{"lab":{"_id":"69ad52a3de79e566650fb3b0","accr_number":"AB 735","country":"PL","accr_body":"PCA","address":"- ODDZIAŁ ELEKTROWNIA RYBNIK, WYDZIAŁ LABORATORIUM CHEMICZNEGO, ul. Podmiejska","categories":["petro","water"],"city":"Rybnik","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"PGE GÓRNICTWO i ENERGETYKA KONWENCJONALNA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_735.pdf"],"scope_summary":"","search_text":"pge górnictwo i energetyka konwencjonalna s.a. - oddział elektrownia rybnik, wydział laboratorium chemicznego, ul. podmiejska petro other materials pharma environment water","status":"active","updated_at":"2026-03-08T14:51:37.623Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:21:52.290Z","needs_review":true,"review_reason":"brak e-maila — do znalezienia","email_confidence":"high","email_mx":true,"email_source":"https://elrybnik.pgegiek.pl/kontakt","fields_of_testing":[{"codes":"C/10; C28; C/32","pl":"Badania chemiczne paliw ciekłych, wody, odpadów","en":"Chemical tests of liquid fiuels, water, waste"},{"codes":"C/10/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek paliw stałych, ścieków","en":"Chemical tests and sampling of solid fuels, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties and sampling of water"},{"codes":"N/10/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek paliw stałych, ścieków","en":"Tests of physical properties and sampling of solid fuels, sewage"}],"issue":{"no":"27","date":"23.06.2026"},"parse_date":"2026-08-17T21:21:52.290Z","parse_source":"agent-claude-code","map_coord":[50.095579,18.541993],"map_geo":"nominatim-city","lab_locations":[{"name":"Wydział Laboratorium Chemicznego","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/20b310e7907763b9f80139f74be76498/AB%20735.pdf","has_en":true,"category_counts":{"petro":28,"water":15,"materials":2,"environment":1},"category_scores":{"petro":17.04,"water":4.89,"materials":0.09,"environment":0.02},"has_zh":true},"methods":[{"_id":"6a837b70af14b9c0e7b200de","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-G-04502:2014-11 p. 5.3.1.","norm_bases":["PN-G-04502:2014-11 p. 5.3.1."],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Pobieranie próbek do badań chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.1. Paliwa stale: wegiel kamienny Pobieranie probek do badan chemicznych i fizycznych PN-G-04502:2014-11 p. 5.3.1.","categories":["petro"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Solid fuels: hard coal Sampling for chemical and physical testing PN-G-04502:2014-11 p. 5.3.1.","test_object_en":"Solid fuels: hard coal","methodology_zh":"化学与物理检测用样品采集","search_zh":"固体燃料：烟煤 化学与物理检测用样品采集 PN-G-04502:2014-11 p. 5.3.1.","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200df","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)","parameters":[{"name":"Zakres","range":"(0,5 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (0,5 – 20,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 | PN-80/G-04511","norm_bases":["PN-ISO 589:2006","PN-80/G-04511"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nZakres (0,5 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej)\nZakres (0,5 – 20,0) %\nMetoda wagowa PN-ISO 589:2006 | PN-80/G-04511","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (free moisture)","parameters_en":[{"name":"Range","range":"(0,5 – 20,0) %"}],"search_en":"Solid fuels: hard coal First-stage moisture content (free moisture) Gravimetric method Range PN-ISO 589:2006 | PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,5 – 20,0) %"}],"search_zh":"固体燃料：烟煤 第一阶段水分（外在水分）含量 重量法 范围 PN-ISO 589:2006 | PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a837b70af14b9c0e7b200e0","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(1,0 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,0 – 30,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(1,0 – 30,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 30,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200e1","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-80/G-04511 | PN-ISO 589:2006","norm_bases":["PN-80/G-04511","PN-ISO 589:2006"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-80/G-04511 | PN-ISO 589:2006 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-80/G-04511 | PN-ISO 589:2006","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-80/G-04511 | PN-ISO 589:2006","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-80/G-04511 | PN-ISO 589:2006","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a837b70af14b9c0e7b200e2","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 10,0) %\nMetoda wagowa","reference":"PN-80/G-04511 | PN-ISO 11722:2009","norm_bases":["PN-80/G-04511","PN-ISO 