-66/W3-17.03.2016","norm_bases":["PB-66/W3-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość siarkowodoru\nZakres:\nZakres (0,5 – 80) mg/m3\nZakres (0,01 – 2,0) mg w próbce\nMetoda spektrofotometryczna PB-66/W3-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc siarkowodoru\nZakres:\nZakres (0,5 – 80) mg/m3\nZakres (0,01 – 2,0) mg w probce\nMetoda spektrofotometryczna PB-66/W3-17.03.2016","categories":["other"],"row_index":219,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide concentration / content","parameters_en":[{"name":"Range","range":"(0,5 – 80) mg/m3"},{"name":"Range","range":"(0,01 – 2,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Hydrogen sulphide concentration / content Spectrophotometric method Range Range PB-66/W3-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,5 – 80) mg/m3"},{"name":"范围","range":"(0,01 – 2,0) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 硫化氢的浓度/含量 分光光度法 范围 范围 PB-66/W3-17.03.2016","technique_zh":"分光光度法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"硫化氢的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b2045f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja siarkowodoru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja siarkowodoru (z obliczeń)","reference":"PB-66/W3-17.03.2016","norm_bases":["PB-66/W3-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja siarkowodoru (z obliczeń) PB-66/W3-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja siarkowodoru (z obliczen) PB-66/W3-17.03.2016","categories":["environment"],"row_index":220,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen sulphide emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Hydrogen sulphide emission (calculated) PB-66/W3-17.03.2016","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 硫化氢排放（由计算得出） PB-66/W3-17.03.2016","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"硫化氢排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20460","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia chloru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chloru","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia chloru PB-33/W11-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia chloru PB-33/W11-01.06.2026","categories":["other"],"row_index":221,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of chlorine concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for the determination of chlorine concentration PB-33/W11-01.06.2026","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 用于测定氯浓度的采样 PB-33/W11-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"用于测定氯浓度的采样"},{"_id":"6a83ae76af14b9c0e7b20461","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość chloru","parameters":[{"name":"Zakres","range":"(0,1 – 1,6) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,032) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość chloru\nZakres:\nZakres (0,1 – 1,6) mg/m3\nZakres (0,001 – 0,032) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-58/W6-17.03.2016","norm_bases":["PB-58/W6-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość chloru\nZakres:\nZakres (0,1 – 1,6) mg/m3\nZakres (0,001 – 0,032) mg w próbce\nMetoda spektrofotometryczna PB-58/W6-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc chloru\nZakres:\nZakres (0,1 – 1,6) mg/m3\nZakres (0,001 – 0,032) mg w probce\nMetoda spektrofotometryczna PB-58/W6-17.03.2016","categories":["other"],"row_index":222,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration / content","parameters_en":[{"name":"Range","range":"(0,1 – 1,6) mg/m3"},{"name":"Range","range":"(0,001 – 0,032) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Chlorine concentration / content Spectrophotometric method Range Range PB-58/W6-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,1 – 1,6) mg/m3"},{"name":"范围","range":"(0,001 – 0,032) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 氯的浓度/含量 分光光度法 范围 范围 PB-58/W6-17.03.2016","technique_zh":"分光光度法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氯的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20462","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja chloru (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja chloru (z obliczeń)","reference":"PB-58/W6-17.03.2016","norm_bases":["PB-58/W6-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja chloru (z obliczeń) PB-58/W6-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja chloru (z obliczen) PB-58/W6-17.03.2016","categories":["environment"],"row_index":223,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Chlorine emission (calculated) PB-58/W6-17.03.2016","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 氯排放（由计算得出） PB-58/W6-17.03.2016","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"氯排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20463","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia fenolu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fenolu","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia fenolu PB-33/W11-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia fenolu PB-33/W11-01.06.2026","categories":["other"],"row_index":224,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of phenol concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of phenol concentration PB-33/W11-01.06.2026","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 PB-33/W11-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b20464","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,2 – 16) mg/m3"},{"name":"Zakres","range":"(0,002 – 0,4) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość fenolu\nZakres:\nZakres (0,2 – 16) mg/m3\nZakres (0,002 – 0,4) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-31/W7-17.03.2016","norm_bases":["PB-31/W7-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość fenolu\nZakres:\nZakres (0,2 – 16) mg/m3\nZakres (0,002 – 0,4) mg w próbce\nMetoda spektrofotometryczna PB-31/W7-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc fenolu\nZakres:\nZakres (0,2 – 16) mg/m3\nZakres (0,002 – 0,4) mg w probce\nMetoda spektrofotometryczna PB-31/W7-17.03.2016","categories":["other"],"row_index":225,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration / content","parameters_en":[{"name":"Range","range":"(0,2 – 16) mg/m3"},{"name":"Range","range":"(0,002 – 0,4) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Phenol concentration / content Spectrophotometric method Range Range PB-31/W7-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,2 – 16) mg/m3"},{"name":"范围","range":"(0,002 – 0,4) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 苯酚的浓度/含量 分光光度法 范围 范围 PB-31/W7-17.03.2016","technique_zh":"分光光度法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"苯酚的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20465","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja fenolu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja fenolu (z obliczeń)","reference":"PB-31/W7-17.03.2016","norm_bases":["PB-31/W7-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja fenolu (z obliczeń) PB-31/W7-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja fenolu (z obliczen) PB-31/W7-17.03.2016","categories":["environment"],"row_index":226,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Phenol emission (calculated) PB-31/W7-17.03.2016","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 苯酚排放（由计算得出） PB-31/W7-17.03.2016","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"苯酚排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20466","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia/zawartość formaldehydu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia/zawartość formaldehydu","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia/zawartość formaldehydu PB-33/W11-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia/zawartosc formaldehydu PB-33/W11-01.06.2026","categories":["other"],"row_index":227,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration/content of formaldehyde","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for determination of the concentration/content of formaldehyde PB-33/W11-01.06.2026","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 PB-33/W11-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品"},{"_id":"6a83ae76af14b9c0e7b20467","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,04 – 60) mg/m3"},{"name":"Zakres","range":"(0,0004 – 0,66) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,04 – 60) mg/m3\nZakres (0,0004 – 0,66) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-67/W3-17.03.2016","norm_bases":["PB-67/W3-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość formaldehydu\nZakres:\nZakres (0,04 – 60) mg/m3\nZakres (0,0004 – 0,66) mg w próbce\nMetoda spektrofotometryczna PB-67/W3-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc formaldehydu\nZakres:\nZakres (0,04 – 60) mg/m3\nZakres (0,0004 – 0,66) mg w probce\nMetoda spektrofotometryczna PB-67/W3-17.03.2016","categories":["other"],"row_index":228,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration / content","parameters_en":[{"name":"Range","range":"(0,04 – 60) mg/m3"},{"name":"Range","range":"(0,0004 – 0,66) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Formaldehyde concentration / content Spectrophotometric method Range Range PB-67/W3-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,04 – 60) mg/m3"},{"name":"范围","range":"(0,0004 – 0,66) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 甲醛的浓度/含量 分光光度法 范围 范围 PB-67/W3-17.03.2016","technique_zh":"分光光度法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"甲醛的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20468","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja formaldehydu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja formaldehydu (z obliczeń)","reference":"PB-67/W3-17.03.2016","norm_bases":["PB-67/W3-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja formaldehydu (z obliczeń) PB-67/W3-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja formaldehydu (z obliczen) PB-67/W3-17.03.2016","categories":["environment"],"row_index":229,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Formaldehyde emission (calculated) PB-67/W3-17.03.2016","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 