{"lab":{"_id":"69ad52a3de79e566650fb3b6","accr_number":"AB 740","country":"PL","accr_body":"PCA","address":"LABORATORIUM CHEMII ŚRODOWISKA PRZYRODNICZEGO, ul. Braci Leśnej 3, Sękocin Stary, 05 - 090 Raszyn","categories":["water","environment","materials"],"city":"Raszyn","imported_at":"2026-03-08T10:42:43.265Z","methods_count":15,"name":"INSTYTUT BADAWCZY LEŚNICTWA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_740.pdf"],"scope_summary":"","search_text":"instytut badawczy leśnictwa laboratorium chemii środowiska przyrodniczego, ul. braci leśnej 3, sękocin stary, 05 - 090 raszyn water pharma electronics other environment","status":"active","updated_at":"2026-03-08T14:51:37.828Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T00:55:01.752Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.ibles.pl/artykul/102/27/dane-podstawowe","fields_of_testing":[{"codes":"C/3","pl":"Badania chemiczne obiektów i materiałów biologicznych","en":"Chemical tests of biological items and materials for testing"},{"codes":"C/28, C/31","pl":"Badania chemiczne wody, gleby","en":"Chemical tests of water, soil"},{"codes":"N/28, N/31","pl":"Badania właściwości fizycznych wody, gleby","en":"Tests of physical properties of water, soil"}],"issue":{"no":"19","date":"02.06.2026"},"parse_date":"2026-08-18T00:55:01.752Z","parse_source":"agent-claude-code","map_coord":[52.101115,20.881238],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM CHEMII ŚRODOWISKA PRZYRODNICZEGO","address":"ul. Braci Leśnej 3, Sękocin Stary","city":"Raszyn","postal":"05 - 090"},{"name":"Laboratorium Chemii Środowiska Przyrodniczego","address":"ul. Braci Leśnej 3 Sękocin Stary","city":"Raszyn","postal":"05 - 090"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/da78dbc7db089c15e4df998d5144e7b1/AB%20740.pdf","has_en":true,"category_counts":{"water":8,"environment":6,"materials":2},"category_scores":{"water":4,"environment":2.25,"materials":0.25},"has_zh":true},"methods":[{"_id":"6a83ad65af14b9c0e7b20180","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 8,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 8,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda pH\nZakres 4,0 – 8,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres 4,0 – 8,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 8,0"}],"search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 8,0"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a83ad65af14b9c0e7b20181","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 – 1413) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10,0 – 1413) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (10,0 – 1413) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (10,0 – 1413) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 – 1413) µS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 – 1413) µS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a83ad65af14b9c0e7b20182","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów","parameters":[{"name":"Cl‾","range":"(0,03 – 100) mg/l"},{"name":"NO3‾","range":"(0,08 – 100) mg/l"},{"name":"SO42‾","range":"(0,09 – 200) mg/l"},{"name":"PO4³‾","range":"(0,13 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nCl‾ (0,03 – 100) mg/l\nNO3‾ (0,08 – 100) mg/l\nSO42‾ (0,09 – 200) mg/l\nPO4³‾ (0,13 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów\nZakres:\nCl‾ (0,03 – 100) mg/l\nNO3‾ (0,08 – 100) mg/l\nSO42‾ (0,09 – 200) mg/l\nPO4³‾ (0,13 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda Stezenie anionow\nZakres:\nCl‾ (0,03 – 100) mg/l\nNO3‾ (0,08 – 100) mg/l\nSO42‾ (0,09 – 200) mg/l\nPO4³‾ (0,13 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） PN-EN ISO 