11722:2009"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-80/G-04511 | PN-ISO 11722:2009 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-80/G-04511 | PN-ISO 11722:2009","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-80/G-04511 | PN-ISO 11722:2009","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-80/G-04511 | PN-ISO 11722:2009","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200e3","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w węglu powietrzno-suchym","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w węglu powietrzno-suchym\nZakres (0,5 – 10,0) %\nMetoda wagowa","reference":"PN-80/G-04511","norm_bases":["PN-80/G-04511"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w węglu powietrzno-suchym\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-80/G-04511 Paliwa stale: wegiel kamienny Zawartosc wilgoci w weglu powietrzno-suchym\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-80/G-04511","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in air-dried coal","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in air-dried coal Gravimetric method Range PN-80/G-04511","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) %"}],"search_zh":"固体燃料：烟煤 空气干燥煤中的水分含量 重量法 范围 PN-80/G-04511","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"空气干燥煤中的水分含量"},{"_id":"6a837b70af14b9c0e7b200e4","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,5 – 10,0) %\nMetoda wagowa","reference":"PN-ISO 589:2006 Metoda A1, A2","norm_bases":["PN-ISO 589:2006 Metoda A1, A2"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce)\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1, A2 Paliwa stale: wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci pozostalej w probce)\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-ISO 589:2006 Metoda A1, A2","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content (moisture remaining in the sample)","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) %"}],"search_en":"Solid fuels: hard coal Second-stage moisture content (moisture remaining in the sample) Gravimetric method Range PN-ISO 589:2006 Metoda A1, A2","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) %"}],"search_zh":"固体燃料：烟煤 第二阶段水分（样品残余水分）含量 重量法 范围 PN-ISO 589:2006 Metoda A1, A2","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"第二阶段水分（样品残余水分）含量"},{"_id":"6a837b70af14b9c0e7b200e5","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,0 – 40,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,0 – 40,0) %"}],"search_en":"Solid fuels: hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,0 – 40,0) %"}],"search_zh":"固体燃料：烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200e6","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(15,00 – 40,00) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość części lotnych\nZakres (15,00 – 40,00) %\nMetoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (15,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (15,00 – 40,00) %\nMetoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(15,00 – 40,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Gravimetric method Range PN-G-04516:1998","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(15,00 – 40,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 重量法 范围 PN-G-04516:1998","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a837b70af14b9c0e7b200e7","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,10 – 4,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,10 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001 | ISO 19579:2006","norm_bases":["PN-G-04584:2001","ISO 19579:2006"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość siarki całkowitej\nZakres (0,10 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 | ISO 19579:2006 Paliwa stale: wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,10 – 4,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001 | ISO 19579:2006","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,10 – 4,00) %"}],"search_en":"Solid fuels: hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001 | ISO 19579:2006","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,10 – 4,00) %"}],"search_zh":"固体燃料：烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001 | ISO 19579:2006","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200e8","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(5,0 – 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (5,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość węgla całkowitego\nZakres (5,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wegla calkowitego\nZakres (5,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(5,0 – 80,0) %"}],"search_en":"Solid fuels: hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(5,0 – 80,0) %"}],"search_zh":"固体燃料：烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200e9","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wodoru całkowitego","parameters":[{"name":"Zakres","range":"(3,00 – 6,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru całkowitego\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wodoru całkowitego\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: wegiel kamienny Zawartosc wodoru calkowitego\nZakres (3,00 – 6,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hydrogen content","parameters_en":[{"name":"Range","range":"(3,00 – 6,00) %"}],"search_en":"Solid fuels: hard coal Total hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(3,00 – 6,00) %"}],"search_zh":"固体燃料：烟煤 全氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料：烟煤","methodology_zh":"全氢含量"},{"_id":"6a837b70af14b9c0e7b200ea","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(10 000 – 35 000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (10 000 – 35 000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Ciepło spalania\nZakres (10 000 – 35 000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Cieplo spalania\nZakres (10 000 – 35 000) kJ/kg\nMetoda kalorymetryczna PN-81/G-04513 | PN-ISO 1928:2020-05","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(10 000 – 35 000) kJ/kg"}],"search_en":"Solid fuels: hard coal Gross calorific value Calorimetric method Range PN-81/G-04513 | PN-ISO 1928:2020-05","technique_en":"Calorimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(10 000 – 35 000) kJ/kg"}],"search_zh":"固体燃料：烟煤 高位发热量 量热法 范围 PN-81/G-04513 | PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200eb","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-81/G-04513 | PN-ISO 1928:2020-05","norm_bases":["PN-81/G-04513","PN-ISO 1928:2020-05"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Wartość opałowa (z obliczeń) PN-81/G-04513 | PN-ISO 1928:2020-05 Paliwa stale: wegiel kamienny Wartosc opalowa (z obliczen) PN-81/G-04513 | PN-ISO 1928:2020-05","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Solid fuels: hard coal Net calorific value (calculated) PN-81/G-04513 | PN-ISO 1928:2020-05","test_object_en":"Solid fuels: hard coal","methodology_zh":"低位发热量（计算值）","search_zh":"固体燃料：烟煤 低位发热量（计算值） PN-81/G-04513 | PN-ISO 1928:2020-05","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200ec","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,50 – 10,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 10,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,50 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,50 – 10,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,50 – 10,00) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,50 – 10,00) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200ed","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(2,00 – 40,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nZakres (2,00 – 40,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość popiołu\nZakres (2,00 – 40,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc popiolu\nZakres (2,00 – 40,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(2,00 – 40,00) %"}],"search_en":"Solid fuels: hard coal Ash content Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(2,00 – 40,00) %"}],"search_zh":"固体燃料：烟煤 灰分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200ee","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość części lotnych","parameters":[{"name":"Zakres","range":"(15,00 – 35,00) %"}],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość części lotnych\nZakres (15,00 – 35,00) %\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość części lotnych\nZakres (15,00 – 35,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: wegiel kamienny Zawartosc czesci lotnych\nZakres (15,00 – 35,00) %\nMetoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile matter content","parameters_en":[{"name":"Range","range":"(15,00 – 35,00) %"}],"search_en":"Solid fuels: hard coal Volatile matter content Thermogravimetric method (TGA) Range PN-G-04560:1998","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(15,00 – 35,00) %"}],"search_zh":"固体燃料：烟煤 挥发分含量 热重法（TGA） 范围 PN-G-04560:1998","technique_zh":"热重法（TGA）","test_object_zh":"固体燃料：烟煤","methodology_zh":"挥发分含量"},{"_id":"6a837b70af14b9c0e7b200ef","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci przemijającej","parameters":[{"name":"Zakres","range":"(1,5 – 20,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci przemijającej\nZakres (1,5 – 20,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci przemijającej\nZakres (1,5 – 20,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci przemijajacej\nZakres (1,5 – 20,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free moisture content","parameters_en":[{"name":"Range","range":"(1,5 – 20,0) %"}],"search_en":"Solid fuels: hard coal Free moisture content Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","parameters_zh":[{"name":"范围","range":"(1,5 – 20,0) %"}],"search_zh":"固体燃料：烟煤 外在水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤","methodology_zh":"外在水分含量"},{"_id":"6a837b70af14b9c0e7b200f0","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej","parameters":[{"name":"Zakres","range":"(2,5 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nZakres (2,5 – 30,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej\nZakres (2,5 – 30,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (2,5 – 30,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","parameters_en":[{"name":"Range","range":"(2,5 – 30,0) %"}],"search_en":"Solid fuels: hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(2,5 – 30,0) %"}],"search_zh":"固体燃料：烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200f1","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen) PN-G-04611:2020-06","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Solid fuels: hard coal Total moisture content (calculated) PN-G-04611:2020-06","test_object_en":"Solid fuels: hard coal","search_zh":"固体燃料：烟煤 全水分含量（计算值） PN-G-04611:2020-06","test_object_zh":"固体燃料：烟煤","methodology_zh":"全水分含量（计算值）"},{"_id":"6a837b70af14b9c0e7b200f2","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa stałe: węgiel kamienny","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 10,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe: węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale: wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 10,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) %"}],"search_en":"Solid fuels: hard coal Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06","technique_en":"Gravimetric method","test_object_en":"Solid fuels: hard coal","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) %"}],"search_zh":"固体燃料：烟煤 分析样品水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料：烟煤"},{"_id":"6a837b70af14b9c0e7b200f3","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Odpady: kod 10 01 01, 10 01 02","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(0,5 – 40,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (0,5 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":"Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady: kod 10 01 01, 10 01 02 Zawartość węgla całkowitego\nZakres (0,5 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady: kod 10 01 01, 10 01 02 Zawartosc wegla calkowitego\nZakres (0,5 – 40,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(0,5 – 40,0) %"}],"search_en":"Waste: code 10 01 01, 10 01 02 Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","technique_en":"High-temperature combustion with IR detection","test_object_en":"Waste: code 10 01 01, 10 01 02","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,5 – 40,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a837b70af14b9c0e7b200f4","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa ciekłe: ciężki olej opałowy","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,03 – 3,50) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość wody\nZakres (0,03 – 3,50) %\nMetoda miareczkowa","reference":"PB-15 wydanie 4 z dnia 30.10.2020 r.","norm_bases":["PB-15 wydanie 4 z dnia 30.10.2020 r."],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: ciężki olej opałowy Zawartość wody\nZakres (0,03 – 3,50) %\nMetoda miareczkowa PB-15 wydanie 4 z dnia 30.10.2020 r. Paliwa ciekle: ciezki olej opalowy Zawartosc wody\nZakres (0,03 – 3,50) %\nMetoda miareczkowa PB-15 wydanie 4 z dnia 30.10.2020 r.","categories":["petro","water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,03 – 3,50) %"}],"search_en":"Liquid fuels: heavy fuel oil Water content Titrimetric method Range PB-15 wydanie 4 z dnia 30.10.2020 r.","technique_en":"Titrimetric method","test_object_en":"Liquid fuels: heavy fuel oil","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,03 – 3,50) %"}],"search_zh":"液体燃料：重燃料油 水分含量 滴定法 范围 PB-15 wydanie 4 z dnia 30.10.2020 r.","technique_zh":"滴定法","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a837b70af14b9c0e7b200f5","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa ciekłe: ciężki olej opałowy","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,5 – 5,00) %"}],"technique":"Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","techniques":["Metoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,5 – 5,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF)","reference":"PN-EN ISO 