甲醛释放量（由计算得出） PB-67/W3-17.03.2016","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"甲醛释放量（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20469","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia ozonu","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia ozonu\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia ozonu\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających PB-33/W11-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia ozonu\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych PB-33/W11-01.06.2026","categories":["other"],"row_index":230,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of ozone concentration","search_en":"Waste gases – waste gas samples collected into absorbing solution Sampling for the determination of ozone concentration Aspiration method using absorbing solutions PB-33/W11-01.06.2026","technique_en":"Aspiration method using absorbing solutions","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 用于测定臭氧浓度的采样 采用吸收液的抽气法 PB-33/W11-01.06.2026","test_object_zh":"废气 — 采集于吸收液的废气样品","technique_zh":"采用吸收液的抽气法","methodology_zh":"用于测定臭氧浓度的采样"},{"_id":"6a83ae76af14b9c0e7b2046a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,02 – 6,67) mg/m3"},{"name":"Zakres","range":"(0,001 – 0,20) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość ozonu\nZakres:\nZakres (0,02 – 6,67) mg/m3\nZakres (0,001 – 0,20) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-104/W3-17.03.2016","norm_bases":["PB-104/W3-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość ozonu\nZakres:\nZakres (0,02 – 6,67) mg/m3\nZakres (0,001 – 0,20) mg w próbce\nMetoda spektrofotometryczna PB-104/W3-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc ozonu\nZakres:\nZakres (0,02 – 6,67) mg/m3\nZakres (0,001 – 0,20) mg w probce\nMetoda spektrofotometryczna PB-104/W3-17.03.2016","categories":["other"],"row_index":231,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of ozone","parameters_en":[{"name":"Range","range":"(0,02 – 6,67) mg/m3"},{"name":"Range","range":"(0,001 – 0,20) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected into absorbing solution Concentration / content of ozone Spectrophotometric method Range Range PB-104/W3-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,02 – 6,67) mg/m3"},{"name":"范围","range":"(0,001 – 0,20) mg w próbce"}],"search_zh":"废气 — 采集于吸收液的废气样品 臭氧的浓度/含量 分光光度法 范围 范围 PB-104/W3-17.03.2016","technique_zh":"分光光度法","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"臭氧的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b2046b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja ozonu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja ozonu (z obliczeń)","reference":"PB-104/W3-17.03.2016","norm_bases":["PB-104/W3-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja ozonu (z obliczeń) PB-104/W3-17.03.2016 Gazy odlotowe – probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja ozonu (z obliczen) PB-104/W3-17.03.2016","categories":["environment"],"row_index":232,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone emission (calculated)","search_en":"Waste gases – waste gas samples collected into absorbing solution Ozone emission (calculated) PB-104/W3-17.03.2016","test_object_en":"Waste gases – waste gas samples collected into absorbing solution","search_zh":"废气 — 采集于吸收液的废气样品 臭氧排放（由计算得出） PB-104/W3-17.03.2016","test_object_zh":"废气 — 采集于吸收液的废气样品","methodology_zh":"臭氧排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b2046c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia NO2, NOx","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia NO2, NOx","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia NO2, NOx PB-33/W11-01.06.2026 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia NO2, NOx PB-33/W11-01.06.2026","categories":["other"],"row_index":233,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of NO2, NOx","search_en":"Waste gases - waste gas samples collected into absorbing solution Sampling for determination of the concentration of NO2, NOx PB-33/W11-01.06.2026","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 PB-33/W11-01.06.2026","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2046d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2)","parameters":[{"name":"Zakres","range":"(0,04 – 100) mg/m3"},{"name":"Zakres","range":"(0,0002 – 0,4) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2)\nZakres:\nZakres (0,04 – 100) mg/m3\nZakres (0,0002 – 0,4) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-59/W5-17.03.2016","norm_bases":["PB-59/W5-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2)\nZakres:\nZakres (0,04 – 100) mg/m3\nZakres (0,0002 – 0,4) mg w próbce\nMetoda spektrofotometryczna PB-59/W5-17.03.2016 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2)\nZakres:\nZakres (0,04 – 100) mg/m3\nZakres (0,0002 – 0,4) mg w probce\nMetoda spektrofotometryczna PB-59/W5-17.03.2016","categories":["other"],"row_index":234,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of NO2 and NOx (sum of NO and NO2 expressed as NO2)","parameters_en":[{"name":"Range","range":"(0,04 – 100) mg/m3"},{"name":"Range","range":"(0,0002 – 0,4) mg w próbce"}],"search_en":"Waste gases - waste gas samples collected into absorbing solution Concentration / content of NO2 and NOx (sum of NO and NO2 expressed as NO2) Spectrophotometric method Range Range PB-59/W5-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,04 – 100) mg/m3"},{"name":"范围","range":"(0,0002 – 0,4) mg w próbce"}],"search_zh":"排放气体 － 采集于吸收液中的排放气体样品 分光光度法 范围 范围 PB-59/W5-17.03.2016","technique_zh":"分光光度法","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2046e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PB-59/W5-17.03.2016","norm_bases":["PB-59/W5-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2) (z obliczeń) PB-59/W5-17.03.2016 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja NO2 i NOx (suma NO i NO2 w przeliczeniu na NO2) (z obliczen) PB-59/W5-17.03.2016","categories":["environment"],"row_index":235,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of NO2 and NOx (sum of NO and NO2 calculated as NO2) (calculated)","search_en":"Waste gases - waste gas samples collected into absorbing solution Emission of NO2 and NOx (sum of NO and NO2 calculated as NO2) (calculated) PB-59/W5-17.03.2016","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 PB-59/W5-17.03.2016","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2046f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia NO","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia NO","reference":"PB-33/W11-01.06.2026","norm_bases":["PB-33/W11-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia NO PB-33/W11-01.06.2026 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia NO PB-33/W11-01.06.2026","categories":["other"],"row_index":236,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of NO concentration","search_en":"Waste gases - waste gas samples collected into absorbing solution Sampling for determination of NO concentration PB-33/W11-01.06.2026","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 PB-33/W11-01.06.2026","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20470","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość NO","parameters":[{"name":"Zakres","range":"( 0,026 – 65,2) mg/m3"},{"name":"Zakres","range":"(0,00013- 0,26) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość NO\nZakres:\nZakres ( 0,026 – 65,2) mg/m3\nZakres (0,00013- 0,26) mg w próbce\nMetoda spektrofotometryczna","reference":"PB-59/W5-17.03.2016","norm_bases":["PB-59/W5-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość NO\nZakres:\nZakres ( 0,026 – 65,2) mg/m3\nZakres (0,00013- 0,26) mg w próbce\nMetoda spektrofotometryczna PB-59/W5-17.03.2016 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc NO\nZakres:\nZakres ( 0,026 – 65,2) mg/m3\nZakres (0,00013- 0,26) mg w probce\nMetoda spektrofotometryczna PB-59/W5-17.03.2016","categories":["other"],"row_index":237,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of NO","parameters_en":[{"name":"Range","range":"( 0,026 – 65,2) mg/m3"},{"name":"Range","range":"(0,00013- 0,26) mg w próbce"}],"search_en":"Waste gases - waste gas samples collected into absorbing solution Concentration / content of NO Spectrophotometric method Range Range PB-59/W5-17.03.2016","technique_en":"Spectrophotometric method","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"( 0,026 – 65,2) mg/m3"},{"name":"范围","range":"(0,00013- 0,26) mg w próbce"}],"search_zh":"排放气体 － 采集于吸收液中的排放气体样品 分光光度法 范围 范围 PB-59/W5-17.03.2016","technique_zh":"分光光度法","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20471","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja NO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO (z obliczeń)","reference":"PB-59/W5-17.03.2016","norm_bases":["PB-59/W5-17.03.2016"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja NO (z obliczeń) PB-59/W5-17.03.2016 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja NO (z obliczen) PB-59/W5-17.03.2016","categories":["environment"],"row_index":238,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO emission (calculated)","search_en":"Waste gases - waste gas samples collected into absorbing solution NO emission (calculated) PB-59/W5-17.03.2016","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 PB-59/W5-17.03.2016","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20472","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":239,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of ammonia concentration","search_en":"Waste gases - waste gas samples collected into absorbing solution Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","methodology_zh":"氨浓度测定采样","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 氨浓度测定采样 PN-EN ISO 21877:2020-03","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20473","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Stężenie / zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,1 – 150) mg/m3"},{"name":"Zakres","range":"(0,000145 – 0,045) mg/ml"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie / zawartość amoniaku\nZakres:\nZakres (0,1 – 