{"lab":{"_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","address":"Zawada 26, 28-230 Połaniec","categories":["petro","water","materials","construction","environment"],"city":"Połaniec","imported_at":"2026-03-08T10:42:43.265Z","methods_count":55,"name":"ELPOLAB Sp. z o. o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_743.pdf"],"scope_summary":"","search_text":"elpolab sp. z o. o. zawada 26, 28-230 połaniec petro other materials environment construction food pharma water electronics","status":"active","updated_at":"2026-03-08T14:51:37.974Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T00:57:50.889Z","email_confidence":"high","email_mx":true,"email_source":"https://www.elpolab.pl/kontakt/","fields_of_testing":[{"codes":"C/10/P; C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek paliw stałych, wody, ścieków","en":"Chemical tests and sampling of solid fuels, water, sewage"},{"codes":"C/5; C/10; C/32","pl":"Badania chemiczne materiałów budowlanych, paliw stałych, odpadów","en":"Chemical tests and sampling of building materials, solid fuels, waste"},{"codes":"N/10/P; N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw stałych, wody, ścieków","en":"Tests of physical properties and sampling of solid fuels, water, sewage"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"},{"codes":"O/5; O/32","pl":"Badania promieniowania materiałów budowlanych, odpadów","en":"Tests of radiation of building materials, waste"},{"codes":"P/29","pl":"Pobieranie próbek wody do spożycia przez ludzi","en":"Sampling of drinking water"}],"issue":{"no":"26","date":"09.07.2026"},"parse_date":"2026-08-18T00:57:50.889Z","parse_source":"agent-claude-code","map_coord":[50.432907,21.281047],"map_geo":"nominatim-city","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/272999ee4cc559b8a8b6d253895dc535/AB%20743.pdf","has_en":true,"category_counts":{"petro":36,"water":12,"materials":8,"construction":7,"environment":7},"category_scores":{"petro":18.51,"water":2.06,"materials":0.91,"construction":0.7,"environment":0.7},"has_zh":true},"methods":[{"_id":"6a83ae0eaf14b9c0e7b201ba","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 25,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 25,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,0 – 25,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 25,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 25,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201bb","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)","parameters":[{"name":"Zakres","range":"(1,0 – 12,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (1,0 – 12,5) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1","norm_bases":["PN-ISO 589:2006 Metoda A1"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (1,0 – 12,5) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej)\nZakres (1,0 – 12,5) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (free moisture)","parameters_en":[{"name":"Range","range":"(1,0 – 12,5) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content (free moisture) Gravimetric method Range PN-ISO 589:2006 Metoda A1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,0 – 12,5) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a83ae0eaf14b9c0e7b201bc","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)","parameters":[{"name":"Zakres","range":"(0,8 – 5,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,8 – 5,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1","norm_bases":["PN-ISO 589:2006 Metoda A1"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,8 – 5,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci pozostalej w probce)\nZakres (0,8 – 5,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (moisture remaining in the sample)","parameters_en":[{"name":"Range","range":"(0,8 – 5,0) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (moisture remaining in the sample) Gravimetric method Range PN-ISO 589:2006 Metoda A1","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,8 – 5,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分（样品残余水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A1","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a83ae0eaf14b9c0e7b201bd","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589:2006 Metoda A1","norm_bases":["PN-ISO 589:2006 Metoda A1"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589:2006 Metoda A1 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589:2006 Metoda A1","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 Metoda A1","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-ISO 589:2006 Metoda A1","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a83ae0eaf14b9c0e7b201be","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,7 – 8,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 8,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 8,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,7 – 8,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,7 – 8,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,7 – 8,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201bf","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,0 – 52,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,0 – 52,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,0 – 52,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,0 – 52,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,0 – 52,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 52,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c0","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,30 – 3,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,30 – 3,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,30 – 3,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,30 – 3,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,30 – 3,50) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,30 – 3,50) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c1","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,30 – 3,30) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,30 – 