{"lab":{"_id":"69ad52a3de79e566650fb3ae","accr_number":"AB 733","country":"PL","accr_body":"PCA","address":"im. Jarosława Dąbrowskiego, WYDZIAŁ INŻYNIERII MECHANICZNEJ, LABORATORIUM POJAZDÓW MECHANICZNYCH, ul. gen. Sylwestra Kaliskiego 2","categories":["petro","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":4,"name":"WOJSKOWA AKADEMIA TECHNICZNA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_733.pdf"],"scope_summary":"","search_text":"wojskowa akademia techniczna im. jarosława dąbrowskiego, wydział inżynierii mechanicznej, laboratorium pojazdów mechanicznych, ul. gen. sylwestra kaliskiego 2 metrology other petro food pharma automotive","status":"active","updated_at":"2026-03-08T14:51:37.547Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:22:00.116Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20733,podmiot.html","fields_of_testing":[{"codes":"N/10; N/46","pl":"Badania właściwości fizycznych: paliwa, materiały smarne","en":"Tests of physical properties: fuels, lubricants"},{"codes":"G/5","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne): wyroby budowlane, materiały budowlane, obiekty budowlane","en":"Tests concerning environmental engineering (environmental and climatic): building products, materials and items"}],"issue":{"no":"20","date":"09.06.2026"},"parse_date":"2026-08-17T21:22:00.116Z","parse_source":"agent-claude-code","map_coord":[52.250046,20.901794],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM POJAZDÓW MECHANICZNYCH","address":"ul. gen. Sylwestra Kaliskiego 2","city":null,"postal":null},{"name":"Stacja Badań Klimatycznych i Silników Spalinowych","address":"ul. gen. Sylwestra Kaliskiego 2","city":"Warszawa","postal":"00-908"},{"name":"Stacja Badań Płynów Eksploatacyjnych","address":"ul. gen. Sylwestra Kaliskiego 2","city":"Warszawa","postal":"00-908"}],"scope_format":"PCA::pracownie+siatka6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/4b52a428564897dfa0e4d9a4b468a362/AB%20733.pdf","has_en":true,"category_counts":{"petro":2,"other":2,"materials":1},"category_scores":{"petro":0.8,"other":0.8,"materials":0.2},"has_zh":true},"methods":[{"_id":"6a837b78af14b9c0e7b2011a","lab_id":"69ad52a3de79e566650fb3ae","country":"PL","accr_number":"AB 733","accr_body":"PCA","test_object":"Pomieszczenia biurowe, magazynowe, mieszkalne, usługowe","methodology":"Rozkład temperatury:","parameters":[{"name":"Zakres pomiarowy","range":"(-45 ÷ +80)°C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Rozkład temperatury:\nZakres pomiarowy (-45 ÷ +80)°C\nMetoda pomiarowa bezpośrednia","reference":"LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","norm_bases":["LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r."],"lab_section":"Stacja Badań Klimatycznych i Silników Spalinowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia biurowe, magazynowe, mieszkalne, usługowe Rozkład temperatury:\nZakres pomiarowy (-45 ÷ +80)°C\nMetoda pomiarowa bezpośrednia LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r. Pomieszczenia biurowe, magazynowe, mieszkalne, uslugowe Rozklad temperatury:\nZakres pomiarowy (-45 ÷ +80)°C\nMetoda pomiarowa bezposrednia LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature distribution:","parameters_en":[{"name":"Measuring range","range":"(-45 ÷ +80)°C"}],"search_en":"Office, storage, residential and service rooms Temperature distribution: Direct measurement method Measuring range LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","technique_en":"Direct measurement method","test_object_en":"Office, storage, residential and service rooms","search_zh":"直接测量法 测量范围 LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","technique_zh":"直接测量法","parameters_zh":[{"name":"测量范围","range":"(-45 ÷ +80)°C"}]},{"_id":"6a837b78af14b9c0e7b2011b","lab_id":"69ad52a3de79e566650fb3ae","country":"PL","accr_number":"AB 733","accr_body":"PCA","test_object":"Komory klimatyczne","methodology":"Rozkład temperatury:","parameters":[{"name":"Zakres pomiarowy","range":"(-45 ÷ +5)°C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Rozkład temperatury:\nZakres pomiarowy (-45 ÷ +5)°C\nMetoda pomiarowa bezpośrednia","reference":"LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","norm_bases":["LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r."],"lab_section":"Stacja