150) mg/m3\nZakres (0,000145 – 0,045) mg/ml\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Stężenie / zawartość amoniaku\nZakres:\nZakres (0,1 – 150) mg/m3\nZakres (0,000145 – 0,045) mg/ml\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Stezenie / zawartosc amoniaku\nZakres:\nZakres (0,1 – 150) mg/m3\nZakres (0,000145 – 0,045) mg/ml\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":240,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration / content","parameters_en":[{"name":"Range","range":"(0,1 – 150) mg/m3"},{"name":"Range","range":"(0,000145 – 0,045) mg/ml"}],"search_en":"Waste gases - waste gas samples collected into absorbing solution Ammonia concentration / content Spectrophotometric method Range Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,1 – 150) mg/m3"},{"name":"范围","range":"(0,000145 – 0,045) mg/ml"}],"search_zh":"排放气体 － 采集于吸收液中的排放气体样品 氨的浓度/含量 分光光度法 范围 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品","methodology_zh":"氨的浓度/含量"},{"_id":"6a83ae76af14b9c0e7b20474","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego","methodology":"Emisja amoniaku (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja amoniaku (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego Emisja amoniaku (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego Emisja amoniaku (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":241,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia emission (calculated)","search_en":"Waste gases - waste gas samples collected into absorbing solution Ammonia emission (calculated) PN-EN ISO 21877:2020-03","test_object_en":"Waste gases - waste gas samples collected into absorbing solution","methodology_zh":"氨排放量（计算值）","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 氨排放量（计算值） PN-EN ISO 21877:2020-03","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20475","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Pobieranie próbek do oznaczania stężenia metali Fe, Al,","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali Fe, Al,","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Pobieranie próbek do oznaczania stężenia metali Fe, Al, PN-EN 14385:2025-05 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Pobieranie probek do oznaczania stezenia metali Fe, Al, PN-EN 14385:2025-05","categories":["materials"],"row_index":242,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations Fe, Al,","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Sampling for determination of metal concentrations Fe, Al, PN-EN 14385:2025-05","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 PN-EN 14385:2025-05","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20476","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Emisja Fe, Al (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja Fe, Al (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Emisja Fe, Al (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Emisja Fe, Al (z obliczen) PN-EN 14385:2025-05","categories":["environment"],"row_index":243,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of Fe, Al (calculated)","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Emission of Fe, Al (calculated) PN-EN 14385:2025-05","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 PN-EN 14385:2025-05","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20477","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Pobieranie próbek do oznaczania stężenia metali Ba, Bi, Zn, Sn, Mo, Se, Ag","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali Ba, Bi, Zn, Sn, Mo, Se, Ag","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Pobieranie próbek do oznaczania stężenia metali Ba, Bi, Zn, Sn, Mo, Se, Ag PN-EN 14385:2025-05 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Pobieranie probek do oznaczania stezenia metali Ba, Bi, Zn, Sn, Mo, Se, Ag PN-EN 14385:2025-05","categories":["materials"],"row_index":244,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations Ba, Bi, Zn, Sn, Mo, Se, Ag","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Sampling for determination of metal concentrations Ba, Bi, Zn, Sn, Mo, Se, Ag PN-EN 14385:2025-05","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 PN-EN 14385:2025-05","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20478","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr","methodology":"Emisja Ba, Bi, Zn, Sn, Mo, Se, Ag (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja Ba, Bi, Zn, Sn, Mo, Se, Ag (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe - próbki gazów odlotowych pobranych do roztworu pochłaniającego - próbki gazów odlotowych pobranych na filtr Emisja Ba, Bi, Zn, Sn, Mo, Se, Ag (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe - probki gazow odlotowych pobranych do roztworu pochlaniajacego - probki gazow odlotowych pobranych na filtr Emisja Ba, Bi, Zn, Sn, Mo, Se, Ag (z obliczen) PN-EN 14385:2025-05","categories":["environment"],"row_index":245,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of Ba, Bi, Zn, Sn, Mo, Se, Ag (calculated)","search_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter Emission of Ba, Bi, Zn, Sn, Mo, Se, Ag (calculated) PN-EN 14385:2025-05","test_object_en":"Waste gases - waste gas samples collected into absorbing solution - waste gas samples collected on a filter","search_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品 PN-EN 14385:2025-05","test_object_zh":"排放气体 － 采集于吸收液中的排放气体样品 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b20479","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr","methodology":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego","reference":"PB-97/W5-01.06.2026","norm_bases":["PB-97/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr Pobieranie próbek do oznaczania stężenia kwasu siarkowego PB-97/W5-01.06.2026 Gazy odlotowe – probki gazow odlotowych pobranych na filtr Pobieranie probek do oznaczania stezenia kwasu siarkowego PB-97/W5-01.06.2026","categories":["other"],"row_index":246,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of sulfuric acid concentration","search_en":"Waste gases – waste gas samples collected on a filter Sampling for determination of sulfuric acid concentration PB-97/W5-01.06.2026","test_object_en":"Waste gases – waste gas samples collected on a filter","search_zh":"排放气体 － 采集在滤膜上的排放气体样品 PB-97/W5-01.06.2026","test_object_zh":"排放气体 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2047a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr","methodology":"Stężenie / zawartość kwasu siarkowego","parameters":[{"name":"Zakres","range":"(0,2 – 4,0) mg/m3"},{"name":"Zakres","range":"(0,20 – 1,0) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie / zawartość kwasu siarkowego\nZakres:\nZakres (0,2 – 4,0) mg/m3\nZakres (0,20 – 1,0) mg w próbce\nMetoda turbidymetryczna","reference":"PB-69/W4-18.03.2015","norm_bases":["PB-69/W4-18.03.2015"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr Stężenie / zawartość kwasu siarkowego\nZakres:\nZakres (0,2 – 4,0) mg/m3\nZakres (0,20 – 1,0) mg w próbce\nMetoda turbidymetryczna PB-69/W4-18.03.2015 Gazy odlotowe – probki gazow odlotowych pobranych na filtr Stezenie / zawartosc kwasu siarkowego\nZakres:\nZakres (0,2 – 4,0) mg/m3\nZakres (0,20 – 1,0) mg w probce\nMetoda turbidymetryczna PB-69/W4-18.03.2015","categories":["other"],"row_index":247,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of sulphuric acid","parameters_en":[{"name":"Range","range":"(0,2 – 4,0) mg/m3"},{"name":"Range","range":"(0,20 – 1,0) mg w próbce"}],"search_en":"Waste gases – waste gas samples collected on a filter Concentration / content of sulphuric acid Turbidimetric method Range Range PB-69/W4-18.03.2015","technique_en":"Turbidimetric method","test_object_en":"Waste gases – waste gas samples collected on a filter","parameters_zh":[{"name":"范围","range":"(0,2 – 4,0) mg/m3"},{"name":"范围","range":"(0,20 – 1,0) mg w próbce"}],"search_zh":"排放气体 － 采集在滤膜上的排放气体样品 浊度法 范围 范围 PB-69/W4-18.03.2015","technique_zh":"浊度法","test_object_zh":"排放气体 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2047b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr","methodology":"Emisja kwasu siarkowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja kwasu siarkowego (z obliczeń)","reference":"PB-69/W4-18.03.2015","norm_bases":["PB-69/W4-18.03.2015"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr Emisja kwasu siarkowego (z obliczeń) PB-69/W4-18.03.2015 Gazy odlotowe – probki gazow odlotowych pobranych na filtr Emisja kwasu siarkowego (z obliczen) PB-69/W4-18.03.2015","categories":["environment"],"row_index":248,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfuric acid emission (calculated)","search_en":"Waste gases – waste gas samples collected on a filter Sulfuric acid emission (calculated) PB-69/W4-18.03.2015","test_object_en":"Waste gases – waste gas samples collected on a filter","methodology_zh":"硫酸排放（由计算得出）","search_zh":"排放气体 － 采集在滤膜上的排放气体样品 硫酸排放（由计算得出） PB-69/W4-18.03.2015","test_object_zh":"排放气体 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2047c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr","methodology":"Pobieranie próbek do oznaczania stężenia izocyjanianów: 2,4-TDI, 2,6-TDI, MDI, HDI","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem filtrów","techniques":["Metoda aspiracyjna z zastosowaniem filtrów"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia izocyjanianów: 2,4-TDI, 2,6-TDI, MDI, HDI\nMetoda aspiracyjna z zastosowaniem filtrów","reference":"PB-105/W2-03.08.2015","norm_bases":["PB-105/W2-03.08.2015"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr Pobieranie próbek do oznaczania stężenia izocyjanianów: 2,4-TDI, 2,6-TDI, MDI, HDI\nMetoda aspiracyjna z zastosowaniem filtrów PB-105/W2-03.08.2015 Gazy odlotowe – probki gazow odlotowych pobranych na filtr Pobieranie probek do oznaczania stezenia izocyjanianow: 2,4-TDI, 2,6-TDI, MDI, HDI\nMetoda aspiracyjna z zastosowaniem filtrow PB-105/W2-03.08.2015","categories":["other"],"row_index":249,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of isocyanates: 2,4-TDI, 2,6-TDI, MDI, HDI","search_en":"Waste gases – waste gas samples collected on a filter Sampling for determination of the