10304-1:2009","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a83ad65af14b9c0e7b20183","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie kationu amonowego","parameters":[{"name":"NH4+","range":"(0,08 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationu amonowego\nNH4+ (0,08 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie kationu amonowego\nNH4+ (0,08 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda Stezenie kationu amonowego\nNH4+ (0,08 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium cation concentration","parameters_en":[{"name":"NH4+","range":"(0,08 – 100) mg/l"}],"search_en":"Water Ammonium cation concentration Ion chromatography with conductometric detection (IC-CD) NH4+ PN-EN ISO 14911:2002","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","search_zh":"水 离子色谱-电导检测法（IC-CD） PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水"},{"_id":"6a83ad65af14b9c0e7b20184","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pierwiastków","parameters":[{"name":"Ca","range":"(0,10 – 100) mg/l"},{"name":"Mg","range":"(0,005 – 20) mg/l"},{"name":"Na","range":"(0,10 – 50) mg/l"},{"name":"K","range":"(0,40 – 50) mg/l"},{"name":"Fe","range":"(0,003 – 4) mg/l"},{"name":"Al","range":"(0,018 – 5) mg/l"},{"name":"Mn","range":"(0,001 – 5) mg/l"},{"name":"Zn","range":"(0,005 – 2) mg/l"},{"name":"Cu","range":"(0,009 – 1) mg/l"},{"name":"Cd","range":"(0,0005 – 0,5) mg/l"},{"name":"Pb","range":"(0,010 – 0,5) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nCa (0,10 – 100) mg/l\nMg (0,005 – 20) mg/l\nNa (0,10 – 50) mg/l\nK (0,40 – 50) mg/l\nFe (0,003 – 4) mg/l\nAl (0,018 – 5) mg/l\nMn (0,001 – 5) mg/l\nZn (0,005 – 2) mg/l\nCu (0,009 – 1) mg/l\nCd (0,0005 – 0,5) mg/l\nPb (0,010 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pierwiastków\nZakres:\nCa (0,10 – 100) mg/l\nMg (0,005 – 20) mg/l\nNa (0,10 – 50) mg/l\nK (0,40 – 50) mg/l\nFe (0,003 – 4) mg/l\nAl (0,018 – 5) mg/l\nMn (0,001 – 5) mg/l\nZn (0,005 – 2) mg/l\nCu (0,009 – 1) mg/l\nCd (0,0005 – 0,5) mg/l\nPb (0,010 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie pierwiastkow\nZakres:\nCa (0,10 – 100) mg/l\nMg (0,005 – 20) mg/l\nNa (0,10 – 50) mg/l\nK (0,40 – 50) mg/l\nFe (0,003 – 4) mg/l\nAl (0,018 – 5) mg/l\nMn (0,001 – 5) mg/l\nZn (0,005 – 2) mg/l\nCu (0,009 – 1) mg/l\nCd (0,0005 – 0,5) mg/l\nPb (0,010 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Ca","range":"(0,10 – 100) mg/l"},{"name":"Mg","range":"(0,005 – 20) mg/l"},{"name":"Na","range":"(0,10 – 50) mg/l"},{"name":"K","range":"(0,40 – 50) mg/l"},{"name":"Fe","range":"(0,003 – 4) mg/l"},{"name":"Al","range":"(0,018 – 5) mg/l"},{"name":"Mn","range":"(0,001 – 5) mg/l"},{"name":"Zn","range":"(0,005 – 2) mg/l"},{"name":"Cu","range":"(0,009 – 1) mg/l"},{"name":"Cd","range":"(0,0005 – 0,5) mg/l"},{"name":"Pb","range":"(0,010 – 0,5) mg/l"}],"search_en":"Water Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Ca Mg Na K Fe Al Mn Zn Cu Cd Pb PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","methodology_zh":"元素浓度","parameters_zh":[{"name":"Ca","range":"(0,10 – 100) mg/l"},{"name":"Mg","range":"(0,005 – 20) mg/l"},{"name":"Na","range":"(0,10 – 50) mg/l"},{"name":"K","range":"(0,40 – 50) mg/l"},{"name":"Fe","range":"(0,003 – 4) mg/l"},{"name":"Al","range":"(0,018 – 5) mg/l"},{"name":"Mn","range":"(0,001 – 5) mg/l"},{"name":"Zn","range":"(0,005 – 2) mg/l"},{"name":"Cu","range":"(0,009 – 1) mg/l"},{"name":"Cd","range":"(0,0005 – 0,5) mg/l"},{"name":"Pb","range":"(0,010 – 0,5) mg/l"}],"search_zh":"水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Ca Mg Na K Fe Al Mn Zn Cu Cd Pb PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水"},{"_id":"6a83ad65af14b9c0e7b20185","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rozpuszczonego