Badań Klimatycznych i Silników Spalinowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Komory klimatyczne Rozkład temperatury:\nZakres pomiarowy (-45 ÷ +5)°C\nMetoda pomiarowa bezpośrednia LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r. Komory klimatyczne Rozklad temperatury:\nZakres pomiarowy (-45 ÷ +5)°C\nMetoda pomiarowa bezposrednia LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature distribution:","parameters_en":[{"name":"Measuring range","range":"(-45 ÷ +5)°C"}],"search_en":"Climatic chambers Temperature distribution: Direct measurement method Measuring range LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","technique_en":"Direct measurement method","test_object_en":"Climatic chambers","search_zh":"直接测量法 测量范围 LPM/PS-SBKSS-3 Wersja 2 z dnia 15.03.2019 r.","technique_zh":"直接测量法","parameters_zh":[{"name":"测量范围","range":"(-45 ÷ +5)°C"}]},{"_id":"6a837b78af14b9c0e7b2011c","lab_id":"69ad52a3de79e566650fb3ae","country":"PL","accr_number":"AB 733","accr_body":"PCA","test_object":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME); Materiały smarne: oleje smarne","methodology":"Temperatura mętnienia","parameters":[{"name":"Zakres pomiarowy","range":"(-40 ÷ +10)°C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura mętnienia\nZakres pomiarowy (-40 ÷ +10)°C\nMetoda optyczna","reference":"PN-ISO 3015:2019-06","norm_bases":["PN-ISO 3015:2019-06"],"lab_section":"Stacja Badań Płynów Eksploatacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe: olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME); Materiały smarne: oleje smarne Temperatura mętnienia\nZakres pomiarowy (-40 ÷ +10)°C\nMetoda optyczna PN-ISO 3015:2019-06 Paliwa ciekle: olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME); Materialy smarne: oleje smarne Temperatura metnienia\nZakres pomiarowy (-40 ÷ +10)°C\nMetoda optyczna PN-ISO 3015:2019-06","categories":["petro","materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cloud point","parameters_en":[{"name":"Measuring range","range":"(-40 ÷ +10)°C"}],"search_en":"Cloud point Optical method Measuring range PN-ISO 3015:2019-06","technique_en":"Optical method","search_zh":"浊点 光学法 测量范围 PN-ISO 3015:2019-06","technique_zh":"光学法","parameters_zh":[{"name":"测量范围","range":"(-40 ÷ +10)°C"}],"methodology_zh":"浊点"},{"_id":"6a837b78af14b9c0e7b2011d","lab_id":"69ad52a3de79e566650fb3ae","country":"PL","accr_number":"AB 733","accr_body":"PCA","test_object":"Paliwa ciekłe – olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME)","methodology":"Temperatura zablokowania zimnego filtru (CFPP)","parameters":[{"name":"Zakres pomiarowy","range":"(–45 ÷ +15)°C"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Temperatura zablokowania zimnego filtru (CFPP)\nZakres pomiarowy (–45 ÷ +15)°C\nMetoda optyczna","reference":"PN-EN 116:2015-09","norm_bases":["PN-EN 116:2015-09"],"lab_section":"Stacja Badań Płynów Eksploatacyjnych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa ciekłe – olej napędowy, olej opałowy lekki, biopaliwa ciekłe: olej napędowy z FAME, estry metylowe kwasów tłuszczowych (FAME) Temperatura zablokowania zimnego filtru (CFPP)\nZakres pomiarowy (–45 ÷ +15)°C\nMetoda optyczna PN-EN 116:2015-09 Paliwa ciekle – olej napedowy, olej opalowy lekki, biopaliwa ciekle: olej napedowy z FAME, estry metylowe kwasow tluszczowych (FAME) Temperatura zablokowania zimnego filtru (CFPP)\nZakres pomiarowy (–45 ÷ +15)°C\nMetoda optyczna PN-EN 116:2015-09","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cold filter plugging point (CFPP)","parameters_en":[{"name":"Measuring range","range":"(–45 ÷ +15)°C"}],"search_en":"Liquid fuels – diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME) Cold filter plugging point (CFPP) Optical method Measuring range PN-EN 116:2015-09","technique_en":"Optical method","test_object_en":"Liquid fuels – diesel fuel, light fuel oil, liquid biofuels: diesel fuel with FAME, fatty acid methyl esters (FAME)","search_zh":"冷滤点（CFPP） 光学法 测量范围 PN-EN 116:2015-09","technique_zh":"光学法","parameters_zh":[{"name":"测量范围","range":"(–45 ÷ +15)°C"}],"methodology_zh":"冷滤点（CFPP）"}],"has_pdf":true}