3,30) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"ISO 19579:2006","norm_bases":["ISO 19579:2006"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,30 – 3,30) %\nMetoda wysokotemperaturowego spalania z detekcją IR ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,30 – 3,30) %\nMetoda wysokotemperaturowego spalania z detekcja IR ISO 19579:2006","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,30 – 3,30) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,30 – 3,30) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c2","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru całkowitego","parameters":[{"name":"Zakres","range":"(2,30 – 5,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru całkowitego\nZakres (2,30 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru całkowitego\nZakres (2,30 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru calkowitego\nZakres (2,30 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hydrogen content","parameters_en":[{"name":"Range","range":"(2,30 – 5,00) %"}],"search_en":"Solid fuels: hard coal Total hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(2,30 – 5,00) %"}],"search_zh":"固体燃料：烟煤 全氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"全氢含量"},{"_id":"6a83ae0eaf14b9c0e7b201c3","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(13000 – 33000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (13000 – 33000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (13000 – 33000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (13000 – 33000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(13000 – 33000) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-81/G-04513","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(13000 – 33000) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-81/G-04513","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c4","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513","norm_bases":["PN-81/G-04513"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-81/G-04513 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-81/G-04513","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-81/G-04513","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-81/G-04513","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c5","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(13000 – 33000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (13000 – 33000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (13000 – 33000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (13000 – 33000) kJ/kg\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(13000 – 33000) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(13000 – 33000) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c6","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-ISO 1928:2020-05","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-ISO 1928:2020-05","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c7","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Części lotne","parameters":[{"name":"Zakres","range":"(1,00 – 40,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Części lotne\nZakres (1,00 – 40,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Części lotne\nZakres (1,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Czesci lotne\nZakres (1,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter","parameters_en":[{"name":"Range","range":"(1,00 – 40,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter Gravimetric method Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,00 – 40,00) %"}],"search_zh":"固体燃料：烟煤 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c8","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,7 – 8,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 8,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,7 – 8,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,7 – 8,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,7 – 8,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,7 – 8,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201c9","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,0 – 52,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,0 – 52,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,0 – 52,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,0 – 52,0) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,0 – 52,0) %"}],"search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 52,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201ca","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(33,0 – 85,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (33,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (33,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (33,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(33,0 – 85,0) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(33,0 – 85,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201cb","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda pobierania próbek za pomocą urządzenia mechanicznego","techniques":["Metoda pobierania próbek za pomocą urządzenia mechanicznego"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda pobierania próbek za pomocą urządzenia mechanicznego","reference":"PB-02 wydanie F z dnia 2026-01-27","norm_bases":["PB-02 wydanie F z dnia 2026-01-27"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań fizycznych i chemicznych\nMetoda pobierania próbek za pomocą urządzenia mechanicznego PB-02 wydanie F z dnia 2026-01-27 Paliwa stale: wegiel kamienny Pobieranie probek do badan fizycznych i chemicznych\nMetoda pobierania probek za pomoca urzadzenia mechanicznego PB-02 wydanie F z dnia 2026-01-27","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Solid fuels: hard coal Sampling for physical and chemical testing Sampling method using a mechanical device PB-02 wydanie F z dnia 2026-01-27","technique_en":"Sampling method using a mechanical device","test_object_en":"Solid fuels: hard coal","methodology_zh":"物理与化学检测用样品采集","search_zh":"固体燃料：烟煤 物理与化学检测用样品采集 PB-02 wydanie F z dnia 