concentration of isocyanates: 2,4-TDI, 2,6-TDI, MDI, HDI Aspiration method using filters PB-105/W2-03.08.2015","technique_en":"Aspiration method using filters","test_object_en":"Waste gases – waste gas samples collected on a filter","search_zh":"排放气体 － 采集在滤膜上的排放气体样品 滤膜抽气采样法 PB-105/W2-03.08.2015","technique_zh":"滤膜抽气采样法","test_object_zh":"排放气体 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2047d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr","methodology":"Stężenie / zawartość izocyjanianów","parameters":[{"name":"Zakres","range":"2,4-TDI (diizocyjanian tolueno-2,4-"},{"name":"diylu; 2,4-diizocyjanianotoluen)"},{"name":"Zakres","range":"(0,0001 – 0,2) mg/m3"},{"name":"Zakres","range":"(0,10 – 50,0) μg w próbce"},{"name":"2,6-TDI","range":"( diizocyjanian tolueno-2,6-diylu; 2,6-diizocyjanianotoluen)"},{"name":"Zakres","range":"(0,0001 – 0,2) mg/m3"},{"name":"Zakres","range":"(0,10 – 50,0) μg w próbce"},{"name":"MDI (metylenobis (fenyloizocyjanian), 4,4’-metylenobis(fenyloizocyjanian)"},{"name":"Zakres","range":"(0,0001 – 0,2) mg/m3"},{"name":"Zakres","range":"(0,10 – 50,0) μg w próbce"},{"name":"HDI","range":"(diizocyjanian heksano-1,6-diylu; 1,6-heksametylenodiizocyjanian)"},{"name":"Zakres","range":"(0,0001 – 0,2) mg/m3"},{"name":"Zakres","range":"(0,10 – 50,0) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość izocyjanianów\nZakres:\nZakres 2,4-TDI (diizocyjanian tolueno-2,4-\ndiylu; 2,4-diizocyjanianotoluen)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\n2,6-TDI ( diizocyjanian tolueno-2,6-diylu; 2,6-diizocyjanianotoluen)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\nMDI (metylenobis (fenyloizocyjanian), 4,4’-metylenobis(fenyloizocyjanian)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\nHDI (diizocyjanian heksano-1,6-diylu; 1,6-heksametylenodiizocyjanian)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-103/W2-18.03.2015 *","norm_bases":["PB-103/W2-18.03.2015 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr Stężenie / zawartość izocyjanianów\nZakres:\nZakres 2,4-TDI (diizocyjanian tolueno-2,4-\ndiylu; 2,4-diizocyjanianotoluen)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\n2,6-TDI ( diizocyjanian tolueno-2,6-diylu; 2,6-diizocyjanianotoluen)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\nMDI (metylenobis (fenyloizocyjanian), 4,4’-metylenobis(fenyloizocyjanian)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\nHDI (diizocyjanian heksano-1,6-diylu; 1,6-heksametylenodiizocyjanian)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-103/W2-18.03.2015 * Gazy odlotowe – probki gazow odlotowych pobranych na filtr Stezenie / zawartosc izocyjanianow\nZakres:\nZakres 2,4-TDI (diizocyjanian tolueno-2,4-\ndiylu; 2,4-diizocyjanianotoluen)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w probce\n2,6-TDI ( diizocyjanian tolueno-2,6-diylu; 2,6-diizocyjanianotoluen)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w probce\nMDI (metylenobis (fenyloizocyjanian), 4,4’-metylenobis(fenyloizocyjanian)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w probce\nHDI (diizocyjanian heksano-1,6-diylu; 1,6-heksametylenodiizocyjanian)\nZakres (0,0001 – 0,2) mg/m3\nZakres (0,10 – 50,0) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-103/W2-18.03.2015 *","categories":["other"],"row_index":250,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of isocyanates","parameters_en":[{"name":"Range","range":"2,4-TDI (diizocyjanian tolueno-2,4-"},{"name":"diyl; 2,4-diisocyanatotoluene)"},{"name":"Range","range":"(0,0001 – 0,2) mg/m3"},{"name":"Range","range":"(0,10 – 50,0) μg w próbce"},{"name":"2,6-TDI","range":"( diizocyjanian tolueno-2,6-diylu; 2,6-diizocyjanianotoluen)"},{"name":"Range","range":"(0,0001 – 0,2) mg/m3"},{"name":"Range","range":"(0,10 – 50,0) μg w próbce"},{"name":"MDI (methylenebis (phenyl isocyanate), 4,4’-methylenebis(phenyl isocyanate)"},{"name":"Range","range":"(0,0001 – 0,2) mg/m3"},{"name":"Range","range":"(0,10 – 50,0) μg w próbce"},{"name":"HDI","range":"(diizocyjanian heksano-1,6-diylu; 1,6-heksametylenodiizocyjanian)"},{"name":"Range","range":"(0,0001 – 0,2) mg/m3"},{"name":"Range","range":"(0,10 – 50,0) μg w próbce"}],"search_en":"Waste gases – waste gas samples collected on a filter Concentration / content of isocyanates High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range diyl; 2,4-diisocyanatotoluene) Range Range 2,6-TDI Range Range MDI (methylenebis (phenyl isocyanate), 4,4’-methylenebis(phenyl isocyanate) Range Range HDI Range Range PB-103/W2-18.03.2015 *","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Waste gases – waste gas samples collected on a filter","parameters_zh":[{"name":"范围","range":"2,4-TDI (diizocyjanian tolueno-2,4-"},{"name":"diylu; 2,4-diizocyjanianotoluen)"},{"name":"范围","range":"(0,0001 – 0,2) mg/m3"},{"name":"范围","range":"(0,10 – 50,0) μg w próbce"},{"name":"2,6-TDI","range":"( diizocyjanian tolueno-2,6-diylu; 2,6-diizocyjanianotoluen)"},{"name":"范围","range":"(0,0001 – 0,2) mg/m3"},{"name":"范围","range":"(0,10 – 50,0) μg w próbce"},{"name":"MDI (metylenobis (fenyloizocyjanian), 4,4’-metylenobis(fenyloizocyjanian)"},{"name":"范围","range":"(0,0001 – 0,2) mg/m3"},{"name":"范围","range":"(0,10 – 50,0) μg w próbce"},{"name":"HDI","range":"(diizocyjanian heksano-1,6-diylu; 1,6-heksametylenodiizocyjanian)"},{"name":"范围","range":"(0,0001 – 0,2) mg/m3"},{"name":"范围","range":"(0,10 – 50,0) μg w próbce"}],"search_zh":"排放气体 － 采集在滤膜上的排放气体样品 高效液相色谱-荧光检测法（HPLC-FLD） 范围 范围 范围 范围 范围 范围 范围 范围 范围 PB-103/W2-18.03.2015 *","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"排放气体 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2047e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr","methodology":"Emisja izocyjanianów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja izocyjanianów (z obliczeń)","reference":"PB-103/W2-18.03.2015 *","norm_bases":["PB-103/W2-18.03.2015 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr Emisja izocyjanianów (z obliczeń) PB-103/W2-18.03.2015 * Gazy odlotowe – probki gazow odlotowych pobranych na filtr Emisja izocyjanianow (z obliczen) PB-103/W2-18.03.2015 *","categories":["environment"],"row_index":251,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Isocyanate emission (calculated)","search_en":"Waste gases – waste gas samples collected on a filter Isocyanate emission (calculated) PB-103/W2-18.03.2015 *","test_object_en":"Waste gases – waste gas samples collected on a filter","search_zh":"排放气体 － 采集在滤膜上的排放气体样品 PB-103/W2-18.03.2015 *","test_object_zh":"排放气体 － 采集在滤膜上的排放气体样品"},{"_id":"6a83ae76af14b9c0e7b2047f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr, sorbent i do roztworu pochłaniającego","methodology":"Pobieranie próbek do oznaczania stężenia WWA","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia WWA","reference":"ISO 11338-1:2003","norm_bases":["ISO 11338-1:2003"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr, sorbent i do roztworu pochłaniającego Pobieranie próbek do oznaczania stężenia WWA ISO 11338-1:2003 Gazy odlotowe – probki gazow odlotowych pobranych na filtr, sorbent i do roztworu pochlaniajacego Pobieranie probek do oznaczania stezenia WWA ISO 11338-1:2003","categories":["other"],"row_index":252,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the determination of PAH concentration","search_en":"Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution Sampling for the determination of PAH concentration ISO 11338-1:2003","test_object_en":"Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution","methodology_zh":"用于测定多环芳烃浓度的采样","search_zh":"用于测定多环芳烃浓度的采样 ISO 11338-1:2003"},{"_id":"6a83ae76af14b9c0e7b20480","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr, sorbent i do roztworu pochłaniającego","methodology":"Stężenie / zawartość WWA","parameters":[{"name":"naftalenu"},{"name":"acenaftalenu"},{"name":"fenantrenu"},{"name":"fluorantenu"},{"name":"benzo(a)antracenu"},{"name":"benzo(k)fluorantenu"},{"name":"benzo(a)pirenu"},{"name":"dibenzo(a,h)antracenu"},{"name":"fluorenu"},{"name":"antracenu"},{"name":"pirenu"},{"name":"chryzenu"},{"name":"benzo(b)fluorantenu indeno(1,2,3-cd)pirenu"},{"name":"benzo(ghi)perylenu"},{"name":"Zakres","range":"(0,00005 – 1) mg/m3"},{"name":"Zakres","range":"(0,050 – 5,0) μg w próbce"},{"name":"Suma węglowodorów aromatycznych (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie / zawartość WWA\nZakres:\nnaftalenu\nacenaftalenu\nfenantrenu\nfluorantenu\nbenzo(a)antracenu\nbenzo(k)fluorantenu\nbenzo(a)pirenu\ndibenzo(a,h)antracenu\nfluorenu\nantracenu\npirenu\nchryzenu\nbenzo(b)fluorantenu indeno(1,2,3-cd)pirenu\nbenzo(ghi)perylenu\nZakres (0,00005 – 1) mg/m3\nZakres (0,050 – 5,0) μg w próbce\nSuma węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"ISO 11338-2:2003 *","norm_bases":["ISO 11338-2:2003 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr, sorbent i do roztworu pochłaniającego Stężenie / zawartość WWA\nZakres:\nnaftalenu\nacenaftalenu\nfenantrenu\nfluorantenu\nbenzo(a)antracenu\nbenzo(k)fluorantenu\nbenzo(a)pirenu\ndibenzo(a,h)antracenu\nfluorenu\nantracenu\npirenu\nchryzenu\nbenzo(b)fluorantenu indeno(1,2,3-cd)pirenu\nbenzo(ghi)perylenu\nZakres (0,00005 – 1) mg/m3\nZakres (0,050 – 5,0) μg w próbce\nSuma węglowodorów aromatycznych (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) ISO 11338-2:2003 * Gazy odlotowe – probki gazow odlotowych pobranych na filtr, sorbent i do roztworu pochlaniajacego Stezenie / zawartosc WWA\nZakres:\nnaftalenu\nacenaftalenu\nfenantrenu\nfluorantenu\nbenzo(a)antracenu\nbenzo(k)fluorantenu\nbenzo(a)pirenu\ndibenzo(a,h)antracenu\nfluorenu\nantracenu\npirenu\nchryzenu\nbenzo(b)fluorantenu indeno(1,2,3-cd)pirenu\nbenzo(ghi)perylenu\nZakres (0,00005 – 1) mg/m3\nZakres (0,050 – 5,0) μg w probce\nSuma weglowodorow aromatycznych (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) ISO 11338-2:2003 *","categories":["other"],"row_index":253,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration / content of PAH","parameters_en":[{"name":"naphthalene"},{"name":"acenaphthalene"},{"name":"phenanthrene"},{"name":"fluoranthene"},{"name":"benzo(a)anthracene"},{"name":"benzo(k)fluoranthene"},{"name":"benzo(a)pyrene"},{"name":"dibenzo(a,h)anthracene"},{"name":"fluorene"},{"name":"anthracene"},{"name":"pyrene"},{"name":"chrysene"},{"name":"benzo(b)fluoranthene