8754:2026-02","norm_bases":["PN-EN ISO 8754:2026-02"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: ciężki olej opałowy Zawartość siarki całkowitej\nZakres (0,5 – 5,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersją energii (ED-XRF) PN-EN ISO 8754:2026-02 Paliwa ciekle: ciezki olej opalowy Zawartosc siarki calkowitej\nZakres (0,5 – 5,00) %\nMetoda fluorescencyjnej spektrometrii rentgenowskiej z dyspersja energii (ED-XRF) PN-EN ISO 8754:2026-02","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,5 – 5,00) %"}],"search_en":"Liquid fuels: heavy fuel oil Total sulfur content Energy-dispersive X-ray fluorescence spectrometry (ED-XRF) Range PN-EN ISO 8754:2026-02","technique_en":"Energy-dispersive X-ray fluorescence spectrometry (ED-XRF)","test_object_en":"Liquid fuels: heavy fuel oil","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,5 – 5,00) %"}],"search_zh":"液体燃料：重燃料油 全硫含量 能量色散X射线荧光光谱法（ED-XRF） 范围 PN-EN ISO 8754:2026-02","technique_zh":"能量色散X射线荧光光谱法（ED-XRF）","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a837b70af14b9c0e7b200f6","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa ciekłe: ciężki olej opałowy","methodology":"Zawartość siarki całkowitej","parameters":[{"name":"Zakres","range":"(0,5 – 5,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nZakres (0,5 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB-13 wydanie 4 z dnia 30.10.2020 r.","norm_bases":["PB-13 wydanie 4 z dnia 30.10.2020 r."],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: ciężki olej opałowy Zawartość siarki całkowitej\nZakres (0,5 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB-13 wydanie 4 z dnia 30.10.2020 r. Paliwa ciekle: ciezki olej opalowy Zawartosc siarki calkowitej\nZakres (0,5 – 5,00) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB-13 wydanie 4 z dnia 30.10.2020 r.","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","parameters_en":[{"name":"Range","range":"(0,5 – 5,00) %"}],"search_en":"Liquid fuels: heavy fuel oil Total sulfur content High-temperature combustion with IR detection Range PB-13 wydanie 4 z dnia 30.10.2020 r.","technique_en":"High-temperature combustion with IR detection","test_object_en":"Liquid fuels: heavy fuel oil","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,5 – 5,00) %"}],"search_zh":"液体燃料：重燃料油 全硫含量 高温燃烧红外检测法 范围 PB-13 wydanie 4 z dnia 30.10.2020 r.","technique_zh":"高温燃烧红外检测法","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a837b70af14b9c0e7b200f7","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa ciekłe: ciężki olej opałowy","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(8,0 – 15,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nZakres (8,0 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB-13 wydanie 4 z dnia 30.10.2020 r.","norm_bases":["PB-13 wydanie 4 z dnia 30.10.2020 r."],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: ciężki olej opałowy Zawartość wodoru\nZakres (8,0 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB-13 wydanie 4 z dnia 30.10.2020 r. Paliwa ciekle: ciezki olej opalowy Zawartosc wodoru\nZakres (8,0 – 15,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB-13 wydanie 4 z dnia 30.10.2020 r.","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(8,0 – 15,0) %"}],"search_en":"Liquid fuels: heavy fuel oil Hydrogen content High-temperature combustion with IR detection Range PB-13 wydanie 4 z dnia 30.10.2020 r.","technique_en":"High-temperature combustion with IR detection","test_object_en":"Liquid fuels: heavy fuel oil","parameters_zh":[{"name":"范围","range":"(8,0 – 15,0) %"}],"search_zh":"液体燃料：重燃料油 氢含量 高温燃烧红外检测法 范围 PB-13 wydanie 4 z dnia 30.10.2020 r.","technique_zh":"高温燃烧红外检测法","methodology_zh":"氢含量","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a837b70af14b9c0e7b200f8","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa ciekłe: ciężki olej opałowy","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(60,0 – 90,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (60,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PB-13 wydanie 4 z dnia 30.10.2020 r.","norm_bases":["PB-13 wydanie 4 z dnia 30.10.2020 r."],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: ciężki olej opałowy Zawartość węgla całkowitego\nZakres (60,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PB-13 wydanie 4 z dnia 30.10.2020 r. Paliwa ciekle: ciezki olej opalowy Zawartosc wegla calkowitego\nZakres (60,0 – 90,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PB-13 wydanie 4 z dnia 30.10.2020 r.","categories":["petro"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(60,0 – 90,0) %"}],"search_en":"Liquid fuels: heavy fuel oil Total carbon content High-temperature combustion with IR detection Range PB-13 wydanie 4 z dnia 