{"lab":{"_id":"69ad52a3de79e566650fb3aa","accr_number":"AB 727","country":"PL","accr_body":"PCA","address":"Spółka z o.o., ul. Ks. B. Jaśkowskiego 14, 88-100 Inowrocław, Laboratorium","categories":["water","microbiology"],"city":"Inowrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":33,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_727.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji spółka z o.o., ul. ks. b. jaśkowskiego 14, 88-100 inowrocław, laboratorium water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:37.378Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:21:45.893Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20727,podmiot.html","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Physical properties of water"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, driniking water"}],"issue":{"no":"19","date":"26.05.2026"},"parse_date":"2026-08-17T21:21:45.893Z","parse_source":"agent-claude-code","map_coord":[52.795241,18.259562],"map_geo":"nominatim-city","lab_locations":[{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/3eff42673f3d1cff43fdf069ab8dd63f/AB%20727.pdf","has_en":true,"category_counts":{"water":33,"microbiology":3},"category_scores":{"water":30.25,"microbiology":0.25},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a837b69af14b9c0e7b200b3","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi, woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption, water Sampling for chemical and physical testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水、水 化学与物理检测用样品采集 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200b4","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 9,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda pH\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, woda pH\nZakres 2,0 – 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 9,0"}],"search_en":"Water intended for human consumption, water pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 9,0"}],"search_zh":"生活饮用水、水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200b5","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(50 - 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (50 - 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Przewodność elektryczna właściwa\nZakres (50 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi, woda Przewodnosc elektryczna wlasciwa\nZakres (50 - 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(50 - 2500) μS/cm"}],"search_en":"Water intended for human consumption, water Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50 - 2500) μS/cm"}],"search_zh":"生活饮用水、水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200b6","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi, woda Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 100) NTU"}],"search_en":"Water intended for human consumption, water Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 100) NTU"}],"search_zh":"生活饮用水、水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200b7","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,016 - 0,82) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,016 - 0,82) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie azotynów\nZakres (0,016 - 0,82) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi, woda Stezenie azotynow\nZakres (0,016 - 0,82) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,016 - 0,82) mg/l"}],"search_en":"Water intended for human consumption, water Nitrite concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,016 - 0,82) mg/l"}],"search_zh":"生活饮用水、水 亚硝酸盐浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200b8","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,44 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,44 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie azotanów\nZakres (0,44 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda do spozycia przez ludzi, woda Stezenie azotanow\nZakres (0,44 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,44 – 50,0) mg/l"}],"search_en":"Water intended for human consumption, water Nitrate concentration Spectrophotometric method Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 – 50,0) mg/l"}],"search_zh":"生活饮用水、水 硝酸盐浓度 分光光度法 实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200b9","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,050 - 1,29) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,050 - 1,29) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie jonu amonowego\nZakres (0,050 - 1,29) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi, woda Stezenie jonu amonowego\nZakres (0,050 - 1,29) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,050 - 1,29) mg/l"}],"search_en":"Water intended for human consumption, water Ammonium ion concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,050 - 1,29) mg/l"}],"search_zh":"生活饮用水、水 铵离子浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200ba","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 - 800) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 800) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 800) mg/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi, woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 - 800) mg/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 - 800) mg/l"}],"search_en":"Water intended for human consumption, water Total content of calcium and magnesium (total hardness) Titrimetric method Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 - 800) mg/l"}],"search_zh":"生活饮用水、水 钙与镁总量（总硬度） 滴定法 实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200bb","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,020 - 10,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,020 - 10,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie żelaza\nZakres (0,020 - 10,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi, woda Stezenie zelaza\nZakres (0,020 - 10,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,020 - 10,00) mg/l"}],"search_en":"Water intended for human consumption, water Iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 10,00) mg/l"}],"search_zh":"生活饮用水、水 铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200bc","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi, woda Stezenie chlorkow\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 - 400) mg/l"}],"search_en":"Water intended for human consumption, water Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 400) mg/l"}],"search_zh":"生活饮用水、水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200bd","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 - 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 - 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/TL-06 wydanie 04 z dnia 29.01.2020 r. | na podstawie testu Spectroquant Merck 1.14770.0001","norm_bases":["PB/TL-06 wydanie 04 z dnia 29.01.2020 r.","na podstawie testu Spectroquant Merck 1.14770.0001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Stężenie manganu\nZakres (0,010 - 2,0) mg/l\nMetoda spektrofotometryczna PB/TL-06 wydanie 04 z dnia 29.01.2020 r. | na podstawie testu Spectroquant Merck 1.14770.0001 Woda do spozycia przez ludzi, woda Stezenie manganu\nZakres (0,010 - 2,0) mg/l\nMetoda spektrofotometryczna PB/TL-06 wydanie 04 z dnia 29.01.2020 r. | na podstawie testu Spectroquant Merck 1.14770.0001","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 - 2,0) mg/l"}],"search_en":"Water intended for human consumption, water Manganese concentration Spectrophotometric method Laboratory Range PB/TL-06 wydanie 04 z dnia 29.01.2020 r. | na podstawie testu Spectroquant Merck 1.14770.