2026-01-27","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201cc","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.4","norm_bases":["PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.4"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań fizycznych i chemicznych PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.4 Paliwa stale: wegiel kamienny Pobieranie probek do badan fizycznych i chemicznych PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.4","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Solid fuels: hard coal Sampling for physical and chemical testing PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.4","test_object_en":"Solid fuels: hard coal","methodology_zh":"物理与化学检测用样品采集","search_zh":"固体燃料：烟煤 物理与化学检测用样品采集 PN-G-04502:2014-11 p. 5.3.1.3, p. 5.3.1.4","test_object_zh":"固体燃料：烟煤"},{"_id":"6a83ae0eaf14b9c0e7b201cd","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół, żużel, mieszanka popiołowo-żużlowa","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,5 – 35,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,5 – 35,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół, żużel, mieszanka popiołowo-żużlowa Zawartość węgla całkowitego\nZakres (0,5 – 35,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materialy budowlane: popiol, zuzel, mieszanka popiolowo-zuzlowa Zawartosc wegla calkowitego\nZakres (0,5 – 35,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["materials","environment","construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,5 – 35,0) %"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Total carbon content High-temperature combustion with IR detection waste codes according to the Regulation of the Minister of Climate on the waste catalogue Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,5 – 35,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 废物代码依据气候部长关于废物名录的条例 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例"},{"_id":"6a83ae0eaf14b9c0e7b201ce","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(5,0 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (5,0 – 60,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-2:2024-10","norm_bases":["PN-EN ISO 18134-2:2024-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość wilgoci całkowitej\nZakres (5,0 – 60,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10 Paliwa stale: biopaliwo stale – biomasa stala Zawartosc wilgoci calkowitej\nZakres (5,0 – 60,0) %\nMetoda wagowa PN-EN ISO 18134-2:2024-10","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(5,0 – 60,0) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Total moisture content Gravimetric method Range PN-EN ISO 18134-2:2024-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(5,0 – 60,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 全水分含量 重量法 范围 PN-EN ISO 18134-2:2024-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201cf","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(2,5 – 9,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (2,5 – 9,0) %\nMetoda wagowa","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość wilgoci w próbce analitycznej\nZakres (2,5 – 9,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12 Paliwa stale: biopaliwo stale – biomasa stala Zawartosc wilgoci w probce analitycznej\nZakres (2,5 – 9,0) %\nMetoda wagowa PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(2,5 – 9,0) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Moisture content in the analytical sample Gravimetric method Range PN-EN ISO 18134-3:2023-12","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(2,5 – 9,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 分析样品水分含量 重量法 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d0","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,5 – 15,0) %\nMetoda wagowa","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość popiołu\nZakres (0,5 – 15,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05 Paliwa stale: biopaliwo stale – biomasa stala Zawartosc popiolu\nZakres (0,5 – 15,0) %\nMetoda wagowa PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Ash content Gravimetric method Range PN-EN ISO 18122:2023-05","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 灰分含量 重量法 范围 PN-EN ISO 18122:2023-05","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d1","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(14000 – 25000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (14000 – 25000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Ciepło spalania\nZakres (14000 – 25000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07 Paliwa stale: biopaliwo stale – biomasa stala Cieplo spalania\nZakres (14000 – 25000) kJ/kg\nMetoda kalorymetryczna PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(14000 – 25000) kJ/kg"}],"search_en":"Solid fuels: solid biofuel – solid biomass Gross calorific value Calorimetric method Range PN-EN ISO 18125:2017-07","technique_en":"Calorimetric method","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(14000 – 25000) kJ/kg"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 高位发热量 量热法 范围 PN-EN ISO 18125:2017-07","technique_zh":"量热法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d2","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Wartość opałowa (z obliczeń) PN-EN ISO 18125:2017-07 Paliwa stale: biopaliwo stale – biomasa stala Wartosc opalowa (z obliczen) PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: solid biofuel – solid biomass Net calorific value (calculated) PN-EN ISO 18125:2017-07","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：固体生物燃料 － 固体生物质 低位发热量（计算值） PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d3","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(2,5 – 9,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (2,5 – 9,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3:2023-12","norm_bases":["PN-EN ISO 18134-3:2023-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość wilgoci w próbce analitycznej\nZakres (2,5 – 9,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12 Paliwa stale: biopaliwo stale – biomasa stala Zawartosc wilgoci w probce analitycznej\nZakres (2,5 – 