30.10.2020 r.","technique_en":"High-temperature combustion with IR detection","test_object_en":"Liquid fuels: heavy fuel oil","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(60,0 – 90,0) %"}],"search_zh":"液体燃料：重燃料油 总碳含量 高温燃烧红外检测法 范围 PB-13 wydanie 4 z dnia 30.10.2020 r.","technique_zh":"高温燃烧红外检测法","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a837b70af14b9c0e7b200f9","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa ciekłe: ciężki olej opałowy","methodology":"Ciepło spalania","parameters":[{"name":"Zakres","range":"(38 000 – 48 000) kJ/kg"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nZakres (38 000 – 48 000) kJ/kg\nMetoda kalorymetryczna","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: ciężki olej opałowy Ciepło spalania\nZakres (38 000 – 48 000) kJ/kg\nMetoda kalorymetryczna PN-C-04062:2018-05 Paliwa ciekle: ciezki olej opalowy Cieplo spalania\nZakres (38 000 – 48 000) kJ/kg\nMetoda kalorymetryczna PN-C-04062:2018-05","categories":["petro"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","parameters_en":[{"name":"Range","range":"(38 000 – 48 000) kJ/kg"}],"search_en":"Liquid fuels: heavy fuel oil Gross calorific value Calorimetric method Range PN-C-04062:2018-05","technique_en":"Calorimetric method","test_object_en":"Liquid fuels: heavy fuel oil","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(38 000 – 48 000) kJ/kg"}],"search_zh":"液体燃料：重燃料油 高位发热量 量热法 范围 PN-C-04062:2018-05","technique_zh":"量热法","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a837b70af14b9c0e7b200fa","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Paliwa ciekłe: ciężki olej opałowy","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-C-04062:2018-05","norm_bases":["PN-C-04062:2018-05"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: ciężki olej opałowy Wartość opałowa (z obliczeń) PN-C-04062:2018-05 Paliwa ciekle: ciezki olej opalowy Wartosc opalowa (z obliczen) PN-C-04062:2018-05","categories":["petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Liquid fuels: heavy fuel oil Net calorific value (calculated) PN-C-04062:2018-05","test_object_en":"Liquid fuels: heavy fuel oil","methodology_zh":"低位发热量（计算值）","search_zh":"液体燃料：重燃料油 低位发热量（计算值） PN-C-04062:2018-05","test_object_zh":"液体燃料：重燃料油"},{"_id":"6a837b70af14b9c0e7b200fb","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pierwiastków","parameters":[{"name":"cynk","range":"(0,006 – 1,00) mg/l"},{"name":"miedź","range":"(0,005 – 1,00) mg/l"},{"name":"nikiel","range":"(0,004 – 1,00) mg/l"},{"name":"ołów","range":"(0,006 – 1,00) mg/l"},{"name":"kadm","range":"(0,0009 – 0,500) mg/l"},{"name":"chrom ogólny","range":"(0,003 – 1,00) mg/l"},{"name":"żelazo","range":"(0,004 – 50,0) mg/l"},{"name":"arsen","range":"(0,010 – 1,00) mg/l"},{"name":"bor","range":"(0,020 – 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\ncynk (0,006 – 1,00) mg/l\nmiedź (0,005 – 1,00) mg/l\nnikiel (0,004 – 1,00) mg/l\nołów (0,006 – 1,00) mg/l\nkadm (0,0009 – 0,500) mg/l\nchrom ogólny (0,003 – 1,00) mg/l\nżelazo (0,004 – 50,0) mg/l\narsen (0,010 – 1,00) mg/l\nbor (0,020 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pierwiastków\nZakres:\ncynk (0,006 – 1,00) mg/l\nmiedź (0,005 – 1,00) mg/l\nnikiel (0,004 – 1,00) mg/l\nołów (0,006 – 1,00) mg/l\nkadm (0,0009 – 0,500) mg/l\nchrom ogólny (0,003 – 1,00) mg/l\nżelazo (0,004 – 50,0) mg/l\narsen (0,010 – 1,00) mg/l\nbor (0,020 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie pierwiastkow\nZakres:\ncynk (0,006 – 1,00) mg/l\nmiedz (0,005 – 1,00) mg/l\nnikiel (0,004 – 1,00) mg/l\nolow (0,006 – 1,00) mg/l\nkadm (0,0009 – 0,500) mg/l\nchrom ogolny (0,003 – 1,00) mg/l\nzelazo (0,004 – 50,0) mg/l\narsen (0,010 – 1,00) mg/l\nbor (0,020 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"zinc","range":"(0,006 – 1,00) mg/l"},{"name":"copper","range":"(0,005 – 1,00) mg/l"},{"name":"nickel","range":"(0,004 – 1,00) mg/l"},{"name":"lead","range":"(0,006 – 1,00) mg/l"},{"name":"cadmium","range":"(0,0009 – 0,500) mg/l"},{"name":"total chromium","range":"(0,003 – 1,00) mg/l"},{"name":"iron","range":"(0,004 – 50,0) mg/l"},{"name":"arsenic","range":"(0,010 – 1,00) mg/l"},{"name":"boron","range":"(0,020 – 10,0) mg/l"}],"search_en":"Water Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) zinc copper nickel lead cadmium total chromium iron arsenic boron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","methodology_zh":"元素浓度","parameters_zh":[{"name":"锌","range":"(0,006 – 1,00) mg/l"},{"name":"铜","range":"(0,005 – 1,00) mg/l"},{"name":"镍","range":"(0,004 – 1,00) mg/l"},{"name":"铅","range":"(0,006 – 1,00) mg/l"},{"name":"镉","range":"(0,0009 – 0,500) mg/l"},{"name":"总铬","range":"(0,003 – 1,00) mg/l"},{"name":"铁","range":"(0,004 – 