indeno(1,2,3-cd)pyrene"},{"name":"benzo(ghi)perylene"},{"name":"Range","range":"(0,00005 – 1) mg/m3"},{"name":"Range","range":"(0,050 – 5,0) μg w próbce"},{"name":"Sum of aromatic hydrocarbons (calculated)"}],"search_en":"Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution Concentration / content of PAH High-performance liquid chromatography with fluorescence detection (HPLC-FLD) naphthalene acenaphthalene phenanthrene fluoranthene benzo(a)anthracene benzo(k)fluoranthene benzo(a)pyrene dibenzo(a,h)anthracene fluorene anthracene pyrene chrysene benzo(b)fluoranthene indeno(1,2,3-cd)pyrene benzo(ghi)perylene Range Range Sum of aromatic hydrocarbons (calculated) ISO 11338-2:2003 *","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution","parameters_zh":[{"name":"naftalenu"},{"name":"acenaftalenu"},{"name":"fenantrenu"},{"name":"fluorantenu"},{"name":"苯并(a)蒽"},{"name":"苯并(k)荧蒽"},{"name":"苯并(a)芘"},{"name":"二苯并(a,h)蒽"},{"name":"fluorenu"},{"name":"蒽"},{"name":"pirenu"},{"name":"䓛"},{"name":"benzo(b)fluorantenu indeno(1,2,3-cd)pirenu"},{"name":"benzo(ghi)perylenu"},{"name":"范围","range":"(0,00005 – 1) mg/m3"},{"name":"范围","range":"(0,050 – 5,0) μg w próbce"},{"name":"芳香烃总量（由计算得出）"}],"search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） 苯并(a)蒽 苯并(k)荧蒽 苯并(a)芘 二苯并(a,h)蒽 蒽 䓛 范围 范围 芳香烃总量（由计算得出） ISO 11338-2:2003 *","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a83ae76af14b9c0e7b20481","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr, sorbent i do roztworu pochłaniającego","methodology":"Emisja WWA: naftalenu, acenaftalenu, fenantrenu, fluorantenu, benzo(a)antracenu, benzo(k)fluorantenu, benzo(a)pirenu dibenzo(a,h)antracenu, fluorenu, antracenu, pirenu, chryzenu, benzo(b)fluorantenu, indeno(1,2,3-cd)pirenu, benzo(g,h,i)perylenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja WWA: naftalenu, acenaftalenu, fenantrenu, fluorantenu, benzo(a)antracenu, benzo(k)fluorantenu, benzo(a)pirenu dibenzo(a,h)antracenu, fluorenu, antracenu, pirenu, chryzenu, benzo(b)fluorantenu, indeno(1,2,3-cd)pirenu, benzo(g,h,i)perylenu (z obliczeń)","reference":"ISO 11338-2:2003 *","norm_bases":["ISO 11338-2:2003 *"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe – próbki gazów odlotowych pobranych na filtr, sorbent i do roztworu pochłaniającego Emisja WWA: naftalenu, acenaftalenu, fenantrenu, fluorantenu, benzo(a)antracenu, benzo(k)fluorantenu, benzo(a)pirenu dibenzo(a,h)antracenu, fluorenu, antracenu, pirenu, chryzenu, benzo(b)fluorantenu, indeno(1,2,3-cd)pirenu, benzo(g,h,i)perylenu (z obliczeń) ISO 11338-2:2003 * Gazy odlotowe – probki gazow odlotowych pobranych na filtr, sorbent i do roztworu pochlaniajacego Emisja WWA: naftalenu, acenaftalenu, fenantrenu, fluorantenu, benzo(a)antracenu, benzo(k)fluorantenu, benzo(a)pirenu dibenzo(a,h)antracenu, fluorenu, antracenu, pirenu, chryzenu, benzo(b)fluorantenu, indeno(1,2,3-cd)pirenu, benzo(g,h,i)perylenu (z obliczen) ISO 11338-2:2003 *","categories":["environment"],"row_index":254,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of PAHs: naphthalene, acenaphthylene, phenanthrene, fluoranthene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(a)pyrene dibenzo(a,h)anthracene, fluorene, anthracene, pyrene, chrysene, benzo(b)fluoranthene, indeno(1,2,3-cd)pyrene, benzo(g,h,i)perylene (calculated)","search_en":"Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution Emission of PAHs: naphthalene, acenaphthylene, phenanthrene, fluoranthene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(a)pyrene dibenzo(a,h)anthracene, fluorene, anthracene, pyrene, chrysene, benzo(b)fluoranthene, indeno(1,2,3-cd)pyrene, benzo(g,h,i)perylene (calculated) ISO 11338-2:2003 *","test_object_en":"Waste gases – waste gas samples collected on a filter, sorbent and into an absorbing solution"},{"_id":"6a83ae76af14b9c0e7b20482","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(1,0 – 100000) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (1,0 – 100000) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","norm_bases":["PN-EN 13284-1:2018-02","PN-Z-04030-7:1994","PN-87/M-34129 Metoda A"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia odpylające gazy odlotowe Stężenie pyłu\nZakres (1,0 – 100000) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A Urzadzenia odpylajace gazy odlotowe Stezenie pylu\nZakres (1,0 – 100000) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","categories":["other"],"row_index":255,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100000) mg/m3"}],"search_en":"Waste gas dedusting equipment Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","technique_en":"Gravimetric method","test_object_en":"Waste gas dedusting equipment","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100000) mg/m3"}],"search_zh":"废气除尘设备 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","technique_zh":"重量法","test_object_zh":"废气除尘设备"},{"_id":"6a83ae76af14b9c0e7b20483","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","methodology":"Skuteczność odpylania (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność odpylania (z obliczeń)","reference":"PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","norm_bases":["PN-EN 13284-1:2018-02","PN-Z-04030-7:1994","PN-87/M-34129 Metoda A"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania (z obliczeń) PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania (z obliczen) PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","categories":["other"],"row_index":256,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust removal efficiency (calculated)","search_en":"Waste gas dedusting equipment Dust removal efficiency (calculated) PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","test_object_en":"Waste gas dedusting equipment","search_zh":"废气除尘设备 除尘效率（由计算得出） PN-EN 13284-1:2018-02 | PN-Z-04030-7:1994 | PN-87/M-34129 Metoda A","test_object_zh":"废气除尘设备","methodology_zh":"除尘效率（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20484","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Stężenie dwutlenku siarki SO2","parameters":[{"name":"Zakres","range":"(1,0 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie dwutlenku siarki SO2\nZakres (1,0 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","norm_bases":["PN-EN 14791:2017-4","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Stężenie dwutlenku siarki SO2\nZakres (1,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-4 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Stezenie dwutlenku siarki SO2\nZakres (1,0 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","categories":["other"],"row_index":257,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide SO2 concentration","parameters_en":[{"name":"Range","range":"(1,0 – 2000) mg/m3"}],"search_en":"Waste gas cleaning installations Sulfur dioxide SO2 concentration Thoron method Range PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","technique_en":"Thoron method","test_object_en":"Waste gas cleaning installations","parameters_zh":[{"name":"范围","range":"(1,0 – 2000) mg/m3"}],"search_zh":"废气净化装置 二氧化硫 SO2 浓度 钍射气法 范围 PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","technique_zh":"钍射气法","test_object_zh":"废气净化装置","methodology_zh":"二氧化硫 SO2 浓度"},{"_id":"6a83ae76af14b9c0e7b20485","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Skuteczność redukcji SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność redukcji SO2 (z obliczeń)","reference":"PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","norm_bases":["PN-EN 14791:2017-4","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Skuteczność redukcji SO2 (z obliczeń) PN-EN 14791:2017-4 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Skutecznosc redukcji SO2 (z obliczen) PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","categories":["other"],"row_index":258,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 reduction efficiency (calculated)","search_en":"Waste gas cleaning installations SO2 reduction efficiency (calculated) PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","test_object_en":"Waste gas cleaning installations","search_zh":"废气净化装置 PN-EN 14791:2017-4 | PB-35/W5-01.06.2026","test_object_zh":"废气净化装置"},{"_id":"6a83ae76af14b9c0e7b20486","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Stężenie dwutlenku siarki SO2","parameters":[{"name":"Zakres","range":"(20 – 2860) mg/m3"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie dwutlenku siarki SO2\nZakres (20 – 2860) mg/m3\nMetoda NDIR","reference":"PN-ISO 10396:2001 | PB-35/W5-01.06.2026","norm_bases":["PN-ISO 10396:2001","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Stężenie dwutlenku siarki SO2\nZakres (20 – 2860) mg/m3\nMetoda NDIR PN-ISO 10396:2001 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Stezenie dwutlenku siarki SO2\nZakres (20 – 2860) mg/m3\nMetoda NDIR PN-ISO 10396:2001 | PB-35/W5-01.06.2026","categories":["other"],"row_index":259,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide SO2 concentration","parameters_en":[{"name":"Range","range":"(20 – 2860) mg/m3"}],"search_en":"Waste gas cleaning installations Sulfur dioxide SO2 concentration NDIR method Range PN-ISO 10396:2001 | PB-35/W5-01.06.2026","technique_en":"NDIR method","test_object_en":"Waste gas cleaning installations","parameters_zh":[{"name":"范围","range":"(20 – 2860) mg/m3"}],"search_zh":"废气净化装置 二氧化硫 SO2 浓度 非分散红外法（NDIR） 范围 PN-ISO 10396:2001 | PB-35/W5-01.06.2026","technique_zh":"非分散红外法（NDIR）","test_object_zh":"废气净化装置","methodology_zh":"二氧化硫 SO2 浓度"},{"_id":"6a83ae76af14b9c0e7b20487","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Skuteczność redukcji SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność redukcji SO2 (z obliczeń)","reference":"PN-ISO 10396:2001 | PB-35/W5-01.06.2026","norm_bases":["PN-ISO 10396:2001","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Skuteczność redukcji SO2 (z obliczeń) PN-ISO 10396:2001 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Skutecznosc redukcji SO2 (z obliczen) PN-ISO 10396:2001 | PB-35/W5-01.06.2026","categories":["other"],"row_index":260,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 