węgla organicznego (RWO)","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/l"}],"technique":"Metoda spektrofotometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrofotometrii w zakresie podczerwieni (IR)"],"computed":[],"activity":"Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres (1,0 – 500) mg/l\nMetoda spektrofotometrii w zakresie podczerwieni (IR)","reference":"PN-EN ISO 20236:2022-04","norm_bases":["PN-EN ISO 20236:2022-04"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rozpuszczonego węgla organicznego (RWO)\nZakres (1,0 – 500) mg/l\nMetoda spektrofotometrii w zakresie podczerwieni (IR) PN-EN ISO 20236:2022-04 Woda Stezenie rozpuszczonego wegla organicznego (RWO)\nZakres (1,0 – 500) mg/l\nMetoda spektrofotometrii w zakresie podczerwieni (IR) PN-EN ISO 20236:2022-04","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon (DOC) concentration","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/l"}],"search_en":"Water Dissolved organic carbon (DOC) concentration Infrared spectrophotometry method (IR) Range PN-EN ISO 20236:2022-04","technique_en":"Infrared spectrophotometry method (IR)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/l"}],"search_zh":"水 溶解性有机碳（DOC）浓度 范围 PN-EN ISO 20236:2022-04","test_object_zh":"水","methodology_zh":"溶解性有机碳（DOC）浓度"},{"_id":"6a83ad65af14b9c0e7b20186","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rozpuszczonego azotu związanego – DNb(N)","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"computed":[],"activity":"Stężenie rozpuszczonego azotu związanego – DNb(N)\nZakres (1,0 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2022-04","norm_bases":["PN-EN ISO 20236:2022-04"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rozpuszczonego azotu związanego – DNb(N)\nZakres (1,0 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2022-04 Woda Stezenie rozpuszczonego azotu zwiazanego – DNb(N)\nZakres (1,0 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2022-04","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved bound nitrogen concentration – DNb(N)","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/l"}],"search_en":"Water Dissolved bound nitrogen concentration – DNb(N) High-temperature combustion with chemiluminescence detection Range PN-EN ISO 20236:2022-04","technique_en":"High-temperature combustion with chemiluminescence detection","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/l"}],"search_zh":"水 高温燃烧-化学发光检测法 范围 PN-EN ISO 20236:2022-04","test_object_zh":"水","technique_zh":"高温燃烧-化学发光检测法"},{"_id":"6a83ad65af14b9c0e7b20187","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Gleba","methodology":"pH - w KCI, w H2O oraz CaCl2","parameters":[{"name":"Zakres","range":"2,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w KCI, w H2O oraz CaCl2\nZakres 2,0 – 9,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH - w KCI, w H2O oraz CaCl2\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w KCI, w H2O oraz CaCl2\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in KCI, in H2O and CaCl2","parameters_en":[{"name":"Range","range":"2,0 – 9,0"}],"search_en":"Soil pH - in KCI, in H2O and CaCl2 Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"2,0 – 9,0"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a83ad65af14b9c0e7b20188","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,1 – 30,0) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TCD","techniques":["Metoda wysokotemperaturowego spalania z detekcją TCD"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres (0,1 – 30,0) g/kg\nMetoda wysokotemperaturowego spalania z detekcją TCD","reference":"PN-ISO 13878:2002","norm_bases":["PN-ISO 