50,0) mg/l"},{"name":"砷","range":"(0,010 – 1,00) mg/l"},{"name":"硼","range":"(0,020 – 10,0) mg/l"}],"search_zh":"水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 锌 铜 镍 铅 镉 总铬 铁 砷 硼 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水"},{"_id":"6a837b70af14b9c0e7b200fc","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a837b70af14b9c0e7b200fd","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(2,0 – 40,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (2,0 – 40,0) °C","reference":"PN/77/C-04584","norm_bases":["PN/77/C-04584"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (2,0 – 40,0) °C PN/77/C-04584 Scieki Temperatura\nZakres (2,0 – 40,0) °C PN/77/C-04584","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(2,0 – 40,0) °C"}],"search_en":"Wastewater Temperature Range PN/77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 40,0) °C"}],"search_zh":"污水 温度 范围 PN/77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a837b70af14b9c0e7b200fe","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie arsenu","parameters":[{"name":"Zakres","range":"(0,010 – 1,00) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej w plazmie indukcyjnie sprzężonej z techniką generowania wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej w plazmie indukcyjnie sprzężonej z techniką generowania wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie arsenu\nZakres (0,010 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej w plazmie indukcyjnie sprzężonej z techniką generowania wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie arsenu\nZakres (0,010 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej w plazmie indukcyjnie sprzężonej z techniką generowania wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie arsenu\nZakres (0,010 – 1,00) mg/l\nMetoda emisyjnej spektrometrii atomowej w plazmie indukcyjnie sprzezonej z technika generowania wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Arsenic concentration","parameters_en":[{"name":"Range","range":"(0,010 – 1,00) mg/l"}],"search_en":"Wastewater Arsenic concentration Inductively coupled plasma atomic emission spectrometry with the hydride generation technique (HG-ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma atomic emission spectrometry with the hydride generation technique (HG-ICP-OES)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 1,00) mg/l"}],"search_zh":"污水 砷浓度 范围 PN-EN ISO 11885:2009","test_object_zh":"污水","methodology_zh":"砷浓度"},{"_id":"6a837b70af14b9c0e7b200ff","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"cynk","range":"(0,050 – 50,0) mg/l"},{"name":"miedź","range":"(0,010 – 1,00) mg/l"},{"name":"nikiel","range":"(0,010 – 1,00) mg/l"},{"name":"ołów","range":"(0,010 – 50,0) mg/l"},{"name":"kadm","range":"(0,0012 – 1,00) mg/l"},{"name":"chrom ogólny","range":"(0,002 – 1,00) mg/l"},{"name":"żelazo","range":"(0,030 – 500) mg/l"},{"name":"bor","range":"(0,16 – 200) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\ncynk (0,050 – 50,0) mg/l\nmiedź (0,010 – 1,00) mg/l\nnikiel (0,010 – 1,00) mg/l\nołów (0,010 – 50,0) mg/l\nkadm (0,0012 – 1,00) mg/l\nchrom ogólny (0,002 – 1,00) mg/l\nżelazo (0,030 – 500) mg/l\nbor (0,16 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\ncynk (0,050 – 50,0) mg/l\nmiedź (0,010 – 1,00) mg/l\nnikiel (0,010 – 1,00) mg/l\nołów (0,010 – 50,0) mg/l\nkadm (0,0012 – 1,00) mg/l\nchrom ogólny (0,002 – 1,00) mg/l\nżelazo (0,030 – 500) mg/l\nbor (0,16 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\ncynk (0,050 – 50,0) mg/l\nmiedz (0,010 – 1,00) mg/l\nnikiel (0,010 – 1,00) mg/l\nolow (0,010 – 50,0) mg/l\nkadm (0,0012 – 1,00) mg/l\nchrom ogolny (0,002 – 1,00) mg/l\nzelazo (0,030 – 500) mg/l\nbor (0,16 – 200) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"zinc","range":"(0,050 – 50,0) mg/l"},{"name":"copper","range":"(0,010 – 1,00) mg/l"},{"name":"nickel","range":"(0,010 – 1,00) mg/l"},{"name":"lead","range":"(0,010 – 50,0) mg/l"},{"name":"cadmium","range":"(0,0012 – 1,00) mg/l"},{"name":"total chromium","range":"(0,002 – 1,00) mg/l"},{"name":"iron","range":"(0,030 – 500) mg/l"},{"name":"boron","range":"(0,16 – 200) mg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) zinc copper nickel lead cadmium total chromium iron boron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"锌","range":"(0,050 – 50,0) mg/l"},{"name":"铜","range":"(0,010 – 1,00) mg/l"},{"name":"镍","range":"(0,010 – 1,00) mg/l"},{"name":"铅","range":"(0,010 – 50,0) mg/l"},{"name":"镉","range":"(0,0012 – 1,00) mg/l"},{"name":"总铬","range":"(0,002 – 1,00) mg/l"},{"name":"铁","range":"(0,030 – 500) mg/l"},{"name":"硼","range":"(0,16 – 200) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 锌 铜 镍 铅 镉 总铬 铁 硼 