reduction efficiency (calculated)","search_en":"Waste gas cleaning installations SO2 reduction efficiency (calculated) PN-ISO 10396:2001 | PB-35/W5-01.06.2026","test_object_en":"Waste gas cleaning installations","search_zh":"废气净化装置 PN-ISO 10396:2001 | PB-35/W5-01.06.2026","test_object_zh":"废气净化装置"},{"_id":"6a83ae76af14b9c0e7b20488","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Stężenie tlenku azotu, tlenków azotu","parameters":[{"name":"NO","range":"(2 – 1300) mg/m3"},{"name":"NOx","range":"(3 – 2000) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2 – 1300) mg/m3\nNOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Stężenie tlenku azotu, tlenków azotu\nZakres:\nNO (2 – 1300) mg/m3\nNOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Stezenie tlenku azotu, tlenkow azotu\nZakres:\nNO (2 – 1300) mg/m3\nNOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","categories":["other"],"row_index":261,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides","parameters_en":[{"name":"NO","range":"(2 – 1300) mg/m3"},{"name":"NOx","range":"(3 – 2000) mg/m3"}],"search_en":"Waste gas cleaning installations Concentration of nitrogen monoxide, nitrogen oxides Chemiluminescence method NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","technique_en":"Chemiluminescence method","test_object_en":"Waste gas cleaning installations","parameters_zh":[{"name":"NO","range":"(2 – 1300) mg/m3"},{"name":"NOx","range":"(3 – 2000) mg/m3"}],"search_zh":"废气净化装置 一氧化氮、氮氧化物浓度 化学发光法 NO NOx PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","technique_zh":"化学发光法","methodology_zh":"一氧化氮、氮氧化物浓度","test_object_zh":"废气净化装置"},{"_id":"6a83ae76af14b9c0e7b20489","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Skuteczność redukcji NO, NOx (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność redukcji NO, NOx (z obliczeń)","reference":"PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","norm_bases":["PN-ISO 10396:2001","PN-EN 14792:2017-04","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Skuteczność redukcji NO, NOx (z obliczeń) PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Skutecznosc redukcji NO, NOx (z obliczen) PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","categories":["other"],"row_index":262,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx reduction efficiency (calculated)","search_en":"Waste gas cleaning installations NO, NOx reduction efficiency (calculated) PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","test_object_en":"Waste gas cleaning installations","search_zh":"废气净化装置 PN-ISO 10396:2001 | PN-EN 14792:2017-04 | PB-35/W5-01.06.2026","test_object_zh":"废气净化装置"},{"_id":"6a83ae76af14b9c0e7b2048a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","norm_bases":["PN-EN 12619:2013-05","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","categories":["other"],"row_index":263,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(2 – 1000) mg/m3"}],"search_en":"Waste gas cleaning installations Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Waste gas cleaning installations","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/m3"}],"search_zh":"废气净化装置 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）","test_object_zh":"废气净化装置"},{"_id":"6a83ae76af14b9c0e7b2048b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Skuteczność redukcji substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność redukcji substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","norm_bases":["PN-EN 12619:2013-05","PB-35/W5-01.06.2026"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Skuteczność redukcji substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) PN-EN 12619:2013-05 | PB-35/W5-01.06.2026 Instalacje oczyszczania gazow odlotowych Skutecznosc redukcji substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen) PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","categories":["other"],"row_index":264,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Reduction efficiency of organic substances in the form of gases and vapours expressed as total gaseous organic carbon (calculated)","search_en":"Waste gas cleaning installations Reduction efficiency of organic substances in the form of gases and vapours expressed as total gaseous organic carbon (calculated) PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","test_object_en":"Waste gas cleaning installations","search_zh":"废气净化装置 PN-EN 12619:2013-05 | PB-35/W5-01.06.2026","test_object_zh":"废气净化装置"},{"_id":"6a83ae76af14b9c0e7b2048c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Stężenie WWA","parameters":[{"name":"Zakres","range":"(0,00005 – 1) mg/m3"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie WWA\nZakres (0,00005 – 1) mg/m3\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","norm_bases":["ISO 11338-1:2003 *","ISO 11338-2:2003 *","PB-35/W5-01.06.2026*"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Stężenie WWA\nZakres (0,00005 – 1) mg/m3\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026* Instalacje oczyszczania gazow odlotowych Stezenie WWA\nZakres (0,00005 – 1) mg/m3\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","categories":["other"],"row_index":265,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PAH concentration","parameters_en":[{"name":"Range","range":"(0,00005 – 1) mg/m3"}],"search_en":"Waste gas cleaning installations PAH concentration High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Waste gas cleaning installations","parameters_zh":[{"name":"范围","range":"(0,00005 – 1) mg/m3"}],"search_zh":"废气净化装置 多环芳烃浓度 高效液相色谱-荧光检测法（HPLC-FLD） 范围 ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"废气净化装置","methodology_zh":"多环芳烃浓度"},{"_id":"6a83ae76af14b9c0e7b2048d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Instalacje oczyszczania gazów odlotowych","methodology":"Skuteczność redukcji WWA (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczność redukcji WWA (z obliczeń)","reference":"ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","norm_bases":["ISO 11338-1:2003 *","ISO 11338-2:2003 *","PB-35/W5-01.06.2026*"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Instalacje oczyszczania gazów odlotowych Skuteczność redukcji WWA (z obliczeń) ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026* Instalacje oczyszczania gazow odlotowych Skutecznosc redukcji WWA (z obliczen) ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","categories":["other"],"row_index":266,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PAH reduction efficiency (calculated)","search_en":"Waste gas cleaning installations PAH reduction efficiency (calculated) ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","test_object_en":"Waste gas cleaning installations","search_zh":"废气净化装置 ISO 11338-1:2003 * | ISO 11338-2:2003 * | PB-35/W5-01.06.2026*","test_object_zh":"废气净化装置"},{"_id":"6a83ae76af14b9c0e7b2048e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: Hg, NH3, N2O","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalibracja AMS (QAL2) w zakresie: Hg, NH3, N2O","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: Hg, NH3, N2O PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: Hg, NH3, N2O PN-EN 14181:2015-02","categories":["metrology"],"row_index":267,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"AMS calibration (QAL2) for: Hg, NH3, N2O","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for: Hg, NH3, N2O PN-EN 14181:2015-02","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83ae76af14b9c0e7b2048f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie: Hg, NH3, N2O","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Roczne badanie kontrolne (AST) w zakresie: Hg, NH3, N2O","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: Hg, NH3, N2O PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: Hg, NH3, N2O PN-EN 14181:2015-02","categories":["other"],"row_index":268,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Annual surveillance test (AST) for: Hg, NH3, N2O","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for: Hg, NH3, N2O PN-EN 14181:2015-02","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83ae76af14b9c0e7b20490","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,025 – 104) μg/m3"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generacją zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generacją zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,025 – 104) μg/m3\nMetoda absorpcyjnej spektrometrii atomowej z generacją zimnych par (CVAAS)","reference":"PN-EN 13211:2006","norm_bases":["PN-EN 13211:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie rtęci\nZakres (0,025 – 104) μg/m3\nMetoda absorpcyjnej spektrometrii atomowej z generacją zimnych par (CVAAS) PN-EN 13211:2006 Automatyczne Systemy, Monitoringu (AMS) Stezenie rteci\nZakres (0,025 – 104) μg/m3\nMetoda absorpcyjnej spektrometrii atomowej z generacja zimnych par (CVAAS) PN-EN 13211:2006","categories":["other"],"row_index":269,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,025 – 104) μg/m3"}],"search_en":"Automated Measuring Systems (AMS) Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN 13211:2006","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Automated Measuring Systems (AMS)","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 104) μg/m3"}],"search_zh":"自动测量系统（AMS） 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN 13211:2006","test_object_zh":"自动测量系统（AMS）","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a83ae76af14b9c0e7b20491","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(0,1 – 150) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (0,1 – 150) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie amoniaku\nZakres (0,1 – 150) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Automatyczne Systemy, Monitoringu (AMS) Stezenie amoniaku\nZakres (0,1 – 150) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":270,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(0,1 – 150) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Ammonia concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,1 – 150) mg/m3"}],"search_zh":"自动测量系统（AMS） 