13878:2002"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość azotu ogólnego\nZakres (0,1 – 30,0) g/kg\nMetoda wysokotemperaturowego spalania z detekcją TCD PN-ISO 13878:2002 Gleba Zawartosc azotu ogolnego\nZakres (0,1 – 30,0) g/kg\nMetoda wysokotemperaturowego spalania z detekcja TCD PN-ISO 13878:2002","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(0,1 – 30,0) g/kg"}],"search_en":"Soil Total nitrogen content High-temperature combustion with TCD detection Range PN-ISO 13878:2002","technique_en":"High-temperature combustion with TCD detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,1 – 30,0) g/kg"}],"search_zh":"土壤 总氮含量 高温燃烧热导检测法（TCD） 范围 PN-ISO 13878:2002","test_object_zh":"土壤","methodology_zh":"总氮含量","technique_zh":"高温燃烧热导检测法（TCD）"},{"_id":"6a83ad65af14b9c0e7b20189","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość węgla ogólnego","parameters":[{"name":"Zakres","range":"(0,1 – 600) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TCD","techniques":["Metoda wysokotemperaturowego spalania z detekcją TCD"],"computed":[],"activity":"Zawartość węgla ogólnego\nZakres (0,1 – 600) g/kg\nMetoda wysokotemperaturowego spalania z detekcją TCD","reference":"PN-ISO 10694:2002","norm_bases":["PN-ISO 10694:2002"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość węgla ogólnego\nZakres (0,1 – 600) g/kg\nMetoda wysokotemperaturowego spalania z detekcją TCD PN-ISO 10694:2002 Gleba Zawartosc wegla ogolnego\nZakres (0,1 – 600) g/kg\nMetoda wysokotemperaturowego spalania z detekcja TCD PN-ISO 10694:2002","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,1 – 600) g/kg"}],"search_en":"Soil Total carbon content High-temperature combustion with TCD detection Range PN-ISO 10694:2002","technique_en":"High-temperature combustion with TCD detection","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,1 – 600) g/kg"}],"search_zh":"土壤 高温燃烧热导检测法（TCD） 范围 PN-ISO 10694:2002","test_object_zh":"土壤","technique_zh":"高温燃烧热导检测法（TCD）"},{"_id":"6a83ad65af14b9c0e7b2018a","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa / zawartość wody","parameters":[{"name":"Zakres","range":"(0,1 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa / zawartość wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999 Gleba Sucha masa / zawartosc wody\nZakres (0,1 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter / water content","parameters_en":[{"name":"Range","range":"(0,1 – 99,9) %"}],"search_en":"Soil Dry matter / water content Gravimetric method Range PN-ISO 11465:1999","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,1 – 99,9) %"}],"search_zh":"土壤 干物质 / 水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","test_object_zh":"土壤","methodology_zh":"干物质 / 水分含量"},{"_id":"6a83ad65af14b9c0e7b2018b","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Gleba","methodology":"Skład granulometryczny","parameters":[{"name":"Zakres","range":"(0,01 – 100) %"}],"technique":"Metoda sedymentacyjna (pipetowa)","techniques":["Metoda sedymentacyjna (pipetowa)"],"computed":[],"activity":"Skład granulometryczny\nZakres (0,01 – 100) %\nMetoda sedymentacyjna (pipetowa)","reference":"PN-ISO 11277:2005","norm_bases":["PN-ISO 11277:2005"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Skład granulometryczny\nZakres (0,01 – 100) %\nMetoda sedymentacyjna (pipetowa) PN-ISO 11277:2005 Gleba Sklad granulometryczny\nZakres (0,01 – 100) %\nMetoda sedymentacyjna (pipetowa) PN-ISO 11277:2005","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution","parameters_en":[{"name":"Range","range":"(0,01 – 100) %"}],"search_en":"Soil Particle size distribution Sedimentation method (pipette) Range PN-ISO 11277:2005","technique_en":"Sedimentation method (pipette)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(0,01 – 100) %"}],"search_zh":"土壤 粒度组成 范围 PN-ISO 11277:2005","test_object_zh":"土壤","methodology_zh":"粒度组成"},{"_id":"6a83ad65af14b9c0e7b2018c","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość pierwiastków","parameters":[{"name":"Cd","range":"(1,0 – 20) mg/kg"},{"name":"Cr","range":"(3,0 – 500) mg/kg"},{"name":"Cu","range":"(5,0 – 500) mg/kg"},{"name":"Ni","range":"(2,5 – 250) mg/kg"},{"name":"Pb","range":"(2,5 – 500) mg/kg"},{"name":"Zn","range":"(10 – 1000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCd (1,0 – 20) mg/kg\nCr (3,0 – 500) mg/kg\nCu (5,0 – 500) mg/kg\nNi (2,5 – 250) mg/kg\nPb (2,5 – 500) mg/kg\nZn (10 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-ISO 11466:2002 | PN-EN ISO 11885:2009","norm_bases":["PN-ISO 11466:2002","PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość pierwiastków\nZakres:\nCd (1,0 – 20) mg/kg\nCr (3,0 – 500) mg/kg\nCu (5,0 – 500) mg/kg\nNi (2,5 – 250) mg/kg\nPb (2,5 – 500) mg/kg\nZn (10 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-ISO 11466:2002 | PN-EN ISO 11885:2009 Gleba Zawartosc pierwiastkow\nZakres:\nCd (1,0 – 20) mg/kg\nCr (3,0 – 500) mg/kg\nCu (5,0 – 500) mg/kg\nNi (2,5 – 250) mg/kg\nPb (2,5 – 500) mg/kg\nZn (10 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-ISO 11466:2002 | PN-EN ISO 11885:2009","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Cd","range":"(1,0 – 20) mg/kg"},{"name":"Cr","range":"(3,0 – 500) mg/kg"},{"name":"Cu","range":"(5,0 – 500) mg/kg"},{"name":"Ni","range":"(2,5 – 250) mg/kg"},{"name":"Pb","range":"(2,5 – 500) mg/kg"},{"name":"Zn","range":"(10 – 1000) mg/kg"}],"search_en":"Soil Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Cd Cr Cu Ni Pb Zn PN-ISO 11466:2002 | PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil","methodology_zh":"元素含量","parameters_zh":[{"name":"Cd","range":"(1,0 – 20) mg/kg"},{"name":"Cr","range":"(3,0 – 500) mg/kg"},{"name":"Cu","range":"(5,0 – 500) mg/kg"},{"name":"Ni","range":"(2,5 – 250) mg/kg"},{"name":"Pb","range":"(2,5 – 500) mg/kg"},{"name":"Zn","range":"(10 – 1000) mg/kg"}],"search_zh":"土壤 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） Cd Cr Cu Ni Pb Zn PN-ISO 11466:2002 | PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤"},{"_id":"6a83ad65af14b9c0e7b2018d","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość azotu ogólnego i węgla ogólnego","parameters":[{"name":"N","range":"(4,0 – 50,0) g/kg"},{"name":"C","range":"(320 – 600) g/kg"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TCD","techniques":["Metoda wysokotemperaturowego spalania z detekcją TCD"],"computed":[],"activity":"Zawartość azotu ogólnego i węgla ogólnego\nZakres:\nN (4,0 – 50,0) g/kg\nC (320 – 600) g/kg\nMetoda wysokotemperaturowego spalania z detekcją TCD","reference":"PB-04 edycja 9 z dnia 02.11.2023 r.","norm_bases":["PB-04 edycja 9 z dnia 02.11.2023 r."],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość azotu ogólnego i węgla ogólnego\nZakres:\nN (4,0 – 50,0) g/kg\nC (320 – 600) g/kg\nMetoda wysokotemperaturowego spalania z detekcją TCD PB-04 edycja 9 z dnia 02.11.2023 r. Material roslinny Zawartosc azotu ogolnego i wegla ogolnego\nZakres:\nN (4,0 – 50,0) g/kg\nC (320 – 600) g/kg\nMetoda wysokotemperaturowego spalania z detekcja TCD PB-04 edycja 9 z dnia 02.11.2023 r.","categories":["materials"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen and total carbon content","parameters_en":[{"name":"N","range":"(4,0 – 50,0) g/kg"},{"name":"C","range":"(320 – 600) g/kg"}],"search_en":"Plant material Total nitrogen and total carbon content High-temperature combustion with TCD detection N C PB-04 edycja 9 z dnia 02.11.2023 