9,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3:2023-12","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(2,5 – 9,0) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 18134-3:2023-12","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(2,5 – 9,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 18134-3:2023-12","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d4","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,5 – 15,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122:2023-05","norm_bases":["PN-EN ISO 18122:2023-05"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość popiołu\nZakres (0,5 – 15,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05 Paliwa stale: biopaliwo stale – biomasa stala Zawartosc popiolu\nZakres (0,5 – 15,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122:2023-05","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Ash content Thermogravimetric method (TGA) Range PN-EN ISO 18122:2023-05","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 灰分含量 热重法（TGA） 范围 PN-EN ISO 18122:2023-05","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d5","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,015 – 0,40) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,015 – 0,40) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994:2016-10","norm_bases":["PN-EN ISO 16994:2016-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość siarki całkowitej\nZakres (0,015 – 0,40) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994:2016-10 Paliwa stale: biopaliwo stale – biomasa stala Zawartosc siarki calkowitej\nZakres (0,015 – 0,40) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994:2016-10","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,015 – 0,40) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Total sulfur content High-temperature combustion with IR detection Range PN-EN ISO 16994:2016-10","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,015 – 0,40) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 全硫含量 高温燃烧红外检测法 范围 PN-EN ISO 16994:2016-10","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d6","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(5,00 – 8,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (5,00 – 8,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość wodoru\nZakres (5,00 – 8,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948:2015-07 Paliwa stale: biopaliwo stale – biomasa stala Zawartosc wodoru\nZakres (5,00 – 8,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(5,00 – 8,00) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Hydrogen content High-temperature combustion with IR detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: solid biofuel – solid biomass","parameters_zh":[{"name":"范围","range":"(5,00 – 8,00) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 氢含量 高温燃烧红外检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d7","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego rozpuszczania","parameters":[{"name":"Zakres","range":"(87,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (87,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07 wg zał. B","norm_bases":["PN-EN ISO 21644:2021-07 wg zał. B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (87,0 – 99,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 wg zał. B Paliwa stale: biopaliwo stale – biomasa stala Zawartosc frakcji biodegradowalnej – udzial masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (87,0 – 99,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 wg zal. B","categories":["petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(87,0 – 99,0) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Gravimetric method Range PN-EN ISO 21644:2021-07 wg zał. B","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biofuel – solid biomass","parameters_zh":[{"name":"范围","range":"(87,0 – 99,0) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 重量法 范围 PN-EN ISO 21644:2021-07 wg zał. B","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d8","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń)","reference":"PN-EN ISO 21644:2021-07 wg zał. B","norm_bases":["PN-EN ISO 21644:2021-07 wg zał. B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) PN-EN ISO 21644:2021-07 wg zał. B Paliwa stale: biopaliwo stale – biomasa stala Zawartosc frakcji niebiodegradowalnej – udzial masowy niebiomasy (z obliczen) PN-EN ISO 21644:2021-07 wg zal. B","categories":["petro"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Non-biodegradable fraction content – mass fraction of non-biomass (calculated)","search_en":"Solid fuels: solid biofuel – solid biomass Non-biodegradable fraction content – mass fraction of non-biomass (calculated) PN-EN ISO 21644:2021-07 wg zał. B","test_object_en":"Solid fuels: solid biofuel – solid biomass","search_zh":"固体燃料：固体生物燃料 － 固体生物质 PN-EN ISO 21644:2021-07 wg zał. B","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201d9","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Wytrzymałość mechaniczna","parameters":[{"name":"Zakres","range":"(90,0 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wytrzymałość mechaniczna\nZakres (90,0 – 99,5) %\nMetoda wagowa","reference":"PN-EN ISO 17831-1:2025-10","norm_bases":["PN-EN ISO 17831-1:2025-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Wytrzymałość mechaniczna\nZakres (90,0 – 99,5) %\nMetoda wagowa PN-EN ISO 17831-1:2025-10 Paliwa stale: biopaliwo stale – biomasa stala Wytrzymalosc mechaniczna\nZakres (90,0 – 99,5) %\nMetoda wagowa PN-EN ISO 17831-1:2025-10","categories":["petro"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mechanical strength","parameters_en":[{"name":"Range","range":"(90,0 – 99,5) %"}],"search_en":"Solid fuels: solid biofuel – solid biomass Mechanical strength Gravimetric method Range PN-EN ISO 17831-1:2025-10","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"(90,0 – 99,5) %"}],"search_zh":"固体燃料：固体生物燃料 － 固体生物质 机械强度 重量法 范围 PN-EN ISO 17831-1:2025-10","technique_zh":"重量法","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201da","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: biopaliwo stałe – biomasa stała","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-EN ISO 18135:2017-06 p. 12.3.3.2, p.12.2.2, p.12.2.3.3","norm_bases":["PN-EN ISO 18135:2017-06 p. 12.3.3.2, p.12.2.2, p.12.2.3.3"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: biopaliwo stałe – biomasa stała Pobieranie próbek do badań fizycznych i chemicznych PN-EN ISO 18135:2017-06 p. 12.3.3.2, p.12.2.2, p.12.2.3.3 Paliwa stale: biopaliwo stale – biomasa stala Pobieranie probek do badan fizycznych i chemicznych PN-EN ISO 18135:2017-06 p. 12.3.3.2, p.12.2.2, p.12.2.3.3","categories":["petro"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Solid fuels: solid biofuel – solid biomass Sampling for physical and chemical testing PN-EN ISO 18135:2017-06 p. 12.3.3.2, p.12.2.2, p.12.2.3.3","test_object_en":"Solid fuels: solid biofuel – solid biomass","methodology_zh":"物理与化学检测用样品采集","search_zh":"固体燃料：固体生物燃料 － 固体生物质 物理与化学检测用样品采集 PN-EN ISO 18135:2017-06 p. 12.3.3.2, p.12.2.2, p.12.2.3.3","test_object_zh":"固体燃料：固体生物燃料 － 固体生物质"},{"_id":"6a83ae0eaf14b9c0e7b201db","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(1,0 – 6,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 6,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne Zawartość wilgoci w próbce analitycznej\nZakres (1,0 – 6,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08 Paliwa stale: stale paliwa wtorne Zawartosc wilgoci w probce analitycznej\nZakres (1,0 – 6,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21660-3:2021-08","categories":["petro"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(1,0 – 6,0) %"}],"search_en":"Solid fuels: solid recovered fuels Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-EN ISO 21660-3:2021-08","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid recovered fuels","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 6,0) %"}],"search_zh":"固体燃料：固体回收燃料 分析样品水分含量 热重法（TGA） 范围 PN-EN ISO 21660-3:2021-08","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a83ae0eaf14b9c0e7b201dc","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(5,0 – 30,0) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (5,0 – 30,0) %\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 21656:2021-08","norm_bases":["PN-EN ISO 21656:2021-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne Zawartość popiołu\nZakres (5,0 – 30,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08 Paliwa stale: stale paliwa wtorne Zawartosc popiolu\nZakres (5,0 – 30,0) %\nMetoda termograwimetryczna (TGA) PN-EN ISO 21656:2021-08","categories":["petro"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(5,0 – 30,0) %"}],"search_en":"Solid fuels: solid recovered fuels Ash content Thermogravimetric method (TGA) Range PN-EN ISO 21656:2021-08","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: solid recovered fuels","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(5,0 – 30,0) %"}],"search_zh":"固体燃料：固体回收燃料 灰分含量 热重法（TGA） 范围 PN-EN ISO 21656:2021-08","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a83ae0eaf14b9c0e7b201dd","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne","methodology":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego rozpuszczania","parameters":[{"name":"Zakres","range":"(40,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (40,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN ISO 21644:2021-07 wg zał. B","norm_bases":["PN-EN ISO 21644:2021-07 wg zał. B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne Zawartość frakcji biodegradowalnej – udział masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (40,0 – 95,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 wg zał. B Paliwa stale: stale paliwa wtorne Zawartosc frakcji biodegradowalnej – udzial masowy biomasy z zastosowaniem selektywnego rozpuszczania\nZakres (40,0 – 95,0) %\nMetoda wagowa PN-EN ISO 21644:2021-07 wg zal. B","categories":["petro"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(40,0 – 95,0) %"}],"search_en":"Solid fuels: solid recovered fuels Gravimetric method Range PN-EN ISO 21644:2021-07 wg zał. B","technique_en":"Gravimetric method","test_object_en":"Solid fuels: solid recovered fuels","parameters_zh":[{"name":"范围","range":"(40,0 – 95,0) %"}],"search_zh":"固体燃料：固体回收燃料 重量法 范围 PN-EN ISO 21644:2021-07 wg zał. B","technique_zh":"重量法","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a83ae0eaf14b9c0e7b201de","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Paliwa stałe: stałe paliwa wtórne","methodology":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń)","reference":"PN-EN ISO 21644:2021-07 wg zał. B","norm_bases":["PN-EN ISO 21644:2021-07 wg zał. B"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: stałe paliwa wtórne Zawartość frakcji niebiodegradowalnej – udział masowy niebiomasy (z obliczeń) PN-EN ISO 21644:2021-07 wg zał. B Paliwa stale: stale paliwa wtorne Zawartosc frakcji niebiodegradowalnej – udzial masowy niebiomasy (z obliczen) PN-EN ISO 21644:2021-07 wg zal. B","categories":["petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Non-biodegradable fraction content – mass fraction of non-biomass (calculated)","search_en":"Solid fuels: solid recovered fuels Non-biodegradable fraction content – mass fraction of non-biomass (calculated) PN-EN ISO 21644:2021-07 wg zał. B","test_object_en":"Solid fuels: solid recovered fuels","search_zh":"固体燃料：固体回收燃料 PN-EN ISO 21644:2021-07 wg zał. B","test_object_zh":"固体燃料：固体回收燃料"},{"_id":"6a83ae0eaf14b9c0e7b201df","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu","methodology":"Stężenie aktywności radionuklidu: 40K","parameters":[{"name":"Zakres","range":"(600 − 1200) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 40K\nZakres (600 − 1200) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB-10 wydanie B z dnia 2021-12-10","norm_bases":["PB-10 wydanie B z dnia 2021-12-10"],"lab_section":null,"lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu Stężenie aktywności radionuklidu: 40K\nZakres (600 − 1200) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-10 wydanie B z dnia 2021-12-10 Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materialy budowlane: popiol lotny do betonu Stezenie aktywnosci radionuklidu: 40K\nZakres (600 − 1200) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-10 wydanie B z dnia 2021-12-10","categories":["construction","materials","environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration of the radionuclide: 40K","parameters_en":[{"name":"Range","range":"(600 − 1200) Bq/kg"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete Activity concentration of the radionuclide: 40K Gamma-ray spectrometry method waste codes according to the Regulation of the Minister of Climate on the waste catalogue Range PB-10 wydanie B z dnia 2021-12-10","technique_en":"Gamma-ray spectrometry method","test_object_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete","parameters_zh":[{"name":"范围","range":"(600 − 1200) Bq/kg"}],"search_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰 γ 能谱法 废物代码依据气候部长关于废物名录的条例 范围 PB-10 wydanie B z dnia 2021-12-10","technique_zh":"γ 能谱法","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例","test_object_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰"},{"_id":"6a83ae0eaf14b9c0e7b201e0","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu","methodology":"Stężenie aktywności radionuklidu: 214Bi","parameters":[{"name":"Zakres","range":"(80 − 180) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 214Bi\nZakres (80 − 180) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB-10 wydanie B z dnia 2021-12-10","norm_bases":["PB-10 wydanie B z dnia 2021-12-10"],"lab_section":null,"lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu Stężenie aktywności radionuklidu: 214Bi\nZakres (80 − 180) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-10 wydanie B z dnia 2021-12-10 Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materialy budowlane: popiol lotny do betonu Stezenie aktywnosci radionuklidu: 214Bi\nZakres (80 − 180) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-10 wydanie B z dnia 2021-12-10","categories":["construction","materials","environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration of radionuclide: 214Bi","parameters_en":[{"name":"Range","range":"(80 − 180) Bq/kg"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete Activity concentration of radionuclide: 214Bi Gamma-ray spectrometry method waste codes according to the Regulation of the Minister of Climate on the waste catalogue Range PB-10 wydanie B z dnia 2021-12-10","technique_en":"Gamma-ray spectrometry method","test_object_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete","parameters_zh":[{"name":"范围","range":"(80 − 180) Bq/kg"}],"search_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰 放射性核素活度浓度：214Bi γ 能谱法 废物代码依据气候部长关于废物名录的条例 范围 PB-10 wydanie B z dnia 2021-12-10","technique_zh":"γ 能谱法","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例","test_object_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰","methodology_zh":"放射性核素活度浓度：214Bi"},{"_id":"6a83ae0eaf14b9c0e7b201e1","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu","methodology":"Stężenie aktywności radionuklidu: 208Tl","parameters":[{"name":"Zakres","range":"(60 − 130) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu: 208Tl\nZakres (60 − 130) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB-10 wydanie B z dnia 2021-12-10","norm_bases":["PB-10 wydanie B z dnia 2021-12-10"],"lab_section":null,"lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu Stężenie aktywności radionuklidu: 208Tl\nZakres (60 − 130) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-10 wydanie B z dnia 2021-12-10 Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materialy budowlane: popiol lotny do betonu Stezenie aktywnosci radionuklidu: 208Tl\nZakres (60 − 130) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-10 wydanie B z dnia 2021-12-10","categories":["construction","materials","environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration of radionuclide: 208Tl","parameters_en":[{"name":"Range","range":"(60 − 130) Bq/kg"}],"regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete Activity concentration of radionuclide: 208Tl Gamma-ray spectrometry method waste codes according to the Regulation of the Minister of Climate on the waste catalogue Range PB-10 wydanie B z dnia 2021-12-10","technique_en":"Gamma-ray spectrometry method","test_object_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete","parameters_zh":[{"name":"范围","range":"(60 − 130) Bq/kg"}],"search_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰 放射性核素活度浓度：208Tl γ 能谱法 废物代码依据气候部长关于废物名录的条例 范围 PB-10 wydanie B z dnia 2021-12-10","technique_zh":"γ 能谱法","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例","test_object_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰","methodology_zh":"放射性核素活度浓度：208Tl"},{"_id":"6a83ae0eaf14b9c0e7b201e2","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu","methodology":"Stężenie aktywności radionuklidu: 226Ra (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie aktywności radionuklidu: 226Ra (z obliczeń)","reference":"PB-10 wydanie B z dnia 2021-12-10","norm_bases":["PB-10 wydanie B z dnia 2021-12-10"],"lab_section":null,"lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu Stężenie aktywności radionuklidu: 226Ra (z obliczeń) PB-10 wydanie B z dnia 2021-12-10 Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materialy budowlane: popiol lotny do betonu Stezenie aktywnosci radionuklidu: 226Ra (z obliczen) PB-10 wydanie B z dnia 2021-12-10","categories":["construction","materials","environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radionuclide activity concentration: 226Ra (calculated)","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete Radionuclide activity concentration: 226Ra (calculated) waste codes according to the Regulation of the Minister of Climate on the waste catalogue PB-10 wydanie B z dnia 2021-12-10","test_object_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete","methodology_zh":"放射性核素活度浓度：226Ra（计算得出）","search_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰 放射性核素活度浓度：226Ra（计算得出） 