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 - 2,0) mg/l"}],"search_zh":"生活饮用水、水 锰浓度 分光光度法 实验室 范围 PB/TL-06 wydanie 04 z dnia 29.01.2020 r. | na podstawie testu Spectroquant Merck 1.14770.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200be","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200bf","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (5,0 – 50,0) °C PN-77/C-04584 Scieki Temperatura\nZakres (5,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5,0 – 50,0) °C"}],"search_en":"Wastewater Temperature Laboratory Range PN-77/C-04584","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5,0 – 50,0) °C"}],"search_zh":"污水 温度 实验室 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a837b69af14b9c0e7b200c0","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 9,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 2,0 - 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 2,0 - 9,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 9,0"}],"search_en":"Wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 9,0"}],"search_zh":"污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200c1","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 - 4000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 - 4000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5 - 4000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5 - 4000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 - 4000) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 4000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200c2","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu","parameters":[{"name":"Zakres","range":"(0,040 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu\nZakres (0,040 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu\nZakres (0,040 – 30,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu\nZakres (0,040 – 30,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,040 – 30,0) mg/l"}],"search_en":"Wastewater Phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,040 – 30,0) mg/l"}],"search_zh":"污水 磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"磷浓度"},{"_id":"6a837b69af14b9c0e7b200c3","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,040 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,040 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,040 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,040 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,040 – 10,0) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 10,0) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200c4","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(10,0 - 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (10,0 - 150) mg/l\nMetoda spektrofotometryczna","reference":"PB/TL-12 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.00683.0001","norm_bases":["PB/TL-12 wydanie 04 z dnia 12.03.2024 r.","na podstawie testu Spectroquant Merck 1.00683.0001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (10,0 - 150) mg/l\nMetoda spektrofotometryczna PB/TL-12 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.00683.0001 Scieki Stezenie azotu amonowego\nZakres (10,0 - 150) mg/l\nMetoda spektrofotometryczna PB/TL-12 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.00683.0001","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(10,0 - 150) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PB/TL-12 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.00683.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(10,0 - 150) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 实验室 范围 PB/TL-12 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.00683.0001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200c5","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200c6","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(20 - 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (20 - 150) mg/l\nMetoda spektrofotometryczna","reference":"PB/TL-20 wydanie 03 z dnia 04.02.2020 r. | na podstawie testu Spectroquant Merck 1.14763.0001","norm_bases":["PB/TL-20 wydanie 03 z dnia 04.02.2020 r.","na podstawie testu Spectroquant Merck 1.14763.0001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (20 - 150) mg/l\nMetoda spektrofotometryczna PB/TL-20 wydanie 03 z dnia 04.02.2020 r. | na podstawie testu Spectroquant Merck 1.14763.0001 Scieki Stezenie azotu ogolnego\nZakres (20 - 150) mg/l\nMetoda spektrofotometryczna PB/TL-20 wydanie 03 z dnia 04.02.2020 r. | na podstawie testu Spectroquant Merck 1.14763.0001","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(20 - 150) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range PB/TL-20 wydanie 03 z dnia 04.02.2020 r. | na podstawie testu Spectroquant Merck 1.14763.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(20 - 150) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 实验室 范围 PB/TL-20 wydanie 03 z dnia 04.02.2020 r. | na podstawie testu Spectroquant Merck 1.14763.0001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200c7","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/TL-26 wydanie 03 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.14 537.0001","norm_bases":["PB/TL-26 wydanie 03 z dnia 12.03.2024 r.","na podstawie testu Spectroquant Merck 1.14 537.0001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PB/TL-26 wydanie 03 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.14 537.0001 Scieki Stezenie azotu ogolnego\nZakres (1,0 – 15,0) mg/l\nMetoda spektrofotometryczna PB/TL-26 wydanie 03 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.14 537.0001","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 15,0) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range PB/TL-26 wydanie 03 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.14 537.