r.","technique_en":"High-temperature combustion with TCD detection","test_object_en":"Plant material","search_zh":"植物材料 高温燃烧热导检测法（TCD） C PB-04 edycja 9 z dnia 02.11.2023 r.","test_object_zh":"植物材料","parameters_zh":[{"name":"N","range":"(4,0 – 50,0) g/kg"},{"name":"C","range":"(320 – 600) g/kg"}],"technique_zh":"高温燃烧热导检测法（TCD）"},{"_id":"6a83ad65af14b9c0e7b2018e","lab_id":"69ad52a3de79e566650fb3b6","country":"PL","accr_number":"AB 740","accr_body":"PCA","test_object":"Materiał roślinny","methodology":"Zawartość pierwiastków","parameters":[{"name":"Ca","range":"(0,7 – 18,0) g/kg"},{"name":"Mg","range":"(0,4 – 5,0) g/kg"},{"name":"K","range":"(1,5 – 20) g/kg"},{"name":"P","range":"(0,5 – 3,5) g/kg"},{"name":"S","range":"(0,6 – 7,5) g/kg"},{"name":"Na","range":"(30 – 20000) mg/kg"},{"name":"Mn","range":"(11 – 4500) mg/kg"},{"name":"Cu","range":"(0,8 – 22,0) mg/kg"},{"name":"Zn","range":"(7,0 – 350) mg/kg"},{"name":"Cd","range":"(0,1 – 2,0) mg/kg"},{"name":"Pb","range":"(1,0 – 32,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nCa (0,7 – 18,0) g/kg\nMg (0,4 – 5,0) g/kg\nK (1,5 – 20) g/kg\nP (0,5 – 3,5) g/kg\nS (0,6 – 7,5) g/kg\nNa (30 – 20000) mg/kg\nMn (11 – 4500) mg/kg\nCu (0,8 – 22,0) mg/kg\nZn (7,0 – 350) mg/kg\nCd (0,1 – 2,0) mg/kg\nPb (1,0 – 32,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PB-07 edycja 10 z dnia 02.11.2023 r.","norm_bases":["PB-07 edycja 10 z dnia 02.11.2023 r."],"lab_section":"Laboratorium Chemii Środowiska Przyrodniczego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiał roślinny Zawartość pierwiastków\nZakres:\nCa (0,7 – 18,0) g/kg\nMg (0,4 – 5,0) g/kg\nK (1,5 – 20) g/kg\nP (0,5 – 3,5) g/kg\nS (0,6 – 7,5) g/kg\nNa (30 – 20000) mg/kg\nMn (11 – 4500) mg/kg\nCu (0,8 – 22,0) mg/kg\nZn (7,0 – 350) mg/kg\nCd (0,1 – 2,0) mg/kg\nPb (1,0 – 32,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PB-07 edycja 10 z dnia 02.11.2023 r. Material roslinny Zawartosc pierwiastkow\nZakres:\nCa (0,7 – 18,0) g/kg\nMg (0,4 – 5,0) g/kg\nK (1,5 – 20) g/kg\nP (0,5 – 3,5) g/kg\nS (0,6 – 7,5) g/kg\nNa (30 – 20000) mg/kg\nMn (11 – 4500) mg/kg\nCu (0,8 – 22,0) mg/kg\nZn (7,0 – 350) mg/kg\nCd (0,1 – 2,0) mg/kg\nPb (1,0 – 32,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PB-07 edycja 10 z dnia 02.11.2023 r.","categories":["materials"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Ca","range":"(0,7 – 18,0) g/kg"},{"name":"Mg","range":"(0,4 – 5,0) g/kg"},{"name":"K","range":"(1,5 – 20) g/kg"},{"name":"P","range":"(0,5 – 3,5) g/kg"},{"name":"S","range":"(0,6 – 7,5) g/kg"},{"name":"Na","range":"(30 – 20000) mg/kg"},{"name":"Mn","range":"(11 – 4500) mg/kg"},{"name":"Cu","range":"(0,8 – 22,0) mg/kg"},{"name":"Zn","range":"(7,0 – 350) mg/kg"},{"name":"Cd","range":"(0,1 – 2,0) mg/kg"},{"name":"Pb","range":"(1,0 – 32,0) mg/kg"}],"search_en":"Plant material Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Ca Mg K P S Na Mn Cu Zn Cd Pb PB-07 edycja 10 z dnia 02.11.2023 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Plant material","methodology_zh":"元素含量","parameters_zh":[{"name":"Ca","range":"(0,7 – 18,0) g/kg"},{"name":"Mg","range":"(0,4 – 5,0) g/kg"},{"name":"K","range":"(1,5 – 20) g/kg"},{"name":"P","range":"(0,5 – 3,5) g/kg"},{"name":"S","range":"(0,6 – 7,5) g/kg"},{"name":"Na","range":"(30 – 20000) mg/kg"},{"name":"Mn","range":"(11 – 4500) mg/kg"},{"name":"Cu","range":"(0,8 – 22,0) mg/kg"},{"name":"Zn","range":"(7,0 – 350) mg/kg"},{"name":"Cd","range":"(0,1 – 2,0) mg/kg"},{"name":"Pb","range":"(1,0 – 32,0) mg/kg"}],"search_zh":"植物材料 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） Ca Mg K P S Na Mn Cu Zn Cd Pb PB-07 edycja 10 z dnia 02.11.2023 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"植物材料"}],"has_pdf":true}