废物代码依据气候部长关于废物名录的条例 PB-10 wydanie B z dnia 2021-12-10","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例","test_object_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰"},{"_id":"6a83ae0eaf14b9c0e7b201e3","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu","methodology":"Stężenie aktywności radionuklidu: 232Th (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie aktywności radionuklidu: 232Th (z obliczeń)","reference":"PB-10 wydanie B z dnia 2021-12-10","norm_bases":["PB-10 wydanie B z dnia 2021-12-10"],"lab_section":null,"lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu Stężenie aktywności radionuklidu: 232Th (z obliczeń) PB-10 wydanie B z dnia 2021-12-10 Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materialy budowlane: popiol lotny do betonu Stezenie aktywnosci radionuklidu: 232Th (z obliczen) PB-10 wydanie B z dnia 2021-12-10","categories":["construction","materials","environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Radionuclide activity concentration: 232Th (calculated)","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete Radionuclide activity concentration: 232Th (calculated) waste codes according to the Regulation of the Minister of Climate on the waste catalogue PB-10 wydanie B z dnia 2021-12-10","test_object_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete","methodology_zh":"放射性核素活度浓度：232Th（计算得出）","search_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰 放射性核素活度浓度：232Th（计算得出） 废物代码依据气候部长关于废物名录的条例 PB-10 wydanie B z dnia 2021-12-10","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例","test_object_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰"},{"_id":"6a83ae0eaf14b9c0e7b201e4","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu","methodology":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik stężenia promieniotwórczego I (z obliczeń)","reference":"PB-10 wydanie B z dnia 2021-12-10","norm_bases":["PB-10 wydanie B z dnia 2021-12-10"],"lab_section":null,"lab_address":null,"regulatory_area":"kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materiały budowlane: popiół lotny do betonu Wskaźnik stężenia promieniotwórczego I (z obliczeń) PB-10 wydanie B z dnia 2021-12-10 Odpady o): kod 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Materialy budowlane: popiol lotny do betonu Wskaznik stezenia promieniotworczego I (z obliczen) PB-10 wydanie B z dnia 2021-12-10","categories":["construction","materials","environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration index I (calculated)","regulatory_area_en":"waste codes according to the Regulation of the Minister of Climate on the waste catalogue","search_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete Activity concentration index I (calculated) waste codes according to the Regulation of the Minister of Climate on the waste catalogue PB-10 wydanie B z dnia 2021-12-10","test_object_en":"Waste o): code 10 01 01, 10 01 02, 10 01 15, 10 01 17, 10 01 80, Building materials: fly ash for concrete","methodology_zh":"放射性浓度指数 I（计算得出）","search_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰 放射性浓度指数 I（计算得出） 废物代码依据气候部长关于废物名录的条例 PB-10 wydanie B z dnia 2021-12-10","regulatory_area_zh":"废物代码依据气候部长关于废物名录的条例","test_object_zh":"废物 o)：代码 10 01 01、10 01 02、10 01 15、10 01 17、10 01 80；建筑材料：用于混凝土的粉煤灰"},{"_id":"6a83ae0eaf14b9c0e7b201e5","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(0,010 – 60,0) mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (0,010 – 60,0) mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (0,010 – 60,0) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (0,010 – 60,0) mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(0,010 – 60,0) mS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(0,010 – 60,0) mS/cm"}],"search_zh":"水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、污水"},{"_id":"6a83ae0eaf14b9c0e7b201e6","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a83ae0eaf14b9c0e7b201e7","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 5000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83ae0eaf14b9c0e7b201e8","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(100 – 50000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (100 – 50000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone\nZakres (100 – 50000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Substancje rozpuszczone\nZakres (100 – 50000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(100 – 50000) mg/l"}],"search_en":"Water, Wastewater Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(100 – 50000) mg/l"}],"search_zh":"水、污水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性固体"},{"_id":"6a83ae0eaf14b9c0e7b201e9","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - SP-ChZT","parameters":[{"name":"Zakres","range":"(5,00 – 600) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - SP-ChZT\nZakres (5,00 – 600) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - SP-ChZT\nZakres (5,00 – 600) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - SP-ChZT\nZakres (5,00 – 600) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - SP-COD","parameters_en":[{"name":"Range","range":"(5,00 – 600) mg/l"}],"search_en":"Water, Wastewater Chemical oxygen demand - SP-COD Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(5,00 – 600) mg/l"}],"search_zh":"水、污水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83ae0eaf14b9c0e7b201ea","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie metali:","parameters":[{"name":"srebro","range":"(5,0 – 300) μg/l"},{"name":"glin","range":"(20,0 – 300) μg/l"},{"name":"bor","range":"(0,030 – 90,00) mg/l"},{"name":"kadm","range":"(4,0 – 300) μg/l"},{"name":"miedź","range":"(5,0 – 300) μg/l"},{"name":"chrom","range":"(9,0 – 300) μg/l"},{"name":"żelazo","range":"(19,0 – 300) μg/l"},{"name":"mangan","range":"(3,0 – 300) μg/l"},{"name":"nikiel","range":"(16,0 – 300) μg/l"},{"name":"ołów","range":"(11,0 – 300) μg/l"},{"name":"wanad","range":"(6,0 – 300) μg/l"},{"name":"cynk","range":"(5,0 – 300) μg/l"},{"name":"arsen","range":"(13,0 – 300) μg/l"}],"technique":"Metoda optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nsrebro (5,0 – 300) μg/l\nglin (20,0 – 300) μg/l\nbor (0,030 – 90,00) mg/l\nkadm (4,0 – 300) μg/l\nmiedź (5,0 – 300) μg/l\nchrom (9,0 – 300) μg/l\nżelazo (19,0 – 300) μg/l\nmangan (3,0 – 300) μg/l\nnikiel (16,0 – 300) μg/l\nołów (11,0 – 300) μg/l\nwanad (6,0 – 300) μg/l\ncynk (5,0 – 300) μg/l\narsen (13,0 – 300) μg/l\nMetoda optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie metali:\nZakres:\nsrebro (5,0 – 300) μg/l\nglin (20,0 – 300) μg/l\nbor (0,030 – 90,00) mg/l\nkadm (4,0 – 300) μg/l\nmiedź (5,0 – 300) μg/l\nchrom (9,0 – 300) μg/l\nżelazo (19,0 – 300) μg/l\nmangan (3,0 – 300) μg/l\nnikiel (16,0 – 300) μg/l\nołów (11,0 – 300) μg/l\nwanad (6,0 – 300) μg/l\ncynk (5,0 – 300) μg/l\narsen (13,0 – 300) μg/l\nMetoda optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie metali:\nZakres:\nsrebro (5,0 – 300) μg/l\nglin (20,0 – 300) μg/l\nbor (0,030 – 90,00) mg/l\nkadm (4,0 – 300) μg/l\nmiedz (5,0 – 300) μg/l\nchrom (9,0 – 300) μg/l\nzelazo (19,0 – 300) μg/l\nmangan (3,0 – 300) μg/l\nnikiel (16,0 – 300) μg/l\nolow (11,0 – 300) μg/l\nwanad (6,0 – 300) μg/l\ncynk (5,0 – 300) μg/l\narsen (13,0 – 300) μg/l\nMetoda optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"silver","range":"(5,0 – 300) μg/l"},{"name":"aluminium","range":"(20,0 – 300) μg/l"},{"name":"boron","range":"(0,030 – 90,00) mg/l"},{"name":"cadmium","range":"(4,0 – 300) μg/l"},{"name":"copper","range":"(5,0 – 300) μg/l"},{"name":"chromium","range":"(9,0 – 300) μg/l"},{"name":"iron","range":"(19,0 – 300) μg/l"},{"name":"manganese","range":"(3,0 – 300) μg/l"},{"name":"nickel","range":"(16,0 – 300) μg/l"},{"name":"lead","range":"(11,0 – 300) μg/l"},{"name":"vanadium","range":"(6,0 – 300) μg/l"},{"name":"zinc","range":"(5,0 – 300) μg/l"},{"name":"arsenic","range":"(13,0 – 300) μg/l"}],"search_en":"Water, Wastewater Metal concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) silver aluminium boron cadmium copper chromium iron manganese nickel lead vanadium zinc arsenic PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"银","range":"(5,0 – 300) μg/l"},{"name":"铝","range":"(20,0 – 300) μg/l"},{"name":"硼","range":"(0,030 – 90,00) mg/l"},{"name":"镉","range":"(4,0 – 300) μg/l"},{"name":"铜","range":"(5,0 – 300) μg/l"},{"name":"铬","range":"(9,0 – 300) μg/l"},{"name":"铁","range":"(19,0 – 300) μg/l"},{"name":"锰","range":"(3,0 – 300) μg/l"},{"name":"镍","range":"(16,0 – 300) μg/l"},{"name":"铅","range":"(11,0 – 300) μg/l"},{"name":"钒","range":"(6,0 – 300) μg/l"},{"name":"锌","range":"(5,0 – 300) μg/l"},{"name":"砷","range":"(13,0 – 300) μg/l"}],"search_zh":"水、污水 金属浓度： 银 铝 硼 镉 铜 铬 铁 锰 镍 铅 钒 锌 砷 PN-EN ISO 11885:2009","test_object_zh":"水、污水","methodology_zh":"金属浓度："},{"_id":"6a83ae0eaf14b9c0e7b201eb","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(20 – 30000) mg/l"},{"name":"Siarczany","range":"(50 – 3000) mg/l"},{"name":"Fluorki","range":"(0,30 – 25) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (20 – 30000) mg/l\nSiarczany (50 – 3000) mg/l\nFluorki (0,30 – 25) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie anionów\nZakres:\nChlorki (20 – 30000) mg/l\nSiarczany (50 – 3000) mg/l\nFluorki (0,30 – 25) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow\nZakres:\nChlorki (20 – 30000) mg/l\nSiarczany (50 – 3000) mg/l\nFluorki (0,30 – 25) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(20 – 30000) mg/l"},{"name":"Sulfates","range":"(50 – 3000) mg/l"},{"name":"Fluorides","range":"(0,30 – 25) mg/l"}],"search_en":"Water, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorides Sulfates Fluorides PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(20 – 30000) mg/l"},{"name":"硫酸盐","range":"(50 – 3000) mg/l"},{"name":"氟化物","range":"(0,30 – 25) mg/l"}],"search_zh":"水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硫酸盐 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a83ae0eaf14b9c0e7b201ec","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Water intended for human consumption Sampling for physical and chemical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"物理与化学检测用样品采集","search_zh":"生活饮用水 物理与化学检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a83ae0eaf14b9c0e7b201ed","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań fizycznych i chemicznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6 Woda Pobieranie probek do badan fizycznych i chemicznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.3, 7.5, 7.6","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Water Sampling for physical and chemical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6","test_object_en":"Water","methodology_zh":"物理与化学检测用样品采集","search_zh":"水 物理与化学检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.3, 7.5, 7.6","test_object_zh":"水"},{"_id":"6a83ae0eaf14b9c0e7b201ee","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(-0,5 – 35) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (-0,5 – 35) ºC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (-0,5 – 35) ºC PN-77/C-04584 Woda Temperatura\nZakres (-0,5 – 35) ºC PN-77/C-04584","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(-0,5 – 35) ºC"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(-0,5 – 35) ºC"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a83ae0eaf14b9c0e7b201ef","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Wastewater Sampling for physical and chemical testing Manual and automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"物理与化学检测用样品采集","search_zh":"污水 物理与化学检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a83ae0eaf14b9c0e7b201f0","lab_id":"69ad52a3de79e566650fb3ba","country":"PL","accr_number":"AB 743","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(-0,5 – 35) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (-0,5 – 35) ºC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (-0,5 – 35) ºC PN-77/C-04584 Scieki Temperatura\nZakres (-0,5 – 35) ºC PN-77/C-04584","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(-0,5 – 35) ºC"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(-0,5 – 35) ºC"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"}],"has_pdf":true}