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 实验室 范围 PB/TL-26 wydanie 03 z dnia 12.03.2024 r. | na podstawie testu Spectroquant Merck 1.14 537.0001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200c8","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(3,0 - 300) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (3,0 - 300) mg/l\nMetoda spektrofotometryczna","reference":"PB/TL-29 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu kuwetowego HACH LANGE LCK 385","norm_bases":["PB/TL-29 wydanie 04 z dnia 12.03.2024 r.","na podstawie testu kuwetowego HACH LANGE LCK 385"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (3,0 - 300) mg/l\nMetoda spektrofotometryczna PB/TL-29 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu kuwetowego HACH LANGE LCK 385 Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (3,0 - 300) mg/l\nMetoda spektrofotometryczna PB/TL-29 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu kuwetowego HACH LANGE LCK 385","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(3,0 - 300) mg/l"}],"search_en":"Wastewater Total organic carbon concentration (TOC) Spectrophotometric method Laboratory Range PB/TL-29 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu kuwetowego HACH LANGE LCK 385","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(3,0 - 300) mg/l"}],"search_zh":"污水 总有机碳浓度（TOC） 分光光度法 实验室 范围 PB/TL-29 wydanie 04 z dnia 12.03.2024 r. | na podstawie testu kuwetowego HACH LANGE LCK 385","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a837b69af14b9c0e7b200c9","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","parameters":[{"name":"Zakres","range":"(0,5 - 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN1899-2:2002","norm_bases":["PN-EN1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN1899-2:2002","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand (BOD5)","parameters_en":[{"name":"Range","range":"(0,5 - 6,0) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand (BOD5) Electrochemical method Laboratory Range PN-EN1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 - 6,0) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a837b69af14b9c0e7b200ca","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","parameters":[{"name":"Zakres","range":"(3 - 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand (BOD5)","parameters_en":[{"name":"Range","range":"(3 - 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand (BOD5) Electrochemical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(3 - 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a837b69af14b9c0e7b200cb","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(30 - 1500) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (30 - 1500) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (30 - 1500) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (30 - 1500) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(30 - 1500) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand (COD-Cr) Titrimetric method Laboratory Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(30 - 1500) mg/l O2"}],"search_zh":"污水 化学需氧量（ChZT-Cr / CODCr） 滴定法 实验室 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200cc","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(10 - 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 - 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005 zał. C","norm_bases":["PN-ISO 15705:2005 zał. C"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 - 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 zał. C Scieki Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10 - 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 zal. C","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(10 - 150) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand (COD-Cr) Spectrophotometric method Laboratory Range PN-ISO 15705:2005 zał. C","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(10 - 150) mg/l O2"}],"search_zh":"污水 化学需氧量（ChZT-Cr / CODCr） 分光光度法 实验室 范围 PN-ISO 15705:2005 zał. C","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200cd","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 - 1000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 - 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a837b69af14b9c0e7b200ce","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6 Woda do spozycia przez ludzi, woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6","categories":["water","microbiology"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption, water Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水、水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.3; 4.4.4; 4.4.5; 4.4.6","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200cf","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Ogólna liczba mikroorganizmów w 360C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 360C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Ogólna liczba mikroorganizmów w 360C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, woda Ogolna liczba mikroorganizmow w 360C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total microorganism count at 360C","search_en":"Water intended for human consumption, water Total microorganism count at 360C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","search_zh":"生活饮用水、水 36°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水、水","methodology_zh":"36°C 微生物总数"},{"_id":"6a837b69af14b9c0e7b200d0","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Ogólna liczba mikroorganizmów w 220C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 220C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Ogólna liczba mikroorganizmów w 220C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, woda Ogolna liczba mikroorganizmow w 220C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total microorganism count at 220C","search_en":"Water intended for human consumption, water Total microorganism count at 220C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","search_zh":"生活饮用水、水 22°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水、水","methodology_zh":"22°C 微生物总数"},{"_id":"6a837b69af14b9c0e7b200d1","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Liczba Escherichia coli\nMetoda filtracji membranowej PN EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, woda Liczba Escherichia coli\nMetoda filtracji membranowej PN EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption, water Escherichia coli count Membrane filtration method Laboratory PN EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水、水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室 PN EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200d2","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption, water Coliform bacteria count Membrane filtration method Laboratory PN EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水、水 大肠菌群计数 膜过滤法 实验室 PN EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水"},{"_id":"6a837b69af14b9c0e7b200d3","lab_id":"69ad52a3de79e566650fb3aa","country":"PL","accr_number":"AB 727","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi, woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption, water Intestinal enterococci count Membrane filtration method Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, water","lab_section_zh":"实验室","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水、水 粪肠球菌计数 膜过滤法 实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水"}],"has_pdf":true}