氨浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氨浓度"},{"_id":"6a83ae76af14b9c0e7b20492","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie N2O","parameters":[{"name":"Zakres","range":"(4 – 700) mg/m3"}],"technique":"Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","techniques":["Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)"],"computed":[],"activity":"Stężenie N2O\nZakres (4 – 700) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie N2O\nZakres (4 – 700) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010 Automatyczne Systemy, Monitoringu (AMS) Stezenie N2O\nZakres (4 – 700) mg/m3\nMetoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN ISO 21258:2010","categories":["other"],"row_index":271,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"N2O concentration","parameters_en":[{"name":"Range","range":"(4 – 700) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) N2O concentration Non-dispersive infrared spectrometry (NDIR) Range PN-EN ISO 21258:2010","technique_en":"Non-dispersive infrared spectrometry (NDIR)","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(4 – 700) mg/m3"}],"search_zh":"自动测量系统（AMS） N2O 浓度 非分散红外光谱法（NDIR） 范围 PN-EN ISO 21258:2010","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外光谱法（NDIR）","methodology_zh":"N2O 浓度"},{"_id":"6a83ae76af14b9c0e7b20493","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Emisja N2O (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja N2O (z obliczeń)","reference":"PN-EN ISO 21258:2010","norm_bases":["PN-EN ISO 21258:2010"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Emisja N2O (z obliczeń) PN-EN ISO 21258:2010 Automatyczne Systemy, Monitoringu (AMS) Emisja N2O (z obliczen) PN-EN ISO 21258:2010","categories":["environment"],"row_index":272,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"N2O emission (calculated)","search_en":"Automated Measuring Systems (AMS) N2O emission (calculated) PN-EN ISO 21258:2010","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） N2O 排放（由计算得出） PN-EN ISO 21258:2010","test_object_zh":"自动测量系统（AMS）","methodology_zh":"N2O 排放（由计算得出）"},{"_id":"6a83ae76af14b9c0e7b20494","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pyłu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pylu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 PN-EN 14181:2015-02","categories":["metrology"],"row_index":273,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"AMS calibration (QAL2) for: dust, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2","search_en":"Automated Measuring Systems (AMS) AMS calibration (QAL2) for: dust, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 PN-EN 14181:2015-02","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83ae76af14b9c0e7b20495","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie: pyłu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Roczne badanie kontrolne (AST) w zakresie: pyłu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2","reference":"PN-EN 14181:2015-02","norm_bases":["PN-EN 14181:2015-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pyłu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 PN-EN 14181:2015-02 Automatyczne Systemy, Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pylu, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 PN-EN 14181:2015-02","categories":["other"],"row_index":274,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Annual surveillance test (AST) for: dust, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, SO2, CO2, HCl, HF, TVOC, H2O, CO, NO, NO2, NOx, O2 PN-EN 14181:2015-02","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） PN-EN 14181:2015-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83ae76af14b9c0e7b20496","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(1 – 100000) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (1 – 100000) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (1 – 100000) mg/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (1 – 100000) mg/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":275,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(1 – 100000) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Automated Measuring Systems (AMS)","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(1 – 100000) mg/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83ae76af14b9c0e7b20497","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,5 – 50) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pyłu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Automatyczne Systemy, Monitoringu (AMS) Stezenie pylu\nZakres (0,5 – 50) mg/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":276,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,5 – 50) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Dust concentration Gravimetric method Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Automated Measuring Systems (AMS)","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 50) mg/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83ae76af14b9c0e7b20498","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(1 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO2\nZakres (1 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-4","norm_bases":["PN-EN 14791:2017-4"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie SO2\nZakres (1 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-4 Automatyczne Systemy, Monitoringu (AMS) Stezenie SO2\nZakres (1 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-4","categories":["other"],"row_index":277,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(1 – 2000) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) SO2 concentration Thoron method Range PN-EN 14791:2017-4","technique_en":"Thoron method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(1 – 2000) mg/m3"}],"search_zh":"自动测量系统（AMS） SO2 浓度 钍射气法 范围 PN-EN 14791:2017-4","test_object_zh":"自动测量系统（AMS）","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a83ae76af14b9c0e7b20499","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(0,03 – 18) %"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie CO2\nZakres (0,03 – 18) %\nMetoda NDIR","reference":"PN-ISO 10396:2001 | ISO 12039:2019","norm_bases":["PN-ISO 10396:2001","ISO 12039:2019"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO2\nZakres (0,03 – 18) %\nMetoda NDIR PN-ISO 10396:2001 | ISO 12039:2019 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO2\nZakres (0,03 – 18) %\nMetoda NDIR PN-ISO 10396:2001 | ISO 12039:2019","categories":["other"],"row_index":278,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(0,03 – 18) %"}],"search_en":"Automated Measuring Systems (AMS) CO2 concentration NDIR method Range PN-ISO 10396:2001 | ISO 12039:2019","technique_en":"NDIR method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,03 – 18) %"}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外法（NDIR） 范围 PN-ISO 10396:2001 | ISO 12039:2019","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO2 浓度","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a83ae76af14b9c0e7b2049a","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie O2","parameters":[{"name":"Zakres","range":"(3,0 – 21) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie O2\nZakres (3,0 – 21) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie O2\nZakres (3,0 – 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie O2\nZakres (3,0 – 21) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":279,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"O2 concentration","parameters_en":[{"name":"Range","range":"(3,0 – 21) %"}],"search_en":"Automated Measuring Systems (AMS) O2 concentration Paramagnetic method Range PN-EN 14789:2017-04","technique_en":"Paramagnetic method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(3,0 – 21) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法 范围 PN-EN 14789:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a83ae76af14b9c0e7b2049b","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie NO, NOx, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3","parameters":[],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie NO, NOx, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie NO, NOx, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie NO, NOx, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04","categories":["other"],"row_index":280,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx concentration, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3","search_en":"Automated Measuring Systems (AMS) NO, NOx concentration, NO (2 – 1300) mg/m3, NOx (3 – 2000) mg/m3 Chemiluminescence method PN-EN 14792:2017-04","technique_en":"Chemiluminescence method","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） 化学发光法 PN-EN 14792:2017-04","test_object_zh":"自动测量系统（AMS）","technique_zh":"化学发光法"},{"_id":"6a83ae76af14b9c0e7b2049c","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie ditlenku azotu NO2","parameters":[{"name":"Zakres","range":"(2 – 200) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie ditlenku azotu NO2\nZakres (2 – 200) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04 IR-394/W1-17.01.2020","norm_bases":["PN-EN 14792:2017-04 IR-394/W1-17.01.2020"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie ditlenku azotu NO2\nZakres (2 – 200) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 IR-394/W1-17.01.2020 Automatyczne Systemy, Monitoringu (AMS) Stezenie ditlenku azotu NO2\nZakres (2 – 200) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 IR-394/W1-17.01.2020","categories":["other"],"row_index":281,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen dioxide NO2 concentration","parameters_en":[{"name":"Range","range":"(2 – 200) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Nitrogen dioxide NO2 concentration Chemiluminescence method Range PN-EN 14792:2017-04 IR-394/W1-17.01.2020","technique_en":"Chemiluminescence method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(2 – 200) mg/m3"}],"search_zh":"自动测量系统（AMS） 化学发光法 范围 PN-EN 14792:2017-04 IR-394/W1-17.01.2020","test_object_zh":"自动测量系统（AMS）","technique_zh":"化学发光法"},{"_id":"6a83ae76af14b9c0e7b2049d","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Emisja