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水"},{"_id":"6a837b70af14b9c0e7b20100","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00005 – 0,5) mg/l"},{"name":"Zakres","range":"(0,05 – 500) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres:\nZakres (0,00005 – 0,5) mg/l\nZakres (0,05 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres:\nZakres (0,00005 – 0,5) mg/l\nZakres (0,05 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07 Woda, scieki Stezenie rteci\nZakres:\nZakres (0,00005 – 0,5) mg/l\nZakres (0,05 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00005 – 0,5) mg/l"},{"name":"Range","range":"(0,05 – 500) µg/l"}],"search_en":"Water, wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range Range PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00005 – 0,5) mg/l"},{"name":"范围","range":"(0,05 – 500) µg/l"}],"search_zh":"水、废水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 范围 PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、废水"},{"_id":"6a837b70af14b9c0e7b20101","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00010 – 0,5) mg/l"},{"name":"Zakres","range":"(0,10 – 500) µg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres:\nZakres (0,00010 – 0,5) mg/l\nZakres (0,10 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PN-EN ISO 12846:2012 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 +Ap1:2016-07"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres:\nZakres (0,00010 – 0,5) mg/l\nZakres (0,10 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PN-EN ISO 12846:2012 +Ap1:2016-07 Woda, scieki Stezenie rteci\nZakres:\nZakres (0,00010 – 0,5) mg/l\nZakres (0,10 – 500) µg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PN-EN ISO 12846:2012 +Ap1:2016-07","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00010 – 0,5) mg/l"},{"name":"Range","range":"(0,10 – 500) µg/l"}],"search_en":"Water, wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range Range PN-EN ISO 12846:2012 +Ap1:2016-07","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00010 – 0,5) mg/l"},{"name":"范围","range":"(0,10 – 500) µg/l"}],"search_zh":"水、废水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 范围 PN-EN ISO 12846:2012 +Ap1:2016-07","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、废水"},{"_id":"6a837b70af14b9c0e7b20102","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a837b70af14b9c0e7b20103","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,00 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,00 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,00 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,00 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,00 – 10000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,00 – 10000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a837b70af14b9c0e7b20104","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2,00 – 30000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (2,00 – 30000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (2,00 – 30000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (2,00 – 30000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2,00 – 30000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2,00 – 30000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a837b70af14b9c0e7b20105","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10,0 – 2000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10,0 – 2000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 2000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 2000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a837b70af14b9c0e7b20106","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(15,0 – 300) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15,0 – 300) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15,0 – 300) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15,0 – 300) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(15,0 – 300) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(15,0 – 300) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a837b70af14b9c0e7b20107","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3,0 – 100,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 100,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 100,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 100,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3,0 – 100,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3,0 – 100,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a837b70af14b9c0e7b20108","lab_id":"69ad52a3de79e566650fb3b0","country":"PL","accr_number":"AB 735","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Wydział Laboratorium Chemicznego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"}],"has_pdf":true}