NO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO2 (z obliczeń)","reference":"PN-EN 14792:2017-04 IR-394/W1-17.01.2020","norm_bases":["PN-EN 14792:2017-04 IR-394/W1-17.01.2020"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Emisja NO2 (z obliczeń) PN-EN 14792:2017-04 IR-394/W1-17.01.2020 Automatyczne Systemy, Monitoringu (AMS) Emisja NO2 (z obliczen) PN-EN 14792:2017-04 IR-394/W1-17.01.2020","categories":["environment"],"row_index":282,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO2 emission (calculated)","search_en":"Automated Measuring Systems (AMS) NO2 emission (calculated) PN-EN 14792:2017-04 IR-394/W1-17.01.2020","test_object_en":"Automated Measuring Systems (AMS)","search_zh":"自动测量系统（AMS） PN-EN 14792:2017-04 IR-394/W1-17.01.2020","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83ae76af14b9c0e7b2049e","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(1,25 – 1500) mg/m3"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie CO\nZakres (1,25 – 1500) mg/m3\nMetoda NDIR","reference":"PN-ISO 10396:2001 | PN-EN 15058:2017-04","norm_bases":["PN-ISO 10396:2001","PN-EN 15058:2017-04"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie CO\nZakres (1,25 – 1500) mg/m3\nMetoda NDIR PN-ISO 10396:2001 | PN-EN 15058:2017-04 Automatyczne Systemy, Monitoringu (AMS) Stezenie CO\nZakres (1,25 – 1500) mg/m3\nMetoda NDIR PN-ISO 10396:2001 | PN-EN 15058:2017-04","categories":["other"],"row_index":283,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(1,25 – 1500) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) CO concentration NDIR method Range PN-ISO 10396:2001 | PN-EN 15058:2017-04","technique_en":"NDIR method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(1,25 – 1500) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 非分散红外法（NDIR） 范围 PN-ISO 10396:2001 | PN-EN 15058:2017-04","test_object_zh":"自动测量系统（AMS）","methodology_zh":"CO 浓度","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a83ae76af14b9c0e7b2049f","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie chlorowodoru","parameters":[{"name":"Zakres","range":"(0,2 – 750) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorowodoru\nZakres (0,2 – 750) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie chlorowodoru\nZakres (0,2 – 750) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Automatyczne Systemy, Monitoringu (AMS) Stezenie chlorowodoru\nZakres (0,2 – 750) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":284,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration","parameters_en":[{"name":"Range","range":"(0,2 – 750) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Hydrogen chloride concentration Spectrophotometric method Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,2 – 750) mg/m3"}],"search_zh":"自动测量系统（AMS） 氯化氢浓度 分光光度法 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氯化氢浓度"},{"_id":"6a83ae76af14b9c0e7b204a0","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie fluorowodoru","parameters":[{"name":"Zakres","range":"(0,05 – 200) mg/m3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorowodoru\nZakres (0,05 – 200) mg/m3\nMetoda potencjometryczna","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie fluorowodoru\nZakres (0,05 – 200) mg/m3\nMetoda potencjometryczna ISO 15713:2006 Automatyczne Systemy, Monitoringu (AMS) Stezenie fluorowodoru\nZakres (0,05 – 200) mg/m3\nMetoda potencjometryczna ISO 15713:2006","categories":["other"],"row_index":285,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride concentration","parameters_en":[{"name":"Range","range":"(0,05 – 200) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Hydrogen fluoride concentration Potentiometric method Range ISO 15713:2006","technique_en":"Potentiometric method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,05 – 200) mg/m3"}],"search_zh":"自动测量系统（AMS） 氟化氢浓度 电位法 范围 ISO 15713:2006","technique_zh":"电位法","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氟化氢浓度"},{"_id":"6a83ae76af14b9c0e7b204a1","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/m3"}],"technique":"Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","techniques":["Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)"],"computed":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Automatyczne Systemy, Monitoringu (AMS) Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny\nZakres (2 – 1000) mg/m3\nMetoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":286,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon","parameters_en":[{"name":"Range","range":"(2 – 1000) mg/m3"}],"search_en":"Automated Measuring Systems (AMS) Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Continuous flame ionization detection method (FID) Range PN-EN 12619:2013-05","technique_en":"Continuous flame ionization detection method (FID)","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/m3"}],"search_zh":"自动测量系统（AMS） 以总气态有机碳表示的气态与蒸气态有机物浓度 连续火焰离子化检测法（FID） 范围 PN-EN 12619:2013-05","test_object_zh":"自动测量系统（AMS）","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物浓度","technique_zh":"连续火焰离子化检测法（FID）"},{"_id":"6a83ae76af14b9c0e7b204a2","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Automatyczne Systemy, Monitoringu (AMS)","methodology":"Stężenie pary wodnej (H2O)","parameters":[{"name":"Zakres","range":"(4 – 40) % obj."},{"name":"Zawartość pary wodnej"},{"name":"zakres","range":"(29 – 250) g/m3"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie pary wodnej (H2O)\nZakres:\nZakres (4 – 40) % obj.\nZawartość pary wodnej\nzakres (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-4","norm_bases":["PN-EN 14790:2017-4"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne Systemy, Monitoringu (AMS) Stężenie pary wodnej (H2O)\nZakres:\nZakres (4 – 40) % obj.\nZawartość pary wodnej\nzakres (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-4 Automatyczne Systemy, Monitoringu (AMS) Stezenie pary wodnej (H2O)\nZakres:\nZakres (4 – 40) % obj.\nZawartosc pary wodnej\nzakres (29 – 250) g/m3\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-4","categories":["other"],"row_index":287,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water vapour concentration (H2O)","parameters_en":[{"name":"Range","range":"(4 – 40) % obj."},{"name":"Water vapour content"},{"name":"range","range":"(29 – 250) g/m3"}],"search_en":"Automated Measuring Systems (AMS) Water vapour concentration (H2O) Condensation-adsorption method Range Water vapour content range PN-EN 14790:2017-4","technique_en":"Condensation-adsorption method","test_object_en":"Automated Measuring Systems (AMS)","parameters_zh":[{"name":"范围","range":"(4 – 40) % obj."},{"name":"水蒸气含量"},{"name":"范围","range":"(29 – 250) g/m3"}],"search_zh":"自动测量系统（AMS） 水蒸气浓度（H2O） 冷凝-吸附法 范围 水蒸气含量 范围 PN-EN 14790:2017-4","test_object_zh":"自动测量系统（AMS）","methodology_zh":"水蒸气浓度（H2O）","technique_zh":"冷凝-吸附法"},{"_id":"6a83ae76af14b9c0e7b204a3","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Środowisko ogólne powietrze – imisja","methodology":"Pobieranie próbek pyłu Opad pyłu","parameters":[{"name":"Zakres","range":"(1 – 1110) g/m2"}],"technique":"Metoda opadowa (osiadające cząstki stałe)","techniques":["Metoda opadowa (osiadające cząstki stałe)"],"computed":[],"activity":"Pobieranie próbek pyłu Opad pyłu\nZakres (1 – 1110) g/m2\nMetoda opadowa (osiadające cząstki stałe)","reference":"ASTM D 1739-98(2017) | PB-64/W2-22.06.2012","norm_bases":["ASTM D 1739-98(2017)","PB-64/W2-22.06.2012"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne powietrze – imisja Pobieranie próbek pyłu Opad pyłu\nZakres (1 – 1110) g/m2\nMetoda opadowa (osiadające cząstki stałe) ASTM D 1739-98(2017) | PB-64/W2-22.06.2012 Srodowisko ogolne powietrze – imisja Pobieranie probek pylu Opad pylu\nZakres (1 – 1110) g/m2\nMetoda opadowa (osiadajace czastki stale) ASTM D 1739-98(2017) | PB-64/W2-22.06.2012","categories":["environment"],"row_index":288,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1 – 1110) g/m2"}],"search_en":"General environment air – immission Deposition method (settling particulate matter) Range ASTM D 1739-98(2017) | PB-64/W2-22.06.2012","technique_en":"Deposition method (settling particulate matter)","test_object_en":"General environment air – immission","parameters_zh":[{"name":"范围","range":"(1 – 1110) g/m2"}],"search_zh":"范围 ASTM D 1739-98(2017) | PB-64/W2-22.06.2012"},{"_id":"6a83ae76af14b9c0e7b204a4","lab_id":"69ad52a3de79e566650fb3be","country":"PL","accr_number":"AB 746","accr_body":"PCA","test_object":"Próbki pyłu","methodology":"Stężenie frakcji pyłu (składu ziarnowego) w tym PM2,5 oraz PM10","parameters":[{"name":"Zakres","range":"(0,01 – 2100) um"}],"technique":"Metoda dyfrakcji laserowej z dyspersją w cieczy","techniques":["Metoda dyfrakcji laserowej z dyspersją w cieczy"],"computed":[],"activity":"Stężenie frakcji pyłu (składu ziarnowego) w tym PM2,5 oraz PM10\nZakres (0,01 – 2100) um\nMetoda dyfrakcji laserowej z dyspersją w cieczy","reference":"ISO 13320:2020 | ISO 14488:2007","norm_bases":["ISO 13320:2020","ISO 14488:2007"],"lab_section":"Dział Pomiarowo-Analityczny","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Próbki pyłu Stężenie frakcji pyłu (składu ziarnowego) w tym PM2,5 oraz PM10\nZakres (0,01 – 2100) um\nMetoda dyfrakcji laserowej z dyspersją w cieczy ISO 13320:2020 | ISO 14488:2007 Probki pylu Stezenie frakcji pylu (skladu ziarnowego) w tym PM2,5 oraz PM10\nZakres (0,01 – 2100) um\nMetoda dyfrakcji laserowej z dyspersja w cieczy ISO 13320:2020 | ISO 14488:2007","categories":["other"],"row_index":289,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of dust fractions (particle size distribution) including PM2,5 and PM10","parameters_en":[{"name":"Range","range":"(0,01 – 2100) um"}],"search_en":"Dust samples Concentration of dust fractions (particle size distribution) including PM2,5 and PM10 Laser diffraction method with liquid dispersion Range ISO 13320:2020 | ISO 14488:2007","technique_en":"Laser diffraction method with liquid dispersion","test_object_en":"Dust samples","parameters_zh":[{"name":"范围","range":"(0,01 – 2100) um"}],"search_zh":"粉尘样品 液相分散激光衍射法 范围 ISO 13320:2020 | ISO 14488:2007","technique_zh":"液相分散激光衍射法","test_object_zh":"粉尘样品"}],"has_pdf":true}